record(aSub, "$(PREF)ADES_MAX_CALC") { field(DESC, "Amplitude limit") field(SNAM, "max_index") # Starting at A, inputs are values # to find max of field(FTA, "DOUBLE") field(INPA, "$(PREF)ADES_MAX_RF") field(FTB, "DOUBLE") field(INPB, "$(PREF)ADES_MAX_SRF") field(FTC, "DOUBLE") field(INPC, "$(PREF)ADES_MAX_OPS") # VALA max value field(FTVA, "DOUBLE") field(OUTA, "$(PREF)ADES_MAX PP") # VALB index of max value field(FTVB, "LONG") field(OUTB, "$(PREF)ADES_MAX_SRC PP") field(PINI, "YES") } # Slave ADEX_MAX and ADEX_SRC_MAX to # CALC. Use aSub output links to process # them, though, so error in subroutine # results in no change to ADES_MAX record(ao, "$(PREF)ADES_MAX") { field(DESC, "Amplitude limit") field(OMSL, "closed_loop") field(DOL, "$(PREF)ADES_MAX_CALC.VALA MSI") field(VAL, "0") field(DRVL, "0") # initial upper limit of 21 MV/m field(DRVH, "21.798") field(HIHI, "21.798") field(HHSV, "MAJOR") field(LOPR, "0") field(HOPR, "21.798") field(EGU, "MV") field(FLNK, "$(PREF)ADES_MAX_FO") } # String/val order must match # order of inputs in ADES_MAX_CALC record(mbbi, "$(PREF)ADES_MAX_SRC") { field(DESC, "Amplitude limiting factor") field(INP, "$(PREF)ADES_MAX_CALC.VALB MSI") field(VAL, "0") field(ZRVL, "0") field(ZRST, "RF") field(ONVL, "1") field(ONST, "SRF") field(TWVL, "2") field(TWST, "Ops") } record(dfanout, "$(PREF)ADES_MAX_FO") { field(DESC, "Amplitude limit") field(OMSL, "closed_loop") field(DOL, "$(PREF)ADES_MAX MSI") field(OUTA, "$(PREF)ADES.DRVH") field(OUTB, "$(PREF)ADES.HOPR") field(OUTC, "$(PREF)ADES.HIGH") field(OUTD, "$(PREF)ADES.HIHI") } # Optionally set default maximum ADES record(ao, "$(PREF)ADES_MAX_SRF") { field(DESC, "Amplitude limit SRF") field(OMSL, "supervisory") field(VAL, "$(MAX=0)") field(EGU, "MV") field(PINI, "YES") field(FLNK, "$(PREF)ADES_MAX_CALC") info(autosaveFields, "VAL") } record(ao, "$(PREF)ADES_MAX_RF") { field(DESC, "Amplitude limit RF") field(OMSL, "supervisory") field(VAL, "$(MAX=0)") field(EGU, "MV") field(PINI, "YES") field(FLNK, "$(PREF)ADES_MAX_CALC") info(autosaveFields, "VAL") } record(ao, "$(PREF)ADES_MAX_OPS") { field(DESC, "Amplitude limit Ops") field(OMSL, "supervisory") field(VAL, "$(MAX=0)") field(EGU, "MV") field(PINI, "YES") field(FLNK, "$(PREF)ADES_MAX_CALC") info(autosaveFields, "VAL") }