record(ai, "OTRS:LI24:807:RESOLUTION") {
  field(DESC, "resolution")
  field(PINI, "YES")
  field(VAL, "17.09")
  field(EGU,  "um")
  field(PREC, "3")
}

record(bo, "OTRS:LI24:807:SAVE_IMG")
{
  field(DESC, "saveImage")
  field(DTYP, "EDTCL_UP900_12B")
  field(OUT,  "@OTR21:SaveImage")
  field(ZNAM, "FreeRun")
  field(ONAM, "Save")
}

record(longin, "OTRS:LI24:807:N_OF_COL") {
  field(DESC, "n of col")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:NumOfCol")
  field(PINI, "YES")
  field(EGU,  "pixels")
}

record(longin, "OTRS:LI24:807:N_OF_ROW") {
  field(DESC, "n of row")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:NumOfRow")
  field(PINI, "YES")
  field(EGU,  "pixels")
}

record(longin, "OTRS:LI24:807:N_OF_BITS") {
  field(DESC, "n of bits")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:NumOfBits")
  field(PINI, "YES")
  field(EGU,  "bits")
}

record(longin, "OTRS:LI24:807:FRAME_RATE") {
  field(DESC, "frame rate")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:FrameRate")
  field(SCAN, "1 second")
  field(EGU,  "fps")
  field(PHAS, "0")
  field(PINI, "YES")
}

record(longout, "OTRS:LI24:807:ROI_X_SET") {
  field(DESC, "startPixelXSet")
  field(DTYP, "EDTCL_UP900_12B")
  field(OUT,  "@OTR21:StartPixelX")
  field(EGU,  "pixel")
  field(HOPR, "1391")
  field(DRVH, "1391")
  field(LOPR, "0")
  field(DRVL, "0")
  field(FLNK, "OTRS:LI24:807:ROI_X")
}

record(longin, "OTRS:LI24:807:ROI_X") {
  field(DESC, "startPixelXGet")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:StartPixelX")
  field(EGU,  "pixel")
  field(PINI, "YES")
}

record(longout, "OTRS:LI24:807:ROI_Y_SET") {
  field(DESC, "startPixelYSet")
  field(DTYP, "EDTCL_UP900_12B")
  field(OUT,  "@OTR21:StartPixelY")
  field(EGU,  "pixel")
  field(HOPR, "1039")
  field(DRVH, "1039")
  field(LOPR, "0")
  field(DRVL, "0")
  field(FLNK, "OTRS:LI24:807:ROI_Y")
}

record(longin, "OTRS:LI24:807:ROI_Y") {
  field(DESC, "startPixelYGet")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:StartPixelY")
  field(EGU,  "pixel")
  field(PINI, "YES")
}

record(longout, "OTRS:LI24:807:ROI_XNP_SET") {
  field(DESC, "nPixelsXSet")
  field(DTYP, "EDTCL_UP900_12B")
  field(OUT,  "@OTR21:NumPixelsX")
  field(EGU,  "pixels")
  field(HOPR, "1392")
  field(DRVH, "1392")
  field(LOPR, "1")
  field(DRVL, "1")
  field(FLNK, "OTRS:LI24:807:ROI_XNP")
}

record(longin, "OTRS:LI24:807:ROI_XNP") {
  field(DESC, "nPixelsXGet")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:NumPixelsX")
  field(EGU,  "pixels")
  field(PINI, "YES")
}

record(longout, "OTRS:LI24:807:ROI_YNP_SET") {
  field(DESC, "nPixelsYSet")
  field(DTYP, "EDTCL_UP900_12B")
  field(OUT,  "@OTR21:NumPixelsY")
  field(EGU,  "pixels")
  field(HOPR, "1040")
  field(DRVH, "1040")
  field(LOPR, "1")
  field(DRVL, "1")
  field(FLNK, "OTRS:LI24:807:ROI_YNP")
}

record(longin, "OTRS:LI24:807:ROI_YNP") {
  field(DESC, "nPixelsYGet")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:NumPixelsY")
  field(EGU,  "pixels")
  field(PINI, "YES")
}

record(waveform, "OTRS:LI24:807:IMAGE") {
  field(DESC, "Image")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:CurImage")
  field(TSE,  "-2")
#  field(TSE,  "213")
  field(FTVL, "USHORT")
  field(NELM, "1447680")
  field(EGU,  "units")
  field(SCAN, "1 second")
  field(PHAS, "2")
  info(autosaveFields, "TSE")
}

record(longout, "OTRS:LI24:807:IMG_BUF_IDX") {
  field(DESC, "hisImageIndex")
  field(DTYP, "EDTCL_UP900_12B")
  field(OUT,  "@OTR21:HisIndex")
  field(FLNK, "OTRS:LI24:807:BUFD_IMG")
}

record(waveform, "OTRS:LI24:807:BUFD_IMG") {
  field(DESC, "Image")
  field(DTYP, "EDTCL_UP900_12B")
  field(INP,  "@OTR21:HisImage")
  field(TSE,  "-2")
  field(FTVL, "USHORT")
  field(NELM, "1447680")
  field(EGU,  "units")
}

record(bi, "OTRS:LI24:807:X_ORIENT")
{
  field(DESC, "Image X Orient")
  field(VAL,  "1")
  field(PINI, "YES")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
}

record(bi, "OTRS:LI24:807:Y_ORIENT")
{
  field(DESC, "Image Y Orient")
  field(VAL,  "1")
  field(PINI, "YES")
  field(ZNAM, "Positive")
  field(ONAM, "Negative")
}

record(ai, "OTRS:LI24:807:X_BM_CTR") {
  field(DESC, "X beam center")
  field(VAL, "0")
  field(EGU,  "mm")
  field(PREC, "5")
  field(PINI, "YES")
}

record(ai, "OTRS:LI24:807:Y_BM_CTR") {
  field(DESC, "Y beam center")
  field(VAL, "0")
  field(EGU,  "mm")
  field(PREC, "5")
  field(PINI, "YES")
}

record(ai, "OTRS:LI24:807:X_AM_CTR") {
  field(DESC, "X alignment center")
  field(VAL, "0")
  field(EGU,  "mm")
  field(PREC, "5")
  field(PINI, "YES")
}

record(ai, "OTRS:LI24:807:Y_AM_CTR") {
  field(DESC, "Y alignment center")
  field(VAL, "0")
  field(EGU,  "mm")
  field(PREC, "5")
  field(PINI, "YES")
}

record(ai, "OTRS:LI24:807:X_RTCL_CTR") {
  field(DESC, "X reticle center")
  field(VAL, "734")
  field(PINI, "YES")
  field(EGU,  "pixels")
  field(PREC, "2")
}

record(ai, "OTRS:LI24:807:Y_RTCL_CTR") {
  field(DESC, "Y reticle center")
  field(VAL, "536")
  field(PINI, "YES")
  field(EGU,  "pixels")
  field(PREC, "2")
}

###### Profile Monitor One ########
record(bo, OTRS:LI24:807:PNEUMATIC) {
  field(DESC, "pneumatic target")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B0")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
  field(PINI, "YES")
}


# CALC to increment counter by 1 everytime button is released
record(calcout, OTRS:LI24:807:PNEU_CALC_CNT) {
  field(DESC, "Increment PNEU count CALC")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(INPA, "OTRS:LI24:807:PNEUMATIC CP")
  field(INPB, "OTRS:LI24:807:PNEU_CNT.VAL")
  field(CALC, "A")
  field(OUT, "OTRS:LI24:807:PNEU_CNT.VAL PP")
  field(OOPT, "Transition To Zero")
  field(DOPT, "Use OCAL")
  field(OCAL, "B+1")
}

# Stores the button pressed count
record(ai, OTRS:LI24:807:PNEU_CNT) {
  field(DESC, "OTRS:LI24:807 Pneu Counter")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(VAL, "0")
  info(autosaveFields, "VAL")
}

