record(bi, "PPS:BSY0:1:S7_STATUS") { field(DTYP, "S7plc stat") field(INP, "@PPS_BSY0_PLC") field(SCAN, "I/O Intr") field(ZNAM, "Disconnected") field(ONAM, "Connected") field(ZSV, "MAJOR") field(FLNK, "PPS:BSY0:1:S7_STAT_COUNTER") } record(calc, "PPS:BSY0:1:S7_STAT_COUNTER") { field(INPA, "PPS:BSY0:1:S7_STAT_COUNTER") field(CALC, "A+1") field(FLNK, "PPS:BSY0:1:S7_DISCONNECT_COUNTER") } record(calc, "PPS:BSY0:1:S7_DISCONNECT_COUNTER") { field(INPA, "PPS:BSY0:1:S7_STATUS") field(INPB, "PPS:BSY0:1:S7_DISCONNECT_COUNTER.LA") field(INPC, "PPS:BSY0:1:S7_DISCONNECT_COUNTER") field(CALC, "(A=0&&B=1)?C+1:C") } record(ai, "BSOC:BSY0:1:GAMMAPLC") { field(DESC, "BSOIC_Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/454 T=DWORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:1:GAMMARAW") } record(calcout, "BSOC:BSY0:1:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:BSY0:1:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:1:GAMMAACT") } record(calcout, "BSOC:BSY0:1:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:BSY0:1:GAMMARAW") field(INPB, "1.0") field(EGU, "mr/hour") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9.0") field(HIGH, "7.0") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") } record(ai, "BSOC:BSY0:3:GAMMAPLC") { field(DESC, "BSOIC_Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/456 T=DWORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:3:GAMMARAW") } record(calcout, "BSOC:BSY0:3:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3740") field(INPA, "BSOC:BSY0:3:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:3:GAMMAACT") } record(calcout, "BSOC:BSY0:3:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:BSY0:3:GAMMARAW") field(INPB, "1.0") field(EGU, "mr/hour") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9.0") field(HIGH, "7.0") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") } record(ai, "BSOC:BSY0:4:GAMMAPLC") { field(DESC, "BSOIC_Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/458 T=DWORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:4:GAMMARAW") } record(calcout, "BSOC:BSY0:4:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3740") field(INPA, "BSOC:BSY0:4:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:4:GAMMAACT") } record(calcout, "BSOC:BSY0:4:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:BSY0:4:GAMMARAW") field(INPB, "1.0") field(EGU, "mr/hour") field(HOPR, "10") field(LOPR, "0") field(HIHI, "7.0") field(HIGH, "4.9") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") } record(ai, "BSOC:BSY0:5:GAMMAPLC") { field(DESC, "BSOIC_Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/460 T=DWORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:5:GAMMARAW") } record(calcout, "BSOC:BSY0:5:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3740") field(INPA, "BSOC:BSY0:5:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:BSY0:5:GAMMAACT") } record(calcout, "BSOC:BSY0:5:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:BSY0:5:GAMMARAW") field(INPB, "1.0") field(EGU, "mr/hour") field(HOPR, "10") field(LOPR, "0") field(HIHI, "7.0") field(HIGH, "4.9") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:BSY0:1:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:BSY0:1:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:BSY0:1:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:BSY0:1:WARNINGMODE") field(INPB, "BSOC:BSY0:1:GAMMAACT.SEVR") field(HIHI, "1") field(HHSV, "MINOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:BSY0:1:WARNINGMODE",3440,3386,0,1,"BSOC:BSY0:1:WARNINGMODE") #! Field("BSOC:BSY0:1:WARNINGMODE.VAL",16777215,1,"BSOC:BSY0:1:WARNINGMODE.VAL") #! Field("BSOC:BSY0:1:WARNINGMODE.FLNK",16777215,1,"BSOC:BSY0:1:WARNINGMODE.FLNK") #! Link("BSOC:BSY0:1:WARNINGMODE.FLNK","BSOC:BSY0:1:CALCWARNING") #! Record("BSOC:BSY0:1:CALCWARNING",3760,3400,0,0,"BSOC:BSY0:1:CALCWARNING") #! Field("BSOC:BSY0:1:CALCWARNING.INPA",16777215,0,"BSOC:BSY0:1:CALCWARNING.INPA") #! Link("BSOC:BSY0:1:CALCWARNING.INPA","BSOC:BSY0:1:WARNINGMODE.VAL") #! Field("BSOC:BSY0:1:CALCWARNING.INPB",16777215,1,"BSOC:BSY0:1:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:BSY0:3:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:BSY0:3:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:BSY0:3:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:BSY0:3:WARNINGMODE") field(INPB, "BSOC:BSY0:3:GAMMAACT.SEVR") field(HIHI, "1") field(HHSV, "MINOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:BSY0:3:WARNINGMODE",3440,3386,0,1,"BSOC:BSY0:3:WARNINGMODE") #! Field("BSOC:BSY0:3:WARNINGMODE.VAL",16777215,1,"BSOC:BSY0:3:WARNINGMODE.VAL") #! Field("BSOC:BSY0:3:WARNINGMODE.FLNK",16777215,1,"BSOC:BSY0:3:WARNINGMODE.FLNK") #! Link("BSOC:BSY0:3:WARNINGMODE.FLNK","BSOC:BSY0:3:CALCWARNING") #! Record("BSOC:BSY0:3:CALCWARNING",3760,3400,0,0,"BSOC:BSY0:3:CALCWARNING") #! Field("BSOC:BSY0:3:CALCWARNING.INPA",16777215,0,"BSOC:BSY0:3:CALCWARNING.INPA") #! Link("BSOC:BSY0:3:CALCWARNING.INPA","BSOC:BSY0:3:WARNINGMODE.VAL") #! Field("BSOC:BSY0:3:CALCWARNING.INPB",16777215,1,"BSOC:BSY0:3:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:BSY0:4:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:BSY0:4:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:BSY0:4:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:BSY0:4:WARNINGMODE") field(INPB, "BSOC:BSY0:4:GAMMAACT.SEVR") field(HIHI, "1") field(HHSV, "MINOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:BSY0:4:WARNINGMODE",3440,3386,0,1,"BSOC:BSY0:4:WARNINGMODE") #! Field("BSOC:BSY0:4:WARNINGMODE.VAL",16777215,1,"BSOC:BSY0:4:WARNINGMODE.VAL") #! Field("BSOC:BSY0:4:WARNINGMODE.FLNK",16777215,1,"BSOC:BSY0:4:WARNINGMODE.FLNK") #! Link("BSOC:BSY0:4:WARNINGMODE.FLNK","BSOC:BSY0:4:CALCWARNING") #! Record("BSOC:BSY0:4:CALCWARNING",3760,3400,0,0,"BSOC:BSY0:4:CALCWARNING") #! Field("BSOC:BSY0:4:CALCWARNING.INPA",16777215,0,"BSOC:BSY0:4:CALCWARNING.INPA") #! Link("BSOC:BSY0:4:CALCWARNING.INPA","BSOC:BSY0:4:WARNINGMODE.VAL") #! Field("BSOC:BSY0:4:CALCWARNING.INPB",16777215,1,"BSOC:BSY0:4:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:BSY0:5:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(FLNK, "BSOC:BSY0:5:CALCWARNING") field(VAL, "0") field(ASG, "MCC") } # Note: autobypass when autobypass PV is 0 record(calcout, "BSOC:BSY0:5:CALCWARNING") { field(CALC, "(!A)*B*(!C)") field(INPA, "BSOC:BSY0:5:WARNINGMODE") field(INPB, "BSOC:BSY0:5:GAMMAACT.SEVR CPP") field(INPC, "BSOC:BSY0:1:MODE CPP") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:BSY0:5:WARNINGMODE",3440,3386,0,1,"BSOC:BSY0:5:WARNINGMODE") #! Field("BSOC:BSY0:5:WARNINGMODE.VAL",16777215,1,"BSOC:BSY0:5:WARNINGMODE.VAL") #! Field("BSOC:BSY0:5:WARNINGMODE.FLNK",16777215,1,"BSOC:BSY0:5:WARNINGMODE.FLNK") #! Link("BSOC:BSY0:5:WARNINGMODE.FLNK","BSOC:BSY0:5:CALCWARNING") #! Record("BSOC:BSY0:5:CALCWARNING",3760,3414,0,0,"BSOC:BSY0:5:CALCWARNING") #! Field("BSOC:BSY0:5:CALCWARNING.INPA",16777215,0,"BSOC:BSY0:5:CALCWARNING.INPA") #! Link("BSOC:BSY0:5:CALCWARNING.INPA","BSOC:BSY0:5:WARNINGMODE.VAL") #! Field("BSOC:BSY0:5:CALCWARNING.INPB",16777215,1,"BSOC:BSY0:5:CALCWARNING.INPB") #! Field("BSOC:BSY0:5:CALCWARNING.INPC",16777215,1,"BSOC:BSY0:5:CALCWARNING.INPC") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:BSY0:6:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(FLNK, "BSOC:BSY0:6:CALCWARNING") field(ASG, "MCC") field(VAL, "0") } record(calcout, "BSOC:BSY0:6:CALCWARNING") { field(CALC, "(!A)*(B+C)*(!D)") field(INPA, "BSOC:BSY0:6:WARNINGMODE") field(INPB, "BSOC:LTU0:10:NeutronDoseRate.SEVR CPP") field(INPC, "BSOC:LTU0:10:DetectorStatus.SEVR CPP") field(INPD, "BSOC:BSY0:1:MODE CPP") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:BSY0:6:WARNINGMODE",3440,3386,0,1,"BSOC:BSY0:6:WARNINGMODE") #! Field("BSOC:BSY0:6:WARNINGMODE.VAL",16777215,1,"BSOC:BSY0:6:WARNINGMODE.VAL") #! Field("BSOC:BSY0:6:WARNINGMODE.FLNK",16777215,1,"BSOC:BSY0:6:WARNINGMODE.FLNK") #! Link("BSOC:BSY0:6:WARNINGMODE.FLNK","BSOC:BSY0:6:CALCWARNING") #! Record("BSOC:BSY0:6:CALCWARNING",3760,3414,0,0,"BSOC:BSY0:6:CALCWARNING") #! Field("BSOC:BSY0:6:CALCWARNING.INPA",16777215,0,"BSOC:BSY0:6:CALCWARNING.INPA") #! Link("BSOC:BSY0:6:CALCWARNING.INPA","BSOC:BSY0:6:WARNINGMODE.VAL") #! Field("BSOC:BSY0:6:CALCWARNING.INPB",16777215,1,"BSOC:BSY0:6:CALCWARNING.INPB") #! Field("BSOC:BSY0:6:CALCWARNING.INPC",16777215,1,"BSOC:BSY0:6:CALCWARNING.INPC") record(bi, "PLC:BSY0:PP01:SI1A:OFAULT") { field(DESC, "Safety_Ilock_A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/26 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI1A:IFAULT") { field(DESC, "Safety_Ilock_A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/26 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI1A:FAULT") { field(DESC, "Safety_Ilock_A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/26 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI1A:DIAG") { field(DESC, "Safety_Ilock_A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/26 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:RUN") { field(DESC, "Safety_Ilock_A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/26 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:COMM") { field(DESC, "Safety_Ilock_A_Comm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/26 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:OFAULT") { field(DESC, "Safety_Ilock_B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/30 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI1B:IFAULT") { field(DESC, "Safety_Ilock_B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/30 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI1B:FAULT") { field(DESC, "Safety_Ilock_B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/30 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI1B:DIAG") { field(DESC, "Safety_Ilock_B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/30 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:RUN") { field(DESC, "Safety_Ilock_B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/30 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:COMM") { field(DESC, "Safety_Ilock_B_Comm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/30 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC1:SAFETY_MODE") { field(DESC, "Access_Control_Safe_Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/31 T=BYTE B=0") field(ZNAM, "Safe") field(ONAM, "Normal") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:BSY0:1:SIT:DOOR") { field(DESC, "SIT_2_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SIT:GATE") { field(DESC, "SIT_2_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:GATE") { field(DESC, "SIT_1_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:DOOR") { field(DESC, "Sector_30_Egress_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:KEYBANK") { field(DESC, "SIT_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEREXIT") { field(DESC, "SIT_Emer_Exit_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PRESET_1") { field(DESC, "SIT_Preset_1_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/56 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:EMEREXIT") { field(DESC, "S30_Egress_Emer_Exit_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DOOR") { field(DESC, "SARC_2_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SARC:GATE") { field(DESC, "SARC_2_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:GATE") { field(DESC, "SARC_1_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:GATE") { field(DESC, "NIT_1_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:KEYBANK") { field(DESC, "SARC_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEREXIT") { field(DESC, "SARC_Emer_Exit_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/57 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PRESET_2") { field(DESC, "SIT_Preset_2_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PRESET_1") { field(DESC, "SARC_Preset_1_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PRESET_2") { field(DESC, "SARC_Preset_2_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:GATE") { field(DESC, "NARC_1_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEROFF") { field(DESC, "SIT_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEROFF") { field(DESC, "SARC_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEROFF") { field(DESC, "NIT_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/58 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PSVD_PRESET") { field(DESC, "NARC_Psvd_Preset_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=1") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PSVD_PRESET") { field(DESC, "SIT_Psvd_Preset_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=2") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PSVD_PRESET") { field(DESC, "NIT_Psvd_Preset_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=3") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PSVD_PRESET") { field(DESC, "SARC_Psvd_Preset_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=4") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:WEST:EMEROFF") { field(DESC, "West_Upper_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:WEST:EMEROFF") { field(DESC, "West_Bottom_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEROFF") { field(DESC, "NARC_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/64 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PRESET_1") { field(DESC, "NIT_Preset_1_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PRESET_2") { field(DESC, "NIT_Preset_2_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:DOOR") { field(DESC, "NIT_2_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NIT:GATE") { field(DESC, "NIT_2_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PRESET_1") { field(DESC, "NARC_Preset_1_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PRESET_2") { field(DESC, "NARC_Preset_2_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:DOOR") { field(DESC, "NARC_2_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NARC:GATE") { field(DESC, "NARC_2_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/65 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEREXIT") { field(DESC, "NIT_Emer_Exit_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/66 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEREXIT") { field(DESC, "NARC_Emer_Exit_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/66 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:DOOR_LTH") { field(DESC, "SIT_2_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/67 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SIT:GATE_LTH") { field(DESC, "SIT_2_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/67 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:GATE_LTH") { field(DESC, "SIT_1_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/67 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:DOOR_LTH") { field(DESC, "Sector_30_Egress_Dr_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/67 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:KEYBANK_LTH") { field(DESC, "SIT_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/67 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEREXIT_LTH") { field(DESC, "SIT_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/67 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DOOR_LTH") { field(DESC, "SARC_2_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/68 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SARC:GATE_LTH") { field(DESC, "SARC_2_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/68 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:GATE_LTH") { field(DESC, "SARC_1_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/68 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:GATE_LTH") { field(DESC, "NIT_1_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/68 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:KEYBANK_LTH") { field(DESC, "SARC_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/68 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEREXIT_LTH") { field(DESC, "SARC_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:EMEREXIT_LTH") { field(DESC, "S30_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEROFF_LTH") { field(DESC, "SIT_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEROFF_LTH") { field(DESC, "SARC_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEROFF_LTH") { field(DESC, "NIT_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/69 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:WEST:EMEROFF_LTH") { field(DESC, "West_Upper_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:WEST:EMEROFF_LTH") { field(DESC, "West_Bottom_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEROFF_LTH") { field(DESC, "NARC_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:DOOR_LTH") { field(DESC, "NIT_2_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NIT:GATE_LTH") { field(DESC, "NIT_2_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:GATE_LTH") { field(DESC, "NARC_1_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:DOOR_LTH") { field(DESC, "NARC_2_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/70 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NARC:GATE_LTH") { field(DESC, "NARC_2_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/71 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEREXIT_LTH") { field(DESC, "NIT_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/71 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEREXIT_LTH") { field(DESC, "NARC_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/71 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:DOOR_A") { field(DESC, "SIT_2_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SIT:GATE_A") { field(DESC, "SIT_2_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:GATE_A") { field(DESC, "SIT_1_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:DOOR_A") { field(DESC, "Sector_30_Egress_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:KEYBANK_A") { field(DESC, "SIT_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEREXIT_A") { field(DESC, "SIT_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PRESET_1_A") { field(DESC, "SIT_Preset_1_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/74 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:EMEREXIT_A") { field(DESC, "S30_Egress_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DOOR_A") { field(DESC, "SARC_2_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SARC:GATE_A") { field(DESC, "SARC_2_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:GATE_A") { field(DESC, "SARC_1_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:GATE_A") { field(DESC, "NIT_1_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:KEYBANK_A") { field(DESC, "SARC_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEREXIT_A") { field(DESC, "SARC_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/75 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PRESET_2_A") { field(DESC, "SIT_Preset_2_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PRESET_1_A") { field(DESC, "SARC_Preset_1_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PRESET_2_A") { field(DESC, "SARC_Preset_2_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:GATE_A") { field(DESC, "NARC_1_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEROFF_A") { field(DESC, "SIT_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEROFF_A") { field(DESC, "SARC_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEROFF_A") { field(DESC, "NIT_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/76 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PSVD_PRESET_A") { field(DESC, "NARC_Psvd_Preset_State_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=1") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PSVD_PRESET_A") { field(DESC, "SIT_Psvd_Preset_State_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=2") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PSVD_PRESET_A") { field(DESC, "NIT_Psvd_Preset_State_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=3") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PSVD_PRESET_A") { field(DESC, "SARC_Psvd_Preset_State_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=4") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:WEST:EMEROFF_A") { field(DESC, "West_Upper_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:WEST:EMEROFF_A") { field(DESC, "West_Bottom_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEROFF_A") { field(DESC, "NARC_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/82 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PRESET_1_A") { field(DESC, "NIT_Preset_1_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PRESET_2_A") { field(DESC, "NIT_Preset_2_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:DOOR_A") { field(DESC, "NIT_2_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NIT:GATE_A") { field(DESC, "NIT_2_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PRESET_1_A") { field(DESC, "NARC_Preset_1_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PRESET_2_A") { field(DESC, "NARC_Preset_2_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:DOOR_A") { field(DESC, "NARC_2_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NARC:GATE_A") { field(DESC, "NARC_2_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/83 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEREXIT_A") { field(DESC, "NIT_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/84 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEREXIT_A") { field(DESC, "NARC_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/84 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:DOOR_LTH_A") { field(DESC, "SIT_2_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/85 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SIT:GATE_LTH_A") { field(DESC, "SIT_2_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/85 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:GATE_LTH_A") { field(DESC, "SIT_1_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/85 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:DOOR_LTH_A") { field(DESC, "Sector_30_Egress_Dr_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/85 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:KEYBANK_LTH_A") { field(DESC, "SIT_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/85 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEREXIT_LTH_A") { field(DESC, "SIT_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/85 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DOOR_LTH_A") { field(DESC, "SARC_2_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/86 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SARC:GATE_LTH_A") { field(DESC, "SARC_2_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/86 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:GATE_LTH_A") { field(DESC, "SARC_1_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/86 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:GATE_LTH_A") { field(DESC, "NIT_1_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/86 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:KEYBANK_LTH_A") { field(DESC, "SARC_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/86 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEREXIT_LTH_A") { field(DESC, "SARC_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:EMEREXIT_LTH_A") { field(DESC, "S30_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEROFF_LTH_A") { field(DESC, "SIT_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEROFF_LTH_A") { field(DESC, "SARC_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEROFF_LTH_A") { field(DESC, "NIT_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/87 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:WEST:EMEROFF_LTH_A") { field(DESC, "West_Upper_Emer_off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:WEST:EMEROFF_LTH_A") { field(DESC, "West_Bottom_Emer_off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEROFF_LTH_A") { field(DESC, "NARC_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:DOOR_LTH_A") { field(DESC, "NIT_2_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NIT:GATE_LTH_A") { field(DESC, "NIT_2_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:GATE_LTH_A") { field(DESC, "NARC_1_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:DOOR_LTH_A") { field(DESC, "NARC_2_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/88 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NARC:GATE_LTH_A") { field(DESC, "NARC_2_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/89 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEREXIT_LTH_A") { field(DESC, "NIT_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/89 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEREXIT_LTH_A") { field(DESC, "NARC_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/89 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:HEARTBEAT") { field(DESC, "Safety_Intlk_PLC_Hrtbt_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/89 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:COMM_HEARTBEAT") { field(DESC, "Safety_Intlk_Comm_Hrtbt_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/89 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:DOOR_B") { field(DESC, "SIT_2_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SIT:GATE_B") { field(DESC, "SIT_2_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:GATE_B") { field(DESC, "SIT_1_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:DOOR_B") { field(DESC, "Sector_30_Egress_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:KEYBANK_B") { field(DESC, "SIT_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEREXIT_B") { field(DESC, "SIT_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PRESET_1_B") { field(DESC, "SIT_Preset_1_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/92 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:EMEREXIT_B") { field(DESC, "S30_Egress_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DOOR_B") { field(DESC, "SARC_2_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SARC:GATE_B") { field(DESC, "SARC_2_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:GATE_B") { field(DESC, "SARC_1_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:GATE_B") { field(DESC, "NIT_1_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:KEYBANK_B") { field(DESC, "SARC_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEREXIT_B") { field(DESC, "SARC_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/93 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PRESET_2_B") { field(DESC, "SIT_Preset_2_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PRESET_1_B") { field(DESC, "SARC_Preset_1_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PRESET_2_B") { field(DESC, "SARC_Preset_2_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:GATE_B") { field(DESC, "NARC_1_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEROFF_B") { field(DESC, "SIT_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEROFF_B") { field(DESC, "SARC_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEROFF_B") { field(DESC, "NIT_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/94 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PSVD_PRESET_B") { field(DESC, "NARC_Psvd_Preset_State_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=1") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:PSVD_PRESET_B") { field(DESC, "SIT_Psvd_Preset_State_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=2") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PSVD_PRESET_B") { field(DESC, "NIT_Psvd_Preset_State_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=3") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:PSVD_PRESET_B") { field(DESC, "SARC_Psvd_Preset_State_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=4") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:WEST:EMEROFF_B") { field(DESC, "West_Upper_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:WEST:EMEROFF_B") { field(DESC, "West_Bottom_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEROFF_B") { field(DESC, "NARC_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/100 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PRESET_1_B") { field(DESC, "NIT_Preset_1_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:PRESET_2_B") { field(DESC, "NIT_Preset_2_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:DOOR_B") { field(DESC, "NIT_2_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NIT:GATE_B") { field(DESC, "NIT_2_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PRESET_1_B") { field(DESC, "NARC_Preset_1_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:PRESET_2_B") { field(DESC, "NARC_Preset_2_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:DOOR_B") { field(DESC, "NARC_2_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NARC:GATE_B") { field(DESC, "NARC_2_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/101 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEREXIT_B") { field(DESC, "NIT_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/102 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEREXIT_B") { field(DESC, "NARC_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/102 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:DOOR_LTH_B") { field(DESC, "SIT_2_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/103 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SIT:GATE_LTH_B") { field(DESC, "SIT_2_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/103 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:GATE_LTH_B") { field(DESC, "SIT_1_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/103 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:DOOR_LTH_B") { field(DESC, "Sector_30_Egress_Dr_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/103 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:KEYBANK_LTH_B") { field(DESC, "SIT_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/103 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEREXIT_LTH_B") { field(DESC, "SIT_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/103 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DOOR_LTH_B") { field(DESC, "SARC_2_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/104 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:SARC:GATE_LTH_B") { field(DESC, "SARC_2_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/104 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:GATE_LTH_B") { field(DESC, "SARC_1_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/104 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:GATE_LTH_B") { field(DESC, "NIT_1_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/104 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:KEYBANK_LTH_B") { field(DESC, "SARC_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/104 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEREXIT_LTH_B") { field(DESC, "SARC_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:EMEREXIT_LTH_B") { field(DESC, "S30_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:EMEROFF_LTH_B") { field(DESC, "SIT_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:EMEROFF_LTH_B") { field(DESC, "SARC_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEROFF_LTH_B") { field(DESC, "NIT_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/105 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:WEST:EMEROFF_LTH_B") { field(DESC, "West_Upper_Emer_off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:WEST:EMEROFF_LTH_B") { field(DESC, "West_Bottom_Emer_off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEROFF_LTH_B") { field(DESC, "NARC_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:DOOR_LTH_B") { field(DESC, "NIT_2_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NIT:GATE_LTH_B") { field(DESC, "NIT_2_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:GATE_LTH_B") { field(DESC, "NARC_1_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:DOOR_LTH_B") { field(DESC, "NARC_2_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/106 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:NARC:GATE_LTH_B") { field(DESC, "NARC_2_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/107 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NIT:EMEREXIT_LTH_B") { field(DESC, "NIT_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/107 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NARC:EMEREXIT_LTH_B") { field(DESC, "NARC_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/107 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:HEARTBEAT") { field(DESC, "Safety_Intlk_PLC_Hrtbt_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/107 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:COMM_HEARTBEAT") { field(DESC, "Safety_Intlk_Comm_Hrtbt_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/107 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:TEST_MODE") { field(DESC, "Test_Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/134 T=BYTE B=0") field(ZNAM, "Normal") field(ONAM, "Test") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:AC2:BATTERY") { field(DESC, "Access_Ctrl_UPS_Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/134 T=BYTE B=1") field(ZNAM, "Failed") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC2:BATTERY_MODE") { field(DESC, "Access_Ctrl_UPS_Battery_Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/134 T=BYTE B=2") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:BSY0:PP01:AC2:BATTERY_CHARGE") { field(DESC, "Access_Ctrl_UPS_Battery_Charge") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/134 T=BYTE B=3") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:BSY0:PP01:AC2:REM_SWITCH_FAULT") { field(DESC, "Access_Ctrl_Rem_Network_Sw_Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/134 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:MAGLOCK_LCKD") { field(DESC, "SIT_Door_Magnalock_Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/134 T=BYTE B=7") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:MAGLOCK_LCKD") { field(DESC, "SARC_Door_Magnalock_Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/135 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:MAGLOCK_LCKD") { field(DESC, "S30_Egress_Magnalock_Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/135 T=BYTE B=3") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:AV_LIGHT_CONT_1") { field(DESC, "BSY_AV_Light_Cont_1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/135 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:BSY0:1:AV_LIGHT_CONT_2") { field(DESC, "BSY_AV_Light_Cont_2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/135 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:BSY0:1:AUDIO_PLAY") { field(DESC, "A/V_Message_Playing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/135 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:ALL_ZONE_CLEAR") { field(DESC, "All_Zones_Clear_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/136 T=BYTE B=0") field(ZNAM, "NOT_CLEAR") field(ONAM, "CLEAR") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RDM_OK") { field(DESC, "RDM_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/136 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RDM_1") { field(DESC, "BSY_RDM1_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/137 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RDM_2") { field(DESC, "BSY_RDM2_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/137 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RDM_BYP_KEYSWITCH") { field(DESC, "RDM_Bypass_Keyswitch") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/138 T=BYTE B=0") field(ZNAM, "Not_Bypassed") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:BSY0:1:VENTFAN_STS") { field(DESC, "Fan_Contactor") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/138 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:YM_YELLOW") { field(DESC, "Yellow_Light_Realtime") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/139 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:YM_MAGENTA") { field(DESC, "Magenta_Light_Realtime") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/139 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PERM_ACCESS") { field(DESC, "Permitted_Access_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/139 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CTRL_ACCESS") { field(DESC, "Controlled_Access_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/139 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:REST_ACCESS") { field(DESC, "Restricted_Access_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/139 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:NO_ACCESS") { field(DESC, "No_Access_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/139 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:MAGLOCK_ON") { field(DESC, "SIT_2_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/140 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:MAGLOCK_ON") { field(DESC, "SARC2_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/140 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:S30_EGRESS:MAGLOCK_ON") { field(DESC, "S30_Egress_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/140 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:VENT_OK") { field(DESC, "BSY_vent_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/140 T=BYTE B=3") field(ZNAM, "Not_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC1:HEARTBEAT") { field(DESC, "Access_Ctrl_Hrtbt_Source") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/140 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:ALL_DOOR_GATE_CLSD") { field(DESC, "All_Doors_Gates_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/141 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1A:HEARTBEAT_OK") { field(DESC, "Safety_Intlk_ChA_Hrtbt_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/141 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI1B:HEARTBEAT_OK") { field(DESC, "Safety_Intlk_ChB_Hrtbt_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/141 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:YM_BYPASS") { field(DESC, "Magenta_Light_Bypassed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/141 T=BYTE B=5") field(ZNAM, "Bypassed") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EE_BUZ_BYPASS") { field(DESC, "EE_Buzzer_Bypassed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/142 T=BYTE B=4") field(ZNAM, "Bypassed") field(ONAM, "Not_Bypassed") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SIT:DIB_STS") { field(DESC, "SIT_DIB_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/142 T=BYTE B=6") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SARC:DIB_STS") { field(DESC, "SARC_DIB_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/142 T=BYTE B=7") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_1") { field(DESC, "Preset_1_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/143 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_2") { field(DESC, "Preset_2_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/143 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_3") { field(DESC, "Preset_3_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/143 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_4") { field(DESC, "Preset_4_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/143 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_5") { field(DESC, "Preset_5_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/143 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC1:MAIN_SWITCH_FAULT") { field(DESC, "Main_Network_Switch_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/143 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:DOOR") { field(DESC, "Manway_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/230 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:GATE") { field(DESC, "Manway_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/230 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:KEYBANK") { field(DESC, "Manway_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/230 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EQKEYBANK") { field(DESC, "Manway_Equip_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/230 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EMEREXIT") { field(DESC, "Manway_Emer_Exit_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/230 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MCC:KEYBANK") { field(DESC, "MCC_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/230 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:SEARCHRESET") { field(DESC, "Main_Acc_Search_Reset_State") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE") { field(DESC, "Main_Acc_Inner_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQUIP_GATE") { field(DESC, "Main_Acc_Eq_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:BCD_DOOR") { field(DESC, "Main_Acc_Concrete_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:KEYBANK") { field(DESC, "Main_Acc_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQKEYBANK") { field(DESC, "Main_Acc_Equip_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEREXIT") { field(DESC, "Main_Acc_Emer_Exit_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/231 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEROFF") { field(DESC, "Main_Acc_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/232 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEROFF") { field(DESC, "CW2_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/232 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EAST:EMEROFF") { field(DESC, "East_housing_Emergency_Off_1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/238 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:EAST:EMEROFF") { field(DESC, "East_housing_Emergency_Off_2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/238 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEROFF") { field(DESC, "CW4_Emergency_Off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/238 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:DOOR") { field(DESC, "CW2_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/239 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:GATE") { field(DESC, "CW2_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/239 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:DOOR") { field(DESC, "CW4_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/239 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:GATE") { field(DESC, "CW4_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/239 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEREXIT") { field(DESC, "CW2_Emer_Exit_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/240 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEREXIT") { field(DESC, "CW4_Emer_Exit_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/240 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:DOOR_LTH") { field(DESC, "Manway_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/241 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:GATE_LTH") { field(DESC, "Manway_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/241 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:KEYBANK_LTH") { field(DESC, "Manway_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/241 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EQKEYBANK_LTH") { field(DESC, "Manway_Equip_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/241 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EMEREXIT_LTH") { field(DESC, "Manway_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/241 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE_LTH") { field(DESC, "Main_Acc_Inner_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/242 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQUIP_GATE_LTH") { field(DESC, "Main_Acc_Eq_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/242 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:BCD_DOOR_LTH") { field(DESC, "Main_Acc_Concrete_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/242 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:KEYBANK_LTH") { field(DESC, "Main_Acc_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/242 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQKEYBANK_LTH") { field(DESC, "Main_Acc_Equip_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/242 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEREXIT_LTH") { field(DESC, "Main_Acc_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/243 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MCC:KEYBANK_LTH") { field(DESC, "MCC_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/243 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/243 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/243 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEROFF_LTH") { field(DESC, "Main_Acc_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/243 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEROFF_LTH") { field(DESC, "CW2_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/243 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EAST:EMEROFF_LTH") { field(DESC, "East_Emer_Off_1_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/244 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:EAST:EMEROFF_LTH") { field(DESC, "East_Emer_Off_2_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/244 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEROFF_LTH") { field(DESC, "CW4_Emer_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/244 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:DOOR_LTH") { field(DESC, "CW2_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/244 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:GATE_LTH") { field(DESC, "CW2_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/244 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:DOOR_LTH") { field(DESC, "CW4_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/244 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:GATE_LTH") { field(DESC, "CW4_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/245 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEREXIT_LTH") { field(DESC, "CW2_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/245 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEREXIT_LTH") { field(DESC, "CW4_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/245 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:DOOR_A") { field(DESC, "Manway_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/248 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:GATE_A") { field(DESC, "Manway_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/248 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:KEYBANK_A") { field(DESC, "Manway_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/248 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EQKEYBANK_A") { field(DESC, "Manway_Equip_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/248 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EMEREXIT_A") { field(DESC, "Manway_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/248 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MCC:KEYBANK_A") { field(DESC, "MCC_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/248 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:SEARCHRESET_A") { field(DESC, "Main_Acc_Search_Reset_State_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE_A") { field(DESC, "Main_Acc_Inner_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQUIP_GATE_A") { field(DESC, "Main_Acc_Eq_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:BCD_DOOR_A") { field(DESC, "Main_Acc_Concrete_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:KEYBANK_A") { field(DESC, "Main_Acc_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQKEYBANK_A") { field(DESC, "Main_Acc_Equip_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEREXIT_A") { field(DESC, "Main_Acc_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/249 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEROFF_A") { field(DESC, "Main_Acc_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/250 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEROFF_A") { field(DESC, "CW2_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/250 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EAST:EMEROFF_A") { field(DESC, "East_Emer_Off_1_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/256 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:EAST:EMEROFF_A") { field(DESC, "East_Emer_Off_2_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/256 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEROFF_A") { field(DESC, "CW4_Emer_Off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/256 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:DOOR_A") { field(DESC, "CW2_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/257 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:GATE_A") { field(DESC, "CW2_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/257 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:DOOR_A") { field(DESC, "CW4_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/257 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:GATE_A") { field(DESC, "CW4_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/257 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEREXIT_A") { field(DESC, "CW2_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/258 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEREXIT_A") { field(DESC, "CW4_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/258 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:DOOR_LTH_A") { field(DESC, "Manway_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/259 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:GATE_LTH_A") { field(DESC, "Manway_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/259 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:KEYBANK_LTH_A") { field(DESC, "Manway_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/259 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EQKEYBANK_LTH_A") { field(DESC, "Manway_Equip_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/259 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EMEREXIT_LTH_A") { field(DESC, "Manway_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/259 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE_LTH_A") { field(DESC, "Main_Acc_Inner_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/260 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQUIP_GATE_LTH_A") { field(DESC, "Main_Acc_Eq_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/260 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:BCD_DOOR_LTH_A") { field(DESC, "Main_Acc_Concrete_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/260 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:KEYBANK_LTH_A") { field(DESC, "Main_Acc_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/260 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQKEYBANK_LTH_A") { field(DESC, "Main_Acc_Equip_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/260 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEREXIT_LTH_A") { field(DESC, "Main_Acc_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/261 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MCC:KEYBANK_LTH_A") { field(DESC, "MCC_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/261 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/261 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/261 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEROFF_LTH_A") { field(DESC, "Main_Acc_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/261 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEROFF_LTH_A") { field(DESC, "CW2_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/261 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EAST:EMEROFF_LTH_A") { field(DESC, "East_Emer_Off_1_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/262 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:EAST:EMEROFF_LTH_A") { field(DESC, "East_Emer_Off_2_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/262 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEROFF_LTH_A") { field(DESC, "CW4_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/262 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:DOOR_LTH_A") { field(DESC, "CW2_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/262 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:GATE_LTH_A") { field(DESC, "CW2_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/262 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:DOOR_LTH_A") { field(DESC, "CW4_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/262 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:GATE_LTH_A") { field(DESC, "CW4_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/263 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEREXIT_LTH_A") { field(DESC, "CW2_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/263 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEREXIT_LTH_A") { field(DESC, "CW4_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/263 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:HEARTBEAT") { field(DESC, "Safety_Intlk_PLC_Hrtbt_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/263 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:COMM_HEARTBEAT") { field(DESC, "Safety_Intlk_Comm_Hrtbt_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/263 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:DOOR_B") { field(DESC, "Manway_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/266 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:GATE_B") { field(DESC, "Manway_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/266 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:KEYBANK_B") { field(DESC, "Manway_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/266 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EQKEYBANK_B") { field(DESC, "Manway_Equip_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/266 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EMEREXIT_B") { field(DESC, "Manway_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/266 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MCC:KEYBANK_B") { field(DESC, "MCC_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/266 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:SEARCHRESET_B") { field(DESC, "Main_Acc_Search_Reset_State_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE_B") { field(DESC, "Main_Acc_Inner_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQUIP_GATE_B") { field(DESC, "Main_Acc_Eq_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:BCD_DOOR_B") { field(DESC, "Main_Acc_Concrete_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:KEYBANK_B") { field(DESC, "Main_Acc_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQKEYBANK_B") { field(DESC, "Main_Acc_Equip_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEREXIT_B") { field(DESC, "Main_Acc_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/267 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEROFF_B") { field(DESC, "Main_Acc_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/268 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEROFF_B") { field(DESC, "CW2_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/268 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EAST:EMEROFF_B") { field(DESC, "East_Emer_Off_1_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/274 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:EAST:EMEROFF_B") { field(DESC, "East_Emer_Off_2_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/274 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEROFF_B") { field(DESC, "CW4_Emer_Off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/274 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:DOOR_B") { field(DESC, "CW2_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/275 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:GATE_B") { field(DESC, "CW2_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/275 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:DOOR_B") { field(DESC, "CW4_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/275 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:GATE_B") { field(DESC, "CW4_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/275 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEREXIT_B") { field(DESC, "CW2_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/276 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEREXIT_B") { field(DESC, "CW4_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/276 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:DOOR_LTH_B") { field(DESC, "Manway_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/277 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:GATE_LTH_B") { field(DESC, "Manway_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/277 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:KEYBANK_LTH_B") { field(DESC, "Manway_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/277 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EQKEYBANK_LTH_B") { field(DESC, "Manway_Equip_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/277 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:EMEREXIT_LTH_B") { field(DESC, "Manway_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/277 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE_LTH_B") { field(DESC, "Main_Acc_Inner_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/278 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQUIP_GATE_LTH_B") { field(DESC, "Main_Acc_Eq_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/278 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:BCD_DOOR_LTH_B") { field(DESC, "Main_Acc_Concrete_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/278 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:KEYBANK_LTH_B") { field(DESC, "Main_Acc_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/278 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQKEYBANK_LTH_B") { field(DESC, "Main_Acc_Equip_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/278 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEREXIT_LTH_B") { field(DESC, "Main_Acc_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/279 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MCC:KEYBANK_LTH_B") { field(DESC, "MCC_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/279 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/279 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/279 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EMEROFF_LTH_B") { field(DESC, "Main_Acc_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/279 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEROFF_LTH_B") { field(DESC, "CW2_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/279 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:EAST:EMEROFF_LTH_B") { field(DESC, "East_Emer_Off_1_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/280 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:EAST:EMEROFF_LTH_B") { field(DESC, "East_Emer_Off_2_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/280 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEROFF_LTH_B") { field(DESC, "CW4_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/280 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:DOOR_LTH_B") { field(DESC, "CW2_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/280 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:GATE_LTH_B") { field(DESC, "CW2_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/280 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:DOOR_LTH_B") { field(DESC, "CW4_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/280 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:GATE_LTH_B") { field(DESC, "CW4_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/281 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW2:EMEREXIT_LTH_B") { field(DESC, "CW2_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/281 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:CW4:EMEREXIT_LTH_B") { field(DESC, "CW4_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/281 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:HEARTBEAT") { field(DESC, "Safety_Intlk_PLC_Hrtbt_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/281 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:COMM_HEARTBEAT") { field(DESC, "Safety_Intlk_Comm_Hrtbt_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/281 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:OFAULT") { field(DESC, "Safety_Ilock_A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/286 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI2A:IFAULT") { field(DESC, "Safety_Ilock_A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/286 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI2A:FAULT") { field(DESC, "Safety_Ilock_A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/286 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI2A:DIAG") { field(DESC, "Safety_Ilock_A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/286 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:RUN") { field(DESC, "Safety_Ilock_A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/286 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:COMM") { field(DESC, "Safety_Ilock_A_Comm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/286 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:OFAULT") { field(DESC, "Safety_Ilock_B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/290 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI2B:IFAULT") { field(DESC, "Safety_Ilock_B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/290 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI2B:FAULT") { field(DESC, "Safety_Ilock_B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/290 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI2B:DIAG") { field(DESC, "Safety_Ilock_B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/290 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:RUN") { field(DESC, "Safety_Ilock_B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/290 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:COMM") { field(DESC, "Safety_Ilock_B_Comm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/290 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DOOR") { field(DESC, "BTHW_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/344 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:GATE") { field(DESC, "BTHW_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/344 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:BOUND_GATE") { field(DESC, "BTH_Bound_Gate_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/344 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SLIDE_DOOR") { field(DESC, "BTHW_Slide_Door_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/344 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:KEYBANK") { field(DESC, "BTHW_Keybank_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/344 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEREXIT") { field(DESC, "BTHW_Emer_Exit_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/344 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:HATCH") { field(DESC, "BTHW_Ladder_Hatch_Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/345 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SEARCHRESET") { field(DESC, "BSY_Zone_Srch_Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/346 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEROFF") { field(DESC, "BTHW_West_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/346 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:3:EAST:EMEROFF") { field(DESC, "C_line_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/346 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:BTHW:EMEROFF") { field(DESC, "BTHW_East_Emergency_off_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/352 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SSO1") { field(DESC, "SSO1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/354 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_XCHCK_RR_OUT") { field(DESC, "RO_Cross_Check_RR_Out_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/354 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_XCHCK_RR_IN") { field(DESC, "RO_Cross_Check_RR_In_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/354 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_INTACT") { field(DESC, "RO_Zone_Intact_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/354 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_CLEAR") { field(DESC, "RO_Zone_Clear_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/354 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_READY") { field(DESC, "RO_Zone_Rad_Ready_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/354 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_PLAY_AUD") { field(DESC, "RO_Play_Audio_sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DOOR_LTH") { field(DESC, "BTHW_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:GATE_LTH") { field(DESC, "BTHW_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:BOUND_GATE_LTH") { field(DESC, "BTH_Bound_Gate_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SLIDE_DOOR_LTH") { field(DESC, "BTHW_Slide_Door_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:KEYBANK_LTH") { field(DESC, "BTHW_Keybank_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEREXIT_LTH") { field(DESC, "BTHW_Door_Emer_Exit_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/355 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SEARCHRESET") { field(DESC, "BTHW_Srch_Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/356 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:PSVD_PRESET") { field(DESC, "BTHW_Ladder_Shaft_Pres_Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/356 T=BYTE B=1") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:HATCH_LTH") { field(DESC, "BTHW_Ladder_Hatch_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/356 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/357 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/357 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEROFF_LTH") { field(DESC, "BTHW_West_EO_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/357 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:3:EAST:EMEROFF_LTH") { field(DESC, "C_line_Emergency_Off_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/357 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:BTHW:EMEROFF_LTH") { field(DESC, "BTHW_East_EO_Lat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/358 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:INTLKCOM") { field(DESC, "No_Access_Interlocks_Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/359 T=BYTE B=3") field(ZNAM, "Not_complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BEAM_IMM_TT") { field(DESC, "Beam_Imnt_Timer_Timing_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/359 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BEAM_IMM_DN") { field(DESC, "Beam_Imnt_Timer_Complete_Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/359 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DOOR_A") { field(DESC, "BTHW_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/362 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:GATE_A") { field(DESC, "BTHW_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/362 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:BOUND_GATE_A") { field(DESC, "BTH_Bound_Gate_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/362 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SLIDE_DOOR_A") { field(DESC, "BTHW_Slide_Door_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/362 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:KEYBANK_A") { field(DESC, "BTHW_Keybank_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/362 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEREXIT_A") { field(DESC, "BTHW_Emer_Exit_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/362 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:HATCH_A") { field(DESC, "BTHW_Ladder_Hatch_Closed_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/363 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SEARCHRESET_A") { field(DESC, "BSY_Zone_Srch_Reset_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/364 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEROFF_A") { field(DESC, "BTHW_West_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/364 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:3:EAST:EMEROFF_A") { field(DESC, "C_line_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/364 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:BTHW:EMEROFF_A") { field(DESC, "BTHW_East_Emergency_off_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/370 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SSO1_A") { field(DESC, "SSO1_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/372 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_XCHCK_RR_OUT_A") { field(DESC, "RO_Cross_Check_RR_Out_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/372 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_XCHCK_RR_IN_A") { field(DESC, "RO_Cross_Check_RR_In_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/372 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_INTACT_A") { field(DESC, "RO_Zone_Intact_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/372 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_CLEAR_A") { field(DESC, "RO_Zone_Clear_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/372 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_READY_A") { field(DESC, "RO_Zone_Rad_Ready_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/372 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_PLAY_AUD_A") { field(DESC, "RO_Play_Audio_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DOOR_LTH_A") { field(DESC, "BTHW_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:GATE_LTH_A") { field(DESC, "BTHW_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:BOUND_GATE_LTH_A") { field(DESC, "BTH_Bound_Gate_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SLIDE_DOOR_LTH_A") { field(DESC, "BTHW_Slide_Door_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:KEYBANK_LTH_A") { field(DESC, "BTHW_Keybank_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEREXIT_LTH_A") { field(DESC, "BTHW_Emer_Exit_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/373 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SEARCHRESET_A") { field(DESC, "BTHW_Srch_Reset_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/374 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:PSVD_PRESET_A") { field(DESC, "BTHW_Ladder_Shaft_Pres_Preset_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/374 T=BYTE B=1") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:HATCH_LTH_A") { field(DESC, "BTHW_Ladder_Hatch_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/374 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/375 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/375 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEROFF_LTH_A") { field(DESC, "BTHW_West_Emer_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/375 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:3:EAST:EMEROFF_LTH_A") { field(DESC, "C_line_Emergency_Off_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/375 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:BTHW:EMEROFF_LTH_A") { field(DESC, "BTHW_East_EO_Lat_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/376 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:INTLKCOM_A") { field(DESC, "No_Acccess_Interlocks_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/377 T=BYTE B=3") field(ZNAM, "Not_complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BEAM_IMM_TT_A") { field(DESC, "Beam_Imnt_Timer_Timing_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/377 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BEAM_IMM_DN_A") { field(DESC, "Beam_Imnt_Timer_Complete_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/377 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:HEARTBEAT") { field(DESC, "Safety_Intlk_PLC_Hrtbt_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/377 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:COMM_HEARTBEAT") { field(DESC, "Safety_Intlk_Comm_Hrtbt_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/377 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DOOR_B") { field(DESC, "BTHW_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/380 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:GATE_B") { field(DESC, "BTHW_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/380 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:BOUND_GATE_B") { field(DESC, "BTH_Bound_Gate_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/380 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SLIDE_DOOR_B") { field(DESC, "BTHW_Slide_Door_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/380 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:KEYBANK_B") { field(DESC, "BTHW_Keybank_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/380 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEREXIT_B") { field(DESC, "BTHW_Emer_Exit_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/380 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:HATCH_B") { field(DESC, "BTHW_Ladder_Hatch_Closed_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/381 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SEARCHRESET_B") { field(DESC, "BSY_Zone_Srch_Reset_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/382 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEROFF_B") { field(DESC, "BTHW_West_Emer_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/382 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:3:EAST:EMEROFF_B") { field(DESC, "C_line_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/382 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:BTHW:EMEROFF_B") { field(DESC, "BTHW_East_Emergency_off_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/388 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:SSO1_B") { field(DESC, "SSO1_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/390 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_XCHCK_RR_OUT_B") { field(DESC, "RO_Cross_Check_RR_Out_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/390 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_XCHCK_RR_IN_B") { field(DESC, "RO_Cross_Check_RR_In_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/390 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_INTACT_B") { field(DESC, "RO_Zone_Intact_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/390 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_CLEAR_B") { field(DESC, "RO_Zone_Clear_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/390 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_ZN_READY_B") { field(DESC, "RO_Zone_Rad_Ready_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/390 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:RO_PLAY_AUD_B") { field(DESC, "RO_Play_Audio_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DOOR_LTH_B") { field(DESC, "BTHW_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:GATE_LTH_B") { field(DESC, "BTHW_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:BOUND_GATE_LTH_B") { field(DESC, "BTH_Bound_Gate_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SLIDE_DOOR_LTH_B") { field(DESC, "BTHW_Slide_Door_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:KEYBANK_LTH_B") { field(DESC, "BTHW_Keybank_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEREXIT_LTH_B") { field(DESC, "BTHW_Emer_Exit_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/391 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:SEARCHRESET_B") { field(DESC, "BTHW_Srch_Reset_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/392 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:PSVD_PRESET_B") { field(DESC, "BTHW_Ladder_Shaft_Pres_Preset_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/392 T=BYTE B=1") field(ZNAM, "Not_Preserved") field(ONAM, "Preserved") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:HATCH_LTH_B") { field(DESC, "BTHW_Ladder_Hatch_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/392 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:COMM_OK") { field(DESC, "Safety_Intlk_PLC_Comm_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/393 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:SAFELINK_OK") { field(DESC, "Safety_Intlk_PLC_Safelink_OK_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/393 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:EMEROFF_LTH_B") { field(DESC, "BTHW_West_Emer_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/393 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:3:EAST:EMEROFF_LTH_B") { field(DESC, "C_line_Emergency_Off_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/393 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:2:BTHW:EMEROFF_LTH_B") { field(DESC, "BTHW_East_EO_Lat_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/394 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:INTLKCOM_B") { field(DESC, "No_Access_Interlocks_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/395 T=BYTE B=3") field(ZNAM, "Not_complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BEAM_IMM_TT_B") { field(DESC, "Beam_Imnt_Timer_Timing_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/395 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BEAM_IMM_DN_B") { field(DESC, "Beam_Imnt_Timer_Complete_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/395 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:HEARTBEAT") { field(DESC, "Safety_Intlk_PLC_Hrtbt_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/395 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:COMM_HEARTBEAT") { field(DESC, "Safety_Intlk_Comm_Hrtbt_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/395 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:OFAULT") { field(DESC, "Safety_Ilock_A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/400 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI3A:IFAULT") { field(DESC, "Safety_Ilock_A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/400 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI3A:FAULT") { field(DESC, "Safety_Ilock_A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/400 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI3A:DIAG") { field(DESC, "Safety_Ilock_A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/400 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:RUN") { field(DESC, "Safety_Ilock_A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/400 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:COMM") { field(DESC, "Safety_Ilock_A_Comm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/400 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:OFAULT") { field(DESC, "Safety_Ilock_B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/404 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI3B:IFAULT") { field(DESC, "Safety_Ilock_B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/404 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI3B:FAULT") { field(DESC, "Safety_Ilock_B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/404 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:BSY0:PP01:SI3B:DIAG") { field(DESC, "Safety_Ilock_B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/404 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:RUN") { field(DESC, "Safety_Ilock_B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/404 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:COMM") { field(DESC, "Safety_Ilock_B_Comm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/404 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC3:BATTERY") { field(DESC, "Access_Ctrl_UPS_Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/470 T=BYTE B=1") field(ZNAM, "Failed") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC3:BATTERY_MODE") { field(DESC, "Access_Ctrl_UPS_Battery_Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/470 T=BYTE B=2") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:BSY0:PP01:AC3:BATTERY_CHARGE") { field(DESC, "Access_Ctrl_UPS_Battery_Charge") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/470 T=BYTE B=3") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:BSY0:PP01:AC3:REM_SWITCH_FAULT") { field(DESC, "Access_Ctrl_Rem_Network_Sw_Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/470 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:MAGLOCK_LCKD") { field(DESC, "Manway_Dr_Magnalock_Lckd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/470 T=BYTE B=7") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:MAGLOCK_LCKD") { field(DESC, "Main_Acc_Dr_Magnalock_Lckd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/471 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQ_MAGLOCK_LCKD") { field(DESC, "Main_Acc_Equip_Magnalock_Lckd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/471 T=BYTE B=3") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_8") { field(DESC, "Preset_8_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/473 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_10") { field(DESC, "Preset_10_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/473 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MANWAY:MAGLOCK_ON") { field(DESC, "Manway_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/476 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:MAGLOCK_ON") { field(DESC, "Main_Acc_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/476 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:EQ_MAGLOCK_ON") { field(DESC, "Main_Acc_Equip_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/476 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2A:HEARTBEAT_OK") { field(DESC, "Safety_Intlk_ChA_Hrtbt_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/477 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI2B:HEARTBEAT_OK") { field(DESC, "Safety_Intlk_ChB_Hrtbt_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/477 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:IN_GATE_BYP") { field(DESC, "All_Inner_Gate_Intlk_Bypassed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/478 T=BYTE B=5") field(ZNAM, "Not_Bypassed") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:BSY0:1:MANWAY:DIB_STS") { field(DESC, "Manway_DIB_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/478 T=BYTE B=6") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:MAINACC:DIB_STS") { field(DESC, "Main_Acc_DIB_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/478 T=BYTE B=7") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_6") { field(DESC, "Preset_6_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/479 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_7") { field(DESC, "Preset_7_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/479 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_11") { field(DESC, "Preset_11_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/479 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_12") { field(DESC, "Preset_12_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/479 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:AC4:REM_SWITCH_FAULT") { field(DESC, "Access_Ctrl_Rem_Network_Sw_Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/510 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:MAGLOCK_LCKD") { field(DESC, "BTHW_Dr_Magnalock_Lckd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/510 T=BYTE B=7") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:AV_LIGHT_CONT_1") { field(DESC, "BSY_AV_Light_Cont_1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/511 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:BSY0:1:BTHW:AV_LIGHT_CONT_2") { field(DESC, "BSY_AV_Light_Cont_2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/511 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:BSY0:1:BTHW:MAGLOCK_ON") { field(DESC, "BTHW_Maglock_Energized") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/516 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MINOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:VENTFAN_STS") { field(DESC, "Fan_Contactor") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/516 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3A:HEARTBEAT_OK") { field(DESC, "Safety_Intlk_ChA_Hrtbt_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/517 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:BSY0:PP01:SI3B:HEARTBEAT_OK") { field(DESC, "Safety_Intlk_ChB_Hrtbt_Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/517 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:DIB_STS") { field(DESC, "BTHW_DIB_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/518 T=BYTE B=6") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:PRESET_1") { field(DESC, "BTHW_Muon_Preset_1_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/519 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:BTHW:PRESET_2") { field(DESC, "BTHW_Entry_Preset_2_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/519 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:BSY0:1:PRESET_9") { field(DESC, "Preset_9_Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/519 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bo, "PPS:BSY0:1:SIT:DOOR_RELEASE") { field(DESC, "Request_SIT_Door_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SARC:DOOR_RELEASE") { field(DESC, "Request_SARC_Door_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:RESET_INTLK") { field(DESC, "Request_Interlock_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_SEARCHRESET") { field(DESC, "Request_Global_BSY_Search_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SIT:REQ_INT_SEARCH") { field(DESC, "Request_Interrupt_SIT_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SARC:REQ_INT_SEARCH") { field(DESC, "Request_Interrupt_SARC_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:NIT:REQ_INT_SEARCH") { field(DESC, "Request_Interrupt_NIT_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/101 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:AC1:REQ_SUSP_HRTBT") { field(DESC, "Request_Susp_Plc_Hrtbeats") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/102 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:NARC:REQ_INT_SEARCH") { field(DESC, "Request_Interrupt_NARC_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/102 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SIT:REQ_PSVD_PRESET") { field(DESC, "Request_Preserved_Preset_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/102 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SARC:REQ_PSVD_PRESET") { field(DESC, "Request_Preserved_Preset_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/102 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:NIT:REQ_PSVD_PRESET") { field(DESC, "Request_Preserved_Preset_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/102 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:NARC:REQ_PSVD_PRESET") { field(DESC, "Request_Preserved_Preset_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/102 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_PERM_ACCESS") { field(DESC, "Request_Permitted_Access") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_CTRL_ACCESS") { field(DESC, "Request_Controlled_Access") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_REST_ACCESS") { field(DESC, "Request_Restricted_Access") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_NO_ACCESS") { field(DESC, "Request_No_Access") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_LIGHTS_ON") { field(DESC, "Request_Housing_Lights_On") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_LIGHTS_OFF") { field(DESC, "Request_Housing_Lights_Off") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SIT:KEYBANK_RELEASE") { field(DESC, "Request_Prsn_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/105 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:SARC:KEYBANK_RELEASE") { field(DESC, "Request_Prsn_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/106 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_VENTFAN_ON") { field(DESC, "Request_BSY_Ventilation_On") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_VENTFAN_OFF") { field(DESC, "Request_BSY_Ventilation_OFF") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:REQ_VENTFAN_ON") { field(DESC, "Request_BTHW_Ventilation_On") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:REQ_VENTFAN_OFF") { field(DESC, "Request_BTHW_Ventilation_OFF") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_EE_BUZ_BYPASS") { field(DESC, "Request_Bypass_EE_Buzzer") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:REQ_EE_BUZ_RESTORE") { field(DESC, "Restore_EE_Buzzer") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:RESET_SEARCHTIMER") { field(DESC, "Clear_Search_Timer") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:RESET_SEARCHTIMER") { field(DESC, "Clear_Search_Timer") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/108 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:SI1A:RESET_FAULT_CNT") { field(DESC, "Safety_Intlk_CHA_Reset_Flt_Cnt") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/109 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:SI1B:RESET_FAULT_CNT") { field(DESC, "Safety_Intlk_CHB_Reset_Flt_Cnt") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/109 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MANWAY:DOOR_RELEASE") { field(DESC, "Manway_Door_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/112 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:DOOR_RELEASE") { field(DESC, "Main_Acc_Door_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/112 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:REQ_INT_SEARCH") { field(DESC, "Request_Interrupt_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/112 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:REQ_SEARCHRESET") { field(DESC, "Request_Mainacc_Search_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/112 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MANWAY:KEYBANK_RELEASE") { field(DESC, "Request_Prsn_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/116 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MANWAY:EQKEYBANK_RELEASE") { field(DESC, "Request_Eqpm_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/116 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:KEYBANK_RELEASE") { field(DESC, "Request_Prsn_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/116 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:EQKEYBANK_RELEASE") { field(DESC, "Request_Eqpm_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/116 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:SI2A:RESET_FAULT_CNT") { field(DESC, "Safety_Intlk_CHA_Reset_Flt_Cnt") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/119 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:SI2B:RESET_FAULT_CNT") { field(DESC, "Safety_Intlk_CHB_Reset_Flt_Cnt") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/119 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MCC:KEYBANK_RELEASE") { field(DESC, "Request_Prsn_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/119 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:EQUIP_GATE_UNLOCK") { field(DESC, "Request_Equip_Gate_Unlocked") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/119 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:MAINACC:EQUIP_GATE_LOCK") { field(DESC, "Request_Equip_Gate_Locked") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/119 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:DOOR_RELEASE") { field(DESC, "BTHW_Door_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/120 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:REQ_INT_SEARCH") { field(DESC, "Request_Interrupt_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/120 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:REQ_SEARCHRESET") { field(DESC, "Request_BTHW_Search_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/120 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:2:BTHW:REQ_INT_SEARCH") { field(DESC, "Request_Ladder_Interrupt_Search") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/122 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:REQ_PSVD_PRESET") { field(DESC, "Req_Ladder_Pres_Preset_Reset") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/122 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PPS:BSY0:1:BTHW:KEYBANK_RELEASE") { field(DESC, "Request_Prsn_Keybank_Release") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/125 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:SI3A:RESET_FAULT_CNT") { field(DESC, "Safety_Intlk_CHA_Reset_Flt_Cnt") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/127 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(bo, "PLC:BSY0:PP01:SI3B:RESET_FAULT_CNT") { field(DESC, "Safety_Intlk_CHB_Reset_Flt_Cnt") field(DTYP, "S7plc") field(OUT, "@PPS_BSY0_PLC/127 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "MCC") info(autosaveFields, "VAL") } record(longin, "PLC:BSY0:PP01:AC1:SAFETY_SIG") { field(DESC, "Access_Ctrl_Safety_Signature") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/20 T=DWORD") } record(longin, "PLC:BSY0:PP01:SI1A:CHECKSUM") { field(DESC, "Safety_Ilock_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/24 T=WORD") } record(longin, "PLC:BSY0:PP01:SI1B:CHECKSUM") { field(DESC, "Safety_Ilock_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/28 T=WORD") } record(longin, "PLC:BSY0:PP01:AC1:COMPILE_DT_YR") { field(DESC, "Acc_Ctrl_Compile_Year") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/32 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:COMPILE_DT_MON") { field(DESC, "Acc_Ctrl_Compile_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/33 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:COMPILE_DT_DAY") { field(DESC, "Acc_Ctrl_Compile_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/34 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:COMPILE_DT_HR") { field(DESC, "Acc_Ctrl_Compile_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/35 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:COMPILE_DT_MIN") { field(DESC, "Acc_Ctrl_Compile_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/36 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:COMPILE_DT_SEC") { field(DESC, "Acc_Ctrl_Compile_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/37 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:OB100_DT_YR") { field(DESC, "Acc_Ctrl_Warm_Restart_Year") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/38 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:OB100_DT_MON") { field(DESC, "Acc_Ctrl_Warm_Restart_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/39 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:OB100_DT_DAY") { field(DESC, "Acc_Ctrl_Warm_Restart_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/40 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:OB100_DT_HR") { field(DESC, "Acc_Ctrl_Warm_Restart_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/41 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:OB100_DT_MIN") { field(DESC, "Acc_Ctrl_Warm_Restart_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/42 T=BYTE") } record(longin, "PLC:BSY0:PP01:AC1:OB100_DT_SEC") { field(DESC, "Acc_Ctrl_Warm_Restart_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/43 T=BYTE") } record(longin, "PLC:BSY0:PP01:SI1A:COMM_FAULT_CNT") { field(DESC, "Safety_Ilock_A_Comm_Flt_Cnt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/44 T=WORD") } record(longin, "PLC:BSY0:PP01:SI1B:COMM_FAULT_CNT") { field(DESC, "Safety_Ilock_B_Comm_Flt_Cnt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/46 T=WORD") } record(longin, "PPS:BSY0:1:SEARCHTIMER_MIN") { field(DESC, "Search_Timer_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/144 T=WORD") } record(longin, "PPS:BSY0:1:SEARCHTIMER_SEC") { field(DESC, "Search_Timer_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/145 T=WORD") } record(longin, "PPS:BSY0:1:BEAM_IMMINENT") { field(DESC, "Beam_Imminent_Timer") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/146 T=BYTE") } record(longin, "PLC:BSY0:PP01:SI2A:CHECKSUM") { field(DESC, "Safety_Ilock_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/284 T=WORD") } record(longin, "PLC:BSY0:PP01:SI2B:CHECKSUM") { field(DESC, "Safety_Ilock_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/288 T=WORD") } record(longin, "PLC:BSY0:PP01:SI3A:CHECKSUM") { field(DESC, "Safety_Ilock_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/398 T=WORD") } record(longin, "PLC:BSY0:PP01:SI3B:CHECKSUM") { field(DESC, "Safety_Ilock_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/402 T=WORD") } record(longin, "PLC:BSY0:PP01:SI2A:COMM_FAULT_CNT") { field(DESC, "Safety_Ilock_A_Comm_Flt_Cnt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/226 T=WORD") } record(longin, "PLC:BSY0:PP01:SI2B:COMM_FAULT_CNT") { field(DESC, "Safety_Ilock_B_Comm_Flt_Cnt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/228 T=WORD") } record(longin, "PLC:BSY0:PP01:SI3A:COMM_FAULT_CNT") { field(DESC, "Safety_Ilock_A_Comm_Flt_Cnt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/340 T=WORD") } record(longin, "PLC:BSY0:PP01:SI3B:COMM_FAULT_CNT") { field(DESC, "Safety_Ilock_B_Comm_Flt_Cnt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PPS_BSY0_PLC/342 T=WORD") } record(asyn,"SIOC:BSY0:PP01:ASYNDRIVER") { field(DTYP,"asynRecordDevice") field(PORT,"PPS_BSY0_PLC") field(ADDR,"0") field(OMAX,"0") field(IMAX,"0") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi7") { field(DESC, "Port BTM_RDA bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BTM:BSY0:1:HARDWARE_ENABLEA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:HARDWARE_ENABLEA_calc") { field(INPA, "PLC:BSY0:PP03:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:HARDWARE_ENABLEA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:HARDWARE_ENABLEA") { field(DESC, "BTM-Hardware_Enable_A") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb7",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb7") #! Field("PLC:BSY0:PP03:BTM_RDAb7.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb7.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb7.FLNK","BTM:BSY0:1:HARDWARE_ENABLEA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb7.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb7.VAL") #! Record("BTM:BSY0:1:HARDWARE_ENABLEA_calc",260,18,0,1,"BTM:BSY0:1:HARDWARE_ENABLEA_calc") #! Field("BTM:BSY0:1:HARDWARE_ENABLEA_calc.INPA",16777215,0,"BTM:BSY0:1:HARDWARE_ENABLEA_calc.INPA") #! Link("BTM:BSY0:1:HARDWARE_ENABLEA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb7.VAL") #! Field("BTM:BSY0:1:HARDWARE_ENABLEA_calc.INPB",16777215,1,"BTM:BSY0:1:HARDWARE_ENABLEA_calc.INPB") #! Field("BTM:BSY0:1:HARDWARE_ENABLEA_calc.OUT",16777215,1,"BTM:BSY0:1:HARDWARE_ENABLEA_calc.OUT") #! Link("BTM:BSY0:1:HARDWARE_ENABLEA_calc.OUT","BTM:BSY0:1:HARDWARE_ENABLEA.VAL") #! Record("BTM:BSY0:1:HARDWARE_ENABLEA",500,20,0,0,"BTM:BSY0:1:HARDWARE_ENABLEA") #! Field("BTM:BSY0:1:HARDWARE_ENABLEA.VAL",16777215,1,"BTM:BSY0:1:HARDWARE_ENABLEA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi6") { field(DESC, "Port BTM_RDA bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 6, 1, 1)") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(FLNK, "BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc") { field(INPA, "PLC:BSY0:PP03:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:HARDWIRE_INTLK_RESETA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:HARDWIRE_INTLK_RESETA") { field(DESC, "BTM-HW_Intlk_Reset_A") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb6",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb6") #! Field("PLC:BSY0:PP03:BTM_RDAb6.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb6.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb6.FLNK","BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb6.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb6.VAL") #! Record("BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc",260,18,0,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.INPA",16777215,0,"BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.INPA") #! Link("BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb6.VAL") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.INPB",16777215,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.INPB") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.OUT",16777215,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.OUT") #! Link("BTM:BSY0:1:HARDWIRE_INTLK_RESETA_calc.OUT","BTM:BSY0:1:HARDWIRE_INTLK_RESETA.VAL") #! Record("BTM:BSY0:1:HARDWIRE_INTLK_RESETA",500,20,0,0,"BTM:BSY0:1:HARDWIRE_INTLK_RESETA") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETA.VAL",16777215,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi5") { field(DESC, "Port BTM_RDA bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:HEARTBEAT_INA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:HEARTBEAT_INA_calc") { field(INPA, "PLC:BSY0:PP03:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:HEARTBEAT_INA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:HEARTBEAT_INA") { field(DESC, "BTM-RT_Heartbeat_In_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb5",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb5") #! Field("PLC:BSY0:PP03:BTM_RDAb5.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb5.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb5.FLNK","BTM:BSY0:1:HEARTBEAT_INA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb5.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb5.VAL") #! Record("BTM:BSY0:1:HEARTBEAT_INA_calc",260,18,0,1,"BTM:BSY0:1:HEARTBEAT_INA_calc") #! Field("BTM:BSY0:1:HEARTBEAT_INA_calc.INPA",16777215,0,"BTM:BSY0:1:HEARTBEAT_INA_calc.INPA") #! Link("BTM:BSY0:1:HEARTBEAT_INA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb5.VAL") #! Field("BTM:BSY0:1:HEARTBEAT_INA_calc.INPB",16777215,1,"BTM:BSY0:1:HEARTBEAT_INA_calc.INPB") #! Field("BTM:BSY0:1:HEARTBEAT_INA_calc.OUT",16777215,1,"BTM:BSY0:1:HEARTBEAT_INA_calc.OUT") #! Link("BTM:BSY0:1:HEARTBEAT_INA_calc.OUT","BTM:BSY0:1:HEARTBEAT_INA.VAL") #! Record("BTM:BSY0:1:HEARTBEAT_INA",500,20,0,0,"BTM:BSY0:1:HEARTBEAT_INA") #! Field("BTM:BSY0:1:HEARTBEAT_INA.VAL",16777215,1,"BTM:BSY0:1:HEARTBEAT_INA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi3") { field(DESC, "Port BTM_RDA bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 3, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYH:858:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi3 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:PPSTRIPA") { field(DESC, "BTM-RT_DM60_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb3",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb3") #! Field("PLC:BSY0:PP03:BTM_RDAb3.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb3.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb3.FLNK","BTM:BSYH:858:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb3.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb3.VAL") #! Record("BTM:BSYH:858:PPSTRIPA_calc",260,18,0,1,"BTM:BSYH:858:PPSTRIPA_calc") #! Field("BTM:BSYH:858:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYH:858:PPSTRIPA_calc.INPA") #! Link("BTM:BSYH:858:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb3.VAL") #! Field("BTM:BSYH:858:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYH:858:PPSTRIPA_calc.INPB") #! Field("BTM:BSYH:858:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYH:858:PPSTRIPA_calc.OUT") #! Link("BTM:BSYH:858:PPSTRIPA_calc.OUT","BTM:BSYH:858:PPSTRIPA.VAL") #! Record("BTM:BSYH:858:PPSTRIPA",500,20,0,0,"BTM:BSYH:858:PPSTRIPA") #! Field("BTM:BSYH:858:PPSTRIPA.VAL",16777215,1,"BTM:BSYH:858:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi2") { field(DESC, "Port BTM_RDA bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:2:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:2:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:2:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:2:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb2",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb2") #! Field("PLC:BSY0:PP03:BTM_RDAb2.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb2.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb2.FLNK","BTM:BSY0:2:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb2.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb2.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:2:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:2:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:2:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:2:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb2.VAL") #! Field("BTM:BSY0:2:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:2:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:2:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:2:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:2:SPARE:PPSTRIPA") #! Field("BTM:BSY0:2:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi1") { field(DESC, "Port BTM_RDA bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:1240:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1240:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1240:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1240:PPSTRIPA") { field(DESC, "BTM-RT_DM12_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb1",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb1") #! Field("PLC:BSY0:PP03:BTM_RDAb1.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb1.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb1.FLNK","BTM:BSYA:1240:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb1.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb1.VAL") #! Record("BTM:BSYA:1240:PPSTRIPA_calc",260,18,0,1,"BTM:BSYA:1240:PPSTRIPA_calc") #! Field("BTM:BSYA:1240:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYA:1240:PPSTRIPA_calc.INPA") #! Link("BTM:BSYA:1240:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb1.VAL") #! Field("BTM:BSYA:1240:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYA:1240:PPSTRIPA_calc.INPB") #! Field("BTM:BSYA:1240:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYA:1240:PPSTRIPA_calc.OUT") #! Link("BTM:BSYA:1240:PPSTRIPA_calc.OUT","BTM:BSYA:1240:PPSTRIPA.VAL") #! Record("BTM:BSYA:1240:PPSTRIPA",500,20,0,0,"BTM:BSYA:1240:PPSTRIPA") #! Field("BTM:BSYA:1240:PPSTRIPA.VAL",16777215,1,"BTM:BSYA:1240:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi0") { field(DESC, "Port BTM_RDA bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 0, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:1490:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1490:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1490:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1490:PPSTRIPA") { field(DESC, "BTM-RT_DM14_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb0",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb0") #! Field("PLC:BSY0:PP03:BTM_RDAb0.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb0.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb0.FLNK","BTM:BSYA:1490:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb0.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb0.VAL") #! Record("BTM:BSYA:1490:PPSTRIPA_calc",260,18,0,1,"BTM:BSYA:1490:PPSTRIPA_calc") #! Field("BTM:BSYA:1490:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYA:1490:PPSTRIPA_calc.INPA") #! Link("BTM:BSYA:1490:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb0.VAL") #! Field("BTM:BSYA:1490:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYA:1490:PPSTRIPA_calc.INPB") #! Field("BTM:BSYA:1490:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYA:1490:PPSTRIPA_calc.OUT") #! Link("BTM:BSYA:1490:PPSTRIPA_calc.OUT","BTM:BSYA:1490:PPSTRIPA.VAL") #! Record("BTM:BSYA:1490:PPSTRIPA",500,20,0,0,"BTM:BSYA:1490:PPSTRIPA") #! Field("BTM:BSYA:1490:PPSTRIPA.VAL",16777215,1,"BTM:BSYA:1490:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi15") { field(DESC, "Port BTM_RDA bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:2275:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2275:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2275:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2275:PPSTRIPA") { field(DESC, "BTM-RT_DM22_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb15",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb15") #! Field("PLC:BSY0:PP03:BTM_RDAb15.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb15.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb15.FLNK","BTM:BSYA:2275:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb15.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb15.VAL") #! Record("BTM:BSYA:2275:PPSTRIPA_calc",260,18,0,1,"BTM:BSYA:2275:PPSTRIPA_calc") #! Field("BTM:BSYA:2275:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYA:2275:PPSTRIPA_calc.INPA") #! Link("BTM:BSYA:2275:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb15.VAL") #! Field("BTM:BSYA:2275:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYA:2275:PPSTRIPA_calc.INPB") #! Field("BTM:BSYA:2275:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYA:2275:PPSTRIPA_calc.OUT") #! Link("BTM:BSYA:2275:PPSTRIPA_calc.OUT","BTM:BSYA:2275:PPSTRIPA.VAL") #! Record("BTM:BSYA:2275:PPSTRIPA",500,20,0,0,"BTM:BSYA:2275:PPSTRIPA") #! Field("BTM:BSYA:2275:PPSTRIPA.VAL",16777215,1,"BTM:BSYA:2275:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi14") { field(DESC, "Port BTM_RDA bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:2930:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2930:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2930:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2930:PPSTRIPA") { field(DESC, "BTM-RT_DM29_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb14",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb14") #! Field("PLC:BSY0:PP03:BTM_RDAb14.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb14.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb14.FLNK","BTM:BSYA:2930:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb14.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb14.VAL") #! Record("BTM:BSYA:2930:PPSTRIPA_calc",260,18,0,1,"BTM:BSYA:2930:PPSTRIPA_calc") #! Field("BTM:BSYA:2930:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYA:2930:PPSTRIPA_calc.INPA") #! Link("BTM:BSYA:2930:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb14.VAL") #! Field("BTM:BSYA:2930:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYA:2930:PPSTRIPA_calc.INPB") #! Field("BTM:BSYA:2930:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYA:2930:PPSTRIPA_calc.OUT") #! Link("BTM:BSYA:2930:PPSTRIPA_calc.OUT","BTM:BSYA:2930:PPSTRIPA.VAL") #! Record("BTM:BSYA:2930:PPSTRIPA",500,20,0,0,"BTM:BSYA:2930:PPSTRIPA") #! Field("BTM:BSYA:2930:PPSTRIPA.VAL",16777215,1,"BTM:BSYA:2930:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi13") { field(DESC, "Port BTM_RDA bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 13, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYS:889:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:889:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:889:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:889:PPSTRIPA") { field(DESC, "BTM-RT_ST34A_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb13",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb13") #! Field("PLC:BSY0:PP03:BTM_RDAb13.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb13.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb13.FLNK","BTM:BSYS:889:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb13.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb13.VAL") #! Record("BTM:BSYS:889:PPSTRIPA_calc",260,18,0,1,"BTM:BSYS:889:PPSTRIPA_calc") #! Field("BTM:BSYS:889:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYS:889:PPSTRIPA_calc.INPA") #! Link("BTM:BSYS:889:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb13.VAL") #! Field("BTM:BSYS:889:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYS:889:PPSTRIPA_calc.INPB") #! Field("BTM:BSYS:889:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYS:889:PPSTRIPA_calc.OUT") #! Link("BTM:BSYS:889:PPSTRIPA_calc.OUT","BTM:BSYS:889:PPSTRIPA.VAL") #! Record("BTM:BSYS:889:PPSTRIPA",500,20,0,0,"BTM:BSYS:889:PPSTRIPA") #! Field("BTM:BSYS:889:PPSTRIPA.VAL",16777215,1,"BTM:BSYS:889:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi12") { field(DESC, "Port BTM_RDA bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYS:898:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:898:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:898:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:898:PPSTRIPA") { field(DESC, "BTM-RT_ST34B_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb12",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb12") #! Field("PLC:BSY0:PP03:BTM_RDAb12.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb12.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb12.FLNK","BTM:BSYS:898:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb12.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb12.VAL") #! Record("BTM:BSYS:898:PPSTRIPA_calc",260,18,0,1,"BTM:BSYS:898:PPSTRIPA_calc") #! Field("BTM:BSYS:898:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSYS:898:PPSTRIPA_calc.INPA") #! Link("BTM:BSYS:898:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb12.VAL") #! Field("BTM:BSYS:898:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSYS:898:PPSTRIPA_calc.INPB") #! Field("BTM:BSYS:898:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSYS:898:PPSTRIPA_calc.OUT") #! Link("BTM:BSYS:898:PPSTRIPA_calc.OUT","BTM:BSYS:898:PPSTRIPA.VAL") #! Record("BTM:BSYS:898:PPSTRIPA",500,20,0,0,"BTM:BSYS:898:PPSTRIPA") #! Field("BTM:BSYS:898:PPSTRIPA.VAL",16777215,1,"BTM:BSYS:898:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi11") { field(DESC, "Port BTM_RDA bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:CLTS:585:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:CLTS:585:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi11 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:CLTS:585:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:CLTS:585:PPSTRIPA") { field(DESC, "BTM-RT_STCLTS_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb11",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb11") #! Field("PLC:BSY0:PP03:BTM_RDAb11.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb11.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb11.FLNK","BTM:CLTS:585:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb11.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb11.VAL") #! Record("BTM:CLTS:585:PPSTRIPA_calc",260,18,0,1,"BTM:CLTS:585:PPSTRIPA_calc") #! Field("BTM:CLTS:585:PPSTRIPA_calc.INPA",16777215,0,"BTM:CLTS:585:PPSTRIPA_calc.INPA") #! Link("BTM:CLTS:585:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb11.VAL") #! Field("BTM:CLTS:585:PPSTRIPA_calc.INPB",16777215,1,"BTM:CLTS:585:PPSTRIPA_calc.INPB") #! Field("BTM:CLTS:585:PPSTRIPA_calc.OUT",16777215,1,"BTM:CLTS:585:PPSTRIPA_calc.OUT") #! Link("BTM:CLTS:585:PPSTRIPA_calc.OUT","BTM:CLTS:585:PPSTRIPA.VAL") #! Record("BTM:CLTS:585:PPSTRIPA",500,20,0,0,"BTM:CLTS:585:PPSTRIPA") #! Field("BTM:CLTS:585:PPSTRIPA.VAL",16777215,1,"BTM:CLTS:585:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi10") { field(DESC, "Port BTM_RDA bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 10, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:10:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:10:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:10:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:10:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb10",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb10") #! Field("PLC:BSY0:PP03:BTM_RDAb10.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb10.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb10.FLNK","BTM:BSY0:10:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb10.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb10.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:10:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:10:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:10:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:10:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb10.VAL") #! Field("BTM:BSY0:10:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:10:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:10:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:10:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:10:SPARE:PPSTRIPA") #! Field("BTM:BSY0:10:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi9") { field(DESC, "Port BTM_RDA bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:11:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:11:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:11:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:11:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb9",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb9") #! Field("PLC:BSY0:PP03:BTM_RDAb9.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb9.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb9.FLNK","BTM:BSY0:11:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb9.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb9.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:11:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:11:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:11:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:11:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb9.VAL") #! Field("BTM:BSY0:11:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:11:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:11:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:11:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:11:SPARE:PPSTRIPA") #! Field("BTM:BSY0:11:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi8") { field(DESC, "Port BTM_RDA bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 8, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:12:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:12:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:12:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:12:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb8",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb8") #! Field("PLC:BSY0:PP03:BTM_RDAb8.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb8.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb8.FLNK","BTM:BSY0:12:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb8.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb8.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:12:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:12:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:12:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:12:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb8.VAL") #! Field("BTM:BSY0:12:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:12:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:12:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:12:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:12:SPARE:PPSTRIPA") #! Field("BTM:BSY0:12:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi23") { field(DESC, "Port BTM_RDA bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:13:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:13:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:13:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:13:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb23",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb23") #! Field("PLC:BSY0:PP03:BTM_RDAb23.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb23.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb23.FLNK","BTM:BSY0:13:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb23.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb23.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:13:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:13:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:13:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:13:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb23.VAL") #! Field("BTM:BSY0:13:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:13:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:13:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:13:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:13:SPARE:PPSTRIPA") #! Field("BTM:BSY0:13:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi22") { field(DESC, "Port BTM_RDA bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 22, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:14:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:14:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:14:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:14:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb22",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb22") #! Field("PLC:BSY0:PP03:BTM_RDAb22.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb22.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb22.FLNK","BTM:BSY0:14:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb22.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb22.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:14:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:14:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:14:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:14:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb22.VAL") #! Field("BTM:BSY0:14:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:14:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:14:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:14:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:14:SPARE:PPSTRIPA") #! Field("BTM:BSY0:14:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi21") { field(DESC, "Port BTM_RDA bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:15:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:15:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:15:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:15:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb21",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb21") #! Field("PLC:BSY0:PP03:BTM_RDAb21.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb21.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb21.FLNK","BTM:BSY0:15:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb21.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb21.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:15:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:15:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:15:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:15:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb21.VAL") #! Field("BTM:BSY0:15:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:15:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:15:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:15:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:15:SPARE:PPSTRIPA") #! Field("BTM:BSY0:15:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi20") { field(DESC, "Port BTM_RDA bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:16:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:16:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:16:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:16:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb20",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb20") #! Field("PLC:BSY0:PP03:BTM_RDAb20.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb20.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb20.FLNK","BTM:BSY0:16:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb20.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb20.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:16:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:16:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:16:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:16:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb20.VAL") #! Field("BTM:BSY0:16:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:16:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:16:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:16:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:16:SPARE:PPSTRIPA") #! Field("BTM:BSY0:16:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi94") { field(DESC, "Port BTM_RDA bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 94, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:17:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:17:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi94 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:17:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:17:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb94",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb94") #! Field("PLC:BSY0:PP03:BTM_RDAb94.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb94.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb94.FLNK","BTM:BSY0:17:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb94.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb94.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:17:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:17:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:17:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:17:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb94.VAL") #! Field("BTM:BSY0:17:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:17:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:17:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:17:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:17:SPARE:PPSTRIPA") #! Field("BTM:BSY0:17:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi93") { field(DESC, "Port BTM_RDA bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:18:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:18:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi93 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:18:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:18:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb93",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb93") #! Field("PLC:BSY0:PP03:BTM_RDAb93.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb93.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb93.FLNK","BTM:BSY0:18:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb93.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb93.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:18:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:18:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:18:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:18:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb93.VAL") #! Field("BTM:BSY0:18:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:18:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:18:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:18:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:18:SPARE:PPSTRIPA") #! Field("BTM:BSY0:18:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi92") { field(DESC, "Port BTM_RDA bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:19:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:19:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi92 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:19:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:19:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb92",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb92") #! Field("PLC:BSY0:PP03:BTM_RDAb92.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb92.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb92.FLNK","BTM:BSY0:19:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb92.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb92.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:19:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:19:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:19:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:19:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb92.VAL") #! Field("BTM:BSY0:19:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:19:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:19:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:19:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:19:SPARE:PPSTRIPA") #! Field("BTM:BSY0:19:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi91") { field(DESC, "Port BTM_RDA bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:20:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:20:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi91 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:20:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:20:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb91",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb91") #! Field("PLC:BSY0:PP03:BTM_RDAb91.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb91.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb91.FLNK","BTM:BSY0:20:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb91.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb91.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:20:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:20:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:20:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:20:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb91.VAL") #! Field("BTM:BSY0:20:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:20:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:20:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:20:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:20:SPARE:PPSTRIPA") #! Field("BTM:BSY0:20:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi90") { field(DESC, "Port BTM_RDA bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:21:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:21:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:21:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:21:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb90",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb90") #! Field("PLC:BSY0:PP03:BTM_RDAb90.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb90.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb90.FLNK","BTM:BSY0:21:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb90.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb90.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:21:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:21:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:21:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:21:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb90.VAL") #! Field("BTM:BSY0:21:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:21:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:21:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:21:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:21:SPARE:PPSTRIPA") #! Field("BTM:BSY0:21:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi89") { field(DESC, "Port BTM_RDA bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:22:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:22:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:22:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:22:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb89",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb89") #! Field("PLC:BSY0:PP03:BTM_RDAb89.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb89.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb89.FLNK","BTM:BSY0:22:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb89.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb89.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:22:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:22:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:22:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:22:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb89.VAL") #! Field("BTM:BSY0:22:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:22:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:22:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:22:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:22:SPARE:PPSTRIPA") #! Field("BTM:BSY0:22:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi88") { field(DESC, "Port BTM_RDA bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:23:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:23:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:23:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:23:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb88",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb88") #! Field("PLC:BSY0:PP03:BTM_RDAb88.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb88.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb88.FLNK","BTM:BSY0:23:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb88.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb88.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:23:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:23:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:23:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:23:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb88.VAL") #! Field("BTM:BSY0:23:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:23:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:23:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:23:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:23:SPARE:PPSTRIPA") #! Field("BTM:BSY0:23:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi103") { field(DESC, "Port BTM_RDA bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:24:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:24:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:24:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:24:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb103",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb103") #! Field("PLC:BSY0:PP03:BTM_RDAb103.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb103.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb103.FLNK","BTM:BSY0:24:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb103.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb103.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:24:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:24:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:24:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:24:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb103.VAL") #! Field("BTM:BSY0:24:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:24:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:24:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:24:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:24:SPARE:PPSTRIPA") #! Field("BTM:BSY0:24:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi102") { field(DESC, "Port BTM_RDA bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:25:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:25:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:25:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:25:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb102",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb102") #! Field("PLC:BSY0:PP03:BTM_RDAb102.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb102.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb102.FLNK","BTM:BSY0:25:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb102.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb102.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:25:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:25:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:25:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:25:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb102.VAL") #! Field("BTM:BSY0:25:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:25:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:25:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:25:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:25:SPARE:PPSTRIPA") #! Field("BTM:BSY0:25:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi101") { field(DESC, "Port BTM_RDA bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:26:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:26:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:26:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:26:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb101",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb101") #! Field("PLC:BSY0:PP03:BTM_RDAb101.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb101.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb101.FLNK","BTM:BSY0:26:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb101.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb101.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:26:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:26:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:26:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:26:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb101.VAL") #! Field("BTM:BSY0:26:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:26:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:26:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:26:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:26:SPARE:PPSTRIPA") #! Field("BTM:BSY0:26:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi100") { field(DESC, "Port BTM_RDA bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:27:SPARE:PPSTRIPA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:27:SPARE:PPSTRIPA_calc") { field(INPA, "PLC:BSY0:PP03:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:27:SPARE:PPSTRIPA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:27:SPARE:PPSTRIPA") { field(DESC, "BTM-RT_SPARE_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb100",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb100") #! Field("PLC:BSY0:PP03:BTM_RDAb100.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb100.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb100.FLNK","BTM:BSY0:27:SPARE:PPSTRIPA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb100.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb100.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPA_calc",260,18,0,1,"BTM:BSY0:27:SPARE:PPSTRIPA_calc") #! Field("BTM:BSY0:27:SPARE:PPSTRIPA_calc.INPA",16777215,0,"BTM:BSY0:27:SPARE:PPSTRIPA_calc.INPA") #! Link("BTM:BSY0:27:SPARE:PPSTRIPA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb100.VAL") #! Field("BTM:BSY0:27:SPARE:PPSTRIPA_calc.INPB",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPA_calc.INPB") #! Field("BTM:BSY0:27:SPARE:PPSTRIPA_calc.OUT",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPA_calc.OUT") #! Link("BTM:BSY0:27:SPARE:PPSTRIPA_calc.OUT","BTM:BSY0:27:SPARE:PPSTRIPA.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPA",500,20,0,0,"BTM:BSY0:27:SPARE:PPSTRIPA") #! Field("BTM:BSY0:27:SPARE:PPSTRIPA.VAL",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi99") { field(DESC, "Port BTM_RDA bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYH:858:PPSTRIPPRSSR_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:PPSTRIPPRSSR_calc") { field(INPA, "PLC:BSY0:PP03:Bi99 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:PPSTRIPPRSSR PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:PPSTRIPPRSSR") { field(DESC, "BTM-DM60_Bot_Press_Ok") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb99",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb99") #! Field("PLC:BSY0:PP03:BTM_RDAb99.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb99.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb99.FLNK","BTM:BSYH:858:PPSTRIPPRSSR_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb99.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb99.VAL") #! Record("BTM:BSYH:858:PPSTRIPPRSSR_calc",260,18,0,1,"BTM:BSYH:858:PPSTRIPPRSSR_calc") #! Field("BTM:BSYH:858:PPSTRIPPRSSR_calc.INPA",16777215,0,"BTM:BSYH:858:PPSTRIPPRSSR_calc.INPA") #! Link("BTM:BSYH:858:PPSTRIPPRSSR_calc.INPA","PLC:BSY0:PP03:BTM_RDAb99.VAL") #! Field("BTM:BSYH:858:PPSTRIPPRSSR_calc.INPB",16777215,1,"BTM:BSYH:858:PPSTRIPPRSSR_calc.INPB") #! Field("BTM:BSYH:858:PPSTRIPPRSSR_calc.OUT",16777215,1,"BTM:BSYH:858:PPSTRIPPRSSR_calc.OUT") #! Link("BTM:BSYH:858:PPSTRIPPRSSR_calc.OUT","BTM:BSYH:858:PPSTRIPPRSSR.VAL") #! Record("BTM:BSYH:858:PPSTRIPPRSSR",500,20,0,0,"BTM:BSYH:858:PPSTRIPPRSSR") #! Field("BTM:BSYH:858:PPSTRIPPRSSR.VAL",16777215,1,"BTM:BSYH:858:PPSTRIPPRSSR.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi98") { field(DESC, "Port BTM_RDA bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:CLTS:585:PPSTRIPPRSSR_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:CLTS:585:PPSTRIPPRSSR_calc") { field(INPA, "PLC:BSY0:PP03:Bi98 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:CLTS:585:PPSTRIPPRSSR PP MS") field(ASG, "Internal") } record(bi, "BTM:CLTS:585:PPSTRIPPRSSR") { field(DESC, "BTM-STCLTS_Bot_Press_Ok") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb98",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb98") #! Field("PLC:BSY0:PP03:BTM_RDAb98.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb98.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb98.FLNK","BTM:CLTS:585:PPSTRIPPRSSR_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb98.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb98.VAL") #! Record("BTM:CLTS:585:PPSTRIPPRSSR_calc",260,18,0,1,"BTM:CLTS:585:PPSTRIPPRSSR_calc") #! Field("BTM:CLTS:585:PPSTRIPPRSSR_calc.INPA",16777215,0,"BTM:CLTS:585:PPSTRIPPRSSR_calc.INPA") #! Link("BTM:CLTS:585:PPSTRIPPRSSR_calc.INPA","PLC:BSY0:PP03:BTM_RDAb98.VAL") #! Field("BTM:CLTS:585:PPSTRIPPRSSR_calc.INPB",16777215,1,"BTM:CLTS:585:PPSTRIPPRSSR_calc.INPB") #! Field("BTM:CLTS:585:PPSTRIPPRSSR_calc.OUT",16777215,1,"BTM:CLTS:585:PPSTRIPPRSSR_calc.OUT") #! Link("BTM:CLTS:585:PPSTRIPPRSSR_calc.OUT","BTM:CLTS:585:PPSTRIPPRSSR.VAL") #! Record("BTM:CLTS:585:PPSTRIPPRSSR",500,20,0,0,"BTM:CLTS:585:PPSTRIPPRSSR") #! Field("BTM:CLTS:585:PPSTRIPPRSSR.VAL",16777215,1,"BTM:CLTS:585:PPSTRIPPRSSR.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi97") { field(DESC, "Port BTM_RDA bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:1490:PPSTRIPPRSSR_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1490:PPSTRIPPRSSR_calc") { field(INPA, "PLC:BSY0:PP03:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1490:PPSTRIPPRSSR PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1490:PPSTRIPPRSSR") { field(DESC, "BTM-DM12_and_14_Bot_Press_Ok") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb97",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb97") #! Field("PLC:BSY0:PP03:BTM_RDAb97.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb97.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb97.FLNK","BTM:BSYA:1490:PPSTRIPPRSSR_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb97.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb97.VAL") #! Record("BTM:BSYA:1490:PPSTRIPPRSSR_calc",260,18,0,1,"BTM:BSYA:1490:PPSTRIPPRSSR_calc") #! Field("BTM:BSYA:1490:PPSTRIPPRSSR_calc.INPA",16777215,0,"BTM:BSYA:1490:PPSTRIPPRSSR_calc.INPA") #! Link("BTM:BSYA:1490:PPSTRIPPRSSR_calc.INPA","PLC:BSY0:PP03:BTM_RDAb97.VAL") #! Field("BTM:BSYA:1490:PPSTRIPPRSSR_calc.INPB",16777215,1,"BTM:BSYA:1490:PPSTRIPPRSSR_calc.INPB") #! Field("BTM:BSYA:1490:PPSTRIPPRSSR_calc.OUT",16777215,1,"BTM:BSYA:1490:PPSTRIPPRSSR_calc.OUT") #! Link("BTM:BSYA:1490:PPSTRIPPRSSR_calc.OUT","BTM:BSYA:1490:PPSTRIPPRSSR.VAL") #! Record("BTM:BSYA:1490:PPSTRIPPRSSR",500,20,0,0,"BTM:BSYA:1490:PPSTRIPPRSSR") #! Field("BTM:BSYA:1490:PPSTRIPPRSSR.VAL",16777215,1,"BTM:BSYA:1490:PPSTRIPPRSSR.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi96") { field(DESC, "Port BTM_RDA bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:2930:PPSTRIPPRSSR_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2930:PPSTRIPPRSSR_calc") { field(INPA, "PLC:BSY0:PP03:Bi96 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2930:PPSTRIPPRSSR PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2930:PPSTRIPPRSSR") { field(DESC, "BTM-DM22_and_29_Bot_Press_Ok") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb96",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb96") #! Field("PLC:BSY0:PP03:BTM_RDAb96.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb96.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb96.FLNK","BTM:BSYA:2930:PPSTRIPPRSSR_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb96.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb96.VAL") #! Record("BTM:BSYA:2930:PPSTRIPPRSSR_calc",260,18,0,1,"BTM:BSYA:2930:PPSTRIPPRSSR_calc") #! Field("BTM:BSYA:2930:PPSTRIPPRSSR_calc.INPA",16777215,0,"BTM:BSYA:2930:PPSTRIPPRSSR_calc.INPA") #! Link("BTM:BSYA:2930:PPSTRIPPRSSR_calc.INPA","PLC:BSY0:PP03:BTM_RDAb96.VAL") #! Field("BTM:BSYA:2930:PPSTRIPPRSSR_calc.INPB",16777215,1,"BTM:BSYA:2930:PPSTRIPPRSSR_calc.INPB") #! Field("BTM:BSYA:2930:PPSTRIPPRSSR_calc.OUT",16777215,1,"BTM:BSYA:2930:PPSTRIPPRSSR_calc.OUT") #! Link("BTM:BSYA:2930:PPSTRIPPRSSR_calc.OUT","BTM:BSYA:2930:PPSTRIPPRSSR.VAL") #! Record("BTM:BSYA:2930:PPSTRIPPRSSR",500,20,0,0,"BTM:BSYA:2930:PPSTRIPPRSSR") #! Field("BTM:BSYA:2930:PPSTRIPPRSSR.VAL",16777215,1,"BTM:BSYA:2930:PPSTRIPPRSSR.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi111") { field(DESC, "Port BTM_RDA bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc") { field(INPA, "PLC:BSY0:PP03:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SPARE:PPSTRIPPRSSR PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SPARE:PPSTRIPPRSSR") { field(DESC, "BTM-Spare_Bot_Press_Ok") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb111",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb111") #! Field("PLC:BSY0:PP03:BTM_RDAb111.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb111.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb111.FLNK","BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb111.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb111.VAL") #! Record("BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc",260,18,0,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.INPA",16777215,0,"BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.INPA") #! Link("BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.INPA","PLC:BSY0:PP03:BTM_RDAb111.VAL") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.INPB",16777215,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.INPB") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.OUT",16777215,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.OUT") #! Link("BTM:BSY0:1:SPARE:PPSTRIPPRSSR_calc.OUT","BTM:BSY0:1:SPARE:PPSTRIPPRSSR.VAL") #! Record("BTM:BSY0:1:SPARE:PPSTRIPPRSSR",500,20,0,0,"BTM:BSY0:1:SPARE:PPSTRIPPRSSR") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSR.VAL",16777215,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSR.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi110") { field(DESC, "Port BTM_RDA bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc") { field(INPA, "PLC:BSY0:PP03:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SS0_HEARTBEAT_OUTA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SS0_HEARTBEAT_OUTA") { field(DESC, "BTM-SS0_Heartbeat_Out_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb110",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb110") #! Field("PLC:BSY0:PP03:BTM_RDAb110.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb110.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb110.FLNK","BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb110.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb110.VAL") #! Record("BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc",260,18,0,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.INPA",16777215,0,"BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.INPA") #! Link("BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb110.VAL") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.INPB",16777215,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.INPB") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.OUT",16777215,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.OUT") #! Link("BTM:BSY0:1:SS0_HEARTBEAT_OUTA_calc.OUT","BTM:BSY0:1:SS0_HEARTBEAT_OUTA.VAL") #! Record("BTM:BSY0:1:SS0_HEARTBEAT_OUTA",500,20,0,0,"BTM:BSY0:1:SS0_HEARTBEAT_OUTA") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTA.VAL",16777215,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi109") { field(DESC, "Port BTM_RDA bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 109, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:PPSTRIPPRSSRLTH_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:PPSTRIPPRSSRLTH_calc") { field(INPA, "PLC:BSY0:PP03:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:PPSTRIPPRSSRLTH PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:PPSTRIPPRSSRLTH") { field(DESC, "BTM-Bot_Press_Ok_Sum_Lat") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb109",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb109") #! Field("PLC:BSY0:PP03:BTM_RDAb109.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb109.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb109.FLNK","BTM:BSY0:1:PPSTRIPPRSSRLTH_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb109.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb109.VAL") #! Record("BTM:BSY0:1:PPSTRIPPRSSRLTH_calc",260,18,0,1,"BTM:BSY0:1:PPSTRIPPRSSRLTH_calc") #! Field("BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.INPA",16777215,0,"BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.INPA") #! Link("BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.INPA","PLC:BSY0:PP03:BTM_RDAb109.VAL") #! Field("BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.INPB",16777215,1,"BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.INPB") #! Field("BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.OUT",16777215,1,"BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.OUT") #! Link("BTM:BSY0:1:PPSTRIPPRSSRLTH_calc.OUT","BTM:BSY0:1:PPSTRIPPRSSRLTH.VAL") #! Record("BTM:BSY0:1:PPSTRIPPRSSRLTH",500,20,0,0,"BTM:BSY0:1:PPSTRIPPRSSRLTH") #! Field("BTM:BSY0:1:PPSTRIPPRSSRLTH.VAL",16777215,1,"BTM:BSY0:1:PPSTRIPPRSSRLTH.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi108") { field(DESC, "Port BTM_RDA bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 108, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA") { field(DESC, "BTM-SS2_Heartbeat_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb108",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb108") #! Field("PLC:BSY0:PP03:BTM_RDAb108.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb108.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb108.FLNK","BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb108.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb108.VAL") #! Record("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc",260,18,0,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.INPA",16777215,0,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.INPA") #! Link("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb108.VAL") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.INPB",16777215,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.INPB") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.OUT",16777215,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.OUT") #! Link("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA_calc.OUT","BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA.VAL") #! Record("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA",500,20,0,0,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA.VAL",16777215,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi107") { field(DESC, "Port BTM_RDA bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SS3_SPAREA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SS3_SPAREA_calc") { field(INPA, "PLC:BSY0:PP03:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SS3_SPAREA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SS3_SPAREA") { field(DESC, "BTM-SS3_Spare_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb107",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb107") #! Field("PLC:BSY0:PP03:BTM_RDAb107.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb107.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb107.FLNK","BTM:BSY0:1:SS3_SPAREA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb107.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb107.VAL") #! Record("BTM:BSY0:1:SS3_SPAREA_calc",260,18,0,1,"BTM:BSY0:1:SS3_SPAREA_calc") #! Field("BTM:BSY0:1:SS3_SPAREA_calc.INPA",16777215,0,"BTM:BSY0:1:SS3_SPAREA_calc.INPA") #! Link("BTM:BSY0:1:SS3_SPAREA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb107.VAL") #! Field("BTM:BSY0:1:SS3_SPAREA_calc.INPB",16777215,1,"BTM:BSY0:1:SS3_SPAREA_calc.INPB") #! Field("BTM:BSY0:1:SS3_SPAREA_calc.OUT",16777215,1,"BTM:BSY0:1:SS3_SPAREA_calc.OUT") #! Link("BTM:BSY0:1:SS3_SPAREA_calc.OUT","BTM:BSY0:1:SS3_SPAREA.VAL") #! Record("BTM:BSY0:1:SS3_SPAREA",500,20,0,0,"BTM:BSY0:1:SS3_SPAREA") #! Field("BTM:BSY0:1:SS3_SPAREA.VAL",16777215,1,"BTM:BSY0:1:SS3_SPAREA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi106") { field(DESC, "Port BTM_RDA bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 106, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:INTLK_OK_SUM_LTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:INTLK_OK_SUM_LTHA") { field(DESC, "BTM-Intlk_Ok_Lat_Summary_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb106",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb106") #! Field("PLC:BSY0:PP03:BTM_RDAb106.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb106.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb106.FLNK","BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb106.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb106.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc",260,18,0,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.INPA",16777215,0,"BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.INPA") #! Link("BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb106.VAL") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.INPB",16777215,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.INPB") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.OUT",16777215,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.OUT") #! Link("BTM:BSY0:1:INTLK_OK_SUM_LTHA_calc.OUT","BTM:BSY0:1:INTLK_OK_SUM_LTHA.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUM_LTHA",500,20,0,0,"BTM:BSY0:1:INTLK_OK_SUM_LTHA") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHA.VAL",16777215,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi105") { field(DESC, "Port BTM_RDA bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 105, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:INTLK_OK_SUMA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:INTLK_OK_SUMA_calc") { field(INPA, "PLC:BSY0:PP03:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:INTLK_OK_SUMA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:INTLK_OK_SUMA") { field(DESC, "BTM-Intlk_Ok_RT_Summary_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb105",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb105") #! Field("PLC:BSY0:PP03:BTM_RDAb105.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb105.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb105.FLNK","BTM:BSY0:1:INTLK_OK_SUMA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb105.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb105.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUMA_calc",260,18,0,1,"BTM:BSY0:1:INTLK_OK_SUMA_calc") #! Field("BTM:BSY0:1:INTLK_OK_SUMA_calc.INPA",16777215,0,"BTM:BSY0:1:INTLK_OK_SUMA_calc.INPA") #! Link("BTM:BSY0:1:INTLK_OK_SUMA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb105.VAL") #! Field("BTM:BSY0:1:INTLK_OK_SUMA_calc.INPB",16777215,1,"BTM:BSY0:1:INTLK_OK_SUMA_calc.INPB") #! Field("BTM:BSY0:1:INTLK_OK_SUMA_calc.OUT",16777215,1,"BTM:BSY0:1:INTLK_OK_SUMA_calc.OUT") #! Link("BTM:BSY0:1:INTLK_OK_SUMA_calc.OUT","BTM:BSY0:1:INTLK_OK_SUMA.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUMA",500,20,0,0,"BTM:BSY0:1:INTLK_OK_SUMA") #! Field("BTM:BSY0:1:INTLK_OK_SUMA.VAL",16777215,1,"BTM:BSY0:1:INTLK_OK_SUMA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi104") { field(DESC, "Port BTM_RDA bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 104, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:RO3_SPAREA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:RO3_SPAREA_calc") { field(INPA, "PLC:BSY0:PP03:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:RO3_SPAREA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:RO3_SPAREA") { field(DESC, "BTM-Relay_Output_3_Spare_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb104",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb104") #! Field("PLC:BSY0:PP03:BTM_RDAb104.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb104.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb104.FLNK","BTM:BSY0:1:RO3_SPAREA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb104.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb104.VAL") #! Record("BTM:BSY0:1:RO3_SPAREA_calc",260,18,0,1,"BTM:BSY0:1:RO3_SPAREA_calc") #! Field("BTM:BSY0:1:RO3_SPAREA_calc.INPA",16777215,0,"BTM:BSY0:1:RO3_SPAREA_calc.INPA") #! Link("BTM:BSY0:1:RO3_SPAREA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb104.VAL") #! Field("BTM:BSY0:1:RO3_SPAREA_calc.INPB",16777215,1,"BTM:BSY0:1:RO3_SPAREA_calc.INPB") #! Field("BTM:BSY0:1:RO3_SPAREA_calc.OUT",16777215,1,"BTM:BSY0:1:RO3_SPAREA_calc.OUT") #! Link("BTM:BSY0:1:RO3_SPAREA_calc.OUT","BTM:BSY0:1:RO3_SPAREA.VAL") #! Record("BTM:BSY0:1:RO3_SPAREA",500,20,0,0,"BTM:BSY0:1:RO3_SPAREA") #! Field("BTM:BSY0:1:RO3_SPAREA.VAL",16777215,1,"BTM:BSY0:1:RO3_SPAREA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi119") { field(DESC, "Port BTM_RDA bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 119, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:RO4_SPAREA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:RO4_SPAREA_calc") { field(INPA, "PLC:BSY0:PP03:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:RO4_SPAREA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:RO4_SPAREA") { field(DESC, "BTM-Relay_Output_4_Spare_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb119",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb119") #! Field("PLC:BSY0:PP03:BTM_RDAb119.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb119.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb119.FLNK","BTM:BSY0:1:RO4_SPAREA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb119.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb119.VAL") #! Record("BTM:BSY0:1:RO4_SPAREA_calc",260,18,0,1,"BTM:BSY0:1:RO4_SPAREA_calc") #! Field("BTM:BSY0:1:RO4_SPAREA_calc.INPA",16777215,0,"BTM:BSY0:1:RO4_SPAREA_calc.INPA") #! Link("BTM:BSY0:1:RO4_SPAREA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb119.VAL") #! Field("BTM:BSY0:1:RO4_SPAREA_calc.INPB",16777215,1,"BTM:BSY0:1:RO4_SPAREA_calc.INPB") #! Field("BTM:BSY0:1:RO4_SPAREA_calc.OUT",16777215,1,"BTM:BSY0:1:RO4_SPAREA_calc.OUT") #! Link("BTM:BSY0:1:RO4_SPAREA_calc.OUT","BTM:BSY0:1:RO4_SPAREA.VAL") #! Record("BTM:BSY0:1:RO4_SPAREA",500,20,0,0,"BTM:BSY0:1:RO4_SPAREA") #! Field("BTM:BSY0:1:RO4_SPAREA.VAL",16777215,1,"BTM:BSY0:1:RO4_SPAREA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi118") { field(DESC, "Port BTM_RDA bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 118, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:PPSTRIPPRSSR_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:PPSTRIPPRSSR_calc") { field(INPA, "PLC:BSY0:PP03:Bi118 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:PPSTRIPPRSSR PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:PPSTRIPPRSSR") { field(DESC, "BTM-Bot_Press_Ok_RT_Sum") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb118",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb118") #! Field("PLC:BSY0:PP03:BTM_RDAb118.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb118.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb118.FLNK","BTM:BSY0:1:PPSTRIPPRSSR_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb118.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb118.VAL") #! Record("BTM:BSY0:1:PPSTRIPPRSSR_calc",260,18,0,1,"BTM:BSY0:1:PPSTRIPPRSSR_calc") #! Field("BTM:BSY0:1:PPSTRIPPRSSR_calc.INPA",16777215,0,"BTM:BSY0:1:PPSTRIPPRSSR_calc.INPA") #! Link("BTM:BSY0:1:PPSTRIPPRSSR_calc.INPA","PLC:BSY0:PP03:BTM_RDAb118.VAL") #! Field("BTM:BSY0:1:PPSTRIPPRSSR_calc.INPB",16777215,1,"BTM:BSY0:1:PPSTRIPPRSSR_calc.INPB") #! Field("BTM:BSY0:1:PPSTRIPPRSSR_calc.OUT",16777215,1,"BTM:BSY0:1:PPSTRIPPRSSR_calc.OUT") #! Link("BTM:BSY0:1:PPSTRIPPRSSR_calc.OUT","BTM:BSY0:1:PPSTRIPPRSSR.VAL") #! Record("BTM:BSY0:1:PPSTRIPPRSSR",500,20,0,0,"BTM:BSY0:1:PPSTRIPPRSSR") #! Field("BTM:BSY0:1:PPSTRIPPRSSR.VAL",16777215,1,"BTM:BSY0:1:PPSTRIPPRSSR.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi116") { field(DESC, "Port BTM_RDA bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYH:858:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:PPSTRIPLTHA") { field(DESC, "BTM-DM60_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb116",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb116") #! Field("PLC:BSY0:PP03:BTM_RDAb116.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb116.