record(bi, "PLC:LI01:1:S7_STATUS") { field(DTYP, "S7plc stat") field(INP, "@PLC_LI01_PP01") field(SCAN, "I/O Intr") field(ZNAM, "Disconnected") field(ONAM, "Connected") field(ZSV, "MAJOR") field(FLNK, "PLC:LI01:1:S7_STAT_COUNTER") } record(calc, "PLC:LI01:1:S7_STAT_COUNTER") { field(INPA, "PLC:LI01:1:S7_STAT_COUNTER") field(CALC, "A+1") field(FLNK, "PLC:LI01:1:S7_DISCONNECT_COUNTER") } record(calc, "PLC:LI01:1:S7_DISCONNECT_COUNTER") { field(INPA, "PLC:LI01:1:S7_STATUS") field(INPB, "PLC:LI01:1:S7_DISCONNECT_COUNTER.LA") field(INPC, "PLC:LI01:1:S7_DISCONNECT_COUNTER") field(CALC, "(A=0&&B=1)?C+1:C") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi7") { field(DESC, "Port LI01_BSOIC_Rd bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BSOC:LI01:1:HwEn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi7Valid") { field(INPA, "PLC:LI01:PP02:Bi7.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:HwEn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:HwEn_calc") { field(INPA, "PLC:LI01:PP02:Bi7 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi7Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:HwEn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:HwEn") { field(DESC, "BSOIC-HW_Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb7",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb7") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb7.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb7.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb7.FLNK","BSOC:LI01:1:HwEn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb7.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb7.VAL") #! Record("BSOC:LI01:1:HwEn_calc",260,18,0,1,"BSOC:LI01:1:HwEn_calc") #! Field("BSOC:LI01:1:HwEn_calc.INPA",16777215,0,"BSOC:LI01:1:HwEn_calc.INPA") #! Link("BSOC:LI01:1:HwEn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb7.VAL") #! Field("BSOC:LI01:1:HwEn_calc.INPB",16777215,1,"BSOC:LI01:1:HwEn_calc.INPB") #! Field("BSOC:LI01:1:HwEn_calc.OUT",16777215,1,"BSOC:LI01:1:HwEn_calc.OUT") #! Link("BSOC:LI01:1:HwEn_calc.OUT","BSOC:LI01:1:HwEn.VAL") #! Record("BSOC:LI01:1:HwEn",500,20,0,0,"BSOC:LI01:1:HwEn") #! Field("BSOC:LI01:1:HwEn.VAL",16777215,1,"BSOC:LI01:1:HwEn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi6") { field(DESC, "Port LI01_BSOIC_Rd bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI01:1:HwResetAll_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi6Valid") { field(INPA, "PLC:LI01:PP02:Bi6.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:HwResetAll_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:HwResetAll_calc") { field(INPA, "PLC:LI01:PP02:Bi6 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi6Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:HwResetAll PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:HwResetAll") { field(DESC, "BSOIC-HW_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb6",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb6") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb6.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb6.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb6.FLNK","BSOC:LI01:1:HwResetAll_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb6.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb6.VAL") #! Record("BSOC:LI01:1:HwResetAll_calc",260,18,0,1,"BSOC:LI01:1:HwResetAll_calc") #! Field("BSOC:LI01:1:HwResetAll_calc.INPA",16777215,0,"BSOC:LI01:1:HwResetAll_calc.INPA") #! Link("BSOC:LI01:1:HwResetAll_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb6.VAL") #! Field("BSOC:LI01:1:HwResetAll_calc.INPB",16777215,1,"BSOC:LI01:1:HwResetAll_calc.INPB") #! Field("BSOC:LI01:1:HwResetAll_calc.OUT",16777215,1,"BSOC:LI01:1:HwResetAll_calc.OUT") #! Link("BSOC:LI01:1:HwResetAll_calc.OUT","BSOC:LI01:1:HwResetAll.VAL") #! Record("BSOC:LI01:1:HwResetAll",500,20,0,0,"BSOC:LI01:1:HwResetAll") #! Field("BSOC:LI01:1:HwResetAll.VAL",16777215,1,"BSOC:LI01:1:HwResetAll.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi5") { field(DESC, "Port LI01_BSOIC_Rd bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI02:05:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi5Valid") { field(INPA, "PLC:LI01:PP02:Bi5.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:Eqp_calc") { field(INPA, "PLC:LI01:PP02:Bi5 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi5Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:Eqp") { field(DESC, "BSOIC-RT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb5",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb5") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb5.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb5.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb5.FLNK","BSOC:LI02:05:Eqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb5.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb5.VAL") #! Record("BSOC:LI02:05:Eqp_calc",260,18,0,1,"BSOC:LI02:05:Eqp_calc") #! Field("BSOC:LI02:05:Eqp_calc.INPA",16777215,0,"BSOC:LI02:05:Eqp_calc.INPA") #! Link("BSOC:LI02:05:Eqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb5.VAL") #! Field("BSOC:LI02:05:Eqp_calc.INPB",16777215,1,"BSOC:LI02:05:Eqp_calc.INPB") #! Field("BSOC:LI02:05:Eqp_calc.OUT",16777215,1,"BSOC:LI02:05:Eqp_calc.OUT") #! Link("BSOC:LI02:05:Eqp_calc.OUT","BSOC:LI02:05:Eqp.VAL") #! Record("BSOC:LI02:05:Eqp",500,20,0,0,"BSOC:LI02:05:Eqp") #! Field("BSOC:LI02:05:Eqp.VAL",16777215,1,"BSOC:LI02:05:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi4") { field(DESC, "Port LI01_BSOIC_Rd bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 4, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI02:05:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi4Valid") { field(INPA, "PLC:LI01:PP02:Bi4.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:Rad_calc") { field(INPA, "PLC:LI01:PP02:Bi4 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi4Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:Rad") { field(DESC, "BSOIC-RT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb4",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb4") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb4.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb4.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb4.FLNK","BSOC:LI02:05:Rad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb4.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb4.VAL") #! Record("BSOC:LI02:05:Rad_calc",260,18,0,1,"BSOC:LI02:05:Rad_calc") #! Field("BSOC:LI02:05:Rad_calc.INPA",16777215,0,"BSOC:LI02:05:Rad_calc.INPA") #! Link("BSOC:LI02:05:Rad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb4.VAL") #! Field("BSOC:LI02:05:Rad_calc.INPB",16777215,1,"BSOC:LI02:05:Rad_calc.INPB") #! Field("BSOC:LI02:05:Rad_calc.OUT",16777215,1,"BSOC:LI02:05:Rad_calc.OUT") #! Link("BSOC:LI02:05:Rad_calc.OUT","BSOC:LI02:05:Rad.VAL") #! Record("BSOC:LI02:05:Rad",500,20,0,0,"BSOC:LI02:05:Rad") #! Field("BSOC:LI02:05:Rad.VAL",16777215,1,"BSOC:LI02:05:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi3") { field(DESC, "Port LI01_BSOIC_Rd bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI02:05:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi3Valid") { field(INPA, "PLC:LI01:PP02:Bi3.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:HWBypass_calc") { field(INPA, "PLC:LI01:PP02:Bi3 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi3Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:HWBypass") { field(DESC, "BSOIC-RT_G1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb3",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb3") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb3.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb3.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb3.FLNK","BSOC:LI02:05:HWBypass_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb3.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb3.VAL") #! Record("BSOC:LI02:05:HWBypass_calc",260,18,0,1,"BSOC:LI02:05:HWBypass_calc") #! Field("BSOC:LI02:05:HWBypass_calc.INPA",16777215,0,"BSOC:LI02:05:HWBypass_calc.INPA") #! Link("BSOC:LI02:05:HWBypass_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb3.VAL") #! Field("BSOC:LI02:05:HWBypass_calc.INPB",16777215,1,"BSOC:LI02:05:HWBypass_calc.INPB") #! Field("BSOC:LI02:05:HWBypass_calc.OUT",16777215,1,"BSOC:LI02:05:HWBypass_calc.OUT") #! Link("BSOC:LI02:05:HWBypass_calc.OUT","BSOC:LI02:05:HWBypass.VAL") #! Record("BSOC:LI02:05:HWBypass",500,20,0,0,"BSOC:LI02:05:HWBypass") #! Field("BSOC:LI02:05:HWBypass.VAL",16777215,1,"BSOC:LI02:05:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi2") { field(DESC, "Port LI01_BSOIC_Rd bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G2:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi2Valid") { field(INPA, "PLC:LI01:PP02:Bi2.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:Eqp_calc") { field(INPA, "PLC:LI01:PP02:Bi2 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi2Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:Eqp") { field(DESC, "BSOIC-RT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb2",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb2") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb2.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb2.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb2.FLNK","BSOC:LI01:G2:Eqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb2.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb2.VAL") #! Record("BSOC:LI01:G2:Eqp_calc",260,18,0,1,"BSOC:LI01:G2:Eqp_calc") #! Field("BSOC:LI01:G2:Eqp_calc.INPA",16777215,0,"BSOC:LI01:G2:Eqp_calc.INPA") #! Link("BSOC:LI01:G2:Eqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb2.VAL") #! Field("BSOC:LI01:G2:Eqp_calc.INPB",16777215,1,"BSOC:LI01:G2:Eqp_calc.INPB") #! Field("BSOC:LI01:G2:Eqp_calc.OUT",16777215,1,"BSOC:LI01:G2:Eqp_calc.OUT") #! Link("BSOC:LI01:G2:Eqp_calc.OUT","BSOC:LI01:G2:Eqp.VAL") #! Record("BSOC:LI01:G2:Eqp",500,20,0,0,"BSOC:LI01:G2:Eqp") #! Field("BSOC:LI01:G2:Eqp.VAL",16777215,1,"BSOC:LI01:G2:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi1") { field(DESC, "Port LI01_BSOIC_Rd bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G2:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi1Valid") { field(INPA, "PLC:LI01:PP02:Bi1.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:Rad_calc") { field(INPA, "PLC:LI01:PP02:Bi1 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi1Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:Rad") { field(DESC, "BSOIC-RT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb1",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb1") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb1.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb1.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb1.FLNK","BSOC:LI01:G2:Rad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb1.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb1.VAL") #! Record("BSOC:LI01:G2:Rad_calc",260,18,0,1,"BSOC:LI01:G2:Rad_calc") #! Field("BSOC:LI01:G2:Rad_calc.INPA",16777215,0,"BSOC:LI01:G2:Rad_calc.INPA") #! Link("BSOC:LI01:G2:Rad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb1.VAL") #! Field("BSOC:LI01:G2:Rad_calc.INPB",16777215,1,"BSOC:LI01:G2:Rad_calc.INPB") #! Field("BSOC:LI01:G2:Rad_calc.OUT",16777215,1,"BSOC:LI01:G2:Rad_calc.OUT") #! Link("BSOC:LI01:G2:Rad_calc.OUT","BSOC:LI01:G2:Rad.VAL") #! Record("BSOC:LI01:G2:Rad",500,20,0,0,"BSOC:LI01:G2:Rad") #! Field("BSOC:LI01:G2:Rad.VAL",16777215,1,"BSOC:LI01:G2:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi0") { field(DESC, "Port LI01_BSOIC_Rd bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI01:G2:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi0Valid") { field(INPA, "PLC:LI01:PP02:Bi0.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:HWBypass_calc") { field(INPA, "PLC:LI01:PP02:Bi0 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi0Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:HWBypass") { field(DESC, "BSOIC-RT_G2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb0",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb0") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb0.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb0.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb0.FLNK","BSOC:LI01:G2:HWBypass_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb0.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb0.VAL") #! Record("BSOC:LI01:G2:HWBypass_calc",260,18,0,1,"BSOC:LI01:G2:HWBypass_calc") #! Field("BSOC:LI01:G2:HWBypass_calc.INPA",16777215,0,"BSOC:LI01:G2:HWBypass_calc.INPA") #! Link("BSOC:LI01:G2:HWBypass_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb0.VAL") #! Field("BSOC:LI01:G2:HWBypass_calc.INPB",16777215,1,"BSOC:LI01:G2:HWBypass_calc.INPB") #! Field("BSOC:LI01:G2:HWBypass_calc.OUT",16777215,1,"BSOC:LI01:G2:HWBypass_calc.OUT") #! Link("BSOC:LI01:G2:HWBypass_calc.OUT","BSOC:LI01:G2:HWBypass.VAL") #! Record("BSOC:LI01:G2:HWBypass",500,20,0,0,"BSOC:LI01:G2:HWBypass") #! Field("BSOC:LI01:G2:HWBypass.VAL",16777215,1,"BSOC:LI01:G2:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi15") { field(DESC, "Port LI01_BSOIC_Rd bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G3:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi15Valid") { field(INPA, "PLC:LI01:PP02:Bi15.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:Eqp_calc") { field(INPA, "PLC:LI01:PP02:Bi15 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi15Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:Eqp") { field(DESC, "BSOIC-RT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb15",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb15") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb15.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb15.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb15.FLNK","BSOC:LI01:G3:Eqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb15.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb15.VAL") #! Record("BSOC:LI01:G3:Eqp_calc",260,18,0,1,"BSOC:LI01:G3:Eqp_calc") #! Field("BSOC:LI01:G3:Eqp_calc.INPA",16777215,0,"BSOC:LI01:G3:Eqp_calc.INPA") #! Link("BSOC:LI01:G3:Eqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb15.VAL") #! Field("BSOC:LI01:G3:Eqp_calc.INPB",16777215,1,"BSOC:LI01:G3:Eqp_calc.INPB") #! Field("BSOC:LI01:G3:Eqp_calc.OUT",16777215,1,"BSOC:LI01:G3:Eqp_calc.OUT") #! Link("BSOC:LI01:G3:Eqp_calc.OUT","BSOC:LI01:G3:Eqp.VAL") #! Record("BSOC:LI01:G3:Eqp",500,20,0,0,"BSOC:LI01:G3:Eqp") #! Field("BSOC:LI01:G3:Eqp.VAL",16777215,1,"BSOC:LI01:G3:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi14") { field(DESC, "Port LI01_BSOIC_Rd bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G3:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi14Valid") { field(INPA, "PLC:LI01:PP02:Bi14.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:Rad_calc") { field(INPA, "PLC:LI01:PP02:Bi14 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi14Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:Rad") { field(DESC, "BSOIC-RT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb14",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb14") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb14.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb14.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb14.FLNK","BSOC:LI01:G3:Rad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb14.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb14.VAL") #! Record("BSOC:LI01:G3:Rad_calc",260,18,0,1,"BSOC:LI01:G3:Rad_calc") #! Field("BSOC:LI01:G3:Rad_calc.INPA",16777215,0,"BSOC:LI01:G3:Rad_calc.INPA") #! Link("BSOC:LI01:G3:Rad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb14.VAL") #! Field("BSOC:LI01:G3:Rad_calc.INPB",16777215,1,"BSOC:LI01:G3:Rad_calc.INPB") #! Field("BSOC:LI01:G3:Rad_calc.OUT",16777215,1,"BSOC:LI01:G3:Rad_calc.OUT") #! Link("BSOC:LI01:G3:Rad_calc.OUT","BSOC:LI01:G3:Rad.VAL") #! Record("BSOC:LI01:G3:Rad",500,20,0,0,"BSOC:LI01:G3:Rad") #! Field("BSOC:LI01:G3:Rad.VAL",16777215,1,"BSOC:LI01:G3:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi13") { field(DESC, "Port LI01_BSOIC_Rd bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 13, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI01:G3:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi13Valid") { field(INPA, "PLC:LI01:PP02:Bi13.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:HWBypass_calc") { field(INPA, "PLC:LI01:PP02:Bi13 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi13Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:HWBypass") { field(DESC, "BSOIC-RT_G3_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb13",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb13") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb13.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb13.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb13.FLNK","BSOC:LI01:G3:HWBypass_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb13.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb13.VAL") #! Record("BSOC:LI01:G3:HWBypass_calc",260,18,0,1,"BSOC:LI01:G3:HWBypass_calc") #! Field("BSOC:LI01:G3:HWBypass_calc.INPA",16777215,0,"BSOC:LI01:G3:HWBypass_calc.INPA") #! Link("BSOC:LI01:G3:HWBypass_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb13.VAL") #! Field("BSOC:LI01:G3:HWBypass_calc.INPB",16777215,1,"BSOC:LI01:G3:HWBypass_calc.INPB") #! Field("BSOC:LI01:G3:HWBypass_calc.OUT",16777215,1,"BSOC:LI01:G3:HWBypass_calc.OUT") #! Link("BSOC:LI01:G3:HWBypass_calc.OUT","BSOC:LI01:G3:HWBypass.VAL") #! Record("BSOC:LI01:G3:HWBypass",500,20,0,0,"BSOC:LI01:G3:HWBypass") #! Field("BSOC:LI01:G3:HWBypass.VAL",16777215,1,"BSOC:LI01:G3:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi12") { field(DESC, "Port LI01_BSOIC_Rd bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G4:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi12Valid") { field(INPA, "PLC:LI01:PP02:Bi12.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:Eqp_calc") { field(INPA, "PLC:LI01:PP02:Bi12 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi12Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:Eqp") { field(DESC, "BSOIC-RT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb12",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb12") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb12.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb12.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb12.FLNK","BSOC:LI01:G4:Eqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb12.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb12.VAL") #! Record("BSOC:LI01:G4:Eqp_calc",260,18,0,1,"BSOC:LI01:G4:Eqp_calc") #! Field("BSOC:LI01:G4:Eqp_calc.INPA",16777215,0,"BSOC:LI01:G4:Eqp_calc.INPA") #! Link("BSOC:LI01:G4:Eqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb12.VAL") #! Field("BSOC:LI01:G4:Eqp_calc.INPB",16777215,1,"BSOC:LI01:G4:Eqp_calc.INPB") #! Field("BSOC:LI01:G4:Eqp_calc.OUT",16777215,1,"BSOC:LI01:G4:Eqp_calc.OUT") #! Link("BSOC:LI01:G4:Eqp_calc.OUT","BSOC:LI01:G4:Eqp.VAL") #! Record("BSOC:LI01:G4:Eqp",500,20,0,0,"BSOC:LI01:G4:Eqp") #! Field("BSOC:LI01:G4:Eqp.VAL",16777215,1,"BSOC:LI01:G4:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi11") { field(DESC, "Port LI01_BSOIC_Rd bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G4:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi11Valid") { field(INPA, "PLC:LI01:PP02:Bi11.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:Rad_calc") { field(INPA, "PLC:LI01:PP02:Bi11 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi11Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:Rad") { field(DESC, "BSOIC-RT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb11",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb11") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb11.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb11.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb11.FLNK","BSOC:LI01:G4:Rad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb11.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb11.VAL") #! Record("BSOC:LI01:G4:Rad_calc",260,18,0,1,"BSOC:LI01:G4:Rad_calc") #! Field("BSOC:LI01:G4:Rad_calc.INPA",16777215,0,"BSOC:LI01:G4:Rad_calc.INPA") #! Link("BSOC:LI01:G4:Rad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb11.VAL") #! Field("BSOC:LI01:G4:Rad_calc.INPB",16777215,1,"BSOC:LI01:G4:Rad_calc.INPB") #! Field("BSOC:LI01:G4:Rad_calc.OUT",16777215,1,"BSOC:LI01:G4:Rad_calc.OUT") #! Link("BSOC:LI01:G4:Rad_calc.OUT","BSOC:LI01:G4:Rad.VAL") #! Record("BSOC:LI01:G4:Rad",500,20,0,0,"BSOC:LI01:G4:Rad") #! Field("BSOC:LI01:G4:Rad.VAL",16777215,1,"BSOC:LI01:G4:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi10") { field(DESC, "Port LI01_BSOIC_Rd bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 10, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI01:G4:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi10Valid") { field(INPA, "PLC:LI01:PP02:Bi10.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:HWBypass_calc") { field(INPA, "PLC:LI01:PP02:Bi10 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi10Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:HWBypass") { field(DESC, "BSOIC-RT_G4_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb10",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb10") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb10.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb10.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb10.FLNK","BSOC:LI01:G4:HWBypass_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb10.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb10.VAL") #! Record("BSOC:LI01:G4:HWBypass_calc",260,18,0,1,"BSOC:LI01:G4:HWBypass_calc") #! Field("BSOC:LI01:G4:HWBypass_calc.INPA",16777215,0,"BSOC:LI01:G4:HWBypass_calc.INPA") #! Link("BSOC:LI01:G4:HWBypass_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb10.VAL") #! Field("BSOC:LI01:G4:HWBypass_calc.INPB",16777215,1,"BSOC:LI01:G4:HWBypass_calc.INPB") #! Field("BSOC:LI01:G4:HWBypass_calc.OUT",16777215,1,"BSOC:LI01:G4:HWBypass_calc.OUT") #! Link("BSOC:LI01:G4:HWBypass_calc.OUT","BSOC:LI01:G4:HWBypass.VAL") #! Record("BSOC:LI01:G4:HWBypass",500,20,0,0,"BSOC:LI01:G4:HWBypass") #! Field("BSOC:LI01:G4:HWBypass.VAL",16777215,1,"BSOC:LI01:G4:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi9") { field(DESC, "Port LI01_BSOIC_Rd bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:N1:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi9Valid") { field(INPA, "PLC:LI01:PP02:Bi9.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N1:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N1:Rad_calc") { field(INPA, "PLC:LI01:PP02:Bi9 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi9Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N1:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N1:Rad") { field(DESC, "BSOIC-RT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb9",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb9") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb9.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb9.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb9.FLNK","BSOC:LI01:N1:Rad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb9.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb9.VAL") #! Record("BSOC:LI01:N1:Rad_calc",260,18,0,1,"BSOC:LI01:N1:Rad_calc") #! Field("BSOC:LI01:N1:Rad_calc.INPA",16777215,0,"BSOC:LI01:N1:Rad_calc.INPA") #! Link("BSOC:LI01:N1:Rad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb9.VAL") #! Field("BSOC:LI01:N1:Rad_calc.INPB",16777215,1,"BSOC:LI01:N1:Rad_calc.INPB") #! Field("BSOC:LI01:N1:Rad_calc.OUT",16777215,1,"BSOC:LI01:N1:Rad_calc.OUT") #! Link("BSOC:LI01:N1:Rad_calc.OUT","BSOC:LI01:N1:Rad.VAL") #! Record("BSOC:LI01:N1:Rad",500,20,0,0,"BSOC:LI01:N1:Rad") #! Field("BSOC:LI01:N1:Rad.VAL",16777215,1,"BSOC:LI01:N1:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi8") { field(DESC, "Port LI01_BSOIC_Rd bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 8, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI01:N1:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi8Valid") { field(INPA, "PLC:LI01:PP02:Bi8.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N1:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N1:HWBypass_calc") { field(INPA, "PLC:LI01:PP02:Bi8 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi8Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N1:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N1:HWBypass") { field(DESC, "BSOIC-RT_N1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb8",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb8") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb8.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb8.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb8.FLNK","BSOC:LI01:N1:HWBypass_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb8.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb8.VAL") #! Record("BSOC:LI01:N1:HWBypass_calc",260,18,0,1,"BSOC:LI01:N1:HWBypass_calc") #! Field("BSOC:LI01:N1:HWBypass_calc.INPA",16777215,0,"BSOC:LI01:N1:HWBypass_calc.INPA") #! Link("BSOC:LI01:N1:HWBypass_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb8.VAL") #! Field("BSOC:LI01:N1:HWBypass_calc.INPB",16777215,1,"BSOC:LI01:N1:HWBypass_calc.INPB") #! Field("BSOC:LI01:N1:HWBypass_calc.OUT",16777215,1,"BSOC:LI01:N1:HWBypass_calc.OUT") #! Link("BSOC:LI01:N1:HWBypass_calc.OUT","BSOC:LI01:N1:HWBypass.VAL") #! Record("BSOC:LI01:N1:HWBypass",500,20,0,0,"BSOC:LI01:N1:HWBypass") #! Field("BSOC:LI01:N1:HWBypass.VAL",16777215,1,"BSOC:LI01:N1:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi23") { field(DESC, "Port LI01_BSOIC_Rd bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:N2:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi23Valid") { field(INPA, "PLC:LI01:PP02:Bi23.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N2:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N2:Rad_calc") { field(INPA, "PLC:LI01:PP02:Bi23 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi23Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N2:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N2:Rad") { field(DESC, "BSOIC-RT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb23",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb23") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb23.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb23.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb23.FLNK","BSOC:LI01:N2:Rad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb23.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb23.VAL") #! Record("BSOC:LI01:N2:Rad_calc",260,18,0,1,"BSOC:LI01:N2:Rad_calc") #! Field("BSOC:LI01:N2:Rad_calc.INPA",16777215,0,"BSOC:LI01:N2:Rad_calc.INPA") #! Link("BSOC:LI01:N2:Rad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb23.VAL") #! Field("BSOC:LI01:N2:Rad_calc.INPB",16777215,1,"BSOC:LI01:N2:Rad_calc.INPB") #! Field("BSOC:LI01:N2:Rad_calc.OUT",16777215,1,"BSOC:LI01:N2:Rad_calc.OUT") #! Link("BSOC:LI01:N2:Rad_calc.OUT","BSOC:LI01:N2:Rad.VAL") #! Record("BSOC:LI01:N2:Rad",500,20,0,0,"BSOC:LI01:N2:Rad") #! Field("BSOC:LI01:N2:Rad.VAL",16777215,1,"BSOC:LI01:N2:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi22") { field(DESC, "Port LI01_BSOIC_Rd bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 22, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI01:N2:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi22Valid") { field(INPA, "PLC:LI01:PP02:Bi22.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N2:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N2:HWBypass_calc") { field(INPA, "PLC:LI01:PP02:Bi22 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi22Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N2:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N2:HWBypass") { field(DESC, "BSOIC-RT_N2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb22",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb22") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb22.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb22.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb22.FLNK","BSOC:LI01:N2:HWBypass_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb22.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb22.VAL") #! Record("BSOC:LI01:N2:HWBypass_calc",260,18,0,1,"BSOC:LI01:N2:HWBypass_calc") #! Field("BSOC:LI01:N2:HWBypass_calc.INPA",16777215,0,"BSOC:LI01:N2:HWBypass_calc.INPA") #! Link("BSOC:LI01:N2:HWBypass_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb22.VAL") #! Field("BSOC:LI01:N2:HWBypass_calc.INPB",16777215,1,"BSOC:LI01:N2:HWBypass_calc.INPB") #! Field("BSOC:LI01:N2:HWBypass_calc.OUT",16777215,1,"BSOC:LI01:N2:HWBypass_calc.OUT") #! Link("BSOC:LI01:N2:HWBypass_calc.OUT","BSOC:LI01:N2:HWBypass.VAL") #! Record("BSOC:LI01:N2:HWBypass",500,20,0,0,"BSOC:LI01:N2:HWBypass") #! Field("BSOC:LI01:N2:HWBypass.VAL",16777215,1,"BSOC:LI01:N2:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi21") { field(DESC, "Port LI01_BSOIC_Rd bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi21Valid") { field(INPA, "PLC:LI01:PP02:Bi21.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:CascIn_calc") { field(INPA, "PLC:LI01:PP02:Bi21 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi21Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb21",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb21") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb21.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb21.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb21.FLNK","BSOC:LI01:1:CascIn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb21.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb21.VAL") #! Record("BSOC:LI01:1:CascIn_calc",260,18,0,1,"BSOC:LI01:1:CascIn_calc") #! Field("BSOC:LI01:1:CascIn_calc.INPA",16777215,0,"BSOC:LI01:1:CascIn_calc.INPA") #! Link("BSOC:LI01:1:CascIn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb21.VAL") #! Field("BSOC:LI01:1:CascIn_calc.INPB",16777215,1,"BSOC:LI01:1:CascIn_calc.INPB") #! Field("BSOC:LI01:1:CascIn_calc.OUT",16777215,1,"BSOC:LI01:1:CascIn_calc.OUT") #! Link("BSOC:LI01:1:CascIn_calc.OUT","BSOC:LI01:1:CascIn.VAL") #! Record("BSOC:LI01:1:CascIn",500,20,0,0,"BSOC:LI01:1:CascIn") #! Field("BSOC:LI01:1:CascIn.VAL",16777215,1,"BSOC:LI01:1:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi20") { field(DESC, "Port LI01_BSOIC_Rd bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:2:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi20Valid") { field(INPA, "PLC:LI01:PP02:Bi20.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:2:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:2:CascIn_calc") { field(INPA, "PLC:LI01:PP02:Bi20 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi20Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:2:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:2:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb20",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb20") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb20.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb20.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb20.FLNK","BSOC:LI01:2:CascIn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb20.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb20.VAL") #! Record("BSOC:LI01:2:CascIn_calc",260,18,0,1,"BSOC:LI01:2:CascIn_calc") #! Field("BSOC:LI01:2:CascIn_calc.INPA",16777215,0,"BSOC:LI01:2:CascIn_calc.INPA") #! Link("BSOC:LI01:2:CascIn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb20.VAL") #! Field("BSOC:LI01:2:CascIn_calc.INPB",16777215,1,"BSOC:LI01:2:CascIn_calc.INPB") #! Field("BSOC:LI01:2:CascIn_calc.OUT",16777215,1,"BSOC:LI01:2:CascIn_calc.OUT") #! Link("BSOC:LI01:2:CascIn_calc.OUT","BSOC:LI01:2:CascIn.VAL") #! Record("BSOC:LI01:2:CascIn",500,20,0,0,"BSOC:LI01:2:CascIn") #! Field("BSOC:LI01:2:CascIn.VAL",16777215,1,"BSOC:LI01:2:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi19") { field(DESC, "Port LI01_BSOIC_Rd bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 19, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI02:05:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi19Valid") { field(INPA, "PLC:LI01:PP02:Bi19.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:SoRstRb_calc") { field(INPA, "PLC:LI01:PP02:Bi19 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi19Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:SoRstRb") { field(DESC, "BSOIC-G1_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb19",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb19") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb19.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb19.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb19.FLNK","BSOC:LI02:05:SoRstRb_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb19.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb19.VAL") #! Record("BSOC:LI02:05:SoRstRb_calc",260,18,0,1,"BSOC:LI02:05:SoRstRb_calc") #! Field("BSOC:LI02:05:SoRstRb_calc.INPA",16777215,0,"BSOC:LI02:05:SoRstRb_calc.INPA") #! Link("BSOC:LI02:05:SoRstRb_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb19.VAL") #! Field("BSOC:LI02:05:SoRstRb_calc.INPB",16777215,1,"BSOC:LI02:05:SoRstRb_calc.INPB") #! Field("BSOC:LI02:05:SoRstRb_calc.OUT",16777215,1,"BSOC:LI02:05:SoRstRb_calc.OUT") #! Link("BSOC:LI02:05:SoRstRb_calc.OUT","BSOC:LI02:05:SoRstRb.VAL") #! Record("BSOC:LI02:05:SoRstRb",500,20,0,0,"BSOC:LI02:05:SoRstRb") #! Field("BSOC:LI02:05:SoRstRb.VAL",16777215,1,"BSOC:LI02:05:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi18") { field(DESC, "Port LI01_BSOIC_Rd bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 18, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI01:G2:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi18Valid") { field(INPA, "PLC:LI01:PP02:Bi18.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:SoRstRb_calc") { field(INPA, "PLC:LI01:PP02:Bi18 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi18Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:SoRstRb") { field(DESC, "BSOIC-G2_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb18",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb18") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb18.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb18.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb18.FLNK","BSOC:LI01:G2:SoRstRb_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb18.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb18.VAL") #! Record("BSOC:LI01:G2:SoRstRb_calc",260,18,0,1,"BSOC:LI01:G2:SoRstRb_calc") #! Field("BSOC:LI01:G2:SoRstRb_calc.INPA",16777215,0,"BSOC:LI01:G2:SoRstRb_calc.INPA") #! Link("BSOC:LI01:G2:SoRstRb_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb18.VAL") #! Field("BSOC:LI01:G2:SoRstRb_calc.INPB",16777215,1,"BSOC:LI01:G2:SoRstRb_calc.INPB") #! Field("BSOC:LI01:G2:SoRstRb_calc.OUT",16777215,1,"BSOC:LI01:G2:SoRstRb_calc.OUT") #! Link("BSOC:LI01:G2:SoRstRb_calc.OUT","BSOC:LI01:G2:SoRstRb.VAL") #! Record("BSOC:LI01:G2:SoRstRb",500,20,0,0,"BSOC:LI01:G2:SoRstRb") #! Field("BSOC:LI01:G2:SoRstRb.VAL",16777215,1,"BSOC:LI01:G2:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi17") { field(DESC, "Port LI01_BSOIC_Rd bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 17, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI01:G3:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi17Valid") { field(INPA, "PLC:LI01:PP02:Bi17.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:SoRstRb_calc") { field(INPA, "PLC:LI01:PP02:Bi17 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi17Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:SoRstRb") { field(DESC, "BSOIC-G3_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb17",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb17") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb17.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb17.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb17.FLNK","BSOC:LI01:G3:SoRstRb_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb17.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb17.VAL") #! Record("BSOC:LI01:G3:SoRstRb_calc",260,18,0,1,"BSOC:LI01:G3:SoRstRb_calc") #! Field("BSOC:LI01:G3:SoRstRb_calc.INPA",16777215,0,"BSOC:LI01:G3:SoRstRb_calc.INPA") #! Link("BSOC:LI01:G3:SoRstRb_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb17.VAL") #! Field("BSOC:LI01:G3:SoRstRb_calc.INPB",16777215,1,"BSOC:LI01:G3:SoRstRb_calc.INPB") #! Field("BSOC:LI01:G3:SoRstRb_calc.OUT",16777215,1,"BSOC:LI01:G3:SoRstRb_calc.OUT") #! Link("BSOC:LI01:G3:SoRstRb_calc.OUT","BSOC:LI01:G3:SoRstRb.VAL") #! Record("BSOC:LI01:G3:SoRstRb",500,20,0,0,"BSOC:LI01:G3:SoRstRb") #! Field("BSOC:LI01:G3:SoRstRb.VAL",16777215,1,"BSOC:LI01:G3:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi16") { field(DESC, "Port LI01_BSOIC_Rd bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 16, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI01:G4:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi16Valid") { field(INPA, "PLC:LI01:PP02:Bi16.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:SoRstRb_calc") { field(INPA, "PLC:LI01:PP02:Bi16 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi16Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:SoRstRb") { field(DESC, "BSOIC-G4_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb16",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb16") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb16.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb16.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb16.FLNK","BSOC:LI01:G4:SoRstRb_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb16.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb16.VAL") #! Record("BSOC:LI01:G4:SoRstRb_calc",260,18,0,1,"BSOC:LI01:G4:SoRstRb_calc") #! Field("BSOC:LI01:G4:SoRstRb_calc.INPA",16777215,0,"BSOC:LI01:G4:SoRstRb_calc.INPA") #! Link("BSOC:LI01:G4:SoRstRb_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb16.VAL") #! Field("BSOC:LI01:G4:SoRstRb_calc.INPB",16777215,1,"BSOC:LI01:G4:SoRstRb_calc.INPB") #! Field("BSOC:LI01:G4:SoRstRb_calc.OUT",16777215,1,"BSOC:LI01:G4:SoRstRb_calc.OUT") #! Link("BSOC:LI01:G4:SoRstRb_calc.OUT","BSOC:LI01:G4:SoRstRb.VAL") #! Record("BSOC:LI01:G4:SoRstRb",500,20,0,0,"BSOC:LI01:G4:SoRstRb") #! Field("BSOC:LI01:G4:SoRstRb.VAL",16777215,1,"BSOC:LI01:G4:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi95") { field(DESC, "Port LI01_BSOIC_Rd bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 95, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI01:1:AnnAlarm_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi95Valid") { field(INPA, "PLC:LI01:PP02:Bi95.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:AnnAlarm_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:AnnAlarm_calc") { field(INPA, "PLC:LI01:PP02:Bi95 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi95Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:AnnAlarm PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:AnnAlarm") { field(DESC, "BSOIC-HW_Annunciator_Alarm") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb95",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb95") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb95.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb95.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb95.FLNK","BSOC:LI01:1:AnnAlarm_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb95.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb95.VAL") #! Record("BSOC:LI01:1:AnnAlarm_calc",260,18,0,1,"BSOC:LI01:1:AnnAlarm_calc") #! Field("BSOC:LI01:1:AnnAlarm_calc.INPA",16777215,0,"BSOC:LI01:1:AnnAlarm_calc.INPA") #! Link("BSOC:LI01:1:AnnAlarm_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb95.VAL") #! Field("BSOC:LI01:1:AnnAlarm_calc.INPB",16777215,1,"BSOC:LI01:1:AnnAlarm_calc.INPB") #! Field("BSOC:LI01:1:AnnAlarm_calc.OUT",16777215,1,"BSOC:LI01:1:AnnAlarm_calc.OUT") #! Link("BSOC:LI01:1:AnnAlarm_calc.OUT","BSOC:LI01:1:AnnAlarm.VAL") #! Record("BSOC:LI01:1:AnnAlarm",500,20,0,0,"BSOC:LI01:1:AnnAlarm") #! Field("BSOC:LI01:1:AnnAlarm.VAL",16777215,1,"BSOC:LI01:1:AnnAlarm.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi94") { field(DESC, "Port LI01_BSOIC_Rd bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 94, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI01:1:CascOut_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi94Valid") { field(INPA, "PLC:LI01:PP02:Bi94.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:CascOut_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:CascOut_calc") { field(INPA, "PLC:LI01:PP02:Bi94 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi94Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:CascOut PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:CascOut") { field(DESC, "BSOIC-HW_Cascade_Out") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb94",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb94") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb94.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb94.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb94.FLNK","BSOC:LI01:1:CascOut_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb94.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb94.VAL") #! Record("BSOC:LI01:1:CascOut_calc",260,18,0,1,"BSOC:LI01:1:CascOut_calc") #! Field("BSOC:LI01:1:CascOut_calc.INPA",16777215,0,"BSOC:LI01:1:CascOut_calc.INPA") #! Link("BSOC:LI01:1:CascOut_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb94.VAL") #! Field("BSOC:LI01:1:CascOut_calc.INPB",16777215,1,"BSOC:LI01:1:CascOut_calc.INPB") #! Field("BSOC:LI01:1:CascOut_calc.OUT",16777215,1,"BSOC:LI01:1:CascOut_calc.OUT") #! Link("BSOC:LI01:1:CascOut_calc.OUT","BSOC:LI01:1:CascOut.VAL") #! Record("BSOC:LI01:1:CascOut",500,20,0,0,"BSOC:LI01:1:CascOut") #! Field("BSOC:LI01:1:CascOut.VAL",16777215,1,"BSOC:LI01:1:CascOut.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi93") { field(DESC, "Port LI01_BSOIC_Rd bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:HWSfOut1_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi93Valid") { field(INPA, "PLC:LI01:PP02:Bi93.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:HWSfOut1_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:HWSfOut1_calc") { field(INPA, "PLC:LI01:PP02:Bi93 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi93Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:HWSfOut1 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:HWSfOut1") { field(DESC, "BSOIC-HW_Safety_Out1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb93",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb93") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb93.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb93.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb93.FLNK","BSOC:LI01:1:HWSfOut1_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb93.