#! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi7") { field(DESC, "Port LI08_BSOIC_Rd bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BSOC:LI08:1:HwEn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:HwEn_calc") { field(INPA, "PLC:LI08:PP02:Bi7 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:HwEn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:HwEn") { field(DESC, "BSOIC-HW_Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb7",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb7") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb7.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb7.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb7.FLNK","BSOC:LI08:1:HwEn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb7.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb7.VAL") #! Record("BSOC:LI08:1:HwEn_calc",260,18,0,1,"BSOC:LI08:1:HwEn_calc") #! Field("BSOC:LI08:1:HwEn_calc.INPA",16777215,0,"BSOC:LI08:1:HwEn_calc.INPA") #! Link("BSOC:LI08:1:HwEn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb7.VAL") #! Field("BSOC:LI08:1:HwEn_calc.INPB",16777215,1,"BSOC:LI08:1:HwEn_calc.INPB") #! Field("BSOC:LI08:1:HwEn_calc.OUT",16777215,1,"BSOC:LI08:1:HwEn_calc.OUT") #! Link("BSOC:LI08:1:HwEn_calc.OUT","BSOC:LI08:1:HwEn.VAL") #! Record("BSOC:LI08:1:HwEn",500,20,0,0,"BSOC:LI08:1:HwEn") #! Field("BSOC:LI08:1:HwEn.VAL",16777215,1,"BSOC:LI08:1:HwEn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi6") { field(DESC, "Port LI08_BSOIC_Rd bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI08:1:HwResetAll_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:HwResetAll_calc") { field(INPA, "PLC:LI08:PP02:Bi6 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:HwResetAll PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:HwResetAll") { field(DESC, "BSOIC-HW_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb6",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb6") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb6.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb6.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb6.FLNK","BSOC:LI08:1:HwResetAll_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb6.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb6.VAL") #! Record("BSOC:LI08:1:HwResetAll_calc",260,18,0,1,"BSOC:LI08:1:HwResetAll_calc") #! Field("BSOC:LI08:1:HwResetAll_calc.INPA",16777215,0,"BSOC:LI08:1:HwResetAll_calc.INPA") #! Link("BSOC:LI08:1:HwResetAll_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb6.VAL") #! Field("BSOC:LI08:1:HwResetAll_calc.INPB",16777215,1,"BSOC:LI08:1:HwResetAll_calc.INPB") #! Field("BSOC:LI08:1:HwResetAll_calc.OUT",16777215,1,"BSOC:LI08:1:HwResetAll_calc.OUT") #! Link("BSOC:LI08:1:HwResetAll_calc.OUT","BSOC:LI08:1:HwResetAll.VAL") #! Record("BSOC:LI08:1:HwResetAll",500,20,0,0,"BSOC:LI08:1:HwResetAll") #! Field("BSOC:LI08:1:HwResetAll.VAL",16777215,1,"BSOC:LI08:1:HwResetAll.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi5") { field(DESC, "Port LI08_BSOIC_Rd bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI10:12:Eqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:Eqp_calc") { field(INPA, "PLC:LI08:PP02:Bi5 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:Eqp") { field(DESC, "BSOIC-RT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb5",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb5") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb5.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb5.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb5.FLNK","BSOC:LI10:12:Eqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb5.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb5.VAL") #! Record("BSOC:LI10:12:Eqp_calc",260,18,0,1,"BSOC:LI10:12:Eqp_calc") #! Field("BSOC:LI10:12:Eqp_calc.INPA",16777215,0,"BSOC:LI10:12:Eqp_calc.INPA") #! Link("BSOC:LI10:12:Eqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb5.VAL") #! Field("BSOC:LI10:12:Eqp_calc.INPB",16777215,1,"BSOC:LI10:12:Eqp_calc.INPB") #! Field("BSOC:LI10:12:Eqp_calc.OUT",16777215,1,"BSOC:LI10:12:Eqp_calc.OUT") #! Link("BSOC:LI10:12:Eqp_calc.OUT","BSOC:LI10:12:Eqp.VAL") #! Record("BSOC:LI10:12:Eqp",500,20,0,0,"BSOC:LI10:12:Eqp") #! Field("BSOC:LI10:12:Eqp.VAL",16777215,1,"BSOC:LI10:12:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi4") { field(DESC, "Port LI08_BSOIC_Rd bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 4, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI10:12:Rad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:Rad_calc") { field(INPA, "PLC:LI08:PP02:Bi4 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:Rad") { field(DESC, "BSOIC-RT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb4",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb4") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb4.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb4.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb4.FLNK","BSOC:LI10:12:Rad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb4.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb4.VAL") #! Record("BSOC:LI10:12:Rad_calc",260,18,0,1,"BSOC:LI10:12:Rad_calc") #! Field("BSOC:LI10:12:Rad_calc.INPA",16777215,0,"BSOC:LI10:12:Rad_calc.INPA") #! Link("BSOC:LI10:12:Rad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb4.VAL") #! Field("BSOC:LI10:12:Rad_calc.INPB",16777215,1,"BSOC:LI10:12:Rad_calc.INPB") #! Field("BSOC:LI10:12:Rad_calc.OUT",16777215,1,"BSOC:LI10:12:Rad_calc.OUT") #! Link("BSOC:LI10:12:Rad_calc.OUT","BSOC:LI10:12:Rad.VAL") #! Record("BSOC:LI10:12:Rad",500,20,0,0,"BSOC:LI10:12:Rad") #! Field("BSOC:LI10:12:Rad.VAL",16777215,1,"BSOC:LI10:12:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi3") { field(DESC, "Port LI08_BSOIC_Rd bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI10:12:HWBypass_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:HWBypass_calc") { field(INPA, "PLC:LI08:PP02:Bi3 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:HWBypass") { field(DESC, "BSOIC-RT_G1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb3",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb3") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb3.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb3.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb3.FLNK","BSOC:LI10:12:HWBypass_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb3.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb3.VAL") #! Record("BSOC:LI10:12:HWBypass_calc",260,18,0,1,"BSOC:LI10:12:HWBypass_calc") #! Field("BSOC:LI10:12:HWBypass_calc.INPA",16777215,0,"BSOC:LI10:12:HWBypass_calc.INPA") #! Link("BSOC:LI10:12:HWBypass_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb3.VAL") #! Field("BSOC:LI10:12:HWBypass_calc.INPB",16777215,1,"BSOC:LI10:12:HWBypass_calc.INPB") #! Field("BSOC:LI10:12:HWBypass_calc.OUT",16777215,1,"BSOC:LI10:12:HWBypass_calc.OUT") #! Link("BSOC:LI10:12:HWBypass_calc.OUT","BSOC:LI10:12:HWBypass.VAL") #! Record("BSOC:LI10:12:HWBypass",500,20,0,0,"BSOC:LI10:12:HWBypass") #! Field("BSOC:LI10:12:HWBypass.VAL",16777215,1,"BSOC:LI10:12:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi2") { field(DESC, "Port LI08_BSOIC_Rd bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:IN10:03:Eqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:Eqp_calc") { field(INPA, "PLC:LI08:PP02:Bi2 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:Eqp") { field(DESC, "BSOIC-RT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb2",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb2") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb2.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb2.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb2.FLNK","BSOC:IN10:03:Eqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb2.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb2.VAL") #! Record("BSOC:IN10:03:Eqp_calc",260,18,0,1,"BSOC:IN10:03:Eqp_calc") #! Field("BSOC:IN10:03:Eqp_calc.INPA",16777215,0,"BSOC:IN10:03:Eqp_calc.INPA") #! Link("BSOC:IN10:03:Eqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb2.VAL") #! Field("BSOC:IN10:03:Eqp_calc.INPB",16777215,1,"BSOC:IN10:03:Eqp_calc.INPB") #! Field("BSOC:IN10:03:Eqp_calc.OUT",16777215,1,"BSOC:IN10:03:Eqp_calc.OUT") #! Link("BSOC:IN10:03:Eqp_calc.OUT","BSOC:IN10:03:Eqp.VAL") #! Record("BSOC:IN10:03:Eqp",500,20,0,0,"BSOC:IN10:03:Eqp") #! Field("BSOC:IN10:03:Eqp.VAL",16777215,1,"BSOC:IN10:03:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi1") { field(DESC, "Port LI08_BSOIC_Rd bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:IN10:03:Rad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:Rad_calc") { field(INPA, "PLC:LI08:PP02:Bi1 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:Rad") { field(DESC, "BSOIC-RT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb1",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb1") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb1.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb1.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb1.FLNK","BSOC:IN10:03:Rad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb1.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb1.VAL") #! Record("BSOC:IN10:03:Rad_calc",260,18,0,1,"BSOC:IN10:03:Rad_calc") #! Field("BSOC:IN10:03:Rad_calc.INPA",16777215,0,"BSOC:IN10:03:Rad_calc.INPA") #! Link("BSOC:IN10:03:Rad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb1.VAL") #! Field("BSOC:IN10:03:Rad_calc.INPB",16777215,1,"BSOC:IN10:03:Rad_calc.INPB") #! Field("BSOC:IN10:03:Rad_calc.OUT",16777215,1,"BSOC:IN10:03:Rad_calc.OUT") #! Link("BSOC:IN10:03:Rad_calc.OUT","BSOC:IN10:03:Rad.VAL") #! Record("BSOC:IN10:03:Rad",500,20,0,0,"BSOC:IN10:03:Rad") #! Field("BSOC:IN10:03:Rad.VAL",16777215,1,"BSOC:IN10:03:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi0") { field(DESC, "Port LI08_BSOIC_Rd bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:IN10:03:HWBypass_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:HWBypass_calc") { field(INPA, "PLC:LI08:PP02:Bi0 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:HWBypass") { field(DESC, "BSOIC-RT_G2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb0",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb0") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb0.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb0.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb0.FLNK","BSOC:IN10:03:HWBypass_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb0.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb0.VAL") #! Record("BSOC:IN10:03:HWBypass_calc",260,18,0,1,"BSOC:IN10:03:HWBypass_calc") #! Field("BSOC:IN10:03:HWBypass_calc.INPA",16777215,0,"BSOC:IN10:03:HWBypass_calc.INPA") #! Link("BSOC:IN10:03:HWBypass_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb0.VAL") #! Field("BSOC:IN10:03:HWBypass_calc.INPB",16777215,1,"BSOC:IN10:03:HWBypass_calc.INPB") #! Field("BSOC:IN10:03:HWBypass_calc.OUT",16777215,1,"BSOC:IN10:03:HWBypass_calc.OUT") #! Link("BSOC:IN10:03:HWBypass_calc.OUT","BSOC:IN10:03:HWBypass.VAL") #! Record("BSOC:IN10:03:HWBypass",500,20,0,0,"BSOC:IN10:03:HWBypass") #! Field("BSOC:IN10:03:HWBypass.VAL",16777215,1,"BSOC:IN10:03:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi15") { field(DESC, "Port LI08_BSOIC_Rd bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G3:Eqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:Eqp_calc") { field(INPA, "PLC:LI08:PP02:Bi15 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:Eqp") { field(DESC, "BSOIC-RT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb15",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb15") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb15.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb15.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb15.FLNK","BSOC:LI08:G3:Eqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb15.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb15.VAL") #! Record("BSOC:LI08:G3:Eqp_calc",260,18,0,1,"BSOC:LI08:G3:Eqp_calc") #! Field("BSOC:LI08:G3:Eqp_calc.INPA",16777215,0,"BSOC:LI08:G3:Eqp_calc.INPA") #! Link("BSOC:LI08:G3:Eqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb15.VAL") #! Field("BSOC:LI08:G3:Eqp_calc.INPB",16777215,1,"BSOC:LI08:G3:Eqp_calc.INPB") #! Field("BSOC:LI08:G3:Eqp_calc.OUT",16777215,1,"BSOC:LI08:G3:Eqp_calc.OUT") #! Link("BSOC:LI08:G3:Eqp_calc.OUT","BSOC:LI08:G3:Eqp.VAL") #! Record("BSOC:LI08:G3:Eqp",500,20,0,0,"BSOC:LI08:G3:Eqp") #! Field("BSOC:LI08:G3:Eqp.VAL",16777215,1,"BSOC:LI08:G3:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi14") { field(DESC, "Port LI08_BSOIC_Rd bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G3:Rad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:Rad_calc") { field(INPA, "PLC:LI08:PP02:Bi14 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:Rad") { field(DESC, "BSOIC-RT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb14",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb14") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb14.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb14.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb14.FLNK","BSOC:LI08:G3:Rad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb14.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb14.VAL") #! Record("BSOC:LI08:G3:Rad_calc",260,18,0,1,"BSOC:LI08:G3:Rad_calc") #! Field("BSOC:LI08:G3:Rad_calc.INPA",16777215,0,"BSOC:LI08:G3:Rad_calc.INPA") #! Link("BSOC:LI08:G3:Rad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb14.VAL") #! Field("BSOC:LI08:G3:Rad_calc.INPB",16777215,1,"BSOC:LI08:G3:Rad_calc.INPB") #! Field("BSOC:LI08:G3:Rad_calc.OUT",16777215,1,"BSOC:LI08:G3:Rad_calc.OUT") #! Link("BSOC:LI08:G3:Rad_calc.OUT","BSOC:LI08:G3:Rad.VAL") #! Record("BSOC:LI08:G3:Rad",500,20,0,0,"BSOC:LI08:G3:Rad") #! Field("BSOC:LI08:G3:Rad.VAL",16777215,1,"BSOC:LI08:G3:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi13") { field(DESC, "Port LI08_BSOIC_Rd bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 13, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI08:G3:HWBypass_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:HWBypass_calc") { field(INPA, "PLC:LI08:PP02:Bi13 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:HWBypass") { field(DESC, "BSOIC-RT_G3_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb13",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb13") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb13.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb13.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb13.FLNK","BSOC:LI08:G3:HWBypass_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb13.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb13.VAL") #! Record("BSOC:LI08:G3:HWBypass_calc",260,18,0,1,"BSOC:LI08:G3:HWBypass_calc") #! Field("BSOC:LI08:G3:HWBypass_calc.INPA",16777215,0,"BSOC:LI08:G3:HWBypass_calc.INPA") #! Link("BSOC:LI08:G3:HWBypass_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb13.VAL") #! Field("BSOC:LI08:G3:HWBypass_calc.INPB",16777215,1,"BSOC:LI08:G3:HWBypass_calc.INPB") #! Field("BSOC:LI08:G3:HWBypass_calc.OUT",16777215,1,"BSOC:LI08:G3:HWBypass_calc.OUT") #! Link("BSOC:LI08:G3:HWBypass_calc.OUT","BSOC:LI08:G3:HWBypass.VAL") #! Record("BSOC:LI08:G3:HWBypass",500,20,0,0,"BSOC:LI08:G3:HWBypass") #! Field("BSOC:LI08:G3:HWBypass.VAL",16777215,1,"BSOC:LI08:G3:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi12") { field(DESC, "Port LI08_BSOIC_Rd bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G4:Eqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:Eqp_calc") { field(INPA, "PLC:LI08:PP02:Bi12 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:Eqp") { field(DESC, "BSOIC-RT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb12",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb12") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb12.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb12.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb12.FLNK","BSOC:LI08:G4:Eqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb12.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb12.VAL") #! Record("BSOC:LI08:G4:Eqp_calc",260,18,0,1,"BSOC:LI08:G4:Eqp_calc") #! Field("BSOC:LI08:G4:Eqp_calc.INPA",16777215,0,"BSOC:LI08:G4:Eqp_calc.INPA") #! Link("BSOC:LI08:G4:Eqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb12.VAL") #! Field("BSOC:LI08:G4:Eqp_calc.INPB",16777215,1,"BSOC:LI08:G4:Eqp_calc.INPB") #! Field("BSOC:LI08:G4:Eqp_calc.OUT",16777215,1,"BSOC:LI08:G4:Eqp_calc.OUT") #! Link("BSOC:LI08:G4:Eqp_calc.OUT","BSOC:LI08:G4:Eqp.VAL") #! Record("BSOC:LI08:G4:Eqp",500,20,0,0,"BSOC:LI08:G4:Eqp") #! Field("BSOC:LI08:G4:Eqp.VAL",16777215,1,"BSOC:LI08:G4:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi11") { field(DESC, "Port LI08_BSOIC_Rd bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G4:Rad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:Rad_calc") { field(INPA, "PLC:LI08:PP02:Bi11 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:Rad") { field(DESC, "BSOIC-RT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb11",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb11") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb11.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb11.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb11.FLNK","BSOC:LI08:G4:Rad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb11.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb11.VAL") #! Record("BSOC:LI08:G4:Rad_calc",260,18,0,1,"BSOC:LI08:G4:Rad_calc") #! Field("BSOC:LI08:G4:Rad_calc.INPA",16777215,0,"BSOC:LI08:G4:Rad_calc.INPA") #! Link("BSOC:LI08:G4:Rad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb11.VAL") #! Field("BSOC:LI08:G4:Rad_calc.INPB",16777215,1,"BSOC:LI08:G4:Rad_calc.INPB") #! Field("BSOC:LI08:G4:Rad_calc.OUT",16777215,1,"BSOC:LI08:G4:Rad_calc.OUT") #! Link("BSOC:LI08:G4:Rad_calc.OUT","BSOC:LI08:G4:Rad.VAL") #! Record("BSOC:LI08:G4:Rad",500,20,0,0,"BSOC:LI08:G4:Rad") #! Field("BSOC:LI08:G4:Rad.VAL",16777215,1,"BSOC:LI08:G4:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi10") { field(DESC, "Port LI08_BSOIC_Rd bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 10, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI08:G4:HWBypass_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:HWBypass_calc") { field(INPA, "PLC:LI08:PP02:Bi10 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:HWBypass") { field(DESC, "BSOIC-RT_G4_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb10",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb10") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb10.