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb116.FLNK","BTM:BSYH:858:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb116.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb116.VAL") #! Record("BTM:BSYH:858:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYH:858:PPSTRIPLTHA_calc") #! Field("BTM:BSYH:858:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYH:858:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYH:858:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb116.VAL") #! Field("BTM:BSYH:858:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYH:858:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYH:858:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYH:858:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYH:858:PPSTRIPLTHA_calc.OUT","BTM:BSYH:858:PPSTRIPLTHA.VAL") #! Record("BTM:BSYH:858:PPSTRIPLTHA",500,20,0,0,"BTM:BSYH:858:PPSTRIPLTHA") #! Field("BTM:BSYH:858:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYH:858:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi115") { field(DESC, "Port BTM_RDA bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:2:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:2:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb115",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb115") #! Field("PLC:BSY0:PP03:BTM_RDAb115.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb115.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb115.FLNK","BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb115.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb115.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb115.VAL") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:2:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:2:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:2:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi114") { field(DESC, "Port BTM_RDA bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:1240:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1240:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1240:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1240:PPSTRIPLTHA") { field(DESC, "BTM-DM12_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb114",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb114") #! Field("PLC:BSY0:PP03:BTM_RDAb114.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb114.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb114.FLNK","BTM:BSYA:1240:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb114.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb114.VAL") #! Record("BTM:BSYA:1240:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYA:1240:PPSTRIPLTHA_calc") #! Field("BTM:BSYA:1240:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYA:1240:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYA:1240:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb114.VAL") #! Field("BTM:BSYA:1240:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYA:1240:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYA:1240:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYA:1240:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYA:1240:PPSTRIPLTHA_calc.OUT","BTM:BSYA:1240:PPSTRIPLTHA.VAL") #! Record("BTM:BSYA:1240:PPSTRIPLTHA",500,20,0,0,"BTM:BSYA:1240:PPSTRIPLTHA") #! Field("BTM:BSYA:1240:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYA:1240:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi113") { field(DESC, "Port BTM_RDA bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:1490:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1490:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1490:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1490:PPSTRIPLTHA") { field(DESC, "BTM-DM14_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb113",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb113") #! Field("PLC:BSY0:PP03:BTM_RDAb113.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb113.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb113.FLNK","BTM:BSYA:1490:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb113.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb113.VAL") #! Record("BTM:BSYA:1490:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYA:1490:PPSTRIPLTHA_calc") #! Field("BTM:BSYA:1490:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYA:1490:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYA:1490:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb113.VAL") #! Field("BTM:BSYA:1490:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYA:1490:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYA:1490:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYA:1490:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYA:1490:PPSTRIPLTHA_calc.OUT","BTM:BSYA:1490:PPSTRIPLTHA.VAL") #! Record("BTM:BSYA:1490:PPSTRIPLTHA",500,20,0,0,"BTM:BSYA:1490:PPSTRIPLTHA") #! Field("BTM:BSYA:1490:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYA:1490:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi112") { field(DESC, "Port BTM_RDA bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 112, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:2275:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2275:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi112 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2275:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2275:PPSTRIPLTHA") { field(DESC, "BTM-DM22_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb112",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb112") #! Field("PLC:BSY0:PP03:BTM_RDAb112.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb112.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb112.FLNK","BTM:BSYA:2275:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb112.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb112.VAL") #! Record("BTM:BSYA:2275:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYA:2275:PPSTRIPLTHA_calc") #! Field("BTM:BSYA:2275:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYA:2275:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYA:2275:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb112.VAL") #! Field("BTM:BSYA:2275:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYA:2275:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYA:2275:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYA:2275:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYA:2275:PPSTRIPLTHA_calc.OUT","BTM:BSYA:2275:PPSTRIPLTHA.VAL") #! Record("BTM:BSYA:2275:PPSTRIPLTHA",500,20,0,0,"BTM:BSYA:2275:PPSTRIPLTHA") #! Field("BTM:BSYA:2275:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYA:2275:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi127") { field(DESC, "Port BTM_RDA bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 127, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:2930:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2930:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2930:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2930:PPSTRIPLTHA") { field(DESC, "BTM-DM29_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb127",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb127") #! Field("PLC:BSY0:PP03:BTM_RDAb127.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb127.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb127.FLNK","BTM:BSYA:2930:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb127.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb127.VAL") #! Record("BTM:BSYA:2930:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYA:2930:PPSTRIPLTHA_calc") #! Field("BTM:BSYA:2930:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYA:2930:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYA:2930:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb127.VAL") #! Field("BTM:BSYA:2930:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYA:2930:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYA:2930:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYA:2930:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYA:2930:PPSTRIPLTHA_calc.OUT","BTM:BSYA:2930:PPSTRIPLTHA.VAL") #! Record("BTM:BSYA:2930:PPSTRIPLTHA",500,20,0,0,"BTM:BSYA:2930:PPSTRIPLTHA") #! Field("BTM:BSYA:2930:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYA:2930:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi126") { field(DESC, "Port BTM_RDA bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 126, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYS:889:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:889:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi126 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:889:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:889:PPSTRIPLTHA") { field(DESC, "BTM-ST34A_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb126",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb126") #! Field("PLC:BSY0:PP03:BTM_RDAb126.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb126.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb126.FLNK","BTM:BSYS:889:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb126.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb126.VAL") #! Record("BTM:BSYS:889:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYS:889:PPSTRIPLTHA_calc") #! Field("BTM:BSYS:889:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYS:889:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYS:889:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb126.VAL") #! Field("BTM:BSYS:889:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYS:889:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYS:889:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYS:889:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYS:889:PPSTRIPLTHA_calc.OUT","BTM:BSYS:889:PPSTRIPLTHA.VAL") #! Record("BTM:BSYS:889:PPSTRIPLTHA",500,20,0,0,"BTM:BSYS:889:PPSTRIPLTHA") #! Field("BTM:BSYS:889:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYS:889:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi125") { field(DESC, "Port BTM_RDA bit 125") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 125, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYS:898:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:898:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi125 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:898:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:898:PPSTRIPLTHA") { field(DESC, "BTM-ST34B_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb125",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb125") #! Field("PLC:BSY0:PP03:BTM_RDAb125.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb125.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb125.FLNK","BTM:BSYS:898:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb125.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb125.VAL") #! Record("BTM:BSYS:898:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSYS:898:PPSTRIPLTHA_calc") #! Field("BTM:BSYS:898:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSYS:898:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSYS:898:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb125.VAL") #! Field("BTM:BSYS:898:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSYS:898:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSYS:898:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSYS:898:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSYS:898:PPSTRIPLTHA_calc.OUT","BTM:BSYS:898:PPSTRIPLTHA.VAL") #! Record("BTM:BSYS:898:PPSTRIPLTHA",500,20,0,0,"BTM:BSYS:898:PPSTRIPLTHA") #! Field("BTM:BSYS:898:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSYS:898:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi124") { field(DESC, "Port BTM_RDA bit 124") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 124, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:CLTS:585:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:CLTS:585:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi124 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:CLTS:585:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:CLTS:585:PPSTRIPLTHA") { field(DESC, "BTM-STCLTS_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb124",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb124") #! Field("PLC:BSY0:PP03:BTM_RDAb124.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb124.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb124.FLNK","BTM:CLTS:585:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb124.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb124.VAL") #! Record("BTM:CLTS:585:PPSTRIPLTHA_calc",260,18,0,1,"BTM:CLTS:585:PPSTRIPLTHA_calc") #! Field("BTM:CLTS:585:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:CLTS:585:PPSTRIPLTHA_calc.INPA") #! Link("BTM:CLTS:585:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb124.VAL") #! Field("BTM:CLTS:585:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:CLTS:585:PPSTRIPLTHA_calc.INPB") #! Field("BTM:CLTS:585:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:CLTS:585:PPSTRIPLTHA_calc.OUT") #! Link("BTM:CLTS:585:PPSTRIPLTHA_calc.OUT","BTM:CLTS:585:PPSTRIPLTHA.VAL") #! Record("BTM:CLTS:585:PPSTRIPLTHA",500,20,0,0,"BTM:CLTS:585:PPSTRIPLTHA") #! Field("BTM:CLTS:585:PPSTRIPLTHA.VAL",16777215,1,"BTM:CLTS:585:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi123") { field(DESC, "Port BTM_RDA bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 123, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:10:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:10:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb123",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb123") #! Field("PLC:BSY0:PP03:BTM_RDAb123.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb123.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb123.FLNK","BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb123.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb123.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb123.VAL") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:10:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:10:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:10:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi122") { field(DESC, "Port BTM_RDA bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 122, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi122 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:11:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:11:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb122",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb122") #! Field("PLC:BSY0:PP03:BTM_RDAb122.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb122.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb122.FLNK","BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb122.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb122.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb122.VAL") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:11:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:11:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:11:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi121") { field(DESC, "Port BTM_RDA bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 121, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:12:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:12:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb121",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb121") #! Field("PLC:BSY0:PP03:BTM_RDAb121.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb121.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb121.FLNK","BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb121.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb121.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb121.VAL") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:12:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:12:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:12:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi120") { field(DESC, "Port BTM_RDA bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 120, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:13:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:13:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb120",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb120") #! Field("PLC:BSY0:PP03:BTM_RDAb120.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb120.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb120.FLNK","BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb120.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb120.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb120.VAL") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:13:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:13:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:13:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi135") { field(DESC, "Port BTM_RDA bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 135, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:14:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:14:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb135",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb135") #! Field("PLC:BSY0:PP03:BTM_RDAb135.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb135.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb135.FLNK","BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb135.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb135.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb135.VAL") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:14:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:14:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:14:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi134") { field(DESC, "Port BTM_RDA bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 134, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:15:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:15:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb134",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb134") #! Field("PLC:BSY0:PP03:BTM_RDAb134.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb134.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb134.FLNK","BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb134.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb134.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb134.VAL") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:15:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:15:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:15:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi133") { field(DESC, "Port BTM_RDA bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 133, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:16:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:16:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb133",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb133") #! Field("PLC:BSY0:PP03:BTM_RDAb133.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb133.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb133.FLNK","BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb133.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb133.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb133.VAL") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:16:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:16:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:16:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi132") { field(DESC, "Port BTM_RDA bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 132, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:17:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:17:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb132",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb132") #! Field("PLC:BSY0:PP03:BTM_RDAb132.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb132.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb132.FLNK","BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb132.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb132.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb132.VAL") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:17:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:17:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:17:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi131") { field(DESC, "Port BTM_RDA bit 131") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 131, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi131 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:18:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:18:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb131",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb131") #! Field("PLC:BSY0:PP03:BTM_RDAb131.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb131.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb131.FLNK","BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb131.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb131.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb131.VAL") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:18:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:18:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:18:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi130") { field(DESC, "Port BTM_RDA bit 130") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 130, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi130 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:19:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:19:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb130",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb130") #! Field("PLC:BSY0:PP03:BTM_RDAb130.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb130.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb130.FLNK","BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb130.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb130.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb130.VAL") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:19:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:19:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:19:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi129") { field(DESC, "Port BTM_RDA bit 129") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 129, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi129 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:20:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:20:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb129",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb129") #! Field("PLC:BSY0:PP03:BTM_RDAb129.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb129.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb129.FLNK","BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb129.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb129.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb129.VAL") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:20:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:20:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:20:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi128") { field(DESC, "Port BTM_RDA bit 128") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 128, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi128 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:21:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:21:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb128",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb128") #! Field("PLC:BSY0:PP03:BTM_RDAb128.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb128.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb128.FLNK","BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb128.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb128.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb128.VAL") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:21:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:21:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:21:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi143") { field(DESC, "Port BTM_RDA bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 143, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:22:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:22:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb143",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb143") #! Field("PLC:BSY0:PP03:BTM_RDAb143.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb143.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb143.FLNK","BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb143.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb143.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb143.VAL") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:22:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:22:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:22:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi142") { field(DESC, "Port BTM_RDA bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 142, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:23:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:23:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb142",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb142") #! Field("PLC:BSY0:PP03:BTM_RDAb142.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb142.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb142.FLNK","BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb142.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb142.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb142.VAL") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:23:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:23:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:23:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi141") { field(DESC, "Port BTM_RDA bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 141, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:24:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:24:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb141",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb141") #! Field("PLC:BSY0:PP03:BTM_RDAb141.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb141.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb141.FLNK","BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb141.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb141.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb141.VAL") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:24:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:24:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:24:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi140") { field(DESC, "Port BTM_RDA bit 140") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 140, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi140 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:25:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:25:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb140",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb140") #! Field("PLC:BSY0:PP03:BTM_RDAb140.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb140.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb140.FLNK","BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb140.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb140.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb140.VAL") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:25:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:25:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:25:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi139") { field(DESC, "Port BTM_RDA bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 139, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:26:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:26:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb139",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb139") #! Field("PLC:BSY0:PP03:BTM_RDAb139.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb139.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb139.FLNK","BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb139.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb139.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb139.VAL") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:26:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:26:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:26:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi138") { field(DESC, "Port BTM_RDA bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc") { field(INPA, "PLC:BSY0:PP03:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:27:SPARE:PPSTRIPLTHA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:27:SPARE:PPSTRIPLTHA") { field(DESC, "BTM-SPARE_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb138",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb138") #! Field("PLC:BSY0:PP03:BTM_RDAb138.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb138.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb138.FLNK","BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb138.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb138.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc",260,18,0,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.INPA",16777215,0,"BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.INPA") #! Link("BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.INPA","PLC:BSY0:PP03:BTM_RDAb138.VAL") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.INPB",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.INPB") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.OUT",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.OUT") #! Link("BTM:BSY0:27:SPARE:PPSTRIPLTHA_calc.OUT","BTM:BSY0:27:SPARE:PPSTRIPLTHA.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPLTHA",500,20,0,0,"BTM:BSY0:27:SPARE:PPSTRIPLTHA") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHA.VAL",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi137") { field(DESC, "Port BTM_RDA bit 137") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 137, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYH:858:PPSTRIPPRSSRLTH_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:PPSTRIPPRSSRLTH_calc") { field(INPA, "PLC:BSY0:PP03:Bi137 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:PPSTRIPPRSSRLTH PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:PPSTRIPPRSSRLTH") { field(DESC, "BTM-DM60_Bot_Press_Ok_Lat") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb137",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb137") #! Field("PLC:BSY0:PP03:BTM_RDAb137.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb137.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb137.FLNK","BTM:BSYH:858:PPSTRIPPRSSRLTH_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb137.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb137.VAL") #! Record("BTM:BSYH:858:PPSTRIPPRSSRLTH_calc",260,18,0,1,"BTM:BSYH:858:PPSTRIPPRSSRLTH_calc") #! Field("BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.INPA",16777215,0,"BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.INPA") #! Link("BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.INPA","PLC:BSY0:PP03:BTM_RDAb137.VAL") #! Field("BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.INPB",16777215,1,"BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.INPB") #! Field("BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.OUT",16777215,1,"BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.OUT") #! Link("BTM:BSYH:858:PPSTRIPPRSSRLTH_calc.OUT","BTM:BSYH:858:PPSTRIPPRSSRLTH.VAL") #! Record("BTM:BSYH:858:PPSTRIPPRSSRLTH",500,20,0,0,"BTM:BSYH:858:PPSTRIPPRSSRLTH") #! Field("BTM:BSYH:858:PPSTRIPPRSSRLTH.VAL",16777215,1,"BTM:BSYH:858:PPSTRIPPRSSRLTH.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi136") { field(DESC, "Port BTM_RDA bit 136") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 136, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:CLTS:585:PPSTRIPPRSSRLTH_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:CLTS:585:PPSTRIPPRSSRLTH_calc") { field(INPA, "PLC:BSY0:PP03:Bi136 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:CLTS:585:PPSTRIPPRSSRLTH PP MS") field(ASG, "Internal") } record(bi, "BTM:CLTS:585:PPSTRIPPRSSRLTH") { field(DESC, "BTM-STCLTS_Bot_Press_Ok_Lat") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb136",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb136") #! Field("PLC:BSY0:PP03:BTM_RDAb136.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb136.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb136.FLNK","BTM:CLTS:585:PPSTRIPPRSSRLTH_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb136.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb136.VAL") #! Record("BTM:CLTS:585:PPSTRIPPRSSRLTH_calc",260,18,0,1,"BTM:CLTS:585:PPSTRIPPRSSRLTH_calc") #! Field("BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.INPA",16777215,0,"BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.INPA") #! Link("BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.INPA","PLC:BSY0:PP03:BTM_RDAb136.VAL") #! Field("BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.INPB",16777215,1,"BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.INPB") #! Field("BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.OUT",16777215,1,"BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.OUT") #! Link("BTM:CLTS:585:PPSTRIPPRSSRLTH_calc.OUT","BTM:CLTS:585:PPSTRIPPRSSRLTH.VAL") #! Record("BTM:CLTS:585:PPSTRIPPRSSRLTH",500,20,0,0,"BTM:CLTS:585:PPSTRIPPRSSRLTH") #! Field("BTM:CLTS:585:PPSTRIPPRSSRLTH.VAL",16777215,1,"BTM:CLTS:585:PPSTRIPPRSSRLTH.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi151") { field(DESC, "Port BTM_RDA bit 151") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 151, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc") { field(INPA, "PLC:BSY0:PP03:Bi151 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1490:PPSTRIPPRSSRLTH PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1490:PPSTRIPPRSSRLTH") { field(DESC, "BTM-DM12_14_Bot_Press_Ok_Lat") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb151",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb151") #! Field("PLC:BSY0:PP03:BTM_RDAb151.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb151.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb151.FLNK","BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb151.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb151.VAL") #! Record("BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc",260,18,0,1,"BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc") #! Field("BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.INPA",16777215,0,"BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.INPA") #! Link("BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.INPA","PLC:BSY0:PP03:BTM_RDAb151.VAL") #! Field("BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.INPB",16777215,1,"BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.INPB") #! Field("BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.OUT",16777215,1,"BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.OUT") #! Link("BTM:BSYA:1490:PPSTRIPPRSSRLTH_calc.OUT","BTM:BSYA:1490:PPSTRIPPRSSRLTH.VAL") #! Record("BTM:BSYA:1490:PPSTRIPPRSSRLTH",500,20,0,0,"BTM:BSYA:1490:PPSTRIPPRSSRLTH") #! Field("BTM:BSYA:1490:PPSTRIPPRSSRLTH.VAL",16777215,1,"BTM:BSYA:1490:PPSTRIPPRSSRLTH.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi150") { field(DESC, "Port BTM_RDA bit 150") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 150, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc") { field(INPA, "PLC:BSY0:PP03:Bi150 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2930:PPSTRIPPRSSRLTH PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2930:PPSTRIPPRSSRLTH") { field(DESC, "BTM-DM22_29_Bot_Press_Ok_Lat") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb150",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb150") #! Field("PLC:BSY0:PP03:BTM_RDAb150.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb150.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb150.FLNK","BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb150.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb150.VAL") #! Record("BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc",260,18,0,1,"BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc") #! Field("BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.INPA",16777215,0,"BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.INPA") #! Link("BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.INPA","PLC:BSY0:PP03:BTM_RDAb150.VAL") #! Field("BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.INPB",16777215,1,"BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.INPB") #! Field("BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.OUT",16777215,1,"BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.OUT") #! Link("BTM:BSYA:2930:PPSTRIPPRSSRLTH_calc.OUT","BTM:BSYA:2930:PPSTRIPPRSSRLTH.VAL") #! Record("BTM:BSYA:2930:PPSTRIPPRSSRLTH",500,20,0,0,"BTM:BSYA:2930:PPSTRIPPRSSRLTH") #! Field("BTM:BSYA:2930:PPSTRIPPRSSRLTH.VAL",16777215,1,"BTM:BSYA:2930:PPSTRIPPRSSRLTH.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP03:Bi149") { field(DESC, "Port BTM_RDA bit 149") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 149, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc") { field(INPA, "PLC:BSY0:PP03:Bi149 NPP MS") field(INPB, "PLC:BSY0:PP03:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH") { field(DESC, "BTM-Spare_Bot_Press_Ok_Lat") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP03:BTM_RDAb149",20,19,0,0,"PLC:BSY0:PP03:BTM_RDAb149") #! Field("PLC:BSY0:PP03:BTM_RDAb149.FLNK",16777215,1,"PLC:BSY0:PP03:BTM_RDAb149.FLNK") #! Link("PLC:BSY0:PP03:BTM_RDAb149.FLNK","BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc") #! Field("PLC:BSY0:PP03:BTM_RDAb149.VAL",16777215,0,"PLC:BSY0:PP03:BTM_RDAb149.VAL") #! Record("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc",260,18,0,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.INPA",16777215,0,"BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.INPA") #! Link("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.INPA","PLC:BSY0:PP03:BTM_RDAb149.VAL") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.INPB",16777215,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.INPB") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.OUT",16777215,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.OUT") #! Link("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH_calc.OUT","BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH.VAL") #! Record("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH",500,20,0,0,"BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH") #! Field("BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH.VAL",16777215,1,"BTM:BSY0:1:SPARE:PPSTRIPPRSSRLTH.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi7") { field(DESC, "Port BTM_RDB bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BTM:BSY0:1:HARDWARE_ENABLEB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:HARDWARE_ENABLEB_calc") { field(INPA, "PLC:BSY0:PP04:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:HARDWARE_ENABLEB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:HARDWARE_ENABLEB") { field(DESC, "BTM-Hardware_Enable_B") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb7",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb7") #! Field("PLC:BSY0:PP04:BTM_RDBb7.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb7.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb7.FLNK","BTM:BSY0:1:HARDWARE_ENABLEB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb7.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb7.VAL") #! Record("BTM:BSY0:1:HARDWARE_ENABLEB_calc",260,18,0,1,"BTM:BSY0:1:HARDWARE_ENABLEB_calc") #! Field("BTM:BSY0:1:HARDWARE_ENABLEB_calc.INPA",16777215,0,"BTM:BSY0:1:HARDWARE_ENABLEB_calc.INPA") #! Link("BTM:BSY0:1:HARDWARE_ENABLEB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb7.VAL") #! Field("BTM:BSY0:1:HARDWARE_ENABLEB_calc.INPB",16777215,1,"BTM:BSY0:1:HARDWARE_ENABLEB_calc.INPB") #! Field("BTM:BSY0:1:HARDWARE_ENABLEB_calc.OUT",16777215,1,"BTM:BSY0:1:HARDWARE_ENABLEB_calc.OUT") #! Link("BTM:BSY0:1:HARDWARE_ENABLEB_calc.OUT","BTM:BSY0:1:HARDWARE_ENABLEB.VAL") #! Record("BTM:BSY0:1:HARDWARE_ENABLEB",500,20,0,0,"BTM:BSY0:1:HARDWARE_ENABLEB") #! Field("BTM:BSY0:1:HARDWARE_ENABLEB.VAL",16777215,1,"BTM:BSY0:1:HARDWARE_ENABLEB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi6") { field(DESC, "Port BTM_RDB bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 6, 1, 1)") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(FLNK, "BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc") { field(INPA, "PLC:BSY0:PP04:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:HARDWIRE_INTLK_RESETB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:HARDWIRE_INTLK_RESETB") { field(DESC, "BTM-HW_Intlk_Reset_B") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb6",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb6") #! Field("PLC:BSY0:PP04:BTM_RDBb6.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb6.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb6.FLNK","BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb6.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb6.VAL") #! Record("BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc",260,18,0,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.INPA",16777215,0,"BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.INPA") #! Link("BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb6.VAL") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.INPB",16777215,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.INPB") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.OUT",16777215,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.OUT") #! Link("BTM:BSY0:1:HARDWIRE_INTLK_RESETB_calc.OUT","BTM:BSY0:1:HARDWIRE_INTLK_RESETB.VAL") #! Record("BTM:BSY0:1:HARDWIRE_INTLK_RESETB",500,20,0,0,"BTM:BSY0:1:HARDWIRE_INTLK_RESETB") #! Field("BTM:BSY0:1:HARDWIRE_INTLK_RESETB.VAL",16777215,1,"BTM:BSY0:1:HARDWIRE_INTLK_RESETB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi5") { field(DESC, "Port BTM_RDB bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:HEARTBEAT_INB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:HEARTBEAT_INB_calc") { field(INPA, "PLC:BSY0:PP04:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:HEARTBEAT_INB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:HEARTBEAT_INB") { field(DESC, "BTM-RT_Heartbeat_In_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb5",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb5") #! Field("PLC:BSY0:PP04:BTM_RDBb5.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb5.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb5.FLNK","BTM:BSY0:1:HEARTBEAT_INB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb5.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb5.VAL") #! Record("BTM:BSY0:1:HEARTBEAT_INB_calc",260,18,0,1,"BTM:BSY0:1:HEARTBEAT_INB_calc") #! Field("BTM:BSY0:1:HEARTBEAT_INB_calc.INPA",16777215,0,"BTM:BSY0:1:HEARTBEAT_INB_calc.INPA") #! Link("BTM:BSY0:1:HEARTBEAT_INB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb5.VAL") #! Field("BTM:BSY0:1:HEARTBEAT_INB_calc.INPB",16777215,1,"BTM:BSY0:1:HEARTBEAT_INB_calc.INPB") #! Field("BTM:BSY0:1:HEARTBEAT_INB_calc.OUT",16777215,1,"BTM:BSY0:1:HEARTBEAT_INB_calc.OUT") #! Link("BTM:BSY0:1:HEARTBEAT_INB_calc.OUT","BTM:BSY0:1:HEARTBEAT_INB.VAL") #! Record("BTM:BSY0:1:HEARTBEAT_INB",500,20,0,0,"BTM:BSY0:1:HEARTBEAT_INB") #! Field("BTM:BSY0:1:HEARTBEAT_INB.VAL",16777215,1,"BTM:BSY0:1:HEARTBEAT_INB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi3") { field(DESC, "Port BTM_RDB bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 3, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYH:858:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi3 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:PPSTRIPB") { field(DESC, "BTM-RT_DM60_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb3",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb3") #! Field("PLC:BSY0:PP04:BTM_RDBb3.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb3.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb3.FLNK","BTM:BSYH:858:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb3.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb3.VAL") #! Record("BTM:BSYH:858:PPSTRIPB_calc",260,18,0,1,"BTM:BSYH:858:PPSTRIPB_calc") #! Field("BTM:BSYH:858:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYH:858:PPSTRIPB_calc.INPA") #! Link("BTM:BSYH:858:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb3.VAL") #! Field("BTM:BSYH:858:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYH:858:PPSTRIPB_calc.INPB") #! Field("BTM:BSYH:858:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYH:858:PPSTRIPB_calc.OUT") #! Link("BTM:BSYH:858:PPSTRIPB_calc.OUT","BTM:BSYH:858:PPSTRIPB.VAL") #! Record("BTM:BSYH:858:PPSTRIPB",500,20,0,0,"BTM:BSYH:858:PPSTRIPB") #! Field("BTM:BSYH:858:PPSTRIPB.VAL",16777215,1,"BTM:BSYH:858:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi2") { field(DESC, "Port BTM_RDB bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:2:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:2:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:2:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:2:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb2",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb2") #! Field("PLC:BSY0:PP04:BTM_RDBb2.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb2.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb2.FLNK","BTM:BSY0:2:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb2.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb2.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:2:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:2:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:2:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:2:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb2.VAL") #! Field("BTM:BSY0:2:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:2:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:2:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:2:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:2:SPARE:PPSTRIPB") #! Field("BTM:BSY0:2:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi1") { field(DESC, "Port BTM_RDB bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:1240:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1240:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1240:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1240:PPSTRIPB") { field(DESC, "BTM-RT_DM12_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb1",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb1") #! Field("PLC:BSY0:PP04:BTM_RDBb1.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb1.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb1.FLNK","BTM:BSYA:1240:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb1.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb1.VAL") #! Record("BTM:BSYA:1240:PPSTRIPB_calc",260,18,0,1,"BTM:BSYA:1240:PPSTRIPB_calc") #! Field("BTM:BSYA:1240:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYA:1240:PPSTRIPB_calc.INPA") #! Link("BTM:BSYA:1240:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb1.VAL") #! Field("BTM:BSYA:1240:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYA:1240:PPSTRIPB_calc.INPB") #! Field("BTM:BSYA:1240:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYA:1240:PPSTRIPB_calc.OUT") #! Link("BTM:BSYA:1240:PPSTRIPB_calc.OUT","BTM:BSYA:1240:PPSTRIPB.VAL") #! Record("BTM:BSYA:1240:PPSTRIPB",500,20,0,0,"BTM:BSYA:1240:PPSTRIPB") #! Field("BTM:BSYA:1240:PPSTRIPB.VAL",16777215,1,"BTM:BSYA:1240:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi0") { field(DESC, "Port BTM_RDB bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 0, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:1490:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1490:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1490:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1490:PPSTRIPB") { field(DESC, "BTM-RT_DM14_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb0",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb0") #! Field("PLC:BSY0:PP04:BTM_RDBb0.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb0.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb0.FLNK","BTM:BSYA:1490:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb0.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb0.VAL") #! Record("BTM:BSYA:1490:PPSTRIPB_calc",260,18,0,1,"BTM:BSYA:1490:PPSTRIPB_calc") #! Field("BTM:BSYA:1490:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYA:1490:PPSTRIPB_calc.INPA") #! Link("BTM:BSYA:1490:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb0.VAL") #! Field("BTM:BSYA:1490:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYA:1490:PPSTRIPB_calc.INPB") #! Field("BTM:BSYA:1490:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYA:1490:PPSTRIPB_calc.OUT") #! Link("BTM:BSYA:1490:PPSTRIPB_calc.OUT","BTM:BSYA:1490:PPSTRIPB.VAL") #! Record("BTM:BSYA:1490:PPSTRIPB",500,20,0,0,"BTM:BSYA:1490:PPSTRIPB") #! Field("BTM:BSYA:1490:PPSTRIPB.VAL",16777215,1,"BTM:BSYA:1490:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi15") { field(DESC, "Port BTM_RDB bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:2275:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2275:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2275:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2275:PPSTRIPB") { field(DESC, "BTM-RT_DM22_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb15",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb15") #! Field("PLC:BSY0:PP04:BTM_RDBb15.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb15.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb15.FLNK","BTM:BSYA:2275:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb15.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb15.VAL") #! Record("BTM:BSYA:2275:PPSTRIPB_calc",260,18,0,1,"BTM:BSYA:2275:PPSTRIPB_calc") #! Field("BTM:BSYA:2275:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYA:2275:PPSTRIPB_calc.INPA") #! Link("BTM:BSYA:2275:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb15.VAL") #! Field("BTM:BSYA:2275:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYA:2275:PPSTRIPB_calc.INPB") #! Field("BTM:BSYA:2275:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYA:2275:PPSTRIPB_calc.OUT") #! Link("BTM:BSYA:2275:PPSTRIPB_calc.OUT","BTM:BSYA:2275:PPSTRIPB.VAL") #! Record("BTM:BSYA:2275:PPSTRIPB",500,20,0,0,"BTM:BSYA:2275:PPSTRIPB") #! Field("BTM:BSYA:2275:PPSTRIPB.VAL",16777215,1,"BTM:BSYA:2275:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi14") { field(DESC, "Port BTM_RDB bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYA:2930:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2930:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2930:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2930:PPSTRIPB") { field(DESC, "BTM-RT_DM29_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb14",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb14") #! Field("PLC:BSY0:PP04:BTM_RDBb14.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb14.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb14.FLNK","BTM:BSYA:2930:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb14.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb14.VAL") #! Record("BTM:BSYA:2930:PPSTRIPB_calc",260,18,0,1,"BTM:BSYA:2930:PPSTRIPB_calc") #! Field("BTM:BSYA:2930:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYA:2930:PPSTRIPB_calc.INPA") #! Link("BTM:BSYA:2930:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb14.VAL") #! Field("BTM:BSYA:2930:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYA:2930:PPSTRIPB_calc.INPB") #! Field("BTM:BSYA:2930:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYA:2930:PPSTRIPB_calc.OUT") #! Link("BTM:BSYA:2930:PPSTRIPB_calc.OUT","BTM:BSYA:2930:PPSTRIPB.VAL") #! Record("BTM:BSYA:2930:PPSTRIPB",500,20,0,0,"BTM:BSYA:2930:PPSTRIPB") #! Field("BTM:BSYA:2930:PPSTRIPB.VAL",16777215,1,"BTM:BSYA:2930:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi13") { field(DESC, "Port BTM_RDB bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 13, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYS:889:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:889:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:889:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:889:PPSTRIPB") { field(DESC, "BTM-RT_ST34A_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb13",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb13") #! Field("PLC:BSY0:PP04:BTM_RDBb13.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb13.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb13.FLNK","BTM:BSYS:889:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb13.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb13.VAL") #! Record("BTM:BSYS:889:PPSTRIPB_calc",260,18,0,1,"BTM:BSYS:889:PPSTRIPB_calc") #! Field("BTM:BSYS:889:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYS:889:PPSTRIPB_calc.INPA") #! Link("BTM:BSYS:889:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb13.VAL") #! Field("BTM:BSYS:889:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYS:889:PPSTRIPB_calc.INPB") #! Field("BTM:BSYS:889:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYS:889:PPSTRIPB_calc.OUT") #! Link("BTM:BSYS:889:PPSTRIPB_calc.OUT","BTM:BSYS:889:PPSTRIPB.VAL") #! Record("BTM:BSYS:889:PPSTRIPB",500,20,0,0,"BTM:BSYS:889:PPSTRIPB") #! Field("BTM:BSYS:889:PPSTRIPB.VAL",16777215,1,"BTM:BSYS:889:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi12") { field(DESC, "Port BTM_RDB bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSYS:898:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:898:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:898:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:898:PPSTRIPB") { field(DESC, "BTM-RT_ST34B_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb12",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb12") #! Field("PLC:BSY0:PP04:BTM_RDBb12.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb12.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb12.FLNK","BTM:BSYS:898:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb12.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb12.VAL") #! Record("BTM:BSYS:898:PPSTRIPB_calc",260,18,0,1,"BTM:BSYS:898:PPSTRIPB_calc") #! Field("BTM:BSYS:898:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSYS:898:PPSTRIPB_calc.INPA") #! Link("BTM:BSYS:898:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb12.VAL") #! Field("BTM:BSYS:898:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSYS:898:PPSTRIPB_calc.INPB") #! Field("BTM:BSYS:898:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSYS:898:PPSTRIPB_calc.OUT") #! Link("BTM:BSYS:898:PPSTRIPB_calc.OUT","BTM:BSYS:898:PPSTRIPB.VAL") #! Record("BTM:BSYS:898:PPSTRIPB",500,20,0,0,"BTM:BSYS:898:PPSTRIPB") #! Field("BTM:BSYS:898:PPSTRIPB.VAL",16777215,1,"BTM:BSYS:898:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi11") { field(DESC, "Port BTM_RDB bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:CLTS:585:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:CLTS:585:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi11 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:CLTS:585:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:CLTS:585:PPSTRIPB") { field(DESC, "BTM-RT_STCLTS_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb11",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb11") #! Field("PLC:BSY0:PP04:BTM_RDBb11.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb11.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb11.FLNK","BTM:CLTS:585:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb11.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb11.VAL") #! Record("BTM:CLTS:585:PPSTRIPB_calc",260,18,0,1,"BTM:CLTS:585:PPSTRIPB_calc") #! Field("BTM:CLTS:585:PPSTRIPB_calc.INPA",16777215,0,"BTM:CLTS:585:PPSTRIPB_calc.INPA") #! Link("BTM:CLTS:585:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb11.VAL") #! Field("BTM:CLTS:585:PPSTRIPB_calc.INPB",16777215,1,"BTM:CLTS:585:PPSTRIPB_calc.INPB") #! Field("BTM:CLTS:585:PPSTRIPB_calc.OUT",16777215,1,"BTM:CLTS:585:PPSTRIPB_calc.OUT") #! Link("BTM:CLTS:585:PPSTRIPB_calc.OUT","BTM:CLTS:585:PPSTRIPB.VAL") #! Record("BTM:CLTS:585:PPSTRIPB",500,20,0,0,"BTM:CLTS:585:PPSTRIPB") #! Field("BTM:CLTS:585:PPSTRIPB.VAL",16777215,1,"BTM:CLTS:585:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi10") { field(DESC, "Port BTM_RDB bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 10, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:10:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:10:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:10:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:10:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb10",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb10") #! Field("PLC:BSY0:PP04:BTM_RDBb10.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb10.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb10.FLNK","BTM:BSY0:10:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb10.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb10.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:10:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:10:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:10:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:10:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb10.VAL") #! Field("BTM:BSY0:10:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:10:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:10:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:10:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:10:SPARE:PPSTRIPB") #! Field("BTM:BSY0:10:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi9") { field(DESC, "Port BTM_RDB bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:11:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:11:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:11:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:11:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb9",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb9") #! Field("PLC:BSY0:PP04:BTM_RDBb9.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb9.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb9.FLNK","BTM:BSY0:11:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb9.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb9.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:11:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:11:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:11:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:11:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb9.VAL") #! Field("BTM:BSY0:11:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:11:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:11:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:11:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:11:SPARE:PPSTRIPB") #! Field("BTM:BSY0:11:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi8") { field(DESC, "Port BTM_RDB bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 8, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:12:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:12:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:12:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:12:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb8",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb8") #! Field("PLC:BSY0:PP04:BTM_RDBb8.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb8.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb8.FLNK","BTM:BSY0:12:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb8.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb8.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:12:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:12:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:12:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:12:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb8.VAL") #! Field("BTM:BSY0:12:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:12:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:12:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:12:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:12:SPARE:PPSTRIPB") #! Field("BTM:BSY0:12:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi23") { field(DESC, "Port BTM_RDB bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:13:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:13:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:13:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:13:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb23",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb23") #! Field("PLC:BSY0:PP04:BTM_RDBb23.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb23.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb23.FLNK","BTM:BSY0:13:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb23.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb23.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:13:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:13:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:13:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:13:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb23.VAL") #! Field("BTM:BSY0:13:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:13:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:13:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:13:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:13:SPARE:PPSTRIPB") #! Field("BTM:BSY0:13:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi22") { field(DESC, "Port BTM_RDB bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 22, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:14:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:14:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:14:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:14:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb22",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb22") #! Field("PLC:BSY0:PP04:BTM_RDBb22.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb22.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb22.FLNK","BTM:BSY0:14:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb22.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb22.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:14:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:14:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:14:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:14:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb22.VAL") #! Field("BTM:BSY0:14:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:14:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:14:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:14:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:14:SPARE:PPSTRIPB") #! Field("BTM:BSY0:14:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi21") { field(DESC, "Port BTM_RDB bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:15:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:15:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:15:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:15:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb21",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb21") #! Field("PLC:BSY0:PP04:BTM_RDBb21.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb21.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb21.FLNK","BTM:BSY0:15:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb21.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb21.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:15:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:15:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:15:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:15:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb21.VAL") #! Field("BTM:BSY0:15:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:15:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:15:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:15:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:15:SPARE:PPSTRIPB") #! Field("BTM:BSY0:15:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi20") { field(DESC, "Port BTM_RDB bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:16:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:16:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:16:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:16:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb20",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb20") #! Field("PLC:BSY0:PP04:BTM_RDBb20.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb20.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb20.FLNK","BTM:BSY0:16:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb20.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb20.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:16:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:16:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:16:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:16:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb20.VAL") #! Field("BTM:BSY0:16:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:16:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:16:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:16:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:16:SPARE:PPSTRIPB") #! Field("BTM:BSY0:16:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi94") { field(DESC, "Port BTM_RDB bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 94, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:17:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:17:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi94 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:17:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:17:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb94",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb94") #! Field("PLC:BSY0:PP04:BTM_RDBb94.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb94.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb94.FLNK","BTM:BSY0:17:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb94.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb94.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:17:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:17:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:17:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:17:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb94.VAL") #! Field("BTM:BSY0:17:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:17:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:17:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:17:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:17:SPARE:PPSTRIPB") #! Field("BTM:BSY0:17:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi93") { field(DESC, "Port BTM_RDB bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:18:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:18:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi93 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:18:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:18:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb93",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb93") #! Field("PLC:BSY0:PP04:BTM_RDBb93.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb93.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb93.FLNK","BTM:BSY0:18:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb93.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb93.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:18:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:18:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:18:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:18:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb93.VAL") #! Field("BTM:BSY0:18:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:18:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:18:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:18:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:18:SPARE:PPSTRIPB") #! Field("BTM:BSY0:18:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi92") { field(DESC, "Port BTM_RDB bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:19:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:19:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi92 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:19:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:19:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb92",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb92") #! Field("PLC:BSY0:PP04:BTM_RDBb92.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb92.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb92.FLNK","BTM:BSY0:19:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb92.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb92.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:19:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:19:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:19:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:19:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb92.VAL") #! Field("BTM:BSY0:19:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:19:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:19:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:19:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:19:SPARE:PPSTRIPB") #! Field("BTM:BSY0:19:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi91") { field(DESC, "Port BTM_RDB bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:20:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:20:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi91 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:20:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:20:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb91",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb91") #! Field("PLC:BSY0:PP04:BTM_RDBb91.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb91.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb91.FLNK","BTM:BSY0:20:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb91.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb91.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:20:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:20:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:20:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:20:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb91.VAL") #! Field("BTM:BSY0:20:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:20:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:20:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:20:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:20:SPARE:PPSTRIPB") #! Field("BTM:BSY0:20:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi90") { field(DESC, "Port BTM_RDB bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:21:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:21:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:21:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:21:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb90",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb90") #! Field("PLC:BSY0:PP04:BTM_RDBb90.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb90.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb90.FLNK","BTM:BSY0:21:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb90.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb90.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:21:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:21:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:21:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:21:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb90.VAL") #! Field("BTM:BSY0:21:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:21:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:21:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:21:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:21:SPARE:PPSTRIPB") #! Field("BTM:BSY0:21:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi89") { field(DESC, "Port BTM_RDB bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:22:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:22:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:22:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:22:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb89",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb89") #! Field("PLC:BSY0:PP04:BTM_RDBb89.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb89.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb89.FLNK","BTM:BSY0:22:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb89.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb89.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:22:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:22:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:22:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:22:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb89.VAL") #! Field("BTM:BSY0:22:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:22:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:22:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:22:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:22:SPARE:PPSTRIPB") #! Field("BTM:BSY0:22:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi88") { field(DESC, "Port BTM_RDB bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:23:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:23:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:23:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:23:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb88",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb88") #! Field("PLC:BSY0:PP04:BTM_RDBb88.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb88.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb88.FLNK","BTM:BSY0:23:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb88.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb88.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:23:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:23:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:23:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:23:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb88.VAL") #! Field("BTM:BSY0:23:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:23:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:23:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:23:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:23:SPARE:PPSTRIPB") #! Field("BTM:BSY0:23:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi103") { field(DESC, "Port BTM_RDB bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:24:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:24:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:24:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:24:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb103",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb103") #! Field("PLC:BSY0:PP04:BTM_RDBb103.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb103.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb103.FLNK","BTM:BSY0:24:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb103.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb103.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:24:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:24:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:24:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:24:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb103.VAL") #! Field("BTM:BSY0:24:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:24:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:24:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:24:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:24:SPARE:PPSTRIPB") #! Field("BTM:BSY0:24:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi102") { field(DESC, "Port BTM_RDB bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:25:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:25:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:25:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:25:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb102",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb102") #! Field("PLC:BSY0:PP04:BTM_RDBb102.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb102.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb102.FLNK","BTM:BSY0:25:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb102.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb102.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:25:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:25:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:25:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:25:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb102.VAL") #! Field("BTM:BSY0:25:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:25:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:25:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:25:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:25:SPARE:PPSTRIPB") #! Field("BTM:BSY0:25:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi101") { field(DESC, "Port BTM_RDB bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:26:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:26:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:26:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:26:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb101",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb101") #! Field("PLC:BSY0:PP04:BTM_RDBb101.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb101.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb101.FLNK","BTM:BSY0:26:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb101.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb101.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:26:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:26:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:26:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:26:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb101.VAL") #! Field("BTM:BSY0:26:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:26:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:26:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:26:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:26:SPARE:PPSTRIPB") #! Field("BTM:BSY0:26:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi100") { field(DESC, "Port BTM_RDB bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:27:SPARE:PPSTRIPB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:27:SPARE:PPSTRIPB_calc") { field(INPA, "PLC:BSY0:PP04:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:27:SPARE:PPSTRIPB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:27:SPARE:PPSTRIPB") { field(DESC, "BTM-RT_SPARE_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb100",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb100") #! Field("PLC:BSY0:PP04:BTM_RDBb100.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb100.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb100.FLNK","BTM:BSY0:27:SPARE:PPSTRIPB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb100.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb100.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPB_calc",260,18,0,1,"BTM:BSY0:27:SPARE:PPSTRIPB_calc") #! Field("BTM:BSY0:27:SPARE:PPSTRIPB_calc.INPA",16777215,0,"BTM:BSY0:27:SPARE:PPSTRIPB_calc.INPA") #! Link("BTM:BSY0:27:SPARE:PPSTRIPB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb100.VAL") #! Field("BTM:BSY0:27:SPARE:PPSTRIPB_calc.INPB",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPB_calc.INPB") #! Field("BTM:BSY0:27:SPARE:PPSTRIPB_calc.OUT",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPB_calc.OUT") #! Link("BTM:BSY0:27:SPARE:PPSTRIPB_calc.OUT","BTM:BSY0:27:SPARE:PPSTRIPB.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPB",500,20,0,0,"BTM:BSY0:27:SPARE:PPSTRIPB") #! Field("BTM:BSY0:27:SPARE:PPSTRIPB.VAL",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi110") { field(DESC, "Port BTM_RDB bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc") { field(INPA, "PLC:BSY0:PP04:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SS0_HEARTBEAT_OUTB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SS0_HEARTBEAT_OUTB") { field(DESC, "BTM-SS0_Heartbeat_Out_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb110",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb110") #! Field("PLC:BSY0:PP04:BTM_RDBb110.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb110.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb110.FLNK","BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb110.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb110.VAL") #! Record("BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc",260,18,0,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.INPA",16777215,0,"BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.INPA") #! Link("BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb110.VAL") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.INPB",16777215,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.INPB") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.OUT",16777215,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.OUT") #! Link("BTM:BSY0:1:SS0_HEARTBEAT_OUTB_calc.OUT","BTM:BSY0:1:SS0_HEARTBEAT_OUTB.VAL") #! Record("BTM:BSY0:1:SS0_HEARTBEAT_OUTB",500,20,0,0,"BTM:BSY0:1:SS0_HEARTBEAT_OUTB") #! Field("BTM:BSY0:1:SS0_HEARTBEAT_OUTB.VAL",16777215,1,"BTM:BSY0:1:SS0_HEARTBEAT_OUTB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi108") { field(DESC, "Port BTM_RDB bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 108, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB") { field(DESC, "BTM-SS2_Heartbeat_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb108",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb108") #! Field("PLC:BSY0:PP04:BTM_RDBb108.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb108.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb108.FLNK","BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb108.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb108.VAL") #! Record("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc",260,18,0,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.INPA",16777215,0,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.INPA") #! Link("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb108.VAL") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.INPB",16777215,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.INPB") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.OUT",16777215,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.OUT") #! Link("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB_calc.OUT","BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB.VAL") #! Record("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB",500,20,0,0,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB") #! Field("BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB.VAL",16777215,1,"BTM:BSY0:1:SS2_HEARTBEAT_OKLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi107") { field(DESC, "Port BTM_RDB bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SS3_SPAREB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SS3_SPAREB_calc") { field(INPA, "PLC:BSY0:PP04:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SS3_SPAREB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SS3_SPAREB") { field(DESC, "BTM-SS3_Spare_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb107",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb107") #! Field("PLC:BSY0:PP04:BTM_RDBb107.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb107.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb107.FLNK","BTM:BSY0:1:SS3_SPAREB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb107.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb107.VAL") #! Record("BTM:BSY0:1:SS3_SPAREB_calc",260,18,0,1,"BTM:BSY0:1:SS3_SPAREB_calc") #! Field("BTM:BSY0:1:SS3_SPAREB_calc.INPA",16777215,0,"BTM:BSY0:1:SS3_SPAREB_calc.INPA") #! Link("BTM:BSY0:1:SS3_SPAREB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb107.VAL") #! Field("BTM:BSY0:1:SS3_SPAREB_calc.INPB",16777215,1,"BTM:BSY0:1:SS3_SPAREB_calc.INPB") #! Field("BTM:BSY0:1:SS3_SPAREB_calc.OUT",16777215,1,"BTM:BSY0:1:SS3_SPAREB_calc.OUT") #! Link("BTM:BSY0:1:SS3_SPAREB_calc.OUT","BTM:BSY0:1:SS3_SPAREB.VAL") #! Record("BTM:BSY0:1:SS3_SPAREB",500,20,0,0,"BTM:BSY0:1:SS3_SPAREB") #! Field("BTM:BSY0:1:SS3_SPAREB.VAL",16777215,1,"BTM:BSY0:1:SS3_SPAREB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi106") { field(DESC, "Port BTM_RDB bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 106, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:INTLK_OK_SUM_LTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:INTLK_OK_SUM_LTHB") { field(DESC, "BTM-Intlk_Ok_Lat_Summary_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb106",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb106") #! Field("PLC:BSY0:PP04:BTM_RDBb106.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb106.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb106.FLNK","BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb106.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb106.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc",260,18,0,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.INPA",16777215,0,"BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.INPA") #! Link("BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb106.VAL") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.INPB",16777215,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.INPB") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.OUT",16777215,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.OUT") #! Link("BTM:BSY0:1:INTLK_OK_SUM_LTHB_calc.OUT","BTM:BSY0:1:INTLK_OK_SUM_LTHB.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUM_LTHB",500,20,0,0,"BTM:BSY0:1:INTLK_OK_SUM_LTHB") #! Field("BTM:BSY0:1:INTLK_OK_SUM_LTHB.VAL",16777215,1,"BTM:BSY0:1:INTLK_OK_SUM_LTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi105") { field(DESC, "Port BTM_RDB bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 105, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:INTLK_OK_SUMB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:INTLK_OK_SUMB_calc") { field(INPA, "PLC:BSY0:PP04:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:INTLK_OK_SUMB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:INTLK_OK_SUMB") { field(DESC, "BTM-Intlk_Ok_RT_Summary_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb105",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb105") #! Field("PLC:BSY0:PP04:BTM_RDBb105.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb105.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb105.FLNK","BTM:BSY0:1:INTLK_OK_SUMB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb105.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb105.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUMB_calc",260,18,0,1,"BTM:BSY0:1:INTLK_OK_SUMB_calc") #! Field("BTM:BSY0:1:INTLK_OK_SUMB_calc.INPA",16777215,0,"BTM:BSY0:1:INTLK_OK_SUMB_calc.INPA") #! Link("BTM:BSY0:1:INTLK_OK_SUMB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb105.VAL") #! Field("BTM:BSY0:1:INTLK_OK_SUMB_calc.INPB",16777215,1,"BTM:BSY0:1:INTLK_OK_SUMB_calc.INPB") #! Field("BTM:BSY0:1:INTLK_OK_SUMB_calc.OUT",16777215,1,"BTM:BSY0:1:INTLK_OK_SUMB_calc.OUT") #! Link("BTM:BSY0:1:INTLK_OK_SUMB_calc.OUT","BTM:BSY0:1:INTLK_OK_SUMB.VAL") #! Record("BTM:BSY0:1:INTLK_OK_SUMB",500,20,0,0,"BTM:BSY0:1:INTLK_OK_SUMB") #! Field("BTM:BSY0:1:INTLK_OK_SUMB.VAL",16777215,1,"BTM:BSY0:1:INTLK_OK_SUMB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi104") { field(DESC, "Port BTM_RDB bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 104, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:RO3_SPAREB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:RO3_SPAREB_calc") { field(INPA, "PLC:BSY0:PP04:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:RO3_SPAREB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:RO3_SPAREB") { field(DESC, "BTM-Relay_Output_3_Spare_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb104",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb104") #! Field("PLC:BSY0:PP04:BTM_RDBb104.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb104.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb104.FLNK","BTM:BSY0:1:RO3_SPAREB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb104.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb104.VAL") #! Record("BTM:BSY0:1:RO3_SPAREB_calc",260,18,0,1,"BTM:BSY0:1:RO3_SPAREB_calc") #! Field("BTM:BSY0:1:RO3_SPAREB_calc.INPA",16777215,0,"BTM:BSY0:1:RO3_SPAREB_calc.INPA") #! Link("BTM:BSY0:1:RO3_SPAREB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb104.VAL") #! Field("BTM:BSY0:1:RO3_SPAREB_calc.INPB",16777215,1,"BTM:BSY0:1:RO3_SPAREB_calc.INPB") #! Field("BTM:BSY0:1:RO3_SPAREB_calc.OUT",16777215,1,"BTM:BSY0:1:RO3_SPAREB_calc.OUT") #! Link("BTM:BSY0:1:RO3_SPAREB_calc.OUT","BTM:BSY0:1:RO3_SPAREB.VAL") #! Record("BTM:BSY0:1:RO3_SPAREB",500,20,0,0,"BTM:BSY0:1:RO3_SPAREB") #! Field("BTM:BSY0:1:RO3_SPAREB.VAL",16777215,1,"BTM:BSY0:1:RO3_SPAREB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi119") { field(DESC, "Port BTM_RDB bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 119, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:RO4_SPAREB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:RO4_SPAREB_calc") { field(INPA, "PLC:BSY0:PP04:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:RO4_SPAREB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:RO4_SPAREB") { field(DESC, "BTM-Relay_Output_4_Spare_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb119",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb119") #! Field("PLC:BSY0:PP04:BTM_RDBb119.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb119.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb119.FLNK","BTM:BSY0:1:RO4_SPAREB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb119.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb119.VAL") #! Record("BTM:BSY0:1:RO4_SPAREB_calc",260,18,0,1,"BTM:BSY0:1:RO4_SPAREB_calc") #! Field("BTM:BSY0:1:RO4_SPAREB_calc.INPA",16777215,0,"BTM:BSY0:1:RO4_SPAREB_calc.INPA") #! Link("BTM:BSY0:1:RO4_SPAREB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb119.VAL") #! Field("BTM:BSY0:1:RO4_SPAREB_calc.INPB",16777215,1,"BTM:BSY0:1:RO4_SPAREB_calc.INPB") #! Field("BTM:BSY0:1:RO4_SPAREB_calc.OUT",16777215,1,"BTM:BSY0:1:RO4_SPAREB_calc.OUT") #! Link("BTM:BSY0:1:RO4_SPAREB_calc.OUT","BTM:BSY0:1:RO4_SPAREB.VAL") #! Record("BTM:BSY0:1:RO4_SPAREB",500,20,0,0,"BTM:BSY0:1:RO4_SPAREB") #! Field("BTM:BSY0:1:RO4_SPAREB.VAL",16777215,1,"BTM:BSY0:1:RO4_SPAREB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi116") { field(DESC, "Port BTM_RDB bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYH:858:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:PPSTRIPLTHB") { field(DESC, "BTM-DM60_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb116",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb116") #! Field("PLC:BSY0:PP04:BTM_RDBb116.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb116.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb116.FLNK","BTM:BSYH:858:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb116.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb116.VAL") #! Record("BTM:BSYH:858:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYH:858:PPSTRIPLTHB_calc") #! Field("BTM:BSYH:858:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYH:858:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYH:858:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb116.VAL") #! Field("BTM:BSYH:858:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYH:858:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYH:858:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYH:858:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYH:858:PPSTRIPLTHB_calc.OUT","BTM:BSYH:858:PPSTRIPLTHB.VAL") #! Record("BTM:BSYH:858:PPSTRIPLTHB",500,20,0,0,"BTM:BSYH:858:PPSTRIPLTHB") #! Field("BTM:BSYH:858:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYH:858:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi115") { field(DESC, "Port BTM_RDB bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:2:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:2:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb115",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb115") #! Field("PLC:BSY0:PP04:BTM_RDBb115.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb115.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb115.FLNK","BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb115.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb115.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb115.VAL") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:2:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:2:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:2:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:2:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:2:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:2:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi114") { field(DESC, "Port BTM_RDB bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:1240:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1240:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1240:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1240:PPSTRIPLTHB") { field(DESC, "BTM-DM12_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb114",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb114") #! Field("PLC:BSY0:PP04:BTM_RDBb114.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb114.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb114.FLNK","BTM:BSYA:1240:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb114.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb114.VAL") #! Record("BTM:BSYA:1240:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYA:1240:PPSTRIPLTHB_calc") #! Field("BTM:BSYA:1240:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYA:1240:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYA:1240:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb114.VAL") #! Field("BTM:BSYA:1240:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYA:1240:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYA:1240:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYA:1240:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYA:1240:PPSTRIPLTHB_calc.OUT","BTM:BSYA:1240:PPSTRIPLTHB.VAL") #! Record("BTM:BSYA:1240:PPSTRIPLTHB",500,20,0,0,"BTM:BSYA:1240:PPSTRIPLTHB") #! Field("BTM:BSYA:1240:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYA:1240:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi113") { field(DESC, "Port BTM_RDB bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:1490:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:1490:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:1490:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:1490:PPSTRIPLTHB") { field(DESC, "BTM-DM14_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb113",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb113") #! Field("PLC:BSY0:PP04:BTM_RDBb113.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb113.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb113.FLNK","BTM:BSYA:1490:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb113.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb113.VAL") #! Record("BTM:BSYA:1490:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYA:1490:PPSTRIPLTHB_calc") #! Field("BTM:BSYA:1490:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYA:1490:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYA:1490:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb113.VAL") #! Field("BTM:BSYA:1490:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYA:1490:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYA:1490:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYA:1490:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYA:1490:PPSTRIPLTHB_calc.OUT","BTM:BSYA:1490:PPSTRIPLTHB.VAL") #! Record("BTM:BSYA:1490:PPSTRIPLTHB",500,20,0,0,"BTM:BSYA:1490:PPSTRIPLTHB") #! Field("BTM:BSYA:1490:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYA:1490:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi112") { field(DESC, "Port BTM_RDB bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 112, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:2275:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2275:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi112 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2275:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2275:PPSTRIPLTHB") { field(DESC, "BTM-DM22_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb112",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb112") #! Field("PLC:BSY0:PP04:BTM_RDBb112.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb112.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb112.FLNK","BTM:BSYA:2275:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb112.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb112.VAL") #! Record("BTM:BSYA:2275:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYA:2275:PPSTRIPLTHB_calc") #! Field("BTM:BSYA:2275:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYA:2275:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYA:2275:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb112.VAL") #! Field("BTM:BSYA:2275:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYA:2275:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYA:2275:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYA:2275:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYA:2275:PPSTRIPLTHB_calc.OUT","BTM:BSYA:2275:PPSTRIPLTHB.VAL") #! Record("BTM:BSYA:2275:PPSTRIPLTHB",500,20,0,0,"BTM:BSYA:2275:PPSTRIPLTHB") #! Field("BTM:BSYA:2275:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYA:2275:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi127") { field(DESC, "Port BTM_RDB bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 127, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYA:2930:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYA:2930:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYA:2930:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYA:2930:PPSTRIPLTHB") { field(DESC, "BTM-DM29_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb127",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb127") #! Field("PLC:BSY0:PP04:BTM_RDBb127.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb127.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb127.FLNK","BTM:BSYA:2930:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb127.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb127.VAL") #! Record("BTM:BSYA:2930:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYA:2930:PPSTRIPLTHB_calc") #! Field("BTM:BSYA:2930:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYA:2930:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYA:2930:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb127.VAL") #! Field("BTM:BSYA:2930:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYA:2930:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYA:2930:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYA:2930:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYA:2930:PPSTRIPLTHB_calc.OUT","BTM:BSYA:2930:PPSTRIPLTHB.VAL") #! Record("BTM:BSYA:2930:PPSTRIPLTHB",500,20,0,0,"BTM:BSYA:2930:PPSTRIPLTHB") #! Field("BTM:BSYA:2930:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYA:2930:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi126") { field(DESC, "Port BTM_RDB bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 126, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYS:889:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:889:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi126 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:889:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:889:PPSTRIPLTHB") { field(DESC, "BTM-ST34A_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb126",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb126") #! Field("PLC:BSY0:PP04:BTM_RDBb126.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb126.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb126.FLNK","BTM:BSYS:889:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb126.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb126.VAL") #! Record("BTM:BSYS:889:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYS:889:PPSTRIPLTHB_calc") #! Field("BTM:BSYS:889:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYS:889:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYS:889:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb126.VAL") #! Field("BTM:BSYS:889:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYS:889:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYS:889:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYS:889:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYS:889:PPSTRIPLTHB_calc.OUT","BTM:BSYS:889:PPSTRIPLTHB.VAL") #! Record("BTM:BSYS:889:PPSTRIPLTHB",500,20,0,0,"BTM:BSYS:889:PPSTRIPLTHB") #! Field("BTM:BSYS:889:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYS:889:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi125") { field(DESC, "Port BTM_RDB bit 125") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 125, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSYS:898:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYS:898:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi125 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYS:898:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYS:898:PPSTRIPLTHB") { field(DESC, "BTM-ST34B_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb125",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb125") #! Field("PLC:BSY0:PP04:BTM_RDBb125.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb125.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb125.FLNK","BTM:BSYS:898:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb125.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb125.VAL") #! Record("BTM:BSYS:898:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSYS:898:PPSTRIPLTHB_calc") #! Field("BTM:BSYS:898:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSYS:898:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSYS:898:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb125.VAL") #! Field("BTM:BSYS:898:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSYS:898:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSYS:898:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSYS:898:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSYS:898:PPSTRIPLTHB_calc.OUT","BTM:BSYS:898:PPSTRIPLTHB.VAL") #! Record("BTM:BSYS:898:PPSTRIPLTHB",500,20,0,0,"BTM:BSYS:898:PPSTRIPLTHB") #! Field("BTM:BSYS:898:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSYS:898:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi124") { field(DESC, "Port BTM_RDB bit 124") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 124, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:CLTS:585:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:CLTS:585:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi124 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:CLTS:585:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:CLTS:585:PPSTRIPLTHB") { field(DESC, "BTM-STCLTS_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb124",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb124") #! Field("PLC:BSY0:PP04:BTM_RDBb124.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb124.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb124.FLNK","BTM:CLTS:585:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb124.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb124.VAL") #! Record("BTM:CLTS:585:PPSTRIPLTHB_calc",260,18,0,1,"BTM:CLTS:585:PPSTRIPLTHB_calc") #! Field("BTM:CLTS:585:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:CLTS:585:PPSTRIPLTHB_calc.INPA") #! Link("BTM:CLTS:585:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb124.VAL") #! Field("BTM:CLTS:585:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:CLTS:585:PPSTRIPLTHB_calc.INPB") #! Field("BTM:CLTS:585:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:CLTS:585:PPSTRIPLTHB_calc.OUT") #! Link("BTM:CLTS:585:PPSTRIPLTHB_calc.OUT","BTM:CLTS:585:PPSTRIPLTHB.VAL") #! Record("BTM:CLTS:585:PPSTRIPLTHB",500,20,0,0,"BTM:CLTS:585:PPSTRIPLTHB") #! Field("BTM:CLTS:585:PPSTRIPLTHB.VAL",16777215,1,"BTM:CLTS:585:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi123") { field(DESC, "Port BTM_RDB bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 123, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:10:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:10:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb123",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb123") #! Field("PLC:BSY0:PP04:BTM_RDBb123.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb123.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb123.FLNK","BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb123.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb123.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb123.VAL") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:10:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:10:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:10:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:10:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:10:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:10:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi122") { field(DESC, "Port BTM_RDB bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 122, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi122 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:11:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:11:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb122",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb122") #! Field("PLC:BSY0:PP04:BTM_RDBb122.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb122.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb122.FLNK","BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb122.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb122.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb122.VAL") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:11:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:11:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:11:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:11:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:11:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:11:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi121") { field(DESC, "Port BTM_RDB bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 121, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:12:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:12:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb121",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb121") #! Field("PLC:BSY0:PP04:BTM_RDBb121.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb121.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb121.FLNK","BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb121.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb121.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb121.VAL") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:12:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:12:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:12:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:12:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:12:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:12:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi120") { field(DESC, "Port BTM_RDB bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 120, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:13:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:13:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb120",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb120") #! Field("PLC:BSY0:PP04:BTM_RDBb120.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb120.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb120.FLNK","BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb120.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb120.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb120.VAL") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:13:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:13:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:13:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:13:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:13:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:13:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi135") { field(DESC, "Port BTM_RDB bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 135, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:14:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:14:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb135",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb135") #! Field("PLC:BSY0:PP04:BTM_RDBb135.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb135.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb135.FLNK","BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb135.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb135.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb135.VAL") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:14:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:14:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:14:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:14:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:14:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:14:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi134") { field(DESC, "Port BTM_RDB bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 134, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:15:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:15:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb134",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb134") #! Field("PLC:BSY0:PP04:BTM_RDBb134.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb134.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb134.FLNK","BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb134.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb134.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb134.VAL") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:15:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:15:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:15:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:15:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:15:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:15:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi133") { field(DESC, "Port BTM_RDB bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 133, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:16:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:16:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb133",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb133") #! Field("PLC:BSY0:PP04:BTM_RDBb133.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb133.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb133.FLNK","BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb133.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb133.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb133.VAL") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:16:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:16:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:16:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:16:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:16:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:16:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi132") { field(DESC, "Port BTM_RDB bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 132, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:17:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:17:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb132",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb132") #! Field("PLC:BSY0:PP04:BTM_RDBb132.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb132.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb132.FLNK","BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb132.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb132.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb132.VAL") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:17:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:17:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:17:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:17:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:17:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:17:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi131") { field(DESC, "Port BTM_RDB bit 131") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 131, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi131 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:18:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:18:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb131",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb131") #! Field("PLC:BSY0:PP04:BTM_RDBb131.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb131.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb131.FLNK","BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb131.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb131.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb131.VAL") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:18:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:18:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:18:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:18:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:18:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:18:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi130") { field(DESC, "Port BTM_RDB bit 130") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 130, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi130 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:19:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:19:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb130",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb130") #! Field("PLC:BSY0:PP04:BTM_RDBb130.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb130.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb130.FLNK","BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb130.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb130.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb130.VAL") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:19:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:19:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:19:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:19:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:19:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:19:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi129") { field(DESC, "Port BTM_RDB bit 129") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 129, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi129 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:20:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:20:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb129",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb129") #! Field("PLC:BSY0:PP04:BTM_RDBb129.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb129.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb129.FLNK","BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb129.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb129.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb129.VAL") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:20:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:20:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:20:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:20:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:20:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:20:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi128") { field(DESC, "Port BTM_RDB bit 128") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 128, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi128 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:21:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:21:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb128",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb128") #! Field("PLC:BSY0:PP04:BTM_RDBb128.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb128.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb128.FLNK","BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb128.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb128.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb128.VAL") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:21:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:21:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:21:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:21:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:21:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:21:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi143") { field(DESC, "Port BTM_RDB bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 143, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:22:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:22:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb143",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb143") #! Field("PLC:BSY0:PP04:BTM_RDBb143.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb143.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb143.FLNK","BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb143.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb143.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb143.VAL") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:22:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:22:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:22:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:22:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:22:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:22:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi142") { field(DESC, "Port BTM_RDB bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 142, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:23:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:23:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb142",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb142") #! Field("PLC:BSY0:PP04:BTM_RDBb142.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb142.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb142.FLNK","BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb142.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb142.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb142.VAL") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:23:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:23:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:23:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:23:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:23:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:23:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi141") { field(DESC, "Port BTM_RDB bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 141, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:24:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:24:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb141",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb141") #! Field("PLC:BSY0:PP04:BTM_RDBb141.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb141.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb141.FLNK","BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb141.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb141.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb141.VAL") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:24:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:24:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:24:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:24:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:24:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:24:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi140") { field(DESC, "Port BTM_RDB bit 140") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 140, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi140 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:25:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:25:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb140",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb140") #! Field("PLC:BSY0:PP04:BTM_RDBb140.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb140.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb140.FLNK","BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb140.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb140.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb140.VAL") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:25:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:25:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:25:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:25:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:25:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:25:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi139") { field(DESC, "Port BTM_RDB bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 139, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:26:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:26:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb139",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb139") #! Field("PLC:BSY0:PP04:BTM_RDBb139.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb139.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb139.FLNK","BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb139.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb139.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb139.VAL") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:26:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:26:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:26:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:26:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:26:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:26:SPARE:PPSTRIPLTHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP04:Bi138") { field(DESC, "Port BTM_RDB bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc") { field(INPA, "PLC:BSY0:PP04:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP04:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:27:SPARE:PPSTRIPLTHB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:27:SPARE:PPSTRIPLTHB") { field(DESC, "BTM-SPARE_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP04:BTM_RDBb138",20,19,0,0,"PLC:BSY0:PP04:BTM_RDBb138") #! Field("PLC:BSY0:PP04:BTM_RDBb138.FLNK",16777215,1,"PLC:BSY0:PP04:BTM_RDBb138.FLNK") #! Link("PLC:BSY0:PP04:BTM_RDBb138.FLNK","BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc") #! Field("PLC:BSY0:PP04:BTM_RDBb138.VAL",16777215,0,"PLC:BSY0:PP04:BTM_RDBb138.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc",260,18,0,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.INPA",16777215,0,"BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.INPA") #! Link("BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.INPA","PLC:BSY0:PP04:BTM_RDBb138.VAL") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.INPB",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.INPB") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.OUT",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.OUT") #! Link("BTM:BSY0:27:SPARE:PPSTRIPLTHB_calc.OUT","BTM:BSY0:27:SPARE:PPSTRIPLTHB.VAL") #! Record("BTM:BSY0:27:SPARE:PPSTRIPLTHB",500,20,0,0,"BTM:BSY0:27:SPARE:PPSTRIPLTHB") #! Field("BTM:BSY0:27:SPARE:PPSTRIPLTHB.VAL",16777215,1,"BTM:BSY0:27:SPARE:PPSTRIPLTHB.VAL") record(calc, "BTM:BSY0:1:HARDWIRE_INTLK_RESETCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:1:HARDWIRE_INTLK_RESET") field(CALC, "A&&B") field(INPA, "BTM:BSY0:1:HARDWIRE_INTLK_RESETA MS") field(INPB, "BTM:BSY0:1:HARDWIRE_INTLK_RESETB MS") } record(bi, "BTM:BSY0:1:HARDWIRE_INTLK_RESET") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(INP, "BTM:BSY0:1:HARDWIRE_INTLK_RESETCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYH:858:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYH:858:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYH:858:PPSTRIPA MS") field(INPB, "BTM:BSYH:858:PPSTRIPB MS") } record(bi, "BTM:BSYH:858:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYH:858:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:2:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:2:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:2:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:2:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:2:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:2:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:1240:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:1240:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYA:1240:PPSTRIPA MS") field(INPB, "BTM:BSYA:1240:PPSTRIPB MS") } record(bi, "BTM:BSYA:1240:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYA:1240:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:1490:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:1490:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYA:1490:PPSTRIPA MS") field(INPB, "BTM:BSYA:1490:PPSTRIPB MS") } record(bi, "BTM:BSYA:1490:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYA:1490:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:2275:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:2275:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYA:2275:PPSTRIPA MS") field(INPB, "BTM:BSYA:2275:PPSTRIPB MS") } record(bi, "BTM:BSYA:2275:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYA:2275:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:2930:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:2930:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYA:2930:PPSTRIPA MS") field(INPB, "BTM:BSYA:2930:PPSTRIPB MS") } record(bi, "BTM:BSYA:2930:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYA:2930:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYS:889:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYS:889:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYS:889:PPSTRIPA MS") field(INPB, "BTM:BSYS:889:PPSTRIPB MS") } record(bi, "BTM:BSYS:889:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYS:889:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYS:898:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYS:898:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSYS:898:PPSTRIPA MS") field(INPB, "BTM:BSYS:898:PPSTRIPB MS") } record(bi, "BTM:BSYS:898:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSYS:898:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:CLTS:585:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:CLTS:585:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:CLTS:585:PPSTRIPA MS") field(INPB, "BTM:CLTS:585:PPSTRIPB MS") } record(bi, "BTM:CLTS:585:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:CLTS:585:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:10:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:10:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:10:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:10:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:10:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:10:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:11:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:11:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:11:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:11:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:11:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:11:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:12:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:12:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:12:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:12:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:12:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:12:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:13:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:13:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:13:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:13:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:13:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:13:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:14:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:14:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:14:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:14:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:14:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:14:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:15:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:15:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:15:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:15:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:15:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:15:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:16:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:16:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:16:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:16:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:16:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:16:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:17:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:17:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:17:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:17:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:17:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:17:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:18:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:18:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:18:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:18:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:18:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:18:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:19:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:19:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:19:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:19:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:19:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:19:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:20:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:20:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:20:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:20:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:20:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:20:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:21:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:21:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:21:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:21:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:21:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:21:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:22:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:22:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:22:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:22:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:22:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:22:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:23:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:23:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:23:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:23:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:23:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:23:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:24:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:24:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:24:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:24:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:24:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:24:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:25:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:25:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:25:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:25:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:25:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:25:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:26:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:26:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:26:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:26:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:26:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:26:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:27:SPARE:PPSTRIPCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:27:SPARE:PPSTRIP") field(CALC, "A&&B") field(INPA, "BTM:BSY0:27:SPARE:PPSTRIPA MS") field(INPB, "BTM:BSY0:27:SPARE:PPSTRIPB MS") } record(bi, "BTM:BSY0:27:SPARE:PPSTRIP") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:27:SPARE:PPSTRIPCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:1:INTLK_OK_SUM_LTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:1:INTLK_OK_SUM_LTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:1:INTLK_OK_SUM_LTHA MS") field(INPB, "BTM:BSY0:1:INTLK_OK_SUM_LTHB MS") } record(bi, "BTM:BSY0:1:INTLK_OK_SUM_LTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:1:INTLK_OK_SUM_LTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:1:INTLK_OK_SUMCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:1:INTLK_OK_SUM") field(CALC, "A&&B") field(INPA, "BTM:BSY0:1:INTLK_OK_SUMA MS") field(INPB, "BTM:BSY0:1:INTLK_OK_SUMB MS") } record(bi, "BTM:BSY0:1:INTLK_OK_SUM") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "Ok") field(INP, "BTM:BSY0:1:INTLK_OK_SUMCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYH:858:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYH:858:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYH:858:PPSTRIPLTHA MS") field(INPB, "BTM:BSYH:858:PPSTRIPLTHB MS") } record(bi, "BTM:BSYH:858:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYH:858:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:2:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:2:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:2:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:2:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:2:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:2:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:1240:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:1240:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYA:1240:PPSTRIPLTHA MS") field(INPB, "BTM:BSYA:1240:PPSTRIPLTHB MS") } record(bi, "BTM:BSYA:1240:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYA:1240:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:1490:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:1490:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYA:1490:PPSTRIPLTHA MS") field(INPB, "BTM:BSYA:1490:PPSTRIPLTHB MS") } record(bi, "BTM:BSYA:1490:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYA:1490:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:2275:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:2275:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYA:2275:PPSTRIPLTHA MS") field(INPB, "BTM:BSYA:2275:PPSTRIPLTHB MS") } record(bi, "BTM:BSYA:2275:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYA:2275:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYA:2930:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYA:2930:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYA:2930:PPSTRIPLTHA MS") field(INPB, "BTM:BSYA:2930:PPSTRIPLTHB MS") } record(bi, "BTM:BSYA:2930:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYA:2930:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYS:889:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYS:889:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYS:889:PPSTRIPLTHA MS") field(INPB, "BTM:BSYS:889:PPSTRIPLTHB MS") } record(bi, "BTM:BSYS:889:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYS:889:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYS:898:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSYS:898:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSYS:898:PPSTRIPLTHA MS") field(INPB, "BTM:BSYS:898:PPSTRIPLTHB MS") } record(bi, "BTM:BSYS:898:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSYS:898:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:CLTS:585:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:CLTS:585:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:CLTS:585:PPSTRIPLTHA MS") field(INPB, "BTM:CLTS:585:PPSTRIPLTHB MS") } record(bi, "BTM:CLTS:585:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:CLTS:585:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:10:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:10:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:10:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:10:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:10:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:10:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:11:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:11:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:11:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:11:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:11:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:11:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:12:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:12:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:12:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:12:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:12:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:12:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:13:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:13:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:13:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:13:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:13:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:13:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:14:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:14:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:14:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:14:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:14:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:14:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:15:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:15:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:15:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:15:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:15:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:15:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:16:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:16:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:16:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:16:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:16:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:16:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:17:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:17:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:17:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:17:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:17:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:17:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:18:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:18:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:18:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:18:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:18:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:18:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:19:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:19:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:19:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:19:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:19:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:19:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:20:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:20:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:20:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:20:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:20:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:20:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:21:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:21:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:21:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:21:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:21:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:21:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:22:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:22:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:22:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:22:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:22:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:22:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:23:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:23:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:23:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:23:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:23:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:23:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:24:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:24:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:24:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:24:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:24:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:24:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:25:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:25:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:25:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:25:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:25:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:25:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:26:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:26:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:26:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:26:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:26:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:26:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSY0:27:SPARE:PPSTRIPLTHCALC") { field(SCAN, ".1 second") field(DESC, "summary_calculation") field(FLNK, "BTM:BSY0:27:SPARE:PPSTRIPLTH") field(CALC, "A&&B") field(INPA, "BTM:BSY0:27:SPARE:PPSTRIPLTHA MS") field(INPB, "BTM:BSY0:27:SPARE:PPSTRIPLTHB MS") } record(bi, "BTM:BSY0:27:SPARE:PPSTRIPLTH") { field(SCAN, "Passive") field(DESC, "summary") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "BTM:BSY0:27:SPARE:PPSTRIPLTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bo, "BTM:BSY0:1:RESET_INTLK_A") { field(DESC, "BTM_Interlock_Reset_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BTM:BSY0:1:PAUSEHB_A") { field(DESC, "BTM_Pause_Heartbeat_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BTM:BSY0:1:RESET_INTLK_B") { field(DESC, "BTM_Interlock_Reset_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BTM:BSY0:1:PAUSEHB_B") { field(DESC, "BTM_Pause_Heartbeat_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BTM:BSY0:1:RESET_INTLK"){ field(DESC, "BTM_Interlock_Reset") field(OUT, "BTM:BSY0:1:RESET_INTLK_FANOUT PP") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(dfanout, "BTM:BSY0:1:RESET_INTLK_FANOUT"){ field(OUTA, "BTM:BSY0:1:RESET_INTLK_A PP") field(OUTB, "BTM:BSY0:1:RESET_INTLK_B PP") field(ASG, "MCC") } record(bo, "BTM:BSY0:1:PAUSEHB"){ field(DESC, "BTM_Pause_Heartbeat") field(OUT, "BTM:BSY0:1:PAUSEHB_FANOUT PP") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(dfanout, "BTM:BSY0:1:PAUSEHB_FANOUT"){ field(OUTA, "BTM:BSY0:1:PAUSEHB_A PP") field(OUTB, "BTM:BSY0:1:PAUSEHB_B PP") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP03:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP03:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP03:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP03:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP03:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP03:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP03:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP03:REQ_SEG CP") field( INPC, "PLC:BSY0:PP03:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP03:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP03:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP03:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP03:REQ_SEG CP") field( INPC, "PLC:BSY0:PP03:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP03:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP03:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP03:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP03:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP03:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP03:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP03:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP03:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP03:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP03:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP03:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP03:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP03:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP03:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP03:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP03:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP03:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP03:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP03:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP03:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP03:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP03:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP03:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP03:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP03:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP03:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP03:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP03:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP03:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP03:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP03:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP03:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP03:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP03:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP03:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP03:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP03:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP03:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP03:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP03:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP03:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP03:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP03:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP03:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP03:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP03:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP03:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP03:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP03:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP03:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP03:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP03:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP03:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP03:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP04:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP04:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP04:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP04:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP04:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP04:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP04:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP04:REQ_SEG CP") field( INPC, "PLC:BSY0:PP04:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP04:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP04:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP04:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP04:REQ_SEG CP") field( INPC, "PLC:BSY0:PP04:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP04:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP04:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP04:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP04:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP04:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP04:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP04:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP04:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP04:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP04:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP04:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP04:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP04:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP04:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP04:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP04:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP04:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP04:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP04:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP04:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP04:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP04:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP04:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP04:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP04:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP04:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP04:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP04:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP04:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP04:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP04:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP04:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP04:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP04:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP04:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP04:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP04:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP04:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP04:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP04:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP04:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP04:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP04:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP04:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP04:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP04:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP04:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP04:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP04:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP04:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP04:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP04:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP04:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_RDB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP04:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BTM_WRTB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP03:w0") { field(DESC, "BTM PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:w1") { field(DESC, "BTM PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP03:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP03:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP03:w3") { field(DESC, "BTM PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP03:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP03:w3 PP MS") field(INPB, "PLC:BSY0:PP03:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP03:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP03:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP03:w4") { field(DESC, "BTM PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP03:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP03:w4 NPP MS") field(INPB, "PLC:BSY0:PP03:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP03:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP03:w5") { field(DESC, "BTM PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP03:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP03:w5 NPP MS") field(INPB, "PLC:BSY0:PP03:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP03:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP03:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP03:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP03:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP03:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP03:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP03:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP03:w6 NPP MS") field(INPB, "PLC:BSY0:PP03:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP03:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP03:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP03:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP03:w7 NPP MS") field(INPB, "PLC:BSY0:PP03:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP03:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDA, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP03:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP03:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP03:w8 NPP MS") field(INPB, "PLC:BSY0:PP03:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP03:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP03:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP03:OP_HOURS") { field(INPA, "PLC:BSY0:PP03:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP03:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP03:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP03:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP04:w0") { field(DESC, "BTM PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:w1") { field(DESC, "BTM PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP04:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP04:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP04:w3") { field(DESC, "BTM PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP04:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP04:w3 PP MS") field(INPB, "PLC:BSY0:PP04:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP04:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP04:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP04:w4") { field(DESC, "BTM PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP04:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP04:w4 NPP MS") field(INPB, "PLC:BSY0:PP04:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP04:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP04:w5") { field(DESC, "BTM PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP04:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP04:w5 NPP MS") field(INPB, "PLC:BSY0:PP04:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP04:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP04:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP04:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP04:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP04:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP04:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP04:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP04:w6 NPP MS") field(INPB, "PLC:BSY0:PP04:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP04:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP04:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP04:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP04:w7 NPP MS") field(INPB, "PLC:BSY0:PP04:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP04:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BTM_WDB, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP04:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP04:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP04:w8 NPP MS") field(INPB, "PLC:BSY0:PP04:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP04:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP04:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP04:OP_HOURS") { field(INPA, "PLC:BSY0:PP04:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP04:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP04:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP04:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP03:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BTM_RDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP03:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP03:RDHist.PROC") } record(waveform,"PLC:BSY0:PP03:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_RDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP03:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP03:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_RDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP03:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP03:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BTM_RDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP03:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP03:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP03:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP03:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP03:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP03:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP03:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP03:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP03:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP03:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BTM_WRTA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP03:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP03:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP03:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WRTA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP03:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP03:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WRTA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP03:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP03:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BTM_WRTA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP03:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTA 0)READ_OK") field(FLNK,"PLC:BSY0:PP03:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP03:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP03:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP03:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP03:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP03:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP03:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP03:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP03:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BTM_WDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP03:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP03:WDHist.PROC") } record(waveform,"PLC:BSY0:PP03:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP03:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP03:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP03:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP03:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BTM_WDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP03:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP03:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP03:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP03:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP03:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP03:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP03:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP03:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP03:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP04:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BTM_RDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP04:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP04:RDHist.PROC") } record(waveform,"PLC:BSY0:PP04:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_RDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP04:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP04:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_RDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP04:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP04:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BTM_RDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP04:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP04:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP04:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP04:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP04:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP04:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP04:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP04:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP04:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_RDB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP04:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BTM_WRTB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP04:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP04:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP04:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WRTB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP04:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP04:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WRTB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP04:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP04:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BTM_WRTB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP04:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTB 0)READ_OK") field(FLNK,"PLC:BSY0:PP04:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP04:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP04:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP04:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP04:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP04:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP04:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP04:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WRTB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP04:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BTM_WDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP04:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP04:WDHist.PROC") } record(waveform,"PLC:BSY0:PP04:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP04:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP04:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BTM_WDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP04:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP04:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BTM_WDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP04:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP04:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP04:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP04:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP04:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP04:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP04:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP04:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP04:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BTM_WDB 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi7") { field(DESC, "Port BSOIC_RD bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BSOC:BSY0:1:RTHWEN_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWEN_calc") { field(INPA, "PLC:BSY0:BC01:Bi7 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWEN PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWEN") { field(DESC, "BSOIC-HW_Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb7",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb7") #! Field("PLC:BSY0:BC01:BSOIC_RDb7.