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb93.VAL") #! Record("BSOC:LI01:1:HWSfOut1_calc",260,18,0,1,"BSOC:LI01:1:HWSfOut1_calc") #! Field("BSOC:LI01:1:HWSfOut1_calc.INPA",16777215,0,"BSOC:LI01:1:HWSfOut1_calc.INPA") #! Link("BSOC:LI01:1:HWSfOut1_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb93.VAL") #! Field("BSOC:LI01:1:HWSfOut1_calc.INPB",16777215,1,"BSOC:LI01:1:HWSfOut1_calc.INPB") #! Field("BSOC:LI01:1:HWSfOut1_calc.OUT",16777215,1,"BSOC:LI01:1:HWSfOut1_calc.OUT") #! Link("BSOC:LI01:1:HWSfOut1_calc.OUT","BSOC:LI01:1:HWSfOut1.VAL") #! Record("BSOC:LI01:1:HWSfOut1",500,20,0,0,"BSOC:LI01:1:HWSfOut1") #! Field("BSOC:LI01:1:HWSfOut1.VAL",16777215,1,"BSOC:LI01:1:HWSfOut1.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi92") { field(DESC, "Port LI01_BSOIC_Rd bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:HWSfOut2_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi92Valid") { field(INPA, "PLC:LI01:PP02:Bi92.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:HWSfOut2_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:HWSfOut2_calc") { field(INPA, "PLC:LI01:PP02:Bi92 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi92Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:HWSfOut2 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:HWSfOut2") { field(DESC, "BSOIC-HW_Safety_Out2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb92",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb92") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb92.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb92.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb92.FLNK","BSOC:LI01:1:HWSfOut2_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb92.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb92.VAL") #! Record("BSOC:LI01:1:HWSfOut2_calc",260,18,0,1,"BSOC:LI01:1:HWSfOut2_calc") #! Field("BSOC:LI01:1:HWSfOut2_calc.INPA",16777215,0,"BSOC:LI01:1:HWSfOut2_calc.INPA") #! Link("BSOC:LI01:1:HWSfOut2_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb92.VAL") #! Field("BSOC:LI01:1:HWSfOut2_calc.INPB",16777215,1,"BSOC:LI01:1:HWSfOut2_calc.INPB") #! Field("BSOC:LI01:1:HWSfOut2_calc.OUT",16777215,1,"BSOC:LI01:1:HWSfOut2_calc.OUT") #! Link("BSOC:LI01:1:HWSfOut2_calc.OUT","BSOC:LI01:1:HWSfOut2.VAL") #! Record("BSOC:LI01:1:HWSfOut2",500,20,0,0,"BSOC:LI01:1:HWSfOut2") #! Field("BSOC:LI01:1:HWSfOut2.VAL",16777215,1,"BSOC:LI01:1:HWSfOut2.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi91") { field(DESC, "Port LI01_BSOIC_Rd bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:HWSfOut3_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi91Valid") { field(INPA, "PLC:LI01:PP02:Bi91.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:HWSfOut3_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:HWSfOut3_calc") { field(INPA, "PLC:LI01:PP02:Bi91 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi91Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:HWSfOut3 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:HWSfOut3") { field(DESC, "BSOIC-HW_Safety_Out3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb91",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb91") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb91.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb91.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb91.FLNK","BSOC:LI01:1:HWSfOut3_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb91.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb91.VAL") #! Record("BSOC:LI01:1:HWSfOut3_calc",260,18,0,1,"BSOC:LI01:1:HWSfOut3_calc") #! Field("BSOC:LI01:1:HWSfOut3_calc.INPA",16777215,0,"BSOC:LI01:1:HWSfOut3_calc.INPA") #! Link("BSOC:LI01:1:HWSfOut3_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb91.VAL") #! Field("BSOC:LI01:1:HWSfOut3_calc.INPB",16777215,1,"BSOC:LI01:1:HWSfOut3_calc.INPB") #! Field("BSOC:LI01:1:HWSfOut3_calc.OUT",16777215,1,"BSOC:LI01:1:HWSfOut3_calc.OUT") #! Link("BSOC:LI01:1:HWSfOut3_calc.OUT","BSOC:LI01:1:HWSfOut3.VAL") #! Record("BSOC:LI01:1:HWSfOut3",500,20,0,0,"BSOC:LI01:1:HWSfOut3") #! Field("BSOC:LI01:1:HWSfOut3.VAL",16777215,1,"BSOC:LI01:1:HWSfOut3.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi90") { field(DESC, "Port LI01_BSOIC_Rd bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:HWSfOut4_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi90Valid") { field(INPA, "PLC:LI01:PP02:Bi90.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:HWSfOut4_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:HWSfOut4_calc") { field(INPA, "PLC:LI01:PP02:Bi90 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi90Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:HWSfOut4 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:HWSfOut4") { field(DESC, "BSOIC-HW_Safety_Out4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb90",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb90") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb90.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb90.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb90.FLNK","BSOC:LI01:1:HWSfOut4_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb90.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb90.VAL") #! Record("BSOC:LI01:1:HWSfOut4_calc",260,18,0,1,"BSOC:LI01:1:HWSfOut4_calc") #! Field("BSOC:LI01:1:HWSfOut4_calc.INPA",16777215,0,"BSOC:LI01:1:HWSfOut4_calc.INPA") #! Link("BSOC:LI01:1:HWSfOut4_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb90.VAL") #! Field("BSOC:LI01:1:HWSfOut4_calc.INPB",16777215,1,"BSOC:LI01:1:HWSfOut4_calc.INPB") #! Field("BSOC:LI01:1:HWSfOut4_calc.OUT",16777215,1,"BSOC:LI01:1:HWSfOut4_calc.OUT") #! Link("BSOC:LI01:1:HWSfOut4_calc.OUT","BSOC:LI01:1:HWSfOut4.VAL") #! Record("BSOC:LI01:1:HWSfOut4",500,20,0,0,"BSOC:LI01:1:HWSfOut4") #! Field("BSOC:LI01:1:HWSfOut4.VAL",16777215,1,"BSOC:LI01:1:HWSfOut4.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi89") { field(DESC, "Port LI01_BSOIC_Rd bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI02:05:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi89Valid") { field(INPA, "PLC:LI01:PP02:Bi89.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:LatEqp_calc") { field(INPA, "PLC:LI01:PP02:Bi89 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi89Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:LatEqp") { field(DESC, "BSOIC-LAT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb89",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb89") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb89.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb89.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb89.FLNK","BSOC:LI02:05:LatEqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb89.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb89.VAL") #! Record("BSOC:LI02:05:LatEqp_calc",260,18,0,1,"BSOC:LI02:05:LatEqp_calc") #! Field("BSOC:LI02:05:LatEqp_calc.INPA",16777215,0,"BSOC:LI02:05:LatEqp_calc.INPA") #! Link("BSOC:LI02:05:LatEqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb89.VAL") #! Field("BSOC:LI02:05:LatEqp_calc.INPB",16777215,1,"BSOC:LI02:05:LatEqp_calc.INPB") #! Field("BSOC:LI02:05:LatEqp_calc.OUT",16777215,1,"BSOC:LI02:05:LatEqp_calc.OUT") #! Link("BSOC:LI02:05:LatEqp_calc.OUT","BSOC:LI02:05:LatEqp.VAL") #! Record("BSOC:LI02:05:LatEqp",500,20,0,0,"BSOC:LI02:05:LatEqp") #! Field("BSOC:LI02:05:LatEqp.VAL",16777215,1,"BSOC:LI02:05:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi88") { field(DESC, "Port LI01_BSOIC_Rd bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI02:05:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi88Valid") { field(INPA, "PLC:LI01:PP02:Bi88.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:LatRad_calc") { field(INPA, "PLC:LI01:PP02:Bi88 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi88Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:LatRad") { field(DESC, "BSOIC-LAT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb88",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb88") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb88.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb88.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb88.FLNK","BSOC:LI02:05:LatRad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb88.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb88.VAL") #! Record("BSOC:LI02:05:LatRad_calc",260,18,0,1,"BSOC:LI02:05:LatRad_calc") #! Field("BSOC:LI02:05:LatRad_calc.INPA",16777215,0,"BSOC:LI02:05:LatRad_calc.INPA") #! Link("BSOC:LI02:05:LatRad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb88.VAL") #! Field("BSOC:LI02:05:LatRad_calc.INPB",16777215,1,"BSOC:LI02:05:LatRad_calc.INPB") #! Field("BSOC:LI02:05:LatRad_calc.OUT",16777215,1,"BSOC:LI02:05:LatRad_calc.OUT") #! Link("BSOC:LI02:05:LatRad_calc.OUT","BSOC:LI02:05:LatRad.VAL") #! Record("BSOC:LI02:05:LatRad",500,20,0,0,"BSOC:LI02:05:LatRad") #! Field("BSOC:LI02:05:LatRad.VAL",16777215,1,"BSOC:LI02:05:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi103") { field(DESC, "Port LI01_BSOIC_Rd bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G2:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi103Valid") { field(INPA, "PLC:LI01:PP02:Bi103.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:LatEqp_calc") { field(INPA, "PLC:LI01:PP02:Bi103 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi103Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:LatEqp") { field(DESC, "BSOIC-LAT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb103",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb103") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb103.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb103.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb103.FLNK","BSOC:LI01:G2:LatEqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb103.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb103.VAL") #! Record("BSOC:LI01:G2:LatEqp_calc",260,18,0,1,"BSOC:LI01:G2:LatEqp_calc") #! Field("BSOC:LI01:G2:LatEqp_calc.INPA",16777215,0,"BSOC:LI01:G2:LatEqp_calc.INPA") #! Link("BSOC:LI01:G2:LatEqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb103.VAL") #! Field("BSOC:LI01:G2:LatEqp_calc.INPB",16777215,1,"BSOC:LI01:G2:LatEqp_calc.INPB") #! Field("BSOC:LI01:G2:LatEqp_calc.OUT",16777215,1,"BSOC:LI01:G2:LatEqp_calc.OUT") #! Link("BSOC:LI01:G2:LatEqp_calc.OUT","BSOC:LI01:G2:LatEqp.VAL") #! Record("BSOC:LI01:G2:LatEqp",500,20,0,0,"BSOC:LI01:G2:LatEqp") #! Field("BSOC:LI01:G2:LatEqp.VAL",16777215,1,"BSOC:LI01:G2:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi102") { field(DESC, "Port LI01_BSOIC_Rd bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G2:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi102Valid") { field(INPA, "PLC:LI01:PP02:Bi102.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:LatRad_calc") { field(INPA, "PLC:LI01:PP02:Bi102 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi102Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:LatRad") { field(DESC, "BSOIC-LAT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb102",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb102") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb102.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb102.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb102.FLNK","BSOC:LI01:G2:LatRad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb102.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb102.VAL") #! Record("BSOC:LI01:G2:LatRad_calc",260,18,0,1,"BSOC:LI01:G2:LatRad_calc") #! Field("BSOC:LI01:G2:LatRad_calc.INPA",16777215,0,"BSOC:LI01:G2:LatRad_calc.INPA") #! Link("BSOC:LI01:G2:LatRad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb102.VAL") #! Field("BSOC:LI01:G2:LatRad_calc.INPB",16777215,1,"BSOC:LI01:G2:LatRad_calc.INPB") #! Field("BSOC:LI01:G2:LatRad_calc.OUT",16777215,1,"BSOC:LI01:G2:LatRad_calc.OUT") #! Link("BSOC:LI01:G2:LatRad_calc.OUT","BSOC:LI01:G2:LatRad.VAL") #! Record("BSOC:LI01:G2:LatRad",500,20,0,0,"BSOC:LI01:G2:LatRad") #! Field("BSOC:LI01:G2:LatRad.VAL",16777215,1,"BSOC:LI01:G2:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi101") { field(DESC, "Port LI01_BSOIC_Rd bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G3:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi101Valid") { field(INPA, "PLC:LI01:PP02:Bi101.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:LatEqp_calc") { field(INPA, "PLC:LI01:PP02:Bi101 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi101Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:LatEqp") { field(DESC, "BSOIC-LAT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb101",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb101") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb101.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb101.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb101.FLNK","BSOC:LI01:G3:LatEqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb101.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb101.VAL") #! Record("BSOC:LI01:G3:LatEqp_calc",260,18,0,1,"BSOC:LI01:G3:LatEqp_calc") #! Field("BSOC:LI01:G3:LatEqp_calc.INPA",16777215,0,"BSOC:LI01:G3:LatEqp_calc.INPA") #! Link("BSOC:LI01:G3:LatEqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb101.VAL") #! Field("BSOC:LI01:G3:LatEqp_calc.INPB",16777215,1,"BSOC:LI01:G3:LatEqp_calc.INPB") #! Field("BSOC:LI01:G3:LatEqp_calc.OUT",16777215,1,"BSOC:LI01:G3:LatEqp_calc.OUT") #! Link("BSOC:LI01:G3:LatEqp_calc.OUT","BSOC:LI01:G3:LatEqp.VAL") #! Record("BSOC:LI01:G3:LatEqp",500,20,0,0,"BSOC:LI01:G3:LatEqp") #! Field("BSOC:LI01:G3:LatEqp.VAL",16777215,1,"BSOC:LI01:G3:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi100") { field(DESC, "Port LI01_BSOIC_Rd bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G3:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi100Valid") { field(INPA, "PLC:LI01:PP02:Bi100.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:LatRad_calc") { field(INPA, "PLC:LI01:PP02:Bi100 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi100Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:LatRad") { field(DESC, "BSOIC-LAT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb100",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb100") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb100.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb100.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb100.FLNK","BSOC:LI01:G3:LatRad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb100.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb100.VAL") #! Record("BSOC:LI01:G3:LatRad_calc",260,18,0,1,"BSOC:LI01:G3:LatRad_calc") #! Field("BSOC:LI01:G3:LatRad_calc.INPA",16777215,0,"BSOC:LI01:G3:LatRad_calc.INPA") #! Link("BSOC:LI01:G3:LatRad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb100.VAL") #! Field("BSOC:LI01:G3:LatRad_calc.INPB",16777215,1,"BSOC:LI01:G3:LatRad_calc.INPB") #! Field("BSOC:LI01:G3:LatRad_calc.OUT",16777215,1,"BSOC:LI01:G3:LatRad_calc.OUT") #! Link("BSOC:LI01:G3:LatRad_calc.OUT","BSOC:LI01:G3:LatRad.VAL") #! Record("BSOC:LI01:G3:LatRad",500,20,0,0,"BSOC:LI01:G3:LatRad") #! Field("BSOC:LI01:G3:LatRad.VAL",16777215,1,"BSOC:LI01:G3:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi99") { field(DESC, "Port LI01_BSOIC_Rd bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G4:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi99Valid") { field(INPA, "PLC:LI01:PP02:Bi99.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:LatEqp_calc") { field(INPA, "PLC:LI01:PP02:Bi99 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi99Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:LatEqp") { field(DESC, "BSOIC-LAT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb99",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb99") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb99.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb99.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb99.FLNK","BSOC:LI01:G4:LatEqp_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb99.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb99.VAL") #! Record("BSOC:LI01:G4:LatEqp_calc",260,18,0,1,"BSOC:LI01:G4:LatEqp_calc") #! Field("BSOC:LI01:G4:LatEqp_calc.INPA",16777215,0,"BSOC:LI01:G4:LatEqp_calc.INPA") #! Link("BSOC:LI01:G4:LatEqp_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb99.VAL") #! Field("BSOC:LI01:G4:LatEqp_calc.INPB",16777215,1,"BSOC:LI01:G4:LatEqp_calc.INPB") #! Field("BSOC:LI01:G4:LatEqp_calc.OUT",16777215,1,"BSOC:LI01:G4:LatEqp_calc.OUT") #! Link("BSOC:LI01:G4:LatEqp_calc.OUT","BSOC:LI01:G4:LatEqp.VAL") #! Record("BSOC:LI01:G4:LatEqp",500,20,0,0,"BSOC:LI01:G4:LatEqp") #! Field("BSOC:LI01:G4:LatEqp.VAL",16777215,1,"BSOC:LI01:G4:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi98") { field(DESC, "Port LI01_BSOIC_Rd bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G4:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi98Valid") { field(INPA, "PLC:LI01:PP02:Bi98.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:LatRad_calc") { field(INPA, "PLC:LI01:PP02:Bi98 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi98Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:LatRad") { field(DESC, "BSOIC-LAT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb98",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb98") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb98.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb98.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb98.FLNK","BSOC:LI01:G4:LatRad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb98.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb98.VAL") #! Record("BSOC:LI01:G4:LatRad_calc",260,18,0,1,"BSOC:LI01:G4:LatRad_calc") #! Field("BSOC:LI01:G4:LatRad_calc.INPA",16777215,0,"BSOC:LI01:G4:LatRad_calc.INPA") #! Link("BSOC:LI01:G4:LatRad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb98.VAL") #! Field("BSOC:LI01:G4:LatRad_calc.INPB",16777215,1,"BSOC:LI01:G4:LatRad_calc.INPB") #! Field("BSOC:LI01:G4:LatRad_calc.OUT",16777215,1,"BSOC:LI01:G4:LatRad_calc.OUT") #! Link("BSOC:LI01:G4:LatRad_calc.OUT","BSOC:LI01:G4:LatRad.VAL") #! Record("BSOC:LI01:G4:LatRad",500,20,0,0,"BSOC:LI01:G4:LatRad") #! Field("BSOC:LI01:G4:LatRad.VAL",16777215,1,"BSOC:LI01:G4:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi97") { field(DESC, "Port LI01_BSOIC_Rd bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:N1:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi97Valid") { field(INPA, "PLC:LI01:PP02:Bi97.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N1:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N1:LatRad_calc") { field(INPA, "PLC:LI01:PP02:Bi97 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi97Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N1:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N1:LatRad") { field(DESC, "BSOIC-LAT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb97",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb97") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb97.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb97.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb97.FLNK","BSOC:LI01:N1:LatRad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb97.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb97.VAL") #! Record("BSOC:LI01:N1:LatRad_calc",260,18,0,1,"BSOC:LI01:N1:LatRad_calc") #! Field("BSOC:LI01:N1:LatRad_calc.INPA",16777215,0,"BSOC:LI01:N1:LatRad_calc.INPA") #! Link("BSOC:LI01:N1:LatRad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb97.VAL") #! Field("BSOC:LI01:N1:LatRad_calc.INPB",16777215,1,"BSOC:LI01:N1:LatRad_calc.INPB") #! Field("BSOC:LI01:N1:LatRad_calc.OUT",16777215,1,"BSOC:LI01:N1:LatRad_calc.OUT") #! Link("BSOC:LI01:N1:LatRad_calc.OUT","BSOC:LI01:N1:LatRad.VAL") #! Record("BSOC:LI01:N1:LatRad",500,20,0,0,"BSOC:LI01:N1:LatRad") #! Field("BSOC:LI01:N1:LatRad.VAL",16777215,1,"BSOC:LI01:N1:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi96") { field(DESC, "Port LI01_BSOIC_Rd bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:N2:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi96Valid") { field(INPA, "PLC:LI01:PP02:Bi96.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N2:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N2:LatRad_calc") { field(INPA, "PLC:LI01:PP02:Bi96 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi96Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N2:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N2:LatRad") { field(DESC, "BSOIC-LAT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb96",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb96") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb96.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb96.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb96.FLNK","BSOC:LI01:N2:LatRad_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb96.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb96.VAL") #! Record("BSOC:LI01:N2:LatRad_calc",260,18,0,1,"BSOC:LI01:N2:LatRad_calc") #! Field("BSOC:LI01:N2:LatRad_calc.INPA",16777215,0,"BSOC:LI01:N2:LatRad_calc.INPA") #! Link("BSOC:LI01:N2:LatRad_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb96.VAL") #! Field("BSOC:LI01:N2:LatRad_calc.INPB",16777215,1,"BSOC:LI01:N2:LatRad_calc.INPB") #! Field("BSOC:LI01:N2:LatRad_calc.OUT",16777215,1,"BSOC:LI01:N2:LatRad_calc.OUT") #! Link("BSOC:LI01:N2:LatRad_calc.OUT","BSOC:LI01:N2:LatRad.VAL") #! Record("BSOC:LI01:N2:LatRad",500,20,0,0,"BSOC:LI01:N2:LatRad") #! Field("BSOC:LI01:N2:LatRad.VAL",16777215,1,"BSOC:LI01:N2:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi111") { field(DESC, "Port LI01_BSOIC_Rd bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi111Valid") { field(INPA, "PLC:LI01:PP02:Bi111.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:LatCascIn_calc") { field(INPA, "PLC:LI01:PP02:Bi111 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi111Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb111",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb111") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb111.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb111.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb111.FLNK","BSOC:LI01:1:LatCascIn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb111.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb111.VAL") #! Record("BSOC:LI01:1:LatCascIn_calc",260,18,0,1,"BSOC:LI01:1:LatCascIn_calc") #! Field("BSOC:LI01:1:LatCascIn_calc.INPA",16777215,0,"BSOC:LI01:1:LatCascIn_calc.INPA") #! Link("BSOC:LI01:1:LatCascIn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb111.VAL") #! Field("BSOC:LI01:1:LatCascIn_calc.INPB",16777215,1,"BSOC:LI01:1:LatCascIn_calc.INPB") #! Field("BSOC:LI01:1:LatCascIn_calc.OUT",16777215,1,"BSOC:LI01:1:LatCascIn_calc.OUT") #! Link("BSOC:LI01:1:LatCascIn_calc.OUT","BSOC:LI01:1:LatCascIn.VAL") #! Record("BSOC:LI01:1:LatCascIn",500,20,0,0,"BSOC:LI01:1:LatCascIn") #! Field("BSOC:LI01:1:LatCascIn.VAL",16777215,1,"BSOC:LI01:1:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi110") { field(DESC, "Port LI01_BSOIC_Rd bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:2:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi110Valid") { field(INPA, "PLC:LI01:PP02:Bi110.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:2:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:2:LatCascIn_calc") { field(INPA, "PLC:LI01:PP02:Bi110 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi110Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:2:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:2:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb110",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb110") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb110.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb110.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb110.FLNK","BSOC:LI01:2:LatCascIn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb110.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb110.VAL") #! Record("BSOC:LI01:2:LatCascIn_calc",260,18,0,1,"BSOC:LI01:2:LatCascIn_calc") #! Field("BSOC:LI01:2:LatCascIn_calc.INPA",16777215,0,"BSOC:LI01:2:LatCascIn_calc.INPA") #! Link("BSOC:LI01:2:LatCascIn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb110.VAL") #! Field("BSOC:LI01:2:LatCascIn_calc.INPB",16777215,1,"BSOC:LI01:2:LatCascIn_calc.INPB") #! Field("BSOC:LI01:2:LatCascIn_calc.OUT",16777215,1,"BSOC:LI01:2:LatCascIn_calc.OUT") #! Link("BSOC:LI01:2:LatCascIn_calc.OUT","BSOC:LI01:2:LatCascIn.VAL") #! Record("BSOC:LI01:2:LatCascIn",500,20,0,0,"BSOC:LI01:2:LatCascIn") #! Field("BSOC:LI01:2:LatCascIn.VAL",16777215,1,"BSOC:LI01:2:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi109") { field(DESC, "Port LI01_BSOIC_Rd bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:AllGOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi109Valid") { field(INPA, "PLC:LI01:PP02:Bi109.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:AllGOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:AllGOk_calc") { field(INPA, "PLC:LI01:PP02:Bi109 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi109Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:AllGOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:AllGOk") { field(DESC, "BSOIC-All_Gamma_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb109",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb109") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb109.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb109.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb109.FLNK","BSOC:LI01:1:AllGOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb109.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb109.VAL") #! Record("BSOC:LI01:1:AllGOk_calc",260,18,0,1,"BSOC:LI01:1:AllGOk_calc") #! Field("BSOC:LI01:1:AllGOk_calc.INPA",16777215,0,"BSOC:LI01:1:AllGOk_calc.INPA") #! Link("BSOC:LI01:1:AllGOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb109.VAL") #! Field("BSOC:LI01:1:AllGOk_calc.INPB",16777215,1,"BSOC:LI01:1:AllGOk_calc.INPB") #! Field("BSOC:LI01:1:AllGOk_calc.OUT",16777215,1,"BSOC:LI01:1:AllGOk_calc.OUT") #! Link("BSOC:LI01:1:AllGOk_calc.OUT","BSOC:LI01:1:AllGOk.VAL") #! Record("BSOC:LI01:1:AllGOk",500,20,0,0,"BSOC:LI01:1:AllGOk") #! Field("BSOC:LI01:1:AllGOk.VAL",16777215,1,"BSOC:LI01:1:AllGOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi108") { field(DESC, "Port LI01_BSOIC_Rd bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 108, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:AllNOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi108Valid") { field(INPA, "PLC:LI01:PP02:Bi108.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:AllNOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:AllNOk_calc") { field(INPA, "PLC:LI01:PP02:Bi108 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi108Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:AllNOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:AllNOk") { field(DESC, "BSOIC-All_Neutron_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb108",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb108") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb108.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb108.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb108.FLNK","BSOC:LI01:1:AllNOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb108.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb108.VAL") #! Record("BSOC:LI01:1:AllNOk_calc",260,18,0,1,"BSOC:LI01:1:AllNOk_calc") #! Field("BSOC:LI01:1:AllNOk_calc.INPA",16777215,0,"BSOC:LI01:1:AllNOk_calc.INPA") #! Link("BSOC:LI01:1:AllNOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb108.VAL") #! Field("BSOC:LI01:1:AllNOk_calc.INPB",16777215,1,"BSOC:LI01:1:AllNOk_calc.INPB") #! Field("BSOC:LI01:1:AllNOk_calc.OUT",16777215,1,"BSOC:LI01:1:AllNOk_calc.OUT") #! Link("BSOC:LI01:1:AllNOk_calc.OUT","BSOC:LI01:1:AllNOk.VAL") #! Record("BSOC:LI01:1:AllNOk",500,20,0,0,"BSOC:LI01:1:AllNOk") #! Field("BSOC:LI01:1:AllNOk.VAL",16777215,1,"BSOC:LI01:1:AllNOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi107") { field(DESC, "Port LI01_BSOIC_Rd bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:1:AllOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi107Valid") { field(INPA, "PLC:LI01:PP02:Bi107.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:AllOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:AllOk_calc") { field(INPA, "PLC:LI01:PP02:Bi107 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi107Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:AllOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:AllOk") { field(DESC, "BSOIC-All_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb107",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb107") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb107.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb107.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb107.FLNK","BSOC:LI01:1:AllOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb107.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb107.VAL") #! Record("BSOC:LI01:1:AllOk_calc",260,18,0,1,"BSOC:LI01:1:AllOk_calc") #! Field("BSOC:LI01:1:AllOk_calc.INPA",16777215,0,"BSOC:LI01:1:AllOk_calc.INPA") #! Link("BSOC:LI01:1:AllOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb107.VAL") #! Field("BSOC:LI01:1:AllOk_calc.INPB",16777215,1,"BSOC:LI01:1:AllOk_calc.INPB") #! Field("BSOC:LI01:1:AllOk_calc.OUT",16777215,1,"BSOC:LI01:1:AllOk_calc.OUT") #! Link("BSOC:LI01:1:AllOk_calc.OUT","BSOC:LI01:1:AllOk.VAL") #! Record("BSOC:LI01:1:AllOk",500,20,0,0,"BSOC:LI01:1:AllOk") #! Field("BSOC:LI01:1:AllOk.VAL",16777215,1,"BSOC:LI01:1:AllOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi106") { field(DESC, "Port LI01_BSOIC_Rd bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 106, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI02:05:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi106Valid") { field(INPA, "PLC:LI01:PP02:Bi106.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:EqpWarn_calc") { field(INPA, "PLC:LI01:PP02:Bi106 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi106Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb106",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb106") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb106.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb106.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb106.FLNK","BSOC:LI02:05:EqpWarn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb106.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb106.VAL") #! Record("BSOC:LI02:05:EqpWarn_calc",260,18,0,1,"BSOC:LI02:05:EqpWarn_calc") #! Field("BSOC:LI02:05:EqpWarn_calc.INPA",16777215,0,"BSOC:LI02:05:EqpWarn_calc.INPA") #! Link("BSOC:LI02:05:EqpWarn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb106.VAL") #! Field("BSOC:LI02:05:EqpWarn_calc.INPB",16777215,1,"BSOC:LI02:05:EqpWarn_calc.INPB") #! Field("BSOC:LI02:05:EqpWarn_calc.OUT",16777215,1,"BSOC:LI02:05:EqpWarn_calc.OUT") #! Link("BSOC:LI02:05:EqpWarn_calc.OUT","BSOC:LI02:05:EqpWarn.VAL") #! Record("BSOC:LI02:05:EqpWarn",500,20,0,0,"BSOC:LI02:05:EqpWarn") #! Field("BSOC:LI02:05:EqpWarn.VAL",16777215,1,"BSOC:LI02:05:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi105") { field(DESC, "Port LI01_BSOIC_Rd bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 105, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI01:G2:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi105Valid") { field(INPA, "PLC:LI01:PP02:Bi105.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:EqpWarn_calc") { field(INPA, "PLC:LI01:PP02:Bi105 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi105Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb105",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb105") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb105.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb105.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb105.FLNK","BSOC:LI01:G2:EqpWarn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb105.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb105.VAL") #! Record("BSOC:LI01:G2:EqpWarn_calc",260,18,0,1,"BSOC:LI01:G2:EqpWarn_calc") #! Field("BSOC:LI01:G2:EqpWarn_calc.INPA",16777215,0,"BSOC:LI01:G2:EqpWarn_calc.INPA") #! Link("BSOC:LI01:G2:EqpWarn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb105.VAL") #! Field("BSOC:LI01:G2:EqpWarn_calc.INPB",16777215,1,"BSOC:LI01:G2:EqpWarn_calc.INPB") #! Field("BSOC:LI01:G2:EqpWarn_calc.OUT",16777215,1,"BSOC:LI01:G2:EqpWarn_calc.OUT") #! Link("BSOC:LI01:G2:EqpWarn_calc.OUT","BSOC:LI01:G2:EqpWarn.VAL") #! Record("BSOC:LI01:G2:EqpWarn",500,20,0,0,"BSOC:LI01:G2:EqpWarn") #! Field("BSOC:LI01:G2:EqpWarn.VAL",16777215,1,"BSOC:LI01:G2:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi104") { field(DESC, "Port LI01_BSOIC_Rd bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 104, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI01:G3:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi104Valid") { field(INPA, "PLC:LI01:PP02:Bi104.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:EqpWarn_calc") { field(INPA, "PLC:LI01:PP02:Bi104 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi104Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb104",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb104") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb104.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb104.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb104.FLNK","BSOC:LI01:G3:EqpWarn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb104.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb104.VAL") #! Record("BSOC:LI01:G3:EqpWarn_calc",260,18,0,1,"BSOC:LI01:G3:EqpWarn_calc") #! Field("BSOC:LI01:G3:EqpWarn_calc.INPA",16777215,0,"BSOC:LI01:G3:EqpWarn_calc.INPA") #! Link("BSOC:LI01:G3:EqpWarn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb104.VAL") #! Field("BSOC:LI01:G3:EqpWarn_calc.INPB",16777215,1,"BSOC:LI01:G3:EqpWarn_calc.INPB") #! Field("BSOC:LI01:G3:EqpWarn_calc.OUT",16777215,1,"BSOC:LI01:G3:EqpWarn_calc.OUT") #! Link("BSOC:LI01:G3:EqpWarn_calc.OUT","BSOC:LI01:G3:EqpWarn.VAL") #! Record("BSOC:LI01:G3:EqpWarn",500,20,0,0,"BSOC:LI01:G3:EqpWarn") #! Field("BSOC:LI01:G3:EqpWarn.VAL",16777215,1,"BSOC:LI01:G3:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi119") { field(DESC, "Port LI01_BSOIC_Rd bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 119, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI01:G4:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi119Valid") { field(INPA, "PLC:LI01:PP02:Bi119.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:EqpWarn_calc") { field(INPA, "PLC:LI01:PP02:Bi119 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi119Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb119",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb119") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb119.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb119.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb119.FLNK","BSOC:LI01:G4:EqpWarn_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb119.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb119.VAL") #! Record("BSOC:LI01:G4:EqpWarn_calc",260,18,0,1,"BSOC:LI01:G4:EqpWarn_calc") #! Field("BSOC:LI01:G4:EqpWarn_calc.INPA",16777215,0,"BSOC:LI01:G4:EqpWarn_calc.INPA") #! Link("BSOC:LI01:G4:EqpWarn_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb119.VAL") #! Field("BSOC:LI01:G4:EqpWarn_calc.INPB",16777215,1,"BSOC:LI01:G4:EqpWarn_calc.INPB") #! Field("BSOC:LI01:G4:EqpWarn_calc.OUT",16777215,1,"BSOC:LI01:G4:EqpWarn_calc.OUT") #! Link("BSOC:LI01:G4:EqpWarn_calc.OUT","BSOC:LI01:G4:EqpWarn.VAL") #! Record("BSOC:LI01:G4:EqpWarn",500,20,0,0,"BSOC:LI01:G4:EqpWarn") #! Field("BSOC:LI01:G4:EqpWarn.VAL",16777215,1,"BSOC:LI01:G4:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi117") { field(DESC, "Port LI01_BSOIC_Rd bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 117, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI01:1:PLCHB_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi117Valid") { field(INPA, "PLC:LI01:PP02:Bi117.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:1:PLCHB_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:1:PLCHB_calc") { field(INPA, "PLC:LI01:PP02:Bi117 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi117Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:1:PLCHB PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:1:PLCHB") { field(DESC, "BSOIC-PLC_Heartbeat") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb117",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb117") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb117.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb117.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb117.FLNK","BSOC:LI01:1:PLCHB_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb117.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb117.VAL") #! Record("BSOC:LI01:1:PLCHB_calc",260,18,0,1,"BSOC:LI01:1:PLCHB_calc") #! Field("BSOC:LI01:1:PLCHB_calc.INPA",16777215,0,"BSOC:LI01:1:PLCHB_calc.INPA") #! Link("BSOC:LI01:1:PLCHB_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb117.VAL") #! Field("BSOC:LI01:1:PLCHB_calc.INPB",16777215,1,"BSOC:LI01:1:PLCHB_calc.INPB") #! Field("BSOC:LI01:1:PLCHB_calc.OUT",16777215,1,"BSOC:LI01:1:PLCHB_calc.OUT") #! Link("BSOC:LI01:1:PLCHB_calc.OUT","BSOC:LI01:1:PLCHB.VAL") #! Record("BSOC:LI01:1:PLCHB",500,20,0,0,"BSOC:LI01:1:PLCHB") #! Field("BSOC:LI01:1:PLCHB.VAL",16777215,1,"BSOC:LI01:1:PLCHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi116") { field(DESC, "Port LI01_BSOIC_Rd bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 116, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI02:05:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi116Valid") { field(INPA, "PLC:LI01:PP02:Bi116.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI02:05:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI02:05:ChOk_calc") { field(INPA, "PLC:LI01:PP02:Bi116 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi116Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI02:05:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI02:05:ChOk") { field(DESC, "BSOIC-CH1_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb116",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb116") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb116.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb116.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb116.FLNK","BSOC:LI02:05:ChOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb116.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb116.VAL") #! Record("BSOC:LI02:05:ChOk_calc",260,18,0,1,"BSOC:LI02:05:ChOk_calc") #! Field("BSOC:LI02:05:ChOk_calc.INPA",16777215,0,"BSOC:LI02:05:ChOk_calc.INPA") #! Link("BSOC:LI02:05:ChOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb116.VAL") #! Field("BSOC:LI02:05:ChOk_calc.INPB",16777215,1,"BSOC:LI02:05:ChOk_calc.INPB") #! Field("BSOC:LI02:05:ChOk_calc.OUT",16777215,1,"BSOC:LI02:05:ChOk_calc.OUT") #! Link("BSOC:LI02:05:ChOk_calc.OUT","BSOC:LI02:05:ChOk.VAL") #! Record("BSOC:LI02:05:ChOk",500,20,0,0,"BSOC:LI02:05:ChOk") #! Field("BSOC:LI02:05:ChOk.VAL",16777215,1,"BSOC:LI02:05:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi115") { field(DESC, "Port LI01_BSOIC_Rd bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 115, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G2:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi115Valid") { field(INPA, "PLC:LI01:PP02:Bi115.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G2:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G2:ChOk_calc") { field(INPA, "PLC:LI01:PP02:Bi115 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi115Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G2:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G2:ChOk") { field(DESC, "BSOIC-CH2_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb115",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb115") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb115.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb115.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb115.FLNK","BSOC:LI01:G2:ChOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb115.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb115.VAL") #! Record("BSOC:LI01:G2:ChOk_calc",260,18,0,1,"BSOC:LI01:G2:ChOk_calc") #! Field("BSOC:LI01:G2:ChOk_calc.INPA",16777215,0,"BSOC:LI01:G2:ChOk_calc.INPA") #! Link("BSOC:LI01:G2:ChOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb115.VAL") #! Field("BSOC:LI01:G2:ChOk_calc.INPB",16777215,1,"BSOC:LI01:G2:ChOk_calc.INPB") #! Field("BSOC:LI01:G2:ChOk_calc.OUT",16777215,1,"BSOC:LI01:G2:ChOk_calc.OUT") #! Link("BSOC:LI01:G2:ChOk_calc.OUT","BSOC:LI01:G2:ChOk.VAL") #! Record("BSOC:LI01:G2:ChOk",500,20,0,0,"BSOC:LI01:G2:ChOk") #! Field("BSOC:LI01:G2:ChOk.VAL",16777215,1,"BSOC:LI01:G2:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi114") { field(DESC, "Port LI01_BSOIC_Rd bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 114, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G3:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi114Valid") { field(INPA, "PLC:LI01:PP02:Bi114.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G3:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G3:ChOk_calc") { field(INPA, "PLC:LI01:PP02:Bi114 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi114Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G3:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G3:ChOk") { field(DESC, "BSOIC-CH3_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb114",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb114") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb114.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb114.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb114.FLNK","BSOC:LI01:G3:ChOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb114.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb114.VAL") #! Record("BSOC:LI01:G3:ChOk_calc",260,18,0,1,"BSOC:LI01:G3:ChOk_calc") #! Field("BSOC:LI01:G3:ChOk_calc.INPA",16777215,0,"BSOC:LI01:G3:ChOk_calc.INPA") #! Link("BSOC:LI01:G3:ChOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb114.VAL") #! Field("BSOC:LI01:G3:ChOk_calc.INPB",16777215,1,"BSOC:LI01:G3:ChOk_calc.INPB") #! Field("BSOC:LI01:G3:ChOk_calc.OUT",16777215,1,"BSOC:LI01:G3:ChOk_calc.OUT") #! Link("BSOC:LI01:G3:ChOk_calc.OUT","BSOC:LI01:G3:ChOk.VAL") #! Record("BSOC:LI01:G3:ChOk",500,20,0,0,"BSOC:LI01:G3:ChOk") #! Field("BSOC:LI01:G3:ChOk.VAL",16777215,1,"BSOC:LI01:G3:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi113") { field(DESC, "Port LI01_BSOIC_Rd bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 113, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:G4:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi113Valid") { field(INPA, "PLC:LI01:PP02:Bi113.