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb10.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb10.FLNK","BSOC:LI08:G4:HWBypass_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb10.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb10.VAL") #! Record("BSOC:LI08:G4:HWBypass_calc",260,18,0,1,"BSOC:LI08:G4:HWBypass_calc") #! Field("BSOC:LI08:G4:HWBypass_calc.INPA",16777215,0,"BSOC:LI08:G4:HWBypass_calc.INPA") #! Link("BSOC:LI08:G4:HWBypass_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb10.VAL") #! Field("BSOC:LI08:G4:HWBypass_calc.INPB",16777215,1,"BSOC:LI08:G4:HWBypass_calc.INPB") #! Field("BSOC:LI08:G4:HWBypass_calc.OUT",16777215,1,"BSOC:LI08:G4:HWBypass_calc.OUT") #! Link("BSOC:LI08:G4:HWBypass_calc.OUT","BSOC:LI08:G4:HWBypass.VAL") #! Record("BSOC:LI08:G4:HWBypass",500,20,0,0,"BSOC:LI08:G4:HWBypass") #! Field("BSOC:LI08:G4:HWBypass.VAL",16777215,1,"BSOC:LI08:G4:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi9") { field(DESC, "Port LI08_BSOIC_Rd bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:N1:Rad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N1:Rad_calc") { field(INPA, "PLC:LI08:PP02:Bi9 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N1:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N1:Rad") { field(DESC, "BSOIC-RT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb9",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb9") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb9.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb9.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb9.FLNK","BSOC:LI08:N1:Rad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb9.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb9.VAL") #! Record("BSOC:LI08:N1:Rad_calc",260,18,0,1,"BSOC:LI08:N1:Rad_calc") #! Field("BSOC:LI08:N1:Rad_calc.INPA",16777215,0,"BSOC:LI08:N1:Rad_calc.INPA") #! Link("BSOC:LI08:N1:Rad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb9.VAL") #! Field("BSOC:LI08:N1:Rad_calc.INPB",16777215,1,"BSOC:LI08:N1:Rad_calc.INPB") #! Field("BSOC:LI08:N1:Rad_calc.OUT",16777215,1,"BSOC:LI08:N1:Rad_calc.OUT") #! Link("BSOC:LI08:N1:Rad_calc.OUT","BSOC:LI08:N1:Rad.VAL") #! Record("BSOC:LI08:N1:Rad",500,20,0,0,"BSOC:LI08:N1:Rad") #! Field("BSOC:LI08:N1:Rad.VAL",16777215,1,"BSOC:LI08:N1:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi8") { field(DESC, "Port LI08_BSOIC_Rd bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 8, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI08:N1:HWBypass_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N1:HWBypass_calc") { field(INPA, "PLC:LI08:PP02:Bi8 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N1:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N1:HWBypass") { field(DESC, "BSOIC-RT_N1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb8",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb8") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb8.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb8.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb8.FLNK","BSOC:LI08:N1:HWBypass_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb8.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb8.VAL") #! Record("BSOC:LI08:N1:HWBypass_calc",260,18,0,1,"BSOC:LI08:N1:HWBypass_calc") #! Field("BSOC:LI08:N1:HWBypass_calc.INPA",16777215,0,"BSOC:LI08:N1:HWBypass_calc.INPA") #! Link("BSOC:LI08:N1:HWBypass_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb8.VAL") #! Field("BSOC:LI08:N1:HWBypass_calc.INPB",16777215,1,"BSOC:LI08:N1:HWBypass_calc.INPB") #! Field("BSOC:LI08:N1:HWBypass_calc.OUT",16777215,1,"BSOC:LI08:N1:HWBypass_calc.OUT") #! Link("BSOC:LI08:N1:HWBypass_calc.OUT","BSOC:LI08:N1:HWBypass.VAL") #! Record("BSOC:LI08:N1:HWBypass",500,20,0,0,"BSOC:LI08:N1:HWBypass") #! Field("BSOC:LI08:N1:HWBypass.VAL",16777215,1,"BSOC:LI08:N1:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi23") { field(DESC, "Port LI08_BSOIC_Rd bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:N2:Rad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N2:Rad_calc") { field(INPA, "PLC:LI08:PP02:Bi23 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N2:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N2:Rad") { field(DESC, "BSOIC-RT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb23",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb23") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb23.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb23.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb23.FLNK","BSOC:LI08:N2:Rad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb23.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb23.VAL") #! Record("BSOC:LI08:N2:Rad_calc",260,18,0,1,"BSOC:LI08:N2:Rad_calc") #! Field("BSOC:LI08:N2:Rad_calc.INPA",16777215,0,"BSOC:LI08:N2:Rad_calc.INPA") #! Link("BSOC:LI08:N2:Rad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb23.VAL") #! Field("BSOC:LI08:N2:Rad_calc.INPB",16777215,1,"BSOC:LI08:N2:Rad_calc.INPB") #! Field("BSOC:LI08:N2:Rad_calc.OUT",16777215,1,"BSOC:LI08:N2:Rad_calc.OUT") #! Link("BSOC:LI08:N2:Rad_calc.OUT","BSOC:LI08:N2:Rad.VAL") #! Record("BSOC:LI08:N2:Rad",500,20,0,0,"BSOC:LI08:N2:Rad") #! Field("BSOC:LI08:N2:Rad.VAL",16777215,1,"BSOC:LI08:N2:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi22") { field(DESC, "Port LI08_BSOIC_Rd bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 22, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI08:N2:HWBypass_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N2:HWBypass_calc") { field(INPA, "PLC:LI08:PP02:Bi22 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N2:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N2:HWBypass") { field(DESC, "BSOIC-RT_N2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb22",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb22") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb22.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb22.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb22.FLNK","BSOC:LI08:N2:HWBypass_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb22.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb22.VAL") #! Record("BSOC:LI08:N2:HWBypass_calc",260,18,0,1,"BSOC:LI08:N2:HWBypass_calc") #! Field("BSOC:LI08:N2:HWBypass_calc.INPA",16777215,0,"BSOC:LI08:N2:HWBypass_calc.INPA") #! Link("BSOC:LI08:N2:HWBypass_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb22.VAL") #! Field("BSOC:LI08:N2:HWBypass_calc.INPB",16777215,1,"BSOC:LI08:N2:HWBypass_calc.INPB") #! Field("BSOC:LI08:N2:HWBypass_calc.OUT",16777215,1,"BSOC:LI08:N2:HWBypass_calc.OUT") #! Link("BSOC:LI08:N2:HWBypass_calc.OUT","BSOC:LI08:N2:HWBypass.VAL") #! Record("BSOC:LI08:N2:HWBypass",500,20,0,0,"BSOC:LI08:N2:HWBypass") #! Field("BSOC:LI08:N2:HWBypass.VAL",16777215,1,"BSOC:LI08:N2:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi21") { field(DESC, "Port LI08_BSOIC_Rd bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:CascIn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:CascIn_calc") { field(INPA, "PLC:LI08:PP02:Bi21 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb21",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb21") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb21.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb21.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb21.FLNK","BSOC:LI08:1:CascIn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb21.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb21.VAL") #! Record("BSOC:LI08:1:CascIn_calc",260,18,0,1,"BSOC:LI08:1:CascIn_calc") #! Field("BSOC:LI08:1:CascIn_calc.INPA",16777215,0,"BSOC:LI08:1:CascIn_calc.INPA") #! Link("BSOC:LI08:1:CascIn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb21.VAL") #! Field("BSOC:LI08:1:CascIn_calc.INPB",16777215,1,"BSOC:LI08:1:CascIn_calc.INPB") #! Field("BSOC:LI08:1:CascIn_calc.OUT",16777215,1,"BSOC:LI08:1:CascIn_calc.OUT") #! Link("BSOC:LI08:1:CascIn_calc.OUT","BSOC:LI08:1:CascIn.VAL") #! Record("BSOC:LI08:1:CascIn",500,20,0,0,"BSOC:LI08:1:CascIn") #! Field("BSOC:LI08:1:CascIn.VAL",16777215,1,"BSOC:LI08:1:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi20") { field(DESC, "Port LI08_BSOIC_Rd bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:2:CascIn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:2:CascIn_calc") { field(INPA, "PLC:LI08:PP02:Bi20 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:2:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:2:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb20",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb20") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb20.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb20.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb20.FLNK","BSOC:LI08:2:CascIn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb20.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb20.VAL") #! Record("BSOC:LI08:2:CascIn_calc",260,18,0,1,"BSOC:LI08:2:CascIn_calc") #! Field("BSOC:LI08:2:CascIn_calc.INPA",16777215,0,"BSOC:LI08:2:CascIn_calc.INPA") #! Link("BSOC:LI08:2:CascIn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb20.VAL") #! Field("BSOC:LI08:2:CascIn_calc.INPB",16777215,1,"BSOC:LI08:2:CascIn_calc.INPB") #! Field("BSOC:LI08:2:CascIn_calc.OUT",16777215,1,"BSOC:LI08:2:CascIn_calc.OUT") #! Link("BSOC:LI08:2:CascIn_calc.OUT","BSOC:LI08:2:CascIn.VAL") #! Record("BSOC:LI08:2:CascIn",500,20,0,0,"BSOC:LI08:2:CascIn") #! Field("BSOC:LI08:2:CascIn.VAL",16777215,1,"BSOC:LI08:2:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi19") { field(DESC, "Port LI08_BSOIC_Rd bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 19, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI10:12:SoRstRb_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:SoRstRb_calc") { field(INPA, "PLC:LI08:PP02:Bi19 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:SoRstRb") { field(DESC, "BSOIC-G1_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb19",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb19") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb19.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb19.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb19.FLNK","BSOC:LI10:12:SoRstRb_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb19.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb19.VAL") #! Record("BSOC:LI10:12:SoRstRb_calc",260,18,0,1,"BSOC:LI10:12:SoRstRb_calc") #! Field("BSOC:LI10:12:SoRstRb_calc.INPA",16777215,0,"BSOC:LI10:12:SoRstRb_calc.INPA") #! Link("BSOC:LI10:12:SoRstRb_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb19.VAL") #! Field("BSOC:LI10:12:SoRstRb_calc.INPB",16777215,1,"BSOC:LI10:12:SoRstRb_calc.INPB") #! Field("BSOC:LI10:12:SoRstRb_calc.OUT",16777215,1,"BSOC:LI10:12:SoRstRb_calc.OUT") #! Link("BSOC:LI10:12:SoRstRb_calc.OUT","BSOC:LI10:12:SoRstRb.VAL") #! Record("BSOC:LI10:12:SoRstRb",500,20,0,0,"BSOC:LI10:12:SoRstRb") #! Field("BSOC:LI10:12:SoRstRb.VAL",16777215,1,"BSOC:LI10:12:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi18") { field(DESC, "Port LI08_BSOIC_Rd bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 18, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:IN10:03:SoRstRb_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:SoRstRb_calc") { field(INPA, "PLC:LI08:PP02:Bi18 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:SoRstRb") { field(DESC, "BSOIC-G2_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb18",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb18") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb18.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb18.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb18.FLNK","BSOC:IN10:03:SoRstRb_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb18.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb18.VAL") #! Record("BSOC:IN10:03:SoRstRb_calc",260,18,0,1,"BSOC:IN10:03:SoRstRb_calc") #! Field("BSOC:IN10:03:SoRstRb_calc.INPA",16777215,0,"BSOC:IN10:03:SoRstRb_calc.INPA") #! Link("BSOC:IN10:03:SoRstRb_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb18.VAL") #! Field("BSOC:IN10:03:SoRstRb_calc.INPB",16777215,1,"BSOC:IN10:03:SoRstRb_calc.INPB") #! Field("BSOC:IN10:03:SoRstRb_calc.OUT",16777215,1,"BSOC:IN10:03:SoRstRb_calc.OUT") #! Link("BSOC:IN10:03:SoRstRb_calc.OUT","BSOC:IN10:03:SoRstRb.VAL") #! Record("BSOC:IN10:03:SoRstRb",500,20,0,0,"BSOC:IN10:03:SoRstRb") #! Field("BSOC:IN10:03:SoRstRb.VAL",16777215,1,"BSOC:IN10:03:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi17") { field(DESC, "Port LI08_BSOIC_Rd bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 17, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI08:G3:SoRstRb_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:SoRstRb_calc") { field(INPA, "PLC:LI08:PP02:Bi17 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:SoRstRb") { field(DESC, "BSOIC-G3_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb17",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb17") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb17.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb17.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb17.FLNK","BSOC:LI08:G3:SoRstRb_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb17.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb17.VAL") #! Record("BSOC:LI08:G3:SoRstRb_calc",260,18,0,1,"BSOC:LI08:G3:SoRstRb_calc") #! Field("BSOC:LI08:G3:SoRstRb_calc.INPA",16777215,0,"BSOC:LI08:G3:SoRstRb_calc.INPA") #! Link("BSOC:LI08:G3:SoRstRb_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb17.VAL") #! Field("BSOC:LI08:G3:SoRstRb_calc.INPB",16777215,1,"BSOC:LI08:G3:SoRstRb_calc.INPB") #! Field("BSOC:LI08:G3:SoRstRb_calc.OUT",16777215,1,"BSOC:LI08:G3:SoRstRb_calc.OUT") #! Link("BSOC:LI08:G3:SoRstRb_calc.OUT","BSOC:LI08:G3:SoRstRb.VAL") #! Record("BSOC:LI08:G3:SoRstRb",500,20,0,0,"BSOC:LI08:G3:SoRstRb") #! Field("BSOC:LI08:G3:SoRstRb.VAL",16777215,1,"BSOC:LI08:G3:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi16") { field(DESC, "Port LI08_BSOIC_Rd bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 16, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI08:G4:SoRstRb_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:SoRstRb_calc") { field(INPA, "PLC:LI08:PP02:Bi16 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:SoRstRb") { field(DESC, "BSOIC-G4_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb16",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb16") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb16.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb16.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb16.FLNK","BSOC:LI08:G4:SoRstRb_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb16.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb16.VAL") #! Record("BSOC:LI08:G4:SoRstRb_calc",260,18,0,1,"BSOC:LI08:G4:SoRstRb_calc") #! Field("BSOC:LI08:G4:SoRstRb_calc.INPA",16777215,0,"BSOC:LI08:G4:SoRstRb_calc.INPA") #! Link("BSOC:LI08:G4:SoRstRb_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb16.VAL") #! Field("BSOC:LI08:G4:SoRstRb_calc.INPB",16777215,1,"BSOC:LI08:G4:SoRstRb_calc.INPB") #! Field("BSOC:LI08:G4:SoRstRb_calc.OUT",16777215,1,"BSOC:LI08:G4:SoRstRb_calc.OUT") #! Link("BSOC:LI08:G4:SoRstRb_calc.OUT","BSOC:LI08:G4:SoRstRb.VAL") #! Record("BSOC:LI08:G4:SoRstRb",500,20,0,0,"BSOC:LI08:G4:SoRstRb") #! Field("BSOC:LI08:G4:SoRstRb.VAL",16777215,1,"BSOC:LI08:G4:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi95") { field(DESC, "Port LI08_BSOIC_Rd bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 95, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI08:1:AnnAlarm_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:AnnAlarm_calc") { field(INPA, "PLC:LI08:PP02:Bi95 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:AnnAlarm PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:AnnAlarm") { field(DESC, "BSOIC-HW_Annunciator_Alarm") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb95",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb95") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb95.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb95.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb95.FLNK","BSOC:LI08:1:AnnAlarm_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb95.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb95.VAL") #! Record("BSOC:LI08:1:AnnAlarm_calc",260,18,0,1,"BSOC:LI08:1:AnnAlarm_calc") #! Field("BSOC:LI08:1:AnnAlarm_calc.INPA",16777215,0,"BSOC:LI08:1:AnnAlarm_calc.INPA") #! Link("BSOC:LI08:1:AnnAlarm_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb95.VAL") #! Field("BSOC:LI08:1:AnnAlarm_calc.INPB",16777215,1,"BSOC:LI08:1:AnnAlarm_calc.INPB") #! Field("BSOC:LI08:1:AnnAlarm_calc.OUT",16777215,1,"BSOC:LI08:1:AnnAlarm_calc.OUT") #! Link("BSOC:LI08:1:AnnAlarm_calc.OUT","BSOC:LI08:1:AnnAlarm.VAL") #! Record("BSOC:LI08:1:AnnAlarm",500,20,0,0,"BSOC:LI08:1:AnnAlarm") #! Field("BSOC:LI08:1:AnnAlarm.VAL",16777215,1,"BSOC:LI08:1:AnnAlarm.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi94") { field(DESC, "Port LI08_BSOIC_Rd bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 94, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI08:1:CascOut_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:CascOut_calc") { field(INPA, "PLC:LI08:PP02:Bi94 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:CascOut PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:CascOut") { field(DESC, "BSOIC-HW_Cascade_Out") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb94",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb94") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb94.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb94.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb94.FLNK","BSOC:LI08:1:CascOut_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb94.