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb7.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb7.FLNK","BSOC:BSY0:1:RTHWEN_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb7.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb7.VAL") #! Record("BSOC:BSY0:1:RTHWEN_calc",260,18,0,1,"BSOC:BSY0:1:RTHWEN_calc") #! Field("BSOC:BSY0:1:RTHWEN_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWEN_calc.INPA") #! Link("BSOC:BSY0:1:RTHWEN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb7.VAL") #! Field("BSOC:BSY0:1:RTHWEN_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWEN_calc.INPB") #! Field("BSOC:BSY0:1:RTHWEN_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWEN_calc.OUT") #! Link("BSOC:BSY0:1:RTHWEN_calc.OUT","BSOC:BSY0:1:RTHWEN.VAL") #! Record("BSOC:BSY0:1:RTHWEN",500,20,0,0,"BSOC:BSY0:1:RTHWEN") #! Field("BSOC:BSY0:1:RTHWEN.VAL",16777215,1,"BSOC:BSY0:1:RTHWEN.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi6") { field(DESC, "Port BSOIC_RD bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:BSY0:1:RTHWRESETALL_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWRESETALL_calc") { field(INPA, "PLC:BSY0:BC01:Bi6 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWRESETALL PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWRESETALL") { field(DESC, "BSOIC-HW_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb6",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb6") #! Field("PLC:BSY0:BC01:BSOIC_RDb6.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb6.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb6.FLNK","BSOC:BSY0:1:RTHWRESETALL_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb6.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb6.VAL") #! Record("BSOC:BSY0:1:RTHWRESETALL_calc",260,18,0,1,"BSOC:BSY0:1:RTHWRESETALL_calc") #! Field("BSOC:BSY0:1:RTHWRESETALL_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWRESETALL_calc.INPA") #! Link("BSOC:BSY0:1:RTHWRESETALL_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb6.VAL") #! Field("BSOC:BSY0:1:RTHWRESETALL_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWRESETALL_calc.INPB") #! Field("BSOC:BSY0:1:RTHWRESETALL_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWRESETALL_calc.OUT") #! Link("BSOC:BSY0:1:RTHWRESETALL_calc.OUT","BSOC:BSY0:1:RTHWRESETALL.VAL") #! Record("BSOC:BSY0:1:RTHWRESETALL",500,20,0,0,"BSOC:BSY0:1:RTHWRESETALL") #! Field("BSOC:BSY0:1:RTHWRESETALL.VAL",16777215,1,"BSOC:BSY0:1:RTHWRESETALL.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi5") { field(DESC, "Port BSOIC_RD bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi5 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTEQP") { field(DESC, "BSOIC-RT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb5",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb5") #! Field("PLC:BSY0:BC01:BSOIC_RDb5.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb5.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb5.FLNK","BSOC:BSY0:1:RTEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb5.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb5.VAL") #! Record("BSOC:BSY0:1:RTEQP_calc",260,18,0,1,"BSOC:BSY0:1:RTEQP_calc") #! Field("BSOC:BSY0:1:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:1:RTEQP_calc.INPA") #! Link("BSOC:BSY0:1:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb5.VAL") #! Field("BSOC:BSY0:1:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:1:RTEQP_calc.INPB") #! Field("BSOC:BSY0:1:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:1:RTEQP_calc.OUT") #! Link("BSOC:BSY0:1:RTEQP_calc.OUT","BSOC:BSY0:1:RTEQP.VAL") #! Record("BSOC:BSY0:1:RTEQP",500,20,0,0,"BSOC:BSY0:1:RTEQP") #! Field("BSOC:BSY0:1:RTEQP.VAL",16777215,1,"BSOC:BSY0:1:RTEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi4") { field(DESC, "Port BSOIC_RD bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 4, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi4 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTRAD") { field(DESC, "BSOIC-RT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb4",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb4") #! Field("PLC:BSY0:BC01:BSOIC_RDb4.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb4.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb4.FLNK","BSOC:BSY0:1:RTRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb4.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb4.VAL") #! Record("BSOC:BSY0:1:RTRAD_calc",260,18,0,1,"BSOC:BSY0:1:RTRAD_calc") #! Field("BSOC:BSY0:1:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:1:RTRAD_calc.INPA") #! Link("BSOC:BSY0:1:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb4.VAL") #! Field("BSOC:BSY0:1:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:1:RTRAD_calc.INPB") #! Field("BSOC:BSY0:1:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:1:RTRAD_calc.OUT") #! Link("BSOC:BSY0:1:RTRAD_calc.OUT","BSOC:BSY0:1:RTRAD.VAL") #! Record("BSOC:BSY0:1:RTRAD",500,20,0,0,"BSOC:BSY0:1:RTRAD") #! Field("BSOC:BSY0:1:RTRAD.VAL",16777215,1,"BSOC:BSY0:1:RTRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi3") { field(DESC, "Port BSOIC_RD bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:BSY0:1:RTHWBYP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWBYP_calc") { field(INPA, "PLC:BSY0:BC01:Bi3 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWBYP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWBYP") { field(DESC, "BSOIC-RT_G1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb3",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb3") #! Field("PLC:BSY0:BC01:BSOIC_RDb3.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb3.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb3.FLNK","BSOC:BSY0:1:RTHWBYP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb3.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb3.VAL") #! Record("BSOC:BSY0:1:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:1:RTHWBYP_calc") #! Field("BSOC:BSY0:1:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWBYP_calc.INPA") #! Link("BSOC:BSY0:1:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb3.VAL") #! Field("BSOC:BSY0:1:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWBYP_calc.INPB") #! Field("BSOC:BSY0:1:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWBYP_calc.OUT") #! Link("BSOC:BSY0:1:RTHWBYP_calc.OUT","BSOC:BSY0:1:RTHWBYP.VAL") #! Record("BSOC:BSY0:1:RTHWBYP",500,20,0,0,"BSOC:BSY0:1:RTHWBYP") #! Field("BSOC:BSY0:1:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:1:RTHWBYP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi2") { field(DESC, "Port BSOIC_RD bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:3:RTEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:RTEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi2 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:RTEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:RTEQP") { field(DESC, "BSOIC-RT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb2",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb2") #! Field("PLC:BSY0:BC01:BSOIC_RDb2.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb2.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb2.FLNK","BSOC:BSY0:3:RTEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb2.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb2.VAL") #! Record("BSOC:BSY0:3:RTEQP_calc",260,18,0,1,"BSOC:BSY0:3:RTEQP_calc") #! Field("BSOC:BSY0:3:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:3:RTEQP_calc.INPA") #! Link("BSOC:BSY0:3:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb2.VAL") #! Field("BSOC:BSY0:3:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:3:RTEQP_calc.INPB") #! Field("BSOC:BSY0:3:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:3:RTEQP_calc.OUT") #! Link("BSOC:BSY0:3:RTEQP_calc.OUT","BSOC:BSY0:3:RTEQP.VAL") #! Record("BSOC:BSY0:3:RTEQP",500,20,0,0,"BSOC:BSY0:3:RTEQP") #! Field("BSOC:BSY0:3:RTEQP.VAL",16777215,1,"BSOC:BSY0:3:RTEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi1") { field(DESC, "Port BSOIC_RD bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:3:RTRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:RTRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi1 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:RTRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:RTRAD") { field(DESC, "BSOIC-RT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb1",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb1") #! Field("PLC:BSY0:BC01:BSOIC_RDb1.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb1.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb1.FLNK","BSOC:BSY0:3:RTRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb1.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb1.VAL") #! Record("BSOC:BSY0:3:RTRAD_calc",260,18,0,1,"BSOC:BSY0:3:RTRAD_calc") #! Field("BSOC:BSY0:3:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:3:RTRAD_calc.INPA") #! Link("BSOC:BSY0:3:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb1.VAL") #! Field("BSOC:BSY0:3:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:3:RTRAD_calc.INPB") #! Field("BSOC:BSY0:3:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:3:RTRAD_calc.OUT") #! Link("BSOC:BSY0:3:RTRAD_calc.OUT","BSOC:BSY0:3:RTRAD.VAL") #! Record("BSOC:BSY0:3:RTRAD",500,20,0,0,"BSOC:BSY0:3:RTRAD") #! Field("BSOC:BSY0:3:RTRAD.VAL",16777215,1,"BSOC:BSY0:3:RTRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi0") { field(DESC, "Port BSOIC_RD bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:BSY0:3:RTHWBYP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:RTHWBYP_calc") { field(INPA, "PLC:BSY0:BC01:Bi0 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:RTHWBYP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:RTHWBYP") { field(DESC, "BSOIC-RT_G2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb0",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb0") #! Field("PLC:BSY0:BC01:BSOIC_RDb0.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb0.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb0.FLNK","BSOC:BSY0:3:RTHWBYP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb0.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb0.VAL") #! Record("BSOC:BSY0:3:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:3:RTHWBYP_calc") #! Field("BSOC:BSY0:3:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:3:RTHWBYP_calc.INPA") #! Link("BSOC:BSY0:3:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb0.VAL") #! Field("BSOC:BSY0:3:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:3:RTHWBYP_calc.INPB") #! Field("BSOC:BSY0:3:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:3:RTHWBYP_calc.OUT") #! Link("BSOC:BSY0:3:RTHWBYP_calc.OUT","BSOC:BSY0:3:RTHWBYP.VAL") #! Record("BSOC:BSY0:3:RTHWBYP",500,20,0,0,"BSOC:BSY0:3:RTHWBYP") #! Field("BSOC:BSY0:3:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:3:RTHWBYP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi15") { field(DESC, "Port BSOIC_RD bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:4:RTEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:RTEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi15 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:RTEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:RTEQP") { field(DESC, "BSOIC-RT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb15",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb15") #! Field("PLC:BSY0:BC01:BSOIC_RDb15.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb15.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb15.FLNK","BSOC:BSY0:4:RTEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb15.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb15.VAL") #! Record("BSOC:BSY0:4:RTEQP_calc",260,18,0,1,"BSOC:BSY0:4:RTEQP_calc") #! Field("BSOC:BSY0:4:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:4:RTEQP_calc.INPA") #! Link("BSOC:BSY0:4:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb15.VAL") #! Field("BSOC:BSY0:4:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:4:RTEQP_calc.INPB") #! Field("BSOC:BSY0:4:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:4:RTEQP_calc.OUT") #! Link("BSOC:BSY0:4:RTEQP_calc.OUT","BSOC:BSY0:4:RTEQP.VAL") #! Record("BSOC:BSY0:4:RTEQP",500,20,0,0,"BSOC:BSY0:4:RTEQP") #! Field("BSOC:BSY0:4:RTEQP.VAL",16777215,1,"BSOC:BSY0:4:RTEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi14") { field(DESC, "Port BSOIC_RD bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:4:RTRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:RTRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi14 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:RTRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:RTRAD") { field(DESC, "BSOIC-RT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb14",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb14") #! Field("PLC:BSY0:BC01:BSOIC_RDb14.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb14.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb14.FLNK","BSOC:BSY0:4:RTRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb14.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb14.VAL") #! Record("BSOC:BSY0:4:RTRAD_calc",260,18,0,1,"BSOC:BSY0:4:RTRAD_calc") #! Field("BSOC:BSY0:4:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:4:RTRAD_calc.INPA") #! Link("BSOC:BSY0:4:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb14.VAL") #! Field("BSOC:BSY0:4:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:4:RTRAD_calc.INPB") #! Field("BSOC:BSY0:4:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:4:RTRAD_calc.OUT") #! Link("BSOC:BSY0:4:RTRAD_calc.OUT","BSOC:BSY0:4:RTRAD.VAL") #! Record("BSOC:BSY0:4:RTRAD",500,20,0,0,"BSOC:BSY0:4:RTRAD") #! Field("BSOC:BSY0:4:RTRAD.VAL",16777215,1,"BSOC:BSY0:4:RTRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi13") { field(DESC, "Port BSOIC_RD bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 13, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:BSY0:4:RTHWBYP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:RTHWBYP_calc") { field(INPA, "PLC:BSY0:BC01:Bi13 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:RTHWBYP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:RTHWBYP") { field(DESC, "BSOIC-RT_G3_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb13",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb13") #! Field("PLC:BSY0:BC01:BSOIC_RDb13.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb13.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb13.FLNK","BSOC:BSY0:4:RTHWBYP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb13.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb13.VAL") #! Record("BSOC:BSY0:4:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:4:RTHWBYP_calc") #! Field("BSOC:BSY0:4:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:4:RTHWBYP_calc.INPA") #! Link("BSOC:BSY0:4:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb13.VAL") #! Field("BSOC:BSY0:4:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:4:RTHWBYP_calc.INPB") #! Field("BSOC:BSY0:4:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:4:RTHWBYP_calc.OUT") #! Link("BSOC:BSY0:4:RTHWBYP_calc.OUT","BSOC:BSY0:4:RTHWBYP.VAL") #! Record("BSOC:BSY0:4:RTHWBYP",500,20,0,0,"BSOC:BSY0:4:RTHWBYP") #! Field("BSOC:BSY0:4:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:4:RTHWBYP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi12") { field(DESC, "Port BSOIC_RD bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:5:RTEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:RTEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi12 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:RTEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:RTEQP") { field(DESC, "BSOIC-RT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb12",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb12") #! Field("PLC:BSY0:BC01:BSOIC_RDb12.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb12.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb12.FLNK","BSOC:BSY0:5:RTEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb12.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb12.VAL") #! Record("BSOC:BSY0:5:RTEQP_calc",260,18,0,1,"BSOC:BSY0:5:RTEQP_calc") #! Field("BSOC:BSY0:5:RTEQP_calc.INPA",16777215,0,"BSOC:BSY0:5:RTEQP_calc.INPA") #! Link("BSOC:BSY0:5:RTEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb12.VAL") #! Field("BSOC:BSY0:5:RTEQP_calc.INPB",16777215,1,"BSOC:BSY0:5:RTEQP_calc.INPB") #! Field("BSOC:BSY0:5:RTEQP_calc.OUT",16777215,1,"BSOC:BSY0:5:RTEQP_calc.OUT") #! Link("BSOC:BSY0:5:RTEQP_calc.OUT","BSOC:BSY0:5:RTEQP.VAL") #! Record("BSOC:BSY0:5:RTEQP",500,20,0,0,"BSOC:BSY0:5:RTEQP") #! Field("BSOC:BSY0:5:RTEQP.VAL",16777215,1,"BSOC:BSY0:5:RTEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi11") { field(DESC, "Port BSOIC_RD bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:5:RTRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:RTRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi11 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:RTRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:RTRAD") { field(DESC, "BSOIC-RT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb11",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb11") #! Field("PLC:BSY0:BC01:BSOIC_RDb11.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb11.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb11.FLNK","BSOC:BSY0:5:RTRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb11.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb11.VAL") #! Record("BSOC:BSY0:5:RTRAD_calc",260,18,0,1,"BSOC:BSY0:5:RTRAD_calc") #! Field("BSOC:BSY0:5:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:5:RTRAD_calc.INPA") #! Link("BSOC:BSY0:5:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb11.VAL") #! Field("BSOC:BSY0:5:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:5:RTRAD_calc.INPB") #! Field("BSOC:BSY0:5:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:5:RTRAD_calc.OUT") #! Link("BSOC:BSY0:5:RTRAD_calc.OUT","BSOC:BSY0:5:RTRAD.VAL") #! Record("BSOC:BSY0:5:RTRAD",500,20,0,0,"BSOC:BSY0:5:RTRAD") #! Field("BSOC:BSY0:5:RTRAD.VAL",16777215,1,"BSOC:BSY0:5:RTRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi10") { field(DESC, "Port BSOIC_RD bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 10, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:BSY0:5:RTHWBYP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:RTHWBYP_calc") { field(INPA, "PLC:BSY0:BC01:Bi10 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:RTHWBYP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:RTHWBYP") { field(DESC, "BSOIC-RT_G4_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb10",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb10") #! Field("PLC:BSY0:BC01:BSOIC_RDb10.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb10.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb10.FLNK","BSOC:BSY0:5:RTHWBYP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb10.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb10.VAL") #! Record("BSOC:BSY0:5:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:5:RTHWBYP_calc") #! Field("BSOC:BSY0:5:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:5:RTHWBYP_calc.INPA") #! Link("BSOC:BSY0:5:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb10.VAL") #! Field("BSOC:BSY0:5:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:5:RTHWBYP_calc.INPB") #! Field("BSOC:BSY0:5:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:5:RTHWBYP_calc.OUT") #! Link("BSOC:BSY0:5:RTHWBYP_calc.OUT","BSOC:BSY0:5:RTHWBYP.VAL") #! Record("BSOC:BSY0:5:RTHWBYP",500,20,0,0,"BSOC:BSY0:5:RTHWBYP") #! Field("BSOC:BSY0:5:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:5:RTHWBYP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi9") { field(DESC, "Port BSOIC_RD bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:2:RTRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:2:RTRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi9 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:2:RTRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:2:RTRAD") { field(DESC, "BSOIC-RT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb9",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb9") #! Field("PLC:BSY0:BC01:BSOIC_RDb9.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb9.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb9.FLNK","BSOC:BSY0:2:RTRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb9.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb9.VAL") #! Record("BSOC:BSY0:2:RTRAD_calc",260,18,0,1,"BSOC:BSY0:2:RTRAD_calc") #! Field("BSOC:BSY0:2:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:2:RTRAD_calc.INPA") #! Link("BSOC:BSY0:2:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb9.VAL") #! Field("BSOC:BSY0:2:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:2:RTRAD_calc.INPB") #! Field("BSOC:BSY0:2:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:2:RTRAD_calc.OUT") #! Link("BSOC:BSY0:2:RTRAD_calc.OUT","BSOC:BSY0:2:RTRAD.VAL") #! Record("BSOC:BSY0:2:RTRAD",500,20,0,0,"BSOC:BSY0:2:RTRAD") #! Field("BSOC:BSY0:2:RTRAD.VAL",16777215,1,"BSOC:BSY0:2:RTRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi8") { field(DESC, "Port BSOIC_RD bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 8, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:BSY0:2:RTHWBYP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:2:RTHWBYP_calc") { field(INPA, "PLC:BSY0:BC01:Bi8 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:2:RTHWBYP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:2:RTHWBYP") { field(DESC, "BSOIC-RT_N1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb8",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb8") #! Field("PLC:BSY0:BC01:BSOIC_RDb8.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb8.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb8.FLNK","BSOC:BSY0:2:RTHWBYP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb8.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb8.VAL") #! Record("BSOC:BSY0:2:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:2:RTHWBYP_calc") #! Field("BSOC:BSY0:2:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:2:RTHWBYP_calc.INPA") #! Link("BSOC:BSY0:2:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb8.VAL") #! Field("BSOC:BSY0:2:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:2:RTHWBYP_calc.INPB") #! Field("BSOC:BSY0:2:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:2:RTHWBYP_calc.OUT") #! Link("BSOC:BSY0:2:RTHWBYP_calc.OUT","BSOC:BSY0:2:RTHWBYP.VAL") #! Record("BSOC:BSY0:2:RTHWBYP",500,20,0,0,"BSOC:BSY0:2:RTHWBYP") #! Field("BSOC:BSY0:2:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:2:RTHWBYP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi23") { field(DESC, "Port BSOIC_RD bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:6:RTRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:6:RTRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi23 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:6:RTRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:6:RTRAD") { field(DESC, "BSOIC-RT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb23",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb23") #! Field("PLC:BSY0:BC01:BSOIC_RDb23.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb23.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb23.FLNK","BSOC:BSY0:6:RTRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb23.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb23.VAL") #! Record("BSOC:BSY0:6:RTRAD_calc",260,18,0,1,"BSOC:BSY0:6:RTRAD_calc") #! Field("BSOC:BSY0:6:RTRAD_calc.INPA",16777215,0,"BSOC:BSY0:6:RTRAD_calc.INPA") #! Link("BSOC:BSY0:6:RTRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb23.VAL") #! Field("BSOC:BSY0:6:RTRAD_calc.INPB",16777215,1,"BSOC:BSY0:6:RTRAD_calc.INPB") #! Field("BSOC:BSY0:6:RTRAD_calc.OUT",16777215,1,"BSOC:BSY0:6:RTRAD_calc.OUT") #! Link("BSOC:BSY0:6:RTRAD_calc.OUT","BSOC:BSY0:6:RTRAD.VAL") #! Record("BSOC:BSY0:6:RTRAD",500,20,0,0,"BSOC:BSY0:6:RTRAD") #! Field("BSOC:BSY0:6:RTRAD.VAL",16777215,1,"BSOC:BSY0:6:RTRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi22") { field(DESC, "Port BSOIC_RD bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 22, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:BSY0:6:RTHWBYP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:6:RTHWBYP_calc") { field(INPA, "PLC:BSY0:BC01:Bi22 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:6:RTHWBYP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:6:RTHWBYP") { field(DESC, "BSOIC-RT_N2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb22",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb22") #! Field("PLC:BSY0:BC01:BSOIC_RDb22.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb22.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb22.FLNK","BSOC:BSY0:6:RTHWBYP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb22.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb22.VAL") #! Record("BSOC:BSY0:6:RTHWBYP_calc",260,18,0,1,"BSOC:BSY0:6:RTHWBYP_calc") #! Field("BSOC:BSY0:6:RTHWBYP_calc.INPA",16777215,0,"BSOC:BSY0:6:RTHWBYP_calc.INPA") #! Link("BSOC:BSY0:6:RTHWBYP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb22.VAL") #! Field("BSOC:BSY0:6:RTHWBYP_calc.INPB",16777215,1,"BSOC:BSY0:6:RTHWBYP_calc.INPB") #! Field("BSOC:BSY0:6:RTHWBYP_calc.OUT",16777215,1,"BSOC:BSY0:6:RTHWBYP_calc.OUT") #! Link("BSOC:BSY0:6:RTHWBYP_calc.OUT","BSOC:BSY0:6:RTHWBYP.VAL") #! Record("BSOC:BSY0:6:RTHWBYP",500,20,0,0,"BSOC:BSY0:6:RTHWBYP") #! Field("BSOC:BSY0:6:RTHWBYP.VAL",16777215,1,"BSOC:BSY0:6:RTHWBYP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi21") { field(DESC, "Port BSOIC_RD bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTCASCI_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTCASCI_calc") { field(INPA, "PLC:BSY0:BC01:Bi21 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTCASCI PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTCASCI") { field(DESC, "BSOIC-RT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb21",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb21") #! Field("PLC:BSY0:BC01:BSOIC_RDb21.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb21.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb21.FLNK","BSOC:BSY0:1:RTCASCI_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb21.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb21.VAL") #! Record("BSOC:BSY0:1:RTCASCI_calc",260,18,0,1,"BSOC:BSY0:1:RTCASCI_calc") #! Field("BSOC:BSY0:1:RTCASCI_calc.INPA",16777215,0,"BSOC:BSY0:1:RTCASCI_calc.INPA") #! Link("BSOC:BSY0:1:RTCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb21.VAL") #! Field("BSOC:BSY0:1:RTCASCI_calc.INPB",16777215,1,"BSOC:BSY0:1:RTCASCI_calc.INPB") #! Field("BSOC:BSY0:1:RTCASCI_calc.OUT",16777215,1,"BSOC:BSY0:1:RTCASCI_calc.OUT") #! Link("BSOC:BSY0:1:RTCASCI_calc.OUT","BSOC:BSY0:1:RTCASCI.VAL") #! Record("BSOC:BSY0:1:RTCASCI",500,20,0,0,"BSOC:BSY0:1:RTCASCI") #! Field("BSOC:BSY0:1:RTCASCI.VAL",16777215,1,"BSOC:BSY0:1:RTCASCI.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi20") { field(DESC, "Port BSOIC_RD bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:2:RTCASCI_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:2:RTCASCI_calc") { field(INPA, "PLC:BSY0:BC01:Bi20 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:2:RTCASCI PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:2:RTCASCI") { field(DESC, "BSOIC-RT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb20",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb20") #! Field("PLC:BSY0:BC01:BSOIC_RDb20.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb20.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb20.FLNK","BSOC:BSY0:2:RTCASCI_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb20.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb20.VAL") #! Record("BSOC:BSY0:2:RTCASCI_calc",260,18,0,1,"BSOC:BSY0:2:RTCASCI_calc") #! Field("BSOC:BSY0:2:RTCASCI_calc.INPA",16777215,0,"BSOC:BSY0:2:RTCASCI_calc.INPA") #! Link("BSOC:BSY0:2:RTCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb20.VAL") #! Field("BSOC:BSY0:2:RTCASCI_calc.INPB",16777215,1,"BSOC:BSY0:2:RTCASCI_calc.INPB") #! Field("BSOC:BSY0:2:RTCASCI_calc.OUT",16777215,1,"BSOC:BSY0:2:RTCASCI_calc.OUT") #! Link("BSOC:BSY0:2:RTCASCI_calc.OUT","BSOC:BSY0:2:RTCASCI.VAL") #! Record("BSOC:BSY0:2:RTCASCI",500,20,0,0,"BSOC:BSY0:2:RTCASCI") #! Field("BSOC:BSY0:2:RTCASCI.VAL",16777215,1,"BSOC:BSY0:2:RTCASCI.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi19") { field(DESC, "Port BSOIC_RD bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 19, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:BSY0:1:RTSORST_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTSORST_calc") { field(INPA, "PLC:BSY0:BC01:Bi19 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTSORST PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTSORST") { field(DESC, "BSOIC-G1_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb19",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb19") #! Field("PLC:BSY0:BC01:BSOIC_RDb19.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb19.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb19.FLNK","BSOC:BSY0:1:RTSORST_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb19.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb19.VAL") #! Record("BSOC:BSY0:1:RTSORST_calc",260,18,0,1,"BSOC:BSY0:1:RTSORST_calc") #! Field("BSOC:BSY0:1:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:1:RTSORST_calc.INPA") #! Link("BSOC:BSY0:1:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb19.VAL") #! Field("BSOC:BSY0:1:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:1:RTSORST_calc.INPB") #! Field("BSOC:BSY0:1:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:1:RTSORST_calc.OUT") #! Link("BSOC:BSY0:1:RTSORST_calc.OUT","BSOC:BSY0:1:RTSORST.VAL") #! Record("BSOC:BSY0:1:RTSORST",500,20,0,0,"BSOC:BSY0:1:RTSORST") #! Field("BSOC:BSY0:1:RTSORST.VAL",16777215,1,"BSOC:BSY0:1:RTSORST.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi18") { field(DESC, "Port BSOIC_RD bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 18, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:BSY0:3:RTSORST_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:RTSORST_calc") { field(INPA, "PLC:BSY0:BC01:Bi18 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:RTSORST PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:RTSORST") { field(DESC, "BSOIC-G2_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb18",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb18") #! Field("PLC:BSY0:BC01:BSOIC_RDb18.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb18.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb18.FLNK","BSOC:BSY0:3:RTSORST_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb18.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb18.VAL") #! Record("BSOC:BSY0:3:RTSORST_calc",260,18,0,1,"BSOC:BSY0:3:RTSORST_calc") #! Field("BSOC:BSY0:3:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:3:RTSORST_calc.INPA") #! Link("BSOC:BSY0:3:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb18.VAL") #! Field("BSOC:BSY0:3:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:3:RTSORST_calc.INPB") #! Field("BSOC:BSY0:3:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:3:RTSORST_calc.OUT") #! Link("BSOC:BSY0:3:RTSORST_calc.OUT","BSOC:BSY0:3:RTSORST.VAL") #! Record("BSOC:BSY0:3:RTSORST",500,20,0,0,"BSOC:BSY0:3:RTSORST") #! Field("BSOC:BSY0:3:RTSORST.VAL",16777215,1,"BSOC:BSY0:3:RTSORST.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi17") { field(DESC, "Port BSOIC_RD bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 17, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:BSY0:4:RTSORST_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:RTSORST_calc") { field(INPA, "PLC:BSY0:BC01:Bi17 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:RTSORST PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:RTSORST") { field(DESC, "BSOIC-G3_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb17",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb17") #! Field("PLC:BSY0:BC01:BSOIC_RDb17.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb17.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb17.FLNK","BSOC:BSY0:4:RTSORST_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb17.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb17.VAL") #! Record("BSOC:BSY0:4:RTSORST_calc",260,18,0,1,"BSOC:BSY0:4:RTSORST_calc") #! Field("BSOC:BSY0:4:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:4:RTSORST_calc.INPA") #! Link("BSOC:BSY0:4:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb17.VAL") #! Field("BSOC:BSY0:4:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:4:RTSORST_calc.INPB") #! Field("BSOC:BSY0:4:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:4:RTSORST_calc.OUT") #! Link("BSOC:BSY0:4:RTSORST_calc.OUT","BSOC:BSY0:4:RTSORST.VAL") #! Record("BSOC:BSY0:4:RTSORST",500,20,0,0,"BSOC:BSY0:4:RTSORST") #! Field("BSOC:BSY0:4:RTSORST.VAL",16777215,1,"BSOC:BSY0:4:RTSORST.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi16") { field(DESC, "Port BSOIC_RD bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 16, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:BSY0:5:RTSORST_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:RTSORST_calc") { field(INPA, "PLC:BSY0:BC01:Bi16 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:RTSORST PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:RTSORST") { field(DESC, "BSOIC-G4_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb16",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb16") #! Field("PLC:BSY0:BC01:BSOIC_RDb16.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb16.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb16.FLNK","BSOC:BSY0:5:RTSORST_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb16.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb16.VAL") #! Record("BSOC:BSY0:5:RTSORST_calc",260,18,0,1,"BSOC:BSY0:5:RTSORST_calc") #! Field("BSOC:BSY0:5:RTSORST_calc.INPA",16777215,0,"BSOC:BSY0:5:RTSORST_calc.INPA") #! Link("BSOC:BSY0:5:RTSORST_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb16.VAL") #! Field("BSOC:BSY0:5:RTSORST_calc.INPB",16777215,1,"BSOC:BSY0:5:RTSORST_calc.INPB") #! Field("BSOC:BSY0:5:RTSORST_calc.OUT",16777215,1,"BSOC:BSY0:5:RTSORST_calc.OUT") #! Link("BSOC:BSY0:5:RTSORST_calc.OUT","BSOC:BSY0:5:RTSORST.VAL") #! Record("BSOC:BSY0:5:RTSORST",500,20,0,0,"BSOC:BSY0:5:RTSORST") #! Field("BSOC:BSY0:5:RTSORST.VAL",16777215,1,"BSOC:BSY0:5:RTSORST.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi95") { field(DESC, "Port BSOIC_RD bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 95, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:BSY0:1:RTANNALARM_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTANNALARM_calc") { field(INPA, "PLC:BSY0:BC01:Bi95 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTANNALARM PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTANNALARM") { field(DESC, "BSOIC-HW_Annunciator_Alarm") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb95",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb95") #! Field("PLC:BSY0:BC01:BSOIC_RDb95.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb95.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb95.FLNK","BSOC:BSY0:1:RTANNALARM_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb95.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb95.VAL") #! Record("BSOC:BSY0:1:RTANNALARM_calc",260,18,0,1,"BSOC:BSY0:1:RTANNALARM_calc") #! Field("BSOC:BSY0:1:RTANNALARM_calc.INPA",16777215,0,"BSOC:BSY0:1:RTANNALARM_calc.INPA") #! Link("BSOC:BSY0:1:RTANNALARM_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb95.VAL") #! Field("BSOC:BSY0:1:RTANNALARM_calc.INPB",16777215,1,"BSOC:BSY0:1:RTANNALARM_calc.INPB") #! Field("BSOC:BSY0:1:RTANNALARM_calc.OUT",16777215,1,"BSOC:BSY0:1:RTANNALARM_calc.OUT") #! Link("BSOC:BSY0:1:RTANNALARM_calc.OUT","BSOC:BSY0:1:RTANNALARM.VAL") #! Record("BSOC:BSY0:1:RTANNALARM",500,20,0,0,"BSOC:BSY0:1:RTANNALARM") #! Field("BSOC:BSY0:1:RTANNALARM.VAL",16777215,1,"BSOC:BSY0:1:RTANNALARM.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi94") { field(DESC, "Port BSOIC_RD bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 94, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:BSY0:1:RTCASCO_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTCASCO_calc") { field(INPA, "PLC:BSY0:BC01:Bi94 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTCASCO PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTCASCO") { field(DESC, "BSOIC-HW_Cascade_Out") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb94",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb94") #! Field("PLC:BSY0:BC01:BSOIC_RDb94.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb94.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb94.FLNK","BSOC:BSY0:1:RTCASCO_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb94.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb94.VAL") #! Record("BSOC:BSY0:1:RTCASCO_calc",260,18,0,1,"BSOC:BSY0:1:RTCASCO_calc") #! Field("BSOC:BSY0:1:RTCASCO_calc.INPA",16777215,0,"BSOC:BSY0:1:RTCASCO_calc.INPA") #! Link("BSOC:BSY0:1:RTCASCO_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb94.VAL") #! Field("BSOC:BSY0:1:RTCASCO_calc.INPB",16777215,1,"BSOC:BSY0:1:RTCASCO_calc.INPB") #! Field("BSOC:BSY0:1:RTCASCO_calc.OUT",16777215,1,"BSOC:BSY0:1:RTCASCO_calc.OUT") #! Link("BSOC:BSY0:1:RTCASCO_calc.OUT","BSOC:BSY0:1:RTCASCO.VAL") #! Record("BSOC:BSY0:1:RTCASCO",500,20,0,0,"BSOC:BSY0:1:RTCASCO") #! Field("BSOC:BSY0:1:RTCASCO.VAL",16777215,1,"BSOC:BSY0:1:RTCASCO.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi93") { field(DESC, "Port BSOIC_RD bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTHWSO1_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWSO1_calc") { field(INPA, "PLC:BSY0:BC01:Bi93 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWSO1 PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWSO1") { field(DESC, "BSOIC-HW_Safety_Out1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb93",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb93") #! Field("PLC:BSY0:BC01:BSOIC_RDb93.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb93.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb93.FLNK","BSOC:BSY0:1:RTHWSO1_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb93.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb93.VAL") #! Record("BSOC:BSY0:1:RTHWSO1_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO1_calc") #! Field("BSOC:BSY0:1:RTHWSO1_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO1_calc.INPA") #! Link("BSOC:BSY0:1:RTHWSO1_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb93.VAL") #! Field("BSOC:BSY0:1:RTHWSO1_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO1_calc.INPB") #! Field("BSOC:BSY0:1:RTHWSO1_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO1_calc.OUT") #! Link("BSOC:BSY0:1:RTHWSO1_calc.OUT","BSOC:BSY0:1:RTHWSO1.VAL") #! Record("BSOC:BSY0:1:RTHWSO1",500,20,0,0,"BSOC:BSY0:1:RTHWSO1") #! Field("BSOC:BSY0:1:RTHWSO1.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO1.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi92") { field(DESC, "Port BSOIC_RD bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTHWSO2_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWSO2_calc") { field(INPA, "PLC:BSY0:BC01:Bi92 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWSO2 PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWSO2") { field(DESC, "BSOIC-HW_Safety_Out2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb92",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb92") #! Field("PLC:BSY0:BC01:BSOIC_RDb92.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb92.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb92.FLNK","BSOC:BSY0:1:RTHWSO2_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb92.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb92.VAL") #! Record("BSOC:BSY0:1:RTHWSO2_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO2_calc") #! Field("BSOC:BSY0:1:RTHWSO2_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO2_calc.INPA") #! Link("BSOC:BSY0:1:RTHWSO2_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb92.VAL") #! Field("BSOC:BSY0:1:RTHWSO2_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO2_calc.INPB") #! Field("BSOC:BSY0:1:RTHWSO2_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO2_calc.OUT") #! Link("BSOC:BSY0:1:RTHWSO2_calc.OUT","BSOC:BSY0:1:RTHWSO2.VAL") #! Record("BSOC:BSY0:1:RTHWSO2",500,20,0,0,"BSOC:BSY0:1:RTHWSO2") #! Field("BSOC:BSY0:1:RTHWSO2.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO2.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi91") { field(DESC, "Port BSOIC_RD bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTHWSO3_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWSO3_calc") { field(INPA, "PLC:BSY0:BC01:Bi91 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWSO3 PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWSO3") { field(DESC, "BSOIC-HW_Safety_Out3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb91",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb91") #! Field("PLC:BSY0:BC01:BSOIC_RDb91.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb91.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb91.FLNK","BSOC:BSY0:1:RTHWSO3_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb91.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb91.VAL") #! Record("BSOC:BSY0:1:RTHWSO3_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO3_calc") #! Field("BSOC:BSY0:1:RTHWSO3_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO3_calc.INPA") #! Link("BSOC:BSY0:1:RTHWSO3_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb91.VAL") #! Field("BSOC:BSY0:1:RTHWSO3_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO3_calc.INPB") #! Field("BSOC:BSY0:1:RTHWSO3_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO3_calc.OUT") #! Link("BSOC:BSY0:1:RTHWSO3_calc.OUT","BSOC:BSY0:1:RTHWSO3.VAL") #! Record("BSOC:BSY0:1:RTHWSO3",500,20,0,0,"BSOC:BSY0:1:RTHWSO3") #! Field("BSOC:BSY0:1:RTHWSO3.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO3.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi90") { field(DESC, "Port BSOIC_RD bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:RTHWSO4_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:RTHWSO4_calc") { field(INPA, "PLC:BSY0:BC01:Bi90 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:RTHWSO4 PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:RTHWSO4") { field(DESC, "BSOIC-HW_Safety_Out4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb90",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb90") #! Field("PLC:BSY0:BC01:BSOIC_RDb90.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb90.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb90.FLNK","BSOC:BSY0:1:RTHWSO4_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb90.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb90.VAL") #! Record("BSOC:BSY0:1:RTHWSO4_calc",260,18,0,1,"BSOC:BSY0:1:RTHWSO4_calc") #! Field("BSOC:BSY0:1:RTHWSO4_calc.INPA",16777215,0,"BSOC:BSY0:1:RTHWSO4_calc.INPA") #! Link("BSOC:BSY0:1:RTHWSO4_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb90.VAL") #! Field("BSOC:BSY0:1:RTHWSO4_calc.INPB",16777215,1,"BSOC:BSY0:1:RTHWSO4_calc.INPB") #! Field("BSOC:BSY0:1:RTHWSO4_calc.OUT",16777215,1,"BSOC:BSY0:1:RTHWSO4_calc.OUT") #! Link("BSOC:BSY0:1:RTHWSO4_calc.OUT","BSOC:BSY0:1:RTHWSO4.VAL") #! Record("BSOC:BSY0:1:RTHWSO4",500,20,0,0,"BSOC:BSY0:1:RTHWSO4") #! Field("BSOC:BSY0:1:RTHWSO4.VAL",16777215,1,"BSOC:BSY0:1:RTHWSO4.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi89") { field(DESC, "Port BSOIC_RD bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:LATEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:LATEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi89 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:LATEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:LATEQP") { field(DESC, "BSOIC-LAT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb89",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb89") #! Field("PLC:BSY0:BC01:BSOIC_RDb89.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb89.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb89.FLNK","BSOC:BSY0:1:LATEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb89.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb89.VAL") #! Record("BSOC:BSY0:1:LATEQP_calc",260,18,0,1,"BSOC:BSY0:1:LATEQP_calc") #! Field("BSOC:BSY0:1:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:1:LATEQP_calc.INPA") #! Link("BSOC:BSY0:1:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb89.VAL") #! Field("BSOC:BSY0:1:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:1:LATEQP_calc.INPB") #! Field("BSOC:BSY0:1:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:1:LATEQP_calc.OUT") #! Link("BSOC:BSY0:1:LATEQP_calc.OUT","BSOC:BSY0:1:LATEQP.VAL") #! Record("BSOC:BSY0:1:LATEQP",500,20,0,0,"BSOC:BSY0:1:LATEQP") #! Field("BSOC:BSY0:1:LATEQP.VAL",16777215,1,"BSOC:BSY0:1:LATEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi88") { field(DESC, "Port BSOIC_RD bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:LATRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:LATRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi88 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:LATRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:LATRAD") { field(DESC, "BSOIC-LAT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb88",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb88") #! Field("PLC:BSY0:BC01:BSOIC_RDb88.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb88.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb88.FLNK","BSOC:BSY0:1:LATRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb88.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb88.VAL") #! Record("BSOC:BSY0:1:LATRAD_calc",260,18,0,1,"BSOC:BSY0:1:LATRAD_calc") #! Field("BSOC:BSY0:1:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:1:LATRAD_calc.INPA") #! Link("BSOC:BSY0:1:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb88.VAL") #! Field("BSOC:BSY0:1:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:1:LATRAD_calc.INPB") #! Field("BSOC:BSY0:1:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:1:LATRAD_calc.OUT") #! Link("BSOC:BSY0:1:LATRAD_calc.OUT","BSOC:BSY0:1:LATRAD.VAL") #! Record("BSOC:BSY0:1:LATRAD",500,20,0,0,"BSOC:BSY0:1:LATRAD") #! Field("BSOC:BSY0:1:LATRAD.VAL",16777215,1,"BSOC:BSY0:1:LATRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi103") { field(DESC, "Port BSOIC_RD bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:3:LATEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:LATEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi103 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:LATEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:LATEQP") { field(DESC, "BSOIC-LAT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb103",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb103") #! Field("PLC:BSY0:BC01:BSOIC_RDb103.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb103.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb103.FLNK","BSOC:BSY0:3:LATEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb103.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb103.VAL") #! Record("BSOC:BSY0:3:LATEQP_calc",260,18,0,1,"BSOC:BSY0:3:LATEQP_calc") #! Field("BSOC:BSY0:3:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:3:LATEQP_calc.INPA") #! Link("BSOC:BSY0:3:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb103.VAL") #! Field("BSOC:BSY0:3:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:3:LATEQP_calc.INPB") #! Field("BSOC:BSY0:3:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:3:LATEQP_calc.OUT") #! Link("BSOC:BSY0:3:LATEQP_calc.OUT","BSOC:BSY0:3:LATEQP.VAL") #! Record("BSOC:BSY0:3:LATEQP",500,20,0,0,"BSOC:BSY0:3:LATEQP") #! Field("BSOC:BSY0:3:LATEQP.VAL",16777215,1,"BSOC:BSY0:3:LATEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi102") { field(DESC, "Port BSOIC_RD bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:3:LATRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:LATRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi102 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:LATRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:LATRAD") { field(DESC, "BSOIC-LAT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb102",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb102") #! Field("PLC:BSY0:BC01:BSOIC_RDb102.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb102.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb102.FLNK","BSOC:BSY0:3:LATRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb102.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb102.VAL") #! Record("BSOC:BSY0:3:LATRAD_calc",260,18,0,1,"BSOC:BSY0:3:LATRAD_calc") #! Field("BSOC:BSY0:3:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:3:LATRAD_calc.INPA") #! Link("BSOC:BSY0:3:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb102.VAL") #! Field("BSOC:BSY0:3:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:3:LATRAD_calc.INPB") #! Field("BSOC:BSY0:3:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:3:LATRAD_calc.OUT") #! Link("BSOC:BSY0:3:LATRAD_calc.OUT","BSOC:BSY0:3:LATRAD.VAL") #! Record("BSOC:BSY0:3:LATRAD",500,20,0,0,"BSOC:BSY0:3:LATRAD") #! Field("BSOC:BSY0:3:LATRAD.VAL",16777215,1,"BSOC:BSY0:3:LATRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi101") { field(DESC, "Port BSOIC_RD bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:4:LATEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:LATEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi101 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:LATEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:LATEQP") { field(DESC, "BSOIC-LAT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb101",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb101") #! Field("PLC:BSY0:BC01:BSOIC_RDb101.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb101.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb101.FLNK","BSOC:BSY0:4:LATEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb101.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb101.VAL") #! Record("BSOC:BSY0:4:LATEQP_calc",260,18,0,1,"BSOC:BSY0:4:LATEQP_calc") #! Field("BSOC:BSY0:4:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:4:LATEQP_calc.INPA") #! Link("BSOC:BSY0:4:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb101.VAL") #! Field("BSOC:BSY0:4:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:4:LATEQP_calc.INPB") #! Field("BSOC:BSY0:4:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:4:LATEQP_calc.OUT") #! Link("BSOC:BSY0:4:LATEQP_calc.OUT","BSOC:BSY0:4:LATEQP.VAL") #! Record("BSOC:BSY0:4:LATEQP",500,20,0,0,"BSOC:BSY0:4:LATEQP") #! Field("BSOC:BSY0:4:LATEQP.VAL",16777215,1,"BSOC:BSY0:4:LATEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi100") { field(DESC, "Port BSOIC_RD bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:4:LATRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:LATRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi100 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:LATRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:LATRAD") { field(DESC, "BSOIC-LAT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb100",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb100") #! Field("PLC:BSY0:BC01:BSOIC_RDb100.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb100.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb100.FLNK","BSOC:BSY0:4:LATRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb100.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb100.VAL") #! Record("BSOC:BSY0:4:LATRAD_calc",260,18,0,1,"BSOC:BSY0:4:LATRAD_calc") #! Field("BSOC:BSY0:4:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:4:LATRAD_calc.INPA") #! Link("BSOC:BSY0:4:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb100.VAL") #! Field("BSOC:BSY0:4:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:4:LATRAD_calc.INPB") #! Field("BSOC:BSY0:4:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:4:LATRAD_calc.OUT") #! Link("BSOC:BSY0:4:LATRAD_calc.OUT","BSOC:BSY0:4:LATRAD.VAL") #! Record("BSOC:BSY0:4:LATRAD",500,20,0,0,"BSOC:BSY0:4:LATRAD") #! Field("BSOC:BSY0:4:LATRAD.VAL",16777215,1,"BSOC:BSY0:4:LATRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi99") { field(DESC, "Port BSOIC_RD bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:5:LATEQP_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:LATEQP_calc") { field(INPA, "PLC:BSY0:BC01:Bi99 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:LATEQP PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:LATEQP") { field(DESC, "BSOIC-LAT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb99",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb99") #! Field("PLC:BSY0:BC01:BSOIC_RDb99.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb99.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb99.FLNK","BSOC:BSY0:5:LATEQP_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb99.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb99.VAL") #! Record("BSOC:BSY0:5:LATEQP_calc",260,18,0,1,"BSOC:BSY0:5:LATEQP_calc") #! Field("BSOC:BSY0:5:LATEQP_calc.INPA",16777215,0,"BSOC:BSY0:5:LATEQP_calc.INPA") #! Link("BSOC:BSY0:5:LATEQP_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb99.VAL") #! Field("BSOC:BSY0:5:LATEQP_calc.INPB",16777215,1,"BSOC:BSY0:5:LATEQP_calc.INPB") #! Field("BSOC:BSY0:5:LATEQP_calc.OUT",16777215,1,"BSOC:BSY0:5:LATEQP_calc.OUT") #! Link("BSOC:BSY0:5:LATEQP_calc.OUT","BSOC:BSY0:5:LATEQP.VAL") #! Record("BSOC:BSY0:5:LATEQP",500,20,0,0,"BSOC:BSY0:5:LATEQP") #! Field("BSOC:BSY0:5:LATEQP.VAL",16777215,1,"BSOC:BSY0:5:LATEQP.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi98") { field(DESC, "Port BSOIC_RD bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:5:LATRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:LATRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi98 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:LATRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:LATRAD") { field(DESC, "BSOIC-LAT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb98",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb98") #! Field("PLC:BSY0:BC01:BSOIC_RDb98.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb98.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb98.FLNK","BSOC:BSY0:5:LATRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb98.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb98.VAL") #! Record("BSOC:BSY0:5:LATRAD_calc",260,18,0,1,"BSOC:BSY0:5:LATRAD_calc") #! Field("BSOC:BSY0:5:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:5:LATRAD_calc.INPA") #! Link("BSOC:BSY0:5:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb98.VAL") #! Field("BSOC:BSY0:5:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:5:LATRAD_calc.INPB") #! Field("BSOC:BSY0:5:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:5:LATRAD_calc.OUT") #! Link("BSOC:BSY0:5:LATRAD_calc.OUT","BSOC:BSY0:5:LATRAD.VAL") #! Record("BSOC:BSY0:5:LATRAD",500,20,0,0,"BSOC:BSY0:5:LATRAD") #! Field("BSOC:BSY0:5:LATRAD.VAL",16777215,1,"BSOC:BSY0:5:LATRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi97") { field(DESC, "Port BSOIC_RD bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:2:LATRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:2:LATRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi97 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:2:LATRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:2:LATRAD") { field(DESC, "BSOIC-LAT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb97",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb97") #! Field("PLC:BSY0:BC01:BSOIC_RDb97.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb97.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb97.FLNK","BSOC:BSY0:2:LATRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb97.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb97.VAL") #! Record("BSOC:BSY0:2:LATRAD_calc",260,18,0,1,"BSOC:BSY0:2:LATRAD_calc") #! Field("BSOC:BSY0:2:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:2:LATRAD_calc.INPA") #! Link("BSOC:BSY0:2:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb97.VAL") #! Field("BSOC:BSY0:2:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:2:LATRAD_calc.INPB") #! Field("BSOC:BSY0:2:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:2:LATRAD_calc.OUT") #! Link("BSOC:BSY0:2:LATRAD_calc.OUT","BSOC:BSY0:2:LATRAD.VAL") #! Record("BSOC:BSY0:2:LATRAD",500,20,0,0,"BSOC:BSY0:2:LATRAD") #! Field("BSOC:BSY0:2:LATRAD.VAL",16777215,1,"BSOC:BSY0:2:LATRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi96") { field(DESC, "Port BSOIC_RD bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:6:LATRAD_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:6:LATRAD_calc") { field(INPA, "PLC:BSY0:BC01:Bi96 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:6:LATRAD PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:6:LATRAD") { field(DESC, "BSOIC-LAT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb96",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb96") #! Field("PLC:BSY0:BC01:BSOIC_RDb96.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb96.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb96.FLNK","BSOC:BSY0:6:LATRAD_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb96.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb96.VAL") #! Record("BSOC:BSY0:6:LATRAD_calc",260,18,0,1,"BSOC:BSY0:6:LATRAD_calc") #! Field("BSOC:BSY0:6:LATRAD_calc.INPA",16777215,0,"BSOC:BSY0:6:LATRAD_calc.INPA") #! Link("BSOC:BSY0:6:LATRAD_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb96.VAL") #! Field("BSOC:BSY0:6:LATRAD_calc.INPB",16777215,1,"BSOC:BSY0:6:LATRAD_calc.INPB") #! Field("BSOC:BSY0:6:LATRAD_calc.OUT",16777215,1,"BSOC:BSY0:6:LATRAD_calc.OUT") #! Link("BSOC:BSY0:6:LATRAD_calc.OUT","BSOC:BSY0:6:LATRAD.VAL") #! Record("BSOC:BSY0:6:LATRAD",500,20,0,0,"BSOC:BSY0:6:LATRAD") #! Field("BSOC:BSY0:6:LATRAD.VAL",16777215,1,"BSOC:BSY0:6:LATRAD.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi111") { field(DESC, "Port BSOIC_RD bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:LATCASCI_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:LATCASCI_calc") { field(INPA, "PLC:BSY0:BC01:Bi111 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:LATCASCI PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:LATCASCI") { field(DESC, "BSOIC-LAT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb111",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb111") #! Field("PLC:BSY0:BC01:BSOIC_RDb111.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb111.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb111.FLNK","BSOC:BSY0:1:LATCASCI_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb111.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb111.VAL") #! Record("BSOC:BSY0:1:LATCASCI_calc",260,18,0,1,"BSOC:BSY0:1:LATCASCI_calc") #! Field("BSOC:BSY0:1:LATCASCI_calc.INPA",16777215,0,"BSOC:BSY0:1:LATCASCI_calc.INPA") #! Link("BSOC:BSY0:1:LATCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb111.VAL") #! Field("BSOC:BSY0:1:LATCASCI_calc.INPB",16777215,1,"BSOC:BSY0:1:LATCASCI_calc.INPB") #! Field("BSOC:BSY0:1:LATCASCI_calc.OUT",16777215,1,"BSOC:BSY0:1:LATCASCI_calc.OUT") #! Link("BSOC:BSY0:1:LATCASCI_calc.OUT","BSOC:BSY0:1:LATCASCI.VAL") #! Record("BSOC:BSY0:1:LATCASCI",500,20,0,0,"BSOC:BSY0:1:LATCASCI") #! Field("BSOC:BSY0:1:LATCASCI.VAL",16777215,1,"BSOC:BSY0:1:LATCASCI.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi110") { field(DESC, "Port BSOIC_RD bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:2:LATCASCI_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:2:LATCASCI_calc") { field(INPA, "PLC:BSY0:BC01:Bi110 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:2:LATCASCI PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:2:LATCASCI") { field(DESC, "BSOIC-LAT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb110",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb110") #! Field("PLC:BSY0:BC01:BSOIC_RDb110.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb110.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb110.FLNK","BSOC:BSY0:2:LATCASCI_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb110.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb110.VAL") #! Record("BSOC:BSY0:2:LATCASCI_calc",260,18,0,1,"BSOC:BSY0:2:LATCASCI_calc") #! Field("BSOC:BSY0:2:LATCASCI_calc.INPA",16777215,0,"BSOC:BSY0:2:LATCASCI_calc.INPA") #! Link("BSOC:BSY0:2:LATCASCI_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb110.VAL") #! Field("BSOC:BSY0:2:LATCASCI_calc.INPB",16777215,1,"BSOC:BSY0:2:LATCASCI_calc.INPB") #! Field("BSOC:BSY0:2:LATCASCI_calc.OUT",16777215,1,"BSOC:BSY0:2:LATCASCI_calc.OUT") #! Link("BSOC:BSY0:2:LATCASCI_calc.OUT","BSOC:BSY0:2:LATCASCI.VAL") #! Record("BSOC:BSY0:2:LATCASCI",500,20,0,0,"BSOC:BSY0:2:LATCASCI") #! Field("BSOC:BSY0:2:LATCASCI.VAL",16777215,1,"BSOC:BSY0:2:LATCASCI.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi109") { field(DESC, "Port BSOIC_RD bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:ALLGOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:ALLGOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi109 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:ALLGOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:ALLGOK") { field(DESC, "BSOIC-All_Gamma_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb109",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb109") #! Field("PLC:BSY0:BC01:BSOIC_RDb109.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb109.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb109.FLNK","BSOC:BSY0:1:ALLGOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb109.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb109.VAL") #! Record("BSOC:BSY0:1:ALLGOK_calc",260,18,0,1,"BSOC:BSY0:1:ALLGOK_calc") #! Field("BSOC:BSY0:1:ALLGOK_calc.INPA",16777215,0,"BSOC:BSY0:1:ALLGOK_calc.INPA") #! Link("BSOC:BSY0:1:ALLGOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb109.VAL") #! Field("BSOC:BSY0:1:ALLGOK_calc.INPB",16777215,1,"BSOC:BSY0:1:ALLGOK_calc.INPB") #! Field("BSOC:BSY0:1:ALLGOK_calc.OUT",16777215,1,"BSOC:BSY0:1:ALLGOK_calc.OUT") #! Link("BSOC:BSY0:1:ALLGOK_calc.OUT","BSOC:BSY0:1:ALLGOK.VAL") #! Record("BSOC:BSY0:1:ALLGOK",500,20,0,0,"BSOC:BSY0:1:ALLGOK") #! Field("BSOC:BSY0:1:ALLGOK.VAL",16777215,1,"BSOC:BSY0:1:ALLGOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi108") { field(DESC, "Port BSOIC_RD bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 108, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:ALLNOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:ALLNOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi108 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:ALLNOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:ALLNOK") { field(DESC, "BSOIC-All_Neutron_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb108",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb108") #! Field("PLC:BSY0:BC01:BSOIC_RDb108.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb108.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb108.FLNK","BSOC:BSY0:1:ALLNOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb108.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb108.VAL") #! Record("BSOC:BSY0:1:ALLNOK_calc",260,18,0,1,"BSOC:BSY0:1:ALLNOK_calc") #! Field("BSOC:BSY0:1:ALLNOK_calc.INPA",16777215,0,"BSOC:BSY0:1:ALLNOK_calc.INPA") #! Link("BSOC:BSY0:1:ALLNOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb108.VAL") #! Field("BSOC:BSY0:1:ALLNOK_calc.INPB",16777215,1,"BSOC:BSY0:1:ALLNOK_calc.INPB") #! Field("BSOC:BSY0:1:ALLNOK_calc.OUT",16777215,1,"BSOC:BSY0:1:ALLNOK_calc.OUT") #! Link("BSOC:BSY0:1:ALLNOK_calc.OUT","BSOC:BSY0:1:ALLNOK.VAL") #! Record("BSOC:BSY0:1:ALLNOK",500,20,0,0,"BSOC:BSY0:1:ALLNOK") #! Field("BSOC:BSY0:1:ALLNOK.VAL",16777215,1,"BSOC:BSY0:1:ALLNOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi107") { field(DESC, "Port BSOIC_RD bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:ALLOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:ALLOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi107 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:ALLOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:ALLOK") { field(DESC, "BSOIC-All_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb107",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb107") #! Field("PLC:BSY0:BC01:BSOIC_RDb107.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb107.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb107.FLNK","BSOC:BSY0:1:ALLOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb107.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb107.VAL") #! Record("BSOC:BSY0:1:ALLOK_calc",260,18,0,1,"BSOC:BSY0:1:ALLOK_calc") #! Field("BSOC:BSY0:1:ALLOK_calc.INPA",16777215,0,"BSOC:BSY0:1:ALLOK_calc.INPA") #! Link("BSOC:BSY0:1:ALLOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb107.VAL") #! Field("BSOC:BSY0:1:ALLOK_calc.INPB",16777215,1,"BSOC:BSY0:1:ALLOK_calc.INPB") #! Field("BSOC:BSY0:1:ALLOK_calc.OUT",16777215,1,"BSOC:BSY0:1:ALLOK_calc.OUT") #! Link("BSOC:BSY0:1:ALLOK_calc.OUT","BSOC:BSY0:1:ALLOK.VAL") #! Record("BSOC:BSY0:1:ALLOK",500,20,0,0,"BSOC:BSY0:1:ALLOK") #! Field("BSOC:BSY0:1:ALLOK.VAL",16777215,1,"BSOC:BSY0:1:ALLOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi106") { field(DESC, "Port BSOIC_RD bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 106, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:BSY0:1:EQPWARN_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:EQPWARN_calc") { field(INPA, "PLC:BSY0:BC01:Bi106 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:EQPWARN PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:EQPWARN") { field(DESC, "BSOIC-Equip_Warn_G1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb106",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb106") #! Field("PLC:BSY0:BC01:BSOIC_RDb106.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb106.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb106.FLNK","BSOC:BSY0:1:EQPWARN_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb106.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb106.VAL") #! Record("BSOC:BSY0:1:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:1:EQPWARN_calc") #! Field("BSOC:BSY0:1:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:1:EQPWARN_calc.INPA") #! Link("BSOC:BSY0:1:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb106.VAL") #! Field("BSOC:BSY0:1:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:1:EQPWARN_calc.INPB") #! Field("BSOC:BSY0:1:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:1:EQPWARN_calc.OUT") #! Link("BSOC:BSY0:1:EQPWARN_calc.OUT","BSOC:BSY0:1:EQPWARN.VAL") #! Record("BSOC:BSY0:1:EQPWARN",500,20,0,0,"BSOC:BSY0:1:EQPWARN") #! Field("BSOC:BSY0:1:EQPWARN.VAL",16777215,1,"BSOC:BSY0:1:EQPWARN.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi105") { field(DESC, "Port BSOIC_RD bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 105, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:BSY0:3:EQPWARN_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:EQPWARN_calc") { field(INPA, "PLC:BSY0:BC01:Bi105 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:EQPWARN PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:EQPWARN") { field(DESC, "BSOIC-Equip_Warn_G2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb105",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb105") #! Field("PLC:BSY0:BC01:BSOIC_RDb105.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb105.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb105.FLNK","BSOC:BSY0:3:EQPWARN_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb105.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb105.VAL") #! Record("BSOC:BSY0:3:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:3:EQPWARN_calc") #! Field("BSOC:BSY0:3:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:3:EQPWARN_calc.INPA") #! Link("BSOC:BSY0:3:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb105.VAL") #! Field("BSOC:BSY0:3:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:3:EQPWARN_calc.INPB") #! Field("BSOC:BSY0:3:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:3:EQPWARN_calc.OUT") #! Link("BSOC:BSY0:3:EQPWARN_calc.OUT","BSOC:BSY0:3:EQPWARN.VAL") #! Record("BSOC:BSY0:3:EQPWARN",500,20,0,0,"BSOC:BSY0:3:EQPWARN") #! Field("BSOC:BSY0:3:EQPWARN.VAL",16777215,1,"BSOC:BSY0:3:EQPWARN.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi104") { field(DESC, "Port BSOIC_RD bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 104, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:BSY0:4:EQPWARN_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:EQPWARN_calc") { field(INPA, "PLC:BSY0:BC01:Bi104 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:EQPWARN PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:EQPWARN") { field(DESC, "BSOIC-Equip_Warn_G3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb104",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb104") #! Field("PLC:BSY0:BC01:BSOIC_RDb104.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb104.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb104.FLNK","BSOC:BSY0:4:EQPWARN_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb104.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb104.VAL") #! Record("BSOC:BSY0:4:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:4:EQPWARN_calc") #! Field("BSOC:BSY0:4:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:4:EQPWARN_calc.INPA") #! Link("BSOC:BSY0:4:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb104.VAL") #! Field("BSOC:BSY0:4:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:4:EQPWARN_calc.INPB") #! Field("BSOC:BSY0:4:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:4:EQPWARN_calc.OUT") #! Link("BSOC:BSY0:4:EQPWARN_calc.OUT","BSOC:BSY0:4:EQPWARN.VAL") #! Record("BSOC:BSY0:4:EQPWARN",500,20,0,0,"BSOC:BSY0:4:EQPWARN") #! Field("BSOC:BSY0:4:EQPWARN.VAL",16777215,1,"BSOC:BSY0:4:EQPWARN.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi119") { field(DESC, "Port BSOIC_RD bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 119, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:BSY0:5:EQPWARN_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:EQPWARN_calc") { field(INPA, "PLC:BSY0:BC01:Bi119 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:EQPWARN PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:EQPWARN") { field(DESC, "BSOIC-Equip_Warn_G4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb119",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb119") #! Field("PLC:BSY0:BC01:BSOIC_RDb119.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb119.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb119.FLNK","BSOC:BSY0:5:EQPWARN_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb119.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb119.VAL") #! Record("BSOC:BSY0:5:EQPWARN_calc",260,18,0,1,"BSOC:BSY0:5:EQPWARN_calc") #! Field("BSOC:BSY0:5:EQPWARN_calc.INPA",16777215,0,"BSOC:BSY0:5:EQPWARN_calc.INPA") #! Link("BSOC:BSY0:5:EQPWARN_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb119.VAL") #! Field("BSOC:BSY0:5:EQPWARN_calc.INPB",16777215,1,"BSOC:BSY0:5:EQPWARN_calc.INPB") #! Field("BSOC:BSY0:5:EQPWARN_calc.OUT",16777215,1,"BSOC:BSY0:5:EQPWARN_calc.OUT") #! Link("BSOC:BSY0:5:EQPWARN_calc.OUT","BSOC:BSY0:5:EQPWARN.VAL") #! Record("BSOC:BSY0:5:EQPWARN",500,20,0,0,"BSOC:BSY0:5:EQPWARN") #! Field("BSOC:BSY0:5:EQPWARN.VAL",16777215,1,"BSOC:BSY0:5:EQPWARN.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi117") { field(DESC, "Port BSOIC_RD bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 117, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:BSY0:1:PLCHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:PLCHB_calc") { field(INPA, "PLC:BSY0:BC01:Bi117 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:PLCHB PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:PLCHB") { field(DESC, "BSOIC-PLC_Heartbeat") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb117",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb117") #! Field("PLC:BSY0:BC01:BSOIC_RDb117.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb117.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb117.FLNK","BSOC:BSY0:1:PLCHB_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb117.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb117.VAL") #! Record("BSOC:BSY0:1:PLCHB_calc",260,18,0,1,"BSOC:BSY0:1:PLCHB_calc") #! Field("BSOC:BSY0:1:PLCHB_calc.INPA",16777215,0,"BSOC:BSY0:1:PLCHB_calc.INPA") #! Link("BSOC:BSY0:1:PLCHB_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb117.VAL") #! Field("BSOC:BSY0:1:PLCHB_calc.INPB",16777215,1,"BSOC:BSY0:1:PLCHB_calc.INPB") #! Field("BSOC:BSY0:1:PLCHB_calc.OUT",16777215,1,"BSOC:BSY0:1:PLCHB_calc.OUT") #! Link("BSOC:BSY0:1:PLCHB_calc.OUT","BSOC:BSY0:1:PLCHB.VAL") #! Record("BSOC:BSY0:1:PLCHB",500,20,0,0,"BSOC:BSY0:1:PLCHB") #! Field("BSOC:BSY0:1:PLCHB.VAL",16777215,1,"BSOC:BSY0:1:PLCHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi116") { field(DESC, "Port BSOIC_RD bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 116, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:1:CHOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:1:CHOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi116 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:1:CHOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:1:CHOK") { field(DESC, "BSOIC-CH1_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb116",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb116") #! Field("PLC:BSY0:BC01:BSOIC_RDb116.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb116.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb116.FLNK","BSOC:BSY0:1:CHOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb116.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb116.VAL") #! Record("BSOC:BSY0:1:CHOK_calc",260,18,0,1,"BSOC:BSY0:1:CHOK_calc") #! Field("BSOC:BSY0:1:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:1:CHOK_calc.INPA") #! Link("BSOC:BSY0:1:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb116.VAL") #! Field("BSOC:BSY0:1:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:1:CHOK_calc.INPB") #! Field("BSOC:BSY0:1:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:1:CHOK_calc.OUT") #! Link("BSOC:BSY0:1:CHOK_calc.OUT","BSOC:BSY0:1:CHOK.VAL") #! Record("BSOC:BSY0:1:CHOK",500,20,0,0,"BSOC:BSY0:1:CHOK") #! Field("BSOC:BSY0:1:CHOK.VAL",16777215,1,"BSOC:BSY0:1:CHOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi115") { field(DESC, "Port BSOIC_RD bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 115, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:2:CHOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:2:CHOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi115 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:2:CHOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:2:CHOK") { field(DESC, "BSOIC-CH2_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb115",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb115") #! Field("PLC:BSY0:BC01:BSOIC_RDb115.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb115.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb115.FLNK","BSOC:BSY0:2:CHOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb115.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb115.VAL") #! Record("BSOC:BSY0:2:CHOK_calc",260,18,0,1,"BSOC:BSY0:2:CHOK_calc") #! Field("BSOC:BSY0:2:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:2:CHOK_calc.INPA") #! Link("BSOC:BSY0:2:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb115.VAL") #! Field("BSOC:BSY0:2:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:2:CHOK_calc.INPB") #! Field("BSOC:BSY0:2:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:2:CHOK_calc.OUT") #! Link("BSOC:BSY0:2:CHOK_calc.OUT","BSOC:BSY0:2:CHOK.VAL") #! Record("BSOC:BSY0:2:CHOK",500,20,0,0,"BSOC:BSY0:2:CHOK") #! Field("BSOC:BSY0:2:CHOK.VAL",16777215,1,"BSOC:BSY0:2:CHOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi114") { field(DESC, "Port BSOIC_RD bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 114, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:3:CHOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:3:CHOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi114 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:3:CHOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:3:CHOK") { field(DESC, "BSOIC-CH3_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb114",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb114") #! Field("PLC:BSY0:BC01:BSOIC_RDb114.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb114.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb114.FLNK","BSOC:BSY0:3:CHOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb114.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb114.VAL") #! Record("BSOC:BSY0:3:CHOK_calc",260,18,0,1,"BSOC:BSY0:3:CHOK_calc") #! Field("BSOC:BSY0:3:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:3:CHOK_calc.INPA") #! Link("BSOC:BSY0:3:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb114.VAL") #! Field("BSOC:BSY0:3:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:3:CHOK_calc.INPB") #! Field("BSOC:BSY0:3:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:3:CHOK_calc.OUT") #! Link("BSOC:BSY0:3:CHOK_calc.OUT","BSOC:BSY0:3:CHOK.VAL") #! Record("BSOC:BSY0:3:CHOK",500,20,0,0,"BSOC:BSY0:3:CHOK") #! Field("BSOC:BSY0:3:CHOK.VAL",16777215,1,"BSOC:BSY0:3:CHOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi113") { field(DESC, "Port BSOIC_RD bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 113, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:4:CHOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:4:CHOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi113 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:4:CHOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:4:CHOK") { field(DESC, "BSOIC-CH4_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb113",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb113") #! Field("PLC:BSY0:BC01:BSOIC_RDb113.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb113.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb113.FLNK","BSOC:BSY0:4:CHOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb113.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb113.VAL") #! Record("BSOC:BSY0:4:CHOK_calc",260,18,0,1,"BSOC:BSY0:4:CHOK_calc") #! Field("BSOC:BSY0:4:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:4:CHOK_calc.INPA") #! Link("BSOC:BSY0:4:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb113.VAL") #! Field("BSOC:BSY0:4:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:4:CHOK_calc.INPB") #! Field("BSOC:BSY0:4:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:4:CHOK_calc.OUT") #! Link("BSOC:BSY0:4:CHOK_calc.OUT","BSOC:BSY0:4:CHOK.VAL") #! Record("BSOC:BSY0:4:CHOK",500,20,0,0,"BSOC:BSY0:4:CHOK") #! Field("BSOC:BSY0:4:CHOK.VAL",16777215,1,"BSOC:BSY0:4:CHOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi112") { field(DESC, "Port BSOIC_RD bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 112, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:5:CHOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:5:CHOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi112 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:5:CHOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:5:CHOK") { field(DESC, "BSOIC-CH5_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb112",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb112") #! Field("PLC:BSY0:BC01:BSOIC_RDb112.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb112.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb112.FLNK","BSOC:BSY0:5:CHOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb112.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb112.VAL") #! Record("BSOC:BSY0:5:CHOK_calc",260,18,0,1,"BSOC:BSY0:5:CHOK_calc") #! Field("BSOC:BSY0:5:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:5:CHOK_calc.INPA") #! Link("BSOC:BSY0:5:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb112.VAL") #! Field("BSOC:BSY0:5:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:5:CHOK_calc.INPB") #! Field("BSOC:BSY0:5:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:5:CHOK_calc.OUT") #! Link("BSOC:BSY0:5:CHOK_calc.OUT","BSOC:BSY0:5:CHOK.VAL") #! Record("BSOC:BSY0:5:CHOK",500,20,0,0,"BSOC:BSY0:5:CHOK") #! Field("BSOC:BSY0:5:CHOK.VAL",16777215,1,"BSOC:BSY0:5:CHOK.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:BC01:Bi127") { field(DESC, "Port BSOIC_RD bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 127, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:BSY0:6:CHOK_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:BSY0:6:CHOK_calc") { field(INPA, "PLC:BSY0:BC01:Bi127 NPP MS") field(INPB, "PLC:BSY0:BC01:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:BSY0:6:CHOK PP MS") field(ASG, "Internal") } record(bi, "BSOC:BSY0:6:CHOK") { field(DESC, "BSOIC-CH6_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:BC01:BSOIC_RDb127",20,19,0,0,"PLC:BSY0:BC01:BSOIC_RDb127") #! Field("PLC:BSY0:BC01:BSOIC_RDb127.FLNK",16777215,1,"PLC:BSY0:BC01:BSOIC_RDb127.FLNK") #! Link("PLC:BSY0:BC01:BSOIC_RDb127.FLNK","BSOC:BSY0:6:CHOK_calc") #! Field("PLC:BSY0:BC01:BSOIC_RDb127.VAL",16777215,0,"PLC:BSY0:BC01:BSOIC_RDb127.VAL") #! Record("BSOC:BSY0:6:CHOK_calc",260,18,0,1,"BSOC:BSY0:6:CHOK_calc") #! Field("BSOC:BSY0:6:CHOK_calc.INPA",16777215,0,"BSOC:BSY0:6:CHOK_calc.INPA") #! Link("BSOC:BSY0:6:CHOK_calc.INPA","PLC:BSY0:BC01:BSOIC_RDb127.VAL") #! Field("BSOC:BSY0:6:CHOK_calc.INPB",16777215,1,"BSOC:BSY0:6:CHOK_calc.INPB") #! Field("BSOC:BSY0:6:CHOK_calc.OUT",16777215,1,"BSOC:BSY0:6:CHOK_calc.OUT") #! Link("BSOC:BSY0:6:CHOK_calc.OUT","BSOC:BSY0:6:CHOK.VAL") #! Record("BSOC:BSY0:6:CHOK",500,20,0,0,"BSOC:BSY0:6:CHOK") #! Field("BSOC:BSY0:6:CHOK.VAL",16777215,1,"BSOC:BSY0:6:CHOK.VAL") record(bo, "BSOC:BSY0:1:SRESET") { field(DESC, "BSOIC-Soft_Reset_G1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:3:SRESET") { field(DESC, "BSOIC-Soft_Reset_G2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:4:SRESET") { field(DESC, "BSOIC-Soft_Reset_G3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 5, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:5:SRESET") { field(DESC, "BSOIC-Soft_Reset_G4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 4, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:2:SRESET") { field(DESC, "BSOIC-Soft_Reset_N1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:6:SRESET") { field(DESC, "BSOIC-Soft_Reset_N2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 2, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:1:SRESET_ALL") { field(DESC, "BSOIC-Soft_Reset_All") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 1, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "BSOC:BSY0:1:SPAUSEHB") { field(DESC, "BSOIC-Soft_Pause_Hb") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Pause") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:BC01:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:BC01:TABLE_CYCLER") { field( OUT, "PLC:BSY0:BC01:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:BC01:SEG_CYCLER") { field( OUT, "PLC:BSY0:BC01:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:BC01:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:BC01:REQ_TABLE CP") field( INPB, "PLC:BSY0:BC01:REQ_SEG CP") field( INPC, "PLC:BSY0:BC01:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:BC01:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:BC01:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:BC01:REQ_TABLE CP") field( INPB, "PLC:BSY0:BC01:REQ_SEG CP") field( INPC, "PLC:BSY0:BC01:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:BC01:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:BC01:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:BC01:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:BC01:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:BC01:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:BC01:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:BC01:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:BC01:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:BC01:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:BC01:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:BC01:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:BC01:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:BC01:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:BC01:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:BC01:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:BC01:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:BC01:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:BC01:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:BC01:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:BC01:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:BC01:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:BC01:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:BC01:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:BC01:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:BC01:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:BC01:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:BC01:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:BC01:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:BC01:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:BC01:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:BC01:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:BC01:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:BC01:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:BC01:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:BC01:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:BC01:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT1 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT2 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT3 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT4 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT5 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT6 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:BC01:REQ_SEG_OUT") field(INPB, "PLC:BSY0:BC01:SEG_BIT7 MS") field(INPC, "PLC:BSY0:BC01:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:BC01:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:BC01:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:BC01:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:BC01:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:BC01:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:BC01:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:BC01:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:BC01:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:BC01:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:BC01:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:BC01:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:BC01:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:BC01:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:BC01:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_RD, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:BC01:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(BSOIC_WRT, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:BC01:w0") { field(DESC, "Checksum word 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:w1") { field(DESC, "Checksum word 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:BC01:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:BC01:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:BC01:w3") { field(DESC, "Checksum word 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:BC01:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:BC01:w3 PP MS") field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:BC01:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:BC01:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:BC01:w4") { field(DESC, "Checksum word 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:BC01:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:BC01:w4 NPP MS") field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:BC01:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:BC01:w5") { field(DESC, "Checksum word 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:BC01:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:BC01:w5 NPP MS") field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:BC01:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:BC01:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:BC01:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:BC01:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:BC01:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:BC01:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:BC01:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:BC01:w6 NPP MS") field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:BC01:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:BC01:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:BC01:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:BC01:w7 NPP MS") field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:BC01:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(BSOIC_WD, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:BC01:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:BC01:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:BC01:w8 NPP MS") field(INPB, "PLC:BSY0:BC01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:BC01:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:BC01:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:BC01:OP_HOURS") { field(INPA, "PLC:BSY0:BC01:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:BC01:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:BC01:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:BC01:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:BC01:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BSOIC_RD 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:BC01:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:BC01:RDHist.PROC") } record(waveform,"PLC:BSY0:BC01:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BSOIC_RD 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:BC01:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:BC01:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BSOIC_RD 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:BC01:RDReadOK.PROC") } record(longout,"PLC:BSY0:BC01:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BSOIC_RD 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:BC01:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_RD 0)READ_OK") field(FLNK,"PLC:BSY0:BC01:RDWriteOK.PROC") } record(longin,"PLC:BSY0:BC01:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_RD 0)WRITE_OK") field(FLNK,"PLC:BSY0:BC01:RDIOErrors.PROC") } record(longin,"PLC:BSY0:BC01:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_RD 0)IO_ERRORS") field(FLNK,"PLC:BSY0:BC01:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:BC01:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_RD 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:BC01:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:BC01:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_RD 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:BC01:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BSOIC_WRT 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:BC01:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:BC01:WRTHist.PROC") } record(waveform,"PLC:BSY0:BC01:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BSOIC_WRT 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:BC01:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:BC01:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BSOIC_WRT 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:BC01:WRTReadOK.PROC") } record(longout,"PLC:BSY0:BC01:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BSOIC_WRT 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:BC01:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WRT 0)READ_OK") field(FLNK,"PLC:BSY0:BC01:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:BC01:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WRT 0)WRITE_OK") field(FLNK,"PLC:BSY0:BC01:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:BC01:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WRT 0)IO_ERRORS") field(FLNK,"PLC:BSY0:BC01:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:BC01:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WRT 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:BC01:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:BC01:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WRT 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:BC01:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(BSOIC_WD 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:BC01:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:BC01:WDHist.PROC") } record(waveform,"PLC:BSY0:BC01:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BSOIC_WD 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:BC01:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:BC01:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(BSOIC_WD 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:BC01:WDReadOK.PROC") } record(longout,"PLC:BSY0:BC01:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(BSOIC_WD 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:BC01:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WD 0)READ_OK") field(FLNK,"PLC:BSY0:BC01:WDWriteOK.PROC") } record(longin,"PLC:BSY0:BC01:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WD 0)WRITE_OK") field(FLNK,"PLC:BSY0:BC01:WDIOErrors.PROC") } record(longin,"PLC:BSY0:BC01:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WD 0)IO_ERRORS") field(FLNK,"PLC:BSY0:BC01:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:BC01:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WD 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:BC01:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:BC01:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(BSOIC_WD 0)MAX_IO_TIME") } # LCLS alarming template for the BSY BSOICs factoring in bypass mode. record(calcout, "BSOC:BSY0:4:CALCALARMSUM") { field(SCAN, "2 second") field(CALC, "(!B)*A") field(INPA, "BSOC:BSY0:4:CHOK.SEVR MS") field(INPB, "BSOC:BSY0:1:MODE") field(OUT, "BSOC:BSY0:4:ALARMSUM PP") field(OOPT, "Every Time") } record(mbbi, "BSOC:BSY0:4:ALARMSUM") { field(DESC, "BSOC:BSY0:4 alarm sum") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(THVL, "3") field(ZRST, "NO_ALARM") field(ONST, "MINOR") field(TWST, "MAJOR") field(THST, "INVALID") field(ZRSV, "NO_ALARM") field(ONSV, "MINOR") field(TWSV, "MAJOR") field(THSV, "INVALID") } # LCLS alarming template for the BSY BSOICs factoring in bypass mode. record(calcout, "BSOC:BSY0:6:CALCALARMSUM") { field(SCAN, "2 second") field(CALC, "(!B)*A") field(INPA, "BSOC:BSY0:6:CHOK.SEVR MS") field(INPB, "BSOC:BSY0:1:MODE") field(OUT, "BSOC:BSY0:6:ALARMSUM PP") field(OOPT, "Every Time") } record(mbbi, "BSOC:BSY0:6:ALARMSUM") { field(DESC, "BSOC:BSY0:6 alarm sum") field(ZRVL, "0") field(ONVL, "1") field(TWVL, "2") field(THVL, "3") field(ZRST, "NO_ALARM") field(ONST, "MINOR") field(TWST, "MAJOR") field(THST, "INVALID") field(ZRSV, "NO_ALARM") field(ONSV, "MINOR") field(TWSV, "MAJOR") field(THSV, "INVALID") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi7") { field(DESC, "Port 30BSY_RDA bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 7, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:SYSE:1:HW_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:HW_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:HW_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:HW_ENABLE_A") { field(DESC, "HW Enabled A") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb7",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb7") #! Field("PLC:BSY0:PP09:30BSY_RDAb7.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb7.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb7.FLNK","PPS:SYSE:1:HW_ENABLE_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb7.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb7.VAL") #! Record("PPS:SYSE:1:HW_ENABLE_A_calc",260,18,0,1,"PPS:SYSE:1:HW_ENABLE_A_calc") #! Field("PPS:SYSE:1:HW_ENABLE_A_calc.INPA",16777215,0,"PPS:SYSE:1:HW_ENABLE_A_calc.INPA") #! Link("PPS:SYSE:1:HW_ENABLE_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb7.VAL") #! Field("PPS:SYSE:1:HW_ENABLE_A_calc.INPB",16777215,1,"PPS:SYSE:1:HW_ENABLE_A_calc.INPB") #! Field("PPS:SYSE:1:HW_ENABLE_A_calc.OUT",16777215,1,"PPS:SYSE:1:HW_ENABLE_A_calc.OUT") #! Link("PPS:SYSE:1:HW_ENABLE_A_calc.OUT","PPS:SYSE:1:HW_ENABLE_A.VAL") #! Record("PPS:SYSE:1:HW_ENABLE_A",500,20,0,0,"PPS:SYSE:1:HW_ENABLE_A") #! Field("PPS:SYSE:1:HW_ENABLE_A.VAL",16777215,1,"PPS:SYSE:1:HW_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi6") { field(DESC, "Port 30BSY_RDA bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:CROSS_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CROSS_INTLK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CROSS_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CROSS_INTLK_A") { field(DESC, "Secure Complete from Other Chain") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb6",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb6") #! Field("PLC:BSY0:PP09:30BSY_RDAb6.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb6.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb6.FLNK","PPS:SYSE:1:CROSS_INTLK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb6.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb6.VAL") #! Record("PPS:SYSE:1:CROSS_INTLK_A_calc",260,18,0,1,"PPS:SYSE:1:CROSS_INTLK_A_calc") #! Field("PPS:SYSE:1:CROSS_INTLK_A_calc.INPA",16777215,0,"PPS:SYSE:1:CROSS_INTLK_A_calc.INPA") #! Link("PPS:SYSE:1:CROSS_INTLK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb6.VAL") #! Field("PPS:SYSE:1:CROSS_INTLK_A_calc.INPB",16777215,1,"PPS:SYSE:1:CROSS_INTLK_A_calc.INPB") #! Field("PPS:SYSE:1:CROSS_INTLK_A_calc.OUT",16777215,1,"PPS:SYSE:1:CROSS_INTLK_A_calc.OUT") #! Link("PPS:SYSE:1:CROSS_INTLK_A_calc.OUT","PPS:SYSE:1:CROSS_INTLK_A.VAL") #! Record("PPS:SYSE:1:CROSS_INTLK_A",500,20,0,0,"PPS:SYSE:1:CROSS_INTLK_A") #! Field("PPS:SYSE:1:CROSS_INTLK_A.VAL",16777215,1,"PPS:SYSE:1:CROSS_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi5") { field(DESC, "Port 30BSY_RDA bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:BLM_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BLM_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BLM_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BLM_INP_A") { field(DESC, "BCS_BLM_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb5",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb5") #! Field("PLC:BSY0:PP09:30BSY_RDAb5.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb5.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb5.FLNK","PPS:SYSE:1:BLM_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb5.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb5.VAL") #! Record("PPS:SYSE:1:BLM_INP_A_calc",260,18,0,1,"PPS:SYSE:1:BLM_INP_A_calc") #! Field("PPS:SYSE:1:BLM_INP_A_calc.INPA",16777215,0,"PPS:SYSE:1:BLM_INP_A_calc.INPA") #! Link("PPS:SYSE:1:BLM_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb5.VAL") #! Field("PPS:SYSE:1:BLM_INP_A_calc.INPB",16777215,1,"PPS:SYSE:1:BLM_INP_A_calc.INPB") #! Field("PPS:SYSE:1:BLM_INP_A_calc.OUT",16777215,1,"PPS:SYSE:1:BLM_INP_A_calc.OUT") #! Link("PPS:SYSE:1:BLM_INP_A_calc.OUT","PPS:SYSE:1:BLM_INP_A.VAL") #! Record("PPS:SYSE:1:BLM_INP_A",500,20,0,0,"PPS:SYSE:1:BLM_INP_A") #! Field("PPS:SYSE:1:BLM_INP_A.VAL",16777215,1,"PPS:SYSE:1:BLM_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi3") { field(DESC, "Port 30BSY_RDA bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 3, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:LI30:1:SECURE_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SECURE_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi3 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SECURE_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SECURE_INP_A") { field(DESC, "S30_Secure_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb3",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb3") #! Field("PLC:BSY0:PP09:30BSY_RDAb3.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb3.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb3.FLNK","PPS:LI30:1:SECURE_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb3.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb3.VAL") #! Record("PPS:LI30:1:SECURE_INP_A_calc",260,18,0,1,"PPS:LI30:1:SECURE_INP_A_calc") #! Field("PPS:LI30:1:SECURE_INP_A_calc.INPA",16777215,0,"PPS:LI30:1:SECURE_INP_A_calc.INPA") #! Link("PPS:LI30:1:SECURE_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb3.VAL") #! Field("PPS:LI30:1:SECURE_INP_A_calc.INPB",16777215,1,"PPS:LI30:1:SECURE_INP_A_calc.INPB") #! Field("PPS:LI30:1:SECURE_INP_A_calc.OUT",16777215,1,"PPS:LI30:1:SECURE_INP_A_calc.OUT") #! Link("PPS:LI30:1:SECURE_INP_A_calc.OUT","PPS:LI30:1:SECURE_INP_A.VAL") #! Record("PPS:LI30:1:SECURE_INP_A",500,20,0,0,"PPS:LI30:1:SECURE_INP_A") #! Field("PPS:LI30:1:SECURE_INP_A.VAL",16777215,1,"PPS:LI30:1:SECURE_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi2") { field(DESC, "Port 30BSY_RDA bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSY0:1:SECURE_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSY0:1:SECURE_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSY0:1:SECURE_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSY0:1:SECURE_INP_A") { field(DESC, "BSY_Secure_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb2",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb2") #! Field("PLC:BSY0:PP09:30BSY_RDAb2.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb2.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb2.FLNK","PPS:BSY0:1:SECURE_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb2.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb2.VAL") #! Record("PPS:BSY0:1:SECURE_INP_A_calc",260,18,0,1,"PPS:BSY0:1:SECURE_INP_A_calc") #! Field("PPS:BSY0:1:SECURE_INP_A_calc.INPA",16777215,0,"PPS:BSY0:1:SECURE_INP_A_calc.INPA") #! Link("PPS:BSY0:1:SECURE_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb2.VAL") #! Field("PPS:BSY0:1:SECURE_INP_A_calc.INPB",16777215,1,"PPS:BSY0:1:SECURE_INP_A_calc.INPB") #! Field("PPS:BSY0:1:SECURE_INP_A_calc.OUT",16777215,1,"PPS:BSY0:1:SECURE_INP_A_calc.OUT") #! Link("PPS:BSY0:1:SECURE_INP_A_calc.OUT","PPS:BSY0:1:SECURE_INP_A.VAL") #! Record("PPS:BSY0:1:SECURE_INP_A",500,20,0,0,"PPS:BSY0:1:SECURE_INP_A") #! Field("PPS:BSY0:1:SECURE_INP_A.VAL",16777215,1,"PPS:BSY0:1:SECURE_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi1") { field(DESC, "Port 30BSY_RDA bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:ESA0:1:RADREADY_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:ESA0:1:RADREADY_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:ESA0:1:RADREADY_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:ESA0:1:RADREADY_INP_A") { field(DESC, "ESA_Rad_Ready_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb1",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb1") #! Field("PLC:BSY0:PP09:30BSY_RDAb1.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb1.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb1.FLNK","PPS:ESA0:1:RADREADY_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb1.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb1.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_A_calc",260,18,0,1,"PPS:ESA0:1:RADREADY_INP_A_calc") #! Field("PPS:ESA0:1:RADREADY_INP_A_calc.INPA",16777215,0,"PPS:ESA0:1:RADREADY_INP_A_calc.INPA") #! Link("PPS:ESA0:1:RADREADY_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb1.VAL") #! Field("PPS:ESA0:1:RADREADY_INP_A_calc.INPB",16777215,1,"PPS:ESA0:1:RADREADY_INP_A_calc.INPB") #! Field("PPS:ESA0:1:RADREADY_INP_A_calc.OUT",16777215,1,"PPS:ESA0:1:RADREADY_INP_A_calc.OUT") #! Link("PPS:ESA0:1:RADREADY_INP_A_calc.OUT","PPS:ESA0:1:RADREADY_INP_A.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_A",500,20,0,0,"PPS:ESA0:1:RADREADY_INP_A") #! Field("PPS:ESA0:1:RADREADY_INP_A.VAL",16777215,1,"PPS:ESA0:1:RADREADY_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi0") { field(DESC, "Port 30BSY_RDA bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 0, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SUM_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SUM_OK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SUM_OK_A PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SUM_OK_A") { field(DESC, "BTM_Sum_OK_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb0",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb0") #! Field("PLC:BSY0:PP09:30BSY_RDAb0.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb0.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb0.FLNK","BTM:BSY0:1:SUM_OK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb0.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb0.VAL") #! Record("BTM:BSY0:1:SUM_OK_A_calc",260,18,0,1,"BTM:BSY0:1:SUM_OK_A_calc") #! Field("BTM:BSY0:1:SUM_OK_A_calc.INPA",16777215,0,"BTM:BSY0:1:SUM_OK_A_calc.INPA") #! Link("BTM:BSY0:1:SUM_OK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb0.VAL") #! Field("BTM:BSY0:1:SUM_OK_A_calc.INPB",16777215,1,"BTM:BSY0:1:SUM_OK_A_calc.INPB") #! Field("BTM:BSY0:1:SUM_OK_A_calc.OUT",16777215,1,"BTM:BSY0:1:SUM_OK_A_calc.OUT") #! Link("BTM:BSY0:1:SUM_OK_A_calc.OUT","BTM:BSY0:1:SUM_OK_A.VAL") #! Record("BTM:BSY0:1:SUM_OK_A",500,20,0,0,"BTM:BSY0:1:SUM_OK_A") #! Field("BTM:BSY0:1:SUM_OK_A.VAL",16777215,1,"BTM:BSY0:1:SUM_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi15") { field(DESC, "Port 30BSY_RDA bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:SYSE:1:GROUPC_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:SYSE:1:GROUPC_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:SYSE:1:GROUPC_A PP MS") field(ASG, "Internal") } record(bi, "BSOC:SYSE:1:GROUPC_A") { field(DESC, "BSOIC_GrpC_OK_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb15",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb15") #! Field("PLC:BSY0:PP09:30BSY_RDAb15.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb15.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb15.FLNK","BSOC:SYSE:1:GROUPC_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb15.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb15.VAL") #! Record("BSOC:SYSE:1:GROUPC_A_calc",260,18,0,1,"BSOC:SYSE:1:GROUPC_A_calc") #! Field("BSOC:SYSE:1:GROUPC_A_calc.INPA",16777215,0,"BSOC:SYSE:1:GROUPC_A_calc.INPA") #! Link("BSOC:SYSE:1:GROUPC_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb15.VAL") #! Field("BSOC:SYSE:1:GROUPC_A_calc.INPB",16777215,1,"BSOC:SYSE:1:GROUPC_A_calc.INPB") #! Field("BSOC:SYSE:1:GROUPC_A_calc.OUT",16777215,1,"BSOC:SYSE:1:GROUPC_A_calc.OUT") #! Link("BSOC:SYSE:1:GROUPC_A_calc.OUT","BSOC:SYSE:1:GROUPC_A.VAL") #! Record("BSOC:SYSE:1:GROUPC_A",500,20,0,0,"BSOC:SYSE:1:GROUPC_A") #! Field("BSOC:SYSE:1:GROUPC_A.VAL",16777215,1,"BSOC:SYSE:1:GROUPC_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi14") { field(DESC, "Port 30BSY_RDA bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:UND0:1:SECURE_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:UND0:1:SECURE_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:UND0:1:SECURE_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:UND0:1:SECURE_INP_A") { field(DESC, "LCLS_Secure_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb14",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb14") #! Field("PLC:BSY0:PP09:30BSY_RDAb14.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb14.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb14.FLNK","PPS:UND0:1:SECURE_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb14.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb14.VAL") #! Record("PPS:UND0:1:SECURE_INP_A_calc",260,18,0,1,"PPS:UND0:1:SECURE_INP_A_calc") #! Field("PPS:UND0:1:SECURE_INP_A_calc.INPA",16777215,0,"PPS:UND0:1:SECURE_INP_A_calc.INPA") #! Link("PPS:UND0:1:SECURE_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb14.VAL") #! Field("PPS:UND0:1:SECURE_INP_A_calc.INPB",16777215,1,"PPS:UND0:1:SECURE_INP_A_calc.INPB") #! Field("PPS:UND0:1:SECURE_INP_A_calc.OUT",16777215,1,"PPS:UND0:1:SECURE_INP_A_calc.OUT") #! Link("PPS:UND0:1:SECURE_INP_A_calc.OUT","PPS:UND0:1:SECURE_INP_A.VAL") #! Record("PPS:UND0:1:SECURE_INP_A",500,20,0,0,"PPS:UND0:1:SECURE_INP_A") #! Field("PPS:UND0:1:SECURE_INP_A.VAL",16777215,1,"PPS:UND0:1:SECURE_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi13") { field(DESC, "Port 30BSY_RDA bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 13, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_A") { field(DESC, "Local_Beam_Enable_Keysw_A") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb13",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb13") #! Field("PLC:BSY0:PP09:30BSY_RDAb13.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb13.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb13.FLNK","PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb13.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb13.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb13.VAL") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A_calc.OUT","PPS:SYSE:1:30BSY:LOCAL_ENABLE_A.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A",500,20,0,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_A") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi12") { field(DESC, "Port 30BSY_RDA bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 12, 1, 1)") field(ZNAM, "Not_Lowered") field(ONAM, "Lowered") field(FLNK, "PPS:LTU0:1:BCS_TRP_LOW_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LTU0:1:BCS_TRP_LOW_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LTU0:1:BCS_TRP_LOW_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LTU0:1:BCS_TRP_LOW_A") { field(DESC, "BCS_BTH_Trips_Low_Inp_A") field(ZNAM, "Not_Lowered") field(ONAM, "Lowered") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb12",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb12") #! Field("PLC:BSY0:PP09:30BSY_RDAb12.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb12.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb12.FLNK","PPS:LTU0:1:BCS_TRP_LOW_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb12.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb12.VAL") #! Record("PPS:LTU0:1:BCS_TRP_LOW_A_calc",260,18,0,1,"PPS:LTU0:1:BCS_TRP_LOW_A_calc") #! Field("PPS:LTU0:1:BCS_TRP_LOW_A_calc.INPA",16777215,0,"PPS:LTU0:1:BCS_TRP_LOW_A_calc.INPA") #! Link("PPS:LTU0:1:BCS_TRP_LOW_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb12.VAL") #! Field("PPS:LTU0:1:BCS_TRP_LOW_A_calc.INPB",16777215,1,"PPS:LTU0:1:BCS_TRP_LOW_A_calc.INPB") #! Field("PPS:LTU0:1:BCS_TRP_LOW_A_calc.OUT",16777215,1,"PPS:LTU0:1:BCS_TRP_LOW_A_calc.OUT") #! Link("PPS:LTU0:1:BCS_TRP_LOW_A_calc.OUT","PPS:LTU0:1:BCS_TRP_LOW_A.VAL") #! Record("PPS:LTU0:1:BCS_TRP_LOW_A",500,20,0,0,"PPS:LTU0:1:BCS_TRP_LOW_A") #! Field("PPS:LTU0:1:BCS_TRP_LOW_A.VAL",16777215,1,"PPS:LTU0:1:BCS_TRP_LOW_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi10") { field(DESC, "Port 30BSY_RDA bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 10, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:ACR_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:ACR_ENABLE_A") { field(DESC, "ACR_Beam_Enable_Keysw_A") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb10",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb10") #! Field("PLC:BSY0:PP09:30BSY_RDAb10.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb10.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb10.FLNK","PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb10.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb10.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb10.VAL") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_A_calc.OUT","PPS:SYSE:1:30BSY:ACR_ENABLE_A.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_A",500,20,0,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_A") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi9") { field(DESC, "Port 30BSY_RDA bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 9, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI28:1:HXR:KICKSEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICKSEP_OFF_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICKSEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICKSEP_OFF_A") { field(DESC, "HXR_KickSept_Off_Inp_A") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb9",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb9") #! Field("PLC:BSY0:PP09:30BSY_RDAb9.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb9.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb9.FLNK","PPS:LI28:1:HXR:KICKSEP_OFF_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb9.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb9.VAL") #! Record("PPS:LI28:1:HXR:KICKSEP_OFF_A_calc",260,18,0,1,"PPS:LI28:1:HXR:KICKSEP_OFF_A_calc") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.INPA") #! Link("PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb9.VAL") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.INPB") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.OUT") #! Link("PPS:LI28:1:HXR:KICKSEP_OFF_A_calc.OUT","PPS:LI28:1:HXR:KICKSEP_OFF_A.VAL") #! Record("PPS:LI28:1:HXR:KICKSEP_OFF_A",500,20,0,0,"PPS:LI28:1:HXR:KICKSEP_OFF_A") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_A.VAL",16777215,1,"PPS:LI28:1:HXR:KICKSEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi8") { field(DESC, "Port 30BSY_RDA bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 8, 1, 1)") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(FLNK, "PPS:LI28:1:HXR:KICK_COND_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICK_COND_OK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICK_COND_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICK_COND_OK_A") { field(DESC, "HXR_Kick_OK_A") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb8",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb8") #! Field("PLC:BSY0:PP09:30BSY_RDAb8.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb8.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb8.FLNK","PPS:LI28:1:HXR:KICK_COND_OK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb8.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb8.VAL") #! Record("PPS:LI28:1:HXR:KICK_COND_OK_A_calc",260,18,0,1,"PPS:LI28:1:HXR:KICK_COND_OK_A_calc") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_A_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICK_COND_OK_A_calc.INPA") #! Link("PPS:LI28:1:HXR:KICK_COND_OK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb8.VAL") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_A_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICK_COND_OK_A_calc.INPB") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_A_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICK_COND_OK_A_calc.OUT") #! Link("PPS:LI28:1:HXR:KICK_COND_OK_A_calc.OUT","PPS:LI28:1:HXR:KICK_COND_OK_A.VAL") #! Record("PPS:LI28:1:HXR:KICK_COND_OK_A",500,20,0,0,"PPS:LI28:1:HXR:KICK_COND_OK_A") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_A.VAL",16777215,1,"PPS:LI28:1:HXR:KICK_COND_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi23") { field(DESC, "Port 30BSY_RDA bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 23, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI30:1:SXR:KICKSEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SXR:KICKSEP_OFF_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SXR:KICKSEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SXR:KICKSEP_OFF_A") { field(DESC, "SXR_KickSept_Off_Inp_A") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb23",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb23") #! Field("PLC:BSY0:PP09:30BSY_RDAb23.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb23.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb23.FLNK","PPS:LI30:1:SXR:KICKSEP_OFF_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb23.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb23.VAL") #! Record("PPS:LI30:1:SXR:KICKSEP_OFF_A_calc",260,18,0,1,"PPS:LI30:1:SXR:KICKSEP_OFF_A_calc") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.INPA",16777215,0,"PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.INPA") #! Link("PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb23.VAL") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.INPB",16777215,1,"PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.INPB") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.OUT",16777215,1,"PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.OUT") #! Link("PPS:LI30:1:SXR:KICKSEP_OFF_A_calc.OUT","PPS:LI30:1:SXR:KICKSEP_OFF_A.VAL") #! Record("PPS:LI30:1:SXR:KICKSEP_OFF_A",500,20,0,0,"PPS:LI30:1:SXR:KICKSEP_OFF_A") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_A.VAL",16777215,1,"PPS:LI30:1:SXR:KICKSEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi22") { field(DESC, "Port 30BSY_RDA bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 22, 1, 1)") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(FLNK, "PPS:LI30:1:SXR:KICK_COND_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SXR:KICK_COND_OK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SXR:KICK_COND_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SXR:KICK_COND_OK_A") { field(DESC, "SXR_Kick_OK_A") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb22",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb22") #! Field("PLC:BSY0:PP09:30BSY_RDAb22.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb22.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb22.FLNK","PPS:LI30:1:SXR:KICK_COND_OK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb22.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb22.VAL") #! Record("PPS:LI30:1:SXR:KICK_COND_OK_A_calc",260,18,0,1,"PPS:LI30:1:SXR:KICK_COND_OK_A_calc") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_A_calc.INPA",16777215,0,"PPS:LI30:1:SXR:KICK_COND_OK_A_calc.INPA") #! Link("PPS:LI30:1:SXR:KICK_COND_OK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb22.VAL") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_A_calc.INPB",16777215,1,"PPS:LI30:1:SXR:KICK_COND_OK_A_calc.INPB") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_A_calc.OUT",16777215,1,"PPS:LI30:1:SXR:KICK_COND_OK_A_calc.OUT") #! Link("PPS:LI30:1:SXR:KICK_COND_OK_A_calc.OUT","PPS:LI30:1:SXR:KICK_COND_OK_A.VAL") #! Record("PPS:LI30:1:SXR:KICK_COND_OK_A",500,20,0,0,"PPS:LI30:1:SXR:KICK_COND_OK_A") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_A.VAL",16777215,1,"PPS:LI30:1:SXR:KICK_COND_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi21") { field(DESC, "Port 30BSY_RDA bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 21, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:1:30BSY:STD2_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:30BSY:STD2_IN_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:30BSY:STD2_IN_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:30BSY:STD2_IN_A") { field(DESC, "STD2_Set_In_30BSY_Inp_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb21",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb21") #! Field("PLC:BSY0:PP09:30BSY_RDAb21.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb21.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb21.FLNK","STPR:BSYH:1:30BSY:STD2_IN_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb21.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb21.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_IN_A_calc",260,18,0,1,"STPR:BSYH:1:30BSY:STD2_IN_A_calc") #! Field("STPR:BSYH:1:30BSY:STD2_IN_A_calc.INPA",16777215,0,"STPR:BSYH:1:30BSY:STD2_IN_A_calc.INPA") #! Link("STPR:BSYH:1:30BSY:STD2_IN_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb21.VAL") #! Field("STPR:BSYH:1:30BSY:STD2_IN_A_calc.INPB",16777215,1,"STPR:BSYH:1:30BSY:STD2_IN_A_calc.INPB") #! Field("STPR:BSYH:1:30BSY:STD2_IN_A_calc.OUT",16777215,1,"STPR:BSYH:1:30BSY:STD2_IN_A_calc.OUT") #! Link("STPR:BSYH:1:30BSY:STD2_IN_A_calc.OUT","STPR:BSYH:1:30BSY:STD2_IN_A.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_IN_A",500,20,0,0,"STPR:BSYH:1:30BSY:STD2_IN_A") #! Field("STPR:BSYH:1:30BSY:STD2_IN_A.VAL",16777215,1,"STPR:BSYH:1:30BSY:STD2_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi20") { field(DESC, "Port 30BSY_RDA bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 20, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:1:30BSY:STD2_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:30BSY:STD2_OUT_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:30BSY:STD2_OUT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:30BSY:STD2_OUT_A") { field(DESC, "STD2_Set_Out_30BSY_Inp_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb20",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb20") #! Field("PLC:BSY0:PP09:30BSY_RDAb20.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb20.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb20.FLNK","STPR:BSYH:1:30BSY:STD2_OUT_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb20.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb20.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_OUT_A_calc",260,18,0,1,"STPR:BSYH:1:30BSY:STD2_OUT_A_calc") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_A_calc.INPA",16777215,0,"STPR:BSYH:1:30BSY:STD2_OUT_A_calc.INPA") #! Link("STPR:BSYH:1:30BSY:STD2_OUT_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb20.VAL") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_A_calc.INPB",16777215,1,"STPR:BSYH:1:30BSY:STD2_OUT_A_calc.INPB") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_A_calc.OUT",16777215,1,"STPR:BSYH:1:30BSY:STD2_OUT_A_calc.OUT") #! Link("STPR:BSYH:1:30BSY:STD2_OUT_A_calc.OUT","STPR:BSYH:1:30BSY:STD2_OUT_A.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_OUT_A",500,20,0,0,"STPR:BSYH:1:30BSY:STD2_OUT_A") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_A.VAL",16777215,1,"STPR:BSYH:1:30BSY:STD2_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi19") { field(DESC, "Port 30BSY_RDA bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 19, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYS:1:ST34_IN_SUM_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:1:ST34_IN_SUM_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi19 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:1:ST34_IN_SUM_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:1:ST34_IN_SUM_A") { field(DESC, "ST34_Set_In_Inp_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb19",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb19") #! Field("PLC:BSY0:PP09:30BSY_RDAb19.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb19.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb19.FLNK","STPR:BSYS:1:ST34_IN_SUM_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb19.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb19.VAL") #! Record("STPR:BSYS:1:ST34_IN_SUM_A_calc",260,18,0,1,"STPR:BSYS:1:ST34_IN_SUM_A_calc") #! Field("STPR:BSYS:1:ST34_IN_SUM_A_calc.INPA",16777215,0,"STPR:BSYS:1:ST34_IN_SUM_A_calc.INPA") #! Link("STPR:BSYS:1:ST34_IN_SUM_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb19.VAL") #! Field("STPR:BSYS:1:ST34_IN_SUM_A_calc.INPB",16777215,1,"STPR:BSYS:1:ST34_IN_SUM_A_calc.INPB") #! Field("STPR:BSYS:1:ST34_IN_SUM_A_calc.OUT",16777215,1,"STPR:BSYS:1:ST34_IN_SUM_A_calc.OUT") #! Link("STPR:BSYS:1:ST34_IN_SUM_A_calc.OUT","STPR:BSYS:1:ST34_IN_SUM_A.VAL") #! Record("STPR:BSYS:1:ST34_IN_SUM_A",500,20,0,0,"STPR:BSYS:1:ST34_IN_SUM_A") #! Field("STPR:BSYS:1:ST34_IN_SUM_A.VAL",16777215,1,"STPR:BSYS:1:ST34_IN_SUM_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi18") { field(DESC, "Port 30BSY_RDA bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 18, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYS:1:ST34_OUT_SUM_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:1:ST34_OUT_SUM_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi18 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:1:ST34_OUT_SUM_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:1:ST34_OUT_SUM_A") { field(DESC, "ST34_Set_Out_Inp_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb18",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb18") #! Field("PLC:BSY0:PP09:30BSY_RDAb18.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb18.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb18.FLNK","STPR:BSYS:1:ST34_OUT_SUM_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb18.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb18.VAL") #! Record("STPR:BSYS:1:ST34_OUT_SUM_A_calc",260,18,0,1,"STPR:BSYS:1:ST34_OUT_SUM_A_calc") #! Field("STPR:BSYS:1:ST34_OUT_SUM_A_calc.INPA",16777215,0,"STPR:BSYS:1:ST34_OUT_SUM_A_calc.INPA") #! Link("STPR:BSYS:1:ST34_OUT_SUM_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb18.VAL") #! Field("STPR:BSYS:1:ST34_OUT_SUM_A_calc.INPB",16777215,1,"STPR:BSYS:1:ST34_OUT_SUM_A_calc.INPB") #! Field("STPR:BSYS:1:ST34_OUT_SUM_A_calc.OUT",16777215,1,"STPR:BSYS:1:ST34_OUT_SUM_A_calc.OUT") #! Link("STPR:BSYS:1:ST34_OUT_SUM_A_calc.OUT","STPR:BSYS:1:ST34_OUT_SUM_A.VAL") #! Record("STPR:BSYS:1:ST34_OUT_SUM_A",500,20,0,0,"STPR:BSYS:1:ST34_OUT_SUM_A") #! Field("STPR:BSYS:1:ST34_OUT_SUM_A.VAL",16777215,1,"STPR:BSYS:1:ST34_OUT_SUM_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi17") { field(DESC, "Port 30BSY_RDA bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 17, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:CLTS:585:IN_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:IN_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi17 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:IN_INP_A PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:IN_INP_A") { field(DESC, "STCLTS_In_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb17",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb17") #! Field("PLC:BSY0:PP09:30BSY_RDAb17.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb17.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb17.FLNK","STPR:CLTS:585:IN_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb17.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb17.VAL") #! Record("STPR:CLTS:585:IN_INP_A_calc",260,18,0,1,"STPR:CLTS:585:IN_INP_A_calc") #! Field("STPR:CLTS:585:IN_INP_A_calc.INPA",16777215,0,"STPR:CLTS:585:IN_INP_A_calc.INPA") #! Link("STPR:CLTS:585:IN_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb17.VAL") #! Field("STPR:CLTS:585:IN_INP_A_calc.INPB",16777215,1,"STPR:CLTS:585:IN_INP_A_calc.INPB") #! Field("STPR:CLTS:585:IN_INP_A_calc.OUT",16777215,1,"STPR:CLTS:585:IN_INP_A_calc.OUT") #! Link("STPR:CLTS:585:IN_INP_A_calc.OUT","STPR:CLTS:585:IN_INP_A.VAL") #! Record("STPR:CLTS:585:IN_INP_A",500,20,0,0,"STPR:CLTS:585:IN_INP_A") #! Field("STPR:CLTS:585:IN_INP_A.VAL",16777215,1,"STPR:CLTS:585:IN_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi16") { field(DESC, "Port 30BSY_RDA bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 16, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:CLTS:585:OUT_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:OUT_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi16 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:OUT_INP_A PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:OUT_INP_A") { field(DESC, "STCLTS_Out_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb16",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb16") #! Field("PLC:BSY0:PP09:30BSY_RDAb16.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb16.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb16.FLNK","STPR:CLTS:585:OUT_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb16.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb16.VAL") #! Record("STPR:CLTS:585:OUT_INP_A_calc",260,18,0,1,"STPR:CLTS:585:OUT_INP_A_calc") #! Field("STPR:CLTS:585:OUT_INP_A_calc.INPA",16777215,0,"STPR:CLTS:585:OUT_INP_A_calc.INPA") #! Link("STPR:CLTS:585:OUT_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb16.VAL") #! Field("STPR:CLTS:585:OUT_INP_A_calc.INPB",16777215,1,"STPR:CLTS:585:OUT_INP_A_calc.INPB") #! Field("STPR:CLTS:585:OUT_INP_A_calc.OUT",16777215,1,"STPR:CLTS:585:OUT_INP_A_calc.OUT") #! Link("STPR:CLTS:585:OUT_INP_A_calc.OUT","STPR:CLTS:585:OUT_INP_A.VAL") #! Record("STPR:CLTS:585:OUT_INP_A",500,20,0,0,"STPR:CLTS:585:OUT_INP_A") #! Field("STPR:CLTS:585:OUT_INP_A.VAL",16777215,1,"STPR:CLTS:585:OUT_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi95") { field(DESC, "Port 30BSY_RDA bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 95, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:1:KICK_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:KICK_OFF_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi95 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:KICK_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:KICK_OFF_A") { field(DESC, "CLTS_Kicker_OFF_A") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb95",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb95") #! Field("PLC:BSY0:PP09:30BSY_RDAb95.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb95.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb95.FLNK","PPS:CLTS:1:KICK_OFF_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb95.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb95.VAL") #! Record("PPS:CLTS:1:KICK_OFF_A_calc",260,18,0,1,"PPS:CLTS:1:KICK_OFF_A_calc") #! Field("PPS:CLTS:1:KICK_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:1:KICK_OFF_A_calc.INPA") #! Link("PPS:CLTS:1:KICK_OFF_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb95.VAL") #! Field("PPS:CLTS:1:KICK_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:1:KICK_OFF_A_calc.INPB") #! Field("PPS:CLTS:1:KICK_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:1:KICK_OFF_A_calc.OUT") #! Link("PPS:CLTS:1:KICK_OFF_A_calc.OUT","PPS:CLTS:1:KICK_OFF_A.VAL") #! Record("PPS:CLTS:1:KICK_OFF_A",500,20,0,0,"PPS:CLTS:1:KICK_OFF_A") #! Field("PPS:CLTS:1:KICK_OFF_A.VAL",16777215,1,"PPS:CLTS:1:KICK_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi94") { field(DESC, "Port 30BSY_RDA bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 94, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:1:DCBEND_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:DCBEND_OFF_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi94 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:DCBEND_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:DCBEND_OFF_A") { field(DESC, "CLTS_DC_Bend_OFF_A") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb94",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb94") #! Field("PLC:BSY0:PP09:30BSY_RDAb94.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb94.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb94.FLNK","PPS:CLTS:1:DCBEND_OFF_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb94.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb94.VAL") #! Record("PPS:CLTS:1:DCBEND_OFF_A_calc",260,18,0,1,"PPS:CLTS:1:DCBEND_OFF_A_calc") #! Field("PPS:CLTS:1:DCBEND_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:1:DCBEND_OFF_A_calc.INPA") #! Link("PPS:CLTS:1:DCBEND_OFF_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb94.VAL") #! Field("PPS:CLTS:1:DCBEND_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:1:DCBEND_OFF_A_calc.INPB") #! Field("PPS:CLTS:1:DCBEND_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:1:DCBEND_OFF_A_calc.OUT") #! Link("PPS:CLTS:1:DCBEND_OFF_A_calc.OUT","PPS:CLTS:1:DCBEND_OFF_A.VAL") #! Record("PPS:CLTS:1:DCBEND_OFF_A",500,20,0,0,"PPS:CLTS:1:DCBEND_OFF_A") #! Field("PPS:CLTS:1:DCBEND_OFF_A.VAL",16777215,1,"PPS:CLTS:1:DCBEND_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi92") { field(DESC, "Port 30BSY_RDA bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 92, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:BSYS:1:MERGE_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:MERGE_OFF_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi92 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:MERGE_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:MERGE_OFF_A") { field(DESC, "SXR_Merge_Dipole_OFF_A") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb92",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb92") #! Field("PLC:BSY0:PP09:30BSY_RDAb92.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb92.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb92.FLNK","PPS:BSYS:1:MERGE_OFF_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb92.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb92.VAL") #! Record("PPS:BSYS:1:MERGE_OFF_A_calc",260,18,0,1,"PPS:BSYS:1:MERGE_OFF_A_calc") #! Field("PPS:BSYS:1:MERGE_OFF_A_calc.INPA",16777215,0,"PPS:BSYS:1:MERGE_OFF_A_calc.INPA") #! Link("PPS:BSYS:1:MERGE_OFF_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb92.VAL") #! Field("PPS:BSYS:1:MERGE_OFF_A_calc.INPB",16777215,1,"PPS:BSYS:1:MERGE_OFF_A_calc.INPB") #! Field("PPS:BSYS:1:MERGE_OFF_A_calc.OUT",16777215,1,"PPS:BSYS:1:MERGE_OFF_A_calc.OUT") #! Link("PPS:BSYS:1:MERGE_OFF_A_calc.OUT","PPS:BSYS:1:MERGE_OFF_A.VAL") #! Record("PPS:BSYS:1:MERGE_OFF_A",500,20,0,0,"PPS:BSYS:1:MERGE_OFF_A") #! Field("PPS:BSYS:1:MERGE_OFF_A.VAL",16777215,1,"PPS:BSYS:1:MERGE_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi90") { field(DESC, "Port 30BSY_RDA bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 90, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:CLTS:1:DCBEND_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:DCBEND_ON_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:DCBEND_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:DCBEND_ON_A") { field(DESC, "CLTS_DC_Bend_On_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb90",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb90") #! Field("PLC:BSY0:PP09:30BSY_RDAb90.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb90.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb90.FLNK","PPS:CLTS:1:DCBEND_ON_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb90.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb90.VAL") #! Record("PPS:CLTS:1:DCBEND_ON_A_calc",260,18,0,1,"PPS:CLTS:1:DCBEND_ON_A_calc") #! Field("PPS:CLTS:1:DCBEND_ON_A_calc.INPA",16777215,0,"PPS:CLTS:1:DCBEND_ON_A_calc.INPA") #! Link("PPS:CLTS:1:DCBEND_ON_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb90.VAL") #! Field("PPS:CLTS:1:DCBEND_ON_A_calc.INPB",16777215,1,"PPS:CLTS:1:DCBEND_ON_A_calc.INPB") #! Field("PPS:CLTS:1:DCBEND_ON_A_calc.OUT",16777215,1,"PPS:CLTS:1:DCBEND_ON_A_calc.OUT") #! Link("PPS:CLTS:1:DCBEND_ON_A_calc.OUT","PPS:CLTS:1:DCBEND_ON_A.VAL") #! Record("PPS:CLTS:1:DCBEND_ON_A",500,20,0,0,"PPS:CLTS:1:DCBEND_ON_A") #! Field("PPS:CLTS:1:DCBEND_ON_A.VAL",16777215,1,"PPS:CLTS:1:DCBEND_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi89") { field(DESC, "Port 30BSY_RDA bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 89, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:CLTS:1:SEP_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:SEP_ON_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:SEP_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:SEP_ON_A") { field(DESC, "CLTS_Septum_On_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb89",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb89") #! Field("PLC:BSY0:PP09:30BSY_RDAb89.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb89.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb89.FLNK","PPS:CLTS:1:SEP_ON_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb89.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb89.VAL") #! Record("PPS:CLTS:1:SEP_ON_A_calc",260,18,0,1,"PPS:CLTS:1:SEP_ON_A_calc") #! Field("PPS:CLTS:1:SEP_ON_A_calc.INPA",16777215,0,"PPS:CLTS:1:SEP_ON_A_calc.INPA") #! Link("PPS:CLTS:1:SEP_ON_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb89.VAL") #! Field("PPS:CLTS:1:SEP_ON_A_calc.INPB",16777215,1,"PPS:CLTS:1:SEP_ON_A_calc.INPB") #! Field("PPS:CLTS:1:SEP_ON_A_calc.OUT",16777215,1,"PPS:CLTS:1:SEP_ON_A_calc.OUT") #! Link("PPS:CLTS:1:SEP_ON_A_calc.OUT","PPS:CLTS:1:SEP_ON_A.VAL") #! Record("PPS:CLTS:1:SEP_ON_A",500,20,0,0,"PPS:CLTS:1:SEP_ON_A") #! Field("PPS:CLTS:1:SEP_ON_A.VAL",16777215,1,"PPS:CLTS:1:SEP_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi88") { field(DESC, "Port 30BSY_RDA bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 88, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:MERGE_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:MERGE_ON_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:MERGE_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:MERGE_ON_A") { field(DESC, "SXR_Merge_Dipole_On_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb88",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb88") #! Field("PLC:BSY0:PP09:30BSY_RDAb88.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb88.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb88.FLNK","PPS:BSYS:1:MERGE_ON_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb88.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb88.VAL") #! Record("PPS:BSYS:1:MERGE_ON_A_calc",260,18,0,1,"PPS:BSYS:1:MERGE_ON_A_calc") #! Field("PPS:BSYS:1:MERGE_ON_A_calc.INPA",16777215,0,"PPS:BSYS:1:MERGE_ON_A_calc.INPA") #! Link("PPS:BSYS:1:MERGE_ON_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb88.VAL") #! Field("PPS:BSYS:1:MERGE_ON_A_calc.INPB",16777215,1,"PPS:BSYS:1:MERGE_ON_A_calc.INPB") #! Field("PPS:BSYS:1:MERGE_ON_A_calc.OUT",16777215,1,"PPS:BSYS:1:MERGE_ON_A_calc.OUT") #! Link("PPS:BSYS:1:MERGE_ON_A_calc.OUT","PPS:BSYS:1:MERGE_ON_A.VAL") #! Record("PPS:BSYS:1:MERGE_ON_A",500,20,0,0,"PPS:BSYS:1:MERGE_ON_A") #! Field("PPS:BSYS:1:MERGE_ON_A.VAL",16777215,1,"PPS:BSYS:1:MERGE_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi103") { field(DESC, "Port 30BSY_RDA bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 103, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:30BSY:INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:INTLK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:INTLK_A") { field(DESC, "30-BSY interlock A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb103",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb103") #! Field("PLC:BSY0:PP09:30BSY_RDAb103.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb103.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb103.FLNK","PPS:SYSE:1:30BSY:INTLK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb103.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb103.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:INTLK_A_calc") #! Field("PPS:SYSE:1:30BSY:INTLK_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:INTLK_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:INTLK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb103.VAL") #! Field("PPS:SYSE:1:30BSY:INTLK_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:INTLK_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:INTLK_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:INTLK_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:INTLK_A_calc.OUT","PPS:SYSE:1:30BSY:INTLK_A.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_A",500,20,0,0,"PPS:SYSE:1:30BSY:INTLK_A") #! Field("PPS:SYSE:1:30BSY:INTLK_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi102") { field(DESC, "Port 30BSY_RDA bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 102, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:CU:INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:INTLK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:INTLK_A") { field(DESC, "Cu beam interlock A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb102",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb102") #! Field("PLC:BSY0:PP09:30BSY_RDAb102.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb102.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb102.FLNK","PPS:SYSE:1:CU:INTLK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb102.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb102.VAL") #! Record("PPS:SYSE:1:CU:INTLK_A_calc",260,18,0,1,"PPS:SYSE:1:CU:INTLK_A_calc") #! Field("PPS:SYSE:1:CU:INTLK_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:INTLK_A_calc.INPA") #! Link("PPS:SYSE:1:CU:INTLK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb102.VAL") #! Field("PPS:SYSE:1:CU:INTLK_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:INTLK_A_calc.INPB") #! Field("PPS:SYSE:1:CU:INTLK_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:INTLK_A_calc.OUT") #! Link("PPS:SYSE:1:CU:INTLK_A_calc.OUT","PPS:SYSE:1:CU:INTLK_A.VAL") #! Record("PPS:SYSE:1:CU:INTLK_A",500,20,0,0,"PPS:SYSE:1:CU:INTLK_A") #! Field("PPS:SYSE:1:CU:INTLK_A.VAL",16777215,1,"PPS:SYSE:1:CU:INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi101") { field(DESC, "Port 30BSY_RDA bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 101, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:SC:INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SC:INTLK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SC:INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SC:INTLK_A") { field(DESC, "SC beam interlock A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb101",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb101") #! Field("PLC:BSY0:PP09:30BSY_RDAb101.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb101.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb101.FLNK","PPS:SYSE:1:SC:INTLK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb101.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb101.VAL") #! Record("PPS:SYSE:1:SC:INTLK_A_calc",260,18,0,1,"PPS:SYSE:1:SC:INTLK_A_calc") #! Field("PPS:SYSE:1:SC:INTLK_A_calc.INPA",16777215,0,"PPS:SYSE:1:SC:INTLK_A_calc.INPA") #! Link("PPS:SYSE:1:SC:INTLK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb101.VAL") #! Field("PPS:SYSE:1:SC:INTLK_A_calc.INPB",16777215,1,"PPS:SYSE:1:SC:INTLK_A_calc.INPB") #! Field("PPS:SYSE:1:SC:INTLK_A_calc.OUT",16777215,1,"PPS:SYSE:1:SC:INTLK_A_calc.OUT") #! Link("PPS:SYSE:1:SC:INTLK_A_calc.OUT","PPS:SYSE:1:SC:INTLK_A.VAL") #! Record("PPS:SYSE:1:SC:INTLK_A",500,20,0,0,"PPS:SYSE:1:SC:INTLK_A") #! Field("PPS:SYSE:1:SC:INTLK_A.VAL",16777215,1,"PPS:SYSE:1:SC:INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi100") { field(DESC, "Port 30BSY_RDA bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 100, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:BTH_ACCESS_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BTH_ACCESS_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BTH_ACCESS_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BTH_ACCESS_A") { field(DESC, "BTH Access cond. A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb100",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb100") #! Field("PLC:BSY0:PP09:30BSY_RDAb100.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb100.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb100.FLNK","PPS:SYSE:1:BTH_ACCESS_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb100.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb100.VAL") #! Record("PPS:SYSE:1:BTH_ACCESS_A_calc",260,18,0,1,"PPS:SYSE:1:BTH_ACCESS_A_calc") #! Field("PPS:SYSE:1:BTH_ACCESS_A_calc.INPA",16777215,0,"PPS:SYSE:1:BTH_ACCESS_A_calc.INPA") #! Link("PPS:SYSE:1:BTH_ACCESS_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb100.VAL") #! Field("PPS:SYSE:1:BTH_ACCESS_A_calc.INPB",16777215,1,"PPS:SYSE:1:BTH_ACCESS_A_calc.INPB") #! Field("PPS:SYSE:1:BTH_ACCESS_A_calc.OUT",16777215,1,"PPS:SYSE:1:BTH_ACCESS_A_calc.OUT") #! Link("PPS:SYSE:1:BTH_ACCESS_A_calc.OUT","PPS:SYSE:1:BTH_ACCESS_A.VAL") #! Record("PPS:SYSE:1:BTH_ACCESS_A",500,20,0,0,"PPS:SYSE:1:BTH_ACCESS_A") #! Field("PPS:SYSE:1:BTH_ACCESS_A.VAL",16777215,1,"PPS:SYSE:1:BTH_ACCESS_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi99") { field(DESC, "Port 30BSY_RDA bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 99, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi99 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:CROSS_CHECK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:CROSS_CHECK_A") { field(DESC, "Cross_Check_Keysw_in_Normal_A") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb99",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb99") #! Field("PLC:BSY0:PP09:30BSY_RDAb99.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb99.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb99.FLNK","PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb99.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb99.VAL") #! Record("PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb99.VAL") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:CROSS_CHECK_A_calc.OUT","PPS:SYSE:1:30BSY:CROSS_CHECK_A.VAL") #! Record("PPS:SYSE:1:30BSY:CROSS_CHECK_A",500,20,0,0,"PPS:SYSE:1:30BSY:CROSS_CHECK_A") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi98") { field(DESC, "Port 30BSY_RDA bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_INP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi98 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_INP_A") { field(DESC, "Heartbeat IN (other chn.) A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb98",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb98") #! Field("PLC:BSY0:PP09:30BSY_RDAb98.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb98.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb98.FLNK","PPS:SYSE:1:30BSY:HRTBT_INP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb98.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb98.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_INP_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_INP_A_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb98.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_INP_A_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_INP_A.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_INP_A",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_INP_A") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi97") { field(DESC, "Port 30BSY_RDA bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 97, 1, 1)") field(ZNAM, "NOT_READY") field(ONAM, "READY") field(FLNK, "PPS:SYSE:1:BEAM_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BEAM_ON_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BEAM_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BEAM_ON_A") { field(DESC, "Linac E. Global in Ready for Beam") field(ZNAM, "NOT_READY") field(ONAM, "READY") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb97",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb97") #! Field("PLC:BSY0:PP09:30BSY_RDAb97.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb97.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb97.FLNK","PPS:SYSE:1:BEAM_ON_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb97.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb97.VAL") #! Record("PPS:SYSE:1:BEAM_ON_A_calc",260,18,0,1,"PPS:SYSE:1:BEAM_ON_A_calc") #! Field("PPS:SYSE:1:BEAM_ON_A_calc.INPA",16777215,0,"PPS:SYSE:1:BEAM_ON_A_calc.INPA") #! Link("PPS:SYSE:1:BEAM_ON_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb97.VAL") #! Field("PPS:SYSE:1:BEAM_ON_A_calc.INPB",16777215,1,"PPS:SYSE:1:BEAM_ON_A_calc.INPB") #! Field("PPS:SYSE:1:BEAM_ON_A_calc.OUT",16777215,1,"PPS:SYSE:1:BEAM_ON_A_calc.OUT") #! Link("PPS:SYSE:1:BEAM_ON_A_calc.OUT","PPS:SYSE:1:BEAM_ON_A.VAL") #! Record("PPS:SYSE:1:BEAM_ON_A",500,20,0,0,"PPS:SYSE:1:BEAM_ON_A") #! Field("PPS:SYSE:1:BEAM_ON_A.VAL",16777215,1,"PPS:SYSE:1:BEAM_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi111") { field(DESC, "Port 30BSY_RDA bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 111, 1, 1)") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(FLNK, "PPS:SYSE:1:HW_RESET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:HW_RESET_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:HW_RESET_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:HW_RESET_A") { field(DESC, "HW Reset A") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb111",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb111") #! Field("PLC:BSY0:PP09:30BSY_RDAb111.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb111.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb111.FLNK","PPS:SYSE:1:HW_RESET_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb111.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb111.VAL") #! Record("PPS:SYSE:1:HW_RESET_A_calc",260,18,0,1,"PPS:SYSE:1:HW_RESET_A_calc") #! Field("PPS:SYSE:1:HW_RESET_A_calc.INPA",16777215,0,"PPS:SYSE:1:HW_RESET_A_calc.INPA") #! Link("PPS:SYSE:1:HW_RESET_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb111.VAL") #! Field("PPS:SYSE:1:HW_RESET_A_calc.INPB",16777215,1,"PPS:SYSE:1:HW_RESET_A_calc.INPB") #! Field("PPS:SYSE:1:HW_RESET_A_calc.OUT",16777215,1,"PPS:SYSE:1:HW_RESET_A_calc.OUT") #! Link("PPS:SYSE:1:HW_RESET_A_calc.OUT","PPS:SYSE:1:HW_RESET_A.VAL") #! Record("PPS:SYSE:1:HW_RESET_A",500,20,0,0,"PPS:SYSE:1:HW_RESET_A") #! Field("PPS:SYSE:1:HW_RESET_A.VAL",16777215,1,"PPS:SYSE:1:HW_RESET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi110") { field(DESC, "Port 30BSY_RDA bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 110, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:SYSE:1:RSY_SECURE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:RSY_SECURE_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:RSY_SECURE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:RSY_SECURE_A") { field(DESC, "RSY Secure A") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb110",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb110") #! Field("PLC:BSY0:PP09:30BSY_RDAb110.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb110.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb110.FLNK","PPS:SYSE:1:RSY_SECURE_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb110.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb110.VAL") #! Record("PPS:SYSE:1:RSY_SECURE_A_calc",260,18,0,1,"PPS:SYSE:1:RSY_SECURE_A_calc") #! Field("PPS:SYSE:1:RSY_SECURE_A_calc.INPA",16777215,0,"PPS:SYSE:1:RSY_SECURE_A_calc.INPA") #! Link("PPS:SYSE:1:RSY_SECURE_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb110.VAL") #! Field("PPS:SYSE:1:RSY_SECURE_A_calc.INPB",16777215,1,"PPS:SYSE:1:RSY_SECURE_A_calc.INPB") #! Field("PPS:SYSE:1:RSY_SECURE_A_calc.OUT",16777215,1,"PPS:SYSE:1:RSY_SECURE_A_calc.OUT") #! Link("PPS:SYSE:1:RSY_SECURE_A_calc.OUT","PPS:SYSE:1:RSY_SECURE_A.VAL") #! Record("PPS:SYSE:1:RSY_SECURE_A",500,20,0,0,"PPS:SYSE:1:RSY_SECURE_A") #! Field("PPS:SYSE:1:RSY_SECURE_A.VAL",16777215,1,"PPS:SYSE:1:RSY_SECURE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi109") { field(DESC, "Port 30BSY_RDA bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 109, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:SPARE_4_i6_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SPARE_4_i6_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SPARE_4_i6_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SPARE_4_i6_A") { field(DESC, "Spare 4.i6 A") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb109",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb109") #! Field("PLC:BSY0:PP09:30BSY_RDAb109.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb109.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb109.FLNK","PPS:SYSE:1:SPARE_4_i6_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb109.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb109.VAL") #! Record("PPS:SYSE:1:SPARE_4_i6_A_calc",260,18,0,1,"PPS:SYSE:1:SPARE_4_i6_A_calc") #! Field("PPS:SYSE:1:SPARE_4_i6_A_calc.INPA",16777215,0,"PPS:SYSE:1:SPARE_4_i6_A_calc.INPA") #! Link("PPS:SYSE:1:SPARE_4_i6_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb109.VAL") #! Field("PPS:SYSE:1:SPARE_4_i6_A_calc.INPB",16777215,1,"PPS:SYSE:1:SPARE_4_i6_A_calc.INPB") #! Field("PPS:SYSE:1:SPARE_4_i6_A_calc.OUT",16777215,1,"PPS:SYSE:1:SPARE_4_i6_A_calc.OUT") #! Link("PPS:SYSE:1:SPARE_4_i6_A_calc.OUT","PPS:SYSE:1:SPARE_4_i6_A.VAL") #! Record("PPS:SYSE:1:SPARE_4_i6_A",500,20,0,0,"PPS:SYSE:1:SPARE_4_i6_A") #! Field("PPS:SYSE:1:SPARE_4_i6_A.VAL",16777215,1,"PPS:SYSE:1:SPARE_4_i6_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi108") { field(DESC, "Port 30BSY_RDA bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 108, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:SPARE_4_i7_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SPARE_4_i7_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SPARE_4_i7_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SPARE_4_i7_A") { field(DESC, "Spare 4.i7 A") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb108",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb108") #! Field("PLC:BSY0:PP09:30BSY_RDAb108.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb108.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb108.FLNK","PPS:SYSE:1:SPARE_4_i7_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb108.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb108.VAL") #! Record("PPS:SYSE:1:SPARE_4_i7_A_calc",260,18,0,1,"PPS:SYSE:1:SPARE_4_i7_A_calc") #! Field("PPS:SYSE:1:SPARE_4_i7_A_calc.INPA",16777215,0,"PPS:SYSE:1:SPARE_4_i7_A_calc.INPA") #! Link("PPS:SYSE:1:SPARE_4_i7_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb108.VAL") #! Field("PPS:SYSE:1:SPARE_4_i7_A_calc.INPB",16777215,1,"PPS:SYSE:1:SPARE_4_i7_A_calc.INPB") #! Field("PPS:SYSE:1:SPARE_4_i7_A_calc.OUT",16777215,1,"PPS:SYSE:1:SPARE_4_i7_A_calc.OUT") #! Link("PPS:SYSE:1:SPARE_4_i7_A_calc.OUT","PPS:SYSE:1:SPARE_4_i7_A.VAL") #! Record("PPS:SYSE:1:SPARE_4_i7_A",500,20,0,0,"PPS:SYSE:1:SPARE_4_i7_A") #! Field("PPS:SYSE:1:SPARE_4_i7_A.VAL",16777215,1,"PPS:SYSE:1:SPARE_4_i7_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi107") { field(DESC, "Port 30BSY_RDA bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 107, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:SYSE:2:30BSY:SECURE_COM_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:2:30BSY:SECURE_COM_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:2:30BSY:SECURE_COM_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:2:30BSY:SECURE_COM_A") { field(DESC, "30-BSY Sec. Comp. (test mode)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb107",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb107") #! Field("PLC:BSY0:PP09:30BSY_RDAb107.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb107.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb107.FLNK","PPS:SYSE:2:30BSY:SECURE_COM_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb107.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb107.VAL") #! Record("PPS:SYSE:2:30BSY:SECURE_COM_A_calc",260,18,0,1,"PPS:SYSE:2:30BSY:SECURE_COM_A_calc") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_A_calc.INPA",16777215,0,"PPS:SYSE:2:30BSY:SECURE_COM_A_calc.INPA") #! Link("PPS:SYSE:2:30BSY:SECURE_COM_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb107.VAL") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_A_calc.INPB",16777215,1,"PPS:SYSE:2:30BSY:SECURE_COM_A_calc.INPB") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_A_calc.OUT",16777215,1,"PPS:SYSE:2:30BSY:SECURE_COM_A_calc.OUT") #! Link("PPS:SYSE:2:30BSY:SECURE_COM_A_calc.OUT","PPS:SYSE:2:30BSY:SECURE_COM_A.VAL") #! Record("PPS:SYSE:2:30BSY:SECURE_COM_A",500,20,0,0,"PPS:SYSE:2:30BSY:SECURE_COM_A") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_A.VAL",16777215,1,"PPS:SYSE:2:30BSY:SECURE_COM_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi106") { field(DESC, "Port 30BSY_RDA bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 106, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:SYSE:3:30BSY:SECURE_COM_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:3:30BSY:SECURE_COM_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:3:30BSY:SECURE_COM_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:3:30BSY:SECURE_COM_A") { field(DESC, "30-BSY Sec. Comp. (other ch.)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb106",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb106") #! Field("PLC:BSY0:PP09:30BSY_RDAb106.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb106.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb106.FLNK","PPS:SYSE:3:30BSY:SECURE_COM_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb106.