#--- Device info ------------------------ record(stringout, "$(P):LOCATION") { field(DESC, "Device location") field(VAL, "$(LOC)") field(PINI, "1") info(autosaveFields, "VAL") } record(mbbo, "$(P):TYPE") { field(DESC, "Device type") field(ZRVL, "0") field(ZRST, "Thermo FHT") field(ONVL, "1") field(ONST, "RadFET") field(TWVL, "2") field(TWST, "Air Mon Sys") field(THVL, "3") field(THST, "Periphal Mon Sys") field(VAL, "0") field(PINI, "1") info(autosaveFields, "VAL") } #--- Device parameters ----------------------------------- record(stringin, "$(P):DEV_SN") { field(DESC, "Serial number") field(DTYP, "asynOctetRead") field(INP, "@asyn($(PORT) 0) SN") field(SCAN, "I/O Intr") } record(stringin, "$(P):DEV_FW") { field(DESC, "Firmware") field(DTYP, "asynOctetRead") field(INP, "@asyn($(PORT) 0) FW") field(SCAN, "I/O Intr") } record(stringin, "$(P):DEV_TYPE") { field(DESC, "Device type") field(DTYP, "asynOctetRead") field(INP, "@asyn($(PORT) 0) DEV_TYPE") field(SCAN, "I/O Intr") } record(stringin, "$(P):DEV_TIME") { field(DESC, "Date and time from device") field(DTYP, "asynOctetRead") field(INP, "@asyn($(PORT) 0) DEV_TIME") field(SCAN, "I/O Intr") field(FLNK, "$(P):Heartbeat") } record(longin, "$(P):DEV_ADDR") { field(DESC, "Device address") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT) 0) DEV_ADDR") field(SCAN, "I/O Intr") } record(longin, "$(P):DEV_POLL_INT") { field(DESC, "Data polling interval") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT) 0) POLL_INT") field(EGU, "s") field(SCAN, "I/O Intr") } record(longout, "$(P):DEV_POLL_I_S") { field(DESC, "Set data polling int.") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT) 0) POLL_INT") field(EGU, "s") info(asyn:READBACK, "1") } #--- Status ----------------------------------- record(longin, "$(P):STATUS_SYS") { field(DESC, "System status") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT) 0) STATUS_SYS") field(SCAN, "I/O Intr") } #--- Channel ----------------------------------- record(bi, "$(P):CH_MODE") { field(DESC, "Channel mode") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT) 0) CHAN_MODE") field(ZNAM, "Multi-channel") field(ONAM, "Single channel") field(SCAN, "I/O Intr") } record(bo, "$(P):CH_READ_ALL") { field(DESC, "Read all channels") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT) 0) CHAN_READALL") field(ZNAM, "No") field(ONAM, "Yes") field(ZSV, "MINOR") field(PINI, "1") field(VAL, "0") info(autosaveFields, "VAL") } record(longin, "$(P):CH_CHAN") { field(DESC, "Single channel mode: channel") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT) 0) CHAN_CHAN") field(SCAN, "I/O Intr") } #--- Misc. ----------------------------------- record(bo, "$(P):HW_RESET") { field(DESC, "Hardware reset") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT) 0) HW_RESET") } #--- Heartbeat, ... ------------------------------- record(calcout, "$(P):Heartbeat"){ field(DESC, "Heartbeat") field(CALC, "VAL>=100?0:(VAL+1)") field(DOPT, "Use OCAL") field(OCAL, "0") field(OVAL, "0") field(OUT, "$(P):ErrorCount PP") } record(calcout, "$(P):ErrorCount"){ field(DESC, "Errors since last read") field(INPA, "$(P):ErrorCount") field(CALC, "(VAL+5)") field(SCAN, "5 second") field(HIHI, "7") field(HHSV, "MAJOR") field(DOPT, "Use OCAL") field(OCAL, "(A>10)?1:0") field(OUT, "$(P):ReadStatus PP") } record(bi, "$(P):ReadStatus"){ field(DESC, "Read status") field(ZNAM, "OK") field(ONAM, "ERROR") field(OSV, "MAJOR") } #--- Chan. 01 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH01:MEAS") { field(DESC, "Meas. value, ch. 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH01:STATUS") { field(DESC, "Meas. val. status, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH01:STATE") { field(DESC, "Channel state, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH01:STATE_SET") { field(DESC, "Set channel state, ch. 01") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 1, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH01:DISPUNITS") { field(DESC, "Display units, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH01:USERUNITS") { field(DESC, "User units, ch. 01") field(OUT, "$(P):CH01:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH01:DISPFACTOR") { field(DESC, "Display factor, ch. 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH01:PREUNIT") { field(DESC, "Pre-unit, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH01:PROBETYPE") { field(DESC, "Channel type, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH01:PORT") { field(DESC, "Port, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH01:DECODE") { field(DESC, "Decode, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH01:ADDR") { field(DESC, "Address, ch. 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 02 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH02:MEAS") { field(DESC, "Meas. value, ch. 