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb94.VAL") #! Record("BSOC:LI08:1:CascOut_calc",260,18,0,1,"BSOC:LI08:1:CascOut_calc") #! Field("BSOC:LI08:1:CascOut_calc.INPA",16777215,0,"BSOC:LI08:1:CascOut_calc.INPA") #! Link("BSOC:LI08:1:CascOut_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb94.VAL") #! Field("BSOC:LI08:1:CascOut_calc.INPB",16777215,1,"BSOC:LI08:1:CascOut_calc.INPB") #! Field("BSOC:LI08:1:CascOut_calc.OUT",16777215,1,"BSOC:LI08:1:CascOut_calc.OUT") #! Link("BSOC:LI08:1:CascOut_calc.OUT","BSOC:LI08:1:CascOut.VAL") #! Record("BSOC:LI08:1:CascOut",500,20,0,0,"BSOC:LI08:1:CascOut") #! Field("BSOC:LI08:1:CascOut.VAL",16777215,1,"BSOC:LI08:1:CascOut.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi93") { field(DESC, "Port LI08_BSOIC_Rd bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:HWSfOut1_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:HWSfOut1_calc") { field(INPA, "PLC:LI08:PP02:Bi93 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:HWSfOut1 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:HWSfOut1") { field(DESC, "BSOIC-HW_Safety_Out1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb93",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb93") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb93.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb93.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb93.FLNK","BSOC:LI08:1:HWSfOut1_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb93.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb93.VAL") #! Record("BSOC:LI08:1:HWSfOut1_calc",260,18,0,1,"BSOC:LI08:1:HWSfOut1_calc") #! Field("BSOC:LI08:1:HWSfOut1_calc.INPA",16777215,0,"BSOC:LI08:1:HWSfOut1_calc.INPA") #! Link("BSOC:LI08:1:HWSfOut1_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb93.VAL") #! Field("BSOC:LI08:1:HWSfOut1_calc.INPB",16777215,1,"BSOC:LI08:1:HWSfOut1_calc.INPB") #! Field("BSOC:LI08:1:HWSfOut1_calc.OUT",16777215,1,"BSOC:LI08:1:HWSfOut1_calc.OUT") #! Link("BSOC:LI08:1:HWSfOut1_calc.OUT","BSOC:LI08:1:HWSfOut1.VAL") #! Record("BSOC:LI08:1:HWSfOut1",500,20,0,0,"BSOC:LI08:1:HWSfOut1") #! Field("BSOC:LI08:1:HWSfOut1.VAL",16777215,1,"BSOC:LI08:1:HWSfOut1.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi92") { field(DESC, "Port LI08_BSOIC_Rd bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:HWSfOut2_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:HWSfOut2_calc") { field(INPA, "PLC:LI08:PP02:Bi92 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:HWSfOut2 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:HWSfOut2") { field(DESC, "BSOIC-HW_Safety_Out2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb92",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb92") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb92.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb92.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb92.FLNK","BSOC:LI08:1:HWSfOut2_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb92.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb92.VAL") #! Record("BSOC:LI08:1:HWSfOut2_calc",260,18,0,1,"BSOC:LI08:1:HWSfOut2_calc") #! Field("BSOC:LI08:1:HWSfOut2_calc.INPA",16777215,0,"BSOC:LI08:1:HWSfOut2_calc.INPA") #! Link("BSOC:LI08:1:HWSfOut2_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb92.VAL") #! Field("BSOC:LI08:1:HWSfOut2_calc.INPB",16777215,1,"BSOC:LI08:1:HWSfOut2_calc.INPB") #! Field("BSOC:LI08:1:HWSfOut2_calc.OUT",16777215,1,"BSOC:LI08:1:HWSfOut2_calc.OUT") #! Link("BSOC:LI08:1:HWSfOut2_calc.OUT","BSOC:LI08:1:HWSfOut2.VAL") #! Record("BSOC:LI08:1:HWSfOut2",500,20,0,0,"BSOC:LI08:1:HWSfOut2") #! Field("BSOC:LI08:1:HWSfOut2.VAL",16777215,1,"BSOC:LI08:1:HWSfOut2.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi91") { field(DESC, "Port LI08_BSOIC_Rd bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:HWSfOut3_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:HWSfOut3_calc") { field(INPA, "PLC:LI08:PP02:Bi91 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:HWSfOut3 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:HWSfOut3") { field(DESC, "BSOIC-HW_Safety_Out3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb91",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb91") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb91.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb91.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb91.FLNK","BSOC:LI08:1:HWSfOut3_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb91.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb91.VAL") #! Record("BSOC:LI08:1:HWSfOut3_calc",260,18,0,1,"BSOC:LI08:1:HWSfOut3_calc") #! Field("BSOC:LI08:1:HWSfOut3_calc.INPA",16777215,0,"BSOC:LI08:1:HWSfOut3_calc.INPA") #! Link("BSOC:LI08:1:HWSfOut3_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb91.VAL") #! Field("BSOC:LI08:1:HWSfOut3_calc.INPB",16777215,1,"BSOC:LI08:1:HWSfOut3_calc.INPB") #! Field("BSOC:LI08:1:HWSfOut3_calc.OUT",16777215,1,"BSOC:LI08:1:HWSfOut3_calc.OUT") #! Link("BSOC:LI08:1:HWSfOut3_calc.OUT","BSOC:LI08:1:HWSfOut3.VAL") #! Record("BSOC:LI08:1:HWSfOut3",500,20,0,0,"BSOC:LI08:1:HWSfOut3") #! Field("BSOC:LI08:1:HWSfOut3.VAL",16777215,1,"BSOC:LI08:1:HWSfOut3.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi90") { field(DESC, "Port LI08_BSOIC_Rd bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:HWSfOut4_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:HWSfOut4_calc") { field(INPA, "PLC:LI08:PP02:Bi90 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:HWSfOut4 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:HWSfOut4") { field(DESC, "BSOIC-HW_Safety_Out4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb90",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb90") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb90.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb90.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb90.FLNK","BSOC:LI08:1:HWSfOut4_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb90.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb90.VAL") #! Record("BSOC:LI08:1:HWSfOut4_calc",260,18,0,1,"BSOC:LI08:1:HWSfOut4_calc") #! Field("BSOC:LI08:1:HWSfOut4_calc.INPA",16777215,0,"BSOC:LI08:1:HWSfOut4_calc.INPA") #! Link("BSOC:LI08:1:HWSfOut4_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb90.VAL") #! Field("BSOC:LI08:1:HWSfOut4_calc.INPB",16777215,1,"BSOC:LI08:1:HWSfOut4_calc.INPB") #! Field("BSOC:LI08:1:HWSfOut4_calc.OUT",16777215,1,"BSOC:LI08:1:HWSfOut4_calc.OUT") #! Link("BSOC:LI08:1:HWSfOut4_calc.OUT","BSOC:LI08:1:HWSfOut4.VAL") #! Record("BSOC:LI08:1:HWSfOut4",500,20,0,0,"BSOC:LI08:1:HWSfOut4") #! Field("BSOC:LI08:1:HWSfOut4.VAL",16777215,1,"BSOC:LI08:1:HWSfOut4.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi89") { field(DESC, "Port LI08_BSOIC_Rd bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI10:12:LatEqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:LatEqp_calc") { field(INPA, "PLC:LI08:PP02:Bi89 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:LatEqp") { field(DESC, "BSOIC-LAT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb89",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb89") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb89.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb89.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb89.FLNK","BSOC:LI10:12:LatEqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb89.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb89.VAL") #! Record("BSOC:LI10:12:LatEqp_calc",260,18,0,1,"BSOC:LI10:12:LatEqp_calc") #! Field("BSOC:LI10:12:LatEqp_calc.INPA",16777215,0,"BSOC:LI10:12:LatEqp_calc.INPA") #! Link("BSOC:LI10:12:LatEqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb89.VAL") #! Field("BSOC:LI10:12:LatEqp_calc.INPB",16777215,1,"BSOC:LI10:12:LatEqp_calc.INPB") #! Field("BSOC:LI10:12:LatEqp_calc.OUT",16777215,1,"BSOC:LI10:12:LatEqp_calc.OUT") #! Link("BSOC:LI10:12:LatEqp_calc.OUT","BSOC:LI10:12:LatEqp.VAL") #! Record("BSOC:LI10:12:LatEqp",500,20,0,0,"BSOC:LI10:12:LatEqp") #! Field("BSOC:LI10:12:LatEqp.VAL",16777215,1,"BSOC:LI10:12:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi88") { field(DESC, "Port LI08_BSOIC_Rd bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI10:12:LatRad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:LatRad_calc") { field(INPA, "PLC:LI08:PP02:Bi88 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:LatRad") { field(DESC, "BSOIC-LAT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb88",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb88") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb88.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb88.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb88.FLNK","BSOC:LI10:12:LatRad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb88.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb88.VAL") #! Record("BSOC:LI10:12:LatRad_calc",260,18,0,1,"BSOC:LI10:12:LatRad_calc") #! Field("BSOC:LI10:12:LatRad_calc.INPA",16777215,0,"BSOC:LI10:12:LatRad_calc.INPA") #! Link("BSOC:LI10:12:LatRad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb88.VAL") #! Field("BSOC:LI10:12:LatRad_calc.INPB",16777215,1,"BSOC:LI10:12:LatRad_calc.INPB") #! Field("BSOC:LI10:12:LatRad_calc.OUT",16777215,1,"BSOC:LI10:12:LatRad_calc.OUT") #! Link("BSOC:LI10:12:LatRad_calc.OUT","BSOC:LI10:12:LatRad.VAL") #! Record("BSOC:LI10:12:LatRad",500,20,0,0,"BSOC:LI10:12:LatRad") #! Field("BSOC:LI10:12:LatRad.VAL",16777215,1,"BSOC:LI10:12:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi103") { field(DESC, "Port LI08_BSOIC_Rd bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:IN10:03:LatEqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:LatEqp_calc") { field(INPA, "PLC:LI08:PP02:Bi103 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:LatEqp") { field(DESC, "BSOIC-LAT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb103",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb103") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb103.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb103.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb103.FLNK","BSOC:IN10:03:LatEqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb103.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb103.VAL") #! Record("BSOC:IN10:03:LatEqp_calc",260,18,0,1,"BSOC:IN10:03:LatEqp_calc") #! Field("BSOC:IN10:03:LatEqp_calc.INPA",16777215,0,"BSOC:IN10:03:LatEqp_calc.INPA") #! Link("BSOC:IN10:03:LatEqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb103.VAL") #! Field("BSOC:IN10:03:LatEqp_calc.INPB",16777215,1,"BSOC:IN10:03:LatEqp_calc.INPB") #! Field("BSOC:IN10:03:LatEqp_calc.OUT",16777215,1,"BSOC:IN10:03:LatEqp_calc.OUT") #! Link("BSOC:IN10:03:LatEqp_calc.OUT","BSOC:IN10:03:LatEqp.VAL") #! Record("BSOC:IN10:03:LatEqp",500,20,0,0,"BSOC:IN10:03:LatEqp") #! Field("BSOC:IN10:03:LatEqp.VAL",16777215,1,"BSOC:IN10:03:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi102") { field(DESC, "Port LI08_BSOIC_Rd bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:IN10:03:LatRad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:LatRad_calc") { field(INPA, "PLC:LI08:PP02:Bi102 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:LatRad") { field(DESC, "BSOIC-LAT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb102",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb102") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb102.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb102.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb102.FLNK","BSOC:IN10:03:LatRad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb102.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb102.VAL") #! Record("BSOC:IN10:03:LatRad_calc",260,18,0,1,"BSOC:IN10:03:LatRad_calc") #! Field("BSOC:IN10:03:LatRad_calc.INPA",16777215,0,"BSOC:IN10:03:LatRad_calc.INPA") #! Link("BSOC:IN10:03:LatRad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb102.VAL") #! Field("BSOC:IN10:03:LatRad_calc.INPB",16777215,1,"BSOC:IN10:03:LatRad_calc.INPB") #! Field("BSOC:IN10:03:LatRad_calc.OUT",16777215,1,"BSOC:IN10:03:LatRad_calc.OUT") #! Link("BSOC:IN10:03:LatRad_calc.OUT","BSOC:IN10:03:LatRad.VAL") #! Record("BSOC:IN10:03:LatRad",500,20,0,0,"BSOC:IN10:03:LatRad") #! Field("BSOC:IN10:03:LatRad.VAL",16777215,1,"BSOC:IN10:03:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi101") { field(DESC, "Port LI08_BSOIC_Rd bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G3:LatEqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:LatEqp_calc") { field(INPA, "PLC:LI08:PP02:Bi101 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:LatEqp") { field(DESC, "BSOIC-LAT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb101",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb101") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb101.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb101.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb101.FLNK","BSOC:LI08:G3:LatEqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb101.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb101.VAL") #! Record("BSOC:LI08:G3:LatEqp_calc",260,18,0,1,"BSOC:LI08:G3:LatEqp_calc") #! Field("BSOC:LI08:G3:LatEqp_calc.INPA",16777215,0,"BSOC:LI08:G3:LatEqp_calc.INPA") #! Link("BSOC:LI08:G3:LatEqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb101.VAL") #! Field("BSOC:LI08:G3:LatEqp_calc.INPB",16777215,1,"BSOC:LI08:G3:LatEqp_calc.INPB") #! Field("BSOC:LI08:G3:LatEqp_calc.OUT",16777215,1,"BSOC:LI08:G3:LatEqp_calc.OUT") #! Link("BSOC:LI08:G3:LatEqp_calc.OUT","BSOC:LI08:G3:LatEqp.VAL") #! Record("BSOC:LI08:G3:LatEqp",500,20,0,0,"BSOC:LI08:G3:LatEqp") #! Field("BSOC:LI08:G3:LatEqp.VAL",16777215,1,"BSOC:LI08:G3:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi100") { field(DESC, "Port LI08_BSOIC_Rd bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G3:LatRad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:LatRad_calc") { field(INPA, "PLC:LI08:PP02:Bi100 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:LatRad") { field(DESC, "BSOIC-LAT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb100",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb100") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb100.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb100.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb100.FLNK","BSOC:LI08:G3:LatRad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb100.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb100.VAL") #! Record("BSOC:LI08:G3:LatRad_calc",260,18,0,1,"BSOC:LI08:G3:LatRad_calc") #! Field("BSOC:LI08:G3:LatRad_calc.INPA",16777215,0,"BSOC:LI08:G3:LatRad_calc.INPA") #! Link("BSOC:LI08:G3:LatRad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb100.VAL") #! Field("BSOC:LI08:G3:LatRad_calc.INPB",16777215,1,"BSOC:LI08:G3:LatRad_calc.INPB") #! Field("BSOC:LI08:G3:LatRad_calc.OUT",16777215,1,"BSOC:LI08:G3:LatRad_calc.OUT") #! Link("BSOC:LI08:G3:LatRad_calc.OUT","BSOC:LI08:G3:LatRad.VAL") #! Record("BSOC:LI08:G3:LatRad",500,20,0,0,"BSOC:LI08:G3:LatRad") #! Field("BSOC:LI08:G3:LatRad.VAL",16777215,1,"BSOC:LI08:G3:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi99") { field(DESC, "Port LI08_BSOIC_Rd bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G4:LatEqp_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:LatEqp_calc") { field(INPA, "PLC:LI08:PP02:Bi99 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:LatEqp") { field(DESC, "BSOIC-LAT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb99",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb99") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb99.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb99.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb99.FLNK","BSOC:LI08:G4:LatEqp_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb99.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb99.VAL") #! Record("BSOC:LI08:G4:LatEqp_calc",260,18,0,1,"BSOC:LI08:G4:LatEqp_calc") #! Field("BSOC:LI08:G4:LatEqp_calc.INPA",16777215,0,"BSOC:LI08:G4:LatEqp_calc.INPA") #! Link("BSOC:LI08:G4:LatEqp_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb99.VAL") #! Field("BSOC:LI08:G4:LatEqp_calc.INPB",16777215,1,"BSOC:LI08:G4:LatEqp_calc.INPB") #! Field("BSOC:LI08:G4:LatEqp_calc.OUT",16777215,1,"BSOC:LI08:G4:LatEqp_calc.OUT") #! Link("BSOC:LI08:G4:LatEqp_calc.OUT","BSOC:LI08:G4:LatEqp.VAL") #! Record("BSOC:LI08:G4:LatEqp",500,20,0,0,"BSOC:LI08:G4:LatEqp") #! Field("BSOC:LI08:G4:LatEqp.VAL",16777215,1,"BSOC:LI08:G4:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi98") { field(DESC, "Port LI08_BSOIC_Rd bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G4:LatRad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:LatRad_calc") { field(INPA, "PLC:LI08:PP02:Bi98 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:LatRad") { field(DESC, "BSOIC-LAT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb98",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb98") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb98.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb98.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb98.FLNK","BSOC:LI08:G4:LatRad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb98.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb98.VAL") #! Record("BSOC:LI08:G4:LatRad_calc",260,18,0,1,"BSOC:LI08:G4:LatRad_calc") #! Field("BSOC:LI08:G4:LatRad_calc.INPA",16777215,0,"BSOC:LI08:G4:LatRad_calc.INPA") #! Link("BSOC:LI08:G4:LatRad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb98.VAL") #! Field("BSOC:LI08:G4:LatRad_calc.INPB",16777215,1,"BSOC:LI08:G4:LatRad_calc.INPB") #! Field("BSOC:LI08:G4:LatRad_calc.OUT",16777215,1,"BSOC:LI08:G4:LatRad_calc.OUT") #! Link("BSOC:LI08:G4:LatRad_calc.OUT","BSOC:LI08:G4:LatRad.VAL") #! Record("BSOC:LI08:G4:LatRad",500,20,0,0,"BSOC:LI08:G4:LatRad") #! Field("BSOC:LI08:G4:LatRad.VAL",16777215,1,"BSOC:LI08:G4:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi97") { field(DESC, "Port LI08_BSOIC_Rd bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:N1:LatRad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N1:LatRad_calc") { field(INPA, "PLC:LI08:PP02:Bi97 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N1:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N1:LatRad") { field(DESC, "BSOIC-LAT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb97",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb97") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb97.