#================================================================================# # Mode Management PV # # Macro description: # # - IOC : IOC Prefix, example SIOC:GUNB:BP01 # # - INPV : Input PV to Monitor (Global Mode PV), # # Example "PHYS:UNDH:1:FACMODE CPP MSI" # # Be sure to include CPP specifier # # If mode never changes, set to 0 for NC or 1 for SC. # # Default is 1 # # - FLNK : PV that FACMODE should drive for application-specific settings # # (e.g. change TPR mode) # # Default is empty # # - INPR : Input PV containing FACMODE readback. # # Include MS/MSI/PP specifier(s) if desired # # Default is to use FACMODE setting # # - ASG : Access Security group for overriding mode selection. # # Default is MCC group # #================================================================================# record(mbbo, "$(IOC):FACMODE_INP"){ field(DESC, "Bring in Facility mode to IOC") field(PINI, "YES") field(OMSL, "closed_loop") field(DOL, "$(INPV)") field(ZRST, "NC") field(ZRVL, "0") field(ZRSV, "NO_ALARM") field(ONST, "SC") field(ONVL, "1") field(ONSV, "NO_ALARM") field(FLNK, "$(IOC):FACMODE_CALC") } record(bo, "$(IOC):FACMODE_AUTO") { field(DESC, "IOC Mode will follow FACMODE_INP") field(PINI, "YES") field(ZNAM, "Override") field(ONAM, "Global") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(VAL, "1") field(FLNK, "$(IOC):FACMODE_CALC") info(autosaveFields, "VAL") } record(mbbo, "$(IOC):FACMODE_USER") { field(DESC, "Bring in Facility mode to IOC") field(PINI, "YES") field(VAL, "$(MODE_DEFAULT)") field(SCAN, "Passive") field(ZRST, "NC") field(ZRVL, "0") field(ZRSV, "NO_ALARM") field(ONST, "SC") field(ONVL, "1") field(ONSV, "NO_ALARM") field(FLNK, "$(IOC):FACMODE_CALC") info(autosaveFields, "VAL") } record(calc, "$(IOC):FACMODE_CALC") { field(DESC, "Calc the Facility Mode") field(SCAN, "Passive") field(INPA, "$(IOC):FACMODE_INP MSI") field(INPB, "$(IOC):FACMODE_AUTO MSI") field(INPC, "$(IOC):FACMODE_USER MSI") field(CALC, "B?A:C") field(FLNK, "$(IOC):FACMODE") } record(calc, "$(IOC):FACMODE_STAT_CALC") { field(DESC, "NC/SC Mode Status") field(SCAN, "1 second") field(INPA, "$(IOC):FACMODE_RBV MSI") field(INPB, "$(INPV)") field(INPC, "$(IOC):FACMODE_AUTO MSI") field(CALC, "(A#B)?0:(C=0)?1:2") field(FLNK, "$(IOC):FACMODE_STAT") } record(mbbi, "$(IOC):FACMODE_STAT") { field(DESC, "NC/SC Mode Status") field(INP, "$(IOC):FACMODE_STAT_CALC MSI") field(ZRST, "Mismatch") field(ZRVL, "0") field(ZRSV, "MAJOR") field(ONVL, "1") field(ONST, "Override") field(ONSV, "MINOR") field(TWVL, "2") field(TWST, "OK") field(TWSV, "NO_ALARM") } record(mbbo, "$(IOC):FACMODE"){ field(PINI, "YES") field(DESC, "NC/SC Mode Set") field(ZRST, "NC") field(ONST, "SC") field(OMSL, "closed_loop") field(DOL, "$(IOC):FACMODE_CALC MSI") field(FLNK, "$(IOC):SET_FACMODE") } record(mbbi, "$(IOC):FACMODE_RBV"){ field(DESC, "Node Timing Mode Readback") field(INP, "$(IOC):FACMODE") field(SCAN, "1 second") field(ZRVL, "0") field(ZRST, "NC") field(ONVL, "1") field(ONST, "SC") field(TWST, "Unknown") field(TWVL, "2") field(TWSV, "MAJOR") } record(fanout, "$(IOC):SET_FACMODE"){ field(DESC, "Internal") field(SCAN, "Passive") field(LNK0, "$(IOC):SET_TPRMODE") field(LNK1, "$(IOC):SET_BEAMRATE") field(LNK2, "$(IOC):SET_BEAMCHARGE") } #TPR MODE 0 for NC 1 for SC record(calcout, "$(IOC):SET_TPRMODE"){ field(DESC, "Internal") field(SCAN, "Passive") field(INPA, "$(IOC):FACMODE") field(CALC, "!A ? 0 : 1") field(OUT, "$(TPR):MODE") field(FLNK, "$(TPR):MODE") } #TPR MODE 0 for NC 1 for SC #Crossbar control should be BP record(calc, "$(IOC):FACMODERBV_CALC"){ field(DESC, "Timing Mode Cacluation") field(SCAN, "1 second") field(INPA, "$(TPR):MODE") field(INPB, "$(TPR):TCRB:CONFIG_STS") field(CALC, "B?(A):2") }