# Two simulated BSA PV Data Sources
# (1) A simple counter
# (2) A sine wave
# The above data source wakes up and becomes active whenever event 40 is seen
# from the EVG
# ===============================================================================
# ===============================================================================
# Macros:
#       DEVICE  Name of the beam synchronous triggered device.
# ===============================================================================
record(ai, $(DEVICE):$(ID):COUNTER) {
  field(DESC, "pulse id")
  field(INPA, "IOC:B34:EV02:PATTERN360HZ.L")
  field(EVNT, "$(EVNT)")
  field(TSE,  "-1")
}



record(seq, $(DEVICE):$(ID):COUNTDUP) {
}