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb97.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb97.FLNK","BSOC:LI08:N1:LatRad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb97.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb97.VAL") #! Record("BSOC:LI08:N1:LatRad_calc",260,18,0,1,"BSOC:LI08:N1:LatRad_calc") #! Field("BSOC:LI08:N1:LatRad_calc.INPA",16777215,0,"BSOC:LI08:N1:LatRad_calc.INPA") #! Link("BSOC:LI08:N1:LatRad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb97.VAL") #! Field("BSOC:LI08:N1:LatRad_calc.INPB",16777215,1,"BSOC:LI08:N1:LatRad_calc.INPB") #! Field("BSOC:LI08:N1:LatRad_calc.OUT",16777215,1,"BSOC:LI08:N1:LatRad_calc.OUT") #! Link("BSOC:LI08:N1:LatRad_calc.OUT","BSOC:LI08:N1:LatRad.VAL") #! Record("BSOC:LI08:N1:LatRad",500,20,0,0,"BSOC:LI08:N1:LatRad") #! Field("BSOC:LI08:N1:LatRad.VAL",16777215,1,"BSOC:LI08:N1:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi96") { field(DESC, "Port LI08_BSOIC_Rd bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:N2:LatRad_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N2:LatRad_calc") { field(INPA, "PLC:LI08:PP02:Bi96 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N2:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N2:LatRad") { field(DESC, "BSOIC-LAT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb96",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb96") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb96.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb96.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb96.FLNK","BSOC:LI08:N2:LatRad_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb96.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb96.VAL") #! Record("BSOC:LI08:N2:LatRad_calc",260,18,0,1,"BSOC:LI08:N2:LatRad_calc") #! Field("BSOC:LI08:N2:LatRad_calc.INPA",16777215,0,"BSOC:LI08:N2:LatRad_calc.INPA") #! Link("BSOC:LI08:N2:LatRad_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb96.VAL") #! Field("BSOC:LI08:N2:LatRad_calc.INPB",16777215,1,"BSOC:LI08:N2:LatRad_calc.INPB") #! Field("BSOC:LI08:N2:LatRad_calc.OUT",16777215,1,"BSOC:LI08:N2:LatRad_calc.OUT") #! Link("BSOC:LI08:N2:LatRad_calc.OUT","BSOC:LI08:N2:LatRad.VAL") #! Record("BSOC:LI08:N2:LatRad",500,20,0,0,"BSOC:LI08:N2:LatRad") #! Field("BSOC:LI08:N2:LatRad.VAL",16777215,1,"BSOC:LI08:N2:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi111") { field(DESC, "Port LI08_BSOIC_Rd bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:LatCascIn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:LatCascIn_calc") { field(INPA, "PLC:LI08:PP02:Bi111 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb111",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb111") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb111.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb111.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb111.FLNK","BSOC:LI08:1:LatCascIn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb111.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb111.VAL") #! Record("BSOC:LI08:1:LatCascIn_calc",260,18,0,1,"BSOC:LI08:1:LatCascIn_calc") #! Field("BSOC:LI08:1:LatCascIn_calc.INPA",16777215,0,"BSOC:LI08:1:LatCascIn_calc.INPA") #! Link("BSOC:LI08:1:LatCascIn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb111.VAL") #! Field("BSOC:LI08:1:LatCascIn_calc.INPB",16777215,1,"BSOC:LI08:1:LatCascIn_calc.INPB") #! Field("BSOC:LI08:1:LatCascIn_calc.OUT",16777215,1,"BSOC:LI08:1:LatCascIn_calc.OUT") #! Link("BSOC:LI08:1:LatCascIn_calc.OUT","BSOC:LI08:1:LatCascIn.VAL") #! Record("BSOC:LI08:1:LatCascIn",500,20,0,0,"BSOC:LI08:1:LatCascIn") #! Field("BSOC:LI08:1:LatCascIn.VAL",16777215,1,"BSOC:LI08:1:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi110") { field(DESC, "Port LI08_BSOIC_Rd bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:2:LatCascIn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:2:LatCascIn_calc") { field(INPA, "PLC:LI08:PP02:Bi110 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:2:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:2:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb110",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb110") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb110.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb110.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb110.FLNK","BSOC:LI08:2:LatCascIn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb110.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb110.VAL") #! Record("BSOC:LI08:2:LatCascIn_calc",260,18,0,1,"BSOC:LI08:2:LatCascIn_calc") #! Field("BSOC:LI08:2:LatCascIn_calc.INPA",16777215,0,"BSOC:LI08:2:LatCascIn_calc.INPA") #! Link("BSOC:LI08:2:LatCascIn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb110.VAL") #! Field("BSOC:LI08:2:LatCascIn_calc.INPB",16777215,1,"BSOC:LI08:2:LatCascIn_calc.INPB") #! Field("BSOC:LI08:2:LatCascIn_calc.OUT",16777215,1,"BSOC:LI08:2:LatCascIn_calc.OUT") #! Link("BSOC:LI08:2:LatCascIn_calc.OUT","BSOC:LI08:2:LatCascIn.VAL") #! Record("BSOC:LI08:2:LatCascIn",500,20,0,0,"BSOC:LI08:2:LatCascIn") #! Field("BSOC:LI08:2:LatCascIn.VAL",16777215,1,"BSOC:LI08:2:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi109") { field(DESC, "Port LI08_BSOIC_Rd bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:AllGOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:AllGOk_calc") { field(INPA, "PLC:LI08:PP02:Bi109 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:AllGOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:AllGOk") { field(DESC, "BSOIC-All_Gamma_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb109",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb109") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb109.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb109.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb109.FLNK","BSOC:LI08:1:AllGOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb109.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb109.VAL") #! Record("BSOC:LI08:1:AllGOk_calc",260,18,0,1,"BSOC:LI08:1:AllGOk_calc") #! Field("BSOC:LI08:1:AllGOk_calc.INPA",16777215,0,"BSOC:LI08:1:AllGOk_calc.INPA") #! Link("BSOC:LI08:1:AllGOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb109.VAL") #! Field("BSOC:LI08:1:AllGOk_calc.INPB",16777215,1,"BSOC:LI08:1:AllGOk_calc.INPB") #! Field("BSOC:LI08:1:AllGOk_calc.OUT",16777215,1,"BSOC:LI08:1:AllGOk_calc.OUT") #! Link("BSOC:LI08:1:AllGOk_calc.OUT","BSOC:LI08:1:AllGOk.VAL") #! Record("BSOC:LI08:1:AllGOk",500,20,0,0,"BSOC:LI08:1:AllGOk") #! Field("BSOC:LI08:1:AllGOk.VAL",16777215,1,"BSOC:LI08:1:AllGOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi108") { field(DESC, "Port LI08_BSOIC_Rd bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 108, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:AllNOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:AllNOk_calc") { field(INPA, "PLC:LI08:PP02:Bi108 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:AllNOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:AllNOk") { field(DESC, "BSOIC-All_Neutron_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb108",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb108") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb108.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb108.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb108.FLNK","BSOC:LI08:1:AllNOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb108.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb108.VAL") #! Record("BSOC:LI08:1:AllNOk_calc",260,18,0,1,"BSOC:LI08:1:AllNOk_calc") #! Field("BSOC:LI08:1:AllNOk_calc.INPA",16777215,0,"BSOC:LI08:1:AllNOk_calc.INPA") #! Link("BSOC:LI08:1:AllNOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb108.VAL") #! Field("BSOC:LI08:1:AllNOk_calc.INPB",16777215,1,"BSOC:LI08:1:AllNOk_calc.INPB") #! Field("BSOC:LI08:1:AllNOk_calc.OUT",16777215,1,"BSOC:LI08:1:AllNOk_calc.OUT") #! Link("BSOC:LI08:1:AllNOk_calc.OUT","BSOC:LI08:1:AllNOk.VAL") #! Record("BSOC:LI08:1:AllNOk",500,20,0,0,"BSOC:LI08:1:AllNOk") #! Field("BSOC:LI08:1:AllNOk.VAL",16777215,1,"BSOC:LI08:1:AllNOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi107") { field(DESC, "Port LI08_BSOIC_Rd bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:1:AllOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:AllOk_calc") { field(INPA, "PLC:LI08:PP02:Bi107 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:AllOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:AllOk") { field(DESC, "BSOIC-All_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb107",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb107") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb107.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb107.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb107.FLNK","BSOC:LI08:1:AllOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb107.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb107.VAL") #! Record("BSOC:LI08:1:AllOk_calc",260,18,0,1,"BSOC:LI08:1:AllOk_calc") #! Field("BSOC:LI08:1:AllOk_calc.INPA",16777215,0,"BSOC:LI08:1:AllOk_calc.INPA") #! Link("BSOC:LI08:1:AllOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb107.VAL") #! Field("BSOC:LI08:1:AllOk_calc.INPB",16777215,1,"BSOC:LI08:1:AllOk_calc.INPB") #! Field("BSOC:LI08:1:AllOk_calc.OUT",16777215,1,"BSOC:LI08:1:AllOk_calc.OUT") #! Link("BSOC:LI08:1:AllOk_calc.OUT","BSOC:LI08:1:AllOk.VAL") #! Record("BSOC:LI08:1:AllOk",500,20,0,0,"BSOC:LI08:1:AllOk") #! Field("BSOC:LI08:1:AllOk.VAL",16777215,1,"BSOC:LI08:1:AllOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi106") { field(DESC, "Port LI08_BSOIC_Rd bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 106, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI10:12:EqpWarn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:EqpWarn_calc") { field(INPA, "PLC:LI08:PP02:Bi106 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb106",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb106") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb106.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb106.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb106.FLNK","BSOC:LI10:12:EqpWarn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb106.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb106.VAL") #! Record("BSOC:LI10:12:EqpWarn_calc",260,18,0,1,"BSOC:LI10:12:EqpWarn_calc") #! Field("BSOC:LI10:12:EqpWarn_calc.INPA",16777215,0,"BSOC:LI10:12:EqpWarn_calc.INPA") #! Link("BSOC:LI10:12:EqpWarn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb106.VAL") #! Field("BSOC:LI10:12:EqpWarn_calc.INPB",16777215,1,"BSOC:LI10:12:EqpWarn_calc.INPB") #! Field("BSOC:LI10:12:EqpWarn_calc.OUT",16777215,1,"BSOC:LI10:12:EqpWarn_calc.OUT") #! Link("BSOC:LI10:12:EqpWarn_calc.OUT","BSOC:LI10:12:EqpWarn.VAL") #! Record("BSOC:LI10:12:EqpWarn",500,20,0,0,"BSOC:LI10:12:EqpWarn") #! Field("BSOC:LI10:12:EqpWarn.VAL",16777215,1,"BSOC:LI10:12:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi105") { field(DESC, "Port LI08_BSOIC_Rd bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 105, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:IN10:03:EqpWarn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:EqpWarn_calc") { field(INPA, "PLC:LI08:PP02:Bi105 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb105",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb105") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb105.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb105.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb105.FLNK","BSOC:IN10:03:EqpWarn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb105.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb105.VAL") #! Record("BSOC:IN10:03:EqpWarn_calc",260,18,0,1,"BSOC:IN10:03:EqpWarn_calc") #! Field("BSOC:IN10:03:EqpWarn_calc.INPA",16777215,0,"BSOC:IN10:03:EqpWarn_calc.INPA") #! Link("BSOC:IN10:03:EqpWarn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb105.VAL") #! Field("BSOC:IN10:03:EqpWarn_calc.INPB",16777215,1,"BSOC:IN10:03:EqpWarn_calc.INPB") #! Field("BSOC:IN10:03:EqpWarn_calc.OUT",16777215,1,"BSOC:IN10:03:EqpWarn_calc.OUT") #! Link("BSOC:IN10:03:EqpWarn_calc.OUT","BSOC:IN10:03:EqpWarn.VAL") #! Record("BSOC:IN10:03:EqpWarn",500,20,0,0,"BSOC:IN10:03:EqpWarn") #! Field("BSOC:IN10:03:EqpWarn.VAL",16777215,1,"BSOC:IN10:03:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi104") { field(DESC, "Port LI08_BSOIC_Rd bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 104, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI08:G3:EqpWarn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:EqpWarn_calc") { field(INPA, "PLC:LI08:PP02:Bi104 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb104",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb104") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb104.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb104.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb104.FLNK","BSOC:LI08:G3:EqpWarn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb104.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb104.VAL") #! Record("BSOC:LI08:G3:EqpWarn_calc",260,18,0,1,"BSOC:LI08:G3:EqpWarn_calc") #! Field("BSOC:LI08:G3:EqpWarn_calc.INPA",16777215,0,"BSOC:LI08:G3:EqpWarn_calc.INPA") #! Link("BSOC:LI08:G3:EqpWarn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb104.VAL") #! Field("BSOC:LI08:G3:EqpWarn_calc.INPB",16777215,1,"BSOC:LI08:G3:EqpWarn_calc.INPB") #! Field("BSOC:LI08:G3:EqpWarn_calc.OUT",16777215,1,"BSOC:LI08:G3:EqpWarn_calc.OUT") #! Link("BSOC:LI08:G3:EqpWarn_calc.OUT","BSOC:LI08:G3:EqpWarn.VAL") #! Record("BSOC:LI08:G3:EqpWarn",500,20,0,0,"BSOC:LI08:G3:EqpWarn") #! Field("BSOC:LI08:G3:EqpWarn.VAL",16777215,1,"BSOC:LI08:G3:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi119") { field(DESC, "Port LI08_BSOIC_Rd bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 119, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI08:G4:EqpWarn_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:EqpWarn_calc") { field(INPA, "PLC:LI08:PP02:Bi119 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb119",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb119") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb119.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb119.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb119.FLNK","BSOC:LI08:G4:EqpWarn_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb119.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb119.VAL") #! Record("BSOC:LI08:G4:EqpWarn_calc",260,18,0,1,"BSOC:LI08:G4:EqpWarn_calc") #! Field("BSOC:LI08:G4:EqpWarn_calc.INPA",16777215,0,"BSOC:LI08:G4:EqpWarn_calc.INPA") #! Link("BSOC:LI08:G4:EqpWarn_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb119.VAL") #! Field("BSOC:LI08:G4:EqpWarn_calc.INPB",16777215,1,"BSOC:LI08:G4:EqpWarn_calc.INPB") #! Field("BSOC:LI08:G4:EqpWarn_calc.OUT",16777215,1,"BSOC:LI08:G4:EqpWarn_calc.OUT") #! Link("BSOC:LI08:G4:EqpWarn_calc.OUT","BSOC:LI08:G4:EqpWarn.VAL") #! Record("BSOC:LI08:G4:EqpWarn",500,20,0,0,"BSOC:LI08:G4:EqpWarn") #! Field("BSOC:LI08:G4:EqpWarn.VAL",16777215,1,"BSOC:LI08:G4:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi117") { field(DESC, "Port LI08_BSOIC_Rd bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 117, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI08:1:PLCHB_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:1:PLCHB_calc") { field(INPA, "PLC:LI08:PP02:Bi117 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:1:PLCHB PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:1:PLCHB") { field(DESC, "BSOIC-PLC_Heartbeat") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb117",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb117") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb117.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb117.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb117.FLNK","BSOC:LI08:1:PLCHB_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb117.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb117.VAL") #! Record("BSOC:LI08:1:PLCHB_calc",260,18,0,1,"BSOC:LI08:1:PLCHB_calc") #! Field("BSOC:LI08:1:PLCHB_calc.INPA",16777215,0,"BSOC:LI08:1:PLCHB_calc.INPA") #! Link("BSOC:LI08:1:PLCHB_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb117.VAL") #! Field("BSOC:LI08:1:PLCHB_calc.INPB",16777215,1,"BSOC:LI08:1:PLCHB_calc.INPB") #! Field("BSOC:LI08:1:PLCHB_calc.OUT",16777215,1,"BSOC:LI08:1:PLCHB_calc.OUT") #! Link("BSOC:LI08:1:PLCHB_calc.OUT","BSOC:LI08:1:PLCHB.VAL") #! Record("BSOC:LI08:1:PLCHB",500,20,0,0,"BSOC:LI08:1:PLCHB") #! Field("BSOC:LI08:1:PLCHB.VAL",16777215,1,"BSOC:LI08:1:PLCHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi116") { field(DESC, "Port LI08_BSOIC_Rd bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 116, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI10:12:ChOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI10:12:ChOk_calc") { field(INPA, "PLC:LI08:PP02:Bi116 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI10:12:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI10:12:ChOk") { field(DESC, "BSOIC-CH1_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb116",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb116") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb116.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb116.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb116.FLNK","BSOC:LI10:12:ChOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb116.