record(bi, "PLC:BSY0:BC01:Bi7") {
  field(DESC, "Port BSOIC_RD bit 7")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 7, 1, 1)")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(FLNK, "BSOC:BSY0:1:RTHWEN_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWEN_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi7 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWEN PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWEN") {
  field(DESC, "BSOIC-HW_Enable")
  field(ZNAM, "Disabled")
  field(ONAM, "Enabled")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb7",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb7")
#! Field("PLC:BSY0:BC01:BSOIC_RDb7.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb7.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb7.FLNK","BSOC:BSY0:1:RTHWEN_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb7.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb7.VAL")
#! Record("BSOC:BSY0:1:RTHWEN_calc",260,18,0,1,"BSOC:BSY0:1:RTHWEN_calc")
#! Field("BSOC:BSY0:1:RTHWEN_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWEN_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWEN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb7.VAL")
#! Field("BSOC:BSY0:1:RTHWEN_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWEN_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWEN_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWEN_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWEN_calc.OUT","BSOC:BSY0:1:RTHWEN.VAL")
#! Record("BSOC:BSY0:1:RTHWEN",500,20,0,0,"BSOC:BSY0:1:RTHWEN")
#! Field("BSOC:BSY0:1:RTHWEN.VAL",16777215,1,"BSOC:BSY0:1:RTHWEN.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi6") {
  field(DESC, "Port BSOIC_RD bit 6")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 6, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(FLNK, "BSOC:BSY0:1:RTHWRESETALL_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWRESETALL_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi6 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWRESETALL PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWRESETALL") {
  field(DESC, "BSOIC-HW_Reset")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb6",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb6")
#! Field("PLC:BSY0:BC01:BSOIC_RDb6.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb6.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb6.FLNK","BSOC:BSY0:1:RTHWRESETALL_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb6.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb6.VAL")
#! Record("BSOC:BSY0:1:RTHWRESETALL_calc",260,18,0,1,"BSOC:BSY0:1:RTHWRESETALL_calc")
#! Field("BSOC:BSY0:1:RTHWRESETALL_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWRESETALL_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWRESETALL_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb6.VAL")
#! Field("BSOC:BSY0:1:RTHWRESETALL_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWRESETALL_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWRESETALL_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWRESETALL_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWRESETALL_calc.OUT","BSOC:BSY0:1:RTHWRESETALL.VAL")
#! Record("BSOC:BSY0:1:RTHWRESETALL",500,20,0,0,"BSOC:BSY0:1:RTHWRESETALL")
#! Field("BSOC:BSY0:1:RTHWRESETALL.VAL",16777215,1,"BSOC:BSY0:1:RTHWRESETALL.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi5") {
  field(DESC, "Port BSOIC_RD bit 5")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 5, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi5 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTEQP") {
  field(DESC, "BSOIC-RT_G1_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb5",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb5")
#! Field("PLC:BSY0:BC01:BSOIC_RDb5.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb5.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb5.FLNK","BSOC:BSY0:1:RTEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb5.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb5.VAL")
#! Record("BSOC:BSY0:1:RTEQP_calc",260,18,0,1,"BSOC:BSY0:1:RTEQP_calc")
#! Field("BSOC:BSY0:1:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:1:RTEQP_calc.INPA")
#! Link("BSOC:BSY0:1:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb5.VAL")
#! Field("BSOC:BSY0:1:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:1:RTEQP_calc.INPB")
#! Field("BSOC:BSY0:1:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:1:RTEQP_calc.OUT")
#! Link("BSOC:BSY0:1:RTEQP_calc.OUT","BSOC:BSY0:1:RTEQP.VAL")
#! Record("BSOC:BSY0:1:RTEQP",500,20,0,0,"BSOC:BSY0:1:RTEQP")
#! Field("BSOC:BSY0:1:RTEQP.VAL",16777215,1,"BSOC:BSY0:1:RTEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi4") {
  field(DESC, "Port BSOIC_RD bit 4")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 4, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi4 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTRAD") {
  field(DESC, "BSOIC-RT_G1_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb4",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb4")
#! Field("PLC:BSY0:BC01:BSOIC_RDb4.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb4.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb4.FLNK","BSOC:BSY0:1:RTRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb4.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb4.VAL")
#! Record("BSOC:BSY0:1:RTRAD_calc",260,18,0,1,"BSOC:BSY0:1:RTRAD_calc")
#! Field("BSOC:BSY0:1:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:1:RTRAD_calc.INPA")
#! Link("BSOC:BSY0:1:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb4.VAL")
#! Field("BSOC:BSY0:1:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:1:RTRAD_calc.INPB")
#! Field("BSOC:BSY0:1:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:1:RTRAD_calc.OUT")
#! Link("BSOC:BSY0:1:RTRAD_calc.OUT","BSOC:BSY0:1:RTRAD.VAL")
#! Record("BSOC:BSY0:1:RTRAD",500,20,0,0,"BSOC:BSY0:1:RTRAD")
#! Field("BSOC:BSY0:1:RTRAD.VAL",16777215,1,"BSOC:BSY0:1:RTRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi3") {
  field(DESC, "Port BSOIC_RD bit 3")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 3, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(FLNK, "BSOC:BSY0:1:RTHWBYP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWBYP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi3 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWBYP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWBYP") {
  field(DESC, "BSOIC-RT_G1_HW_Bypass")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb3",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb3")
#! Field("PLC:BSY0:BC01:BSOIC_RDb3.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb3.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb3.FLNK","BSOC:BSY0:1:RTHWBYP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb3.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb3.VAL")
#! Record("BSOC:BSY0:1:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:1:RTHWBYP_calc")
#! Field("BSOC:BSY0:1:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWBYP_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb3.VAL")
#! Field("BSOC:BSY0:1:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWBYP_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWBYP_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWBYP_calc.OUT","BSOC:BSY0:1:RTHWBYP.VAL")
#! Record("BSOC:BSY0:1:RTHWBYP",500,20,0,0,"BSOC:BSY0:1:RTHWBYP")
#! Field("BSOC:BSY0:1:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:1:RTHWBYP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi2") {
  field(DESC, "Port BSOIC_RD bit 2")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 2, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:3:RTEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:RTEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi2 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:RTEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:RTEQP") {
  field(DESC, "BSOIC-RT_G2_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb2",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb2")
#! Field("PLC:BSY0:BC01:BSOIC_RDb2.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb2.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb2.FLNK","BSOC:BSY0:3:RTEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb2.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb2.VAL")
#! Record("BSOC:BSY0:3:RTEQP_calc",260,18,0,1,"BSOC:BSY0:3:RTEQP_calc")
#! Field("BSOC:BSY0:3:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:3:RTEQP_calc.INPA")
#! Link("BSOC:BSY0:3:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb2.VAL")
#! Field("BSOC:BSY0:3:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:3:RTEQP_calc.INPB")
#! Field("BSOC:BSY0:3:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:3:RTEQP_calc.OUT")
#! Link("BSOC:BSY0:3:RTEQP_calc.OUT","BSOC:BSY0:3:RTEQP.VAL")
#! Record("BSOC:BSY0:3:RTEQP",500,20,0,0,"BSOC:BSY0:3:RTEQP")
#! Field("BSOC:BSY0:3:RTEQP.VAL",16777215,1,"BSOC:BSY0:3:RTEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi1") {
  field(DESC, "Port BSOIC_RD bit 1")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 1, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:3:RTRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:RTRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi1 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:RTRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:RTRAD") {
  field(DESC, "BSOIC-RT_G2_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb1",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb1")
#! Field("PLC:BSY0:BC01:BSOIC_RDb1.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb1.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb1.FLNK","BSOC:BSY0:3:RTRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb1.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb1.VAL")
#! Record("BSOC:BSY0:3:RTRAD_calc",260,18,0,1,"BSOC:BSY0:3:RTRAD_calc")
#! Field("BSOC:BSY0:3:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:3:RTRAD_calc.INPA")
#! Link("BSOC:BSY0:3:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb1.VAL")
#! Field("BSOC:BSY0:3:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:3:RTRAD_calc.INPB")
#! Field("BSOC:BSY0:3:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:3:RTRAD_calc.OUT")
#! Link("BSOC:BSY0:3:RTRAD_calc.OUT","BSOC:BSY0:3:RTRAD.VAL")
#! Record("BSOC:BSY0:3:RTRAD",500,20,0,0,"BSOC:BSY0:3:RTRAD")
#! Field("BSOC:BSY0:3:RTRAD.VAL",16777215,1,"BSOC:BSY0:3:RTRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi0") {
  field(DESC, "Port BSOIC_RD bit 0")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 0, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(FLNK, "BSOC:BSY0:3:RTHWBYP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:RTHWBYP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi0 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:RTHWBYP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:RTHWBYP") {
  field(DESC, "BSOIC-RT_G2_HW_Bypass")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb0",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb0")
#! Field("PLC:BSY0:BC01:BSOIC_RDb0.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb0.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb0.FLNK","BSOC:BSY0:3:RTHWBYP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb0.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb0.VAL")
#! Record("BSOC:BSY0:3:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:3:RTHWBYP_calc")
#! Field("BSOC:BSY0:3:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:3:RTHWBYP_calc.INPA")
#! Link("BSOC:BSY0:3:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb0.VAL")
#! Field("BSOC:BSY0:3:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:3:RTHWBYP_calc.INPB")
#! Field("BSOC:BSY0:3:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:3:RTHWBYP_calc.OUT")
#! Link("BSOC:BSY0:3:RTHWBYP_calc.OUT","BSOC:BSY0:3:RTHWBYP.VAL")
#! Record("BSOC:BSY0:3:RTHWBYP",500,20,0,0,"BSOC:BSY0:3:RTHWBYP")
#! Field("BSOC:BSY0:3:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:3:RTHWBYP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi15") {
  field(DESC, "Port BSOIC_RD bit 15")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 15, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:4:RTEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:RTEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi15 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:RTEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:RTEQP") {
  field(DESC, "BSOIC-RT_G3_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb15",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb15")
#! Field("PLC:BSY0:BC01:BSOIC_RDb15.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb15.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb15.FLNK","BSOC:BSY0:4:RTEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb15.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb15.VAL")
#! Record("BSOC:BSY0:4:RTEQP_calc",260,18,0,1,"BSOC:BSY0:4:RTEQP_calc")
#! Field("BSOC:BSY0:4:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:4:RTEQP_calc.INPA")
#! Link("BSOC:BSY0:4:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb15.VAL")
#! Field("BSOC:BSY0:4:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:4:RTEQP_calc.INPB")
#! Field("BSOC:BSY0:4:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:4:RTEQP_calc.OUT")
#! Link("BSOC:BSY0:4:RTEQP_calc.OUT","BSOC:BSY0:4:RTEQP.VAL")
#! Record("BSOC:BSY0:4:RTEQP",500,20,0,0,"BSOC:BSY0:4:RTEQP")
#! Field("BSOC:BSY0:4:RTEQP.VAL",16777215,1,"BSOC:BSY0:4:RTEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi14") {
  field(DESC, "Port BSOIC_RD bit 14")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 14, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:4:RTRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:RTRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi14 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:RTRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:RTRAD") {
  field(DESC, "BSOIC-RT_G3_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb14",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb14")
#! Field("PLC:BSY0:BC01:BSOIC_RDb14.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb14.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb14.FLNK","BSOC:BSY0:4:RTRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb14.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb14.VAL")
#! Record("BSOC:BSY0:4:RTRAD_calc",260,18,0,1,"BSOC:BSY0:4:RTRAD_calc")
#! Field("BSOC:BSY0:4:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:4:RTRAD_calc.INPA")
#! Link("BSOC:BSY0:4:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb14.VAL")
#! Field("BSOC:BSY0:4:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:4:RTRAD_calc.INPB")
#! Field("BSOC:BSY0:4:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:4:RTRAD_calc.OUT")
#! Link("BSOC:BSY0:4:RTRAD_calc.OUT","BSOC:BSY0:4:RTRAD.VAL")
#! Record("BSOC:BSY0:4:RTRAD",500,20,0,0,"BSOC:BSY0:4:RTRAD")
#! Field("BSOC:BSY0:4:RTRAD.VAL",16777215,1,"BSOC:BSY0:4:RTRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi13") {
  field(DESC, "Port BSOIC_RD bit 13")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 13, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(FLNK, "BSOC:BSY0:4:RTHWBYP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:RTHWBYP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi13 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:RTHWBYP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:RTHWBYP") {
  field(DESC, "BSOIC-RT_G3_HW_Bypass")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb13",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb13")
#! Field("PLC:BSY0:BC01:BSOIC_RDb13.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb13.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb13.FLNK","BSOC:BSY0:4:RTHWBYP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb13.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb13.VAL")
#! Record("BSOC:BSY0:4:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:4:RTHWBYP_calc")
#! Field("BSOC:BSY0:4:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:4:RTHWBYP_calc.INPA")
#! Link("BSOC:BSY0:4:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb13.VAL")
#! Field("BSOC:BSY0:4:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:4:RTHWBYP_calc.INPB")
#! Field("BSOC:BSY0:4:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:4:RTHWBYP_calc.OUT")
#! Link("BSOC:BSY0:4:RTHWBYP_calc.OUT","BSOC:BSY0:4:RTHWBYP.VAL")
#! Record("BSOC:BSY0:4:RTHWBYP",500,20,0,0,"BSOC:BSY0:4:RTHWBYP")
#! Field("BSOC:BSY0:4:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:4:RTHWBYP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi12") {
  field(DESC, "Port BSOIC_RD bit 12")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 12, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:5:RTEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:RTEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi12 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:RTEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:RTEQP") {
  field(DESC, "BSOIC-RT_G4_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb12",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb12")
#! Field("PLC:BSY0:BC01:BSOIC_RDb12.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb12.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb12.FLNK","BSOC:BSY0:5:RTEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb12.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb12.VAL")
#! Record("BSOC:BSY0:5:RTEQP_calc",260,18,0,1,"BSOC:BSY0:5:RTEQP_calc")
#! Field("BSOC:BSY0:5:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:5:RTEQP_calc.INPA")
#! Link("BSOC:BSY0:5:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb12.VAL")
#! Field("BSOC:BSY0:5:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:5:RTEQP_calc.INPB")
#! Field("BSOC:BSY0:5:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:5:RTEQP_calc.OUT")
#! Link("BSOC:BSY0:5:RTEQP_calc.OUT","BSOC:BSY0:5:RTEQP.VAL")
#! Record("BSOC:BSY0:5:RTEQP",500,20,0,0,"BSOC:BSY0:5:RTEQP")
#! Field("BSOC:BSY0:5:RTEQP.VAL",16777215,1,"BSOC:BSY0:5:RTEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi11") {
  field(DESC, "Port BSOIC_RD bit 11")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 11, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:5:RTRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:RTRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi11 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:RTRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:RTRAD") {
  field(DESC, "BSOIC-RT_G4_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb11",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb11")
#! Field("PLC:BSY0:BC01:BSOIC_RDb11.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb11.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb11.FLNK","BSOC:BSY0:5:RTRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb11.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb11.VAL")
#! Record("BSOC:BSY0:5:RTRAD_calc",260,18,0,1,"BSOC:BSY0:5:RTRAD_calc")
#! Field("BSOC:BSY0:5:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:5:RTRAD_calc.INPA")
#! Link("BSOC:BSY0:5:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb11.VAL")
#! Field("BSOC:BSY0:5:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:5:RTRAD_calc.INPB")
#! Field("BSOC:BSY0:5:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:5:RTRAD_calc.OUT")
#! Link("BSOC:BSY0:5:RTRAD_calc.OUT","BSOC:BSY0:5:RTRAD.VAL")
#! Record("BSOC:BSY0:5:RTRAD",500,20,0,0,"BSOC:BSY0:5:RTRAD")
#! Field("BSOC:BSY0:5:RTRAD.VAL",16777215,1,"BSOC:BSY0:5:RTRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi10") {
  field(DESC, "Port BSOIC_RD bit 10")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 10, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(FLNK, "BSOC:BSY0:5:RTHWBYP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:RTHWBYP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi10 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:RTHWBYP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:RTHWBYP") {
  field(DESC, "BSOIC-RT_G4_HW_Bypass")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb10",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb10")
#! Field("PLC:BSY0:BC01:BSOIC_RDb10.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb10.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb10.FLNK","BSOC:BSY0:5:RTHWBYP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb10.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb10.VAL")
#! Record("BSOC:BSY0:5:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:5:RTHWBYP_calc")
#! Field("BSOC:BSY0:5:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:5:RTHWBYP_calc.INPA")
#! Link("BSOC:BSY0:5:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb10.VAL")
#! Field("BSOC:BSY0:5:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:5:RTHWBYP_calc.INPB")
#! Field("BSOC:BSY0:5:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:5:RTHWBYP_calc.OUT")
#! Link("BSOC:BSY0:5:RTHWBYP_calc.OUT","BSOC:BSY0:5:RTHWBYP.VAL")
#! Record("BSOC:BSY0:5:RTHWBYP",500,20,0,0,"BSOC:BSY0:5:RTHWBYP")
#! Field("BSOC:BSY0:5:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:5:RTHWBYP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi9") {