# Fanout for (1) Timestamp, (2) Reset Count
record(fanout, "OTRS:LI24:807:RST_FANOUT") {
  field(DESC, "Handle timestamp and counter reset")
  field(LNK1, "OTRS:LI24:807:RST_TS_TRIG")
  field(LNK2, "OTRS:LI24:807:RST_AO")
  field(LNK3, "OTRS:LI24:807:PNEU_CNT")
}

# Triggers timestamp record
record(stringin, "OTRS:LI24:807:RST_TS_TRIG") {
  field(DESC, "triggers timestamp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "OTRS:LI24:807:RST_TS")
}

# Stores timestamp
record(stringin, "OTRS:LI24:807:RST_TS") {
  field(DESC, "Reset timestamp")
  field(INP, "OTRS:LI24:807:RST_TS_TRIG")
  field(PINI, "YES")
}

# Resets button count to zero
record(ao, "OTRS:LI24:807:RST_AO") {
  field(DESC, "Write 0 to count")
  field(VAL, "0")
  field(OUT, "OTRS:LI24:807:PNEU_CNT")
  field(OMSL, "supervisory")
}

record(stringin, "OTRS:LI24:807:REPL_TS_TRIG") {
  field(DESC, "triggers repl tmstmp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "OTRS:LI24:807:REPL_TS")
}

# Replacement timestamp
record(stringin, "OTRS:LI24:807:REPL_TS") {
  field(DESC, "Timestamp device replacement")
  field(INP, "OTRS:LI24:807:REPL_TS_TRIG")
  field(PINI, "YES")
}


record(bi, OTRS:LI24:807:IN_LMTSW) {
  field(DESC, "pneumatic target In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B0")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(OSV,  "MINOR")
  field(FLNK,"OTRS:LI24:807:OUT_LMTSW")
}

record(bi, OTRS:LI24:807:OUT_LMTSW) {
  field(DESC, "pneumatic target Out")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B1")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(ZSV,  "MINOR")
  field(FLNK,"OTRS:LI24:807:TgtStsCalc")
}

record(calc, OTRS:LI24:807:TgtStsCalc) {
  field(INPA,"OTRS:LI24:807:IN_LMTSW")
  field(INPB,"OTRS:LI24:807:OUT_LMTSW")
  field(CALC,"A*2+B")
  field(FLNK,"OTRS:LI24:807:TGT_STS")
}

record(mbbi, "OTRS:LI24:807:TGT_STS")
{
  field(DESC, "Target Status")
  field(INP,  "OTRS:LI24:807:TgtStsCalc")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bo, OTRS:LI24:807:FLT1_PNEU) {
  field(DESC, "Filter 1")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B1")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, OTRS:LI24:807:FLT1_IN) {
  field(DESC, "Filter 1 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B2")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, OTRS:LI24:807:FLT1_OUT) {
  field(DESC, "Filter 1 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B3")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bo, OTRS:LI24:807:FLT2_PNEU) {
  field(DESC, "Filter 2")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B2")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, OTRS:LI24:807:FLT2_IN) {
  field(DESC, "Filter 2 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B4")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, OTRS:LI24:807:FLT2_OUT) {
  field(DESC, "Filter 2 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B5")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(calc, "OTRS:LI24:807:FLT1_STS_CALC") {
  field(DESC, "Filter 1 Status Calc (Ch 1)")
  field(INPA,"OTRS:LI24:807:FLT1_IN.RVAL")
  field(INPB,"OTRS:LI24:807:FLT1_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"OTRS:LI24:807:FLT1_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "OTRS:LI24:807:FLT1_STS") {
  field(DESC, "Filter 1 Status (Ch 1)")
  field(INP,  "OTRS:LI24:807:FLT1_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(calc, "OTRS:LI24:807:FLT2_STS_CALC") {
  field(DESC, "Filter 2 Status Calc (Ch 1)")
  field(INPA,"OTRS:LI24:807:FLT2_IN.RVAL")
  field(INPB,"OTRS:LI24:807:FLT2_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"OTRS:LI24:807:FLT2_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "OTRS:LI24:807:FLT2_STS") {
  field(DESC, "Filter 2 Status (Ch 1)")
  field(INP,  "OTRS:LI24:807:FLT2_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bi, OTRS:LI24:807:SOLENOID_ERR) {
  field(DESC, "Solenoid Err")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P0 B6")
  field(ZNAM, "Ok")
  field(ONAM, "Error")
}

###### Profile Monitor Two ########
record(bo, SPR:LI24:003:PNEUMATIC) {
  field(DESC, "pneumatic target")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B3")
  field(ZNAM, "INSERT")
  field(ONAM, "RETRACT")
  field(PINI, "YES")
}


# CALC to increment counter by 1 everytime button is released
record(calcout, SPR:LI24:003:PNEU_CALC_CNT) {
  field(DESC, "Increment PNEU count CALC")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(INPA, "SPR:LI24:003:PNEUMATIC CP")
  field(INPB, "SPR:LI24:003:PNEU_CNT.VAL")
  field(CALC, "A")
  field(OUT, "SPR:LI24:003:PNEU_CNT.VAL PP")
  field(OOPT, "Transition To Non-zero")
  field(DOPT, "Use OCAL")
  field(OCAL, "B+1")
}

# Stores the button pressed count
record(ai, SPR:LI24:003:PNEU_CNT) {
  field(DESC, "SPR:LI24:003 Pneu Counter")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(VAL, "0")
  info(autosaveFields, "VAL")
}

# Fanout for (1) Timestamp, (2) Reset Count
record(fanout, "SPR:LI24:003:RST_FANOUT") {
  field(DESC, "Handle timestamp and counter reset")
  field(LNK1, "SPR:LI24:003:RST_TS_TRIG")
  field(LNK2, "SPR:LI24:003:RST_AO")
  field(LNK3, "SPR:LI24:003:PNEU_CNT")
}

# Triggers timestamp record
record(stringin, "SPR:LI24:003:RST_TS_TRIG") {
  field(DESC, "triggers timestamp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "SPR:LI24:003:RST_TS")
}

# Stores timestamp
record(stringin, "SPR:LI24:003:RST_TS") {
  field(DESC, "Reset timestamp")
  field(INP, "SPR:LI24:003:RST_TS_TRIG")
  field(PINI, "YES")
}

# Resets button count to zero
record(ao, "SPR:LI24:003:RST_AO") {
  field(DESC, "Write 0 to count")
  field(VAL, "0")
  field(OUT, "SPR:LI24:003:PNEU_CNT")
  field(OMSL, "supervisory")
}

record(stringin, "SPR:LI24:003:REPL_TS_TRIG") {
  field(DESC, "triggers repl tmstmp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "SPR:LI24:003:REPL_TS")
}

# Replacement timestamp
record(stringin, "SPR:LI24:003:REPL_TS") {
  field(DESC, "Timestamp device replacement")
  field(INP, "SPR:LI24:003:REPL_TS_TRIG")
  field(PINI, "YES")
}


record(bi, SPR:LI24:003:IN_LMTSW) {
  field(DESC, "pneumatic target In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B0")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(OSV,  "MINOR")
  field(FLNK,"SPR:LI24:003:OUT_LMTSW")
}

record(bi, SPR:LI24:003:OUT_LMTSW) {
  field(DESC, "pneumatic target Out")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B1")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(ZSV,  "MINOR")
  field(FLNK,"SPR:LI24:003:TgtStsCalc")
}

record(calc, SPR:LI24:003:TgtStsCalc) {
  field(INPA,"SPR:LI24:003:IN_LMTSW")
  field(INPB,"SPR:LI24:003:OUT_LMTSW")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:003:TGT_STS")
}