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb106.VAL") #! Record("PPS:SYSE:3:30BSY:SECURE_COM_A_calc",260,18,0,1,"PPS:SYSE:3:30BSY:SECURE_COM_A_calc") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_A_calc.INPA",16777215,0,"PPS:SYSE:3:30BSY:SECURE_COM_A_calc.INPA") #! Link("PPS:SYSE:3:30BSY:SECURE_COM_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb106.VAL") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_A_calc.INPB",16777215,1,"PPS:SYSE:3:30BSY:SECURE_COM_A_calc.INPB") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_A_calc.OUT",16777215,1,"PPS:SYSE:3:30BSY:SECURE_COM_A_calc.OUT") #! Link("PPS:SYSE:3:30BSY:SECURE_COM_A_calc.OUT","PPS:SYSE:3:30BSY:SECURE_COM_A.VAL") #! Record("PPS:SYSE:3:30BSY:SECURE_COM_A",500,20,0,0,"PPS:SYSE:3:30BSY:SECURE_COM_A") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_A.VAL",16777215,1,"PPS:SYSE:3:30BSY:SECURE_COM_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi105") { field(DESC, "Port 30BSY_RDA bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 105, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HWALRMWARN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HWALRMWARN_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HWALRMWARN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HWALRMWARN_A") { field(DESC, "HW_Alarm_Warning_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb105",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb105") #! Field("PLC:BSY0:PP09:30BSY_RDAb105.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb105.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb105.FLNK","PPS:SYSE:1:30BSY:HWALRMWARN_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb105.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb105.VAL") #! Record("PPS:SYSE:1:30BSY:HWALRMWARN_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HWALRMWARN_A_calc") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb105.VAL") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HWALRMWARN_A_calc.OUT","PPS:SYSE:1:30BSY:HWALRMWARN_A.VAL") #! Record("PPS:SYSE:1:30BSY:HWALRMWARN_A",500,20,0,0,"PPS:SYSE:1:30BSY:HWALRMWARN_A") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:HWALRMWARN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi104") { field(DESC, "Port 30BSY_RDA bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 104, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_OUTP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_OUTP_A") { field(DESC, "PLC_Heartbeat_Output_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb104",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb104") #! Field("PLC:BSY0:PP09:30BSY_RDAb104.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb104.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb104.FLNK","PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb104.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb104.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb104.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_OUTP_A_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_OUTP_A.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OUTP_A",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_OUTP_A") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi119") { field(DESC, "Port 30BSY_RDA bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 119, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A") { field(DESC, "BCS_Fault_Trigger_Output_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb119",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb119") #! Field("PLC:BSY0:PP09:30BSY_RDAb119.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb119.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb119.FLNK","PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb119.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb119.VAL") #! Record("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb119.VAL") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A_calc.OUT","PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A.VAL") #! Record("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A",500,20,0,0,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi117") { field(DESC, "Port 30BSY_RDA bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 117, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:30BSY:SECURE_COM_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:SECURE_COM_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi117 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:SECURE_COM_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:SECURE_COM_A") { field(DESC, "30BSY_Secure_Complete_A") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb117",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb117") #! Field("PLC:BSY0:PP09:30BSY_RDAb117.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb117.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb117.FLNK","PPS:SYSE:1:30BSY:SECURE_COM_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb117.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb117.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_COM_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:SECURE_COM_A_calc") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:SECURE_COM_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:SECURE_COM_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb117.VAL") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:SECURE_COM_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:SECURE_COM_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:SECURE_COM_A_calc.OUT","PPS:SYSE:1:30BSY:SECURE_COM_A.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_COM_A",500,20,0,0,"PPS:SYSE:1:30BSY:SECURE_COM_A") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:SECURE_COM_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi116") { field(DESC, "Port 30BSY_RDA bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:SECURE_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:SECURE_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:SECURE_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:SECURE_LTH_A") { field(DESC, "30BSY_Secure_Latched_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb116",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb116") #! Field("PLC:BSY0:PP09:30BSY_RDAb116.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb116.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb116.FLNK","PPS:SYSE:1:30BSY:SECURE_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb116.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb116.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:SECURE_LTH_A_calc") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb116.VAL") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:SECURE_LTH_A_calc.OUT","PPS:SYSE:1:30BSY:SECURE_LTH_A.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_LTH_A",500,20,0,0,"PPS:SYSE:1:30BSY:SECURE_LTH_A") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:SECURE_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi115") { field(DESC, "Port 30BSY_RDA bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 115, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:LTU0:1:ACCPERMIT_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LTU0:1:ACCPERMIT_OUT_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LTU0:1:ACCPERMIT_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LTU0:1:ACCPERMIT_OUT_A") { field(DESC, "BTH_UND_Access_Permit_Out_A") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb115",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb115") #! Field("PLC:BSY0:PP09:30BSY_RDAb115.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb115.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb115.FLNK","PPS:LTU0:1:ACCPERMIT_OUT_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb115.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb115.VAL") #! Record("PPS:LTU0:1:ACCPERMIT_OUT_A_calc",260,18,0,1,"PPS:LTU0:1:ACCPERMIT_OUT_A_calc") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_A_calc.INPA",16777215,0,"PPS:LTU0:1:ACCPERMIT_OUT_A_calc.INPA") #! Link("PPS:LTU0:1:ACCPERMIT_OUT_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb115.VAL") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_A_calc.INPB",16777215,1,"PPS:LTU0:1:ACCPERMIT_OUT_A_calc.INPB") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_A_calc.OUT",16777215,1,"PPS:LTU0:1:ACCPERMIT_OUT_A_calc.OUT") #! Link("PPS:LTU0:1:ACCPERMIT_OUT_A_calc.OUT","PPS:LTU0:1:ACCPERMIT_OUT_A.VAL") #! Record("PPS:LTU0:1:ACCPERMIT_OUT_A",500,20,0,0,"PPS:LTU0:1:ACCPERMIT_OUT_A") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_A.VAL",16777215,1,"PPS:LTU0:1:ACCPERMIT_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi114") { field(DESC, "Port 30BSY_RDA bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 114, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:LTU0:2:ACCPERMIT_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LTU0:2:ACCPERMIT_OUT_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LTU0:2:ACCPERMIT_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LTU0:2:ACCPERMIT_OUT_A") { field(DESC, "RSY_Access_Permit_Out_A") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb114",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb114") #! Field("PLC:BSY0:PP09:30BSY_RDAb114.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb114.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb114.FLNK","PPS:LTU0:2:ACCPERMIT_OUT_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb114.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb114.VAL") #! Record("PPS:LTU0:2:ACCPERMIT_OUT_A_calc",260,18,0,1,"PPS:LTU0:2:ACCPERMIT_OUT_A_calc") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_A_calc.INPA",16777215,0,"PPS:LTU0:2:ACCPERMIT_OUT_A_calc.INPA") #! Link("PPS:LTU0:2:ACCPERMIT_OUT_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb114.VAL") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_A_calc.INPB",16777215,1,"PPS:LTU0:2:ACCPERMIT_OUT_A_calc.INPB") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_A_calc.OUT",16777215,1,"PPS:LTU0:2:ACCPERMIT_OUT_A_calc.OUT") #! Link("PPS:LTU0:2:ACCPERMIT_OUT_A_calc.OUT","PPS:LTU0:2:ACCPERMIT_OUT_A.VAL") #! Record("PPS:LTU0:2:ACCPERMIT_OUT_A",500,20,0,0,"PPS:LTU0:2:ACCPERMIT_OUT_A") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_A.VAL",16777215,1,"PPS:LTU0:2:ACCPERMIT_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi113") { field(DESC, "Port 30BSY_RDA bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 113, 1, 1)") field(ZNAM, "Not_Escalated") field(ONAM, "Escalated") field(FLNK, "PPS:SYSE:1:BSOIC_ESC_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BSOIC_ESC_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BSOIC_ESC_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BSOIC_ESC_A") { field(DESC, "BSOIC escalation A") field(ZNAM, "Not_Escalated") field(ONAM, "Escalated") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb113",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb113") #! Field("PLC:BSY0:PP09:30BSY_RDAb113.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb113.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb113.FLNK","PPS:SYSE:1:BSOIC_ESC_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb113.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb113.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_A_calc",260,18,0,1,"PPS:SYSE:1:BSOIC_ESC_A_calc") #! Field("PPS:SYSE:1:BSOIC_ESC_A_calc.INPA",16777215,0,"PPS:SYSE:1:BSOIC_ESC_A_calc.INPA") #! Link("PPS:SYSE:1:BSOIC_ESC_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb113.VAL") #! Field("PPS:SYSE:1:BSOIC_ESC_A_calc.INPB",16777215,1,"PPS:SYSE:1:BSOIC_ESC_A_calc.INPB") #! Field("PPS:SYSE:1:BSOIC_ESC_A_calc.OUT",16777215,1,"PPS:SYSE:1:BSOIC_ESC_A_calc.OUT") #! Link("PPS:SYSE:1:BSOIC_ESC_A_calc.OUT","PPS:SYSE:1:BSOIC_ESC_A.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_A",500,20,0,0,"PPS:SYSE:1:BSOIC_ESC_A") #! Field("PPS:SYSE:1:BSOIC_ESC_A.VAL",16777215,1,"PPS:SYSE:1:BSOIC_ESC_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi112") { field(DESC, "Port 30BSY_RDA bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 112, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi112 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:GLOBAL:BEAMCOND_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:GLOBAL:BEAMCOND_A") { field(DESC, "Global_Beam_Conditions_A") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb112",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb112") #! Field("PLC:BSY0:PP09:30BSY_RDAb112.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb112.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb112.FLNK","PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb112.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb112.VAL") #! Record("PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc",260,18,0,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.INPA",16777215,0,"PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.INPA") #! Link("PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb112.VAL") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.INPB",16777215,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.INPB") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.OUT",16777215,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.OUT") #! Link("PPS:SYSE:1:GLOBAL:BEAMCOND_A_calc.OUT","PPS:SYSE:1:GLOBAL:BEAMCOND_A.VAL") #! Record("PPS:SYSE:1:GLOBAL:BEAMCOND_A",500,20,0,0,"PPS:SYSE:1:GLOBAL:BEAMCOND_A") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_A.VAL",16777215,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi127") { field(DESC, "Port 30BSY_RDA bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 127, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:CU:BEAMCOND_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:BEAMCOND_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:BEAMCOND_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:BEAMCOND_A") { field(DESC, "Cu_Beam_Conditions_A") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb127",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb127") #! Field("PLC:BSY0:PP09:30BSY_RDAb127.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb127.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb127.FLNK","PPS:SYSE:1:CU:BEAMCOND_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb127.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb127.VAL") #! Record("PPS:SYSE:1:CU:BEAMCOND_A_calc",260,18,0,1,"PPS:SYSE:1:CU:BEAMCOND_A_calc") #! Field("PPS:SYSE:1:CU:BEAMCOND_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:BEAMCOND_A_calc.INPA") #! Link("PPS:SYSE:1:CU:BEAMCOND_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb127.VAL") #! Field("PPS:SYSE:1:CU:BEAMCOND_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:BEAMCOND_A_calc.INPB") #! Field("PPS:SYSE:1:CU:BEAMCOND_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:BEAMCOND_A_calc.OUT") #! Link("PPS:SYSE:1:CU:BEAMCOND_A_calc.OUT","PPS:SYSE:1:CU:BEAMCOND_A.VAL") #! Record("PPS:SYSE:1:CU:BEAMCOND_A",500,20,0,0,"PPS:SYSE:1:CU:BEAMCOND_A") #! Field("PPS:SYSE:1:CU:BEAMCOND_A.VAL",16777215,1,"PPS:SYSE:1:CU:BEAMCOND_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi126") { field(DESC, "Port 30BSY_RDA bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 126, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:SC:BEAMCOND_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SC:BEAMCOND_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi126 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SC:BEAMCOND_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SC:BEAMCOND_A") { field(DESC, "SC_Beam_Conditions_A") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb126",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb126") #! Field("PLC:BSY0:PP09:30BSY_RDAb126.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb126.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb126.FLNK","PPS:SYSE:1:SC:BEAMCOND_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb126.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb126.VAL") #! Record("PPS:SYSE:1:SC:BEAMCOND_A_calc",260,18,0,1,"PPS:SYSE:1:SC:BEAMCOND_A_calc") #! Field("PPS:SYSE:1:SC:BEAMCOND_A_calc.INPA",16777215,0,"PPS:SYSE:1:SC:BEAMCOND_A_calc.INPA") #! Link("PPS:SYSE:1:SC:BEAMCOND_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb126.VAL") #! Field("PPS:SYSE:1:SC:BEAMCOND_A_calc.INPB",16777215,1,"PPS:SYSE:1:SC:BEAMCOND_A_calc.INPB") #! Field("PPS:SYSE:1:SC:BEAMCOND_A_calc.OUT",16777215,1,"PPS:SYSE:1:SC:BEAMCOND_A_calc.OUT") #! Link("PPS:SYSE:1:SC:BEAMCOND_A_calc.OUT","PPS:SYSE:1:SC:BEAMCOND_A.VAL") #! Record("PPS:SYSE:1:SC:BEAMCOND_A",500,20,0,0,"PPS:SYSE:1:SC:BEAMCOND_A") #! Field("PPS:SYSE:1:SC:BEAMCOND_A.VAL",16777215,1,"PPS:SYSE:1:SC:BEAMCOND_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi123") { field(DESC, "Port 30BSY_RDA bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 123, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:BLM_INP_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BLM_INP_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BLM_INP_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BLM_INP_LTH_A") { field(DESC, "BCS_BLM_Input_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb123",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb123") #! Field("PLC:BSY0:PP09:30BSY_RDAb123.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb123.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb123.FLNK","PPS:SYSE:1:BLM_INP_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb123.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb123.VAL") #! Record("PPS:SYSE:1:BLM_INP_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:BLM_INP_LTH_A_calc") #! Field("PPS:SYSE:1:BLM_INP_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:BLM_INP_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:BLM_INP_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb123.VAL") #! Field("PPS:SYSE:1:BLM_INP_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:BLM_INP_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:BLM_INP_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:BLM_INP_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:BLM_INP_LTH_A_calc.OUT","PPS:SYSE:1:BLM_INP_LTH_A.VAL") #! Record("PPS:SYSE:1:BLM_INP_LTH_A",500,20,0,0,"PPS:SYSE:1:BLM_INP_LTH_A") #! Field("PPS:SYSE:1:BLM_INP_LTH_A.VAL",16777215,1,"PPS:SYSE:1:BLM_INP_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi121") { field(DESC, "Port 30BSY_RDA bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 121, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI30:1:SECURE_INP_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SECURE_INP_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SECURE_INP_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SECURE_INP_LTH_A") { field(DESC, "S30_Secure_Input_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb121",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb121") #! Field("PLC:BSY0:PP09:30BSY_RDAb121.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb121.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb121.FLNK","PPS:LI30:1:SECURE_INP_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb121.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb121.VAL") #! Record("PPS:LI30:1:SECURE_INP_LTH_A_calc",260,18,0,1,"PPS:LI30:1:SECURE_INP_LTH_A_calc") #! Field("PPS:LI30:1:SECURE_INP_LTH_A_calc.INPA",16777215,0,"PPS:LI30:1:SECURE_INP_LTH_A_calc.INPA") #! Link("PPS:LI30:1:SECURE_INP_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb121.VAL") #! Field("PPS:LI30:1:SECURE_INP_LTH_A_calc.INPB",16777215,1,"PPS:LI30:1:SECURE_INP_LTH_A_calc.INPB") #! Field("PPS:LI30:1:SECURE_INP_LTH_A_calc.OUT",16777215,1,"PPS:LI30:1:SECURE_INP_LTH_A_calc.OUT") #! Link("PPS:LI30:1:SECURE_INP_LTH_A_calc.OUT","PPS:LI30:1:SECURE_INP_LTH_A.VAL") #! Record("PPS:LI30:1:SECURE_INP_LTH_A",500,20,0,0,"PPS:LI30:1:SECURE_INP_LTH_A") #! Field("PPS:LI30:1:SECURE_INP_LTH_A.VAL",16777215,1,"PPS:LI30:1:SECURE_INP_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi120") { field(DESC, "Port 30BSY_RDA bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 120, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSY0:1:SECURE_INP_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSY0:1:SECURE_INP_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSY0:1:SECURE_INP_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSY0:1:SECURE_INP_LTH_A") { field(DESC, "BSY_Secure_Input_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb120",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb120") #! Field("PLC:BSY0:PP09:30BSY_RDAb120.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb120.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb120.FLNK","PPS:BSY0:1:SECURE_INP_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb120.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb120.VAL") #! Record("PPS:BSY0:1:SECURE_INP_LTH_A_calc",260,18,0,1,"PPS:BSY0:1:SECURE_INP_LTH_A_calc") #! Field("PPS:BSY0:1:SECURE_INP_LTH_A_calc.INPA",16777215,0,"PPS:BSY0:1:SECURE_INP_LTH_A_calc.INPA") #! Link("PPS:BSY0:1:SECURE_INP_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb120.VAL") #! Field("PPS:BSY0:1:SECURE_INP_LTH_A_calc.INPB",16777215,1,"PPS:BSY0:1:SECURE_INP_LTH_A_calc.INPB") #! Field("PPS:BSY0:1:SECURE_INP_LTH_A_calc.OUT",16777215,1,"PPS:BSY0:1:SECURE_INP_LTH_A_calc.OUT") #! Link("PPS:BSY0:1:SECURE_INP_LTH_A_calc.OUT","PPS:BSY0:1:SECURE_INP_LTH_A.VAL") #! Record("PPS:BSY0:1:SECURE_INP_LTH_A",500,20,0,0,"PPS:BSY0:1:SECURE_INP_LTH_A") #! Field("PPS:BSY0:1:SECURE_INP_LTH_A.VAL",16777215,1,"PPS:BSY0:1:SECURE_INP_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi135") { field(DESC, "Port 30BSY_RDA bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 135, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:ESA0:1:RADREADY_INP_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:ESA0:1:RADREADY_INP_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:ESA0:1:RADREADY_INP_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:ESA0:1:RADREADY_INP_LTH_A") { field(DESC, "ESA_Rad_Ready_Input_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb135",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb135") #! Field("PLC:BSY0:PP09:30BSY_RDAb135.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb135.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb135.FLNK","PPS:ESA0:1:RADREADY_INP_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb135.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb135.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_LTH_A_calc",260,18,0,1,"PPS:ESA0:1:RADREADY_INP_LTH_A_calc") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_A_calc.INPA",16777215,0,"PPS:ESA0:1:RADREADY_INP_LTH_A_calc.INPA") #! Link("PPS:ESA0:1:RADREADY_INP_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb135.VAL") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_A_calc.INPB",16777215,1,"PPS:ESA0:1:RADREADY_INP_LTH_A_calc.INPB") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_A_calc.OUT",16777215,1,"PPS:ESA0:1:RADREADY_INP_LTH_A_calc.OUT") #! Link("PPS:ESA0:1:RADREADY_INP_LTH_A_calc.OUT","PPS:ESA0:1:RADREADY_INP_LTH_A.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_LTH_A",500,20,0,0,"PPS:ESA0:1:RADREADY_INP_LTH_A") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_A.VAL",16777215,1,"PPS:ESA0:1:RADREADY_INP_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi134") { field(DESC, "Port 30BSY_RDA bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 134, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:SUM_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SUM_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SUM_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SUM_OK_LTH_A") { field(DESC, "BTM_Sum_OK_Input_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb134",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb134") #! Field("PLC:BSY0:PP09:30BSY_RDAb134.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb134.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb134.FLNK","BTM:BSY0:1:SUM_OK_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb134.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb134.VAL") #! Record("BTM:BSY0:1:SUM_OK_LTH_A_calc",260,18,0,1,"BTM:BSY0:1:SUM_OK_LTH_A_calc") #! Field("BTM:BSY0:1:SUM_OK_LTH_A_calc.INPA",16777215,0,"BTM:BSY0:1:SUM_OK_LTH_A_calc.INPA") #! Link("BTM:BSY0:1:SUM_OK_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb134.VAL") #! Field("BTM:BSY0:1:SUM_OK_LTH_A_calc.INPB",16777215,1,"BTM:BSY0:1:SUM_OK_LTH_A_calc.INPB") #! Field("BTM:BSY0:1:SUM_OK_LTH_A_calc.OUT",16777215,1,"BTM:BSY0:1:SUM_OK_LTH_A_calc.OUT") #! Link("BTM:BSY0:1:SUM_OK_LTH_A_calc.OUT","BTM:BSY0:1:SUM_OK_LTH_A.VAL") #! Record("BTM:BSY0:1:SUM_OK_LTH_A",500,20,0,0,"BTM:BSY0:1:SUM_OK_LTH_A") #! Field("BTM:BSY0:1:SUM_OK_LTH_A.VAL",16777215,1,"BTM:BSY0:1:SUM_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi133") { field(DESC, "Port 30BSY_RDA bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 133, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BSOC:SYSE:1:GROUPC_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:SYSE:1:GROUPC_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:SYSE:1:GROUPC_LTH_A PP MS") field(ASG, "Internal") } record(bi, "BSOC:SYSE:1:GROUPC_LTH_A") { field(DESC, "BSOIC_GrpC_OK_Input_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb133",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb133") #! Field("PLC:BSY0:PP09:30BSY_RDAb133.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb133.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb133.FLNK","BSOC:SYSE:1:GROUPC_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb133.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb133.VAL") #! Record("BSOC:SYSE:1:GROUPC_LTH_A_calc",260,18,0,1,"BSOC:SYSE:1:GROUPC_LTH_A_calc") #! Field("BSOC:SYSE:1:GROUPC_LTH_A_calc.INPA",16777215,0,"BSOC:SYSE:1:GROUPC_LTH_A_calc.INPA") #! Link("BSOC:SYSE:1:GROUPC_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb133.VAL") #! Field("BSOC:SYSE:1:GROUPC_LTH_A_calc.INPB",16777215,1,"BSOC:SYSE:1:GROUPC_LTH_A_calc.INPB") #! Field("BSOC:SYSE:1:GROUPC_LTH_A_calc.OUT",16777215,1,"BSOC:SYSE:1:GROUPC_LTH_A_calc.OUT") #! Link("BSOC:SYSE:1:GROUPC_LTH_A_calc.OUT","BSOC:SYSE:1:GROUPC_LTH_A.VAL") #! Record("BSOC:SYSE:1:GROUPC_LTH_A",500,20,0,0,"BSOC:SYSE:1:GROUPC_LTH_A") #! Field("BSOC:SYSE:1:GROUPC_LTH_A.VAL",16777215,1,"BSOC:SYSE:1:GROUPC_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi132") { field(DESC, "Port 30BSY_RDA bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 132, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:UND0:1:SECURE_INP_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:UND0:1:SECURE_INP_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:UND0:1:SECURE_INP_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:UND0:1:SECURE_INP_LTH_A") { field(DESC, "LCLS_Secure_Input_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb132",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb132") #! Field("PLC:BSY0:PP09:30BSY_RDAb132.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb132.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb132.FLNK","PPS:UND0:1:SECURE_INP_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb132.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb132.VAL") #! Record("PPS:UND0:1:SECURE_INP_LTH_A_calc",260,18,0,1,"PPS:UND0:1:SECURE_INP_LTH_A_calc") #! Field("PPS:UND0:1:SECURE_INP_LTH_A_calc.INPA",16777215,0,"PPS:UND0:1:SECURE_INP_LTH_A_calc.INPA") #! Link("PPS:UND0:1:SECURE_INP_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb132.VAL") #! Field("PPS:UND0:1:SECURE_INP_LTH_A_calc.INPB",16777215,1,"PPS:UND0:1:SECURE_INP_LTH_A_calc.INPB") #! Field("PPS:UND0:1:SECURE_INP_LTH_A_calc.OUT",16777215,1,"PPS:UND0:1:SECURE_INP_LTH_A_calc.OUT") #! Link("PPS:UND0:1:SECURE_INP_LTH_A_calc.OUT","PPS:UND0:1:SECURE_INP_LTH_A.VAL") #! Record("PPS:UND0:1:SECURE_INP_LTH_A",500,20,0,0,"PPS:UND0:1:SECURE_INP_LTH_A") #! Field("PPS:UND0:1:SECURE_INP_LTH_A.VAL",16777215,1,"PPS:UND0:1:SECURE_INP_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi131") { field(DESC, "Port 30BSY_RDA bit 131") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 131, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi131 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A") { field(DESC, "Local_Beam_Enable_Keysw_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb131",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb131") #! Field("PLC:BSY0:PP09:30BSY_RDAb131.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb131.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb131.FLNK","PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb131.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb131.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb131.VAL") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A_calc.OUT","PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A",500,20,0,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi130") { field(DESC, "Port 30BSY_RDA bit 130") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 130, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:BSOIC_ESC_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BSOIC_ESC_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi130 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BSOIC_ESC_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BSOIC_ESC_LTH_A") { field(DESC, "BSOIC escalation Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb130",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb130") #! Field("PLC:BSY0:PP09:30BSY_RDAb130.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb130.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb130.FLNK","PPS:SYSE:1:BSOIC_ESC_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb130.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb130.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:BSOIC_ESC_LTH_A_calc") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb130.VAL") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:BSOIC_ESC_LTH_A_calc.OUT","PPS:SYSE:1:BSOIC_ESC_LTH_A.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_LTH_A",500,20,0,0,"PPS:SYSE:1:BSOIC_ESC_LTH_A") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_A.VAL",16777215,1,"PPS:SYSE:1:BSOIC_ESC_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi129") { field(DESC, "Port 30BSY_RDA bit 129") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 129, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:BCS_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BCS_FAULT_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi129 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BCS_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BCS_FAULT_LTH_A") { field(DESC, "BCS BEAM ON Fault A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb129",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb129") #! Field("PLC:BSY0:PP09:30BSY_RDAb129.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb129.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb129.FLNK","PPS:SYSE:1:BCS_FAULT_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb129.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb129.VAL") #! Record("PPS:SYSE:1:BCS_FAULT_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:BCS_FAULT_LTH_A_calc") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:BCS_FAULT_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:BCS_FAULT_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb129.VAL") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:BCS_FAULT_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:BCS_FAULT_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:BCS_FAULT_LTH_A_calc.OUT","PPS:SYSE:1:BCS_FAULT_LTH_A.VAL") #! Record("PPS:SYSE:1:BCS_FAULT_LTH_A",500,20,0,0,"PPS:SYSE:1:BCS_FAULT_LTH_A") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_A.VAL",16777215,1,"PPS:SYSE:1:BCS_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi128") { field(DESC, "Port 30BSY_RDA bit 128") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 128, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi128 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A") { field(DESC, "ACR_Beam_Enable_Keysw_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb128",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb128") #! Field("PLC:BSY0:PP09:30BSY_RDAb128.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb128.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb128.FLNK","PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb128.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb128.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb128.VAL") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A_calc.OUT","PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A",500,20,0,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi143") { field(DESC, "Port 30BSY_RDA bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 143, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:INTLK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:INTLK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:INTLK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:INTLK_LTH_A") { field(DESC, "30-BSY Glbl. intlk (spare) A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb143",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb143") #! Field("PLC:BSY0:PP09:30BSY_RDAb143.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb143.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb143.FLNK","PPS:SYSE:1:30BSY:INTLK_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb143.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb143.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:INTLK_LTH_A_calc") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb143.VAL") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:INTLK_LTH_A_calc.OUT","PPS:SYSE:1:30BSY:INTLK_LTH_A.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_LTH_A",500,20,0,0,"PPS:SYSE:1:30BSY:INTLK_LTH_A") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:INTLK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi142") { field(DESC, "Port 30BSY_RDA bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 142, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:CU:BEAMOK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:BEAMOK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:BEAMOK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:BEAMOK_LTH_A") { field(DESC, "Cu beam config OK (spare) A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb142",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb142") #! Field("PLC:BSY0:PP09:30BSY_RDAb142.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb142.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb142.FLNK","PPS:SYSE:1:CU:BEAMOK_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb142.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb142.VAL") #! Record("PPS:SYSE:1:CU:BEAMOK_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:CU:BEAMOK_LTH_A_calc") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb142.VAL") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:CU:BEAMOK_LTH_A_calc.OUT","PPS:SYSE:1:CU:BEAMOK_LTH_A.VAL") #! Record("PPS:SYSE:1:CU:BEAMOK_LTH_A",500,20,0,0,"PPS:SYSE:1:CU:BEAMOK_LTH_A") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_A.VAL",16777215,1,"PPS:SYSE:1:CU:BEAMOK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi141") { field(DESC, "Port 30BSY_RDA bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 141, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:SC:BEAMOK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SC:BEAMOK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SC:BEAMOK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SC:BEAMOK_LTH_A") { field(DESC, "SC beam config OK (spare) A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb141",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb141") #! Field("PLC:BSY0:PP09:30BSY_RDAb141.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb141.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb141.FLNK","PPS:SYSE:1:SC:BEAMOK_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb141.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb141.VAL") #! Record("PPS:SYSE:1:SC:BEAMOK_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:SC:BEAMOK_LTH_A_calc") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb141.VAL") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:SC:BEAMOK_LTH_A_calc.OUT","PPS:SYSE:1:SC:BEAMOK_LTH_A.VAL") #! Record("PPS:SYSE:1:SC:BEAMOK_LTH_A",500,20,0,0,"PPS:SYSE:1:SC:BEAMOK_LTH_A") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_A.VAL",16777215,1,"PPS:SYSE:1:SC:BEAMOK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi139") { field(DESC, "Port 30BSY_RDA bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 139, 1, 1)") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_OK_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_OK_A") { field(DESC, "Heartbeat OK A") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb139",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb139") #! Field("PLC:BSY0:PP09:30BSY_RDAb139.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb139.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb139.FLNK","PPS:SYSE:1:30BSY:HRTBT_OK_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb139.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb139.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_OK_A_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb139.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_A_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_OK_A.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_A",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_OK_A") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi138") { field(DESC, "Port 30BSY_RDA bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:SYSE:1:INSERT_FAILED_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:SYSE:1:INSERT_FAILED_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:SYSE:1:INSERT_FAILED_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:SYSE:1:INSERT_FAILED_LTH_A") { field(DESC, "Stopper_Insert_Failed_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb138",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb138") #! Field("PLC:BSY0:PP09:30BSY_RDAb138.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb138.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb138.FLNK","STPR:SYSE:1:INSERT_FAILED_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb138.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb138.VAL") #! Record("STPR:SYSE:1:INSERT_FAILED_LTH_A_calc",260,18,0,1,"STPR:SYSE:1:INSERT_FAILED_LTH_A_calc") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.INPA",16777215,0,"STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.INPA") #! Link("STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb138.VAL") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.INPB",16777215,1,"STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.INPB") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.OUT",16777215,1,"STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.OUT") #! Link("STPR:SYSE:1:INSERT_FAILED_LTH_A_calc.OUT","STPR:SYSE:1:INSERT_FAILED_LTH_A.VAL") #! Record("STPR:SYSE:1:INSERT_FAILED_LTH_A",500,20,0,0,"STPR:SYSE:1:INSERT_FAILED_LTH_A") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_A.VAL",16777215,1,"STPR:SYSE:1:INSERT_FAILED_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi137") { field(DESC, "Port 30BSY_RDA bit 137") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 137, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi137 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A") { field(DESC, "Heartbeat OK Latched A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb137",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb137") #! Field("PLC:BSY0:PP09:30BSY_RDAb137.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb137.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb137.FLNK","PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb137.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb137.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb137.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi136") { field(DESC, "Port 30BSY_RDA bit 136") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 136, 1, 1)") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(FLNK, "PPS:SYSE:1:CU:HXR_CLEAR_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:HXR_CLEAR_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi136 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:HXR_CLEAR_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:HXR_CLEAR_A") { field(DESC, "Cu line cleared to HXR A") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb136",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb136") #! Field("PLC:BSY0:PP09:30BSY_RDAb136.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb136.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb136.FLNK","PPS:SYSE:1:CU:HXR_CLEAR_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb136.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb136.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_A_calc",260,18,0,1,"PPS:SYSE:1:CU:HXR_CLEAR_A_calc") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:HXR_CLEAR_A_calc.INPA") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb136.VAL") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_A_calc.INPB") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_A_calc.OUT") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_A_calc.OUT","PPS:SYSE:1:CU:HXR_CLEAR_A.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_A",500,20,0,0,"PPS:SYSE:1:CU:HXR_CLEAR_A") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_A.VAL",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi151") { field(DESC, "Port 30BSY_RDA bit 151") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 151, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi151 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_A") { field(DESC, "Cu line cleared to HXR Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb151",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb151") #! Field("PLC:BSY0:PP09:30BSY_RDAb151.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb151.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb151.FLNK","PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb151.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb151.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb151.VAL") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A_calc.OUT","PPS:SYSE:1:CU:HXR_CLEAR_LTH_A.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A",500,20,0,0,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_A") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_A.VAL",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi150") { field(DESC, "Port 30BSY_RDA bit 150") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 150, 1, 1)") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(FLNK, "PPS:SYSE:1:CU:SXR_CLEAR_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:SXR_CLEAR_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi150 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:SXR_CLEAR_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:SXR_CLEAR_A") { field(DESC, "Cu line cleared to SXR A") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb150",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb150") #! Field("PLC:BSY0:PP09:30BSY_RDAb150.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb150.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb150.FLNK","PPS:SYSE:1:CU:SXR_CLEAR_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb150.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb150.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_A_calc",260,18,0,1,"PPS:SYSE:1:CU:SXR_CLEAR_A_calc") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:SXR_CLEAR_A_calc.INPA") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb150.VAL") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_A_calc.INPB") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_A_calc.OUT") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_A_calc.OUT","PPS:SYSE:1:CU:SXR_CLEAR_A.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_A",500,20,0,0,"PPS:SYSE:1:CU:SXR_CLEAR_A") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_A.VAL",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP09:Bi149") { field(DESC, "Port 30BSY_RDA bit 149") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 149, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc") { field(INPA, "PLC:BSY0:PP09:Bi149 NPP MS") field(INPB, "PLC:BSY0:PP09:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_A") { field(DESC, "Cu line cleared to SXR Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP09:30BSY_RDAb149",20,19,0,0,"PLC:BSY0:PP09:30BSY_RDAb149") #! Field("PLC:BSY0:PP09:30BSY_RDAb149.FLNK",16777215,1,"PLC:BSY0:PP09:30BSY_RDAb149.FLNK") #! Link("PLC:BSY0:PP09:30BSY_RDAb149.FLNK","PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc") #! Field("PLC:BSY0:PP09:30BSY_RDAb149.VAL",16777215,0,"PLC:BSY0:PP09:30BSY_RDAb149.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc",260,18,0,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.INPA",16777215,0,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.INPA") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.INPA","PLC:BSY0:PP09:30BSY_RDAb149.VAL") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.INPB",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.INPB") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.OUT",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.OUT") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A_calc.OUT","PPS:SYSE:1:CU:SXR_CLEAR_LTH_A.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A",500,20,0,0,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_A") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_A.VAL",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_A.VAL") record(bo, "PPS:SYSE:1:30BSY:RESET_INTLK_A") { field(DESC, "PPS_Interlock_Reset_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:SYSE:1:30BSY:PAUSEHB_A") { field(DESC, "PPS_Pause_Heartbeat_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP09:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP09:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP09:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP09:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP09:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP09:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP09:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP09:REQ_SEG CP") field( INPC, "PLC:BSY0:PP09:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP09:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP09:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP09:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP09:REQ_SEG CP") field( INPC, "PLC:BSY0:PP09:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP09:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP09:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP09:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP09:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP09:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP09:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP09:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP09:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP09:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP09:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP09:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP09:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP09:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP09:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP09:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP09:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP09:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP09:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP09:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP09:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP09:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP09:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP09:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP09:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP09:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP09:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP09:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP09:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP09:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP09:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP09:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP09:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP09:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP09:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP09:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP09:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP09:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP09:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP09:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP09:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP09:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP09:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP09:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP09:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP09:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP09:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP09:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP09:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP09:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP09:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP09:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP09:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP09:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP09:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP09:w0") { field(DESC, "S30 BSY CHA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:w1") { field(DESC, "S30 BSY CHA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP09:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP09:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP09:w3") { field(DESC, "S30 BSY CHA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP09:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP09:w3 PP MS") field(INPB, "PLC:BSY0:PP09:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP09:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP09:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP09:w4") { field(DESC, "S30 BSY CHA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP09:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP09:w4 NPP MS") field(INPB, "PLC:BSY0:PP09:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP09:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP09:w5") { field(DESC, "S30 BSY CHA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP09:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP09:w5 NPP MS") field(INPB, "PLC:BSY0:PP09:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP09:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP09:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP09:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP09:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP09:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP09:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP09:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP09:w6 NPP MS") field(INPB, "PLC:BSY0:PP09:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP09:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP09:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP09:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP09:w7 NPP MS") field(INPB, "PLC:BSY0:PP09:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP09:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDA, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP09:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP09:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP09:w8 NPP MS") field(INPB, "PLC:BSY0:PP09:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP09:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP09:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP09:OP_HOURS") { field(INPA, "PLC:BSY0:PP09:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP09:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP09:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP09:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP09:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(30BSY_RDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP09:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP09:RDHist.PROC") } record(waveform,"PLC:BSY0:PP09:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_RDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP09:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP09:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_RDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP09:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP09:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(30BSY_RDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP09:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP09:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP09:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP09:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP09:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP09:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP09:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP09:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP09:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP09:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(30BSY_WRTA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP09:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP09:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP09:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WRTA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP09:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP09:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WRTA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP09:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP09:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(30BSY_WRTA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP09:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTA 0)READ_OK") field(FLNK,"PLC:BSY0:PP09:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP09:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP09:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP09:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP09:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP09:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP09:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP09:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP09:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(30BSY_WDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP09:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP09:WDHist.PROC") } record(waveform,"PLC:BSY0:PP09:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP09:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP09:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP09:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP09:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(30BSY_WDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP09:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP09:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP09:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP09:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP09:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP09:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP09:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP09:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP09:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDA 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi7") { field(DESC, "Port 30BSY_RDB bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 7, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:SYSE:1:HW_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:HW_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:HW_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:HW_ENABLE_B") { field(DESC, "HW Enabled B") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb7",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb7") #! Field("PLC:BSY0:PP10:30BSY_RDBb7.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb7.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb7.FLNK","PPS:SYSE:1:HW_ENABLE_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb7.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb7.VAL") #! Record("PPS:SYSE:1:HW_ENABLE_B_calc",260,18,0,1,"PPS:SYSE:1:HW_ENABLE_B_calc") #! Field("PPS:SYSE:1:HW_ENABLE_B_calc.INPA",16777215,0,"PPS:SYSE:1:HW_ENABLE_B_calc.INPA") #! Link("PPS:SYSE:1:HW_ENABLE_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb7.VAL") #! Field("PPS:SYSE:1:HW_ENABLE_B_calc.INPB",16777215,1,"PPS:SYSE:1:HW_ENABLE_B_calc.INPB") #! Field("PPS:SYSE:1:HW_ENABLE_B_calc.OUT",16777215,1,"PPS:SYSE:1:HW_ENABLE_B_calc.OUT") #! Link("PPS:SYSE:1:HW_ENABLE_B_calc.OUT","PPS:SYSE:1:HW_ENABLE_B.VAL") #! Record("PPS:SYSE:1:HW_ENABLE_B",500,20,0,0,"PPS:SYSE:1:HW_ENABLE_B") #! Field("PPS:SYSE:1:HW_ENABLE_B.VAL",16777215,1,"PPS:SYSE:1:HW_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi6") { field(DESC, "Port 30BSY_RDB bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:CROSS_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CROSS_INTLK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CROSS_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CROSS_INTLK_B") { field(DESC, "Secure Complete from Other Chain") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb6",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb6") #! Field("PLC:BSY0:PP10:30BSY_RDBb6.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb6.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb6.FLNK","PPS:SYSE:1:CROSS_INTLK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb6.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb6.VAL") #! Record("PPS:SYSE:1:CROSS_INTLK_B_calc",260,18,0,1,"PPS:SYSE:1:CROSS_INTLK_B_calc") #! Field("PPS:SYSE:1:CROSS_INTLK_B_calc.INPA",16777215,0,"PPS:SYSE:1:CROSS_INTLK_B_calc.INPA") #! Link("PPS:SYSE:1:CROSS_INTLK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb6.VAL") #! Field("PPS:SYSE:1:CROSS_INTLK_B_calc.INPB",16777215,1,"PPS:SYSE:1:CROSS_INTLK_B_calc.INPB") #! Field("PPS:SYSE:1:CROSS_INTLK_B_calc.OUT",16777215,1,"PPS:SYSE:1:CROSS_INTLK_B_calc.OUT") #! Link("PPS:SYSE:1:CROSS_INTLK_B_calc.OUT","PPS:SYSE:1:CROSS_INTLK_B.VAL") #! Record("PPS:SYSE:1:CROSS_INTLK_B",500,20,0,0,"PPS:SYSE:1:CROSS_INTLK_B") #! Field("PPS:SYSE:1:CROSS_INTLK_B.VAL",16777215,1,"PPS:SYSE:1:CROSS_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi5") { field(DESC, "Port 30BSY_RDB bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:BLM_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BLM_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BLM_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BLM_INP_B") { field(DESC, "BCS_BLM_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb5",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb5") #! Field("PLC:BSY0:PP10:30BSY_RDBb5.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb5.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb5.FLNK","PPS:SYSE:1:BLM_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb5.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb5.VAL") #! Record("PPS:SYSE:1:BLM_INP_B_calc",260,18,0,1,"PPS:SYSE:1:BLM_INP_B_calc") #! Field("PPS:SYSE:1:BLM_INP_B_calc.INPA",16777215,0,"PPS:SYSE:1:BLM_INP_B_calc.INPA") #! Link("PPS:SYSE:1:BLM_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb5.VAL") #! Field("PPS:SYSE:1:BLM_INP_B_calc.INPB",16777215,1,"PPS:SYSE:1:BLM_INP_B_calc.INPB") #! Field("PPS:SYSE:1:BLM_INP_B_calc.OUT",16777215,1,"PPS:SYSE:1:BLM_INP_B_calc.OUT") #! Link("PPS:SYSE:1:BLM_INP_B_calc.OUT","PPS:SYSE:1:BLM_INP_B.VAL") #! Record("PPS:SYSE:1:BLM_INP_B",500,20,0,0,"PPS:SYSE:1:BLM_INP_B") #! Field("PPS:SYSE:1:BLM_INP_B.VAL",16777215,1,"PPS:SYSE:1:BLM_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi3") { field(DESC, "Port 30BSY_RDB bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 3, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:LI30:1:SECURE_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SECURE_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi3 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SECURE_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SECURE_INP_B") { field(DESC, "S30_Secure_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb3",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb3") #! Field("PLC:BSY0:PP10:30BSY_RDBb3.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb3.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb3.FLNK","PPS:LI30:1:SECURE_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb3.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb3.VAL") #! Record("PPS:LI30:1:SECURE_INP_B_calc",260,18,0,1,"PPS:LI30:1:SECURE_INP_B_calc") #! Field("PPS:LI30:1:SECURE_INP_B_calc.INPA",16777215,0,"PPS:LI30:1:SECURE_INP_B_calc.INPA") #! Link("PPS:LI30:1:SECURE_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb3.VAL") #! Field("PPS:LI30:1:SECURE_INP_B_calc.INPB",16777215,1,"PPS:LI30:1:SECURE_INP_B_calc.INPB") #! Field("PPS:LI30:1:SECURE_INP_B_calc.OUT",16777215,1,"PPS:LI30:1:SECURE_INP_B_calc.OUT") #! Link("PPS:LI30:1:SECURE_INP_B_calc.OUT","PPS:LI30:1:SECURE_INP_B.VAL") #! Record("PPS:LI30:1:SECURE_INP_B",500,20,0,0,"PPS:LI30:1:SECURE_INP_B") #! Field("PPS:LI30:1:SECURE_INP_B.VAL",16777215,1,"PPS:LI30:1:SECURE_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi2") { field(DESC, "Port 30BSY_RDB bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSY0:1:SECURE_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSY0:1:SECURE_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSY0:1:SECURE_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSY0:1:SECURE_INP_B") { field(DESC, "BSY_Secure_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb2",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb2") #! Field("PLC:BSY0:PP10:30BSY_RDBb2.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb2.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb2.FLNK","PPS:BSY0:1:SECURE_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb2.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb2.VAL") #! Record("PPS:BSY0:1:SECURE_INP_B_calc",260,18,0,1,"PPS:BSY0:1:SECURE_INP_B_calc") #! Field("PPS:BSY0:1:SECURE_INP_B_calc.INPA",16777215,0,"PPS:BSY0:1:SECURE_INP_B_calc.INPA") #! Link("PPS:BSY0:1:SECURE_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb2.VAL") #! Field("PPS:BSY0:1:SECURE_INP_B_calc.INPB",16777215,1,"PPS:BSY0:1:SECURE_INP_B_calc.INPB") #! Field("PPS:BSY0:1:SECURE_INP_B_calc.OUT",16777215,1,"PPS:BSY0:1:SECURE_INP_B_calc.OUT") #! Link("PPS:BSY0:1:SECURE_INP_B_calc.OUT","PPS:BSY0:1:SECURE_INP_B.VAL") #! Record("PPS:BSY0:1:SECURE_INP_B",500,20,0,0,"PPS:BSY0:1:SECURE_INP_B") #! Field("PPS:BSY0:1:SECURE_INP_B.VAL",16777215,1,"PPS:BSY0:1:SECURE_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi1") { field(DESC, "Port 30BSY_RDB bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:ESA0:1:RADREADY_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:ESA0:1:RADREADY_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:ESA0:1:RADREADY_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:ESA0:1:RADREADY_INP_B") { field(DESC, "ESA_Rad_Ready_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb1",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb1") #! Field("PLC:BSY0:PP10:30BSY_RDBb1.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb1.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb1.FLNK","PPS:ESA0:1:RADREADY_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb1.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb1.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_B_calc",260,18,0,1,"PPS:ESA0:1:RADREADY_INP_B_calc") #! Field("PPS:ESA0:1:RADREADY_INP_B_calc.INPA",16777215,0,"PPS:ESA0:1:RADREADY_INP_B_calc.INPA") #! Link("PPS:ESA0:1:RADREADY_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb1.VAL") #! Field("PPS:ESA0:1:RADREADY_INP_B_calc.INPB",16777215,1,"PPS:ESA0:1:RADREADY_INP_B_calc.INPB") #! Field("PPS:ESA0:1:RADREADY_INP_B_calc.OUT",16777215,1,"PPS:ESA0:1:RADREADY_INP_B_calc.OUT") #! Link("PPS:ESA0:1:RADREADY_INP_B_calc.OUT","PPS:ESA0:1:RADREADY_INP_B.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_B",500,20,0,0,"PPS:ESA0:1:RADREADY_INP_B") #! Field("PPS:ESA0:1:RADREADY_INP_B.VAL",16777215,1,"PPS:ESA0:1:RADREADY_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi0") { field(DESC, "Port 30BSY_RDB bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 0, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BTM:BSY0:1:SUM_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SUM_OK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SUM_OK_B PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SUM_OK_B") { field(DESC, "BTM_Sum_OK_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb0",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb0") #! Field("PLC:BSY0:PP10:30BSY_RDBb0.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb0.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb0.FLNK","BTM:BSY0:1:SUM_OK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb0.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb0.VAL") #! Record("BTM:BSY0:1:SUM_OK_B_calc",260,18,0,1,"BTM:BSY0:1:SUM_OK_B_calc") #! Field("BTM:BSY0:1:SUM_OK_B_calc.INPA",16777215,0,"BTM:BSY0:1:SUM_OK_B_calc.INPA") #! Link("BTM:BSY0:1:SUM_OK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb0.VAL") #! Field("BTM:BSY0:1:SUM_OK_B_calc.INPB",16777215,1,"BTM:BSY0:1:SUM_OK_B_calc.INPB") #! Field("BTM:BSY0:1:SUM_OK_B_calc.OUT",16777215,1,"BTM:BSY0:1:SUM_OK_B_calc.OUT") #! Link("BTM:BSY0:1:SUM_OK_B_calc.OUT","BTM:BSY0:1:SUM_OK_B.VAL") #! Record("BTM:BSY0:1:SUM_OK_B",500,20,0,0,"BTM:BSY0:1:SUM_OK_B") #! Field("BTM:BSY0:1:SUM_OK_B.VAL",16777215,1,"BTM:BSY0:1:SUM_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi15") { field(DESC, "Port 30BSY_RDB bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:SYSE:1:GROUPC_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:SYSE:1:GROUPC_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:SYSE:1:GROUPC_B PP MS") field(ASG, "Internal") } record(bi, "BSOC:SYSE:1:GROUPC_B") { field(DESC, "BSOIC_GrpC_OK_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb15",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb15") #! Field("PLC:BSY0:PP10:30BSY_RDBb15.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb15.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb15.FLNK","BSOC:SYSE:1:GROUPC_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb15.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb15.VAL") #! Record("BSOC:SYSE:1:GROUPC_B_calc",260,18,0,1,"BSOC:SYSE:1:GROUPC_B_calc") #! Field("BSOC:SYSE:1:GROUPC_B_calc.INPA",16777215,0,"BSOC:SYSE:1:GROUPC_B_calc.INPA") #! Link("BSOC:SYSE:1:GROUPC_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb15.VAL") #! Field("BSOC:SYSE:1:GROUPC_B_calc.INPB",16777215,1,"BSOC:SYSE:1:GROUPC_B_calc.INPB") #! Field("BSOC:SYSE:1:GROUPC_B_calc.OUT",16777215,1,"BSOC:SYSE:1:GROUPC_B_calc.OUT") #! Link("BSOC:SYSE:1:GROUPC_B_calc.OUT","BSOC:SYSE:1:GROUPC_B.VAL") #! Record("BSOC:SYSE:1:GROUPC_B",500,20,0,0,"BSOC:SYSE:1:GROUPC_B") #! Field("BSOC:SYSE:1:GROUPC_B.VAL",16777215,1,"BSOC:SYSE:1:GROUPC_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi14") { field(DESC, "Port 30BSY_RDB bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:UND0:1:SECURE_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:UND0:1:SECURE_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:UND0:1:SECURE_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:UND0:1:SECURE_INP_B") { field(DESC, "LCLS_Secure_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb14",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb14") #! Field("PLC:BSY0:PP10:30BSY_RDBb14.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb14.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb14.FLNK","PPS:UND0:1:SECURE_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb14.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb14.VAL") #! Record("PPS:UND0:1:SECURE_INP_B_calc",260,18,0,1,"PPS:UND0:1:SECURE_INP_B_calc") #! Field("PPS:UND0:1:SECURE_INP_B_calc.INPA",16777215,0,"PPS:UND0:1:SECURE_INP_B_calc.INPA") #! Link("PPS:UND0:1:SECURE_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb14.VAL") #! Field("PPS:UND0:1:SECURE_INP_B_calc.INPB",16777215,1,"PPS:UND0:1:SECURE_INP_B_calc.INPB") #! Field("PPS:UND0:1:SECURE_INP_B_calc.OUT",16777215,1,"PPS:UND0:1:SECURE_INP_B_calc.OUT") #! Link("PPS:UND0:1:SECURE_INP_B_calc.OUT","PPS:UND0:1:SECURE_INP_B.VAL") #! Record("PPS:UND0:1:SECURE_INP_B",500,20,0,0,"PPS:UND0:1:SECURE_INP_B") #! Field("PPS:UND0:1:SECURE_INP_B.VAL",16777215,1,"PPS:UND0:1:SECURE_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi13") { field(DESC, "Port 30BSY_RDB bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 13, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_B") { field(DESC, "Local_Beam_Enable_Keysw_B") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb13",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb13") #! Field("PLC:BSY0:PP10:30BSY_RDBb13.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb13.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb13.FLNK","PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb13.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb13.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb13.VAL") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B_calc.OUT","PPS:SYSE:1:30BSY:LOCAL_ENABLE_B.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B",500,20,0,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_B") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi12") { field(DESC, "Port 30BSY_RDB bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 12, 1, 1)") field(ZNAM, "Not_Lowered") field(ONAM, "Lowered") field(FLNK, "PPS:LTU0:1:BCS_TRP_LOW_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LTU0:1:BCS_TRP_LOW_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LTU0:1:BCS_TRP_LOW_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LTU0:1:BCS_TRP_LOW_B") { field(DESC, "BCS_BTH_Trips_Low_Inp_B") field(ZNAM, "Not_Lowered") field(ONAM, "Lowered") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb12",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb12") #! Field("PLC:BSY0:PP10:30BSY_RDBb12.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb12.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb12.FLNK","PPS:LTU0:1:BCS_TRP_LOW_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb12.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb12.VAL") #! Record("PPS:LTU0:1:BCS_TRP_LOW_B_calc",260,18,0,1,"PPS:LTU0:1:BCS_TRP_LOW_B_calc") #! Field("PPS:LTU0:1:BCS_TRP_LOW_B_calc.INPA",16777215,0,"PPS:LTU0:1:BCS_TRP_LOW_B_calc.INPA") #! Link("PPS:LTU0:1:BCS_TRP_LOW_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb12.VAL") #! Field("PPS:LTU0:1:BCS_TRP_LOW_B_calc.INPB",16777215,1,"PPS:LTU0:1:BCS_TRP_LOW_B_calc.INPB") #! Field("PPS:LTU0:1:BCS_TRP_LOW_B_calc.OUT",16777215,1,"PPS:LTU0:1:BCS_TRP_LOW_B_calc.OUT") #! Link("PPS:LTU0:1:BCS_TRP_LOW_B_calc.OUT","PPS:LTU0:1:BCS_TRP_LOW_B.VAL") #! Record("PPS:LTU0:1:BCS_TRP_LOW_B",500,20,0,0,"PPS:LTU0:1:BCS_TRP_LOW_B") #! Field("PPS:LTU0:1:BCS_TRP_LOW_B.VAL",16777215,1,"PPS:LTU0:1:BCS_TRP_LOW_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi10") { field(DESC, "Port 30BSY_RDB bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 10, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:ACR_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:ACR_ENABLE_B") { field(DESC, "ACR_Beam_Enable_Keysw_B") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb10",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb10") #! Field("PLC:BSY0:PP10:30BSY_RDBb10.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb10.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb10.FLNK","PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb10.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb10.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb10.VAL") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_B_calc.OUT","PPS:SYSE:1:30BSY:ACR_ENABLE_B.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_B",500,20,0,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_B") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi9") { field(DESC, "Port 30BSY_RDB bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 9, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI28:1:HXR:KICKSEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICKSEP_OFF_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICKSEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICKSEP_OFF_B") { field(DESC, "HXR_KickSept_Off_Inp_B") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb9",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb9") #! Field("PLC:BSY0:PP10:30BSY_RDBb9.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb9.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb9.FLNK","PPS:LI28:1:HXR:KICKSEP_OFF_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb9.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb9.VAL") #! Record("PPS:LI28:1:HXR:KICKSEP_OFF_B_calc",260,18,0,1,"PPS:LI28:1:HXR:KICKSEP_OFF_B_calc") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.INPA") #! Link("PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb9.VAL") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.INPB") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.OUT") #! Link("PPS:LI28:1:HXR:KICKSEP_OFF_B_calc.OUT","PPS:LI28:1:HXR:KICKSEP_OFF_B.VAL") #! Record("PPS:LI28:1:HXR:KICKSEP_OFF_B",500,20,0,0,"PPS:LI28:1:HXR:KICKSEP_OFF_B") #! Field("PPS:LI28:1:HXR:KICKSEP_OFF_B.VAL",16777215,1,"PPS:LI28:1:HXR:KICKSEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi8") { field(DESC, "Port 30BSY_RDB bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 8, 1, 1)") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(FLNK, "PPS:LI28:1:HXR:KICK_COND_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICK_COND_OK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICK_COND_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICK_COND_OK_B") { field(DESC, "HXR_Kick_OK_B") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb8",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb8") #! Field("PLC:BSY0:PP10:30BSY_RDBb8.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb8.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb8.FLNK","PPS:LI28:1:HXR:KICK_COND_OK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb8.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb8.VAL") #! Record("PPS:LI28:1:HXR:KICK_COND_OK_B_calc",260,18,0,1,"PPS:LI28:1:HXR:KICK_COND_OK_B_calc") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_B_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICK_COND_OK_B_calc.INPA") #! Link("PPS:LI28:1:HXR:KICK_COND_OK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb8.VAL") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_B_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICK_COND_OK_B_calc.INPB") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_B_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICK_COND_OK_B_calc.OUT") #! Link("PPS:LI28:1:HXR:KICK_COND_OK_B_calc.OUT","PPS:LI28:1:HXR:KICK_COND_OK_B.VAL") #! Record("PPS:LI28:1:HXR:KICK_COND_OK_B",500,20,0,0,"PPS:LI28:1:HXR:KICK_COND_OK_B") #! Field("PPS:LI28:1:HXR:KICK_COND_OK_B.VAL",16777215,1,"PPS:LI28:1:HXR:KICK_COND_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi23") { field(DESC, "Port 30BSY_RDB bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 23, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI30:1:SXR:KICKSEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SXR:KICKSEP_OFF_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SXR:KICKSEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SXR:KICKSEP_OFF_B") { field(DESC, "SXR_KickSept_Off_Inp_B") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb23",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb23") #! Field("PLC:BSY0:PP10:30BSY_RDBb23.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb23.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb23.FLNK","PPS:LI30:1:SXR:KICKSEP_OFF_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb23.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb23.VAL") #! Record("PPS:LI30:1:SXR:KICKSEP_OFF_B_calc",260,18,0,1,"PPS:LI30:1:SXR:KICKSEP_OFF_B_calc") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.INPA",16777215,0,"PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.INPA") #! Link("PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb23.VAL") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.INPB",16777215,1,"PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.INPB") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.OUT",16777215,1,"PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.OUT") #! Link("PPS:LI30:1:SXR:KICKSEP_OFF_B_calc.OUT","PPS:LI30:1:SXR:KICKSEP_OFF_B.VAL") #! Record("PPS:LI30:1:SXR:KICKSEP_OFF_B",500,20,0,0,"PPS:LI30:1:SXR:KICKSEP_OFF_B") #! Field("PPS:LI30:1:SXR:KICKSEP_OFF_B.VAL",16777215,1,"PPS:LI30:1:SXR:KICKSEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi22") { field(DESC, "Port 30BSY_RDB bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 22, 1, 1)") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(FLNK, "PPS:LI30:1:SXR:KICK_COND_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SXR:KICK_COND_OK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SXR:KICK_COND_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SXR:KICK_COND_OK_B") { field(DESC, "SXR_Kick_OK_B") field(ZNAM, "NOT_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb22",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb22") #! Field("PLC:BSY0:PP10:30BSY_RDBb22.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb22.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb22.FLNK","PPS:LI30:1:SXR:KICK_COND_OK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb22.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb22.VAL") #! Record("PPS:LI30:1:SXR:KICK_COND_OK_B_calc",260,18,0,1,"PPS:LI30:1:SXR:KICK_COND_OK_B_calc") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_B_calc.INPA",16777215,0,"PPS:LI30:1:SXR:KICK_COND_OK_B_calc.INPA") #! Link("PPS:LI30:1:SXR:KICK_COND_OK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb22.VAL") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_B_calc.INPB",16777215,1,"PPS:LI30:1:SXR:KICK_COND_OK_B_calc.INPB") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_B_calc.OUT",16777215,1,"PPS:LI30:1:SXR:KICK_COND_OK_B_calc.OUT") #! Link("PPS:LI30:1:SXR:KICK_COND_OK_B_calc.OUT","PPS:LI30:1:SXR:KICK_COND_OK_B.VAL") #! Record("PPS:LI30:1:SXR:KICK_COND_OK_B",500,20,0,0,"PPS:LI30:1:SXR:KICK_COND_OK_B") #! Field("PPS:LI30:1:SXR:KICK_COND_OK_B.VAL",16777215,1,"PPS:LI30:1:SXR:KICK_COND_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi21") { field(DESC, "Port 30BSY_RDB bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 21, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:1:30BSY:STD2_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:30BSY:STD2_IN_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:30BSY:STD2_IN_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:30BSY:STD2_IN_B") { field(DESC, "STD2_Set_In_30BSY_Inp_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb21",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb21") #! Field("PLC:BSY0:PP10:30BSY_RDBb21.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb21.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb21.FLNK","STPR:BSYH:1:30BSY:STD2_IN_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb21.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb21.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_IN_B_calc",260,18,0,1,"STPR:BSYH:1:30BSY:STD2_IN_B_calc") #! Field("STPR:BSYH:1:30BSY:STD2_IN_B_calc.INPA",16777215,0,"STPR:BSYH:1:30BSY:STD2_IN_B_calc.INPA") #! Link("STPR:BSYH:1:30BSY:STD2_IN_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb21.VAL") #! Field("STPR:BSYH:1:30BSY:STD2_IN_B_calc.INPB",16777215,1,"STPR:BSYH:1:30BSY:STD2_IN_B_calc.INPB") #! Field("STPR:BSYH:1:30BSY:STD2_IN_B_calc.OUT",16777215,1,"STPR:BSYH:1:30BSY:STD2_IN_B_calc.OUT") #! Link("STPR:BSYH:1:30BSY:STD2_IN_B_calc.OUT","STPR:BSYH:1:30BSY:STD2_IN_B.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_IN_B",500,20,0,0,"STPR:BSYH:1:30BSY:STD2_IN_B") #! Field("STPR:BSYH:1:30BSY:STD2_IN_B.VAL",16777215,1,"STPR:BSYH:1:30BSY:STD2_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi20") { field(DESC, "Port 30BSY_RDB bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 20, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:1:30BSY:STD2_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:30BSY:STD2_OUT_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:30BSY:STD2_OUT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:30BSY:STD2_OUT_B") { field(DESC, "STD2_Set_Out_30BSY_Inp_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb20",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb20") #! Field("PLC:BSY0:PP10:30BSY_RDBb20.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb20.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb20.FLNK","STPR:BSYH:1:30BSY:STD2_OUT_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb20.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb20.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_OUT_B_calc",260,18,0,1,"STPR:BSYH:1:30BSY:STD2_OUT_B_calc") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_B_calc.INPA",16777215,0,"STPR:BSYH:1:30BSY:STD2_OUT_B_calc.INPA") #! Link("STPR:BSYH:1:30BSY:STD2_OUT_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb20.VAL") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_B_calc.INPB",16777215,1,"STPR:BSYH:1:30BSY:STD2_OUT_B_calc.INPB") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_B_calc.OUT",16777215,1,"STPR:BSYH:1:30BSY:STD2_OUT_B_calc.OUT") #! Link("STPR:BSYH:1:30BSY:STD2_OUT_B_calc.OUT","STPR:BSYH:1:30BSY:STD2_OUT_B.VAL") #! Record("STPR:BSYH:1:30BSY:STD2_OUT_B",500,20,0,0,"STPR:BSYH:1:30BSY:STD2_OUT_B") #! Field("STPR:BSYH:1:30BSY:STD2_OUT_B.VAL",16777215,1,"STPR:BSYH:1:30BSY:STD2_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi19") { field(DESC, "Port 30BSY_RDB bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 19, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYS:1:ST34_IN_SUM_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:1:ST34_IN_SUM_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi19 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:1:ST34_IN_SUM_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:1:ST34_IN_SUM_B") { field(DESC, "ST34_Set_In_Inp_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb19",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb19") #! Field("PLC:BSY0:PP10:30BSY_RDBb19.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb19.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb19.FLNK","STPR:BSYS:1:ST34_IN_SUM_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb19.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb19.VAL") #! Record("STPR:BSYS:1:ST34_IN_SUM_B_calc",260,18,0,1,"STPR:BSYS:1:ST34_IN_SUM_B_calc") #! Field("STPR:BSYS:1:ST34_IN_SUM_B_calc.INPA",16777215,0,"STPR:BSYS:1:ST34_IN_SUM_B_calc.INPA") #! Link("STPR:BSYS:1:ST34_IN_SUM_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb19.VAL") #! Field("STPR:BSYS:1:ST34_IN_SUM_B_calc.INPB",16777215,1,"STPR:BSYS:1:ST34_IN_SUM_B_calc.INPB") #! Field("STPR:BSYS:1:ST34_IN_SUM_B_calc.OUT",16777215,1,"STPR:BSYS:1:ST34_IN_SUM_B_calc.OUT") #! Link("STPR:BSYS:1:ST34_IN_SUM_B_calc.OUT","STPR:BSYS:1:ST34_IN_SUM_B.VAL") #! Record("STPR:BSYS:1:ST34_IN_SUM_B",500,20,0,0,"STPR:BSYS:1:ST34_IN_SUM_B") #! Field("STPR:BSYS:1:ST34_IN_SUM_B.VAL",16777215,1,"STPR:BSYS:1:ST34_IN_SUM_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi18") { field(DESC, "Port 30BSY_RDB bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 18, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYS:1:ST34_OUT_SUM_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:1:ST34_OUT_SUM_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi18 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:1:ST34_OUT_SUM_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:1:ST34_OUT_SUM_B") { field(DESC, "ST34_Set_Out_Inp_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb18",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb18") #! Field("PLC:BSY0:PP10:30BSY_RDBb18.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb18.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb18.FLNK","STPR:BSYS:1:ST34_OUT_SUM_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb18.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb18.VAL") #! Record("STPR:BSYS:1:ST34_OUT_SUM_B_calc",260,18,0,1,"STPR:BSYS:1:ST34_OUT_SUM_B_calc") #! Field("STPR:BSYS:1:ST34_OUT_SUM_B_calc.INPA",16777215,0,"STPR:BSYS:1:ST34_OUT_SUM_B_calc.INPA") #! Link("STPR:BSYS:1:ST34_OUT_SUM_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb18.VAL") #! Field("STPR:BSYS:1:ST34_OUT_SUM_B_calc.INPB",16777215,1,"STPR:BSYS:1:ST34_OUT_SUM_B_calc.INPB") #! Field("STPR:BSYS:1:ST34_OUT_SUM_B_calc.OUT",16777215,1,"STPR:BSYS:1:ST34_OUT_SUM_B_calc.OUT") #! Link("STPR:BSYS:1:ST34_OUT_SUM_B_calc.OUT","STPR:BSYS:1:ST34_OUT_SUM_B.VAL") #! Record("STPR:BSYS:1:ST34_OUT_SUM_B",500,20,0,0,"STPR:BSYS:1:ST34_OUT_SUM_B") #! Field("STPR:BSYS:1:ST34_OUT_SUM_B.VAL",16777215,1,"STPR:BSYS:1:ST34_OUT_SUM_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi17") { field(DESC, "Port 30BSY_RDB bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 17, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:CLTS:585:IN_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:IN_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi17 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:IN_INP_B PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:IN_INP_B") { field(DESC, "STCLTS_In_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb17",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb17") #! Field("PLC:BSY0:PP10:30BSY_RDBb17.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb17.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb17.FLNK","STPR:CLTS:585:IN_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb17.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb17.VAL") #! Record("STPR:CLTS:585:IN_INP_B_calc",260,18,0,1,"STPR:CLTS:585:IN_INP_B_calc") #! Field("STPR:CLTS:585:IN_INP_B_calc.INPA",16777215,0,"STPR:CLTS:585:IN_INP_B_calc.INPA") #! Link("STPR:CLTS:585:IN_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb17.VAL") #! Field("STPR:CLTS:585:IN_INP_B_calc.INPB",16777215,1,"STPR:CLTS:585:IN_INP_B_calc.INPB") #! Field("STPR:CLTS:585:IN_INP_B_calc.OUT",16777215,1,"STPR:CLTS:585:IN_INP_B_calc.OUT") #! Link("STPR:CLTS:585:IN_INP_B_calc.OUT","STPR:CLTS:585:IN_INP_B.VAL") #! Record("STPR:CLTS:585:IN_INP_B",500,20,0,0,"STPR:CLTS:585:IN_INP_B") #! Field("STPR:CLTS:585:IN_INP_B.VAL",16777215,1,"STPR:CLTS:585:IN_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi16") { field(DESC, "Port 30BSY_RDB bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 16, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:CLTS:585:OUT_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:OUT_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi16 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:OUT_INP_B PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:OUT_INP_B") { field(DESC, "STCLTS_Out_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb16",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb16") #! Field("PLC:BSY0:PP10:30BSY_RDBb16.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb16.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb16.FLNK","STPR:CLTS:585:OUT_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb16.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb16.VAL") #! Record("STPR:CLTS:585:OUT_INP_B_calc",260,18,0,1,"STPR:CLTS:585:OUT_INP_B_calc") #! Field("STPR:CLTS:585:OUT_INP_B_calc.INPA",16777215,0,"STPR:CLTS:585:OUT_INP_B_calc.INPA") #! Link("STPR:CLTS:585:OUT_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb16.VAL") #! Field("STPR:CLTS:585:OUT_INP_B_calc.INPB",16777215,1,"STPR:CLTS:585:OUT_INP_B_calc.INPB") #! Field("STPR:CLTS:585:OUT_INP_B_calc.OUT",16777215,1,"STPR:CLTS:585:OUT_INP_B_calc.OUT") #! Link("STPR:CLTS:585:OUT_INP_B_calc.OUT","STPR:CLTS:585:OUT_INP_B.VAL") #! Record("STPR:CLTS:585:OUT_INP_B",500,20,0,0,"STPR:CLTS:585:OUT_INP_B") #! Field("STPR:CLTS:585:OUT_INP_B.VAL",16777215,1,"STPR:CLTS:585:OUT_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi95") { field(DESC, "Port 30BSY_RDB bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 95, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:1:KICK_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:KICK_OFF_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi95 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:KICK_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:KICK_OFF_B") { field(DESC, "CLTS_Kicker_OFF_B") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb95",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb95") #! Field("PLC:BSY0:PP10:30BSY_RDBb95.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb95.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb95.FLNK","PPS:CLTS:1:KICK_OFF_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb95.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb95.VAL") #! Record("PPS:CLTS:1:KICK_OFF_B_calc",260,18,0,1,"PPS:CLTS:1:KICK_OFF_B_calc") #! Field("PPS:CLTS:1:KICK_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:1:KICK_OFF_B_calc.INPA") #! Link("PPS:CLTS:1:KICK_OFF_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb95.VAL") #! Field("PPS:CLTS:1:KICK_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:1:KICK_OFF_B_calc.INPB") #! Field("PPS:CLTS:1:KICK_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:1:KICK_OFF_B_calc.OUT") #! Link("PPS:CLTS:1:KICK_OFF_B_calc.OUT","PPS:CLTS:1:KICK_OFF_B.VAL") #! Record("PPS:CLTS:1:KICK_OFF_B",500,20,0,0,"PPS:CLTS:1:KICK_OFF_B") #! Field("PPS:CLTS:1:KICK_OFF_B.VAL",16777215,1,"PPS:CLTS:1:KICK_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi94") { field(DESC, "Port 30BSY_RDB bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 94, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:1:DCBEND_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:DCBEND_OFF_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi94 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:DCBEND_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:DCBEND_OFF_B") { field(DESC, "CLTS_DC_Bend_OFF_B") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb94",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb94") #! Field("PLC:BSY0:PP10:30BSY_RDBb94.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb94.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb94.FLNK","PPS:CLTS:1:DCBEND_OFF_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb94.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb94.VAL") #! Record("PPS:CLTS:1:DCBEND_OFF_B_calc",260,18,0,1,"PPS:CLTS:1:DCBEND_OFF_B_calc") #! Field("PPS:CLTS:1:DCBEND_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:1:DCBEND_OFF_B_calc.INPA") #! Link("PPS:CLTS:1:DCBEND_OFF_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb94.VAL") #! Field("PPS:CLTS:1:DCBEND_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:1:DCBEND_OFF_B_calc.INPB") #! Field("PPS:CLTS:1:DCBEND_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:1:DCBEND_OFF_B_calc.OUT") #! Link("PPS:CLTS:1:DCBEND_OFF_B_calc.OUT","PPS:CLTS:1:DCBEND_OFF_B.VAL") #! Record("PPS:CLTS:1:DCBEND_OFF_B",500,20,0,0,"PPS:CLTS:1:DCBEND_OFF_B") #! Field("PPS:CLTS:1:DCBEND_OFF_B.VAL",16777215,1,"PPS:CLTS:1:DCBEND_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi92") { field(DESC, "Port 30BSY_RDB bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 92, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:BSYS:1:MERGE_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:MERGE_OFF_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi92 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:MERGE_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:MERGE_OFF_B") { field(DESC, "SXR_Merge_Dipole_OFF_B") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb92",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb92") #! Field("PLC:BSY0:PP10:30BSY_RDBb92.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb92.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb92.FLNK","PPS:BSYS:1:MERGE_OFF_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb92.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb92.VAL") #! Record("PPS:BSYS:1:MERGE_OFF_B_calc",260,18,0,1,"PPS:BSYS:1:MERGE_OFF_B_calc") #! Field("PPS:BSYS:1:MERGE_OFF_B_calc.INPA",16777215,0,"PPS:BSYS:1:MERGE_OFF_B_calc.INPA") #! Link("PPS:BSYS:1:MERGE_OFF_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb92.VAL") #! Field("PPS:BSYS:1:MERGE_OFF_B_calc.INPB",16777215,1,"PPS:BSYS:1:MERGE_OFF_B_calc.INPB") #! Field("PPS:BSYS:1:MERGE_OFF_B_calc.OUT",16777215,1,"PPS:BSYS:1:MERGE_OFF_B_calc.OUT") #! Link("PPS:BSYS:1:MERGE_OFF_B_calc.OUT","PPS:BSYS:1:MERGE_OFF_B.VAL") #! Record("PPS:BSYS:1:MERGE_OFF_B",500,20,0,0,"PPS:BSYS:1:MERGE_OFF_B") #! Field("PPS:BSYS:1:MERGE_OFF_B.VAL",16777215,1,"PPS:BSYS:1:MERGE_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi90") { field(DESC, "Port 30BSY_RDB bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 90, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:CLTS:1:DCBEND_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:DCBEND_ON_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:DCBEND_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:DCBEND_ON_B") { field(DESC, "CLTS_DC_Bend_On_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb90",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb90") #! Field("PLC:BSY0:PP10:30BSY_RDBb90.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb90.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb90.FLNK","PPS:CLTS:1:DCBEND_ON_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb90.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb90.VAL") #! Record("PPS:CLTS:1:DCBEND_ON_B_calc",260,18,0,1,"PPS:CLTS:1:DCBEND_ON_B_calc") #! Field("PPS:CLTS:1:DCBEND_ON_B_calc.INPA",16777215,0,"PPS:CLTS:1:DCBEND_ON_B_calc.INPA") #! Link("PPS:CLTS:1:DCBEND_ON_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb90.VAL") #! Field("PPS:CLTS:1:DCBEND_ON_B_calc.INPB",16777215,1,"PPS:CLTS:1:DCBEND_ON_B_calc.INPB") #! Field("PPS:CLTS:1:DCBEND_ON_B_calc.OUT",16777215,1,"PPS:CLTS:1:DCBEND_ON_B_calc.OUT") #! Link("PPS:CLTS:1:DCBEND_ON_B_calc.OUT","PPS:CLTS:1:DCBEND_ON_B.VAL") #! Record("PPS:CLTS:1:DCBEND_ON_B",500,20,0,0,"PPS:CLTS:1:DCBEND_ON_B") #! Field("PPS:CLTS:1:DCBEND_ON_B.VAL",16777215,1,"PPS:CLTS:1:DCBEND_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi89") { field(DESC, "Port 30BSY_RDB bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 89, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:CLTS:1:SEP_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:SEP_ON_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:SEP_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:SEP_ON_B") { field(DESC, "CLTS_Septum_On_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb89",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb89") #! Field("PLC:BSY0:PP10:30BSY_RDBb89.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb89.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb89.FLNK","PPS:CLTS:1:SEP_ON_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb89.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb89.VAL") #! Record("PPS:CLTS:1:SEP_ON_B_calc",260,18,0,1,"PPS:CLTS:1:SEP_ON_B_calc") #! Field("PPS:CLTS:1:SEP_ON_B_calc.INPA",16777215,0,"PPS:CLTS:1:SEP_ON_B_calc.INPA") #! Link("PPS:CLTS:1:SEP_ON_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb89.VAL") #! Field("PPS:CLTS:1:SEP_ON_B_calc.INPB",16777215,1,"PPS:CLTS:1:SEP_ON_B_calc.INPB") #! Field("PPS:CLTS:1:SEP_ON_B_calc.OUT",16777215,1,"PPS:CLTS:1:SEP_ON_B_calc.OUT") #! Link("PPS:CLTS:1:SEP_ON_B_calc.OUT","PPS:CLTS:1:SEP_ON_B.VAL") #! Record("PPS:CLTS:1:SEP_ON_B",500,20,0,0,"PPS:CLTS:1:SEP_ON_B") #! Field("PPS:CLTS:1:SEP_ON_B.VAL",16777215,1,"PPS:CLTS:1:SEP_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi88") { field(DESC, "Port 30BSY_RDB bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 88, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:MERGE_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:MERGE_ON_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:MERGE_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:MERGE_ON_B") { field(DESC, "SXR_Merge_Dipole_On_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb88",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb88") #! Field("PLC:BSY0:PP10:30BSY_RDBb88.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb88.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb88.FLNK","PPS:BSYS:1:MERGE_ON_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb88.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb88.VAL") #! Record("PPS:BSYS:1:MERGE_ON_B_calc",260,18,0,1,"PPS:BSYS:1:MERGE_ON_B_calc") #! Field("PPS:BSYS:1:MERGE_ON_B_calc.INPA",16777215,0,"PPS:BSYS:1:MERGE_ON_B_calc.INPA") #! Link("PPS:BSYS:1:MERGE_ON_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb88.VAL") #! Field("PPS:BSYS:1:MERGE_ON_B_calc.INPB",16777215,1,"PPS:BSYS:1:MERGE_ON_B_calc.INPB") #! Field("PPS:BSYS:1:MERGE_ON_B_calc.OUT",16777215,1,"PPS:BSYS:1:MERGE_ON_B_calc.OUT") #! Link("PPS:BSYS:1:MERGE_ON_B_calc.OUT","PPS:BSYS:1:MERGE_ON_B.VAL") #! Record("PPS:BSYS:1:MERGE_ON_B",500,20,0,0,"PPS:BSYS:1:MERGE_ON_B") #! Field("PPS:BSYS:1:MERGE_ON_B.VAL",16777215,1,"PPS:BSYS:1:MERGE_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi103") { field(DESC, "Port 30BSY_RDB bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 103, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:30BSY:INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:INTLK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:INTLK_B") { field(DESC, "30-BSY interlock A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb103",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb103") #! Field("PLC:BSY0:PP10:30BSY_RDBb103.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb103.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb103.FLNK","PPS:SYSE:1:30BSY:INTLK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb103.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb103.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:INTLK_B_calc") #! Field("PPS:SYSE:1:30BSY:INTLK_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:INTLK_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:INTLK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb103.VAL") #! Field("PPS:SYSE:1:30BSY:INTLK_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:INTLK_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:INTLK_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:INTLK_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:INTLK_B_calc.OUT","PPS:SYSE:1:30BSY:INTLK_B.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_B",500,20,0,0,"PPS:SYSE:1:30BSY:INTLK_B") #! Field("PPS:SYSE:1:30BSY:INTLK_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi102") { field(DESC, "Port 30BSY_RDB bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 102, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:CU:INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:INTLK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:INTLK_B") { field(DESC, "Cu beam interlock A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb102",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb102") #! Field("PLC:BSY0:PP10:30BSY_RDBb102.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb102.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb102.FLNK","PPS:SYSE:1:CU:INTLK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb102.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb102.VAL") #! Record("PPS:SYSE:1:CU:INTLK_B_calc",260,18,0,1,"PPS:SYSE:1:CU:INTLK_B_calc") #! Field("PPS:SYSE:1:CU:INTLK_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:INTLK_B_calc.INPA") #! Link("PPS:SYSE:1:CU:INTLK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb102.VAL") #! Field("PPS:SYSE:1:CU:INTLK_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:INTLK_B_calc.INPB") #! Field("PPS:SYSE:1:CU:INTLK_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:INTLK_B_calc.OUT") #! Link("PPS:SYSE:1:CU:INTLK_B_calc.OUT","PPS:SYSE:1:CU:INTLK_B.VAL") #! Record("PPS:SYSE:1:CU:INTLK_B",500,20,0,0,"PPS:SYSE:1:CU:INTLK_B") #! Field("PPS:SYSE:1:CU:INTLK_B.VAL",16777215,1,"PPS:SYSE:1:CU:INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi101") { field(DESC, "Port 30BSY_RDB bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 101, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:SC:INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SC:INTLK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SC:INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SC:INTLK_B") { field(DESC, "SC beam interlock A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb101",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb101") #! Field("PLC:BSY0:PP10:30BSY_RDBb101.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb101.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb101.FLNK","PPS:SYSE:1:SC:INTLK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb101.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb101.VAL") #! Record("PPS:SYSE:1:SC:INTLK_B_calc",260,18,0,1,"PPS:SYSE:1:SC:INTLK_B_calc") #! Field("PPS:SYSE:1:SC:INTLK_B_calc.INPA",16777215,0,"PPS:SYSE:1:SC:INTLK_B_calc.INPA") #! Link("PPS:SYSE:1:SC:INTLK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb101.VAL") #! Field("PPS:SYSE:1:SC:INTLK_B_calc.INPB",16777215,1,"PPS:SYSE:1:SC:INTLK_B_calc.INPB") #! Field("PPS:SYSE:1:SC:INTLK_B_calc.OUT",16777215,1,"PPS:SYSE:1:SC:INTLK_B_calc.OUT") #! Link("PPS:SYSE:1:SC:INTLK_B_calc.OUT","PPS:SYSE:1:SC:INTLK_B.VAL") #! Record("PPS:SYSE:1:SC:INTLK_B",500,20,0,0,"PPS:SYSE:1:SC:INTLK_B") #! Field("PPS:SYSE:1:SC:INTLK_B.VAL",16777215,1,"PPS:SYSE:1:SC:INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi100") { field(DESC, "Port 30BSY_RDB bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 100, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:BTH_ACCESS_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BTH_ACCESS_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BTH_ACCESS_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BTH_ACCESS_B") { field(DESC, "BTH Access cond. A (spare)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb100",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb100") #! Field("PLC:BSY0:PP10:30BSY_RDBb100.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb100.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb100.FLNK","PPS:SYSE:1:BTH_ACCESS_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb100.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb100.VAL") #! Record("PPS:SYSE:1:BTH_ACCESS_B_calc",260,18,0,1,"PPS:SYSE:1:BTH_ACCESS_B_calc") #! Field("PPS:SYSE:1:BTH_ACCESS_B_calc.INPA",16777215,0,"PPS:SYSE:1:BTH_ACCESS_B_calc.INPA") #! Link("PPS:SYSE:1:BTH_ACCESS_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb100.VAL") #! Field("PPS:SYSE:1:BTH_ACCESS_B_calc.INPB",16777215,1,"PPS:SYSE:1:BTH_ACCESS_B_calc.INPB") #! Field("PPS:SYSE:1:BTH_ACCESS_B_calc.OUT",16777215,1,"PPS:SYSE:1:BTH_ACCESS_B_calc.OUT") #! Link("PPS:SYSE:1:BTH_ACCESS_B_calc.OUT","PPS:SYSE:1:BTH_ACCESS_B.VAL") #! Record("PPS:SYSE:1:BTH_ACCESS_B",500,20,0,0,"PPS:SYSE:1:BTH_ACCESS_B") #! Field("PPS:SYSE:1:BTH_ACCESS_B.VAL",16777215,1,"PPS:SYSE:1:BTH_ACCESS_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi99") { field(DESC, "Port 30BSY_RDB bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 99, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi99 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:CROSS_CHECK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:CROSS_CHECK_B") { field(DESC, "Cross_Check_Keysw_in_Normal_B") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb99",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb99") #! Field("PLC:BSY0:PP10:30BSY_RDBb99.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb99.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb99.FLNK","PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb99.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb99.VAL") #! Record("PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb99.VAL") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:CROSS_CHECK_B_calc.OUT","PPS:SYSE:1:30BSY:CROSS_CHECK_B.VAL") #! Record("PPS:SYSE:1:30BSY:CROSS_CHECK_B",500,20,0,0,"PPS:SYSE:1:30BSY:CROSS_CHECK_B") #! Field("PPS:SYSE:1:30BSY:CROSS_CHECK_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:CROSS_CHECK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi98") { field(DESC, "Port 30BSY_RDB bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_INP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi98 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_INP_B") { field(DESC, "Heartbeat IN (other chn.) B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb98",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb98") #! Field("PLC:BSY0:PP10:30BSY_RDBb98.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb98.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb98.FLNK","PPS:SYSE:1:30BSY:HRTBT_INP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb98.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb98.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_INP_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_INP_B_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb98.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_INP_B_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_INP_B.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_INP_B",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_INP_B") #! Field("PPS:SYSE:1:30BSY:HRTBT_INP_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi97") { field(DESC, "Port 30BSY_RDB bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 97, 1, 1)") field(ZNAM, "NOT_READY") field(ONAM, "READY") field(FLNK, "PPS:SYSE:1:BEAM_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BEAM_ON_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BEAM_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BEAM_ON_B") { field(DESC, "Linac E. Global in Ready for Beam") field(ZNAM, "NOT_READY") field(ONAM, "READY") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb97",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb97") #! Field("PLC:BSY0:PP10:30BSY_RDBb97.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb97.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb97.FLNK","PPS:SYSE:1:BEAM_ON_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb97.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb97.VAL") #! Record("PPS:SYSE:1:BEAM_ON_B_calc",260,18,0,1,"PPS:SYSE:1:BEAM_ON_B_calc") #! Field("PPS:SYSE:1:BEAM_ON_B_calc.INPA",16777215,0,"PPS:SYSE:1:BEAM_ON_B_calc.INPA") #! Link("PPS:SYSE:1:BEAM_ON_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb97.VAL") #! Field("PPS:SYSE:1:BEAM_ON_B_calc.INPB",16777215,1,"PPS:SYSE:1:BEAM_ON_B_calc.INPB") #! Field("PPS:SYSE:1:BEAM_ON_B_calc.OUT",16777215,1,"PPS:SYSE:1:BEAM_ON_B_calc.OUT") #! Link("PPS:SYSE:1:BEAM_ON_B_calc.OUT","PPS:SYSE:1:BEAM_ON_B.VAL") #! Record("PPS:SYSE:1:BEAM_ON_B",500,20,0,0,"PPS:SYSE:1:BEAM_ON_B") #! Field("PPS:SYSE:1:BEAM_ON_B.VAL",16777215,1,"PPS:SYSE:1:BEAM_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi111") { field(DESC, "Port 30BSY_RDB bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 111, 1, 1)") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(FLNK, "PPS:SYSE:1:HW_RESET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:HW_RESET_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:HW_RESET_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:HW_RESET_B") { field(DESC, "HW Reset B") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb111",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb111") #! Field("PLC:BSY0:PP10:30BSY_RDBb111.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb111.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb111.FLNK","PPS:SYSE:1:HW_RESET_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb111.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb111.VAL") #! Record("PPS:SYSE:1:HW_RESET_B_calc",260,18,0,1,"PPS:SYSE:1:HW_RESET_B_calc") #! Field("PPS:SYSE:1:HW_RESET_B_calc.INPA",16777215,0,"PPS:SYSE:1:HW_RESET_B_calc.INPA") #! Link("PPS:SYSE:1:HW_RESET_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb111.VAL") #! Field("PPS:SYSE:1:HW_RESET_B_calc.INPB",16777215,1,"PPS:SYSE:1:HW_RESET_B_calc.INPB") #! Field("PPS:SYSE:1:HW_RESET_B_calc.OUT",16777215,1,"PPS:SYSE:1:HW_RESET_B_calc.OUT") #! Link("PPS:SYSE:1:HW_RESET_B_calc.OUT","PPS:SYSE:1:HW_RESET_B.VAL") #! Record("PPS:SYSE:1:HW_RESET_B",500,20,0,0,"PPS:SYSE:1:HW_RESET_B") #! Field("PPS:SYSE:1:HW_RESET_B.VAL",16777215,1,"PPS:SYSE:1:HW_RESET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi110") { field(DESC, "Port 30BSY_RDB bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 110, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:SYSE:1:RSY_SECURE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:RSY_SECURE_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:RSY_SECURE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:RSY_SECURE_B") { field(DESC, "RSY Secure B") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb110",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb110") #! Field("PLC:BSY0:PP10:30BSY_RDBb110.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb110.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb110.FLNK","PPS:SYSE:1:RSY_SECURE_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb110.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb110.VAL") #! Record("PPS:SYSE:1:RSY_SECURE_B_calc",260,18,0,1,"PPS:SYSE:1:RSY_SECURE_B_calc") #! Field("PPS:SYSE:1:RSY_SECURE_B_calc.INPA",16777215,0,"PPS:SYSE:1:RSY_SECURE_B_calc.INPA") #! Link("PPS:SYSE:1:RSY_SECURE_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb110.VAL") #! Field("PPS:SYSE:1:RSY_SECURE_B_calc.INPB",16777215,1,"PPS:SYSE:1:RSY_SECURE_B_calc.INPB") #! Field("PPS:SYSE:1:RSY_SECURE_B_calc.OUT",16777215,1,"PPS:SYSE:1:RSY_SECURE_B_calc.OUT") #! Link("PPS:SYSE:1:RSY_SECURE_B_calc.OUT","PPS:SYSE:1:RSY_SECURE_B.VAL") #! Record("PPS:SYSE:1:RSY_SECURE_B",500,20,0,0,"PPS:SYSE:1:RSY_SECURE_B") #! Field("PPS:SYSE:1:RSY_SECURE_B.VAL",16777215,1,"PPS:SYSE:1:RSY_SECURE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi109") { field(DESC, "Port 30BSY_RDB bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 109, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:SPARE_4_i6_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SPARE_4_i6_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SPARE_4_i6_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SPARE_4_i6_B") { field(DESC, "Spare 4.i6 B") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb109",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb109") #! Field("PLC:BSY0:PP10:30BSY_RDBb109.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb109.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb109.FLNK","PPS:SYSE:1:SPARE_4_i6_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb109.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb109.VAL") #! Record("PPS:SYSE:1:SPARE_4_i6_B_calc",260,18,0,1,"PPS:SYSE:1:SPARE_4_i6_B_calc") #! Field("PPS:SYSE:1:SPARE_4_i6_B_calc.INPA",16777215,0,"PPS:SYSE:1:SPARE_4_i6_B_calc.INPA") #! Link("PPS:SYSE:1:SPARE_4_i6_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb109.VAL") #! Field("PPS:SYSE:1:SPARE_4_i6_B_calc.INPB",16777215,1,"PPS:SYSE:1:SPARE_4_i6_B_calc.INPB") #! Field("PPS:SYSE:1:SPARE_4_i6_B_calc.OUT",16777215,1,"PPS:SYSE:1:SPARE_4_i6_B_calc.OUT") #! Link("PPS:SYSE:1:SPARE_4_i6_B_calc.OUT","PPS:SYSE:1:SPARE_4_i6_B.VAL") #! Record("PPS:SYSE:1:SPARE_4_i6_B",500,20,0,0,"PPS:SYSE:1:SPARE_4_i6_B") #! Field("PPS:SYSE:1:SPARE_4_i6_B.VAL",16777215,1,"PPS:SYSE:1:SPARE_4_i6_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi108") { field(DESC, "Port 30BSY_RDB bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 108, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "PPS:SYSE:1:SPARE_4_i7_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SPARE_4_i7_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SPARE_4_i7_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SPARE_4_i7_B") { field(DESC, "Spare 4.i7 B") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb108",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb108") #! Field("PLC:BSY0:PP10:30BSY_RDBb108.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb108.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb108.FLNK","PPS:SYSE:1:SPARE_4_i7_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb108.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb108.VAL") #! Record("PPS:SYSE:1:SPARE_4_i7_B_calc",260,18,0,1,"PPS:SYSE:1:SPARE_4_i7_B_calc") #! Field("PPS:SYSE:1:SPARE_4_i7_B_calc.INPA",16777215,0,"PPS:SYSE:1:SPARE_4_i7_B_calc.INPA") #! Link("PPS:SYSE:1:SPARE_4_i7_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb108.VAL") #! Field("PPS:SYSE:1:SPARE_4_i7_B_calc.INPB",16777215,1,"PPS:SYSE:1:SPARE_4_i7_B_calc.INPB") #! Field("PPS:SYSE:1:SPARE_4_i7_B_calc.OUT",16777215,1,"PPS:SYSE:1:SPARE_4_i7_B_calc.OUT") #! Link("PPS:SYSE:1:SPARE_4_i7_B_calc.OUT","PPS:SYSE:1:SPARE_4_i7_B.VAL") #! Record("PPS:SYSE:1:SPARE_4_i7_B",500,20,0,0,"PPS:SYSE:1:SPARE_4_i7_B") #! Field("PPS:SYSE:1:SPARE_4_i7_B.VAL",16777215,1,"PPS:SYSE:1:SPARE_4_i7_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi107") { field(DESC, "Port 30BSY_RDB bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 107, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:SYSE:2:30BSY:SECURE_COM_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:2:30BSY:SECURE_COM_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:2:30BSY:SECURE_COM_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:2:30BSY:SECURE_COM_B") { field(DESC, "30-BSY Sec. Comp. (test mode)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb107",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb107") #! Field("PLC:BSY0:PP10:30BSY_RDBb107.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb107.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb107.FLNK","PPS:SYSE:2:30BSY:SECURE_COM_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb107.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb107.VAL") #! Record("PPS:SYSE:2:30BSY:SECURE_COM_B_calc",260,18,0,1,"PPS:SYSE:2:30BSY:SECURE_COM_B_calc") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_B_calc.INPA",16777215,0,"PPS:SYSE:2:30BSY:SECURE_COM_B_calc.INPA") #! Link("PPS:SYSE:2:30BSY:SECURE_COM_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb107.VAL") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_B_calc.INPB",16777215,1,"PPS:SYSE:2:30BSY:SECURE_COM_B_calc.INPB") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_B_calc.OUT",16777215,1,"PPS:SYSE:2:30BSY:SECURE_COM_B_calc.OUT") #! Link("PPS:SYSE:2:30BSY:SECURE_COM_B_calc.OUT","PPS:SYSE:2:30BSY:SECURE_COM_B.VAL") #! Record("PPS:SYSE:2:30BSY:SECURE_COM_B",500,20,0,0,"PPS:SYSE:2:30BSY:SECURE_COM_B") #! Field("PPS:SYSE:2:30BSY:SECURE_COM_B.VAL",16777215,1,"PPS:SYSE:2:30BSY:SECURE_COM_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi106") { field(DESC, "Port 30BSY_RDB bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 106, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:SYSE:3:30BSY:SECURE_COM_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:3:30BSY:SECURE_COM_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:3:30BSY:SECURE_COM_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:3:30BSY:SECURE_COM_B") { field(DESC, "30-BSY Sec. Comp. (other ch.)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb106",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb106") #! Field("PLC:BSY0:PP10:30BSY_RDBb106.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb106.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb106.FLNK","PPS:SYSE:3:30BSY:SECURE_COM_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb106.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb106.VAL") #! Record("PPS:SYSE:3:30BSY:SECURE_COM_B_calc",260,18,0,1,"PPS:SYSE:3:30BSY:SECURE_COM_B_calc") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_B_calc.INPA",16777215,0,"PPS:SYSE:3:30BSY:SECURE_COM_B_calc.INPA") #! Link("PPS:SYSE:3:30BSY:SECURE_COM_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb106.VAL") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_B_calc.INPB",16777215,1,"PPS:SYSE:3:30BSY:SECURE_COM_B_calc.INPB") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_B_calc.OUT",16777215,1,"PPS:SYSE:3:30BSY:SECURE_COM_B_calc.OUT") #! Link("PPS:SYSE:3:30BSY:SECURE_COM_B_calc.OUT","PPS:SYSE:3:30BSY:SECURE_COM_B.VAL") #! Record("PPS:SYSE:3:30BSY:SECURE_COM_B",500,20,0,0,"PPS:SYSE:3:30BSY:SECURE_COM_B") #! Field("PPS:SYSE:3:30BSY:SECURE_COM_B.VAL",16777215,1,"PPS:SYSE:3:30BSY:SECURE_COM_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi105") { field(DESC, "Port 30BSY_RDB bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 105, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HWALRMWARN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HWALRMWARN_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HWALRMWARN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HWALRMWARN_B") { field(DESC, "HW_Alarm_Warning_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb105",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb105") #! Field("PLC:BSY0:PP10:30BSY_RDBb105.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb105.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb105.FLNK","PPS:SYSE:1:30BSY:HWALRMWARN_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb105.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb105.VAL") #! Record("PPS:SYSE:1:30BSY:HWALRMWARN_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HWALRMWARN_B_calc") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb105.VAL") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HWALRMWARN_B_calc.OUT","PPS:SYSE:1:30BSY:HWALRMWARN_B.VAL") #! Record("PPS:SYSE:1:30BSY:HWALRMWARN_B",500,20,0,0,"PPS:SYSE:1:30BSY:HWALRMWARN_B") #! Field("PPS:SYSE:1:30BSY:HWALRMWARN_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:HWALRMWARN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi104") { field(DESC, "Port 30BSY_RDB bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 104, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_OUTP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_OUTP_B") { field(DESC, "PLC_Heartbeat_Output_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb104",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb104") #! Field("PLC:BSY0:PP10:30BSY_RDBb104.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb104.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb104.FLNK","PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb104.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb104.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb104.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_OUTP_B_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_OUTP_B.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OUTP_B",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_OUTP_B") #! Field("PPS:SYSE:1:30BSY:HRTBT_OUTP_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OUTP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi119") { field(DESC, "Port 30BSY_RDB bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 119, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B") { field(DESC, "BCS_Fault_Trigger_Output_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb119",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb119") #! Field("PLC:BSY0:PP10:30BSY_RDBb119.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb119.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb119.FLNK","PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb119.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb119.VAL") #! Record("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb119.VAL") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B_calc.OUT","PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B.VAL") #! Record("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B",500,20,0,0,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B") #! Field("PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:BCS_FAULT_TRG_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi117") { field(DESC, "Port 30BSY_RDB bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 117, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:30BSY:SECURE_COM_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:SECURE_COM_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi117 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:SECURE_COM_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:SECURE_COM_B") { field(DESC, "30BSY_Secure_Complete_B") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb117",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb117") #! Field("PLC:BSY0:PP10:30BSY_RDBb117.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb117.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb117.FLNK","PPS:SYSE:1:30BSY:SECURE_COM_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb117.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb117.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_COM_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:SECURE_COM_B_calc") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:SECURE_COM_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:SECURE_COM_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb117.VAL") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:SECURE_COM_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:SECURE_COM_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:SECURE_COM_B_calc.OUT","PPS:SYSE:1:30BSY:SECURE_COM_B.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_COM_B",500,20,0,0,"PPS:SYSE:1:30BSY:SECURE_COM_B") #! Field("PPS:SYSE:1:30BSY:SECURE_COM_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:SECURE_COM_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi116") { field(DESC, "Port 30BSY_RDB bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:SECURE_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:SECURE_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:SECURE_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:SECURE_LTH_B") { field(DESC, "30BSY_Secure_Latched_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb116",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb116") #! Field("PLC:BSY0:PP10:30BSY_RDBb116.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb116.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb116.FLNK","PPS:SYSE:1:30BSY:SECURE_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb116.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb116.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:SECURE_LTH_B_calc") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb116.VAL") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:SECURE_LTH_B_calc.OUT","PPS:SYSE:1:30BSY:SECURE_LTH_B.VAL") #! Record("PPS:SYSE:1:30BSY:SECURE_LTH_B",500,20,0,0,"PPS:SYSE:1:30BSY:SECURE_LTH_B") #! Field("PPS:SYSE:1:30BSY:SECURE_LTH_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:SECURE_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi115") { field(DESC, "Port 30BSY_RDB bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 115, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:LTU0:1:ACCPERMIT_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LTU0:1:ACCPERMIT_OUT_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LTU0:1:ACCPERMIT_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LTU0:1:ACCPERMIT_OUT_B") { field(DESC, "BTH_UND_Access_Permit_Out_B") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb115",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb115") #! Field("PLC:BSY0:PP10:30BSY_RDBb115.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb115.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb115.FLNK","PPS:LTU0:1:ACCPERMIT_OUT_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb115.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb115.VAL") #! Record("PPS:LTU0:1:ACCPERMIT_OUT_B_calc",260,18,0,1,"PPS:LTU0:1:ACCPERMIT_OUT_B_calc") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_B_calc.INPA",16777215,0,"PPS:LTU0:1:ACCPERMIT_OUT_B_calc.INPA") #! Link("PPS:LTU0:1:ACCPERMIT_OUT_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb115.VAL") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_B_calc.INPB",16777215,1,"PPS:LTU0:1:ACCPERMIT_OUT_B_calc.INPB") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_B_calc.OUT",16777215,1,"PPS:LTU0:1:ACCPERMIT_OUT_B_calc.OUT") #! Link("PPS:LTU0:1:ACCPERMIT_OUT_B_calc.OUT","PPS:LTU0:1:ACCPERMIT_OUT_B.VAL") #! Record("PPS:LTU0:1:ACCPERMIT_OUT_B",500,20,0,0,"PPS:LTU0:1:ACCPERMIT_OUT_B") #! Field("PPS:LTU0:1:ACCPERMIT_OUT_B.VAL",16777215,1,"PPS:LTU0:1:ACCPERMIT_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi114") { field(DESC, "Port 30BSY_RDB bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 114, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:LTU0:2:ACCPERMIT_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LTU0:2:ACCPERMIT_OUT_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LTU0:2:ACCPERMIT_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LTU0:2:ACCPERMIT_OUT_B") { field(DESC, "RSY_Access_Permit_Out_B") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb114",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb114") #! Field("PLC:BSY0:PP10:30BSY_RDBb114.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb114.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb114.FLNK","PPS:LTU0:2:ACCPERMIT_OUT_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb114.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb114.VAL") #! Record("PPS:LTU0:2:ACCPERMIT_OUT_B_calc",260,18,0,1,"PPS:LTU0:2:ACCPERMIT_OUT_B_calc") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_B_calc.INPA",16777215,0,"PPS:LTU0:2:ACCPERMIT_OUT_B_calc.INPA") #! Link("PPS:LTU0:2:ACCPERMIT_OUT_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb114.VAL") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_B_calc.INPB",16777215,1,"PPS:LTU0:2:ACCPERMIT_OUT_B_calc.INPB") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_B_calc.OUT",16777215,1,"PPS:LTU0:2:ACCPERMIT_OUT_B_calc.OUT") #! Link("PPS:LTU0:2:ACCPERMIT_OUT_B_calc.OUT","PPS:LTU0:2:ACCPERMIT_OUT_B.VAL") #! Record("PPS:LTU0:2:ACCPERMIT_OUT_B",500,20,0,0,"PPS:LTU0:2:ACCPERMIT_OUT_B") #! Field("PPS:LTU0:2:ACCPERMIT_OUT_B.VAL",16777215,1,"PPS:LTU0:2:ACCPERMIT_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi113") { field(DESC, "Port 30BSY_RDB bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 113, 1, 1)") field(ZNAM, "Not_Escalated") field(ONAM, "Escalated") field(FLNK, "PPS:SYSE:1:BSOIC_ESC_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BSOIC_ESC_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BSOIC_ESC_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BSOIC_ESC_B") { field(DESC, "BSOIC escalation B") field(ZNAM, "Not_Escalated") field(ONAM, "Escalated") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb113",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb113") #! Field("PLC:BSY0:PP10:30BSY_RDBb113.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb113.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb113.FLNK","PPS:SYSE:1:BSOIC_ESC_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb113.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb113.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_B_calc",260,18,0,1,"PPS:SYSE:1:BSOIC_ESC_B_calc") #! Field("PPS:SYSE:1:BSOIC_ESC_B_calc.INPA",16777215,0,"PPS:SYSE:1:BSOIC_ESC_B_calc.INPA") #! Link("PPS:SYSE:1:BSOIC_ESC_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb113.VAL") #! Field("PPS:SYSE:1:BSOIC_ESC_B_calc.INPB",16777215,1,"PPS:SYSE:1:BSOIC_ESC_B_calc.INPB") #! Field("PPS:SYSE:1:BSOIC_ESC_B_calc.OUT",16777215,1,"PPS:SYSE:1:BSOIC_ESC_B_calc.OUT") #! Link("PPS:SYSE:1:BSOIC_ESC_B_calc.OUT","PPS:SYSE:1:BSOIC_ESC_B.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_B",500,20,0,0,"PPS:SYSE:1:BSOIC_ESC_B") #! Field("PPS:SYSE:1:BSOIC_ESC_B.VAL",16777215,1,"PPS:SYSE:1:BSOIC_ESC_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi112") { field(DESC, "Port 30BSY_RDB bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 112, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi112 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:GLOBAL:BEAMCOND_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:GLOBAL:BEAMCOND_B") { field(DESC, "Global_Beam_Conditions_B") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb112",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb112") #! Field("PLC:BSY0:PP10:30BSY_RDBb112.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb112.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb112.FLNK","PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb112.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb112.VAL") #! Record("PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc",260,18,0,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.INPA",16777215,0,"PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.INPA") #! Link("PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb112.VAL") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.INPB",16777215,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.INPB") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.OUT",16777215,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.OUT") #! Link("PPS:SYSE:1:GLOBAL:BEAMCOND_B_calc.OUT","PPS:SYSE:1:GLOBAL:BEAMCOND_B.VAL") #! Record("PPS:SYSE:1:GLOBAL:BEAMCOND_B",500,20,0,0,"PPS:SYSE:1:GLOBAL:BEAMCOND_B") #! Field("PPS:SYSE:1:GLOBAL:BEAMCOND_B.VAL",16777215,1,"PPS:SYSE:1:GLOBAL:BEAMCOND_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi127") { field(DESC, "Port 30BSY_RDB bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 127, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:CU:BEAMCOND_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:BEAMCOND_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:BEAMCOND_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:BEAMCOND_B") { field(DESC, "Cu_Beam_Conditions_B") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb127",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb127") #! Field("PLC:BSY0:PP10:30BSY_RDBb127.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb127.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb127.FLNK","PPS:SYSE:1:CU:BEAMCOND_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb127.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb127.VAL") #! Record("PPS:SYSE:1:CU:BEAMCOND_B_calc",260,18,0,1,"PPS:SYSE:1:CU:BEAMCOND_B_calc") #! Field("PPS:SYSE:1:CU:BEAMCOND_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:BEAMCOND_B_calc.INPA") #! Link("PPS:SYSE:1:CU:BEAMCOND_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb127.VAL") #! Field("PPS:SYSE:1:CU:BEAMCOND_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:BEAMCOND_B_calc.INPB") #! Field("PPS:SYSE:1:CU:BEAMCOND_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:BEAMCOND_B_calc.OUT") #! Link("PPS:SYSE:1:CU:BEAMCOND_B_calc.OUT","PPS:SYSE:1:CU:BEAMCOND_B.VAL") #! Record("PPS:SYSE:1:CU:BEAMCOND_B",500,20,0,0,"PPS:SYSE:1:CU:BEAMCOND_B") #! Field("PPS:SYSE:1:CU:BEAMCOND_B.VAL",16777215,1,"PPS:SYSE:1:CU:BEAMCOND_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi126") { field(DESC, "Port 30BSY_RDB bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 126, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:SYSE:1:SC:BEAMCOND_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SC:BEAMCOND_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi126 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SC:BEAMCOND_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SC:BEAMCOND_B") { field(DESC, "SC_Beam_Conditions_B") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb126",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb126") #! Field("PLC:BSY0:PP10:30BSY_RDBb126.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb126.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb126.FLNK","PPS:SYSE:1:SC:BEAMCOND_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb126.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb126.VAL") #! Record("PPS:SYSE:1:SC:BEAMCOND_B_calc",260,18,0,1,"PPS:SYSE:1:SC:BEAMCOND_B_calc") #! Field("PPS:SYSE:1:SC:BEAMCOND_B_calc.INPA",16777215,0,"PPS:SYSE:1:SC:BEAMCOND_B_calc.INPA") #! Link("PPS:SYSE:1:SC:BEAMCOND_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb126.VAL") #! Field("PPS:SYSE:1:SC:BEAMCOND_B_calc.INPB",16777215,1,"PPS:SYSE:1:SC:BEAMCOND_B_calc.INPB") #! Field("PPS:SYSE:1:SC:BEAMCOND_B_calc.OUT",16777215,1,"PPS:SYSE:1:SC:BEAMCOND_B_calc.OUT") #! Link("PPS:SYSE:1:SC:BEAMCOND_B_calc.OUT","PPS:SYSE:1:SC:BEAMCOND_B.VAL") #! Record("PPS:SYSE:1:SC:BEAMCOND_B",500,20,0,0,"PPS:SYSE:1:SC:BEAMCOND_B") #! Field("PPS:SYSE:1:SC:BEAMCOND_B.VAL",16777215,1,"PPS:SYSE:1:SC:BEAMCOND_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi123") { field(DESC, "Port 30BSY_RDB bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 123, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:BLM_INP_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BLM_INP_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BLM_INP_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BLM_INP_LTH_B") { field(DESC, "BCS_BLM_Input_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb123",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb123") #! Field("PLC:BSY0:PP10:30BSY_RDBb123.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb123.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb123.FLNK","PPS:SYSE:1:BLM_INP_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb123.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb123.VAL") #! Record("PPS:SYSE:1:BLM_INP_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:BLM_INP_LTH_B_calc") #! Field("PPS:SYSE:1:BLM_INP_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:BLM_INP_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:BLM_INP_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb123.VAL") #! Field("PPS:SYSE:1:BLM_INP_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:BLM_INP_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:BLM_INP_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:BLM_INP_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:BLM_INP_LTH_B_calc.OUT","PPS:SYSE:1:BLM_INP_LTH_B.VAL") #! Record("PPS:SYSE:1:BLM_INP_LTH_B",500,20,0,0,"PPS:SYSE:1:BLM_INP_LTH_B") #! Field("PPS:SYSE:1:BLM_INP_LTH_B.VAL",16777215,1,"PPS:SYSE:1:BLM_INP_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi121") { field(DESC, "Port 30BSY_RDB bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 121, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI30:1:SECURE_INP_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:1:SECURE_INP_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:1:SECURE_INP_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:1:SECURE_INP_LTH_B") { field(DESC, "S30_Secure_Input_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb121",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb121") #! Field("PLC:BSY0:PP10:30BSY_RDBb121.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb121.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb121.FLNK","PPS:LI30:1:SECURE_INP_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb121.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb121.VAL") #! Record("PPS:LI30:1:SECURE_INP_LTH_B_calc",260,18,0,1,"PPS:LI30:1:SECURE_INP_LTH_B_calc") #! Field("PPS:LI30:1:SECURE_INP_LTH_B_calc.INPA",16777215,0,"PPS:LI30:1:SECURE_INP_LTH_B_calc.INPA") #! Link("PPS:LI30:1:SECURE_INP_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb121.VAL") #! Field("PPS:LI30:1:SECURE_INP_LTH_B_calc.INPB",16777215,1,"PPS:LI30:1:SECURE_INP_LTH_B_calc.INPB") #! Field("PPS:LI30:1:SECURE_INP_LTH_B_calc.OUT",16777215,1,"PPS:LI30:1:SECURE_INP_LTH_B_calc.OUT") #! Link("PPS:LI30:1:SECURE_INP_LTH_B_calc.OUT","PPS:LI30:1:SECURE_INP_LTH_B.VAL") #! Record("PPS:LI30:1:SECURE_INP_LTH_B",500,20,0,0,"PPS:LI30:1:SECURE_INP_LTH_B") #! Field("PPS:LI30:1:SECURE_INP_LTH_B.VAL",16777215,1,"PPS:LI30:1:SECURE_INP_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi120") { field(DESC, "Port 30BSY_RDB bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 120, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSY0:1:SECURE_INP_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSY0:1:SECURE_INP_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSY0:1:SECURE_INP_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSY0:1:SECURE_INP_LTH_B") { field(DESC, "BSY_Secure_Input_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb120",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb120") #! Field("PLC:BSY0:PP10:30BSY_RDBb120.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb120.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb120.FLNK","PPS:BSY0:1:SECURE_INP_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb120.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb120.VAL") #! Record("PPS:BSY0:1:SECURE_INP_LTH_B_calc",260,18,0,1,"PPS:BSY0:1:SECURE_INP_LTH_B_calc") #! Field("PPS:BSY0:1:SECURE_INP_LTH_B_calc.INPA",16777215,0,"PPS:BSY0:1:SECURE_INP_LTH_B_calc.INPA") #! Link("PPS:BSY0:1:SECURE_INP_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb120.VAL") #! Field("PPS:BSY0:1:SECURE_INP_LTH_B_calc.INPB",16777215,1,"PPS:BSY0:1:SECURE_INP_LTH_B_calc.INPB") #! Field("PPS:BSY0:1:SECURE_INP_LTH_B_calc.OUT",16777215,1,"PPS:BSY0:1:SECURE_INP_LTH_B_calc.OUT") #! Link("PPS:BSY0:1:SECURE_INP_LTH_B_calc.OUT","PPS:BSY0:1:SECURE_INP_LTH_B.VAL") #! Record("PPS:BSY0:1:SECURE_INP_LTH_B",500,20,0,0,"PPS:BSY0:1:SECURE_INP_LTH_B") #! Field("PPS:BSY0:1:SECURE_INP_LTH_B.VAL",16777215,1,"PPS:BSY0:1:SECURE_INP_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi135") { field(DESC, "Port 30BSY_RDB bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 135, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:ESA0:1:RADREADY_INP_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:ESA0:1:RADREADY_INP_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:ESA0:1:RADREADY_INP_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:ESA0:1:RADREADY_INP_LTH_B") { field(DESC, "ESA_Rad_Ready_Input_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb135",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb135") #! Field("PLC:BSY0:PP10:30BSY_RDBb135.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb135.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb135.FLNK","PPS:ESA0:1:RADREADY_INP_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb135.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb135.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_LTH_B_calc",260,18,0,1,"PPS:ESA0:1:RADREADY_INP_LTH_B_calc") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_B_calc.INPA",16777215,0,"PPS:ESA0:1:RADREADY_INP_LTH_B_calc.INPA") #! Link("PPS:ESA0:1:RADREADY_INP_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb135.VAL") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_B_calc.INPB",16777215,1,"PPS:ESA0:1:RADREADY_INP_LTH_B_calc.INPB") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_B_calc.OUT",16777215,1,"PPS:ESA0:1:RADREADY_INP_LTH_B_calc.OUT") #! Link("PPS:ESA0:1:RADREADY_INP_LTH_B_calc.OUT","PPS:ESA0:1:RADREADY_INP_LTH_B.VAL") #! Record("PPS:ESA0:1:RADREADY_INP_LTH_B",500,20,0,0,"PPS:ESA0:1:RADREADY_INP_LTH_B") #! Field("PPS:ESA0:1:RADREADY_INP_LTH_B.VAL",16777215,1,"PPS:ESA0:1:RADREADY_INP_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi134") { field(DESC, "Port 30BSY_RDB bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 134, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BTM:BSY0:1:SUM_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSY0:1:SUM_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSY0:1:SUM_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "BTM:BSY0:1:SUM_OK_LTH_B") { field(DESC, "BTM_Sum_OK_Input_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb134",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb134") #! Field("PLC:BSY0:PP10:30BSY_RDBb134.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb134.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb134.FLNK","BTM:BSY0:1:SUM_OK_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb134.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb134.VAL") #! Record("BTM:BSY0:1:SUM_OK_LTH_B_calc",260,18,0,1,"BTM:BSY0:1:SUM_OK_LTH_B_calc") #! Field("BTM:BSY0:1:SUM_OK_LTH_B_calc.INPA",16777215,0,"BTM:BSY0:1:SUM_OK_LTH_B_calc.INPA") #! Link("BTM:BSY0:1:SUM_OK_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb134.VAL") #! Field("BTM:BSY0:1:SUM_OK_LTH_B_calc.INPB",16777215,1,"BTM:BSY0:1:SUM_OK_LTH_B_calc.INPB") #! Field("BTM:BSY0:1:SUM_OK_LTH_B_calc.OUT",16777215,1,"BTM:BSY0:1:SUM_OK_LTH_B_calc.OUT") #! Link("BTM:BSY0:1:SUM_OK_LTH_B_calc.OUT","BTM:BSY0:1:SUM_OK_LTH_B.VAL") #! Record("BTM:BSY0:1:SUM_OK_LTH_B",500,20,0,0,"BTM:BSY0:1:SUM_OK_LTH_B") #! Field("BTM:BSY0:1:SUM_OK_LTH_B.VAL",16777215,1,"BTM:BSY0:1:SUM_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi133") { field(DESC, "Port 30BSY_RDB bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 133, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "BSOC:SYSE:1:GROUPC_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:SYSE:1:GROUPC_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:SYSE:1:GROUPC_LTH_B PP MS") field(ASG, "Internal") } record(bi, "BSOC:SYSE:1:GROUPC_LTH_B") { field(DESC, "BSOIC_GrpC_OK_Input_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb133",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb133") #! Field("PLC:BSY0:PP10:30BSY_RDBb133.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb133.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb133.FLNK","BSOC:SYSE:1:GROUPC_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb133.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb133.VAL") #! Record("BSOC:SYSE:1:GROUPC_LTH_B_calc",260,18,0,1,"BSOC:SYSE:1:GROUPC_LTH_B_calc") #! Field("BSOC:SYSE:1:GROUPC_LTH_B_calc.INPA",16777215,0,"BSOC:SYSE:1:GROUPC_LTH_B_calc.INPA") #! Link("BSOC:SYSE:1:GROUPC_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb133.VAL") #! Field("BSOC:SYSE:1:GROUPC_LTH_B_calc.INPB",16777215,1,"BSOC:SYSE:1:GROUPC_LTH_B_calc.INPB") #! Field("BSOC:SYSE:1:GROUPC_LTH_B_calc.OUT",16777215,1,"BSOC:SYSE:1:GROUPC_LTH_B_calc.OUT") #! Link("BSOC:SYSE:1:GROUPC_LTH_B_calc.OUT","BSOC:SYSE:1:GROUPC_LTH_B.VAL") #! Record("BSOC:SYSE:1:GROUPC_LTH_B",500,20,0,0,"BSOC:SYSE:1:GROUPC_LTH_B") #! Field("BSOC:SYSE:1:GROUPC_LTH_B.VAL",16777215,1,"BSOC:SYSE:1:GROUPC_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi132") { field(DESC, "Port 30BSY_RDB bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 132, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:UND0:1:SECURE_INP_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:UND0:1:SECURE_INP_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:UND0:1:SECURE_INP_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:UND0:1:SECURE_INP_LTH_B") { field(DESC, "LCLS_Secure_Input_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb132",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb132") #! Field("PLC:BSY0:PP10:30BSY_RDBb132.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb132.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb132.FLNK","PPS:UND0:1:SECURE_INP_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb132.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb132.VAL") #! Record("PPS:UND0:1:SECURE_INP_LTH_B_calc",260,18,0,1,"PPS:UND0:1:SECURE_INP_LTH_B_calc") #! Field("PPS:UND0:1:SECURE_INP_LTH_B_calc.INPA",16777215,0,"PPS:UND0:1:SECURE_INP_LTH_B_calc.INPA") #! Link("PPS:UND0:1:SECURE_INP_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb132.VAL") #! Field("PPS:UND0:1:SECURE_INP_LTH_B_calc.INPB",16777215,1,"PPS:UND0:1:SECURE_INP_LTH_B_calc.INPB") #! Field("PPS:UND0:1:SECURE_INP_LTH_B_calc.OUT",16777215,1,"PPS:UND0:1:SECURE_INP_LTH_B_calc.OUT") #! Link("PPS:UND0:1:SECURE_INP_LTH_B_calc.OUT","PPS:UND0:1:SECURE_INP_LTH_B.VAL") #! Record("PPS:UND0:1:SECURE_INP_LTH_B",500,20,0,0,"PPS:UND0:1:SECURE_INP_LTH_B") #! Field("PPS:UND0:1:SECURE_INP_LTH_B.VAL",16777215,1,"PPS:UND0:1:SECURE_INP_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi131") { field(DESC, "Port 30BSY_RDB bit 131") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 131, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi131 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B") { field(DESC, "Local_Beam_Enable_Keysw_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb131",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb131") #! Field("PLC:BSY0:PP10:30BSY_RDBb131.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb131.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb131.FLNK","PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb131.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb131.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb131.VAL") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B_calc.OUT","PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B.VAL") #! Record("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B",500,20,0,0,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B") #! Field("PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:LOCAL_ENABLE_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi130") { field(DESC, "Port 30BSY_RDB bit 130") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 130, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:BSOIC_ESC_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BSOIC_ESC_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi130 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BSOIC_ESC_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BSOIC_ESC_LTH_B") { field(DESC, "BSOIC escalation Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb130",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb130") #! Field("PLC:BSY0:PP10:30BSY_RDBb130.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb130.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb130.FLNK","PPS:SYSE:1:BSOIC_ESC_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb130.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb130.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:BSOIC_ESC_LTH_B_calc") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb130.VAL") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:BSOIC_ESC_LTH_B_calc.OUT","PPS:SYSE:1:BSOIC_ESC_LTH_B.VAL") #! Record("PPS:SYSE:1:BSOIC_ESC_LTH_B",500,20,0,0,"PPS:SYSE:1:BSOIC_ESC_LTH_B") #! Field("PPS:SYSE:1:BSOIC_ESC_LTH_B.VAL",16777215,1,"PPS:SYSE:1:BSOIC_ESC_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi129") { field(DESC, "Port 30BSY_RDB bit 129") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 129, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:BCS_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:BCS_FAULT_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi129 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:BCS_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:BCS_FAULT_LTH_B") { field(DESC, "BCS BEAM ON Fault B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb129",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb129") #! Field("PLC:BSY0:PP10:30BSY_RDBb129.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb129.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb129.FLNK","PPS:SYSE:1:BCS_FAULT_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb129.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb129.VAL") #! Record("PPS:SYSE:1:BCS_FAULT_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:BCS_FAULT_LTH_B_calc") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:BCS_FAULT_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:BCS_FAULT_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb129.VAL") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:BCS_FAULT_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:BCS_FAULT_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:BCS_FAULT_LTH_B_calc.OUT","PPS:SYSE:1:BCS_FAULT_LTH_B.VAL") #! Record("PPS:SYSE:1:BCS_FAULT_LTH_B",500,20,0,0,"PPS:SYSE:1:BCS_FAULT_LTH_B") #! Field("PPS:SYSE:1:BCS_FAULT_LTH_B.VAL",16777215,1,"PPS:SYSE:1:BCS_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi128") { field(DESC, "Port 30BSY_RDB bit 128") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 128, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi128 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B") { field(DESC, "ACR_Beam_Enable_Keysw_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb128",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb128") #! Field("PLC:BSY0:PP10:30BSY_RDBb128.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb128.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb128.FLNK","PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb128.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb128.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb128.VAL") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B_calc.OUT","PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B.VAL") #! Record("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B",500,20,0,0,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B") #! Field("PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:ACR_ENABLE_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi143") { field(DESC, "Port 30BSY_RDB bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 143, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:INTLK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:INTLK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:INTLK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:INTLK_LTH_B") { field(DESC, "30-BSY Glbl. intlk (spare) B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb143",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb143") #! Field("PLC:BSY0:PP10:30BSY_RDBb143.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb143.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb143.FLNK","PPS:SYSE:1:30BSY:INTLK_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb143.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb143.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:INTLK_LTH_B_calc") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb143.VAL") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:INTLK_LTH_B_calc.OUT","PPS:SYSE:1:30BSY:INTLK_LTH_B.VAL") #! Record("PPS:SYSE:1:30BSY:INTLK_LTH_B",500,20,0,0,"PPS:SYSE:1:30BSY:INTLK_LTH_B") #! Field("PPS:SYSE:1:30BSY:INTLK_LTH_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:INTLK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi142") { field(DESC, "Port 30BSY_RDB bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 142, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:CU:BEAMOK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:BEAMOK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:BEAMOK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:BEAMOK_LTH_B") { field(DESC, "Cu beam config OK (spare) B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb142",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb142") #! Field("PLC:BSY0:PP10:30BSY_RDBb142.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb142.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb142.FLNK","PPS:SYSE:1:CU:BEAMOK_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb142.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb142.VAL") #! Record("PPS:SYSE:1:CU:BEAMOK_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:CU:BEAMOK_LTH_B_calc") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb142.VAL") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:CU:BEAMOK_LTH_B_calc.OUT","PPS:SYSE:1:CU:BEAMOK_LTH_B.VAL") #! Record("PPS:SYSE:1:CU:BEAMOK_LTH_B",500,20,0,0,"PPS:SYSE:1:CU:BEAMOK_LTH_B") #! Field("PPS:SYSE:1:CU:BEAMOK_LTH_B.VAL",16777215,1,"PPS:SYSE:1:CU:BEAMOK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi141") { field(DESC, "Port 30BSY_RDB bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 141, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:SC:BEAMOK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:SC:BEAMOK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:SC:BEAMOK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:SC:BEAMOK_LTH_B") { field(DESC, "SC beam config OK (spare) B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb141",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb141") #! Field("PLC:BSY0:PP10:30BSY_RDBb141.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb141.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb141.FLNK","PPS:SYSE:1:SC:BEAMOK_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb141.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb141.VAL") #! Record("PPS:SYSE:1:SC:BEAMOK_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:SC:BEAMOK_LTH_B_calc") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb141.VAL") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:SC:BEAMOK_LTH_B_calc.OUT","PPS:SYSE:1:SC:BEAMOK_LTH_B.VAL") #! Record("PPS:SYSE:1:SC:BEAMOK_LTH_B",500,20,0,0,"PPS:SYSE:1:SC:BEAMOK_LTH_B") #! Field("PPS:SYSE:1:SC:BEAMOK_LTH_B.VAL",16777215,1,"PPS:SYSE:1:SC:BEAMOK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi139") { field(DESC, "Port 30BSY_RDB bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 139, 1, 1)") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_OK_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_OK_B") { field(DESC, "Heartbeat OK B") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb139",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb139") #! Field("PLC:BSY0:PP10:30BSY_RDBb139.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb139.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb139.FLNK","PPS:SYSE:1:30BSY:HRTBT_OK_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb139.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb139.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_OK_B_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb139.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_B_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_OK_B.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_B",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_OK_B") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi138") { field(DESC, "Port 30BSY_RDB bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:SYSE:1:INSERT_FAILED_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:SYSE:1:INSERT_FAILED_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:SYSE:1:INSERT_FAILED_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:SYSE:1:INSERT_FAILED_LTH_B") { field(DESC, "Stopper_Insert_Failed_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb138",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb138") #! Field("PLC:BSY0:PP10:30BSY_RDBb138.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb138.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb138.FLNK","STPR:SYSE:1:INSERT_FAILED_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb138.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb138.VAL") #! Record("STPR:SYSE:1:INSERT_FAILED_LTH_B_calc",260,18,0,1,"STPR:SYSE:1:INSERT_FAILED_LTH_B_calc") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.INPA",16777215,0,"STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.INPA") #! Link("STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb138.VAL") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.INPB",16777215,1,"STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.INPB") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.OUT",16777215,1,"STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.OUT") #! Link("STPR:SYSE:1:INSERT_FAILED_LTH_B_calc.OUT","STPR:SYSE:1:INSERT_FAILED_LTH_B.VAL") #! Record("STPR:SYSE:1:INSERT_FAILED_LTH_B",500,20,0,0,"STPR:SYSE:1:INSERT_FAILED_LTH_B") #! Field("STPR:SYSE:1:INSERT_FAILED_LTH_B.VAL",16777215,1,"STPR:SYSE:1:INSERT_FAILED_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi137") { field(DESC, "Port 30BSY_RDB bit 137") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 137, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi137 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B") { field(DESC, "Heartbeat OK Latched B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb137",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb137") #! Field("PLC:BSY0:PP10:30BSY_RDBb137.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb137.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb137.FLNK","PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb137.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb137.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb137.VAL") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B_calc.OUT","PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B.VAL") #! Record("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B",500,20,0,0,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B") #! Field("PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B.VAL",16777215,1,"PPS:SYSE:1:30BSY:HRTBT_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi136") { field(DESC, "Port 30BSY_RDB bit 136") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 136, 1, 1)") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(FLNK, "PPS:SYSE:1:CU:HXR_CLEAR_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:HXR_CLEAR_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi136 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:HXR_CLEAR_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:HXR_CLEAR_B") { field(DESC, "Cu line cleared to HXR B") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb136",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb136") #! Field("PLC:BSY0:PP10:30BSY_RDBb136.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb136.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb136.FLNK","PPS:SYSE:1:CU:HXR_CLEAR_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb136.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb136.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_B_calc",260,18,0,1,"PPS:SYSE:1:CU:HXR_CLEAR_B_calc") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:HXR_CLEAR_B_calc.INPA") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb136.VAL") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_B_calc.INPB") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_B_calc.OUT") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_B_calc.OUT","PPS:SYSE:1:CU:HXR_CLEAR_B.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_B",500,20,0,0,"PPS:SYSE:1:CU:HXR_CLEAR_B") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_B.VAL",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi151") { field(DESC, "Port 30BSY_RDB bit 151") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 151, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi151 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:HXR_CLEAR_LTH_B") { field(DESC, "Cu line cleared to HXR Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb151",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb151") #! Field("PLC:BSY0:PP10:30BSY_RDBb151.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb151.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb151.FLNK","PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb151.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb151.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb151.VAL") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B_calc.OUT","PPS:SYSE:1:CU:HXR_CLEAR_LTH_B.VAL") #! Record("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B",500,20,0,0,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_B") #! Field("PPS:SYSE:1:CU:HXR_CLEAR_LTH_B.VAL",16777215,1,"PPS:SYSE:1:CU:HXR_CLEAR_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi150") { field(DESC, "Port 30BSY_RDB bit 150") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 150, 1, 1)") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(FLNK, "PPS:SYSE:1:CU:SXR_CLEAR_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:SXR_CLEAR_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi150 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:SXR_CLEAR_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:SXR_CLEAR_B") { field(DESC, "Cu line cleared to SXR B") field(ZNAM, "Not_Cleared") field(ONAM, "Cleared") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb150",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb150") #! Field("PLC:BSY0:PP10:30BSY_RDBb150.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb150.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb150.FLNK","PPS:SYSE:1:CU:SXR_CLEAR_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb150.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb150.