  field(DESC, "Port BSOIC_RD bit 9")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 9, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:2:RTRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:2:RTRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi9 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:2:RTRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:2:RTRAD") {
  field(DESC, "BSOIC-RT_N1_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb9",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb9")
#! Field("PLC:BSY0:BC01:BSOIC_RDb9.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb9.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb9.FLNK","BSOC:BSY0:2:RTRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb9.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb9.VAL")
#! Record("BSOC:BSY0:2:RTRAD_calc",260,18,0,1,"BSOC:BSY0:2:RTRAD_calc")
#! Field("BSOC:BSY0:2:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:2:RTRAD_calc.INPA")
#! Link("BSOC:BSY0:2:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb9.VAL")
#! Field("BSOC:BSY0:2:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:2:RTRAD_calc.INPB")
#! Field("BSOC:BSY0:2:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:2:RTRAD_calc.OUT")
#! Link("BSOC:BSY0:2:RTRAD_calc.OUT","BSOC:BSY0:2:RTRAD.VAL")
#! Record("BSOC:BSY0:2:RTRAD",500,20,0,0,"BSOC:BSY0:2:RTRAD")
#! Field("BSOC:BSY0:2:RTRAD.VAL",16777215,1,"BSOC:BSY0:2:RTRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi8") {
  field(DESC, "Port BSOIC_RD bit 8")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 8, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(FLNK, "BSOC:BSY0:2:RTHWBYP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:2:RTHWBYP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi8 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:2:RTHWBYP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:2:RTHWBYP") {
  field(DESC, "BSOIC-RT_N1_HW_Bypass")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb8",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb8")
#! Field("PLC:BSY0:BC01:BSOIC_RDb8.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb8.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb8.FLNK","BSOC:BSY0:2:RTHWBYP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb8.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb8.VAL")
#! Record("BSOC:BSY0:2:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:2:RTHWBYP_calc")
#! Field("BSOC:BSY0:2:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:2:RTHWBYP_calc.INPA")
#! Link("BSOC:BSY0:2:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb8.VAL")
#! Field("BSOC:BSY0:2:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:2:RTHWBYP_calc.INPB")
#! Field("BSOC:BSY0:2:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:2:RTHWBYP_calc.OUT")
#! Link("BSOC:BSY0:2:RTHWBYP_calc.OUT","BSOC:BSY0:2:RTHWBYP.VAL")
#! Record("BSOC:BSY0:2:RTHWBYP",500,20,0,0,"BSOC:BSY0:2:RTHWBYP")
#! Field("BSOC:BSY0:2:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:2:RTHWBYP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi23") {
  field(DESC, "Port BSOIC_RD bit 23")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 23, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:6:RTRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:6:RTRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi23 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:6:RTRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:6:RTRAD") {
  field(DESC, "BSOIC-RT_N2_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb23",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb23")
#! Field("PLC:BSY0:BC01:BSOIC_RDb23.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb23.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb23.FLNK","BSOC:BSY0:6:RTRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb23.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb23.VAL")
#! Record("BSOC:BSY0:6:RTRAD_calc",260,18,0,1,"BSOC:BSY0:6:RTRAD_calc")
#! Field("BSOC:BSY0:6:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:6:RTRAD_calc.INPA")
#! Link("BSOC:BSY0:6:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb23.VAL")
#! Field("BSOC:BSY0:6:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:6:RTRAD_calc.INPB")
#! Field("BSOC:BSY0:6:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:6:RTRAD_calc.OUT")
#! Link("BSOC:BSY0:6:RTRAD_calc.OUT","BSOC:BSY0:6:RTRAD.VAL")
#! Record("BSOC:BSY0:6:RTRAD",500,20,0,0,"BSOC:BSY0:6:RTRAD")
#! Field("BSOC:BSY0:6:RTRAD.VAL",16777215,1,"BSOC:BSY0:6:RTRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi22") {
  field(DESC, "Port BSOIC_RD bit 22")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 22, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(FLNK, "BSOC:BSY0:6:RTHWBYP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:6:RTHWBYP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi22 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:6:RTHWBYP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:6:RTHWBYP") {
  field(DESC, "BSOIC-RT_N2_HW_Bypass")
  field(ZNAM, "Off")
  field(ONAM, "Bypassed")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb22",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb22")
#! Field("PLC:BSY0:BC01:BSOIC_RDb22.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb22.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb22.FLNK","BSOC:BSY0:6:RTHWBYP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb22.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb22.VAL")
#! Record("BSOC:BSY0:6:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:6:RTHWBYP_calc")
#! Field("BSOC:BSY0:6:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:6:RTHWBYP_calc.INPA")
#! Link("BSOC:BSY0:6:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb22.VAL")
#! Field("BSOC:BSY0:6:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:6:RTHWBYP_calc.INPB")
#! Field("BSOC:BSY0:6:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:6:RTHWBYP_calc.OUT")
#! Link("BSOC:BSY0:6:RTHWBYP_calc.OUT","BSOC:BSY0:6:RTHWBYP.VAL")
#! Record("BSOC:BSY0:6:RTHWBYP",500,20,0,0,"BSOC:BSY0:6:RTHWBYP")
#! Field("BSOC:BSY0:6:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:6:RTHWBYP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi21") {
  field(DESC, "Port BSOIC_RD bit 21")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 21, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTCASCI_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTCASCI_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi21 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTCASCI PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTCASCI") {
  field(DESC, "BSOIC-RT_CASCADE_Inp1")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb21",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb21")
#! Field("PLC:BSY0:BC01:BSOIC_RDb21.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb21.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb21.FLNK","BSOC:BSY0:1:RTCASCI_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb21.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb21.VAL")
#! Record("BSOC:BSY0:1:RTCASCI_calc",260,18,0,1,"BSOC:BSY0:1:RTCASCI_calc")
#! Field("BSOC:BSY0:1:RTCASCI_calc.INPA",16777215,0,"BSOC:BSY0:1:RTCASCI_calc.INPA")
#! Link("BSOC:BSY0:1:RTCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb21.VAL")
#! Field("BSOC:BSY0:1:RTCASCI_calc.INPB",16777215,1,"BSOC:BSY0:1:RTCASCI_calc.INPB")
#! Field("BSOC:BSY0:1:RTCASCI_calc.OUT",16777215,1,"BSOC:BSY0:1:RTCASCI_calc.OUT")
#! Link("BSOC:BSY0:1:RTCASCI_calc.OUT","BSOC:BSY0:1:RTCASCI.VAL")
#! Record("BSOC:BSY0:1:RTCASCI",500,20,0,0,"BSOC:BSY0:1:RTCASCI")
#! Field("BSOC:BSY0:1:RTCASCI.VAL",16777215,1,"BSOC:BSY0:1:RTCASCI.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi20") {
  field(DESC, "Port BSOIC_RD bit 20")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 20, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:2:RTCASCI_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:2:RTCASCI_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi20 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:2:RTCASCI PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:2:RTCASCI") {
  field(DESC, "BSOIC-RT_CASCADE_Inp2")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb20",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb20")
#! Field("PLC:BSY0:BC01:BSOIC_RDb20.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb20.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb20.FLNK","BSOC:BSY0:2:RTCASCI_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb20.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb20.VAL")
#! Record("BSOC:BSY0:2:RTCASCI_calc",260,18,0,1,"BSOC:BSY0:2:RTCASCI_calc")
#! Field("BSOC:BSY0:2:RTCASCI_calc.INPA",16777215,0,"BSOC:BSY0:2:RTCASCI_calc.INPA")
#! Link("BSOC:BSY0:2:RTCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb20.VAL")
#! Field("BSOC:BSY0:2:RTCASCI_calc.INPB",16777215,1,"BSOC:BSY0:2:RTCASCI_calc.INPB")
#! Field("BSOC:BSY0:2:RTCASCI_calc.OUT",16777215,1,"BSOC:BSY0:2:RTCASCI_calc.OUT")
#! Link("BSOC:BSY0:2:RTCASCI_calc.OUT","BSOC:BSY0:2:RTCASCI.VAL")
#! Record("BSOC:BSY0:2:RTCASCI",500,20,0,0,"BSOC:BSY0:2:RTCASCI")
#! Field("BSOC:BSY0:2:RTCASCI.VAL",16777215,1,"BSOC:BSY0:2:RTCASCI.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi19") {
  field(DESC, "Port BSOIC_RD bit 19")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 19, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(FLNK, "BSOC:BSY0:1:RTSORST_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTSORST_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi19 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTSORST PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTSORST") {
  field(DESC, "BSOIC-G1_Soft_Reset")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb19",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb19")
#! Field("PLC:BSY0:BC01:BSOIC_RDb19.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb19.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb19.FLNK","BSOC:BSY0:1:RTSORST_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb19.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb19.VAL")
#! Record("BSOC:BSY0:1:RTSORST_calc",260,18,0,1,"BSOC:BSY0:1:RTSORST_calc")
#! Field("BSOC:BSY0:1:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:1:RTSORST_calc.INPA")
#! Link("BSOC:BSY0:1:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb19.VAL")
#! Field("BSOC:BSY0:1:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:1:RTSORST_calc.INPB")
#! Field("BSOC:BSY0:1:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:1:RTSORST_calc.OUT")
#! Link("BSOC:BSY0:1:RTSORST_calc.OUT","BSOC:BSY0:1:RTSORST.VAL")
#! Record("BSOC:BSY0:1:RTSORST",500,20,0,0,"BSOC:BSY0:1:RTSORST")
#! Field("BSOC:BSY0:1:RTSORST.VAL",16777215,1,"BSOC:BSY0:1:RTSORST.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi18") {
  field(DESC, "Port BSOIC_RD bit 18")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 18, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(FLNK, "BSOC:BSY0:3:RTSORST_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:RTSORST_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi18 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:RTSORST PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:RTSORST") {
  field(DESC, "BSOIC-G2_Soft_Reset")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb18",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb18")
#! Field("PLC:BSY0:BC01:BSOIC_RDb18.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb18.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb18.FLNK","BSOC:BSY0:3:RTSORST_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb18.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb18.VAL")
#! Record("BSOC:BSY0:3:RTSORST_calc",260,18,0,1,"BSOC:BSY0:3:RTSORST_calc")
#! Field("BSOC:BSY0:3:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:3:RTSORST_calc.INPA")
#! Link("BSOC:BSY0:3:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb18.VAL")
#! Field("BSOC:BSY0:3:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:3:RTSORST_calc.INPB")
#! Field("BSOC:BSY0:3:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:3:RTSORST_calc.OUT")
#! Link("BSOC:BSY0:3:RTSORST_calc.OUT","BSOC:BSY0:3:RTSORST.VAL")
#! Record("BSOC:BSY0:3:RTSORST",500,20,0,0,"BSOC:BSY0:3:RTSORST")
#! Field("BSOC:BSY0:3:RTSORST.VAL",16777215,1,"BSOC:BSY0:3:RTSORST.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi17") {
  field(DESC, "Port BSOIC_RD bit 17")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 17, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(FLNK, "BSOC:BSY0:4:RTSORST_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:RTSORST_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi17 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:RTSORST PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:RTSORST") {
  field(DESC, "BSOIC-G3_Soft_Reset")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb17",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb17")
#! Field("PLC:BSY0:BC01:BSOIC_RDb17.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb17.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb17.FLNK","BSOC:BSY0:4:RTSORST_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb17.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb17.VAL")
#! Record("BSOC:BSY0:4:RTSORST_calc",260,18,0,1,"BSOC:BSY0:4:RTSORST_calc")
#! Field("BSOC:BSY0:4:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:4:RTSORST_calc.INPA")
#! Link("BSOC:BSY0:4:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb17.VAL")
#! Field("BSOC:BSY0:4:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:4:RTSORST_calc.INPB")
#! Field("BSOC:BSY0:4:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:4:RTSORST_calc.OUT")
#! Link("BSOC:BSY0:4:RTSORST_calc.OUT","BSOC:BSY0:4:RTSORST.VAL")
#! Record("BSOC:BSY0:4:RTSORST",500,20,0,0,"BSOC:BSY0:4:RTSORST")
#! Field("BSOC:BSY0:4:RTSORST.VAL",16777215,1,"BSOC:BSY0:4:RTSORST.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi16") {
  field(DESC, "Port BSOIC_RD bit 16")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 16, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(FLNK, "BSOC:BSY0:5:RTSORST_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:RTSORST_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi16 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:RTSORST PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:RTSORST") {
  field(DESC, "BSOIC-G4_Soft_Reset")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb16",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb16")
#! Field("PLC:BSY0:BC01:BSOIC_RDb16.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb16.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb16.FLNK","BSOC:BSY0:5:RTSORST_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb16.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb16.VAL")
#! Record("BSOC:BSY0:5:RTSORST_calc",260,18,0,1,"BSOC:BSY0:5:RTSORST_calc")
#! Field("BSOC:BSY0:5:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:5:RTSORST_calc.INPA")
#! Link("BSOC:BSY0:5:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb16.VAL")
#! Field("BSOC:BSY0:5:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:5:RTSORST_calc.INPB")
#! Field("BSOC:BSY0:5:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:5:RTSORST_calc.OUT")
#! Link("BSOC:BSY0:5:RTSORST_calc.OUT","BSOC:BSY0:5:RTSORST.VAL")
#! Record("BSOC:BSY0:5:RTSORST",500,20,0,0,"BSOC:BSY0:5:RTSORST")
#! Field("BSOC:BSY0:5:RTSORST.VAL",16777215,1,"BSOC:BSY0:5:RTSORST.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi95") {
  field(DESC, "Port BSOIC_RD bit 95")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 95, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "On")
  field(FLNK, "BSOC:BSY0:1:RTANNALARM_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTANNALARM_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi95 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTANNALARM PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTANNALARM") {
  field(DESC, "BSOIC-HW_Annunciator_Alarm")
  field(ZNAM, "Off")
  field(ONAM, "On")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb95",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb95")
#! Field("PLC:BSY0:BC01:BSOIC_RDb95.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb95.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb95.FLNK","BSOC:BSY0:1:RTANNALARM_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb95.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb95.VAL")
#! Record("BSOC:BSY0:1:RTANNALARM_calc",260,18,0,1,"BSOC:BSY0:1:RTANNALARM_calc")
#! Field("BSOC:BSY0:1:RTANNALARM_calc.INPA",16777215,0,"BSOC:BSY0:1:RTANNALARM_calc.INPA")
#! Link("BSOC:BSY0:1:RTANNALARM_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb95.VAL")
#! Field("BSOC:BSY0:1:RTANNALARM_calc.INPB",16777215,1,"BSOC:BSY0:1:RTANNALARM_calc.INPB")
#! Field("BSOC:BSY0:1:RTANNALARM_calc.OUT",16777215,1,"BSOC:BSY0:1:RTANNALARM_calc.OUT")
#! Link("BSOC:BSY0:1:RTANNALARM_calc.OUT","BSOC:BSY0:1:RTANNALARM.VAL")
#! Record("BSOC:BSY0:1:RTANNALARM",500,20,0,0,"BSOC:BSY0:1:RTANNALARM")
#! Field("BSOC:BSY0:1:RTANNALARM.VAL",16777215,1,"BSOC:BSY0:1:RTANNALARM.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi94") {
  field(DESC, "Port BSOIC_RD bit 94")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 94, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "On")
  field(FLNK, "BSOC:BSY0:1:RTCASCO_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTCASCO_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi94 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTCASCO PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTCASCO") {
  field(DESC, "BSOIC-HW_Cascade_Out")
  field(ZNAM, "Off")
  field(ONAM, "On")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb94",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb94")
#! Field("PLC:BSY0:BC01:BSOIC_RDb94.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb94.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb94.FLNK","BSOC:BSY0:1:RTCASCO_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb94.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb94.VAL")
#! Record("BSOC:BSY0:1:RTCASCO_calc",260,18,0,1,"BSOC:BSY0:1:RTCASCO_calc")
#! Field("BSOC:BSY0:1:RTCASCO_calc.INPA",16777215,0,"BSOC:BSY0:1:RTCASCO_calc.INPA")
#! Link("BSOC:BSY0:1:RTCASCO_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb94.VAL")
#! Field("BSOC:BSY0:1:RTCASCO_calc.INPB",16777215,1,"BSOC:BSY0:1:RTCASCO_calc.INPB")
#! Field("BSOC:BSY0:1:RTCASCO_calc.OUT",16777215,1,"BSOC:BSY0:1:RTCASCO_calc.OUT")
#! Link("BSOC:BSY0:1:RTCASCO_calc.OUT","BSOC:BSY0:1:RTCASCO.VAL")
#! Record("BSOC:BSY0:1:RTCASCO",500,20,0,0,"BSOC:BSY0:1:RTCASCO")
#! Field("BSOC:BSY0:1:RTCASCO.VAL",16777215,1,"BSOC:BSY0:1:RTCASCO.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi93") {
  field(DESC, "Port BSOIC_RD bit 93")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 93, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTHWSO1_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWSO1_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi93 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWSO1 PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWSO1") {
  field(DESC, "BSOIC-HW_Safety_Out1")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb93",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb93")
#! Field("PLC:BSY0:BC01:BSOIC_RDb93.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb93.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb93.FLNK","BSOC:BSY0:1:RTHWSO1_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb93.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb93.VAL")
#! Record("BSOC:BSY0:1:RTHWSO1_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO1_calc")
#! Field("BSOC:BSY0:1:RTHWSO1_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO1_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWSO1_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb93.VAL")
#! Field("BSOC:BSY0:1:RTHWSO1_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO1_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWSO1_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO1_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWSO1_calc.OUT","BSOC:BSY0:1:RTHWSO1.VAL")
#! Record("BSOC:BSY0:1:RTHWSO1",500,20,0,0,"BSOC:BSY0:1:RTHWSO1")
#! Field("BSOC:BSY0:1:RTHWSO1.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO1.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi92") {
  field(DESC, "Port BSOIC_RD bit 92")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 92, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTHWSO2_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWSO2_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi92 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWSO2 PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWSO2") {
  field(DESC, "BSOIC-HW_Safety_Out2")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb92",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb92")
#! Field("PLC:BSY0:BC01:BSOIC_RDb92.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb92.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb92.FLNK","BSOC:BSY0:1:RTHWSO2_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb92.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb92.VAL")