record(mbbi, "SPR:LI24:003:TGT_STS")
{
  field(DESC, "Target Status")
  field(INP,  "SPR:LI24:003:TgtStsCalc")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bo, SPR:LI24:003:FLT1_PNEU) {
  field(DESC, "Filter 1")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B4")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, SPR:LI24:003:FLT1_IN) {
  field(DESC, "Filter 1 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B2")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, SPR:LI24:003:FLT1_OUT) {
  field(DESC, "Filter 1 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B3")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bo, SPR:LI24:003:FLT2_PNEU) {
  field(DESC, "Filter 2")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B5")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, SPR:LI24:003:FLT2_IN) {
  field(DESC, "Filter 2 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B4")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, SPR:LI24:003:FLT2_OUT) {
  field(DESC, "Filter 2 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B5")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(calc, "SPR:LI24:003:FLT1_STS_CALC") {
  field(DESC, "Filter 1 Status Calc (Ch 2)")
  field(INPA,"SPR:LI24:003:FLT1_IN.RVAL")
  field(INPB,"SPR:LI24:003:FLT1_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:003:FLT1_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "SPR:LI24:003:FLT1_STS") {
  field(DESC, "Filter 1 Status (Ch 2)")
  field(INP,  "SPR:LI24:003:FLT1_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(calc, "SPR:LI24:003:FLT2_STS_CALC") {
  field(DESC, "Filter 2 Status Calc (Ch 2)")
  field(INPA,"SPR:LI24:003:FLT2_IN.RVAL")
  field(INPB,"SPR:LI24:003:FLT2_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:003:FLT2_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "SPR:LI24:003:FLT2_STS") {
  field(DESC, "Filter 2 Status (Ch 2)")
  field(INP,  "SPR:LI24:003:FLT2_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}


record(bi, SPR:LI24:003:SOLENOID_ERR) {
  field(DESC, "Solenoid Err")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P1 B6")
  field(ZNAM, "Ok")
  field(ONAM, "Error")
}

###### Profile Monitor Three ########
record(bo, SPR:LI24:001:PNEUMATIC) {
  field(DESC, "pneumatic target")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B6")
  field(ZNAM, "INSERT")
  field(ONAM, "RETRACT")
  field(PINI, "YES")
}

# CALC to increment counter by 1 everytime button is released
record(calcout, SPR:LI24:001:PNEU_CALC_CNT) {
  field(DESC, "Increment PNEU count CALC")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(INPA, "SPR:LI24:001:PNEUMATIC CP")
  field(INPB, "SPR:LI24:001:PNEU_CNT.VAL")
  field(CALC, "A")
  field(OUT, "SPR:LI24:001:PNEU_CNT.VAL PP")
  field(OOPT, "Transition To Non-zero")
  field(DOPT, "Use OCAL")
  field(OCAL, "B+1")
}

# Stores the button pressed count
record(ai, SPR:LI24:001:PNEU_CNT) {
  field(DESC, "SPR:LI24:001 Pneu Counter")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(VAL, "0")
  info(autosaveFields, "VAL")
}

# Fanout for (1) Timestamp, (2) Reset Count
record(fanout, "SPR:LI24:001:RST_FANOUT") {
  field(DESC, "Handle timestamp and counter reset")
  field(LNK1, "SPR:LI24:001:RST_TS_TRIG")
  field(LNK2, "SPR:LI24:001:RST_AO")
  field(LNK3, "SPR:LI24:001:PNEU_CNT")
}

# Triggers timestamp record
record(stringin, "SPR:LI24:001:RST_TS_TRIG") {
  field(DESC, "triggers timestamp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "SPR:LI24:001:RST_TS")
}

# Stores timestamp
record(stringin, "SPR:LI24:001:RST_TS") {
  field(DESC, "Reset timestamp")
  field(INP, "SPR:LI24:001:RST_TS_TRIG")
  field(PINI, "YES")
}

# Resets button count to zero
record(ao, "SPR:LI24:001:RST_AO") {
  field(DESC, "Write 0 to count")
  field(VAL, "0")
  field(OUT, "SPR:LI24:001:PNEU_CNT")
  field(OMSL, "supervisory")
}

record(stringin, "SPR:LI24:001:REPL_TS_TRIG") {
  field(DESC, "triggers repl tmstmp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "SPR:LI24:001:REPL_TS")
}

# Replacement timestamp
record(stringin, "SPR:LI24:001:REPL_TS") {
  field(DESC, "Timestamp device replacement")
  field(INP, "SPR:LI24:001:REPL_TS_TRIG")
  field(PINI, "YES")
}


record(bi, SPR:LI24:001:IN_LMTSW) {
  field(DESC, "pneumatic target In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B0")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(OSV,  "MINOR")
  field(FLNK,"SPR:LI24:001:OUT_LMTSW")
}

record(bi, SPR:LI24:001:OUT_LMTSW) {
  field(DESC, "pneumatic target Out")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B1")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(ZSV,  "MINOR")
  field(FLNK,"SPR:LI24:001:TgtStsCalc")
}

record(calc, SPR:LI24:001:TgtStsCalc) {
  field(INPA,"SPR:LI24:001:IN_LMTSW")
  field(INPB,"SPR:LI24:001:OUT_LMTSW")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:001:TGT_STS")
}

record(mbbi, "SPR:LI24:001:TGT_STS")
{
  field(DESC, "Target Status")
  field(INP,  "SPR:LI24:001:TgtStsCalc")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bo, SPR:LI24:001:FLT1_PNEU) {
  field(DESC, "Filter 1")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P0 B7")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, SPR:LI24:001:FLT1_IN) {
  field(DESC, "Filter 1 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B2")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, SPR:LI24:001:FLT1_OUT) {
  field(DESC, "Filter 1 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B3")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bo, SPR:LI24:001:FLT2_PNEU) {
  field(DESC, "Filter 2")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B0")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, SPR:LI24:001:FLT2_IN) {
  field(DESC, "Filter 2 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B4")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, SPR:LI24:001:FLT2_OUT) {
  field(DESC, "Filter 2 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B5")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(calc, "SPR:LI24:001:FLT1_STS_CALC") {
  field(DESC, "Filter 1 Status Calc (Ch 3)")
  field(INPA,"SPR:LI24:001:FLT1_IN.RVAL")
  field(INPB,"SPR:LI24:001:FLT1_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:001:FLT1_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "SPR:LI24:001:FLT1_STS") {
  field(DESC, "Filter 1 Status (Ch 3)")
  field(INP,  "SPR:LI24:001:FLT1_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(calc, "SPR:LI24:001:FLT2_STS_CALC") {
  field(DESC, "Filter 2 Status Calc (Ch 3)")
  field(INPA,"SPR:LI24:001:FLT2_IN.RVAL")
  field(INPB,"SPR:LI24:001:FLT2_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:001:FLT2_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "SPR:LI24:001:FLT2_STS") {
  field(DESC, "Filter 2 Status (Ch 3)")
  field(INP,  "SPR:LI24:001:FLT2_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bi, SPR:LI24:001:SOLENOID_ERR) {
  field(DESC, "Solenoid Err")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P2 B6")
  field(ZNAM, "Ok")
  field(ONAM, "Error")
}

###### Profile Monitor Four ########
record(bo, SPR:LI24:002:PNEUMATIC) {
  field(DESC, "pneumatic target")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B1")
  field(ZNAM, "INSERT")
  field(ONAM, "RETRACT")
  field(PINI, "YES")
}

# CALC to increment counter by 1 everytime button is released
record(calcout, SPR:LI24:002:PNEU_CALC_CNT) {
  field(DESC, "Increment PNEU count CALC")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(INPA, "SPR:LI24:002:PNEUMATIC CP")
  field(INPB, "SPR:LI24:002:PNEU_CNT")
  field(CALC, "A")
  field(OUT, "SPR:LI24:002:PNEU_CNT.VAL PP")
  field(OOPT, "Transition To Non-zero")
  field(DOPT, "Use OCAL")
  field(OCAL, "B+1")
}

# Stores the button pressed count
record(ai, SPR:LI24:002:PNEU_CNT) {
  field(DESC, "SPR:LI24:002 Pneu Counter")
  field(SCAN, "Passive")
  field(VAL, "0")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}

# Fanout for (1) Timestamp, (2) Reset Count
record(fanout, "SPR:LI24:002:RST_FANOUT") {
  field(DESC, "Handle timestamp and counter reset")
  field(LNK1, "SPR:LI24:002:RST_TS_TRIG")
  field(LNK2, "SPR:LI24:002:RST_AO")
  field(LNK3, "SPR:LI24:002:PNEU_CNT")
}