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_B_calc",260,18,0,1,"PPS:SYSE:1:CU:SXR_CLEAR_B_calc") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:SXR_CLEAR_B_calc.INPA") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb150.VAL") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_B_calc.INPB") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_B_calc.OUT") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_B_calc.OUT","PPS:SYSE:1:CU:SXR_CLEAR_B.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_B",500,20,0,0,"PPS:SYSE:1:CU:SXR_CLEAR_B") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_B.VAL",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP10:Bi149") { field(DESC, "Port 30BSY_RDB bit 149") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 149, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc") { field(INPA, "PLC:BSY0:PP10:Bi149 NPP MS") field(INPB, "PLC:BSY0:PP10:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:SYSE:1:CU:SXR_CLEAR_LTH_B") { field(DESC, "Cu line cleared to SXR Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP10:30BSY_RDBb149",20,19,0,0,"PLC:BSY0:PP10:30BSY_RDBb149") #! Field("PLC:BSY0:PP10:30BSY_RDBb149.FLNK",16777215,1,"PLC:BSY0:PP10:30BSY_RDBb149.FLNK") #! Link("PLC:BSY0:PP10:30BSY_RDBb149.FLNK","PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc") #! Field("PLC:BSY0:PP10:30BSY_RDBb149.VAL",16777215,0,"PLC:BSY0:PP10:30BSY_RDBb149.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc",260,18,0,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.INPA",16777215,0,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.INPA") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.INPA","PLC:BSY0:PP10:30BSY_RDBb149.VAL") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.INPB",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.INPB") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.OUT",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.OUT") #! Link("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B_calc.OUT","PPS:SYSE:1:CU:SXR_CLEAR_LTH_B.VAL") #! Record("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B",500,20,0,0,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_B") #! Field("PPS:SYSE:1:CU:SXR_CLEAR_LTH_B.VAL",16777215,1,"PPS:SYSE:1:CU:SXR_CLEAR_LTH_B.VAL") record(bo, "PPS:SYSE:1:30BSY:RESET_INTLK_B") { field(DESC, "PPS_Interlock_Reset_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:SYSE:1:30BSY:PAUSEHB_B") { field(DESC, "PPS_Pause_Heartbeat_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP10:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP10:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP10:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP10:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP10:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP10:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP10:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP10:REQ_SEG CP") field( INPC, "PLC:BSY0:PP10:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP10:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP10:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP10:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP10:REQ_SEG CP") field( INPC, "PLC:BSY0:PP10:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP10:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP10:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP10:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP10:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP10:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP10:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP10:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP10:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP10:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP10:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP10:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP10:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP10:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP10:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP10:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP10:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP10:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP10:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP10:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP10:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP10:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP10:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP10:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP10:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP10:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP10:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP10:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP10:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP10:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP10:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP10:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP10:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP10:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP10:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP10:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP10:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP10:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP10:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP10:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP10:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP10:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP10:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP10:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP10:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP10:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP10:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP10:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP10:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP10:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP10:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP10:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP10:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP10:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_RDB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP10:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(30BSY_WRTB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP10:w0") { field(DESC, "S30 BSY CHB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:w1") { field(DESC, "S30 BSY CHB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP10:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP10:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP10:w3") { field(DESC, "S30 BSY CHB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP10:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP10:w3 PP MS") field(INPB, "PLC:BSY0:PP10:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP10:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP10:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP10:w4") { field(DESC, "S30 BSY CHB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP10:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP10:w4 NPP MS") field(INPB, "PLC:BSY0:PP10:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP10:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP10:w5") { field(DESC, "S30 BSY CHB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP10:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP10:w5 NPP MS") field(INPB, "PLC:BSY0:PP10:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP10:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP10:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP10:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP10:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP10:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP10:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP10:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP10:w6 NPP MS") field(INPB, "PLC:BSY0:PP10:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP10:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP10:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP10:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP10:w7 NPP MS") field(INPB, "PLC:BSY0:PP10:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP10:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(30BSY_WDB, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP10:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP10:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP10:w8 NPP MS") field(INPB, "PLC:BSY0:PP10:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP10:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP10:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP10:OP_HOURS") { field(INPA, "PLC:BSY0:PP10:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP10:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP10:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP10:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP10:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(30BSY_RDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP10:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP10:RDHist.PROC") } record(waveform,"PLC:BSY0:PP10:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_RDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP10:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP10:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_RDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP10:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP10:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(30BSY_RDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP10:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP10:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP10:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP10:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP10:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP10:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP10:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP10:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP10:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_RDB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP10:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(30BSY_WRTB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP10:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP10:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP10:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WRTB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP10:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP10:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WRTB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP10:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP10:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(30BSY_WRTB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP10:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTB 0)READ_OK") field(FLNK,"PLC:BSY0:PP10:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP10:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP10:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP10:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP10:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP10:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP10:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP10:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WRTB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP10:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(30BSY_WDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP10:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP10:WDHist.PROC") } record(waveform,"PLC:BSY0:PP10:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP10:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP10:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(30BSY_WDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP10:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP10:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(30BSY_WDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP10:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP10:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP10:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP10:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP10:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP10:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP10:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP10:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP10:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(30BSY_WDB 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi7") { field(DESC, "Port ST34_RDA bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:ST34:HW_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HW_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HW_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HW_ENABLE_A") { field(DESC, "HW Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb7",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb7") #! Field("PLC:BSY0:PP07:ST34_RDAb7.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb7.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb7.FLNK","PPS:BSYS:1:ST34:HW_ENABLE_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb7.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb7.VAL") #! Record("PPS:BSYS:1:ST34:HW_ENABLE_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:HW_ENABLE_A_calc") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HW_ENABLE_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:HW_ENABLE_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb7.VAL") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HW_ENABLE_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HW_ENABLE_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:HW_ENABLE_A_calc.OUT","PPS:BSYS:1:ST34:HW_ENABLE_A.VAL") #! Record("PPS:BSYS:1:ST34:HW_ENABLE_A",500,20,0,0,"PPS:BSYS:1:ST34:HW_ENABLE_A") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_A.VAL",16777215,1,"PPS:BSYS:1:ST34:HW_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi6") { field(DESC, "Port ST34_RDA bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 6, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:XINTLK_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:XINTLK_IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:XINTLK_IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:XINTLK_IN_A") { field(DESC, "STP-34 Cross-interlock input") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb6",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb6") #! Field("PLC:BSY0:PP07:ST34_RDAb6.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb6.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb6.FLNK","PPS:BSYS:1:ST34:XINTLK_IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb6.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb6.VAL") #! Record("PPS:BSYS:1:ST34:XINTLK_IN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:XINTLK_IN_A_calc") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:XINTLK_IN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:XINTLK_IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb6.VAL") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:XINTLK_IN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:XINTLK_IN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:XINTLK_IN_A_calc.OUT","PPS:BSYS:1:ST34:XINTLK_IN_A.VAL") #! Record("PPS:BSYS:1:ST34:XINTLK_IN_A",500,20,0,0,"PPS:BSYS:1:ST34:XINTLK_IN_A") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_A.VAL",16777215,1,"PPS:BSYS:1:ST34:XINTLK_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi5") { field(DESC, "Port ST34_RDA bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 5, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:BSYS:1:ST34:LCLS_SECURE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:LCLS_SECURE_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:LCLS_SECURE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:LCLS_SECURE_A") { field(DESC, "LCLS Secure") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb5",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb5") #! Field("PLC:BSY0:PP07:ST34_RDAb5.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb5.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb5.FLNK","PPS:BSYS:1:ST34:LCLS_SECURE_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb5.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb5.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:LCLS_SECURE_A_calc") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb5.VAL") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_A_calc.OUT","PPS:BSYS:1:ST34:LCLS_SECURE_A.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_A",500,20,0,0,"PPS:BSYS:1:ST34:LCLS_SECURE_A") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_A.VAL",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi4") { field(DESC, "Port ST34_RDA bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 4, 1, 1)") field(ZNAM, "Not_OK") field(ONAM, "OK") field(FLNK, "PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi4 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BSOICS_C_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BSOICS_C_OK_A") { field(DESC, "BSOICS Group-C OK") field(ZNAM, "Not_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb4",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb4") #! Field("PLC:BSY0:PP07:ST34_RDAb4.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb4.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb4.FLNK","PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb4.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb4.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb4.VAL") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_A_calc.OUT","PPS:BSYS:1:ST34:BSOICS_C_OK_A.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_A",500,20,0,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_A") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi3") { field(DESC, "Port ST34_RDA bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 3, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:ST34:ADMIN_EN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:ADMIN_EN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi3 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:ADMIN_EN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:ADMIN_EN_A") { field(DESC, "SXR Admn Enable Key (ANR & NEH)(ST34)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb3",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb3") #! Field("PLC:BSY0:PP07:ST34_RDAb3.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb3.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb3.FLNK","PPS:BSYS:1:ST34:ADMIN_EN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb3.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb3.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:ADMIN_EN_A_calc") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:ADMIN_EN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb3.VAL") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_A_calc.OUT","PPS:BSYS:1:ST34:ADMIN_EN_A.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_A",500,20,0,0,"PPS:BSYS:1:ST34:ADMIN_EN_A") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_A.VAL",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi2") { field(DESC, "Port ST34_RDA bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 2, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI30:5:SXR:KICKSEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:5:SXR:KICKSEP_OFF_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:5:SXR:KICKSEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:5:SXR:KICKSEP_OFF_A") { field(DESC, "SX-Kicker/Septum Summary OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb2",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb2") #! Field("PLC:BSY0:PP07:ST34_RDAb2.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb2.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb2.FLNK","PPS:LI30:5:SXR:KICKSEP_OFF_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb2.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb2.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_A_calc",260,18,0,1,"PPS:LI30:5:SXR:KICKSEP_OFF_A_calc") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.INPA",16777215,0,"PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.INPA") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb2.VAL") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.INPB",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.INPB") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.OUT",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.OUT") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_A_calc.OUT","PPS:LI30:5:SXR:KICKSEP_OFF_A.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_A",500,20,0,0,"PPS:LI30:5:SXR:KICKSEP_OFF_A") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_A.VAL",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi1") { field(DESC, "Port ST34_RDA bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 1, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:KICK_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:KICK_OFF_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:KICK_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:KICK_OFF_A") { field(DESC, "CL-Kicker OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb1",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb1") #! Field("PLC:BSY0:PP07:ST34_RDAb1.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb1.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb1.FLNK","PPS:CLTS:5:KICK_OFF_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb1.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb1.VAL") #! Record("PPS:CLTS:5:KICK_OFF_A_calc",260,18,0,1,"PPS:CLTS:5:KICK_OFF_A_calc") #! Field("PPS:CLTS:5:KICK_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:5:KICK_OFF_A_calc.INPA") #! Link("PPS:CLTS:5:KICK_OFF_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb1.VAL") #! Field("PPS:CLTS:5:KICK_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:5:KICK_OFF_A_calc.INPB") #! Field("PPS:CLTS:5:KICK_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:5:KICK_OFF_A_calc.OUT") #! Link("PPS:CLTS:5:KICK_OFF_A_calc.OUT","PPS:CLTS:5:KICK_OFF_A.VAL") #! Record("PPS:CLTS:5:KICK_OFF_A",500,20,0,0,"PPS:CLTS:5:KICK_OFF_A") #! Field("PPS:CLTS:5:KICK_OFF_A.VAL",16777215,1,"PPS:CLTS:5:KICK_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi0") { field(DESC, "Port ST34_RDA bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 0, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:DCBEND_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:DCBEND_OFF_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:DCBEND_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:DCBEND_OFF_A") { field(DESC, "CL-DC OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb0",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb0") #! Field("PLC:BSY0:PP07:ST34_RDAb0.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb0.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb0.FLNK","PPS:CLTS:5:DCBEND_OFF_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb0.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb0.VAL") #! Record("PPS:CLTS:5:DCBEND_OFF_A_calc",260,18,0,1,"PPS:CLTS:5:DCBEND_OFF_A_calc") #! Field("PPS:CLTS:5:DCBEND_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:5:DCBEND_OFF_A_calc.INPA") #! Link("PPS:CLTS:5:DCBEND_OFF_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb0.VAL") #! Field("PPS:CLTS:5:DCBEND_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:5:DCBEND_OFF_A_calc.INPB") #! Field("PPS:CLTS:5:DCBEND_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:5:DCBEND_OFF_A_calc.OUT") #! Link("PPS:CLTS:5:DCBEND_OFF_A_calc.OUT","PPS:CLTS:5:DCBEND_OFF_A.VAL") #! Record("PPS:CLTS:5:DCBEND_OFF_A",500,20,0,0,"PPS:CLTS:5:DCBEND_OFF_A") #! Field("PPS:CLTS:5:DCBEND_OFF_A.VAL",16777215,1,"PPS:CLTS:5:DCBEND_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi15") { field(DESC, "Port ST34_RDA bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 15, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:SEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:SEP_OFF_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:SEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:SEP_OFF_A") { field(DESC, "CL-Septum OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb15",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb15") #! Field("PLC:BSY0:PP07:ST34_RDAb15.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb15.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb15.FLNK","PPS:CLTS:5:SEP_OFF_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb15.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb15.VAL") #! Record("PPS:CLTS:5:SEP_OFF_A_calc",260,18,0,1,"PPS:CLTS:5:SEP_OFF_A_calc") #! Field("PPS:CLTS:5:SEP_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:5:SEP_OFF_A_calc.INPA") #! Link("PPS:CLTS:5:SEP_OFF_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb15.VAL") #! Field("PPS:CLTS:5:SEP_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:5:SEP_OFF_A_calc.INPB") #! Field("PPS:CLTS:5:SEP_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:5:SEP_OFF_A_calc.OUT") #! Link("PPS:CLTS:5:SEP_OFF_A_calc.OUT","PPS:CLTS:5:SEP_OFF_A.VAL") #! Record("PPS:CLTS:5:SEP_OFF_A",500,20,0,0,"PPS:CLTS:5:SEP_OFF_A") #! Field("PPS:CLTS:5:SEP_OFF_A.VAL",16777215,1,"PPS:CLTS:5:SEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi14") { field(DESC, "Port ST34_RDA bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 14, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:MERGE_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:MERGE_OFF_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:MERGE_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:MERGE_OFF_A") { field(DESC, "CL-Merge OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb14",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb14") #! Field("PLC:BSY0:PP07:ST34_RDAb14.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb14.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb14.FLNK","PPS:CLTS:5:MERGE_OFF_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb14.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb14.VAL") #! Record("PPS:CLTS:5:MERGE_OFF_A_calc",260,18,0,1,"PPS:CLTS:5:MERGE_OFF_A_calc") #! Field("PPS:CLTS:5:MERGE_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:5:MERGE_OFF_A_calc.INPA") #! Link("PPS:CLTS:5:MERGE_OFF_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb14.VAL") #! Field("PPS:CLTS:5:MERGE_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:5:MERGE_OFF_A_calc.INPB") #! Field("PPS:CLTS:5:MERGE_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:5:MERGE_OFF_A_calc.OUT") #! Link("PPS:CLTS:5:MERGE_OFF_A_calc.OUT","PPS:CLTS:5:MERGE_OFF_A.VAL") #! Record("PPS:CLTS:5:MERGE_OFF_A",500,20,0,0,"PPS:CLTS:5:MERGE_OFF_A") #! Field("PPS:CLTS:5:MERGE_OFF_A.VAL",16777215,1,"PPS:CLTS:5:MERGE_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi13") { field(DESC, "Port ST34_RDA bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 13, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:5:MERGE_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:MERGE_ON_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:MERGE_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:MERGE_ON_A") { field(DESC, "CL-Merge ON") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb13",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb13") #! Field("PLC:BSY0:PP07:ST34_RDAb13.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb13.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb13.FLNK","PPS:CLTS:5:MERGE_ON_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb13.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb13.VAL") #! Record("PPS:CLTS:5:MERGE_ON_A_calc",260,18,0,1,"PPS:CLTS:5:MERGE_ON_A_calc") #! Field("PPS:CLTS:5:MERGE_ON_A_calc.INPA",16777215,0,"PPS:CLTS:5:MERGE_ON_A_calc.INPA") #! Link("PPS:CLTS:5:MERGE_ON_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb13.VAL") #! Field("PPS:CLTS:5:MERGE_ON_A_calc.INPB",16777215,1,"PPS:CLTS:5:MERGE_ON_A_calc.INPB") #! Field("PPS:CLTS:5:MERGE_ON_A_calc.OUT",16777215,1,"PPS:CLTS:5:MERGE_ON_A_calc.OUT") #! Link("PPS:CLTS:5:MERGE_ON_A_calc.OUT","PPS:CLTS:5:MERGE_ON_A.VAL") #! Record("PPS:CLTS:5:MERGE_ON_A",500,20,0,0,"PPS:CLTS:5:MERGE_ON_A") #! Field("PPS:CLTS:5:MERGE_ON_A.VAL",16777215,1,"PPS:CLTS:5:MERGE_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi12") { field(DESC, "Port ST34_RDA bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 12, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:ADMIN_EN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:ADMIN_EN_A") { field(DESC, "SXR Admn Enable Key (ANR & NEH)(STCLTS)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb12",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb12") #! Field("PLC:BSY0:PP07:ST34_RDAb12.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb12.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb12.FLNK","PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb12.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb12.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb12.VAL") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_A_calc.OUT","PPS:BSYS:1:STCLTS:ADMIN_EN_A.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_A",500,20,0,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_A") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi11") { field(DESC, "Port ST34_RDA bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 11, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34A:IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi11 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:IN_A") { field(DESC, "ST34A IN LS") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb11",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb11") #! Field("PLC:BSY0:PP07:ST34_RDAb11.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb11.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb11.FLNK","PPS:BSYS:1:ST34A:IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb11.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb11.VAL") #! Record("PPS:BSYS:1:ST34A:IN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34A:IN_A_calc") #! Field("PPS:BSYS:1:ST34A:IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:IN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34A:IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb11.VAL") #! Field("PPS:BSYS:1:ST34A:IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:IN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34A:IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:IN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34A:IN_A_calc.OUT","PPS:BSYS:1:ST34A:IN_A.VAL") #! Record("PPS:BSYS:1:ST34A:IN_A",500,20,0,0,"PPS:BSYS:1:ST34A:IN_A") #! Field("PPS:BSYS:1:ST34A:IN_A.VAL",16777215,1,"PPS:BSYS:1:ST34A:IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi10") { field(DESC, "Port ST34_RDA bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 10, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34A:OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:OUT_A") { field(DESC, "ST34A OUT LS") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb10",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb10") #! Field("PLC:BSY0:PP07:ST34_RDAb10.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb10.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb10.FLNK","PPS:BSYS:1:ST34A:OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb10.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb10.VAL") #! Record("PPS:BSYS:1:ST34A:OUT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34A:OUT_A_calc") #! Field("PPS:BSYS:1:ST34A:OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:OUT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34A:OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb10.VAL") #! Field("PPS:BSYS:1:ST34A:OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:OUT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34A:OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:OUT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34A:OUT_A_calc.OUT","PPS:BSYS:1:ST34A:OUT_A.VAL") #! Record("PPS:BSYS:1:ST34A:OUT_A",500,20,0,0,"PPS:BSYS:1:ST34A:OUT_A") #! Field("PPS:BSYS:1:ST34A:OUT_A.VAL",16777215,1,"PPS:BSYS:1:ST34A:OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi9") { field(DESC, "Port ST34_RDA bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 9, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34B:IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:IN_A") { field(DESC, "ST34B IN LS") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb9",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb9") #! Field("PLC:BSY0:PP07:ST34_RDAb9.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb9.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb9.FLNK","PPS:BSYS:1:ST34B:IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb9.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb9.VAL") #! Record("PPS:BSYS:1:ST34B:IN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34B:IN_A_calc") #! Field("PPS:BSYS:1:ST34B:IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:IN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34B:IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb9.VAL") #! Field("PPS:BSYS:1:ST34B:IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:IN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34B:IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:IN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34B:IN_A_calc.OUT","PPS:BSYS:1:ST34B:IN_A.VAL") #! Record("PPS:BSYS:1:ST34B:IN_A",500,20,0,0,"PPS:BSYS:1:ST34B:IN_A") #! Field("PPS:BSYS:1:ST34B:IN_A.VAL",16777215,1,"PPS:BSYS:1:ST34B:IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi8") { field(DESC, "Port ST34_RDA bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 8, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34B:OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:OUT_A") { field(DESC, "ST34B OUT LS") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb8",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb8") #! Field("PLC:BSY0:PP07:ST34_RDAb8.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb8.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb8.FLNK","PPS:BSYS:1:ST34B:OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb8.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb8.VAL") #! Record("PPS:BSYS:1:ST34B:OUT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34B:OUT_A_calc") #! Field("PPS:BSYS:1:ST34B:OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:OUT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34B:OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb8.VAL") #! Field("PPS:BSYS:1:ST34B:OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:OUT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34B:OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:OUT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34B:OUT_A_calc.OUT","PPS:BSYS:1:ST34B:OUT_A.VAL") #! Record("PPS:BSYS:1:ST34B:OUT_A",500,20,0,0,"PPS:BSYS:1:ST34B:OUT_A") #! Field("PPS:BSYS:1:ST34B:OUT_A.VAL",16777215,1,"PPS:BSYS:1:ST34B:OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi23") { field(DESC, "Port ST34_RDA bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 23, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:STCLTS:IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:IN_A") { field(DESC, "STP-CLTS IN LS") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb23",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb23") #! Field("PLC:BSY0:PP07:ST34_RDAb23.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb23.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb23.FLNK","PPS:BSYS:1:STCLTS:IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb23.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb23.VAL") #! Record("PPS:BSYS:1:STCLTS:IN_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:IN_A_calc") #! Field("PPS:BSYS:1:STCLTS:IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:IN_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb23.VAL") #! Field("PPS:BSYS:1:STCLTS:IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:IN_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:IN_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:IN_A_calc.OUT","PPS:BSYS:1:STCLTS:IN_A.VAL") #! Record("PPS:BSYS:1:STCLTS:IN_A",500,20,0,0,"PPS:BSYS:1:STCLTS:IN_A") #! Field("PPS:BSYS:1:STCLTS:IN_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi22") { field(DESC, "Port ST34_RDA bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 22, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:STCLTS:OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:OUT_A") { field(DESC, "STP-CLTS OUT LS") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb22",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb22") #! Field("PLC:BSY0:PP07:ST34_RDAb22.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb22.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb22.FLNK","PPS:BSYS:1:STCLTS:OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb22.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb22.VAL") #! Record("PPS:BSYS:1:STCLTS:OUT_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:OUT_A_calc") #! Field("PPS:BSYS:1:STCLTS:OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:OUT_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb22.VAL") #! Field("PPS:BSYS:1:STCLTS:OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:OUT_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:OUT_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:OUT_A_calc.OUT","PPS:BSYS:1:STCLTS:OUT_A.VAL") #! Record("PPS:BSYS:1:STCLTS:OUT_A",500,20,0,0,"PPS:BSYS:1:STCLTS:OUT_A") #! Field("PPS:BSYS:1:STCLTS:OUT_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi21") { field(DESC, "Port ST34_RDA bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 21, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34:SR_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_IN_A") { field(DESC, "Safety Relay Feedback - STP34 IN") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb21",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb21") #! Field("PLC:BSY0:PP07:ST34_RDAb21.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb21.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb21.FLNK","PPS:BSYS:1:ST34:SR_IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb21.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb21.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_IN_A_calc") #! Field("PPS:BSYS:1:ST34:SR_IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_IN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb21.VAL") #! Field("PPS:BSYS:1:ST34:SR_IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_IN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_IN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_IN_A_calc.OUT","PPS:BSYS:1:ST34:SR_IN_A.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_A",500,20,0,0,"PPS:BSYS:1:ST34:SR_IN_A") #! Field("PPS:BSYS:1:ST34:SR_IN_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi20") { field(DESC, "Port ST34_RDA bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 20, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34:SR_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_OUT_A") { field(DESC, "Safety Relay Feedback - STP34 OUT") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb20",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb20") #! Field("PLC:BSY0:PP07:ST34_RDAb20.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb20.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb20.FLNK","PPS:BSYS:1:ST34:SR_OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb20.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb20.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_OUT_A_calc") #! Field("PPS:BSYS:1:ST34:SR_OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_OUT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb20.VAL") #! Field("PPS:BSYS:1:ST34:SR_OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_OUT_A_calc.OUT","PPS:BSYS:1:ST34:SR_OUT_A.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_A",500,20,0,0,"PPS:BSYS:1:ST34:SR_OUT_A") #! Field("PPS:BSYS:1:ST34:SR_OUT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi19") { field(DESC, "Port ST34_RDA bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 19, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:ST34:TEST_MODE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:TEST_MODE_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi19 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:TEST_MODE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:TEST_MODE_A") { field(DESC, "Test Mode Keyswitch status") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb19",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb19") #! Field("PLC:BSY0:PP07:ST34_RDAb19.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb19.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb19.FLNK","PPS:BSYS:1:ST34:TEST_MODE_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb19.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb19.VAL") #! Record("PPS:BSYS:1:ST34:TEST_MODE_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:TEST_MODE_A_calc") #! Field("PPS:BSYS:1:ST34:TEST_MODE_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:TEST_MODE_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:TEST_MODE_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb19.VAL") #! Field("PPS:BSYS:1:ST34:TEST_MODE_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:TEST_MODE_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:TEST_MODE_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:TEST_MODE_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:TEST_MODE_A_calc.OUT","PPS:BSYS:1:ST34:TEST_MODE_A.VAL") #! Record("PPS:BSYS:1:ST34:TEST_MODE_A",500,20,0,0,"PPS:BSYS:1:ST34:TEST_MODE_A") #! Field("PPS:BSYS:1:ST34:TEST_MODE_A.VAL",16777215,1,"PPS:BSYS:1:ST34:TEST_MODE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi18") { field(DESC, "Port ST34_RDA bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 18, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:PLC5:STP_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:PLC5:STP_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi18 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:PLC5:STP_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:PLC5:STP_ENABLE_A") { field(DESC, "ST34/CLTS Stopper Set Enable Keyswitch") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb18",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb18") #! Field("PLC:BSY0:PP07:ST34_RDAb18.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb18.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb18.FLNK","PPS:BSYS:1:PLC5:STP_ENABLE_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb18.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb18.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_A_calc",260,18,0,1,"PPS:BSYS:1:PLC5:STP_ENABLE_A_calc") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.INPA",16777215,0,"PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.INPA") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb18.VAL") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.INPB",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.INPB") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.OUT",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.OUT") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_A_calc.OUT","PPS:BSYS:1:PLC5:STP_ENABLE_A.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_A",500,20,0,0,"PPS:BSYS:1:PLC5:STP_ENABLE_A") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_A.VAL",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi17") { field(DESC, "Port ST34_RDA bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 17, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT17_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT17_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi17 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT17_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT17_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb17",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb17") #! Field("PLC:BSY0:PP07:ST34_RDAb17.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb17.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb17.FLNK","PPS:BSYS:1:ST34:BIT17_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb17.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb17.VAL") #! Record("PPS:BSYS:1:ST34:BIT17_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT17_A_calc") #! Field("PPS:BSYS:1:ST34:BIT17_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT17_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT17_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb17.VAL") #! Field("PPS:BSYS:1:ST34:BIT17_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT17_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT17_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT17_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT17_A_calc.OUT","PPS:BSYS:1:ST34:BIT17_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT17_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT17_A") #! Field("PPS:BSYS:1:ST34:BIT17_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT17_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi16") { field(DESC, "Port ST34_RDA bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 16, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:BSYS:1:ST34:INTLK_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:INTLK_IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi16 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:INTLK_IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:INTLK_IN_A") { field(DESC, "STP-34 Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb16",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb16") #! Field("PLC:BSY0:PP07:ST34_RDAb16.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb16.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb16.FLNK","PPS:BSYS:1:ST34:INTLK_IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb16.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb16.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:INTLK_IN_A_calc") #! Field("PPS:BSYS:1:ST34:INTLK_IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:INTLK_IN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:INTLK_IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb16.VAL") #! Field("PPS:BSYS:1:ST34:INTLK_IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:INTLK_IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:INTLK_IN_A_calc.OUT","PPS:BSYS:1:ST34:INTLK_IN_A.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_A",500,20,0,0,"PPS:BSYS:1:ST34:INTLK_IN_A") #! Field("PPS:BSYS:1:ST34:INTLK_IN_A.VAL",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi95") { field(DESC, "Port ST34_RDA bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 95, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:BSYS:1:STCLTS:INTLK_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:INTLK_IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi95 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:INTLK_IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:INTLK_IN_A") { field(DESC, "STP-CLTS Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb95",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb95") #! Field("PLC:BSY0:PP07:ST34_RDAb95.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb95.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb95.FLNK","PPS:BSYS:1:STCLTS:INTLK_IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb95.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb95.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:INTLK_IN_A_calc") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb95.VAL") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_A_calc.OUT","PPS:BSYS:1:STCLTS:INTLK_IN_A.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_A",500,20,0,0,"PPS:BSYS:1:STCLTS:INTLK_IN_A") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi94") { field(DESC, "Port ST34_RDA bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 94, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_INP_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi94 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_INP_A") { field(DESC, "Heartbeat IN from oppo. chain") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb94",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb94") #! Field("PLC:BSY0:PP07:ST34_RDAb94.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb94.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb94.FLNK","PPS:BSYS:1:ST34:HRTBT_INP_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb94.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb94.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_INP_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_INP_A_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_INP_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_INP_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb94.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_INP_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_INP_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_INP_A_calc.OUT","PPS:BSYS:1:ST34:HRTBT_INP_A.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_INP_A",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_INP_A") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_A.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi93") { field(DESC, "Port ST34_RDA bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 93, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT93_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT93_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi93 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT93_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT93_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb93",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb93") #! Field("PLC:BSY0:PP07:ST34_RDAb93.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb93.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb93.FLNK","PPS:BSYS:1:ST34:BIT93_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb93.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb93.VAL") #! Record("PPS:BSYS:1:ST34:BIT93_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT93_A_calc") #! Field("PPS:BSYS:1:ST34:BIT93_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT93_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT93_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb93.VAL") #! Field("PPS:BSYS:1:ST34:BIT93_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT93_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT93_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT93_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT93_A_calc.OUT","PPS:BSYS:1:ST34:BIT93_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT93_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT93_A") #! Field("PPS:BSYS:1:ST34:BIT93_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT93_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi92") { field(DESC, "Port ST34_RDA bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 92, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi92 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A") { field(DESC, "BTH not in Test Mode") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb92",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb92") #! Field("PLC:BSY0:PP07:ST34_RDAb92.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb92.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb92.FLNK","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb92.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb92.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc",260,18,0,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.INPA",16777215,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.INPA") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb92.VAL") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.INPB",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.INPB") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.OUT",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.OUT") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A_calc.OUT","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A",500,20,0,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A.VAL",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi91") { field(DESC, "Port ST34_RDA bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HWALRMWARN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HWALRMWARN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi91 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HWALRMWARN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HWALRMWARN_A") { field(DESC, "ACR Hardware alarm/warning") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb91",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb91") #! Field("PLC:BSY0:PP07:ST34_RDAb91.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb91.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb91.FLNK","PPS:BSYS:1:ST34:HWALRMWARN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb91.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb91.VAL") #! Record("PPS:BSYS:1:ST34:HWALRMWARN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:HWALRMWARN_A_calc") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HWALRMWARN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:HWALRMWARN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb91.VAL") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HWALRMWARN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HWALRMWARN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:HWALRMWARN_A_calc.OUT","PPS:BSYS:1:ST34:HWALRMWARN_A.VAL") #! Record("PPS:BSYS:1:ST34:HWALRMWARN_A",500,20,0,0,"PPS:BSYS:1:ST34:HWALRMWARN_A") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_A.VAL",16777215,1,"PPS:BSYS:1:ST34:HWALRMWARN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi90") { field(DESC, "Port ST34_RDA bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_OUTP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_OUTP_A") { field(DESC, "Heartbeat Out (to opposite chain)") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb90",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb90") #! Field("PLC:BSY0:PP07:ST34_RDAb90.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb90.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb90.FLNK","PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb90.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb90.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb90.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_OUTP_A_calc.OUT","PPS:BSYS:1:ST34:HRTBT_OUTP_A.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OUTP_A",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_OUTP_A") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_A.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi89") { field(DESC, "Port ST34_RDA bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 89, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34:SUM_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SUM_IN_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SUM_IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SUM_IN_A") { field(DESC, "STP-34 Summary IN to relay") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb89",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb89") #! Field("PLC:BSY0:PP07:ST34_RDAb89.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb89.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb89.FLNK","PPS:BSYS:1:ST34:SUM_IN_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb89.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb89.VAL") #! Record("PPS:BSYS:1:ST34:SUM_IN_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SUM_IN_A_calc") #! Field("PPS:BSYS:1:ST34:SUM_IN_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SUM_IN_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SUM_IN_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb89.VAL") #! Field("PPS:BSYS:1:ST34:SUM_IN_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SUM_IN_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SUM_IN_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SUM_IN_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SUM_IN_A_calc.OUT","PPS:BSYS:1:ST34:SUM_IN_A.VAL") #! Record("PPS:BSYS:1:ST34:SUM_IN_A",500,20,0,0,"PPS:BSYS:1:ST34:SUM_IN_A") #! Field("PPS:BSYS:1:ST34:SUM_IN_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SUM_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi88") { field(DESC, "Port ST34_RDA bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 88, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34:SUM_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SUM_OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SUM_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SUM_OUT_A") { field(DESC, "STP-34 Summary OUT to relay") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb88",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb88") #! Field("PLC:BSY0:PP07:ST34_RDAb88.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb88.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb88.FLNK","PPS:BSYS:1:ST34:SUM_OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb88.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb88.VAL") #! Record("PPS:BSYS:1:ST34:SUM_OUT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SUM_OUT_A_calc") #! Field("PPS:BSYS:1:ST34:SUM_OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SUM_OUT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SUM_OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb88.VAL") #! Field("PPS:BSYS:1:ST34:SUM_OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SUM_OUT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SUM_OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SUM_OUT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SUM_OUT_A_calc.OUT","PPS:BSYS:1:ST34:SUM_OUT_A.VAL") #! Record("PPS:BSYS:1:ST34:SUM_OUT_A",500,20,0,0,"PPS:BSYS:1:ST34:SUM_OUT_A") #! Field("PPS:BSYS:1:ST34:SUM_OUT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SUM_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi103") { field(DESC, "Port ST34_RDA bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 103, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:ST34:CROSS_TEST_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:CROSS_TEST_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:CROSS_TEST_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:CROSS_TEST_A") { field(DESC, "Cross-interlock testswitch, test mode") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb103",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb103") #! Field("PLC:BSY0:PP07:ST34_RDAb103.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb103.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb103.FLNK","PPS:BSYS:1:ST34:CROSS_TEST_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb103.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb103.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_TEST_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:CROSS_TEST_A_calc") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:CROSS_TEST_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:CROSS_TEST_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb103.VAL") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:CROSS_TEST_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:CROSS_TEST_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:CROSS_TEST_A_calc.OUT","PPS:BSYS:1:ST34:CROSS_TEST_A.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_TEST_A",500,20,0,0,"PPS:BSYS:1:ST34:CROSS_TEST_A") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_A.VAL",16777215,1,"PPS:BSYS:1:ST34:CROSS_TEST_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi102") { field(DESC, "Port ST34_RDA bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 102, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:ST34:CROSS_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:CROSS_INTLK_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:CROSS_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:CROSS_INTLK_A") { field(DESC, "Cross-intlk testswitch, opposite chain") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb102",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb102") #! Field("PLC:BSY0:PP07:ST34_RDAb102.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb102.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb102.FLNK","PPS:BSYS:1:ST34:CROSS_INTLK_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb102.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb102.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_INTLK_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:CROSS_INTLK_A_calc") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb102.VAL") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:CROSS_INTLK_A_calc.OUT","PPS:BSYS:1:ST34:CROSS_INTLK_A.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_INTLK_A",500,20,0,0,"PPS:BSYS:1:ST34:CROSS_INTLK_A") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_A.VAL",16777215,1,"PPS:BSYS:1:ST34:CROSS_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi101") { field(DESC, "Port ST34_RDA bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 101, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:BSYS:1:ST34:PERMITTED_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:PERMITTED_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:PERMITTED_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:PERMITTED_A") { field(DESC, "STP-34 Stopper Set Permit") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb101",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb101") #! Field("PLC:BSY0:PP07:ST34_RDAb101.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb101.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb101.FLNK","PPS:BSYS:1:ST34:PERMITTED_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb101.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb101.VAL") #! Record("PPS:BSYS:1:ST34:PERMITTED_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:PERMITTED_A_calc") #! Field("PPS:BSYS:1:ST34:PERMITTED_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:PERMITTED_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:PERMITTED_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb101.VAL") #! Field("PPS:BSYS:1:ST34:PERMITTED_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:PERMITTED_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:PERMITTED_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:PERMITTED_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:PERMITTED_A_calc.OUT","PPS:BSYS:1:ST34:PERMITTED_A.VAL") #! Record("PPS:BSYS:1:ST34:PERMITTED_A",500,20,0,0,"PPS:BSYS:1:ST34:PERMITTED_A") #! Field("PPS:BSYS:1:ST34:PERMITTED_A.VAL",16777215,1,"PPS:BSYS:1:ST34:PERMITTED_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi100") { field(DESC, "Port ST34_RDA bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 100, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:BSYS:1:STCLTS:PERMITTED_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:PERMITTED_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:PERMITTED_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:PERMITTED_A") { field(DESC, "STP-CLTS Stopper Permit") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb100",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb100") #! Field("PLC:BSY0:PP07:ST34_RDAb100.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb100.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb100.FLNK","PPS:BSYS:1:STCLTS:PERMITTED_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb100.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb100.VAL") #! Record("PPS:BSYS:1:STCLTS:PERMITTED_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:PERMITTED_A_calc") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:PERMITTED_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:PERMITTED_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb100.VAL") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:PERMITTED_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:PERMITTED_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:PERMITTED_A_calc.OUT","PPS:BSYS:1:STCLTS:PERMITTED_A.VAL") #! Record("PPS:BSYS:1:STCLTS:PERMITTED_A",500,20,0,0,"PPS:BSYS:1:STCLTS:PERMITTED_A") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:PERMITTED_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi99") { field(DESC, "Port ST34_RDA bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi99 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A") { field(DESC, "BCS Ok from PLC5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb99",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb99") #! Field("PLC:BSY0:PP07:ST34_RDAb99.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb99.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb99.FLNK","PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb99.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb99.VAL") #! Record("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb99.VAL") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A_calc.OUT","PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A.VAL") #! Record("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A",500,20,0,0,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi98") { field(DESC, "Port ST34_RDA bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 98, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT98_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT98_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi98 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT98_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT98_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb98",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb98") #! Field("PLC:BSY0:PP07:ST34_RDAb98.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb98.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb98.FLNK","PPS:BSYS:1:ST34:BIT98_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb98.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb98.VAL") #! Record("PPS:BSYS:1:ST34:BIT98_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT98_A_calc") #! Field("PPS:BSYS:1:ST34:BIT98_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT98_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT98_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb98.VAL") #! Field("PPS:BSYS:1:ST34:BIT98_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT98_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT98_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT98_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT98_A_calc.OUT","PPS:BSYS:1:ST34:BIT98_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT98_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT98_A") #! Field("PPS:BSYS:1:ST34:BIT98_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT98_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi97") { field(DESC, "Port ST34_RDA bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 97, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:SOLENOID_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:SOLENOID_OUT_A") { field(DESC, "STPR34A solenoid driver output") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb97",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb97") #! Field("PLC:BSY0:PP07:ST34_RDAb97.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb97.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb97.FLNK","PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb97.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb97.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb97.VAL") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34A:SOLENOID_OUT_A_calc.OUT","PPS:BSYS:1:ST34A:SOLENOID_OUT_A.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_OUT_A",500,20,0,0,"PPS:BSYS:1:ST34A:SOLENOID_OUT_A") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_A.VAL",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi96") { field(DESC, "Port ST34_RDA bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 96, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi96 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:SOLENOID_RET_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:SOLENOID_RET_A") { field(DESC, "STPR34A solenoid driver output (RET)") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb96",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb96") #! Field("PLC:BSY0:PP07:ST34_RDAb96.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb96.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb96.FLNK","PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb96.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb96.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc",260,18,0,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.INPA") #! Link("PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb96.VAL") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.INPB") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.OUT") #! Link("PPS:BSYS:1:ST34A:SOLENOID_RET_A_calc.OUT","PPS:BSYS:1:ST34A:SOLENOID_RET_A.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_RET_A",500,20,0,0,"PPS:BSYS:1:ST34A:SOLENOID_RET_A") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_A.VAL",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi111") { field(DESC, "Port ST34_RDA bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 111, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:SOLENOID_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:SOLENOID_OUT_A") { field(DESC, "STPR34B solenoid driver output") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb111",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb111") #! Field("PLC:BSY0:PP07:ST34_RDAb111.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb111.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb111.FLNK","PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb111.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb111.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb111.VAL") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34B:SOLENOID_OUT_A_calc.OUT","PPS:BSYS:1:ST34B:SOLENOID_OUT_A.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_OUT_A",500,20,0,0,"PPS:BSYS:1:ST34B:SOLENOID_OUT_A") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_A.VAL",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi110") { field(DESC, "Port ST34_RDA bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 110, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:SOLENOID_RET_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:SOLENOID_RET_A") { field(DESC, "STPR34B solenoid driver output (RET)") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb110",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb110") #! Field("PLC:BSY0:PP07:ST34_RDAb110.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb110.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb110.FLNK","PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb110.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb110.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc",260,18,0,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.INPA") #! Link("PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb110.VAL") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.INPB") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.OUT") #! Link("PPS:BSYS:1:ST34B:SOLENOID_RET_A_calc.OUT","PPS:BSYS:1:ST34B:SOLENOID_RET_A.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_RET_A",500,20,0,0,"PPS:BSYS:1:ST34B:SOLENOID_RET_A") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_A.VAL",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi109") { field(DESC, "Port ST34_RDA bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 109, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_A") { field(DESC, "STP-CLTS solenoid driver output") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb109",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb109") #! Field("PLC:BSY0:PP07:ST34_RDAb109.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb109.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb109.FLNK","PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb109.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb109.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb109.VAL") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A_calc.OUT","PPS:BSYS:1:STCLTS:SOLENOID_OUT_A.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A",500,20,0,0,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_A") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi108") { field(DESC, "Port ST34_RDA bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 108, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:SOLENOID_RET_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:SOLENOID_RET_A") { field(DESC, "STP-CLTS solenoid driver output (RET)") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb108",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb108") #! Field("PLC:BSY0:PP07:ST34_RDAb108.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb108.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb108.FLNK","PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb108.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb108.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb108.VAL") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_RET_A_calc.OUT","PPS:BSYS:1:STCLTS:SOLENOID_RET_A.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_RET_A",500,20,0,0,"PPS:BSYS:1:STCLTS:SOLENOID_RET_A") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi107") { field(DESC, "Port ST34_RDA bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 107, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT107_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT107_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT107_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT107_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb107",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb107") #! Field("PLC:BSY0:PP07:ST34_RDAb107.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb107.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb107.FLNK","PPS:BSYS:1:ST34:BIT107_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb107.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb107.VAL") #! Record("PPS:BSYS:1:ST34:BIT107_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT107_A_calc") #! Field("PPS:BSYS:1:ST34:BIT107_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT107_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT107_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb107.VAL") #! Field("PPS:BSYS:1:ST34:BIT107_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT107_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT107_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT107_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT107_A_calc.OUT","PPS:BSYS:1:ST34:BIT107_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT107_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT107_A") #! Field("PPS:BSYS:1:ST34:BIT107_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT107_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi106") { field(DESC, "Port ST34_RDA bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 106, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT106_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT106_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT106_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT106_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb106",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb106") #! Field("PLC:BSY0:PP07:ST34_RDAb106.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb106.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb106.FLNK","PPS:BSYS:1:ST34:BIT106_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb106.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb106.VAL") #! Record("PPS:BSYS:1:ST34:BIT106_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT106_A_calc") #! Field("PPS:BSYS:1:ST34:BIT106_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT106_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT106_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb106.VAL") #! Field("PPS:BSYS:1:ST34:BIT106_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT106_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT106_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT106_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT106_A_calc.OUT","PPS:BSYS:1:ST34:BIT106_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT106_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT106_A") #! Field("PPS:BSYS:1:ST34:BIT106_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT106_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi105") { field(DESC, "Port ST34_RDA bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 105, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A") { field(DESC, "LAT LCLS Secure") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb105",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb105") #! Field("PLC:BSY0:PP07:ST34_RDAb105.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb105.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb105.FLNK","PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb105.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb105.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb105.VAL") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A_calc.OUT","PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi104") { field(DESC, "Port ST34_RDA bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 104, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A") { field(DESC, "LAT BSOICS Group-C OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb104",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb104") #! Field("PLC:BSY0:PP07:ST34_RDAb104.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb104.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb104.FLNK","PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb104.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb104.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb104.VAL") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A_calc.OUT","PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi119") { field(DESC, "Port ST34_RDA bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 119, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_A") { field(DESC, "LAT STP-34 Admin Enable") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb119",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb119") #! Field("PLC:BSY0:PP07:ST34_RDAb119.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb119.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb119.FLNK","PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb119.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb119.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb119.VAL") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A_calc.OUT","PPS:BSYS:1:ST34:ADMIN_EN_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_A") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi118") { field(DESC, "Port ST34_RDA bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 118, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi118 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A") { field(DESC, "LAT STP-CLTS Admin Enable") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb118",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb118") #! Field("PLC:BSY0:PP07:ST34_RDAb118.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb118.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb118.FLNK","PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb118.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb118.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb118.VAL") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A_calc.OUT","PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A",500,20,0,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi117") { field(DESC, "Port ST34_RDA bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 117, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi117 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A") { field(DESC, "LAT PLC5 Panel Stopper Enable Keyswitch") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb117",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb117") #! Field("PLC:BSY0:PP07:ST34_RDAb117.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb117.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb117.FLNK","PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb117.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb117.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb117.VAL") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A_calc.OUT","PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A",500,20,0,0,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A.VAL",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi116") { field(DESC, "Port ST34_RDA bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:INTLK_IN_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:INTLK_IN_LAT_A") { field(DESC, "LAT STP-34 Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb116",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb116") #! Field("PLC:BSY0:PP07:ST34_RDAb116.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb116.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb116.FLNK","PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb116.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb116.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb116.VAL") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:INTLK_IN_LAT_A_calc.OUT","PPS:BSYS:1:ST34:INTLK_IN_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34:INTLK_IN_LAT_A") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi115") { field(DESC, "Port ST34_RDA bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A") { field(DESC, "LAT STP-CLTS Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb115",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb115") #! Field("PLC:BSY0:PP07:ST34_RDAb115.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb115.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb115.FLNK","PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb115.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb115.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb115.VAL") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A_calc.OUT","PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A",500,20,0,0,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi114") { field(DESC, "Port ST34_RDA bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A") { field(DESC, "LAT BTH not in Test Mode") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb114",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb114") #! Field("PLC:BSY0:PP07:ST34_RDAb114.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb114.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb114.FLNK","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb114.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb114.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb114.VAL") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A_calc.OUT","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A",500,20,0,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A.VAL",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi113") { field(DESC, "Port ST34_RDA bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_A") { field(DESC, "LAT Heartbeat OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb113",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb113") #! Field("PLC:BSY0:PP07:ST34_RDAb113.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb113.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb113.FLNK","PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb113.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb113.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb113.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A_calc.OUT","PPS:BSYS:1:ST34:HRTBT_OK_LTH_A.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_A") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_A.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi112") { field(DESC, "Port ST34_RDA bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 112, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi112 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A") { field(DESC, "LAT SX-Kicker/Sep OFF Summary") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb112",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb112") #! Field("PLC:BSY0:PP07:ST34_RDAb112.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb112.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb112.FLNK","PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb112.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb112.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc",260,18,0,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.INPA",16777215,0,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.INPA") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb112.VAL") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.INPB",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.INPB") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.OUT",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.OUT") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A_calc.OUT","PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A",500,20,0,0,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A.VAL",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi127") { field(DESC, "Port ST34_RDA bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 127, 1, 1)") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A") { field(DESC, "Heartbeat OK") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb127",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb127") #! Field("PLC:BSY0:PP07:ST34_RDAb127.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb127.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb127.FLNK","PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb127.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb127.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb127.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A_calc.OUT","PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi126") { field(DESC, "Port ST34_RDA bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 126, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT126_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT126_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi126 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT126_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT126_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb126",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb126") #! Field("PLC:BSY0:PP07:ST34_RDAb126.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb126.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb126.FLNK","PPS:BSYS:1:ST34:BIT126_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb126.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb126.VAL") #! Record("PPS:BSYS:1:ST34:BIT126_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT126_A_calc") #! Field("PPS:BSYS:1:ST34:BIT126_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT126_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT126_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb126.VAL") #! Field("PPS:BSYS:1:ST34:BIT126_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT126_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT126_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT126_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT126_A_calc.OUT","PPS:BSYS:1:ST34:BIT126_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT126_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT126_A") #! Field("PPS:BSYS:1:ST34:BIT126_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT126_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi125") { field(DESC, "Port ST34_RDA bit 125") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 125, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT125_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT125_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi125 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT125_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT125_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb125",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb125") #! Field("PLC:BSY0:PP07:ST34_RDAb125.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb125.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb125.FLNK","PPS:BSYS:1:ST34:BIT125_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb125.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb125.VAL") #! Record("PPS:BSYS:1:ST34:BIT125_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT125_A_calc") #! Field("PPS:BSYS:1:ST34:BIT125_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT125_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT125_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb125.VAL") #! Field("PPS:BSYS:1:ST34:BIT125_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT125_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT125_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT125_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT125_A_calc.OUT","PPS:BSYS:1:ST34:BIT125_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT125_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT125_A") #! Field("PPS:BSYS:1:ST34:BIT125_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT125_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi124") { field(DESC, "Port ST34_RDA bit 124") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 124, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT124_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT124_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi124 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT124_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT124_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb124",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb124") #! Field("PLC:BSY0:PP07:ST34_RDAb124.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb124.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb124.FLNK","PPS:BSYS:1:ST34:BIT124_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb124.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb124.VAL") #! Record("PPS:BSYS:1:ST34:BIT124_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT124_A_calc") #! Field("PPS:BSYS:1:ST34:BIT124_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT124_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT124_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb124.VAL") #! Field("PPS:BSYS:1:ST34:BIT124_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT124_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT124_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT124_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT124_A_calc.OUT","PPS:BSYS:1:ST34:BIT124_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT124_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT124_A") #! Field("PPS:BSYS:1:ST34:BIT124_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT124_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi123") { field(DESC, "Port ST34_RDA bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 123, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34:BIT123_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT123_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT123_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT123_A") { field(DESC, "(spare)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb123",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb123") #! Field("PLC:BSY0:PP07:ST34_RDAb123.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb123.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb123.FLNK","PPS:BSYS:1:ST34:BIT123_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb123.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb123.VAL") #! Record("PPS:BSYS:1:ST34:BIT123_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT123_A_calc") #! Field("PPS:BSYS:1:ST34:BIT123_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT123_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT123_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb123.VAL") #! Field("PPS:BSYS:1:ST34:BIT123_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT123_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT123_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT123_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT123_A_calc.OUT","PPS:BSYS:1:ST34:BIT123_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT123_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT123_A") #! Field("PPS:BSYS:1:ST34:BIT123_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT123_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi122") { field(DESC, "Port ST34_RDA bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 122, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34:BIT122_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT122_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi122 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT122_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT122_A") { field(DESC, "(spare)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb122",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb122") #! Field("PLC:BSY0:PP07:ST34_RDAb122.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb122.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb122.FLNK","PPS:BSYS:1:ST34:BIT122_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb122.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb122.VAL") #! Record("PPS:BSYS:1:ST34:BIT122_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT122_A_calc") #! Field("PPS:BSYS:1:ST34:BIT122_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT122_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT122_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb122.VAL") #! Field("PPS:BSYS:1:ST34:BIT122_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT122_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT122_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT122_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT122_A_calc.OUT","PPS:BSYS:1:ST34:BIT122_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT122_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT122_A") #! Field("PPS:BSYS:1:ST34:BIT122_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT122_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi121") { field(DESC, "Port ST34_RDA bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 121, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYS:1:ST34A:STPR_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:STPR_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:STPR_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:STPR_FAULT_A") { field(DESC, "Stopper Fault STP-34A") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb121",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb121") #! Field("PLC:BSY0:PP07:ST34_RDAb121.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb121.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb121.FLNK","PPS:BSYS:1:ST34A:STPR_FAULT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb121.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb121.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34A:STPR_FAULT_A_calc") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb121.VAL") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_A_calc.OUT","PPS:BSYS:1:ST34A:STPR_FAULT_A.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_A",500,20,0,0,"PPS:BSYS:1:ST34A:STPR_FAULT_A") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_A.VAL",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi120") { field(DESC, "Port ST34_RDA bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 120, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYS:1:ST34B:STPR_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:STPR_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:STPR_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:STPR_FAULT_A") { field(DESC, "Stopper Fault STP-34B") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb120",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb120") #! Field("PLC:BSY0:PP07:ST34_RDAb120.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb120.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb120.FLNK","PPS:BSYS:1:ST34B:STPR_FAULT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb120.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb120.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34B:STPR_FAULT_A_calc") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb120.VAL") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_A_calc.OUT","PPS:BSYS:1:ST34B:STPR_FAULT_A.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_A",500,20,0,0,"PPS:BSYS:1:ST34B:STPR_FAULT_A") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_A.VAL",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi135") { field(DESC, "Port ST34_RDA bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 135, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:STPR_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:STPR_FAULT_A") { field(DESC, "Stopper Fault STP-CLTS") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb135",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb135") #! Field("PLC:BSY0:PP07:ST34_RDAb135.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb135.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb135.FLNK","PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb135.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb135.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb135.VAL") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_A_calc.OUT","PPS:BSYS:1:STCLTS:STPR_FAULT_A.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_A",500,20,0,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_A") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi134") { field(DESC, "Port ST34_RDA bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 134, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT134_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT134_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT134_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT134_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb134",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb134") #! Field("PLC:BSY0:PP07:ST34_RDAb134.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb134.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb134.FLNK","PPS:BSYS:1:ST34:BIT134_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb134.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb134.VAL") #! Record("PPS:BSYS:1:ST34:BIT134_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT134_A_calc") #! Field("PPS:BSYS:1:ST34:BIT134_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT134_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT134_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb134.VAL") #! Field("PPS:BSYS:1:ST34:BIT134_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT134_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT134_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT134_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT134_A_calc.OUT","PPS:BSYS:1:ST34:BIT134_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT134_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT134_A") #! Field("PPS:BSYS:1:ST34:BIT134_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT134_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi133") { field(DESC, "Port ST34_RDA bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 133, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:SR_IN_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_IN_OK_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_IN_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_IN_OK_A") { field(DESC, "Safety Relay STP-34 IN OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb133",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb133") #! Field("PLC:BSY0:PP07:ST34_RDAb133.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb133.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb133.FLNK","PPS:BSYS:1:ST34:SR_IN_OK_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb133.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb133.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_IN_OK_A_calc") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_IN_OK_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb133.VAL") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_A_calc.OUT","PPS:BSYS:1:ST34:SR_IN_OK_A.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_A",500,20,0,0,"PPS:BSYS:1:ST34:SR_IN_OK_A") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi132") { field(DESC, "Port ST34_RDA bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 132, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:SR_OUT_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_OUT_OK_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_OUT_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_OUT_OK_A") { field(DESC, "Safety Relay STP-34 OUT OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb132",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb132") #! Field("PLC:BSY0:PP07:ST34_RDAb132.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb132.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb132.FLNK","PPS:BSYS:1:ST34:SR_OUT_OK_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb132.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb132.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_OUT_OK_A_calc") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb132.VAL") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_A_calc.OUT","PPS:BSYS:1:ST34:SR_OUT_OK_A.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_A",500,20,0,0,"PPS:BSYS:1:ST34:SR_OUT_OK_A") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi131") { field(DESC, "Port ST34_RDA bit 131") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 131, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT131_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT131_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi131 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT131_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT131_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb131",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb131") #! Field("PLC:BSY0:PP07:ST34_RDAb131.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb131.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb131.FLNK","PPS:BSYS:1:ST34:BIT131_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb131.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb131.VAL") #! Record("PPS:BSYS:1:ST34:BIT131_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT131_A_calc") #! Field("PPS:BSYS:1:ST34:BIT131_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT131_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT131_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb131.VAL") #! Field("PPS:BSYS:1:ST34:BIT131_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT131_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT131_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT131_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT131_A_calc.OUT","PPS:BSYS:1:ST34:BIT131_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT131_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT131_A") #! Field("PPS:BSYS:1:ST34:BIT131_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT131_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi130") { field(DESC, "Port ST34_RDA bit 130") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 130, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT130_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT130_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi130 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT130_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT130_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb130",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb130") #! Field("PLC:BSY0:PP07:ST34_RDAb130.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb130.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb130.FLNK","PPS:BSYS:1:ST34:BIT130_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb130.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb130.VAL") #! Record("PPS:BSYS:1:ST34:BIT130_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT130_A_calc") #! Field("PPS:BSYS:1:ST34:BIT130_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT130_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT130_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb130.VAL") #! Field("PPS:BSYS:1:ST34:BIT130_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT130_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT130_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT130_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT130_A_calc.OUT","PPS:BSYS:1:ST34:BIT130_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT130_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT130_A") #! Field("PPS:BSYS:1:ST34:BIT130_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT130_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi129") { field(DESC, "Port ST34_RDA bit 129") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 129, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT129_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT129_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi129 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT129_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT129_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb129",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb129") #! Field("PLC:BSY0:PP07:ST34_RDAb129.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb129.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb129.FLNK","PPS:BSYS:1:ST34:BIT129_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb129.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb129.VAL") #! Record("PPS:BSYS:1:ST34:BIT129_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT129_A_calc") #! Field("PPS:BSYS:1:ST34:BIT129_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT129_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT129_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb129.VAL") #! Field("PPS:BSYS:1:ST34:BIT129_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT129_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT129_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT129_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT129_A_calc.OUT","PPS:BSYS:1:ST34:BIT129_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT129_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT129_A") #! Field("PPS:BSYS:1:ST34:BIT129_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT129_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi128") { field(DESC, "Port ST34_RDA bit 128") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 128, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT128_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT128_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi128 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT128_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT128_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb128",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb128") #! Field("PLC:BSY0:PP07:ST34_RDAb128.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb128.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb128.FLNK","PPS:BSYS:1:ST34:BIT128_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb128.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb128.VAL") #! Record("PPS:BSYS:1:ST34:BIT128_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT128_A_calc") #! Field("PPS:BSYS:1:ST34:BIT128_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT128_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT128_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb128.VAL") #! Field("PPS:BSYS:1:ST34:BIT128_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT128_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT128_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT128_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT128_A_calc.OUT","PPS:BSYS:1:ST34:BIT128_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT128_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT128_A") #! Field("PPS:BSYS:1:ST34:BIT128_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT128_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi143") { field(DESC, "Port ST34_RDA bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 143, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A") { field(DESC, "LAT Stopper Fault STP-34A") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb143",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb143") #! Field("PLC:BSY0:PP07:ST34_RDAb143.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb143.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb143.FLNK","PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb143.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb143.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb143.VAL") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A_calc.OUT","PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi142") { field(DESC, "Port ST34_RDA bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 142, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A") { field(DESC, "LAT Stopper Fault STP-34B") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb142",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb142") #! Field("PLC:BSY0:PP07:ST34_RDAb142.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb142.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb142.FLNK","PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb142.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb142.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb142.VAL") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A_calc.OUT","PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi141") { field(DESC, "Port ST34_RDA bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 141, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A") { field(DESC, "LAT Stopper Fault STP-CLTS") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb141",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb141") #! Field("PLC:BSY0:PP07:ST34_RDAb141.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb141.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb141.FLNK","PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb141.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb141.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb141.VAL") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A_calc.OUT","PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A",500,20,0,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A.VAL",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi140") { field(DESC, "Port ST34_RDA bit 140") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 140, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT140_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT140_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi140 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT140_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT140_A") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb140",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb140") #! Field("PLC:BSY0:PP07:ST34_RDAb140.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb140.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb140.FLNK","PPS:BSYS:1:ST34:BIT140_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb140.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb140.VAL") #! Record("PPS:BSYS:1:ST34:BIT140_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT140_A_calc") #! Field("PPS:BSYS:1:ST34:BIT140_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT140_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT140_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb140.VAL") #! Field("PPS:BSYS:1:ST34:BIT140_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT140_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT140_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT140_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT140_A_calc.OUT","PPS:BSYS:1:ST34:BIT140_A.VAL") #! Record("PPS:BSYS:1:ST34:BIT140_A",500,20,0,0,"PPS:BSYS:1:ST34:BIT140_A") #! Field("PPS:BSYS:1:ST34:BIT140_A.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT140_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi139") { field(DESC, "Port ST34_RDA bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 139, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_A") { field(DESC, "LAT Safety Relay STP-34 IN OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb139",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb139") #! Field("PLC:BSY0:PP07:ST34_RDAb139.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb139.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb139.FLNK","PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb139.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb139.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb139.VAL") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A_calc.OUT","PPS:BSYS:1:ST34:SR_IN_OK_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_A") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP07:Bi138") { field(DESC, "Port ST34_RDA bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc") { field(INPA, "PLC:BSY0:PP07:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP07:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A") { field(DESC, "LAT Safety Relay STP-34 OUT OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP07:ST34_RDAb138",20,19,0,0,"PLC:BSY0:PP07:ST34_RDAb138") #! Field("PLC:BSY0:PP07:ST34_RDAb138.FLNK",16777215,1,"PLC:BSY0:PP07:ST34_RDAb138.FLNK") #! Link("PLC:BSY0:PP07:ST34_RDAb138.FLNK","PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc") #! Field("PLC:BSY0:PP07:ST34_RDAb138.VAL",16777215,0,"PLC:BSY0:PP07:ST34_RDAb138.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.INPA","PLC:BSY0:PP07:ST34_RDAb138.VAL") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A_calc.OUT","PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A",500,20,0,0,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_A.VAL") record(bo, "PPS:BSYS:1:ST34:RESET_INTLK_A") { field(DESC, "ST34_Interlock_Reset_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:PAUSEHB_A") { field(DESC, "ST34_Pause_Heartbeat_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:SET_IN_A") { field(DESC, "Send_ST34_Set_In_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 5, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:SET_OUT_A") { field(DESC, "Send_ST34_Set_Out_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 4, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:STCLTS:SET_IN_A") { field(DESC, "Send_STCLTS_Set_In_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 3, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:STCLTS:SET_OUT_A") { field(DESC, "Send_STCLTS_Set_Out_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 2, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP07:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP07:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP07:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP07:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP07:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP07:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP07:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP07:REQ_SEG CP") field( INPC, "PLC:BSY0:PP07:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP07:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP07:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP07:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP07:REQ_SEG CP") field( INPC, "PLC:BSY0:PP07:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP07:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP07:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP07:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP07:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP07:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP07:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP07:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP07:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP07:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP07:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP07:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP07:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP07:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP07:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP07:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP07:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP07:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP07:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP07:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP07:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP07:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP07:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP07:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP07:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP07:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP07:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP07:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP07:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP07:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP07:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP07:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP07:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP07:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP07:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP07:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP07:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP07:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP07:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP07:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP07:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP07:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP07:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP07:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP07:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP07:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP07:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP07:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP07:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP07:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP07:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP07:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP07:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP07:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP07:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP07:w0") { field(DESC, "ST34 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:w1") { field(DESC, "ST34 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP07:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP07:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP07:w3") { field(DESC, "ST34 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP07:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP07:w3 PP MS") field(INPB, "PLC:BSY0:PP07:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP07:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP07:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP07:w4") { field(DESC, "ST34 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP07:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP07:w4 NPP MS") field(INPB, "PLC:BSY0:PP07:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP07:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP07:w5") { field(DESC, "ST34 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP07:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP07:w5 NPP MS") field(INPB, "PLC:BSY0:PP07:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP07:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP07:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP07:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP07:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP07:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP07:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP07:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP07:w6 NPP MS") field(INPB, "PLC:BSY0:PP07:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP07:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP07:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP07:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP07:w7 NPP MS") field(INPB, "PLC:BSY0:PP07:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP07:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDA, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP07:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP07:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP07:w8 NPP MS") field(INPB, "PLC:BSY0:PP07:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP07:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP07:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP07:OP_HOURS") { field(INPA, "PLC:BSY0:PP07:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP07:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP07:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP07:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP07:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(ST34_RDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP07:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP07:RDHist.PROC") } record(waveform,"PLC:BSY0:PP07:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_RDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP07:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP07:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_RDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP07:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP07:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(ST34_RDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP07:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP07:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP07:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP07:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP07:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP07:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP07:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP07:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP07:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP07:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(ST34_WRTA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP07:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP07:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP07:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WRTA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP07:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP07:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WRTA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP07:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP07:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(ST34_WRTA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP07:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTA 0)READ_OK") field(FLNK,"PLC:BSY0:PP07:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP07:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP07:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP07:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP07:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP07:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP07:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP07:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP07:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(ST34_WDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP07:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP07:WDHist.PROC") } record(waveform,"PLC:BSY0:PP07:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP07:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP07:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP07:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP07:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(ST34_WDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP07:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP07:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP07:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP07:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP07:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP07:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP07:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP07:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP07:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDA 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi7") { field(DESC, "Port ST34_RDB bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:ST34:HW_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HW_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HW_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HW_ENABLE_B") { field(DESC, "HW Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb7",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb7") #! Field("PLC:BSY0:PP08:ST34_RDBb7.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb7.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb7.FLNK","PPS:BSYS:1:ST34:HW_ENABLE_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb7.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb7.VAL") #! Record("PPS:BSYS:1:ST34:HW_ENABLE_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:HW_ENABLE_B_calc") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HW_ENABLE_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:HW_ENABLE_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb7.VAL") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HW_ENABLE_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HW_ENABLE_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:HW_ENABLE_B_calc.OUT","PPS:BSYS:1:ST34:HW_ENABLE_B.VAL") #! Record("PPS:BSYS:1:ST34:HW_ENABLE_B",500,20,0,0,"PPS:BSYS:1:ST34:HW_ENABLE_B") #! Field("PPS:BSYS:1:ST34:HW_ENABLE_B.VAL",16777215,1,"PPS:BSYS:1:ST34:HW_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi6") { field(DESC, "Port ST34_RDB bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 6, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:XINTLK_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:XINTLK_IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:XINTLK_IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:XINTLK_IN_B") { field(DESC, "STP-34 Cross-interlock input") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb6",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb6") #! Field("PLC:BSY0:PP08:ST34_RDBb6.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb6.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb6.FLNK","PPS:BSYS:1:ST34:XINTLK_IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb6.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb6.VAL") #! Record("PPS:BSYS:1:ST34:XINTLK_IN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:XINTLK_IN_B_calc") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:XINTLK_IN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:XINTLK_IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb6.VAL") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:XINTLK_IN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:XINTLK_IN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:XINTLK_IN_B_calc.OUT","PPS:BSYS:1:ST34:XINTLK_IN_B.VAL") #! Record("PPS:BSYS:1:ST34:XINTLK_IN_B",500,20,0,0,"PPS:BSYS:1:ST34:XINTLK_IN_B") #! Field("PPS:BSYS:1:ST34:XINTLK_IN_B.VAL",16777215,1,"PPS:BSYS:1:ST34:XINTLK_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi5") { field(DESC, "Port ST34_RDB bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 5, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:BSYS:1:ST34:LCLS_SECURE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:LCLS_SECURE_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:LCLS_SECURE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:LCLS_SECURE_B") { field(DESC, "LCLS Secure") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb5",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb5") #! Field("PLC:BSY0:PP08:ST34_RDBb5.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb5.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb5.FLNK","PPS:BSYS:1:ST34:LCLS_SECURE_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb5.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb5.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:LCLS_SECURE_B_calc") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb5.VAL") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_B_calc.OUT","PPS:BSYS:1:ST34:LCLS_SECURE_B.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_B",500,20,0,0,"PPS:BSYS:1:ST34:LCLS_SECURE_B") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_B.VAL",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi4") { field(DESC, "Port ST34_RDB bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 4, 1, 1)") field(ZNAM, "Not_OK") field(ONAM, "OK") field(FLNK, "PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi4 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BSOICS_C_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BSOICS_C_OK_B") { field(DESC, "BSOICS Group-C OK") field(ZNAM, "Not_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb4",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb4") #! Field("PLC:BSY0:PP08:ST34_RDBb4.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb4.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb4.FLNK","PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb4.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb4.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb4.VAL") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_B_calc.OUT","PPS:BSYS:1:ST34:BSOICS_C_OK_B.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_B",500,20,0,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_B") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi3") { field(DESC, "Port ST34_RDB bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 3, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:ST34:ADMIN_EN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:ADMIN_EN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi3 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:ADMIN_EN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:ADMIN_EN_B") { field(DESC, "SXR Admn Enable Key (ANR & NEH)(ST34)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb3",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb3") #! Field("PLC:BSY0:PP08:ST34_RDBb3.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb3.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb3.FLNK","PPS:BSYS:1:ST34:ADMIN_EN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb3.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb3.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:ADMIN_EN_B_calc") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:ADMIN_EN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb3.VAL") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_B_calc.OUT","PPS:BSYS:1:ST34:ADMIN_EN_B.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_B",500,20,0,0,"PPS:BSYS:1:ST34:ADMIN_EN_B") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_B.VAL",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi2") { field(DESC, "Port ST34_RDB bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 2, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI30:5:SXR:KICKSEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:5:SXR:KICKSEP_OFF_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:5:SXR:KICKSEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:5:SXR:KICKSEP_OFF_B") { field(DESC, "SX-Kicker/Septum Summary OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb2",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb2") #! Field("PLC:BSY0:PP08:ST34_RDBb2.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb2.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb2.FLNK","PPS:LI30:5:SXR:KICKSEP_OFF_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb2.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb2.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_B_calc",260,18,0,1,"PPS:LI30:5:SXR:KICKSEP_OFF_B_calc") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.INPA",16777215,0,"PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.INPA") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb2.VAL") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.INPB",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.INPB") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.OUT",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.OUT") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_B_calc.OUT","PPS:LI30:5:SXR:KICKSEP_OFF_B.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_B",500,20,0,0,"PPS:LI30:5:SXR:KICKSEP_OFF_B") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_B.VAL",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi1") { field(DESC, "Port ST34_RDB bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 1, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:KICK_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:KICK_OFF_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:KICK_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:KICK_OFF_B") { field(DESC, "CL-Kicker OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb1",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb1") #! Field("PLC:BSY0:PP08:ST34_RDBb1.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb1.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb1.FLNK","PPS:CLTS:5:KICK_OFF_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb1.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb1.VAL") #! Record("PPS:CLTS:5:KICK_OFF_B_calc",260,18,0,1,"PPS:CLTS:5:KICK_OFF_B_calc") #! Field("PPS:CLTS:5:KICK_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:5:KICK_OFF_B_calc.INPA") #! Link("PPS:CLTS:5:KICK_OFF_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb1.VAL") #! Field("PPS:CLTS:5:KICK_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:5:KICK_OFF_B_calc.INPB") #! Field("PPS:CLTS:5:KICK_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:5:KICK_OFF_B_calc.OUT") #! Link("PPS:CLTS:5:KICK_OFF_B_calc.OUT","PPS:CLTS:5:KICK_OFF_B.VAL") #! Record("PPS:CLTS:5:KICK_OFF_B",500,20,0,0,"PPS:CLTS:5:KICK_OFF_B") #! Field("PPS:CLTS:5:KICK_OFF_B.VAL",16777215,1,"PPS:CLTS:5:KICK_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi0") { field(DESC, "Port ST34_RDB bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 0, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:DCBEND_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:DCBEND_OFF_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:DCBEND_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:DCBEND_OFF_B") { field(DESC, "CL-DC OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb0",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb0") #! Field("PLC:BSY0:PP08:ST34_RDBb0.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb0.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb0.FLNK","PPS:CLTS:5:DCBEND_OFF_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb0.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb0.VAL") #! Record("PPS:CLTS:5:DCBEND_OFF_B_calc",260,18,0,1,"PPS:CLTS:5:DCBEND_OFF_B_calc") #! Field("PPS:CLTS:5:DCBEND_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:5:DCBEND_OFF_B_calc.INPA") #! Link("PPS:CLTS:5:DCBEND_OFF_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb0.VAL") #! Field("PPS:CLTS:5:DCBEND_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:5:DCBEND_OFF_B_calc.INPB") #! Field("PPS:CLTS:5:DCBEND_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:5:DCBEND_OFF_B_calc.OUT") #! Link("PPS:CLTS:5:DCBEND_OFF_B_calc.OUT","PPS:CLTS:5:DCBEND_OFF_B.VAL") #! Record("PPS:CLTS:5:DCBEND_OFF_B",500,20,0,0,"PPS:CLTS:5:DCBEND_OFF_B") #! Field("PPS:CLTS:5:DCBEND_OFF_B.VAL",16777215,1,"PPS:CLTS:5:DCBEND_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi15") { field(DESC, "Port ST34_RDB bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 15, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:SEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:SEP_OFF_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:SEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:SEP_OFF_B") { field(DESC, "CL-Septum OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb15",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb15") #! Field("PLC:BSY0:PP08:ST34_RDBb15.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb15.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb15.FLNK","PPS:CLTS:5:SEP_OFF_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb15.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb15.VAL") #! Record("PPS:CLTS:5:SEP_OFF_B_calc",260,18,0,1,"PPS:CLTS:5:SEP_OFF_B_calc") #! Field("PPS:CLTS:5:SEP_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:5:SEP_OFF_B_calc.INPA") #! Link("PPS:CLTS:5:SEP_OFF_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb15.VAL") #! Field("PPS:CLTS:5:SEP_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:5:SEP_OFF_B_calc.INPB") #! Field("PPS:CLTS:5:SEP_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:5:SEP_OFF_B_calc.OUT") #! Link("PPS:CLTS:5:SEP_OFF_B_calc.OUT","PPS:CLTS:5:SEP_OFF_B.VAL") #! Record("PPS:CLTS:5:SEP_OFF_B",500,20,0,0,"PPS:CLTS:5:SEP_OFF_B") #! Field("PPS:CLTS:5:SEP_OFF_B.VAL",16777215,1,"PPS:CLTS:5:SEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi14") { field(DESC, "Port ST34_RDB bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 14, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:5:MERGE_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:MERGE_OFF_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:MERGE_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:MERGE_OFF_B") { field(DESC, "CL-Merge OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb14",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb14") #! Field("PLC:BSY0:PP08:ST34_RDBb14.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb14.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb14.FLNK","PPS:CLTS:5:MERGE_OFF_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb14.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb14.VAL") #! Record("PPS:CLTS:5:MERGE_OFF_B_calc",260,18,0,1,"PPS:CLTS:5:MERGE_OFF_B_calc") #! Field("PPS:CLTS:5:MERGE_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:5:MERGE_OFF_B_calc.INPA") #! Link("PPS:CLTS:5:MERGE_OFF_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb14.VAL") #! Field("PPS:CLTS:5:MERGE_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:5:MERGE_OFF_B_calc.INPB") #! Field("PPS:CLTS:5:MERGE_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:5:MERGE_OFF_B_calc.OUT") #! Link("PPS:CLTS:5:MERGE_OFF_B_calc.OUT","PPS:CLTS:5:MERGE_OFF_B.VAL") #! Record("PPS:CLTS:5:MERGE_OFF_B",500,20,0,0,"PPS:CLTS:5:MERGE_OFF_B") #! Field("PPS:CLTS:5:MERGE_OFF_B.VAL",16777215,1,"PPS:CLTS:5:MERGE_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi13") { field(DESC, "Port ST34_RDB bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 13, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:5:MERGE_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:5:MERGE_ON_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:5:MERGE_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:5:MERGE_ON_B") { field(DESC, "CL-Merge ON") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb13",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb13") #! Field("PLC:BSY0:PP08:ST34_RDBb13.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb13.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb13.FLNK","PPS:CLTS:5:MERGE_ON_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb13.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb13.VAL") #! Record("PPS:CLTS:5:MERGE_ON_B_calc",260,18,0,1,"PPS:CLTS:5:MERGE_ON_B_calc") #! Field("PPS:CLTS:5:MERGE_ON_B_calc.INPA",16777215,0,"PPS:CLTS:5:MERGE_ON_B_calc.INPA") #! Link("PPS:CLTS:5:MERGE_ON_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb13.VAL") #! Field("PPS:CLTS:5:MERGE_ON_B_calc.INPB",16777215,1,"PPS:CLTS:5:MERGE_ON_B_calc.INPB") #! Field("PPS:CLTS:5:MERGE_ON_B_calc.OUT",16777215,1,"PPS:CLTS:5:MERGE_ON_B_calc.OUT") #! Link("PPS:CLTS:5:MERGE_ON_B_calc.OUT","PPS:CLTS:5:MERGE_ON_B.VAL") #! Record("PPS:CLTS:5:MERGE_ON_B",500,20,0,0,"PPS:CLTS:5:MERGE_ON_B") #! Field("PPS:CLTS:5:MERGE_ON_B.VAL",16777215,1,"PPS:CLTS:5:MERGE_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi12") { field(DESC, "Port ST34_RDB bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 12, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:ADMIN_EN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:ADMIN_EN_B") { field(DESC, "SXR Admn Enable Key (ANR & NEH)(STCLTS)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb12",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb12") #! Field("PLC:BSY0:PP08:ST34_RDBb12.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb12.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb12.FLNK","PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb12.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb12.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb12.VAL") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_B_calc.OUT","PPS:BSYS:1:STCLTS:ADMIN_EN_B.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_B",500,20,0,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_B") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi11") { field(DESC, "Port ST34_RDB bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 11, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34A:IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi11 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:IN_B") { field(DESC, "ST34A IN LS") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb11",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb11") #! Field("PLC:BSY0:PP08:ST34_RDBb11.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb11.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb11.FLNK","PPS:BSYS:1:ST34A:IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb11.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb11.VAL") #! Record("PPS:BSYS:1:ST34A:IN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34A:IN_B_calc") #! Field("PPS:BSYS:1:ST34A:IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:IN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34A:IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb11.VAL") #! Field("PPS:BSYS:1:ST34A:IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:IN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34A:IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:IN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34A:IN_B_calc.OUT","PPS:BSYS:1:ST34A:IN_B.VAL") #! Record("PPS:BSYS:1:ST34A:IN_B",500,20,0,0,"PPS:BSYS:1:ST34A:IN_B") #! Field("PPS:BSYS:1:ST34A:IN_B.VAL",16777215,1,"PPS:BSYS:1:ST34A:IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi10") { field(DESC, "Port ST34_RDB bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 10, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34A:OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:OUT_B") { field(DESC, "ST34A OUT LS") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb10",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb10") #! Field("PLC:BSY0:PP08:ST34_RDBb10.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb10.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb10.FLNK","PPS:BSYS:1:ST34A:OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb10.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb10.VAL") #! Record("PPS:BSYS:1:ST34A:OUT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34A:OUT_B_calc") #! Field("PPS:BSYS:1:ST34A:OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:OUT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34A:OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb10.VAL") #! Field("PPS:BSYS:1:ST34A:OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:OUT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34A:OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:OUT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34A:OUT_B_calc.OUT","PPS:BSYS:1:ST34A:OUT_B.VAL") #! Record("PPS:BSYS:1:ST34A:OUT_B",500,20,0,0,"PPS:BSYS:1:ST34A:OUT_B") #! Field("PPS:BSYS:1:ST34A:OUT_B.VAL",16777215,1,"PPS:BSYS:1:ST34A:OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi9") { field(DESC, "Port ST34_RDB bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 9, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34B:IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:IN_B") { field(DESC, "ST34B IN LS") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb9",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb9") #! Field("PLC:BSY0:PP08:ST34_RDBb9.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb9.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb9.FLNK","PPS:BSYS:1:ST34B:IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb9.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb9.VAL") #! Record("PPS:BSYS:1:ST34B:IN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34B:IN_B_calc") #! Field("PPS:BSYS:1:ST34B:IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:IN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34B:IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb9.VAL") #! Field("PPS:BSYS:1:ST34B:IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:IN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34B:IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:IN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34B:IN_B_calc.OUT","PPS:BSYS:1:ST34B:IN_B.VAL") #! Record("PPS:BSYS:1:ST34B:IN_B",500,20,0,0,"PPS:BSYS:1:ST34B:IN_B") #! Field("PPS:BSYS:1:ST34B:IN_B.VAL",16777215,1,"PPS:BSYS:1:ST34B:IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi8") { field(DESC, "Port ST34_RDB bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 8, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34B:OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:OUT_B") { field(DESC, "ST34B OUT LS") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb8",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb8") #! Field("PLC:BSY0:PP08:ST34_RDBb8.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb8.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb8.FLNK","PPS:BSYS:1:ST34B:OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb8.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb8.VAL") #! Record("PPS:BSYS:1:ST34B:OUT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34B:OUT_B_calc") #! Field("PPS:BSYS:1:ST34B:OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:OUT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34B:OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb8.VAL") #! Field("PPS:BSYS:1:ST34B:OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:OUT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34B:OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:OUT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34B:OUT_B_calc.OUT","PPS:BSYS:1:ST34B:OUT_B.VAL") #! Record("PPS:BSYS:1:ST34B:OUT_B",500,20,0,0,"PPS:BSYS:1:ST34B:OUT_B") #! Field("PPS:BSYS:1:ST34B:OUT_B.VAL",16777215,1,"PPS:BSYS:1:ST34B:OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi23") { field(DESC, "Port ST34_RDB bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 23, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:STCLTS:IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:IN_B") { field(DESC, "STP-CLTS IN LS") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb23",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb23") #! Field("PLC:BSY0:PP08:ST34_RDBb23.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb23.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb23.FLNK","PPS:BSYS:1:STCLTS:IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb23.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb23.VAL") #! Record("PPS:BSYS:1:STCLTS:IN_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:IN_B_calc") #! Field("PPS:BSYS:1:STCLTS:IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:IN_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb23.VAL") #! Field("PPS:BSYS:1:STCLTS:IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:IN_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:IN_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:IN_B_calc.OUT","PPS:BSYS:1:STCLTS:IN_B.VAL") #! Record("PPS:BSYS:1:STCLTS:IN_B",500,20,0,0,"PPS:BSYS:1:STCLTS:IN_B") #! Field("PPS:BSYS:1:STCLTS:IN_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi22") { field(DESC, "Port ST34_RDB bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 22, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:STCLTS:OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:OUT_B") { field(DESC, "STP-CLTS OUT LS") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb22",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb22") #! Field("PLC:BSY0:PP08:ST34_RDBb22.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb22.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb22.FLNK","PPS:BSYS:1:STCLTS:OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb22.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb22.VAL") #! Record("PPS:BSYS:1:STCLTS:OUT_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:OUT_B_calc") #! Field("PPS:BSYS:1:STCLTS:OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:OUT_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb22.VAL") #! Field("PPS:BSYS:1:STCLTS:OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:OUT_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:OUT_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:OUT_B_calc.OUT","PPS:BSYS:1:STCLTS:OUT_B.VAL") #! Record("PPS:BSYS:1:STCLTS:OUT_B",500,20,0,0,"PPS:BSYS:1:STCLTS:OUT_B") #! Field("PPS:BSYS:1:STCLTS:OUT_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi21") { field(DESC, "Port ST34_RDB bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 21, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34:SR_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_IN_B") { field(DESC, "Safety Relay Feedback - STP34 IN") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb21",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb21") #! Field("PLC:BSY0:PP08:ST34_RDBb21.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb21.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb21.FLNK","PPS:BSYS:1:ST34:SR_IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb21.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb21.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_IN_B_calc") #! Field("PPS:BSYS:1:ST34:SR_IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_IN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb21.VAL") #! Field("PPS:BSYS:1:ST34:SR_IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_IN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_IN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_IN_B_calc.OUT","PPS:BSYS:1:ST34:SR_IN_B.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_B",500,20,0,0,"PPS:BSYS:1:ST34:SR_IN_B") #! Field("PPS:BSYS:1:ST34:SR_IN_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi20") { field(DESC, "Port ST34_RDB bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 20, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34:SR_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_OUT_B") { field(DESC, "Safety Relay Feedback - STP34 OUT") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb20",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb20") #! Field("PLC:BSY0:PP08:ST34_RDBb20.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb20.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb20.FLNK","PPS:BSYS:1:ST34:SR_OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb20.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb20.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_OUT_B_calc") #! Field("PPS:BSYS:1:ST34:SR_OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_OUT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb20.VAL") #! Field("PPS:BSYS:1:ST34:SR_OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_OUT_B_calc.OUT","PPS:BSYS:1:ST34:SR_OUT_B.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_B",500,20,0,0,"PPS:BSYS:1:ST34:SR_OUT_B") #! Field("PPS:BSYS:1:ST34:SR_OUT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi19") { field(DESC, "Port ST34_RDB bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 19, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:ST34:TEST_MODE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:TEST_MODE_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi19 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:TEST_MODE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:TEST_MODE_B") { field(DESC, "Test Mode Keyswitch status") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb19",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb19") #! Field("PLC:BSY0:PP08:ST34_RDBb19.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb19.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb19.FLNK","PPS:BSYS:1:ST34:TEST_MODE_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb19.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb19.VAL") #! Record("PPS:BSYS:1:ST34:TEST_MODE_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:TEST_MODE_B_calc") #! Field("PPS:BSYS:1:ST34:TEST_MODE_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:TEST_MODE_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:TEST_MODE_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb19.VAL") #! Field("PPS:BSYS:1:ST34:TEST_MODE_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:TEST_MODE_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:TEST_MODE_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:TEST_MODE_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:TEST_MODE_B_calc.OUT","PPS:BSYS:1:ST34:TEST_MODE_B.VAL") #! Record("PPS:BSYS:1:ST34:TEST_MODE_B",500,20,0,0,"PPS:BSYS:1:ST34:TEST_MODE_B") #! Field("PPS:BSYS:1:ST34:TEST_MODE_B.VAL",16777215,1,"PPS:BSYS:1:ST34:TEST_MODE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi18") { field(DESC, "Port ST34_RDB bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 18, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYS:1:PLC5:STP_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:PLC5:STP_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi18 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:PLC5:STP_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:PLC5:STP_ENABLE_B") { field(DESC, "ST34/CLTS Stopper Set Enable Keyswitch") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb18",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb18") #! Field("PLC:BSY0:PP08:ST34_RDBb18.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb18.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb18.FLNK","PPS:BSYS:1:PLC5:STP_ENABLE_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb18.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb18.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_B_calc",260,18,0,1,"PPS:BSYS:1:PLC5:STP_ENABLE_B_calc") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.INPA",16777215,0,"PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.INPA") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb18.VAL") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.INPB",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.INPB") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.OUT",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.OUT") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_B_calc.OUT","PPS:BSYS:1:PLC5:STP_ENABLE_B.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_B",500,20,0,0,"PPS:BSYS:1:PLC5:STP_ENABLE_B") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_B.VAL",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi17") { field(DESC, "Port ST34_RDB bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 17, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT17_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT17_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi17 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT17_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT17_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb17",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb17") #! Field("PLC:BSY0:PP08:ST34_RDBb17.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb17.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb17.FLNK","PPS:BSYS:1:ST34:BIT17_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb17.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb17.VAL") #! Record("PPS:BSYS:1:ST34:BIT17_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT17_B_calc") #! Field("PPS:BSYS:1:ST34:BIT17_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT17_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT17_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb17.VAL") #! Field("PPS:BSYS:1:ST34:BIT17_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT17_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT17_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT17_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT17_B_calc.OUT","PPS:BSYS:1:ST34:BIT17_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT17_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT17_B") #! Field("PPS:BSYS:1:ST34:BIT17_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT17_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi16") { field(DESC, "Port ST34_RDB bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 16, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:BSYS:1:ST34:INTLK_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:INTLK_IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi16 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:INTLK_IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:INTLK_IN_B") { field(DESC, "STP-34 Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb16",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb16") #! Field("PLC:BSY0:PP08:ST34_RDBb16.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb16.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb16.FLNK","PPS:BSYS:1:ST34:INTLK_IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb16.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb16.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:INTLK_IN_B_calc") #! Field("PPS:BSYS:1:ST34:INTLK_IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:INTLK_IN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:INTLK_IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb16.VAL") #! Field("PPS:BSYS:1:ST34:INTLK_IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:INTLK_IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:INTLK_IN_B_calc.OUT","PPS:BSYS:1:ST34:INTLK_IN_B.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_B",500,20,0,0,"PPS:BSYS:1:ST34:INTLK_IN_B") #! Field("PPS:BSYS:1:ST34:INTLK_IN_B.VAL",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi95") { field(DESC, "Port ST34_RDB bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 95, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:BSYS:1:STCLTS:INTLK_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:INTLK_IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi95 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:INTLK_IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:INTLK_IN_B") { field(DESC, "STP-CLTS Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb95",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb95") #! Field("PLC:BSY0:PP08:ST34_RDBb95.