Large Area Telescope

End Item Data Package (EIDP)

Requirements Verification Test Flow

The following diagram illustrates the test flow for all LAT performance, calibration, functional, and environmental tests conducted at NRL. Click on any test occurrence in the figure to link to the test procedures, test reports, test logs, and requirements sell-off packages associated with that test.

LAT-Level Test Documents


LAT Level Test Procedures

The steps for execution of the Limited Performance Tests, Comprehensive Performance Tests, LAT Functional and FSW Test, and TCS Functional Test during the various phases of LAT-level testing at NRL are described in the LAT-PS-07836: LAT Test Procedure with LICOS. This document describes how the LICOS system is used to execute the test cases defined in LAT-MD-02730: LAT Performance & Operations Test Plan.

The test procedure for Sine Vibe testing is presented in LAT-PS-08112 GLAST LAT Protoflight Sine Vibration Test Procedure.

The test program for EMI/EMC testing is presented in LAT-MD-02726 LAT EMI/EMC Test Plan.

The test procedure for Acoustic testing is presented in LAT-PS-08113 GLAST LAT Protoflight Acoustic Vibration Test Procedure.

The test procedure for Thermal Vac testing is presented in LAT-TD-06799 LAT Thermal Vacuum Test Procedure.

The test procedure for Mass Properties/Weight CG testing is presented in LAT-TD-08114 GLAST LAT Mass Properties Test Procedure.


Performance and Operations Test Reports, Test Logs, and Requirements Sell-off Packages

The following sections present the run records and links to test reports, test logs, and sell-off packages corresponding to the test activities defined in the , as illustrated in the figure above. For convenience, these records are split and presented by test type (comprehensive performance tes, limited performance test, etc.). The full record of the test flow starting with the Post-Ship CPT is presented in this spreadsheet. The full record of the test flow starting with Thermal Vac testing is presented in this spreadsheet.


Comprehensive Performance Test Results

As shown in the flow diagram above, Comprehensive Performance Tests are executed in several phases of the LAT-level test program. Outputs of all tests in the sequence are stored in the E-Log database developed and maintained by the LAT Integration and Test Team.

In this section, the CPTs are itemized and each is linked to a spreadsheet listing the test cases executed as part of that test and the associated E-Log run identifiers (RunIDs). Enter the RunID in the Run Range field of the E-Log query page to retrieve the test logs and raw test data associated with each execution.

NRL Post-Ship CPT

NRL Pre-Thermal Vac CPT

Hot Protoflight CPT

Cold Protoflight CPT

Hot Plateau CPT

Cold Plateau CPT


Limited Performance Test Results

As shown in the flow diagram above, Limited Performance Tests are executed in several phases of the LAT-level test program. Outputs of all tests in the sequence are stored in the E-Log database developed and maintained by the LAT Integration and Test Team.

In this section, the LPTs are itemized and each is linked to a spreadsheet listing the test cases executed as part of that test and the associated E-Log run identifiers (RunIDs). Enter the RunID in the Run Range field of the E-Log query page to retrieve the test logs and raw test data associated with each execution.

Pre-Sine Vibe LPT

Post X-Axis Vibe LPT

Post Y-Axis Vibe LPT

Post Z-Axis Vibe LPT part 1 and Post Z-Axis Vibe LPT part 2

Post-EMI/EMC LPT

Post-Acoustic LPT

Hot Plateau 2 LPT

Cold Plateau 2 LPT

Hot Plateau 3 LPT

Cold Plateau 3 LPT


Sine Vibe Test Results

The following documents describe the sine vibration test sequence.

Controlling Test Plan: LAT-MD-01196: LAT Dynamics Test Plan

Pre-Test Analysis Report: LAT-TD-08115: GLAST LAT Protoflight Sine Vibration Pre-Test Analysis

Test Assembly 1: LAT-DS-06187: LAT Environmental Test Horiz Vibe Config Assy

Test Assembly 2: LAT-DS-06190: LAT Environmental Test Vert Vibe Test Config Assy

Test Procedure: LAT-PS-08112: GLAST LAT Protoflight Sine Vibration Test Procedure

Test Report: LAT-TD-08245: GLAST LAT Protoflight Sine Vibration Test Report



EMI/EMC Emissions/Susceptibility Test Results

Outputs of the EMI/EMC test sequence are stored in the E-Log database developed and maintained by the LAT Integration and Test Team.

The following spreadsheets list the test cases executed as part of EMI/EMC testing and the associated E-Log run identifiers (RunIDs). Enter the RunID in the Run Range field of the E-Log query page to retrieve the test logs and raw test data associated with each execution.

EMI Radiated Emissions/Radiated Susceptibility

EMI Conducted Emissions/Conducted Susceptibility

The following documents describe the EMI/EMC testing process.

Test Assembly: LAT-DS-06189: LAT Environmental Test EMI Test Config Assy

Test Procedure: LAT-MD-02726: LAT EMI/EMC Test Plan

Test Report: LAT-TD-08586: LAT Electromagnetic Interference (EMI) Test Report


Acoustic Test Results

The following documents describe the acoustic test sequence.

Controlling Test Plan: LAT-MD-01196-03: LAT Dynamics Test Plan

Pre-Test Analysis Report: LAT-TD-08116: GLAST LAT Protoflight Acoustic Vibration Pre-Test Analysis

Test Assembly: LAT-DS-06188: LAT Environmental Test Acoustic Test Config Assy

Test Procedure: LAT-PS-08113: GLAST LAT Protoflight Acoustic Vibration Test Procedure

Test Report: LAT-TD-08245 GLAST LAT Protoflight Sine Vibration Test Report



Thermal Vac Test Results

Outputs of the Thermal Vac test sequence are stored in the E-Log database developed and maintained by the LAT Integration and Test Team.

The following spreadsheets list the test cases executed as part of Thermal Vac testing and the associated E-Log run identifiers (RunIDs). Enter the RunID in the Run Range field of the E-Log query page to retrieve the test logs and raw test data associated with each execution. Note that additional CPTs and LPTs are executed while the LAT is in the chamber.

Thermal Vac Bake Out

Hot Thermal Balance

Hot 1 to Cold Survival Transition

Cold Survival

Cold Thermal Balance

Cold 1 to Hot 2 Transition

Hot 2 to Cold 2 Transition

Cold 2 to Hot 3 Transition

Hot 3 to Cold 3 Transition

Cold 3 to Hot 4 Transition

Hot 4 to Cold 4 Transition

Cold 4 to Hot Transition

The following documents describe the Thermal Vac test sequence.

Controlling Test Plan: LAT-MD-01600: LAT Thermal Vacuum Test Plan

Test Assembly: LAT-DS-06185: LAT ENVIRONMENTAL TEST T-VAC TEST CONFIG ASSY

Thermal Vacuum Test Procedure: LAT-TD-06799: LAT Thermal Vacuum Test Procedure


Weight CG Test Results

The mass properties test sequence is described in the following documents.

Controlling Test Plan: LAT-MD-01196-03: LAT Dynamics Test Plan

Test Procedure: LAT-TD-08114 GLAST LAT Mass Properties Test Procedure

Test Report: LAT-TD-08247 GLAST LAT Weight and CG Test Report