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:G4:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:G4:ChOk_calc") { field(INPA, "PLC:LI01:PP02:Bi113 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi113Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:G4:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:G4:ChOk") { field(DESC, "BSOIC-CH4_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb113",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb113") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb113.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb113.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb113.FLNK","BSOC:LI01:G4:ChOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb113.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb113.VAL") #! Record("BSOC:LI01:G4:ChOk_calc",260,18,0,1,"BSOC:LI01:G4:ChOk_calc") #! Field("BSOC:LI01:G4:ChOk_calc.INPA",16777215,0,"BSOC:LI01:G4:ChOk_calc.INPA") #! Link("BSOC:LI01:G4:ChOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb113.VAL") #! Field("BSOC:LI01:G4:ChOk_calc.INPB",16777215,1,"BSOC:LI01:G4:ChOk_calc.INPB") #! Field("BSOC:LI01:G4:ChOk_calc.OUT",16777215,1,"BSOC:LI01:G4:ChOk_calc.OUT") #! Link("BSOC:LI01:G4:ChOk_calc.OUT","BSOC:LI01:G4:ChOk.VAL") #! Record("BSOC:LI01:G4:ChOk",500,20,0,0,"BSOC:LI01:G4:ChOk") #! Field("BSOC:LI01:G4:ChOk.VAL",16777215,1,"BSOC:LI01:G4:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi112") { field(DESC, "Port LI01_BSOIC_Rd bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 112, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:N1:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi112Valid") { field(INPA, "PLC:LI01:PP02:Bi112.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N1:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N1:ChOk_calc") { field(INPA, "PLC:LI01:PP02:Bi112 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi112Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N1:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N1:ChOk") { field(DESC, "BSOIC-CH5_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb112",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb112") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb112.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb112.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb112.FLNK","BSOC:LI01:N1:ChOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb112.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb112.VAL") #! Record("BSOC:LI01:N1:ChOk_calc",260,18,0,1,"BSOC:LI01:N1:ChOk_calc") #! Field("BSOC:LI01:N1:ChOk_calc.INPA",16777215,0,"BSOC:LI01:N1:ChOk_calc.INPA") #! Link("BSOC:LI01:N1:ChOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb112.VAL") #! Field("BSOC:LI01:N1:ChOk_calc.INPB",16777215,1,"BSOC:LI01:N1:ChOk_calc.INPB") #! Field("BSOC:LI01:N1:ChOk_calc.OUT",16777215,1,"BSOC:LI01:N1:ChOk_calc.OUT") #! Link("BSOC:LI01:N1:ChOk_calc.OUT","BSOC:LI01:N1:ChOk.VAL") #! Record("BSOC:LI01:N1:ChOk",500,20,0,0,"BSOC:LI01:N1:ChOk") #! Field("BSOC:LI01:N1:ChOk.VAL",16777215,1,"BSOC:LI01:N1:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI01:PP02:Bi127") { field(DESC, "Port LI01_BSOIC_Rd bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 127, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI01:N2:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:Bi127Valid") { field(INPA, "PLC:LI01:PP02:Bi127.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI01:N2:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI01:N2:ChOk_calc") { field(INPA, "PLC:LI01:PP02:Bi127 NPP NMS") field(INPB, "PLC:LI01:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI01:PP02:Bi127Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI01:N2:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI01:N2:ChOk") { field(DESC, "BSOIC-CH6_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI01:PP02:LI01_BSOIC_Rdb127",20,19,0,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb127") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb127.FLNK",16777215,1,"PLC:LI01:PP02:LI01_BSOIC_Rdb127.FLNK") #! Link("PLC:LI01:PP02:LI01_BSOIC_Rdb127.FLNK","BSOC:LI01:N2:ChOk_calc") #! Field("PLC:LI01:PP02:LI01_BSOIC_Rdb127.VAL",16777215,0,"PLC:LI01:PP02:LI01_BSOIC_Rdb127.VAL") #! Record("BSOC:LI01:N2:ChOk_calc",260,18,0,1,"BSOC:LI01:N2:ChOk_calc") #! Field("BSOC:LI01:N2:ChOk_calc.INPA",16777215,0,"BSOC:LI01:N2:ChOk_calc.INPA") #! Link("BSOC:LI01:N2:ChOk_calc.INPA","PLC:LI01:PP02:LI01_BSOIC_Rdb127.VAL") #! Field("BSOC:LI01:N2:ChOk_calc.INPB",16777215,1,"BSOC:LI01:N2:ChOk_calc.INPB") #! Field("BSOC:LI01:N2:ChOk_calc.OUT",16777215,1,"BSOC:LI01:N2:ChOk_calc.OUT") #! Link("BSOC:LI01:N2:ChOk_calc.OUT","BSOC:LI01:N2:ChOk.VAL") #! Record("BSOC:LI01:N2:ChOk",500,20,0,0,"BSOC:LI01:N2:ChOk") #! Field("BSOC:LI01:N2:ChOk.VAL",16777215,1,"BSOC:LI01:N2:ChOk.VAL") record(bo, "BSOC:LI02:05:SReset") { field(DESC, "BSOIC-Soft_Reset_G1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:G2:SReset") { field(DESC, "BSOIC-Soft_Reset_G2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:G3:SReset") { field(DESC, "BSOIC-Soft_Reset_G3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 5, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:G4:SReset") { field(DESC, "BSOIC-Soft_Reset_G4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 4, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:N1:SReset") { field(DESC, "BSOIC-Soft_Reset_N1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:N2:SReset") { field(DESC, "BSOIC-Soft_Reset_N2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 2, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:1:SResetAll") { field(DESC, "BSOIC-Soft_Reset_All") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 1, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI01:1:SPauseHB") { field(DESC, "BSOIC-Soft_Pause_Hb") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Pause") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:LI01:PP02:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:LI01:PP02:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:LI01:PP02:TABLE_CYCLER") { field( OUT, "PLC:LI01:PP02:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:LI01:PP02:SEG_CYCLER") { field( OUT, "PLC:LI01:PP02:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:LI01:PP02:TABLE_9_SEG_1") { field( INPA, "PLC:LI01:PP02:REQ_TABLE CP") field( INPB, "PLC:LI01:PP02:REQ_SEG CP") field( INPC, "PLC:LI01:PP02:REQ_TABLE_IN CP") field( INPD, "PLC:LI01:PP02:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:LI01:PP02:TABLE_1_SEG_1") { field( INPA, "PLC:LI01:PP02:REQ_TABLE CP") field( INPB, "PLC:LI01:PP02:REQ_SEG CP") field( INPC, "PLC:LI01:PP02:REQ_TABLE_IN CP") field( INPD, "PLC:LI01:PP02:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI01:PP02:REQ_TABLE_OUT") { field(OUTA, "PLC:LI01:PP02:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:LI01:PP02:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:LI01:PP02:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:LI01:PP02:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:LI01:PP02:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:LI01:PP02:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:LI01:PP02:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:LI01:PP02:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:LI01:PP02:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT0 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT1 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT2 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT3 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT4 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT5 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT6 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:LI01:PP02:REQ_TABLE_OUT") field(INPB, "PLC:LI01:PP02:TABLE_BIT7 MS") field(INPC, "PLC:LI01:PP02:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI01:PP02:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:LI01:PP02:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:LI01:PP02:TABLE_BIT0 CP MS") field(INPB, "PLC:LI01:PP02:TABLE_BIT1 CP MS") field(INPC, "PLC:LI01:PP02:TABLE_BIT2 CP MS") field(INPD, "PLC:LI01:PP02:TABLE_BIT3 CP MS") field(INPE, "PLC:LI01:PP02:TABLE_BIT4 CP MS") field(INPF, "PLC:LI01:PP02:TABLE_BIT5 CP MS") field(INPG, "PLC:LI01:PP02:TABLE_BIT6 CP MS") field(INPH, "PLC:LI01:PP02:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI01:PP02:REQ_TABLE PP MS") #field(SDIS, "PLC:LI01:PP02:REQ_TABLE_OUT.PACT") } record(longout, "PLC:LI01:PP02:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:LI01:PP02:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI01:PP02:REQ_SEG_OUT") { field(OUTA, "PLC:LI01:PP02:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:LI01:PP02:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:LI01:PP02:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:LI01:PP02:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:LI01:PP02:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:LI01:PP02:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:LI01:PP02:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:LI01:PP02:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:LI01:PP02:REQ_SEG_IN.PACT") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT0 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT1 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT1 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT2 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT2 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT3 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT3 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT4 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT4 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT5 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT5 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT6 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT6 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:LI01:PP02:REQ_SEG_OUT") field(INPB, "PLC:LI01:PP02:SEG_BIT7 MS") field(INPC, "PLC:LI01:PP02:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI01:PP02:REQ_SEG_BIT7 PP") } record(calcout, "PLC:LI01:PP02:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:LI01:PP02:SEG_BIT0 CP MS") field(INPB, "PLC:LI01:PP02:SEG_BIT1 CP MS") field(INPC, "PLC:LI01:PP02:SEG_BIT2 CP MS") field(INPD, "PLC:LI01:PP02:SEG_BIT3 CP MS") field(INPE, "PLC:LI01:PP02:SEG_BIT4 CP MS") field(INPF, "PLC:LI01:PP02:SEG_BIT5 CP MS") field(INPG, "PLC:LI01:PP02:SEG_BIT6 CP MS") field(INPH, "PLC:LI01:PP02:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI01:PP02:REQ_SEG PP MS") field(SDIS, "PLC:LI01:PP02:REQ_SEG_OUT.PACT") } record(bi, "PLC:LI01:PP02:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:PWLED") { field(DESC, "PLC-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:RUNLED") { field(DESC, "PLC-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:DIAGLED") { field(DESC, "PLC-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:FAULTLED") { field(DESC, "PLC-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:IFAULTLED") { field(DESC, "PLC-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:OFAULTLED") { field(DESC, "PLC-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI01:PP02:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Rd, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI01:PP02:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI01_BSOIC_Wrt, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:LI01:PP02:w0") { field(DESC, "Checksum word 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:w1") { field(DESC, "Checksum word 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 2, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:LI01:PP02:CHECKSUM_SDIS") { field(INPA, "PLC:LI01:PP02:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:LI01:PP02:w3") { field(DESC, "Checksum word 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 3, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:CHECKSUM_SAFE_calc") { field(INPA, "PLC:LI01:PP02:w3 PP MS") field(INPB, "PLC:LI01:PP02:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI01:PP02:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:LI01:PP02:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI01:PP02:w4") { field(DESC, "Checksum word 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 4, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:PROJ_CHECKSUM_calc") { field(INPA, "PLC:LI01:PP02:w4 NPP MS") field(INPB, "PLC:LI01:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI01:PP02:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI01:PP02:w5") { field(DESC, "Checksum word 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 5, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:DAY_MONTH_calc") { field(INPA, "PLC:LI01:PP02:w5 NPP MS") field(INPB, "PLC:LI01:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI01:PP02:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:LI01:PP02:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:LI01:PP02:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:LI01:PP02:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:LI01:PP02:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI01:PP02:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 6, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:PROJ_YEAR_calc") { field(INPA, "PLC:LI01:PP02:w6 NPP MS") field(INPB, "PLC:LI01:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI01:PP02:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI01:PP02:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 7, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:OP_HRS_MSB_calc") { field(INPA, "PLC:LI01:PP02:w7 NPP MS") field(INPB, "PLC:LI01:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI01:PP02:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI01_BSOIC_Wd, 8, 0xFFFF, 1)") field(FLNK, "PLC:LI01:PP02:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI01:PP02:OP_HRS_LSB_calc") { field(INPA, "PLC:LI01:PP02:w8 NPP MS") field(INPB, "PLC:LI01:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI01:PP02:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI01:PP02:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:LI01:PP02:OP_HOURS") { field(INPA, "PLC:LI01:PP02:OP_HRS_MSB CP MS") field(INPB, "PLC:LI01:PP02:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:LI01:PP02:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:LI01:PP02:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:LI01:PP02:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI01_BSOIC_Rd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI01:PP02:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI01:PP02:RDHist.PROC") } record(waveform,"PLC:LI01:PP02:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI01_BSOIC_Rd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI01:PP02:RDHistTimeAxis.PROC") } record(waveform,"PLC:LI01:PP02:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI01_BSOIC_Rd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI01:PP02:RDReadOK.PROC") } record(longout,"PLC:LI01:PP02:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI01_BSOIC_Rd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI01:PP02:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Rd 0)READ_OK") field(FLNK,"PLC:LI01:PP02:RDWriteOK.PROC") } record(longin,"PLC:LI01:PP02:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Rd 0)WRITE_OK") field(FLNK,"PLC:LI01:PP02:RDIOErrors.PROC") } record(longin,"PLC:LI01:PP02:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Rd 0)IO_ERRORS") field(FLNK,"PLC:LI01:PP02:RDLastIOTime.PROC") } record(longin,"PLC:LI01:PP02:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Rd 0)LAST_IO_TIME") field(FLNK,"PLC:LI01:PP02:RDMaxIOTime.PROC") } record(longin,"PLC:LI01:PP02:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Rd 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI01:PP02:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI01_BSOIC_Wrt 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI01:PP02:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI01:PP02:WRTHist.PROC") } record(waveform,"PLC:LI01:PP02:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI01_BSOIC_Wrt 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI01:PP02:WRTHistTimeAxis.PROC") } record(waveform,"PLC:LI01:PP02:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI01_BSOIC_Wrt 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI01:PP02:WRTReadOK.PROC") } record(longout,"PLC:LI01:PP02:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI01_BSOIC_Wrt 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI01:PP02:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wrt 0)READ_OK") field(FLNK,"PLC:LI01:PP02:WRTWriteOK.PROC") } record(longin,"PLC:LI01:PP02:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wrt 0)WRITE_OK") field(FLNK,"PLC:LI01:PP02:WRTIOErrors.PROC") } record(longin,"PLC:LI01:PP02:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wrt 0)IO_ERRORS") field(FLNK,"PLC:LI01:PP02:WRTLastIOTime.PROC") } record(longin,"PLC:LI01:PP02:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wrt 0)LAST_IO_TIME") field(FLNK,"PLC:LI01:PP02:WRTMaxIOTime.PROC") } record(longin,"PLC:LI01:PP02:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wrt 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI01:PP02:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI01_BSOIC_Wd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI01:PP02:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI01:PP02:WDHist.PROC") } record(waveform,"PLC:LI01:PP02:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI01_BSOIC_Wd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI01:PP02:WDHistTimeAxis.PROC") } record(waveform,"PLC:LI01:PP02:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI01_BSOIC_Wd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI01:PP02:WDReadOK.PROC") } record(longout,"PLC:LI01:PP02:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI01_BSOIC_Wd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI01:PP02:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wd 0)READ_OK") field(FLNK,"PLC:LI01:PP02:WDWriteOK.PROC") } record(longin,"PLC:LI01:PP02:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wd 0)WRITE_OK") field(FLNK,"PLC:LI01:PP02:WDIOErrors.PROC") } record(longin,"PLC:LI01:PP02:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wd 0)IO_ERRORS") field(FLNK,"PLC:LI01:PP02:WDLastIOTime.PROC") } record(longin,"PLC:LI01:PP02:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wd 0)LAST_IO_TIME") field(FLNK,"PLC:LI01:PP02:WDMaxIOTime.PROC") } record(longin,"PLC:LI01:PP02:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI01_BSOIC_Wd 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi7") { field(DESC, "Port LI03_BSOIC_Rd bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BSOC:LI03:1:HwEn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi7Valid") { field(INPA, "PLC:LI03:PP01:Bi7.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:HwEn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:HwEn_calc") { field(INPA, "PLC:LI03:PP01:Bi7 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi7Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:HwEn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:HwEn") { field(DESC, "BSOIC-HW_Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb7",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb7") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb7.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb7.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb7.FLNK","BSOC:LI03:1:HwEn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb7.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb7.VAL") #! Record("BSOC:LI03:1:HwEn_calc",260,18,0,1,"BSOC:LI03:1:HwEn_calc") #! Field("BSOC:LI03:1:HwEn_calc.INPA",16777215,0,"BSOC:LI03:1:HwEn_calc.INPA") #! Link("BSOC:LI03:1:HwEn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb7.VAL") #! Field("BSOC:LI03:1:HwEn_calc.INPB",16777215,1,"BSOC:LI03:1:HwEn_calc.INPB") #! Field("BSOC:LI03:1:HwEn_calc.OUT",16777215,1,"BSOC:LI03:1:HwEn_calc.OUT") #! Link("BSOC:LI03:1:HwEn_calc.OUT","BSOC:LI03:1:HwEn.VAL") #! Record("BSOC:LI03:1:HwEn",500,20,0,0,"BSOC:LI03:1:HwEn") #! Field("BSOC:LI03:1:HwEn.VAL",16777215,1,"BSOC:LI03:1:HwEn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi6") { field(DESC, "Port LI03_BSOIC_Rd bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI03:1:HwResetAll_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi6Valid") { field(INPA, "PLC:LI03:PP01:Bi6.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:HwResetAll_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:HwResetAll_calc") { field(INPA, "PLC:LI03:PP01:Bi6 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi6Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:HwResetAll PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:HwResetAll") { field(DESC, "BSOIC-HW_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb6",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb6") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb6.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb6.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb6.FLNK","BSOC:LI03:1:HwResetAll_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb6.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb6.VAL") #! Record("BSOC:LI03:1:HwResetAll_calc",260,18,0,1,"BSOC:LI03:1:HwResetAll_calc") #! Field("BSOC:LI03:1:HwResetAll_calc.INPA",16777215,0,"BSOC:LI03:1:HwResetAll_calc.INPA") #! Link("BSOC:LI03:1:HwResetAll_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb6.VAL") #! Field("BSOC:LI03:1:HwResetAll_calc.INPB",16777215,1,"BSOC:LI03:1:HwResetAll_calc.INPB") #! Field("BSOC:LI03:1:HwResetAll_calc.OUT",16777215,1,"BSOC:LI03:1:HwResetAll_calc.OUT") #! Link("BSOC:LI03:1:HwResetAll_calc.OUT","BSOC:LI03:1:HwResetAll.VAL") #! Record("BSOC:LI03:1:HwResetAll",500,20,0,0,"BSOC:LI03:1:HwResetAll") #! Field("BSOC:LI03:1:HwResetAll.VAL",16777215,1,"BSOC:LI03:1:HwResetAll.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi5") { field(DESC, "Port LI03_BSOIC_Rd bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:06:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi5Valid") { field(INPA, "PLC:LI03:PP01:Bi5.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:Eqp_calc") { field(INPA, "PLC:LI03:PP01:Bi5 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi5Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:Eqp") { field(DESC, "BSOIC-RT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb5",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb5") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb5.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb5.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb5.FLNK","BSOC:LI04:06:Eqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb5.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb5.VAL") #! Record("BSOC:LI04:06:Eqp_calc",260,18,0,1,"BSOC:LI04:06:Eqp_calc") #! Field("BSOC:LI04:06:Eqp_calc.INPA",16777215,0,"BSOC:LI04:06:Eqp_calc.INPA") #! Link("BSOC:LI04:06:Eqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb5.VAL") #! Field("BSOC:LI04:06:Eqp_calc.INPB",16777215,1,"BSOC:LI04:06:Eqp_calc.INPB") #! Field("BSOC:LI04:06:Eqp_calc.OUT",16777215,1,"BSOC:LI04:06:Eqp_calc.OUT") #! Link("BSOC:LI04:06:Eqp_calc.OUT","BSOC:LI04:06:Eqp.VAL") #! Record("BSOC:LI04:06:Eqp",500,20,0,0,"BSOC:LI04:06:Eqp") #! Field("BSOC:LI04:06:Eqp.VAL",16777215,1,"BSOC:LI04:06:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi4") { field(DESC, "Port LI03_BSOIC_Rd bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 4, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:06:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi4Valid") { field(INPA, "PLC:LI03:PP01:Bi4.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:Rad_calc") { field(INPA, "PLC:LI03:PP01:Bi4 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi4Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:Rad") { field(DESC, "BSOIC-RT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb4",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb4") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb4.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb4.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb4.FLNK","BSOC:LI04:06:Rad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb4.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb4.VAL") #! Record("BSOC:LI04:06:Rad_calc",260,18,0,1,"BSOC:LI04:06:Rad_calc") #! Field("BSOC:LI04:06:Rad_calc.INPA",16777215,0,"BSOC:LI04:06:Rad_calc.INPA") #! Link("BSOC:LI04:06:Rad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb4.VAL") #! Field("BSOC:LI04:06:Rad_calc.INPB",16777215,1,"BSOC:LI04:06:Rad_calc.INPB") #! Field("BSOC:LI04:06:Rad_calc.OUT",16777215,1,"BSOC:LI04:06:Rad_calc.OUT") #! Link("BSOC:LI04:06:Rad_calc.OUT","BSOC:LI04:06:Rad.VAL") #! Record("BSOC:LI04:06:Rad",500,20,0,0,"BSOC:LI04:06:Rad") #! Field("BSOC:LI04:06:Rad.VAL",16777215,1,"BSOC:LI04:06:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi3") { field(DESC, "Port LI03_BSOIC_Rd bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI04:06:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi3Valid") { field(INPA, "PLC:LI03:PP01:Bi3.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:HWBypass_calc") { field(INPA, "PLC:LI03:PP01:Bi3 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi3Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:HWBypass") { field(DESC, "BSOIC-RT_G1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb3",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb3") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb3.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb3.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb3.FLNK","BSOC:LI04:06:HWBypass_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb3.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb3.VAL") #! Record("BSOC:LI04:06:HWBypass_calc",260,18,0,1,"BSOC:LI04:06:HWBypass_calc") #! Field("BSOC:LI04:06:HWBypass_calc.INPA",16777215,0,"BSOC:LI04:06:HWBypass_calc.INPA") #! Link("BSOC:LI04:06:HWBypass_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb3.VAL") #! Field("BSOC:LI04:06:HWBypass_calc.INPB",16777215,1,"BSOC:LI04:06:HWBypass_calc.INPB") #! Field("BSOC:LI04:06:HWBypass_calc.OUT",16777215,1,"BSOC:LI04:06:HWBypass_calc.OUT") #! Link("BSOC:LI04:06:HWBypass_calc.OUT","BSOC:LI04:06:HWBypass.VAL") #! Record("BSOC:LI04:06:HWBypass",500,20,0,0,"BSOC:LI04:06:HWBypass") #! Field("BSOC:LI04:06:HWBypass.VAL",16777215,1,"BSOC:LI04:06:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi2") { field(DESC, "Port LI03_BSOIC_Rd bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:07:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi2Valid") { field(INPA, "PLC:LI03:PP01:Bi2.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:Eqp_calc") { field(INPA, "PLC:LI03:PP01:Bi2 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi2Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:Eqp") { field(DESC, "BSOIC-RT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb2",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb2") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb2.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb2.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb2.FLNK","BSOC:LI04:07:Eqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb2.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb2.VAL") #! Record("BSOC:LI04:07:Eqp_calc",260,18,0,1,"BSOC:LI04:07:Eqp_calc") #! Field("BSOC:LI04:07:Eqp_calc.INPA",16777215,0,"BSOC:LI04:07:Eqp_calc.INPA") #! Link("BSOC:LI04:07:Eqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb2.VAL") #! Field("BSOC:LI04:07:Eqp_calc.INPB",16777215,1,"BSOC:LI04:07:Eqp_calc.INPB") #! Field("BSOC:LI04:07:Eqp_calc.OUT",16777215,1,"BSOC:LI04:07:Eqp_calc.OUT") #! Link("BSOC:LI04:07:Eqp_calc.OUT","BSOC:LI04:07:Eqp.VAL") #! Record("BSOC:LI04:07:Eqp",500,20,0,0,"BSOC:LI04:07:Eqp") #! Field("BSOC:LI04:07:Eqp.VAL",16777215,1,"BSOC:LI04:07:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi1") { field(DESC, "Port LI03_BSOIC_Rd bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:07:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi1Valid") { field(INPA, "PLC:LI03:PP01:Bi1.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:Rad_calc") { field(INPA, "PLC:LI03:PP01:Bi1 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi1Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:Rad") { field(DESC, "BSOIC-RT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb1",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb1") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb1.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb1.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb1.FLNK","BSOC:LI04:07:Rad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb1.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb1.VAL") #! Record("BSOC:LI04:07:Rad_calc",260,18,0,1,"BSOC:LI04:07:Rad_calc") #! Field("BSOC:LI04:07:Rad_calc.INPA",16777215,0,"BSOC:LI04:07:Rad_calc.INPA") #! Link("BSOC:LI04:07:Rad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb1.VAL") #! Field("BSOC:LI04:07:Rad_calc.INPB",16777215,1,"BSOC:LI04:07:Rad_calc.INPB") #! Field("BSOC:LI04:07:Rad_calc.OUT",16777215,1,"BSOC:LI04:07:Rad_calc.OUT") #! Link("BSOC:LI04:07:Rad_calc.OUT","BSOC:LI04:07:Rad.VAL") #! Record("BSOC:LI04:07:Rad",500,20,0,0,"BSOC:LI04:07:Rad") #! Field("BSOC:LI04:07:Rad.VAL",16777215,1,"BSOC:LI04:07:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi0") { field(DESC, "Port LI03_BSOIC_Rd bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI04:07:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi0Valid") { field(INPA, "PLC:LI03:PP01:Bi0.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:HWBypass_calc") { field(INPA, "PLC:LI03:PP01:Bi0 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi0Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:HWBypass") { field(DESC, "BSOIC-RT_G2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb0",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb0") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb0.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb0.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb0.FLNK","BSOC:LI04:07:HWBypass_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb0.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb0.VAL") #! Record("BSOC:LI04:07:HWBypass_calc",260,18,0,1,"BSOC:LI04:07:HWBypass_calc") #! Field("BSOC:LI04:07:HWBypass_calc.INPA",16777215,0,"BSOC:LI04:07:HWBypass_calc.INPA") #! Link("BSOC:LI04:07:HWBypass_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb0.VAL") #! Field("BSOC:LI04:07:HWBypass_calc.INPB",16777215,1,"BSOC:LI04:07:HWBypass_calc.INPB") #! Field("BSOC:LI04:07:HWBypass_calc.OUT",16777215,1,"BSOC:LI04:07:HWBypass_calc.OUT") #! Link("BSOC:LI04:07:HWBypass_calc.OUT","BSOC:LI04:07:HWBypass.VAL") #! Record("BSOC:LI04:07:HWBypass",500,20,0,0,"BSOC:LI04:07:HWBypass") #! Field("BSOC:LI04:07:HWBypass.VAL",16777215,1,"BSOC:LI04:07:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi15") { field(DESC, "Port LI03_BSOIC_Rd bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:08:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi15Valid") { field(INPA, "PLC:LI03:PP01:Bi15.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:Eqp_calc") { field(INPA, "PLC:LI03:PP01:Bi15 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi15Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:Eqp") { field(DESC, "BSOIC-RT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb15",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb15") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb15.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb15.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb15.FLNK","BSOC:LI05:08:Eqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb15.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb15.VAL") #! Record("BSOC:LI05:08:Eqp_calc",260,18,0,1,"BSOC:LI05:08:Eqp_calc") #! Field("BSOC:LI05:08:Eqp_calc.INPA",16777215,0,"BSOC:LI05:08:Eqp_calc.INPA") #! Link("BSOC:LI05:08:Eqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb15.VAL") #! Field("BSOC:LI05:08:Eqp_calc.INPB",16777215,1,"BSOC:LI05:08:Eqp_calc.INPB") #! Field("BSOC:LI05:08:Eqp_calc.OUT",16777215,1,"BSOC:LI05:08:Eqp_calc.OUT") #! Link("BSOC:LI05:08:Eqp_calc.OUT","BSOC:LI05:08:Eqp.VAL") #! Record("BSOC:LI05:08:Eqp",500,20,0,0,"BSOC:LI05:08:Eqp") #! Field("BSOC:LI05:08:Eqp.VAL",16777215,1,"BSOC:LI05:08:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi14") { field(DESC, "Port LI03_BSOIC_Rd bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:08:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi14Valid") { field(INPA, "PLC:LI03:PP01:Bi14.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:Rad_calc") { field(INPA, "PLC:LI03:PP01:Bi14 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi14Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:Rad") { field(DESC, "BSOIC-RT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb14",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb14") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb14.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb14.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb14.FLNK","BSOC:LI05:08:Rad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb14.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb14.VAL") #! Record("BSOC:LI05:08:Rad_calc",260,18,0,1,"BSOC:LI05:08:Rad_calc") #! Field("BSOC:LI05:08:Rad_calc.INPA",16777215,0,"BSOC:LI05:08:Rad_calc.INPA") #! Link("BSOC:LI05:08:Rad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb14.VAL") #! Field("BSOC:LI05:08:Rad_calc.INPB",16777215,1,"BSOC:LI05:08:Rad_calc.INPB") #! Field("BSOC:LI05:08:Rad_calc.OUT",16777215,1,"BSOC:LI05:08:Rad_calc.OUT") #! Link("BSOC:LI05:08:Rad_calc.OUT","BSOC:LI05:08:Rad.VAL") #! Record("BSOC:LI05:08:Rad",500,20,0,0,"BSOC:LI05:08:Rad") #! Field("BSOC:LI05:08:Rad.VAL",16777215,1,"BSOC:LI05:08:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi13") { field(DESC, "Port LI03_BSOIC_Rd bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 13, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI05:08:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi13Valid") { field(INPA, "PLC:LI03:PP01:Bi13.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:HWBypass_calc") { field(INPA, "PLC:LI03:PP01:Bi13 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi13Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:HWBypass") { field(DESC, "BSOIC-RT_G3_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb13",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb13") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb13.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb13.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb13.FLNK","BSOC:LI05:08:HWBypass_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb13.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb13.VAL") #! Record("BSOC:LI05:08:HWBypass_calc",260,18,0,1,"BSOC:LI05:08:HWBypass_calc") #! Field("BSOC:LI05:08:HWBypass_calc.INPA",16777215,0,"BSOC:LI05:08:HWBypass_calc.INPA") #! Link("BSOC:LI05:08:HWBypass_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb13.VAL") #! Field("BSOC:LI05:08:HWBypass_calc.INPB",16777215,1,"BSOC:LI05:08:HWBypass_calc.INPB") #! Field("BSOC:LI05:08:HWBypass_calc.OUT",16777215,1,"BSOC:LI05:08:HWBypass_calc.OUT") #! Link("BSOC:LI05:08:HWBypass_calc.OUT","BSOC:LI05:08:HWBypass.VAL") #! Record("BSOC:LI05:08:HWBypass",500,20,0,0,"BSOC:LI05:08:HWBypass") #! Field("BSOC:LI05:08:HWBypass.VAL",16777215,1,"BSOC:LI05:08:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi12") { field(DESC, "Port LI03_BSOIC_Rd bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:G4:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi12Valid") { field(INPA, "PLC:LI03:PP01:Bi12.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:Eqp_calc") { field(INPA, "PLC:LI03:PP01:Bi12 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi12Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:Eqp") { field(DESC, "BSOIC-RT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb12",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb12") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb12.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb12.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb12.FLNK","BSOC:LI03:G4:Eqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb12.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb12.VAL") #! Record("BSOC:LI03:G4:Eqp_calc",260,18,0,1,"BSOC:LI03:G4:Eqp_calc") #! Field("BSOC:LI03:G4:Eqp_calc.INPA",16777215,0,"BSOC:LI03:G4:Eqp_calc.INPA") #! Link("BSOC:LI03:G4:Eqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb12.VAL") #! Field("BSOC:LI03:G4:Eqp_calc.INPB",16777215,1,"BSOC:LI03:G4:Eqp_calc.INPB") #! Field("BSOC:LI03:G4:Eqp_calc.OUT",16777215,1,"BSOC:LI03:G4:Eqp_calc.OUT") #! Link("BSOC:LI03:G4:Eqp_calc.OUT","BSOC:LI03:G4:Eqp.VAL") #! Record("BSOC:LI03:G4:Eqp",500,20,0,0,"BSOC:LI03:G4:Eqp") #! Field("BSOC:LI03:G4:Eqp.VAL",16777215,1,"BSOC:LI03:G4:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi11") { field(DESC, "Port LI03_BSOIC_Rd bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:G4:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi11Valid") { field(INPA, "PLC:LI03:PP01:Bi11.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:Rad_calc") { field(INPA, "PLC:LI03:PP01:Bi11 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi11Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:Rad") { field(DESC, "BSOIC-RT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb11",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb11") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb11.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb11.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb11.FLNK","BSOC:LI03:G4:Rad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb11.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb11.VAL") #! Record("BSOC:LI03:G4:Rad_calc",260,18,0,1,"BSOC:LI03:G4:Rad_calc") #! Field("BSOC:LI03:G4:Rad_calc.INPA",16777215,0,"BSOC:LI03:G4:Rad_calc.INPA") #! Link("BSOC:LI03:G4:Rad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb11.VAL") #! Field("BSOC:LI03:G4:Rad_calc.INPB",16777215,1,"BSOC:LI03:G4:Rad_calc.INPB") #! Field("BSOC:LI03:G4:Rad_calc.OUT",16777215,1,"BSOC:LI03:G4:Rad_calc.OUT") #! Link("BSOC:LI03:G4:Rad_calc.OUT","BSOC:LI03:G4:Rad.VAL") #! Record("BSOC:LI03:G4:Rad",500,20,0,0,"BSOC:LI03:G4:Rad") #! Field("BSOC:LI03:G4:Rad.VAL",16777215,1,"BSOC:LI03:G4:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi10") { field(DESC, "Port LI03_BSOIC_Rd bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 10, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI03:G4:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi10Valid") { field(INPA, "PLC:LI03:PP01:Bi10.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:HWBypass_calc") { field(INPA, "PLC:LI03:PP01:Bi10 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi10Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:HWBypass") { field(DESC, "BSOIC-RT_G4_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb10",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb10") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb10.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb10.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb10.FLNK","BSOC:LI03:G4:HWBypass_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb10.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb10.VAL") #! Record("BSOC:LI03:G4:HWBypass_calc",260,18,0,1,"BSOC:LI03:G4:HWBypass_calc") #! Field("BSOC:LI03:G4:HWBypass_calc.INPA",16777215,0,"BSOC:LI03:G4:HWBypass_calc.INPA") #! Link("BSOC:LI03:G4:HWBypass_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb10.VAL") #! Field("BSOC:LI03:G4:HWBypass_calc.INPB",16777215,1,"BSOC:LI03:G4:HWBypass_calc.INPB") #! Field("BSOC:LI03:G4:HWBypass_calc.OUT",16777215,1,"BSOC:LI03:G4:HWBypass_calc.OUT") #! Link("BSOC:LI03:G4:HWBypass_calc.OUT","BSOC:LI03:G4:HWBypass.VAL") #! Record("BSOC:LI03:G4:HWBypass",500,20,0,0,"BSOC:LI03:G4:HWBypass") #! Field("BSOC:LI03:G4:HWBypass.VAL",16777215,1,"BSOC:LI03:G4:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi9") { field(DESC, "Port LI03_BSOIC_Rd bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:14N:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi9Valid") { field(INPA, "PLC:LI03:PP01:Bi9.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:14N:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:14N:Rad_calc") { field(INPA, "PLC:LI03:PP01:Bi9 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi9Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:14N:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:14N:Rad") { field(DESC, "BSOIC-RT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb9",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb9") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb9.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb9.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb9.FLNK","BSOC:LI04:14N:Rad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb9.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb9.VAL") #! Record("BSOC:LI04:14N:Rad_calc",260,18,0,1,"BSOC:LI04:14N:Rad_calc") #! Field("BSOC:LI04:14N:Rad_calc.INPA",16777215,0,"BSOC:LI04:14N:Rad_calc.INPA") #! Link("BSOC:LI04:14N:Rad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb9.VAL") #! Field("BSOC:LI04:14N:Rad_calc.INPB",16777215,1,"BSOC:LI04:14N:Rad_calc.INPB") #! Field("BSOC:LI04:14N:Rad_calc.OUT",16777215,1,"BSOC:LI04:14N:Rad_calc.OUT") #! Link("BSOC:LI04:14N:Rad_calc.OUT","BSOC:LI04:14N:Rad.VAL") #! Record("BSOC:LI04:14N:Rad",500,20,0,0,"BSOC:LI04:14N:Rad") #! Field("BSOC:LI04:14N:Rad.VAL",16777215,1,"BSOC:LI04:14N:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi8") { field(DESC, "Port LI03_BSOIC_Rd bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 8, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI04:14N:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi8Valid") { field(INPA, "PLC:LI03:PP01:Bi8.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:14N:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:14N:HWBypass_calc") { field(INPA, "PLC:LI03:PP01:Bi8 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi8Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:14N:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:14N:HWBypass") { field(DESC, "BSOIC-RT_N1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb8",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb8") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb8.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb8.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb8.FLNK","BSOC:LI04:14N:HWBypass_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb8.