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH02:STATUS") { field(DESC, "Meas. val. status, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH02:STATE") { field(DESC, "Channel state, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH02:STATE_SET") { field(DESC, "Set channel state, ch. 02") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 2, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH02:DISPUNITS") { field(DESC, "Display units, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH02:USERUNITS") { field(DESC, "User units, ch. 02") field(OUT, "$(P):CH02:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH02:DISPFACTOR") { field(DESC, "Display factor, ch. 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH02:PREUNIT") { field(DESC, "Pre-unit, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH02:PROBETYPE") { field(DESC, "Channel type, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH02:PORT") { field(DESC, "Port, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH02:DECODE") { field(DESC, "Decode, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH02:ADDR") { field(DESC, "Address, ch. 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 03 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH03:MEAS") { field(DESC, "Meas. value, ch. 03") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 3, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH03:STATUS") { field(DESC, "Meas. val. status, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH03:STATE") { field(DESC, "Channel state, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH03:STATE_SET") { field(DESC, "Set channel state, ch. 03") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 3, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH03:DISPUNITS") { field(DESC, "Display units, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH03:USERUNITS") { field(DESC, "User units, ch. 03") field(OUT, "$(P):CH03:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH03:DISPFACTOR") { field(DESC, "Display factor, ch. 03") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 3, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH03:PREUNIT") { field(DESC, "Pre-unit, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH03:PROBETYPE") { field(DESC, "Channel type, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH03:PORT") { field(DESC, "Port, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH03:DECODE") { field(DESC, "Decode, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH03:ADDR") { field(DESC, "Address, ch. 03") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 3, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 04 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH04:MEAS") { field(DESC, "Meas. value, ch. 04") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 4, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH04:STATUS") { field(DESC, "Meas. val. status, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH04:STATE") { field(DESC, "Channel state, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH04:STATE_SET") { field(DESC, "Set channel state, ch. 04") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 4, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH04:DISPUNITS") { field(DESC, "Display units, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH04:USERUNITS") { field(DESC, "User units, ch. 04") field(OUT, "$(P):CH04:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH04:DISPFACTOR") { field(DESC, "Display factor, ch. 04") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 4, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH04:PREUNIT") { field(DESC, "Pre-unit, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH04:PROBETYPE") { field(DESC, "Channel type, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH04:PORT") { field(DESC, "Port, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH04:DECODE") { field(DESC, "Decode, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH04:ADDR") { field(DESC, "Address, ch. 04") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 4, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 05 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH05:MEAS") { field(DESC, "Meas. value, ch. 05") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 5, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH05:STATUS") { field(DESC, "Meas. val. status, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH05:STATE") { field(DESC, "Channel state, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH05:STATE_SET") { field(DESC, "Set channel state, ch. 05") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 5, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH05:DISPUNITS") { field(DESC, "Display units, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH05:USERUNITS") { field(DESC, "User units, ch. 05") field(OUT, "$(P):CH05:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH05:DISPFACTOR") { field(DESC, "Display factor, ch. 05") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 5, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH05:PREUNIT") { field(DESC, "Pre-unit, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH05:PROBETYPE") { field(DESC, "Channel type, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH05:PORT") { field(DESC, "Port, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH05:DECODE") { field(DESC, "Decode, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH05:ADDR") { field(DESC, "Address, ch. 05") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 5, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 06 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH06:MEAS") { field(DESC, "Meas. value, ch. 06") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 6, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH06:STATUS") { field(DESC, "Meas. val. status, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH06:STATE") { field(DESC, "Channel state, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH06:STATE_SET") { field(DESC, "Set channel state, ch. 06") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 6, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH06:DISPUNITS") { field(DESC, "Display units, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH06:USERUNITS") { field(DESC, "User units, ch. 06") field(OUT, "$(P):CH06:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH06:DISPFACTOR") { field(DESC, "Display factor, ch. 06") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 6, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH06:PREUNIT") { field(DESC, "Pre-unit, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH06:PROBETYPE") { field(DESC, "Channel type, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH06:PORT") { field(DESC, "Port, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH06:DECODE") { field(DESC, "Decode, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH06:ADDR") { field(DESC, "Address, ch. 06") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 6, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 07 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH07:MEAS") { field(DESC, "Meas. value, ch. 07") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 7, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH07:STATUS") { field(DESC, "Meas. val. status, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH07:STATE") { field(DESC, "Channel state, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH07:STATE_SET") { field(DESC, "Set channel state, ch. 07") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 7, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH07:DISPUNITS") { field(DESC, "Display units, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH07:USERUNITS") { field(DESC, "User units, ch. 07") field(OUT, "$(P):CH07:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH07:DISPFACTOR") { field(DESC, "Display factor, ch. 07") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 7, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH07:PREUNIT") { field(DESC, "Pre-unit, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH07:PROBETYPE") { field(DESC, "Channel type, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH07:PORT") { field(DESC, "Port, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH07:DECODE") { field(DESC, "Decode, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH07:ADDR") { field(DESC, "Address, ch. 07") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 7, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 08 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH08:MEAS") { field(DESC, "Meas. value, ch. 08") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 8, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH08:STATUS") { field(DESC, "Meas. val. status, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH08:STATE") { field(DESC, "Channel state, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH08:STATE_SET") { field(DESC, "Set channel state, ch. 08") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 8, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH08:DISPUNITS") { field(DESC, "Display units, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH08:USERUNITS") { field(DESC, "User units, ch. 08") field(OUT, "$(P):CH08:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH08:DISPFACTOR") { field(DESC, "Display factor, ch. 08") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 8, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH08:PREUNIT") { field(DESC, "Pre-unit, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH08:PROBETYPE") { field(DESC, "Channel type, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH08:PORT") { field(DESC, "Port, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH08:DECODE") { field(DESC, "Decode, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH08:ADDR") { field(DESC, "Address, ch. 08") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 8, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 09 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH09:MEAS") { field(DESC, "Meas. value, ch. 09") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 9, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH09:STATUS") { field(DESC, "Meas. val. status, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH09:STATE") { field(DESC, "Channel state, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH09:STATE_SET") { field(DESC, "Set channel state, ch. 09") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 9, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH09:DISPUNITS") { field(DESC, "Display units, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH09:USERUNITS") { field(DESC, "User units, ch. 09") field(OUT, "$(P):CH09:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH09:DISPFACTOR") { field(DESC, "Display factor, ch. 09") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 9, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH09:PREUNIT") { field(DESC, "Pre-unit, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH09:PROBETYPE") { field(DESC, "Channel type, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH09:PORT") { field(DESC, "Port, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH09:DECODE") { field(DESC, "Decode, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH09:ADDR") { field(DESC, "Address, ch. 09") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 9, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 10 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH10:MEAS") { field(DESC, "Meas. value, ch. 10") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 10, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH10:STATUS") { field(DESC, "Meas. val. status, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH10:STATE") { field(DESC, "Channel state, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH10:STATE_SET") { field(DESC, "Set channel state, ch. 10") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 10, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH10:DISPUNITS") { field(DESC, "Display units, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH10:USERUNITS") { field(DESC, "User units, ch. 10") field(OUT, "$(P):CH10:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH10:DISPFACTOR") { field(DESC, "Display factor, ch. 10") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 10, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH10:PREUNIT") { field(DESC, "Pre-unit, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH10:PROBETYPE") { field(DESC, "Channel type, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH10:PORT") { field(DESC, "Port, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH10:DECODE") { field(DESC, "Decode, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH10:ADDR") { field(DESC, "Address, ch. 10") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 10, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 11 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH11:MEAS") { field(DESC, "Meas. value, ch. 11") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 11, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH11:STATUS") { field(DESC, "Meas. val. status, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH11:STATE") { field(DESC, "Channel state, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH11:STATE_SET") { field(DESC, "Set channel state, ch. 11") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 11, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH11:DISPUNITS") { field(DESC, "Display units, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH11:USERUNITS") { field(DESC, "User units, ch. 11") field(OUT, "$(P):CH11:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH11:DISPFACTOR") { field(DESC, "Display factor, ch. 11") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 11, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH11:PREUNIT") { field(DESC, "Pre-unit, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH11:PROBETYPE") { field(DESC, "Channel type, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH11:PORT") { field(DESC, "Port, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH11:DECODE") { field(DESC, "Decode, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH11:ADDR") { field(DESC, "Address, ch. 11") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 11, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 12 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH12:MEAS") { field(DESC, "Meas. value, ch. 12") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 12, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH12:STATUS") { field(DESC, "Meas. val. status, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH12:STATE") { field(DESC, "Channel state, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH12:STATE_SET") { field(DESC, "Set