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb95.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb95.FLNK","PPS:BSYS:1:STCLTS:INTLK_IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb95.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb95.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:INTLK_IN_B_calc") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb95.VAL") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_B_calc.OUT","PPS:BSYS:1:STCLTS:INTLK_IN_B.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_B",500,20,0,0,"PPS:BSYS:1:STCLTS:INTLK_IN_B") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi94") { field(DESC, "Port ST34_RDB bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 94, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_INP_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi94 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_INP_B") { field(DESC, "Heartbeat IN from oppo. chain") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb94",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb94") #! Field("PLC:BSY0:PP08:ST34_RDBb94.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb94.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb94.FLNK","PPS:BSYS:1:ST34:HRTBT_INP_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb94.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb94.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_INP_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_INP_B_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_INP_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_INP_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb94.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_INP_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_INP_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_INP_B_calc.OUT","PPS:BSYS:1:ST34:HRTBT_INP_B.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_INP_B",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_INP_B") #! Field("PPS:BSYS:1:ST34:HRTBT_INP_B.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi93") { field(DESC, "Port ST34_RDB bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 93, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT93_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT93_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi93 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT93_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT93_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb93",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb93") #! Field("PLC:BSY0:PP08:ST34_RDBb93.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb93.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb93.FLNK","PPS:BSYS:1:ST34:BIT93_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb93.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb93.VAL") #! Record("PPS:BSYS:1:ST34:BIT93_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT93_B_calc") #! Field("PPS:BSYS:1:ST34:BIT93_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT93_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT93_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb93.VAL") #! Field("PPS:BSYS:1:ST34:BIT93_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT93_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT93_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT93_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT93_B_calc.OUT","PPS:BSYS:1:ST34:BIT93_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT93_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT93_B") #! Field("PPS:BSYS:1:ST34:BIT93_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT93_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi92") { field(DESC, "Port ST34_RDB bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 92, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi92 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B") { field(DESC, "BTH not in Test Mode") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb92",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb92") #! Field("PLC:BSY0:PP08:ST34_RDBb92.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb92.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb92.FLNK","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb92.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb92.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc",260,18,0,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.INPA",16777215,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.INPA") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb92.VAL") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.INPB",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.INPB") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.OUT",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.OUT") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B_calc.OUT","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B",500,20,0,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B.VAL",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi91") { field(DESC, "Port ST34_RDB bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HWALRMWARN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HWALRMWARN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi91 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HWALRMWARN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HWALRMWARN_B") { field(DESC, "ACR Hardware alarm/warning") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb91",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb91") #! Field("PLC:BSY0:PP08:ST34_RDBb91.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb91.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb91.FLNK","PPS:BSYS:1:ST34:HWALRMWARN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb91.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb91.VAL") #! Record("PPS:BSYS:1:ST34:HWALRMWARN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:HWALRMWARN_B_calc") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HWALRMWARN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:HWALRMWARN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb91.VAL") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HWALRMWARN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HWALRMWARN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:HWALRMWARN_B_calc.OUT","PPS:BSYS:1:ST34:HWALRMWARN_B.VAL") #! Record("PPS:BSYS:1:ST34:HWALRMWARN_B",500,20,0,0,"PPS:BSYS:1:ST34:HWALRMWARN_B") #! Field("PPS:BSYS:1:ST34:HWALRMWARN_B.VAL",16777215,1,"PPS:BSYS:1:ST34:HWALRMWARN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi90") { field(DESC, "Port ST34_RDB bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_OUTP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_OUTP_B") { field(DESC, "Heartbeat Out (to opposite chain)") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb90",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb90") #! Field("PLC:BSY0:PP08:ST34_RDBb90.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb90.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb90.FLNK","PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb90.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb90.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb90.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_OUTP_B_calc.OUT","PPS:BSYS:1:ST34:HRTBT_OUTP_B.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OUTP_B",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_OUTP_B") #! Field("PPS:BSYS:1:ST34:HRTBT_OUTP_B.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OUTP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi89") { field(DESC, "Port ST34_RDB bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 89, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34:SUM_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SUM_IN_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SUM_IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SUM_IN_B") { field(DESC, "STP-34 Summary IN to relay") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb89",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb89") #! Field("PLC:BSY0:PP08:ST34_RDBb89.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb89.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb89.FLNK","PPS:BSYS:1:ST34:SUM_IN_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb89.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb89.VAL") #! Record("PPS:BSYS:1:ST34:SUM_IN_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SUM_IN_B_calc") #! Field("PPS:BSYS:1:ST34:SUM_IN_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SUM_IN_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SUM_IN_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb89.VAL") #! Field("PPS:BSYS:1:ST34:SUM_IN_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SUM_IN_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SUM_IN_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SUM_IN_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SUM_IN_B_calc.OUT","PPS:BSYS:1:ST34:SUM_IN_B.VAL") #! Record("PPS:BSYS:1:ST34:SUM_IN_B",500,20,0,0,"PPS:BSYS:1:ST34:SUM_IN_B") #! Field("PPS:BSYS:1:ST34:SUM_IN_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SUM_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi88") { field(DESC, "Port ST34_RDB bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 88, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34:SUM_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SUM_OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SUM_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SUM_OUT_B") { field(DESC, "STP-34 Summary OUT to relay") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb88",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb88") #! Field("PLC:BSY0:PP08:ST34_RDBb88.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb88.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb88.FLNK","PPS:BSYS:1:ST34:SUM_OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb88.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb88.VAL") #! Record("PPS:BSYS:1:ST34:SUM_OUT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SUM_OUT_B_calc") #! Field("PPS:BSYS:1:ST34:SUM_OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SUM_OUT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SUM_OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb88.VAL") #! Field("PPS:BSYS:1:ST34:SUM_OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SUM_OUT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SUM_OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SUM_OUT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SUM_OUT_B_calc.OUT","PPS:BSYS:1:ST34:SUM_OUT_B.VAL") #! Record("PPS:BSYS:1:ST34:SUM_OUT_B",500,20,0,0,"PPS:BSYS:1:ST34:SUM_OUT_B") #! Field("PPS:BSYS:1:ST34:SUM_OUT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SUM_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi103") { field(DESC, "Port ST34_RDB bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 103, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:ST34:CROSS_TEST_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:CROSS_TEST_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:CROSS_TEST_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:CROSS_TEST_B") { field(DESC, "Cross-interlock testswitch, test mode") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb103",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb103") #! Field("PLC:BSY0:PP08:ST34_RDBb103.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb103.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb103.FLNK","PPS:BSYS:1:ST34:CROSS_TEST_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb103.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb103.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_TEST_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:CROSS_TEST_B_calc") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:CROSS_TEST_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:CROSS_TEST_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb103.VAL") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:CROSS_TEST_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:CROSS_TEST_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:CROSS_TEST_B_calc.OUT","PPS:BSYS:1:ST34:CROSS_TEST_B.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_TEST_B",500,20,0,0,"PPS:BSYS:1:ST34:CROSS_TEST_B") #! Field("PPS:BSYS:1:ST34:CROSS_TEST_B.VAL",16777215,1,"PPS:BSYS:1:ST34:CROSS_TEST_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi102") { field(DESC, "Port ST34_RDB bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 102, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYS:1:ST34:CROSS_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:CROSS_INTLK_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:CROSS_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:CROSS_INTLK_B") { field(DESC, "Cross-intlk testswitch, opposite chain") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb102",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb102") #! Field("PLC:BSY0:PP08:ST34_RDBb102.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb102.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb102.FLNK","PPS:BSYS:1:ST34:CROSS_INTLK_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb102.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb102.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_INTLK_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:CROSS_INTLK_B_calc") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb102.VAL") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:CROSS_INTLK_B_calc.OUT","PPS:BSYS:1:ST34:CROSS_INTLK_B.VAL") #! Record("PPS:BSYS:1:ST34:CROSS_INTLK_B",500,20,0,0,"PPS:BSYS:1:ST34:CROSS_INTLK_B") #! Field("PPS:BSYS:1:ST34:CROSS_INTLK_B.VAL",16777215,1,"PPS:BSYS:1:ST34:CROSS_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi101") { field(DESC, "Port ST34_RDB bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 101, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:BSYS:1:ST34:PERMITTED_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:PERMITTED_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:PERMITTED_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:PERMITTED_B") { field(DESC, "STP-34 Stopper Set Permit") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb101",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb101") #! Field("PLC:BSY0:PP08:ST34_RDBb101.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb101.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb101.FLNK","PPS:BSYS:1:ST34:PERMITTED_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb101.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb101.VAL") #! Record("PPS:BSYS:1:ST34:PERMITTED_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:PERMITTED_B_calc") #! Field("PPS:BSYS:1:ST34:PERMITTED_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:PERMITTED_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:PERMITTED_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb101.VAL") #! Field("PPS:BSYS:1:ST34:PERMITTED_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:PERMITTED_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:PERMITTED_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:PERMITTED_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:PERMITTED_B_calc.OUT","PPS:BSYS:1:ST34:PERMITTED_B.VAL") #! Record("PPS:BSYS:1:ST34:PERMITTED_B",500,20,0,0,"PPS:BSYS:1:ST34:PERMITTED_B") #! Field("PPS:BSYS:1:ST34:PERMITTED_B.VAL",16777215,1,"PPS:BSYS:1:ST34:PERMITTED_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi100") { field(DESC, "Port ST34_RDB bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 100, 1, 1)") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(FLNK, "PPS:BSYS:1:STCLTS:PERMITTED_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:PERMITTED_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:PERMITTED_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:PERMITTED_B") { field(DESC, "STP-CLTS Stopper Permit") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb100",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb100") #! Field("PLC:BSY0:PP08:ST34_RDBb100.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb100.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb100.FLNK","PPS:BSYS:1:STCLTS:PERMITTED_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb100.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb100.VAL") #! Record("PPS:BSYS:1:STCLTS:PERMITTED_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:PERMITTED_B_calc") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:PERMITTED_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:PERMITTED_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb100.VAL") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:PERMITTED_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:PERMITTED_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:PERMITTED_B_calc.OUT","PPS:BSYS:1:STCLTS:PERMITTED_B.VAL") #! Record("PPS:BSYS:1:STCLTS:PERMITTED_B",500,20,0,0,"PPS:BSYS:1:STCLTS:PERMITTED_B") #! Field("PPS:BSYS:1:STCLTS:PERMITTED_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:PERMITTED_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi99") { field(DESC, "Port ST34_RDB bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi99 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B") { field(DESC, "BCS Ok from PLC5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb99",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb99") #! Field("PLC:BSY0:PP08:ST34_RDBb99.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb99.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb99.FLNK","PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb99.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb99.VAL") #! Record("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb99.VAL") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B_calc.OUT","PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B.VAL") #! Record("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B",500,20,0,0,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B") #! Field("PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BCS_FAULT_TRIG_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi98") { field(DESC, "Port ST34_RDB bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 98, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT98_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT98_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi98 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT98_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT98_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb98",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb98") #! Field("PLC:BSY0:PP08:ST34_RDBb98.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb98.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb98.FLNK","PPS:BSYS:1:ST34:BIT98_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb98.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb98.VAL") #! Record("PPS:BSYS:1:ST34:BIT98_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT98_B_calc") #! Field("PPS:BSYS:1:ST34:BIT98_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT98_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT98_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb98.VAL") #! Field("PPS:BSYS:1:ST34:BIT98_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT98_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT98_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT98_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT98_B_calc.OUT","PPS:BSYS:1:ST34:BIT98_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT98_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT98_B") #! Field("PPS:BSYS:1:ST34:BIT98_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT98_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi97") { field(DESC, "Port ST34_RDB bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 97, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:SOLENOID_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:SOLENOID_OUT_B") { field(DESC, "STPR34A solenoid driver output") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb97",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb97") #! Field("PLC:BSY0:PP08:ST34_RDBb97.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb97.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb97.FLNK","PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb97.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb97.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb97.VAL") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34A:SOLENOID_OUT_B_calc.OUT","PPS:BSYS:1:ST34A:SOLENOID_OUT_B.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_OUT_B",500,20,0,0,"PPS:BSYS:1:ST34A:SOLENOID_OUT_B") #! Field("PPS:BSYS:1:ST34A:SOLENOID_OUT_B.VAL",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi96") { field(DESC, "Port ST34_RDB bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 96, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi96 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:SOLENOID_RET_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:SOLENOID_RET_B") { field(DESC, "STPR34A solenoid driver output (RET)") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb96",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb96") #! Field("PLC:BSY0:PP08:ST34_RDBb96.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb96.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb96.FLNK","PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb96.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb96.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc",260,18,0,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.INPA") #! Link("PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb96.VAL") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.INPB") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.OUT") #! Link("PPS:BSYS:1:ST34A:SOLENOID_RET_B_calc.OUT","PPS:BSYS:1:ST34A:SOLENOID_RET_B.VAL") #! Record("PPS:BSYS:1:ST34A:SOLENOID_RET_B",500,20,0,0,"PPS:BSYS:1:ST34A:SOLENOID_RET_B") #! Field("PPS:BSYS:1:ST34A:SOLENOID_RET_B.VAL",16777215,1,"PPS:BSYS:1:ST34A:SOLENOID_RET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi111") { field(DESC, "Port ST34_RDB bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 111, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:SOLENOID_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:SOLENOID_OUT_B") { field(DESC, "STPR34B solenoid driver output") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb111",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb111") #! Field("PLC:BSY0:PP08:ST34_RDBb111.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb111.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb111.FLNK","PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb111.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb111.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb111.VAL") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34B:SOLENOID_OUT_B_calc.OUT","PPS:BSYS:1:ST34B:SOLENOID_OUT_B.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_OUT_B",500,20,0,0,"PPS:BSYS:1:ST34B:SOLENOID_OUT_B") #! Field("PPS:BSYS:1:ST34B:SOLENOID_OUT_B.VAL",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi110") { field(DESC, "Port ST34_RDB bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 110, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:SOLENOID_RET_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:SOLENOID_RET_B") { field(DESC, "STPR34B solenoid driver output (RET)") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb110",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb110") #! Field("PLC:BSY0:PP08:ST34_RDBb110.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb110.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb110.FLNK","PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb110.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb110.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc",260,18,0,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.INPA") #! Link("PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb110.VAL") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.INPB") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.OUT") #! Link("PPS:BSYS:1:ST34B:SOLENOID_RET_B_calc.OUT","PPS:BSYS:1:ST34B:SOLENOID_RET_B.VAL") #! Record("PPS:BSYS:1:ST34B:SOLENOID_RET_B",500,20,0,0,"PPS:BSYS:1:ST34B:SOLENOID_RET_B") #! Field("PPS:BSYS:1:ST34B:SOLENOID_RET_B.VAL",16777215,1,"PPS:BSYS:1:ST34B:SOLENOID_RET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi109") { field(DESC, "Port ST34_RDB bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 109, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:SOLENOID_OUT_B") { field(DESC, "STP-CLTS solenoid driver output") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb109",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb109") #! Field("PLC:BSY0:PP08:ST34_RDBb109.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb109.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb109.FLNK","PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb109.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb109.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb109.VAL") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B_calc.OUT","PPS:BSYS:1:STCLTS:SOLENOID_OUT_B.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B",500,20,0,0,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_B") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_OUT_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi108") { field(DESC, "Port ST34_RDB bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 108, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:SOLENOID_RET_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:SOLENOID_RET_B") { field(DESC, "STP-CLTS solenoid driver output (RET)") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb108",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb108") #! Field("PLC:BSY0:PP08:ST34_RDBb108.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb108.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb108.FLNK","PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb108.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb108.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb108.VAL") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:SOLENOID_RET_B_calc.OUT","PPS:BSYS:1:STCLTS:SOLENOID_RET_B.VAL") #! Record("PPS:BSYS:1:STCLTS:SOLENOID_RET_B",500,20,0,0,"PPS:BSYS:1:STCLTS:SOLENOID_RET_B") #! Field("PPS:BSYS:1:STCLTS:SOLENOID_RET_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:SOLENOID_RET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi107") { field(DESC, "Port ST34_RDB bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 107, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT107_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT107_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT107_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT107_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb107",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb107") #! Field("PLC:BSY0:PP08:ST34_RDBb107.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb107.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb107.FLNK","PPS:BSYS:1:ST34:BIT107_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb107.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb107.VAL") #! Record("PPS:BSYS:1:ST34:BIT107_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT107_B_calc") #! Field("PPS:BSYS:1:ST34:BIT107_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT107_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT107_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb107.VAL") #! Field("PPS:BSYS:1:ST34:BIT107_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT107_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT107_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT107_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT107_B_calc.OUT","PPS:BSYS:1:ST34:BIT107_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT107_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT107_B") #! Field("PPS:BSYS:1:ST34:BIT107_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT107_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi106") { field(DESC, "Port ST34_RDB bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 106, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT106_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT106_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT106_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT106_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb106",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb106") #! Field("PLC:BSY0:PP08:ST34_RDBb106.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb106.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb106.FLNK","PPS:BSYS:1:ST34:BIT106_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb106.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb106.VAL") #! Record("PPS:BSYS:1:ST34:BIT106_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT106_B_calc") #! Field("PPS:BSYS:1:ST34:BIT106_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT106_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT106_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb106.VAL") #! Field("PPS:BSYS:1:ST34:BIT106_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT106_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT106_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT106_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT106_B_calc.OUT","PPS:BSYS:1:ST34:BIT106_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT106_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT106_B") #! Field("PPS:BSYS:1:ST34:BIT106_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT106_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi105") { field(DESC, "Port ST34_RDB bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 105, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B") { field(DESC, "LAT LCLS Secure") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb105",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb105") #! Field("PLC:BSY0:PP08:ST34_RDBb105.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb105.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb105.FLNK","PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb105.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb105.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb105.VAL") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B_calc.OUT","PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B") #! Field("PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:LCLS_SECURE_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi104") { field(DESC, "Port ST34_RDB bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 104, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B") { field(DESC, "LAT BSOICS Group-C OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb104",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb104") #! Field("PLC:BSY0:PP08:ST34_RDBb104.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb104.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb104.FLNK","PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb104.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb104.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb104.VAL") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B_calc.OUT","PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B") #! Field("PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BSOICS_C_OK_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi119") { field(DESC, "Port ST34_RDB bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 119, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:ADMIN_EN_LAT_B") { field(DESC, "LAT STP-34 Admin Enable") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb119",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb119") #! Field("PLC:BSY0:PP08:ST34_RDBb119.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb119.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb119.FLNK","PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb119.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb119.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb119.VAL") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B_calc.OUT","PPS:BSYS:1:ST34:ADMIN_EN_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_B") #! Field("PPS:BSYS:1:ST34:ADMIN_EN_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:ADMIN_EN_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi118") { field(DESC, "Port ST34_RDB bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 118, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi118 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B") { field(DESC, "LAT STP-CLTS Admin Enable") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb118",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb118") #! Field("PLC:BSY0:PP08:ST34_RDBb118.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb118.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb118.FLNK","PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb118.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb118.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb118.VAL") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B_calc.OUT","PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B.VAL") #! Record("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B",500,20,0,0,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B") #! Field("PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:ADMIN_EN_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi117") { field(DESC, "Port ST34_RDB bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 117, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi117 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B") { field(DESC, "LAT PLC5 Panel Stopper Enable Keyswitch") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb117",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb117") #! Field("PLC:BSY0:PP08:ST34_RDBb117.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb117.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb117.FLNK","PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb117.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb117.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb117.VAL") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B_calc.OUT","PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B.VAL") #! Record("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B",500,20,0,0,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B") #! Field("PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B.VAL",16777215,1,"PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi116") { field(DESC, "Port ST34_RDB bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:INTLK_IN_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:INTLK_IN_LAT_B") { field(DESC, "LAT STP-34 Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb116",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb116") #! Field("PLC:BSY0:PP08:ST34_RDBb116.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb116.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb116.FLNK","PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb116.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb116.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb116.VAL") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:INTLK_IN_LAT_B_calc.OUT","PPS:BSYS:1:ST34:INTLK_IN_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34:INTLK_IN_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34:INTLK_IN_LAT_B") #! Field("PPS:BSYS:1:ST34:INTLK_IN_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:INTLK_IN_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi115") { field(DESC, "Port ST34_RDB bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B") { field(DESC, "LAT STP-CLTS Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb115",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb115") #! Field("PLC:BSY0:PP08:ST34_RDBb115.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb115.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb115.FLNK","PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb115.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb115.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb115.VAL") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B_calc.OUT","PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B.VAL") #! Record("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B",500,20,0,0,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B") #! Field("PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:INTLK_IN_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi114") { field(DESC, "Port ST34_RDB bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B") { field(DESC, "LAT BTH not in Test Mode") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb114",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb114") #! Field("PLC:BSY0:PP08:ST34_RDBb114.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb114.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb114.FLNK","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb114.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb114.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb114.VAL") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B_calc.OUT","PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B.VAL") #! Record("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B",500,20,0,0,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B") #! Field("PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B.VAL",16777215,1,"PPS:BSYS:1:BTH:NOT_IN_TEST_MODE_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi113") { field(DESC, "Port ST34_RDB bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_OK_LTH_B") { field(DESC, "LAT Heartbeat OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb113",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb113") #! Field("PLC:BSY0:PP08:ST34_RDBb113.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb113.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb113.FLNK","PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb113.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb113.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb113.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B_calc.OUT","PPS:BSYS:1:ST34:HRTBT_OK_LTH_B.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_B") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_LTH_B.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi112") { field(DESC, "Port ST34_RDB bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 112, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi112 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B") { field(DESC, "LAT SX-Kicker/Sep OFF Summary") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb112",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb112") #! Field("PLC:BSY0:PP08:ST34_RDBb112.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb112.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb112.FLNK","PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb112.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb112.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc",260,18,0,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.INPA",16777215,0,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.INPA") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb112.VAL") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.INPB",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.INPB") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.OUT",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.OUT") #! Link("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B_calc.OUT","PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B.VAL") #! Record("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B",500,20,0,0,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B") #! Field("PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B.VAL",16777215,1,"PPS:LI30:5:SXR:KICKSEP_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi127") { field(DESC, "Port ST34_RDB bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 127, 1, 1)") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B") { field(DESC, "Heartbeat OK") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb127",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb127") #! Field("PLC:BSY0:PP08:ST34_RDBb127.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb127.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb127.FLNK","PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb127.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb127.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb127.VAL") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B_calc.OUT","PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B.VAL") #! Record("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B",500,20,0,0,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B") #! Field("PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B.VAL",16777215,1,"PPS:BSYS:1:ST34:HRTBT_OK_OUTP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi126") { field(DESC, "Port ST34_RDB bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 126, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT126_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT126_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi126 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT126_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT126_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb126",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb126") #! Field("PLC:BSY0:PP08:ST34_RDBb126.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb126.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb126.FLNK","PPS:BSYS:1:ST34:BIT126_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb126.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb126.VAL") #! Record("PPS:BSYS:1:ST34:BIT126_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT126_B_calc") #! Field("PPS:BSYS:1:ST34:BIT126_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT126_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT126_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb126.VAL") #! Field("PPS:BSYS:1:ST34:BIT126_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT126_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT126_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT126_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT126_B_calc.OUT","PPS:BSYS:1:ST34:BIT126_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT126_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT126_B") #! Field("PPS:BSYS:1:ST34:BIT126_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT126_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi125") { field(DESC, "Port ST34_RDB bit 125") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 125, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT125_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT125_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi125 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT125_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT125_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb125",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb125") #! Field("PLC:BSY0:PP08:ST34_RDBb125.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb125.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb125.FLNK","PPS:BSYS:1:ST34:BIT125_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb125.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb125.VAL") #! Record("PPS:BSYS:1:ST34:BIT125_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT125_B_calc") #! Field("PPS:BSYS:1:ST34:BIT125_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT125_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT125_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb125.VAL") #! Field("PPS:BSYS:1:ST34:BIT125_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT125_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT125_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT125_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT125_B_calc.OUT","PPS:BSYS:1:ST34:BIT125_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT125_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT125_B") #! Field("PPS:BSYS:1:ST34:BIT125_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT125_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi124") { field(DESC, "Port ST34_RDB bit 124") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 124, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT124_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT124_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi124 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT124_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT124_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb124",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb124") #! Field("PLC:BSY0:PP08:ST34_RDBb124.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb124.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb124.FLNK","PPS:BSYS:1:ST34:BIT124_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb124.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb124.VAL") #! Record("PPS:BSYS:1:ST34:BIT124_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT124_B_calc") #! Field("PPS:BSYS:1:ST34:BIT124_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT124_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT124_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb124.VAL") #! Field("PPS:BSYS:1:ST34:BIT124_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT124_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT124_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT124_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT124_B_calc.OUT","PPS:BSYS:1:ST34:BIT124_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT124_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT124_B") #! Field("PPS:BSYS:1:ST34:BIT124_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT124_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi123") { field(DESC, "Port ST34_RDB bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 123, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "PPS:BSYS:1:ST34:BIT123_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT123_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT123_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT123_B") { field(DESC, "(spare)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb123",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb123") #! Field("PLC:BSY0:PP08:ST34_RDBb123.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb123.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb123.FLNK","PPS:BSYS:1:ST34:BIT123_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb123.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb123.VAL") #! Record("PPS:BSYS:1:ST34:BIT123_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT123_B_calc") #! Field("PPS:BSYS:1:ST34:BIT123_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT123_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT123_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb123.VAL") #! Field("PPS:BSYS:1:ST34:BIT123_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT123_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT123_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT123_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT123_B_calc.OUT","PPS:BSYS:1:ST34:BIT123_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT123_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT123_B") #! Field("PPS:BSYS:1:ST34:BIT123_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT123_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi122") { field(DESC, "Port ST34_RDB bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 122, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "PPS:BSYS:1:ST34:BIT122_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT122_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi122 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT122_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT122_B") { field(DESC, "(spare)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb122",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb122") #! Field("PLC:BSY0:PP08:ST34_RDBb122.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb122.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb122.FLNK","PPS:BSYS:1:ST34:BIT122_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb122.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb122.VAL") #! Record("PPS:BSYS:1:ST34:BIT122_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT122_B_calc") #! Field("PPS:BSYS:1:ST34:BIT122_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT122_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT122_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb122.VAL") #! Field("PPS:BSYS:1:ST34:BIT122_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT122_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT122_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT122_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT122_B_calc.OUT","PPS:BSYS:1:ST34:BIT122_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT122_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT122_B") #! Field("PPS:BSYS:1:ST34:BIT122_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT122_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi121") { field(DESC, "Port ST34_RDB bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 121, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYS:1:ST34A:STPR_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:STPR_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:STPR_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:STPR_FAULT_B") { field(DESC, "Stopper Fault STP-34A") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb121",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb121") #! Field("PLC:BSY0:PP08:ST34_RDBb121.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb121.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb121.FLNK","PPS:BSYS:1:ST34A:STPR_FAULT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb121.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb121.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34A:STPR_FAULT_B_calc") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb121.VAL") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_B_calc.OUT","PPS:BSYS:1:ST34A:STPR_FAULT_B.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_B",500,20,0,0,"PPS:BSYS:1:ST34A:STPR_FAULT_B") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_B.VAL",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi120") { field(DESC, "Port ST34_RDB bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 120, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYS:1:ST34B:STPR_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:STPR_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:STPR_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:STPR_FAULT_B") { field(DESC, "Stopper Fault STP-34B") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb120",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb120") #! Field("PLC:BSY0:PP08:ST34_RDBb120.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb120.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb120.FLNK","PPS:BSYS:1:ST34B:STPR_FAULT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb120.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb120.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34B:STPR_FAULT_B_calc") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb120.VAL") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_B_calc.OUT","PPS:BSYS:1:ST34B:STPR_FAULT_B.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_B",500,20,0,0,"PPS:BSYS:1:ST34B:STPR_FAULT_B") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_B.VAL",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi135") { field(DESC, "Port ST34_RDB bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 135, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:STPR_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:STPR_FAULT_B") { field(DESC, "Stopper Fault STP-CLTS") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb135",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb135") #! Field("PLC:BSY0:PP08:ST34_RDBb135.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb135.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb135.FLNK","PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb135.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb135.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb135.VAL") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_B_calc.OUT","PPS:BSYS:1:STCLTS:STPR_FAULT_B.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_B",500,20,0,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_B") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi134") { field(DESC, "Port ST34_RDB bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 134, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT134_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT134_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT134_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT134_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb134",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb134") #! Field("PLC:BSY0:PP08:ST34_RDBb134.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb134.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb134.FLNK","PPS:BSYS:1:ST34:BIT134_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb134.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb134.VAL") #! Record("PPS:BSYS:1:ST34:BIT134_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT134_B_calc") #! Field("PPS:BSYS:1:ST34:BIT134_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT134_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT134_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb134.VAL") #! Field("PPS:BSYS:1:ST34:BIT134_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT134_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT134_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT134_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT134_B_calc.OUT","PPS:BSYS:1:ST34:BIT134_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT134_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT134_B") #! Field("PPS:BSYS:1:ST34:BIT134_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT134_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi133") { field(DESC, "Port ST34_RDB bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 133, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:SR_IN_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_IN_OK_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_IN_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_IN_OK_B") { field(DESC, "Safety Relay STP-34 IN OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb133",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb133") #! Field("PLC:BSY0:PP08:ST34_RDBb133.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb133.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb133.FLNK","PPS:BSYS:1:ST34:SR_IN_OK_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb133.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb133.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_IN_OK_B_calc") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_IN_OK_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb133.VAL") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_B_calc.OUT","PPS:BSYS:1:ST34:SR_IN_OK_B.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_B",500,20,0,0,"PPS:BSYS:1:ST34:SR_IN_OK_B") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi132") { field(DESC, "Port ST34_RDB bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 132, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYS:1:ST34:SR_OUT_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_OUT_OK_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_OUT_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_OUT_OK_B") { field(DESC, "Safety Relay STP-34 OUT OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb132",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb132") #! Field("PLC:BSY0:PP08:ST34_RDBb132.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb132.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb132.FLNK","PPS:BSYS:1:ST34:SR_OUT_OK_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb132.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb132.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_OUT_OK_B_calc") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb132.VAL") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_B_calc.OUT","PPS:BSYS:1:ST34:SR_OUT_OK_B.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_B",500,20,0,0,"PPS:BSYS:1:ST34:SR_OUT_OK_B") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi131") { field(DESC, "Port ST34_RDB bit 131") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 131, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT131_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT131_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi131 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT131_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT131_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb131",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb131") #! Field("PLC:BSY0:PP08:ST34_RDBb131.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb131.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb131.FLNK","PPS:BSYS:1:ST34:BIT131_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb131.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb131.VAL") #! Record("PPS:BSYS:1:ST34:BIT131_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT131_B_calc") #! Field("PPS:BSYS:1:ST34:BIT131_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT131_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT131_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb131.VAL") #! Field("PPS:BSYS:1:ST34:BIT131_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT131_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT131_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT131_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT131_B_calc.OUT","PPS:BSYS:1:ST34:BIT131_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT131_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT131_B") #! Field("PPS:BSYS:1:ST34:BIT131_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT131_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi130") { field(DESC, "Port ST34_RDB bit 130") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 130, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT130_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT130_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi130 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT130_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT130_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb130",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb130") #! Field("PLC:BSY0:PP08:ST34_RDBb130.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb130.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb130.FLNK","PPS:BSYS:1:ST34:BIT130_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb130.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb130.VAL") #! Record("PPS:BSYS:1:ST34:BIT130_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT130_B_calc") #! Field("PPS:BSYS:1:ST34:BIT130_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT130_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT130_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb130.VAL") #! Field("PPS:BSYS:1:ST34:BIT130_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT130_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT130_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT130_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT130_B_calc.OUT","PPS:BSYS:1:ST34:BIT130_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT130_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT130_B") #! Field("PPS:BSYS:1:ST34:BIT130_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT130_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi129") { field(DESC, "Port ST34_RDB bit 129") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 129, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT129_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT129_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi129 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT129_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT129_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb129",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb129") #! Field("PLC:BSY0:PP08:ST34_RDBb129.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb129.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb129.FLNK","PPS:BSYS:1:ST34:BIT129_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb129.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb129.VAL") #! Record("PPS:BSYS:1:ST34:BIT129_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT129_B_calc") #! Field("PPS:BSYS:1:ST34:BIT129_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT129_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT129_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb129.VAL") #! Field("PPS:BSYS:1:ST34:BIT129_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT129_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT129_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT129_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT129_B_calc.OUT","PPS:BSYS:1:ST34:BIT129_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT129_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT129_B") #! Field("PPS:BSYS:1:ST34:BIT129_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT129_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi128") { field(DESC, "Port ST34_RDB bit 128") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 128, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT128_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT128_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi128 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT128_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT128_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb128",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb128") #! Field("PLC:BSY0:PP08:ST34_RDBb128.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb128.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb128.FLNK","PPS:BSYS:1:ST34:BIT128_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb128.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb128.VAL") #! Record("PPS:BSYS:1:ST34:BIT128_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT128_B_calc") #! Field("PPS:BSYS:1:ST34:BIT128_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT128_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT128_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb128.VAL") #! Field("PPS:BSYS:1:ST34:BIT128_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT128_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT128_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT128_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT128_B_calc.OUT","PPS:BSYS:1:ST34:BIT128_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT128_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT128_B") #! Field("PPS:BSYS:1:ST34:BIT128_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT128_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi143") { field(DESC, "Port ST34_RDB bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 143, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B") { field(DESC, "LAT Stopper Fault STP-34A") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb143",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb143") #! Field("PLC:BSY0:PP08:ST34_RDBb143.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb143.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb143.FLNK","PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb143.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb143.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb143.VAL") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B_calc.OUT","PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B") #! Field("PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34A:STPR_FAULT_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi142") { field(DESC, "Port ST34_RDB bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 142, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B") { field(DESC, "LAT Stopper Fault STP-34B") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb142",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb142") #! Field("PLC:BSY0:PP08:ST34_RDBb142.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb142.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb142.FLNK","PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb142.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb142.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb142.VAL") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B_calc.OUT","PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B") #! Field("PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34B:STPR_FAULT_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi141") { field(DESC, "Port ST34_RDB bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 141, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B") { field(DESC, "LAT Stopper Fault STP-CLTS") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb141",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb141") #! Field("PLC:BSY0:PP08:ST34_RDBb141.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb141.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb141.FLNK","PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb141.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb141.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb141.VAL") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B_calc.OUT","PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B.VAL") #! Record("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B",500,20,0,0,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B") #! Field("PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B.VAL",16777215,1,"PPS:BSYS:1:STCLTS:STPR_FAULT_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi140") { field(DESC, "Port ST34_RDB bit 140") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 140, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(FLNK, "PPS:BSYS:1:ST34:BIT140_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:BIT140_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi140 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:BIT140_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:BIT140_B") { field(DESC, "(spare)") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb140",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb140") #! Field("PLC:BSY0:PP08:ST34_RDBb140.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb140.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb140.FLNK","PPS:BSYS:1:ST34:BIT140_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb140.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb140.VAL") #! Record("PPS:BSYS:1:ST34:BIT140_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:BIT140_B_calc") #! Field("PPS:BSYS:1:ST34:BIT140_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:BIT140_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:BIT140_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb140.VAL") #! Field("PPS:BSYS:1:ST34:BIT140_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:BIT140_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:BIT140_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:BIT140_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:BIT140_B_calc.OUT","PPS:BSYS:1:ST34:BIT140_B.VAL") #! Record("PPS:BSYS:1:ST34:BIT140_B",500,20,0,0,"PPS:BSYS:1:ST34:BIT140_B") #! Field("PPS:BSYS:1:ST34:BIT140_B.VAL",16777215,1,"PPS:BSYS:1:ST34:BIT140_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi139") { field(DESC, "Port ST34_RDB bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 139, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_IN_OK_LAT_B") { field(DESC, "LAT Safety Relay STP-34 IN OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb139",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb139") #! Field("PLC:BSY0:PP08:ST34_RDBb139.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb139.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb139.FLNK","PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb139.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb139.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb139.VAL") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B_calc.OUT","PPS:BSYS:1:ST34:SR_IN_OK_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_B") #! Field("PPS:BSYS:1:ST34:SR_IN_OK_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_IN_OK_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP08:Bi138") { field(DESC, "Port ST34_RDB bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc") { field(INPA, "PLC:BSY0:PP08:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP08:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B") { field(DESC, "LAT Safety Relay STP-34 OUT OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP08:ST34_RDBb138",20,19,0,0,"PLC:BSY0:PP08:ST34_RDBb138") #! Field("PLC:BSY0:PP08:ST34_RDBb138.FLNK",16777215,1,"PLC:BSY0:PP08:ST34_RDBb138.FLNK") #! Link("PLC:BSY0:PP08:ST34_RDBb138.FLNK","PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc") #! Field("PLC:BSY0:PP08:ST34_RDBb138.VAL",16777215,0,"PLC:BSY0:PP08:ST34_RDBb138.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc",260,18,0,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.INPA",16777215,0,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.INPA") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.INPA","PLC:BSY0:PP08:ST34_RDBb138.VAL") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.INPB",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.INPB") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.OUT",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.OUT") #! Link("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B_calc.OUT","PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B.VAL") #! Record("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B",500,20,0,0,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B") #! Field("PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B.VAL",16777215,1,"PPS:BSYS:1:ST34:SR_OUT_OK_LAT_B.VAL") record(bo, "PPS:BSYS:1:ST34:RESET_INTLK_B") { field(DESC, "ST34_Interlock_Reset_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:PAUSEHB_B") { field(DESC, "ST34_Pause_Heartbeat_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:SET_IN_B") { field(DESC, "Send_ST34_Set_In_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 5, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:SET_OUT_B") { field(DESC, "Send_ST34_Set_Out_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 4, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:STCLTS:SET_IN_B") { field(DESC, "Send_STCLTS_Set_In_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 3, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:STCLTS:SET_OUT_B") { field(DESC, "Send_STCLTS_Set_Out_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 2, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP08:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP08:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP08:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP08:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP08:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP08:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP08:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP08:REQ_SEG CP") field( INPC, "PLC:BSY0:PP08:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP08:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP08:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP08:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP08:REQ_SEG CP") field( INPC, "PLC:BSY0:PP08:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP08:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP08:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP08:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP08:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP08:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP08:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP08:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP08:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP08:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP08:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP08:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP08:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP08:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP08:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP08:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP08:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP08:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP08:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP08:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP08:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP08:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP08:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP08:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP08:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP08:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP08:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP08:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP08:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP08:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP08:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP08:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP08:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP08:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP08:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP08:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP08:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP08:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP08:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP08:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP08:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP08:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP08:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP08:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP08:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP08:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP08:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP08:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP08:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP08:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP08:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP08:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP08:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP08:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_RDB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP08:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(ST34_WRTB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP08:w0") { field(DESC, "ST34 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:w1") { field(DESC, "ST34 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP08:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP08:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP08:w3") { field(DESC, "ST34 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP08:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP08:w3 PP MS") field(INPB, "PLC:BSY0:PP08:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP08:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP08:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP08:w4") { field(DESC, "ST34 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP08:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP08:w4 NPP MS") field(INPB, "PLC:BSY0:PP08:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP08:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP08:w5") { field(DESC, "ST34 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP08:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP08:w5 NPP MS") field(INPB, "PLC:BSY0:PP08:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP08:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP08:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP08:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP08:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP08:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP08:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP08:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP08:w6 NPP MS") field(INPB, "PLC:BSY0:PP08:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP08:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP08:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP08:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP08:w7 NPP MS") field(INPB, "PLC:BSY0:PP08:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP08:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(ST34_WDB, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP08:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP08:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP08:w8 NPP MS") field(INPB, "PLC:BSY0:PP08:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP08:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP08:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP08:OP_HOURS") { field(INPA, "PLC:BSY0:PP08:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP08:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP08:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP08:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP08:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(ST34_RDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP08:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP08:RDHist.PROC") } record(waveform,"PLC:BSY0:PP08:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_RDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP08:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP08:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_RDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP08:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP08:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(ST34_RDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP08:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP08:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP08:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP08:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP08:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP08:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP08:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP08:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP08:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_RDB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP08:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(ST34_WRTB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP08:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP08:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP08:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WRTB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP08:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP08:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WRTB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP08:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP08:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(ST34_WRTB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP08:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTB 0)READ_OK") field(FLNK,"PLC:BSY0:PP08:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP08:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP08:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP08:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP08:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP08:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP08:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP08:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WRTB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP08:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(ST34_WDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP08:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP08:WDHist.PROC") } record(waveform,"PLC:BSY0:PP08:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP08:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP08:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(ST34_WDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP08:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP08:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(ST34_WDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP08:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP08:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP08:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP08:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP08:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP08:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP08:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP08:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP08:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(ST34_WDB 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi7") { field(DESC, "Port D2_RDA bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYH:1:STD2:HW_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HW_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HW_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HW_ENABLE_A") { field(DESC, "D2_HW_Enable_A") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb7",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb7") #! Field("PLC:BSY0:PP05:D2_RDAb7.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb7.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb7.FLNK","PPS:BSYH:1:STD2:HW_ENABLE_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb7.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb7.VAL") #! Record("PPS:BSYH:1:STD2:HW_ENABLE_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:HW_ENABLE_A_calc") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HW_ENABLE_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:HW_ENABLE_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb7.VAL") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HW_ENABLE_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HW_ENABLE_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:HW_ENABLE_A_calc.OUT","PPS:BSYH:1:STD2:HW_ENABLE_A.VAL") #! Record("PPS:BSYH:1:STD2:HW_ENABLE_A",500,20,0,0,"PPS:BSYH:1:STD2:HW_ENABLE_A") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_A.VAL",16777215,1,"PPS:BSYH:1:STD2:HW_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi6") { field(DESC, "Port D2_RDA bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 6, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:XINTLK_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:XINTLK_IN_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:XINTLK_IN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:XINTLK_IN_A") { field(DESC, "Cross_Intlk_Input_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb6",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb6") #! Field("PLC:BSY0:PP05:D2_RDAb6.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb6.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb6.FLNK","PPS:BSYH:1:STD2:XINTLK_IN_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb6.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb6.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_IN_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:XINTLK_IN_A_calc") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:XINTLK_IN_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:XINTLK_IN_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb6.VAL") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:XINTLK_IN_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:XINTLK_IN_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:XINTLK_IN_A_calc.OUT","PPS:BSYH:1:STD2:XINTLK_IN_A.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_IN_A",500,20,0,0,"PPS:BSYH:1:STD2:XINTLK_IN_A") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_A.VAL",16777215,1,"PPS:BSYH:1:STD2:XINTLK_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi5") { field(DESC, "Port D2_RDA bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 5, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:BSYH:1:STD2:LCLS_SECURE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:LCLS_SECURE_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:LCLS_SECURE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:LCLS_SECURE_A") { field(DESC, "LCLS Secure A") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb5",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb5") #! Field("PLC:BSY0:PP05:D2_RDAb5.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb5.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb5.FLNK","PPS:BSYH:1:STD2:LCLS_SECURE_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb5.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb5.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:LCLS_SECURE_A_calc") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb5.VAL") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_A_calc.OUT","PPS:BSYH:1:STD2:LCLS_SECURE_A.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_A",500,20,0,0,"PPS:BSYH:1:STD2:LCLS_SECURE_A") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_A.VAL",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi4") { field(DESC, "Port D2_RDA bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 4, 1, 1)") field(ZNAM, "Not_OK") field(ONAM, "OK") field(FLNK, "PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi4 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:BSOICS_C_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:BSOICS_C_OK_A") { field(DESC, "BSOICs Grp. C OK A") field(ZNAM, "Not_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb4",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb4") #! Field("PLC:BSY0:PP05:D2_RDAb4.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb4.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb4.FLNK","PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb4.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb4.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb4.VAL") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_A_calc.OUT","PPS:BSYH:1:STD2:BSOICS_C_OK_A.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_A",500,20,0,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_A") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_A.VAL",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi2") { field(DESC, "Port D2_RDA bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 2, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI28:1:HXR:KICK_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICK_OFF_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICK_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICK_OFF_A") { field(DESC, "HXR_Kicker_Off_Sum_A") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb2",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb2") #! Field("PLC:BSY0:PP05:D2_RDAb2.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb2.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb2.FLNK","PPS:LI28:1:HXR:KICK_OFF_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb2.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb2.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_A_calc",260,18,0,1,"PPS:LI28:1:HXR:KICK_OFF_A_calc") #! Field("PPS:LI28:1:HXR:KICK_OFF_A_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICK_OFF_A_calc.INPA") #! Link("PPS:LI28:1:HXR:KICK_OFF_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb2.VAL") #! Field("PPS:LI28:1:HXR:KICK_OFF_A_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_A_calc.INPB") #! Field("PPS:LI28:1:HXR:KICK_OFF_A_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_A_calc.OUT") #! Link("PPS:LI28:1:HXR:KICK_OFF_A_calc.OUT","PPS:LI28:1:HXR:KICK_OFF_A.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_A",500,20,0,0,"PPS:LI28:1:HXR:KICK_OFF_A") #! Field("PPS:LI28:1:HXR:KICK_OFF_A.VAL",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi1") { field(DESC, "Port D2_RDA bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 1, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:BSYH:1:STD2:GEN_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:GEN_INTLK_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:GEN_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:GEN_INTLK_A") { field(DESC, "Generic_D2_Interlock_A") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb1",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb1") #! Field("PLC:BSY0:PP05:D2_RDAb1.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb1.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb1.FLNK","PPS:BSYH:1:STD2:GEN_INTLK_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb1.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb1.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:GEN_INTLK_A_calc") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:GEN_INTLK_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb1.VAL") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_A_calc.OUT","PPS:BSYH:1:STD2:GEN_INTLK_A.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_A",500,20,0,0,"PPS:BSYH:1:STD2:GEN_INTLK_A") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_A.VAL",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi0") { field(DESC, "Port D2_RDA bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 0, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYH:1:STD2:TEST_MODE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:TEST_MODE_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:TEST_MODE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:TEST_MODE_A") { field(DESC, "D2_Test_Keysw_Status_A") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb0",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb0") #! Field("PLC:BSY0:PP05:D2_RDAb0.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb0.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb0.FLNK","PPS:BSYH:1:STD2:TEST_MODE_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb0.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb0.VAL") #! Record("PPS:BSYH:1:STD2:TEST_MODE_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:TEST_MODE_A_calc") #! Field("PPS:BSYH:1:STD2:TEST_MODE_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:TEST_MODE_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:TEST_MODE_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb0.VAL") #! Field("PPS:BSYH:1:STD2:TEST_MODE_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:TEST_MODE_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:TEST_MODE_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:TEST_MODE_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:TEST_MODE_A_calc.OUT","PPS:BSYH:1:STD2:TEST_MODE_A.VAL") #! Record("PPS:BSYH:1:STD2:TEST_MODE_A",500,20,0,0,"PPS:BSYH:1:STD2:TEST_MODE_A") #! Field("PPS:BSYH:1:STD2:TEST_MODE_A.VAL",16777215,1,"PPS:BSYH:1:STD2:TEST_MODE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi15") { field(DESC, "Port D2_RDA bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_INP_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_INP_A") { field(DESC, "Heartbeat In (from other chn.)") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb15",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb15") #! Field("PLC:BSY0:PP05:D2_RDAb15.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb15.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb15.FLNK","PPS:BSYH:1:STD2:HRTBT_INP_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb15.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb15.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_INP_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_INP_A_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_INP_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_INP_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb15.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_INP_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_INP_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_INP_A_calc.OUT","PPS:BSYH:1:STD2:HRTBT_INP_A.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_INP_A",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_INP_A") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_A.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi14") { field(DESC, "Port D2_RDA bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 14, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOPPER_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOPPER_ENABLE_A") { field(DESC, "Local_STD2_Enable_Keysw_A") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb14",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb14") #! Field("PLC:BSY0:PP05:D2_RDAb14.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb14.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb14.FLNK","PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb14.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb14.VAL") #! Record("PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb14.VAL") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOPPER_ENABLE_A_calc.OUT","PPS:BSYH:1:STD2:STOPPER_ENABLE_A.VAL") #! Record("PPS:BSYH:1:STD2:STOPPER_ENABLE_A",500,20,0,0,"PPS:BSYH:1:STD2:STOPPER_ENABLE_A") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_A.VAL",16777215,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi13") { field(DESC, "Port D2_RDA bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 13, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:847:INA_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:INA_calc") { field(INPA, "PLC:BSY0:PP05:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:INA PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:INA") { field(DESC, "STD2_IN_Limit_Switch_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb13",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb13") #! Field("PLC:BSY0:PP05:D2_RDAb13.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb13.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb13.FLNK","STPR:BSYH:847:INA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb13.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb13.VAL") #! Record("STPR:BSYH:847:INA_calc",260,18,0,1,"STPR:BSYH:847:INA_calc") #! Field("STPR:BSYH:847:INA_calc.INPA",16777215,0,"STPR:BSYH:847:INA_calc.INPA") #! Link("STPR:BSYH:847:INA_calc.INPA","PLC:BSY0:PP05:D2_RDAb13.VAL") #! Field("STPR:BSYH:847:INA_calc.INPB",16777215,1,"STPR:BSYH:847:INA_calc.INPB") #! Field("STPR:BSYH:847:INA_calc.OUT",16777215,1,"STPR:BSYH:847:INA_calc.OUT") #! Link("STPR:BSYH:847:INA_calc.OUT","STPR:BSYH:847:INA.VAL") #! Record("STPR:BSYH:847:INA",500,20,0,0,"STPR:BSYH:847:INA") #! Field("STPR:BSYH:847:INA.VAL",16777215,1,"STPR:BSYH:847:INA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi12") { field(DESC, "Port D2_RDA bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 12, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:847:OUTA_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:OUTA_calc") { field(INPA, "PLC:BSY0:PP05:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:OUTA PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:OUTA") { field(DESC, "STD2_OUT_Limit_Switch_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb12",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb12") #! Field("PLC:BSY0:PP05:D2_RDAb12.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb12.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb12.FLNK","STPR:BSYH:847:OUTA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb12.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb12.VAL") #! Record("STPR:BSYH:847:OUTA_calc",260,18,0,1,"STPR:BSYH:847:OUTA_calc") #! Field("STPR:BSYH:847:OUTA_calc.INPA",16777215,0,"STPR:BSYH:847:OUTA_calc.INPA") #! Link("STPR:BSYH:847:OUTA_calc.INPA","PLC:BSY0:PP05:D2_RDAb12.VAL") #! Field("STPR:BSYH:847:OUTA_calc.INPB",16777215,1,"STPR:BSYH:847:OUTA_calc.INPB") #! Field("STPR:BSYH:847:OUTA_calc.OUT",16777215,1,"STPR:BSYH:847:OUTA_calc.OUT") #! Link("STPR:BSYH:847:OUTA_calc.OUT","STPR:BSYH:847:OUTA.VAL") #! Record("STPR:BSYH:847:OUTA",500,20,0,0,"STPR:BSYH:847:OUTA") #! Field("STPR:BSYH:847:OUTA.VAL",16777215,1,"STPR:BSYH:847:OUTA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi11") { field(DESC, "Port D2_RDA bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 11, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:854:INA_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:INA_calc") { field(INPA, "PLC:BSY0:PP05:Bi11 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:INA PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:INA") { field(DESC, "ST60_IN_Limit_Switch_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb11",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb11") #! Field("PLC:BSY0:PP05:D2_RDAb11.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb11.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb11.FLNK","STPR:BSYH:854:INA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb11.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb11.VAL") #! Record("STPR:BSYH:854:INA_calc",260,18,0,1,"STPR:BSYH:854:INA_calc") #! Field("STPR:BSYH:854:INA_calc.INPA",16777215,0,"STPR:BSYH:854:INA_calc.INPA") #! Link("STPR:BSYH:854:INA_calc.INPA","PLC:BSY0:PP05:D2_RDAb11.VAL") #! Field("STPR:BSYH:854:INA_calc.INPB",16777215,1,"STPR:BSYH:854:INA_calc.INPB") #! Field("STPR:BSYH:854:INA_calc.OUT",16777215,1,"STPR:BSYH:854:INA_calc.OUT") #! Link("STPR:BSYH:854:INA_calc.OUT","STPR:BSYH:854:INA.VAL") #! Record("STPR:BSYH:854:INA",500,20,0,0,"STPR:BSYH:854:INA") #! Field("STPR:BSYH:854:INA.VAL",16777215,1,"STPR:BSYH:854:INA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi10") { field(DESC, "Port D2_RDA bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 10, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:854:OUTA_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:OUTA_calc") { field(INPA, "PLC:BSY0:PP05:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:OUTA PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:OUTA") { field(DESC, "ST60_OUT_Limit_Switch_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb10",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb10") #! Field("PLC:BSY0:PP05:D2_RDAb10.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb10.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb10.FLNK","STPR:BSYH:854:OUTA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb10.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb10.VAL") #! Record("STPR:BSYH:854:OUTA_calc",260,18,0,1,"STPR:BSYH:854:OUTA_calc") #! Field("STPR:BSYH:854:OUTA_calc.INPA",16777215,0,"STPR:BSYH:854:OUTA_calc.INPA") #! Link("STPR:BSYH:854:OUTA_calc.INPA","PLC:BSY0:PP05:D2_RDAb10.VAL") #! Field("STPR:BSYH:854:OUTA_calc.INPB",16777215,1,"STPR:BSYH:854:OUTA_calc.INPB") #! Field("STPR:BSYH:854:OUTA_calc.OUT",16777215,1,"STPR:BSYH:854:OUTA_calc.OUT") #! Link("STPR:BSYH:854:OUTA_calc.OUT","STPR:BSYH:854:OUTA.VAL") #! Record("STPR:BSYH:854:OUTA",500,20,0,0,"STPR:BSYH:854:OUTA") #! Field("STPR:BSYH:854:OUTA.VAL",16777215,1,"STPR:BSYH:854:OUTA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi9") { field(DESC, "Port D2_RDA bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 9, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:905:INA_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:INA_calc") { field(INPA, "PLC:BSY0:PP05:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:INA PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:INA") { field(DESC, "ST61_IN_Limit_Switch_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb9",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb9") #! Field("PLC:BSY0:PP05:D2_RDAb9.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb9.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb9.FLNK","STPR:BSYH:905:INA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb9.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb9.VAL") #! Record("STPR:BSYH:905:INA_calc",260,18,0,1,"STPR:BSYH:905:INA_calc") #! Field("STPR:BSYH:905:INA_calc.INPA",16777215,0,"STPR:BSYH:905:INA_calc.INPA") #! Link("STPR:BSYH:905:INA_calc.INPA","PLC:BSY0:PP05:D2_RDAb9.VAL") #! Field("STPR:BSYH:905:INA_calc.INPB",16777215,1,"STPR:BSYH:905:INA_calc.INPB") #! Field("STPR:BSYH:905:INA_calc.OUT",16777215,1,"STPR:BSYH:905:INA_calc.OUT") #! Link("STPR:BSYH:905:INA_calc.OUT","STPR:BSYH:905:INA.VAL") #! Record("STPR:BSYH:905:INA",500,20,0,0,"STPR:BSYH:905:INA") #! Field("STPR:BSYH:905:INA.VAL",16777215,1,"STPR:BSYH:905:INA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi8") { field(DESC, "Port D2_RDA bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 8, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:905:OUTA_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:OUTA_calc") { field(INPA, "PLC:BSY0:PP05:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:OUTA PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:OUTA") { field(DESC, "ST61_OUT_Limit_Switch_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb8",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb8") #! Field("PLC:BSY0:PP05:D2_RDAb8.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb8.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb8.FLNK","STPR:BSYH:905:OUTA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb8.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb8.VAL") #! Record("STPR:BSYH:905:OUTA_calc",260,18,0,1,"STPR:BSYH:905:OUTA_calc") #! Field("STPR:BSYH:905:OUTA_calc.INPA",16777215,0,"STPR:BSYH:905:OUTA_calc.INPA") #! Link("STPR:BSYH:905:OUTA_calc.INPA","PLC:BSY0:PP05:D2_RDAb8.VAL") #! Field("STPR:BSYH:905:OUTA_calc.INPB",16777215,1,"STPR:BSYH:905:OUTA_calc.INPB") #! Field("STPR:BSYH:905:OUTA_calc.OUT",16777215,1,"STPR:BSYH:905:OUTA_calc.OUT") #! Link("STPR:BSYH:905:OUTA_calc.OUT","STPR:BSYH:905:OUTA.VAL") #! Record("STPR:BSYH:905:OUTA",500,20,0,0,"STPR:BSYH:905:OUTA") #! Field("STPR:BSYH:905:OUTA.VAL",16777215,1,"STPR:BSYH:905:OUTA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi23") { field(DESC, "Port D2_RDA bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 23, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "BTM:BSYH:858:INA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:INA_calc") { field(INPA, "PLC:BSY0:PP05:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:INA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:INA") { field(DESC, "DM60_IN_Limit_Switch_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb23",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb23") #! Field("PLC:BSY0:PP05:D2_RDAb23.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb23.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb23.FLNK","BTM:BSYH:858:INA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb23.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb23.VAL") #! Record("BTM:BSYH:858:INA_calc",260,18,0,1,"BTM:BSYH:858:INA_calc") #! Field("BTM:BSYH:858:INA_calc.INPA",16777215,0,"BTM:BSYH:858:INA_calc.INPA") #! Link("BTM:BSYH:858:INA_calc.INPA","PLC:BSY0:PP05:D2_RDAb23.VAL") #! Field("BTM:BSYH:858:INA_calc.INPB",16777215,1,"BTM:BSYH:858:INA_calc.INPB") #! Field("BTM:BSYH:858:INA_calc.OUT",16777215,1,"BTM:BSYH:858:INA_calc.OUT") #! Link("BTM:BSYH:858:INA_calc.OUT","BTM:BSYH:858:INA.VAL") #! Record("BTM:BSYH:858:INA",500,20,0,0,"BTM:BSYH:858:INA") #! Field("BTM:BSYH:858:INA.VAL",16777215,1,"BTM:BSYH:858:INA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi22") { field(DESC, "Port D2_RDA bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 22, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "BTM:BSYH:858:OUTA_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:OUTA_calc") { field(INPA, "PLC:BSY0:PP05:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:OUTA PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:OUTA") { field(DESC, "DM60_OUT_Limit_Switch_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb22",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb22") #! Field("PLC:BSY0:PP05:D2_RDAb22.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb22.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb22.FLNK","BTM:BSYH:858:OUTA_calc") #! Field("PLC:BSY0:PP05:D2_RDAb22.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb22.VAL") #! Record("BTM:BSYH:858:OUTA_calc",260,18,0,1,"BTM:BSYH:858:OUTA_calc") #! Field("BTM:BSYH:858:OUTA_calc.INPA",16777215,0,"BTM:BSYH:858:OUTA_calc.INPA") #! Link("BTM:BSYH:858:OUTA_calc.INPA","PLC:BSY0:PP05:D2_RDAb22.VAL") #! Field("BTM:BSYH:858:OUTA_calc.INPB",16777215,1,"BTM:BSYH:858:OUTA_calc.INPB") #! Field("BTM:BSYH:858:OUTA_calc.OUT",16777215,1,"BTM:BSYH:858:OUTA_calc.OUT") #! Link("BTM:BSYH:858:OUTA_calc.OUT","BTM:BSYH:858:OUTA.VAL") #! Record("BTM:BSYH:858:OUTA",500,20,0,0,"BTM:BSYH:858:OUTA") #! Field("BTM:BSYH:858:OUTA.VAL",16777215,1,"BTM:BSYH:858:OUTA.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi21") { field(DESC, "Port D2_RDA bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 21, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:1:STD2_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:STD2_IN_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:STD2_IN_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:STD2_IN_A") { field(DESC, "STD2_SR_FDBK_In_Sum_Inp_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb21",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb21") #! Field("PLC:BSY0:PP05:D2_RDAb21.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb21.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb21.FLNK","STPR:BSYH:1:STD2_IN_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb21.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb21.VAL") #! Record("STPR:BSYH:1:STD2_IN_A_calc",260,18,0,1,"STPR:BSYH:1:STD2_IN_A_calc") #! Field("STPR:BSYH:1:STD2_IN_A_calc.INPA",16777215,0,"STPR:BSYH:1:STD2_IN_A_calc.INPA") #! Link("STPR:BSYH:1:STD2_IN_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb21.VAL") #! Field("STPR:BSYH:1:STD2_IN_A_calc.INPB",16777215,1,"STPR:BSYH:1:STD2_IN_A_calc.INPB") #! Field("STPR:BSYH:1:STD2_IN_A_calc.OUT",16777215,1,"STPR:BSYH:1:STD2_IN_A_calc.OUT") #! Link("STPR:BSYH:1:STD2_IN_A_calc.OUT","STPR:BSYH:1:STD2_IN_A.VAL") #! Record("STPR:BSYH:1:STD2_IN_A",500,20,0,0,"STPR:BSYH:1:STD2_IN_A") #! Field("STPR:BSYH:1:STD2_IN_A.VAL",16777215,1,"STPR:BSYH:1:STD2_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi20") { field(DESC, "Port D2_RDA bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 20, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:1:STD2_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:STD2_OUT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:STD2_OUT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:STD2_OUT_A") { field(DESC, "STD2_SR_FDBK_Out_Sum_Inp_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb20",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb20") #! Field("PLC:BSY0:PP05:D2_RDAb20.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb20.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb20.FLNK","STPR:BSYH:1:STD2_OUT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb20.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb20.VAL") #! Record("STPR:BSYH:1:STD2_OUT_A_calc",260,18,0,1,"STPR:BSYH:1:STD2_OUT_A_calc") #! Field("STPR:BSYH:1:STD2_OUT_A_calc.INPA",16777215,0,"STPR:BSYH:1:STD2_OUT_A_calc.INPA") #! Link("STPR:BSYH:1:STD2_OUT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb20.VAL") #! Field("STPR:BSYH:1:STD2_OUT_A_calc.INPB",16777215,1,"STPR:BSYH:1:STD2_OUT_A_calc.INPB") #! Field("STPR:BSYH:1:STD2_OUT_A_calc.OUT",16777215,1,"STPR:BSYH:1:STD2_OUT_A_calc.OUT") #! Link("STPR:BSYH:1:STD2_OUT_A_calc.OUT","STPR:BSYH:1:STD2_OUT_A.VAL") #! Record("STPR:BSYH:1:STD2_OUT_A",500,20,0,0,"STPR:BSYH:1:STD2_OUT_A") #! Field("STPR:BSYH:1:STD2_OUT_A.VAL",16777215,1,"STPR:BSYH:1:STD2_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi19") { field(DESC, "Port D2_RDA bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 19, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYH:1:STD2_ADMIN_EN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2_ADMIN_EN_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi19 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2_ADMIN_EN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2_ADMIN_EN_A") { field(DESC, "STD2_Admin_Enable_Keysw_A") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb19",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb19") #! Field("PLC:BSY0:PP05:D2_RDAb19.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb19.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb19.FLNK","PPS:BSYH:1:STD2_ADMIN_EN_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb19.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb19.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_A_calc",260,18,0,1,"PPS:BSYH:1:STD2_ADMIN_EN_A_calc") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2_ADMIN_EN_A_calc.INPA") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb19.VAL") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_A_calc.INPB") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_A_calc.OUT") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_A_calc.OUT","PPS:BSYH:1:STD2_ADMIN_EN_A.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_A",500,20,0,0,"PPS:BSYH:1:STD2_ADMIN_EN_A") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_A.VAL",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi18") { field(DESC, "Port D2_RDA bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 18, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYH:847:MOTOR_PWR_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_PWR_OK_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi18 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_PWR_OK_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_PWR_OK_A") { field(DESC, "STD2_Motor_Power_OK_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb18",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb18") #! Field("PLC:BSY0:PP05:D2_RDAb18.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb18.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb18.FLNK","STPR:BSYH:847:MOTOR_PWR_OK_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb18.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb18.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_A_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_PWR_OK_A_calc") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_A_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_PWR_OK_A_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb18.VAL") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_A_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_A_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_A_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_A_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_A_calc.OUT","STPR:BSYH:847:MOTOR_PWR_OK_A.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_A",500,20,0,0,"STPR:BSYH:847:MOTOR_PWR_OK_A") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_A.VAL",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi17") { field(DESC, "Port D2_RDA bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 17, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYH:1:BTH_TEST_MODE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:BTH_TEST_MODE_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi17 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:BTH_TEST_MODE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:BTH_TEST_MODE_A") { field(DESC, "BTH_In_Test_Mode_A") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb17",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb17") #! Field("PLC:BSY0:PP05:D2_RDAb17.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb17.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb17.FLNK","PPS:BSYH:1:BTH_TEST_MODE_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb17.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb17.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_A_calc",260,18,0,1,"PPS:BSYH:1:BTH_TEST_MODE_A_calc") #! Field("PPS:BSYH:1:BTH_TEST_MODE_A_calc.INPA",16777215,0,"PPS:BSYH:1:BTH_TEST_MODE_A_calc.INPA") #! Link("PPS:BSYH:1:BTH_TEST_MODE_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb17.VAL") #! Field("PPS:BSYH:1:BTH_TEST_MODE_A_calc.INPB",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_A_calc.INPB") #! Field("PPS:BSYH:1:BTH_TEST_MODE_A_calc.OUT",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_A_calc.OUT") #! Link("PPS:BSYH:1:BTH_TEST_MODE_A_calc.OUT","PPS:BSYH:1:BTH_TEST_MODE_A.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_A",500,20,0,0,"PPS:BSYH:1:BTH_TEST_MODE_A") #! Field("PPS:BSYH:1:BTH_TEST_MODE_A.VAL",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi91") { field(DESC, "Port D2_RDA bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HWALRMWARN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HWALRMWARN_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi91 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HWALRMWARN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HWALRMWARN_A") { field(DESC, "HW_Alarm_Warning_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb91",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb91") #! Field("PLC:BSY0:PP05:D2_RDAb91.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb91.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb91.FLNK","PPS:BSYH:1:STD2:HWALRMWARN_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb91.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb91.VAL") #! Record("PPS:BSYH:1:STD2:HWALRMWARN_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:HWALRMWARN_A_calc") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HWALRMWARN_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:HWALRMWARN_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb91.VAL") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HWALRMWARN_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HWALRMWARN_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:HWALRMWARN_A_calc.OUT","PPS:BSYH:1:STD2:HWALRMWARN_A.VAL") #! Record("PPS:BSYH:1:STD2:HWALRMWARN_A",500,20,0,0,"PPS:BSYH:1:STD2:HWALRMWARN_A") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_A.VAL",16777215,1,"PPS:BSYH:1:STD2:HWALRMWARN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi90") { field(DESC, "Port D2_RDA bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_OUTP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_OUTP_A") { field(DESC, "PLC_Heartbeat_Output_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb90",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb90") #! Field("PLC:BSY0:PP05:D2_RDAb90.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb90.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb90.FLNK","PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb90.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb90.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb90.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_OUTP_A_calc.OUT","PPS:BSYH:1:STD2:HRTBT_OUTP_A.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OUTP_A",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_OUTP_A") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_A.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi89") { field(DESC, "Port D2_RDA bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 89, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:2:STD2_IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_IN_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_IN_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_IN_A") { field(DESC, "STD2_In_Sum_Output_To_SR_A") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb89",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb89") #! Field("PLC:BSY0:PP05:D2_RDAb89.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb89.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb89.FLNK","STPR:BSYH:2:STD2_IN_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb89.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb89.VAL") #! Record("STPR:BSYH:2:STD2_IN_A_calc",260,18,0,1,"STPR:BSYH:2:STD2_IN_A_calc") #! Field("STPR:BSYH:2:STD2_IN_A_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_IN_A_calc.INPA") #! Link("STPR:BSYH:2:STD2_IN_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb89.VAL") #! Field("STPR:BSYH:2:STD2_IN_A_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_IN_A_calc.INPB") #! Field("STPR:BSYH:2:STD2_IN_A_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_IN_A_calc.OUT") #! Link("STPR:BSYH:2:STD2_IN_A_calc.OUT","STPR:BSYH:2:STD2_IN_A.VAL") #! Record("STPR:BSYH:2:STD2_IN_A",500,20,0,0,"STPR:BSYH:2:STD2_IN_A") #! Field("STPR:BSYH:2:STD2_IN_A.VAL",16777215,1,"STPR:BSYH:2:STD2_IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi88") { field(DESC, "Port D2_RDA bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 88, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:2:STD2_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_OUT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_OUT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_OUT_A") { field(DESC, "STD2_Out_Sum_Output_To_SR_A") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb88",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb88") #! Field("PLC:BSY0:PP05:D2_RDAb88.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb88.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb88.FLNK","STPR:BSYH:2:STD2_OUT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb88.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb88.VAL") #! Record("STPR:BSYH:2:STD2_OUT_A_calc",260,18,0,1,"STPR:BSYH:2:STD2_OUT_A_calc") #! Field("STPR:BSYH:2:STD2_OUT_A_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_OUT_A_calc.INPA") #! Link("STPR:BSYH:2:STD2_OUT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb88.VAL") #! Field("STPR:BSYH:2:STD2_OUT_A_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_OUT_A_calc.INPB") #! Field("STPR:BSYH:2:STD2_OUT_A_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_OUT_A_calc.OUT") #! Link("STPR:BSYH:2:STD2_OUT_A_calc.OUT","STPR:BSYH:2:STD2_OUT_A.VAL") #! Record("STPR:BSYH:2:STD2_OUT_A",500,20,0,0,"STPR:BSYH:2:STD2_OUT_A") #! Field("STPR:BSYH:2:STD2_OUT_A.VAL",16777215,1,"STPR:BSYH:2:STD2_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi103") { field(DESC, "Port D2_RDA bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:XINTLK_SELF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:XINTLK_SELF_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:XINTLK_SELF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:XINTLK_SELF_A") { field(DESC, "Self_Cross_Intlk_Output_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb103",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb103") #! Field("PLC:BSY0:PP05:D2_RDAb103.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb103.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb103.FLNK","PPS:BSYH:1:STD2:XINTLK_SELF_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb103.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb103.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_SELF_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:XINTLK_SELF_A_calc") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb103.VAL") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:XINTLK_SELF_A_calc.OUT","PPS:BSYH:1:STD2:XINTLK_SELF_A.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_SELF_A",500,20,0,0,"PPS:BSYH:1:STD2:XINTLK_SELF_A") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_A.VAL",16777215,1,"PPS:BSYH:1:STD2:XINTLK_SELF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi102") { field(DESC, "Port D2_RDA bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:XINTLK_OPP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:XINTLK_OPP_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:XINTLK_OPP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:XINTLK_OPP_A") { field(DESC, "Opposite_Cross_Intlk_Output_A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb102",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb102") #! Field("PLC:BSY0:PP05:D2_RDAb102.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb102.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb102.FLNK","PPS:BSYH:1:STD2:XINTLK_OPP_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb102.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb102.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_OPP_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:XINTLK_OPP_A_calc") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb102.VAL") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:XINTLK_OPP_A_calc.OUT","PPS:BSYH:1:STD2:XINTLK_OPP_A.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_OPP_A",500,20,0,0,"PPS:BSYH:1:STD2:XINTLK_OPP_A") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_A.VAL",16777215,1,"PPS:BSYH:1:STD2:XINTLK_OPP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi101") { field(DESC, "Port D2_RDA bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 101, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:BSYH:1:STD2:PERMITTED_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:PERMITTED_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:PERMITTED_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:PERMITTED_A") { field(DESC, "STD2_Permitted_A") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb101",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb101") #! Field("PLC:BSY0:PP05:D2_RDAb101.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb101.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb101.FLNK","PPS:BSYH:1:STD2:PERMITTED_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb101.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb101.VAL") #! Record("PPS:BSYH:1:STD2:PERMITTED_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:PERMITTED_A_calc") #! Field("PPS:BSYH:1:STD2:PERMITTED_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:PERMITTED_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:PERMITTED_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb101.VAL") #! Field("PPS:BSYH:1:STD2:PERMITTED_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:PERMITTED_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:PERMITTED_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:PERMITTED_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:PERMITTED_A_calc.OUT","PPS:BSYH:1:STD2:PERMITTED_A.VAL") #! Record("PPS:BSYH:1:STD2:PERMITTED_A",500,20,0,0,"PPS:BSYH:1:STD2:PERMITTED_A") #! Field("PPS:BSYH:1:STD2:PERMITTED_A.VAL",16777215,1,"PPS:BSYH:1:STD2:PERMITTED_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi100") { field(DESC, "Port D2_RDA bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:BCS_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:BCS_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:BCS_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:BCS_FAULT_A") { field(DESC, "BCS_Fault_from_PLC4A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb100",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb100") #! Field("PLC:BSY0:PP05:D2_RDAb100.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb100.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb100.FLNK","PPS:BSYH:1:STD2:BCS_FAULT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb100.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb100.VAL") #! Record("PPS:BSYH:1:STD2:BCS_FAULT_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:BCS_FAULT_A_calc") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:BCS_FAULT_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:BCS_FAULT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb100.VAL") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:BCS_FAULT_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:BCS_FAULT_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:BCS_FAULT_A_calc.OUT","PPS:BSYH:1:STD2:BCS_FAULT_A.VAL") #! Record("PPS:BSYH:1:STD2:BCS_FAULT_A",500,20,0,0,"PPS:BSYH:1:STD2:BCS_FAULT_A") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_A.VAL",16777215,1,"PPS:BSYH:1:STD2:BCS_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi97") { field(DESC, "Port D2_RDA bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 97, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:847:MOTOR_DRV1_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_DRV1_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_DRV1_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_DRV1_A") { field(DESC, "STD2_Motor_Driver_Control_1_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb97",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb97") #! Field("PLC:BSY0:PP05:D2_RDAb97.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb97.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb97.FLNK","STPR:BSYH:847:MOTOR_DRV1_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb97.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb97.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV1_A_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_DRV1_A_calc") #! Field("STPR:BSYH:847:MOTOR_DRV1_A_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_DRV1_A_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_DRV1_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb97.VAL") #! Field("STPR:BSYH:847:MOTOR_DRV1_A_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_DRV1_A_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_DRV1_A_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_DRV1_A_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_DRV1_A_calc.OUT","STPR:BSYH:847:MOTOR_DRV1_A.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV1_A",500,20,0,0,"STPR:BSYH:847:MOTOR_DRV1_A") #! Field("STPR:BSYH:847:MOTOR_DRV1_A.VAL",16777215,1,"STPR:BSYH:847:MOTOR_DRV1_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi96") { field(DESC, "Port D2_RDA bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 96, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:847:MOTOR_DRV2_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_DRV2_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi96 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_DRV2_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_DRV2_A") { field(DESC, "STD2_Motor_Driver_Control_2_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb96",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb96") #! Field("PLC:BSY0:PP05:D2_RDAb96.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb96.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb96.FLNK","STPR:BSYH:847:MOTOR_DRV2_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb96.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb96.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV2_A_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_DRV2_A_calc") #! Field("STPR:BSYH:847:MOTOR_DRV2_A_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_DRV2_A_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_DRV2_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb96.VAL") #! Field("STPR:BSYH:847:MOTOR_DRV2_A_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_DRV2_A_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_DRV2_A_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_DRV2_A_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_DRV2_A_calc.OUT","STPR:BSYH:847:MOTOR_DRV2_A.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV2_A",500,20,0,0,"STPR:BSYH:847:MOTOR_DRV2_A") #! Field("STPR:BSYH:847:MOTOR_DRV2_A.VAL",16777215,1,"STPR:BSYH:847:MOTOR_DRV2_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi111") { field(DESC, "Port D2_RDA bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 111, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:854:SOLENOID_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:SOLENOID_OUT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:SOLENOID_OUT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:SOLENOID_OUT_A") { field(DESC, "ST60_Solenoid_Air_Out_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb111",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb111") #! Field("PLC:BSY0:PP05:D2_RDAb111.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb111.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb111.FLNK","STPR:BSYH:854:SOLENOID_OUT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb111.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb111.VAL") #! Record("STPR:BSYH:854:SOLENOID_OUT_A_calc",260,18,0,1,"STPR:BSYH:854:SOLENOID_OUT_A_calc") #! Field("STPR:BSYH:854:SOLENOID_OUT_A_calc.INPA",16777215,0,"STPR:BSYH:854:SOLENOID_OUT_A_calc.INPA") #! Link("STPR:BSYH:854:SOLENOID_OUT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb111.VAL") #! Field("STPR:BSYH:854:SOLENOID_OUT_A_calc.INPB",16777215,1,"STPR:BSYH:854:SOLENOID_OUT_A_calc.INPB") #! Field("STPR:BSYH:854:SOLENOID_OUT_A_calc.OUT",16777215,1,"STPR:BSYH:854:SOLENOID_OUT_A_calc.OUT") #! Link("STPR:BSYH:854:SOLENOID_OUT_A_calc.OUT","STPR:BSYH:854:SOLENOID_OUT_A.VAL") #! Record("STPR:BSYH:854:SOLENOID_OUT_A",500,20,0,0,"STPR:BSYH:854:SOLENOID_OUT_A") #! Field("STPR:BSYH:854:SOLENOID_OUT_A.VAL",16777215,1,"STPR:BSYH:854:SOLENOID_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi110") { field(DESC, "Port D2_RDA bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 110, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:854:SOLENOID_RET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:SOLENOID_RET_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:SOLENOID_RET_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:SOLENOID_RET_A") { field(DESC, "ST60_Solenoid_Air_Return_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb110",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb110") #! Field("PLC:BSY0:PP05:D2_RDAb110.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb110.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb110.FLNK","STPR:BSYH:854:SOLENOID_RET_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb110.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb110.VAL") #! Record("STPR:BSYH:854:SOLENOID_RET_A_calc",260,18,0,1,"STPR:BSYH:854:SOLENOID_RET_A_calc") #! Field("STPR:BSYH:854:SOLENOID_RET_A_calc.INPA",16777215,0,"STPR:BSYH:854:SOLENOID_RET_A_calc.INPA") #! Link("STPR:BSYH:854:SOLENOID_RET_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb110.VAL") #! Field("STPR:BSYH:854:SOLENOID_RET_A_calc.INPB",16777215,1,"STPR:BSYH:854:SOLENOID_RET_A_calc.INPB") #! Field("STPR:BSYH:854:SOLENOID_RET_A_calc.OUT",16777215,1,"STPR:BSYH:854:SOLENOID_RET_A_calc.OUT") #! Link("STPR:BSYH:854:SOLENOID_RET_A_calc.OUT","STPR:BSYH:854:SOLENOID_RET_A.VAL") #! Record("STPR:BSYH:854:SOLENOID_RET_A",500,20,0,0,"STPR:BSYH:854:SOLENOID_RET_A") #! Field("STPR:BSYH:854:SOLENOID_RET_A.VAL",16777215,1,"STPR:BSYH:854:SOLENOID_RET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi109") { field(DESC, "Port D2_RDA bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 109, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:905:SOLENOID_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:SOLENOID_OUT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:SOLENOID_OUT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:SOLENOID_OUT_A") { field(DESC, "ST61_Solenoid_Air_Out_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb109",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb109") #! Field("PLC:BSY0:PP05:D2_RDAb109.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb109.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb109.FLNK","STPR:BSYH:905:SOLENOID_OUT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb109.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb109.VAL") #! Record("STPR:BSYH:905:SOLENOID_OUT_A_calc",260,18,0,1,"STPR:BSYH:905:SOLENOID_OUT_A_calc") #! Field("STPR:BSYH:905:SOLENOID_OUT_A_calc.INPA",16777215,0,"STPR:BSYH:905:SOLENOID_OUT_A_calc.INPA") #! Link("STPR:BSYH:905:SOLENOID_OUT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb109.VAL") #! Field("STPR:BSYH:905:SOLENOID_OUT_A_calc.INPB",16777215,1,"STPR:BSYH:905:SOLENOID_OUT_A_calc.INPB") #! Field("STPR:BSYH:905:SOLENOID_OUT_A_calc.OUT",16777215,1,"STPR:BSYH:905:SOLENOID_OUT_A_calc.OUT") #! Link("STPR:BSYH:905:SOLENOID_OUT_A_calc.OUT","STPR:BSYH:905:SOLENOID_OUT_A.VAL") #! Record("STPR:BSYH:905:SOLENOID_OUT_A",500,20,0,0,"STPR:BSYH:905:SOLENOID_OUT_A") #! Field("STPR:BSYH:905:SOLENOID_OUT_A.VAL",16777215,1,"STPR:BSYH:905:SOLENOID_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi108") { field(DESC, "Port D2_RDA bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 108, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:905:SOLENOID_RET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:SOLENOID_RET_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:SOLENOID_RET_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:SOLENOID_RET_A") { field(DESC, "ST61_Solenoid_Air_Return_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb108",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb108") #! Field("PLC:BSY0:PP05:D2_RDAb108.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb108.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb108.FLNK","STPR:BSYH:905:SOLENOID_RET_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb108.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb108.VAL") #! Record("STPR:BSYH:905:SOLENOID_RET_A_calc",260,18,0,1,"STPR:BSYH:905:SOLENOID_RET_A_calc") #! Field("STPR:BSYH:905:SOLENOID_RET_A_calc.INPA",16777215,0,"STPR:BSYH:905:SOLENOID_RET_A_calc.INPA") #! Link("STPR:BSYH:905:SOLENOID_RET_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb108.VAL") #! Field("STPR:BSYH:905:SOLENOID_RET_A_calc.INPB",16777215,1,"STPR:BSYH:905:SOLENOID_RET_A_calc.INPB") #! Field("STPR:BSYH:905:SOLENOID_RET_A_calc.OUT",16777215,1,"STPR:BSYH:905:SOLENOID_RET_A_calc.OUT") #! Link("STPR:BSYH:905:SOLENOID_RET_A_calc.OUT","STPR:BSYH:905:SOLENOID_RET_A.VAL") #! Record("STPR:BSYH:905:SOLENOID_RET_A",500,20,0,0,"STPR:BSYH:905:SOLENOID_RET_A") #! Field("STPR:BSYH:905:SOLENOID_RET_A.VAL",16777215,1,"STPR:BSYH:905:SOLENOID_RET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi107") { field(DESC, "Port D2_RDA bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 107, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "BTM:BSYH:858:SOLENOID_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:SOLENOID_OUT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:SOLENOID_OUT_A PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:SOLENOID_OUT_A") { field(DESC, "DM60_Solenoid_Air_Out_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb107",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb107") #! Field("PLC:BSY0:PP05:D2_RDAb107.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb107.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb107.FLNK","BTM:BSYH:858:SOLENOID_OUT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb107.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb107.VAL") #! Record("BTM:BSYH:858:SOLENOID_OUT_A_calc",260,18,0,1,"BTM:BSYH:858:SOLENOID_OUT_A_calc") #! Field("BTM:BSYH:858:SOLENOID_OUT_A_calc.INPA",16777215,0,"BTM:BSYH:858:SOLENOID_OUT_A_calc.INPA") #! Link("BTM:BSYH:858:SOLENOID_OUT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb107.VAL") #! Field("BTM:BSYH:858:SOLENOID_OUT_A_calc.INPB",16777215,1,"BTM:BSYH:858:SOLENOID_OUT_A_calc.INPB") #! Field("BTM:BSYH:858:SOLENOID_OUT_A_calc.OUT",16777215,1,"BTM:BSYH:858:SOLENOID_OUT_A_calc.OUT") #! Link("BTM:BSYH:858:SOLENOID_OUT_A_calc.OUT","BTM:BSYH:858:SOLENOID_OUT_A.VAL") #! Record("BTM:BSYH:858:SOLENOID_OUT_A",500,20,0,0,"BTM:BSYH:858:SOLENOID_OUT_A") #! Field("BTM:BSYH:858:SOLENOID_OUT_A.VAL",16777215,1,"BTM:BSYH:858:SOLENOID_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi106") { field(DESC, "Port D2_RDA bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 106, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "BTM:BSYH:858:SOLENOID_RET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:SOLENOID_RET_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:SOLENOID_RET_A PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:SOLENOID_RET_A") { field(DESC, "DM60_Solenoid_Air_Return_A") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb106",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb106") #! Field("PLC:BSY0:PP05:D2_RDAb106.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb106.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb106.FLNK","BTM:BSYH:858:SOLENOID_RET_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb106.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb106.VAL") #! Record("BTM:BSYH:858:SOLENOID_RET_A_calc",260,18,0,1,"BTM:BSYH:858:SOLENOID_RET_A_calc") #! Field("BTM:BSYH:858:SOLENOID_RET_A_calc.INPA",16777215,0,"BTM:BSYH:858:SOLENOID_RET_A_calc.INPA") #! Link("BTM:BSYH:858:SOLENOID_RET_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb106.VAL") #! Field("BTM:BSYH:858:SOLENOID_RET_A_calc.INPB",16777215,1,"BTM:BSYH:858:SOLENOID_RET_A_calc.INPB") #! Field("BTM:BSYH:858:SOLENOID_RET_A_calc.OUT",16777215,1,"BTM:BSYH:858:SOLENOID_RET_A_calc.OUT") #! Link("BTM:BSYH:858:SOLENOID_RET_A_calc.OUT","BTM:BSYH:858:SOLENOID_RET_A.VAL") #! Record("BTM:BSYH:858:SOLENOID_RET_A",500,20,0,0,"BTM:BSYH:858:SOLENOID_RET_A") #! Field("BTM:BSYH:858:SOLENOID_RET_A.VAL",16777215,1,"BTM:BSYH:858:SOLENOID_RET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi105") { field(DESC, "Port D2_RDA bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 105, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A") { field(DESC, "LCLS Secure Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb105",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb105") #! Field("PLC:BSY0:PP05:D2_RDAb105.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb105.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb105.FLNK","PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb105.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb105.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb105.VAL") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A_calc.OUT","PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi104") { field(DESC, "Port D2_RDA bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 104, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A") { field(DESC, "BSOICs Grp. C OK Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb104",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb104") #! Field("PLC:BSY0:PP05:D2_RDAb104.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb104.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb104.FLNK","PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb104.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb104.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb104.VAL") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A_calc.OUT","PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi119") { field(DESC, "Port D2_RDA bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 119, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICK_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICK_OFF_LTH_A") { field(DESC, "HXR_Kicker_Off_Sum_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb119",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb119") #! Field("PLC:BSY0:PP05:D2_RDAb119.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb119.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb119.FLNK","PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb119.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb119.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc",260,18,0,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.INPA") #! Link("PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb119.VAL") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.INPB") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.OUT") #! Link("PPS:LI28:1:HXR:KICK_OFF_LTH_A_calc.OUT","PPS:LI28:1:HXR:KICK_OFF_LTH_A.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_LTH_A",500,20,0,0,"PPS:LI28:1:HXR:KICK_OFF_LTH_A") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_A.VAL",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi118") { field(DESC, "Port D2_RDA bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 118, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi118 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_A") { field(DESC, "Generic_D2_Interlock_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb118",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb118") #! Field("PLC:BSY0:PP05:D2_RDAb118.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb118.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb118.FLNK","PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb118.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb118.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb118.VAL") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A_calc.OUT","PPS:BSYH:1:STD2:GEN_INTLK_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_A") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi117") { field(DESC, "Port D2_RDA bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 117, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi117 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_A") { field(DESC, "PLC4_Enable_Keysw_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb117",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb117") #! Field("PLC:BSY0:PP05:D2_RDAb117.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb117.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb117.FLNK","PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb117.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb117.VAL") #! Record("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb117.VAL") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A_calc.OUT","PPS:BSYH:1:STD2:STOP_ENBL_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_A") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi116") { field(DESC, "Port D2_RDA bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_A") { field(DESC, "STD2_Admin_Enable_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb116",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb116") #! Field("PLC:BSY0:PP05:D2_RDAb116.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb116.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb116.FLNK","PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb116.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb116.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb116.VAL") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A_calc.OUT","PPS:BSYH:1:STD2_ADMIN_EN_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_A") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi115") { field(DESC, "Port D2_RDA bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_A") { field(DESC, "STD2_Motor_Power_OK_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb115",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb115") #! Field("PLC:BSY0:PP05:D2_RDAb115.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb115.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb115.FLNK","STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb115.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb115.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb115.VAL") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A_calc.OUT","STPR:BSYH:847:MOTOR_PWR_OK_LTH_A.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A",500,20,0,0,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_A") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_A.VAL",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi114") { field(DESC, "Port D2_RDA bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:BTH_TEST_MODE_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:BTH_TEST_MODE_LTH_A") { field(DESC, "BTH_In_Test_Mode_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb114",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb114") #! Field("PLC:BSY0:PP05:D2_RDAb114.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb114.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb114.FLNK","PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb114.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb114.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb114.VAL") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:BTH_TEST_MODE_LTH_A_calc.OUT","PPS:BSYH:1:BTH_TEST_MODE_LTH_A.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_LTH_A",500,20,0,0,"PPS:BSYH:1:BTH_TEST_MODE_LTH_A") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_A.VAL",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi113") { field(DESC, "Port D2_RDA bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_A") { field(DESC, "Heartbeats_Ok_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb113",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb113") #! Field("PLC:BSY0:PP05:D2_RDAb113.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb113.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb113.FLNK","PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb113.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb113.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb113.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A_calc.OUT","PPS:BSYH:1:STD2:HRTBT_OK_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_A") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi127") { field(DESC, "Port D2_RDA bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 127, 1, 1)") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_OK_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_OK_A") { field(DESC, "Heartbeat OK A") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb127",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb127") #! Field("PLC:BSY0:PP05:D2_RDAb127.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb127.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb127.FLNK","PPS:BSYH:1:STD2:HRTBT_OK_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb127.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb127.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_OK_A_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_OK_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb127.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_A_calc.OUT","PPS:BSYH:1:STD2:HRTBT_OK_A.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_A",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_OK_A") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_A.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi123") { field(DESC, "Port D2_RDA bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 123, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:2:STD2_IN_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_IN_LAT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_IN_LAT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_IN_LAT_A") { field(DESC, "STD2_In_Sum_Out_To_SR_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb123",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb123") #! Field("PLC:BSY0:PP05:D2_RDAb123.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb123.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb123.FLNK","STPR:BSYH:2:STD2_IN_LAT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb123.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb123.VAL") #! Record("STPR:BSYH:2:STD2_IN_LAT_A_calc",260,18,0,1,"STPR:BSYH:2:STD2_IN_LAT_A_calc") #! Field("STPR:BSYH:2:STD2_IN_LAT_A_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_IN_LAT_A_calc.INPA") #! Link("STPR:BSYH:2:STD2_IN_LAT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb123.VAL") #! Field("STPR:BSYH:2:STD2_IN_LAT_A_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_IN_LAT_A_calc.INPB") #! Field("STPR:BSYH:2:STD2_IN_LAT_A_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_IN_LAT_A_calc.OUT") #! Link("STPR:BSYH:2:STD2_IN_LAT_A_calc.OUT","STPR:BSYH:2:STD2_IN_LAT_A.VAL") #! Record("STPR:BSYH:2:STD2_IN_LAT_A",500,20,0,0,"STPR:BSYH:2:STD2_IN_LAT_A") #! Field("STPR:BSYH:2:STD2_IN_LAT_A.VAL",16777215,1,"STPR:BSYH:2:STD2_IN_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi122") { field(DESC, "Port D2_RDA bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 122, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:2:STD2_OUT_LAT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_OUT_LAT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi122 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_OUT_LAT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_OUT_LAT_A") { field(DESC, "STD2_Out_Sum_Out_To_SR_Lat_A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb122",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb122") #! Field("PLC:BSY0:PP05:D2_RDAb122.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb122.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb122.FLNK","STPR:BSYH:2:STD2_OUT_LAT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb122.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb122.VAL") #! Record("STPR:BSYH:2:STD2_OUT_LAT_A_calc",260,18,0,1,"STPR:BSYH:2:STD2_OUT_LAT_A_calc") #! Field("STPR:BSYH:2:STD2_OUT_LAT_A_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_OUT_LAT_A_calc.INPA") #! Link("STPR:BSYH:2:STD2_OUT_LAT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb122.VAL") #! Field("STPR:BSYH:2:STD2_OUT_LAT_A_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_OUT_LAT_A_calc.INPB") #! Field("STPR:BSYH:2:STD2_OUT_LAT_A_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_OUT_LAT_A_calc.OUT") #! Link("STPR:BSYH:2:STD2_OUT_LAT_A_calc.OUT","STPR:BSYH:2:STD2_OUT_LAT_A.VAL") #! Record("STPR:BSYH:2:STD2_OUT_LAT_A",500,20,0,0,"STPR:BSYH:2:STD2_OUT_LAT_A") #! Field("STPR:BSYH:2:STD2_OUT_LAT_A.VAL",16777215,1,"STPR:BSYH:2:STD2_OUT_LAT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi121") { field(DESC, "Port D2_RDA bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 121, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYH:1:STD2:STOP_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOP_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOP_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOP_FAULT_A") { field(DESC, "D2 Stopper Fault A") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb121",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb121") #! Field("PLC:BSY0:PP05:D2_RDAb121.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb121.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb121.FLNK","PPS:BSYH:1:STD2:STOP_FAULT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb121.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb121.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOP_FAULT_A_calc") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOP_FAULT_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb121.VAL") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_A_calc.OUT","PPS:BSYH:1:STD2:STOP_FAULT_A.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_A",500,20,0,0,"PPS:BSYH:1:STD2:STOP_FAULT_A") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_A.VAL",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi120") { field(DESC, "Port D2_RDA bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 120, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "STPR:BSYH:854:STOP_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:STOP_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:STOP_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:STOP_FAULT_A") { field(DESC, "ST60 Stopper Fault A") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb120",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb120") #! Field("PLC:BSY0:PP05:D2_RDAb120.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb120.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb120.FLNK","STPR:BSYH:854:STOP_FAULT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb120.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb120.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_A_calc",260,18,0,1,"STPR:BSYH:854:STOP_FAULT_A_calc") #! Field("STPR:BSYH:854:STOP_FAULT_A_calc.INPA",16777215,0,"STPR:BSYH:854:STOP_FAULT_A_calc.INPA") #! Link("STPR:BSYH:854:STOP_FAULT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb120.VAL") #! Field("STPR:BSYH:854:STOP_FAULT_A_calc.INPB",16777215,1,"STPR:BSYH:854:STOP_FAULT_A_calc.INPB") #! Field("STPR:BSYH:854:STOP_FAULT_A_calc.OUT",16777215,1,"STPR:BSYH:854:STOP_FAULT_A_calc.OUT") #! Link("STPR:BSYH:854:STOP_FAULT_A_calc.OUT","STPR:BSYH:854:STOP_FAULT_A.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_A",500,20,0,0,"STPR:BSYH:854:STOP_FAULT_A") #! Field("STPR:BSYH:854:STOP_FAULT_A.VAL",16777215,1,"STPR:BSYH:854:STOP_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi135") { field(DESC, "Port D2_RDA bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 135, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "STPR:BSYH:905:STOP_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:STOP_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:STOP_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:STOP_FAULT_A") { field(DESC, "ST61 Stopper Fault A") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb135",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb135") #! Field("PLC:BSY0:PP05:D2_RDAb135.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb135.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb135.FLNK","STPR:BSYH:905:STOP_FAULT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb135.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb135.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_A_calc",260,18,0,1,"STPR:BSYH:905:STOP_FAULT_A_calc") #! Field("STPR:BSYH:905:STOP_FAULT_A_calc.INPA",16777215,0,"STPR:BSYH:905:STOP_FAULT_A_calc.INPA") #! Link("STPR:BSYH:905:STOP_FAULT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb135.VAL") #! Field("STPR:BSYH:905:STOP_FAULT_A_calc.INPB",16777215,1,"STPR:BSYH:905:STOP_FAULT_A_calc.INPB") #! Field("STPR:BSYH:905:STOP_FAULT_A_calc.OUT",16777215,1,"STPR:BSYH:905:STOP_FAULT_A_calc.OUT") #! Link("STPR:BSYH:905:STOP_FAULT_A_calc.OUT","STPR:BSYH:905:STOP_FAULT_A.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_A",500,20,0,0,"STPR:BSYH:905:STOP_FAULT_A") #! Field("STPR:BSYH:905:STOP_FAULT_A.VAL",16777215,1,"STPR:BSYH:905:STOP_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi134") { field(DESC, "Port D2_RDA bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 134, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BTM:BSYH:858:STOP_FAULT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:STOP_FAULT_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:STOP_FAULT_A PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:STOP_FAULT_A") { field(DESC, "DM60 Stopper Fault A") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb134",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb134") #! Field("PLC:BSY0:PP05:D2_RDAb134.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb134.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb134.FLNK","BTM:BSYH:858:STOP_FAULT_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb134.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb134.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_A_calc",260,18,0,1,"BTM:BSYH:858:STOP_FAULT_A_calc") #! Field("BTM:BSYH:858:STOP_FAULT_A_calc.INPA",16777215,0,"BTM:BSYH:858:STOP_FAULT_A_calc.INPA") #! Link("BTM:BSYH:858:STOP_FAULT_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb134.VAL") #! Field("BTM:BSYH:858:STOP_FAULT_A_calc.INPB",16777215,1,"BTM:BSYH:858:STOP_FAULT_A_calc.INPB") #! Field("BTM:BSYH:858:STOP_FAULT_A_calc.OUT",16777215,1,"BTM:BSYH:858:STOP_FAULT_A_calc.OUT") #! Link("BTM:BSYH:858:STOP_FAULT_A_calc.OUT","BTM:BSYH:858:STOP_FAULT_A.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_A",500,20,0,0,"BTM:BSYH:858:STOP_FAULT_A") #! Field("BTM:BSYH:858:STOP_FAULT_A.VAL",16777215,1,"BTM:BSYH:858:STOP_FAULT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi133") { field(DESC, "Port D2_RDA bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 133, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYH:1:SR_STD2_IN_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_IN_OK_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_IN_OK_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_IN_OK_A") { field(DESC, "Safety Relay D2 IN OK A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb133",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb133") #! Field("PLC:BSY0:PP05:D2_RDAb133.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb133.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb133.FLNK","STPR:BSYH:1:SR_STD2_IN_OK_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb133.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb133.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_A_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_IN_OK_A_calc") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_A_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_IN_OK_A_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb133.VAL") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_A_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_A_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_A_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_A_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_A_calc.OUT","STPR:BSYH:1:SR_STD2_IN_OK_A.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_A",500,20,0,0,"STPR:BSYH:1:SR_STD2_IN_OK_A") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_A.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi132") { field(DESC, "Port D2_RDA bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 132, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYH:1:SR_STD2_OUT_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_OUT_OK_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_OUT_OK_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_OUT_OK_A") { field(DESC, "Safety Relay D2 OUT OK A") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb132",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb132") #! Field("PLC:BSY0:PP05:D2_RDAb132.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb132.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb132.FLNK","STPR:BSYH:1:SR_STD2_OUT_OK_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb132.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb132.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_A_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_OUT_OK_A_calc") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb132.VAL") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_A_calc.OUT","STPR:BSYH:1:SR_STD2_OUT_OK_A.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_A",500,20,0,0,"STPR:BSYH:1:SR_STD2_OUT_OK_A") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_A.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi143") { field(DESC, "Port D2_RDA bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 143, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_A") { field(DESC, "D2 Stopper Fault Lat A") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb143",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb143") #! Field("PLC:BSY0:PP05:D2_RDAb143.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb143.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb143.FLNK","PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb143.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb143.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb143.VAL") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A_calc.OUT","PPS:BSYH:1:STD2:STOP_FAULT_LTH_A.