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb8.VAL") #! Record("BSOC:LI04:14N:HWBypass_calc",260,18,0,1,"BSOC:LI04:14N:HWBypass_calc") #! Field("BSOC:LI04:14N:HWBypass_calc.INPA",16777215,0,"BSOC:LI04:14N:HWBypass_calc.INPA") #! Link("BSOC:LI04:14N:HWBypass_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb8.VAL") #! Field("BSOC:LI04:14N:HWBypass_calc.INPB",16777215,1,"BSOC:LI04:14N:HWBypass_calc.INPB") #! Field("BSOC:LI04:14N:HWBypass_calc.OUT",16777215,1,"BSOC:LI04:14N:HWBypass_calc.OUT") #! Link("BSOC:LI04:14N:HWBypass_calc.OUT","BSOC:LI04:14N:HWBypass.VAL") #! Record("BSOC:LI04:14N:HWBypass",500,20,0,0,"BSOC:LI04:14N:HWBypass") #! Field("BSOC:LI04:14N:HWBypass.VAL",16777215,1,"BSOC:LI04:14N:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi23") { field(DESC, "Port LI03_BSOIC_Rd bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:15N:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi23Valid") { field(INPA, "PLC:LI03:PP01:Bi23.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:15N:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:15N:Rad_calc") { field(INPA, "PLC:LI03:PP01:Bi23 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi23Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:15N:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:15N:Rad") { field(DESC, "BSOIC-RT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb23",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb23") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb23.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb23.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb23.FLNK","BSOC:LI05:15N:Rad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb23.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb23.VAL") #! Record("BSOC:LI05:15N:Rad_calc",260,18,0,1,"BSOC:LI05:15N:Rad_calc") #! Field("BSOC:LI05:15N:Rad_calc.INPA",16777215,0,"BSOC:LI05:15N:Rad_calc.INPA") #! Link("BSOC:LI05:15N:Rad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb23.VAL") #! Field("BSOC:LI05:15N:Rad_calc.INPB",16777215,1,"BSOC:LI05:15N:Rad_calc.INPB") #! Field("BSOC:LI05:15N:Rad_calc.OUT",16777215,1,"BSOC:LI05:15N:Rad_calc.OUT") #! Link("BSOC:LI05:15N:Rad_calc.OUT","BSOC:LI05:15N:Rad.VAL") #! Record("BSOC:LI05:15N:Rad",500,20,0,0,"BSOC:LI05:15N:Rad") #! Field("BSOC:LI05:15N:Rad.VAL",16777215,1,"BSOC:LI05:15N:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi22") { field(DESC, "Port LI03_BSOIC_Rd bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 22, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI05:15N:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi22Valid") { field(INPA, "PLC:LI03:PP01:Bi22.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:15N:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:15N:HWBypass_calc") { field(INPA, "PLC:LI03:PP01:Bi22 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi22Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:15N:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:15N:HWBypass") { field(DESC, "BSOIC-RT_N2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb22",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb22") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb22.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb22.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb22.FLNK","BSOC:LI05:15N:HWBypass_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb22.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb22.VAL") #! Record("BSOC:LI05:15N:HWBypass_calc",260,18,0,1,"BSOC:LI05:15N:HWBypass_calc") #! Field("BSOC:LI05:15N:HWBypass_calc.INPA",16777215,0,"BSOC:LI05:15N:HWBypass_calc.INPA") #! Link("BSOC:LI05:15N:HWBypass_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb22.VAL") #! Field("BSOC:LI05:15N:HWBypass_calc.INPB",16777215,1,"BSOC:LI05:15N:HWBypass_calc.INPB") #! Field("BSOC:LI05:15N:HWBypass_calc.OUT",16777215,1,"BSOC:LI05:15N:HWBypass_calc.OUT") #! Link("BSOC:LI05:15N:HWBypass_calc.OUT","BSOC:LI05:15N:HWBypass.VAL") #! Record("BSOC:LI05:15N:HWBypass",500,20,0,0,"BSOC:LI05:15N:HWBypass") #! Field("BSOC:LI05:15N:HWBypass.VAL",16777215,1,"BSOC:LI05:15N:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi21") { field(DESC, "Port LI03_BSOIC_Rd bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi21Valid") { field(INPA, "PLC:LI03:PP01:Bi21.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:CascIn_calc") { field(INPA, "PLC:LI03:PP01:Bi21 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi21Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb21",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb21") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb21.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb21.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb21.FLNK","BSOC:LI03:1:CascIn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb21.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb21.VAL") #! Record("BSOC:LI03:1:CascIn_calc",260,18,0,1,"BSOC:LI03:1:CascIn_calc") #! Field("BSOC:LI03:1:CascIn_calc.INPA",16777215,0,"BSOC:LI03:1:CascIn_calc.INPA") #! Link("BSOC:LI03:1:CascIn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb21.VAL") #! Field("BSOC:LI03:1:CascIn_calc.INPB",16777215,1,"BSOC:LI03:1:CascIn_calc.INPB") #! Field("BSOC:LI03:1:CascIn_calc.OUT",16777215,1,"BSOC:LI03:1:CascIn_calc.OUT") #! Link("BSOC:LI03:1:CascIn_calc.OUT","BSOC:LI03:1:CascIn.VAL") #! Record("BSOC:LI03:1:CascIn",500,20,0,0,"BSOC:LI03:1:CascIn") #! Field("BSOC:LI03:1:CascIn.VAL",16777215,1,"BSOC:LI03:1:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi20") { field(DESC, "Port LI03_BSOIC_Rd bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:2:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi20Valid") { field(INPA, "PLC:LI03:PP01:Bi20.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:2:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:2:CascIn_calc") { field(INPA, "PLC:LI03:PP01:Bi20 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi20Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:2:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:2:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb20",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb20") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb20.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb20.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb20.FLNK","BSOC:LI03:2:CascIn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb20.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb20.VAL") #! Record("BSOC:LI03:2:CascIn_calc",260,18,0,1,"BSOC:LI03:2:CascIn_calc") #! Field("BSOC:LI03:2:CascIn_calc.INPA",16777215,0,"BSOC:LI03:2:CascIn_calc.INPA") #! Link("BSOC:LI03:2:CascIn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb20.VAL") #! Field("BSOC:LI03:2:CascIn_calc.INPB",16777215,1,"BSOC:LI03:2:CascIn_calc.INPB") #! Field("BSOC:LI03:2:CascIn_calc.OUT",16777215,1,"BSOC:LI03:2:CascIn_calc.OUT") #! Link("BSOC:LI03:2:CascIn_calc.OUT","BSOC:LI03:2:CascIn.VAL") #! Record("BSOC:LI03:2:CascIn",500,20,0,0,"BSOC:LI03:2:CascIn") #! Field("BSOC:LI03:2:CascIn.VAL",16777215,1,"BSOC:LI03:2:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi19") { field(DESC, "Port LI03_BSOIC_Rd bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 19, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI04:06:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi19Valid") { field(INPA, "PLC:LI03:PP01:Bi19.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:SoRstRb_calc") { field(INPA, "PLC:LI03:PP01:Bi19 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi19Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:SoRstRb") { field(DESC, "BSOIC-G1_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb19",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb19") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb19.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb19.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb19.FLNK","BSOC:LI04:06:SoRstRb_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb19.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb19.VAL") #! Record("BSOC:LI04:06:SoRstRb_calc",260,18,0,1,"BSOC:LI04:06:SoRstRb_calc") #! Field("BSOC:LI04:06:SoRstRb_calc.INPA",16777215,0,"BSOC:LI04:06:SoRstRb_calc.INPA") #! Link("BSOC:LI04:06:SoRstRb_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb19.VAL") #! Field("BSOC:LI04:06:SoRstRb_calc.INPB",16777215,1,"BSOC:LI04:06:SoRstRb_calc.INPB") #! Field("BSOC:LI04:06:SoRstRb_calc.OUT",16777215,1,"BSOC:LI04:06:SoRstRb_calc.OUT") #! Link("BSOC:LI04:06:SoRstRb_calc.OUT","BSOC:LI04:06:SoRstRb.VAL") #! Record("BSOC:LI04:06:SoRstRb",500,20,0,0,"BSOC:LI04:06:SoRstRb") #! Field("BSOC:LI04:06:SoRstRb.VAL",16777215,1,"BSOC:LI04:06:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi18") { field(DESC, "Port LI03_BSOIC_Rd bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 18, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI04:07:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi18Valid") { field(INPA, "PLC:LI03:PP01:Bi18.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:SoRstRb_calc") { field(INPA, "PLC:LI03:PP01:Bi18 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi18Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:SoRstRb") { field(DESC, "BSOIC-G2_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb18",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb18") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb18.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb18.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb18.FLNK","BSOC:LI04:07:SoRstRb_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb18.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb18.VAL") #! Record("BSOC:LI04:07:SoRstRb_calc",260,18,0,1,"BSOC:LI04:07:SoRstRb_calc") #! Field("BSOC:LI04:07:SoRstRb_calc.INPA",16777215,0,"BSOC:LI04:07:SoRstRb_calc.INPA") #! Link("BSOC:LI04:07:SoRstRb_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb18.VAL") #! Field("BSOC:LI04:07:SoRstRb_calc.INPB",16777215,1,"BSOC:LI04:07:SoRstRb_calc.INPB") #! Field("BSOC:LI04:07:SoRstRb_calc.OUT",16777215,1,"BSOC:LI04:07:SoRstRb_calc.OUT") #! Link("BSOC:LI04:07:SoRstRb_calc.OUT","BSOC:LI04:07:SoRstRb.VAL") #! Record("BSOC:LI04:07:SoRstRb",500,20,0,0,"BSOC:LI04:07:SoRstRb") #! Field("BSOC:LI04:07:SoRstRb.VAL",16777215,1,"BSOC:LI04:07:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi17") { field(DESC, "Port LI03_BSOIC_Rd bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 17, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI05:08:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi17Valid") { field(INPA, "PLC:LI03:PP01:Bi17.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:SoRstRb_calc") { field(INPA, "PLC:LI03:PP01:Bi17 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi17Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:SoRstRb") { field(DESC, "BSOIC-G3_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb17",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb17") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb17.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb17.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb17.FLNK","BSOC:LI05:08:SoRstRb_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb17.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb17.VAL") #! Record("BSOC:LI05:08:SoRstRb_calc",260,18,0,1,"BSOC:LI05:08:SoRstRb_calc") #! Field("BSOC:LI05:08:SoRstRb_calc.INPA",16777215,0,"BSOC:LI05:08:SoRstRb_calc.INPA") #! Link("BSOC:LI05:08:SoRstRb_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb17.VAL") #! Field("BSOC:LI05:08:SoRstRb_calc.INPB",16777215,1,"BSOC:LI05:08:SoRstRb_calc.INPB") #! Field("BSOC:LI05:08:SoRstRb_calc.OUT",16777215,1,"BSOC:LI05:08:SoRstRb_calc.OUT") #! Link("BSOC:LI05:08:SoRstRb_calc.OUT","BSOC:LI05:08:SoRstRb.VAL") #! Record("BSOC:LI05:08:SoRstRb",500,20,0,0,"BSOC:LI05:08:SoRstRb") #! Field("BSOC:LI05:08:SoRstRb.VAL",16777215,1,"BSOC:LI05:08:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi16") { field(DESC, "Port LI03_BSOIC_Rd bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 16, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI03:G4:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi16Valid") { field(INPA, "PLC:LI03:PP01:Bi16.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:SoRstRb_calc") { field(INPA, "PLC:LI03:PP01:Bi16 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi16Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:SoRstRb") { field(DESC, "BSOIC-G4_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb16",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb16") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb16.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb16.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb16.FLNK","BSOC:LI03:G4:SoRstRb_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb16.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb16.VAL") #! Record("BSOC:LI03:G4:SoRstRb_calc",260,18,0,1,"BSOC:LI03:G4:SoRstRb_calc") #! Field("BSOC:LI03:G4:SoRstRb_calc.INPA",16777215,0,"BSOC:LI03:G4:SoRstRb_calc.INPA") #! Link("BSOC:LI03:G4:SoRstRb_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb16.VAL") #! Field("BSOC:LI03:G4:SoRstRb_calc.INPB",16777215,1,"BSOC:LI03:G4:SoRstRb_calc.INPB") #! Field("BSOC:LI03:G4:SoRstRb_calc.OUT",16777215,1,"BSOC:LI03:G4:SoRstRb_calc.OUT") #! Link("BSOC:LI03:G4:SoRstRb_calc.OUT","BSOC:LI03:G4:SoRstRb.VAL") #! Record("BSOC:LI03:G4:SoRstRb",500,20,0,0,"BSOC:LI03:G4:SoRstRb") #! Field("BSOC:LI03:G4:SoRstRb.VAL",16777215,1,"BSOC:LI03:G4:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi95") { field(DESC, "Port LI03_BSOIC_Rd bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 95, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI03:1:AnnAlarm_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi95Valid") { field(INPA, "PLC:LI03:PP01:Bi95.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:AnnAlarm_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:AnnAlarm_calc") { field(INPA, "PLC:LI03:PP01:Bi95 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi95Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:AnnAlarm PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:AnnAlarm") { field(DESC, "BSOIC-HW_Annunciator_Alarm") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb95",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb95") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb95.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb95.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb95.FLNK","BSOC:LI03:1:AnnAlarm_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb95.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb95.VAL") #! Record("BSOC:LI03:1:AnnAlarm_calc",260,18,0,1,"BSOC:LI03:1:AnnAlarm_calc") #! Field("BSOC:LI03:1:AnnAlarm_calc.INPA",16777215,0,"BSOC:LI03:1:AnnAlarm_calc.INPA") #! Link("BSOC:LI03:1:AnnAlarm_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb95.VAL") #! Field("BSOC:LI03:1:AnnAlarm_calc.INPB",16777215,1,"BSOC:LI03:1:AnnAlarm_calc.INPB") #! Field("BSOC:LI03:1:AnnAlarm_calc.OUT",16777215,1,"BSOC:LI03:1:AnnAlarm_calc.OUT") #! Link("BSOC:LI03:1:AnnAlarm_calc.OUT","BSOC:LI03:1:AnnAlarm.VAL") #! Record("BSOC:LI03:1:AnnAlarm",500,20,0,0,"BSOC:LI03:1:AnnAlarm") #! Field("BSOC:LI03:1:AnnAlarm.VAL",16777215,1,"BSOC:LI03:1:AnnAlarm.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi94") { field(DESC, "Port LI03_BSOIC_Rd bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 94, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI03:1:CascOut_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi94Valid") { field(INPA, "PLC:LI03:PP01:Bi94.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:CascOut_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:CascOut_calc") { field(INPA, "PLC:LI03:PP01:Bi94 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi94Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:CascOut PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:CascOut") { field(DESC, "BSOIC-HW_Cascade_Out") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb94",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb94") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb94.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb94.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb94.FLNK","BSOC:LI03:1:CascOut_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb94.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb94.VAL") #! Record("BSOC:LI03:1:CascOut_calc",260,18,0,1,"BSOC:LI03:1:CascOut_calc") #! Field("BSOC:LI03:1:CascOut_calc.INPA",16777215,0,"BSOC:LI03:1:CascOut_calc.INPA") #! Link("BSOC:LI03:1:CascOut_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb94.VAL") #! Field("BSOC:LI03:1:CascOut_calc.INPB",16777215,1,"BSOC:LI03:1:CascOut_calc.INPB") #! Field("BSOC:LI03:1:CascOut_calc.OUT",16777215,1,"BSOC:LI03:1:CascOut_calc.OUT") #! Link("BSOC:LI03:1:CascOut_calc.OUT","BSOC:LI03:1:CascOut.VAL") #! Record("BSOC:LI03:1:CascOut",500,20,0,0,"BSOC:LI03:1:CascOut") #! Field("BSOC:LI03:1:CascOut.VAL",16777215,1,"BSOC:LI03:1:CascOut.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi93") { field(DESC, "Port LI03_BSOIC_Rd bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:HWSfOut1_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi93Valid") { field(INPA, "PLC:LI03:PP01:Bi93.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:HWSfOut1_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:HWSfOut1_calc") { field(INPA, "PLC:LI03:PP01:Bi93 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi93Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:HWSfOut1 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:HWSfOut1") { field(DESC, "BSOIC-HW_Safety_Out1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb93",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb93") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb93.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb93.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb93.FLNK","BSOC:LI03:1:HWSfOut1_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb93.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb93.VAL") #! Record("BSOC:LI03:1:HWSfOut1_calc",260,18,0,1,"BSOC:LI03:1:HWSfOut1_calc") #! Field("BSOC:LI03:1:HWSfOut1_calc.INPA",16777215,0,"BSOC:LI03:1:HWSfOut1_calc.INPA") #! Link("BSOC:LI03:1:HWSfOut1_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb93.VAL") #! Field("BSOC:LI03:1:HWSfOut1_calc.INPB",16777215,1,"BSOC:LI03:1:HWSfOut1_calc.INPB") #! Field("BSOC:LI03:1:HWSfOut1_calc.OUT",16777215,1,"BSOC:LI03:1:HWSfOut1_calc.OUT") #! Link("BSOC:LI03:1:HWSfOut1_calc.OUT","BSOC:LI03:1:HWSfOut1.VAL") #! Record("BSOC:LI03:1:HWSfOut1",500,20,0,0,"BSOC:LI03:1:HWSfOut1") #! Field("BSOC:LI03:1:HWSfOut1.VAL",16777215,1,"BSOC:LI03:1:HWSfOut1.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi92") { field(DESC, "Port LI03_BSOIC_Rd bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:HWSfOut2_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi92Valid") { field(INPA, "PLC:LI03:PP01:Bi92.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:HWSfOut2_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:HWSfOut2_calc") { field(INPA, "PLC:LI03:PP01:Bi92 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi92Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:HWSfOut2 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:HWSfOut2") { field(DESC, "BSOIC-HW_Safety_Out2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb92",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb92") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb92.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb92.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb92.FLNK","BSOC:LI03:1:HWSfOut2_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb92.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb92.VAL") #! Record("BSOC:LI03:1:HWSfOut2_calc",260,18,0,1,"BSOC:LI03:1:HWSfOut2_calc") #! Field("BSOC:LI03:1:HWSfOut2_calc.INPA",16777215,0,"BSOC:LI03:1:HWSfOut2_calc.INPA") #! Link("BSOC:LI03:1:HWSfOut2_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb92.VAL") #! Field("BSOC:LI03:1:HWSfOut2_calc.INPB",16777215,1,"BSOC:LI03:1:HWSfOut2_calc.INPB") #! Field("BSOC:LI03:1:HWSfOut2_calc.OUT",16777215,1,"BSOC:LI03:1:HWSfOut2_calc.OUT") #! Link("BSOC:LI03:1:HWSfOut2_calc.OUT","BSOC:LI03:1:HWSfOut2.VAL") #! Record("BSOC:LI03:1:HWSfOut2",500,20,0,0,"BSOC:LI03:1:HWSfOut2") #! Field("BSOC:LI03:1:HWSfOut2.VAL",16777215,1,"BSOC:LI03:1:HWSfOut2.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi91") { field(DESC, "Port LI03_BSOIC_Rd bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:HWSfOut3_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi91Valid") { field(INPA, "PLC:LI03:PP01:Bi91.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:HWSfOut3_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:HWSfOut3_calc") { field(INPA, "PLC:LI03:PP01:Bi91 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi91Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:HWSfOut3 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:HWSfOut3") { field(DESC, "BSOIC-HW_Safety_Out3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb91",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb91") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb91.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb91.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb91.FLNK","BSOC:LI03:1:HWSfOut3_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb91.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb91.VAL") #! Record("BSOC:LI03:1:HWSfOut3_calc",260,18,0,1,"BSOC:LI03:1:HWSfOut3_calc") #! Field("BSOC:LI03:1:HWSfOut3_calc.INPA",16777215,0,"BSOC:LI03:1:HWSfOut3_calc.INPA") #! Link("BSOC:LI03:1:HWSfOut3_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb91.VAL") #! Field("BSOC:LI03:1:HWSfOut3_calc.INPB",16777215,1,"BSOC:LI03:1:HWSfOut3_calc.INPB") #! Field("BSOC:LI03:1:HWSfOut3_calc.OUT",16777215,1,"BSOC:LI03:1:HWSfOut3_calc.OUT") #! Link("BSOC:LI03:1:HWSfOut3_calc.OUT","BSOC:LI03:1:HWSfOut3.VAL") #! Record("BSOC:LI03:1:HWSfOut3",500,20,0,0,"BSOC:LI03:1:HWSfOut3") #! Field("BSOC:LI03:1:HWSfOut3.VAL",16777215,1,"BSOC:LI03:1:HWSfOut3.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi90") { field(DESC, "Port LI03_BSOIC_Rd bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:HWSfOut4_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi90Valid") { field(INPA, "PLC:LI03:PP01:Bi90.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:HWSfOut4_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:HWSfOut4_calc") { field(INPA, "PLC:LI03:PP01:Bi90 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi90Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:HWSfOut4 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:HWSfOut4") { field(DESC, "BSOIC-HW_Safety_Out4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb90",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb90") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb90.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb90.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb90.FLNK","BSOC:LI03:1:HWSfOut4_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb90.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb90.VAL") #! Record("BSOC:LI03:1:HWSfOut4_calc",260,18,0,1,"BSOC:LI03:1:HWSfOut4_calc") #! Field("BSOC:LI03:1:HWSfOut4_calc.INPA",16777215,0,"BSOC:LI03:1:HWSfOut4_calc.INPA") #! Link("BSOC:LI03:1:HWSfOut4_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb90.VAL") #! Field("BSOC:LI03:1:HWSfOut4_calc.INPB",16777215,1,"BSOC:LI03:1:HWSfOut4_calc.INPB") #! Field("BSOC:LI03:1:HWSfOut4_calc.OUT",16777215,1,"BSOC:LI03:1:HWSfOut4_calc.OUT") #! Link("BSOC:LI03:1:HWSfOut4_calc.OUT","BSOC:LI03:1:HWSfOut4.VAL") #! Record("BSOC:LI03:1:HWSfOut4",500,20,0,0,"BSOC:LI03:1:HWSfOut4") #! Field("BSOC:LI03:1:HWSfOut4.VAL",16777215,1,"BSOC:LI03:1:HWSfOut4.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi89") { field(DESC, "Port LI03_BSOIC_Rd bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:06:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi89Valid") { field(INPA, "PLC:LI03:PP01:Bi89.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:LatEqp_calc") { field(INPA, "PLC:LI03:PP01:Bi89 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi89Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:LatEqp") { field(DESC, "BSOIC-LAT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb89",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb89") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb89.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb89.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb89.FLNK","BSOC:LI04:06:LatEqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb89.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb89.VAL") #! Record("BSOC:LI04:06:LatEqp_calc",260,18,0,1,"BSOC:LI04:06:LatEqp_calc") #! Field("BSOC:LI04:06:LatEqp_calc.INPA",16777215,0,"BSOC:LI04:06:LatEqp_calc.INPA") #! Link("BSOC:LI04:06:LatEqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb89.VAL") #! Field("BSOC:LI04:06:LatEqp_calc.INPB",16777215,1,"BSOC:LI04:06:LatEqp_calc.INPB") #! Field("BSOC:LI04:06:LatEqp_calc.OUT",16777215,1,"BSOC:LI04:06:LatEqp_calc.OUT") #! Link("BSOC:LI04:06:LatEqp_calc.OUT","BSOC:LI04:06:LatEqp.VAL") #! Record("BSOC:LI04:06:LatEqp",500,20,0,0,"BSOC:LI04:06:LatEqp") #! Field("BSOC:LI04:06:LatEqp.VAL",16777215,1,"BSOC:LI04:06:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi88") { field(DESC, "Port LI03_BSOIC_Rd bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:06:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi88Valid") { field(INPA, "PLC:LI03:PP01:Bi88.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:LatRad_calc") { field(INPA, "PLC:LI03:PP01:Bi88 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi88Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:LatRad") { field(DESC, "BSOIC-LAT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb88",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb88") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb88.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb88.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb88.FLNK","BSOC:LI04:06:LatRad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb88.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb88.VAL") #! Record("BSOC:LI04:06:LatRad_calc",260,18,0,1,"BSOC:LI04:06:LatRad_calc") #! Field("BSOC:LI04:06:LatRad_calc.INPA",16777215,0,"BSOC:LI04:06:LatRad_calc.INPA") #! Link("BSOC:LI04:06:LatRad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb88.VAL") #! Field("BSOC:LI04:06:LatRad_calc.INPB",16777215,1,"BSOC:LI04:06:LatRad_calc.INPB") #! Field("BSOC:LI04:06:LatRad_calc.OUT",16777215,1,"BSOC:LI04:06:LatRad_calc.OUT") #! Link("BSOC:LI04:06:LatRad_calc.OUT","BSOC:LI04:06:LatRad.VAL") #! Record("BSOC:LI04:06:LatRad",500,20,0,0,"BSOC:LI04:06:LatRad") #! Field("BSOC:LI04:06:LatRad.VAL",16777215,1,"BSOC:LI04:06:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi103") { field(DESC, "Port LI03_BSOIC_Rd bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:07:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi103Valid") { field(INPA, "PLC:LI03:PP01:Bi103.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:LatEqp_calc") { field(INPA, "PLC:LI03:PP01:Bi103 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi103Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:LatEqp") { field(DESC, "BSOIC-LAT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb103",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb103") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb103.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb103.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb103.FLNK","BSOC:LI04:07:LatEqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb103.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb103.VAL") #! Record("BSOC:LI04:07:LatEqp_calc",260,18,0,1,"BSOC:LI04:07:LatEqp_calc") #! Field("BSOC:LI04:07:LatEqp_calc.INPA",16777215,0,"BSOC:LI04:07:LatEqp_calc.INPA") #! Link("BSOC:LI04:07:LatEqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb103.VAL") #! Field("BSOC:LI04:07:LatEqp_calc.INPB",16777215,1,"BSOC:LI04:07:LatEqp_calc.INPB") #! Field("BSOC:LI04:07:LatEqp_calc.OUT",16777215,1,"BSOC:LI04:07:LatEqp_calc.OUT") #! Link("BSOC:LI04:07:LatEqp_calc.OUT","BSOC:LI04:07:LatEqp.VAL") #! Record("BSOC:LI04:07:LatEqp",500,20,0,0,"BSOC:LI04:07:LatEqp") #! Field("BSOC:LI04:07:LatEqp.VAL",16777215,1,"BSOC:LI04:07:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi102") { field(DESC, "Port LI03_BSOIC_Rd bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:07:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi102Valid") { field(INPA, "PLC:LI03:PP01:Bi102.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:LatRad_calc") { field(INPA, "PLC:LI03:PP01:Bi102 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi102Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:LatRad") { field(DESC, "BSOIC-LAT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb102",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb102") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb102.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb102.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb102.FLNK","BSOC:LI04:07:LatRad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb102.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb102.VAL") #! Record("BSOC:LI04:07:LatRad_calc",260,18,0,1,"BSOC:LI04:07:LatRad_calc") #! Field("BSOC:LI04:07:LatRad_calc.INPA",16777215,0,"BSOC:LI04:07:LatRad_calc.INPA") #! Link("BSOC:LI04:07:LatRad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb102.VAL") #! Field("BSOC:LI04:07:LatRad_calc.INPB",16777215,1,"BSOC:LI04:07:LatRad_calc.INPB") #! Field("BSOC:LI04:07:LatRad_calc.OUT",16777215,1,"BSOC:LI04:07:LatRad_calc.OUT") #! Link("BSOC:LI04:07:LatRad_calc.OUT","BSOC:LI04:07:LatRad.VAL") #! Record("BSOC:LI04:07:LatRad",500,20,0,0,"BSOC:LI04:07:LatRad") #! Field("BSOC:LI04:07:LatRad.VAL",16777215,1,"BSOC:LI04:07:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi101") { field(DESC, "Port LI03_BSOIC_Rd bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:08:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi101Valid") { field(INPA, "PLC:LI03:PP01:Bi101.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:LatEqp_calc") { field(INPA, "PLC:LI03:PP01:Bi101 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi101Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:LatEqp") { field(DESC, "BSOIC-LAT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb101",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb101") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb101.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb101.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb101.FLNK","BSOC:LI05:08:LatEqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb101.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb101.VAL") #! Record("BSOC:LI05:08:LatEqp_calc",260,18,0,1,"BSOC:LI05:08:LatEqp_calc") #! Field("BSOC:LI05:08:LatEqp_calc.INPA",16777215,0,"BSOC:LI05:08:LatEqp_calc.INPA") #! Link("BSOC:LI05:08:LatEqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb101.VAL") #! Field("BSOC:LI05:08:LatEqp_calc.INPB",16777215,1,"BSOC:LI05:08:LatEqp_calc.INPB") #! Field("BSOC:LI05:08:LatEqp_calc.OUT",16777215,1,"BSOC:LI05:08:LatEqp_calc.OUT") #! Link("BSOC:LI05:08:LatEqp_calc.OUT","BSOC:LI05:08:LatEqp.VAL") #! Record("BSOC:LI05:08:LatEqp",500,20,0,0,"BSOC:LI05:08:LatEqp") #! Field("BSOC:LI05:08:LatEqp.VAL",16777215,1,"BSOC:LI05:08:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi100") { field(DESC, "Port LI03_BSOIC_Rd bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:08:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi100Valid") { field(INPA, "PLC:LI03:PP01:Bi100.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:LatRad_calc") { field(INPA, "PLC:LI03:PP01:Bi100 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi100Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:LatRad") { field(DESC, "BSOIC-LAT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb100",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb100") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb100.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb100.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb100.FLNK","BSOC:LI05:08:LatRad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb100.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb100.VAL") #! Record("BSOC:LI05:08:LatRad_calc",260,18,0,1,"BSOC:LI05:08:LatRad_calc") #! Field("BSOC:LI05:08:LatRad_calc.INPA",16777215,0,"BSOC:LI05:08:LatRad_calc.INPA") #! Link("BSOC:LI05:08:LatRad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb100.VAL") #! Field("BSOC:LI05:08:LatRad_calc.INPB",16777215,1,"BSOC:LI05:08:LatRad_calc.INPB") #! Field("BSOC:LI05:08:LatRad_calc.OUT",16777215,1,"BSOC:LI05:08:LatRad_calc.OUT") #! Link("BSOC:LI05:08:LatRad_calc.OUT","BSOC:LI05:08:LatRad.VAL") #! Record("BSOC:LI05:08:LatRad",500,20,0,0,"BSOC:LI05:08:LatRad") #! Field("BSOC:LI05:08:LatRad.VAL",16777215,1,"BSOC:LI05:08:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi99") { field(DESC, "Port LI03_BSOIC_Rd bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:G4:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi99Valid") { field(INPA, "PLC:LI03:PP01:Bi99.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:LatEqp_calc") { field(INPA, "PLC:LI03:PP01:Bi99 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi99Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:LatEqp") { field(DESC, "BSOIC-LAT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb99",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb99") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb99.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb99.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb99.FLNK","BSOC:LI03:G4:LatEqp_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb99.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb99.VAL") #! Record("BSOC:LI03:G4:LatEqp_calc",260,18,0,1,"BSOC:LI03:G4:LatEqp_calc") #! Field("BSOC:LI03:G4:LatEqp_calc.INPA",16777215,0,"BSOC:LI03:G4:LatEqp_calc.INPA") #! Link("BSOC:LI03:G4:LatEqp_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb99.VAL") #! Field("BSOC:LI03:G4:LatEqp_calc.INPB",16777215,1,"BSOC:LI03:G4:LatEqp_calc.INPB") #! Field("BSOC:LI03:G4:LatEqp_calc.OUT",16777215,1,"BSOC:LI03:G4:LatEqp_calc.OUT") #! Link("BSOC:LI03:G4:LatEqp_calc.OUT","BSOC:LI03:G4:LatEqp.VAL") #! Record("BSOC:LI03:G4:LatEqp",500,20,0,0,"BSOC:LI03:G4:LatEqp") #! Field("BSOC:LI03:G4:LatEqp.VAL",16777215,1,"BSOC:LI03:G4:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi98") { field(DESC, "Port LI03_BSOIC_Rd bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:G4:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi98Valid") { field(INPA, "PLC:LI03:PP01:Bi98.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:LatRad_calc") { field(INPA, "PLC:LI03:PP01:Bi98 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi98Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:LatRad") { field(DESC, "BSOIC-LAT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb98",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb98") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb98.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb98.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb98.FLNK","BSOC:LI03:G4:LatRad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb98.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb98.VAL") #! Record("BSOC:LI03:G4:LatRad_calc",260,18,0,1,"BSOC:LI03:G4:LatRad_calc") #! Field("BSOC:LI03:G4:LatRad_calc.INPA",16777215,0,"BSOC:LI03:G4:LatRad_calc.INPA") #! Link("BSOC:LI03:G4:LatRad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb98.VAL") #! Field("BSOC:LI03:G4:LatRad_calc.INPB",16777215,1,"BSOC:LI03:G4:LatRad_calc.INPB") #! Field("BSOC:LI03:G4:LatRad_calc.OUT",16777215,1,"BSOC:LI03:G4:LatRad_calc.OUT") #! Link("BSOC:LI03:G4:LatRad_calc.OUT","BSOC:LI03:G4:LatRad.VAL") #! Record("BSOC:LI03:G4:LatRad",500,20,0,0,"BSOC:LI03:G4:LatRad") #! Field("BSOC:LI03:G4:LatRad.VAL",16777215,1,"BSOC:LI03:G4:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi97") { field(DESC, "Port LI03_BSOIC_Rd bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:14N:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi97Valid") { field(INPA, "PLC:LI03:PP01:Bi97.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:14N:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:14N:LatRad_calc") { field(INPA, "PLC:LI03:PP01:Bi97 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi97Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:14N:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:14N:LatRad") { field(DESC, "BSOIC-LAT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb97",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb97") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb97.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb97.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb97.FLNK","BSOC:LI04:14N:LatRad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb97.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb97.VAL") #! Record("BSOC:LI04:14N:LatRad_calc",260,18,0,1,"BSOC:LI04:14N:LatRad_calc") #! Field("BSOC:LI04:14N:LatRad_calc.INPA",16777215,0,"BSOC:LI04:14N:LatRad_calc.INPA") #! Link("BSOC:LI04:14N:LatRad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb97.VAL") #! Field("BSOC:LI04:14N:LatRad_calc.INPB",16777215,1,"BSOC:LI04:14N:LatRad_calc.INPB") #! Field("BSOC:LI04:14N:LatRad_calc.OUT",16777215,1,"BSOC:LI04:14N:LatRad_calc.OUT") #! Link("BSOC:LI04:14N:LatRad_calc.OUT","BSOC:LI04:14N:LatRad.VAL") #! Record("BSOC:LI04:14N:LatRad",500,20,0,0,"BSOC:LI04:14N:LatRad") #! Field("BSOC:LI04:14N:LatRad.VAL",16777215,1,"BSOC:LI04:14N:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi96") { field(DESC, "Port LI03_BSOIC_Rd bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:15N:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi96Valid") { field(INPA, "PLC:LI03:PP01:Bi96.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:15N:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:15N:LatRad_calc") { field(INPA, "PLC:LI03:PP01:Bi96 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi96Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:15N:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:15N:LatRad") { field(DESC, "BSOIC-LAT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb96",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb96") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb96.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb96.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb96.FLNK","BSOC:LI05:15N:LatRad_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb96.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb96.VAL") #! Record("BSOC:LI05:15N:LatRad_calc",260,18,0,1,"BSOC:LI05:15N:LatRad_calc") #! Field("BSOC:LI05:15N:LatRad_calc.INPA",16777215,0,"BSOC:LI05:15N:LatRad_calc.INPA") #! Link("BSOC:LI05:15N:LatRad_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb96.VAL") #! Field("BSOC:LI05:15N:LatRad_calc.INPB",16777215,1,"BSOC:LI05:15N:LatRad_calc.INPB") #! Field("BSOC:LI05:15N:LatRad_calc.OUT",16777215,1,"BSOC:LI05:15N:LatRad_calc.OUT") #! Link("BSOC:LI05:15N:LatRad_calc.OUT","BSOC:LI05:15N:LatRad.VAL") #! Record("BSOC:LI05:15N:LatRad",500,20,0,0,"BSOC:LI05:15N:LatRad") #! Field("BSOC:LI05:15N:LatRad.VAL",16777215,1,"BSOC:LI05:15N:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi111") { field(DESC, "Port LI03_BSOIC_Rd bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi111Valid") { field(INPA, "PLC:LI03:PP01:Bi111.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:LatCascIn_calc") { field(INPA, "PLC:LI03:PP01:Bi111 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi111Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb111",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb111") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb111.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb111.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb111.FLNK","BSOC:LI03:1:LatCascIn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb111.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb111.VAL") #! Record("BSOC:LI03:1:LatCascIn_calc",260,18,0,1,"BSOC:LI03:1:LatCascIn_calc") #! Field("BSOC:LI03:1:LatCascIn_calc.INPA",16777215,0,"BSOC:LI03:1:LatCascIn_calc.INPA") #! Link("BSOC:LI03:1:LatCascIn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb111.VAL") #! Field("BSOC:LI03:1:LatCascIn_calc.INPB",16777215,1,"BSOC:LI03:1:LatCascIn_calc.INPB") #! Field("BSOC:LI03:1:LatCascIn_calc.OUT",16777215,1,"BSOC:LI03:1:LatCascIn_calc.OUT") #! Link("BSOC:LI03:1:LatCascIn_calc.OUT","BSOC:LI03:1:LatCascIn.VAL") #! Record("BSOC:LI03:1:LatCascIn",500,20,0,0,"BSOC:LI03:1:LatCascIn") #! Field("BSOC:LI03:1:LatCascIn.VAL",16777215,1,"BSOC:LI03:1:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi110") { field(DESC, "Port LI03_BSOIC_Rd bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:2:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi110Valid") { field(INPA, "PLC:LI03:PP01:Bi110.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:2:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:2:LatCascIn_calc") { field(INPA, "PLC:LI03:PP01:Bi110 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi110Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:2:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:2:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb110",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb110") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb110.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb110.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb110.FLNK","BSOC:LI03:2:LatCascIn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb110.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb110.VAL") #! Record("BSOC:LI03:2:LatCascIn_calc",260,18,0,1,"BSOC:LI03:2:LatCascIn_calc") #! Field("BSOC:LI03:2:LatCascIn_calc.INPA",16777215,0,"BSOC:LI03:2:LatCascIn_calc.INPA") #! Link("BSOC:LI03:2:LatCascIn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb110.VAL") #! Field("BSOC:LI03:2:LatCascIn_calc.INPB",16777215,1,"BSOC:LI03:2:LatCascIn_calc.INPB") #! Field("BSOC:LI03:2:LatCascIn_calc.OUT",16777215,1,"BSOC:LI03:2:LatCascIn_calc.OUT") #! Link("BSOC:LI03:2:LatCascIn_calc.OUT","BSOC:LI03:2:LatCascIn.VAL") #! Record("BSOC:LI03:2:LatCascIn",500,20,0,0,"BSOC:LI03:2:LatCascIn") #! Field("BSOC:LI03:2:LatCascIn.VAL",16777215,1,"BSOC:LI03:2:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi109") { field(DESC, "Port LI03_BSOIC_Rd bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:AllGOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi109Valid") { field(INPA, "PLC:LI03:PP01:Bi109.