channel state, ch. 12") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 12, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH12:DISPUNITS") { field(DESC, "Display units, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH12:USERUNITS") { field(DESC, "User units, ch. 12") field(OUT, "$(P):CH12:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH12:DISPFACTOR") { field(DESC, "Display factor, ch. 12") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 12, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH12:PREUNIT") { field(DESC, "Pre-unit, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH12:PROBETYPE") { field(DESC, "Channel type, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH12:PORT") { field(DESC, "Port, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH12:DECODE") { field(DESC, "Decode, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH12:ADDR") { field(DESC, "Address, ch. 12") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 12, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 13 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH13:MEAS") { field(DESC, "Meas. value, ch. 13") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 13, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH13:STATUS") { field(DESC, "Meas. val. status, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH13:STATE") { field(DESC, "Channel state, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH13:STATE_SET") { field(DESC, "Set channel state, ch. 13") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 13, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH13:DISPUNITS") { field(DESC, "Display units, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH13:USERUNITS") { field(DESC, "User units, ch. 13") field(OUT, "$(P):CH13:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH13:DISPFACTOR") { field(DESC, "Display factor, ch. 13") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 13, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH13:PREUNIT") { field(DESC, "Pre-unit, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH13:PROBETYPE") { field(DESC, "Channel type, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH13:PORT") { field(DESC, "Port, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH13:DECODE") { field(DESC, "Decode, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH13:ADDR") { field(DESC, "Address, ch. 13") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 13, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 14 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH14:MEAS") { field(DESC, "Meas. value, ch. 14") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 14, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH14:STATUS") { field(DESC, "Meas. val. status, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH14:STATE") { field(DESC, "Channel state, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH14:STATE_SET") { field(DESC, "Set channel state, ch. 14") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 14, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH14:DISPUNITS") { field(DESC, "Display units, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH14:USERUNITS") { field(DESC, "User units, ch. 14") field(OUT, "$(P):CH14:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH14:DISPFACTOR") { field(DESC, "Display factor, ch. 14") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 14, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH14:PREUNIT") { field(DESC, "Pre-unit, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH14:PROBETYPE") { field(DESC, "Channel type, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH14:PORT") { field(DESC, "Port, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH14:DECODE") { field(DESC, "Decode, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH14:ADDR") { field(DESC, "Address, ch. 14") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 14, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 15 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH15:MEAS") { field(DESC, "Meas. value, ch. 15") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 15, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH15:STATUS") { field(DESC, "Meas. val. status, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH15:STATE") { field(DESC, "Channel state, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH15:STATE_SET") { field(DESC, "Set channel state, ch. 15") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 15, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH15:DISPUNITS") { field(DESC, "Display units, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH15:USERUNITS") { field(DESC, "User units, ch. 15") field(OUT, "$(P):CH15:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH15:DISPFACTOR") { field(DESC, "Display factor, ch. 15") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 15, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH15:PREUNIT") { field(DESC, "Pre-unit, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH15:PROBETYPE") { field(DESC, "Channel type, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH15:PORT") { field(DESC, "Port, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH15:DECODE") { field(DESC, "Decode, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH15:ADDR") { field(DESC, "Address, ch. 15") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 15, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- Chan. 16 -------------------------------- # This record is the Nth channel's measured value. Units depend on the particular # probe and are set in the USERUNITS record below record(ai, "$(P):CH16:MEAS") { field(DESC, "Meas. value, ch. 16") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 16, 0) MEAS") # Units are set in the USERUNITS record below field(EGU, "") field(PREC, "3") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(HYST, "0.5") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") info(autosaveFields, "LOLO LOW HIGH HIHI HYST LLSV LSV HSV HHSV") } record(longin, "$(P):CH16:STATUS") { field(DESC, "Meas. val. status, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) MEAS_STATUS") field(SCAN, "I/O Intr") } record(bi, "$(P):CH16:STATE") { field(DESC, "Channel state, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") field(SCAN, "I/O Intr") } record(bo, "$(P):CH16:STATE_SET") { field(DESC, "Set channel state, ch. 16") field(DTYP, "asynInt32") field(OUT, "@asyn($(PORT), 16, 0) CHAN_STATE") field(ZNAM, "Not Active") field(ONAM, "Active") field(ZSV, "MINOR") info(asyn:READBACK, "1") } record(mbbi, "$(P):CH16:DISPUNITS") { field(DESC, "Display units, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_UNITS") field(ZRVL, "0") field(ZRST, "Invalid") field(ONVL, "1") field(ONST, "Gy") field(TWVL, "2") field(TWST, "Gy/h") field(THVL, "3") field(THST, "Sv") field(FRVL, "4") field(FRST, "Sv/h") field(FVVL, "5") field(FVST, "IPS") field(SXVL, "6") field(SXST, "Bq") field(SVVL, "7") field(SVST, "Bq/cm2") field(EIVL, "8") field(EIST, "Bq/l") field(NIVL, "9") field(NIST, "R") field(TEVL, "10") field(TEST, "R/h") field(ELVL, "11") field(ELST, "User 1") field(TVVL, "12") field(TVST, "User 2") field(TTVL, "13") field(TTST, "User 3") field(FTVL, "14") field(FTST, "User 4") field(FFVL, "15") field(FFST, "User 5") field(SCAN, "I/O Intr") } # This record sets the display units record(stringout, "$(P):CH16:USERUNITS") { field(DESC, "User units, ch. 16") field(OUT, "$(P):CH16:MEAS.EGU PP") field(VAL, "") field(PINI, "1") info(autosaveFields, "VAL") } record(ai, "$(P):CH16:DISPFACTOR") { field(DESC, "Display factor, ch. 16") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 16, 0) CHAN_DISP_FACT") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(bi, "$(P):CH16:PREUNIT") { field(DESC, "Pre-unit, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_PREUNIT") field(ZNAM, "None") field(ONAM, "Auto") field(SCAN, "I/O Intr") } record(mbbi, "$(P):CH16:PROBETYPE") { field(DESC, "Channel type, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_TYPE") field(ZRVL, "0") field(ZRST, "Unknown") field(ONVL, "1") field(ONST, "FHT 191N") field(TWVL, "2") field(TWST, "FHT 191T") field(THVL, "3") field(THST, "FHT 641D") field(FRVL, "4") field(FRST, "FHT 641P") field(FVVL, "5") field(FVST, "FHT 671 Y") field(SXVL, "6") field(SXST, "FHT 751") field(SVVL, "7") field(SVST, "FHZ 621 G-L") field(EIVL, "8") field(EIST, "FHZ 691") field(NIVL, "9") field(NIST, "SRD 2000") field(TEVL, "10") field(TEST, "FH 40G 1") field(ELVL, "11") field(ELST, "FH 40G 2") field(TVVL, "12") field(TVST, "Analog 1") field(TTVL, "13") field(TTST, "Analog 1") field(FTVL, "14") field(FTST, "Digital 1") field(FFVL, "15") field(FFST, "Digital 2") field(SCAN, "I/O Intr") } record(longin, "$(P):CH16:PORT") { field(DESC, "Port, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_PORT") field(SCAN, "I/O Intr") } record(longin, "$(P):CH16:DECODE") { field(DESC, "Decode, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_DECODE") field(SCAN, "I/O Intr") } record(longin, "$(P):CH16:ADDR") { field(DESC, "Address, ch. 16") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 16, 0) CHAN_ADDR") field(SCAN, "I/O Intr") } #--- 40G port 01 -------------------------------------- record(ai, "$(P):40G01:MEAS") { field(DESC, "Meas. value, 40G port 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) MEAS_40G") # field(EGU, "uSv/h") field(PREC, "3") field(SCAN, "I/O Intr") } record(longin, "$(P):40G01:STATUS") { field(DESC, "Meas. val. status, 40G port 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) MEAS_STATUS_40G") field(SCAN, "I/O Intr") } record(ai, "$(P):40G01:SAMPLETIME") { field(DESC, "Meas. time, 40G port 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) MEAS_TIME_40G") field(EGU, "s") field(PREC, "0") field(SCAN, "I/O