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb116.VAL") #! Record("BSOC:LI10:12:ChOk_calc",260,18,0,1,"BSOC:LI10:12:ChOk_calc") #! Field("BSOC:LI10:12:ChOk_calc.INPA",16777215,0,"BSOC:LI10:12:ChOk_calc.INPA") #! Link("BSOC:LI10:12:ChOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb116.VAL") #! Field("BSOC:LI10:12:ChOk_calc.INPB",16777215,1,"BSOC:LI10:12:ChOk_calc.INPB") #! Field("BSOC:LI10:12:ChOk_calc.OUT",16777215,1,"BSOC:LI10:12:ChOk_calc.OUT") #! Link("BSOC:LI10:12:ChOk_calc.OUT","BSOC:LI10:12:ChOk.VAL") #! Record("BSOC:LI10:12:ChOk",500,20,0,0,"BSOC:LI10:12:ChOk") #! Field("BSOC:LI10:12:ChOk.VAL",16777215,1,"BSOC:LI10:12:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi115") { field(DESC, "Port LI08_BSOIC_Rd bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 115, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:IN10:03:ChOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:IN10:03:ChOk_calc") { field(INPA, "PLC:LI08:PP02:Bi115 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:IN10:03:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:IN10:03:ChOk") { field(DESC, "BSOIC-CH2_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb115",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb115") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb115.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb115.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb115.FLNK","BSOC:IN10:03:ChOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb115.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb115.VAL") #! Record("BSOC:IN10:03:ChOk_calc",260,18,0,1,"BSOC:IN10:03:ChOk_calc") #! Field("BSOC:IN10:03:ChOk_calc.INPA",16777215,0,"BSOC:IN10:03:ChOk_calc.INPA") #! Link("BSOC:IN10:03:ChOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb115.VAL") #! Field("BSOC:IN10:03:ChOk_calc.INPB",16777215,1,"BSOC:IN10:03:ChOk_calc.INPB") #! Field("BSOC:IN10:03:ChOk_calc.OUT",16777215,1,"BSOC:IN10:03:ChOk_calc.OUT") #! Link("BSOC:IN10:03:ChOk_calc.OUT","BSOC:IN10:03:ChOk.VAL") #! Record("BSOC:IN10:03:ChOk",500,20,0,0,"BSOC:IN10:03:ChOk") #! Field("BSOC:IN10:03:ChOk.VAL",16777215,1,"BSOC:IN10:03:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi114") { field(DESC, "Port LI08_BSOIC_Rd bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 114, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G3:ChOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G3:ChOk_calc") { field(INPA, "PLC:LI08:PP02:Bi114 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G3:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G3:ChOk") { field(DESC, "BSOIC-CH3_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb114",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb114") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb114.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb114.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb114.FLNK","BSOC:LI08:G3:ChOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb114.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb114.VAL") #! Record("BSOC:LI08:G3:ChOk_calc",260,18,0,1,"BSOC:LI08:G3:ChOk_calc") #! Field("BSOC:LI08:G3:ChOk_calc.INPA",16777215,0,"BSOC:LI08:G3:ChOk_calc.INPA") #! Link("BSOC:LI08:G3:ChOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb114.VAL") #! Field("BSOC:LI08:G3:ChOk_calc.INPB",16777215,1,"BSOC:LI08:G3:ChOk_calc.INPB") #! Field("BSOC:LI08:G3:ChOk_calc.OUT",16777215,1,"BSOC:LI08:G3:ChOk_calc.OUT") #! Link("BSOC:LI08:G3:ChOk_calc.OUT","BSOC:LI08:G3:ChOk.VAL") #! Record("BSOC:LI08:G3:ChOk",500,20,0,0,"BSOC:LI08:G3:ChOk") #! Field("BSOC:LI08:G3:ChOk.VAL",16777215,1,"BSOC:LI08:G3:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi113") { field(DESC, "Port LI08_BSOIC_Rd bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 113, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:G4:ChOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:G4:ChOk_calc") { field(INPA, "PLC:LI08:PP02:Bi113 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:G4:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:G4:ChOk") { field(DESC, "BSOIC-CH4_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb113",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb113") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb113.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb113.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb113.FLNK","BSOC:LI08:G4:ChOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb113.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb113.VAL") #! Record("BSOC:LI08:G4:ChOk_calc",260,18,0,1,"BSOC:LI08:G4:ChOk_calc") #! Field("BSOC:LI08:G4:ChOk_calc.INPA",16777215,0,"BSOC:LI08:G4:ChOk_calc.INPA") #! Link("BSOC:LI08:G4:ChOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb113.VAL") #! Field("BSOC:LI08:G4:ChOk_calc.INPB",16777215,1,"BSOC:LI08:G4:ChOk_calc.INPB") #! Field("BSOC:LI08:G4:ChOk_calc.OUT",16777215,1,"BSOC:LI08:G4:ChOk_calc.OUT") #! Link("BSOC:LI08:G4:ChOk_calc.OUT","BSOC:LI08:G4:ChOk.VAL") #! Record("BSOC:LI08:G4:ChOk",500,20,0,0,"BSOC:LI08:G4:ChOk") #! Field("BSOC:LI08:G4:ChOk.VAL",16777215,1,"BSOC:LI08:G4:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi112") { field(DESC, "Port LI08_BSOIC_Rd bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 112, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:N1:ChOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N1:ChOk_calc") { field(INPA, "PLC:LI08:PP02:Bi112 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N1:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N1:ChOk") { field(DESC, "BSOIC-CH5_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb112",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb112") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb112.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb112.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb112.FLNK","BSOC:LI08:N1:ChOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb112.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb112.VAL") #! Record("BSOC:LI08:N1:ChOk_calc",260,18,0,1,"BSOC:LI08:N1:ChOk_calc") #! Field("BSOC:LI08:N1:ChOk_calc.INPA",16777215,0,"BSOC:LI08:N1:ChOk_calc.INPA") #! Link("BSOC:LI08:N1:ChOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb112.VAL") #! Field("BSOC:LI08:N1:ChOk_calc.INPB",16777215,1,"BSOC:LI08:N1:ChOk_calc.INPB") #! Field("BSOC:LI08:N1:ChOk_calc.OUT",16777215,1,"BSOC:LI08:N1:ChOk_calc.OUT") #! Link("BSOC:LI08:N1:ChOk_calc.OUT","BSOC:LI08:N1:ChOk.VAL") #! Record("BSOC:LI08:N1:ChOk",500,20,0,0,"BSOC:LI08:N1:ChOk") #! Field("BSOC:LI08:N1:ChOk.VAL",16777215,1,"BSOC:LI08:N1:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI08:PP02:Bi127") { field(DESC, "Port LI08_BSOIC_Rd bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 127, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI08:N2:ChOk_calc PP MS") field(ASG, "Internal") } record(calcout, "BSOC:LI08:N2:ChOk_calc") { field(INPA, "PLC:LI08:PP02:Bi127 NPP MS") field(INPB, "PLC:LI08:PP02:TABLE_9_SEG_1 CP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI08:N2:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI08:N2:ChOk") { field(DESC, "BSOIC-CH6_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI08:PP02:LI08_BSOIC_Rdb127",20,19,0,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb127") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb127.FLNK",16777215,1,"PLC:LI08:PP02:LI08_BSOIC_Rdb127.FLNK") #! Link("PLC:LI08:PP02:LI08_BSOIC_Rdb127.FLNK","BSOC:LI08:N2:ChOk_calc") #! Field("PLC:LI08:PP02:LI08_BSOIC_Rdb127.VAL",16777215,0,"PLC:LI08:PP02:LI08_BSOIC_Rdb127.VAL") #! Record("BSOC:LI08:N2:ChOk_calc",260,18,0,1,"BSOC:LI08:N2:ChOk_calc") #! Field("BSOC:LI08:N2:ChOk_calc.INPA",16777215,0,"BSOC:LI08:N2:ChOk_calc.INPA") #! Link("BSOC:LI08:N2:ChOk_calc.INPA","PLC:LI08:PP02:LI08_BSOIC_Rdb127.VAL") #! Field("BSOC:LI08:N2:ChOk_calc.INPB",16777215,1,"BSOC:LI08:N2:ChOk_calc.INPB") #! Field("BSOC:LI08:N2:ChOk_calc.OUT",16777215,1,"BSOC:LI08:N2:ChOk_calc.OUT") #! Link("BSOC:LI08:N2:ChOk_calc.OUT","BSOC:LI08:N2:ChOk.VAL") #! Record("BSOC:LI08:N2:ChOk",500,20,0,0,"BSOC:LI08:N2:ChOk") #! Field("BSOC:LI08:N2:ChOk.VAL",16777215,1,"BSOC:LI08:N2:ChOk.VAL") record(bo, "BSOC:LI10:12:SReset") { field(DESC, "BSOIC-Soft_Reset_G1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:IN10:03:SReset") { field(DESC, "BSOIC-Soft_Reset_G2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI08:G3:SReset") { field(DESC, "BSOIC-Soft_Reset_G3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 5, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI08:G4:SReset") { field(DESC, "BSOIC-Soft_Reset_G4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 4, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI08:N1:SReset") { field(DESC, "BSOIC-Soft_Reset_N1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI08:N2:SReset") { field(DESC, "BSOIC-Soft_Reset_N2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 2, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI08:1:SResetAll") { field(DESC, "BSOIC-Soft_Reset_All") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 1, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI08:1:SPauseHB") { field(DESC, "BSOIC-Soft_Pause_Hb") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Pause") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:LI08:PP02:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:LI08:PP02:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:LI08:PP02:TABLE_CYCLER") { field( OUT, "PLC:LI08:PP02:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:LI08:PP02:SEG_CYCLER") { field( OUT, "PLC:LI08:PP02:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:LI08:PP02:TABLE_9_SEG_1") { field( INPA, "PLC:LI08:PP02:REQ_TABLE CP") field( INPB, "PLC:LI08:PP02:REQ_SEG CP") field( INPC, "PLC:LI08:PP02:REQ_TABLE_IN CP") field( INPD, "PLC:LI08:PP02:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:LI08:PP02:TABLE_1_SEG_1") { field( INPA, "PLC:LI08:PP02:REQ_TABLE CP") field( INPB, "PLC:LI08:PP02:REQ_SEG CP") field( INPC, "PLC:LI08:PP02:REQ_TABLE_IN CP") field( INPD, "PLC:LI08:PP02:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI08:PP02:REQ_TABLE_OUT") { field(OUTA, "PLC:LI08:PP02:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:LI08:PP02:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:LI08:PP02:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:LI08:PP02:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:LI08:PP02:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:LI08:PP02:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:LI08:PP02:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:LI08:PP02:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:LI08:PP02:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT0 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT1 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT2 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT3 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT4 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT5 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT6 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:LI08:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI08:PP02:TABLE_BIT7 MS") field(INPC, "PLC:LI08:PP02:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI08:PP02:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:LI08:PP02:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:LI08:PP02:TABLE_BIT0 CP MS") field(INPB, "PLC:LI08:PP02:TABLE_BIT1 CP MS") field(INPC, "PLC:LI08:PP02:TABLE_BIT2 CP MS") field(INPD, "PLC:LI08:PP02:TABLE_BIT3 CP MS") field(INPE, "PLC:LI08:PP02:TABLE_BIT4 CP MS") field(INPF, "PLC:LI08:PP02:TABLE_BIT5 CP MS") field(INPG, "PLC:LI08:PP02:TABLE_BIT6 CP MS") field(INPH, "PLC:LI08:PP02:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI08:PP02:REQ_TABLE PP MS") #field(SDIS, "PLC:LI08:PP02:REQ_TABLE_OUT.PACT") } record(longout, "PLC:LI08:PP02:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:LI08:PP02:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI08:PP02:REQ_SEG_OUT") { field(OUTA, "PLC:LI08:PP02:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:LI08:PP02:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:LI08:PP02:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:LI08:PP02:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:LI08:PP02:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:LI08:PP02:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:LI08:PP02:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:LI08:PP02:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:LI08:PP02:REQ_SEG_IN.PACT") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT0 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT1 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT1 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT2 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT2 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT3 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT3 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT4 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT4 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT5 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT5 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT6 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT6 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:LI08:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI08:PP02:SEG_BIT7 MS") field(INPC, "PLC:LI08:PP02:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI08:PP02:REQ_SEG_BIT7 PP") } record(calcout, "PLC:LI08:PP02:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:LI08:PP02:SEG_BIT0 CP MS") field(INPB, "PLC:LI08:PP02:SEG_BIT1 CP MS") field(INPC, "PLC:LI08:PP02:SEG_BIT2 CP MS") field(INPD, "PLC:LI08:PP02:SEG_BIT3 CP MS") field(INPE, "PLC:LI08:PP02:SEG_BIT4 CP MS") field(INPF, "PLC:LI08:PP02:SEG_BIT5 CP MS") field(INPG, "PLC:LI08:PP02:SEG_BIT6 CP MS") field(INPH, "PLC:LI08:PP02:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI08:PP02:REQ_SEG PP MS") field(SDIS, "PLC:LI08:PP02:REQ_SEG_OUT.PACT") } record(bi, "PLC:LI08:PP02:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:PWLED") { field(DESC, "PLC-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:RUNLED") { field(DESC, "PLC-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:DIAGLED") { field(DESC, "PLC-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:FAULTLED") { field(DESC, "PLC-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:IFAULTLED") { field(DESC, "PLC-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:OFAULTLED") { field(DESC, "PLC-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI08:PP02:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Rd, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI08:PP02:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI08_BSOIC_Wrt, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:LI08:PP02:w0") { field(DESC, "Checksum word 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:w1") { field(DESC, "Checksum word 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 2, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:LI08:PP02:CHECKSUM_SDIS") { field(INPA, "PLC:LI08:PP02:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:LI08:PP02:w3") { field(DESC, "Checksum word 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 3, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:LI08:PP02:CHECKSUM_SAFE_calc") { field(INPA, "PLC:LI08:PP02:w3 PP MS") field(INPB, "PLC:LI08:PP02:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI08:PP02:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:LI08:PP02:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI08:PP02:w4") { field(DESC, "Checksum word 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 4, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:LI08:PP02:PROJ_CHECKSUM_calc") { field(INPA, "PLC:LI08:PP02:w4 NPP MS") field(INPB, "PLC:LI08:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI08:PP02:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI08:PP02:w5") { field(DESC, "Checksum word 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 5, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:LI08:PP02:DAY_MONTH_calc") { field(INPA, "PLC:LI08:PP02:w5 NPP MS") field(INPB, "PLC:LI08:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI08:PP02:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:LI08:PP02:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:LI08:PP02:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:LI08:PP02:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:LI08:PP02:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI08:PP02:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 6, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:LI08:PP02:PROJ_YEAR_calc") { field(INPA, "PLC:LI08:PP02:w6 NPP MS") field(INPB, "PLC:LI08:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI08:PP02:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI08:PP02:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 7, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI08:PP02:OP_HRS_MSB_calc") { field(INPA, "PLC:LI08:PP02:w7 NPP MS") field(INPB, "PLC:LI08:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI08:PP02:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI08_BSOIC_Wd, 8, 0xFFFF, 1)") field(FLNK, "PLC:LI08:PP02:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI08:PP02:OP_HRS_LSB_calc") { field(INPA, "PLC:LI08:PP02:w8 NPP MS") field(INPB, "PLC:LI08:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI08:PP02:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI08:PP02:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:LI08:PP02:OP_HOURS") { field(INPA, "PLC:LI08:PP02:OP_HRS_MSB CP MS") field(INPB, "PLC:LI08:PP02:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:LI08:PP02:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:LI08:PP02:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:LI08:PP02:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI08_BSOIC_Rd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI08:PP02:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI08:PP02:RDHist.PROC") } record(waveform,"PLC:LI08:PP02:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI08_BSOIC_Rd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI08:PP02:RDHistTimeAxis.PROC") } record(waveform,"PLC:LI08:PP02:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI08_BSOIC_Rd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI08:PP02:RDReadOK.PROC") } record(longout,"PLC:LI08:PP02:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI08_BSOIC_Rd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI08:PP02:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Rd 