# Triggers timestamp record
record(stringin, "SPR:LI24:002:RST_TS_TRIG") {
  field(DESC, "triggers timestamp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "SPR:LI24:002:RST_TS")
}

# Stores timestamp
record(stringin, "SPR:LI24:002:RST_TS") {
  field(DESC, "Reset timestamp")
  field(INP, "SPR:LI24:002:RST_TS_TRIG")
  field(PINI, "YES")
}

# Resets button count to zero
record(ao, "SPR:LI24:002:RST_AO") {
  field(DESC, "Write 0 to count")
  field(VAL, "0")
  field(OUT, "SPR:LI24:002:PNEU_CNT")
  field(OMSL, "supervisory")
}

record(stringin, "SPR:LI24:002:REPL_TS_TRIG") {
  field(DESC, "triggers repl tmstmp record")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%Y %H:%M:%S")
  field(SCAN, "Passive")
  info(autosaveFields, "VAL")
  field(FLNK, "SPR:LI24:002:REPL_TS")
}

# Replacement timestamp
record(stringin, "SPR:LI24:002:REPL_TS") {
  field(DESC, "Timestamp device replacement")
  field(INP, "SPR:LI24:002:REPL_TS_TRIG")
  field(PINI, "YES")
}


record(bi, SPR:LI24:002:IN_LMTSW) {
  field(DESC, "pneumatic target In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B0")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(OSV,  "MINOR")
  field(FLNK,"SPR:LI24:002:OUT_LMTSW")
}

record(bi, SPR:LI24:002:OUT_LMTSW) {
  field(DESC, "pneumatic target Out")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B1")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
  field(ZSV,  "MINOR")
  field(FLNK,"SPR:LI24:002:TgtStsCalc")
}

record(calc, SPR:LI24:002:TgtStsCalc) {
  field(INPA,"SPR:LI24:002:IN_LMTSW")
  field(INPB,"SPR:LI24:002:OUT_LMTSW")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:002:TGT_STS")
}

record(mbbi, "SPR:LI24:002:TGT_STS")
{
  field(DESC, "Target Status")
  field(INP,  "SPR:LI24:002:TgtStsCalc")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bo, SPR:LI24:002:FLT1_PNEU) {
  field(DESC, "Filter 1")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B2")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, SPR:LI24:002:FLT1_IN) {
  field(DESC, "Filter 1 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B2")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, SPR:LI24:002:FLT1_OUT) {
  field(DESC, "Filter 1 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B3")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bo, SPR:LI24:002:FLT2_PNEU) {
  field(DESC, "Filter 2")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B3")
  field(ZNAM, "OUT")
  field(ONAM, "IN")
}

record(bi, SPR:LI24:002:FLT2_IN) {
  field(DESC, "Filter 2 In")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B4")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(bi, SPR:LI24:002:FLT2_OUT) {
  field(DESC, "Filter 2 Out")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B5")
  field(ZNAM, "Inactive")
  field(ONAM, "Active")
}

record(calc, "SPR:LI24:002:FLT1_STS_CALC") {
  field(DESC, "Filter 1 Status Calc (Ch 4)")
  field(INPA,"SPR:LI24:002:FLT1_IN.RVAL")
  field(INPB,"SPR:LI24:002:FLT1_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:002:FLT1_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "SPR:LI24:002:FLT1_STS") {
  field(DESC, "Filter 1 Status (Ch 4)")
  field(INP,  "SPR:LI24:002:FLT1_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(calc, "SPR:LI24:002:FLT2_STS_CALC") {
  field(DESC, "Filter 2 Status Calc (Ch 4)")
  field(INPA,"SPR:LI24:002:FLT2_IN.RVAL")
  field(INPB,"SPR:LI24:002:FLT2_OUT.RVAL")
  field(CALC,"A*2+B")
  field(FLNK,"SPR:LI24:002:FLT2_STS")
	field(SCAN, ".1 second")
}

record(mbbi, "SPR:LI24:002:FLT2_STS") {
  field(DESC, "Filter 2 Status (Ch 4)")
  field(INP,  "SPR:LI24:002:FLT2_STS_CALC")

  field(ZRVL,"0")
  field(ZRST,"MOVING")
  field(ZRSV,"MAJOR")

  field(ONVL,"1")
  field(ONST,"OUT")
  field(ONSV,"NO_ALARM")

  field(TWVL,"2")
  field(TWST,"IN")
  field(TWSV,"MINOR")

  field(THVL,"3")
  field(THST,"INCONSISTENT")
  field(THSV,"MAJOR")
}

record(bi, SPR:LI24:002:SOLENOID_ERR) {
  field(DESC, "Solenoid Err")
  field(SCAN, ".1 second")
  field(DTYP, "XYCOM-2440")
  field(INP, "@bi0 P3 B6")
  field(ZNAM, "Ok")
  field(ONAM, "Error")
}

######### Group Lamp ############
record(mbbo, "PFMC:LI24:GP01:LAMP_CH") {
  field(DESC, "Lamp Ch Select")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(ZRST, "OTR21")
  field(ONST, "SPARE")
  field(TWST, "SPARE")
  field(THST, "SPARE")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(FLNK, "PFMC:LI24:GP01:LAMP_CH_BITS")
}

record(mbbiDirect, "PFMC:LI24:GP01:LAMP_CH_BITS") {
  field(DESC, "Lamp Ch Bits")
  field(INP,  "PFMC:LI24:GP01:LAMP_CH")
  field(FLNK, "PFMC:LI24:GP01:LAMP_CH_B0")
}

record(bo, PFMC:LI24:GP01:LAMP_CH_B0) {
  field(DESC, "Lamp Ch B0")
  field(DOL,  "PFMC:LI24:GP01:LAMP_CH_BITS.B0")
  field(OMSL, "closed_loop")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B4")
  field(ZNAM, "0")
  field(ONAM, "1")
  field(FLNK, "PFMC:LI24:GP01:LAMP_CH_B1")
}

record(bo, PFMC:LI24:GP01:LAMP_CH_B1) {
  field(DESC, "Lamp Ch B1")
  field(DOL,  "PFMC:LI24:GP01:LAMP_CH_BITS.B1")
  field(OMSL, "closed_loop")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B5")
  field(ZNAM, "0")
  field(ONAM, "1")
}

record(bo, PFMC:LI24:GP01:T_LAMP_ENA) {
  field(DESC, "T Lamp Ena")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B6")
  field(ZNAM, "Disable")
  field(ONAM, "Enable")
}

record(bo, PFMC:LI24:GP01:G_LAMP_ENA) {
  field(DESC, "G Lamp Ena")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P1 B7")
  field(ZNAM, "Disable")
  field(ONAM, "Enable")
}

record(bo, PFMC:LI24:GP01:T_LAMP_UP) {
  field(DESC, "T Lamp brighter")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B0")
  field(ZNAM, "--------")
  field(ONAM, "Brighter")
}

record(bo, PFMC:LI24:GP01:T_LAMP_DOWN) {
  field(DESC, "T Lamp dimmer")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B1")
  field(ZNAM, "--------")
  field(ONAM, "Dimmer")
}

record(bo, PFMC:LI24:GP01:G_LAMP_UP) {
  field(DESC, "G Lamp brighter")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B2")
  field(ZNAM, "--------")
  field(ONAM, "Brighter")
}

record(bo, PFMC:LI24:GP01:G_LAMP_DOWN) {
  field(DESC, "G Lamp dimmer")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B3")
  field(ZNAM, "--------")
  field(ONAM, "Dimmer")
}