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A",500,20,0,0,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_A") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_A.VAL",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi142") { field(DESC, "Port D2_RDA bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 142, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "STPR:BSYH:854:STOP_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:STOP_FAULT_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:STOP_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:STOP_FAULT_LTH_A") { field(DESC, "ST60 Stopper Fault Lat A") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb142",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb142") #! Field("PLC:BSY0:PP05:D2_RDAb142.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb142.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb142.FLNK","STPR:BSYH:854:STOP_FAULT_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb142.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb142.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_LTH_A_calc",260,18,0,1,"STPR:BSYH:854:STOP_FAULT_LTH_A_calc") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_A_calc.INPA",16777215,0,"STPR:BSYH:854:STOP_FAULT_LTH_A_calc.INPA") #! Link("STPR:BSYH:854:STOP_FAULT_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb142.VAL") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_A_calc.INPB",16777215,1,"STPR:BSYH:854:STOP_FAULT_LTH_A_calc.INPB") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_A_calc.OUT",16777215,1,"STPR:BSYH:854:STOP_FAULT_LTH_A_calc.OUT") #! Link("STPR:BSYH:854:STOP_FAULT_LTH_A_calc.OUT","STPR:BSYH:854:STOP_FAULT_LTH_A.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_LTH_A",500,20,0,0,"STPR:BSYH:854:STOP_FAULT_LTH_A") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_A.VAL",16777215,1,"STPR:BSYH:854:STOP_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi141") { field(DESC, "Port D2_RDA bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 141, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "STPR:BSYH:905:STOP_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:STOP_FAULT_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:STOP_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:STOP_FAULT_LTH_A") { field(DESC, "ST61 Stopper Fault Lat A") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb141",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb141") #! Field("PLC:BSY0:PP05:D2_RDAb141.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb141.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb141.FLNK","STPR:BSYH:905:STOP_FAULT_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb141.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb141.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_LTH_A_calc",260,18,0,1,"STPR:BSYH:905:STOP_FAULT_LTH_A_calc") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_A_calc.INPA",16777215,0,"STPR:BSYH:905:STOP_FAULT_LTH_A_calc.INPA") #! Link("STPR:BSYH:905:STOP_FAULT_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb141.VAL") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_A_calc.INPB",16777215,1,"STPR:BSYH:905:STOP_FAULT_LTH_A_calc.INPB") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_A_calc.OUT",16777215,1,"STPR:BSYH:905:STOP_FAULT_LTH_A_calc.OUT") #! Link("STPR:BSYH:905:STOP_FAULT_LTH_A_calc.OUT","STPR:BSYH:905:STOP_FAULT_LTH_A.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_LTH_A",500,20,0,0,"STPR:BSYH:905:STOP_FAULT_LTH_A") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_A.VAL",16777215,1,"STPR:BSYH:905:STOP_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi140") { field(DESC, "Port D2_RDA bit 140") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 140, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "BTM:BSYH:858:STOP_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:STOP_FAULT_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi140 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:STOP_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:STOP_FAULT_LTH_A") { field(DESC, "DM60 Stopper Fault Lat A") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb140",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb140") #! Field("PLC:BSY0:PP05:D2_RDAb140.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb140.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb140.FLNK","BTM:BSYH:858:STOP_FAULT_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb140.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb140.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_LTH_A_calc",260,18,0,1,"BTM:BSYH:858:STOP_FAULT_LTH_A_calc") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_A_calc.INPA",16777215,0,"BTM:BSYH:858:STOP_FAULT_LTH_A_calc.INPA") #! Link("BTM:BSYH:858:STOP_FAULT_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb140.VAL") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_A_calc.INPB",16777215,1,"BTM:BSYH:858:STOP_FAULT_LTH_A_calc.INPB") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_A_calc.OUT",16777215,1,"BTM:BSYH:858:STOP_FAULT_LTH_A_calc.OUT") #! Link("BTM:BSYH:858:STOP_FAULT_LTH_A_calc.OUT","BTM:BSYH:858:STOP_FAULT_LTH_A.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_LTH_A",500,20,0,0,"BTM:BSYH:858:STOP_FAULT_LTH_A") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_A.VAL",16777215,1,"BTM:BSYH:858:STOP_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi139") { field(DESC, "Port D2_RDA bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 139, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_A") { field(DESC, "Safety Relay D2 IN OK Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb139",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb139") #! Field("PLC:BSY0:PP05:D2_RDAb139.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb139.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb139.FLNK","STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb139.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb139.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb139.VAL") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A_calc.OUT","STPR:BSYH:1:SR_STD2_IN_OK_LTH_A.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A",500,20,0,0,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_A") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_A.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP05:Bi138") { field(DESC, "Port D2_RDA bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc") { field(INPA, "PLC:BSY0:PP05:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP05:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A") { field(DESC, "Safety Relay D2 OUT OK Lat A") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP05:D2_RDAb138",20,19,0,0,"PLC:BSY0:PP05:D2_RDAb138") #! Field("PLC:BSY0:PP05:D2_RDAb138.FLNK",16777215,1,"PLC:BSY0:PP05:D2_RDAb138.FLNK") #! Link("PLC:BSY0:PP05:D2_RDAb138.FLNK","STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc") #! Field("PLC:BSY0:PP05:D2_RDAb138.VAL",16777215,0,"PLC:BSY0:PP05:D2_RDAb138.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.INPA","PLC:BSY0:PP05:D2_RDAb138.VAL") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A_calc.OUT","STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A",500,20,0,0,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_A.VAL") record(bo, "PPS:BSYH:1:STD2:RESET_INTLK_A") { field(DESC, "STD2_Interlock_Reset_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STD2:PAUSEHB_A") { field(DESC, "STD2_Pause_Heartbeat_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STPRBTHINSET_A") { field(DESC, "Send_STD2_Set_In_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 5, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STPRBTHOUTST_A") { field(DESC, "Send_STD2_Set_Out_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 4, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP05:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP05:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP05:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP05:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP05:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP05:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP05:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP05:REQ_SEG CP") field( INPC, "PLC:BSY0:PP05:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP05:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP05:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP05:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP05:REQ_SEG CP") field( INPC, "PLC:BSY0:PP05:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP05:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP05:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP05:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP05:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP05:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP05:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP05:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP05:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP05:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP05:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP05:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP05:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP05:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP05:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP05:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP05:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP05:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP05:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP05:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP05:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP05:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP05:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP05:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP05:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP05:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP05:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP05:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP05:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP05:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP05:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP05:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP05:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP05:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP05:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP05:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP05:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP05:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP05:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP05:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP05:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP05:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP05:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP05:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP05:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP05:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP05:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP05:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP05:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP05:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP05:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP05:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP05:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP05:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP05:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP05:w0") { field(DESC, "D2 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:w1") { field(DESC, "D2 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP05:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP05:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP05:w3") { field(DESC, "D2 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP05:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP05:w3 PP MS") field(INPB, "PLC:BSY0:PP05:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP05:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP05:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP05:w4") { field(DESC, "D2 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP05:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP05:w4 NPP MS") field(INPB, "PLC:BSY0:PP05:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP05:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP05:w5") { field(DESC, "D2 PLC Checksum CHA") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP05:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP05:w5 NPP MS") field(INPB, "PLC:BSY0:PP05:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP05:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP05:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP05:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP05:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP05:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP05:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP05:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP05:w6 NPP MS") field(INPB, "PLC:BSY0:PP05:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP05:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP05:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP05:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP05:w7 NPP MS") field(INPB, "PLC:BSY0:PP05:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP05:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDA, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP05:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP05:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP05:w8 NPP MS") field(INPB, "PLC:BSY0:PP05:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP05:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP05:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP05:OP_HOURS") { field(INPA, "PLC:BSY0:PP05:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP05:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP05:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP05:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP05:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(D2_RDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP05:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP05:RDHist.PROC") } record(waveform,"PLC:BSY0:PP05:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_RDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP05:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP05:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_RDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP05:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP05:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(D2_RDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP05:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP05:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP05:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP05:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP05:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP05:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP05:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP05:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP05:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP05:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(D2_WRTA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP05:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP05:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP05:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WRTA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP05:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP05:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WRTA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP05:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP05:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(D2_WRTA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP05:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTA 0)READ_OK") field(FLNK,"PLC:BSY0:PP05:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP05:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP05:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP05:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP05:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP05:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP05:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP05:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP05:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(D2_WDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP05:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP05:WDHist.PROC") } record(waveform,"PLC:BSY0:PP05:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP05:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP05:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP05:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP05:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(D2_WDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP05:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDA 0)READ_OK") field(FLNK,"PLC:BSY0:PP05:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP05:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDA 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP05:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP05:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDA 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP05:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP05:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDA 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP05:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP05:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDA 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi7") { field(DESC, "Port D2_RDB bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYH:1:STD2:HW_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HW_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi7 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HW_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HW_ENABLE_B") { field(DESC, "D2_HW_Enable_B") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb7",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb7") #! Field("PLC:BSY0:PP06:D2_RDBb7.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb7.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb7.FLNK","PPS:BSYH:1:STD2:HW_ENABLE_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb7.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb7.VAL") #! Record("PPS:BSYH:1:STD2:HW_ENABLE_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:HW_ENABLE_B_calc") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HW_ENABLE_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:HW_ENABLE_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb7.VAL") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HW_ENABLE_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HW_ENABLE_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:HW_ENABLE_B_calc.OUT","PPS:BSYH:1:STD2:HW_ENABLE_B.VAL") #! Record("PPS:BSYH:1:STD2:HW_ENABLE_B",500,20,0,0,"PPS:BSYH:1:STD2:HW_ENABLE_B") #! Field("PPS:BSYH:1:STD2:HW_ENABLE_B.VAL",16777215,1,"PPS:BSYH:1:STD2:HW_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi6") { field(DESC, "Port D2_RDB bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 6, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:XINTLK_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:XINTLK_IN_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi6 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:XINTLK_IN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:XINTLK_IN_B") { field(DESC, "Cross_Intlk_Input_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb6",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb6") #! Field("PLC:BSY0:PP06:D2_RDBb6.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb6.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb6.FLNK","PPS:BSYH:1:STD2:XINTLK_IN_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb6.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb6.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_IN_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:XINTLK_IN_B_calc") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:XINTLK_IN_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:XINTLK_IN_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb6.VAL") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:XINTLK_IN_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:XINTLK_IN_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:XINTLK_IN_B_calc.OUT","PPS:BSYH:1:STD2:XINTLK_IN_B.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_IN_B",500,20,0,0,"PPS:BSYH:1:STD2:XINTLK_IN_B") #! Field("PPS:BSYH:1:STD2:XINTLK_IN_B.VAL",16777215,1,"PPS:BSYH:1:STD2:XINTLK_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi5") { field(DESC, "Port D2_RDB bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 5, 1, 1)") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(FLNK, "PPS:BSYH:1:STD2:LCLS_SECURE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:LCLS_SECURE_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi5 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:LCLS_SECURE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:LCLS_SECURE_B") { field(DESC, "LCLS Secure B") field(ZNAM, "Not_Secure") field(ONAM, "Secure") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb5",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb5") #! Field("PLC:BSY0:PP06:D2_RDBb5.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb5.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb5.FLNK","PPS:BSYH:1:STD2:LCLS_SECURE_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb5.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb5.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:LCLS_SECURE_B_calc") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb5.VAL") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_B_calc.OUT","PPS:BSYH:1:STD2:LCLS_SECURE_B.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_B",500,20,0,0,"PPS:BSYH:1:STD2:LCLS_SECURE_B") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_B.VAL",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi4") { field(DESC, "Port D2_RDB bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 4, 1, 1)") field(ZNAM, "Not_OK") field(ONAM, "OK") field(FLNK, "PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi4 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:BSOICS_C_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:BSOICS_C_OK_B") { field(DESC, "BSOICs Grp. C OK B") field(ZNAM, "Not_OK") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb4",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb4") #! Field("PLC:BSY0:PP06:D2_RDBb4.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb4.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb4.FLNK","PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb4.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb4.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb4.VAL") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_B_calc.OUT","PPS:BSYH:1:STD2:BSOICS_C_OK_B.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_B",500,20,0,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_B") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_B.VAL",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi2") { field(DESC, "Port D2_RDB bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 2, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI28:1:HXR:KICK_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICK_OFF_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi2 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICK_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICK_OFF_B") { field(DESC, "HXR_Kicker_Off_Sum_B") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb2",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb2") #! Field("PLC:BSY0:PP06:D2_RDBb2.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb2.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb2.FLNK","PPS:LI28:1:HXR:KICK_OFF_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb2.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb2.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_B_calc",260,18,0,1,"PPS:LI28:1:HXR:KICK_OFF_B_calc") #! Field("PPS:LI28:1:HXR:KICK_OFF_B_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICK_OFF_B_calc.INPA") #! Link("PPS:LI28:1:HXR:KICK_OFF_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb2.VAL") #! Field("PPS:LI28:1:HXR:KICK_OFF_B_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_B_calc.INPB") #! Field("PPS:LI28:1:HXR:KICK_OFF_B_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_B_calc.OUT") #! Link("PPS:LI28:1:HXR:KICK_OFF_B_calc.OUT","PPS:LI28:1:HXR:KICK_OFF_B.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_B",500,20,0,0,"PPS:LI28:1:HXR:KICK_OFF_B") #! Field("PPS:LI28:1:HXR:KICK_OFF_B.VAL",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi1") { field(DESC, "Port D2_RDB bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 1, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:BSYH:1:STD2:GEN_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:GEN_INTLK_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi1 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:GEN_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:GEN_INTLK_B") { field(DESC, "Generic_D2_Interlock_B") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb1",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb1") #! Field("PLC:BSY0:PP06:D2_RDBb1.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb1.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb1.FLNK","PPS:BSYH:1:STD2:GEN_INTLK_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb1.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb1.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:GEN_INTLK_B_calc") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:GEN_INTLK_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb1.VAL") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_B_calc.OUT","PPS:BSYH:1:STD2:GEN_INTLK_B.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_B",500,20,0,0,"PPS:BSYH:1:STD2:GEN_INTLK_B") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_B.VAL",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi0") { field(DESC, "Port D2_RDB bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 0, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYH:1:STD2:TEST_MODE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:TEST_MODE_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi0 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:TEST_MODE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:TEST_MODE_B") { field(DESC, "D2_Test_Keysw_Status_B") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb0",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb0") #! Field("PLC:BSY0:PP06:D2_RDBb0.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb0.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb0.FLNK","PPS:BSYH:1:STD2:TEST_MODE_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb0.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb0.VAL") #! Record("PPS:BSYH:1:STD2:TEST_MODE_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:TEST_MODE_B_calc") #! Field("PPS:BSYH:1:STD2:TEST_MODE_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:TEST_MODE_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:TEST_MODE_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb0.VAL") #! Field("PPS:BSYH:1:STD2:TEST_MODE_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:TEST_MODE_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:TEST_MODE_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:TEST_MODE_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:TEST_MODE_B_calc.OUT","PPS:BSYH:1:STD2:TEST_MODE_B.VAL") #! Record("PPS:BSYH:1:STD2:TEST_MODE_B",500,20,0,0,"PPS:BSYH:1:STD2:TEST_MODE_B") #! Field("PPS:BSYH:1:STD2:TEST_MODE_B.VAL",16777215,1,"PPS:BSYH:1:STD2:TEST_MODE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi15") { field(DESC, "Port D2_RDB bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_INP_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi15 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_INP_B") { field(DESC, "Heartbeat In (from other chn.)") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb15",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb15") #! Field("PLC:BSY0:PP06:D2_RDBb15.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb15.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb15.FLNK","PPS:BSYH:1:STD2:HRTBT_INP_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb15.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb15.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_INP_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_INP_B_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_INP_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_INP_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb15.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_INP_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_INP_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_INP_B_calc.OUT","PPS:BSYH:1:STD2:HRTBT_INP_B.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_INP_B",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_INP_B") #! Field("PPS:BSYH:1:STD2:HRTBT_INP_B.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi14") { field(DESC, "Port D2_RDB bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 14, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi14 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOPPER_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOPPER_ENABLE_B") { field(DESC, "Local_STD2_Enable_Keysw_B") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb14",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb14") #! Field("PLC:BSY0:PP06:D2_RDBb14.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb14.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb14.FLNK","PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb14.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb14.VAL") #! Record("PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb14.VAL") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOPPER_ENABLE_B_calc.OUT","PPS:BSYH:1:STD2:STOPPER_ENABLE_B.VAL") #! Record("PPS:BSYH:1:STD2:STOPPER_ENABLE_B",500,20,0,0,"PPS:BSYH:1:STD2:STOPPER_ENABLE_B") #! Field("PPS:BSYH:1:STD2:STOPPER_ENABLE_B.VAL",16777215,1,"PPS:BSYH:1:STD2:STOPPER_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi13") { field(DESC, "Port D2_RDB bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 13, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:847:INB_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:INB_calc") { field(INPA, "PLC:BSY0:PP06:Bi13 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:INB PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:INB") { field(DESC, "STD2_IN_Limit_Switch_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb13",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb13") #! Field("PLC:BSY0:PP06:D2_RDBb13.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb13.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb13.FLNK","STPR:BSYH:847:INB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb13.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb13.VAL") #! Record("STPR:BSYH:847:INB_calc",260,18,0,1,"STPR:BSYH:847:INB_calc") #! Field("STPR:BSYH:847:INB_calc.INPA",16777215,0,"STPR:BSYH:847:INB_calc.INPA") #! Link("STPR:BSYH:847:INB_calc.INPA","PLC:BSY0:PP06:D2_RDBb13.VAL") #! Field("STPR:BSYH:847:INB_calc.INPB",16777215,1,"STPR:BSYH:847:INB_calc.INPB") #! Field("STPR:BSYH:847:INB_calc.OUT",16777215,1,"STPR:BSYH:847:INB_calc.OUT") #! Link("STPR:BSYH:847:INB_calc.OUT","STPR:BSYH:847:INB.VAL") #! Record("STPR:BSYH:847:INB",500,20,0,0,"STPR:BSYH:847:INB") #! Field("STPR:BSYH:847:INB.VAL",16777215,1,"STPR:BSYH:847:INB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi12") { field(DESC, "Port D2_RDB bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 12, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:847:OUTB_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:OUTB_calc") { field(INPA, "PLC:BSY0:PP06:Bi12 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:OUTB PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:OUTB") { field(DESC, "STD2_OUT_Limit_Switch_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb12",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb12") #! Field("PLC:BSY0:PP06:D2_RDBb12.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb12.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb12.FLNK","STPR:BSYH:847:OUTB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb12.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb12.VAL") #! Record("STPR:BSYH:847:OUTB_calc",260,18,0,1,"STPR:BSYH:847:OUTB_calc") #! Field("STPR:BSYH:847:OUTB_calc.INPA",16777215,0,"STPR:BSYH:847:OUTB_calc.INPA") #! Link("STPR:BSYH:847:OUTB_calc.INPA","PLC:BSY0:PP06:D2_RDBb12.VAL") #! Field("STPR:BSYH:847:OUTB_calc.INPB",16777215,1,"STPR:BSYH:847:OUTB_calc.INPB") #! Field("STPR:BSYH:847:OUTB_calc.OUT",16777215,1,"STPR:BSYH:847:OUTB_calc.OUT") #! Link("STPR:BSYH:847:OUTB_calc.OUT","STPR:BSYH:847:OUTB.VAL") #! Record("STPR:BSYH:847:OUTB",500,20,0,0,"STPR:BSYH:847:OUTB") #! Field("STPR:BSYH:847:OUTB.VAL",16777215,1,"STPR:BSYH:847:OUTB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi11") { field(DESC, "Port D2_RDB bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 11, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:854:INB_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:INB_calc") { field(INPA, "PLC:BSY0:PP06:Bi11 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:INB PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:INB") { field(DESC, "ST60_IN_Limit_Switch_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb11",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb11") #! Field("PLC:BSY0:PP06:D2_RDBb11.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb11.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb11.FLNK","STPR:BSYH:854:INB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb11.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb11.VAL") #! Record("STPR:BSYH:854:INB_calc",260,18,0,1,"STPR:BSYH:854:INB_calc") #! Field("STPR:BSYH:854:INB_calc.INPA",16777215,0,"STPR:BSYH:854:INB_calc.INPA") #! Link("STPR:BSYH:854:INB_calc.INPA","PLC:BSY0:PP06:D2_RDBb11.VAL") #! Field("STPR:BSYH:854:INB_calc.INPB",16777215,1,"STPR:BSYH:854:INB_calc.INPB") #! Field("STPR:BSYH:854:INB_calc.OUT",16777215,1,"STPR:BSYH:854:INB_calc.OUT") #! Link("STPR:BSYH:854:INB_calc.OUT","STPR:BSYH:854:INB.VAL") #! Record("STPR:BSYH:854:INB",500,20,0,0,"STPR:BSYH:854:INB") #! Field("STPR:BSYH:854:INB.VAL",16777215,1,"STPR:BSYH:854:INB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi10") { field(DESC, "Port D2_RDB bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 10, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:854:OUTB_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:OUTB_calc") { field(INPA, "PLC:BSY0:PP06:Bi10 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:OUTB PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:OUTB") { field(DESC, "ST60_OUT_Limit_Switch_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb10",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb10") #! Field("PLC:BSY0:PP06:D2_RDBb10.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb10.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb10.FLNK","STPR:BSYH:854:OUTB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb10.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb10.VAL") #! Record("STPR:BSYH:854:OUTB_calc",260,18,0,1,"STPR:BSYH:854:OUTB_calc") #! Field("STPR:BSYH:854:OUTB_calc.INPA",16777215,0,"STPR:BSYH:854:OUTB_calc.INPA") #! Link("STPR:BSYH:854:OUTB_calc.INPA","PLC:BSY0:PP06:D2_RDBb10.VAL") #! Field("STPR:BSYH:854:OUTB_calc.INPB",16777215,1,"STPR:BSYH:854:OUTB_calc.INPB") #! Field("STPR:BSYH:854:OUTB_calc.OUT",16777215,1,"STPR:BSYH:854:OUTB_calc.OUT") #! Link("STPR:BSYH:854:OUTB_calc.OUT","STPR:BSYH:854:OUTB.VAL") #! Record("STPR:BSYH:854:OUTB",500,20,0,0,"STPR:BSYH:854:OUTB") #! Field("STPR:BSYH:854:OUTB.VAL",16777215,1,"STPR:BSYH:854:OUTB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi9") { field(DESC, "Port D2_RDB bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 9, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:905:INB_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:INB_calc") { field(INPA, "PLC:BSY0:PP06:Bi9 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:INB PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:INB") { field(DESC, "ST61_IN_Limit_Switch_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb9",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb9") #! Field("PLC:BSY0:PP06:D2_RDBb9.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb9.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb9.FLNK","STPR:BSYH:905:INB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb9.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb9.VAL") #! Record("STPR:BSYH:905:INB_calc",260,18,0,1,"STPR:BSYH:905:INB_calc") #! Field("STPR:BSYH:905:INB_calc.INPA",16777215,0,"STPR:BSYH:905:INB_calc.INPA") #! Link("STPR:BSYH:905:INB_calc.INPA","PLC:BSY0:PP06:D2_RDBb9.VAL") #! Field("STPR:BSYH:905:INB_calc.INPB",16777215,1,"STPR:BSYH:905:INB_calc.INPB") #! Field("STPR:BSYH:905:INB_calc.OUT",16777215,1,"STPR:BSYH:905:INB_calc.OUT") #! Link("STPR:BSYH:905:INB_calc.OUT","STPR:BSYH:905:INB.VAL") #! Record("STPR:BSYH:905:INB",500,20,0,0,"STPR:BSYH:905:INB") #! Field("STPR:BSYH:905:INB.VAL",16777215,1,"STPR:BSYH:905:INB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi8") { field(DESC, "Port D2_RDB bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 8, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:905:OUTB_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:OUTB_calc") { field(INPA, "PLC:BSY0:PP06:Bi8 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:OUTB PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:OUTB") { field(DESC, "ST61_OUT_Limit_Switch_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb8",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb8") #! Field("PLC:BSY0:PP06:D2_RDBb8.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb8.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb8.FLNK","STPR:BSYH:905:OUTB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb8.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb8.VAL") #! Record("STPR:BSYH:905:OUTB_calc",260,18,0,1,"STPR:BSYH:905:OUTB_calc") #! Field("STPR:BSYH:905:OUTB_calc.INPA",16777215,0,"STPR:BSYH:905:OUTB_calc.INPA") #! Link("STPR:BSYH:905:OUTB_calc.INPA","PLC:BSY0:PP06:D2_RDBb8.VAL") #! Field("STPR:BSYH:905:OUTB_calc.INPB",16777215,1,"STPR:BSYH:905:OUTB_calc.INPB") #! Field("STPR:BSYH:905:OUTB_calc.OUT",16777215,1,"STPR:BSYH:905:OUTB_calc.OUT") #! Link("STPR:BSYH:905:OUTB_calc.OUT","STPR:BSYH:905:OUTB.VAL") #! Record("STPR:BSYH:905:OUTB",500,20,0,0,"STPR:BSYH:905:OUTB") #! Field("STPR:BSYH:905:OUTB.VAL",16777215,1,"STPR:BSYH:905:OUTB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi23") { field(DESC, "Port D2_RDB bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 23, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "BTM:BSYH:858:INB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:INB_calc") { field(INPA, "PLC:BSY0:PP06:Bi23 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:INB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:INB") { field(DESC, "DM60_IN_Limit_Switch_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb23",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb23") #! Field("PLC:BSY0:PP06:D2_RDBb23.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb23.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb23.FLNK","BTM:BSYH:858:INB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb23.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb23.VAL") #! Record("BTM:BSYH:858:INB_calc",260,18,0,1,"BTM:BSYH:858:INB_calc") #! Field("BTM:BSYH:858:INB_calc.INPA",16777215,0,"BTM:BSYH:858:INB_calc.INPA") #! Link("BTM:BSYH:858:INB_calc.INPA","PLC:BSY0:PP06:D2_RDBb23.VAL") #! Field("BTM:BSYH:858:INB_calc.INPB",16777215,1,"BTM:BSYH:858:INB_calc.INPB") #! Field("BTM:BSYH:858:INB_calc.OUT",16777215,1,"BTM:BSYH:858:INB_calc.OUT") #! Link("BTM:BSYH:858:INB_calc.OUT","BTM:BSYH:858:INB.VAL") #! Record("BTM:BSYH:858:INB",500,20,0,0,"BTM:BSYH:858:INB") #! Field("BTM:BSYH:858:INB.VAL",16777215,1,"BTM:BSYH:858:INB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi22") { field(DESC, "Port D2_RDB bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 22, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "BTM:BSYH:858:OUTB_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:OUTB_calc") { field(INPA, "PLC:BSY0:PP06:Bi22 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:OUTB PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:OUTB") { field(DESC, "DM60_OUT_Limit_Switch_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb22",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb22") #! Field("PLC:BSY0:PP06:D2_RDBb22.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb22.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb22.FLNK","BTM:BSYH:858:OUTB_calc") #! Field("PLC:BSY0:PP06:D2_RDBb22.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb22.VAL") #! Record("BTM:BSYH:858:OUTB_calc",260,18,0,1,"BTM:BSYH:858:OUTB_calc") #! Field("BTM:BSYH:858:OUTB_calc.INPA",16777215,0,"BTM:BSYH:858:OUTB_calc.INPA") #! Link("BTM:BSYH:858:OUTB_calc.INPA","PLC:BSY0:PP06:D2_RDBb22.VAL") #! Field("BTM:BSYH:858:OUTB_calc.INPB",16777215,1,"BTM:BSYH:858:OUTB_calc.INPB") #! Field("BTM:BSYH:858:OUTB_calc.OUT",16777215,1,"BTM:BSYH:858:OUTB_calc.OUT") #! Link("BTM:BSYH:858:OUTB_calc.OUT","BTM:BSYH:858:OUTB.VAL") #! Record("BTM:BSYH:858:OUTB",500,20,0,0,"BTM:BSYH:858:OUTB") #! Field("BTM:BSYH:858:OUTB.VAL",16777215,1,"BTM:BSYH:858:OUTB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi21") { field(DESC, "Port D2_RDB bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 21, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:1:STD2_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:STD2_IN_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi21 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:STD2_IN_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:STD2_IN_B") { field(DESC, "STD2_SR_FDBK_In_Sum_Inp_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb21",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb21") #! Field("PLC:BSY0:PP06:D2_RDBb21.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb21.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb21.FLNK","STPR:BSYH:1:STD2_IN_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb21.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb21.VAL") #! Record("STPR:BSYH:1:STD2_IN_B_calc",260,18,0,1,"STPR:BSYH:1:STD2_IN_B_calc") #! Field("STPR:BSYH:1:STD2_IN_B_calc.INPA",16777215,0,"STPR:BSYH:1:STD2_IN_B_calc.INPA") #! Link("STPR:BSYH:1:STD2_IN_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb21.VAL") #! Field("STPR:BSYH:1:STD2_IN_B_calc.INPB",16777215,1,"STPR:BSYH:1:STD2_IN_B_calc.INPB") #! Field("STPR:BSYH:1:STD2_IN_B_calc.OUT",16777215,1,"STPR:BSYH:1:STD2_IN_B_calc.OUT") #! Link("STPR:BSYH:1:STD2_IN_B_calc.OUT","STPR:BSYH:1:STD2_IN_B.VAL") #! Record("STPR:BSYH:1:STD2_IN_B",500,20,0,0,"STPR:BSYH:1:STD2_IN_B") #! Field("STPR:BSYH:1:STD2_IN_B.VAL",16777215,1,"STPR:BSYH:1:STD2_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi20") { field(DESC, "Port D2_RDB bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 20, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:1:STD2_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:STD2_OUT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi20 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:STD2_OUT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:STD2_OUT_B") { field(DESC, "STD2_SR_FDBK_Out_Sum_Inp_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb20",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb20") #! Field("PLC:BSY0:PP06:D2_RDBb20.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb20.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb20.FLNK","STPR:BSYH:1:STD2_OUT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb20.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb20.VAL") #! Record("STPR:BSYH:1:STD2_OUT_B_calc",260,18,0,1,"STPR:BSYH:1:STD2_OUT_B_calc") #! Field("STPR:BSYH:1:STD2_OUT_B_calc.INPA",16777215,0,"STPR:BSYH:1:STD2_OUT_B_calc.INPA") #! Link("STPR:BSYH:1:STD2_OUT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb20.VAL") #! Field("STPR:BSYH:1:STD2_OUT_B_calc.INPB",16777215,1,"STPR:BSYH:1:STD2_OUT_B_calc.INPB") #! Field("STPR:BSYH:1:STD2_OUT_B_calc.OUT",16777215,1,"STPR:BSYH:1:STD2_OUT_B_calc.OUT") #! Link("STPR:BSYH:1:STD2_OUT_B_calc.OUT","STPR:BSYH:1:STD2_OUT_B.VAL") #! Record("STPR:BSYH:1:STD2_OUT_B",500,20,0,0,"STPR:BSYH:1:STD2_OUT_B") #! Field("STPR:BSYH:1:STD2_OUT_B.VAL",16777215,1,"STPR:BSYH:1:STD2_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi19") { field(DESC, "Port D2_RDB bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 19, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:BSYH:1:STD2_ADMIN_EN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2_ADMIN_EN_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi19 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2_ADMIN_EN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2_ADMIN_EN_B") { field(DESC, "STD2_Admin_Enable_Keysw_B") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb19",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb19") #! Field("PLC:BSY0:PP06:D2_RDBb19.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb19.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb19.FLNK","PPS:BSYH:1:STD2_ADMIN_EN_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb19.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb19.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_B_calc",260,18,0,1,"PPS:BSYH:1:STD2_ADMIN_EN_B_calc") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2_ADMIN_EN_B_calc.INPA") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb19.VAL") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_B_calc.INPB") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_B_calc.OUT") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_B_calc.OUT","PPS:BSYH:1:STD2_ADMIN_EN_B.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_B",500,20,0,0,"PPS:BSYH:1:STD2_ADMIN_EN_B") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_B.VAL",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi18") { field(DESC, "Port D2_RDB bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 18, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYH:847:MOTOR_PWR_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_PWR_OK_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi18 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_PWR_OK_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_PWR_OK_B") { field(DESC, "STD2_Motor_Power_OK_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb18",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb18") #! Field("PLC:BSY0:PP06:D2_RDBb18.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb18.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb18.FLNK","STPR:BSYH:847:MOTOR_PWR_OK_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb18.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb18.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_B_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_PWR_OK_B_calc") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_B_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_PWR_OK_B_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb18.VAL") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_B_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_B_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_B_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_B_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_B_calc.OUT","STPR:BSYH:847:MOTOR_PWR_OK_B.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_B",500,20,0,0,"STPR:BSYH:847:MOTOR_PWR_OK_B") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_B.VAL",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi17") { field(DESC, "Port D2_RDB bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 17, 1, 1)") field(ZNAM, "Test") field(ONAM, "Normal") field(FLNK, "PPS:BSYH:1:BTH_TEST_MODE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:BTH_TEST_MODE_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi17 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:BTH_TEST_MODE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:BTH_TEST_MODE_B") { field(DESC, "BTH_In_Test_Mode_B") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb17",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb17") #! Field("PLC:BSY0:PP06:D2_RDBb17.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb17.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb17.FLNK","PPS:BSYH:1:BTH_TEST_MODE_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb17.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb17.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_B_calc",260,18,0,1,"PPS:BSYH:1:BTH_TEST_MODE_B_calc") #! Field("PPS:BSYH:1:BTH_TEST_MODE_B_calc.INPA",16777215,0,"PPS:BSYH:1:BTH_TEST_MODE_B_calc.INPA") #! Link("PPS:BSYH:1:BTH_TEST_MODE_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb17.VAL") #! Field("PPS:BSYH:1:BTH_TEST_MODE_B_calc.INPB",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_B_calc.INPB") #! Field("PPS:BSYH:1:BTH_TEST_MODE_B_calc.OUT",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_B_calc.OUT") #! Link("PPS:BSYH:1:BTH_TEST_MODE_B_calc.OUT","PPS:BSYH:1:BTH_TEST_MODE_B.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_B",500,20,0,0,"PPS:BSYH:1:BTH_TEST_MODE_B") #! Field("PPS:BSYH:1:BTH_TEST_MODE_B.VAL",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi91") { field(DESC, "Port D2_RDB bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HWALRMWARN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HWALRMWARN_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi91 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HWALRMWARN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HWALRMWARN_B") { field(DESC, "HW_Alarm_Warning_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb91",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb91") #! Field("PLC:BSY0:PP06:D2_RDBb91.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb91.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb91.FLNK","PPS:BSYH:1:STD2:HWALRMWARN_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb91.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb91.VAL") #! Record("PPS:BSYH:1:STD2:HWALRMWARN_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:HWALRMWARN_B_calc") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HWALRMWARN_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:HWALRMWARN_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb91.VAL") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HWALRMWARN_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HWALRMWARN_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:HWALRMWARN_B_calc.OUT","PPS:BSYH:1:STD2:HWALRMWARN_B.VAL") #! Record("PPS:BSYH:1:STD2:HWALRMWARN_B",500,20,0,0,"PPS:BSYH:1:STD2:HWALRMWARN_B") #! Field("PPS:BSYH:1:STD2:HWALRMWARN_B.VAL",16777215,1,"PPS:BSYH:1:STD2:HWALRMWARN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi90") { field(DESC, "Port D2_RDB bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi90 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_OUTP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_OUTP_B") { field(DESC, "PLC_Heartbeat_Output_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb90",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb90") #! Field("PLC:BSY0:PP06:D2_RDBb90.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb90.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb90.FLNK","PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb90.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb90.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb90.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_OUTP_B_calc.OUT","PPS:BSYH:1:STD2:HRTBT_OUTP_B.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OUTP_B",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_OUTP_B") #! Field("PPS:BSYH:1:STD2:HRTBT_OUTP_B.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OUTP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi89") { field(DESC, "Port D2_RDB bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 89, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:BSYH:2:STD2_IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_IN_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi89 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_IN_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_IN_B") { field(DESC, "STD2_In_Sum_Output_To_SR_B") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb89",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb89") #! Field("PLC:BSY0:PP06:D2_RDBb89.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb89.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb89.FLNK","STPR:BSYH:2:STD2_IN_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb89.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb89.VAL") #! Record("STPR:BSYH:2:STD2_IN_B_calc",260,18,0,1,"STPR:BSYH:2:STD2_IN_B_calc") #! Field("STPR:BSYH:2:STD2_IN_B_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_IN_B_calc.INPA") #! Link("STPR:BSYH:2:STD2_IN_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb89.VAL") #! Field("STPR:BSYH:2:STD2_IN_B_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_IN_B_calc.INPB") #! Field("STPR:BSYH:2:STD2_IN_B_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_IN_B_calc.OUT") #! Link("STPR:BSYH:2:STD2_IN_B_calc.OUT","STPR:BSYH:2:STD2_IN_B.VAL") #! Record("STPR:BSYH:2:STD2_IN_B",500,20,0,0,"STPR:BSYH:2:STD2_IN_B") #! Field("STPR:BSYH:2:STD2_IN_B.VAL",16777215,1,"STPR:BSYH:2:STD2_IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi88") { field(DESC, "Port D2_RDB bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 88, 1, 1)") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(FLNK, "STPR:BSYH:2:STD2_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_OUT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi88 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_OUT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_OUT_B") { field(DESC, "STD2_Out_Sum_Output_To_SR_B") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb88",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb88") #! Field("PLC:BSY0:PP06:D2_RDBb88.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb88.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb88.FLNK","STPR:BSYH:2:STD2_OUT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb88.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb88.VAL") #! Record("STPR:BSYH:2:STD2_OUT_B_calc",260,18,0,1,"STPR:BSYH:2:STD2_OUT_B_calc") #! Field("STPR:BSYH:2:STD2_OUT_B_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_OUT_B_calc.INPA") #! Link("STPR:BSYH:2:STD2_OUT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb88.VAL") #! Field("STPR:BSYH:2:STD2_OUT_B_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_OUT_B_calc.INPB") #! Field("STPR:BSYH:2:STD2_OUT_B_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_OUT_B_calc.OUT") #! Link("STPR:BSYH:2:STD2_OUT_B_calc.OUT","STPR:BSYH:2:STD2_OUT_B.VAL") #! Record("STPR:BSYH:2:STD2_OUT_B",500,20,0,0,"STPR:BSYH:2:STD2_OUT_B") #! Field("STPR:BSYH:2:STD2_OUT_B.VAL",16777215,1,"STPR:BSYH:2:STD2_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi103") { field(DESC, "Port D2_RDB bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:XINTLK_SELF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:XINTLK_SELF_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi103 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:XINTLK_SELF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:XINTLK_SELF_B") { field(DESC, "Self_Cross_Intlk_Output_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb103",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb103") #! Field("PLC:BSY0:PP06:D2_RDBb103.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb103.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb103.FLNK","PPS:BSYH:1:STD2:XINTLK_SELF_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb103.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb103.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_SELF_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:XINTLK_SELF_B_calc") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb103.VAL") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:XINTLK_SELF_B_calc.OUT","PPS:BSYH:1:STD2:XINTLK_SELF_B.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_SELF_B",500,20,0,0,"PPS:BSYH:1:STD2:XINTLK_SELF_B") #! Field("PPS:BSYH:1:STD2:XINTLK_SELF_B.VAL",16777215,1,"PPS:BSYH:1:STD2:XINTLK_SELF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi102") { field(DESC, "Port D2_RDB bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:XINTLK_OPP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:XINTLK_OPP_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi102 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:XINTLK_OPP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:XINTLK_OPP_B") { field(DESC, "Opposite_Cross_Intlk_Output_B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb102",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb102") #! Field("PLC:BSY0:PP06:D2_RDBb102.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb102.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb102.FLNK","PPS:BSYH:1:STD2:XINTLK_OPP_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb102.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb102.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_OPP_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:XINTLK_OPP_B_calc") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb102.VAL") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:XINTLK_OPP_B_calc.OUT","PPS:BSYH:1:STD2:XINTLK_OPP_B.VAL") #! Record("PPS:BSYH:1:STD2:XINTLK_OPP_B",500,20,0,0,"PPS:BSYH:1:STD2:XINTLK_OPP_B") #! Field("PPS:BSYH:1:STD2:XINTLK_OPP_B.VAL",16777215,1,"PPS:BSYH:1:STD2:XINTLK_OPP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi101") { field(DESC, "Port D2_RDB bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 101, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:BSYH:1:STD2:PERMITTED_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:PERMITTED_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi101 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:PERMITTED_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:PERMITTED_B") { field(DESC, "STD2_Permitted_B") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb101",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb101") #! Field("PLC:BSY0:PP06:D2_RDBb101.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb101.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb101.FLNK","PPS:BSYH:1:STD2:PERMITTED_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb101.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb101.VAL") #! Record("PPS:BSYH:1:STD2:PERMITTED_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:PERMITTED_B_calc") #! Field("PPS:BSYH:1:STD2:PERMITTED_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:PERMITTED_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:PERMITTED_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb101.VAL") #! Field("PPS:BSYH:1:STD2:PERMITTED_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:PERMITTED_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:PERMITTED_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:PERMITTED_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:PERMITTED_B_calc.OUT","PPS:BSYH:1:STD2:PERMITTED_B.VAL") #! Record("PPS:BSYH:1:STD2:PERMITTED_B",500,20,0,0,"PPS:BSYH:1:STD2:PERMITTED_B") #! Field("PPS:BSYH:1:STD2:PERMITTED_B.VAL",16777215,1,"PPS:BSYH:1:STD2:PERMITTED_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi100") { field(DESC, "Port D2_RDB bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:BCS_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:BCS_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi100 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:BCS_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:BCS_FAULT_B") { field(DESC, "BCS_Fault_from_PLC4B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb100",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb100") #! Field("PLC:BSY0:PP06:D2_RDBb100.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb100.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb100.FLNK","PPS:BSYH:1:STD2:BCS_FAULT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb100.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb100.VAL") #! Record("PPS:BSYH:1:STD2:BCS_FAULT_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:BCS_FAULT_B_calc") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:BCS_FAULT_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:BCS_FAULT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb100.VAL") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:BCS_FAULT_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:BCS_FAULT_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:BCS_FAULT_B_calc.OUT","PPS:BSYH:1:STD2:BCS_FAULT_B.VAL") #! Record("PPS:BSYH:1:STD2:BCS_FAULT_B",500,20,0,0,"PPS:BSYH:1:STD2:BCS_FAULT_B") #! Field("PPS:BSYH:1:STD2:BCS_FAULT_B.VAL",16777215,1,"PPS:BSYH:1:STD2:BCS_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi97") { field(DESC, "Port D2_RDB bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 97, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:847:MOTOR_DRV1_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_DRV1_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi97 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_DRV1_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_DRV1_B") { field(DESC, "STD2_Motor_Driver_Control_1_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb97",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb97") #! Field("PLC:BSY0:PP06:D2_RDBb97.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb97.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb97.FLNK","STPR:BSYH:847:MOTOR_DRV1_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb97.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb97.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV1_B_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_DRV1_B_calc") #! Field("STPR:BSYH:847:MOTOR_DRV1_B_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_DRV1_B_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_DRV1_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb97.VAL") #! Field("STPR:BSYH:847:MOTOR_DRV1_B_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_DRV1_B_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_DRV1_B_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_DRV1_B_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_DRV1_B_calc.OUT","STPR:BSYH:847:MOTOR_DRV1_B.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV1_B",500,20,0,0,"STPR:BSYH:847:MOTOR_DRV1_B") #! Field("STPR:BSYH:847:MOTOR_DRV1_B.VAL",16777215,1,"STPR:BSYH:847:MOTOR_DRV1_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi96") { field(DESC, "Port D2_RDB bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 96, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:847:MOTOR_DRV2_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_DRV2_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi96 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_DRV2_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_DRV2_B") { field(DESC, "STD2_Motor_Driver_Control_2_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb96",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb96") #! Field("PLC:BSY0:PP06:D2_RDBb96.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb96.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb96.FLNK","STPR:BSYH:847:MOTOR_DRV2_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb96.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb96.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV2_B_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_DRV2_B_calc") #! Field("STPR:BSYH:847:MOTOR_DRV2_B_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_DRV2_B_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_DRV2_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb96.VAL") #! Field("STPR:BSYH:847:MOTOR_DRV2_B_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_DRV2_B_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_DRV2_B_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_DRV2_B_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_DRV2_B_calc.OUT","STPR:BSYH:847:MOTOR_DRV2_B.VAL") #! Record("STPR:BSYH:847:MOTOR_DRV2_B",500,20,0,0,"STPR:BSYH:847:MOTOR_DRV2_B") #! Field("STPR:BSYH:847:MOTOR_DRV2_B.VAL",16777215,1,"STPR:BSYH:847:MOTOR_DRV2_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi111") { field(DESC, "Port D2_RDB bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 111, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:854:SOLENOID_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:SOLENOID_OUT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi111 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:SOLENOID_OUT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:SOLENOID_OUT_B") { field(DESC, "ST60_Solenoid_Air_Out_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb111",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb111") #! Field("PLC:BSY0:PP06:D2_RDBb111.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb111.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb111.FLNK","STPR:BSYH:854:SOLENOID_OUT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb111.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb111.VAL") #! Record("STPR:BSYH:854:SOLENOID_OUT_B_calc",260,18,0,1,"STPR:BSYH:854:SOLENOID_OUT_B_calc") #! Field("STPR:BSYH:854:SOLENOID_OUT_B_calc.INPA",16777215,0,"STPR:BSYH:854:SOLENOID_OUT_B_calc.INPA") #! Link("STPR:BSYH:854:SOLENOID_OUT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb111.VAL") #! Field("STPR:BSYH:854:SOLENOID_OUT_B_calc.INPB",16777215,1,"STPR:BSYH:854:SOLENOID_OUT_B_calc.INPB") #! Field("STPR:BSYH:854:SOLENOID_OUT_B_calc.OUT",16777215,1,"STPR:BSYH:854:SOLENOID_OUT_B_calc.OUT") #! Link("STPR:BSYH:854:SOLENOID_OUT_B_calc.OUT","STPR:BSYH:854:SOLENOID_OUT_B.VAL") #! Record("STPR:BSYH:854:SOLENOID_OUT_B",500,20,0,0,"STPR:BSYH:854:SOLENOID_OUT_B") #! Field("STPR:BSYH:854:SOLENOID_OUT_B.VAL",16777215,1,"STPR:BSYH:854:SOLENOID_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi110") { field(DESC, "Port D2_RDB bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 110, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:854:SOLENOID_RET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:SOLENOID_RET_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi110 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:SOLENOID_RET_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:SOLENOID_RET_B") { field(DESC, "ST60_Solenoid_Air_Return_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb110",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb110") #! Field("PLC:BSY0:PP06:D2_RDBb110.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb110.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb110.FLNK","STPR:BSYH:854:SOLENOID_RET_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb110.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb110.VAL") #! Record("STPR:BSYH:854:SOLENOID_RET_B_calc",260,18,0,1,"STPR:BSYH:854:SOLENOID_RET_B_calc") #! Field("STPR:BSYH:854:SOLENOID_RET_B_calc.INPA",16777215,0,"STPR:BSYH:854:SOLENOID_RET_B_calc.INPA") #! Link("STPR:BSYH:854:SOLENOID_RET_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb110.VAL") #! Field("STPR:BSYH:854:SOLENOID_RET_B_calc.INPB",16777215,1,"STPR:BSYH:854:SOLENOID_RET_B_calc.INPB") #! Field("STPR:BSYH:854:SOLENOID_RET_B_calc.OUT",16777215,1,"STPR:BSYH:854:SOLENOID_RET_B_calc.OUT") #! Link("STPR:BSYH:854:SOLENOID_RET_B_calc.OUT","STPR:BSYH:854:SOLENOID_RET_B.VAL") #! Record("STPR:BSYH:854:SOLENOID_RET_B",500,20,0,0,"STPR:BSYH:854:SOLENOID_RET_B") #! Field("STPR:BSYH:854:SOLENOID_RET_B.VAL",16777215,1,"STPR:BSYH:854:SOLENOID_RET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi109") { field(DESC, "Port D2_RDB bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 109, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:905:SOLENOID_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:SOLENOID_OUT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi109 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:SOLENOID_OUT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:SOLENOID_OUT_B") { field(DESC, "ST61_Solenoid_Air_Out_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb109",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb109") #! Field("PLC:BSY0:PP06:D2_RDBb109.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb109.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb109.FLNK","STPR:BSYH:905:SOLENOID_OUT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb109.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb109.VAL") #! Record("STPR:BSYH:905:SOLENOID_OUT_B_calc",260,18,0,1,"STPR:BSYH:905:SOLENOID_OUT_B_calc") #! Field("STPR:BSYH:905:SOLENOID_OUT_B_calc.INPA",16777215,0,"STPR:BSYH:905:SOLENOID_OUT_B_calc.INPA") #! Link("STPR:BSYH:905:SOLENOID_OUT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb109.VAL") #! Field("STPR:BSYH:905:SOLENOID_OUT_B_calc.INPB",16777215,1,"STPR:BSYH:905:SOLENOID_OUT_B_calc.INPB") #! Field("STPR:BSYH:905:SOLENOID_OUT_B_calc.OUT",16777215,1,"STPR:BSYH:905:SOLENOID_OUT_B_calc.OUT") #! Link("STPR:BSYH:905:SOLENOID_OUT_B_calc.OUT","STPR:BSYH:905:SOLENOID_OUT_B.VAL") #! Record("STPR:BSYH:905:SOLENOID_OUT_B",500,20,0,0,"STPR:BSYH:905:SOLENOID_OUT_B") #! Field("STPR:BSYH:905:SOLENOID_OUT_B.VAL",16777215,1,"STPR:BSYH:905:SOLENOID_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi108") { field(DESC, "Port D2_RDB bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 108, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "STPR:BSYH:905:SOLENOID_RET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:SOLENOID_RET_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi108 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:SOLENOID_RET_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:SOLENOID_RET_B") { field(DESC, "ST61_Solenoid_Air_Return_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb108",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb108") #! Field("PLC:BSY0:PP06:D2_RDBb108.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb108.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb108.FLNK","STPR:BSYH:905:SOLENOID_RET_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb108.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb108.VAL") #! Record("STPR:BSYH:905:SOLENOID_RET_B_calc",260,18,0,1,"STPR:BSYH:905:SOLENOID_RET_B_calc") #! Field("STPR:BSYH:905:SOLENOID_RET_B_calc.INPA",16777215,0,"STPR:BSYH:905:SOLENOID_RET_B_calc.INPA") #! Link("STPR:BSYH:905:SOLENOID_RET_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb108.VAL") #! Field("STPR:BSYH:905:SOLENOID_RET_B_calc.INPB",16777215,1,"STPR:BSYH:905:SOLENOID_RET_B_calc.INPB") #! Field("STPR:BSYH:905:SOLENOID_RET_B_calc.OUT",16777215,1,"STPR:BSYH:905:SOLENOID_RET_B_calc.OUT") #! Link("STPR:BSYH:905:SOLENOID_RET_B_calc.OUT","STPR:BSYH:905:SOLENOID_RET_B.VAL") #! Record("STPR:BSYH:905:SOLENOID_RET_B",500,20,0,0,"STPR:BSYH:905:SOLENOID_RET_B") #! Field("STPR:BSYH:905:SOLENOID_RET_B.VAL",16777215,1,"STPR:BSYH:905:SOLENOID_RET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi107") { field(DESC, "Port D2_RDB bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 107, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "BTM:BSYH:858:SOLENOID_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:SOLENOID_OUT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi107 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:SOLENOID_OUT_B PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:SOLENOID_OUT_B") { field(DESC, "DM60_Solenoid_Air_Out_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb107",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb107") #! Field("PLC:BSY0:PP06:D2_RDBb107.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb107.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb107.FLNK","BTM:BSYH:858:SOLENOID_OUT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb107.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb107.VAL") #! Record("BTM:BSYH:858:SOLENOID_OUT_B_calc",260,18,0,1,"BTM:BSYH:858:SOLENOID_OUT_B_calc") #! Field("BTM:BSYH:858:SOLENOID_OUT_B_calc.INPA",16777215,0,"BTM:BSYH:858:SOLENOID_OUT_B_calc.INPA") #! Link("BTM:BSYH:858:SOLENOID_OUT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb107.VAL") #! Field("BTM:BSYH:858:SOLENOID_OUT_B_calc.INPB",16777215,1,"BTM:BSYH:858:SOLENOID_OUT_B_calc.INPB") #! Field("BTM:BSYH:858:SOLENOID_OUT_B_calc.OUT",16777215,1,"BTM:BSYH:858:SOLENOID_OUT_B_calc.OUT") #! Link("BTM:BSYH:858:SOLENOID_OUT_B_calc.OUT","BTM:BSYH:858:SOLENOID_OUT_B.VAL") #! Record("BTM:BSYH:858:SOLENOID_OUT_B",500,20,0,0,"BTM:BSYH:858:SOLENOID_OUT_B") #! Field("BTM:BSYH:858:SOLENOID_OUT_B.VAL",16777215,1,"BTM:BSYH:858:SOLENOID_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi106") { field(DESC, "Port D2_RDB bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 106, 1, 1)") field(ZNAM, "OFF") field(ONAM, "ON") field(FLNK, "BTM:BSYH:858:SOLENOID_RET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:SOLENOID_RET_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi106 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:SOLENOID_RET_B PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:SOLENOID_RET_B") { field(DESC, "DM60_Solenoid_Air_Return_B") field(ZNAM, "OFF") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb106",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb106") #! Field("PLC:BSY0:PP06:D2_RDBb106.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb106.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb106.FLNK","BTM:BSYH:858:SOLENOID_RET_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb106.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb106.VAL") #! Record("BTM:BSYH:858:SOLENOID_RET_B_calc",260,18,0,1,"BTM:BSYH:858:SOLENOID_RET_B_calc") #! Field("BTM:BSYH:858:SOLENOID_RET_B_calc.INPA",16777215,0,"BTM:BSYH:858:SOLENOID_RET_B_calc.INPA") #! Link("BTM:BSYH:858:SOLENOID_RET_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb106.VAL") #! Field("BTM:BSYH:858:SOLENOID_RET_B_calc.INPB",16777215,1,"BTM:BSYH:858:SOLENOID_RET_B_calc.INPB") #! Field("BTM:BSYH:858:SOLENOID_RET_B_calc.OUT",16777215,1,"BTM:BSYH:858:SOLENOID_RET_B_calc.OUT") #! Link("BTM:BSYH:858:SOLENOID_RET_B_calc.OUT","BTM:BSYH:858:SOLENOID_RET_B.VAL") #! Record("BTM:BSYH:858:SOLENOID_RET_B",500,20,0,0,"BTM:BSYH:858:SOLENOID_RET_B") #! Field("BTM:BSYH:858:SOLENOID_RET_B.VAL",16777215,1,"BTM:BSYH:858:SOLENOID_RET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi105") { field(DESC, "Port D2_RDB bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 105, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi105 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B") { field(DESC, "LCLS Secure Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb105",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb105") #! Field("PLC:BSY0:PP06:D2_RDBb105.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb105.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb105.FLNK","PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb105.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb105.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb105.VAL") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B_calc.OUT","PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B") #! Field("PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2:LCLS_SECURE_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi104") { field(DESC, "Port D2_RDB bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 104, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi104 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B") { field(DESC, "BSOICs Grp. C OK Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb104",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb104") #! Field("PLC:BSY0:PP06:D2_RDBb104.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb104.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb104.FLNK","PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb104.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb104.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb104.VAL") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B_calc.OUT","PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B") #! Field("PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2:BSOICS_C_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi119") { field(DESC, "Port D2_RDB bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 119, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi119 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:1:HXR:KICK_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:1:HXR:KICK_OFF_LTH_B") { field(DESC, "HXR_Kicker_Off_Sum_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb119",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb119") #! Field("PLC:BSY0:PP06:D2_RDBb119.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb119.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb119.FLNK","PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb119.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb119.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc",260,18,0,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.INPA",16777215,0,"PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.INPA") #! Link("PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb119.VAL") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.INPB",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.INPB") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.OUT",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.OUT") #! Link("PPS:LI28:1:HXR:KICK_OFF_LTH_B_calc.OUT","PPS:LI28:1:HXR:KICK_OFF_LTH_B.VAL") #! Record("PPS:LI28:1:HXR:KICK_OFF_LTH_B",500,20,0,0,"PPS:LI28:1:HXR:KICK_OFF_LTH_B") #! Field("PPS:LI28:1:HXR:KICK_OFF_LTH_B.VAL",16777215,1,"PPS:LI28:1:HXR:KICK_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi118") { field(DESC, "Port D2_RDB bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 118, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi118 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:GEN_INTLK_LTH_B") { field(DESC, "Generic_D2_Interlock_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb118",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb118") #! Field("PLC:BSY0:PP06:D2_RDBb118.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb118.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb118.FLNK","PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb118.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb118.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb118.VAL") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B_calc.OUT","PPS:BSYH:1:STD2:GEN_INTLK_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_B") #! Field("PPS:BSYH:1:STD2:GEN_INTLK_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2:GEN_INTLK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi117") { field(DESC, "Port D2_RDB bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 117, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi117 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_B") { field(DESC, "PLC4_Enable_Keysw_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb117",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb117") #! Field("PLC:BSY0:PP06:D2_RDBb117.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb117.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb117.FLNK","PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb117.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb117.VAL") #! Record("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb117.VAL") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B_calc.OUT","PPS:BSYH:1:STD2:STOP_ENBL_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_B") #! Field("PPS:BSYH:1:STD2:STOP_ENBL_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2:STOP_ENBL_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi116") { field(DESC, "Port D2_RDB bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi116 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_B") { field(DESC, "STD2_Admin_Enable_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb116",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb116") #! Field("PLC:BSY0:PP06:D2_RDBb116.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb116.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb116.FLNK","PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb116.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb116.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb116.VAL") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B_calc.OUT","PPS:BSYH:1:STD2_ADMIN_EN_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_B") #! Field("PPS:BSYH:1:STD2_ADMIN_EN_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2_ADMIN_EN_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi115") { field(DESC, "Port D2_RDB bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi115 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:847:MOTOR_PWR_OK_LTH_B") { field(DESC, "STD2_Motor_Power_OK_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb115",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb115") #! Field("PLC:BSY0:PP06:D2_RDBb115.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb115.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb115.FLNK","STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb115.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb115.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc",260,18,0,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.INPA",16777215,0,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.INPA") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb115.VAL") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.INPB",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.INPB") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.OUT",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.OUT") #! Link("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B_calc.OUT","STPR:BSYH:847:MOTOR_PWR_OK_LTH_B.VAL") #! Record("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B",500,20,0,0,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_B") #! Field("STPR:BSYH:847:MOTOR_PWR_OK_LTH_B.VAL",16777215,1,"STPR:BSYH:847:MOTOR_PWR_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi114") { field(DESC, "Port D2_RDB bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi114 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:BTH_TEST_MODE_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:BTH_TEST_MODE_LTH_B") { field(DESC, "BTH_In_Test_Mode_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb114",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb114") #! Field("PLC:BSY0:PP06:D2_RDBb114.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb114.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb114.FLNK","PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb114.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb114.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb114.VAL") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:BTH_TEST_MODE_LTH_B_calc.OUT","PPS:BSYH:1:BTH_TEST_MODE_LTH_B.VAL") #! Record("PPS:BSYH:1:BTH_TEST_MODE_LTH_B",500,20,0,0,"PPS:BSYH:1:BTH_TEST_MODE_LTH_B") #! Field("PPS:BSYH:1:BTH_TEST_MODE_LTH_B.VAL",16777215,1,"PPS:BSYH:1:BTH_TEST_MODE_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi113") { field(DESC, "Port D2_RDB bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi113 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_OK_LTH_B") { field(DESC, "Heartbeats_Ok_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb113",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb113") #! Field("PLC:BSY0:PP06:D2_RDBb113.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb113.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb113.FLNK","PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb113.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb113.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb113.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B_calc.OUT","PPS:BSYH:1:STD2:HRTBT_OK_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_B") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi127") { field(DESC, "Port D2_RDB bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 127, 1, 1)") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(FLNK, "PPS:BSYH:1:STD2:HRTBT_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:HRTBT_OK_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi127 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:HRTBT_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:HRTBT_OK_B") { field(DESC, "Heartbeat OK B") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb127",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb127") #! Field("PLC:BSY0:PP06:D2_RDBb127.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb127.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb127.FLNK","PPS:BSYH:1:STD2:HRTBT_OK_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb127.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb127.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:HRTBT_OK_B_calc") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:HRTBT_OK_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb127.VAL") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:HRTBT_OK_B_calc.OUT","PPS:BSYH:1:STD2:HRTBT_OK_B.VAL") #! Record("PPS:BSYH:1:STD2:HRTBT_OK_B",500,20,0,0,"PPS:BSYH:1:STD2:HRTBT_OK_B") #! Field("PPS:BSYH:1:STD2:HRTBT_OK_B.VAL",16777215,1,"PPS:BSYH:1:STD2:HRTBT_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi123") { field(DESC, "Port D2_RDB bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 123, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:2:STD2_IN_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_IN_LAT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi123 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_IN_LAT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_IN_LAT_B") { field(DESC, "STD2_In_Sum_Out_To_SR_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb123",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb123") #! Field("PLC:BSY0:PP06:D2_RDBb123.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb123.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb123.FLNK","STPR:BSYH:2:STD2_IN_LAT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb123.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb123.VAL") #! Record("STPR:BSYH:2:STD2_IN_LAT_B_calc",260,18,0,1,"STPR:BSYH:2:STD2_IN_LAT_B_calc") #! Field("STPR:BSYH:2:STD2_IN_LAT_B_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_IN_LAT_B_calc.INPA") #! Link("STPR:BSYH:2:STD2_IN_LAT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb123.VAL") #! Field("STPR:BSYH:2:STD2_IN_LAT_B_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_IN_LAT_B_calc.INPB") #! Field("STPR:BSYH:2:STD2_IN_LAT_B_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_IN_LAT_B_calc.OUT") #! Link("STPR:BSYH:2:STD2_IN_LAT_B_calc.OUT","STPR:BSYH:2:STD2_IN_LAT_B.VAL") #! Record("STPR:BSYH:2:STD2_IN_LAT_B",500,20,0,0,"STPR:BSYH:2:STD2_IN_LAT_B") #! Field("STPR:BSYH:2:STD2_IN_LAT_B.VAL",16777215,1,"STPR:BSYH:2:STD2_IN_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi122") { field(DESC, "Port D2_RDB bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 122, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:2:STD2_OUT_LAT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:2:STD2_OUT_LAT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi122 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:2:STD2_OUT_LAT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:2:STD2_OUT_LAT_B") { field(DESC, "STD2_Out_Sum_Out_To_SR_Lat_B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb122",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb122") #! Field("PLC:BSY0:PP06:D2_RDBb122.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb122.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb122.FLNK","STPR:BSYH:2:STD2_OUT_LAT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb122.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb122.VAL") #! Record("STPR:BSYH:2:STD2_OUT_LAT_B_calc",260,18,0,1,"STPR:BSYH:2:STD2_OUT_LAT_B_calc") #! Field("STPR:BSYH:2:STD2_OUT_LAT_B_calc.INPA",16777215,0,"STPR:BSYH:2:STD2_OUT_LAT_B_calc.INPA") #! Link("STPR:BSYH:2:STD2_OUT_LAT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb122.VAL") #! Field("STPR:BSYH:2:STD2_OUT_LAT_B_calc.INPB",16777215,1,"STPR:BSYH:2:STD2_OUT_LAT_B_calc.INPB") #! Field("STPR:BSYH:2:STD2_OUT_LAT_B_calc.OUT",16777215,1,"STPR:BSYH:2:STD2_OUT_LAT_B_calc.OUT") #! Link("STPR:BSYH:2:STD2_OUT_LAT_B_calc.OUT","STPR:BSYH:2:STD2_OUT_LAT_B.VAL") #! Record("STPR:BSYH:2:STD2_OUT_LAT_B",500,20,0,0,"STPR:BSYH:2:STD2_OUT_LAT_B") #! Field("STPR:BSYH:2:STD2_OUT_LAT_B.VAL",16777215,1,"STPR:BSYH:2:STD2_OUT_LAT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi121") { field(DESC, "Port D2_RDB bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 121, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "PPS:BSYH:1:STD2:STOP_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOP_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi121 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOP_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOP_FAULT_B") { field(DESC, "D2 Stopper Fault B") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb121",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb121") #! Field("PLC:BSY0:PP06:D2_RDBb121.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb121.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb121.FLNK","PPS:BSYH:1:STD2:STOP_FAULT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb121.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb121.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOP_FAULT_B_calc") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOP_FAULT_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb121.VAL") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_B_calc.OUT","PPS:BSYH:1:STD2:STOP_FAULT_B.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_B",500,20,0,0,"PPS:BSYH:1:STD2:STOP_FAULT_B") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_B.VAL",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi120") { field(DESC, "Port D2_RDB bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 120, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "STPR:BSYH:854:STOP_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:STOP_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi120 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:STOP_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:STOP_FAULT_B") { field(DESC, "ST60 Stopper Fault B") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb120",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb120") #! Field("PLC:BSY0:PP06:D2_RDBb120.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb120.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb120.FLNK","STPR:BSYH:854:STOP_FAULT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb120.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb120.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_B_calc",260,18,0,1,"STPR:BSYH:854:STOP_FAULT_B_calc") #! Field("STPR:BSYH:854:STOP_FAULT_B_calc.INPA",16777215,0,"STPR:BSYH:854:STOP_FAULT_B_calc.INPA") #! Link("STPR:BSYH:854:STOP_FAULT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb120.VAL") #! Field("STPR:BSYH:854:STOP_FAULT_B_calc.INPB",16777215,1,"STPR:BSYH:854:STOP_FAULT_B_calc.INPB") #! Field("STPR:BSYH:854:STOP_FAULT_B_calc.OUT",16777215,1,"STPR:BSYH:854:STOP_FAULT_B_calc.OUT") #! Link("STPR:BSYH:854:STOP_FAULT_B_calc.OUT","STPR:BSYH:854:STOP_FAULT_B.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_B",500,20,0,0,"STPR:BSYH:854:STOP_FAULT_B") #! Field("STPR:BSYH:854:STOP_FAULT_B.VAL",16777215,1,"STPR:BSYH:854:STOP_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi135") { field(DESC, "Port D2_RDB bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 135, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "STPR:BSYH:905:STOP_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:STOP_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi135 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:STOP_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:STOP_FAULT_B") { field(DESC, "ST61 Stopper Fault B") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb135",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb135") #! Field("PLC:BSY0:PP06:D2_RDBb135.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb135.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb135.FLNK","STPR:BSYH:905:STOP_FAULT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb135.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb135.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_B_calc",260,18,0,1,"STPR:BSYH:905:STOP_FAULT_B_calc") #! Field("STPR:BSYH:905:STOP_FAULT_B_calc.INPA",16777215,0,"STPR:BSYH:905:STOP_FAULT_B_calc.INPA") #! Link("STPR:BSYH:905:STOP_FAULT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb135.VAL") #! Field("STPR:BSYH:905:STOP_FAULT_B_calc.INPB",16777215,1,"STPR:BSYH:905:STOP_FAULT_B_calc.INPB") #! Field("STPR:BSYH:905:STOP_FAULT_B_calc.OUT",16777215,1,"STPR:BSYH:905:STOP_FAULT_B_calc.OUT") #! Link("STPR:BSYH:905:STOP_FAULT_B_calc.OUT","STPR:BSYH:905:STOP_FAULT_B.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_B",500,20,0,0,"STPR:BSYH:905:STOP_FAULT_B") #! Field("STPR:BSYH:905:STOP_FAULT_B.VAL",16777215,1,"STPR:BSYH:905:STOP_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi134") { field(DESC, "Port D2_RDB bit 134") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 134, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BTM:BSYH:858:STOP_FAULT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:STOP_FAULT_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi134 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:STOP_FAULT_B PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:STOP_FAULT_B") { field(DESC, "DM60 Stopper Fault B") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb134",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb134") #! Field("PLC:BSY0:PP06:D2_RDBb134.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb134.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb134.FLNK","BTM:BSYH:858:STOP_FAULT_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb134.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb134.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_B_calc",260,18,0,1,"BTM:BSYH:858:STOP_FAULT_B_calc") #! Field("BTM:BSYH:858:STOP_FAULT_B_calc.INPA",16777215,0,"BTM:BSYH:858:STOP_FAULT_B_calc.INPA") #! Link("BTM:BSYH:858:STOP_FAULT_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb134.VAL") #! Field("BTM:BSYH:858:STOP_FAULT_B_calc.INPB",16777215,1,"BTM:BSYH:858:STOP_FAULT_B_calc.INPB") #! Field("BTM:BSYH:858:STOP_FAULT_B_calc.OUT",16777215,1,"BTM:BSYH:858:STOP_FAULT_B_calc.OUT") #! Link("BTM:BSYH:858:STOP_FAULT_B_calc.OUT","BTM:BSYH:858:STOP_FAULT_B.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_B",500,20,0,0,"BTM:BSYH:858:STOP_FAULT_B") #! Field("BTM:BSYH:858:STOP_FAULT_B.VAL",16777215,1,"BTM:BSYH:858:STOP_FAULT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi133") { field(DESC, "Port D2_RDB bit 133") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 133, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYH:1:SR_STD2_IN_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_IN_OK_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi133 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_IN_OK_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_IN_OK_B") { field(DESC, "Safety Relay D2 IN OK B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb133",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb133") #! Field("PLC:BSY0:PP06:D2_RDBb133.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb133.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb133.FLNK","STPR:BSYH:1:SR_STD2_IN_OK_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb133.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb133.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_B_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_IN_OK_B_calc") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_B_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_IN_OK_B_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb133.VAL") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_B_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_B_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_B_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_B_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_B_calc.OUT","STPR:BSYH:1:SR_STD2_IN_OK_B.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_B",500,20,0,0,"STPR:BSYH:1:SR_STD2_IN_OK_B") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_B.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi132") { field(DESC, "Port D2_RDB bit 132") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 132, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYH:1:SR_STD2_OUT_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_OUT_OK_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi132 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_OUT_OK_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_OUT_OK_B") { field(DESC, "Safety Relay D2 OUT OK B") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb132",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb132") #! Field("PLC:BSY0:PP06:D2_RDBb132.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb132.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb132.FLNK","STPR:BSYH:1:SR_STD2_OUT_OK_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb132.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb132.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_B_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_OUT_OK_B_calc") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb132.VAL") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_B_calc.OUT","STPR:BSYH:1:SR_STD2_OUT_OK_B.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_B",500,20,0,0,"STPR:BSYH:1:SR_STD2_OUT_OK_B") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_B.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi143") { field(DESC, "Port D2_RDB bit 143") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 143, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi143 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:BSYH:1:STD2:STOP_FAULT_LTH_B") { field(DESC, "D2 Stopper Fault Lat B") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb143",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb143") #! Field("PLC:BSY0:PP06:D2_RDBb143.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb143.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb143.FLNK","PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb143.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb143.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc",260,18,0,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.INPA") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb143.VAL") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.INPB") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.OUT") #! Link("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B_calc.OUT","PPS:BSYH:1:STD2:STOP_FAULT_LTH_B.VAL") #! Record("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B",500,20,0,0,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_B") #! Field("PPS:BSYH:1:STD2:STOP_FAULT_LTH_B.VAL",16777215,1,"PPS:BSYH:1:STD2:STOP_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi142") { field(DESC, "Port D2_RDB bit 142") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 142, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "STPR:BSYH:854:STOP_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:854:STOP_FAULT_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi142 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:854:STOP_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:854:STOP_FAULT_LTH_B") { field(DESC, "ST60 Stopper Fault Lat B") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb142",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb142") #! Field("PLC:BSY0:PP06:D2_RDBb142.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb142.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb142.FLNK","STPR:BSYH:854:STOP_FAULT_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb142.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb142.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_LTH_B_calc",260,18,0,1,"STPR:BSYH:854:STOP_FAULT_LTH_B_calc") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_B_calc.INPA",16777215,0,"STPR:BSYH:854:STOP_FAULT_LTH_B_calc.INPA") #! Link("STPR:BSYH:854:STOP_FAULT_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb142.VAL") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_B_calc.INPB",16777215,1,"STPR:BSYH:854:STOP_FAULT_LTH_B_calc.INPB") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_B_calc.OUT",16777215,1,"STPR:BSYH:854:STOP_FAULT_LTH_B_calc.OUT") #! Link("STPR:BSYH:854:STOP_FAULT_LTH_B_calc.OUT","STPR:BSYH:854:STOP_FAULT_LTH_B.VAL") #! Record("STPR:BSYH:854:STOP_FAULT_LTH_B",500,20,0,0,"STPR:BSYH:854:STOP_FAULT_LTH_B") #! Field("STPR:BSYH:854:STOP_FAULT_LTH_B.VAL",16777215,1,"STPR:BSYH:854:STOP_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi141") { field(DESC, "Port D2_RDB bit 141") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 141, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "STPR:BSYH:905:STOP_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:905:STOP_FAULT_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi141 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:905:STOP_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:905:STOP_FAULT_LTH_B") { field(DESC, "ST61 Stopper Fault Lat B") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb141",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb141") #! Field("PLC:BSY0:PP06:D2_RDBb141.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb141.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb141.FLNK","STPR:BSYH:905:STOP_FAULT_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb141.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb141.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_LTH_B_calc",260,18,0,1,"STPR:BSYH:905:STOP_FAULT_LTH_B_calc") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_B_calc.INPA",16777215,0,"STPR:BSYH:905:STOP_FAULT_LTH_B_calc.INPA") #! Link("STPR:BSYH:905:STOP_FAULT_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb141.VAL") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_B_calc.INPB",16777215,1,"STPR:BSYH:905:STOP_FAULT_LTH_B_calc.INPB") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_B_calc.OUT",16777215,1,"STPR:BSYH:905:STOP_FAULT_LTH_B_calc.OUT") #! Link("STPR:BSYH:905:STOP_FAULT_LTH_B_calc.OUT","STPR:BSYH:905:STOP_FAULT_LTH_B.VAL") #! Record("STPR:BSYH:905:STOP_FAULT_LTH_B",500,20,0,0,"STPR:BSYH:905:STOP_FAULT_LTH_B") #! Field("STPR:BSYH:905:STOP_FAULT_LTH_B.VAL",16777215,1,"STPR:BSYH:905:STOP_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi140") { field(DESC, "Port D2_RDB bit 140") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 140, 1, 1)") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(FLNK, "BTM:BSYH:858:STOP_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "BTM:BSYH:858:STOP_FAULT_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi140 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BTM:BSYH:858:STOP_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "BTM:BSYH:858:STOP_FAULT_LTH_B") { field(DESC, "DM60 Stopper Fault Lat B") field(ZNAM, "Latched") field(ONAM, "Not_Latched") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb140",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb140") #! Field("PLC:BSY0:PP06:D2_RDBb140.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb140.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb140.FLNK","BTM:BSYH:858:STOP_FAULT_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb140.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb140.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_LTH_B_calc",260,18,0,1,"BTM:BSYH:858:STOP_FAULT_LTH_B_calc") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_B_calc.INPA",16777215,0,"BTM:BSYH:858:STOP_FAULT_LTH_B_calc.INPA") #! Link("BTM:BSYH:858:STOP_FAULT_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb140.VAL") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_B_calc.INPB",16777215,1,"BTM:BSYH:858:STOP_FAULT_LTH_B_calc.INPB") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_B_calc.OUT",16777215,1,"BTM:BSYH:858:STOP_FAULT_LTH_B_calc.OUT") #! Link("BTM:BSYH:858:STOP_FAULT_LTH_B_calc.OUT","BTM:BSYH:858:STOP_FAULT_LTH_B.VAL") #! Record("BTM:BSYH:858:STOP_FAULT_LTH_B",500,20,0,0,"BTM:BSYH:858:STOP_FAULT_LTH_B") #! Field("BTM:BSYH:858:STOP_FAULT_LTH_B.VAL",16777215,1,"BTM:BSYH:858:STOP_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi139") { field(DESC, "Port D2_RDB bit 139") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 139, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi139 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_IN_OK_LTH_B") { field(DESC, "Safety Relay D2 IN OK Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb139",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb139") #! Field("PLC:BSY0:PP06:D2_RDBb139.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb139.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb139.FLNK","STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb139.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb139.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb139.VAL") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B_calc.OUT","STPR:BSYH:1:SR_STD2_IN_OK_LTH_B.VAL") #! Record("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B",500,20,0,0,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_B") #! Field("STPR:BSYH:1:SR_STD2_IN_OK_LTH_B.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_IN_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:BSY0:PP06:Bi138") { field(DESC, "Port D2_RDB bit 138") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 138, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc") { field(INPA, "PLC:BSY0:PP06:Bi138 NPP MS") field(INPB, "PLC:BSY0:PP06:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B") { field(DESC, "Safety Relay D2 OUT OK Lat B") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:BSY0:PP06:D2_RDBb138",20,19,0,0,"PLC:BSY0:PP06:D2_RDBb138") #! Field("PLC:BSY0:PP06:D2_RDBb138.FLNK",16777215,1,"PLC:BSY0:PP06:D2_RDBb138.FLNK") #! Link("PLC:BSY0:PP06:D2_RDBb138.FLNK","STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc") #! Field("PLC:BSY0:PP06:D2_RDBb138.VAL",16777215,0,"PLC:BSY0:PP06:D2_RDBb138.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc",260,18,0,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.INPA",16777215,0,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.INPA") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.INPA","PLC:BSY0:PP06:D2_RDBb138.VAL") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.INPB",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.INPB") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.OUT",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.OUT") #! Link("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B_calc.OUT","STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B.VAL") #! Record("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B",500,20,0,0,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B") #! Field("STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B.VAL",16777215,1,"STPR:BSYH:1:SR_STD2_OUT_OK_LTH_B.VAL") record(bo, "PPS:BSYH:1:STD2:RESET_INTLK_B") { field(DESC, "STD2_Interlock_Reset_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STD2:PAUSEHB_B") { field(DESC, "STD2_Pause_Heartbeat_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STPRBTHINSET_B") { field(DESC, "Send_STD2_Set_In_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 5, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STPRBTHOUTST_B") { field(DESC, "Send_STD2_Set_Out_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 4, 1, 1)") field(ZNAM, "False") field(ONAM, "True") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:BSY0:PP06:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:BSY0:PP06:TABLE_CYCLER") { field( OUT, "PLC:BSY0:PP06:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:BSY0:PP06:SEG_CYCLER") { field( OUT, "PLC:BSY0:PP06:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:BSY0:PP06:TABLE_9_SEG_1") { field( INPA, "PLC:BSY0:PP06:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP06:REQ_SEG CP") field( INPC, "PLC:BSY0:PP06:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP06:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:BSY0:PP06:TABLE_1_SEG_1") { field( INPA, "PLC:BSY0:PP06:REQ_TABLE CP") field( INPB, "PLC:BSY0:PP06:REQ_SEG CP") field( INPC, "PLC:BSY0:PP06:REQ_TABLE_IN CP") field( INPD, "PLC:BSY0:PP06:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP06:REQ_TABLE_OUT") { field(OUTA, "PLC:BSY0:PP06:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP06:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP06:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP06:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP06:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP06:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP06:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP06:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP06:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT0 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT1 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT2 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT3 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT4 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT5 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT6 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_TABLE_OUT") field(INPB, "PLC:BSY0:PP06:TABLE_BIT7 MS") field(INPC, "PLC:BSY0:PP06:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP06:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:BSY0:PP06:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:BSY0:PP06:TABLE_BIT0 CP MS") field(INPB, "PLC:BSY0:PP06:TABLE_BIT1 CP MS") field(INPC, "PLC:BSY0:PP06:TABLE_BIT2 CP MS") field(INPD, "PLC:BSY0:PP06:TABLE_BIT3 CP MS") field(INPE, "PLC:BSY0:PP06:TABLE_BIT4 CP MS") field(INPF, "PLC:BSY0:PP06:TABLE_BIT5 CP MS") field(INPG, "PLC:BSY0:PP06:TABLE_BIT6 CP MS") field(INPH, "PLC:BSY0:PP06:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP06:REQ_TABLE PP MS") #field(SDIS, "PLC:BSY0:PP06:REQ_TABLE_OUT.PACT") } record(longout, "PLC:BSY0:PP06:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:BSY0:PP06:REQ_SEG_OUT") { field(OUTA, "PLC:BSY0:PP06:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:BSY0:PP06:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:BSY0:PP06:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:BSY0:PP06:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:BSY0:PP06:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:BSY0:PP06:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:BSY0:PP06:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:BSY0:PP06:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:BSY0:PP06:REQ_SEG_IN.PACT") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT0 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT1 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT1 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT2 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT2 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT3 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT3 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT4 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT4 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT5 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT5 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT6 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT6 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:BSY0:PP06:REQ_SEG_OUT") field(INPB, "PLC:BSY0:PP06:SEG_BIT7 MS") field(INPC, "PLC:BSY0:PP06:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:BSY0:PP06:REQ_SEG_BIT7 PP") } record(calcout, "PLC:BSY0:PP06:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:BSY0:PP06:SEG_BIT0 CP MS") field(INPB, "PLC:BSY0:PP06:SEG_BIT1 CP MS") field(INPC, "PLC:BSY0:PP06:SEG_BIT2 CP MS") field(INPD, "PLC:BSY0:PP06:SEG_BIT3 CP MS") field(INPE, "PLC:BSY0:PP06:SEG_BIT4 CP MS") field(INPF, "PLC:BSY0:PP06:SEG_BIT5 CP MS") field(INPG, "PLC:BSY0:PP06:SEG_BIT6 CP MS") field(INPH, "PLC:BSY0:PP06:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:BSY0:PP06:REQ_SEG PP MS") field(SDIS, "PLC:BSY0:PP06:REQ_SEG_OUT.PACT") } record(bi, "PLC:BSY0:PP06:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:BSY0:PP06:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_RDB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:BSY0:PP06:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(D2_WRTB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:BSY0:PP06:w0") { field(DESC, "D2 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:w1") { field(DESC, "D2 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 2, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP06:CHECKSUM_SDIS") { field(INPA, "PLC:BSY0:PP06:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:BSY0:PP06:w3") { field(DESC, "D2 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 3, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP06:CHECKSUM_SAFE_calc") { field(INPA, "PLC:BSY0:PP06:w3 PP MS") field(INPB, "PLC:BSY0:PP06:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP06:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:BSY0:PP06:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP06:w4") { field(DESC, "D2 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 4, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP06:PROJ_CHECKSUM_calc") { field(INPA, "PLC:BSY0:PP06:w4 NPP MS") field(INPB, "PLC:BSY0:PP06:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP06:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP06:w5") { field(DESC, "D2 PLC Checksum CHB") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 5, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP06:DAY_MONTH_calc") { field(INPA, "PLC:BSY0:PP06:w5 NPP MS") field(INPB, "PLC:BSY0:PP06:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP06:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP06:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:BSY0:PP06:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:BSY0:PP06:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:BSY0:PP06:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP06:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 6, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP06:PROJ_YEAR_calc") { field(INPA, "PLC:BSY0:PP06:w6 NPP MS") field(INPB, "PLC:BSY0:PP06:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP06:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:BSY0:PP06:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 7, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP06:OP_HRS_MSB_calc") { field(INPA, "PLC:BSY0:PP06:w7 NPP MS") field(INPB, "PLC:BSY0:PP06:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP06:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(D2_WDB, 8, 0xFFFF, 1)") field(FLNK, "PLC:BSY0:PP06:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:BSY0:PP06:OP_HRS_LSB_calc") { field(INPA, "PLC:BSY0:PP06:w8 NPP MS") field(INPB, "PLC:BSY0:PP06:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:BSY0:PP06:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:BSY0:PP06:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:BSY0:PP06:OP_HOURS") { field(INPA, "PLC:BSY0:PP06:OP_HRS_MSB CP MS") field(INPB, "PLC:BSY0:PP06:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:BSY0:PP06:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:BSY0:PP06:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:BSY0:PP06:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(D2_RDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP06:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP06:RDHist.PROC") } record(waveform,"PLC:BSY0:PP06:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_RDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP06:RDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP06:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_RDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP06:RDReadOK.PROC") } record(longout,"PLC:BSY0:PP06:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(D2_RDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP06:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP06:RDWriteOK.PROC") } record(longin,"PLC:BSY0:PP06:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP06:RDIOErrors.PROC") } record(longin,"PLC:BSY0:PP06:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP06:RDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP06:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP06:RDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP06:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_RDB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP06:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(D2_WRTB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP06:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP06:WRTHist.PROC") } record(waveform,"PLC:BSY0:PP06:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WRTB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP06:WRTHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP06:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WRTB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP06:WRTReadOK.PROC") } record(longout,"PLC:BSY0:PP06:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(D2_WRTB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP06:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTB 0)READ_OK") field(FLNK,"PLC:BSY0:PP06:WRTWriteOK.PROC") } record(longin,"PLC:BSY0:PP06:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP06:WRTIOErrors.PROC") } record(longin,"PLC:BSY0:PP06:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP06:WRTLastIOTime.PROC") } record(longin,"PLC:BSY0:PP06:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP06:WRTMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP06:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WRTB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:BSY0:PP06:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(D2_WDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:BSY0:PP06:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:BSY0:PP06:WDHist.PROC") } record(waveform,"PLC:BSY0:PP06:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP06:WDHistTimeAxis.PROC") } record(waveform,"PLC:BSY0:PP06:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(D2_WDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:BSY0:PP06:WDReadOK.PROC") } record(longout,"PLC:BSY0:PP06:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(D2_WDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:BSY0:PP06:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDB 0)READ_OK") field(FLNK,"PLC:BSY0:PP06:WDWriteOK.PROC") } record(longin,"PLC:BSY0:PP06:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDB 0)WRITE_OK") field(FLNK,"PLC:BSY0:PP06:WDIOErrors.PROC") } record(longin,"PLC:BSY0:PP06:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDB 0)IO_ERRORS") field(FLNK,"PLC:BSY0:PP06:WDLastIOTime.PROC") } record(longin,"PLC:BSY0:PP06:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDB 0)LAST_IO_TIME") field(FLNK,"PLC:BSY0:PP06:WDMaxIOTime.PROC") } record(longin,"PLC:BSY0:PP06:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(D2_WDB 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi7") { field(DESC, "Port CLTS_RDA bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 7, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:CLTS:1:HW_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HW_ENABLE_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi7 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HW_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HW_ENABLE_A") { field(DESC, "RT-IN HW Enable") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb7",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb7") #! Field("PLC:CLTS:PP13:CLTS_RDAb7.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb7.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb7.FLNK","PPS:CLTS:1:HW_ENABLE_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb7.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb7.VAL") #! Record("PPS:CLTS:1:HW_ENABLE_A_calc",260,18,0,1,"PPS:CLTS:1:HW_ENABLE_A_calc") #! Field("PPS:CLTS:1:HW_ENABLE_A_calc.INPA",16777215,0,"PPS:CLTS:1:HW_ENABLE_A_calc.INPA") #! Link("PPS:CLTS:1:HW_ENABLE_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb7.VAL") #! Field("PPS:CLTS:1:HW_ENABLE_A_calc.INPB",16777215,1,"PPS:CLTS:1:HW_ENABLE_A_calc.INPB") #! Field("PPS:CLTS:1:HW_ENABLE_A_calc.OUT",16777215,1,"PPS:CLTS:1:HW_ENABLE_A_calc.OUT") #! Link("PPS:CLTS:1:HW_ENABLE_A_calc.OUT","PPS:CLTS:1:HW_ENABLE_A.VAL") #! Record("PPS:CLTS:1:HW_ENABLE_A",500,20,0,0,"PPS:CLTS:1:HW_ENABLE_A") #! Field("PPS:CLTS:1:HW_ENABLE_A.VAL",16777215,1,"PPS:CLTS:1:HW_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi6") { field(DESC, "Port CLTS_RDA bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 6, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:KICK_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_OFF_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi6 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_OFF_A") { field(DESC, "RT-IN CL-Kicker OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb6",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb6") #! Field("PLC:CLTS:PP13:CLTS_RDAb6.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb6.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb6.FLNK","PPS:CLTS:3:KICK_OFF_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb6.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb6.VAL") #! Record("PPS:CLTS:3:KICK_OFF_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_OFF_A_calc") #! Field("PPS:CLTS:3:KICK_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_OFF_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_OFF_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb6.VAL") #! Field("PPS:CLTS:3:KICK_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_OFF_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_OFF_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_OFF_A_calc.OUT","PPS:CLTS:3:KICK_OFF_A.VAL") #! Record("PPS:CLTS:3:KICK_OFF_A",500,20,0,0,"PPS:CLTS:3:KICK_OFF_A") #! Field("PPS:CLTS:3:KICK_OFF_A.VAL",16777215,1,"PPS:CLTS:3:KICK_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi5") { field(DESC, "Port CLTS_RDA bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 5, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:DCBEND_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_OFF_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi5 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_OFF_A") { field(DESC, "RT-IN CL-DC OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb5",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb5") #! Field("PLC:CLTS:PP13:CLTS_RDAb5.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb5.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb5.FLNK","PPS:CLTS:3:DCBEND_OFF_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb5.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb5.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_OFF_A_calc") #! Field("PPS:CLTS:3:DCBEND_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_OFF_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_OFF_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb5.VAL") #! Field("PPS:CLTS:3:DCBEND_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_OFF_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_OFF_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_OFF_A_calc.OUT","PPS:CLTS:3:DCBEND_OFF_A.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_A",500,20,0,0,"PPS:CLTS:3:DCBEND_OFF_A") #! Field("PPS:CLTS:3:DCBEND_OFF_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi4") { field(DESC, "Port CLTS_RDA bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 4, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:SEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_OFF_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi4 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_OFF_A") { field(DESC, "RT-IN CL-Septum OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb4",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb4") #! Field("PLC:CLTS:PP13:CLTS_RDAb4.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb4.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb4.FLNK","PPS:CLTS:3:SEP_OFF_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb4.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb4.VAL") #! Record("PPS:CLTS:3:SEP_OFF_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_OFF_A_calc") #! Field("PPS:CLTS:3:SEP_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_OFF_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_OFF_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb4.VAL") #! Field("PPS:CLTS:3:SEP_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_OFF_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_OFF_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_OFF_A_calc.OUT","PPS:CLTS:3:SEP_OFF_A.VAL") #! Record("PPS:CLTS:3:SEP_OFF_A",500,20,0,0,"PPS:CLTS:3:SEP_OFF_A") #! Field("PPS:CLTS:3:SEP_OFF_A.VAL",16777215,1,"PPS:CLTS:3:SEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi3") { field(DESC, "Port CLTS_RDA bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 3, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:MERGE_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_OFF_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi3 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_OFF_A") { field(DESC, "RT-IN CL-Merge OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb3",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb3") #! Field("PLC:CLTS:PP13:CLTS_RDAb3.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb3.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb3.FLNK","PPS:CLTS:3:MERGE_OFF_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb3.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb3.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_OFF_A_calc") #! Field("PPS:CLTS:3:MERGE_OFF_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_OFF_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_OFF_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb3.VAL") #! Field("PPS:CLTS:3:MERGE_OFF_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_OFF_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_OFF_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_OFF_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_OFF_A_calc.OUT","PPS:CLTS:3:MERGE_OFF_A.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_A",500,20,0,0,"PPS:CLTS:3:MERGE_OFF_A") #! Field("PPS:CLTS:3:MERGE_OFF_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi2") { field(DESC, "Port CLTS_RDA bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 2, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI28:3:HXR:KICKSEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:3:HXR:KICKSEP_OFF_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi2 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:3:HXR:KICKSEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:3:HXR:KICKSEP_OFF_A") { field(DESC, "RT-IN HX-KickerSepMrg Summary OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb2",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb2") #! Field("PLC:CLTS:PP13:CLTS_RDAb2.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb2.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb2.FLNK","PPS:LI28:3:HXR:KICKSEP_OFF_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb2.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb2.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_A_calc",260,18,0,1,"PPS:LI28:3:HXR:KICKSEP_OFF_A_calc") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.INPA",16777215,0,"PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.INPA") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb2.VAL") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.INPB",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.INPB") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.OUT",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.OUT") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_A_calc.OUT","PPS:LI28:3:HXR:KICKSEP_OFF_A.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_A",500,20,0,0,"PPS:LI28:3:HXR:KICKSEP_OFF_A") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_A.VAL",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi1") { field(DESC, "Port CLTS_RDA bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 1, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI30:3:SXR:KICKSEP_OFF_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:3:SXR:KICKSEP_OFF_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi1 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:3:SXR:KICKSEP_OFF_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:3:SXR:KICKSEP_OFF_A") { field(DESC, "RT-IN SX-KickerSepMrg Summary OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb1",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb1") #! Field("PLC:CLTS:PP13:CLTS_RDAb1.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb1.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb1.FLNK","PPS:LI30:3:SXR:KICKSEP_OFF_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb1.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb1.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_A_calc",260,18,0,1,"PPS:LI30:3:SXR:KICKSEP_OFF_A_calc") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.INPA",16777215,0,"PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.INPA") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb1.VAL") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.INPB",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.INPB") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.OUT",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.OUT") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_A_calc.OUT","PPS:LI30:3:SXR:KICKSEP_OFF_A.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_A",500,20,0,0,"PPS:LI30:3:SXR:KICKSEP_OFF_A") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_A.VAL",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi0") { field(DESC, "Port CLTS_RDA bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 0, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:CLTS:585:3:IN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:3:IN_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi0 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:3:IN_A PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:3:IN_A") { field(DESC, "RT-IN STP-CLTS IN") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb0",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb0") #! Field("PLC:CLTS:PP13:CLTS_RDAb0.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb0.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb0.FLNK","STPR:CLTS:585:3:IN_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb0.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb0.VAL") #! Record("STPR:CLTS:585:3:IN_A_calc",260,18,0,1,"STPR:CLTS:585:3:IN_A_calc") #! Field("STPR:CLTS:585:3:IN_A_calc.INPA",16777215,0,"STPR:CLTS:585:3:IN_A_calc.INPA") #! Link("STPR:CLTS:585:3:IN_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb0.VAL") #! Field("STPR:CLTS:585:3:IN_A_calc.INPB",16777215,1,"STPR:CLTS:585:3:IN_A_calc.INPB") #! Field("STPR:CLTS:585:3:IN_A_calc.OUT",16777215,1,"STPR:CLTS:585:3:IN_A_calc.OUT") #! Link("STPR:CLTS:585:3:IN_A_calc.OUT","STPR:CLTS:585:3:IN_A.VAL") #! Record("STPR:CLTS:585:3:IN_A",500,20,0,0,"STPR:CLTS:585:3:IN_A") #! Field("STPR:CLTS:585:3:IN_A.VAL",16777215,1,"STPR:CLTS:585:3:IN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi15") { field(DESC, "Port CLTS_RDA bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYS:3:ST34_OUT_SUM_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:3:ST34_OUT_SUM_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi15 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:3:ST34_OUT_SUM_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:3:ST34_OUT_SUM_A") { field(DESC, "RT-IN STP-34 Summary OUT") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb15",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb15") #! Field("PLC:CLTS:PP13:CLTS_RDAb15.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb15.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb15.FLNK","STPR:BSYS:3:ST34_OUT_SUM_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb15.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb15.VAL") #! Record("STPR:BSYS:3:ST34_OUT_SUM_A_calc",260,18,0,1,"STPR:BSYS:3:ST34_OUT_SUM_A_calc") #! Field("STPR:BSYS:3:ST34_OUT_SUM_A_calc.INPA",16777215,0,"STPR:BSYS:3:ST34_OUT_SUM_A_calc.INPA") #! Link("STPR:BSYS:3:ST34_OUT_SUM_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb15.VAL") #! Field("STPR:BSYS:3:ST34_OUT_SUM_A_calc.INPB",16777215,1,"STPR:BSYS:3:ST34_OUT_SUM_A_calc.INPB") #! Field("STPR:BSYS:3:ST34_OUT_SUM_A_calc.OUT",16777215,1,"STPR:BSYS:3:ST34_OUT_SUM_A_calc.OUT") #! Link("STPR:BSYS:3:ST34_OUT_SUM_A_calc.OUT","STPR:BSYS:3:ST34_OUT_SUM_A.VAL") #! Record("STPR:BSYS:3:ST34_OUT_SUM_A",500,20,0,0,"STPR:BSYS:3:ST34_OUT_SUM_A") #! Field("STPR:BSYS:3:ST34_OUT_SUM_A.VAL",16777215,1,"STPR:BSYS:3:ST34_OUT_SUM_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi14") { field(DESC, "Port CLTS_RDA bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HRTBT_INP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_INP_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi14 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_INP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_INP_A") { field(DESC, "RT-IN Heartbeat IN from opposite chain") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb14",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb14") #! Field("PLC:CLTS:PP13:CLTS_RDAb14.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb14.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb14.FLNK","PPS:CLTS:1:HRTBT_INP_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb14.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb14.VAL") #! Record("PPS:CLTS:1:HRTBT_INP_A_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_INP_A_calc") #! Field("PPS:CLTS:1:HRTBT_INP_A_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_INP_A_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_INP_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb14.VAL") #! Field("PPS:CLTS:1:HRTBT_INP_A_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_INP_A_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_INP_A_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_INP_A_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_INP_A_calc.OUT","PPS:CLTS:1:HRTBT_INP_A.VAL") #! Record("PPS:CLTS:1:HRTBT_INP_A",500,20,0,0,"PPS:CLTS:1:HRTBT_INP_A") #! Field("PPS:CLTS:1:HRTBT_INP_A.VAL",16777215,1,"PPS:CLTS:1:HRTBT_INP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi13") { field(DESC, "Port CLTS_RDA bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 13, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:ACR_ENABLE_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:ACR_ENABLE_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi13 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:ACR_ENABLE_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:ACR_ENABLE_A") { field(DESC, "RT-IN CLTS Admin Enable (jumpered)") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb13",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb13") #! Field("PLC:CLTS:PP13:CLTS_RDAb13.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb13.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb13.FLNK","PPS:CLTS:1:ACR_ENABLE_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb13.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb13.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_A_calc",260,18,0,1,"PPS:CLTS:1:ACR_ENABLE_A_calc") #! Field("PPS:CLTS:1:ACR_ENABLE_A_calc.INPA",16777215,0,"PPS:CLTS:1:ACR_ENABLE_A_calc.INPA") #! Link("PPS:CLTS:1:ACR_ENABLE_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb13.VAL") #! Field("PPS:CLTS:1:ACR_ENABLE_A_calc.INPB",16777215,1,"PPS:CLTS:1:ACR_ENABLE_A_calc.INPB") #! Field("PPS:CLTS:1:ACR_ENABLE_A_calc.OUT",16777215,1,"PPS:CLTS:1:ACR_ENABLE_A_calc.OUT") #! Link("PPS:CLTS:1:ACR_ENABLE_A_calc.OUT","PPS:CLTS:1:ACR_ENABLE_A.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_A",500,20,0,0,"PPS:CLTS:1:ACR_ENABLE_A") #! Field("PPS:CLTS:1:ACR_ENABLE_A.VAL",16777215,1,"PPS:CLTS:1:ACR_ENABLE_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi12") { field(DESC, "Port CLTS_RDA bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HW_RESET_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HW_RESET_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi12 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HW_RESET_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HW_RESET_A") { field(DESC, "RT-IN HW Reset") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb12",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb12") #! Field("PLC:CLTS:PP13:CLTS_RDAb12.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb12.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb12.FLNK","PPS:CLTS:1:HW_RESET_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb12.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb12.VAL") #! Record("PPS:CLTS:1:HW_RESET_A_calc",260,18,0,1,"PPS:CLTS:1:HW_RESET_A_calc") #! Field("PPS:CLTS:1:HW_RESET_A_calc.INPA",16777215,0,"PPS:CLTS:1:HW_RESET_A_calc.INPA") #! Link("PPS:CLTS:1:HW_RESET_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb12.VAL") #! Field("PPS:CLTS:1:HW_RESET_A_calc.INPB",16777215,1,"PPS:CLTS:1:HW_RESET_A_calc.INPB") #! Field("PPS:CLTS:1:HW_RESET_A_calc.OUT",16777215,1,"PPS:CLTS:1:HW_RESET_A_calc.OUT") #! Link("PPS:CLTS:1:HW_RESET_A_calc.OUT","PPS:CLTS:1:HW_RESET_A.VAL") #! Record("PPS:CLTS:1:HW_RESET_A",500,20,0,0,"PPS:CLTS:1:HW_RESET_A") #! Field("PPS:CLTS:1:HW_RESET_A.VAL",16777215,1,"PPS:CLTS:1:HW_RESET_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi11") { field(DESC, "Port CLTS_RDA bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 11, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:KICK_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_INTLK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi11 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_INTLK_A") { field(DESC, "RT-IN CL Kicker Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb11",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb11") #! Field("PLC:CLTS:PP13:CLTS_RDAb11.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb11.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb11.FLNK","PPS:CLTS:3:KICK_INTLK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb11.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb11.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_INTLK_A_calc") #! Field("PPS:CLTS:3:KICK_INTLK_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_INTLK_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_INTLK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb11.VAL") #! Field("PPS:CLTS:3:KICK_INTLK_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_INTLK_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_INTLK_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_INTLK_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_INTLK_A_calc.OUT","PPS:CLTS:3:KICK_INTLK_A.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_A",500,20,0,0,"PPS:CLTS:3:KICK_INTLK_A") #! Field("PPS:CLTS:3:KICK_INTLK_A.VAL",16777215,1,"PPS:CLTS:3:KICK_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi10") { field(DESC, "Port CLTS_RDA bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 10, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:DCBEND_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_INTLK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi10 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_INTLK_A") { field(DESC, "RT-IN CL DC Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb10",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb10") #! Field("PLC:CLTS:PP13:CLTS_RDAb10.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb10.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb10.FLNK","PPS:CLTS:3:DCBEND_INTLK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb10.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb10.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_INTLK_A_calc") #! Field("PPS:CLTS:3:DCBEND_INTLK_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_INTLK_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_INTLK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb10.VAL") #! Field("PPS:CLTS:3:DCBEND_INTLK_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_INTLK_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_INTLK_A_calc.OUT","PPS:CLTS:3:DCBEND_INTLK_A.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_A",500,20,0,0,"PPS:CLTS:3:DCBEND_INTLK_A") #! Field("PPS:CLTS:3:DCBEND_INTLK_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi9") { field(DESC, "Port CLTS_RDA bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 9, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:SEP_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_INTLK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi9 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_INTLK_A") { field(DESC, "RT-IN CL Septum Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb9",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb9") #! Field("PLC:CLTS:PP13:CLTS_RDAb9.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb9.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb9.FLNK","PPS:CLTS:3:SEP_INTLK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb9.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb9.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_INTLK_A_calc") #! Field("PPS:CLTS:3:SEP_INTLK_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_INTLK_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_INTLK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb9.VAL") #! Field("PPS:CLTS:3:SEP_INTLK_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_INTLK_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_INTLK_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_INTLK_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_INTLK_A_calc.OUT","PPS:CLTS:3:SEP_INTLK_A.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_A",500,20,0,0,"PPS:CLTS:3:SEP_INTLK_A") #! Field("PPS:CLTS:3:SEP_INTLK_A.VAL",16777215,1,"PPS:CLTS:3:SEP_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi8") { field(DESC, "Port CLTS_RDA bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 8, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:MERGE_INTLK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_INTLK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi8 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_INTLK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_INTLK_A") { field(DESC, "RT-IN CL Merge Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb8",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb8") #! Field("PLC:CLTS:PP13:CLTS_RDAb8.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb8.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb8.FLNK","PPS:CLTS:3:MERGE_INTLK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb8.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb8.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_INTLK_A_calc") #! Field("PPS:CLTS:3:MERGE_INTLK_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_INTLK_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_INTLK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb8.VAL") #! Field("PPS:CLTS:3:MERGE_INTLK_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_INTLK_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_INTLK_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_INTLK_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_INTLK_A_calc.OUT","PPS:CLTS:3:MERGE_INTLK_A.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_A",500,20,0,0,"PPS:CLTS:3:MERGE_INTLK_A") #! Field("PPS:CLTS:3:MERGE_INTLK_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_INTLK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi89") { field(DESC, "Port CLTS_RDA bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 89, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:KICK_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_ON_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi89 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_ON_A") { field(DESC, "RT-OUT CL-Kicker ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb89",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb89") #! Field("PLC:CLTS:PP13:CLTS_RDAb89.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb89.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb89.FLNK","PPS:CLTS:3:KICK_ON_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb89.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb89.VAL") #! Record("PPS:CLTS:3:KICK_ON_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_ON_A_calc") #! Field("PPS:CLTS:3:KICK_ON_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_ON_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_ON_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb89.VAL") #! Field("PPS:CLTS:3:KICK_ON_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_ON_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_ON_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_ON_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_ON_A_calc.OUT","PPS:CLTS:3:KICK_ON_A.VAL") #! Record("PPS:CLTS:3:KICK_ON_A",500,20,0,0,"PPS:CLTS:3:KICK_ON_A") #! Field("PPS:CLTS:3:KICK_ON_A.VAL",16777215,1,"PPS:CLTS:3:KICK_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi88") { field(DESC, "Port CLTS_RDA bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 88, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:DCBEND_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_ON_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi88 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_ON_A") { field(DESC, "RT-OUT CL-DC ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb88",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb88") #! Field("PLC:CLTS:PP13:CLTS_RDAb88.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb88.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb88.FLNK","PPS:CLTS:3:DCBEND_ON_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb88.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb88.VAL") #! Record("PPS:CLTS:3:DCBEND_ON_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_ON_A_calc") #! Field("PPS:CLTS:3:DCBEND_ON_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_ON_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_ON_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb88.VAL") #! Field("PPS:CLTS:3:DCBEND_ON_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_ON_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_ON_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_ON_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_ON_A_calc.OUT","PPS:CLTS:3:DCBEND_ON_A.VAL") #! Record("PPS:CLTS:3:DCBEND_ON_A",500,20,0,0,"PPS:CLTS:3:DCBEND_ON_A") #! Field("PPS:CLTS:3:DCBEND_ON_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi103") { field(DESC, "Port CLTS_RDA bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 103, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:SEP_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_ON_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi103 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_ON_A") { field(DESC, "RT-OUT CL-Septum ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb103",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb103") #! Field("PLC:CLTS:PP13:CLTS_RDAb103.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb103.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb103.FLNK","PPS:CLTS:3:SEP_ON_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb103.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb103.VAL") #! Record("PPS:CLTS:3:SEP_ON_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_ON_A_calc") #! Field("PPS:CLTS:3:SEP_ON_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_ON_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_ON_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb103.VAL") #! Field("PPS:CLTS:3:SEP_ON_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_ON_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_ON_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_ON_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_ON_A_calc.OUT","PPS:CLTS:3:SEP_ON_A.VAL") #! Record("PPS:CLTS:3:SEP_ON_A",500,20,0,0,"PPS:CLTS:3:SEP_ON_A") #! Field("PPS:CLTS:3:SEP_ON_A.VAL",16777215,1,"PPS:CLTS:3:SEP_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi102") { field(DESC, "Port CLTS_RDA bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 102, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:MERGE_ON_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_ON_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi102 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_ON_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_ON_A") { field(DESC, "RT-OUT CL-Merge ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb102",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb102") #! Field("PLC:CLTS:PP13:CLTS_RDAb102.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb102.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb102.FLNK","PPS:CLTS:3:MERGE_ON_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb102.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb102.VAL") #! Record("PPS:CLTS:3:MERGE_ON_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_ON_A_calc") #! Field("PPS:CLTS:3:MERGE_ON_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_ON_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_ON_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb102.VAL") #! Field("PPS:CLTS:3:MERGE_ON_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_ON_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_ON_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_ON_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_ON_A_calc.OUT","PPS:CLTS:3:MERGE_ON_A.VAL") #! Record("PPS:CLTS:3:MERGE_ON_A",500,20,0,0,"PPS:CLTS:3:MERGE_ON_A") #! Field("PPS:CLTS:3:MERGE_ON_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_ON_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi101") { field(DESC, "Port CLTS_RDA bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 101, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:KICK_PERMIT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_PERMIT_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi101 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_PERMIT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_PERMIT_A") { field(DESC, "RT-OUT CL-Kicker Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb101",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb101") #! Field("PLC:CLTS:PP13:CLTS_RDAb101.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb101.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb101.FLNK","PPS:CLTS:3:KICK_PERMIT_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb101.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb101.VAL") #! Record("PPS:CLTS:3:KICK_PERMIT_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_PERMIT_A_calc") #! Field("PPS:CLTS:3:KICK_PERMIT_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_PERMIT_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_PERMIT_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb101.VAL") #! Field("PPS:CLTS:3:KICK_PERMIT_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_PERMIT_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_PERMIT_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_PERMIT_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_PERMIT_A_calc.OUT","PPS:CLTS:3:KICK_PERMIT_A.VAL") #! Record("PPS:CLTS:3:KICK_PERMIT_A",500,20,0,0,"PPS:CLTS:3:KICK_PERMIT_A") #! Field("PPS:CLTS:3:KICK_PERMIT_A.VAL",16777215,1,"PPS:CLTS:3:KICK_PERMIT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi100") { field(DESC, "Port CLTS_RDA bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 100, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:DCBEND_PERMIT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_PERMIT_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi100 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_PERMIT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_PERMIT_A") { field(DESC, "RT-OUT CL-DC Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb100",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb100") #! Field("PLC:CLTS:PP13:CLTS_RDAb100.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb100.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb100.FLNK","PPS:CLTS:3:DCBEND_PERMIT_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb100.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb100.VAL") #! Record("PPS:CLTS:3:DCBEND_PERMIT_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_PERMIT_A_calc") #! Field("PPS:CLTS:3:DCBEND_PERMIT_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_PERMIT_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_PERMIT_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb100.VAL") #! Field("PPS:CLTS:3:DCBEND_PERMIT_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_PERMIT_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_PERMIT_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_PERMIT_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_PERMIT_A_calc.OUT","PPS:CLTS:3:DCBEND_PERMIT_A.VAL") #! Record("PPS:CLTS:3:DCBEND_PERMIT_A",500,20,0,0,"PPS:CLTS:3:DCBEND_PERMIT_A") #! Field("PPS:CLTS:3:DCBEND_PERMIT_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_PERMIT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi99") { field(DESC, "Port CLTS_RDA bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 99, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:SEP_PERMIT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_PERMIT_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi99 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_PERMIT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_PERMIT_A") { field(DESC, "RT-OUT CL-Septum Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb99",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb99") #! Field("PLC:CLTS:PP13:CLTS_RDAb99.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb99.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb99.FLNK","PPS:CLTS:3:SEP_PERMIT_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb99.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb99.VAL") #! Record("PPS:CLTS:3:SEP_PERMIT_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_PERMIT_A_calc") #! Field("PPS:CLTS:3:SEP_PERMIT_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_PERMIT_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_PERMIT_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb99.VAL") #! Field("PPS:CLTS:3:SEP_PERMIT_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_PERMIT_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_PERMIT_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_PERMIT_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_PERMIT_A_calc.OUT","PPS:CLTS:3:SEP_PERMIT_A.VAL") #! Record("PPS:CLTS:3:SEP_PERMIT_A",500,20,0,0,"PPS:CLTS:3:SEP_PERMIT_A") #! Field("PPS:CLTS:3:SEP_PERMIT_A.VAL",16777215,1,"PPS:CLTS:3:SEP_PERMIT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi98") { field(DESC, "Port CLTS_RDA bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 98, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:MERGE_PERMIT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_PERMIT_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi98 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_PERMIT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_PERMIT_A") { field(DESC, "RT-OUT CL-Merge Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb98",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb98") #! Field("PLC:CLTS:PP13:CLTS_RDAb98.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb98.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb98.FLNK","PPS:CLTS:3:MERGE_PERMIT_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb98.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb98.VAL") #! Record("PPS:CLTS:3:MERGE_PERMIT_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_PERMIT_A_calc") #! Field("PPS:CLTS:3:MERGE_PERMIT_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_PERMIT_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_PERMIT_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb98.VAL") #! Field("PPS:CLTS:3:MERGE_PERMIT_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_PERMIT_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_PERMIT_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_PERMIT_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_PERMIT_A_calc.OUT","PPS:CLTS:3:MERGE_PERMIT_A.VAL") #! Record("PPS:CLTS:3:MERGE_PERMIT_A",500,20,0,0,"PPS:CLTS:3:MERGE_PERMIT_A") #! Field("PPS:CLTS:3:MERGE_PERMIT_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_PERMIT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi97") { field(DESC, "Port CLTS_RDA bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HRTBT_OUTP_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_OUTP_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi97 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_OUTP_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_OUTP_A") { field(DESC, "RT-OUT Heartbeat OUT") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb97",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb97") #! Field("PLC:CLTS:PP13:CLTS_RDAb97.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb97.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb97.FLNK","PPS:CLTS:1:HRTBT_OUTP_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb97.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb97.VAL") #! Record("PPS:CLTS:1:HRTBT_OUTP_A_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_OUTP_A_calc") #! Field("PPS:CLTS:1:HRTBT_OUTP_A_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_OUTP_A_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_OUTP_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb97.VAL") #! Field("PPS:CLTS:1:HRTBT_OUTP_A_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_OUTP_A_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_OUTP_A_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_OUTP_A_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_OUTP_A_calc.OUT","PPS:CLTS:1:HRTBT_OUTP_A.VAL") #! Record("PPS:CLTS:1:HRTBT_OUTP_A",500,20,0,0,"PPS:CLTS:1:HRTBT_OUTP_A") #! Field("PPS:CLTS:1:HRTBT_OUTP_A.VAL",16777215,1,"PPS:CLTS:1:HRTBT_OUTP_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi96") { field(DESC, "Port CLTS_RDA bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HWALRMWARN_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HWALRMWARN_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi96 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HWALRMWARN_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HWALRMWARN_A") { field(DESC, "RT-OUT ACR Hardware alarm/warning") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb96",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb96") #! Field("PLC:CLTS:PP13:CLTS_RDAb96.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb96.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb96.FLNK","PPS:CLTS:1:HWALRMWARN_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb96.