Intr") } record(longin, "$(P):40G01:PROBETYPE") { field(DESC, "Probe type, 40G port 01") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 1, 0) TYPE_40G") field(SCAN, "I/O Intr") } record(ai, "$(P):40G01:CALFACT") { field(DESC, "Probe cal. factor, 40G port 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) CAL_FACT_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(ai, "$(P):40G01:DEADTIME") { field(DESC, "Probe dead time, 40G port 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) DEAD_TIME_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(ai, "$(P):40G01:DYNRNG") { field(DESC, "Probe dyn. range, 40G port 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) DYN_RNG_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(ai, "$(P):40G01:THRESH") { field(DESC, "Probe sw. thresh., 40G port 01") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 1, 0) SW_THR_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(stringin, "$(P):40G01:CALDATE") { field(DESC, "Probe cal. date, 40G port 01") field(DTYP, "asynOctetRead") field(INP, "@asyn($(PORT), 1, 0) CAL_DATE_40G") field(SCAN, "I/O Intr") } #--- 40G port 02 -------------------------------------- record(ai, "$(P):40G02:MEAS") { field(DESC, "Meas. value, 40G port 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) MEAS_40G") # field(EGU, "uSv/h") field(PREC, "3") field(SCAN, "I/O Intr") } record(longin, "$(P):40G02:STATUS") { field(DESC, "Meas. val. status, 40G port 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) MEAS_STATUS_40G") field(SCAN, "I/O Intr") } record(ai, "$(P):40G02:SAMPLETIME") { field(DESC, "Meas. time, 40G port 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) MEAS_TIME_40G") field(EGU, "s") field(PREC, "0") field(SCAN, "I/O Intr") } record(longin, "$(P):40G02:PROBETYPE") { field(DESC, "Probe type, 40G port 02") field(DTYP, "asynInt32") field(INP, "@asyn($(PORT), 2, 0) TYPE_40G") field(SCAN, "I/O Intr") } record(ai, "$(P):40G02:CALFACT") { field(DESC, "Probe cal. factor, 40G port 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) CAL_FACT_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(ai, "$(P):40G02:DEADTIME") { field(DESC, "Probe dead time, 40G port 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) DEAD_TIME_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(ai, "$(P):40G02:DYNRNG") { field(DESC, "Probe dyn. range, 40G port 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) DYN_RNG_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(ai, "$(P):40G02:THRESH") { field(DESC, "Probe sw. thresh., 40G port 02") field(DTYP, "asynFloat64") field(INP, "@asyn($(PORT), 2, 0) SW_THR_40G") field(EGU, "") field(PREC, "2") field(SCAN, "I/O Intr") } record(stringin, "$(P):40G02:CALDATE") { field(DESC, "Probe cal. date, 40G port 02") field(DTYP, "asynOctetRead") field(INP, "@asyn($(PORT), 2, 0) CAL_DATE_40G") field(SCAN, "I/O Intr") } record(mbbo, "$(P):CH_DISP01") { field(DESC, "Select Channel to display") field(ZRVL, "0") field(ZRST, "1") field(ONVL, "1") field(ONST, "2") field(TWVL, "2") field(TWST, "3") field(THVL, "3") field(THST, "4") field(FRVL, "4") field(FRST, "5") field(FVVL, "5") field(FVST, "6") field(SXVL, "6") field(SXST, "7") field(SVVL, "7") field(SVST, "8") field(EIVL, "8") field(EIST, "9") field(NIVL, "9") field(NIST, "10") field(TEVL, "10") field(TEST, "11") field(ELVL, "11") field(ELST, "12") field(TVVL, "12") field(TVST, "13") field(TTVL, "13") field(TTST, "14") field(FTVL, "14") field(FTST, "15") field(FTVL, "15") field(FTST, "16") field(VAL, "0") field(PINI, "1") info(autosaveFields, "VAL") } record(mbbo, "$(P):CH_DISP02") { field(DESC, "Select Channel to display") field(ZRVL, "0") field(ZRST, "1") field(ONVL, "1") field(ONST, "2") field(TWVL, "2") field(TWST, "3") field(THVL, "3") field(THST, "4") field(FRVL, "4") field(FRST, "5") field(FVVL, "5") field(FVST, "6") field(SXVL, "6") field(SXST, "7") field(SVVL, "7") field(SVST, "8") field(EIVL, "8") field(EIST, "9") field(NIVL, "9") field(NIST, "10") field(TEVL, "10") field(TEST, "11") field(ELVL, "11") field(ELST, "12") field(TVVL, "12") field(TVST, "13") field(TTVL, "13") field(TTST, "14") field(FTVL, "14") field(FTST, "15") field(FTVL, "15") field(FTST, "16") field(VAL, "0") field(PINI, "1") info(autosaveFields, "VAL") } record(mbbo, "$(P):CH_DISP03") { field(DESC, "Select Channel to display") field(ZRVL, "0") field(ZRST, "1") field(ONVL, "1") field(ONST, "2") field(TWVL, "2") field(TWST, "3") field(THVL, "3") field(THST, "4") field(FRVL, "4") field(FRST, "5") field(FVVL, "5") field(FVST, "6") field(SXVL, "6") field(SXST, "7") field(SVVL, "7") field(SVST, "8") field(EIVL, "8") field(EIST, "9") field(NIVL, "9") field(NIST, "10") field(TEVL, "10") field(TEST, "11") field(ELVL, "11") field(ELST, "12") field(TVVL, "12") field(TVST, "13") field(TTVL, "13") field(TTST, "14") field(FTVL, "14") field(FTST, "15") field(FTVL, "15") field(FTST, "16") field(VAL, "0") field(PINI, "1") info(autosaveFields, "VAL") }