0)READ_OK") field(FLNK,"PLC:LI08:PP02:RDWriteOK.PROC") } record(longin,"PLC:LI08:PP02:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Rd 0)WRITE_OK") field(FLNK,"PLC:LI08:PP02:RDIOErrors.PROC") } record(longin,"PLC:LI08:PP02:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Rd 0)IO_ERRORS") field(FLNK,"PLC:LI08:PP02:RDLastIOTime.PROC") } record(longin,"PLC:LI08:PP02:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Rd 0)LAST_IO_TIME") field(FLNK,"PLC:LI08:PP02:RDMaxIOTime.PROC") } record(longin,"PLC:LI08:PP02:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Rd 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI08:PP02:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI08_BSOIC_Wrt 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI08:PP02:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI08:PP02:WRTHist.PROC") } record(waveform,"PLC:LI08:PP02:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI08_BSOIC_Wrt 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI08:PP02:WRTHistTimeAxis.PROC") } record(waveform,"PLC:LI08:PP02:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI08_BSOIC_Wrt 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI08:PP02:WRTReadOK.PROC") } record(longout,"PLC:LI08:PP02:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI08_BSOIC_Wrt 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI08:PP02:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wrt 0)READ_OK") field(FLNK,"PLC:LI08:PP02:WRTWriteOK.PROC") } record(longin,"PLC:LI08:PP02:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wrt 0)WRITE_OK") field(FLNK,"PLC:LI08:PP02:WRTIOErrors.PROC") } record(longin,"PLC:LI08:PP02:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wrt 0)IO_ERRORS") field(FLNK,"PLC:LI08:PP02:WRTLastIOTime.PROC") } record(longin,"PLC:LI08:PP02:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wrt 0)LAST_IO_TIME") field(FLNK,"PLC:LI08:PP02:WRTMaxIOTime.PROC") } record(longin,"PLC:LI08:PP02:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wrt 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI08:PP02:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI08_BSOIC_Wd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI08:PP02:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI08:PP02:WDHist.PROC") } record(waveform,"PLC:LI08:PP02:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI08_BSOIC_Wd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI08:PP02:WDHistTimeAxis.PROC") } record(waveform,"PLC:LI08:PP02:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI08_BSOIC_Wd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI08:PP02:WDReadOK.PROC") } record(longout,"PLC:LI08:PP02:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI08_BSOIC_Wd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI08:PP02:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wd 0)READ_OK") field(FLNK,"PLC:LI08:PP02:WDWriteOK.PROC") } record(longin,"PLC:LI08:PP02:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wd 0)WRITE_OK") field(FLNK,"PLC:LI08:PP02:WDIOErrors.PROC") } record(longin,"PLC:LI08:PP02:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wd 0)IO_ERRORS") field(FLNK,"PLC:LI08:PP02:WDLastIOTime.PROC") } record(longin,"PLC:LI08:PP02:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wd 0)LAST_IO_TIME") field(FLNK,"PLC:LI08:PP02:WDMaxIOTime.PROC") } record(longin,"PLC:LI08:PP02:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI08_BSOIC_Wd 0)MAX_IO_TIME") } record(bi, "PLC:LI08:1:S7_STATUS") { field(DTYP, "S7plc stat") field(INP, "@PLC_LI08_PP01") field(SCAN, "I/O Intr") field(ZNAM, "Disconnected") field(ONAM, "Connected") field(ZSV, "MAJOR") field(FLNK, "PLC:LI08:1:S7_STAT_COUNTER") } record(calc, "PLC:LI08:1:S7_STAT_COUNTER") { field(INPA, "PLC:LI08:1:S7_STAT_COUNTER") field(CALC, "A+1") field(FLNK, "PLC:LI08:1:S7_DISCONNECT_COUNTER") } record(calc, "PLC:LI08:1:S7_DISCONNECT_COUNTER") { field(INPA, "PLC:LI08:1:S7_STATUS") field(INPB, "PLC:LI08:1:S7_DISCONNECT_COUNTER.LA") field(INPC, "PLC:LI08:1:S7_DISCONNECT_COUNTER") field(CALC, "(A=0&&B=1)?C+1:C") } record(ai, "BSOC:LI10:12:GAMMAPLC") { field(DESC, "LI08-10ADIT BSOLNW12 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/118 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI10:12:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI10:12:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI10:12:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI10:12:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI10:12:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI10:12:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(ai, "BSOC:IN10:03:GAMMAPLC") { field(DESC, "LI08-10ADIT BSOLNM03 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/120 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:IN10:03:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:IN10:03:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:IN10:03:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:IN10:03:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:IN10:03:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:IN10:03:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI10:12:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI10:12:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI10:12:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI10:12:WARNINGMODE") field(INPB, "BSOC:LI10:12:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI10:12:WARNINGMODE",3440,3386,0,1,"BSOC:LI10:12:WARNINGMODE") #! Field("BSOC:LI10:12:WARNINGMODE.VAL",16777215,1,"BSOC:LI10:12:WARNINGMODE.VAL") #! Field("BSOC:LI10:12:WARNINGMODE.FLNK",16777215,1,"BSOC:LI10:12:WARNINGMODE.FLNK") #! Link("BSOC:LI10:12:WARNINGMODE.FLNK","BSOC:LI10:12:CALCWARNING") #! Record("BSOC:LI10:12:CALCWARNING",3760,3400,0,0,"BSOC:LI10:12:CALCWARNING") #! Field("BSOC:LI10:12:CALCWARNING.INPA",16777215,0,"BSOC:LI10:12:CALCWARNING.INPA") #! Link("BSOC:LI10:12:CALCWARNING.INPA","BSOC:LI10:12:WARNINGMODE.VAL") #! Field("BSOC:LI10:12:CALCWARNING.INPB",16777215,1,"BSOC:LI10:12:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:IN10:03:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(FLNK, "BSOC:IN10:03:CALCWARNING") field(VAL, "0") field(ASG, "MCC") } # Note: autobypass when autobypass PV is 0 record(calcout, "BSOC:IN10:03:CALCWARNING") { field(CALC, "(!A)*B*(!C)") field(INPA, "BSOC:IN10:03:WARNINGMODE") field(INPB, "BSOC:IN10:03:GAMMAACT.SEVR CPP") field(INPC, "BSOC:IN10:03:HWBypass CPP") field(SCAN, "2 second") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:IN10:03:WARNINGMODE",3440,3386,0,1,"BSOC:IN10:03:WARNINGMODE") #! Field("BSOC:IN10:03:WARNINGMODE.VAL",16777215,1,"BSOC:IN10:03:WARNINGMODE.VAL") #! Field("BSOC:IN10:03:WARNINGMODE.FLNK",16777215,1,"BSOC:IN10:03:WARNINGMODE.FLNK") #! Link("BSOC:IN10:03:WARNINGMODE.FLNK","BSOC:IN10:03:CALCWARNING") #! Record("BSOC:IN10:03:CALCWARNING",3760,3414,0,0,"BSOC:IN10:03:CALCWARNING") #! Field("BSOC:IN10:03:CALCWARNING.INPA",16777215,0,"BSOC:IN10:03:CALCWARNING.INPA") #! Link("BSOC:IN10:03:CALCWARNING.INPA","BSOC:IN10:03:WARNINGMODE.VAL") #! Field("BSOC:IN10:03:CALCWARNING.INPB",16777215,1,"BSOC:IN10:03:CALCWARNING.INPB") #! Field("BSOC:IN10:03:CALCWARNING.INPC",16777215,1,"BSOC:IN10:03:CALCWARNING.INPC") record(longin, "RADM:LI08:1:DoseRate") { field(DESC, "LI08-10ADIT RDM #1 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/26 T=WORD") } record(longin, "RADM:LI08:2:DoseRate") { field(DESC, "LI08-10ADIT RDM #2 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/28 T=WORD") } record(longin, "PPS:LI08:1:SearchTimer") { field(DESC, "LI08-LI10ADIT Search Timer (units?)") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/44 T=WORD") } record(longin, "PPS:LI08:1:BeamImminentTimer") { field(DESC, "LI08-LI10ADIT Beam Imnnt Wrn timer sec") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/46 T=BYTE") } record(bi, "PLC:LI08:1:TestMode") { field(DESC, "LI08-LI10ADIT In TEST Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=0") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:DC:Ok") { field(DESC, "LI08-LI10ADIT 24VDC-PS DC Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:DC:Status") { field(DESC, "LI08-LI10ADIT 24VDC-PS Status Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=2") field(ZNAM, "FALSE") field(ONAM, "TRUE") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:DC:UpsFaultStatus") { field(DESC, "LI08-LI10ADIT DC UPS Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:DC:UpsMode") { field(DESC, "LI08-LI10ADIT DC UPS in Battery Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=4") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI08:1:DC:UpsCharging") { field(DESC, "LI08-LI10ADIT DC UPS Battery Charging") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=5") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI08:1:ZoneSwitchFault") { field(DESC, "LI08-LI10ADIT Zone Network Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:ChainASwitchFault") { field(DESC, "LI08-LI10ADIT ChA Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/134 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:ChainBSwitchFault") { field(DESC, "LI08-LI10ADIT ChB Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:Locked") { field(DESC, "S8 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:Locked") { field(DESC, "S9 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=2") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:Locked") { field(DESC, "S10ADIT Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=3") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AvLitContA") { field(DESC, "S8 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AvLitContB") { field(DESC, "S8 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AudioPlay") { field(DESC, "LI08-LI10ADIT TOA EV-20R message playing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/135 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AllZoneClear") { field(DESC, "LI08-LI10ADIT All zone CLEAR summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=0") field(ZNAM, "NOT_CLEAR") field(ONAM, "CLEAR") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "ODM:LI08:1:Sumy") { field(DESC, "LI08-LI10ADIT ODM Sum Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI08:1:Sumy") { field(DESC, "LI08-LI10ADIT RDM Ok Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=2") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AllZoneHazOff") { field(DESC, "LI08-LI10ADIT All Zn/Haz off Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=3") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AllKeybank") { field(DESC, "LI08-LI10ADIT All Kbnk Cplt Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:SYSW:4:Off") { field(DESC, "LI08-LI10ADIT West Global is in OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=5") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:SYSW:4:ZoneEntry") { field(DESC, "LI08-LI10ADIT W Gbl in Zn Entry Enabld") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=6") field(ZNAM, "Entry_Not_Set") field(ONAM, "Entry_Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:SYSW:4:BeamReady") { field(DESC, "LI08-LI10ADIT W Gbl in Rdy for Beam") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/136 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:FanKeyswitch") { field(DESC, "S10 LINAC fan KeySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresetPr8W") { field(DESC, "Preset PR-8W") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:PresetPr10A") { field(DESC, "Preset PR-10A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:PresetPr10S") { field(DESC, "Preset PR-10S") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EnableKeyswitch") { field(DESC, "LI08-LI10ADIT RF En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=4") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:AvLitContA") { field(DESC, "S9 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:AvLitContB") { field(DESC, "S9 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:LinacSupFanInhibit") { field(DESC, "S10 Inhibit LINAC Supply Fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/137 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI08:1:BypKeyswitch") { field(DESC, "LI08-LI10ADIT RDM Bypass KeySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=0") field(ZNAM, "Normal") field(ONAM, "Override") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "ODM:LI08:1:BypKeyswitch") { field(DESC, "LI08-LI10ADIT ODM Bypass keySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=1") field(ZNAM, "Normal") field(ONAM, "Override") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:1:MwFanCont") { field(DESC, "S8 MW fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwFanSwitch") { field(DESC, "S8 MW Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwFanCont") { field(DESC, "S9 MW fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwFanSwitch") { field(DESC, "S9 MW Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwFanInhibit") { field(DESC, "Inhibit S8 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwFanInhibit") { field(DESC, "Inhibit S9 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/138 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:YmYellow") { field(DESC, "LI08-LI10ADIT Y/M Light Yellow") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/139 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:YmMagenta") { field(DESC, "LI08-LI10ADIT Y/M Light Magenta") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/139 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PermAccess") { field(DESC, "LI08-LI10ADIT Zone in Permitted Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/139 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:CtrlAccess") { field(DESC, "LI08-LI10ADIT Zone in Controlled Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/139 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:RestAccess") { field(DESC, "LI08-LI10ADIT Zone in Restricted Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/139 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:NoAccess") { field(DESC, "LI08-LI10ADIT Zone in No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/139 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:MaglockOn") { field(DESC, "S8 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/140 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI09:1:MaglockOn") { field(DESC, "S9 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/140 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI10:1:MaglockOn") { field(DESC, "S10ADIT Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/140 T=BYTE B=2") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:1:AcPlcHeartbeat") { field(DESC, "LI08-LI10ADIT PLC HB AC_PLC Pulse Source") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/140 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:LlrfPmtIntrtd") { field(DESC, "LI08-LI10ADIT LRF Permit interrupted") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/140 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:Lockout") { field(DESC, "LI08-LI10ADIT Door Lockout") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/140 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:AllDoorGateClsd") { field(DESC, "LI08-LI10ADIT All RT primtr Drs/Gts Cls") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/141 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:HbA") { field(DESC, "LI08-LI10ADIT Sfty Intlk PLC Ch-A HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/141 T=BYTE B=1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:HbB") { field(DESC, "LI08-LI10ADIT Sfty Intlk PLC Ch-B HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/141 T=BYTE B=2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:HbA") { field(DESC, "LI08-LI10ADIT Stopr Ctrl PLC Ch-A HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/141 T=BYTE B=3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:HbB") { field(DESC, "LI08-LI10ADIT Stopr Ctrl PLC Ch-B HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/141 T=BYTE B=4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "DOOR:LI09:1:Release") { field(DESC, "S9 MW Door ACR Remote DIB") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/101 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "DOOR:LI10:1:Release") { field(DESC, "S10ADIT Chicane Door ACR Remote DIB") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/101 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:InterlockReset") { field(DESC, "LI08-10ADIT Reset Interlocks") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/101 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqSearchReset") { field(DESC, "LI08-10ADIT ACR Remote Reset Search") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/101 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqIntSearch") { field(DESC, "LI08-10ADIT Interrupt Preserved Search") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/101 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI08:1:ReqSuspIntHrtbt") { field(DESC, "LI08-10ADIT Pause PLC Heartbeat Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/102 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI08:3:ReqSuspStpHrtbt") { field(DESC, "LI08-LI10ADIT Soft Pause PLC HB Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/103 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqPermAccess") { field(DESC, "LI08-10ADIT Bail to P/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/105 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqCtrlAccess") { field(DESC, "LI08-10ADIT Bail to C/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/105 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqRestAccess") { field(DESC, "LI08-10ADIT Bail to R/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/105 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqNoAccess") { field(DESC, "LI08-10ADIT Bail to N/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/105 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI09:1:KeybankRelease") { field(DESC, "S9 MW KB1 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/105 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI09:2:KeybankRelease") { field(DESC, "S9 