#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND


record(motor, "PHAS:UND1:3340:MOTR") {
  field(DESC, "Phase Shifter")
  field(DTYP, "asynMotor")
  field(DIR, "Pos")
  field(VELO, "0.2")
  field(VBAS, "0.1")
  field(ACCL, "1")
  field(OUT, "@asyn(S5,0)")
  field(MRES, "0.00003175")
  field(RRES, "0.001")
  field(PREC, "4")
  field(EGU, "mm")
  field(DHLM, "100")
  field(DLLM, "11")
  field(URIP, "Yes")
  field(URIP, "1")
  field(TWV, "0.1")
  field(ASG, "")
  field(OFF, "0")
  field(OMSL, "supervisory")
  field(DOL, "")
  info(autosaveFields_pass0, "VAL DVAL")
  info(autosaveFields, "DIR DESC VELO VBAS VMAX ACCL MRES ERES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP UEIP PREC FOFF OFF FRAC OMSL JVEL JAR PCOF ICOF DCOF HVEL NTM NTMF INIT PREM POST FLNK")
}

# Database for Animatics SmartMotor

record(ai,"PHAS:UND1:3340:TEMP") {
    field(DESC,"Smart Motor Temp")
    field(EGU,"C")
    field(PREC,"3")
    field(HIGH, "50")
    field(HSV, "MINOR")
    field(HIHI, "55")
    field(HSV, "MAJOR")
    field(DTYP, "asynFloat64")
    field(SCAN, "I/O Intr")
    field(INP,"@asyn(S5,0)SMART_TEMP")
}
record(ai,"PHAS:UND1:3340:TORQUE") {
    field(DESC,"Smart Motor Torque")
    field(EGU,"mA")
    field(PREC,"3")
    field(HIGH, "2100")
    field(HSV, "MINOR")
    field(HIHI, "2700")
    field(HSV, "MAJOR")
    field(DTYP, "asynFloat64")
    field(SCAN, "I/O Intr")
    field(INP,"@asyn(S5,0)SMART_TORQUE")
}
record(stringin,"PHAS:UND1:3340:FW") {
    field(DESC,"Smart Motor FW")
    field(DTYP, "asynOctetRead")
    field(SCAN, "I/O Intr")
    field(INP,  "@asyn(S5,0)SMART_FW")
}

record(stringin,"PHAS:UND1:3340:ERROR") {
    field(DESC,"Smart Motor Error String")
    field(DTYP, "asynOctetRead")
    field(SCAN, "I/O Intr")
    field(INP,  "@asyn(S5,0)SMART_ERROR")
}

record(ai,"PHAS:UND1:3340:MCTR0") {
    field(DESC,"Motor Torque")
    field(PREC,"3")
    field(DTYP, "asynFloat64")
    field(SCAN, "I/O Intr")
    field(INP,"@asyn(S5,0)SMART_CTR0")
}
record(ai,"PHAS:UND1:3340:MCTR1") {
    field(DESC,"Motor Torque")
    field(PREC,"3")
    field(DTYP, "asynFloat64")
    field(SCAN, "I/O Intr")
    field(INP,"@asyn(S5,0)SMART_CTR1")
}


record(calcout, "PHAS:UND1:3340:BRKCNTCLC") {
    field(DESC,"Number of brake cycles")
    field(CALC,"A+B")
    field(OUT,"PHAS:UND1:3340:BRKCNT")
    field(INPA,"PHAS:UND1:3340:BRKCNT PP")
    field(INPB,"PHAS:UND1:3340:MOTR.CNEN CP")
    field(SCAN,"Passive")
}

record(ao, "PHAS:UND1:3340:BRKCNT") {
    field(DESC,"Number of brake cycles")
    field(VAL, "0")
    field(PINI, "YES")
    info(autosaveFields, "VAL")
}

record(ai,"PHAS:UND1:3340:STATUS") {
    field(DESC,"Smart motor status")
    field(PREC,"3")
    field(DTYP, "asynInt32")
    field(SCAN, "I/O Intr")
    field(INP,"@asyn(S5,0)SMART_STATUS")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND


# 2000 steps/rev
record(motor, "USEG:UND1:$(seg,undefined)50:TM1MOTOR") {
  field(DESC, "Translation Motor")
  field(SCAN, "Passive")
  field(DTYP, "asynMotor")
  field(DISS, "NO_ALARM")
  field(DIR, "Neg")
  field(VELO, "0.5")
  field(VBAS, "0.1")
  field(VMAX, "3.67")
  field(URIP, "No")
  field(PREC, "4")
  field(EGU, "mm")
  field(DHLM, "5.51")
  field(DLLM, "-84.5")
  field(RRES, "1")
  field(OUT, "@asyn(motorSim1,0)")
  field(RDBD, "0.001")
  field(TWV, "0.1")
  field(ASG, "")
  field(SREV, "2000")
  field(UREV, "0.1016")
  field(FOFF, "Frozen")
  field(PRIO, "HIGH")
  field(OMSL, "supervisory")
  field(DOL, "USEG:UND1:$(seg,undefined)50:TMXPOSC")
  field(OFF, "0")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("USEG:UND1:$(seg,undefined)50:TM1MOTOR",20,17,0,0,"USEG:UND1:$(seg,undefined)50:TM1MOTOR")
#! Field("USEG:UND1:$(seg,undefined)50:TM1MOTOR.DOL",16777215,1,"USEG:UND1:$(seg,undefined)50:TM1MOTOR.DOL")
#! Field("USEG:UND1:$(seg,undefined)50:TM1MOTOR.OUT",16777215,1,"USEG:UND1:$(seg,undefined)50:TM1MOTOR.OUT")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBDEND


# 2000 steps/rev
record(motor, "USEG:UND1:$(seg,undefined)50:TM2MOTOR") {
  field(DESC, "Translation Motor")
  field(SCAN, "Passive")
  field(DTYP, "asynMotor")
  field(DISS, "NO_ALARM")
  field(DIR, "Neg")
  field(VELO, "0.5")
  field(VBAS, "0.1")
  field(VMAX, "3.67")
  field(URIP, "No")
  field(PREC, "4")
  field(EGU, "mm")
  field(DHLM, "5.51")
  field(DLLM, "-84.5")
  field(RRES, "1")
  field(OUT, "@asyn(motorSim1,1)")
  field(RDBD, "0.001")
  field(TWV, "0.1")
  field(ASG, "")
  field(SREV, "2000")
  field(UREV, "0.1016")
  field(FOFF, "Frozen")
  field(PRIO, "HIGH")
  field(OMSL, "supervisory")
  field(DOL, "USEG:UND1:$(seg,undefined)50:TMXPOSC")
  field(OFF, "0")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("USEG:UND1:$(seg,undefined)50:TM2MOTOR",20,17,0,0,"USEG:UND1:$(seg,undefined)50:TM2MOTOR")
#! Field("USEG:UND1:$(seg,undefined)50:TM2MOTOR.DOL",16777215,1,"USEG:UND1:$(seg,undefined)50:TM2MOTOR.DOL")
#! Field("USEG:UND1:$(seg,undefined)50:TM2MOTOR.OUT",16777215,1,"USEG:UND1:$(seg,undefined)50:TM2MOTOR.OUT")