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:AllGOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:AllGOk_calc") { field(INPA, "PLC:LI03:PP01:Bi109 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi109Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:AllGOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:AllGOk") { field(DESC, "BSOIC-All_Gamma_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb109",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb109") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb109.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb109.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb109.FLNK","BSOC:LI03:1:AllGOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb109.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb109.VAL") #! Record("BSOC:LI03:1:AllGOk_calc",260,18,0,1,"BSOC:LI03:1:AllGOk_calc") #! Field("BSOC:LI03:1:AllGOk_calc.INPA",16777215,0,"BSOC:LI03:1:AllGOk_calc.INPA") #! Link("BSOC:LI03:1:AllGOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb109.VAL") #! Field("BSOC:LI03:1:AllGOk_calc.INPB",16777215,1,"BSOC:LI03:1:AllGOk_calc.INPB") #! Field("BSOC:LI03:1:AllGOk_calc.OUT",16777215,1,"BSOC:LI03:1:AllGOk_calc.OUT") #! Link("BSOC:LI03:1:AllGOk_calc.OUT","BSOC:LI03:1:AllGOk.VAL") #! Record("BSOC:LI03:1:AllGOk",500,20,0,0,"BSOC:LI03:1:AllGOk") #! Field("BSOC:LI03:1:AllGOk.VAL",16777215,1,"BSOC:LI03:1:AllGOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi108") { field(DESC, "Port LI03_BSOIC_Rd bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 108, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:AllNOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi108Valid") { field(INPA, "PLC:LI03:PP01:Bi108.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:AllNOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:AllNOk_calc") { field(INPA, "PLC:LI03:PP01:Bi108 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi108Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:AllNOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:AllNOk") { field(DESC, "BSOIC-All_Neutron_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb108",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb108") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb108.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb108.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb108.FLNK","BSOC:LI03:1:AllNOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb108.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb108.VAL") #! Record("BSOC:LI03:1:AllNOk_calc",260,18,0,1,"BSOC:LI03:1:AllNOk_calc") #! Field("BSOC:LI03:1:AllNOk_calc.INPA",16777215,0,"BSOC:LI03:1:AllNOk_calc.INPA") #! Link("BSOC:LI03:1:AllNOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb108.VAL") #! Field("BSOC:LI03:1:AllNOk_calc.INPB",16777215,1,"BSOC:LI03:1:AllNOk_calc.INPB") #! Field("BSOC:LI03:1:AllNOk_calc.OUT",16777215,1,"BSOC:LI03:1:AllNOk_calc.OUT") #! Link("BSOC:LI03:1:AllNOk_calc.OUT","BSOC:LI03:1:AllNOk.VAL") #! Record("BSOC:LI03:1:AllNOk",500,20,0,0,"BSOC:LI03:1:AllNOk") #! Field("BSOC:LI03:1:AllNOk.VAL",16777215,1,"BSOC:LI03:1:AllNOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi107") { field(DESC, "Port LI03_BSOIC_Rd bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:1:AllOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi107Valid") { field(INPA, "PLC:LI03:PP01:Bi107.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:AllOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:AllOk_calc") { field(INPA, "PLC:LI03:PP01:Bi107 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi107Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:AllOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:AllOk") { field(DESC, "BSOIC-All_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb107",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb107") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb107.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb107.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb107.FLNK","BSOC:LI03:1:AllOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb107.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb107.VAL") #! Record("BSOC:LI03:1:AllOk_calc",260,18,0,1,"BSOC:LI03:1:AllOk_calc") #! Field("BSOC:LI03:1:AllOk_calc.INPA",16777215,0,"BSOC:LI03:1:AllOk_calc.INPA") #! Link("BSOC:LI03:1:AllOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb107.VAL") #! Field("BSOC:LI03:1:AllOk_calc.INPB",16777215,1,"BSOC:LI03:1:AllOk_calc.INPB") #! Field("BSOC:LI03:1:AllOk_calc.OUT",16777215,1,"BSOC:LI03:1:AllOk_calc.OUT") #! Link("BSOC:LI03:1:AllOk_calc.OUT","BSOC:LI03:1:AllOk.VAL") #! Record("BSOC:LI03:1:AllOk",500,20,0,0,"BSOC:LI03:1:AllOk") #! Field("BSOC:LI03:1:AllOk.VAL",16777215,1,"BSOC:LI03:1:AllOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi106") { field(DESC, "Port LI03_BSOIC_Rd bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 106, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI04:06:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi106Valid") { field(INPA, "PLC:LI03:PP01:Bi106.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:EqpWarn_calc") { field(INPA, "PLC:LI03:PP01:Bi106 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi106Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb106",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb106") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb106.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb106.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb106.FLNK","BSOC:LI04:06:EqpWarn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb106.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb106.VAL") #! Record("BSOC:LI04:06:EqpWarn_calc",260,18,0,1,"BSOC:LI04:06:EqpWarn_calc") #! Field("BSOC:LI04:06:EqpWarn_calc.INPA",16777215,0,"BSOC:LI04:06:EqpWarn_calc.INPA") #! Link("BSOC:LI04:06:EqpWarn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb106.VAL") #! Field("BSOC:LI04:06:EqpWarn_calc.INPB",16777215,1,"BSOC:LI04:06:EqpWarn_calc.INPB") #! Field("BSOC:LI04:06:EqpWarn_calc.OUT",16777215,1,"BSOC:LI04:06:EqpWarn_calc.OUT") #! Link("BSOC:LI04:06:EqpWarn_calc.OUT","BSOC:LI04:06:EqpWarn.VAL") #! Record("BSOC:LI04:06:EqpWarn",500,20,0,0,"BSOC:LI04:06:EqpWarn") #! Field("BSOC:LI04:06:EqpWarn.VAL",16777215,1,"BSOC:LI04:06:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi105") { field(DESC, "Port LI03_BSOIC_Rd bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 105, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI04:07:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi105Valid") { field(INPA, "PLC:LI03:PP01:Bi105.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:EqpWarn_calc") { field(INPA, "PLC:LI03:PP01:Bi105 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi105Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb105",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb105") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb105.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb105.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb105.FLNK","BSOC:LI04:07:EqpWarn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb105.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb105.VAL") #! Record("BSOC:LI04:07:EqpWarn_calc",260,18,0,1,"BSOC:LI04:07:EqpWarn_calc") #! Field("BSOC:LI04:07:EqpWarn_calc.INPA",16777215,0,"BSOC:LI04:07:EqpWarn_calc.INPA") #! Link("BSOC:LI04:07:EqpWarn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb105.VAL") #! Field("BSOC:LI04:07:EqpWarn_calc.INPB",16777215,1,"BSOC:LI04:07:EqpWarn_calc.INPB") #! Field("BSOC:LI04:07:EqpWarn_calc.OUT",16777215,1,"BSOC:LI04:07:EqpWarn_calc.OUT") #! Link("BSOC:LI04:07:EqpWarn_calc.OUT","BSOC:LI04:07:EqpWarn.VAL") #! Record("BSOC:LI04:07:EqpWarn",500,20,0,0,"BSOC:LI04:07:EqpWarn") #! Field("BSOC:LI04:07:EqpWarn.VAL",16777215,1,"BSOC:LI04:07:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi104") { field(DESC, "Port LI03_BSOIC_Rd bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 104, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI05:08:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi104Valid") { field(INPA, "PLC:LI03:PP01:Bi104.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:EqpWarn_calc") { field(INPA, "PLC:LI03:PP01:Bi104 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi104Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb104",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb104") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb104.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb104.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb104.FLNK","BSOC:LI05:08:EqpWarn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb104.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb104.VAL") #! Record("BSOC:LI05:08:EqpWarn_calc",260,18,0,1,"BSOC:LI05:08:EqpWarn_calc") #! Field("BSOC:LI05:08:EqpWarn_calc.INPA",16777215,0,"BSOC:LI05:08:EqpWarn_calc.INPA") #! Link("BSOC:LI05:08:EqpWarn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb104.VAL") #! Field("BSOC:LI05:08:EqpWarn_calc.INPB",16777215,1,"BSOC:LI05:08:EqpWarn_calc.INPB") #! Field("BSOC:LI05:08:EqpWarn_calc.OUT",16777215,1,"BSOC:LI05:08:EqpWarn_calc.OUT") #! Link("BSOC:LI05:08:EqpWarn_calc.OUT","BSOC:LI05:08:EqpWarn.VAL") #! Record("BSOC:LI05:08:EqpWarn",500,20,0,0,"BSOC:LI05:08:EqpWarn") #! Field("BSOC:LI05:08:EqpWarn.VAL",16777215,1,"BSOC:LI05:08:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi119") { field(DESC, "Port LI03_BSOIC_Rd bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 119, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI03:G4:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi119Valid") { field(INPA, "PLC:LI03:PP01:Bi119.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:EqpWarn_calc") { field(INPA, "PLC:LI03:PP01:Bi119 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi119Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb119",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb119") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb119.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb119.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb119.FLNK","BSOC:LI03:G4:EqpWarn_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb119.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb119.VAL") #! Record("BSOC:LI03:G4:EqpWarn_calc",260,18,0,1,"BSOC:LI03:G4:EqpWarn_calc") #! Field("BSOC:LI03:G4:EqpWarn_calc.INPA",16777215,0,"BSOC:LI03:G4:EqpWarn_calc.INPA") #! Link("BSOC:LI03:G4:EqpWarn_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb119.VAL") #! Field("BSOC:LI03:G4:EqpWarn_calc.INPB",16777215,1,"BSOC:LI03:G4:EqpWarn_calc.INPB") #! Field("BSOC:LI03:G4:EqpWarn_calc.OUT",16777215,1,"BSOC:LI03:G4:EqpWarn_calc.OUT") #! Link("BSOC:LI03:G4:EqpWarn_calc.OUT","BSOC:LI03:G4:EqpWarn.VAL") #! Record("BSOC:LI03:G4:EqpWarn",500,20,0,0,"BSOC:LI03:G4:EqpWarn") #! Field("BSOC:LI03:G4:EqpWarn.VAL",16777215,1,"BSOC:LI03:G4:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi117") { field(DESC, "Port LI03_BSOIC_Rd bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 117, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI03:1:PLCHB_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi117Valid") { field(INPA, "PLC:LI03:PP01:Bi117.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:1:PLCHB_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:1:PLCHB_calc") { field(INPA, "PLC:LI03:PP01:Bi117 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi117Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:1:PLCHB PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:1:PLCHB") { field(DESC, "BSOIC-PLC_Heartbeat") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb117",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb117") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb117.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb117.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb117.FLNK","BSOC:LI03:1:PLCHB_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb117.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb117.VAL") #! Record("BSOC:LI03:1:PLCHB_calc",260,18,0,1,"BSOC:LI03:1:PLCHB_calc") #! Field("BSOC:LI03:1:PLCHB_calc.INPA",16777215,0,"BSOC:LI03:1:PLCHB_calc.INPA") #! Link("BSOC:LI03:1:PLCHB_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb117.VAL") #! Field("BSOC:LI03:1:PLCHB_calc.INPB",16777215,1,"BSOC:LI03:1:PLCHB_calc.INPB") #! Field("BSOC:LI03:1:PLCHB_calc.OUT",16777215,1,"BSOC:LI03:1:PLCHB_calc.OUT") #! Link("BSOC:LI03:1:PLCHB_calc.OUT","BSOC:LI03:1:PLCHB.VAL") #! Record("BSOC:LI03:1:PLCHB",500,20,0,0,"BSOC:LI03:1:PLCHB") #! Field("BSOC:LI03:1:PLCHB.VAL",16777215,1,"BSOC:LI03:1:PLCHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi116") { field(DESC, "Port LI03_BSOIC_Rd bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 116, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:06:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi116Valid") { field(INPA, "PLC:LI03:PP01:Bi116.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:06:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:06:ChOk_calc") { field(INPA, "PLC:LI03:PP01:Bi116 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi116Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:06:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:06:ChOk") { field(DESC, "BSOIC-CH1_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb116",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb116") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb116.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb116.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb116.FLNK","BSOC:LI04:06:ChOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb116.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb116.VAL") #! Record("BSOC:LI04:06:ChOk_calc",260,18,0,1,"BSOC:LI04:06:ChOk_calc") #! Field("BSOC:LI04:06:ChOk_calc.INPA",16777215,0,"BSOC:LI04:06:ChOk_calc.INPA") #! Link("BSOC:LI04:06:ChOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb116.VAL") #! Field("BSOC:LI04:06:ChOk_calc.INPB",16777215,1,"BSOC:LI04:06:ChOk_calc.INPB") #! Field("BSOC:LI04:06:ChOk_calc.OUT",16777215,1,"BSOC:LI04:06:ChOk_calc.OUT") #! Link("BSOC:LI04:06:ChOk_calc.OUT","BSOC:LI04:06:ChOk.VAL") #! Record("BSOC:LI04:06:ChOk",500,20,0,0,"BSOC:LI04:06:ChOk") #! Field("BSOC:LI04:06:ChOk.VAL",16777215,1,"BSOC:LI04:06:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi115") { field(DESC, "Port LI03_BSOIC_Rd bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 115, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:07:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi115Valid") { field(INPA, "PLC:LI03:PP01:Bi115.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:07:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:07:ChOk_calc") { field(INPA, "PLC:LI03:PP01:Bi115 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi115Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:07:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:07:ChOk") { field(DESC, "BSOIC-CH2_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb115",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb115") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb115.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb115.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb115.FLNK","BSOC:LI04:07:ChOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb115.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb115.VAL") #! Record("BSOC:LI04:07:ChOk_calc",260,18,0,1,"BSOC:LI04:07:ChOk_calc") #! Field("BSOC:LI04:07:ChOk_calc.INPA",16777215,0,"BSOC:LI04:07:ChOk_calc.INPA") #! Link("BSOC:LI04:07:ChOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb115.VAL") #! Field("BSOC:LI04:07:ChOk_calc.INPB",16777215,1,"BSOC:LI04:07:ChOk_calc.INPB") #! Field("BSOC:LI04:07:ChOk_calc.OUT",16777215,1,"BSOC:LI04:07:ChOk_calc.OUT") #! Link("BSOC:LI04:07:ChOk_calc.OUT","BSOC:LI04:07:ChOk.VAL") #! Record("BSOC:LI04:07:ChOk",500,20,0,0,"BSOC:LI04:07:ChOk") #! Field("BSOC:LI04:07:ChOk.VAL",16777215,1,"BSOC:LI04:07:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi114") { field(DESC, "Port LI03_BSOIC_Rd bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 114, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:08:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi114Valid") { field(INPA, "PLC:LI03:PP01:Bi114.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:08:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:08:ChOk_calc") { field(INPA, "PLC:LI03:PP01:Bi114 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi114Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:08:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:08:ChOk") { field(DESC, "BSOIC-CH3_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb114",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb114") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb114.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb114.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb114.FLNK","BSOC:LI05:08:ChOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb114.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb114.VAL") #! Record("BSOC:LI05:08:ChOk_calc",260,18,0,1,"BSOC:LI05:08:ChOk_calc") #! Field("BSOC:LI05:08:ChOk_calc.INPA",16777215,0,"BSOC:LI05:08:ChOk_calc.INPA") #! Link("BSOC:LI05:08:ChOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb114.VAL") #! Field("BSOC:LI05:08:ChOk_calc.INPB",16777215,1,"BSOC:LI05:08:ChOk_calc.INPB") #! Field("BSOC:LI05:08:ChOk_calc.OUT",16777215,1,"BSOC:LI05:08:ChOk_calc.OUT") #! Link("BSOC:LI05:08:ChOk_calc.OUT","BSOC:LI05:08:ChOk.VAL") #! Record("BSOC:LI05:08:ChOk",500,20,0,0,"BSOC:LI05:08:ChOk") #! Field("BSOC:LI05:08:ChOk.VAL",16777215,1,"BSOC:LI05:08:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi113") { field(DESC, "Port LI03_BSOIC_Rd bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 113, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI03:G4:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi113Valid") { field(INPA, "PLC:LI03:PP01:Bi113.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI03:G4:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI03:G4:ChOk_calc") { field(INPA, "PLC:LI03:PP01:Bi113 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi113Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI03:G4:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI03:G4:ChOk") { field(DESC, "BSOIC-CH4_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb113",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb113") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb113.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb113.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb113.FLNK","BSOC:LI03:G4:ChOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb113.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb113.VAL") #! Record("BSOC:LI03:G4:ChOk_calc",260,18,0,1,"BSOC:LI03:G4:ChOk_calc") #! Field("BSOC:LI03:G4:ChOk_calc.INPA",16777215,0,"BSOC:LI03:G4:ChOk_calc.INPA") #! Link("BSOC:LI03:G4:ChOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb113.VAL") #! Field("BSOC:LI03:G4:ChOk_calc.INPB",16777215,1,"BSOC:LI03:G4:ChOk_calc.INPB") #! Field("BSOC:LI03:G4:ChOk_calc.OUT",16777215,1,"BSOC:LI03:G4:ChOk_calc.OUT") #! Link("BSOC:LI03:G4:ChOk_calc.OUT","BSOC:LI03:G4:ChOk.VAL") #! Record("BSOC:LI03:G4:ChOk",500,20,0,0,"BSOC:LI03:G4:ChOk") #! Field("BSOC:LI03:G4:ChOk.VAL",16777215,1,"BSOC:LI03:G4:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi112") { field(DESC, "Port LI03_BSOIC_Rd bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 112, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI04:14N:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi112Valid") { field(INPA, "PLC:LI03:PP01:Bi112.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI04:14N:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI04:14N:ChOk_calc") { field(INPA, "PLC:LI03:PP01:Bi112 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi112Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI04:14N:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI04:14N:ChOk") { field(DESC, "BSOIC-CH5_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb112",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb112") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb112.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb112.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb112.FLNK","BSOC:LI04:14N:ChOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb112.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb112.VAL") #! Record("BSOC:LI04:14N:ChOk_calc",260,18,0,1,"BSOC:LI04:14N:ChOk_calc") #! Field("BSOC:LI04:14N:ChOk_calc.INPA",16777215,0,"BSOC:LI04:14N:ChOk_calc.INPA") #! Link("BSOC:LI04:14N:ChOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb112.VAL") #! Field("BSOC:LI04:14N:ChOk_calc.INPB",16777215,1,"BSOC:LI04:14N:ChOk_calc.INPB") #! Field("BSOC:LI04:14N:ChOk_calc.OUT",16777215,1,"BSOC:LI04:14N:ChOk_calc.OUT") #! Link("BSOC:LI04:14N:ChOk_calc.OUT","BSOC:LI04:14N:ChOk.VAL") #! Record("BSOC:LI04:14N:ChOk",500,20,0,0,"BSOC:LI04:14N:ChOk") #! Field("BSOC:LI04:14N:ChOk.VAL",16777215,1,"BSOC:LI04:14N:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI03:PP01:Bi127") { field(DESC, "Port LI03_BSOIC_Rd bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 127, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI05:15N:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:Bi127Valid") { field(INPA, "PLC:LI03:PP01:Bi127.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI05:15N:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI05:15N:ChOk_calc") { field(INPA, "PLC:LI03:PP01:Bi127 NPP NMS") field(INPB, "PLC:LI03:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI03:PP01:Bi127Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI05:15N:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI05:15N:ChOk") { field(DESC, "BSOIC-CH6_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI03:PP01:LI03_BSOIC_Rdb127",20,19,0,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb127") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb127.FLNK",16777215,1,"PLC:LI03:PP01:LI03_BSOIC_Rdb127.FLNK") #! Link("PLC:LI03:PP01:LI03_BSOIC_Rdb127.FLNK","BSOC:LI05:15N:ChOk_calc") #! Field("PLC:LI03:PP01:LI03_BSOIC_Rdb127.VAL",16777215,0,"PLC:LI03:PP01:LI03_BSOIC_Rdb127.VAL") #! Record("BSOC:LI05:15N:ChOk_calc",260,18,0,1,"BSOC:LI05:15N:ChOk_calc") #! Field("BSOC:LI05:15N:ChOk_calc.INPA",16777215,0,"BSOC:LI05:15N:ChOk_calc.INPA") #! Link("BSOC:LI05:15N:ChOk_calc.INPA","PLC:LI03:PP01:LI03_BSOIC_Rdb127.VAL") #! Field("BSOC:LI05:15N:ChOk_calc.INPB",16777215,1,"BSOC:LI05:15N:ChOk_calc.INPB") #! Field("BSOC:LI05:15N:ChOk_calc.OUT",16777215,1,"BSOC:LI05:15N:ChOk_calc.OUT") #! Link("BSOC:LI05:15N:ChOk_calc.OUT","BSOC:LI05:15N:ChOk.VAL") #! Record("BSOC:LI05:15N:ChOk",500,20,0,0,"BSOC:LI05:15N:ChOk") #! Field("BSOC:LI05:15N:ChOk.VAL",16777215,1,"BSOC:LI05:15N:ChOk.VAL") record(bo, "BSOC:LI04:06:SReset") { field(DESC, "BSOIC-Soft_Reset_G1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI04:07:SReset") { field(DESC, "BSOIC-Soft_Reset_G2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI05:08:SReset") { field(DESC, "BSOIC-Soft_Reset_G3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 5, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI03:G4:SReset") { field(DESC, "BSOIC-Soft_Reset_G4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 4, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI04:14N:SReset") { field(DESC, "BSOIC-Soft_Reset_N1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI05:15N:SReset") { field(DESC, "BSOIC-Soft_Reset_N2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 2, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI03:1:SResetAll") { field(DESC, "BSOIC-Soft_Reset_All") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 1, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI03:1:SPauseHB") { field(DESC, "BSOIC-Soft_Pause_Hb") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Pause") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:LI03:PP01:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:LI03:PP01:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:LI03:PP01:TABLE_CYCLER") { field( OUT, "PLC:LI03:PP01:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:LI03:PP01:SEG_CYCLER") { field( OUT, "PLC:LI03:PP01:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:LI03:PP01:TABLE_9_SEG_1") { field( INPA, "PLC:LI03:PP01:REQ_TABLE CP") field( INPB, "PLC:LI03:PP01:REQ_SEG CP") field( INPC, "PLC:LI03:PP01:REQ_TABLE_IN CP") field( INPD, "PLC:LI03:PP01:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:LI03:PP01:TABLE_1_SEG_1") { field( INPA, "PLC:LI03:PP01:REQ_TABLE CP") field( INPB, "PLC:LI03:PP01:REQ_SEG CP") field( INPC, "PLC:LI03:PP01:REQ_TABLE_IN CP") field( INPD, "PLC:LI03:PP01:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI03:PP01:REQ_TABLE_OUT") { field(OUTA, "PLC:LI03:PP01:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:LI03:PP01:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:LI03:PP01:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:LI03:PP01:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:LI03:PP01:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:LI03:PP01:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:LI03:PP01:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:LI03:PP01:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:LI03:PP01:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT0 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT1 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT2 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT3 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT4 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT5 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT6 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:LI03:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI03:PP01:TABLE_BIT7 MS") field(INPC, "PLC:LI03:PP01:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI03:PP01:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:LI03:PP01:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:LI03:PP01:TABLE_BIT0 CP MS") field(INPB, "PLC:LI03:PP01:TABLE_BIT1 CP MS") field(INPC, "PLC:LI03:PP01:TABLE_BIT2 CP MS") field(INPD, "PLC:LI03:PP01:TABLE_BIT3 CP MS") field(INPE, "PLC:LI03:PP01:TABLE_BIT4 CP MS") field(INPF, "PLC:LI03:PP01:TABLE_BIT5 CP MS") field(INPG, "PLC:LI03:PP01:TABLE_BIT6 CP MS") field(INPH, "PLC:LI03:PP01:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI03:PP01:REQ_TABLE PP MS") #field(SDIS, "PLC:LI03:PP01:REQ_TABLE_OUT.PACT") } record(longout, "PLC:LI03:PP01:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:LI03:PP01:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI03:PP01:REQ_SEG_OUT") { field(OUTA, "PLC:LI03:PP01:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:LI03:PP01:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:LI03:PP01:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:LI03:PP01:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:LI03:PP01:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:LI03:PP01:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:LI03:PP01:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:LI03:PP01:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:LI03:PP01:REQ_SEG_IN.PACT") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT0 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT1 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT1 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT2 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT2 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT3 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT3 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT4 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT4 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT5 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT5 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT6 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT6 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:LI03:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI03:PP01:SEG_BIT7 MS") field(INPC, "PLC:LI03:PP01:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI03:PP01:REQ_SEG_BIT7 PP") } record(calcout, "PLC:LI03:PP01:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:LI03:PP01:SEG_BIT0 CP MS") field(INPB, "PLC:LI03:PP01:SEG_BIT1 CP MS") field(INPC, "PLC:LI03:PP01:SEG_BIT2 CP MS") field(INPD, "PLC:LI03:PP01:SEG_BIT3 CP MS") field(INPE, "PLC:LI03:PP01:SEG_BIT4 CP MS") field(INPF, "PLC:LI03:PP01:SEG_BIT5 CP MS") field(INPG, "PLC:LI03:PP01:SEG_BIT6 CP MS") field(INPH, "PLC:LI03:PP01:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI03:PP01:REQ_SEG PP MS") field(SDIS, "PLC:LI03:PP01:REQ_SEG_OUT.PACT") } record(bi, "PLC:LI03:PP01:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:PWLED") { field(DESC, "PLC-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:RUNLED") { field(DESC, "PLC-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:DIAGLED") { field(DESC, "PLC-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:FAULTLED") { field(DESC, "PLC-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:IFAULTLED") { field(DESC, "PLC-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:OFAULTLED") { field(DESC, "PLC-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI03:PP01:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Rd, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI03:PP01:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI03_BSOIC_Wrt, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:LI03:PP01:w0") { field(DESC, "Checksum word 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:w1") { field(DESC, "Checksum word 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 2, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:LI03:PP01:CHECKSUM_SDIS") { field(INPA, "PLC:LI03:PP01:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:LI03:PP01:w3") { field(DESC, "Checksum word 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 3, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:CHECKSUM_SAFE_calc") { field(INPA, "PLC:LI03:PP01:w3 PP MS") field(INPB, "PLC:LI03:PP01:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI03:PP01:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:LI03:PP01:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI03:PP01:w4") { field(DESC, "Checksum word 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 4, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:PROJ_CHECKSUM_calc") { field(INPA, "PLC:LI03:PP01:w4 NPP MS") field(INPB, "PLC:LI03:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI03:PP01:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI03:PP01:w5") { field(DESC, "Checksum word 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 5, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:DAY_MONTH_calc") { field(INPA, "PLC:LI03:PP01:w5 NPP MS") field(INPB, "PLC:LI03:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI03:PP01:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:LI03:PP01:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:LI03:PP01:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:LI03:PP01:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:LI03:PP01:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI03:PP01:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 6, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:PROJ_YEAR_calc") { field(INPA, "PLC:LI03:PP01:w6 NPP MS") field(INPB, "PLC:LI03:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI03:PP01:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI03:PP01:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 7, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:OP_HRS_MSB_calc") { field(INPA, "PLC:LI03:PP01:w7 NPP MS") field(INPB, "PLC:LI03:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI03:PP01:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI03_BSOIC_Wd, 8, 0xFFFF, 1)") field(FLNK, "PLC:LI03:PP01:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI03:PP01:OP_HRS_LSB_calc") { field(INPA, "PLC:LI03:PP01:w8 NPP MS") field(INPB, "PLC:LI03:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI03:PP01:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI03:PP01:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:LI03:PP01:OP_HOURS") { field(INPA, "PLC:LI03:PP01:OP_HRS_MSB CP MS") field(INPB, "PLC:LI03:PP01:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:LI03:PP01:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:LI03:PP01:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:LI03:PP01:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI03_BSOIC_Rd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI03:PP01:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI03:PP01:RDHist.PROC") } record(waveform,"PLC:LI03:PP01:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI03_BSOIC_Rd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI03:PP01:RDHistTimeAxis.PROC") } record(waveform,"PLC:LI03:PP01:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI03_BSOIC_Rd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI03:PP01:RDReadOK.PROC") } record(longout,"PLC:LI03:PP01:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI03_BSOIC_Rd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI03:PP01:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Rd 0)READ_OK") field(FLNK,"PLC:LI03:PP01:RDWriteOK.PROC") } record(longin,"PLC:LI03:PP01:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Rd 0)WRITE_OK") field(FLNK,"PLC:LI03:PP01:RDIOErrors.PROC") } record(longin,"PLC:LI03:PP01:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Rd 0)IO_ERRORS") field(FLNK,"PLC:LI03:PP01:RDLastIOTime.PROC") } record(longin,"PLC:LI03:PP01:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Rd 0)LAST_IO_TIME") field(FLNK,"PLC:LI03:PP01:RDMaxIOTime.PROC") } record(longin,"PLC:LI03:PP01:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Rd 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI03:PP01:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI03_BSOIC_Wrt 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI03:PP01:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI03:PP01:WRTHist.PROC") } record(waveform,"PLC:LI03:PP01:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI03_BSOIC_Wrt 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI03:PP01:WRTHistTimeAxis.PROC") } record(waveform,"PLC:LI03:PP01:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI03_BSOIC_Wrt 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI03:PP01:WRTReadOK.PROC") } record(longout,"PLC:LI03:PP01:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI03_BSOIC_Wrt 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI03:PP01:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wrt 0)READ_OK") field(FLNK,"PLC:LI03:PP01:WRTWriteOK.PROC") } record(longin,"PLC:LI03:PP01:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wrt 0)WRITE_OK") field(FLNK,"PLC:LI03:PP01:WRTIOErrors.PROC") } record(longin,"PLC:LI03:PP01:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wrt 0)IO_ERRORS") field(FLNK,"PLC:LI03:PP01:WRTLastIOTime.PROC") } record(longin,"PLC:LI03:PP01:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wrt 0)LAST_IO_TIME") field(FLNK,"PLC:LI03:PP01:WRTMaxIOTime.PROC") } record(longin,"PLC:LI03:PP01:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wrt 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI03:PP01:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI03_BSOIC_Wd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI03:PP01:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI03:PP01:WDHist.PROC") } record(waveform,"PLC:LI03:PP01:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI03_BSOIC_Wd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI03:PP01:WDHistTimeAxis.PROC") } record(waveform,"PLC:LI03:PP01:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI03_BSOIC_Wd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI03:PP01:WDReadOK.PROC") } record(longout,"PLC:LI03:PP01:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI03_BSOIC_Wd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI03:PP01:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wd 0)READ_OK") field(FLNK,"PLC:LI03:PP01:WDWriteOK.PROC") } record(longin,"PLC:LI03:PP01:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wd 0)WRITE_OK") field(FLNK,"PLC:LI03:PP01:WDIOErrors.PROC") } record(longin,"PLC:LI03:PP01:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wd 0)IO_ERRORS") field(FLNK,"PLC:LI03:PP01:WDLastIOTime.PROC") } record(longin,"PLC:LI03:PP01:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wd 0)LAST_IO_TIME") field(FLNK,"PLC:LI03:PP01:WDMaxIOTime.PROC") } record(longin,"PLC:LI03:PP01:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI03_BSOIC_Wd 0)MAX_IO_TIME") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi7") { field(DESC, "Port LI06_BSOIC_Rd bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BSOC:LI06:1:HwEn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi7Valid") { field(INPA, "PLC:LI06:PP01:Bi7.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:HwEn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:HwEn_calc") { field(INPA, "PLC:LI06:PP01:Bi7 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi7Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:HwEn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:HwEn") { field(DESC, "BSOIC-HW_Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb7",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb7") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb7.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb7.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb7.FLNK","BSOC:LI06:1:HwEn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb7.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb7.VAL") #! Record("BSOC:LI06:1:HwEn_calc",260,18,0,1,"BSOC:LI06:1:HwEn_calc") #! Field("BSOC:LI06:1:HwEn_calc.INPA",16777215,0,"BSOC:LI06:1:HwEn_calc.INPA") #! Link("BSOC:LI06:1:HwEn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb7.VAL") #! Field("BSOC:LI06:1:HwEn_calc.INPB",16777215,1,"BSOC:LI06:1:HwEn_calc.INPB") #! Field("BSOC:LI06:1:HwEn_calc.OUT",16777215,1,"BSOC:LI06:1:HwEn_calc.OUT") #! Link("BSOC:LI06:1:HwEn_calc.OUT","BSOC:LI06:1:HwEn.VAL") #! Record("BSOC:LI06:1:HwEn",500,20,0,0,"BSOC:LI06:1:HwEn") #! Field("BSOC:LI06:1:HwEn.VAL",16777215,1,"BSOC:LI06:1:HwEn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi6") { field(DESC, "Port LI06_BSOIC_Rd bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI06:1:HwResetAll_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi6Valid") { field(INPA, "PLC:LI06:PP01:Bi6.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:HwResetAll_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:HwResetAll_calc") { field(INPA, "PLC:LI06:PP01:Bi6 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi6Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:HwResetAll PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:HwResetAll") { field(DESC, "BSOIC-HW_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb6",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb6") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb6.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb6.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb6.FLNK","BSOC:LI06:1:HwResetAll_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb6.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb6.VAL") #! Record("BSOC:LI06:1:HwResetAll_calc",260,18,0,1,"BSOC:LI06:1:HwResetAll_calc") #! Field("BSOC:LI06:1:HwResetAll_calc.INPA",16777215,0,"BSOC:LI06:1:HwResetAll_calc.INPA") #! Link("BSOC:LI06:1:HwResetAll_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb6.VAL") #! Field("BSOC:LI06:1:HwResetAll_calc.INPB",16777215,1,"BSOC:LI06:1:HwResetAll_calc.INPB") #! Field("BSOC:LI06:1:HwResetAll_calc.OUT",16777215,1,"BSOC:LI06:1:HwResetAll_calc.OUT") #! Link("BSOC:LI06:1:HwResetAll_calc.OUT","BSOC:LI06:1:HwResetAll.VAL") #! Record("BSOC:LI06:1:HwResetAll",500,20,0,0,"BSOC:LI06:1:HwResetAll") #! Field("BSOC:LI06:1:HwResetAll.VAL",16777215,1,"BSOC:LI06:1:HwResetAll.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi5") { field(DESC, "Port LI06_BSOIC_Rd bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:09:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi5Valid") { field(INPA, "PLC:LI06:PP01:Bi5.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:Eqp_calc") { field(INPA, "PLC:LI06:PP01:Bi5 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi5Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:Eqp") { field(DESC, "BSOIC-RT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb5",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb5") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb5.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb5.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb5.FLNK","BSOC:LI07:09:Eqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb5.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb5.VAL") #! Record("BSOC:LI07:09:Eqp_calc",260,18,0,1,"BSOC:LI07:09:Eqp_calc") #! Field("BSOC:LI07:09:Eqp_calc.INPA",16777215,0,"BSOC:LI07:09:Eqp_calc.INPA") #! Link("BSOC:LI07:09:Eqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb5.VAL") #! Field("BSOC:LI07:09:Eqp_calc.INPB",16777215,1,"BSOC:LI07:09:Eqp_calc.INPB") #! Field("BSOC:LI07:09:Eqp_calc.OUT",16777215,1,"BSOC:LI07:09:Eqp_calc.OUT") #! Link("BSOC:LI07:09:Eqp_calc.OUT","BSOC:LI07:09:Eqp.VAL") #! Record("BSOC:LI07:09:Eqp",500,20,0,0,"BSOC:LI07:09:Eqp") #! Field("BSOC:LI07:09:Eqp.VAL",16777215,1,"BSOC:LI07:09:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi4") { field(DESC, "Port LI06_BSOIC_Rd bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 4, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:09:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi4Valid") { field(INPA, "PLC:LI06:PP01:Bi4.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:Rad_calc") { field(INPA, "PLC:LI06:PP01:Bi4 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi4Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:Rad") { field(DESC, "BSOIC-RT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb4",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb4") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb4.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb4.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb4.FLNK","BSOC:LI07:09:Rad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb4.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb4.VAL") #! Record("BSOC:LI07:09:Rad_calc",260,18,0,1,"BSOC:LI07:09:Rad_calc") #! Field("BSOC:LI07:09:Rad_calc.INPA",16777215,0,"BSOC:LI07:09:Rad_calc.INPA") #! Link("BSOC:LI07:09:Rad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb4.VAL") #! Field("BSOC:LI07:09:Rad_calc.INPB",16777215,1,"BSOC:LI07:09:Rad_calc.INPB") #! Field("BSOC:LI07:09:Rad_calc.OUT",16777215,1,"BSOC:LI07:09:Rad_calc.OUT") #! Link("BSOC:LI07:09:Rad_calc.OUT","BSOC:LI07:09:Rad.VAL") #! Record("BSOC:LI07:09:Rad",500,20,0,0,"BSOC:LI07:09:Rad") #! Field("BSOC:LI07:09:Rad.VAL",16777215,1,"BSOC:LI07:09:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi3") { field(DESC, "Port LI06_BSOIC_Rd bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI07:09:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi3Valid") { field(INPA, "PLC:LI06:PP01:Bi3.