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb96.VAL") #! Record("PPS:CLTS:1:HWALRMWARN_A_calc",260,18,0,1,"PPS:CLTS:1:HWALRMWARN_A_calc") #! Field("PPS:CLTS:1:HWALRMWARN_A_calc.INPA",16777215,0,"PPS:CLTS:1:HWALRMWARN_A_calc.INPA") #! Link("PPS:CLTS:1:HWALRMWARN_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb96.VAL") #! Field("PPS:CLTS:1:HWALRMWARN_A_calc.INPB",16777215,1,"PPS:CLTS:1:HWALRMWARN_A_calc.INPB") #! Field("PPS:CLTS:1:HWALRMWARN_A_calc.OUT",16777215,1,"PPS:CLTS:1:HWALRMWARN_A_calc.OUT") #! Link("PPS:CLTS:1:HWALRMWARN_A_calc.OUT","PPS:CLTS:1:HWALRMWARN_A.VAL") #! Record("PPS:CLTS:1:HWALRMWARN_A",500,20,0,0,"PPS:CLTS:1:HWALRMWARN_A") #! Field("PPS:CLTS:1:HWALRMWARN_A.VAL",16777215,1,"PPS:CLTS:1:HWALRMWARN_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi111") { field(DESC, "Port CLTS_RDA bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HRTBT_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_OK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi111 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_OK_A") { field(DESC, "RT Heartbeat OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb111",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb111") #! Field("PLC:CLTS:PP13:CLTS_RDAb111.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb111.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb111.FLNK","PPS:CLTS:1:HRTBT_OK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb111.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb111.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_A_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_OK_A_calc") #! Field("PPS:CLTS:1:HRTBT_OK_A_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_OK_A_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_OK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb111.VAL") #! Field("PPS:CLTS:1:HRTBT_OK_A_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_OK_A_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_OK_A_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_OK_A_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_OK_A_calc.OUT","PPS:CLTS:1:HRTBT_OK_A.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_A",500,20,0,0,"PPS:CLTS:1:HRTBT_OK_A") #! Field("PPS:CLTS:1:HRTBT_OK_A.VAL",16777215,1,"PPS:CLTS:1:HRTBT_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi110") { field(DESC, "Port CLTS_RDA bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 110, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:1:HRTBT_OK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_OK_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi110 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_OK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_OK_LTH_A") { field(DESC, "LAT Heartbeat OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb110",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb110") #! Field("PLC:CLTS:PP13:CLTS_RDAb110.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb110.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb110.FLNK","PPS:CLTS:1:HRTBT_OK_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb110.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb110.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_LTH_A_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_OK_LTH_A_calc") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_OK_LTH_A_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_OK_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb110.VAL") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_OK_LTH_A_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_OK_LTH_A_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_OK_LTH_A_calc.OUT","PPS:CLTS:1:HRTBT_OK_LTH_A.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_LTH_A",500,20,0,0,"PPS:CLTS:1:HRTBT_OK_LTH_A") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_A.VAL",16777215,1,"PPS:CLTS:1:HRTBT_OK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi109") { field(DESC, "Port CLTS_RDA bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:BCS_FAULT_OUT_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:BCS_FAULT_OUT_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi109 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:BCS_FAULT_OUT_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:BCS_FAULT_OUT_A") { field(DESC, "RT-OUT BCS Ok from PLC3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb109",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb109") #! Field("PLC:CLTS:PP13:CLTS_RDAb109.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb109.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb109.FLNK","PPS:CLTS:1:BCS_FAULT_OUT_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb109.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb109.VAL") #! Record("PPS:CLTS:1:BCS_FAULT_OUT_A_calc",260,18,0,1,"PPS:CLTS:1:BCS_FAULT_OUT_A_calc") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_A_calc.INPA",16777215,0,"PPS:CLTS:1:BCS_FAULT_OUT_A_calc.INPA") #! Link("PPS:CLTS:1:BCS_FAULT_OUT_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb109.VAL") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_A_calc.INPB",16777215,1,"PPS:CLTS:1:BCS_FAULT_OUT_A_calc.INPB") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_A_calc.OUT",16777215,1,"PPS:CLTS:1:BCS_FAULT_OUT_A_calc.OUT") #! Link("PPS:CLTS:1:BCS_FAULT_OUT_A_calc.OUT","PPS:CLTS:1:BCS_FAULT_OUT_A.VAL") #! Record("PPS:CLTS:1:BCS_FAULT_OUT_A",500,20,0,0,"PPS:CLTS:1:BCS_FAULT_OUT_A") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_A.VAL",16777215,1,"PPS:CLTS:1:BCS_FAULT_OUT_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi108") { field(DESC, "Port CLTS_RDA bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 108, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:KICK_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_OFF_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi108 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_OFF_LTH_A") { field(DESC, "LAT CL-Kicker OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb108",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb108") #! Field("PLC:CLTS:PP13:CLTS_RDAb108.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb108.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb108.FLNK","PPS:CLTS:3:KICK_OFF_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb108.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb108.VAL") #! Record("PPS:CLTS:3:KICK_OFF_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_OFF_LTH_A_calc") #! Field("PPS:CLTS:3:KICK_OFF_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_OFF_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_OFF_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb108.VAL") #! Field("PPS:CLTS:3:KICK_OFF_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_OFF_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_OFF_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_OFF_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_OFF_LTH_A_calc.OUT","PPS:CLTS:3:KICK_OFF_LTH_A.VAL") #! Record("PPS:CLTS:3:KICK_OFF_LTH_A",500,20,0,0,"PPS:CLTS:3:KICK_OFF_LTH_A") #! Field("PPS:CLTS:3:KICK_OFF_LTH_A.VAL",16777215,1,"PPS:CLTS:3:KICK_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi107") { field(DESC, "Port CLTS_RDA bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 107, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:DCBEND_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_OFF_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi107 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_OFF_LTH_A") { field(DESC, "LAT CL-DC OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb107",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb107") #! Field("PLC:CLTS:PP13:CLTS_RDAb107.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb107.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb107.FLNK","PPS:CLTS:3:DCBEND_OFF_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb107.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb107.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_OFF_LTH_A_calc") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb107.VAL") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_OFF_LTH_A_calc.OUT","PPS:CLTS:3:DCBEND_OFF_LTH_A.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_LTH_A",500,20,0,0,"PPS:CLTS:3:DCBEND_OFF_LTH_A") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi106") { field(DESC, "Port CLTS_RDA bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 106, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:SEP_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_OFF_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi106 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_OFF_LTH_A") { field(DESC, "LAT CL-Septum OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb106",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb106") #! Field("PLC:CLTS:PP13:CLTS_RDAb106.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb106.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb106.FLNK","PPS:CLTS:3:SEP_OFF_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb106.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb106.VAL") #! Record("PPS:CLTS:3:SEP_OFF_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_OFF_LTH_A_calc") #! Field("PPS:CLTS:3:SEP_OFF_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_OFF_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_OFF_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb106.VAL") #! Field("PPS:CLTS:3:SEP_OFF_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_OFF_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_OFF_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_OFF_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_OFF_LTH_A_calc.OUT","PPS:CLTS:3:SEP_OFF_LTH_A.VAL") #! Record("PPS:CLTS:3:SEP_OFF_LTH_A",500,20,0,0,"PPS:CLTS:3:SEP_OFF_LTH_A") #! Field("PPS:CLTS:3:SEP_OFF_LTH_A.VAL",16777215,1,"PPS:CLTS:3:SEP_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi105") { field(DESC, "Port CLTS_RDA bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 105, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:MERGE_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_OFF_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi105 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_OFF_LTH_A") { field(DESC, "LAT CL-Merge OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb105",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb105") #! Field("PLC:CLTS:PP13:CLTS_RDAb105.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb105.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb105.FLNK","PPS:CLTS:3:MERGE_OFF_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb105.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb105.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_OFF_LTH_A_calc") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_OFF_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_OFF_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb105.VAL") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_OFF_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_OFF_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_OFF_LTH_A_calc.OUT","PPS:CLTS:3:MERGE_OFF_LTH_A.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_LTH_A",500,20,0,0,"PPS:CLTS:3:MERGE_OFF_LTH_A") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi104") { field(DESC, "Port CLTS_RDA bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 104, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi104 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A") { field(DESC, "LAT HX-KickerSepMrg Summary OFF") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb104",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb104") #! Field("PLC:CLTS:PP13:CLTS_RDAb104.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb104.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb104.FLNK","PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb104.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb104.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc",260,18,0,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.INPA",16777215,0,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.INPA") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb104.VAL") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.INPB",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.INPB") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.OUT",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.OUT") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A_calc.OUT","PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A",500,20,0,0,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A.VAL",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi119") { field(DESC, "Port CLTS_RDA bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 119, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi119 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A") { field(DESC, "LAT SX-KickerSepMrg Summary OFF") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb119",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb119") #! Field("PLC:CLTS:PP13:CLTS_RDAb119.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb119.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb119.FLNK","PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb119.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb119.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc",260,18,0,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.INPA",16777215,0,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.INPA") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb119.VAL") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.INPB",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.INPB") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.OUT",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.OUT") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A_calc.OUT","PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A",500,20,0,0,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A.VAL",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi118") { field(DESC, "Port CLTS_RDA bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 118, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:CLTS:585:3:IN_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:3:IN_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi118 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:3:IN_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:3:IN_LTH_A") { field(DESC, "LAT STP-CLTS IN") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb118",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb118") #! Field("PLC:CLTS:PP13:CLTS_RDAb118.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb118.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb118.FLNK","STPR:CLTS:585:3:IN_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb118.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb118.VAL") #! Record("STPR:CLTS:585:3:IN_LTH_A_calc",260,18,0,1,"STPR:CLTS:585:3:IN_LTH_A_calc") #! Field("STPR:CLTS:585:3:IN_LTH_A_calc.INPA",16777215,0,"STPR:CLTS:585:3:IN_LTH_A_calc.INPA") #! Link("STPR:CLTS:585:3:IN_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb118.VAL") #! Field("STPR:CLTS:585:3:IN_LTH_A_calc.INPB",16777215,1,"STPR:CLTS:585:3:IN_LTH_A_calc.INPB") #! Field("STPR:CLTS:585:3:IN_LTH_A_calc.OUT",16777215,1,"STPR:CLTS:585:3:IN_LTH_A_calc.OUT") #! Link("STPR:CLTS:585:3:IN_LTH_A_calc.OUT","STPR:CLTS:585:3:IN_LTH_A.VAL") #! Record("STPR:CLTS:585:3:IN_LTH_A",500,20,0,0,"STPR:CLTS:585:3:IN_LTH_A") #! Field("STPR:CLTS:585:3:IN_LTH_A.VAL",16777215,1,"STPR:CLTS:585:3:IN_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi117") { field(DESC, "Port CLTS_RDA bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 117, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYS:3:ST34_OUT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:3:ST34_OUT_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi117 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:3:ST34_OUT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:3:ST34_OUT_LTH_A") { field(DESC, "LAT STP-34 Summary OUT") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb117",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb117") #! Field("PLC:CLTS:PP13:CLTS_RDAb117.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb117.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb117.FLNK","STPR:BSYS:3:ST34_OUT_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb117.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb117.VAL") #! Record("STPR:BSYS:3:ST34_OUT_LTH_A_calc",260,18,0,1,"STPR:BSYS:3:ST34_OUT_LTH_A_calc") #! Field("STPR:BSYS:3:ST34_OUT_LTH_A_calc.INPA",16777215,0,"STPR:BSYS:3:ST34_OUT_LTH_A_calc.INPA") #! Link("STPR:BSYS:3:ST34_OUT_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb117.VAL") #! Field("STPR:BSYS:3:ST34_OUT_LTH_A_calc.INPB",16777215,1,"STPR:BSYS:3:ST34_OUT_LTH_A_calc.INPB") #! Field("STPR:BSYS:3:ST34_OUT_LTH_A_calc.OUT",16777215,1,"STPR:BSYS:3:ST34_OUT_LTH_A_calc.OUT") #! Link("STPR:BSYS:3:ST34_OUT_LTH_A_calc.OUT","STPR:BSYS:3:ST34_OUT_LTH_A.VAL") #! Record("STPR:BSYS:3:ST34_OUT_LTH_A",500,20,0,0,"STPR:BSYS:3:ST34_OUT_LTH_A") #! Field("STPR:BSYS:3:ST34_OUT_LTH_A.VAL",16777215,1,"STPR:BSYS:3:ST34_OUT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi116") { field(DESC, "Port CLTS_RDA bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:1:ACR_ENABLE_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:ACR_ENABLE_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi116 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:ACR_ENABLE_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:ACR_ENABLE_LTH_A") { field(DESC, "LAT CLTS Admin Enable") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb116",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb116") #! Field("PLC:CLTS:PP13:CLTS_RDAb116.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb116.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb116.FLNK","PPS:CLTS:1:ACR_ENABLE_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb116.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb116.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_LTH_A_calc",260,18,0,1,"PPS:CLTS:1:ACR_ENABLE_LTH_A_calc") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.INPA") #! Link("PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb116.VAL") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.INPB") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.OUT") #! Link("PPS:CLTS:1:ACR_ENABLE_LTH_A_calc.OUT","PPS:CLTS:1:ACR_ENABLE_LTH_A.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_LTH_A",500,20,0,0,"PPS:CLTS:1:ACR_ENABLE_LTH_A") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_A.VAL",16777215,1,"PPS:CLTS:1:ACR_ENABLE_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi115") { field(DESC, "Port CLTS_RDA bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:KICK_INTLK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_INTLK_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi115 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_INTLK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_INTLK_LTH_A") { field(DESC, "LAT CL Kicker Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb115",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb115") #! Field("PLC:CLTS:PP13:CLTS_RDAb115.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb115.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb115.FLNK","PPS:CLTS:3:KICK_INTLK_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb115.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb115.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_INTLK_LTH_A_calc") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_INTLK_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_INTLK_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb115.VAL") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_INTLK_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_INTLK_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_INTLK_LTH_A_calc.OUT","PPS:CLTS:3:KICK_INTLK_LTH_A.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_LTH_A",500,20,0,0,"PPS:CLTS:3:KICK_INTLK_LTH_A") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_A.VAL",16777215,1,"PPS:CLTS:3:KICK_INTLK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi114") { field(DESC, "Port CLTS_RDA bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi114 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_INTLK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_INTLK_LTH_A") { field(DESC, "LAT CL DC Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb114",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb114") #! Field("PLC:CLTS:PP13:CLTS_RDAb114.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb114.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb114.FLNK","PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb114.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb114.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb114.VAL") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_INTLK_LTH_A_calc.OUT","PPS:CLTS:3:DCBEND_INTLK_LTH_A.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_LTH_A",500,20,0,0,"PPS:CLTS:3:DCBEND_INTLK_LTH_A") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi113") { field(DESC, "Port CLTS_RDA bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:SEP_INTLK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_INTLK_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi113 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_INTLK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_INTLK_LTH_A") { field(DESC, "LAT CL Septum Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb113",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb113") #! Field("PLC:CLTS:PP13:CLTS_RDAb113.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb113.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb113.FLNK","PPS:CLTS:3:SEP_INTLK_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb113.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb113.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_INTLK_LTH_A_calc") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_INTLK_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_INTLK_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb113.VAL") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_INTLK_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_INTLK_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_INTLK_LTH_A_calc.OUT","PPS:CLTS:3:SEP_INTLK_LTH_A.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_LTH_A",500,20,0,0,"PPS:CLTS:3:SEP_INTLK_LTH_A") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_A.VAL",16777215,1,"PPS:CLTS:3:SEP_INTLK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi112") { field(DESC, "Port CLTS_RDA bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 112, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:MERGE_INTLK_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_INTLK_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi112 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_INTLK_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_INTLK_LTH_A") { field(DESC, "LAT CL Merge Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb112",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb112") #! Field("PLC:CLTS:PP13:CLTS_RDAb112.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb112.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb112.FLNK","PPS:CLTS:3:MERGE_INTLK_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb112.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb112.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_INTLK_LTH_A_calc") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb112.VAL") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_INTLK_LTH_A_calc.OUT","PPS:CLTS:3:MERGE_INTLK_LTH_A.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_LTH_A",500,20,0,0,"PPS:CLTS:3:MERGE_INTLK_LTH_A") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_INTLK_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi127") { field(DESC, "Port CLTS_RDA bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 127, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:1:HB_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HB_FAULT_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi127 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HB_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HB_FAULT_LTH_A") { field(DESC, "LAT Heartbeat Fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb127",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb127") #! Field("PLC:CLTS:PP13:CLTS_RDAb127.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb127.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb127.FLNK","PPS:CLTS:1:HB_FAULT_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb127.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb127.VAL") #! Record("PPS:CLTS:1:HB_FAULT_LTH_A_calc",260,18,0,1,"PPS:CLTS:1:HB_FAULT_LTH_A_calc") #! Field("PPS:CLTS:1:HB_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:1:HB_FAULT_LTH_A_calc.INPA") #! Link("PPS:CLTS:1:HB_FAULT_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb127.VAL") #! Field("PPS:CLTS:1:HB_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:1:HB_FAULT_LTH_A_calc.INPB") #! Field("PPS:CLTS:1:HB_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:1:HB_FAULT_LTH_A_calc.OUT") #! Link("PPS:CLTS:1:HB_FAULT_LTH_A_calc.OUT","PPS:CLTS:1:HB_FAULT_LTH_A.VAL") #! Record("PPS:CLTS:1:HB_FAULT_LTH_A",500,20,0,0,"PPS:CLTS:1:HB_FAULT_LTH_A") #! Field("PPS:CLTS:1:HB_FAULT_LTH_A.VAL",16777215,1,"PPS:CLTS:1:HB_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi126") { field(DESC, "Port CLTS_RDA bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 126, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:KICK_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_OK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi126 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_OK_A") { field(DESC, "RT CL-Kicker status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb126",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb126") #! Field("PLC:CLTS:PP13:CLTS_RDAb126.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb126.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb126.FLNK","PPS:CLTS:3:KICK_OK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb126.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb126.VAL") #! Record("PPS:CLTS:3:KICK_OK_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_OK_A_calc") #! Field("PPS:CLTS:3:KICK_OK_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_OK_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_OK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb126.VAL") #! Field("PPS:CLTS:3:KICK_OK_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_OK_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_OK_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_OK_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_OK_A_calc.OUT","PPS:CLTS:3:KICK_OK_A.VAL") #! Record("PPS:CLTS:3:KICK_OK_A",500,20,0,0,"PPS:CLTS:3:KICK_OK_A") #! Field("PPS:CLTS:3:KICK_OK_A.VAL",16777215,1,"PPS:CLTS:3:KICK_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi125") { field(DESC, "Port CLTS_RDA bit 125") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 125, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:DCBEND_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_OK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi125 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_OK_A") { field(DESC, "RT CL-DC status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb125",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb125") #! Field("PLC:CLTS:PP13:CLTS_RDAb125.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb125.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb125.FLNK","PPS:CLTS:3:DCBEND_OK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb125.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb125.VAL") #! Record("PPS:CLTS:3:DCBEND_OK_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_OK_A_calc") #! Field("PPS:CLTS:3:DCBEND_OK_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_OK_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_OK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb125.VAL") #! Field("PPS:CLTS:3:DCBEND_OK_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_OK_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_OK_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_OK_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_OK_A_calc.OUT","PPS:CLTS:3:DCBEND_OK_A.VAL") #! Record("PPS:CLTS:3:DCBEND_OK_A",500,20,0,0,"PPS:CLTS:3:DCBEND_OK_A") #! Field("PPS:CLTS:3:DCBEND_OK_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi124") { field(DESC, "Port CLTS_RDA bit 124") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 124, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:SEP_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_OK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi124 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_OK_A") { field(DESC, "RT CL-Septum status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb124",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb124") #! Field("PLC:CLTS:PP13:CLTS_RDAb124.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb124.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb124.FLNK","PPS:CLTS:3:SEP_OK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb124.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb124.VAL") #! Record("PPS:CLTS:3:SEP_OK_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_OK_A_calc") #! Field("PPS:CLTS:3:SEP_OK_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_OK_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_OK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb124.VAL") #! Field("PPS:CLTS:3:SEP_OK_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_OK_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_OK_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_OK_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_OK_A_calc.OUT","PPS:CLTS:3:SEP_OK_A.VAL") #! Record("PPS:CLTS:3:SEP_OK_A",500,20,0,0,"PPS:CLTS:3:SEP_OK_A") #! Field("PPS:CLTS:3:SEP_OK_A.VAL",16777215,1,"PPS:CLTS:3:SEP_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi123") { field(DESC, "Port CLTS_RDA bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 123, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:MERGE_OK_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_OK_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi123 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_OK_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_OK_A") { field(DESC, "RT CL-Merge status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb123",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb123") #! Field("PLC:CLTS:PP13:CLTS_RDAb123.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb123.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb123.FLNK","PPS:CLTS:3:MERGE_OK_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb123.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb123.VAL") #! Record("PPS:CLTS:3:MERGE_OK_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_OK_A_calc") #! Field("PPS:CLTS:3:MERGE_OK_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_OK_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_OK_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb123.VAL") #! Field("PPS:CLTS:3:MERGE_OK_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_OK_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_OK_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_OK_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_OK_A_calc.OUT","PPS:CLTS:3:MERGE_OK_A.VAL") #! Record("PPS:CLTS:3:MERGE_OK_A",500,20,0,0,"PPS:CLTS:3:MERGE_OK_A") #! Field("PPS:CLTS:3:MERGE_OK_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_OK_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi122") { field(DESC, "Port CLTS_RDA bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 122, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:KICK_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_FAULT_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi122 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_FAULT_LTH_A") { field(DESC, "LAT CL-Kicker status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb122",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb122") #! Field("PLC:CLTS:PP13:CLTS_RDAb122.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb122.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb122.FLNK","PPS:CLTS:3:KICK_FAULT_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb122.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb122.VAL") #! Record("PPS:CLTS:3:KICK_FAULT_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:KICK_FAULT_LTH_A_calc") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_FAULT_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:KICK_FAULT_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb122.VAL") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_FAULT_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_FAULT_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:KICK_FAULT_LTH_A_calc.OUT","PPS:CLTS:3:KICK_FAULT_LTH_A.VAL") #! Record("PPS:CLTS:3:KICK_FAULT_LTH_A",500,20,0,0,"PPS:CLTS:3:KICK_FAULT_LTH_A") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_A.VAL",16777215,1,"PPS:CLTS:3:KICK_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi121") { field(DESC, "Port CLTS_RDA bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 121, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi121 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_FAULT_LTH_A") { field(DESC, "LAT CL-DC status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb121",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb121") #! Field("PLC:CLTS:PP13:CLTS_RDAb121.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb121.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb121.FLNK","PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb121.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb121.VAL") #! Record("PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb121.VAL") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_FAULT_LTH_A_calc.OUT","PPS:CLTS:3:DCBEND_FAULT_LTH_A.VAL") #! Record("PPS:CLTS:3:DCBEND_FAULT_LTH_A",500,20,0,0,"PPS:CLTS:3:DCBEND_FAULT_LTH_A") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_A.VAL",16777215,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi120") { field(DESC, "Port CLTS_RDA bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 120, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:SEP_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_FAULT_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi120 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_FAULT_LTH_A") { field(DESC, "LAT CL-Septum status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb120",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb120") #! Field("PLC:CLTS:PP13:CLTS_RDAb120.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb120.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb120.FLNK","PPS:CLTS:3:SEP_FAULT_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb120.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb120.VAL") #! Record("PPS:CLTS:3:SEP_FAULT_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:SEP_FAULT_LTH_A_calc") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_FAULT_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:SEP_FAULT_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb120.VAL") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_FAULT_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_FAULT_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:SEP_FAULT_LTH_A_calc.OUT","PPS:CLTS:3:SEP_FAULT_LTH_A.VAL") #! Record("PPS:CLTS:3:SEP_FAULT_LTH_A",500,20,0,0,"PPS:CLTS:3:SEP_FAULT_LTH_A") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_A.VAL",16777215,1,"PPS:CLTS:3:SEP_FAULT_LTH_A.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP13:Bi135") { field(DESC, "Port CLTS_RDA bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 135, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:MERGE_FAULT_LTH_A_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_FAULT_LTH_A_calc") { field(INPA, "PLC:CLTS:PP13:Bi135 NPP MS") field(INPB, "PLC:CLTS:PP13:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_FAULT_LTH_A PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_FAULT_LTH_A") { field(DESC, "LAT CL-Merge status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP13:CLTS_RDAb135",20,19,0,0,"PLC:CLTS:PP13:CLTS_RDAb135") #! Field("PLC:CLTS:PP13:CLTS_RDAb135.FLNK",16777215,1,"PLC:CLTS:PP13:CLTS_RDAb135.FLNK") #! Link("PLC:CLTS:PP13:CLTS_RDAb135.FLNK","PPS:CLTS:3:MERGE_FAULT_LTH_A_calc") #! Field("PLC:CLTS:PP13:CLTS_RDAb135.VAL",16777215,0,"PLC:CLTS:PP13:CLTS_RDAb135.VAL") #! Record("PPS:CLTS:3:MERGE_FAULT_LTH_A_calc",260,18,0,1,"PPS:CLTS:3:MERGE_FAULT_LTH_A_calc") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.INPA") #! Link("PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.INPA","PLC:CLTS:PP13:CLTS_RDAb135.VAL") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.INPB") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.OUT") #! Link("PPS:CLTS:3:MERGE_FAULT_LTH_A_calc.OUT","PPS:CLTS:3:MERGE_FAULT_LTH_A.VAL") #! Record("PPS:CLTS:3:MERGE_FAULT_LTH_A",500,20,0,0,"PPS:CLTS:3:MERGE_FAULT_LTH_A") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_A.VAL",16777215,1,"PPS:CLTS:3:MERGE_FAULT_LTH_A.VAL") record(bo, "PPS:CLTS:1:RESET_INTLK_A") { field(DESC, "PPS_Interlock_Reset_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:CLTS:1:PAUSEHB_A") { field(DESC, "PPS_Pause_Heartbeat_A") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:CLTS:PP13:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:CLTS:PP13:TABLE_CYCLER") { field( OUT, "PLC:CLTS:PP13:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:CLTS:PP13:SEG_CYCLER") { field( OUT, "PLC:CLTS:PP13:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:CLTS:PP13:TABLE_9_SEG_1") { field( INPA, "PLC:CLTS:PP13:REQ_TABLE CP") field( INPB, "PLC:CLTS:PP13:REQ_SEG CP") field( INPC, "PLC:CLTS:PP13:REQ_TABLE_IN CP") field( INPD, "PLC:CLTS:PP13:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:CLTS:PP13:TABLE_1_SEG_1") { field( INPA, "PLC:CLTS:PP13:REQ_TABLE CP") field( INPB, "PLC:CLTS:PP13:REQ_SEG CP") field( INPC, "PLC:CLTS:PP13:REQ_TABLE_IN CP") field( INPD, "PLC:CLTS:PP13:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:CLTS:PP13:REQ_TABLE_OUT") { field(OUTA, "PLC:CLTS:PP13:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:CLTS:PP13:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:CLTS:PP13:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:CLTS:PP13:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:CLTS:PP13:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:CLTS:PP13:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:CLTS:PP13:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:CLTS:PP13:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:CLTS:PP13:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT0 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT1 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT2 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT3 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT4 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT5 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT6 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP13:TABLE_BIT7 MS") field(INPC, "PLC:CLTS:PP13:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:CLTS:PP13:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:CLTS:PP13:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:CLTS:PP13:TABLE_BIT0 CP MS") field(INPB, "PLC:CLTS:PP13:TABLE_BIT1 CP MS") field(INPC, "PLC:CLTS:PP13:TABLE_BIT2 CP MS") field(INPD, "PLC:CLTS:PP13:TABLE_BIT3 CP MS") field(INPE, "PLC:CLTS:PP13:TABLE_BIT4 CP MS") field(INPF, "PLC:CLTS:PP13:TABLE_BIT5 CP MS") field(INPG, "PLC:CLTS:PP13:TABLE_BIT6 CP MS") field(INPH, "PLC:CLTS:PP13:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:CLTS:PP13:REQ_TABLE PP MS") #field(SDIS, "PLC:CLTS:PP13:REQ_TABLE_OUT.PACT") } record(longout, "PLC:CLTS:PP13:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:CLTS:PP13:REQ_SEG_OUT") { field(OUTA, "PLC:CLTS:PP13:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:CLTS:PP13:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:CLTS:PP13:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:CLTS:PP13:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:CLTS:PP13:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:CLTS:PP13:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:CLTS:PP13:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:CLTS:PP13:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:CLTS:PP13:REQ_SEG_IN.PACT") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT0 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT1 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT1 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT2 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT2 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT3 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT3 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT4 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT4 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT5 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT5 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT6 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT6 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:CLTS:PP13:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP13:SEG_BIT7 MS") field(INPC, "PLC:CLTS:PP13:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:CLTS:PP13:REQ_SEG_BIT7 PP") } record(calcout, "PLC:CLTS:PP13:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:CLTS:PP13:SEG_BIT0 CP MS") field(INPB, "PLC:CLTS:PP13:SEG_BIT1 CP MS") field(INPC, "PLC:CLTS:PP13:SEG_BIT2 CP MS") field(INPD, "PLC:CLTS:PP13:SEG_BIT3 CP MS") field(INPE, "PLC:CLTS:PP13:SEG_BIT4 CP MS") field(INPF, "PLC:CLTS:PP13:SEG_BIT5 CP MS") field(INPG, "PLC:CLTS:PP13:SEG_BIT6 CP MS") field(INPH, "PLC:CLTS:PP13:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:CLTS:PP13:REQ_SEG PP MS") field(SDIS, "PLC:CLTS:PP13:REQ_SEG_OUT.PACT") } record(bi, "PLC:CLTS:PP13:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP13:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP13:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTA, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:CLTS:PP13:w0") { field(DESC, "CLTS CHAINA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:w1") { field(DESC, "CLTS CHAINA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 2, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:CLTS:PP13:CHECKSUM_SDIS") { field(INPA, "PLC:CLTS:PP13:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:CLTS:PP13:w3") { field(DESC, "CLTS CHAINA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 3, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP13:CHECKSUM_SAFE_calc") { field(INPA, "PLC:CLTS:PP13:w3 PP MS") field(INPB, "PLC:CLTS:PP13:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP13:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:CLTS:PP13:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP13:w4") { field(DESC, "CLTS CHAINA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 4, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP13:PROJ_CHECKSUM_calc") { field(INPA, "PLC:CLTS:PP13:w4 NPP MS") field(INPB, "PLC:CLTS:PP13:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP13:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP13:w5") { field(DESC, "CLTS CHAINA Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 5, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP13:DAY_MONTH_calc") { field(INPA, "PLC:CLTS:PP13:w5 NPP MS") field(INPB, "PLC:CLTS:PP13:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP13:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:CLTS:PP13:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:CLTS:PP13:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:CLTS:PP13:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:CLTS:PP13:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP13:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 6, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP13:PROJ_YEAR_calc") { field(INPA, "PLC:CLTS:PP13:w6 NPP MS") field(INPB, "PLC:CLTS:PP13:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP13:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP13:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 7, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP13:OP_HRS_MSB_calc") { field(INPA, "PLC:CLTS:PP13:w7 NPP MS") field(INPB, "PLC:CLTS:PP13:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP13:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDA, 8, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP13:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP13:OP_HRS_LSB_calc") { field(INPA, "PLC:CLTS:PP13:w8 NPP MS") field(INPB, "PLC:CLTS:PP13:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP13:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP13:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:CLTS:PP13:OP_HOURS") { field(INPA, "PLC:CLTS:PP13:OP_HRS_MSB CP MS") field(INPB, "PLC:CLTS:PP13:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:CLTS:PP13:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:CLTS:PP13:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:CLTS:PP13:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(CLTS_RDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:CLTS:PP13:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:CLTS:PP13:RDHist.PROC") } record(waveform,"PLC:CLTS:PP13:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_RDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP13:RDHistTimeAxis.PROC") } record(waveform,"PLC:CLTS:PP13:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_RDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP13:RDReadOK.PROC") } record(longout,"PLC:CLTS:PP13:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(CLTS_RDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:CLTS:PP13:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDA 0)READ_OK") field(FLNK,"PLC:CLTS:PP13:RDWriteOK.PROC") } record(longin,"PLC:CLTS:PP13:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDA 0)WRITE_OK") field(FLNK,"PLC:CLTS:PP13:RDIOErrors.PROC") } record(longin,"PLC:CLTS:PP13:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDA 0)IO_ERRORS") field(FLNK,"PLC:CLTS:PP13:RDLastIOTime.PROC") } record(longin,"PLC:CLTS:PP13:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDA 0)LAST_IO_TIME") field(FLNK,"PLC:CLTS:PP13:RDMaxIOTime.PROC") } record(longin,"PLC:CLTS:PP13:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:CLTS:PP13:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(CLTS_WRTA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:CLTS:PP13:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:CLTS:PP13:WRTHist.PROC") } record(waveform,"PLC:CLTS:PP13:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WRTA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP13:WRTHistTimeAxis.PROC") } record(waveform,"PLC:CLTS:PP13:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WRTA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP13:WRTReadOK.PROC") } record(longout,"PLC:CLTS:PP13:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(CLTS_WRTA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:CLTS:PP13:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTA 0)READ_OK") field(FLNK,"PLC:CLTS:PP13:WRTWriteOK.PROC") } record(longin,"PLC:CLTS:PP13:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTA 0)WRITE_OK") field(FLNK,"PLC:CLTS:PP13:WRTIOErrors.PROC") } record(longin,"PLC:CLTS:PP13:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTA 0)IO_ERRORS") field(FLNK,"PLC:CLTS:PP13:WRTLastIOTime.PROC") } record(longin,"PLC:CLTS:PP13:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTA 0)LAST_IO_TIME") field(FLNK,"PLC:CLTS:PP13:WRTMaxIOTime.PROC") } record(longin,"PLC:CLTS:PP13:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTA 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:CLTS:PP13:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(CLTS_WDA 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:CLTS:PP13:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:CLTS:PP13:WDHist.PROC") } record(waveform,"PLC:CLTS:PP13:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WDA 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP13:WDHistTimeAxis.PROC") } record(waveform,"PLC:CLTS:PP13:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WDA 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP13:WDReadOK.PROC") } record(longout,"PLC:CLTS:PP13:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(CLTS_WDA 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:CLTS:PP13:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDA 0)READ_OK") field(FLNK,"PLC:CLTS:PP13:WDWriteOK.PROC") } record(longin,"PLC:CLTS:PP13:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDA 0)WRITE_OK") field(FLNK,"PLC:CLTS:PP13:WDIOErrors.PROC") } record(longin,"PLC:CLTS:PP13:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDA 0)IO_ERRORS") field(FLNK,"PLC:CLTS:PP13:WDLastIOTime.PROC") } record(longin,"PLC:CLTS:PP13:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDA 0)LAST_IO_TIME") field(FLNK,"PLC:CLTS:PP13:WDMaxIOTime.PROC") } record(longin,"PLC:CLTS:PP13:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDA 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi7") { field(DESC, "Port CLTS_RDB bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 7, 1, 1)") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(FLNK, "PPS:CLTS:1:HW_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HW_ENABLE_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi7 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HW_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HW_ENABLE_B") { field(DESC, "RT-IN HW Enable") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb7",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb7") #! Field("PLC:CLTS:PP14:CLTS_RDBb7.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb7.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb7.FLNK","PPS:CLTS:1:HW_ENABLE_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb7.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb7.VAL") #! Record("PPS:CLTS:1:HW_ENABLE_B_calc",260,18,0,1,"PPS:CLTS:1:HW_ENABLE_B_calc") #! Field("PPS:CLTS:1:HW_ENABLE_B_calc.INPA",16777215,0,"PPS:CLTS:1:HW_ENABLE_B_calc.INPA") #! Link("PPS:CLTS:1:HW_ENABLE_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb7.VAL") #! Field("PPS:CLTS:1:HW_ENABLE_B_calc.INPB",16777215,1,"PPS:CLTS:1:HW_ENABLE_B_calc.INPB") #! Field("PPS:CLTS:1:HW_ENABLE_B_calc.OUT",16777215,1,"PPS:CLTS:1:HW_ENABLE_B_calc.OUT") #! Link("PPS:CLTS:1:HW_ENABLE_B_calc.OUT","PPS:CLTS:1:HW_ENABLE_B.VAL") #! Record("PPS:CLTS:1:HW_ENABLE_B",500,20,0,0,"PPS:CLTS:1:HW_ENABLE_B") #! Field("PPS:CLTS:1:HW_ENABLE_B.VAL",16777215,1,"PPS:CLTS:1:HW_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi6") { field(DESC, "Port CLTS_RDB bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 6, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:KICK_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_OFF_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi6 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_OFF_B") { field(DESC, "RT-IN CL-Kicker OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb6",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb6") #! Field("PLC:CLTS:PP14:CLTS_RDBb6.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb6.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb6.FLNK","PPS:CLTS:3:KICK_OFF_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb6.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb6.VAL") #! Record("PPS:CLTS:3:KICK_OFF_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_OFF_B_calc") #! Field("PPS:CLTS:3:KICK_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_OFF_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_OFF_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb6.VAL") #! Field("PPS:CLTS:3:KICK_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_OFF_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_OFF_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_OFF_B_calc.OUT","PPS:CLTS:3:KICK_OFF_B.VAL") #! Record("PPS:CLTS:3:KICK_OFF_B",500,20,0,0,"PPS:CLTS:3:KICK_OFF_B") #! Field("PPS:CLTS:3:KICK_OFF_B.VAL",16777215,1,"PPS:CLTS:3:KICK_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi5") { field(DESC, "Port CLTS_RDB bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 5, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:DCBEND_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_OFF_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi5 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_OFF_B") { field(DESC, "RT-IN CL-DC OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb5",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb5") #! Field("PLC:CLTS:PP14:CLTS_RDBb5.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb5.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb5.FLNK","PPS:CLTS:3:DCBEND_OFF_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb5.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb5.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_OFF_B_calc") #! Field("PPS:CLTS:3:DCBEND_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_OFF_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_OFF_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb5.VAL") #! Field("PPS:CLTS:3:DCBEND_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_OFF_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_OFF_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_OFF_B_calc.OUT","PPS:CLTS:3:DCBEND_OFF_B.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_B",500,20,0,0,"PPS:CLTS:3:DCBEND_OFF_B") #! Field("PPS:CLTS:3:DCBEND_OFF_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi4") { field(DESC, "Port CLTS_RDB bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 4, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:SEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_OFF_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi4 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_OFF_B") { field(DESC, "RT-IN CL-Septum OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb4",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb4") #! Field("PLC:CLTS:PP14:CLTS_RDBb4.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb4.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb4.FLNK","PPS:CLTS:3:SEP_OFF_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb4.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb4.VAL") #! Record("PPS:CLTS:3:SEP_OFF_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_OFF_B_calc") #! Field("PPS:CLTS:3:SEP_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_OFF_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_OFF_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb4.VAL") #! Field("PPS:CLTS:3:SEP_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_OFF_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_OFF_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_OFF_B_calc.OUT","PPS:CLTS:3:SEP_OFF_B.VAL") #! Record("PPS:CLTS:3:SEP_OFF_B",500,20,0,0,"PPS:CLTS:3:SEP_OFF_B") #! Field("PPS:CLTS:3:SEP_OFF_B.VAL",16777215,1,"PPS:CLTS:3:SEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi3") { field(DESC, "Port CLTS_RDB bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 3, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:CLTS:3:MERGE_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_OFF_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi3 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_OFF_B") { field(DESC, "RT-IN CL-Merge OFF status") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb3",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb3") #! Field("PLC:CLTS:PP14:CLTS_RDBb3.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb3.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb3.FLNK","PPS:CLTS:3:MERGE_OFF_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb3.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb3.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_OFF_B_calc") #! Field("PPS:CLTS:3:MERGE_OFF_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_OFF_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_OFF_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb3.VAL") #! Field("PPS:CLTS:3:MERGE_OFF_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_OFF_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_OFF_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_OFF_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_OFF_B_calc.OUT","PPS:CLTS:3:MERGE_OFF_B.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_B",500,20,0,0,"PPS:CLTS:3:MERGE_OFF_B") #! Field("PPS:CLTS:3:MERGE_OFF_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi2") { field(DESC, "Port CLTS_RDB bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 2, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI28:3:HXR:KICKSEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:3:HXR:KICKSEP_OFF_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi2 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:3:HXR:KICKSEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:3:HXR:KICKSEP_OFF_B") { field(DESC, "RT-IN HX-KickerSepMrg Summary OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb2",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb2") #! Field("PLC:CLTS:PP14:CLTS_RDBb2.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb2.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb2.FLNK","PPS:LI28:3:HXR:KICKSEP_OFF_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb2.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb2.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_B_calc",260,18,0,1,"PPS:LI28:3:HXR:KICKSEP_OFF_B_calc") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.INPA",16777215,0,"PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.INPA") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb2.VAL") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.INPB",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.INPB") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.OUT",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.OUT") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_B_calc.OUT","PPS:LI28:3:HXR:KICKSEP_OFF_B.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_B",500,20,0,0,"PPS:LI28:3:HXR:KICKSEP_OFF_B") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_B.VAL",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi1") { field(DESC, "Port CLTS_RDB bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 1, 1, 1)") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(FLNK, "PPS:LI30:3:SXR:KICKSEP_OFF_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:3:SXR:KICKSEP_OFF_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi1 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:3:SXR:KICKSEP_OFF_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:3:SXR:KICKSEP_OFF_B") { field(DESC, "RT-IN SX-KickerSepMrg Summary OFF") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb1",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb1") #! Field("PLC:CLTS:PP14:CLTS_RDBb1.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb1.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb1.FLNK","PPS:LI30:3:SXR:KICKSEP_OFF_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb1.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb1.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_B_calc",260,18,0,1,"PPS:LI30:3:SXR:KICKSEP_OFF_B_calc") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.INPA",16777215,0,"PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.INPA") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb1.VAL") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.INPB",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.INPB") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.OUT",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.OUT") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_B_calc.OUT","PPS:LI30:3:SXR:KICKSEP_OFF_B.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_B",500,20,0,0,"PPS:LI30:3:SXR:KICKSEP_OFF_B") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_B.VAL",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi0") { field(DESC, "Port CLTS_RDB bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 0, 1, 1)") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(FLNK, "STPR:CLTS:585:3:IN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:3:IN_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi0 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:3:IN_B PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:3:IN_B") { field(DESC, "RT-IN STP-CLTS IN") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb0",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb0") #! Field("PLC:CLTS:PP14:CLTS_RDBb0.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb0.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb0.FLNK","STPR:CLTS:585:3:IN_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb0.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb0.VAL") #! Record("STPR:CLTS:585:3:IN_B_calc",260,18,0,1,"STPR:CLTS:585:3:IN_B_calc") #! Field("STPR:CLTS:585:3:IN_B_calc.INPA",16777215,0,"STPR:CLTS:585:3:IN_B_calc.INPA") #! Link("STPR:CLTS:585:3:IN_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb0.VAL") #! Field("STPR:CLTS:585:3:IN_B_calc.INPB",16777215,1,"STPR:CLTS:585:3:IN_B_calc.INPB") #! Field("STPR:CLTS:585:3:IN_B_calc.OUT",16777215,1,"STPR:CLTS:585:3:IN_B_calc.OUT") #! Link("STPR:CLTS:585:3:IN_B_calc.OUT","STPR:CLTS:585:3:IN_B.VAL") #! Record("STPR:CLTS:585:3:IN_B",500,20,0,0,"STPR:CLTS:585:3:IN_B") #! Field("STPR:CLTS:585:3:IN_B.VAL",16777215,1,"STPR:CLTS:585:3:IN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi15") { field(DESC, "Port CLTS_RDB bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "STPR:BSYS:3:ST34_OUT_SUM_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:3:ST34_OUT_SUM_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi15 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:3:ST34_OUT_SUM_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:3:ST34_OUT_SUM_B") { field(DESC, "RT-IN STP-34 Summary OUT") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb15",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb15") #! Field("PLC:CLTS:PP14:CLTS_RDBb15.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb15.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb15.FLNK","STPR:BSYS:3:ST34_OUT_SUM_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb15.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb15.VAL") #! Record("STPR:BSYS:3:ST34_OUT_SUM_B_calc",260,18,0,1,"STPR:BSYS:3:ST34_OUT_SUM_B_calc") #! Field("STPR:BSYS:3:ST34_OUT_SUM_B_calc.INPA",16777215,0,"STPR:BSYS:3:ST34_OUT_SUM_B_calc.INPA") #! Link("STPR:BSYS:3:ST34_OUT_SUM_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb15.VAL") #! Field("STPR:BSYS:3:ST34_OUT_SUM_B_calc.INPB",16777215,1,"STPR:BSYS:3:ST34_OUT_SUM_B_calc.INPB") #! Field("STPR:BSYS:3:ST34_OUT_SUM_B_calc.OUT",16777215,1,"STPR:BSYS:3:ST34_OUT_SUM_B_calc.OUT") #! Link("STPR:BSYS:3:ST34_OUT_SUM_B_calc.OUT","STPR:BSYS:3:ST34_OUT_SUM_B.VAL") #! Record("STPR:BSYS:3:ST34_OUT_SUM_B",500,20,0,0,"STPR:BSYS:3:ST34_OUT_SUM_B") #! Field("STPR:BSYS:3:ST34_OUT_SUM_B.VAL",16777215,1,"STPR:BSYS:3:ST34_OUT_SUM_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi14") { field(DESC, "Port CLTS_RDB bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HRTBT_INP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_INP_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi14 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_INP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_INP_B") { field(DESC, "RT-IN Heartbeat IN from opposite chain") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb14",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb14") #! Field("PLC:CLTS:PP14:CLTS_RDBb14.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb14.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb14.FLNK","PPS:CLTS:1:HRTBT_INP_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb14.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb14.VAL") #! Record("PPS:CLTS:1:HRTBT_INP_B_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_INP_B_calc") #! Field("PPS:CLTS:1:HRTBT_INP_B_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_INP_B_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_INP_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb14.VAL") #! Field("PPS:CLTS:1:HRTBT_INP_B_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_INP_B_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_INP_B_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_INP_B_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_INP_B_calc.OUT","PPS:CLTS:1:HRTBT_INP_B.VAL") #! Record("PPS:CLTS:1:HRTBT_INP_B",500,20,0,0,"PPS:CLTS:1:HRTBT_INP_B") #! Field("PPS:CLTS:1:HRTBT_INP_B.VAL",16777215,1,"PPS:CLTS:1:HRTBT_INP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi13") { field(DESC, "Port CLTS_RDB bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 13, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:ACR_ENABLE_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:ACR_ENABLE_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi13 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:ACR_ENABLE_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:ACR_ENABLE_B") { field(DESC, "RT-IN CLTS Admin Enable (jumpered)") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb13",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb13") #! Field("PLC:CLTS:PP14:CLTS_RDBb13.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb13.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb13.FLNK","PPS:CLTS:1:ACR_ENABLE_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb13.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb13.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_B_calc",260,18,0,1,"PPS:CLTS:1:ACR_ENABLE_B_calc") #! Field("PPS:CLTS:1:ACR_ENABLE_B_calc.INPA",16777215,0,"PPS:CLTS:1:ACR_ENABLE_B_calc.INPA") #! Link("PPS:CLTS:1:ACR_ENABLE_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb13.VAL") #! Field("PPS:CLTS:1:ACR_ENABLE_B_calc.INPB",16777215,1,"PPS:CLTS:1:ACR_ENABLE_B_calc.INPB") #! Field("PPS:CLTS:1:ACR_ENABLE_B_calc.OUT",16777215,1,"PPS:CLTS:1:ACR_ENABLE_B_calc.OUT") #! Link("PPS:CLTS:1:ACR_ENABLE_B_calc.OUT","PPS:CLTS:1:ACR_ENABLE_B.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_B",500,20,0,0,"PPS:CLTS:1:ACR_ENABLE_B") #! Field("PPS:CLTS:1:ACR_ENABLE_B.VAL",16777215,1,"PPS:CLTS:1:ACR_ENABLE_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi12") { field(DESC, "Port CLTS_RDB bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HW_RESET_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HW_RESET_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi12 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HW_RESET_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HW_RESET_B") { field(DESC, "RT-IN HW Reset") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb12",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb12") #! Field("PLC:CLTS:PP14:CLTS_RDBb12.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb12.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb12.FLNK","PPS:CLTS:1:HW_RESET_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb12.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb12.VAL") #! Record("PPS:CLTS:1:HW_RESET_B_calc",260,18,0,1,"PPS:CLTS:1:HW_RESET_B_calc") #! Field("PPS:CLTS:1:HW_RESET_B_calc.INPA",16777215,0,"PPS:CLTS:1:HW_RESET_B_calc.INPA") #! Link("PPS:CLTS:1:HW_RESET_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb12.VAL") #! Field("PPS:CLTS:1:HW_RESET_B_calc.INPB",16777215,1,"PPS:CLTS:1:HW_RESET_B_calc.INPB") #! Field("PPS:CLTS:1:HW_RESET_B_calc.OUT",16777215,1,"PPS:CLTS:1:HW_RESET_B_calc.OUT") #! Link("PPS:CLTS:1:HW_RESET_B_calc.OUT","PPS:CLTS:1:HW_RESET_B.VAL") #! Record("PPS:CLTS:1:HW_RESET_B",500,20,0,0,"PPS:CLTS:1:HW_RESET_B") #! Field("PPS:CLTS:1:HW_RESET_B.VAL",16777215,1,"PPS:CLTS:1:HW_RESET_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi11") { field(DESC, "Port CLTS_RDB bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 11, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:KICK_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_INTLK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi11 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_INTLK_B") { field(DESC, "RT-IN CL Kicker Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb11",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb11") #! Field("PLC:CLTS:PP14:CLTS_RDBb11.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb11.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb11.FLNK","PPS:CLTS:3:KICK_INTLK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb11.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb11.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_INTLK_B_calc") #! Field("PPS:CLTS:3:KICK_INTLK_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_INTLK_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_INTLK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb11.VAL") #! Field("PPS:CLTS:3:KICK_INTLK_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_INTLK_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_INTLK_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_INTLK_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_INTLK_B_calc.OUT","PPS:CLTS:3:KICK_INTLK_B.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_B",500,20,0,0,"PPS:CLTS:3:KICK_INTLK_B") #! Field("PPS:CLTS:3:KICK_INTLK_B.VAL",16777215,1,"PPS:CLTS:3:KICK_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi10") { field(DESC, "Port CLTS_RDB bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 10, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:DCBEND_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_INTLK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi10 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_INTLK_B") { field(DESC, "RT-IN CL DC Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb10",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb10") #! Field("PLC:CLTS:PP14:CLTS_RDBb10.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb10.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb10.FLNK","PPS:CLTS:3:DCBEND_INTLK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb10.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb10.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_INTLK_B_calc") #! Field("PPS:CLTS:3:DCBEND_INTLK_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_INTLK_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_INTLK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb10.VAL") #! Field("PPS:CLTS:3:DCBEND_INTLK_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_INTLK_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_INTLK_B_calc.OUT","PPS:CLTS:3:DCBEND_INTLK_B.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_B",500,20,0,0,"PPS:CLTS:3:DCBEND_INTLK_B") #! Field("PPS:CLTS:3:DCBEND_INTLK_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi9") { field(DESC, "Port CLTS_RDB bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 9, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:SEP_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_INTLK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi9 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_INTLK_B") { field(DESC, "RT-IN CL Septum Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb9",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb9") #! Field("PLC:CLTS:PP14:CLTS_RDBb9.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb9.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb9.FLNK","PPS:CLTS:3:SEP_INTLK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb9.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb9.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_INTLK_B_calc") #! Field("PPS:CLTS:3:SEP_INTLK_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_INTLK_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_INTLK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb9.VAL") #! Field("PPS:CLTS:3:SEP_INTLK_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_INTLK_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_INTLK_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_INTLK_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_INTLK_B_calc.OUT","PPS:CLTS:3:SEP_INTLK_B.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_B",500,20,0,0,"PPS:CLTS:3:SEP_INTLK_B") #! Field("PPS:CLTS:3:SEP_INTLK_B.VAL",16777215,1,"PPS:CLTS:3:SEP_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi8") { field(DESC, "Port CLTS_RDB bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 8, 1, 1)") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(FLNK, "PPS:CLTS:3:MERGE_INTLK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_INTLK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi8 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_INTLK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_INTLK_B") { field(DESC, "RT-IN CL Merge Interlock") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb8",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb8") #! Field("PLC:CLTS:PP14:CLTS_RDBb8.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb8.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb8.FLNK","PPS:CLTS:3:MERGE_INTLK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb8.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb8.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_INTLK_B_calc") #! Field("PPS:CLTS:3:MERGE_INTLK_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_INTLK_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_INTLK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb8.VAL") #! Field("PPS:CLTS:3:MERGE_INTLK_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_INTLK_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_INTLK_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_INTLK_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_INTLK_B_calc.OUT","PPS:CLTS:3:MERGE_INTLK_B.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_B",500,20,0,0,"PPS:CLTS:3:MERGE_INTLK_B") #! Field("PPS:CLTS:3:MERGE_INTLK_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_INTLK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi89") { field(DESC, "Port CLTS_RDB bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 89, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:KICK_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_ON_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi89 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_ON_B") { field(DESC, "RT-OUT CL-Kicker ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb89",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb89") #! Field("PLC:CLTS:PP14:CLTS_RDBb89.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb89.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb89.FLNK","PPS:CLTS:3:KICK_ON_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb89.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb89.VAL") #! Record("PPS:CLTS:3:KICK_ON_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_ON_B_calc") #! Field("PPS:CLTS:3:KICK_ON_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_ON_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_ON_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb89.VAL") #! Field("PPS:CLTS:3:KICK_ON_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_ON_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_ON_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_ON_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_ON_B_calc.OUT","PPS:CLTS:3:KICK_ON_B.VAL") #! Record("PPS:CLTS:3:KICK_ON_B",500,20,0,0,"PPS:CLTS:3:KICK_ON_B") #! Field("PPS:CLTS:3:KICK_ON_B.VAL",16777215,1,"PPS:CLTS:3:KICK_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi88") { field(DESC, "Port CLTS_RDB bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 88, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:DCBEND_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_ON_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi88 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_ON_B") { field(DESC, "RT-OUT CL-DC ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb88",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb88") #! Field("PLC:CLTS:PP14:CLTS_RDBb88.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb88.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb88.FLNK","PPS:CLTS:3:DCBEND_ON_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb88.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb88.VAL") #! Record("PPS:CLTS:3:DCBEND_ON_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_ON_B_calc") #! Field("PPS:CLTS:3:DCBEND_ON_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_ON_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_ON_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb88.VAL") #! Field("PPS:CLTS:3:DCBEND_ON_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_ON_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_ON_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_ON_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_ON_B_calc.OUT","PPS:CLTS:3:DCBEND_ON_B.VAL") #! Record("PPS:CLTS:3:DCBEND_ON_B",500,20,0,0,"PPS:CLTS:3:DCBEND_ON_B") #! Field("PPS:CLTS:3:DCBEND_ON_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi103") { field(DESC, "Port CLTS_RDB bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 103, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:SEP_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_ON_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi103 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_ON_B") { field(DESC, "RT-OUT CL-Septum ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb103",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb103") #! Field("PLC:CLTS:PP14:CLTS_RDBb103.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb103.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb103.FLNK","PPS:CLTS:3:SEP_ON_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb103.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb103.VAL") #! Record("PPS:CLTS:3:SEP_ON_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_ON_B_calc") #! Field("PPS:CLTS:3:SEP_ON_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_ON_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_ON_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb103.VAL") #! Field("PPS:CLTS:3:SEP_ON_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_ON_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_ON_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_ON_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_ON_B_calc.OUT","PPS:CLTS:3:SEP_ON_B.VAL") #! Record("PPS:CLTS:3:SEP_ON_B",500,20,0,0,"PPS:CLTS:3:SEP_ON_B") #! Field("PPS:CLTS:3:SEP_ON_B.VAL",16777215,1,"PPS:CLTS:3:SEP_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi102") { field(DESC, "Port CLTS_RDB bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 102, 1, 1)") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(FLNK, "PPS:CLTS:3:MERGE_ON_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_ON_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi102 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_ON_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_ON_B") { field(DESC, "RT-OUT CL-Merge ON status") field(ZNAM, "NOT_ON") field(ONAM, "ON") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb102",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb102") #! Field("PLC:CLTS:PP14:CLTS_RDBb102.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb102.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb102.FLNK","PPS:CLTS:3:MERGE_ON_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb102.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb102.VAL") #! Record("PPS:CLTS:3:MERGE_ON_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_ON_B_calc") #! Field("PPS:CLTS:3:MERGE_ON_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_ON_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_ON_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb102.VAL") #! Field("PPS:CLTS:3:MERGE_ON_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_ON_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_ON_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_ON_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_ON_B_calc.OUT","PPS:CLTS:3:MERGE_ON_B.VAL") #! Record("PPS:CLTS:3:MERGE_ON_B",500,20,0,0,"PPS:CLTS:3:MERGE_ON_B") #! Field("PPS:CLTS:3:MERGE_ON_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_ON_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi101") { field(DESC, "Port CLTS_RDB bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 101, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:KICK_PERMIT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_PERMIT_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi101 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_PERMIT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_PERMIT_B") { field(DESC, "RT-OUT CL-Kicker Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb101",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb101") #! Field("PLC:CLTS:PP14:CLTS_RDBb101.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb101.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb101.FLNK","PPS:CLTS:3:KICK_PERMIT_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb101.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb101.VAL") #! Record("PPS:CLTS:3:KICK_PERMIT_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_PERMIT_B_calc") #! Field("PPS:CLTS:3:KICK_PERMIT_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_PERMIT_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_PERMIT_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb101.VAL") #! Field("PPS:CLTS:3:KICK_PERMIT_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_PERMIT_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_PERMIT_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_PERMIT_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_PERMIT_B_calc.OUT","PPS:CLTS:3:KICK_PERMIT_B.VAL") #! Record("PPS:CLTS:3:KICK_PERMIT_B",500,20,0,0,"PPS:CLTS:3:KICK_PERMIT_B") #! Field("PPS:CLTS:3:KICK_PERMIT_B.VAL",16777215,1,"PPS:CLTS:3:KICK_PERMIT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi100") { field(DESC, "Port CLTS_RDB bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 100, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:DCBEND_PERMIT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_PERMIT_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi100 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_PERMIT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_PERMIT_B") { field(DESC, "RT-OUT CL-DC Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb100",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb100") #! Field("PLC:CLTS:PP14:CLTS_RDBb100.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb100.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb100.FLNK","PPS:CLTS:3:DCBEND_PERMIT_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb100.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb100.VAL") #! Record("PPS:CLTS:3:DCBEND_PERMIT_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_PERMIT_B_calc") #! Field("PPS:CLTS:3:DCBEND_PERMIT_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_PERMIT_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_PERMIT_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb100.VAL") #! Field("PPS:CLTS:3:DCBEND_PERMIT_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_PERMIT_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_PERMIT_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_PERMIT_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_PERMIT_B_calc.OUT","PPS:CLTS:3:DCBEND_PERMIT_B.VAL") #! Record("PPS:CLTS:3:DCBEND_PERMIT_B",500,20,0,0,"PPS:CLTS:3:DCBEND_PERMIT_B") #! Field("PPS:CLTS:3:DCBEND_PERMIT_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_PERMIT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi99") { field(DESC, "Port CLTS_RDB bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 99, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:SEP_PERMIT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_PERMIT_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi99 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_PERMIT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_PERMIT_B") { field(DESC, "RT-OUT CL-Septum Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb99",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb99") #! Field("PLC:CLTS:PP14:CLTS_RDBb99.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb99.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb99.FLNK","PPS:CLTS:3:SEP_PERMIT_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb99.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb99.VAL") #! Record("PPS:CLTS:3:SEP_PERMIT_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_PERMIT_B_calc") #! Field("PPS:CLTS:3:SEP_PERMIT_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_PERMIT_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_PERMIT_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb99.VAL") #! Field("PPS:CLTS:3:SEP_PERMIT_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_PERMIT_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_PERMIT_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_PERMIT_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_PERMIT_B_calc.OUT","PPS:CLTS:3:SEP_PERMIT_B.VAL") #! Record("PPS:CLTS:3:SEP_PERMIT_B",500,20,0,0,"PPS:CLTS:3:SEP_PERMIT_B") #! Field("PPS:CLTS:3:SEP_PERMIT_B.VAL",16777215,1,"PPS:CLTS:3:SEP_PERMIT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi98") { field(DESC, "Port CLTS_RDB bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 98, 1, 1)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(FLNK, "PPS:CLTS:3:MERGE_PERMIT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_PERMIT_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi98 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_PERMIT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_PERMIT_B") { field(DESC, "RT-OUT CL-Merge Pwr Sply Pmt (Out)") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb98",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb98") #! Field("PLC:CLTS:PP14:CLTS_RDBb98.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb98.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb98.FLNK","PPS:CLTS:3:MERGE_PERMIT_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb98.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb98.VAL") #! Record("PPS:CLTS:3:MERGE_PERMIT_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_PERMIT_B_calc") #! Field("PPS:CLTS:3:MERGE_PERMIT_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_PERMIT_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_PERMIT_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb98.VAL") #! Field("PPS:CLTS:3:MERGE_PERMIT_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_PERMIT_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_PERMIT_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_PERMIT_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_PERMIT_B_calc.OUT","PPS:CLTS:3:MERGE_PERMIT_B.VAL") #! Record("PPS:CLTS:3:MERGE_PERMIT_B",500,20,0,0,"PPS:CLTS:3:MERGE_PERMIT_B") #! Field("PPS:CLTS:3:MERGE_PERMIT_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_PERMIT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi97") { field(DESC, "Port CLTS_RDB bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HRTBT_OUTP_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_OUTP_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi97 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_OUTP_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_OUTP_B") { field(DESC, "RT-OUT Heartbeat OUT") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb97",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb97") #! Field("PLC:CLTS:PP14:CLTS_RDBb97.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb97.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb97.FLNK","PPS:CLTS:1:HRTBT_OUTP_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb97.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb97.VAL") #! Record("PPS:CLTS:1:HRTBT_OUTP_B_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_OUTP_B_calc") #! Field("PPS:CLTS:1:HRTBT_OUTP_B_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_OUTP_B_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_OUTP_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb97.VAL") #! Field("PPS:CLTS:1:HRTBT_OUTP_B_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_OUTP_B_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_OUTP_B_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_OUTP_B_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_OUTP_B_calc.OUT","PPS:CLTS:1:HRTBT_OUTP_B.VAL") #! Record("PPS:CLTS:1:HRTBT_OUTP_B",500,20,0,0,"PPS:CLTS:1:HRTBT_OUTP_B") #! Field("PPS:CLTS:1:HRTBT_OUTP_B.VAL",16777215,1,"PPS:CLTS:1:HRTBT_OUTP_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi96") { field(DESC, "Port CLTS_RDB bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HWALRMWARN_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HWALRMWARN_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi96 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HWALRMWARN_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HWALRMWARN_B") { field(DESC, "RT-OUT ACR Hardware alarm/warning") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb96",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb96") #! Field("PLC:CLTS:PP14:CLTS_RDBb96.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb96.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb96.FLNK","PPS:CLTS:1:HWALRMWARN_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb96.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb96.VAL") #! Record("PPS:CLTS:1:HWALRMWARN_B_calc",260,18,0,1,"PPS:CLTS:1:HWALRMWARN_B_calc") #! Field("PPS:CLTS:1:HWALRMWARN_B_calc.INPA",16777215,0,"PPS:CLTS:1:HWALRMWARN_B_calc.INPA") #! Link("PPS:CLTS:1:HWALRMWARN_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb96.VAL") #! Field("PPS:CLTS:1:HWALRMWARN_B_calc.INPB",16777215,1,"PPS:CLTS:1:HWALRMWARN_B_calc.INPB") #! Field("PPS:CLTS:1:HWALRMWARN_B_calc.OUT",16777215,1,"PPS:CLTS:1:HWALRMWARN_B_calc.OUT") #! Link("PPS:CLTS:1:HWALRMWARN_B_calc.OUT","PPS:CLTS:1:HWALRMWARN_B.VAL") #! Record("PPS:CLTS:1:HWALRMWARN_B",500,20,0,0,"PPS:CLTS:1:HWALRMWARN_B") #! Field("PPS:CLTS:1:HWALRMWARN_B.VAL",16777215,1,"PPS:CLTS:1:HWALRMWARN_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi111") { field(DESC, "Port CLTS_RDB bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:HRTBT_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_OK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi111 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_OK_B") { field(DESC, "RT Heartbeat OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb111",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb111") #! Field("PLC:CLTS:PP14:CLTS_RDBb111.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb111.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb111.FLNK","PPS:CLTS:1:HRTBT_OK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb111.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb111.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_B_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_OK_B_calc") #! Field("PPS:CLTS:1:HRTBT_OK_B_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_OK_B_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_OK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb111.VAL") #! Field("PPS:CLTS:1:HRTBT_OK_B_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_OK_B_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_OK_B_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_OK_B_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_OK_B_calc.OUT","PPS:CLTS:1:HRTBT_OK_B.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_B",500,20,0,0,"PPS:CLTS:1:HRTBT_OK_B") #! Field("PPS:CLTS:1:HRTBT_OK_B.VAL",16777215,1,"PPS:CLTS:1:HRTBT_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi110") { field(DESC, "Port CLTS_RDB bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 110, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:1:HRTBT_OK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HRTBT_OK_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi110 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HRTBT_OK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HRTBT_OK_LTH_B") { field(DESC, "LAT Heartbeat OK") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb110",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb110") #! Field("PLC:CLTS:PP14:CLTS_RDBb110.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb110.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb110.FLNK","PPS:CLTS:1:HRTBT_OK_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb110.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb110.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_LTH_B_calc",260,18,0,1,"PPS:CLTS:1:HRTBT_OK_LTH_B_calc") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:1:HRTBT_OK_LTH_B_calc.INPA") #! Link("PPS:CLTS:1:HRTBT_OK_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb110.VAL") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:1:HRTBT_OK_LTH_B_calc.INPB") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:1:HRTBT_OK_LTH_B_calc.OUT") #! Link("PPS:CLTS:1:HRTBT_OK_LTH_B_calc.OUT","PPS:CLTS:1:HRTBT_OK_LTH_B.VAL") #! Record("PPS:CLTS:1:HRTBT_OK_LTH_B",500,20,0,0,"PPS:CLTS:1:HRTBT_OK_LTH_B") #! Field("PPS:CLTS:1:HRTBT_OK_LTH_B.VAL",16777215,1,"PPS:CLTS:1:HRTBT_OK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi109") { field(DESC, "Port CLTS_RDB bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:1:BCS_FAULT_OUT_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:BCS_FAULT_OUT_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi109 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:BCS_FAULT_OUT_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:BCS_FAULT_OUT_B") { field(DESC, "RT-OUT BCS Ok from PLC3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb109",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb109") #! Field("PLC:CLTS:PP14:CLTS_RDBb109.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb109.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb109.FLNK","PPS:CLTS:1:BCS_FAULT_OUT_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb109.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb109.VAL") #! Record("PPS:CLTS:1:BCS_FAULT_OUT_B_calc",260,18,0,1,"PPS:CLTS:1:BCS_FAULT_OUT_B_calc") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_B_calc.INPA",16777215,0,"PPS:CLTS:1:BCS_FAULT_OUT_B_calc.INPA") #! Link("PPS:CLTS:1:BCS_FAULT_OUT_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb109.VAL") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_B_calc.INPB",16777215,1,"PPS:CLTS:1:BCS_FAULT_OUT_B_calc.INPB") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_B_calc.OUT",16777215,1,"PPS:CLTS:1:BCS_FAULT_OUT_B_calc.OUT") #! Link("PPS:CLTS:1:BCS_FAULT_OUT_B_calc.OUT","PPS:CLTS:1:BCS_FAULT_OUT_B.VAL") #! Record("PPS:CLTS:1:BCS_FAULT_OUT_B",500,20,0,0,"PPS:CLTS:1:BCS_FAULT_OUT_B") #! Field("PPS:CLTS:1:BCS_FAULT_OUT_B.VAL",16777215,1,"PPS:CLTS:1:BCS_FAULT_OUT_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi108") { field(DESC, "Port CLTS_RDB bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 108, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:KICK_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_OFF_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi108 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_OFF_LTH_B") { field(DESC, "LAT CL-Kicker OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb108",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb108") #! Field("PLC:CLTS:PP14:CLTS_RDBb108.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb108.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb108.FLNK","PPS:CLTS:3:KICK_OFF_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb108.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb108.VAL") #! Record("PPS:CLTS:3:KICK_OFF_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_OFF_LTH_B_calc") #! Field("PPS:CLTS:3:KICK_OFF_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_OFF_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_OFF_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb108.VAL") #! Field("PPS:CLTS:3:KICK_OFF_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_OFF_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_OFF_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_OFF_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_OFF_LTH_B_calc.OUT","PPS:CLTS:3:KICK_OFF_LTH_B.VAL") #! Record("PPS:CLTS:3:KICK_OFF_LTH_B",500,20,0,0,"PPS:CLTS:3:KICK_OFF_LTH_B") #! Field("PPS:CLTS:3:KICK_OFF_LTH_B.VAL",16777215,1,"PPS:CLTS:3:KICK_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi107") { field(DESC, "Port CLTS_RDB bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 107, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:DCBEND_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_OFF_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi107 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_OFF_LTH_B") { field(DESC, "LAT CL-DC OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb107",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb107") #! Field("PLC:CLTS:PP14:CLTS_RDBb107.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb107.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb107.FLNK","PPS:CLTS:3:DCBEND_OFF_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb107.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb107.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_OFF_LTH_B_calc") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb107.VAL") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_OFF_LTH_B_calc.OUT","PPS:CLTS:3:DCBEND_OFF_LTH_B.VAL") #! Record("PPS:CLTS:3:DCBEND_OFF_LTH_B",500,20,0,0,"PPS:CLTS:3:DCBEND_OFF_LTH_B") #! Field("PPS:CLTS:3:DCBEND_OFF_LTH_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi106") { field(DESC, "Port CLTS_RDB bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 106, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:SEP_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_OFF_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi106 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_OFF_LTH_B") { field(DESC, "LAT CL-Septum OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb106",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb106") #! Field("PLC:CLTS:PP14:CLTS_RDBb106.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb106.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb106.FLNK","PPS:CLTS:3:SEP_OFF_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb106.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb106.VAL") #! Record("PPS:CLTS:3:SEP_OFF_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_OFF_LTH_B_calc") #! Field("PPS:CLTS:3:SEP_OFF_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_OFF_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_OFF_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb106.VAL") #! Field("PPS:CLTS:3:SEP_OFF_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_OFF_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_OFF_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_OFF_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_OFF_LTH_B_calc.OUT","PPS:CLTS:3:SEP_OFF_LTH_B.VAL") #! Record("PPS:CLTS:3:SEP_OFF_LTH_B",500,20,0,0,"PPS:CLTS:3:SEP_OFF_LTH_B") #! Field("PPS:CLTS:3:SEP_OFF_LTH_B.VAL",16777215,1,"PPS:CLTS:3:SEP_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi105") { field(DESC, "Port CLTS_RDB bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 105, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:MERGE_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_OFF_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi105 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_OFF_LTH_B") { field(DESC, "LAT CL-Merge OFF status") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb105",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb105") #! Field("PLC:CLTS:PP14:CLTS_RDBb105.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb105.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb105.FLNK","PPS:CLTS:3:MERGE_OFF_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb105.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb105.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_OFF_LTH_B_calc") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_OFF_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_OFF_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb105.VAL") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_OFF_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_OFF_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_OFF_LTH_B_calc.OUT","PPS:CLTS:3:MERGE_OFF_LTH_B.VAL") #! Record("PPS:CLTS:3:MERGE_OFF_LTH_B",500,20,0,0,"PPS:CLTS:3:MERGE_OFF_LTH_B") #! Field("PPS:CLTS:3:MERGE_OFF_LTH_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi104") { field(DESC, "Port CLTS_RDB bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 104, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi104 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B") { field(DESC, "LAT HX-KickerSepMrg Summary OFF") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb104",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb104") #! Field("PLC:CLTS:PP14:CLTS_RDBb104.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb104.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb104.FLNK","PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb104.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb104.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc",260,18,0,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.INPA",16777215,0,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.INPA") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb104.VAL") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.INPB",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.INPB") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.OUT",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.OUT") #! Link("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B_calc.OUT","PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B.VAL") #! Record("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B",500,20,0,0,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B") #! Field("PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B.VAL",16777215,1,"PPS:LI28:3:HXR:KICKSEP_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi119") { field(DESC, "Port CLTS_RDB bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 119, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi119 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B") { field(DESC, "LAT SX-KickerSepMrg Summary OFF") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb119",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb119") #! Field("PLC:CLTS:PP14:CLTS_RDBb119.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb119.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb119.FLNK","PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb119.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb119.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc",260,18,0,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.INPA",16777215,0,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.INPA") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb119.VAL") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.INPB",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.INPB") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.OUT",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.OUT") #! Link("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B_calc.OUT","PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B.VAL") #! Record("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B",500,20,0,0,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B") #! Field("PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B.VAL",16777215,1,"PPS:LI30:3:SXR:KICKSEP_OFF_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi118") { field(DESC, "Port CLTS_RDB bit 118") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 118, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:CLTS:585:3:IN_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:CLTS:585:3:IN_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi118 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:CLTS:585:3:IN_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:CLTS:585:3:IN_LTH_B") { field(DESC, "LAT STP-CLTS IN") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb118",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb118") #! Field("PLC:CLTS:PP14:CLTS_RDBb118.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb118.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb118.FLNK","STPR:CLTS:585:3:IN_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb118.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb118.VAL") #! Record("STPR:CLTS:585:3:IN_LTH_B_calc",260,18,0,1,"STPR:CLTS:585:3:IN_LTH_B_calc") #! Field("STPR:CLTS:585:3:IN_LTH_B_calc.INPA",16777215,0,"STPR:CLTS:585:3:IN_LTH_B_calc.INPA") #! Link("STPR:CLTS:585:3:IN_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb118.VAL") #! Field("STPR:CLTS:585:3:IN_LTH_B_calc.INPB",16777215,1,"STPR:CLTS:585:3:IN_LTH_B_calc.INPB") #! Field("STPR:CLTS:585:3:IN_LTH_B_calc.OUT",16777215,1,"STPR:CLTS:585:3:IN_LTH_B_calc.OUT") #! Link("STPR:CLTS:585:3:IN_LTH_B_calc.OUT","STPR:CLTS:585:3:IN_LTH_B.VAL") #! Record("STPR:CLTS:585:3:IN_LTH_B",500,20,0,0,"STPR:CLTS:585:3:IN_LTH_B") #! Field("STPR:CLTS:585:3:IN_LTH_B.VAL",16777215,1,"STPR:CLTS:585:3:IN_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi117") { field(DESC, "Port CLTS_RDB bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 117, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "STPR:BSYS:3:ST34_OUT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "STPR:BSYS:3:ST34_OUT_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi117 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "STPR:BSYS:3:ST34_OUT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "STPR:BSYS:3:ST34_OUT_LTH_B") { field(DESC, "LAT STP-34 Summary OUT") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb117",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb117") #! Field("PLC:CLTS:PP14:CLTS_RDBb117.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb117.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb117.FLNK","STPR:BSYS:3:ST34_OUT_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb117.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb117.VAL") #! Record("STPR:BSYS:3:ST34_OUT_LTH_B_calc",260,18,0,1,"STPR:BSYS:3:ST34_OUT_LTH_B_calc") #! Field("STPR:BSYS:3:ST34_OUT_LTH_B_calc.INPA",16777215,0,"STPR:BSYS:3:ST34_OUT_LTH_B_calc.INPA") #! Link("STPR:BSYS:3:ST34_OUT_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb117.VAL") #! Field("STPR:BSYS:3:ST34_OUT_LTH_B_calc.INPB",16777215,1,"STPR:BSYS:3:ST34_OUT_LTH_B_calc.INPB") #! Field("STPR:BSYS:3:ST34_OUT_LTH_B_calc.OUT",16777215,1,"STPR:BSYS:3:ST34_OUT_LTH_B_calc.OUT") #! Link("STPR:BSYS:3:ST34_OUT_LTH_B_calc.OUT","STPR:BSYS:3:ST34_OUT_LTH_B.VAL") #! Record("STPR:BSYS:3:ST34_OUT_LTH_B",500,20,0,0,"STPR:BSYS:3:ST34_OUT_LTH_B") #! Field("STPR:BSYS:3:ST34_OUT_LTH_B.VAL",16777215,1,"STPR:BSYS:3:ST34_OUT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi116") { field(DESC, "Port CLTS_RDB bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 116, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:1:ACR_ENABLE_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:ACR_ENABLE_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi116 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:ACR_ENABLE_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:ACR_ENABLE_LTH_B") { field(DESC, "LAT CLTS Admin Enable") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb116",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb116") #! Field("PLC:CLTS:PP14:CLTS_RDBb116.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb116.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb116.FLNK","PPS:CLTS:1:ACR_ENABLE_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb116.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb116.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_LTH_B_calc",260,18,0,1,"PPS:CLTS:1:ACR_ENABLE_LTH_B_calc") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.INPA") #! Link("PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb116.VAL") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.INPB") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.OUT") #! Link("PPS:CLTS:1:ACR_ENABLE_LTH_B_calc.OUT","PPS:CLTS:1:ACR_ENABLE_LTH_B.VAL") #! Record("PPS:CLTS:1:ACR_ENABLE_LTH_B",500,20,0,0,"PPS:CLTS:1:ACR_ENABLE_LTH_B") #! Field("PPS:CLTS:1:ACR_ENABLE_LTH_B.VAL",16777215,1,"PPS:CLTS:1:ACR_ENABLE_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi115") { field(DESC, "Port CLTS_RDB bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 115, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:KICK_INTLK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_INTLK_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi115 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_INTLK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_INTLK_LTH_B") { field(DESC, "LAT CL Kicker Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb115",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb115") #! Field("PLC:CLTS:PP14:CLTS_RDBb115.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb115.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb115.FLNK","PPS:CLTS:3:KICK_INTLK_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb115.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb115.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_INTLK_LTH_B_calc") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_INTLK_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_INTLK_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb115.VAL") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_INTLK_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_INTLK_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_INTLK_LTH_B_calc.OUT","PPS:CLTS:3:KICK_INTLK_LTH_B.VAL") #! Record("PPS:CLTS:3:KICK_INTLK_LTH_B",500,20,0,0,"PPS:CLTS:3:KICK_INTLK_LTH_B") #! Field("PPS:CLTS:3:KICK_INTLK_LTH_B.VAL",16777215,1,"PPS:CLTS:3:KICK_INTLK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi114") { field(DESC, "Port CLTS_RDB bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 114, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi114 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_INTLK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_INTLK_LTH_B") { field(DESC, "LAT CL DC Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb114",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb114") #! Field("PLC:CLTS:PP14:CLTS_RDBb114.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb114.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb114.FLNK","PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb114.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb114.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb114.VAL") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_INTLK_LTH_B_calc.OUT","PPS:CLTS:3:DCBEND_INTLK_LTH_B.VAL") #! Record("PPS:CLTS:3:DCBEND_INTLK_LTH_B",500,20,0,0,"PPS:CLTS:3:DCBEND_INTLK_LTH_B") #! Field("PPS:CLTS:3:DCBEND_INTLK_LTH_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_INTLK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi113") { field(DESC, "Port CLTS_RDB bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 113, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:SEP_INTLK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_INTLK_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi113 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_INTLK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_INTLK_LTH_B") { field(DESC, "LAT CL Septum Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb113",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb113") #! Field("PLC:CLTS:PP14:CLTS_RDBb113.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb113.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb113.FLNK","PPS:CLTS:3:SEP_INTLK_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb113.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb113.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_INTLK_LTH_B_calc") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_INTLK_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_INTLK_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb113.VAL") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_INTLK_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_INTLK_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_INTLK_LTH_B_calc.OUT","PPS:CLTS:3:SEP_INTLK_LTH_B.VAL") #! Record("PPS:CLTS:3:SEP_INTLK_LTH_B",500,20,0,0,"PPS:CLTS:3:SEP_INTLK_LTH_B") #! Field("PPS:CLTS:3:SEP_INTLK_LTH_B.VAL",16777215,1,"PPS:CLTS:3:SEP_INTLK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi112") { field(DESC, "Port CLTS_RDB bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 112, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:MERGE_INTLK_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_INTLK_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi112 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_INTLK_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_INTLK_LTH_B") { field(DESC, "LAT CL Merge Interlock") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb112",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb112") #! Field("PLC:CLTS:PP14:CLTS_RDBb112.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb112.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb112.FLNK","PPS:CLTS:3:MERGE_INTLK_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb112.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb112.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_INTLK_LTH_B_calc") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb112.VAL") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_INTLK_LTH_B_calc.OUT","PPS:CLTS:3:MERGE_INTLK_LTH_B.VAL") #! Record("PPS:CLTS:3:MERGE_INTLK_LTH_B",500,20,0,0,"PPS:CLTS:3:MERGE_INTLK_LTH_B") #! Field("PPS:CLTS:3:MERGE_INTLK_LTH_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_INTLK_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi127") { field(DESC, "Port CLTS_RDB bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 127, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:1:HB_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:1:HB_FAULT_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi127 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:1:HB_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:1:HB_FAULT_LTH_B") { field(DESC, "LAT Heartbeat Fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb127",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb127") #! Field("PLC:CLTS:PP14:CLTS_RDBb127.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb127.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb127.FLNK","PPS:CLTS:1:HB_FAULT_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb127.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb127.VAL") #! Record("PPS:CLTS:1:HB_FAULT_LTH_B_calc",260,18,0,1,"PPS:CLTS:1:HB_FAULT_LTH_B_calc") #! Field("PPS:CLTS:1:HB_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:1:HB_FAULT_LTH_B_calc.INPA") #! Link("PPS:CLTS:1:HB_FAULT_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb127.VAL") #! Field("PPS:CLTS:1:HB_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:1:HB_FAULT_LTH_B_calc.INPB") #! Field("PPS:CLTS:1:HB_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:1:HB_FAULT_LTH_B_calc.OUT") #! Link("PPS:CLTS:1:HB_FAULT_LTH_B_calc.OUT","PPS:CLTS:1:HB_FAULT_LTH_B.VAL") #! Record("PPS:CLTS:1:HB_FAULT_LTH_B",500,20,0,0,"PPS:CLTS:1:HB_FAULT_LTH_B") #! Field("PPS:CLTS:1:HB_FAULT_LTH_B.VAL",16777215,1,"PPS:CLTS:1:HB_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi126") { field(DESC, "Port CLTS_RDB bit 126") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 126, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:KICK_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_OK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi126 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_OK_B") { field(DESC, "RT CL-Kicker status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb126",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb126") #! Field("PLC:CLTS:PP14:CLTS_RDBb126.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb126.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb126.FLNK","PPS:CLTS:3:KICK_OK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb126.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb126.VAL") #! Record("PPS:CLTS:3:KICK_OK_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_OK_B_calc") #! Field("PPS:CLTS:3:KICK_OK_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_OK_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_OK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb126.VAL") #! Field("PPS:CLTS:3:KICK_OK_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_OK_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_OK_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_OK_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_OK_B_calc.OUT","PPS:CLTS:3:KICK_OK_B.VAL") #! Record("PPS:CLTS:3:KICK_OK_B",500,20,0,0,"PPS:CLTS:3:KICK_OK_B") #! Field("PPS:CLTS:3:KICK_OK_B.VAL",16777215,1,"PPS:CLTS:3:KICK_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi125") { field(DESC, "Port CLTS_RDB bit 125") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 125, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:DCBEND_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_OK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi125 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_OK_B") { field(DESC, "RT CL-DC status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb125",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb125") #! Field("PLC:CLTS:PP14:CLTS_RDBb125.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb125.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb125.FLNK","PPS:CLTS:3:DCBEND_OK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb125.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb125.VAL") #! Record("PPS:CLTS:3:DCBEND_OK_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_OK_B_calc") #! Field("PPS:CLTS:3:DCBEND_OK_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_OK_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_OK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb125.VAL") #! Field("PPS:CLTS:3:DCBEND_OK_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_OK_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_OK_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_OK_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_OK_B_calc.OUT","PPS:CLTS:3:DCBEND_OK_B.VAL") #! Record("PPS:CLTS:3:DCBEND_OK_B",500,20,0,0,"PPS:CLTS:3:DCBEND_OK_B") #! Field("PPS:CLTS:3:DCBEND_OK_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi124") { field(DESC, "Port CLTS_RDB bit 124") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 124, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:SEP_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_OK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi124 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_OK_B") { field(DESC, "RT CL-Septum status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb124",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb124") #! Field("PLC:CLTS:PP14:CLTS_RDBb124.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb124.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb124.FLNK","PPS:CLTS:3:SEP_OK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb124.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb124.VAL") #! Record("PPS:CLTS:3:SEP_OK_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_OK_B_calc") #! Field("PPS:CLTS:3:SEP_OK_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_OK_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_OK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb124.VAL") #! Field("PPS:CLTS:3:SEP_OK_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_OK_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_OK_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_OK_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_OK_B_calc.OUT","PPS:CLTS:3:SEP_OK_B.VAL") #! Record("PPS:CLTS:3:SEP_OK_B",500,20,0,0,"PPS:CLTS:3:SEP_OK_B") #! Field("PPS:CLTS:3:SEP_OK_B.VAL",16777215,1,"PPS:CLTS:3:SEP_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi123") { field(DESC, "Port CLTS_RDB bit 123") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 123, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "PPS:CLTS:3:MERGE_OK_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_OK_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi123 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_OK_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_OK_B") { field(DESC, "RT CL-Merge status OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb123",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb123") #! Field("PLC:CLTS:PP14:CLTS_RDBb123.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb123.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb123.FLNK","PPS:CLTS:3:MERGE_OK_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb123.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb123.VAL") #! Record("PPS:CLTS:3:MERGE_OK_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_OK_B_calc") #! Field("PPS:CLTS:3:MERGE_OK_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_OK_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_OK_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb123.VAL") #! Field("PPS:CLTS:3:MERGE_OK_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_OK_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_OK_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_OK_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_OK_B_calc.OUT","PPS:CLTS:3:MERGE_OK_B.VAL") #! Record("PPS:CLTS:3:MERGE_OK_B",500,20,0,0,"PPS:CLTS:3:MERGE_OK_B") #! Field("PPS:CLTS:3:MERGE_OK_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_OK_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi122") { field(DESC, "Port CLTS_RDB bit 122") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 122, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:KICK_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:KICK_FAULT_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi122 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:KICK_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:KICK_FAULT_LTH_B") { field(DESC, "LAT CL-Kicker status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb122",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb122") #! Field("PLC:CLTS:PP14:CLTS_RDBb122.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb122.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb122.FLNK","PPS:CLTS:3:KICK_FAULT_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb122.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb122.VAL") #! Record("PPS:CLTS:3:KICK_FAULT_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:KICK_FAULT_LTH_B_calc") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:KICK_FAULT_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:KICK_FAULT_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb122.VAL") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:KICK_FAULT_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:KICK_FAULT_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:KICK_FAULT_LTH_B_calc.OUT","PPS:CLTS:3:KICK_FAULT_LTH_B.VAL") #! Record("PPS:CLTS:3:KICK_FAULT_LTH_B",500,20,0,0,"PPS:CLTS:3:KICK_FAULT_LTH_B") #! Field("PPS:CLTS:3:KICK_FAULT_LTH_B.VAL",16777215,1,"PPS:CLTS:3:KICK_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi121") { field(DESC, "Port CLTS_RDB bit 121") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 121, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi121 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:DCBEND_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:DCBEND_FAULT_LTH_B") { field(DESC, "LAT CL-DC status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb121",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb121") #! Field("PLC:CLTS:PP14:CLTS_RDBb121.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb121.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb121.FLNK","PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb121.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb121.VAL") #! Record("PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb121.VAL") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:DCBEND_FAULT_LTH_B_calc.OUT","PPS:CLTS:3:DCBEND_FAULT_LTH_B.VAL") #! Record("PPS:CLTS:3:DCBEND_FAULT_LTH_B",500,20,0,0,"PPS:CLTS:3:DCBEND_FAULT_LTH_B") #! Field("PPS:CLTS:3:DCBEND_FAULT_LTH_B.VAL",16777215,1,"PPS:CLTS:3:DCBEND_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi120") { field(DESC, "Port CLTS_RDB bit 120") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 120, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:SEP_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:SEP_FAULT_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi120 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:SEP_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:SEP_FAULT_LTH_B") { field(DESC, "LAT CL-Septum status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb120",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb120") #! Field("PLC:CLTS:PP14:CLTS_RDBb120.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb120.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb120.FLNK","PPS:CLTS:3:SEP_FAULT_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb120.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb120.VAL") #! Record("PPS:CLTS:3:SEP_FAULT_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:SEP_FAULT_LTH_B_calc") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:SEP_FAULT_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:SEP_FAULT_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb120.VAL") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:SEP_FAULT_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:SEP_FAULT_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:SEP_FAULT_LTH_B_calc.OUT","PPS:CLTS:3:SEP_FAULT_LTH_B.VAL") #! Record("PPS:CLTS:3:SEP_FAULT_LTH_B",500,20,0,0,"PPS:CLTS:3:SEP_FAULT_LTH_B") #! Field("PPS:CLTS:3:SEP_FAULT_LTH_B.VAL",16777215,1,"PPS:CLTS:3:SEP_FAULT_LTH_B.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:CLTS:PP14:Bi135") { field(DESC, "Port CLTS_RDB bit 135") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 135, 1, 1)") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(FLNK, "PPS:CLTS:3:MERGE_FAULT_LTH_B_calc PP MS") field(ASG, "Internal") } record(calcout, "PPS:CLTS:3:MERGE_FAULT_LTH_B_calc") { field(INPA, "PLC:CLTS:PP14:Bi135 NPP MS") field(INPB, "PLC:CLTS:PP14:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PPS:CLTS:3:MERGE_FAULT_LTH_B PP MS") field(ASG, "Internal") } record(bi, "PPS:CLTS:3:MERGE_FAULT_LTH_B") { field(DESC, "LAT CL-Merge status fault") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:CLTS:PP14:CLTS_RDBb135",20,19,0,0,"PLC:CLTS:PP14:CLTS_RDBb135") #! Field("PLC:CLTS:PP14:CLTS_RDBb135.FLNK",16777215,1,"PLC:CLTS:PP14:CLTS_RDBb135.FLNK") #! Link("PLC:CLTS:PP14:CLTS_RDBb135.FLNK","PPS:CLTS:3:MERGE_FAULT_LTH_B_calc") #! Field("PLC:CLTS:PP14:CLTS_RDBb135.VAL",16777215,0,"PLC:CLTS:PP14:CLTS_RDBb135.VAL") #! Record("PPS:CLTS:3:MERGE_FAULT_LTH_B_calc",260,18,0,1,"PPS:CLTS:3:MERGE_FAULT_LTH_B_calc") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.INPA",16777215,0,"PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.INPA") #! Link("PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.INPA","PLC:CLTS:PP14:CLTS_RDBb135.VAL") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.INPB",16777215,1,"PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.INPB") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.OUT",16777215,1,"PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.OUT") #! Link("PPS:CLTS:3:MERGE_FAULT_LTH_B_calc.OUT","PPS:CLTS:3:MERGE_FAULT_LTH_B.VAL") #! Record("PPS:CLTS:3:MERGE_FAULT_LTH_B",500,20,0,0,"PPS:CLTS:3:MERGE_FAULT_LTH_B") #! Field("PPS:CLTS:3:MERGE_FAULT_LTH_B.VAL",16777215,1,"PPS:CLTS:3:MERGE_FAULT_LTH_B.VAL") record(bo, "PPS:CLTS:1:RESET_INTLK_B") { field(DESC, "PPS_Interlock_Reset_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } record(bo, "PPS:CLTS:1:PAUSEHB_B") { field(DESC, "PPS_Pause_Heartbeat_B") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:CLTS:PP14:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:CLTS:PP14:TABLE_CYCLER") { field( OUT, "PLC:CLTS:PP14:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:CLTS:PP14:SEG_CYCLER") { field( OUT, "PLC:CLTS:PP14:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:CLTS:PP14:TABLE_9_SEG_1") { field( INPA, "PLC:CLTS:PP14:REQ_TABLE CP") field( INPB, "PLC:CLTS:PP14:REQ_SEG CP") field( INPC, "PLC:CLTS:PP14:REQ_TABLE_IN CP") field( INPD, "PLC:CLTS:PP14:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:CLTS:PP14:TABLE_1_SEG_1") { field( INPA, "PLC:CLTS:PP14:REQ_TABLE CP") field( INPB, "PLC:CLTS:PP14:REQ_SEG CP") field( INPC, "PLC:CLTS:PP14:REQ_TABLE_IN CP") field( INPD, "PLC:CLTS:PP14:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:CLTS:PP14:REQ_TABLE_OUT") { field(OUTA, "PLC:CLTS:PP14:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:CLTS:PP14:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:CLTS:PP14:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:CLTS:PP14:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:CLTS:PP14:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:CLTS:PP14:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:CLTS:PP14:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:CLTS:PP14:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:CLTS:PP14:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT0 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT1 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT2 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT3 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT4 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT5 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT6 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_TABLE_OUT") field(INPB, "PLC:CLTS:PP14:TABLE_BIT7 MS") field(INPC, "PLC:CLTS:PP14:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:CLTS:PP14:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:CLTS:PP14:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:CLTS:PP14:TABLE_BIT0 CP MS") field(INPB, "PLC:CLTS:PP14:TABLE_BIT1 CP MS") field(INPC, "PLC:CLTS:PP14:TABLE_BIT2 CP MS") field(INPD, "PLC:CLTS:PP14:TABLE_BIT3 CP MS") field(INPE, "PLC:CLTS:PP14:TABLE_BIT4 CP MS") field(INPF, "PLC:CLTS:PP14:TABLE_BIT5 CP MS") field(INPG, "PLC:CLTS:PP14:TABLE_BIT6 CP MS") field(INPH, "PLC:CLTS:PP14:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:CLTS:PP14:REQ_TABLE PP MS") #field(SDIS, "PLC:CLTS:PP14:REQ_TABLE_OUT.PACT") } record(longout, "PLC:CLTS:PP14:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:CLTS:PP14:REQ_SEG_OUT") { field(OUTA, "PLC:CLTS:PP14:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:CLTS:PP14:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:CLTS:PP14:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:CLTS:PP14:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:CLTS:PP14:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:CLTS:PP14:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:CLTS:PP14:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:CLTS:PP14:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:CLTS:PP14:REQ_SEG_IN.PACT") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT0 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT1 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT1 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT2 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT2 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT3 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT3 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT4 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT4 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT5 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT5 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT6 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT6 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:CLTS:PP14:REQ_SEG_OUT") field(INPB, "PLC:CLTS:PP14:SEG_BIT7 MS") field(INPC, "PLC:CLTS:PP14:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:CLTS:PP14:REQ_SEG_BIT7 PP") } record(calcout, "PLC:CLTS:PP14:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:CLTS:PP14:SEG_BIT0 CP MS") field(INPB, "PLC:CLTS:PP14:SEG_BIT1 CP MS") field(INPC, "PLC:CLTS:PP14:SEG_BIT2 CP MS") field(INPD, "PLC:CLTS:PP14:SEG_BIT3 CP MS") field(INPE, "PLC:CLTS:PP14:SEG_BIT4 CP MS") field(INPF, "PLC:CLTS:PP14:SEG_BIT5 CP MS") field(INPG, "PLC:CLTS:PP14:SEG_BIT6 CP MS") field(INPH, "PLC:CLTS:PP14:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:CLTS:PP14:REQ_SEG PP MS") field(SDIS, "PLC:CLTS:PP14:REQ_SEG_OUT.PACT") } record(bi, "PLC:CLTS:PP14:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:PWLED") { field(DESC, "ODM-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:RUNLED") { field(DESC, "ODM-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:DIAGLED") { field(DESC, "ODM-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:FAULTLED") { field(DESC, "ODM-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:IFAULTLED") { field(DESC, "ODM-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:OFAULTLED") { field(DESC, "ODM-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:CLTS:PP14:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_RDB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:CLTS:PP14:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(CLTS_WRTB, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:CLTS:PP14:w0") { field(DESC, "CLTS CHAINB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:w1") { field(DESC, "CLTS CHAINB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 2, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:CLTS:PP14:CHECKSUM_SDIS") { field(INPA, "PLC:CLTS:PP14:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:CLTS:PP14:w3") { field(DESC, "CLTS CHAINB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 3, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP14:CHECKSUM_SAFE_calc") { field(INPA, "PLC:CLTS:PP14:w3 PP MS") field(INPB, "PLC:CLTS:PP14:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP14:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:CLTS:PP14:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP14:w4") { field(DESC, "CLTS CHAINB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 4, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP14:PROJ_CHECKSUM_calc") { field(INPA, "PLC:CLTS:PP14:w4 NPP MS") field(INPB, "PLC:CLTS:PP14:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP14:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP14:w5") { field(DESC, "CLTS CHAINB Checksum") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 5, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP14:DAY_MONTH_calc") { field(INPA, "PLC:CLTS:PP14:w5 NPP MS") field(INPB, "PLC:CLTS:PP14:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP14:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:CLTS:PP14:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:CLTS:PP14:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:CLTS:PP14:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:CLTS:PP14:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP14:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 6, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP14:PROJ_YEAR_calc") { field(INPA, "PLC:CLTS:PP14:w6 NPP MS") field(INPB, "PLC:CLTS:PP14:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP14:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:CLTS:PP14:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 7, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP14:OP_HRS_MSB_calc") { field(INPA, "PLC:CLTS:PP14:w7 NPP MS") field(INPB, "PLC:CLTS:PP14:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP14:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(CLTS_WDB, 8, 0xFFFF, 1)") field(FLNK, "PLC:CLTS:PP14:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:CLTS:PP14:OP_HRS_LSB_calc") { field(INPA, "PLC:CLTS:PP14:w8 NPP MS") field(INPB, "PLC:CLTS:PP14:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:CLTS:PP14:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:CLTS:PP14:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:CLTS:PP14:OP_HOURS") { field(INPA, "PLC:CLTS:PP14:OP_HRS_MSB CP MS") field(INPB, "PLC:CLTS:PP14:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:CLTS:PP14:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:CLTS:PP14:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:CLTS:PP14:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(CLTS_RDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:CLTS:PP14:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:CLTS:PP14:RDHist.PROC") } record(waveform,"PLC:CLTS:PP14:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_RDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP14:RDHistTimeAxis.PROC") } record(waveform,"PLC:CLTS:PP14:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_RDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP14:RDReadOK.PROC") } record(longout,"PLC:CLTS:PP14:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(CLTS_RDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:CLTS:PP14:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDB 0)READ_OK") field(FLNK,"PLC:CLTS:PP14:RDWriteOK.PROC") } record(longin,"PLC:CLTS:PP14:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDB 0)WRITE_OK") field(FLNK,"PLC:CLTS:PP14:RDIOErrors.PROC") } record(longin,"PLC:CLTS:PP14:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDB 0)IO_ERRORS") field(FLNK,"PLC:CLTS:PP14:RDLastIOTime.PROC") } record(longin,"PLC:CLTS:PP14:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDB 0)LAST_IO_TIME") field(FLNK,"PLC:CLTS:PP14:RDMaxIOTime.PROC") } record(longin,"PLC:CLTS:PP14:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_RDB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:CLTS:PP14:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(CLTS_WRTB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:CLTS:PP14:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:CLTS:PP14:WRTHist.PROC") } record(waveform,"PLC:CLTS:PP14:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WRTB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP14:WRTHistTimeAxis.PROC") } record(waveform,"PLC:CLTS:PP14:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WRTB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP14:WRTReadOK.PROC") } record(longout,"PLC:CLTS:PP14:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(CLTS_WRTB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:CLTS:PP14:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTB 0)READ_OK") field(FLNK,"PLC:CLTS:PP14:WRTWriteOK.PROC") } record(longin,"PLC:CLTS:PP14:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTB 0)WRITE_OK") field(FLNK,"PLC:CLTS:PP14:WRTIOErrors.PROC") } record(longin,"PLC:CLTS:PP14:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTB 0)IO_ERRORS") field(FLNK,"PLC:CLTS:PP14:WRTLastIOTime.PROC") } record(longin,"PLC:CLTS:PP14:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTB 0)LAST_IO_TIME") field(FLNK,"PLC:CLTS:PP14:WRTMaxIOTime.PROC") } record(longin,"PLC:CLTS:PP14:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WRTB 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:CLTS:PP14:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(CLTS_WDB 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:CLTS:PP14:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:CLTS:PP14:WDHist.PROC") } record(waveform,"PLC:CLTS:PP14:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WDB 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP14:WDHistTimeAxis.PROC") } record(waveform,"PLC:CLTS:PP14:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(CLTS_WDB 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:CLTS:PP14:WDReadOK.PROC") } record(longout,"PLC:CLTS:PP14:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(CLTS_WDB 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:CLTS:PP14:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDB 0)READ_OK") field(FLNK,"PLC:CLTS:PP14:WDWriteOK.PROC") } record(longin,"PLC:CLTS:PP14:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDB 0)WRITE_OK") field(FLNK,"PLC:CLTS:PP14:WDIOErrors.PROC") } record(longin,"PLC:CLTS:PP14:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDB 0)IO_ERRORS") field(FLNK,"PLC:CLTS:PP14:WDLastIOTime.PROC") } record(longin,"PLC:CLTS:PP14:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDB 0)LAST_IO_TIME") field(FLNK,"PLC:CLTS:PP14:WDMaxIOTime.PROC") } record(longin,"PLC:CLTS:PP14:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(CLTS_WDB 0)MAX_IO_TIME") } record(bo, "PPS:BSYH:1:STPRBTHINSET") { field(DESC, "Send STD2 Set In") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYH:1:STPRBTHINSET_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYH:1:STPRBTHINSET_DFO") { field(DESC, "Send STD2 Set In dfanout") field(DOL, "PPS:BSYH:1:STPRBTHINSET") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYH:1:STPRBTHINSET_A PP") field(OUTB, "PPS:BSYH:1:STPRBTHINSET_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STPRBTHOUTST") { field(DESC, "Send STD2 Set Out") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYH:1:STPRBTHOUTST_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYH:1:STPRBTHOUTST_DFO") { field(DESC, "Send STD2 Set Out dfanout") field(DOL, "PPS:BSYH:1:STPRBTHOUTST") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYH:1:STPRBTHOUTST_A PP") field(OUTB, "PPS:BSYH:1:STPRBTHOUTST_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYH:1:STD2:RESET_INTLK") { field(DESC, "STD2 Intlk Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYH:1:STD2:RESET_INTLK_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYH:1:STD2:RESET_INTLK_DFO") { field(DESC, "STD2 Intlk Reset dfanout") field(DOL, "PPS:BSYH:1:STD2:RESET_INTLK") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYH:1:STD2:RESET_INTLK_A PP") field(OUTB, "PPS:BSYH:1:STD2:RESET_INTLK_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:SYSE:1:30BSY:RESET_INTLK") { field(DESC, "30BSY Intlk Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:SYSE:1:30BSY:RESET_INTLK_DFO") field(ASG, "MCC") } record(dfanout, "PPS:SYSE:1:30BSY:RESET_INTLK_DFO") { field(DESC, "30BSY Intlk Reset dfanout") field(DOL, "PPS:SYSE:1:30BSY:RESET_INTLK") field(OMSL, "closed_loop") field(OUTA, "PPS:SYSE:1:30BSY:RESET_INTLK_A PP") field(OUTB, "PPS:SYSE:1:30BSY:RESET_INTLK_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:SET_IN") { field(DESC, "Send ST34 Set In") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYS:1:ST34:SET_IN_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYS:1:ST34:SET_IN_DFO") { field(DESC, "Send ST34 Set In dfanout") field(DOL, "PPS:BSYS:1:ST34:SET_IN") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYS:1:ST34:SET_IN_A PP") field(OUTB, "PPS:BSYS:1:ST34:SET_IN_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:SET_OUT") { field(DESC, "Send ST34 Set Out") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYS:1:ST34:SET_OUT_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYS:1:ST34:SET_OUT_DFO") { field(DESC, "Send ST34 Set Out dfanout") field(DOL, "PPS:BSYS:1:ST34:SET_OUT") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYS:1:ST34:SET_OUT_A PP") field(OUTB, "PPS:BSYS:1:ST34:SET_OUT_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:STCLTS:SET_IN") { field(DESC, "Send STCLTS Set In") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYS:1:STCLTS:SET_IN_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYS:1:STCLTS:SET_IN_DFO") { field(DESC, "Send STCLTS Set In dfanout") field(DOL, "PPS:BSYS:1:STCLTS:SET_IN") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYS:1:STCLTS:SET_IN_A PP") field(OUTB, "PPS:BSYS:1:STCLTS:SET_IN_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:STCLTS:SET_OUT") { field(DESC, "Send STCLTS Set Out") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYS:1:STCLTS:SET_OUT_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYS:1:STCLTS:SET_OUT_DFO") { field(DESC, "Send STCLTS Set Out dfanout") field(DOL, "PPS:BSYS:1:STCLTS:SET_OUT") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYS:1:STCLTS:SET_OUT_A PP") field(OUTB, "PPS:BSYS:1:STCLTS:SET_OUT_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:BSYS:1:ST34:RESET_INTLK") { field(DESC, "ST34 Intlk Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:BSYS:1:ST34:RESET_INTLK_DFO") field(ASG, "MCC") } record(dfanout, "PPS:BSYS:1:ST34:RESET_INTLK_DFO") { field(DESC, "ST34 Intlk Reset dfanout") field(DOL, "PPS:BSYS:1:ST34:RESET_INTLK") field(OMSL, "closed_loop") field(OUTA, "PPS:BSYS:1:ST34:RESET_INTLK_A PP") field(OUTB, "PPS:BSYS:1:ST34:RESET_INTLK_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:CLTS:1:RESET_INTLK") { field(DESC, "CLTS Intlk Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:CLTS:1:RESET_INTLK_DFO") field(ASG, "MCC") } record(dfanout, "PPS:CLTS:1:RESET_INTLK_DFO") { field(DESC, "CLTS Intlk Reset dfanout") field(DOL, "PPS:CLTS:1:RESET_INTLK") field(OMSL, "closed_loop") field(OUTA, "PPS:CLTS:1:RESET_INTLK_A PP") field(OUTB, "PPS:CLTS:1:RESET_INTLK_B PP") field(OUTC, " PP") field(ASG, "MCC") } record(calc, "STPR:BSYH:847:INCALC") { field(SCAN, ".1 second") field(DESC, "STD2 IN Sum Calc") field(FLNK, "STPR:BSYH:847:IN") field(CALC, "A&&B") field(INPA, "STPR:BSYH:847:INA MS") field(INPB, "STPR:BSYH:847:INB MS") } record(bi, "STPR:BSYH:847:IN") { field(SCAN, "Passive") field(DESC, "STD2 IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "STPR:BSYH:847:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "STPR:BSYH:847:OUTCALC") { field(SCAN, ".1 second") field(DESC, "STD2 OUT Sum Calc") field(FLNK, "STPR:BSYH:847:OUT") field(CALC, "A&&B") field(INPA, "STPR:BSYH:847:OUTA MS") field(INPB, "STPR:BSYH:847:OUTB MS") } record(bi, "STPR:BSYH:847:OUT") { field(SCAN, "Passive") field(DESC, "STD2 OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "STPR:BSYH:847:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "STPR:BSYH:854:INCALC") { field(SCAN, ".1 second") field(DESC, "ST60 IN Sum Calc") field(FLNK, "STPR:BSYH:854:IN") field(CALC, "A&&B") field(INPA, "STPR:BSYH:854:INA MS") field(INPB, "STPR:BSYH:854:INB MS") } record(bi, "STPR:BSYH:854:IN") { field(SCAN, "Passive") field(DESC, "ST60 IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "STPR:BSYH:854:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "STPR:BSYH:854:OUTCALC") { field(SCAN, ".1 second") field(DESC, "ST60 OUT Sum Calc") field(FLNK, "STPR:BSYH:854:OUT") field(CALC, "A&&B") field(INPA, "STPR:BSYH:854:OUTA MS") field(INPB, "STPR:BSYH:854:OUTB MS") } record(bi, "STPR:BSYH:854:OUT") { field(SCAN, "Passive") field(DESC, "ST60 OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "STPR:BSYH:854:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "STPR:BSYH:905:INCALC") { field(SCAN, ".1 second") field(DESC, "ST61 IN Sum Calc") field(FLNK, "STPR:BSYH:905:IN") field(CALC, "A&&B") field(INPA, "STPR:BSYH:905:INA MS") field(INPB, "STPR:BSYH:905:INB MS") } record(bi, "STPR:BSYH:905:IN") { field(SCAN, "Passive") field(DESC, "ST61 IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "STPR:BSYH:905:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "STPR:BSYH:905:OUTCALC") { field(SCAN, ".1 second") field(DESC, "ST61 OUT Sum Calc") field(FLNK, "STPR:BSYH:905:OUT") field(CALC, "A&&B") field(INPA, "STPR:BSYH:905:OUTA MS") field(INPB, "STPR:BSYH:905:OUTB MS") } record(bi, "STPR:BSYH:905:OUT") { field(SCAN, "Passive") field(DESC, "ST61 OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "STPR:BSYH:905:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "BTM:BSYH:858:INCALC") { field(SCAN, ".1 second") field(DESC, "DM60 IN Sum Calc") field(FLNK, "BTM:BSYH:858:IN") field(CALC, "A&&B") field(INPA, "BTM:BSYH:858:INA MS") field(INPB, "BTM:BSYH:858:INB MS") } record(bi, "BTM:BSYH:858:IN") { field(SCAN, "Passive") field(DESC, "DM60 IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "BTM:BSYH:858:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "BTM:BSYH:858:OUTCALC") { field(SCAN, ".1 second") field(DESC, "DM60 OUT Sum Calc") field(FLNK, "BTM:BSYH:858:OUT") field(CALC, "A&&B") field(INPA, "BTM:BSYH:858:OUTA MS") field(INPB, "BTM:BSYH:858:OUTB MS") } record(bi, "BTM:BSYH:858:OUT") { field(SCAN, "Passive") field(DESC, "DM60 OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "BTM:BSYH:858:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:LI28:1:HXR:KICK_OFFCALC") { field(SCAN, ".1 second") field(DESC, "SC HXR Kicker Off Sum Calc") field(FLNK, "PPS:LI28:1:HXR:KICK_OFF") field(CALC, "A&&B") field(INPA, "PPS:LI28:1:HXR:KICK_OFF_A MS") field(INPB, "PPS:LI28:1:HXR:KICK_OFF_B MS") } record(bi, "PPS:LI28:1:HXR:KICK_OFF") { field(SCAN, "Passive") field(DESC, "SC HXR Kicker Off Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OFF") field(ONAM, "OFF") field(INP, "PPS:LI28:1:HXR:KICK_OFFCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:LI28:1:HXR:KICK_OFF_LTHCALC") { field(SCAN, ".1 second") field(DESC, "HXR_Kicker_Off_Sum_Lat_Calc") field(FLNK, "PPS:LI28:1:HXR:KICK_OFF_LTH") field(CALC, "A&&B") field(INPA, "PPS:LI28:1:HXR:KICK_OFF_LTH_A MS") field(INPB, "PPS:LI28:1:HXR:KICK_OFF_LTH_B MS") } record(bi, "PPS:LI28:1:HXR:KICK_OFF_LTH") { field(SCAN, "Passive") field(DESC, "HXR_Kicker_Off_Sum_Lat") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "PPS:LI28:1:HXR:KICK_OFF_LTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYH:1:STD2:PERMCALC") { field(SCAN, ".1 second") field(DESC, "STD2 Sum Calc") field(FLNK, "PPS:BSYH:1:STD2:PERMITTED") field(CALC, "A&&B") field(INPA, "PPS:BSYH:1:STD2:PERMITTED_A MS") field(INPB, "PPS:BSYH:1:STD2:PERMITTED_B MS") } record(bi, "PPS:BSYH:1:STD2:PERMITTED") { field(SCAN, "Passive") field(DESC, "STD2 Set Permit") field(DTYP, "Soft Channel") field(ZNAM, "NOT_PERMITTED") field(ONAM, "PERMITTED") field(INP, "PPS:BSYH:1:STD2:PERMCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYH:1:STD2:STOP_ENBLCALC") { field(SCAN, ".1 second") field(DESC, "STD2 Enable Calc") field(FLNK, "PPS:BSYH:1:STD2:STOPPER_ENABLE") field(CALC, "A&&B") field(INPA, "PPS:BSYH:1:STD2:STOPPER_ENABLE_A MS") field(INPB, "PPS:BSYH:1:STD2:STOPPER_ENABLE_B MS") } record(bi, "PPS:BSYH:1:STD2:STOPPER_ENABLE") { field(SCAN, "Passive") field(DESC, "Local STD2 Stopper Enable") field(DTYP, "Soft Channel") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(INP, "PPS:BSYH:1:STD2:STOP_ENBLCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYH:1:STD2:STOP_ENBL_LTHCALC") { field(SCAN, ".1 second") field(DESC, "STD2 Enable Latch CALC") field(FLNK, "PPS:BSYH:1:STD2:STOP_ENBL_LTH") field(CALC, "A&&B") field(INPA, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_A MS") field(INPB, "PPS:BSYH:1:STD2:STOP_ENBL_LTH_B MS") } record(bi, "PPS:BSYH:1:STD2:STOP_ENBL_LTH") { field(SCAN, "Passive") field(DESC, "Local_STD2_Enable_Keysw") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "PPS:BSYH:1:STD2:STOP_ENBL_LTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYH:1:STD2_ADMIN_EN_LTHCALC") { field(SCAN, ".1 second") field(DESC, "ACR_STD2_Enable_Keysw_Calc") field(FLNK, "PPS:BSYH:1:STD2_ADMIN_EN_LTH") field(CALC, "A&&B") field(INPA, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_A MS") field(INPB, "PPS:BSYH:1:STD2_ADMIN_EN_LTH_B MS") } record(bi, "PPS:BSYH:1:STD2_ADMIN_EN_LTH") { field(SCAN, "Passive") field(DESC, "ACR_STD2_Enable_Keysw") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "PPS:BSYH:1:STD2_ADMIN_EN_LTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYH:1:STD2_ADMIN_ENCALC") { field(SCAN, ".1 second") field(DESC, "STD2_Enable_Keysw_Calc") field(FLNK, "PPS:BSYH:1:STD2_ADMIN_EN") field(CALC, "A&&B") field(INPA, "PPS:BSYH:1:STD2_ADMIN_EN_A MS") field(INPB, "PPS:BSYH:1:STD2_ADMIN_EN_B MS") } record(bi, "PPS:BSYH:1:STD2_ADMIN_EN") { field(SCAN, "Passive") field(DESC, "STD2_Enable_Keysw") field(DTYP, "Soft Channel") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(INP, "PPS:BSYH:1:STD2_ADMIN_ENCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:LTU0:1:ACCPERMIT_OUTCALC") { field(SCAN, ".1 second") field(DESC, "BTH_UND_Access_Permit_Calc") field(FLNK, "PPS:LTU0:1:ACCPERMIT_OUT") field(CALC, "A&&B") field(INPA, "PPS:LTU0:1:ACCPERMIT_OUT_A MS") field(INPB, "PPS:LTU0:1:ACCPERMIT_OUT_B MS") } record(bi, "PPS:LTU0:1:ACCPERMIT_OUT") { field(SCAN, "Passive") field(DESC, "BTH_UND_Access_Permit") field(DTYP, "Soft Channel") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(INP, "PPS:LTU0:1:ACCPERMIT_OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:ST34A:INCALC") { field(SCAN, ".1 second") field(DESC, "ST34A IN Sum Calc") field(FLNK, "PPS:BSYS:1:ST34A:IN") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34A:IN_A MS") field(INPB, "PPS:BSYS:1:ST34A:IN_B MS") } record(bi, "PPS:BSYS:1:ST34A:IN") { field(SCAN, "Passive") field(DESC, "ST34A IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "PPS:BSYS:1:ST34A:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "PPS:BSYS:1:ST34A:OUTCALC") { field(SCAN, ".1 second") field(DESC, "ST34A OUT Sum Calc") field(FLNK, "PPS:BSYS:1:ST34A:OUT") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34A:OUT_A MS") field(INPB, "PPS:BSYS:1:ST34A:OUT_B MS") } record(bi, "PPS:BSYS:1:ST34A:OUT") { field(SCAN, "Passive") field(DESC, "ST34A OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "PPS:BSYS:1:ST34A:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:ST34B:INCALC") { field(SCAN, ".1 second") field(DESC, "ST34B IN Sum Calc") field(FLNK, "PPS:BSYS:1:ST34B:IN") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34B:IN_A MS") field(INPB, "PPS:BSYS:1:ST34B:IN_B MS") } record(bi, "PPS:BSYS:1:ST34B:IN") { field(SCAN, "Passive") field(DESC, "ST34B IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "PPS:BSYS:1:ST34B:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "PPS:BSYS:1:ST34B:OUTCALC") { field(SCAN, ".1 second") field(DESC, "ST34B OUT Sum Calc") field(FLNK, "PPS:BSYS:1:ST34B:OUT") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34B:OUT_A MS") field(INPB, "PPS:BSYS:1:ST34B:OUT_B MS") } record(bi, "PPS:BSYS:1:ST34B:OUT") { field(SCAN, "Passive") field(DESC, "ST34B OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "PPS:BSYS:1:ST34B:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:ST34:PERMITTEDCALC") { field(SCAN, ".1 second") field(DESC, "ST34 Set Permit Calc") field(FLNK, "PPS:BSYS:1:ST34:PERMITTED") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34:PERMITTED_A MS") field(INPB, "PPS:BSYS:1:ST34:PERMITTED_B MS") } record(bi, "PPS:BSYS:1:ST34:PERMITTED") { field(SCAN, "Passive") field(DESC, "ST34 Set Permit") field(DTYP, "Soft Channel") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(INP, "PPS:BSYS:1:ST34:PERMITTEDCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:STCLTS:INCALC") { field(SCAN, ".1 second") field(DESC, "STCLTS IN Sum Calc") field(FLNK, "PPS:BSYS:1:STCLTS:IN") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:STCLTS:IN_A MS") field(INPB, "PPS:BSYS:1:STCLTS:IN_B MS") } record(bi, "PPS:BSYS:1:STCLTS:IN") { field(SCAN, "Passive") field(DESC, "STCLTS IN Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_IN") field(ONAM, "IN") field(INP, "PPS:BSYS:1:STCLTS:INCALC MS") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(calc, "PPS:BSYS:1:STCLTS:OUTCALC") { field(SCAN, ".1 second") field(DESC, "STCLTS OUT Sum Calc") field(FLNK, "PPS:BSYS:1:STCLTS:OUT") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:STCLTS:OUT_A MS") field(INPB, "PPS:BSYS:1:STCLTS:OUT_B MS") } record(bi, "PPS:BSYS:1:STCLTS:OUT") { field(SCAN, "Passive") field(DESC, "STCLTS OUT Sum") field(DTYP, "Soft Channel") field(ZNAM, "NOT_OUT") field(ONAM, "OUT") field(INP, "PPS:BSYS:1:STCLTS:OUTCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:STCLTS:PERMITTEDCALC") { field(SCAN, ".1 second") field(DESC, "STCLTS Set Permit Calc") field(FLNK, "PPS:BSYS:1:STCLTS:PERMITTED") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:STCLTS:PERMITTED_A MS") field(INPB, "PPS:BSYS:1:STCLTS:PERMITTED_B MS") } record(bi, "PPS:BSYS:1:STCLTS:PERMITTED") { field(SCAN, "Passive") field(DESC, "STCLTS Set Permit") field(DTYP, "Soft Channel") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(INP, "PPS:BSYS:1:STCLTS:PERMITTEDCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:PLC5:STP_ENABLECALC") { field(SCAN, ".1 second") field(DESC, "Local ST34 Stopper Enable Calc") field(FLNK, "PPS:BSYS:1:PLC5:STP_ENABLE") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:PLC5:STP_ENABLE_A MS") field(INPB, "PPS:BSYS:1:PLC5:STP_ENABLE_B MS") } record(bi, "PPS:BSYS:1:PLC5:STP_ENABLE") { field(SCAN, "Passive") field(DESC, "Local ST34 Stopper Enable") field(DTYP, "Soft Channel") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(INP, "PPS:BSYS:1:PLC5:STP_ENABLECALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:PLC5:STP_ENABLE_LATCALC") { field(SCAN, ".1 second") field(DESC, "Local ST34 Stopper Enable Calc") field(FLNK, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_A MS") field(INPB, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT_B MS") } record(bi, "PPS:BSYS:1:PLC5:STP_ENABLE_LAT") { field(SCAN, "Passive") field(DESC, "Local ST34 Stopper Enable") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "PPS:BSYS:1:PLC5:STP_ENABLE_LATCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:ST34:ADMIN_ENCALC") { field(SCAN, ".1 second") field(DESC, "ST34:Enable_Keysw_Calc") field(FLNK, "PPS:BSYS:1:ST34:ADMIN_EN") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34:ADMIN_EN_A MS") field(INPB, "PPS:BSYS:1:ST34:ADMIN_EN_B MS") } record(bi, "PPS:BSYS:1:ST34:ADMIN_EN") { field(SCAN, "Passive") field(DESC, "ST34:Enable_Keysw") field(DTYP, "Soft Channel") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(INP, "PPS:BSYS:1:ST34:ADMIN_ENCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSYS:1:ST34:ADMIN_EN_LTHCALC") { field(SCAN, ".1 second") field(DESC, "ACR_ST34:Enable_Keysw_Calc") field(FLNK, "PPS:BSYS:1:ST34:ADMIN_EN_LTH") field(CALC, "A&&B") field(INPA, "PPS:BSYS:1:ST34:ADMIN_EN_LTH_A MS") field(INPB, "PPS:BSYS:1:ST34:ADMIN_EN_LTH_B MS") } record(bi, "PPS:BSYS:1:ST34:ADMIN_EN_LTH") { field(SCAN, "Passive") field(DESC, "ACR_ST34:Enable_Keysw") field(DTYP, "Soft Channel") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(INP, "PPS:BSYS:1:ST34:ADMIN_EN_LTHCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(calc, "PPS:BSY0:1:EMEROFF_SUMCALC") { field(SCAN, ".1 second") field(DESC, "E/O summary calculation") field(FLNK, "PPS:BSY0:1:EMEROFF_SUM") field(CALC, "(A+B+C+D+E+F+G+H+I+J+K+L)>0?0:1") field(INPA, "PPS:BSY0:1:SIT:EMEROFF_LTH.SEVR MS") field(INPB, "PPS:BSY0:1:NIT:EMEROFF_LTH.SEVR MS") field(INPC, "PPS:BSY0:1:SARC:EMEROFF_LTH.SEVR MS") field(INPD, "PPS:BSY0:1:NARC:EMEROFF_LTH.SEVR MS") field(INPE, "PPS:BSY0:1:WEST:EMEROFF_LTH.SEVR MS") field(INPF, "PPS:BSY0:2:WEST:EMEROFF_LTH.SEVR MS") field(INPG, "PPS:BSY0:1:MAINACC:EMEROFF_LTH.SEVR MS") field(INPH, "PPS:BSY0:1:CW2:EMEROFF_LTH.SEVR MS") field(INPI, "PPS:BSY0:3:EAST:EMEROFF_LTH.SEVR MS") field(INPJ, "PPS:BSY0:1:EAST:EMEROFF_LTH.SEVR MS") field(INPK, "PPS:BSY0:2:EAST:EMEROFF_LTH.SEVR MS") field(INPL, "PPS:BSY0:1:CW4:EMEROFF_LTH.SEVR MS") } record(bi, "PPS:BSY0:1:EMEROFF_SUM") { field(SCAN, "Passive") field(DESC, "E/O summary") field(DTYP, "Soft Channel") field(ZNAM, "Fault") field(ONAM, "OK") field(INP, "PPS:BSY0:1:EMEROFF_SUMCALC MS") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # Converts the search timer seconds into minutes record(calc, "PPS:BSY0:1:SEARCHTIMER_MIN_CALC") { field(SCAN, "1 second") field(DESC, "Search timer in minutes") field(EGU, "Minutes") field(CALC, "A/60") field(INPA, "PPS:BSY0:1:SEARCHTIMER_MIN NPP NMS") } # ALH bypass mode for BSY BSOICs at BTH boundary gate record(calcout, "BSOC:BSY0:1:CALCMODE") { field(SCAN, "2 second") field(CALC, "A") field(INPA, "PPS:UND0:1:LOOPLAT CPP") field(OUT, "BSOC:BSY0:1:MODE PP") field(OOPT, "Every Time") } record(bi, "BSOC:BSY0:1:MODE") { field(DESC, "BTH boundary BSOIC bypass mode") field(OSV, "MINOR") field(ZNAM, "ACTIVE") field(ONAM, "BYPASS") field(PINI, "YES") }