# Empty string used by cryoTestCav.template record(stringin, "$(CM,recursive)00:RFCRYOTEST_SET_FLT_STR") { field(VAL, " ") field(PINI, "YES") } # Indicate fake LLRF data for cryo testing record(bo, "$(CM,recursive)00:RFCRYOTEST_SIM") { field(DESC, "Force cavity 1 test fault") field(ZNAM, "Fake data off") field(ONAM, "Fake data on") field(OSV, "MINOR") field(VAL, "0") field(PINI, "YES") } # Force RF-side faults record(stringout, "$(CM,undefined)10:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 1 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK1 CA") } record(stringin, "$(CM,undefined)10:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)10:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)10:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 1 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)10:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK1 CA") } record(mbbiDirect, "$(CM,undefined)10:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1155_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)20:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 2 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK2 CA") } record(stringin, "$(CM,undefined)20:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)20:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)20:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 2 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)20:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK2 CA") } record(mbbiDirect, "$(CM,undefined)20:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1255_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)30:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 3 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK3 CA") } record(stringin, "$(CM,undefined)30:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)30:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)30:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 3 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)30:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK3 CA") } record(mbbiDirect, "$(CM,undefined)30:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1355_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)40:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 4 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK4 CA") } record(stringin, "$(CM,undefined)40:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)40:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)40:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 4 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)40:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK4 CA") } record(mbbiDirect, "$(CM,undefined)40:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1455_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)50:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 5 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK5 CA") } record(stringin, "$(CM,undefined)50:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)50:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)50:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 5 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)50:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO_.LNK5 CA") } record(mbbiDirect, "$(CM,undefined)50:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1555_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)60:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 6 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO2_.LNK1 CA") } record(stringin, "$(CM,undefined)60:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)60:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)60:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 6 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)60:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO2_.LNK1 CA") } record(mbbiDirect, "$(CM,undefined)60:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1655_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)70:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 7 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO2_.LNK2 CA") } record(stringin, "$(CM,undefined)70:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)70:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)70:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 7 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)70:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO2_.LNK2 CA") } record(mbbiDirect, "$(CM,undefined)70:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1755_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }# Force RF-side faults record(stringout, "$(CM,undefined)80:RFCRYOTEST_SET_FLT") { field(DESC, "Force cavity 8 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)00:RFCRYOTEST_SET_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO2_.LNK3 CA") } record(stringin, "$(CM,undefined)80:RFCRYOTEST_CLR_FLT_STR") { field(VAL, "$(CM,undefined)80:AACT_SQR_RAW") field(PINI, "YES") } record(stringout, "$(CM,undefined)80:RFCRYOTEST_CLR_FLT") { field(DESC, "Clear cavity 8 test fault") field(OMSL, "closed_loop") field(DOL, "$(CM,undefined)80:RFCRYOTEST_CLR_FLT_STR") field(OUT, "$(CM,undefined)00:RFCRYO_SUB_FO2_.LNK3 CA") } record(mbbiDirect, "$(CM,undefined)80:RFCRYOTEST_HBFLT") { field(DESC, "Cryo side cavity heartbeat status") field(SCAN, "1 second") field(DTYP, "EtherIP") # Use E flag because we read single element in large array # and do not want to try to read all lower-indexed elements # Causes read/write errors in some instances $(TEST,recursive) field(INP, "@$(PLC,undefined) CRF_1855_ALARM[$(CMCRYO,undefined)] E B 0") # field(NOBT, "1") }