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:HWBypass_calc") { field(INPA, "PLC:LI06:PP01:Bi3 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi3Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:HWBypass") { field(DESC, "BSOIC-RT_G1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb3",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb3") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb3.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb3.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb3.FLNK","BSOC:LI07:09:HWBypass_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb3.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb3.VAL") #! Record("BSOC:LI07:09:HWBypass_calc",260,18,0,1,"BSOC:LI07:09:HWBypass_calc") #! Field("BSOC:LI07:09:HWBypass_calc.INPA",16777215,0,"BSOC:LI07:09:HWBypass_calc.INPA") #! Link("BSOC:LI07:09:HWBypass_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb3.VAL") #! Field("BSOC:LI07:09:HWBypass_calc.INPB",16777215,1,"BSOC:LI07:09:HWBypass_calc.INPB") #! Field("BSOC:LI07:09:HWBypass_calc.OUT",16777215,1,"BSOC:LI07:09:HWBypass_calc.OUT") #! Link("BSOC:LI07:09:HWBypass_calc.OUT","BSOC:LI07:09:HWBypass.VAL") #! Record("BSOC:LI07:09:HWBypass",500,20,0,0,"BSOC:LI07:09:HWBypass") #! Field("BSOC:LI07:09:HWBypass.VAL",16777215,1,"BSOC:LI07:09:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi2") { field(DESC, "Port LI06_BSOIC_Rd bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:10:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi2Valid") { field(INPA, "PLC:LI06:PP01:Bi2.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:Eqp_calc") { field(INPA, "PLC:LI06:PP01:Bi2 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi2Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:Eqp") { field(DESC, "BSOIC-RT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb2",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb2") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb2.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb2.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb2.FLNK","BSOC:LI07:10:Eqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb2.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb2.VAL") #! Record("BSOC:LI07:10:Eqp_calc",260,18,0,1,"BSOC:LI07:10:Eqp_calc") #! Field("BSOC:LI07:10:Eqp_calc.INPA",16777215,0,"BSOC:LI07:10:Eqp_calc.INPA") #! Link("BSOC:LI07:10:Eqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb2.VAL") #! Field("BSOC:LI07:10:Eqp_calc.INPB",16777215,1,"BSOC:LI07:10:Eqp_calc.INPB") #! Field("BSOC:LI07:10:Eqp_calc.OUT",16777215,1,"BSOC:LI07:10:Eqp_calc.OUT") #! Link("BSOC:LI07:10:Eqp_calc.OUT","BSOC:LI07:10:Eqp.VAL") #! Record("BSOC:LI07:10:Eqp",500,20,0,0,"BSOC:LI07:10:Eqp") #! Field("BSOC:LI07:10:Eqp.VAL",16777215,1,"BSOC:LI07:10:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi1") { field(DESC, "Port LI06_BSOIC_Rd bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:10:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi1Valid") { field(INPA, "PLC:LI06:PP01:Bi1.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:Rad_calc") { field(INPA, "PLC:LI06:PP01:Bi1 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi1Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:Rad") { field(DESC, "BSOIC-RT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb1",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb1") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb1.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb1.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb1.FLNK","BSOC:LI07:10:Rad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb1.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb1.VAL") #! Record("BSOC:LI07:10:Rad_calc",260,18,0,1,"BSOC:LI07:10:Rad_calc") #! Field("BSOC:LI07:10:Rad_calc.INPA",16777215,0,"BSOC:LI07:10:Rad_calc.INPA") #! Link("BSOC:LI07:10:Rad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb1.VAL") #! Field("BSOC:LI07:10:Rad_calc.INPB",16777215,1,"BSOC:LI07:10:Rad_calc.INPB") #! Field("BSOC:LI07:10:Rad_calc.OUT",16777215,1,"BSOC:LI07:10:Rad_calc.OUT") #! Link("BSOC:LI07:10:Rad_calc.OUT","BSOC:LI07:10:Rad.VAL") #! Record("BSOC:LI07:10:Rad",500,20,0,0,"BSOC:LI07:10:Rad") #! Field("BSOC:LI07:10:Rad.VAL",16777215,1,"BSOC:LI07:10:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi0") { field(DESC, "Port LI06_BSOIC_Rd bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI07:10:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi0Valid") { field(INPA, "PLC:LI06:PP01:Bi0.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:HWBypass_calc") { field(INPA, "PLC:LI06:PP01:Bi0 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi0Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:HWBypass") { field(DESC, "BSOIC-RT_G2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb0",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb0") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb0.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb0.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb0.FLNK","BSOC:LI07:10:HWBypass_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb0.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb0.VAL") #! Record("BSOC:LI07:10:HWBypass_calc",260,18,0,1,"BSOC:LI07:10:HWBypass_calc") #! Field("BSOC:LI07:10:HWBypass_calc.INPA",16777215,0,"BSOC:LI07:10:HWBypass_calc.INPA") #! Link("BSOC:LI07:10:HWBypass_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb0.VAL") #! Field("BSOC:LI07:10:HWBypass_calc.INPB",16777215,1,"BSOC:LI07:10:HWBypass_calc.INPB") #! Field("BSOC:LI07:10:HWBypass_calc.OUT",16777215,1,"BSOC:LI07:10:HWBypass_calc.OUT") #! Link("BSOC:LI07:10:HWBypass_calc.OUT","BSOC:LI07:10:HWBypass.VAL") #! Record("BSOC:LI07:10:HWBypass",500,20,0,0,"BSOC:LI07:10:HWBypass") #! Field("BSOC:LI07:10:HWBypass.VAL",16777215,1,"BSOC:LI07:10:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi15") { field(DESC, "Port LI06_BSOIC_Rd bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G3:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi15Valid") { field(INPA, "PLC:LI06:PP01:Bi15.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:Eqp_calc") { field(INPA, "PLC:LI06:PP01:Bi15 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi15Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:Eqp") { field(DESC, "BSOIC-RT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb15",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb15") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb15.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb15.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb15.FLNK","BSOC:LI06:G3:Eqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb15.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb15.VAL") #! Record("BSOC:LI06:G3:Eqp_calc",260,18,0,1,"BSOC:LI06:G3:Eqp_calc") #! Field("BSOC:LI06:G3:Eqp_calc.INPA",16777215,0,"BSOC:LI06:G3:Eqp_calc.INPA") #! Link("BSOC:LI06:G3:Eqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb15.VAL") #! Field("BSOC:LI06:G3:Eqp_calc.INPB",16777215,1,"BSOC:LI06:G3:Eqp_calc.INPB") #! Field("BSOC:LI06:G3:Eqp_calc.OUT",16777215,1,"BSOC:LI06:G3:Eqp_calc.OUT") #! Link("BSOC:LI06:G3:Eqp_calc.OUT","BSOC:LI06:G3:Eqp.VAL") #! Record("BSOC:LI06:G3:Eqp",500,20,0,0,"BSOC:LI06:G3:Eqp") #! Field("BSOC:LI06:G3:Eqp.VAL",16777215,1,"BSOC:LI06:G3:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi14") { field(DESC, "Port LI06_BSOIC_Rd bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G3:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi14Valid") { field(INPA, "PLC:LI06:PP01:Bi14.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:Rad_calc") { field(INPA, "PLC:LI06:PP01:Bi14 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi14Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:Rad") { field(DESC, "BSOIC-RT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb14",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb14") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb14.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb14.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb14.FLNK","BSOC:LI06:G3:Rad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb14.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb14.VAL") #! Record("BSOC:LI06:G3:Rad_calc",260,18,0,1,"BSOC:LI06:G3:Rad_calc") #! Field("BSOC:LI06:G3:Rad_calc.INPA",16777215,0,"BSOC:LI06:G3:Rad_calc.INPA") #! Link("BSOC:LI06:G3:Rad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb14.VAL") #! Field("BSOC:LI06:G3:Rad_calc.INPB",16777215,1,"BSOC:LI06:G3:Rad_calc.INPB") #! Field("BSOC:LI06:G3:Rad_calc.OUT",16777215,1,"BSOC:LI06:G3:Rad_calc.OUT") #! Link("BSOC:LI06:G3:Rad_calc.OUT","BSOC:LI06:G3:Rad.VAL") #! Record("BSOC:LI06:G3:Rad",500,20,0,0,"BSOC:LI06:G3:Rad") #! Field("BSOC:LI06:G3:Rad.VAL",16777215,1,"BSOC:LI06:G3:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi13") { field(DESC, "Port LI06_BSOIC_Rd bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 13, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI06:G3:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi13Valid") { field(INPA, "PLC:LI06:PP01:Bi13.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:HWBypass_calc") { field(INPA, "PLC:LI06:PP01:Bi13 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi13Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:HWBypass") { field(DESC, "BSOIC-RT_G3_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb13",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb13") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb13.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb13.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb13.FLNK","BSOC:LI06:G3:HWBypass_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb13.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb13.VAL") #! Record("BSOC:LI06:G3:HWBypass_calc",260,18,0,1,"BSOC:LI06:G3:HWBypass_calc") #! Field("BSOC:LI06:G3:HWBypass_calc.INPA",16777215,0,"BSOC:LI06:G3:HWBypass_calc.INPA") #! Link("BSOC:LI06:G3:HWBypass_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb13.VAL") #! Field("BSOC:LI06:G3:HWBypass_calc.INPB",16777215,1,"BSOC:LI06:G3:HWBypass_calc.INPB") #! Field("BSOC:LI06:G3:HWBypass_calc.OUT",16777215,1,"BSOC:LI06:G3:HWBypass_calc.OUT") #! Link("BSOC:LI06:G3:HWBypass_calc.OUT","BSOC:LI06:G3:HWBypass.VAL") #! Record("BSOC:LI06:G3:HWBypass",500,20,0,0,"BSOC:LI06:G3:HWBypass") #! Field("BSOC:LI06:G3:HWBypass.VAL",16777215,1,"BSOC:LI06:G3:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi12") { field(DESC, "Port LI06_BSOIC_Rd bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G4:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi12Valid") { field(INPA, "PLC:LI06:PP01:Bi12.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:Eqp_calc") { field(INPA, "PLC:LI06:PP01:Bi12 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi12Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:Eqp") { field(DESC, "BSOIC-RT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb12",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb12") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb12.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb12.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb12.FLNK","BSOC:LI06:G4:Eqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb12.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb12.VAL") #! Record("BSOC:LI06:G4:Eqp_calc",260,18,0,1,"BSOC:LI06:G4:Eqp_calc") #! Field("BSOC:LI06:G4:Eqp_calc.INPA",16777215,0,"BSOC:LI06:G4:Eqp_calc.INPA") #! Link("BSOC:LI06:G4:Eqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb12.VAL") #! Field("BSOC:LI06:G4:Eqp_calc.INPB",16777215,1,"BSOC:LI06:G4:Eqp_calc.INPB") #! Field("BSOC:LI06:G4:Eqp_calc.OUT",16777215,1,"BSOC:LI06:G4:Eqp_calc.OUT") #! Link("BSOC:LI06:G4:Eqp_calc.OUT","BSOC:LI06:G4:Eqp.VAL") #! Record("BSOC:LI06:G4:Eqp",500,20,0,0,"BSOC:LI06:G4:Eqp") #! Field("BSOC:LI06:G4:Eqp.VAL",16777215,1,"BSOC:LI06:G4:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi11") { field(DESC, "Port LI06_BSOIC_Rd bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G4:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi11Valid") { field(INPA, "PLC:LI06:PP01:Bi11.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:Rad_calc") { field(INPA, "PLC:LI06:PP01:Bi11 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi11Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:Rad") { field(DESC, "BSOIC-RT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb11",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb11") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb11.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb11.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb11.FLNK","BSOC:LI06:G4:Rad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb11.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb11.VAL") #! Record("BSOC:LI06:G4:Rad_calc",260,18,0,1,"BSOC:LI06:G4:Rad_calc") #! Field("BSOC:LI06:G4:Rad_calc.INPA",16777215,0,"BSOC:LI06:G4:Rad_calc.INPA") #! Link("BSOC:LI06:G4:Rad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb11.VAL") #! Field("BSOC:LI06:G4:Rad_calc.INPB",16777215,1,"BSOC:LI06:G4:Rad_calc.INPB") #! Field("BSOC:LI06:G4:Rad_calc.OUT",16777215,1,"BSOC:LI06:G4:Rad_calc.OUT") #! Link("BSOC:LI06:G4:Rad_calc.OUT","BSOC:LI06:G4:Rad.VAL") #! Record("BSOC:LI06:G4:Rad",500,20,0,0,"BSOC:LI06:G4:Rad") #! Field("BSOC:LI06:G4:Rad.VAL",16777215,1,"BSOC:LI06:G4:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi10") { field(DESC, "Port LI06_BSOIC_Rd bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 10, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI06:G4:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi10Valid") { field(INPA, "PLC:LI06:PP01:Bi10.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:HWBypass_calc") { field(INPA, "PLC:LI06:PP01:Bi10 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi10Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:HWBypass") { field(DESC, "BSOIC-RT_G4_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb10",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb10") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb10.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb10.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb10.FLNK","BSOC:LI06:G4:HWBypass_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb10.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb10.VAL") #! Record("BSOC:LI06:G4:HWBypass_calc",260,18,0,1,"BSOC:LI06:G4:HWBypass_calc") #! Field("BSOC:LI06:G4:HWBypass_calc.INPA",16777215,0,"BSOC:LI06:G4:HWBypass_calc.INPA") #! Link("BSOC:LI06:G4:HWBypass_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb10.VAL") #! Field("BSOC:LI06:G4:HWBypass_calc.INPB",16777215,1,"BSOC:LI06:G4:HWBypass_calc.INPB") #! Field("BSOC:LI06:G4:HWBypass_calc.OUT",16777215,1,"BSOC:LI06:G4:HWBypass_calc.OUT") #! Link("BSOC:LI06:G4:HWBypass_calc.OUT","BSOC:LI06:G4:HWBypass.VAL") #! Record("BSOC:LI06:G4:HWBypass",500,20,0,0,"BSOC:LI06:G4:HWBypass") #! Field("BSOC:LI06:G4:HWBypass.VAL",16777215,1,"BSOC:LI06:G4:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi9") { field(DESC, "Port LI06_BSOIC_Rd bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:11N:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi9Valid") { field(INPA, "PLC:LI06:PP01:Bi9.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:11N:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:11N:Rad_calc") { field(INPA, "PLC:LI06:PP01:Bi9 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi9Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:11N:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:11N:Rad") { field(DESC, "BSOIC-RT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb9",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb9") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb9.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb9.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb9.FLNK","BSOC:LI07:11N:Rad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb9.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb9.VAL") #! Record("BSOC:LI07:11N:Rad_calc",260,18,0,1,"BSOC:LI07:11N:Rad_calc") #! Field("BSOC:LI07:11N:Rad_calc.INPA",16777215,0,"BSOC:LI07:11N:Rad_calc.INPA") #! Link("BSOC:LI07:11N:Rad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb9.VAL") #! Field("BSOC:LI07:11N:Rad_calc.INPB",16777215,1,"BSOC:LI07:11N:Rad_calc.INPB") #! Field("BSOC:LI07:11N:Rad_calc.OUT",16777215,1,"BSOC:LI07:11N:Rad_calc.OUT") #! Link("BSOC:LI07:11N:Rad_calc.OUT","BSOC:LI07:11N:Rad.VAL") #! Record("BSOC:LI07:11N:Rad",500,20,0,0,"BSOC:LI07:11N:Rad") #! Field("BSOC:LI07:11N:Rad.VAL",16777215,1,"BSOC:LI07:11N:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi8") { field(DESC, "Port LI06_BSOIC_Rd bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 8, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI07:11N:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi8Valid") { field(INPA, "PLC:LI06:PP01:Bi8.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:11N:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:11N:HWBypass_calc") { field(INPA, "PLC:LI06:PP01:Bi8 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi8Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:11N:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:11N:HWBypass") { field(DESC, "BSOIC-RT_N1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb8",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb8") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb8.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb8.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb8.FLNK","BSOC:LI07:11N:HWBypass_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb8.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb8.VAL") #! Record("BSOC:LI07:11N:HWBypass_calc",260,18,0,1,"BSOC:LI07:11N:HWBypass_calc") #! Field("BSOC:LI07:11N:HWBypass_calc.INPA",16777215,0,"BSOC:LI07:11N:HWBypass_calc.INPA") #! Link("BSOC:LI07:11N:HWBypass_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb8.VAL") #! Field("BSOC:LI07:11N:HWBypass_calc.INPB",16777215,1,"BSOC:LI07:11N:HWBypass_calc.INPB") #! Field("BSOC:LI07:11N:HWBypass_calc.OUT",16777215,1,"BSOC:LI07:11N:HWBypass_calc.OUT") #! Link("BSOC:LI07:11N:HWBypass_calc.OUT","BSOC:LI07:11N:HWBypass.VAL") #! Record("BSOC:LI07:11N:HWBypass",500,20,0,0,"BSOC:LI07:11N:HWBypass") #! Field("BSOC:LI07:11N:HWBypass.VAL",16777215,1,"BSOC:LI07:11N:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi23") { field(DESC, "Port LI06_BSOIC_Rd bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:N2:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi23Valid") { field(INPA, "PLC:LI06:PP01:Bi23.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:N2:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:N2:Rad_calc") { field(INPA, "PLC:LI06:PP01:Bi23 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi23Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:N2:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:N2:Rad") { field(DESC, "BSOIC-RT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb23",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb23") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb23.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb23.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb23.FLNK","BSOC:LI06:N2:Rad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb23.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb23.VAL") #! Record("BSOC:LI06:N2:Rad_calc",260,18,0,1,"BSOC:LI06:N2:Rad_calc") #! Field("BSOC:LI06:N2:Rad_calc.INPA",16777215,0,"BSOC:LI06:N2:Rad_calc.INPA") #! Link("BSOC:LI06:N2:Rad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb23.VAL") #! Field("BSOC:LI06:N2:Rad_calc.INPB",16777215,1,"BSOC:LI06:N2:Rad_calc.INPB") #! Field("BSOC:LI06:N2:Rad_calc.OUT",16777215,1,"BSOC:LI06:N2:Rad_calc.OUT") #! Link("BSOC:LI06:N2:Rad_calc.OUT","BSOC:LI06:N2:Rad.VAL") #! Record("BSOC:LI06:N2:Rad",500,20,0,0,"BSOC:LI06:N2:Rad") #! Field("BSOC:LI06:N2:Rad.VAL",16777215,1,"BSOC:LI06:N2:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi22") { field(DESC, "Port LI06_BSOIC_Rd bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 22, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:LI06:N2:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi22Valid") { field(INPA, "PLC:LI06:PP01:Bi22.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:N2:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:N2:HWBypass_calc") { field(INPA, "PLC:LI06:PP01:Bi22 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi22Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:N2:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:N2:HWBypass") { field(DESC, "BSOIC-RT_N2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb22",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb22") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb22.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb22.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb22.FLNK","BSOC:LI06:N2:HWBypass_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb22.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb22.VAL") #! Record("BSOC:LI06:N2:HWBypass_calc",260,18,0,1,"BSOC:LI06:N2:HWBypass_calc") #! Field("BSOC:LI06:N2:HWBypass_calc.INPA",16777215,0,"BSOC:LI06:N2:HWBypass_calc.INPA") #! Link("BSOC:LI06:N2:HWBypass_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb22.VAL") #! Field("BSOC:LI06:N2:HWBypass_calc.INPB",16777215,1,"BSOC:LI06:N2:HWBypass_calc.INPB") #! Field("BSOC:LI06:N2:HWBypass_calc.OUT",16777215,1,"BSOC:LI06:N2:HWBypass_calc.OUT") #! Link("BSOC:LI06:N2:HWBypass_calc.OUT","BSOC:LI06:N2:HWBypass.VAL") #! Record("BSOC:LI06:N2:HWBypass",500,20,0,0,"BSOC:LI06:N2:HWBypass") #! Field("BSOC:LI06:N2:HWBypass.VAL",16777215,1,"BSOC:LI06:N2:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi21") { field(DESC, "Port LI06_BSOIC_Rd bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi21Valid") { field(INPA, "PLC:LI06:PP01:Bi21.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:CascIn_calc") { field(INPA, "PLC:LI06:PP01:Bi21 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi21Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb21",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb21") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb21.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb21.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb21.FLNK","BSOC:LI06:1:CascIn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb21.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb21.VAL") #! Record("BSOC:LI06:1:CascIn_calc",260,18,0,1,"BSOC:LI06:1:CascIn_calc") #! Field("BSOC:LI06:1:CascIn_calc.INPA",16777215,0,"BSOC:LI06:1:CascIn_calc.INPA") #! Link("BSOC:LI06:1:CascIn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb21.VAL") #! Field("BSOC:LI06:1:CascIn_calc.INPB",16777215,1,"BSOC:LI06:1:CascIn_calc.INPB") #! Field("BSOC:LI06:1:CascIn_calc.OUT",16777215,1,"BSOC:LI06:1:CascIn_calc.OUT") #! Link("BSOC:LI06:1:CascIn_calc.OUT","BSOC:LI06:1:CascIn.VAL") #! Record("BSOC:LI06:1:CascIn",500,20,0,0,"BSOC:LI06:1:CascIn") #! Field("BSOC:LI06:1:CascIn.VAL",16777215,1,"BSOC:LI06:1:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi20") { field(DESC, "Port LI06_BSOIC_Rd bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:2:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi20Valid") { field(INPA, "PLC:LI06:PP01:Bi20.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:2:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:2:CascIn_calc") { field(INPA, "PLC:LI06:PP01:Bi20 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi20Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:2:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:2:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb20",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb20") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb20.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb20.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb20.FLNK","BSOC:LI06:2:CascIn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb20.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb20.VAL") #! Record("BSOC:LI06:2:CascIn_calc",260,18,0,1,"BSOC:LI06:2:CascIn_calc") #! Field("BSOC:LI06:2:CascIn_calc.INPA",16777215,0,"BSOC:LI06:2:CascIn_calc.INPA") #! Link("BSOC:LI06:2:CascIn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb20.VAL") #! Field("BSOC:LI06:2:CascIn_calc.INPB",16777215,1,"BSOC:LI06:2:CascIn_calc.INPB") #! Field("BSOC:LI06:2:CascIn_calc.OUT",16777215,1,"BSOC:LI06:2:CascIn_calc.OUT") #! Link("BSOC:LI06:2:CascIn_calc.OUT","BSOC:LI06:2:CascIn.VAL") #! Record("BSOC:LI06:2:CascIn",500,20,0,0,"BSOC:LI06:2:CascIn") #! Field("BSOC:LI06:2:CascIn.VAL",16777215,1,"BSOC:LI06:2:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi19") { field(DESC, "Port LI06_BSOIC_Rd bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 19, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI07:09:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi19Valid") { field(INPA, "PLC:LI06:PP01:Bi19.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:SoRstRb_calc") { field(INPA, "PLC:LI06:PP01:Bi19 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi19Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:SoRstRb") { field(DESC, "BSOIC-G1_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb19",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb19") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb19.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb19.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb19.FLNK","BSOC:LI07:09:SoRstRb_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb19.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb19.VAL") #! Record("BSOC:LI07:09:SoRstRb_calc",260,18,0,1,"BSOC:LI07:09:SoRstRb_calc") #! Field("BSOC:LI07:09:SoRstRb_calc.INPA",16777215,0,"BSOC:LI07:09:SoRstRb_calc.INPA") #! Link("BSOC:LI07:09:SoRstRb_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb19.VAL") #! Field("BSOC:LI07:09:SoRstRb_calc.INPB",16777215,1,"BSOC:LI07:09:SoRstRb_calc.INPB") #! Field("BSOC:LI07:09:SoRstRb_calc.OUT",16777215,1,"BSOC:LI07:09:SoRstRb_calc.OUT") #! Link("BSOC:LI07:09:SoRstRb_calc.OUT","BSOC:LI07:09:SoRstRb.VAL") #! Record("BSOC:LI07:09:SoRstRb",500,20,0,0,"BSOC:LI07:09:SoRstRb") #! Field("BSOC:LI07:09:SoRstRb.VAL",16777215,1,"BSOC:LI07:09:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi18") { field(DESC, "Port LI06_BSOIC_Rd bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 18, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI07:10:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi18Valid") { field(INPA, "PLC:LI06:PP01:Bi18.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:SoRstRb_calc") { field(INPA, "PLC:LI06:PP01:Bi18 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi18Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:SoRstRb") { field(DESC, "BSOIC-G2_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb18",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb18") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb18.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb18.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb18.FLNK","BSOC:LI07:10:SoRstRb_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb18.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb18.VAL") #! Record("BSOC:LI07:10:SoRstRb_calc",260,18,0,1,"BSOC:LI07:10:SoRstRb_calc") #! Field("BSOC:LI07:10:SoRstRb_calc.INPA",16777215,0,"BSOC:LI07:10:SoRstRb_calc.INPA") #! Link("BSOC:LI07:10:SoRstRb_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb18.VAL") #! Field("BSOC:LI07:10:SoRstRb_calc.INPB",16777215,1,"BSOC:LI07:10:SoRstRb_calc.INPB") #! Field("BSOC:LI07:10:SoRstRb_calc.OUT",16777215,1,"BSOC:LI07:10:SoRstRb_calc.OUT") #! Link("BSOC:LI07:10:SoRstRb_calc.OUT","BSOC:LI07:10:SoRstRb.VAL") #! Record("BSOC:LI07:10:SoRstRb",500,20,0,0,"BSOC:LI07:10:SoRstRb") #! Field("BSOC:LI07:10:SoRstRb.VAL",16777215,1,"BSOC:LI07:10:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi17") { field(DESC, "Port LI06_BSOIC_Rd bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 17, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI06:G3:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi17Valid") { field(INPA, "PLC:LI06:PP01:Bi17.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:SoRstRb_calc") { field(INPA, "PLC:LI06:PP01:Bi17 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi17Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:SoRstRb") { field(DESC, "BSOIC-G3_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb17",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb17") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb17.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb17.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb17.FLNK","BSOC:LI06:G3:SoRstRb_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb17.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb17.VAL") #! Record("BSOC:LI06:G3:SoRstRb_calc",260,18,0,1,"BSOC:LI06:G3:SoRstRb_calc") #! Field("BSOC:LI06:G3:SoRstRb_calc.INPA",16777215,0,"BSOC:LI06:G3:SoRstRb_calc.INPA") #! Link("BSOC:LI06:G3:SoRstRb_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb17.VAL") #! Field("BSOC:LI06:G3:SoRstRb_calc.INPB",16777215,1,"BSOC:LI06:G3:SoRstRb_calc.INPB") #! Field("BSOC:LI06:G3:SoRstRb_calc.OUT",16777215,1,"BSOC:LI06:G3:SoRstRb_calc.OUT") #! Link("BSOC:LI06:G3:SoRstRb_calc.OUT","BSOC:LI06:G3:SoRstRb.VAL") #! Record("BSOC:LI06:G3:SoRstRb",500,20,0,0,"BSOC:LI06:G3:SoRstRb") #! Field("BSOC:LI06:G3:SoRstRb.VAL",16777215,1,"BSOC:LI06:G3:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi16") { field(DESC, "Port LI06_BSOIC_Rd bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 16, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:LI06:G4:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi16Valid") { field(INPA, "PLC:LI06:PP01:Bi16.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:SoRstRb_calc") { field(INPA, "PLC:LI06:PP01:Bi16 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi16Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:SoRstRb") { field(DESC, "BSOIC-G4_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb16",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb16") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb16.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb16.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb16.FLNK","BSOC:LI06:G4:SoRstRb_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb16.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb16.VAL") #! Record("BSOC:LI06:G4:SoRstRb_calc",260,18,0,1,"BSOC:LI06:G4:SoRstRb_calc") #! Field("BSOC:LI06:G4:SoRstRb_calc.INPA",16777215,0,"BSOC:LI06:G4:SoRstRb_calc.INPA") #! Link("BSOC:LI06:G4:SoRstRb_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb16.VAL") #! Field("BSOC:LI06:G4:SoRstRb_calc.INPB",16777215,1,"BSOC:LI06:G4:SoRstRb_calc.INPB") #! Field("BSOC:LI06:G4:SoRstRb_calc.OUT",16777215,1,"BSOC:LI06:G4:SoRstRb_calc.OUT") #! Link("BSOC:LI06:G4:SoRstRb_calc.OUT","BSOC:LI06:G4:SoRstRb.VAL") #! Record("BSOC:LI06:G4:SoRstRb",500,20,0,0,"BSOC:LI06:G4:SoRstRb") #! Field("BSOC:LI06:G4:SoRstRb.VAL",16777215,1,"BSOC:LI06:G4:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi95") { field(DESC, "Port LI06_BSOIC_Rd bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 95, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI06:1:AnnAlarm_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi95Valid") { field(INPA, "PLC:LI06:PP01:Bi95.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:AnnAlarm_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:AnnAlarm_calc") { field(INPA, "PLC:LI06:PP01:Bi95 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi95Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:AnnAlarm PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:AnnAlarm") { field(DESC, "BSOIC-HW_Annunciator_Alarm") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb95",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb95") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb95.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb95.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb95.FLNK","BSOC:LI06:1:AnnAlarm_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb95.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb95.VAL") #! Record("BSOC:LI06:1:AnnAlarm_calc",260,18,0,1,"BSOC:LI06:1:AnnAlarm_calc") #! Field("BSOC:LI06:1:AnnAlarm_calc.INPA",16777215,0,"BSOC:LI06:1:AnnAlarm_calc.INPA") #! Link("BSOC:LI06:1:AnnAlarm_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb95.VAL") #! Field("BSOC:LI06:1:AnnAlarm_calc.INPB",16777215,1,"BSOC:LI06:1:AnnAlarm_calc.INPB") #! Field("BSOC:LI06:1:AnnAlarm_calc.OUT",16777215,1,"BSOC:LI06:1:AnnAlarm_calc.OUT") #! Link("BSOC:LI06:1:AnnAlarm_calc.OUT","BSOC:LI06:1:AnnAlarm.VAL") #! Record("BSOC:LI06:1:AnnAlarm",500,20,0,0,"BSOC:LI06:1:AnnAlarm") #! Field("BSOC:LI06:1:AnnAlarm.VAL",16777215,1,"BSOC:LI06:1:AnnAlarm.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi94") { field(DESC, "Port LI06_BSOIC_Rd bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 94, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI06:1:CascOut_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi94Valid") { field(INPA, "PLC:LI06:PP01:Bi94.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:CascOut_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:CascOut_calc") { field(INPA, "PLC:LI06:PP01:Bi94 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi94Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:CascOut PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:CascOut") { field(DESC, "BSOIC-HW_Cascade_Out") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb94",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb94") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb94.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb94.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb94.FLNK","BSOC:LI06:1:CascOut_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb94.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb94.VAL") #! Record("BSOC:LI06:1:CascOut_calc",260,18,0,1,"BSOC:LI06:1:CascOut_calc") #! Field("BSOC:LI06:1:CascOut_calc.INPA",16777215,0,"BSOC:LI06:1:CascOut_calc.INPA") #! Link("BSOC:LI06:1:CascOut_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb94.VAL") #! Field("BSOC:LI06:1:CascOut_calc.INPB",16777215,1,"BSOC:LI06:1:CascOut_calc.INPB") #! Field("BSOC:LI06:1:CascOut_calc.OUT",16777215,1,"BSOC:LI06:1:CascOut_calc.OUT") #! Link("BSOC:LI06:1:CascOut_calc.OUT","BSOC:LI06:1:CascOut.VAL") #! Record("BSOC:LI06:1:CascOut",500,20,0,0,"BSOC:LI06:1:CascOut") #! Field("BSOC:LI06:1:CascOut.VAL",16777215,1,"BSOC:LI06:1:CascOut.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi93") { field(DESC, "Port LI06_BSOIC_Rd bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:HWSfOut1_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi93Valid") { field(INPA, "PLC:LI06:PP01:Bi93.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:HWSfOut1_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:HWSfOut1_calc") { field(INPA, "PLC:LI06:PP01:Bi93 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi93Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:HWSfOut1 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:HWSfOut1") { field(DESC, "BSOIC-HW_Safety_Out1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb93",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb93") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb93.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb93.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb93.FLNK","BSOC:LI06:1:HWSfOut1_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb93.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb93.VAL") #! Record("BSOC:LI06:1:HWSfOut1_calc",260,18,0,1,"BSOC:LI06:1:HWSfOut1_calc") #! Field("BSOC:LI06:1:HWSfOut1_calc.INPA",16777215,0,"BSOC:LI06:1:HWSfOut1_calc.INPA") #! Link("BSOC:LI06:1:HWSfOut1_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb93.VAL") #! Field("BSOC:LI06:1:HWSfOut1_calc.INPB",16777215,1,"BSOC:LI06:1:HWSfOut1_calc.INPB") #! Field("BSOC:LI06:1:HWSfOut1_calc.OUT",16777215,1,"BSOC:LI06:1:HWSfOut1_calc.OUT") #! Link("BSOC:LI06:1:HWSfOut1_calc.OUT","BSOC:LI06:1:HWSfOut1.VAL") #! Record("BSOC:LI06:1:HWSfOut1",500,20,0,0,"BSOC:LI06:1:HWSfOut1") #! Field("BSOC:LI06:1:HWSfOut1.VAL",16777215,1,"BSOC:LI06:1:HWSfOut1.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi92") { field(DESC, "Port LI06_BSOIC_Rd bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:HWSfOut2_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi92Valid") { field(INPA, "PLC:LI06:PP01:Bi92.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:HWSfOut2_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:HWSfOut2_calc") { field(INPA, "PLC:LI06:PP01:Bi92 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi92Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:HWSfOut2 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:HWSfOut2") { field(DESC, "BSOIC-HW_Safety_Out2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb92",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb92") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb92.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb92.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb92.FLNK","BSOC:LI06:1:HWSfOut2_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb92.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb92.VAL") #! Record("BSOC:LI06:1:HWSfOut2_calc",260,18,0,1,"BSOC:LI06:1:HWSfOut2_calc") #! Field("BSOC:LI06:1:HWSfOut2_calc.INPA",16777215,0,"BSOC:LI06:1:HWSfOut2_calc.INPA") #! Link("BSOC:LI06:1:HWSfOut2_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb92.VAL") #! Field("BSOC:LI06:1:HWSfOut2_calc.INPB",16777215,1,"BSOC:LI06:1:HWSfOut2_calc.INPB") #! Field("BSOC:LI06:1:HWSfOut2_calc.OUT",16777215,1,"BSOC:LI06:1:HWSfOut2_calc.OUT") #! Link("BSOC:LI06:1:HWSfOut2_calc.OUT","BSOC:LI06:1:HWSfOut2.VAL") #! Record("BSOC:LI06:1:HWSfOut2",500,20,0,0,"BSOC:LI06:1:HWSfOut2") #! Field("BSOC:LI06:1:HWSfOut2.VAL",16777215,1,"BSOC:LI06:1:HWSfOut2.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi91") { field(DESC, "Port LI06_BSOIC_Rd bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:HWSfOut3_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi91Valid") { field(INPA, "PLC:LI06:PP01:Bi91.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:HWSfOut3_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:HWSfOut3_calc") { field(INPA, "PLC:LI06:PP01:Bi91 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi91Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:HWSfOut3 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:HWSfOut3") { field(DESC, "BSOIC-HW_Safety_Out3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb91",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb91") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb91.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb91.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb91.FLNK","BSOC:LI06:1:HWSfOut3_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb91.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb91.VAL") #! Record("BSOC:LI06:1:HWSfOut3_calc",260,18,0,1,"BSOC:LI06:1:HWSfOut3_calc") #! Field("BSOC:LI06:1:HWSfOut3_calc.INPA",16777215,0,"BSOC:LI06:1:HWSfOut3_calc.INPA") #! Link("BSOC:LI06:1:HWSfOut3_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb91.VAL") #! Field("BSOC:LI06:1:HWSfOut3_calc.INPB",16777215,1,"BSOC:LI06:1:HWSfOut3_calc.INPB") #! Field("BSOC:LI06:1:HWSfOut3_calc.OUT",16777215,1,"BSOC:LI06:1:HWSfOut3_calc.OUT") #! Link("BSOC:LI06:1:HWSfOut3_calc.OUT","BSOC:LI06:1:HWSfOut3.VAL") #! Record("BSOC:LI06:1:HWSfOut3",500,20,0,0,"BSOC:LI06:1:HWSfOut3") #! Field("BSOC:LI06:1:HWSfOut3.VAL",16777215,1,"BSOC:LI06:1:HWSfOut3.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi90") { field(DESC, "Port LI06_BSOIC_Rd bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:HWSfOut4_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi90Valid") { field(INPA, "PLC:LI06:PP01:Bi90.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:HWSfOut4_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:HWSfOut4_calc") { field(INPA, "PLC:LI06:PP01:Bi90 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi90Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:HWSfOut4 PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:HWSfOut4") { field(DESC, "BSOIC-HW_Safety_Out4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb90",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb90") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb90.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb90.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb90.FLNK","BSOC:LI06:1:HWSfOut4_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb90.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb90.VAL") #! Record("BSOC:LI06:1:HWSfOut4_calc",260,18,0,1,"BSOC:LI06:1:HWSfOut4_calc") #! Field("BSOC:LI06:1:HWSfOut4_calc.INPA",16777215,0,"BSOC:LI06:1:HWSfOut4_calc.INPA") #! Link("BSOC:LI06:1:HWSfOut4_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb90.VAL") #! Field("BSOC:LI06:1:HWSfOut4_calc.INPB",16777215,1,"BSOC:LI06:1:HWSfOut4_calc.INPB") #! Field("BSOC:LI06:1:HWSfOut4_calc.OUT",16777215,1,"BSOC:LI06:1:HWSfOut4_calc.OUT") #! Link("BSOC:LI06:1:HWSfOut4_calc.OUT","BSOC:LI06:1:HWSfOut4.VAL") #! Record("BSOC:LI06:1:HWSfOut4",500,20,0,0,"BSOC:LI06:1:HWSfOut4") #! Field("BSOC:LI06:1:HWSfOut4.VAL",16777215,1,"BSOC:LI06:1:HWSfOut4.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi89") { field(DESC, "Port LI06_BSOIC_Rd bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:09:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi89Valid") { field(INPA, "PLC:LI06:PP01:Bi89.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:LatEqp_calc") { field(INPA, "PLC:LI06:PP01:Bi89 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi89Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:LatEqp") { field(DESC, "BSOIC-LAT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb89",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb89") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb89.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb89.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb89.FLNK","BSOC:LI07:09:LatEqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb89.