 *    Trigger Control
 *    Auth: KHKIM
 *
*/

program pacTrgControl

option +r;    /* enable the re-entrant */

%{
#define ENABLE        1
#define DISABLE       0
#define NO_ACCEL_BIT  (0x8000)
}%

long     klyMode;
assign   klyMode to "{KLY_MODE}";
monitor  klyMode;

long      pacTrig;
assign   pacTrig to "{PAC_TRIG}";

ss trigControl
{
    state init
    {
        when(klyMode & NO_ACCEL_BIT)    {} state disable
        when(!(klyMode & NO_ACCEL_BIT)) {} state enable
    }

    state enable
    {
        entry { 
            pacTrig = ENABLE; pvPut(pacTrig);
        }
        when(klyMode & NO_ACCEL_BIT) {} state disable
    }

    state disable
    {
        entry { 
            pacTrig = DISABLE; pvPut(pacTrig);
        }
        when(!(klyMode & NO_ACCEL_BIT)) {} state enable
    }
}