######### Group Lens ############
record(mbbo, "PFMC:LI24:GP01:LENS_CH") {
  field(DESC, "Lens Ch Select")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(ZRST, "OTR21")
  field(ONST, "SPARE")
  field(TWST, "SPARE")
  field(THST, "SPARE")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(FLNK, "PFMC:LI24:GP01:LENS_CH_BITS")
}

record(mbbiDirect, "PFMC:LI24:GP01:LENS_CH_BITS") {
  field(DESC, "Lens Ch Bits")
  field(INP,  "PFMC:LI24:GP01:LENS_CH")
  field(FLNK, "PFMC:LI24:GP01:LENS_CH_B0")
}

record(bo, PFMC:LI24:GP01:LENS_CH_B0) {
  field(DESC, "Lens Ch B0")
  field(DOL,  "PFMC:LI24:GP01:LENS_CH_BITS.B0")
  field(OMSL, "closed_loop")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B4")
  field(ZNAM, "0")
  field(ONAM, "1")
  field(FLNK, "PFMC:LI24:GP01:LENS_CH_B1")
}

record(bo, PFMC:LI24:GP01:LENS_CH_B1) {
  field(DESC, "Lens Ch B1")
  field(DOL,  "PFMC:LI24:GP01:LENS_CH_BITS.B1")
  field(OMSL, "closed_loop")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B5")
  field(ZNAM, "0")
  field(ONAM, "1")
}

record(mbbo, "PFMC:LI24:GP01:IFZ_FUNC") {
  field(DESC, "Iris Focus Zoom Select")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(ZRST, "------")
  field(ONST, "Iris")
  field(TWST, "Focus")
  field(THST, "Zoom")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(FLNK, "PFMC:LI24:GP01:IFZ_FUNC_BITS")
}

record(mbbiDirect, "PFMC:LI24:GP01:IFZ_FUNC_BITS") {
  field(DESC, "IFZ Select Bits")
  field(INP,  "PFMC:LI24:GP01:IFZ_FUNC")
  field(FLNK, "PFMC:LI24:GP01:IFZ_FUNC_B0")
}

record(bo, PFMC:LI24:GP01:IFZ_FUNC_B0) {
  field(DESC, "Iris Focus Zoom B0")
  field(DOL,  "PFMC:LI24:GP01:IFZ_FUNC_BITS.B0")
  field(OMSL, "closed_loop")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B6")
  field(ZNAM, "0")
  field(ONAM, "1")
  field(FLNK, "PFMC:LI24:GP01:IFZ_FUNC_B1")
}

record(bo, PFMC:LI24:GP01:IFZ_FUNC_B1) {
  field(DESC, "Iris Focus Zoom B1")
  field(DOL,  "PFMC:LI24:GP01:IFZ_FUNC_BITS.B1")
  field(OMSL, "closed_loop")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P2 B7")
  field(ZNAM, "0")
  field(ONAM, "1")
}

record(bo, PFMC:LI24:GP01:IFZ_IN) {
  field(DESC, "IFZ Adjust In")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P3 B0")
  field(ZNAM, "---")
  field(ONAM, "IN")
}

record(bo, PFMC:LI24:GP01:IFZ_OUT) {
  field(DESC, "IFZ Adjust Out")
  field(DTYP, "XYCOM-2445")
  field(OUT, "@bo0 P3 B1")
  field(ZNAM, "---")
  field(ONAM, "OUT")
}

record(mbbo, "OTRS:LI24:807:CAMTYPE") {
  field(DESC, "Camera Selector")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(ZRST, "None")
  field(ONST, "OPAL1000")
  field(TWST, "Uniq900CL")
  field(THST, "Manta146b")
  field(FRST, "Uniq900CL VME")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(VAL, "4")
  info(autosaveFields, "VAL")
}

record(mbbo, "SPR:LI24:003:CAMTYPE") {
  field(DESC, "Camera Selector")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(ZRST, "None")
  field(ONST, "OPAL1000")
  field(TWST, "Uniq900CL")
  field(THST, "Manta146b")
  field(FRST, "Uniq900CL VME")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(VAL, "4")
  info(autosaveFields, "VAL")
}

record(mbbo, "SPR:LI24:001:CAMTYPE") {
  field(DESC, "Camera Selector")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(ZRST, "None")
  field(ONST, "OPAL1000")
  field(TWST, "Uniq900CL")
  field(THST, "Manta146b")
  field(FRST, "Uniq900CL VME")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(VAL, "4")
  info(autosaveFields, "VAL")
}