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb89.VAL") #! Record("BSOC:LI07:09:LatEqp_calc",260,18,0,1,"BSOC:LI07:09:LatEqp_calc") #! Field("BSOC:LI07:09:LatEqp_calc.INPA",16777215,0,"BSOC:LI07:09:LatEqp_calc.INPA") #! Link("BSOC:LI07:09:LatEqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb89.VAL") #! Field("BSOC:LI07:09:LatEqp_calc.INPB",16777215,1,"BSOC:LI07:09:LatEqp_calc.INPB") #! Field("BSOC:LI07:09:LatEqp_calc.OUT",16777215,1,"BSOC:LI07:09:LatEqp_calc.OUT") #! Link("BSOC:LI07:09:LatEqp_calc.OUT","BSOC:LI07:09:LatEqp.VAL") #! Record("BSOC:LI07:09:LatEqp",500,20,0,0,"BSOC:LI07:09:LatEqp") #! Field("BSOC:LI07:09:LatEqp.VAL",16777215,1,"BSOC:LI07:09:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi88") { field(DESC, "Port LI06_BSOIC_Rd bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:09:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi88Valid") { field(INPA, "PLC:LI06:PP01:Bi88.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:LatRad_calc") { field(INPA, "PLC:LI06:PP01:Bi88 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi88Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:LatRad") { field(DESC, "BSOIC-LAT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb88",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb88") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb88.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb88.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb88.FLNK","BSOC:LI07:09:LatRad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb88.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb88.VAL") #! Record("BSOC:LI07:09:LatRad_calc",260,18,0,1,"BSOC:LI07:09:LatRad_calc") #! Field("BSOC:LI07:09:LatRad_calc.INPA",16777215,0,"BSOC:LI07:09:LatRad_calc.INPA") #! Link("BSOC:LI07:09:LatRad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb88.VAL") #! Field("BSOC:LI07:09:LatRad_calc.INPB",16777215,1,"BSOC:LI07:09:LatRad_calc.INPB") #! Field("BSOC:LI07:09:LatRad_calc.OUT",16777215,1,"BSOC:LI07:09:LatRad_calc.OUT") #! Link("BSOC:LI07:09:LatRad_calc.OUT","BSOC:LI07:09:LatRad.VAL") #! Record("BSOC:LI07:09:LatRad",500,20,0,0,"BSOC:LI07:09:LatRad") #! Field("BSOC:LI07:09:LatRad.VAL",16777215,1,"BSOC:LI07:09:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi103") { field(DESC, "Port LI06_BSOIC_Rd bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:10:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi103Valid") { field(INPA, "PLC:LI06:PP01:Bi103.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:LatEqp_calc") { field(INPA, "PLC:LI06:PP01:Bi103 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi103Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:LatEqp") { field(DESC, "BSOIC-LAT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb103",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb103") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb103.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb103.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb103.FLNK","BSOC:LI07:10:LatEqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb103.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb103.VAL") #! Record("BSOC:LI07:10:LatEqp_calc",260,18,0,1,"BSOC:LI07:10:LatEqp_calc") #! Field("BSOC:LI07:10:LatEqp_calc.INPA",16777215,0,"BSOC:LI07:10:LatEqp_calc.INPA") #! Link("BSOC:LI07:10:LatEqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb103.VAL") #! Field("BSOC:LI07:10:LatEqp_calc.INPB",16777215,1,"BSOC:LI07:10:LatEqp_calc.INPB") #! Field("BSOC:LI07:10:LatEqp_calc.OUT",16777215,1,"BSOC:LI07:10:LatEqp_calc.OUT") #! Link("BSOC:LI07:10:LatEqp_calc.OUT","BSOC:LI07:10:LatEqp.VAL") #! Record("BSOC:LI07:10:LatEqp",500,20,0,0,"BSOC:LI07:10:LatEqp") #! Field("BSOC:LI07:10:LatEqp.VAL",16777215,1,"BSOC:LI07:10:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi102") { field(DESC, "Port LI06_BSOIC_Rd bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:10:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi102Valid") { field(INPA, "PLC:LI06:PP01:Bi102.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:LatRad_calc") { field(INPA, "PLC:LI06:PP01:Bi102 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi102Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:LatRad") { field(DESC, "BSOIC-LAT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb102",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb102") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb102.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb102.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb102.FLNK","BSOC:LI07:10:LatRad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb102.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb102.VAL") #! Record("BSOC:LI07:10:LatRad_calc",260,18,0,1,"BSOC:LI07:10:LatRad_calc") #! Field("BSOC:LI07:10:LatRad_calc.INPA",16777215,0,"BSOC:LI07:10:LatRad_calc.INPA") #! Link("BSOC:LI07:10:LatRad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb102.VAL") #! Field("BSOC:LI07:10:LatRad_calc.INPB",16777215,1,"BSOC:LI07:10:LatRad_calc.INPB") #! Field("BSOC:LI07:10:LatRad_calc.OUT",16777215,1,"BSOC:LI07:10:LatRad_calc.OUT") #! Link("BSOC:LI07:10:LatRad_calc.OUT","BSOC:LI07:10:LatRad.VAL") #! Record("BSOC:LI07:10:LatRad",500,20,0,0,"BSOC:LI07:10:LatRad") #! Field("BSOC:LI07:10:LatRad.VAL",16777215,1,"BSOC:LI07:10:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi101") { field(DESC, "Port LI06_BSOIC_Rd bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G3:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi101Valid") { field(INPA, "PLC:LI06:PP01:Bi101.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:LatEqp_calc") { field(INPA, "PLC:LI06:PP01:Bi101 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi101Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:LatEqp") { field(DESC, "BSOIC-LAT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb101",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb101") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb101.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb101.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb101.FLNK","BSOC:LI06:G3:LatEqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb101.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb101.VAL") #! Record("BSOC:LI06:G3:LatEqp_calc",260,18,0,1,"BSOC:LI06:G3:LatEqp_calc") #! Field("BSOC:LI06:G3:LatEqp_calc.INPA",16777215,0,"BSOC:LI06:G3:LatEqp_calc.INPA") #! Link("BSOC:LI06:G3:LatEqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb101.VAL") #! Field("BSOC:LI06:G3:LatEqp_calc.INPB",16777215,1,"BSOC:LI06:G3:LatEqp_calc.INPB") #! Field("BSOC:LI06:G3:LatEqp_calc.OUT",16777215,1,"BSOC:LI06:G3:LatEqp_calc.OUT") #! Link("BSOC:LI06:G3:LatEqp_calc.OUT","BSOC:LI06:G3:LatEqp.VAL") #! Record("BSOC:LI06:G3:LatEqp",500,20,0,0,"BSOC:LI06:G3:LatEqp") #! Field("BSOC:LI06:G3:LatEqp.VAL",16777215,1,"BSOC:LI06:G3:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi100") { field(DESC, "Port LI06_BSOIC_Rd bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G3:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi100Valid") { field(INPA, "PLC:LI06:PP01:Bi100.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:LatRad_calc") { field(INPA, "PLC:LI06:PP01:Bi100 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi100Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:LatRad") { field(DESC, "BSOIC-LAT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb100",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb100") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb100.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb100.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb100.FLNK","BSOC:LI06:G3:LatRad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb100.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb100.VAL") #! Record("BSOC:LI06:G3:LatRad_calc",260,18,0,1,"BSOC:LI06:G3:LatRad_calc") #! Field("BSOC:LI06:G3:LatRad_calc.INPA",16777215,0,"BSOC:LI06:G3:LatRad_calc.INPA") #! Link("BSOC:LI06:G3:LatRad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb100.VAL") #! Field("BSOC:LI06:G3:LatRad_calc.INPB",16777215,1,"BSOC:LI06:G3:LatRad_calc.INPB") #! Field("BSOC:LI06:G3:LatRad_calc.OUT",16777215,1,"BSOC:LI06:G3:LatRad_calc.OUT") #! Link("BSOC:LI06:G3:LatRad_calc.OUT","BSOC:LI06:G3:LatRad.VAL") #! Record("BSOC:LI06:G3:LatRad",500,20,0,0,"BSOC:LI06:G3:LatRad") #! Field("BSOC:LI06:G3:LatRad.VAL",16777215,1,"BSOC:LI06:G3:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi99") { field(DESC, "Port LI06_BSOIC_Rd bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G4:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi99Valid") { field(INPA, "PLC:LI06:PP01:Bi99.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:LatEqp_calc") { field(INPA, "PLC:LI06:PP01:Bi99 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi99Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:LatEqp") { field(DESC, "BSOIC-LAT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb99",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb99") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb99.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb99.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb99.FLNK","BSOC:LI06:G4:LatEqp_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb99.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb99.VAL") #! Record("BSOC:LI06:G4:LatEqp_calc",260,18,0,1,"BSOC:LI06:G4:LatEqp_calc") #! Field("BSOC:LI06:G4:LatEqp_calc.INPA",16777215,0,"BSOC:LI06:G4:LatEqp_calc.INPA") #! Link("BSOC:LI06:G4:LatEqp_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb99.VAL") #! Field("BSOC:LI06:G4:LatEqp_calc.INPB",16777215,1,"BSOC:LI06:G4:LatEqp_calc.INPB") #! Field("BSOC:LI06:G4:LatEqp_calc.OUT",16777215,1,"BSOC:LI06:G4:LatEqp_calc.OUT") #! Link("BSOC:LI06:G4:LatEqp_calc.OUT","BSOC:LI06:G4:LatEqp.VAL") #! Record("BSOC:LI06:G4:LatEqp",500,20,0,0,"BSOC:LI06:G4:LatEqp") #! Field("BSOC:LI06:G4:LatEqp.VAL",16777215,1,"BSOC:LI06:G4:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi98") { field(DESC, "Port LI06_BSOIC_Rd bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G4:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi98Valid") { field(INPA, "PLC:LI06:PP01:Bi98.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:LatRad_calc") { field(INPA, "PLC:LI06:PP01:Bi98 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi98Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:LatRad") { field(DESC, "BSOIC-LAT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb98",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb98") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb98.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb98.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb98.FLNK","BSOC:LI06:G4:LatRad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb98.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb98.VAL") #! Record("BSOC:LI06:G4:LatRad_calc",260,18,0,1,"BSOC:LI06:G4:LatRad_calc") #! Field("BSOC:LI06:G4:LatRad_calc.INPA",16777215,0,"BSOC:LI06:G4:LatRad_calc.INPA") #! Link("BSOC:LI06:G4:LatRad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb98.VAL") #! Field("BSOC:LI06:G4:LatRad_calc.INPB",16777215,1,"BSOC:LI06:G4:LatRad_calc.INPB") #! Field("BSOC:LI06:G4:LatRad_calc.OUT",16777215,1,"BSOC:LI06:G4:LatRad_calc.OUT") #! Link("BSOC:LI06:G4:LatRad_calc.OUT","BSOC:LI06:G4:LatRad.VAL") #! Record("BSOC:LI06:G4:LatRad",500,20,0,0,"BSOC:LI06:G4:LatRad") #! Field("BSOC:LI06:G4:LatRad.VAL",16777215,1,"BSOC:LI06:G4:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi97") { field(DESC, "Port LI06_BSOIC_Rd bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:11N:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi97Valid") { field(INPA, "PLC:LI06:PP01:Bi97.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:11N:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:11N:LatRad_calc") { field(INPA, "PLC:LI06:PP01:Bi97 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi97Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:11N:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:11N:LatRad") { field(DESC, "BSOIC-LAT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb97",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb97") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb97.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb97.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb97.FLNK","BSOC:LI07:11N:LatRad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb97.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb97.VAL") #! Record("BSOC:LI07:11N:LatRad_calc",260,18,0,1,"BSOC:LI07:11N:LatRad_calc") #! Field("BSOC:LI07:11N:LatRad_calc.INPA",16777215,0,"BSOC:LI07:11N:LatRad_calc.INPA") #! Link("BSOC:LI07:11N:LatRad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb97.VAL") #! Field("BSOC:LI07:11N:LatRad_calc.INPB",16777215,1,"BSOC:LI07:11N:LatRad_calc.INPB") #! Field("BSOC:LI07:11N:LatRad_calc.OUT",16777215,1,"BSOC:LI07:11N:LatRad_calc.OUT") #! Link("BSOC:LI07:11N:LatRad_calc.OUT","BSOC:LI07:11N:LatRad.VAL") #! Record("BSOC:LI07:11N:LatRad",500,20,0,0,"BSOC:LI07:11N:LatRad") #! Field("BSOC:LI07:11N:LatRad.VAL",16777215,1,"BSOC:LI07:11N:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi96") { field(DESC, "Port LI06_BSOIC_Rd bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:N2:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi96Valid") { field(INPA, "PLC:LI06:PP01:Bi96.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:N2:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:N2:LatRad_calc") { field(INPA, "PLC:LI06:PP01:Bi96 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi96Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:N2:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:N2:LatRad") { field(DESC, "BSOIC-LAT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb96",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb96") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb96.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb96.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb96.FLNK","BSOC:LI06:N2:LatRad_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb96.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb96.VAL") #! Record("BSOC:LI06:N2:LatRad_calc",260,18,0,1,"BSOC:LI06:N2:LatRad_calc") #! Field("BSOC:LI06:N2:LatRad_calc.INPA",16777215,0,"BSOC:LI06:N2:LatRad_calc.INPA") #! Link("BSOC:LI06:N2:LatRad_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb96.VAL") #! Field("BSOC:LI06:N2:LatRad_calc.INPB",16777215,1,"BSOC:LI06:N2:LatRad_calc.INPB") #! Field("BSOC:LI06:N2:LatRad_calc.OUT",16777215,1,"BSOC:LI06:N2:LatRad_calc.OUT") #! Link("BSOC:LI06:N2:LatRad_calc.OUT","BSOC:LI06:N2:LatRad.VAL") #! Record("BSOC:LI06:N2:LatRad",500,20,0,0,"BSOC:LI06:N2:LatRad") #! Field("BSOC:LI06:N2:LatRad.VAL",16777215,1,"BSOC:LI06:N2:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi111") { field(DESC, "Port LI06_BSOIC_Rd bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi111Valid") { field(INPA, "PLC:LI06:PP01:Bi111.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:LatCascIn_calc") { field(INPA, "PLC:LI06:PP01:Bi111 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi111Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb111",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb111") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb111.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb111.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb111.FLNK","BSOC:LI06:1:LatCascIn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb111.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb111.VAL") #! Record("BSOC:LI06:1:LatCascIn_calc",260,18,0,1,"BSOC:LI06:1:LatCascIn_calc") #! Field("BSOC:LI06:1:LatCascIn_calc.INPA",16777215,0,"BSOC:LI06:1:LatCascIn_calc.INPA") #! Link("BSOC:LI06:1:LatCascIn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb111.VAL") #! Field("BSOC:LI06:1:LatCascIn_calc.INPB",16777215,1,"BSOC:LI06:1:LatCascIn_calc.INPB") #! Field("BSOC:LI06:1:LatCascIn_calc.OUT",16777215,1,"BSOC:LI06:1:LatCascIn_calc.OUT") #! Link("BSOC:LI06:1:LatCascIn_calc.OUT","BSOC:LI06:1:LatCascIn.VAL") #! Record("BSOC:LI06:1:LatCascIn",500,20,0,0,"BSOC:LI06:1:LatCascIn") #! Field("BSOC:LI06:1:LatCascIn.VAL",16777215,1,"BSOC:LI06:1:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi110") { field(DESC, "Port LI06_BSOIC_Rd bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:2:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi110Valid") { field(INPA, "PLC:LI06:PP01:Bi110.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:2:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:2:LatCascIn_calc") { field(INPA, "PLC:LI06:PP01:Bi110 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi110Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:2:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:2:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb110",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb110") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb110.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb110.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb110.FLNK","BSOC:LI06:2:LatCascIn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb110.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb110.VAL") #! Record("BSOC:LI06:2:LatCascIn_calc",260,18,0,1,"BSOC:LI06:2:LatCascIn_calc") #! Field("BSOC:LI06:2:LatCascIn_calc.INPA",16777215,0,"BSOC:LI06:2:LatCascIn_calc.INPA") #! Link("BSOC:LI06:2:LatCascIn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb110.VAL") #! Field("BSOC:LI06:2:LatCascIn_calc.INPB",16777215,1,"BSOC:LI06:2:LatCascIn_calc.INPB") #! Field("BSOC:LI06:2:LatCascIn_calc.OUT",16777215,1,"BSOC:LI06:2:LatCascIn_calc.OUT") #! Link("BSOC:LI06:2:LatCascIn_calc.OUT","BSOC:LI06:2:LatCascIn.VAL") #! Record("BSOC:LI06:2:LatCascIn",500,20,0,0,"BSOC:LI06:2:LatCascIn") #! Field("BSOC:LI06:2:LatCascIn.VAL",16777215,1,"BSOC:LI06:2:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi109") { field(DESC, "Port LI06_BSOIC_Rd bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:AllGOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi109Valid") { field(INPA, "PLC:LI06:PP01:Bi109.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:AllGOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:AllGOk_calc") { field(INPA, "PLC:LI06:PP01:Bi109 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi109Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:AllGOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:AllGOk") { field(DESC, "BSOIC-All_Gamma_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb109",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb109") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb109.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb109.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb109.FLNK","BSOC:LI06:1:AllGOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb109.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb109.VAL") #! Record("BSOC:LI06:1:AllGOk_calc",260,18,0,1,"BSOC:LI06:1:AllGOk_calc") #! Field("BSOC:LI06:1:AllGOk_calc.INPA",16777215,0,"BSOC:LI06:1:AllGOk_calc.INPA") #! Link("BSOC:LI06:1:AllGOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb109.VAL") #! Field("BSOC:LI06:1:AllGOk_calc.INPB",16777215,1,"BSOC:LI06:1:AllGOk_calc.INPB") #! Field("BSOC:LI06:1:AllGOk_calc.OUT",16777215,1,"BSOC:LI06:1:AllGOk_calc.OUT") #! Link("BSOC:LI06:1:AllGOk_calc.OUT","BSOC:LI06:1:AllGOk.VAL") #! Record("BSOC:LI06:1:AllGOk",500,20,0,0,"BSOC:LI06:1:AllGOk") #! Field("BSOC:LI06:1:AllGOk.VAL",16777215,1,"BSOC:LI06:1:AllGOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi108") { field(DESC, "Port LI06_BSOIC_Rd bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 108, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:AllNOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi108Valid") { field(INPA, "PLC:LI06:PP01:Bi108.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:AllNOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:AllNOk_calc") { field(INPA, "PLC:LI06:PP01:Bi108 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi108Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:AllNOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:AllNOk") { field(DESC, "BSOIC-All_Neutron_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb108",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb108") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb108.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb108.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb108.FLNK","BSOC:LI06:1:AllNOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb108.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb108.VAL") #! Record("BSOC:LI06:1:AllNOk_calc",260,18,0,1,"BSOC:LI06:1:AllNOk_calc") #! Field("BSOC:LI06:1:AllNOk_calc.INPA",16777215,0,"BSOC:LI06:1:AllNOk_calc.INPA") #! Link("BSOC:LI06:1:AllNOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb108.VAL") #! Field("BSOC:LI06:1:AllNOk_calc.INPB",16777215,1,"BSOC:LI06:1:AllNOk_calc.INPB") #! Field("BSOC:LI06:1:AllNOk_calc.OUT",16777215,1,"BSOC:LI06:1:AllNOk_calc.OUT") #! Link("BSOC:LI06:1:AllNOk_calc.OUT","BSOC:LI06:1:AllNOk.VAL") #! Record("BSOC:LI06:1:AllNOk",500,20,0,0,"BSOC:LI06:1:AllNOk") #! Field("BSOC:LI06:1:AllNOk.VAL",16777215,1,"BSOC:LI06:1:AllNOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi107") { field(DESC, "Port LI06_BSOIC_Rd bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:1:AllOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi107Valid") { field(INPA, "PLC:LI06:PP01:Bi107.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:AllOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:AllOk_calc") { field(INPA, "PLC:LI06:PP01:Bi107 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi107Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:AllOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:AllOk") { field(DESC, "BSOIC-All_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb107",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb107") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb107.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb107.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb107.FLNK","BSOC:LI06:1:AllOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb107.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb107.VAL") #! Record("BSOC:LI06:1:AllOk_calc",260,18,0,1,"BSOC:LI06:1:AllOk_calc") #! Field("BSOC:LI06:1:AllOk_calc.INPA",16777215,0,"BSOC:LI06:1:AllOk_calc.INPA") #! Link("BSOC:LI06:1:AllOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb107.VAL") #! Field("BSOC:LI06:1:AllOk_calc.INPB",16777215,1,"BSOC:LI06:1:AllOk_calc.INPB") #! Field("BSOC:LI06:1:AllOk_calc.OUT",16777215,1,"BSOC:LI06:1:AllOk_calc.OUT") #! Link("BSOC:LI06:1:AllOk_calc.OUT","BSOC:LI06:1:AllOk.VAL") #! Record("BSOC:LI06:1:AllOk",500,20,0,0,"BSOC:LI06:1:AllOk") #! Field("BSOC:LI06:1:AllOk.VAL",16777215,1,"BSOC:LI06:1:AllOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi106") { field(DESC, "Port LI06_BSOIC_Rd bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 106, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI07:09:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi106Valid") { field(INPA, "PLC:LI06:PP01:Bi106.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:EqpWarn_calc") { field(INPA, "PLC:LI06:PP01:Bi106 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi106Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb106",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb106") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb106.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb106.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb106.FLNK","BSOC:LI07:09:EqpWarn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb106.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb106.VAL") #! Record("BSOC:LI07:09:EqpWarn_calc",260,18,0,1,"BSOC:LI07:09:EqpWarn_calc") #! Field("BSOC:LI07:09:EqpWarn_calc.INPA",16777215,0,"BSOC:LI07:09:EqpWarn_calc.INPA") #! Link("BSOC:LI07:09:EqpWarn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb106.VAL") #! Field("BSOC:LI07:09:EqpWarn_calc.INPB",16777215,1,"BSOC:LI07:09:EqpWarn_calc.INPB") #! Field("BSOC:LI07:09:EqpWarn_calc.OUT",16777215,1,"BSOC:LI07:09:EqpWarn_calc.OUT") #! Link("BSOC:LI07:09:EqpWarn_calc.OUT","BSOC:LI07:09:EqpWarn.VAL") #! Record("BSOC:LI07:09:EqpWarn",500,20,0,0,"BSOC:LI07:09:EqpWarn") #! Field("BSOC:LI07:09:EqpWarn.VAL",16777215,1,"BSOC:LI07:09:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi105") { field(DESC, "Port LI06_BSOIC_Rd bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 105, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI07:10:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi105Valid") { field(INPA, "PLC:LI06:PP01:Bi105.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:EqpWarn_calc") { field(INPA, "PLC:LI06:PP01:Bi105 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi105Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb105",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb105") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb105.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb105.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb105.FLNK","BSOC:LI07:10:EqpWarn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb105.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb105.VAL") #! Record("BSOC:LI07:10:EqpWarn_calc",260,18,0,1,"BSOC:LI07:10:EqpWarn_calc") #! Field("BSOC:LI07:10:EqpWarn_calc.INPA",16777215,0,"BSOC:LI07:10:EqpWarn_calc.INPA") #! Link("BSOC:LI07:10:EqpWarn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb105.VAL") #! Field("BSOC:LI07:10:EqpWarn_calc.INPB",16777215,1,"BSOC:LI07:10:EqpWarn_calc.INPB") #! Field("BSOC:LI07:10:EqpWarn_calc.OUT",16777215,1,"BSOC:LI07:10:EqpWarn_calc.OUT") #! Link("BSOC:LI07:10:EqpWarn_calc.OUT","BSOC:LI07:10:EqpWarn.VAL") #! Record("BSOC:LI07:10:EqpWarn",500,20,0,0,"BSOC:LI07:10:EqpWarn") #! Field("BSOC:LI07:10:EqpWarn.VAL",16777215,1,"BSOC:LI07:10:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi104") { field(DESC, "Port LI06_BSOIC_Rd bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 104, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI06:G3:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi104Valid") { field(INPA, "PLC:LI06:PP01:Bi104.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:EqpWarn_calc") { field(INPA, "PLC:LI06:PP01:Bi104 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi104Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb104",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb104") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb104.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb104.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb104.FLNK","BSOC:LI06:G3:EqpWarn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb104.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb104.VAL") #! Record("BSOC:LI06:G3:EqpWarn_calc",260,18,0,1,"BSOC:LI06:G3:EqpWarn_calc") #! Field("BSOC:LI06:G3:EqpWarn_calc.INPA",16777215,0,"BSOC:LI06:G3:EqpWarn_calc.INPA") #! Link("BSOC:LI06:G3:EqpWarn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb104.VAL") #! Field("BSOC:LI06:G3:EqpWarn_calc.INPB",16777215,1,"BSOC:LI06:G3:EqpWarn_calc.INPB") #! Field("BSOC:LI06:G3:EqpWarn_calc.OUT",16777215,1,"BSOC:LI06:G3:EqpWarn_calc.OUT") #! Link("BSOC:LI06:G3:EqpWarn_calc.OUT","BSOC:LI06:G3:EqpWarn.VAL") #! Record("BSOC:LI06:G3:EqpWarn",500,20,0,0,"BSOC:LI06:G3:EqpWarn") #! Field("BSOC:LI06:G3:EqpWarn.VAL",16777215,1,"BSOC:LI06:G3:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi119") { field(DESC, "Port LI06_BSOIC_Rd bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 119, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:LI06:G4:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi119Valid") { field(INPA, "PLC:LI06:PP01:Bi119.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:EqpWarn_calc") { field(INPA, "PLC:LI06:PP01:Bi119 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi119Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb119",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb119") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb119.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb119.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb119.FLNK","BSOC:LI06:G4:EqpWarn_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb119.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb119.VAL") #! Record("BSOC:LI06:G4:EqpWarn_calc",260,18,0,1,"BSOC:LI06:G4:EqpWarn_calc") #! Field("BSOC:LI06:G4:EqpWarn_calc.INPA",16777215,0,"BSOC:LI06:G4:EqpWarn_calc.INPA") #! Link("BSOC:LI06:G4:EqpWarn_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb119.VAL") #! Field("BSOC:LI06:G4:EqpWarn_calc.INPB",16777215,1,"BSOC:LI06:G4:EqpWarn_calc.INPB") #! Field("BSOC:LI06:G4:EqpWarn_calc.OUT",16777215,1,"BSOC:LI06:G4:EqpWarn_calc.OUT") #! Link("BSOC:LI06:G4:EqpWarn_calc.OUT","BSOC:LI06:G4:EqpWarn.VAL") #! Record("BSOC:LI06:G4:EqpWarn",500,20,0,0,"BSOC:LI06:G4:EqpWarn") #! Field("BSOC:LI06:G4:EqpWarn.VAL",16777215,1,"BSOC:LI06:G4:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi117") { field(DESC, "Port LI06_BSOIC_Rd bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 117, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:LI06:1:PLCHB_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi117Valid") { field(INPA, "PLC:LI06:PP01:Bi117.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:1:PLCHB_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:1:PLCHB_calc") { field(INPA, "PLC:LI06:PP01:Bi117 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi117Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:1:PLCHB PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:1:PLCHB") { field(DESC, "BSOIC-PLC_Heartbeat") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb117",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb117") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb117.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb117.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb117.FLNK","BSOC:LI06:1:PLCHB_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb117.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb117.VAL") #! Record("BSOC:LI06:1:PLCHB_calc",260,18,0,1,"BSOC:LI06:1:PLCHB_calc") #! Field("BSOC:LI06:1:PLCHB_calc.INPA",16777215,0,"BSOC:LI06:1:PLCHB_calc.INPA") #! Link("BSOC:LI06:1:PLCHB_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb117.VAL") #! Field("BSOC:LI06:1:PLCHB_calc.INPB",16777215,1,"BSOC:LI06:1:PLCHB_calc.INPB") #! Field("BSOC:LI06:1:PLCHB_calc.OUT",16777215,1,"BSOC:LI06:1:PLCHB_calc.OUT") #! Link("BSOC:LI06:1:PLCHB_calc.OUT","BSOC:LI06:1:PLCHB.VAL") #! Record("BSOC:LI06:1:PLCHB",500,20,0,0,"BSOC:LI06:1:PLCHB") #! Field("BSOC:LI06:1:PLCHB.VAL",16777215,1,"BSOC:LI06:1:PLCHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi116") { field(DESC, "Port LI06_BSOIC_Rd bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 116, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:09:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi116Valid") { field(INPA, "PLC:LI06:PP01:Bi116.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:09:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:09:ChOk_calc") { field(INPA, "PLC:LI06:PP01:Bi116 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi116Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:09:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:09:ChOk") { field(DESC, "BSOIC-CH1_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb116",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb116") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb116.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb116.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb116.FLNK","BSOC:LI07:09:ChOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb116.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb116.VAL") #! Record("BSOC:LI07:09:ChOk_calc",260,18,0,1,"BSOC:LI07:09:ChOk_calc") #! Field("BSOC:LI07:09:ChOk_calc.INPA",16777215,0,"BSOC:LI07:09:ChOk_calc.INPA") #! Link("BSOC:LI07:09:ChOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb116.VAL") #! Field("BSOC:LI07:09:ChOk_calc.INPB",16777215,1,"BSOC:LI07:09:ChOk_calc.INPB") #! Field("BSOC:LI07:09:ChOk_calc.OUT",16777215,1,"BSOC:LI07:09:ChOk_calc.OUT") #! Link("BSOC:LI07:09:ChOk_calc.OUT","BSOC:LI07:09:ChOk.VAL") #! Record("BSOC:LI07:09:ChOk",500,20,0,0,"BSOC:LI07:09:ChOk") #! Field("BSOC:LI07:09:ChOk.VAL",16777215,1,"BSOC:LI07:09:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi115") { field(DESC, "Port LI06_BSOIC_Rd bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 115, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:10:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi115Valid") { field(INPA, "PLC:LI06:PP01:Bi115.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:10:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:10:ChOk_calc") { field(INPA, "PLC:LI06:PP01:Bi115 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi115Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:10:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:10:ChOk") { field(DESC, "BSOIC-CH2_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb115",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb115") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb115.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb115.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb115.FLNK","BSOC:LI07:10:ChOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb115.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb115.VAL") #! Record("BSOC:LI07:10:ChOk_calc",260,18,0,1,"BSOC:LI07:10:ChOk_calc") #! Field("BSOC:LI07:10:ChOk_calc.INPA",16777215,0,"BSOC:LI07:10:ChOk_calc.INPA") #! Link("BSOC:LI07:10:ChOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb115.VAL") #! Field("BSOC:LI07:10:ChOk_calc.INPB",16777215,1,"BSOC:LI07:10:ChOk_calc.INPB") #! Field("BSOC:LI07:10:ChOk_calc.OUT",16777215,1,"BSOC:LI07:10:ChOk_calc.OUT") #! Link("BSOC:LI07:10:ChOk_calc.OUT","BSOC:LI07:10:ChOk.VAL") #! Record("BSOC:LI07:10:ChOk",500,20,0,0,"BSOC:LI07:10:ChOk") #! Field("BSOC:LI07:10:ChOk.VAL",16777215,1,"BSOC:LI07:10:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi114") { field(DESC, "Port LI06_BSOIC_Rd bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 114, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G3:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi114Valid") { field(INPA, "PLC:LI06:PP01:Bi114.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G3:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G3:ChOk_calc") { field(INPA, "PLC:LI06:PP01:Bi114 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi114Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G3:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G3:ChOk") { field(DESC, "BSOIC-CH3_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb114",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb114") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb114.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb114.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb114.FLNK","BSOC:LI06:G3:ChOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb114.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb114.VAL") #! Record("BSOC:LI06:G3:ChOk_calc",260,18,0,1,"BSOC:LI06:G3:ChOk_calc") #! Field("BSOC:LI06:G3:ChOk_calc.INPA",16777215,0,"BSOC:LI06:G3:ChOk_calc.INPA") #! Link("BSOC:LI06:G3:ChOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb114.VAL") #! Field("BSOC:LI06:G3:ChOk_calc.INPB",16777215,1,"BSOC:LI06:G3:ChOk_calc.INPB") #! Field("BSOC:LI06:G3:ChOk_calc.OUT",16777215,1,"BSOC:LI06:G3:ChOk_calc.OUT") #! Link("BSOC:LI06:G3:ChOk_calc.OUT","BSOC:LI06:G3:ChOk.VAL") #! Record("BSOC:LI06:G3:ChOk",500,20,0,0,"BSOC:LI06:G3:ChOk") #! Field("BSOC:LI06:G3:ChOk.VAL",16777215,1,"BSOC:LI06:G3:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi113") { field(DESC, "Port LI06_BSOIC_Rd bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 113, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:G4:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi113Valid") { field(INPA, "PLC:LI06:PP01:Bi113.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:G4:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:G4:ChOk_calc") { field(INPA, "PLC:LI06:PP01:Bi113 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi113Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:G4:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:G4:ChOk") { field(DESC, "BSOIC-CH4_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb113",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb113") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb113.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb113.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb113.FLNK","BSOC:LI06:G4:ChOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb113.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb113.VAL") #! Record("BSOC:LI06:G4:ChOk_calc",260,18,0,1,"BSOC:LI06:G4:ChOk_calc") #! Field("BSOC:LI06:G4:ChOk_calc.INPA",16777215,0,"BSOC:LI06:G4:ChOk_calc.INPA") #! Link("BSOC:LI06:G4:ChOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb113.VAL") #! Field("BSOC:LI06:G4:ChOk_calc.INPB",16777215,1,"BSOC:LI06:G4:ChOk_calc.INPB") #! Field("BSOC:LI06:G4:ChOk_calc.OUT",16777215,1,"BSOC:LI06:G4:ChOk_calc.OUT") #! Link("BSOC:LI06:G4:ChOk_calc.OUT","BSOC:LI06:G4:ChOk.VAL") #! Record("BSOC:LI06:G4:ChOk",500,20,0,0,"BSOC:LI06:G4:ChOk") #! Field("BSOC:LI06:G4:ChOk.VAL",16777215,1,"BSOC:LI06:G4:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi112") { field(DESC, "Port LI06_BSOIC_Rd bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 112, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI07:11N:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi112Valid") { field(INPA, "PLC:LI06:PP01:Bi112.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI07:11N:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI07:11N:ChOk_calc") { field(INPA, "PLC:LI06:PP01:Bi112 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi112Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI07:11N:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI07:11N:ChOk") { field(DESC, "BSOIC-CH5_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb112",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb112") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb112.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb112.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb112.FLNK","BSOC:LI07:11N:ChOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb112.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb112.VAL") #! Record("BSOC:LI07:11N:ChOk_calc",260,18,0,1,"BSOC:LI07:11N:ChOk_calc") #! Field("BSOC:LI07:11N:ChOk_calc.INPA",16777215,0,"BSOC:LI07:11N:ChOk_calc.INPA") #! Link("BSOC:LI07:11N:ChOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb112.VAL") #! Field("BSOC:LI07:11N:ChOk_calc.INPB",16777215,1,"BSOC:LI07:11N:ChOk_calc.INPB") #! Field("BSOC:LI07:11N:ChOk_calc.OUT",16777215,1,"BSOC:LI07:11N:ChOk_calc.OUT") #! Link("BSOC:LI07:11N:ChOk_calc.OUT","BSOC:LI07:11N:ChOk.VAL") #! Record("BSOC:LI07:11N:ChOk",500,20,0,0,"BSOC:LI07:11N:ChOk") #! Field("BSOC:LI07:11N:ChOk.VAL",16777215,1,"BSOC:LI07:11N:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:LI06:PP01:Bi127") { field(DESC, "Port LI06_BSOIC_Rd bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 127, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:LI06:N2:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:Bi127Valid") { field(INPA, "PLC:LI06:PP01:Bi127.