#! Record("BSOC:BSY0:1:RTHWSO2_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO2_calc")
#! Field("BSOC:BSY0:1:RTHWSO2_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO2_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWSO2_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb92.VAL")
#! Field("BSOC:BSY0:1:RTHWSO2_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO2_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWSO2_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO2_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWSO2_calc.OUT","BSOC:BSY0:1:RTHWSO2.VAL")
#! Record("BSOC:BSY0:1:RTHWSO2",500,20,0,0,"BSOC:BSY0:1:RTHWSO2")
#! Field("BSOC:BSY0:1:RTHWSO2.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO2.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi91") {
  field(DESC, "Port BSOIC_RD bit 91")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 91, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTHWSO3_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWSO3_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi91 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWSO3 PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWSO3") {
  field(DESC, "BSOIC-HW_Safety_Out3")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb91",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb91")
#! Field("PLC:BSY0:BC01:BSOIC_RDb91.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb91.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb91.FLNK","BSOC:BSY0:1:RTHWSO3_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb91.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb91.VAL")
#! Record("BSOC:BSY0:1:RTHWSO3_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO3_calc")
#! Field("BSOC:BSY0:1:RTHWSO3_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO3_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWSO3_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb91.VAL")
#! Field("BSOC:BSY0:1:RTHWSO3_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO3_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWSO3_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO3_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWSO3_calc.OUT","BSOC:BSY0:1:RTHWSO3.VAL")
#! Record("BSOC:BSY0:1:RTHWSO3",500,20,0,0,"BSOC:BSY0:1:RTHWSO3")
#! Field("BSOC:BSY0:1:RTHWSO3.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO3.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi90") {
  field(DESC, "Port BSOIC_RD bit 90")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 90, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:RTHWSO4_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:RTHWSO4_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi90 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:RTHWSO4 PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:RTHWSO4") {
  field(DESC, "BSOIC-HW_Safety_Out4")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb90",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb90")
#! Field("PLC:BSY0:BC01:BSOIC_RDb90.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb90.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb90.FLNK","BSOC:BSY0:1:RTHWSO4_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb90.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb90.VAL")
#! Record("BSOC:BSY0:1:RTHWSO4_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO4_calc")
#! Field("BSOC:BSY0:1:RTHWSO4_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO4_calc.INPA")
#! Link("BSOC:BSY0:1:RTHWSO4_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb90.VAL")
#! Field("BSOC:BSY0:1:RTHWSO4_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO4_calc.INPB")
#! Field("BSOC:BSY0:1:RTHWSO4_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO4_calc.OUT")
#! Link("BSOC:BSY0:1:RTHWSO4_calc.OUT","BSOC:BSY0:1:RTHWSO4.VAL")
#! Record("BSOC:BSY0:1:RTHWSO4",500,20,0,0,"BSOC:BSY0:1:RTHWSO4")
#! Field("BSOC:BSY0:1:RTHWSO4.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO4.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi89") {
  field(DESC, "Port BSOIC_RD bit 89")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 89, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:LATEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:LATEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi89 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:LATEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:LATEQP") {
  field(DESC, "BSOIC-LAT_G1_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb89",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb89")
#! Field("PLC:BSY0:BC01:BSOIC_RDb89.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb89.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb89.FLNK","BSOC:BSY0:1:LATEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb89.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb89.VAL")
#! Record("BSOC:BSY0:1:LATEQP_calc",260,18,0,1,"BSOC:BSY0:1:LATEQP_calc")
#! Field("BSOC:BSY0:1:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:1:LATEQP_calc.INPA")
#! Link("BSOC:BSY0:1:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb89.VAL")
#! Field("BSOC:BSY0:1:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:1:LATEQP_calc.INPB")
#! Field("BSOC:BSY0:1:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:1:LATEQP_calc.OUT")
#! Link("BSOC:BSY0:1:LATEQP_calc.OUT","BSOC:BSY0:1:LATEQP.VAL")
#! Record("BSOC:BSY0:1:LATEQP",500,20,0,0,"BSOC:BSY0:1:LATEQP")
#! Field("BSOC:BSY0:1:LATEQP.VAL",16777215,1,"BSOC:BSY0:1:LATEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi88") {
  field(DESC, "Port BSOIC_RD bit 88")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 88, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:LATRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:LATRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi88 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:LATRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:LATRAD") {
  field(DESC, "BSOIC-LAT_G1_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb88",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb88")
#! Field("PLC:BSY0:BC01:BSOIC_RDb88.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb88.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb88.FLNK","BSOC:BSY0:1:LATRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb88.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb88.VAL")
#! Record("BSOC:BSY0:1:LATRAD_calc",260,18,0,1,"BSOC:BSY0:1:LATRAD_calc")
#! Field("BSOC:BSY0:1:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:1:LATRAD_calc.INPA")
#! Link("BSOC:BSY0:1:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb88.VAL")
#! Field("BSOC:BSY0:1:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:1:LATRAD_calc.INPB")
#! Field("BSOC:BSY0:1:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:1:LATRAD_calc.OUT")
#! Link("BSOC:BSY0:1:LATRAD_calc.OUT","BSOC:BSY0:1:LATRAD.VAL")
#! Record("BSOC:BSY0:1:LATRAD",500,20,0,0,"BSOC:BSY0:1:LATRAD")
#! Field("BSOC:BSY0:1:LATRAD.VAL",16777215,1,"BSOC:BSY0:1:LATRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi103") {
  field(DESC, "Port BSOIC_RD bit 103")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 103, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:3:LATEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:LATEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi103 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:LATEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:LATEQP") {
  field(DESC, "BSOIC-LAT_G2_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb103",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb103")
#! Field("PLC:BSY0:BC01:BSOIC_RDb103.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb103.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb103.FLNK","BSOC:BSY0:3:LATEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb103.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb103.VAL")
#! Record("BSOC:BSY0:3:LATEQP_calc",260,18,0,1,"BSOC:BSY0:3:LATEQP_calc")
#! Field("BSOC:BSY0:3:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:3:LATEQP_calc.INPA")
#! Link("BSOC:BSY0:3:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb103.VAL")
#! Field("BSOC:BSY0:3:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:3:LATEQP_calc.INPB")
#! Field("BSOC:BSY0:3:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:3:LATEQP_calc.OUT")
#! Link("BSOC:BSY0:3:LATEQP_calc.OUT","BSOC:BSY0:3:LATEQP.VAL")
#! Record("BSOC:BSY0:3:LATEQP",500,20,0,0,"BSOC:BSY0:3:LATEQP")
#! Field("BSOC:BSY0:3:LATEQP.VAL",16777215,1,"BSOC:BSY0:3:LATEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi102") {
  field(DESC, "Port BSOIC_RD bit 102")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 102, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:3:LATRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:LATRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi102 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:LATRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:LATRAD") {
  field(DESC, "BSOIC-LAT_G2_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb102",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb102")
#! Field("PLC:BSY0:BC01:BSOIC_RDb102.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb102.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb102.FLNK","BSOC:BSY0:3:LATRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb102.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb102.VAL")
#! Record("BSOC:BSY0:3:LATRAD_calc",260,18,0,1,"BSOC:BSY0:3:LATRAD_calc")
#! Field("BSOC:BSY0:3:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:3:LATRAD_calc.INPA")
#! Link("BSOC:BSY0:3:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb102.VAL")
#! Field("BSOC:BSY0:3:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:3:LATRAD_calc.INPB")
#! Field("BSOC:BSY0:3:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:3:LATRAD_calc.OUT")
#! Link("BSOC:BSY0:3:LATRAD_calc.OUT","BSOC:BSY0:3:LATRAD.VAL")
#! Record("BSOC:BSY0:3:LATRAD",500,20,0,0,"BSOC:BSY0:3:LATRAD")
#! Field("BSOC:BSY0:3:LATRAD.VAL",16777215,1,"BSOC:BSY0:3:LATRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi101") {
  field(DESC, "Port BSOIC_RD bit 101")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 101, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:4:LATEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:LATEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi101 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:LATEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:LATEQP") {
  field(DESC, "BSOIC-LAT_G3_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb101",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb101")
#! Field("PLC:BSY0:BC01:BSOIC_RDb101.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb101.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb101.FLNK","BSOC:BSY0:4:LATEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb101.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb101.VAL")
#! Record("BSOC:BSY0:4:LATEQP_calc",260,18,0,1,"BSOC:BSY0:4:LATEQP_calc")
#! Field("BSOC:BSY0:4:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:4:LATEQP_calc.INPA")
#! Link("BSOC:BSY0:4:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb101.VAL")
#! Field("BSOC:BSY0:4:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:4:LATEQP_calc.INPB")
#! Field("BSOC:BSY0:4:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:4:LATEQP_calc.OUT")
#! Link("BSOC:BSY0:4:LATEQP_calc.OUT","BSOC:BSY0:4:LATEQP.VAL")
#! Record("BSOC:BSY0:4:LATEQP",500,20,0,0,"BSOC:BSY0:4:LATEQP")
#! Field("BSOC:BSY0:4:LATEQP.VAL",16777215,1,"BSOC:BSY0:4:LATEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi100") {
  field(DESC, "Port BSOIC_RD bit 100")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 100, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:4:LATRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:LATRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi100 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:LATRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:LATRAD") {
  field(DESC, "BSOIC-LAT_G3_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb100",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb100")
#! Field("PLC:BSY0:BC01:BSOIC_RDb100.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb100.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb100.FLNK","BSOC:BSY0:4:LATRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb100.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb100.VAL")
#! Record("BSOC:BSY0:4:LATRAD_calc",260,18,0,1,"BSOC:BSY0:4:LATRAD_calc")
#! Field("BSOC:BSY0:4:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:4:LATRAD_calc.INPA")
#! Link("BSOC:BSY0:4:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb100.VAL")
#! Field("BSOC:BSY0:4:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:4:LATRAD_calc.INPB")
#! Field("BSOC:BSY0:4:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:4:LATRAD_calc.OUT")
#! Link("BSOC:BSY0:4:LATRAD_calc.OUT","BSOC:BSY0:4:LATRAD.VAL")
#! Record("BSOC:BSY0:4:LATRAD",500,20,0,0,"BSOC:BSY0:4:LATRAD")
#! Field("BSOC:BSY0:4:LATRAD.VAL",16777215,1,"BSOC:BSY0:4:LATRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi99") {
  field(DESC, "Port BSOIC_RD bit 99")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 99, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:5:LATEQP_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:LATEQP_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi99 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:LATEQP PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:LATEQP") {
  field(DESC, "BSOIC-LAT_G4_Equip_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb99",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb99")
#! Field("PLC:BSY0:BC01:BSOIC_RDb99.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb99.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb99.FLNK","BSOC:BSY0:5:LATEQP_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb99.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb99.VAL")
#! Record("BSOC:BSY0:5:LATEQP_calc",260,18,0,1,"BSOC:BSY0:5:LATEQP_calc")
#! Field("BSOC:BSY0:5:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:5:LATEQP_calc.INPA")
#! Link("BSOC:BSY0:5:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb99.VAL")
#! Field("BSOC:BSY0:5:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:5:LATEQP_calc.INPB")
#! Field("BSOC:BSY0:5:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:5:LATEQP_calc.OUT")
#! Link("BSOC:BSY0:5:LATEQP_calc.OUT","BSOC:BSY0:5:LATEQP.VAL")
#! Record("BSOC:BSY0:5:LATEQP",500,20,0,0,"BSOC:BSY0:5:LATEQP")
#! Field("BSOC:BSY0:5:LATEQP.VAL",16777215,1,"BSOC:BSY0:5:LATEQP.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi98") {
  field(DESC, "Port BSOIC_RD bit 98")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 98, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:5:LATRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:LATRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi98 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:LATRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:LATRAD") {
  field(DESC, "BSOIC-LAT_G4_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb98",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb98")
#! Field("PLC:BSY0:BC01:BSOIC_RDb98.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb98.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb98.FLNK","BSOC:BSY0:5:LATRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb98.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb98.VAL")
#! Record("BSOC:BSY0:5:LATRAD_calc",260,18,0,1,"BSOC:BSY0:5:LATRAD_calc")
#! Field("BSOC:BSY0:5:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:5:LATRAD_calc.INPA")
#! Link("BSOC:BSY0:5:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb98.VAL")
#! Field("BSOC:BSY0:5:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:5:LATRAD_calc.INPB")
#! Field("BSOC:BSY0:5:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:5:LATRAD_calc.OUT")
#! Link("BSOC:BSY0:5:LATRAD_calc.OUT","BSOC:BSY0:5:LATRAD.VAL")
#! Record("BSOC:BSY0:5:LATRAD",500,20,0,0,"BSOC:BSY0:5:LATRAD")
#! Field("BSOC:BSY0:5:LATRAD.VAL",16777215,1,"BSOC:BSY0:5:LATRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi97") {
  field(DESC, "Port BSOIC_RD bit 97")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 97, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:2:LATRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:2:LATRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi97 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:2:LATRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:2:LATRAD") {
  field(DESC, "BSOIC-LAT_N1_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb97",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb97")
#! Field("PLC:BSY0:BC01:BSOIC_RDb97.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb97.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb97.FLNK","BSOC:BSY0:2:LATRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb97.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb97.VAL")
#! Record("BSOC:BSY0:2:LATRAD_calc",260,18,0,1,"BSOC:BSY0:2:LATRAD_calc")
#! Field("BSOC:BSY0:2:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:2:LATRAD_calc.INPA")
#! Link("BSOC:BSY0:2:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb97.VAL")
#! Field("BSOC:BSY0:2:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:2:LATRAD_calc.INPB")
#! Field("BSOC:BSY0:2:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:2:LATRAD_calc.OUT")
#! Link("BSOC:BSY0:2:LATRAD_calc.OUT","BSOC:BSY0:2:LATRAD.VAL")
#! Record("BSOC:BSY0:2:LATRAD",500,20,0,0,"BSOC:BSY0:2:LATRAD")
#! Field("BSOC:BSY0:2:LATRAD.VAL",16777215,1,"BSOC:BSY0:2:LATRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi96") {
  field(DESC, "Port BSOIC_RD bit 96")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 96, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:6:LATRAD_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:6:LATRAD_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi96 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:6:LATRAD PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:6:LATRAD") {
  field(DESC, "BSOIC-LAT_N2_RAD_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb96",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb96")
#! Field("PLC:BSY0:BC01:BSOIC_RDb96.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb96.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb96.FLNK","BSOC:BSY0:6:LATRAD_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb96.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb96.VAL")
#! Record("BSOC:BSY0:6:LATRAD_calc",260,18,0,1,"BSOC:BSY0:6:LATRAD_calc")
#! Field("BSOC:BSY0:6:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:6:LATRAD_calc.INPA")
#! Link("BSOC:BSY0:6:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb96.VAL")
#! Field("BSOC:BSY0:6:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:6:LATRAD_calc.INPB")
#! Field("BSOC:BSY0:6:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:6:LATRAD_calc.OUT")
#! Link("BSOC:BSY0:6:LATRAD_calc.OUT","BSOC:BSY0:6:LATRAD.VAL")
#! Record("BSOC:BSY0:6:LATRAD",500,20,0,0,"BSOC:BSY0:6:LATRAD")
#! Field("BSOC:BSY0:6:LATRAD.VAL",16777215,1,"BSOC:BSY0:6:LATRAD.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi111") {
  field(DESC, "Port BSOIC_RD bit 111")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 111, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:LATCASCI_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:LATCASCI_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi111 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:LATCASCI PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:LATCASCI") {
  field(DESC, "BSOIC-LAT_CASCADE_Inp1")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb111",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb111")
#! Field("PLC:BSY0:BC01:BSOIC_RDb111.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb111.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb111.FLNK","BSOC:BSY0:1:LATCASCI_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb111.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb111.VAL")
#! Record("BSOC:BSY0:1:LATCASCI_calc",260,18,0,1,"BSOC:BSY0:1:LATCASCI_calc")
#! Field("BSOC:BSY0:1:LATCASCI_calc.INPA",16777215,0,"BSOC:BSY0:1:LATCASCI_calc.INPA")
#! Link("BSOC:BSY0:1:LATCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb111.VAL")
#! Field("BSOC:BSY0:1:LATCASCI_calc.INPB",16777215,1,"BSOC:BSY0:1:LATCASCI_calc.INPB")
#! Field("BSOC:BSY0:1:LATCASCI_calc.OUT",16777215,1,"BSOC:BSY0:1:LATCASCI_calc.OUT")
#! Link("BSOC:BSY0:1:LATCASCI_calc.OUT","BSOC:BSY0:1:LATCASCI.VAL")
#! Record("BSOC:BSY0:1:LATCASCI",500,20,0,0,"BSOC:BSY0:1:LATCASCI")
#! Field("BSOC:BSY0:1:LATCASCI.VAL",16777215,1,"BSOC:BSY0:1:LATCASCI.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi110") {
  field(DESC, "Port BSOIC_RD bit 110")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 110, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:2:LATCASCI_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:2:LATCASCI_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi110 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:2:LATCASCI PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:2:LATCASCI") {