record(mbbo, "SPR:LI24:002:CAMTYPE") {
  field(DESC, "Camera Selector")
  field(SCAN, "Passive")
  field(PINI, "YES")
  field(DTYP, "Soft Channel")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(FRVL, "4")
  field(ZRST, "None")
  field(ONST, "OPAL1000")
  field(TWST, "Uniq900CL")
  field(THST, "Manta146b")
  field(FRST, "Uniq900CL VME")
  field(DOL,  "0")
  field(SHFT, "0")
  field(UNSV, "INVALID")
  field(VAL, "4")
  info(autosaveFields, "VAL")
}
record(er, "EVR:LI24:PM01:CTRL") {
  field(DESC, "EVR:LI24:PM01 Control")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(PINI, "YES")
  field(ENAB, "YES")
  field(PRES, "1")
  field(FPS0, "0")
  field(FPS1, "1")
  field(FPS2, "2")
  field(FPS3, "3")
  field(TRG0, "Enabled")
  field(TRG1, "Enabled")
  field(TRG2, "Enabled")
  field(TRG3, "Enabled")
  field(TRG4, "Enabled")
  field(TRG5, "Enabled")
  field(TRG6, "Enabled")
  field(OTP0, "Enabled")
  field(OTP1, "Enabled")
  field(OTP2, "Enabled")
  field(OTP3, "Enabled")
  field(OTP4, "Enabled")
  field(OTP5, "Enabled")
  field(OTP6, "Enabled")
  field(OTP7, "Enabled")
  field(OTP8, "Enabled")
  field(OTP9, "Enabled")
  field(OTPA, "Enabled")
  field(OTPB, "Enabled")
  field(OTPC, "Enabled")
  field(OTPD, "Enabled")
  field(OT0W, "12")
  field(OT1W, "12")
  field(OT2W, "12")
  field(OT3W, "12")
  field(OT4W, "12")
  field(OT5W, "12")
  field(OT6W, "12")
  field(OT7W, "12")
  field(OT8W, "12")
  field(OT9W, "12")
  field(OTAW, "12")
  field(OTBW, "12")
  field(OTCW, "12")
  field(OTDW, "12")
  field(OT0D, "0")
  field(OT1D, "0")
  field(OT2D, "0")
  field(OT3D, "0")
  field(OT4D, "0")
  field(OT5D, "0")
  field(OT6D, "0")
  field(OT7D, "0")
  field(OT8D, "0")
  field(OT9D, "0")
  field(OTAD, "0")
  field(OTBD, "0")
  field(OTCD, "0")
  field(OTDD, "0")
#Extended Delay Triggers
  field(DG0E, "Disabled")
  field(DG1E, "Disabled")
  field(DG2E, "Disabled")
  field(DG3E, "Disabled")
  field(DG0W, "1000")
  field(DG1W, "1000")
  field(DG2W, "1000")
  field(DG3W, "12")
  field(DG0D, "500")
  field(DG1D, "500")
  field(DG2D, "500")
  field(DG3D, "0")
  field(DG0C, "1")
  field(DG1C, "1")
  field(DG2C, "1")
  field(DG3C, "1")
  field(DG0P, "Inverted")
  field(DG1P, "Inverted")
  field(DG2P, "Inverted")
  field(DG3P, "Normal")
}
record(bi, "EVR:LI24:PM01:LINK") {
  field(DESC, "EVR:LI24:PM01 Link Status")
  field(DTYP, "MRF Event Receiver")
  field(INP,  "#C0 S0 @")
  field(PINI, "YES")
  field(SCAN, "2 second")
  field(ZSV, "MAJOR")
  field(ZNAM, "OFF")
  field(ONAM, "ON")
}
record(ai, "EVR:LI24:PM01:LINKERRCNT") {
  field(DESC, "EVR:LI24:PM01 Link Errors")
  field(INP, "EVR:LI24:PM01:CTRL.TAXI MS")
  field(SCAN, "2 second")
}
record(calc, "EVR:LI24:PM01:LINKERR") {
  field(DESC, "EVR Recent Link Errors")
  field(INPA, "EVR:LI24:PM01:LINKERRCNT MS")
  field(INPB, "EVR:LI24:PM01:LINKERR.LA")
  field(SCAN, "2 second")
  field(CALC, "A<B?A:A-B")
  field(HIHI, "2")
  field(HIGH, "1")
  field(HHSV, "MAJOR")
  field(HSV,  "MINOR")
}
record(bo, "EVR:LI24:PM01:LINKERRRST") {
  field(DESC, "EVR Err Count Reset")
  field(OUT, "EVR:LI24:PM01:CTRL.RXVR PP")
  field(PINI, "YES")
  field(DOL, "1")
  field(OMSL, "closed_loop")
  field(ZNAM, "NoReset")
  field(ONAM, "Reset")
  field(FLNK, "EVR:LI24:PM01:LINKERRRSTTOD")
}
record(stringin, "EVR:LI24:PM01:LINKERRRSTTOD") {
  field(DESC, "EVR Err Count Reset Time")
  field(DTYP, "Soft Timestamp")
  field(INP, "@%m/%d/%y %H:%M:%S")
}
record(erevent, "EVR:LI24:PM01:EVENT1CTRL") {
  field(DESC, "EVENT1 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "141")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT1CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT1RATE") {
  field(DESC, "EVENT1 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT1CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT1EVDESC") {
  field(DESC, "EVENT1 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT1CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT1DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT1DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT1DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT2CTRL") {
  field(DESC, "EVENT2 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "142")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT2CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT2RATE") {
  field(DESC, "EVENT2 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT2CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT2EVDESC") {
  field(DESC, "EVENT2 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT2CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT2DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT2DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT2DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT3CTRL") {
  field(DESC, "EVENT3 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "143")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT3CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT3RATE") {
  field(DESC, "EVENT3 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT3CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT3EVDESC") {
  field(DESC, "EVENT3 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT3CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT3DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT3DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT3DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT4CTRL") {
  field(DESC, "EVENT4 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "159")
  field(OUT0, "1")
  field(OUT1, "1")
  field(OUT2, "1")
  field(OUT3, "1")
  field(OUT4, "1")
  field(OUT5, "1")
  field(OUT6, "1")
  field(OUT7, "1")
  field(OUT8, "1")
  field(OUT9, "1")
  field(OUTA, "1")
  field(OUTB, "1")
  field(OUTC, "1")
  field(OUTD, "1")
  field(VME,  "1")
  field(SDIS, "EVR:LI24:PM01:EVENT4CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT4RATE") {
  field(DESC, "EVENT4 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT4CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT4EVDESC") {
  field(DESC, "EVENT4 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT4CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT4DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT4DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT4DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT5CTRL") {
  field(DESC, "EVENT5 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "144")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT5CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT5RATE") {
  field(DESC, "EVENT5 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT5CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT5EVDESC") {
  field(DESC, "EVENT5 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT5CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT5DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT5DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT5DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT6CTRL") {
  field(DESC, "EVENT6 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "145")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT6CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT6RATE") {
  field(DESC, "EVENT6 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT6CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT6EVDESC") {
  field(DESC, "EVENT6 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT6CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT6DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT6DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT6DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT7CTRL") {
  field(DESC, "EVENT7 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "146")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT7CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT7RATE") {
  field(DESC, "EVENT7 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT7CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT7EVDESC") {
  field(DESC, "EVENT7 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT7CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT7DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT7DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT7DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT8CTRL") {
  field(DESC, "EVENT8 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "140")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT8CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT8RATE") {
  field(DESC, "EVENT8 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT8CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT8EVDESC") {
  field(DESC, "EVENT8 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT8CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT8DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT8DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT8DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT9CTRL") {
  field(DESC, "EVENT9 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "10")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT9CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT9RATE") {
  field(DESC, "EVENT9 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT9CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT9EVDESC") {
  field(DESC, "EVENT9 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT9CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT9DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT9DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT9DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT10CTRL") {
  field(DESC, "EVENT10 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "11")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT10CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT10RATE") {
  field(DESC, "EVENT10 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT10CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT10EVDESC") {
  field(DESC, "EVENT10 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT10CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT10DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT10DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT10DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT11CTRL") {
  field(DESC, "EVENT11 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "12")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT11CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT11RATE") {
  field(DESC, "EVENT11 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT11CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT11EVDESC") {
  field(DESC, "EVENT11 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT11CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT11DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT11DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT11DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT12CTRL") {
  field(DESC, "EVENT12 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "13")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT12CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT12RATE") {
  field(DESC, "EVENT12 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT12CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT12EVDESC") {
  field(DESC, "EVENT12 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT12CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT12DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT12DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT12DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT13CTRL") {
  field(DESC, "EVENT13 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "14")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT13CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT13RATE") {
  field(DESC, "EVENT13 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT13CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT13EVDESC") {
  field(DESC, "EVENT13 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT13CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT13DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT13DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT13DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
record(erevent, "EVR:LI24:PM01:EVENT14CTRL") {
  field(DESC, "EVENT14 Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "15")
  field(OUT0, "0")
  field(OUT1, "0")
  field(OUT2, "0")
  field(OUT3, "0")
  field(OUT4, "0")
  field(OUT5, "0")
  field(OUT6, "0")
  field(OUT7, "0")
  field(OUT8, "0")
  field(OUT9, "0")
  field(OUTA, "0")
  field(OUTB, "0")
  field(OUTC, "0")
  field(OUTD, "0")
  field(VME,  "0")
  field(SDIS, "EVR:LI24:PM01:EVENT14CTRL.ENM")
  field(DISV, "1")
  field(DISS, "INVALID")
  info(autosaveFields, "ENM OUT0 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9 OUTA OUTB OUTC OUTD VME ENAB")
}

record(sub, "EVR:LI24:PM01:EVENT14RATE") {
  field(DESC, "EVENT14 Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(SCAN, "Event")
  field(EVNT, "121")
  field(PRIO, "MEDIUM")
  field(INPE, "EVR:LI24:PM01:EVENT14CTRL.ENM MS")
  field(EGU,  "Hz")
  field(PREC, "1")
  field(TSE, "-1")
}


record(aSub, "EVR:LI24:PM01:EVENT14EVDESC") {
  field(DESC, "EVENT14 EV Desc")
  field(PINI, "YES")
  field(SCAN, "Passive")
  field(INAM, "aSubEvDescInit")
  field(SNAM, "aSubEvDesc")
  field(INPA, "EVR:LI24:PM01:EVENT14CTRL.ENM CPP MS")
  field(FTA,  "LONG")
  field(INPB, "EVR:LI24:PM01:EVENT14DESC")
  field(FTB,  "STRING")
  field(INPC, "EVNT:SYS0:1:NAME CPP MS")
  field(FTC,  "STRING")
  field(NOC,  "256")
  field(OUTA, "EVR:LI24:PM01:EVENT14DESC PP")
  field(FTVA, "STRING")
}