MW KB2 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/105 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI09:3:KeybankRelease") { field(DESC, "S9 MW KB3 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI10:1:KeybankRelease") { field(DESC, "S10ADIT KB1 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI10:2:KeybankRelease") { field(DESC, "S10ADIT KB2 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqOpnHatch") { field(DESC, "S8 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI08:1:ReqClsHatch") { field(DESC, "S8 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI09:1:ReqOpnHatch") { field(DESC, "S9 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI09:1:ReqClsHatch") { field(DESC, "S9 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/106 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI08:1:ClearHBFault") { field(DESC, "LI08-10ADIT Clear HB Fault Warning") field(DTYP, "S7plc") field(OUT, "@PLC_LI08_PP01/109 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bi, "DOOR:LI08:1:Closed") { field(DESC, "S8 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:Hatch") { field(DESC, "S8 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:EExit") { field(DESC, "S8 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:2:Closed") { field(DESC, "S8 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:Closed") { field(DESC, "S9 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:Hatch") { field(DESC, "S9 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:Keybank") { field(DESC, "S9 MW KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:Keybank") { field(DESC, "S9 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/56 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:3:Keybank") { field(DESC, "S9 MW KB3 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:EExit") { field(DESC, "S9 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:2:Closed") { field(DESC, "S9 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:Closed") { field(DESC, "S10ADIT Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:Gate") { field(DESC, "S10ADIT Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:2:Closed") { field(DESC, "S10ADIT Equipment Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:Keybank") { field(DESC, "S10ADIT KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:2:Keybank") { field(DESC, "S10ADIT KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/57 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:EExit") { field(DESC, "S10ADIT Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:Gate") { field(DESC, "LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EExit") { field(DESC, "LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwEOString") { field(DESC, "S8 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwEOString") { field(DESC, "S9 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOString") { field(DESC, "S8 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:EOString") { field(DESC, "S9 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:EOString") { field(DESC, "S10ADIT Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/58 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:OFAULT") { field(DESC, "Pilz_2_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/59 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:IFAULT") { field(DESC, "Pilz_2_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/59 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:FAULT") { field(DESC, "Pilz_2_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/59 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:DIAG") { field(DESC, "Pilz_2_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/59 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:RUN") { field(DESC, "Pilz_2_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/59 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:COMM") { field(DESC, "Pilz_2_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/59 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:Preset") { field(DESC, "S8 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:2:Preset") { field(DESC, "S8 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI09:1:Preset") { field(DESC, "S9 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI09:2:Preset") { field(DESC, "S9 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:1:YmOverrdStat") { field(DESC, "LI08-10ADIT Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=4") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:3:SearchReset") { field(DESC, "LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=5") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:XInterlockIn") { field(DESC, "Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/64 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:LocSearchReset") { field(DESC, "Search Reset Local KeySW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:ClosedLatch") { field(DESC, "LAT S8 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:HatchLatch") { field(DESC, "LAT S8 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:EExitLatch") { field(DESC, "LAT S8 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:2:ClosedLatch") { field(DESC, "LAT S8 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:ClosedLatch") { field(DESC, "LAT S9 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:HatchLatch") { field(DESC, "LAT S9 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:KeybankLatch") { field(DESC, "LAT S9 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/65 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:KeybankLatch") { field(DESC, "LAT S9 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:3:KeybankLatch") { field(DESC, "LAT S9 MW KB3 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:EExitLatch") { field(DESC, "LAT S9 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:2:ClosedLatch") { field(DESC, "LAT S9 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:ClosedLatch") { field(DESC, "LAT S10ADIT Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:GateLatch") { field(DESC, "LAT S10ADIT Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:2:ClosedLatch") { field(DESC, "LAT S10ADIT Equipment Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:KeybankLatch") { field(DESC, "LAT S10ADIT KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/66 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:2:KeybankLatch") { field(DESC, "LAT S10ADIT KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:EExitLatch") { field(DESC, "LAT S10ADIT Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:GateLatch") { field(DESC, "LAT LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EExitLatch") { field(DESC, "LAT LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwEOStringLatch") { field(DESC, "LAT S8 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwEOStringLatch") { field(DESC, "LAT S9 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOStringLatch") { field(DESC, "LAT S8 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:EOStringLatch") { field(DESC, "LAT S9 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/67 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:EOStringLatch") { field(DESC, "LAT S10ADIT Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/68 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:XRadReady") { field(DESC, "LI08-10ADIT Rad Ready Cross-interlock") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/68 T=BYTE B=5") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneIntact") { field(DESC, "LI08-10ADIT Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/68 T=BYTE B=6") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneClear") { field(DESC, "LI08-10ADIT Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/68 T=BYTE B=7") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneRadReady") { field(DESC, "LI08-10ADIT Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=0") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PlayAudio") { field(DESC, "LI08-10ADIT Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:SearchResetOut") { field(DESC, "LI08-10ADIT Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresetSet") { field(DESC, "S8 MW Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:2:PresetSet") { field(DESC, "S8 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresSearch") { field(DESC, "S8 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresSearchTimer") { field(DESC, "S8 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=6") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI09:1:PresetSet") { field(DESC, "S9 MW Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/69 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:PresetSet") { field(DESC, "S9 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:PresSearch") { field(DESC, "S9 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=1") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:PresSearchTimer") { field(DESC, "S9 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=2") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI08:1:ZoneKeybanks") { field(DESC, "LI08-10ADIT Zone Local Keybanks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneNoAccess") { field(DESC, "LI08-10ADIT Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneInterlock") { field(DESC, "LI08-10ADIT Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:BeamImminentTiming") { field(DESC, "LI08-10ADIT Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI08:1:BeamImminentTimeCplt") { field(DESC, "LI08-10ADIT Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/70 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:CommHeartbeat") { field(DESC, "LI08-10ADIT Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/71 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOSumyLatch") { field(DESC, "LI08-10ADIT EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/71 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:OFAULT") { field(DESC, "Pilz_3_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/175 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:IFAULT") { field(DESC, "Pilz_3_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/175 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:FAULT") { field(DESC, "Pilz_3_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/175 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:DIAG") { field(DESC, "Pilz_3_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/175 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:RUN") { field(DESC, "Pilz_3_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/175 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:COMM") { field(DESC, "Pilz_3_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/175 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:PlcHeartbeat") { field(DESC, "LI08-LI10ADIT PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/182 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:CommHeartbeat") { field(DESC, "LI08-LI10ADIT Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/182 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:ClosedA") { field(DESC, "S8 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:HatchA") { field(DESC, "S8 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:EExitA") { field(DESC, "S8 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:2:ClosedA") { field(DESC, "S8 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:ClosedA") { field(DESC, "S9 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:HatchA") { field(DESC, "S9 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:KeybankA") { field(DESC, "S9 MW KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:KeybankA") { field(DESC, "S9 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/74 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:3:KeybankA") { field(DESC, "S9 MW KB3 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:EExitA") { field(DESC, "S9 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:2:ClosedA") { field(DESC, "S9 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:ClosedA") { field(DESC, "S10ADIT Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:GateA") { field(DESC, "S10ADIT Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:2:ClosedA") { field(DESC, "S10ADIT Equipment Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:KeybankA") { field(DESC, "S10ADIT KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:2:KeybankA") { field(DESC, "S10ADIT KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/75 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:EExitA") { field(DESC, "S10ADIT Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:GateA") { field(DESC, "LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EExitA") { field(DESC, "LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwEOStringA") { field(DESC, "S8 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwEOStringA") { field(DESC, "S9 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOStringA") { field(DESC, "S8 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:EOStringA") { field(DESC, "S9 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:EOStringA") { field(DESC, "S10ADIT Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/76 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:OFAULTA") { field(DESC, "Pilz_2A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/77 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:IFAULTA") { field(DESC, "Pilz_2A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/77 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:FAULTA") { field(DESC, "Pilz_2A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/77 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:DIAGA") { field(DESC, "Pilz_2A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/77 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:RUNA") { field(DESC, "Pilz_2A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/77 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:COMMA") { field(DESC, "Pilz_2A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/77 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresetA") { field(DESC, "S8 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:2:PresetA") { field(DESC, "S8 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI09:1:PresetA") { field(DESC, "S9 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI09:2:PresetA") { field(DESC, "S9 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:1:YmOverrdStatA") { field(DESC, "LI08-10ADIT Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=4") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:3:SearchResetA") { field(DESC, "LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=5") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:XInterlockInA") { field(DESC, "Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/82 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:LocSearchResetA") { field(DESC, "Search Reset Local KeySW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:ClosedLatchA") { field(DESC, "LAT S8 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:HatchLatchA") { field(DESC, "LAT S8 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:EExitLatchA") { field(DESC, "LAT S8 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:2:ClosedLatchA") { field(DESC, "LAT S8 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:ClosedLatchA") { field(DESC, "LAT S9 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:HatchLatchA") { field(DESC, "LAT S9 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:KeybankLatchA") { field(DESC, "LAT S9 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/83 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:KeybankLatchA") { field(DESC, "LAT S9 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:3:KeybankLatchA") { field(DESC, "LAT S9 MW KB3 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:EExitLatchA") { field(DESC, "LAT S9 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:2:ClosedLatchA") { field(DESC, "LAT S9 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:ClosedLatchA") { field(DESC, "LAT S10ADIT Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:GateLatchA") { field(DESC, "LAT S10ADIT Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:2:ClosedLatchA") { field(DESC, "LAT S10ADIT Equipment Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:KeybankLatchA") { field(DESC, "LAT S10ADIT KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/84 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:2:KeybankLatchA") { field(DESC, "LAT S10ADIT KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:EExitLatchA") { field(DESC, "LAT S10ADIT Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:GateLatchA") { field(DESC, "LAT LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EExitLatchA") { field(DESC, "LAT LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwEOStringLatchA") { field(DESC, "LAT S8 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwEOStringLatchA") { field(DESC, "LAT S9 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOStringLatchA") { field(DESC, "LAT S8 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:EOStringLatchA") { field(DESC, "LAT S9 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/85 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:EOStringLatchA") { field(DESC, "LAT S10ADIT Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/86 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:XRadReadyA") { field(DESC, "LI08-10ADIT Rad Ready Cross-interlock") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/86 T=BYTE B=5") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneIntactA") { field(DESC, "LI08-10ADIT Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/86 T=BYTE B=6") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneClearA") { field(DESC, "LI08-10ADIT Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/86 T=BYTE