  field(DESC, "BSOIC-LAT_CASCADE_Inp2")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb110",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb110")
#! Field("PLC:BSY0:BC01:BSOIC_RDb110.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb110.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb110.FLNK","BSOC:BSY0:2:LATCASCI_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb110.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb110.VAL")
#! Record("BSOC:BSY0:2:LATCASCI_calc",260,18,0,1,"BSOC:BSY0:2:LATCASCI_calc")
#! Field("BSOC:BSY0:2:LATCASCI_calc.INPA",16777215,0,"BSOC:BSY0:2:LATCASCI_calc.INPA")
#! Link("BSOC:BSY0:2:LATCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb110.VAL")
#! Field("BSOC:BSY0:2:LATCASCI_calc.INPB",16777215,1,"BSOC:BSY0:2:LATCASCI_calc.INPB")
#! Field("BSOC:BSY0:2:LATCASCI_calc.OUT",16777215,1,"BSOC:BSY0:2:LATCASCI_calc.OUT")
#! Link("BSOC:BSY0:2:LATCASCI_calc.OUT","BSOC:BSY0:2:LATCASCI.VAL")
#! Record("BSOC:BSY0:2:LATCASCI",500,20,0,0,"BSOC:BSY0:2:LATCASCI")
#! Field("BSOC:BSY0:2:LATCASCI.VAL",16777215,1,"BSOC:BSY0:2:LATCASCI.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi109") {
  field(DESC, "Port BSOIC_RD bit 109")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 109, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:ALLGOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:ALLGOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi109 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:ALLGOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:ALLGOK") {
  field(DESC, "BSOIC-All_Gamma_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb109",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb109")
#! Field("PLC:BSY0:BC01:BSOIC_RDb109.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb109.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb109.FLNK","BSOC:BSY0:1:ALLGOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb109.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb109.VAL")
#! Record("BSOC:BSY0:1:ALLGOK_calc",260,18,0,1,"BSOC:BSY0:1:ALLGOK_calc")
#! Field("BSOC:BSY0:1:ALLGOK_calc.INPA",16777215,0,"BSOC:BSY0:1:ALLGOK_calc.INPA")
#! Link("BSOC:BSY0:1:ALLGOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb109.VAL")
#! Field("BSOC:BSY0:1:ALLGOK_calc.INPB",16777215,1,"BSOC:BSY0:1:ALLGOK_calc.INPB")
#! Field("BSOC:BSY0:1:ALLGOK_calc.OUT",16777215,1,"BSOC:BSY0:1:ALLGOK_calc.OUT")
#! Link("BSOC:BSY0:1:ALLGOK_calc.OUT","BSOC:BSY0:1:ALLGOK.VAL")
#! Record("BSOC:BSY0:1:ALLGOK",500,20,0,0,"BSOC:BSY0:1:ALLGOK")
#! Field("BSOC:BSY0:1:ALLGOK.VAL",16777215,1,"BSOC:BSY0:1:ALLGOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi108") {
  field(DESC, "Port BSOIC_RD bit 108")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 108, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:ALLNOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:ALLNOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi108 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:ALLNOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:ALLNOK") {
  field(DESC, "BSOIC-All_Neutron_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb108",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb108")
#! Field("PLC:BSY0:BC01:BSOIC_RDb108.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb108.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb108.FLNK","BSOC:BSY0:1:ALLNOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb108.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb108.VAL")
#! Record("BSOC:BSY0:1:ALLNOK_calc",260,18,0,1,"BSOC:BSY0:1:ALLNOK_calc")
#! Field("BSOC:BSY0:1:ALLNOK_calc.INPA",16777215,0,"BSOC:BSY0:1:ALLNOK_calc.INPA")
#! Link("BSOC:BSY0:1:ALLNOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb108.VAL")
#! Field("BSOC:BSY0:1:ALLNOK_calc.INPB",16777215,1,"BSOC:BSY0:1:ALLNOK_calc.INPB")
#! Field("BSOC:BSY0:1:ALLNOK_calc.OUT",16777215,1,"BSOC:BSY0:1:ALLNOK_calc.OUT")
#! Link("BSOC:BSY0:1:ALLNOK_calc.OUT","BSOC:BSY0:1:ALLNOK.VAL")
#! Record("BSOC:BSY0:1:ALLNOK",500,20,0,0,"BSOC:BSY0:1:ALLNOK")
#! Field("BSOC:BSY0:1:ALLNOK.VAL",16777215,1,"BSOC:BSY0:1:ALLNOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi107") {
  field(DESC, "Port BSOIC_RD bit 107")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 107, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:ALLOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:ALLOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi107 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:ALLOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:ALLOK") {
  field(DESC, "BSOIC-All_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb107",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb107")
#! Field("PLC:BSY0:BC01:BSOIC_RDb107.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb107.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb107.FLNK","BSOC:BSY0:1:ALLOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb107.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb107.VAL")
#! Record("BSOC:BSY0:1:ALLOK_calc",260,18,0,1,"BSOC:BSY0:1:ALLOK_calc")
#! Field("BSOC:BSY0:1:ALLOK_calc.INPA",16777215,0,"BSOC:BSY0:1:ALLOK_calc.INPA")
#! Link("BSOC:BSY0:1:ALLOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb107.VAL")
#! Field("BSOC:BSY0:1:ALLOK_calc.INPB",16777215,1,"BSOC:BSY0:1:ALLOK_calc.INPB")
#! Field("BSOC:BSY0:1:ALLOK_calc.OUT",16777215,1,"BSOC:BSY0:1:ALLOK_calc.OUT")
#! Link("BSOC:BSY0:1:ALLOK_calc.OUT","BSOC:BSY0:1:ALLOK.VAL")
#! Record("BSOC:BSY0:1:ALLOK",500,20,0,0,"BSOC:BSY0:1:ALLOK")
#! Field("BSOC:BSY0:1:ALLOK.VAL",16777215,1,"BSOC:BSY0:1:ALLOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi106") {
  field(DESC, "Port BSOIC_RD bit 106")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 106, 1, 1)")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(FLNK, "BSOC:BSY0:1:EQPWARN_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:EQPWARN_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi106 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:EQPWARN PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:EQPWARN") {
  field(DESC, "BSOIC-Equip_Warn_G1")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb106",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb106")
#! Field("PLC:BSY0:BC01:BSOIC_RDb106.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb106.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb106.FLNK","BSOC:BSY0:1:EQPWARN_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb106.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb106.VAL")
#! Record("BSOC:BSY0:1:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:1:EQPWARN_calc")
#! Field("BSOC:BSY0:1:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:1:EQPWARN_calc.INPA")
#! Link("BSOC:BSY0:1:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb106.VAL")
#! Field("BSOC:BSY0:1:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:1:EQPWARN_calc.INPB")
#! Field("BSOC:BSY0:1:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:1:EQPWARN_calc.OUT")
#! Link("BSOC:BSY0:1:EQPWARN_calc.OUT","BSOC:BSY0:1:EQPWARN.VAL")
#! Record("BSOC:BSY0:1:EQPWARN",500,20,0,0,"BSOC:BSY0:1:EQPWARN")
#! Field("BSOC:BSY0:1:EQPWARN.VAL",16777215,1,"BSOC:BSY0:1:EQPWARN.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi105") {
  field(DESC, "Port BSOIC_RD bit 105")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 105, 1, 1)")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(FLNK, "BSOC:BSY0:3:EQPWARN_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:EQPWARN_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi105 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:EQPWARN PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:EQPWARN") {
  field(DESC, "BSOIC-Equip_Warn_G2")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb105",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb105")
#! Field("PLC:BSY0:BC01:BSOIC_RDb105.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb105.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb105.FLNK","BSOC:BSY0:3:EQPWARN_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb105.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb105.VAL")
#! Record("BSOC:BSY0:3:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:3:EQPWARN_calc")
#! Field("BSOC:BSY0:3:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:3:EQPWARN_calc.INPA")
#! Link("BSOC:BSY0:3:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb105.VAL")
#! Field("BSOC:BSY0:3:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:3:EQPWARN_calc.INPB")
#! Field("BSOC:BSY0:3:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:3:EQPWARN_calc.OUT")
#! Link("BSOC:BSY0:3:EQPWARN_calc.OUT","BSOC:BSY0:3:EQPWARN.VAL")
#! Record("BSOC:BSY0:3:EQPWARN",500,20,0,0,"BSOC:BSY0:3:EQPWARN")
#! Field("BSOC:BSY0:3:EQPWARN.VAL",16777215,1,"BSOC:BSY0:3:EQPWARN.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi104") {
  field(DESC, "Port BSOIC_RD bit 104")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 104, 1, 1)")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(FLNK, "BSOC:BSY0:4:EQPWARN_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:EQPWARN_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi104 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:EQPWARN PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:EQPWARN") {
  field(DESC, "BSOIC-Equip_Warn_G3")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb104",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb104")
#! Field("PLC:BSY0:BC01:BSOIC_RDb104.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb104.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb104.FLNK","BSOC:BSY0:4:EQPWARN_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb104.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb104.VAL")
#! Record("BSOC:BSY0:4:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:4:EQPWARN_calc")
#! Field("BSOC:BSY0:4:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:4:EQPWARN_calc.INPA")
#! Link("BSOC:BSY0:4:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb104.VAL")
#! Field("BSOC:BSY0:4:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:4:EQPWARN_calc.INPB")
#! Field("BSOC:BSY0:4:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:4:EQPWARN_calc.OUT")
#! Link("BSOC:BSY0:4:EQPWARN_calc.OUT","BSOC:BSY0:4:EQPWARN.VAL")
#! Record("BSOC:BSY0:4:EQPWARN",500,20,0,0,"BSOC:BSY0:4:EQPWARN")
#! Field("BSOC:BSY0:4:EQPWARN.VAL",16777215,1,"BSOC:BSY0:4:EQPWARN.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi119") {
  field(DESC, "Port BSOIC_RD bit 119")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 119, 1, 1)")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(FLNK, "BSOC:BSY0:5:EQPWARN_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:EQPWARN_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi119 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:EQPWARN PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:EQPWARN") {
  field(DESC, "BSOIC-Equip_Warn_G4")
  field(ZNAM, "Ok")
  field(ONAM, "Fault")
  field(ZSV, "NO_ALARM")
  field(OSV, "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb119",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb119")
#! Field("PLC:BSY0:BC01:BSOIC_RDb119.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb119.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb119.FLNK","BSOC:BSY0:5:EQPWARN_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb119.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb119.VAL")
#! Record("BSOC:BSY0:5:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:5:EQPWARN_calc")
#! Field("BSOC:BSY0:5:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:5:EQPWARN_calc.INPA")
#! Link("BSOC:BSY0:5:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb119.VAL")
#! Field("BSOC:BSY0:5:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:5:EQPWARN_calc.INPB")
#! Field("BSOC:BSY0:5:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:5:EQPWARN_calc.OUT")
#! Link("BSOC:BSY0:5:EQPWARN_calc.OUT","BSOC:BSY0:5:EQPWARN.VAL")
#! Record("BSOC:BSY0:5:EQPWARN",500,20,0,0,"BSOC:BSY0:5:EQPWARN")
#! Field("BSOC:BSY0:5:EQPWARN.VAL",16777215,1,"BSOC:BSY0:5:EQPWARN.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi117") {
  field(DESC, "Port BSOIC_RD bit 117")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 117, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "On")
  field(FLNK, "BSOC:BSY0:1:PLCHB_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:PLCHB_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi117 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:PLCHB PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:PLCHB") {
  field(DESC, "BSOIC-PLC_Heartbeat")
  field(ZNAM, "Off")
  field(ONAM, "On")
  field(ZSV, "NO_ALARM")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb117",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb117")
#! Field("PLC:BSY0:BC01:BSOIC_RDb117.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb117.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb117.FLNK","BSOC:BSY0:1:PLCHB_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb117.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb117.VAL")
#! Record("BSOC:BSY0:1:PLCHB_calc",260,18,0,1,"BSOC:BSY0:1:PLCHB_calc")
#! Field("BSOC:BSY0:1:PLCHB_calc.INPA",16777215,0,"BSOC:BSY0:1:PLCHB_calc.INPA")
#! Link("BSOC:BSY0:1:PLCHB_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb117.VAL")
#! Field("BSOC:BSY0:1:PLCHB_calc.INPB",16777215,1,"BSOC:BSY0:1:PLCHB_calc.INPB")
#! Field("BSOC:BSY0:1:PLCHB_calc.OUT",16777215,1,"BSOC:BSY0:1:PLCHB_calc.OUT")
#! Link("BSOC:BSY0:1:PLCHB_calc.OUT","BSOC:BSY0:1:PLCHB.VAL")
#! Record("BSOC:BSY0:1:PLCHB",500,20,0,0,"BSOC:BSY0:1:PLCHB")
#! Field("BSOC:BSY0:1:PLCHB.VAL",16777215,1,"BSOC:BSY0:1:PLCHB.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi116") {
  field(DESC, "Port BSOIC_RD bit 116")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 116, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:1:CHOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:1:CHOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi116 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:1:CHOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:1:CHOK") {
  field(DESC, "BSOIC-CH1_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb116",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb116")
#! Field("PLC:BSY0:BC01:BSOIC_RDb116.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb116.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb116.FLNK","BSOC:BSY0:1:CHOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb116.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb116.VAL")
#! Record("BSOC:BSY0:1:CHOK_calc",260,18,0,1,"BSOC:BSY0:1:CHOK_calc")
#! Field("BSOC:BSY0:1:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:1:CHOK_calc.INPA")
#! Link("BSOC:BSY0:1:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb116.VAL")
#! Field("BSOC:BSY0:1:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:1:CHOK_calc.INPB")
#! Field("BSOC:BSY0:1:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:1:CHOK_calc.OUT")
#! Link("BSOC:BSY0:1:CHOK_calc.OUT","BSOC:BSY0:1:CHOK.VAL")
#! Record("BSOC:BSY0:1:CHOK",500,20,0,0,"BSOC:BSY0:1:CHOK")
#! Field("BSOC:BSY0:1:CHOK.VAL",16777215,1,"BSOC:BSY0:1:CHOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi115") {
  field(DESC, "Port BSOIC_RD bit 115")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 115, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:2:CHOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:2:CHOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi115 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:2:CHOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:2:CHOK") {
  field(DESC, "BSOIC-CH2_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb115",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb115")
#! Field("PLC:BSY0:BC01:BSOIC_RDb115.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb115.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb115.FLNK","BSOC:BSY0:2:CHOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb115.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb115.VAL")
#! Record("BSOC:BSY0:2:CHOK_calc",260,18,0,1,"BSOC:BSY0:2:CHOK_calc")
#! Field("BSOC:BSY0:2:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:2:CHOK_calc.INPA")
#! Link("BSOC:BSY0:2:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb115.VAL")
#! Field("BSOC:BSY0:2:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:2:CHOK_calc.INPB")
#! Field("BSOC:BSY0:2:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:2:CHOK_calc.OUT")
#! Link("BSOC:BSY0:2:CHOK_calc.OUT","BSOC:BSY0:2:CHOK.VAL")
#! Record("BSOC:BSY0:2:CHOK",500,20,0,0,"BSOC:BSY0:2:CHOK")
#! Field("BSOC:BSY0:2:CHOK.VAL",16777215,1,"BSOC:BSY0:2:CHOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi114") {
  field(DESC, "Port BSOIC_RD bit 114")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 114, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:3:CHOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:3:CHOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi114 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:3:CHOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:3:CHOK") {
  field(DESC, "BSOIC-CH3_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb114",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb114")
#! Field("PLC:BSY0:BC01:BSOIC_RDb114.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb114.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb114.FLNK","BSOC:BSY0:3:CHOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb114.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb114.VAL")
#! Record("BSOC:BSY0:3:CHOK_calc",260,18,0,1,"BSOC:BSY0:3:CHOK_calc")
#! Field("BSOC:BSY0:3:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:3:CHOK_calc.INPA")
#! Link("BSOC:BSY0:3:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb114.VAL")
#! Field("BSOC:BSY0:3:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:3:CHOK_calc.INPB")
#! Field("BSOC:BSY0:3:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:3:CHOK_calc.OUT")
#! Link("BSOC:BSY0:3:CHOK_calc.OUT","BSOC:BSY0:3:CHOK.VAL")
#! Record("BSOC:BSY0:3:CHOK",500,20,0,0,"BSOC:BSY0:3:CHOK")
#! Field("BSOC:BSY0:3:CHOK.VAL",16777215,1,"BSOC:BSY0:3:CHOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi113") {
  field(DESC, "Port BSOIC_RD bit 113")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 113, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:4:CHOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:4:CHOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi113 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:4:CHOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:4:CHOK") {
  field(DESC, "BSOIC-CH4_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb113",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb113")
#! Field("PLC:BSY0:BC01:BSOIC_RDb113.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb113.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb113.FLNK","BSOC:BSY0:4:CHOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb113.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb113.VAL")
#! Record("BSOC:BSY0:4:CHOK_calc",260,18,0,1,"BSOC:BSY0:4:CHOK_calc")
#! Field("BSOC:BSY0:4:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:4:CHOK_calc.INPA")
#! Link("BSOC:BSY0:4:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb113.VAL")
#! Field("BSOC:BSY0:4:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:4:CHOK_calc.INPB")
#! Field("BSOC:BSY0:4:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:4:CHOK_calc.OUT")
#! Link("BSOC:BSY0:4:CHOK_calc.OUT","BSOC:BSY0:4:CHOK.VAL")
#! Record("BSOC:BSY0:4:CHOK",500,20,0,0,"BSOC:BSY0:4:CHOK")
#! Field("BSOC:BSY0:4:CHOK.VAL",16777215,1,"BSOC:BSY0:4:CHOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi112") {
  field(DESC, "Port BSOIC_RD bit 112")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 112, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:5:CHOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:5:CHOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi112 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:5:CHOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:5:CHOK") {
  field(DESC, "BSOIC-CH5_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb112",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb112")
#! Field("PLC:BSY0:BC01:BSOIC_RDb112.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb112.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb112.FLNK","BSOC:BSY0:5:CHOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb112.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb112.VAL")
#! Record("BSOC:BSY0:5:CHOK_calc",260,18,0,1,"BSOC:BSY0:5:CHOK_calc")
#! Field("BSOC:BSY0:5:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:5:CHOK_calc.INPA")
#! Link("BSOC:BSY0:5:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb112.VAL")
#! Field("BSOC:BSY0:5:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:5:CHOK_calc.INPB")
#! Field("BSOC:BSY0:5:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:5:CHOK_calc.OUT")
#! Link("BSOC:BSY0:5:CHOK_calc.OUT","BSOC:BSY0:5:CHOK.VAL")
#! Record("BSOC:BSY0:5:CHOK",500,20,0,0,"BSOC:BSY0:5:CHOK")
#! Field("BSOC:BSY0:5:CHOK.VAL",16777215,1,"BSOC:BSY0:5:CHOK.VAL")
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND



record(bi, "PLC:BSY0:BC01:Bi127") {
  field(DESC, "Port BSOIC_RD bit 127")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_RD, 127, 1, 1)")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(FLNK, "BSOC:BSY0:6:CHOK_calc PP MS")
  field(ASG,  "Internal")
}

record(calcout, "BSOC:BSY0:6:CHOK_calc") {
  field(INPA, "PLC:BSY0:BC01:Bi127 NPP MS")
  field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "BSOC:BSY0:6:CHOK PP MS")
  field(ASG,  "Internal")
}

record(bi, "BSOC:BSY0:6:CHOK") {
  field(DESC, "BSOIC-CH6_OK")
  field(ZNAM, "Fault")
  field(ONAM, "Ok")
  field(ZSV, "MAJOR")
  field(OSV, "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("PLC:BSY0:BC01:BSOIC_RDb127",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb127")
#! Field("PLC:BSY0:BC01:BSOIC_RDb127.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb127.FLNK")
#! Link("PLC:BSY0:BC01:BSOIC_RDb127.FLNK","BSOC:BSY0:6:CHOK_calc")
#! Field("PLC:BSY0:BC01:BSOIC_RDb127.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb127.VAL")
#! Record("BSOC:BSY0:6:CHOK_calc",260,18,0,1,"BSOC:BSY0:6:CHOK_calc")
#! Field("BSOC:BSY0:6:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:6:CHOK_calc.INPA")
#! Link("BSOC:BSY0:6:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb127.VAL")
#! Field("BSOC:BSY0:6:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:6:CHOK_calc.INPB")
#! Field("BSOC:BSY0:6:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:6:CHOK_calc.OUT")
#! Link("BSOC:BSY0:6:CHOK_calc.OUT","BSOC:BSY0:6:CHOK.VAL")
#! Record("BSOC:BSY0:6:CHOK",500,20,0,0,"BSOC:BSY0:6:CHOK")
#! Field("BSOC:BSY0:6:CHOK.VAL",16777215,1,"BSOC:BSY0:6:CHOK.VAL")
record(bo, "BSOC:BSY0:1:SRESET") {
  field(DESC, "BSOIC-Soft_Reset_G1")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 7, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:3:SRESET") {
  field(DESC, "BSOIC-Soft_Reset_G2")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 6, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:4:SRESET") {
  field(DESC, "BSOIC-Soft_Reset_G3")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 5, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:5:SRESET") {
  field(DESC, "BSOIC-Soft_Reset_G4")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 4, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:2:SRESET") {
  field(DESC, "BSOIC-Soft_Reset_N1")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 3, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:6:SRESET") {
  field(DESC, "BSOIC-Soft_Reset_N2")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 2, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:1:SRESET_ALL") {
  field(DESC, "BSOIC-Soft_Reset_All")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 1, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Reset")
   field(ASG,  "MCC")
}