record(stringin, "EVR:LI24:PM01:EVENT14DESC") {
  field(SCAN, "Passive")
  field(PINI, "YES")
  info(autosaveFields, "VAL")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERN") {
  field(DESC, "Pattern ")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "4")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERN360HZ")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERN",65,20,0,0,"IOC:LI24:PM01:PATTERN")
#! Field("IOC:LI24:PM01:PATTERN.SDIS",16777215,1,"IOC:LI24:PM01:PATTERN.SDIS")
#! Field("IOC:LI24:PM01:PATTERN.FLNK",16777215,1,"IOC:LI24:PM01:PATTERN.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERN360HZ") {
  field(DESC, "Pattern 360HZ")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "0")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERNN-1")
  field(TSE, "1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERN360HZ",65,20,0,0,"IOC:LI24:PM01:PATTERN360HZ")
#! Field("IOC:LI24:PM01:PATTERN360HZ.SDIS",16777215,1,"IOC:LI24:PM01:PATTERN360HZ.SDIS")
#! Field("IOC:LI24:PM01:PATTERN360HZ.FLNK",16777215,1,"IOC:LI24:PM01:PATTERN360HZ.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERNN-1") {
  field(DESC, "Pattern N-1")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "1")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERNN-2")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERNN-1",65,20,0,0,"IOC:LI24:PM01:PATTERNN-1")
#! Field("IOC:LI24:PM01:PATTERNN-1.SDIS",16777215,1,"IOC:LI24:PM01:PATTERNN-1.SDIS")
#! Field("IOC:LI24:PM01:PATTERNN-1.FLNK",16777215,1,"IOC:LI24:PM01:PATTERNN-1.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERNN-2") {
  field(DESC, "Pattern N-2")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "2")
  field(SDIS, "")
  field(FLNK, "")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERNN-2",65,20,0,0,"IOC:LI24:PM01:PATTERNN-2")
#! Field("IOC:LI24:PM01:PATTERNN-2.SDIS",16777215,1,"IOC:LI24:PM01:PATTERNN-2.SDIS")
#! Field("IOC:LI24:PM01:PATTERNN-2.FLNK",16777215,1,"IOC:LI24:PM01:PATTERNN-2.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERND") {
  field(DESC, "Pattern D")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "4")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERND-0")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERND",65,20,0,0,"IOC:LI24:PM01:PATTERND")
#! Field("IOC:LI24:PM01:PATTERND.SDIS",16777215,1,"IOC:LI24:PM01:PATTERND.SDIS")
#! Field("IOC:LI24:PM01:PATTERND.FLNK",16777215,1,"IOC:LI24:PM01:PATTERND.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERND-0") {
  field(DESC, "Pattern D-0")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "0")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERND-1")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERND-0",65,20,0,0,"IOC:LI24:PM01:PATTERND-0")
#! Field("IOC:LI24:PM01:PATTERND-0.SDIS",16777215,1,"IOC:LI24:PM01:PATTERND-0.SDIS")
#! Field("IOC:LI24:PM01:PATTERND-0.FLNK",16777215,1,"IOC:LI24:PM01:PATTERND-0.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERND-1") {
  field(DESC, "Pattern D-1")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "1")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERND-2")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERND-1",65,20,0,0,"IOC:LI24:PM01:PATTERND-1")
#! Field("IOC:LI24:PM01:PATTERND-1.SDIS",16777215,1,"IOC:LI24:PM01:PATTERND-1.SDIS")
#! Field("IOC:LI24:PM01:PATTERND-1.FLNK",16777215,1,"IOC:LI24:PM01:PATTERND-1.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERND-2") {
  field(DESC, "Pattern D-2")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "2")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERND-3")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERND-2",65,20,0,0,"IOC:LI24:PM01:PATTERND-2")
#! Field("IOC:LI24:PM01:PATTERND-2.SDIS",16777215,1,"IOC:LI24:PM01:PATTERND-2.SDIS")
#! Field("IOC:LI24:PM01:PATTERND-2.FLNK",16777215,1,"IOC:LI24:PM01:PATTERND-2.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERND-3") {
  field(DESC, "Pattern D-3")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(Z, "3")
  field(SDIS, "")
  field(FLNK, "IOC:LI24:PM01:PATTERNSTATE")
  field(TSE, "-1")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("IOC:LI24:PM01:PATTERND-3",65,20,0,0,"IOC:LI24:PM01:PATTERND-3")
#! Field("IOC:LI24:PM01:PATTERND-3.SDIS",16777215,1,"IOC:LI24:PM01:PATTERND-3.SDIS")
#! Field("IOC:LI24:PM01:PATTERND-3.FLNK",16777215,1,"IOC:LI24:PM01:PATTERND-3.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longSub, "IOC:LI24:PM01:FIDUCIAL") {
  field(DESC, "Fiducial Processing")
  field(INAM, "evrTimeProcInit")
  field(SNAM, "evrTimeProc")
  field(FLNK, "IOC:LI24:PM01:PATTERNFO")
  field(INPI, "0")
  field(INPJ, "4")
  field(BRSV, "INVALID")
}

record(fanout, "IOC:LI24:PM01:PATTERNFO") {
  field(LNK1, "IOC:LI24:PM01:PATTERN")
  field(LNK3, "IOC:LI24:PM01:MODIFIER5")
  field(LNK4, "")
  field(LNK5, "")
  field(LNK6, "")
}

record(longSub, "IOC:LI24:PM01:MODIFIER5") {
  field(SNAM, "evrModifier5Bits")
  field(INPV, "IOC:LI24:PM01:PATTERN.H MS")
  field(BRSV, "INVALID")
}

record(longSub, "IOC:LI24:PM01:FIDUCIALDIAG") {
  field(DESC, "FIDUCIAL Diagnostics")
  field(EVNT, "121")
  field(SCAN, "Event")
  field(PRIO, "HIGH")
  field(SNAM, "evrTimeDiag")
  field(BRSV, "INVALID")
  field(FLNK, "IOC:LI24:PM01:PATTERND")
}

record(seq, "IOC:LI24:PM01:RESETCNT") {
  field(DESC, "Counter Reset")
  field(PINI, "YES")
  field(DLY1, "1")
  field(DOL1, "1")
  field(LNK1, "IOC:LI24:PM01:FIDUCIALDIAG.R")
  field(DOL2, "1")
  field(LNK2, "IOC:LI24:PM01:PATTERNDIAG.B")
  field(LNK3, "IOC:LI24:PM01:RESETCNT.DLY1")
}

record(mbbo, "IOC:LI24:PM01:PATTERNSTATE") {
  field(DESC, "Pattern Processing State")
  field(DOL, "IOC:LI24:PM01:PATTERNDIAG PP")
  field(ZRST, "OK")
  field(ONST, "INVALID_DATA")
  field(ONSV, "INVALID")
  field(TWST, "NO_DATA")
  field(TWSV, "INVALID")
  field(THST, "INVALID_TIME")
  field(THSV, "INVALID")
  field(FRST, "MPG_IPLING")
  field(FRSV, "MAJOR")
  field(FVST, "TS_NO_SYNC")
  field(FVSV, "MAJOR")
  field(SXST, "TS_PATT_NO_SYNC")
  field(SXSV, "MAJOR")
  field(SVST, "TS_MISMATCH")
  field(SVSV, "MAJOR")
  field(EIST, "PULSEID_NO_SYNC")
  field(EISV, "MAJOR")
  field(NIST, "MODULO_NO_SYNC")
  field(NISV, "MAJOR")
  field(TEST, "TIMEOUT")
  field(TESV, "MAJOR")
  field(ELST, "ERROR")
  field(ELSV, "INVALID")
  field(UNSV, "INVALID")
  field(OMSL, "closed_loop")
  field(FLNK, "IOC:LI24:PM01:NTPSTATE")
}

record(bo, "IOC:LI24:PM01:NTPSTATE") {
  field(DESC, "NTP State")
  field(DOL, "IOC:LI24:PM01:PATTERNDIAG.R")
  field(ZNAM, "OK")
  field(ONAM, "ERROR")
  field(OSV, "INVALID")
  field(OMSL, "closed_loop")
}

record(ao, "IOC:LI24:PM01:TREF") {
  field(DESC, "IOC Trig Ref")
  field(DTYP, "Raw Soft Channel")
  field(OMSL, "supervisory")
  field(LINR, "SLOPE")
  field(EGU, "nsec")
  field(HOPR, "2.8E06")
  field(DRVH, "2.8E06")
  field(PINI, "YES")
  field(ESLO, "8.40336692324359")
  field(VAL, "1.03E06")
  field(PREC, "0")
}

