#! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(stringin, "$(DEVICE)IDENTITY") { field(DESC, "Identification") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_IDN $(PORT)") } record(bo, "$(DEVICE)RESET") { field(DESC, "Reset command") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto RESET $(PORT)") field(FLNK, "$(DEVICE)UPDATE") } record(fanout, "$(DEVICE)UPDATE") { field(DESC, "Update all settings") field(LNK1, "$(DEVICE)GET_IMPEDANCE") field(LNK2, "$(DEVICE)GET_TRIG_LEVEL") field(LNK3, "$(DEVICE)GET_TRIG_PERCENT") field(LNK4, "$(DEVICE)GET_AUTO_LEVEL") field(LNK5, "$(DEVICE)GET_COUPLING") field(LNK6, "$(DEVICE)GET_NOISE_REJ") } record(ai, "$(DEVICE)FREQ_RBCK_RAW") { field(DESC, "Measured frequency") field(SCAN, "$(SCAN)") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_FREQ $(PORT)") field(EGU, "Hz") field(PREC, "3") info(autosaveFields, "DESC EGU HHSV HIGH HIHI HSV LLSV LOLO LOW LSV PREC") } record(calcout, "$(DEVICE)FREQ_RBCK_PROC_") { field(DESC, "Update only when readback is sensible") field(CALC, "A<1000000000") field(INPA, "$(DEVICE)FREQ_RBCK_RAW CP MS") field(OUT, "$(DEVICE)FREQ_RBCK PP MS") field(OOPT, "When Non-zero") field(DOPT, "Use OCAL") field(OCAL, "A") field(LOW, "0") field(LSV, "INVALID") } record(ai, "$(DEVICE)FREQ_RBCK") { field(DESC, "Measured frequency") field(EGU, "Hz") field(PREC, "3") info(autosaveFields, "DESC EGU HHSV HIGH HIHI HSV LLSV LOLO LOW LSV PREC") } record(bi, "$(DEVICE)GET_IMPEDANCE") { field(DESC, "Input Impedance") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_IMPEDANCE $(PORT)") field(ZNAM, "1M Ohm") field(ONAM, "50 Ohm") info(autosaveFields, "ZSV OSV") } record(bo, "$(DEVICE)SET_IMPEDANCE") { field(DESC, "Input Impedance") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto SET_IMPEDANCE $(PORT)") field(ZNAM, "1M Ohm") field(ONAM, "50 Ohm") field(FLNK, "$(DEVICE)GET_IMPEDANCE") info(autosaveFields, "VAL ZSV OSV") } record(ai, "$(DEVICE)GET_TRIG_LEVEL") { field(DESC, "Trigger level") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_TRIG_LEVEL $(PORT)") field(EGU, "V") field(PREC, "3") info(autosaveFields, "DESC EGU HHSV HIGH HIHI HSV LLSV LOLO LOW LSV PREC") } record(ao, "$(DEVICE)SET_TRIG_LEVEL") { field(DESC, "Trigger level") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto SET_TRIG_LEVEL $(PORT)") field(EGU, "V") field(PREC, "3") field(FLNK, "$(DEVICE)GET_TRIG_LEVEL") info(autosaveFields, "VAL DESC EGU HHSV HIGH HIHI HSV LLSV LOLO LOW LSV PREC") } record(ai, "$(DEVICE)GET_TRIG_PERCENT") { field(DESC, "Trigger percent") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_TRIG_PERCENT $(PORT)") field(EGU, "V") field(PREC, "3") info(autosaveFields, "DESC EGU HHSV HIGH HIHI HSV LLSV LOLO LOW LSV PREC") } record(ao, "$(DEVICE)SET_TRIG_PERCENT") { field(DESC, "Trigger percent") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto SET_TRIG_PERCENT $(PORT)") field(EGU, "V") field(PREC, "3") field(FLNK, "$(DEVICE)GET_TRIG_PERCENT") info(autosaveFields, "VAL DESC EGU HHSV HIGH HIHI HSV LLSV LOLO LOW LSV PREC") } record(mbbi, "$(DEVICE)GET_AUTO_LEVEL") { field(DESC, "Input AUTO_LEVEL") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_AUTO_LEVEL $(PORT)") field(ZRST, "OFF") field(ONST, "ON") field(TWST, "ONCE") info(autosaveFields, "UNSV COSV ZRSV ONSV TWSV") } record(mbbo, "$(DEVICE)SET_AUTO_LEVEL") { field(DESC, "Input AUTO_LEVEL") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto SET_AUTO_LEVEL $(PORT)") field(ZRST, "OFF") field(ONST, "ON") field(TWST, "ONCE") field(FLNK, "$(DEVICE)GET_AUTO_LEVEL") info(autosaveFields, "VAL UNSV COSV ZRSV ONSV TWSV") } record(bi, "$(DEVICE)GET_COUPLING") { field(DESC, "Input Coupling") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_COUPLING $(PORT)") field(ZNAM, "AC") field(ONAM, "DC") info(autosaveFields, "ZSV OSV") } record(bo, "$(DEVICE)SET_COUPLING") { field(DESC, "Input Coupling") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto SET_COUPLING $(PORT)") field(ZNAM, "AC") field(ONAM, "DC") field(FLNK, "$(DEVICE)GET_COUPLING") info(autosaveFields, "VAL ZSV OSV") } record(bi, "$(DEVICE)GET_NOISE_REJ") { field(DESC, "Noise rejection") field(DTYP, "stream") field(INP, "@Agilent53220A.proto GET_NOISE_REJ $(PORT)") field(ZNAM, "OFF") field(ONAM, "ON") info(autosaveFields, "ZSV OSV") } record(bo, "$(DEVICE)SET_NOISE_REJ") { field(DESC, "Noise rejection") field(DTYP, "stream") field(OUT, "@Agilent53220A.proto SET_NOISE_REJ $(PORT)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "$(DEVICE)GET_NOISE_REJ") info(autosaveFields, "VAL ZSV OSV") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("$(DEVICE)IDENTITY",20,22,0,0,"$(DEVICE)IDENTITY") #! Record("$(DEVICE)RESET",500,22,0,0,"$(DEVICE)RESET") #! Record("$(DEVICE)FREQ_RBCK_RAW",80,200,0,0,"$(DEVICE)FREQ_RBCK_RAW") #! Field("$(DEVICE)FREQ_RBCK_RAW.VAL",16777215,1,"$(DEVICE)FREQ_RBCK_RAW.VAL") #! Record("$(DEVICE)FREQ_RBCK_PROC_",340,159,0,1,"$(DEVICE)FREQ_RBCK_PROC_") #! Field("$(DEVICE)FREQ_RBCK_PROC_.INPA",16777215,0,"$(DEVICE)FREQ_RBCK_PROC_.INPA") #! Link("$(DEVICE)FREQ_RBCK_PROC_.INPA","$(DEVICE)FREQ_RBCK_RAW.VAL") #! Field("$(DEVICE)FREQ_RBCK_PROC_.OUT",16777215,1,"$(DEVICE)FREQ_RBCK_PROC_.OUT") #! Link("$(DEVICE)FREQ_RBCK_PROC_.OUT","$(DEVICE)FREQ_RBCK.VAL") #! Record("$(DEVICE)FREQ_RBCK",680,262,0,1,"$(DEVICE)FREQ_RBCK") #! Field("$(DEVICE)FREQ_RBCK.VAL",16777215,0,"$(DEVICE)FREQ_RBCK.VAL")