record(bo, "BSOC:BSY0:1:SPAUSEHB") {
  field(DESC, "BSOIC-Soft_Pause_Hb")
  field(DTYP, "asynUInt32Digital")
  field(OUT,  "@asynMask(BSOIC_WRT, 0, 1, 1)")
  field(ZNAM, "Off")
  field(ONAM, "Pause")
   field(ASG,  "MCC")
}

#==============================================================================
#
# Abs:  PILZ PNOZ PLC interface for accessing the right table/segment
#
# Name: pilz-plc-request.template
#
# Facility: LCLS Personnel Protection Controls
#
# Auth: 11-Dec-2018, Garth Brown   (GWBROWN)
# Rev : dd-mmm-yyyy, Reviewer's Name  (USERNAME)
#
# To specify which registers to read/write, you need to set the table and
# segment (see PNOZ docs). This set of PVs keeps them set to the correct values
# for reading either virtual I/O points or program stats such as project checksum.
# The PNOZ PLC also has occasional communications dropouts, where the PLC stops
# responding and the TCP connection must be reset. This happens more frequently
# the more communication there is with the PLC.
# While the vendor offers a PNOZ model with integrated Ethernet port which
# allows readback at different modbus addresses instead of needing to set
# table/segment, that interface also allows remote access to secure registers
# and PLC programming. For safety, that type of remote access is not allowed in
# our system. All of their products that don't allow remote access beyond our
# safety specs also require table/segment setting to choose which registers to
# read/write.
#
#-----------------------------------------------------------------------------
#  Mod:
#
#==============================================================================
#

record(longout, "PLC:BSY0:BC01:REQ_TABLE") {
	field(DESC, "Table to read/write")
	field(VAL, "9")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_OUT PP")
	field(HOPR, "128")
	field(LOPR, "0")
	field(PINI, "YES")
	info(autosaveFields, "VAL")
}

# All the data we're interested in is: Tables 1 and 9, segment 1
# We only need table 1 once for check sums that don't change, so
# read it for a short time during startup, then switch to table 9.
record(calcout, "PLC:BSY0:BC01:TABLE_CYCLER")
{
	field( OUT, "PLC:BSY0:BC01:REQ_TABLE PP")
	field( CALC, "A:=(A+1)%3600;A=20?1:9")
	field( INPA, "0")
	field( SCAN, ".5 second")
}

record(calcout, "PLC:BSY0:BC01:SEG_CYCLER")
{
	field( OUT, "PLC:BSY0:BC01:REQ_SEG PP")
	field( CALC, "1")
	field( INPA, "0")
	field( SCAN, ".5 second")
}

# Records for disabling PVs when their reqest table isn't active
record(calc, "PLC:BSY0:BC01:TABLE_9_SEG_1")
{
	field( INPA, "PLC:BSY0:BC01:REQ_TABLE CP")
	field( INPB, "PLC:BSY0:BC01:REQ_SEG CP")
	field( INPC, "PLC:BSY0:BC01:REQ_TABLE_IN CP")
	field( INPD, "PLC:BSY0:BC01:REQ_SEG_IN CP")
	field(CALC, "A=9 & B=1 & C=9 & D=1")
}

record(calc, "PLC:BSY0:BC01:TABLE_1_SEG_1")
{
	field( INPA, "PLC:BSY0:BC01:REQ_TABLE CP")
	field( INPB, "PLC:BSY0:BC01:REQ_SEG CP")
	field( INPC, "PLC:BSY0:BC01:REQ_TABLE_IN CP")
	field( INPD, "PLC:BSY0:BC01:REQ_SEG_IN CP")
	field(CALC, "A=1 & B=1 & C=1 & D=1")
}

# The target PVs don't use the data, but this has 8 forward links,
# the number we need, while the fanout record only has 6.
record(dfanout, "PLC:BSY0:BC01:REQ_TABLE_OUT") {
	field(OUTA, "PLC:BSY0:BC01:REQ_TABLE_BIT0_CALC.A PP")
	field(OUTB, "PLC:BSY0:BC01:REQ_TABLE_BIT1_CALC.A PP")
	field(OUTC, "PLC:BSY0:BC01:REQ_TABLE_BIT2_CALC.A PP")
	field(OUTD, "PLC:BSY0:BC01:REQ_TABLE_BIT3_CALC.A PP")
	field(OUTE, "PLC:BSY0:BC01:REQ_TABLE_BIT4_CALC.A PP")
	field(OUTF, "PLC:BSY0:BC01:REQ_TABLE_BIT5_CALC.A PP")
	field(OUTG, "PLC:BSY0:BC01:REQ_TABLE_BIT6_CALC.A PP")
	field(OUTH, "PLC:BSY0:BC01:REQ_TABLE_BIT7_CALC.A PP")
	field(SDIS, "PLC:BSY0:BC01:REQ_TABLE_IN.PACT")
}

# The simpler approach of writing to the table/segment every few seconds caused
# TCP dropouts to happen several times an hour, compared to every day or two
# when we only ever read/wrote table 9 segment 1. These calcout records reduce
# the dropouts to around 5 a day by only writing the bits that need to change.