#! Further lines contain data used by VisualDCT
#! View(1153,1347,0.7)
#! Record("IOC:LI24:PM01:FIDUCIAL",1360,1603,0,1,"IOC:LI24:PM01:FIDUCIAL")
#! Field("IOC:LI24:PM01:FIDUCIAL.FLNK",16777215,1,"IOC:LI24:PM01:FIDUCIAL.FLNK")
#! Link("IOC:LI24:PM01:FIDUCIAL.FLNK","IOC:LI24:PM01:PATTERNFO")
#! Field("IOC:LI24:PM01:FIDUCIAL.INPI",16777215,1,"IOC:LI24:PM01:FIDUCIAL.INPI")
#! Field("IOC:LI24:PM01:FIDUCIAL.INPJ",16777215,1,"IOC:LI24:PM01:FIDUCIAL.INPJ")
#! Record("IOC:LI24:PM01:PATTERNFO",1640,1692,0,0,"IOC:LI24:PM01:PATTERNFO")
#! Field("IOC:LI24:PM01:PATTERNFO.LNK1",16777215,1,"IOC:LI24:PM01:PATTERNFO.LNK1")
#! Field("IOC:LI24:PM01:PATTERNFO.LNK3",16777215,1,"IOC:LI24:PM01:PATTERNFO.LNK3")
#! Link("IOC:LI24:PM01:PATTERNFO.LNK3","IOC:LI24:PM01:MODIFIER5")
#! Field("IOC:LI24:PM01:PATTERNFO.LNK4",16777215,1,"IOC:LI24:PM01:PATTERNFO.LNK4")
#! Field("IOC:LI24:PM01:PATTERNFO.LNK5",16777215,1,"IOC:LI24:PM01:PATTERNFO.LNK5")
#! Field("IOC:LI24:PM01:PATTERNFO.LNK6",16777215,1,"IOC:LI24:PM01:PATTERNFO.LNK6")
#! Record("IOC:LI24:PM01:MODIFIER5",1920,1840,0,0,"IOC:LI24:PM01:MODIFIER5")
#! Field("IOC:LI24:PM01:MODIFIER5.INPV",16777215,1,"IOC:LI24:PM01:MODIFIER5.INPV")
#! Record("IOC:LI24:PM01:FIDUCIALDIAG",2400,1783,0,0,"IOC:LI24:PM01:FIDUCIALDIAG")
#! Field("IOC:LI24:PM01:FIDUCIALDIAG.FLNK",16777215,1,"IOC:LI24:PM01:FIDUCIALDIAG.FLNK")
#! Field("IOC:LI24:PM01:FIDUCIALDIAG.R",16777215,0,"IOC:LI24:PM01:FIDUCIALDIAG.R")
#! Record("IOC:LI24:PM01:RESETCNT",2080,2008,0,0,"IOC:LI24:PM01:RESETCNT")
#! Field("IOC:LI24:PM01:RESETCNT.LNK1",16777215,1,"IOC:LI24:PM01:RESETCNT.LNK1")
#! Link("IOC:LI24:PM01:RESETCNT.LNK1","IOC:LI24:PM01:FIDUCIALDIAG.R")
#! Field("IOC:LI24:PM01:RESETCNT.LNK2",16777215,1,"IOC:LI24:PM01:RESETCNT.LNK2")
#! Field("IOC:LI24:PM01:RESETCNT.DLY1",16777215,0,"IOC:LI24:PM01:RESETCNT.DLY1")
#! Field("IOC:LI24:PM01:RESETCNT.LNK3",16777215,0,"IOC:LI24:PM01:RESETCNT.LNK3")
#! Link("IOC:LI24:PM01:RESETCNT.LNK3","IOC:LI24:PM01:RESETCNT.DLY1")
#! Record("IOC:LI24:PM01:PATTERNSTATE",2400,2159,0,0,"IOC:LI24:PM01:PATTERNSTATE")
#! Field("IOC:LI24:PM01:PATTERNSTATE.DOL",16777215,1,"IOC:LI24:PM01:PATTERNSTATE.DOL")
#! Field("IOC:LI24:PM01:PATTERNSTATE.FLNK",16777215,1,"IOC:LI24:PM01:PATTERNSTATE.FLNK")
#! Link("IOC:LI24:PM01:PATTERNSTATE.FLNK","IOC:LI24:PM01:NTPSTATE")
#! Record("IOC:LI24:PM01:NTPSTATE",2660,2578,0,0,"IOC:LI24:PM01:NTPSTATE")
#! Field("IOC:LI24:PM01:NTPSTATE.DOL",16777215,1,"IOC:LI24:PM01:NTPSTATE.DOL")
#! Record("IOC:LI24:PM01:TREF",2660,2165,0,0,"IOC:LI24:PM01:TREF")
#! TextBox(TB3,2380,2120,2680,2160,0,"Dialog",12,1,16777215,"Diagnostic Records \n    Provide counters and states at a lower rate\n",null)
#! TextBox(TB2,1360,1580,1620,1620,0,"Dialog",18,1,16777215,"360 Hz Processing",null)
#! TextBox(TB1,1618,1603,1998,1683,0,"Dialog",12,1,16777215,"PATTERNFO fans out to \n1) SLC-Aware Pattern Check Records (optional)\n2) BSA EDEF Enable Records\n3) Trigger Attribute Change Records (optional)\n",null)
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../dbd/edef.dbd")
#! DBDEND


record(longSub, "IOC:LI24:PM01:PATTERNN-3") {
  field(DESC, "Pattern N-3")
  field(INAM, "evrPatternProcInit")
  field(SNAM, "evrPatternProc")
  field(BRSV, "INVALID")
# Initialize to "MPG_IPLING" (0x4000)
  field(D, "16384")
# Initialize to the invalid pulse ID (0x1FFFF)
  field(L, "131071")
  field(X, "1")
  field(Z, "3")
}

record(longSub, "IOC:LI24:PM01:PATTERNDIAG") {
  field(DESC, "Pattern Processing State")
  field(SNAM, "evrPatternState")
  field(INPA, "IOC:LI24:PM01:PATTERND-2")
  field(BRSV, "INVALID")
  field(FLNK, "IOC:LI24:PM01:FIDUCIALRATE")
}

record(sub, "IOC:LI24:PM01:FIDUCIALRATE") {
  field(DESC, "FIDUCIAL Event Rate")
  field(SNAM, "evrTimeRate")
  field(BRSV, "INVALID")
  field(INPE, "1")
  field(EGU, "Hz")
  field(PREC, "1")
  field(HIHI, "360.5")
  field(HHSV, "MAJOR")
  field(LOLO, "359.5")
  field(LLSV, "MAJOR")
  field(HOPR, "360")
}

record(erevent, "IOC:LI24:PM01:FIDUCIALCTRL") {
  field(DESC, "Fiducial Event Control")
  field(PINI, "YES")
  field(DTYP, "MRF Event Receiver")
  field(OUT, "#C0 S0 @")
  field(ENAB, "Enabled")
  field(ENM, "1")
  field(VME,  "1")
}

#! Further lines contain data used by VisualDCT
#! View(86,0,1.1)
#! Record("IOC:LI24:PM01:PATTERNN-3",202,291,0,1,"IOC:LI24:PM01:PATTERNN-3")
#! Record("IOC:LI24:PM01:PATTERNDIAG",420,294,0,0,"IOC:LI24:PM01:PATTERNDIAG")
#! Field("IOC:LI24:PM01:PATTERNDIAG.INPA",16777215,0,"IOC:LI24:PM01:PATTERNDIAG.INPA")
#! Field("IOC:LI24:PM01:PATTERNDIAG.FLNK",16777215,1,"IOC:LI24:PM01:PATTERNDIAG.FLNK")
#! Link("IOC:LI24:PM01:PATTERNDIAG.FLNK","IOC:LI24:PM01:FIDUCIALRATE")
#! Record("IOC:LI24:PM01:FIDUCIALRATE",680,350,0,0,"IOC:LI24:PM01:FIDUCIALRATE")
#! TextBox(TB0,200,40,580,260,0,"Dialog",12,1,16777215,"PATTERN\nInputs Message and parses into 5 MODIFIERS\nOutputs:\nE MODIFIER1, N-3\nF MODIFIER2, N-3\nG MODIFIER3, N-3\nH MODIFIER4, N-3\nI  MODIFIER5, N-3\nJ  BEAMCODE, N-3\nL  PULSEID, N-3",null)