B=7") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneRadReadyA") { field(DESC, "LI08-10ADIT Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=0") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PlayAudioA") { field(DESC, "LI08-10ADIT Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:SearchResetOutA") { field(DESC, "LI08-10ADIT Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresetSetA") { field(DESC, "S8 MW Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:2:PresetSetA") { field(DESC, "S8 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresSearchA") { field(DESC, "S8 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresSearchTimerA") { field(DESC, "S8 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=6") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI09:1:PresetSetA") { field(DESC, "S9 MW Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/87 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:PresetSetA") { field(DESC, "S9 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:PresSearchA") { field(DESC, "S9 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=1") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:PresSearchTimerA") { field(DESC, "S9 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=2") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI08:1:ZoneKeybanksA") { field(DESC, "LI08-10ADIT Zone Local Keybanks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneNoAccessA") { field(DESC, "LI08-10ADIT Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneInterlockA") { field(DESC, "LI08-10ADIT Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:BeamImminentTimingA") { field(DESC, "LI08-10ADIT Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI08:1:BeamImminentTimeCpltA") { field(DESC, "LI08-10ADIT Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/88 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:CommHeartbeatA") { field(DESC, "LI08-10ADIT Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/89 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOSumyLatchA") { field(DESC, "LI08-10ADIT EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/89 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:OFAULTA") { field(DESC, "Pilz_3A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/193 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:IFAULTA") { field(DESC, "Pilz_3A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/193 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:FAULTA") { field(DESC, "Pilz_3A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/193 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:DIAGA") { field(DESC, "Pilz_3A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/193 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:RUNA") { field(DESC, "Pilz_3A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/193 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:COMMA") { field(DESC, "Pilz_3A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/193 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:PlcHeartbeatA") { field(DESC, "LI08-LI10ADIT PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/200 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:CommHeartbeatA") { field(DESC, "LI08-LI10ADIT Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/200 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:ClosedB") { field(DESC, "S8 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:HatchB") { field(DESC, "S8 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:EExitB") { field(DESC, "S8 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:2:ClosedB") { field(DESC, "S8 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:ClosedB") { field(DESC, "S9 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:HatchB") { field(DESC, "S9 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:KeybankB") { field(DESC, "S9 MW KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:KeybankB") { field(DESC, "S9 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/92 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:3:KeybankB") { field(DESC, "S9 MW KB3 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:EExitB") { field(DESC, "S9 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:2:ClosedB") { field(DESC, "S9 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:ClosedB") { field(DESC, "S10ADIT Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:GateB") { field(DESC, "S10ADIT Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:2:ClosedB") { field(DESC, "S10ADIT Equipment Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:KeybankB") { field(DESC, "S10ADIT KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:2:KeybankB") { field(DESC, "S10ADIT KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/93 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:EExitB") { field(DESC, "S10ADIT Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:GateB") { field(DESC, "LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EExitB") { field(DESC, "LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwEOStringB") { field(DESC, "S8 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwEOStringB") { field(DESC, "S9 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOStringB") { field(DESC, "S8 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:EOStringB") { field(DESC, "S9 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:EOStringB") { field(DESC, "S10ADIT Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/94 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:OFAULTB") { field(DESC, "Pilz_2B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/95 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:IFAULTB") { field(DESC, "Pilz_2B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/95 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:FAULTB") { field(DESC, "Pilz_2B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/95 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:2:DIAGB") { field(DESC, "Pilz_2B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/95 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:RUNB") { field(DESC, "Pilz_2B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/95 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:COMMB") { field(DESC, "Pilz_2B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/95 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresetB") { field(DESC, "S8 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:2:PresetB") { field(DESC, "S8 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI09:1:PresetB") { field(DESC, "S9 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI09:2:PresetB") { field(DESC, "S9 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:1:YmOverrdStatB") { field(DESC, "LI08-10ADIT Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=4") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:3:SearchResetB") { field(DESC, "LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=5") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:XInterlockInB") { field(DESC, "Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/100 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:LocSearchResetB") { field(DESC, "Search Reset Local KeySW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:ClosedLatchB") { field(DESC, "LAT S8 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:HatchLatchB") { field(DESC, "LAT S8 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:1:EExitLatchB") { field(DESC, "LAT S8 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI08:2:ClosedLatchB") { field(DESC, "LAT S8 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:ClosedLatchB") { field(DESC, "LAT S9 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:HatchLatchB") { field(DESC, "LAT S9 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:KeybankLatchB") { field(DESC, "LAT S9 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/101 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:KeybankLatchB") { field(DESC, "LAT S9 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:3:KeybankLatchB") { field(DESC, "LAT S9 MW KB3 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:1:EExitLatchB") { field(DESC, "LAT S9 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI09:2:ClosedLatchB") { field(DESC, "LAT S9 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:ClosedLatchB") { field(DESC, "LAT S10ADIT Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:GateLatchB") { field(DESC, "LAT S10ADIT Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:2:ClosedLatchB") { field(DESC, "LAT S10ADIT Equipment Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:KeybankLatchB") { field(DESC, "LAT S10ADIT KB1 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/102 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:2:KeybankLatchB") { field(DESC, "LAT S10ADIT KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI10:1:EExitLatchB") { field(DESC, "LAT S10ADIT Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:GateLatchB") { field(DESC, "LAT LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EExitLatchB") { field(DESC, "LAT LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:MwEOStringLatchB") { field(DESC, "LAT S8 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:MwEOStringLatchB") { field(DESC, "LAT S9 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOStringLatchB") { field(DESC, "LAT S8 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:EOStringLatchB") { field(DESC, "LAT S9 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/103 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI10:1:EOStringLatchB") { field(DESC, "LAT S10ADIT Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/104 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:XRadReadyB") { field(DESC, "LI08-10ADIT Rad Ready Cross-interlock") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/104 T=BYTE B=5") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneIntactB") { field(DESC, "LI08-10ADIT Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/104 T=BYTE B=6") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneClearB") { field(DESC, "LI08-10ADIT Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/104 T=BYTE B=7") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneRadReadyB") { field(DESC, "LI08-10ADIT Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=0") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PlayAudioB") { field(DESC, "LI08-10ADIT Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:SearchResetOutB") { field(DESC, "LI08-10ADIT Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresetSetB") { field(DESC, "S8 MW Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:2:PresetSetB") { field(DESC, "S8 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresSearchB") { field(DESC, "S8 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:PresSearchTimerB") { field(DESC, "S8 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=6") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI09:1:PresetSetB") { field(DESC, "S9 MW Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/105 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:2:PresetSetB") { field(DESC, "S9 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:PresSearchB") { field(DESC, "S9 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=1") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI09:1:PresSearchTimerB") { field(DESC, "S9 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=2") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI08:1:ZoneKeybanksB") { field(DESC, "LI08-10ADIT Zone Local Keybanks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneNoAccessB") { field(DESC, "LI08-10ADIT Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:ZoneInterlockB") { field(DESC, "LI08-10ADIT Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:BeamImminentTimingB") { field(DESC, "LI08-10ADIT Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI08:1:BeamImminentTimeCpltB") { field(DESC, "LI08-10ADIT Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/106 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:2:CommHeartbeatB") { field(DESC, "LI08-10ADIT Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/107 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI08:1:EOSumyLatchB") { field(DESC, "LI08-10ADIT EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/107 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:OFAULTB") { field(DESC, "Pilz_3B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/211 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:IFAULTB") { field(DESC, "Pilz_3B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/211 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:FAULTB") { field(DESC, "Pilz_3B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/211 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI08:3:DIAGB") { field(DESC, "Pilz_3B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/211 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:RUNB") { field(DESC, "Pilz_3B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/211 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:COMMB") { field(DESC, "Pilz_3B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/211 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:PlcHeartbeatB") { field(DESC, "LI08-LI10ADIT PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/218 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:3:CommHeartbeatB") { field(DESC, "LI08-LI10ADIT Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/218 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI08:1:SafetyMode") { field(DESC, "AC_PLC Safety Mode. 1 = Deactivated") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/31 T=BYTE B=0") field(ZNAM, "Activated") field(ONAM, "Deactivated") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(longin, "PLC:LI08:1:SAFETY_SIG") { field(DESC, "Safety_Signature") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/20 T=DWORD") } record(longin, "PLC:LI08:2A:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2A_Int_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/24 T=WORD") } record(longin, "PLC:LI08:2B:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2B_Int_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/28 T=WORD") } record(longin, "PLC:LI08:1:COMPILE_DT_YEAR") { field(DESC, "Compile_Yr") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/32 T=BYTE") } record(longin, "PLC:LI08:1:COMPILE_DT_MONTH") { field(DESC, "Compile_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/33 T=BYTE") } record(longin, "PLC:LI08:1:COMPILE_DT_DAY") { field(DESC, "Compile_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/34 T=BYTE") } record(longin, "PLC:LI08:1:COMPILE_DT_HOUR") { field(DESC, "Compile_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/35 T=BYTE") } record(longin, "PLC:LI08:1:COMPILE_DT_MINUTE") { field(DESC, "Compile_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/36 T=BYTE") } record(longin, "PLC:LI08:1:COMPILE_DT_SECOND") { field(DESC, "Compile_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/37 T=BYTE") } record(longin, "PLC:LI08:1:OB100_DT_YEAR") { field(DESC, "Warm_Restart_Year") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/38 T=BYTE") } record(longin, "PLC:LI08:1:OB100_DT_MONTH") { field(DESC, "Warm_Restart_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/39 T=BYTE") } record(longin, "PLC:LI08:1:OB100_DT_DAY") { field(DESC, "Warm_Restart_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/40 T=BYTE") } record(longin, "PLC:LI08:1:OB100_DT_HOUR") { field(DESC, "Warm_Restart_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/41 T=BYTE") } record(longin, "PLC:LI08:1:OB100_DT_MINUTE") { field(DESC, "Warm_Restart_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/42 T=BYTE") } record(longin, "PLC:LI08:1:OB100_DT_SECOND") { field(DESC, "Warm_Restart_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/43 T=BYTE") } record(longin, "PLC:LI08:2A:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2A_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/44 T=WORD") } record(longin, "PLC:LI08:2B:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2B_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/46 T=WORD") } record(longin, "PLC:LI08:3A:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3A_Stop_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/158 T=WORD") } record(longin, "PLC:LI08:3B:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3B_Stop_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/162 T=WORD") } record(longin, "PLC:LI08:3A:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3A_Stop_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/166 T=WORD") } record(longin, "PLC:LI08:3B:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3B_Stop_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI08_PP01/168 T=WORD") } # This one is a bit different. Two PLCs have LI07/LI08 gate state, # but only 1-7 has lock state. record(calc, "PPS:LI08:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "PPS:LI08:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "PPS:LI08:1:Gate MS") field(INPB, "PPS:LI07:1:Locked MS") } record(mbbi, "PPS:LI08:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "PPS:LI08:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI08:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI08:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI08:1:Closed MS") field(INPB, "DOOR:LI08:1:Locked MS") } record(mbbi, "DOOR:LI08:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI08:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI09:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI09:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI09:1:Closed MS") field(INPB, "DOOR:LI09:1:Locked MS") } record(mbbi, "DOOR:LI09:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI09:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI10:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI10:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI10:1:Closed MS") field(INPB, "DOOR:LI10:1:Locked MS") } record(mbbi, "DOOR:LI10:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI10:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") }