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT0_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT0 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT0 MS")
	field(CALC, "(B#C)||(B#(A&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "A&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT0 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT1_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT1 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT1 MS")
	field(CALC, "(B#C)||(B#((A>>1)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>1)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT1 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT2_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT2 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT2 MS")
	field(CALC, "(B#C)||(B#((A>>2)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>2)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT2 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT3_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT3 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT3 MS")
	field(CALC, "(B#C)||(B#((A>>3)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>3)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT3 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT4_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT4 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT4 MS")
	field(CALC, "(B#C)||(B#((A>>4)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>4)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT4 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT5_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT5 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT5 MS")
	field(CALC, "(B#C)||(B#((A>>5)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>5)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT5 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT6_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT6 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT6 MS")
	field(CALC, "(B#C)||(B#((A>>6)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>6)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT6 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT7_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT7 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT7 MS")
	field(CALC, "(B#C)||(B#((A>>7)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>7)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT7 PP")
}


record(calcout, "PLC:BSY0:BC01:REQ_TABLE_IN") {
	field(DESC, "Table readback")
	field(INPA, "PLC:BSY0:BC01:TABLE_BIT0 CP MS")
	field(INPB, "PLC:BSY0:BC01:TABLE_BIT1 CP MS")
	field(INPC, "PLC:BSY0:BC01:TABLE_BIT2 CP MS")
	field(INPD, "PLC:BSY0:BC01:TABLE_BIT3 CP MS")
	field(INPE, "PLC:BSY0:BC01:TABLE_BIT4 CP MS")
	field(INPF, "PLC:BSY0:BC01:TABLE_BIT5 CP MS")
	field(INPG, "PLC:BSY0:BC01:TABLE_BIT6 CP MS")
	field(INPH, "PLC:BSY0:BC01:TABLE_BIT7 CP MS")
	field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128")
	field(OUT, "PLC:BSY0:BC01:REQ_TABLE PP MS")
	#field(SDIS, "PLC:BSY0:BC01:REQ_TABLE_OUT.PACT")
}


record(longout, "PLC:BSY0:BC01:REQ_SEG") {
	field(DESC, "Segment to read/write")
	field(VAL, "1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_OUT PP")
	field(HOPR, "128")
	field(LOPR, "0")
	field(PINI, "YES")
	info(autosaveFields, "VAL")
}

# The target PVs don't use the data, but this has 8 forward links,
# the number we need, while the fanout record only has 6.
record(dfanout, "PLC:BSY0:BC01:REQ_SEG_OUT") {
	field(OUTA, "PLC:BSY0:BC01:REQ_SEG_BIT0_CALC.A PP")
	field(OUTB, "PLC:BSY0:BC01:REQ_SEG_BIT1_CALC.A PP")
	field(OUTC, "PLC:BSY0:BC01:REQ_SEG_BIT2_CALC.A PP")
	field(OUTD, "PLC:BSY0:BC01:REQ_SEG_BIT3_CALC.A PP")
	field(OUTE, "PLC:BSY0:BC01:REQ_SEG_BIT4_CALC.A PP")
	field(OUTF, "PLC:BSY0:BC01:REQ_SEG_BIT5_CALC.A PP")
	field(OUTG, "PLC:BSY0:BC01:REQ_SEG_BIT6_CALC.A PP")
	field(OUTH, "PLC:BSY0:BC01:REQ_SEG_BIT7_CALC.A PP")
	field(SDIS, "PLC:BSY0:BC01:REQ_SEG_IN.PACT")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT0_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT0 CP MS")
	field(CALC, "(B#C)||(B#(A&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "A&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT0 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT1_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT1 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT1 MS")
	field(CALC, "(B#C)||(B#((A>>1)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>1)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT1 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT2_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT2 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT2 MS")
	field(CALC, "(B#C)||(B#((A>>2)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>2)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT2 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT3_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT3 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT3 MS")
	field(CALC, "(B#C)||(B#((A>>3)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>3)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT3 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT4_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT4 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT4 MS")
	field(CALC, "(B#C)||(B#((A>>4)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>4)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT4 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT5_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT5 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT5 MS")
	field(CALC, "(B#C)||(B#((A>>5)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>5)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT5 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT6_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT6 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT6 MS")
	field(CALC, "(B#C)||(B#((A>>6)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>6)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT6 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT7_CALC") {
	field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT7 MS")
	field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT7 MS")
	field(CALC, "(B#C)||(B#((A>>7)&1))")
	field(DOPT, "Use OCAL")
	field(OOPT, "When Non-zero")
	field(OCAL, "(A>>7)&1")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT7 PP")
}

record(calcout, "PLC:BSY0:BC01:REQ_SEG_IN") {
	field(DESC, "Segment readback")
	field(INPA, "PLC:BSY0:BC01:SEG_BIT0 CP MS")
	field(INPB, "PLC:BSY0:BC01:SEG_BIT1 CP MS")
	field(INPC, "PLC:BSY0:BC01:SEG_BIT2 CP MS")
	field(INPD, "PLC:BSY0:BC01:SEG_BIT3 CP MS")
	field(INPE, "PLC:BSY0:BC01:SEG_BIT4 CP MS")
	field(INPF, "PLC:BSY0:BC01:SEG_BIT5 CP MS")
	field(INPG, "PLC:BSY0:BC01:SEG_BIT6 CP MS")
	field(INPH, "PLC:BSY0:BC01:SEG_BIT7 CP MS")
	field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128")
	field(OUT, "PLC:BSY0:BC01:REQ_SEG PP MS")
	field(SDIS, "PLC:BSY0:BC01:REQ_SEG_OUT.PACT")
}

record(bi, "PLC:BSY0:BC01:LED_X1") {
	field(DESC, "PPS-X1_LED")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 24, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "MAJOR")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:LED_X2") {
	field(DESC, "PPS-X2_LED")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 25, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "MAJOR")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:PWLED") {
	field(DESC, "ODM-Power_LED_A")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 26, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "MAJOR")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:RUNLED") {
	field(DESC, "ODM-Run_LED_A")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 27, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "MAJOR")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:DIAGLED") {
	field(DESC, "ODM-Diag_LED_A")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 28, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:FAULTLED") {
	field(DESC, "ODM-Fault_LED_A")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 29, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:IFAULTLED") {
	field(DESC, "ODM-IFault_LED_A")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 30, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:OFAULTLED") {
	field(DESC, "ODM-OFault_LED_A")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 31, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "MAJOR")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT7") {
	field(DESC, "Table Read bit 7")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 32, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT6") {
	field(DESC, "Table Read bit 6")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 33, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT5") {
	field(DESC, "Table Read bit 5")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 34, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT4") {
	field(DESC, "Table Read bit 4")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 35, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT3") {
	field(DESC, "Table Read bit 3")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 36, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT2") {
	field(DESC, "Table Read bit 2")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 37, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT1") {
	field(DESC, "Table Read bit 1")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 38, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:TABLE_BIT0") {
	field(DESC, "Table Read bit 0")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 39, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT7") {
	field(DESC, "Segment Read bit 7")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 40, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT6") {
	field(DESC, "Segment Read bit 6")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 41, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT5") {
	field(DESC, "Segment Read bit 5")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 42, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT4") {
	field(DESC, "Segment Read bit 4")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 43, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT3") {
	field(DESC, "Segment Read bit 3")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 44, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT2") {
	field(DESC, "Segment Read bit 2")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 45, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT1") {
	field(DESC, "Segment Read bit 1")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 46, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}

record(bi, "PLC:BSY0:BC01:SEG_BIT0") {
	field(DESC, "Segment Read bit 0")
	field(SCAN, "I/O Intr")
	field(DTYP, "asynUInt32Digital")
	field(INP,  "@asynMask(BSOIC_RD, 47, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
	field(ZSV,  "NO_ALARM")
	field(OSV,  "NO_ALARM")
  info(autosaveFields_pass0, "SEVR")
}


record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT7") {
	field(DESC, "Table Request bit 7")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 32, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT6") {
	field(DESC, "Table Request bit 6")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 33, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT5") {
	field(DESC, "Table Request bit 5")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 34, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT4") {
	field(DESC, "Table Request bit 4")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 35, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT3") {
	field(DESC, "Table Request bit 3")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 36, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT2") {
	field(DESC, "Table Request bit 2")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 37, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT1") {
	field(DESC, "Table Request bit 1")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 38, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT0") {
	field(DESC, "Table Request bit 0")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 39, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT7") {
	field(DESC, "Segment Request bit 7")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 40, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT6") {
	field(DESC, "Segment Request bit 6")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 41, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT5") {
	field(DESC, "Segment Request bit 5")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 42, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT4") {
	field(DESC, "Segment Request bit 4")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 43, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT3") {
	field(DESC, "Segment Request bit 3")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 44, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT2") {
	field(DESC, "Segment Request bit 2")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 45, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT1") {
	field(DESC, "Segment Request bit 1")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 46, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}

record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT0") {
	field(DESC, "Segment Request bit 0")
	field(DTYP, "asynUInt32Digital")
	field(OUT,  "@asynMask(BSOIC_WRT, 47, 1, 1)")
	field(ZNAM, "Off")
	field(ONAM, "On")
}
#! Generated by VisualDCT v2.7.0
#! DBDSTART
#! DBDEND


record(longin, "PLC:BSY0:BC01:w0") {
  field(DESC, "Checksum word 0")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 0, 0xFFFF, 1)")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:w1") {
  field(DESC, "Checksum word 1")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 1, 0xFFFF, 1)")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:w2") {
  field(DESC, "Active Table and Segment")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 2, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:CHECKSUM_SDIS PP MS")
  field(ASG,  "Internal")
}

record(calc, "PLC:BSY0:BC01:CHECKSUM_SDIS") {
  field(INPA, "PLC:BSY0:BC01:w2 NPP MS")
  field(CALC, "A = 0X0101")
}

record(longin, "PLC:BSY0:BC01:w3") {
  field(DESC, "Checksum word 3")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 3, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:CHECKSUM_SAFE PP MS")
  field(ASG,  "Internal")
}

record(calcout, "PLC:BSY0:BC01:CHECKSUM_SAFE_calc") {
  field(INPA, "PLC:BSY0:BC01:w3 PP MS")
  field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS PP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "PLC:BSY0:BC01:CHECKSUM_SAFE PP MS")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:CHECKSUM_SAFE") {
  field(DESC, "Check Sum Safe")
  field(FLNK, "PLC:BSY0:BC01:CHECKSUM_SAFE_calc PP MS")
  info(autosaveFields_pass0, "VAL")
}

record(longin, "PLC:BSY0:BC01:w4") {
  field(DESC, "Checksum word 4")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 4, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:PROJ_CHECKSUM_calc")
  field(ASG,  "Internal")
}

record(calcout, "PLC:BSY0:BC01:PROJ_CHECKSUM_calc") {
  field(INPA, "PLC:BSY0:BC01:w4 NPP MS")
  field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "PLC:BSY0:BC01:PROJ_CHECKSUM PP MS")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:PROJ_CHECKSUM") {
  field(DESC, "Total Project Check Sum")
  info(autosaveFields_pass0, "VAL")
}

record(longin, "PLC:BSY0:BC01:w5") {
  field(DESC, "Checksum word 5")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 5, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:DAY_MONTH_calc")
  field(ASG,  "Internal")
}

record(calcout, "PLC:BSY0:BC01:DAY_MONTH_calc") {
  field(INPA, "PLC:BSY0:BC01:w5 NPP MS")
  field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "PLC:BSY0:BC01:DAY_MONTH PP MS")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:DAY_MONTH") {
  field(DESC, "Raw day and month")
  field(ASG,  "Internal")
}

record(calc, "PLC:BSY0:BC01:PROJ_MONTH") {
  field(DESC, "Project creation day")
  field(INPA, "PLC:BSY0:BC01:DAY_MONTH CP MS")
  field(CALC, "A & 0xFF")
  info(autosaveFields_pass0, "VAL")
}

record(calc, "PLC:BSY0:BC01:PROJ_DAY") {
  field(DESC, "Project creation month")
  field(INPA, "PLC:BSY0:BC01:DAY_MONTH CP MS")
  field(CALC, "A >> 8")
  info(autosaveFields_pass0, "VAL")
}

record(longin, "PLC:BSY0:BC01:w6") {
  field(DESC, "Checksum word 6")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 6, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:PROJ_YEAR_calc")
  field(ASG,  "Internal")
}

record(calcout, "PLC:BSY0:BC01:PROJ_YEAR_calc") {
  field(INPA, "PLC:BSY0:BC01:w6 NPP MS")
  field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "PLC:BSY0:BC01:PROJ_YEAR PP MS")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:PROJ_YEAR") {
  field(DESC, "Project creation year.")
  info(autosaveFields_pass0, "VAL")
}

record(longin, "PLC:BSY0:BC01:w7") {
  field(DESC, "Checksum word 7")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 7, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:OP_HRS_MSB_calc")
  field(ASG,  "Internal")
}

record(calcout, "PLC:BSY0:BC01:OP_HRS_MSB_calc") {
  field(INPA, "PLC:BSY0:BC01:w7 NPP MS")
  field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "PLC:BSY0:BC01:OP_HRS_MSB PP MS")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:OP_HRS_MSB") {
  field(DESC, "Operation hours upper byte")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:w8") {
  field(DESC, "Checksum word 8")
  field(SCAN, "I/O Intr")
  field(DTYP, "asynUInt32Digital")
  field(INP, "@asynMask(BSOIC_WD, 8, 0xFFFF, 1)")
  field(FLNK, "PLC:BSY0:BC01:OP_HRS_LSB_calc")
  field(ASG,  "Internal")
}

record(calcout, "PLC:BSY0:BC01:OP_HRS_LSB_calc") {
  field(INPA, "PLC:BSY0:BC01:w8 NPP MS")
  field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS")
  field(CALC, "B")
  field(OCAL, "A")
  field(DOPT, "Use OCAL")
  field(OOPT, "When Non-zero")
  field(OUT, "PLC:BSY0:BC01:OP_HRS_LSB PP MS")
  field(ASG,  "Internal")
}

record(longin, "PLC:BSY0:BC01:OP_HRS_LSB") {
  field(DESC, "Operation hours lower byte")
  field(ASG,  "Internal")
}

record(calc, "PLC:BSY0:BC01:OP_HOURS") {
  field(INPA, "PLC:BSY0:BC01:OP_HRS_MSB CP MS")
  field(INPB, "PLC:BSY0:BC01:OP_HRS_LSB CP MS")
  field(CALC, "(A << 8)+(B>>8)")
  info(autosaveFields_pass0, "VAL")
}

record(mbbi, "PLC:BSY0:BC01:BASE_MODEL") {
  field(DTYP, "Raw Soft Channel")
  field(NOBT, "8")
  field(INP, "PLC:BSY0:BC01:OP_HRS_LSB CP MS")
  field(ZRVL, "0x00")
  field(ONVL, "0x02")
  field(TWVL, "0x04")
  field(THVL, "0x03")
  field(FRVL, "0x20")
  field(FVVL, "0x22")
  field(SXVL, "0x24")
  field(SVVL, "0x23")
  field(EIVL, "0x50")
  field(NIVL, "0x51")
  field(TEVL, "0x52")
  field(ZRST, "PNOZ m1p")
  field(ONST, "PNOZ m0p")
  field(TWST, "PNOZ m2p")
  field(THST, "PNOZ m3p")
  field(FRST, "PNOZ m1p ETH")
  field(FVST, "PNOZ m0p ETH")
  field(SXST, "PNOZ m2p ETH")
  field(SVST, "PNOZ m3p ETH")
  field(EIST, "PNOZ mm0p")
  field(NIST, "PNOZ mm0.1p")
  field(TEST, "PNOZ mm0.2p")
}

# End of file
# Template for I/O statistics

record(bo,"PLC:BSY0:BC01:RDHistEnable") {
    field(DTYP,"asynUInt32Digital")
    field(OUT,"@asynMask(BSOIC_RD 0 0xFFFF)ENABLE_HISTOGRAM")
    field(ZNAM,"Disable")
    field(ONAM,"Enable")
}

record(bo, "PLC:BSY0:BC01:RDStatistics") {
    field(SCAN, "10 second")
    field(FLNK, "PLC:BSY0:BC01:RDHist.PROC")
}

record(waveform,"PLC:BSY0:BC01:RDHist") {
    field(DTYP,"asynInt32ArrayIn")
    field(INP,"@asyn(BSOIC_RD 0)READ_HISTOGRAM")
    field(FTVL,"LONG")
    field(NELM,"200")  # This number should match driver
    field(FLNK,"PLC:BSY0:BC01:RDHistTimeAxis.PROC")
}

record(waveform,"PLC:BSY0:BC01:RDHistTimeAxis") {
    field(DTYP,"asynInt32ArrayIn")
    field(INP,"@asyn(BSOIC_RD 0)HISTOGRAM_TIME_AXIS")
    field(FTVL,"LONG")
    field(NELM,"200")  # This number should match driver
    field(FLNK,"PLC:BSY0:BC01:RDReadOK.PROC")
}

record(longout,"PLC:BSY0:BC01:RDMsPerBin") {
    field(DTYP,"asynInt32")
    field(OUT,"@asyn(BSOIC_RD 0)HISTOGRAM_BIN_TIME")
    field(DRVL,"0")
    field(VAL,"1")
    field(PINI,"1")
}

record(longin,"PLC:BSY0:BC01:RDReadOK") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_RD 0)READ_OK")
    field(FLNK,"PLC:BSY0:BC01:RDWriteOK.PROC")
}

record(longin,"PLC:BSY0:BC01:RDWriteOK") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_RD 0)WRITE_OK")
    field(FLNK,"PLC:BSY0:BC01:RDIOErrors.PROC")
}

record(longin,"PLC:BSY0:BC01:RDIOErrors") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_RD 0)IO_ERRORS")
    field(FLNK,"PLC:BSY0:BC01:RDLastIOTime.PROC")
}

record(longin,"PLC:BSY0:BC01:RDLastIOTime") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_RD 0)LAST_IO_TIME")
    field(FLNK,"PLC:BSY0:BC01:RDMaxIOTime.PROC")
}

record(longin,"PLC:BSY0:BC01:RDMaxIOTime") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_RD 0)MAX_IO_TIME")
}
# Template for I/O statistics

record(bo,"PLC:BSY0:BC01:WRTHistEnable") {
    field(DTYP,"asynUInt32Digital")
    field(OUT,"@asynMask(BSOIC_WRT 0 0xFFFF)ENABLE_HISTOGRAM")
    field(ZNAM,"Disable")
    field(ONAM,"Enable")
}

record(bo, "PLC:BSY0:BC01:WRTStatistics") {
    field(SCAN, "10 second")
    field(FLNK, "PLC:BSY0:BC01:WRTHist.PROC")
}

record(waveform,"PLC:BSY0:BC01:WRTHist") {
    field(DTYP,"asynInt32ArrayIn")
    field(INP,"@asyn(BSOIC_WRT 0)READ_HISTOGRAM")
    field(FTVL,"LONG")
    field(NELM,"200")  # This number should match driver
    field(FLNK,"PLC:BSY0:BC01:WRTHistTimeAxis.PROC")
}

record(waveform,"PLC:BSY0:BC01:WRTHistTimeAxis") {
    field(DTYP,"asynInt32ArrayIn")
    field(INP,"@asyn(BSOIC_WRT 0)HISTOGRAM_TIME_AXIS")
    field(FTVL,"LONG")
    field(NELM,"200")  # This number should match driver
    field(FLNK,"PLC:BSY0:BC01:WRTReadOK.PROC")
}

record(longout,"PLC:BSY0:BC01:WRTMsPerBin") {
    field(DTYP,"asynInt32")
    field(OUT,"@asyn(BSOIC_WRT 0)HISTOGRAM_BIN_TIME")
    field(DRVL,"0")
    field(VAL,"1")
    field(PINI,"1")
}

record(longin,"PLC:BSY0:BC01:WRTReadOK") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WRT 0)READ_OK")
    field(FLNK,"PLC:BSY0:BC01:WRTWriteOK.PROC")
}

record(longin,"PLC:BSY0:BC01:WRTWriteOK") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WRT 0)WRITE_OK")
    field(FLNK,"PLC:BSY0:BC01:WRTIOErrors.PROC")
}

record(longin,"PLC:BSY0:BC01:WRTIOErrors") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WRT 0)IO_ERRORS")
    field(FLNK,"PLC:BSY0:BC01:WRTLastIOTime.PROC")
}

record(longin,"PLC:BSY0:BC01:WRTLastIOTime") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WRT 0)LAST_IO_TIME")
    field(FLNK,"PLC:BSY0:BC01:WRTMaxIOTime.PROC")
}

record(longin,"PLC:BSY0:BC01:WRTMaxIOTime") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WRT 0)MAX_IO_TIME")
}
# Template for I/O statistics

record(bo,"PLC:BSY0:BC01:WDHistEnable") {
    field(DTYP,"asynUInt32Digital")
    field(OUT,"@asynMask(BSOIC_WD 0 0xFFFF)ENABLE_HISTOGRAM")
    field(ZNAM,"Disable")
    field(ONAM,"Enable")
}

record(bo, "PLC:BSY0:BC01:WDStatistics") {
    field(SCAN, "10 second")
    field(FLNK, "PLC:BSY0:BC01:WDHist.PROC")
}

record(waveform,"PLC:BSY0:BC01:WDHist") {
    field(DTYP,"asynInt32ArrayIn")
    field(INP,"@asyn(BSOIC_WD 0)READ_HISTOGRAM")
    field(FTVL,"LONG")
    field(NELM,"200")  # This number should match driver
    field(FLNK,"PLC:BSY0:BC01:WDHistTimeAxis.PROC")
}

record(waveform,"PLC:BSY0:BC01:WDHistTimeAxis") {
    field(DTYP,"asynInt32ArrayIn")
    field(INP,"@asyn(BSOIC_WD 0)HISTOGRAM_TIME_AXIS")
    field(FTVL,"LONG")
    field(NELM,"200")  # This number should match driver
    field(FLNK,"PLC:BSY0:BC01:WDReadOK.PROC")
}

record(longout,"PLC:BSY0:BC01:WDMsPerBin") {
    field(DTYP,"asynInt32")
    field(OUT,"@asyn(BSOIC_WD 0)HISTOGRAM_BIN_TIME")
    field(DRVL,"0")
    field(VAL,"1")
    field(PINI,"1")
}

record(longin,"PLC:BSY0:BC01:WDReadOK") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WD 0)READ_OK")
    field(FLNK,"PLC:BSY0:BC01:WDWriteOK.PROC")
}

record(longin,"PLC:BSY0:BC01:WDWriteOK") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WD 0)WRITE_OK")
    field(FLNK,"PLC:BSY0:BC01:WDIOErrors.PROC")
}

record(longin,"PLC:BSY0:BC01:WDIOErrors") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WD 0)IO_ERRORS")
    field(FLNK,"PLC:BSY0:BC01:WDLastIOTime.PROC")
}

record(longin,"PLC:BSY0:BC01:WDLastIOTime") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WD 0)LAST_IO_TIME")
    field(FLNK,"PLC:BSY0:BC01:WDMaxIOTime.PROC")
}

record(longin,"PLC:BSY0:BC01:WDMaxIOTime") {
    field(DTYP,"asynInt32")
    field(INP,"@asyn(BSOIC_WD 0)MAX_IO_TIME")
}


# LCLS alarming template for the BSY BSOICs factoring in bypass mode.
record(calcout, "BSOC:BSY0:4:CALCALARMSUM") {
  field(SCAN, "2 second")
  field(CALC, "(!B)*A")
  field(INPA, "BSOC:BSY0:4:CHOK.SEVR MS")
  field(INPB, "BSOC:BSY0:1:MODE")
  field(OUT, "BSOC:BSY0:4:ALARMSUM PP")
  field(OOPT, "Every Time")
}

record(mbbi, "BSOC:BSY0:4:ALARMSUM") {
  field(DESC, "BSOC:BSY0:4 alarm sum")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(ZRST, "NO_ALARM")
  field(ONST, "MINOR")
  field(TWST, "MAJOR")
  field(THST, "INVALID")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
}



# LCLS alarming template for the BSY BSOICs factoring in bypass mode.
record(calcout, "BSOC:BSY0:6:CALCALARMSUM") {
  field(SCAN, "2 second")
  field(CALC, "(!B)*A")
  field(INPA, "BSOC:BSY0:6:CHOK.SEVR MS")
  field(INPB, "BSOC:BSY0:1:MODE")
  field(OUT, "BSOC:BSY0:6:ALARMSUM PP")
  field(OOPT, "Every Time")
}

record(mbbi, "BSOC:BSY0:6:ALARMSUM") {
  field(DESC, "BSOC:BSY0:6 alarm sum")
  field(ZRVL, "0")
  field(ONVL, "1")
  field(TWVL, "2")
  field(THVL, "3")
  field(ZRST, "NO_ALARM")
  field(ONST, "MINOR")
  field(TWST, "MAJOR")
  field(THST, "INVALID")
  field(ZRSV, "NO_ALARM")
  field(ONSV, "MINOR")
  field(TWSV, "MAJOR")
  field(THSV, "INVALID")
}