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:LI06:N2:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:LI06:N2:ChOk_calc") { field(INPA, "PLC:LI06:PP01:Bi127 NPP NMS") field(INPB, "PLC:LI06:PP01:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:LI06:PP01:Bi127Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:LI06:N2:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:LI06:N2:ChOk") { field(DESC, "BSOIC-CH6_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:LI06:PP01:LI06_BSOIC_Rdb127",20,19,0,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb127") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb127.FLNK",16777215,1,"PLC:LI06:PP01:LI06_BSOIC_Rdb127.FLNK") #! Link("PLC:LI06:PP01:LI06_BSOIC_Rdb127.FLNK","BSOC:LI06:N2:ChOk_calc") #! Field("PLC:LI06:PP01:LI06_BSOIC_Rdb127.VAL",16777215,0,"PLC:LI06:PP01:LI06_BSOIC_Rdb127.VAL") #! Record("BSOC:LI06:N2:ChOk_calc",260,18,0,1,"BSOC:LI06:N2:ChOk_calc") #! Field("BSOC:LI06:N2:ChOk_calc.INPA",16777215,0,"BSOC:LI06:N2:ChOk_calc.INPA") #! Link("BSOC:LI06:N2:ChOk_calc.INPA","PLC:LI06:PP01:LI06_BSOIC_Rdb127.VAL") #! Field("BSOC:LI06:N2:ChOk_calc.INPB",16777215,1,"BSOC:LI06:N2:ChOk_calc.INPB") #! Field("BSOC:LI06:N2:ChOk_calc.OUT",16777215,1,"BSOC:LI06:N2:ChOk_calc.OUT") #! Link("BSOC:LI06:N2:ChOk_calc.OUT","BSOC:LI06:N2:ChOk.VAL") #! Record("BSOC:LI06:N2:ChOk",500,20,0,0,"BSOC:LI06:N2:ChOk") #! Field("BSOC:LI06:N2:ChOk.VAL",16777215,1,"BSOC:LI06:N2:ChOk.VAL") record(bo, "BSOC:LI07:09:SReset") { field(DESC, "BSOIC-Soft_Reset_G1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI07:10:SReset") { field(DESC, "BSOIC-Soft_Reset_G2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI06:G3:SReset") { field(DESC, "BSOIC-Soft_Reset_G3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 5, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI06:G4:SReset") { field(DESC, "BSOIC-Soft_Reset_G4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 4, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI07:11N:SReset") { field(DESC, "BSOIC-Soft_Reset_N1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI06:N2:SReset") { field(DESC, "BSOIC-Soft_Reset_N2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 2, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI06:1:SResetAll") { field(DESC, "BSOIC-Soft_Reset_All") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 1, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:LI06:1:SPauseHB") { field(DESC, "BSOIC-Soft_Pause_Hb") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Pause") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:LI06:PP01:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:LI06:PP01:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:LI06:PP01:TABLE_CYCLER") { field( OUT, "PLC:LI06:PP01:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:LI06:PP01:SEG_CYCLER") { field( OUT, "PLC:LI06:PP01:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:LI06:PP01:TABLE_9_SEG_1") { field( INPA, "PLC:LI06:PP01:REQ_TABLE CP") field( INPB, "PLC:LI06:PP01:REQ_SEG CP") field( INPC, "PLC:LI06:PP01:REQ_TABLE_IN CP") field( INPD, "PLC:LI06:PP01:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:LI06:PP01:TABLE_1_SEG_1") { field( INPA, "PLC:LI06:PP01:REQ_TABLE CP") field( INPB, "PLC:LI06:PP01:REQ_SEG CP") field( INPC, "PLC:LI06:PP01:REQ_TABLE_IN CP") field( INPD, "PLC:LI06:PP01:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI06:PP01:REQ_TABLE_OUT") { field(OUTA, "PLC:LI06:PP01:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:LI06:PP01:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:LI06:PP01:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:LI06:PP01:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:LI06:PP01:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:LI06:PP01:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:LI06:PP01:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:LI06:PP01:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:LI06:PP01:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT0 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT1 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT2 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT3 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT4 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT5 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT6 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:LI06:PP01:REQ_TABLE_OUT") field(INPB, "PLC:LI06:PP01:TABLE_BIT7 MS") field(INPC, "PLC:LI06:PP01:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI06:PP01:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:LI06:PP01:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:LI06:PP01:TABLE_BIT0 CP MS") field(INPB, "PLC:LI06:PP01:TABLE_BIT1 CP MS") field(INPC, "PLC:LI06:PP01:TABLE_BIT2 CP MS") field(INPD, "PLC:LI06:PP01:TABLE_BIT3 CP MS") field(INPE, "PLC:LI06:PP01:TABLE_BIT4 CP MS") field(INPF, "PLC:LI06:PP01:TABLE_BIT5 CP MS") field(INPG, "PLC:LI06:PP01:TABLE_BIT6 CP MS") field(INPH, "PLC:LI06:PP01:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI06:PP01:REQ_TABLE PP MS") #field(SDIS, "PLC:LI06:PP01:REQ_TABLE_OUT.PACT") } record(longout, "PLC:LI06:PP01:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:LI06:PP01:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:LI06:PP01:REQ_SEG_OUT") { field(OUTA, "PLC:LI06:PP01:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:LI06:PP01:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:LI06:PP01:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:LI06:PP01:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:LI06:PP01:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:LI06:PP01:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:LI06:PP01:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:LI06:PP01:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:LI06:PP01:REQ_SEG_IN.PACT") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT0 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT1 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT1 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT2 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT2 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT3 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT3 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT4 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT4 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT5 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT5 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT6 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT6 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:LI06:PP01:REQ_SEG_OUT") field(INPB, "PLC:LI06:PP01:SEG_BIT7 MS") field(INPC, "PLC:LI06:PP01:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:LI06:PP01:REQ_SEG_BIT7 PP") } record(calcout, "PLC:LI06:PP01:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:LI06:PP01:SEG_BIT0 CP MS") field(INPB, "PLC:LI06:PP01:SEG_BIT1 CP MS") field(INPC, "PLC:LI06:PP01:SEG_BIT2 CP MS") field(INPD, "PLC:LI06:PP01:SEG_BIT3 CP MS") field(INPE, "PLC:LI06:PP01:SEG_BIT4 CP MS") field(INPF, "PLC:LI06:PP01:SEG_BIT5 CP MS") field(INPG, "PLC:LI06:PP01:SEG_BIT6 CP MS") field(INPH, "PLC:LI06:PP01:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:LI06:PP01:REQ_SEG PP MS") field(SDIS, "PLC:LI06:PP01:REQ_SEG_OUT.PACT") } record(bi, "PLC:LI06:PP01:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:PWLED") { field(DESC, "PLC-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:RUNLED") { field(DESC, "PLC-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:DIAGLED") { field(DESC, "PLC-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:FAULTLED") { field(DESC, "PLC-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:IFAULTLED") { field(DESC, "PLC-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:OFAULTLED") { field(DESC, "PLC-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:LI06:PP01:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Rd, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:LI06:PP01:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(LI06_BSOIC_Wrt, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:LI06:PP01:w0") { field(DESC, "Checksum word 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:w1") { field(DESC, "Checksum word 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 2, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:LI06:PP01:CHECKSUM_SDIS") { field(INPA, "PLC:LI06:PP01:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:LI06:PP01:w3") { field(DESC, "Checksum word 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 3, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:CHECKSUM_SAFE_calc") { field(INPA, "PLC:LI06:PP01:w3 PP MS") field(INPB, "PLC:LI06:PP01:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI06:PP01:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:LI06:PP01:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI06:PP01:w4") { field(DESC, "Checksum word 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 4, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:PROJ_CHECKSUM_calc") { field(INPA, "PLC:LI06:PP01:w4 NPP MS") field(INPB, "PLC:LI06:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI06:PP01:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI06:PP01:w5") { field(DESC, "Checksum word 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 5, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:DAY_MONTH_calc") { field(INPA, "PLC:LI06:PP01:w5 NPP MS") field(INPB, "PLC:LI06:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI06:PP01:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:LI06:PP01:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:LI06:PP01:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:LI06:PP01:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:LI06:PP01:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI06:PP01:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 6, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:PROJ_YEAR_calc") { field(INPA, "PLC:LI06:PP01:w6 NPP MS") field(INPB, "PLC:LI06:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI06:PP01:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:LI06:PP01:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 7, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:OP_HRS_MSB_calc") { field(INPA, "PLC:LI06:PP01:w7 NPP MS") field(INPB, "PLC:LI06:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI06:PP01:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(LI06_BSOIC_Wd, 8, 0xFFFF, 1)") field(FLNK, "PLC:LI06:PP01:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:LI06:PP01:OP_HRS_LSB_calc") { field(INPA, "PLC:LI06:PP01:w8 NPP MS") field(INPB, "PLC:LI06:PP01:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:LI06:PP01:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:LI06:PP01:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:LI06:PP01:OP_HOURS") { field(INPA, "PLC:LI06:PP01:OP_HRS_MSB CP MS") field(INPB, "PLC:LI06:PP01:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:LI06:PP01:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:LI06:PP01:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:LI06:PP01:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI06_BSOIC_Rd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI06:PP01:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI06:PP01:RDHist.PROC") } record(waveform,"PLC:LI06:PP01:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI06_BSOIC_Rd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI06:PP01:RDHistTimeAxis.PROC") } record(waveform,"PLC:LI06:PP01:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI06_BSOIC_Rd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI06:PP01:RDReadOK.PROC") } record(longout,"PLC:LI06:PP01:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI06_BSOIC_Rd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI06:PP01:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Rd 0)READ_OK") field(FLNK,"PLC:LI06:PP01:RDWriteOK.PROC") } record(longin,"PLC:LI06:PP01:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Rd 0)WRITE_OK") field(FLNK,"PLC:LI06:PP01:RDIOErrors.PROC") } record(longin,"PLC:LI06:PP01:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Rd 0)IO_ERRORS") field(FLNK,"PLC:LI06:PP01:RDLastIOTime.PROC") } record(longin,"PLC:LI06:PP01:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Rd 0)LAST_IO_TIME") field(FLNK,"PLC:LI06:PP01:RDMaxIOTime.PROC") } record(longin,"PLC:LI06:PP01:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Rd 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI06:PP01:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI06_BSOIC_Wrt 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI06:PP01:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI06:PP01:WRTHist.PROC") } record(waveform,"PLC:LI06:PP01:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI06_BSOIC_Wrt 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI06:PP01:WRTHistTimeAxis.PROC") } record(waveform,"PLC:LI06:PP01:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI06_BSOIC_Wrt 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI06:PP01:WRTReadOK.PROC") } record(longout,"PLC:LI06:PP01:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI06_BSOIC_Wrt 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI06:PP01:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wrt 0)READ_OK") field(FLNK,"PLC:LI06:PP01:WRTWriteOK.PROC") } record(longin,"PLC:LI06:PP01:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wrt 0)WRITE_OK") field(FLNK,"PLC:LI06:PP01:WRTIOErrors.PROC") } record(longin,"PLC:LI06:PP01:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wrt 0)IO_ERRORS") field(FLNK,"PLC:LI06:PP01:WRTLastIOTime.PROC") } record(longin,"PLC:LI06:PP01:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wrt 0)LAST_IO_TIME") field(FLNK,"PLC:LI06:PP01:WRTMaxIOTime.PROC") } record(longin,"PLC:LI06:PP01:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wrt 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:LI06:PP01:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(LI06_BSOIC_Wd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:LI06:PP01:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:LI06:PP01:WDHist.PROC") } record(waveform,"PLC:LI06:PP01:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI06_BSOIC_Wd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI06:PP01:WDHistTimeAxis.PROC") } record(waveform,"PLC:LI06:PP01:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(LI06_BSOIC_Wd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:LI06:PP01:WDReadOK.PROC") } record(longout,"PLC:LI06:PP01:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(LI06_BSOIC_Wd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:LI06:PP01:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wd 0)READ_OK") field(FLNK,"PLC:LI06:PP01:WDWriteOK.PROC") } record(longin,"PLC:LI06:PP01:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wd 0)WRITE_OK") field(FLNK,"PLC:LI06:PP01:WDIOErrors.PROC") } record(longin,"PLC:LI06:PP01:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wd 0)IO_ERRORS") field(FLNK,"PLC:LI06:PP01:WDLastIOTime.PROC") } record(longin,"PLC:LI06:PP01:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wd 0)LAST_IO_TIME") field(FLNK,"PLC:LI06:PP01:WDMaxIOTime.PROC") } record(longin,"PLC:LI06:PP01:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(LI06_BSOIC_Wd 0)MAX_IO_TIME") } record(ai, "BSOC:LI02:05:GAMMAPLC") { field(DESC, "LI01-03 BSOLNW05 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/118 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI02:05:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI02:05:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI02:05:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI02:05:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI02:05:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI02:05:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(ai, "BSOC:LI04:06:GAMMAPLC") { field(DESC, "LI04-05 BSOLNW06 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/458 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI04:06:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI04:06:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI04:06:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI04:06:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI04:06:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI04:06:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(ai, "BSOC:LI04:07:GAMMAPLC") { field(DESC, "LI04-05 BSOLNW07 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/460 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI04:07:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI04:07:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI04:07:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI04:07:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI04:07:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI04:07:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(ai, "BSOC:LI05:08:GAMMAPLC") { field(DESC, "LI04-05 BSOLNW08 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/462 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI05:08:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI05:08:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI05:08:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI05:08:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI05:08:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI05:08:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(ai, "BSOC:LI07:09:GAMMAPLC") { field(DESC, "LI06-07 BSOLNW09 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/498 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI07:09:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI07:09:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI07:09:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI07:09:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI07:09:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI07:09:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(ai, "BSOC:LI07:10:GAMMAPLC") { field(DESC, "LI06-07 BSOLNW10 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/500 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI07:10:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI07:10:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:LI07:10:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:LI07:10:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:LI07:10:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:LI07:10:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI02:05:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI02:05:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI02:05:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI02:05:WARNINGMODE") field(INPB, "BSOC:LI02:05:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI02:05:WARNINGMODE",3440,3386,0,1,"BSOC:LI02:05:WARNINGMODE") #! Field("BSOC:LI02:05:WARNINGMODE.VAL",16777215,1,"BSOC:LI02:05:WARNINGMODE.VAL") #! Field("BSOC:LI02:05:WARNINGMODE.FLNK",16777215,1,"BSOC:LI02:05:WARNINGMODE.FLNK") #! Link("BSOC:LI02:05:WARNINGMODE.FLNK","BSOC:LI02:05:CALCWARNING") #! Record("BSOC:LI02:05:CALCWARNING",3760,3400,0,0,"BSOC:LI02:05:CALCWARNING") #! Field("BSOC:LI02:05:CALCWARNING.INPA",16777215,0,"BSOC:LI02:05:CALCWARNING.INPA") #! Link("BSOC:LI02:05:CALCWARNING.INPA","BSOC:LI02:05:WARNINGMODE.VAL") #! Field("BSOC:LI02:05:CALCWARNING.INPB",16777215,1,"BSOC:LI02:05:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI04:06:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI04:06:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI04:06:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI04:06:WARNINGMODE") field(INPB, "BSOC:LI04:06:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI04:06:WARNINGMODE",3440,3386,0,1,"BSOC:LI04:06:WARNINGMODE") #! Field("BSOC:LI04:06:WARNINGMODE.VAL",16777215,1,"BSOC:LI04:06:WARNINGMODE.VAL") #! Field("BSOC:LI04:06:WARNINGMODE.FLNK",16777215,1,"BSOC:LI04:06:WARNINGMODE.FLNK") #! Link("BSOC:LI04:06:WARNINGMODE.FLNK","BSOC:LI04:06:CALCWARNING") #! Record("BSOC:LI04:06:CALCWARNING",3760,3400,0,0,"BSOC:LI04:06:CALCWARNING") #! Field("BSOC:LI04:06:CALCWARNING.INPA",16777215,0,"BSOC:LI04:06:CALCWARNING.INPA") #! Link("BSOC:LI04:06:CALCWARNING.INPA","BSOC:LI04:06:WARNINGMODE.VAL") #! Field("BSOC:LI04:06:CALCWARNING.INPB",16777215,1,"BSOC:LI04:06:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI04:14N:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI04:14N:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI04:14N:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI04:14N:WARNINGMODE") field(INPB, "BSOC:LI04:14N:COM:NeutronDoseRate.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI04:14N:WARNINGMODE",3440,3386,0,1,"BSOC:LI04:14N:WARNINGMODE") #! Field("BSOC:LI04:14N:WARNINGMODE.VAL",16777215,1,"BSOC:LI04:14N:WARNINGMODE.VAL") #! Field("BSOC:LI04:14N:WARNINGMODE.FLNK",16777215,1,"BSOC:LI04:14N:WARNINGMODE.FLNK") #! Link("BSOC:LI04:14N:WARNINGMODE.FLNK","BSOC:LI04:14N:CALCWARNING") #! Record("BSOC:LI04:14N:CALCWARNING",3760,3400,0,0,"BSOC:LI04:14N:CALCWARNING") #! Field("BSOC:LI04:14N:CALCWARNING.INPA",16777215,0,"BSOC:LI04:14N:CALCWARNING.INPA") #! Link("BSOC:LI04:14N:CALCWARNING.INPA","BSOC:LI04:14N:WARNINGMODE.VAL") #! Field("BSOC:LI04:14N:CALCWARNING.INPB",16777215,1,"BSOC:LI04:14N:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI04:07:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI04:07:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI04:07:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI04:07:WARNINGMODE") field(INPB, "BSOC:LI04:07:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI04:07:WARNINGMODE",3440,3386,0,1,"BSOC:LI04:07:WARNINGMODE") #! Field("BSOC:LI04:07:WARNINGMODE.VAL",16777215,1,"BSOC:LI04:07:WARNINGMODE.VAL") #! Field("BSOC:LI04:07:WARNINGMODE.FLNK",16777215,1,"BSOC:LI04:07:WARNINGMODE.FLNK") #! Link("BSOC:LI04:07:WARNINGMODE.FLNK","BSOC:LI04:07:CALCWARNING") #! Record("BSOC:LI04:07:CALCWARNING",3760,3400,0,0,"BSOC:LI04:07:CALCWARNING") #! Field("BSOC:LI04:07:CALCWARNING.INPA",16777215,0,"BSOC:LI04:07:CALCWARNING.INPA") #! Link("BSOC:LI04:07:CALCWARNING.INPA","BSOC:LI04:07:WARNINGMODE.VAL") #! Field("BSOC:LI04:07:CALCWARNING.INPB",16777215,1,"BSOC:LI04:07:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI05:08:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI05:08:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI05:08:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI05:08:WARNINGMODE") field(INPB, "BSOC:LI05:08:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI05:08:WARNINGMODE",3440,3386,0,1,"BSOC:LI05:08:WARNINGMODE") #! Field("BSOC:LI05:08:WARNINGMODE.VAL",16777215,1,"BSOC:LI05:08:WARNINGMODE.VAL") #! Field("BSOC:LI05:08:WARNINGMODE.FLNK",16777215,1,"BSOC:LI05:08:WARNINGMODE.FLNK") #! Link("BSOC:LI05:08:WARNINGMODE.FLNK","BSOC:LI05:08:CALCWARNING") #! Record("BSOC:LI05:08:CALCWARNING",3760,3400,0,0,"BSOC:LI05:08:CALCWARNING") #! Field("BSOC:LI05:08:CALCWARNING.INPA",16777215,0,"BSOC:LI05:08:CALCWARNING.INPA") #! Link("BSOC:LI05:08:CALCWARNING.INPA","BSOC:LI05:08:WARNINGMODE.VAL") #! Field("BSOC:LI05:08:CALCWARNING.INPB",16777215,1,"BSOC:LI05:08:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI05:15N:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI05:15N:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI05:15N:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI05:15N:WARNINGMODE") field(INPB, "BSOC:LI05:15N:COM:NeutronDoseRate.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI05:15N:WARNINGMODE",3440,3386,0,1,"BSOC:LI05:15N:WARNINGMODE") #! Field("BSOC:LI05:15N:WARNINGMODE.VAL",16777215,1,"BSOC:LI05:15N:WARNINGMODE.VAL") #! Field("BSOC:LI05:15N:WARNINGMODE.FLNK",16777215,1,"BSOC:LI05:15N:WARNINGMODE.FLNK") #! Link("BSOC:LI05:15N:WARNINGMODE.FLNK","BSOC:LI05:15N:CALCWARNING") #! Record("BSOC:LI05:15N:CALCWARNING",3760,3400,0,0,"BSOC:LI05:15N:CALCWARNING") #! Field("BSOC:LI05:15N:CALCWARNING.INPA",16777215,0,"BSOC:LI05:15N:CALCWARNING.INPA") #! Link("BSOC:LI05:15N:CALCWARNING.INPA","BSOC:LI05:15N:WARNINGMODE.VAL") #! Field("BSOC:LI05:15N:CALCWARNING.INPB",16777215,1,"BSOC:LI05:15N:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI07:09:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI07:09:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI07:09:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI07:09:WARNINGMODE") field(INPB, "BSOC:LI07:09:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI07:09:WARNINGMODE",3440,3386,0,1,"BSOC:LI07:09:WARNINGMODE") #! Field("BSOC:LI07:09:WARNINGMODE.VAL",16777215,1,"BSOC:LI07:09:WARNINGMODE.VAL") #! Field("BSOC:LI07:09:WARNINGMODE.FLNK",16777215,1,"BSOC:LI07:09:WARNINGMODE.FLNK") #! Link("BSOC:LI07:09:WARNINGMODE.FLNK","BSOC:LI07:09:CALCWARNING") #! Record("BSOC:LI07:09:CALCWARNING",3760,3400,0,0,"BSOC:LI07:09:CALCWARNING") #! Field("BSOC:LI07:09:CALCWARNING.INPA",16777215,0,"BSOC:LI07:09:CALCWARNING.INPA") #! Link("BSOC:LI07:09:CALCWARNING.INPA","BSOC:LI07:09:WARNINGMODE.VAL") #! Field("BSOC:LI07:09:CALCWARNING.INPB",16777215,1,"BSOC:LI07:09:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI07:11N:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI07:11N:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI07:11N:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI07:11N:WARNINGMODE") field(INPB, "BSOC:LI07:11N:COM:NeutronDoseRate.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI07:11N:WARNINGMODE",3440,3386,0,1,"BSOC:LI07:11N:WARNINGMODE") #! Field("BSOC:LI07:11N:WARNINGMODE.VAL",16777215,1,"BSOC:LI07:11N:WARNINGMODE.VAL") #! Field("BSOC:LI07:11N:WARNINGMODE.FLNK",16777215,1,"BSOC:LI07:11N:WARNINGMODE.FLNK") #! Link("BSOC:LI07:11N:WARNINGMODE.FLNK","BSOC:LI07:11N:CALCWARNING") #! Record("BSOC:LI07:11N:CALCWARNING",3760,3400,0,0,"BSOC:LI07:11N:CALCWARNING") #! Field("BSOC:LI07:11N:CALCWARNING.INPA",16777215,0,"BSOC:LI07:11N:CALCWARNING.INPA") #! Link("BSOC:LI07:11N:CALCWARNING.INPA","BSOC:LI07:11N:WARNINGMODE.VAL") #! Field("BSOC:LI07:11N:CALCWARNING.INPB",16777215,1,"BSOC:LI07:11N:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:LI07:10:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:LI07:10:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:LI07:10:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:LI07:10:WARNINGMODE") field(INPB, "BSOC:LI07:10:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:LI07:10:WARNINGMODE",3440,3386,0,1,"BSOC:LI07:10:WARNINGMODE") #! Field("BSOC:LI07:10:WARNINGMODE.VAL",16777215,1,"BSOC:LI07:10:WARNINGMODE.VAL") #! Field("BSOC:LI07:10:WARNINGMODE.FLNK",16777215,1,"BSOC:LI07:10:WARNINGMODE.FLNK") #! Link("BSOC:LI07:10:WARNINGMODE.FLNK","BSOC:LI07:10:CALCWARNING") #! Record("BSOC:LI07:10:CALCWARNING",3760,3400,0,0,"BSOC:LI07:10:CALCWARNING") #! Field("BSOC:LI07:10:CALCWARNING.INPA",16777215,0,"BSOC:LI07:10:CALCWARNING.INPA") #! Link("BSOC:LI07:10:CALCWARNING.INPA","BSOC:LI07:10:WARNINGMODE.VAL") #! Field("BSOC:LI07:10:CALCWARNING.INPB",16777215,1,"BSOC:LI07:10:CALCWARNING.INPB") record(longin, "RADM:LI01:1:DoseRate") { field(DESC, "LI01-03 RDM #1 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/126 T=WORD") } record(longin, "RADM:LI01:2:DoseRate") { field(DESC, "LI01-03 RDM #2 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/128 T=WORD") } record(longin, "PPS:LI01:1:SearchTimer") { field(DESC, "LI01-07 Search Timer (units?)") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/144 T=WORD") } record(longin, "PPS:LI01:1:BeamImminentTimer") { field(DESC, "LI01-07 Beam Imnnt Wrn timer sec") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/146 T=BYTE") } record(longin, "PLC:LI03:2A:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2A_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/226 T=WORD") } record(longin, "PLC:LI03:2B:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2B_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/228 T=WORD") } record(longin, "PLC:LI03:2A:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2A_Int_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/264 T=WORD") } record(longin, "PLC:LI03:2B:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2B_Int_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/282 T=WORD") } record(longin, "PLC:LI03:3A:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3A_Stp_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/284 T=WORD") } record(longin, "PLC:LI03:3B:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3B_Stp_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/286 T=WORD") } record(longin, "PLC:LI03:3A:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3A_Stp_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/322 T=WORD") } record(longin, "PLC:LI03:3B:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3B_Stp_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/340 T=WORD") } record(longin, "PLC:LI06:2A:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2A_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/342 T=WORD") } record(longin, "PLC:LI06:2B:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2B_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/344 T=WORD") } record(longin, "PLC:LI06:2A:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2A_Int_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/380 T=WORD") } record(longin, "PLC:LI06:2B:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2B_Int_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/398 T=WORD") } record(longin, "PLC:LI06:3A:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3A_Stp_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/400 T=WORD") } record(longin, "PLC:LI06:3B:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3B_Stp_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/402 T=WORD") } record(longin, "PLC:LI06:3A:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3A_Stp_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/438 T=WORD") } record(longin, "PLC:LI06:3B:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3B_Stp_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/456 T=WORD") } record(longin, "RADM:LI04:1:DoseRate") { field(DESC, "LI04-05 RDM #1 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/466 T=WORD") } record(longin, "RADM:LI04:2:DoseRate") { field(DESC, "LI04-05 RDM #2 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/468 T=WORD") } record(longin, "RADM:LI06:1:DoseRate") { field(DESC, "LI06-07 RDM #1 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/506 T=WORD") } record(longin, "RADM:LI06:2:DoseRate") { field(DESC, "LI06-07 RDM #2 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/508 T=WORD") } record(bi, "PLC:LI01:1:DC:Ok") { field(DESC, "LI01-03 24VDC-PS DC OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:DC:Status") { field(DESC, "LI01-03 24VDC-PS Status OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=2") field(ZNAM, "FALSE") field(ONAM, "TRUE") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:DC:UpsFaultStatus") { field(DESC, "LI01-03 DC UPS Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:DC:UpsMode") { field(DESC, "LI01-03 DC UPS in Battery Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=4") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI01:1:DC:UpsCharging") { field(DESC, "LI01-03 DC UPS Battery Charging") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=5") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI01:1:ZoneSwitchFault") { field(DESC, "LI01-03 Zone Network Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:ChainASwitchFault") { field(DESC, "LI01-03 ChA Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/134 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:ChainBSwitchFault") { field(DESC, "LI01-03 ChB Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:Locked") { field(DESC, "S1 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:Locked") { field(DESC, "S2 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=2") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:Locked") { field(DESC, "S3 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=3") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AvLitContA") { field(DESC, "S1 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AvLitContB") { field(DESC, "S1 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AudioPlay") { field(DESC, "LI01-LI03 TOA EV-20R message playing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/135 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:AvLitContA") { field(DESC, "S2 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/136 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:AvLitContB") { field(DESC, "S2 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/136 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:AvLitContA") { field(DESC, "S3 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/136 T=BYTE B=2") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:AvLitContB") { field(DESC, "S3 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/136 T=BYTE B=3") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresetPr1W") { field(DESC, "Preset PR-1W") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/137 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresetPr3H") { field(DESC, "Preset PR-3H") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/137 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EnableKeyswitch") { field(DESC, "LI01-03 RF En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/137 T=BYTE B=4") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI01:1:Fault") { field(DESC, "LI01-LI03 Local RDM OK 1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/137 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI01:2:Fault") { field(DESC, "LI01-LI03 Local RDM OK 2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/137 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:MwFanCont") { field(DESC, "S1 MW fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/138 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:MwFanSwitch") { field(DESC, "S1 MW Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/138 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwFanCont") { field(DESC, "S2 MW fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/138 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwFanSwitch") { field(DESC, "S2 MW Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/138 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwFanCont") { field(DESC, "S3 MW fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/138 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwFanSwitch") { field(DESC, "S3 MW Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/138 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:MwFanInhibit") { field(DESC, "Inhibit S1 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwFanInhibit") { field(DESC, "Inhibit S2 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:YmYellow") { field(DESC, "LI01-07 Y/M Light Yellow") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:YmMagenta") { field(DESC, "LI01-07 Y/M Light Magenta") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PermAccess") { field(DESC, "LI01-07 Zone in Permitted Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:CtrlAccess") { field(DESC, "LI01-07 Zone in Controlled Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:RestAccess") { field(DESC, "LI01-07 Zone in Restricted Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:NoAccess") { field(DESC, "LI01-07 Zone in No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/139 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:MaglockOn") { field(DESC, "S1 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI02:1:MaglockOn") { field(DESC, "S2 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI03:1:MaglockOn") { field(DESC, "S3 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=2") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:1:MwFanInhibit") { field(DESC, "Inhibit S3 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:AcPlcHeartbeat") { field(DESC, "LI01-07 PLC HB AC_PLC Pulse Source") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:LlrfPmtIntrtd") { field(DESC, "LI01-07 LLRF Permit interrupted") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:Lockout") { field(DESC, "LI01-07 Door Lockout") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/140 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AllDoorGateClsd") { field(DESC, "LI01-07 All RT primtr Drs/Gates Clsd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/141 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:HbA") { field(DESC, "LI01-03 Sfty Intlk PLC Ch-A HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/141 T=BYTE B=1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:HbB") { field(DESC, "LI01-03 Sfty Intlk PLC Ch-B HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/141 T=BYTE B=2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:HbA") { field(DESC, "LI01-03 Stopper Ctrl PLC Ch-A HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/141 T=BYTE B=3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:HbB") { field(DESC, "LI01-03 Stopper Ctrl PLC Ch-B HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/141 T=BYTE B=4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LGUN:1:LaserOff") { field(DESC, "Injector Laser is OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/141 T=BYTE B=6") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:1:TestMode") { field(DESC, "LI01-07 In TEST Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=0") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:1:DC:Ok") { field(DESC, "LI04-05 24VDC-PS DC OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:1:DC:Status") { field(DESC, "LI04-05 24VDC-PS Status OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=2") field(ZNAM, "FALSE") field(ONAM, "TRUE") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:1:DC:UpsFaultStatus") { field(DESC, "LI04-05 DC UPS Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:1:DC:UpsMode") { field(DESC, "LI04-05 DC UPS in Battery Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=4") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI03:1:DC:UpsCharging") { field(DESC, "LI04-05 DC UPS Battery Charging") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=5") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI03:1:ZoneSwitchFault") { field(DESC, "LI04-05 Zone Network Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:1:ChainASwitchFault") { field(DESC, "LI04-05 ChA Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/474 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:1:ChainBSwitchFault") { field(DESC, "LI04-05 ChB Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:Locked") { field(DESC, "S4 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:Locked") { field(DESC, "S5 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=2") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:AvLitContA") { field(DESC, "S4 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=3") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:AvLitContB") { field(DESC, "S4 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=4") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:AvLitContA") { field(DESC, "S5 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:AvLitContB") { field(DESC, "S5 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:AudioPlay") { field(DESC, "LI04-05 TOA EV-20R message playing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/475 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AllZoneClear") { field(DESC, "LI01-07 All zone CLEAR summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=0") field(ZNAM, "NOT_CLEAR") field(ONAM, "CLEAR") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "ODM:LI01:1:Sumy") { field(DESC, "LI01-07 ODM Sum OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI01:1:Sumy") { field(DESC, "LI01-07 RDM OK Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AllZoneHazOff") { field(DESC, "LI01-07 All Zn/Haz off Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=3") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:AllKeybank") { field(DESC, "LI01-07 All Kbnk Cplt Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:SYSW:3:Off") { field(DESC, "LI01-07 West Global is in OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=5") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:SYSW:3:ZoneEntry") { field(DESC, "LI01-07 W Gbl in Zn Entry Enabld") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=6") field(ZNAM, "Entry_Not_Set") field(ONAM, "Entry_Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:SYSW:3:BeamReady") { field(DESC, "LI01-07 W Gbl in Rdy for Beam") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/476 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresetPr5H") { field(DESC, "Preset PR-5H") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/477 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EnableKeyswitch") { field(DESC, "LI04-05 RF En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/477 T=BYTE B=4") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI04:1:Fault") { field(DESC, "LI04-LI05 Local RDM OK 1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/477 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI04:2:Fault") { field(DESC, "LI04-LI05 Local RDM OK 2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/477 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI01:1:BypKeyswitch") { field(DESC, "LI01-07 RDM Bypass KeySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/478 T=BYTE B=0") field(ZNAM, "Normal") field(ONAM, "Override") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "ODM:LI01:1:BypKeyswitch") { field(DESC, "LI01-07 ODM Bypass keySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/478 T=BYTE B=1") field(ZNAM, "Normal") field(ONAM, "Override") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:1:FanCont") { field(DESC, "S4 fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/478 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:FanSwitch") { field(DESC, "S4 Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/478 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:FanCont") { field(DESC, "S5 fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/478 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:FanSwitch") { field(DESC, "S5 Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/478 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwFanInhibit") { field(DESC, "Inhibit S4 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/479 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwFanInhibit") { field(DESC, "Inhibit S5 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/479 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:MaglockOn") { field(DESC, "S4 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/480 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI05:1:MaglockOn") { field(DESC, "S5 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/480 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:HbA") { field(DESC, "LI04-05 Sfty Intlk PLC Ch-A HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/481 T=BYTE B=1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:HbB") { field(DESC, "LI04-05 Sfty Intlk PLC Ch-B HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/481 T=BYTE B=2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:HbA") { field(DESC, "LI04-05 Stopper Ctrl PLC Ch-A HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/481 T=BYTE B=3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:HbB") { field(DESC, "LI04-05 Stopper Ctrl PLC Ch-B HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/481 T=BYTE B=4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:1:DC:Ok") { field(DESC, "LI06-07 24VDC-PS DC OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:1:DC:Status") { field(DESC, "LI06-07 24VDC-PS Status OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=2") field(ZNAM, "FALSE") field(ONAM, "TRUE") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:1:DC:UpsFaultStatus") { field(DESC, "LI06-07 DC UPS Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:1:DC:UpsMode") { field(DESC, "LI06-07 DC UPS in Battery Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=4") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI06:1:DC:UpsCharging") { field(DESC, "LI06-07 DC UPS Battery Charging") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=5") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI06:1:ZoneSwitchFault") { field(DESC, "LI06-07 Zone Network Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:1:ChainASwitchFault") { field(DESC, "LI06-07 ChA Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/514 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:1:ChainBSwitchFault") { field(DESC, "LI06-07 ChB Saf Net Sw Flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:Locked") { field(DESC, "S6 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:Locked") { field(DESC, "S7 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=2") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MaglockOn") { field(DESC, "LI07/LI08 Bndry Gate Maglock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=3") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:1:Locked") { field(DESC, "LI07/LI08 Bndry Gate Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=4") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:AvLitContA") { field(DESC, "S6 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:AvLitContB") { field(DESC, "S6 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:AudioPlay") { field(DESC, "LI06-07 TOA EV-20R message playing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/515 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:AvLitContA") { field(DESC, "S7 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/516 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:AvLitContB") { field(DESC, "S7 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/516 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:FanKeyswitch") { field(DESC, "S07 LINAC fan KeySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/517 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresetPr7E") { field(DESC, "Preset PR-7E") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/517 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EnableKeyswitch") { field(DESC, "LI06-07 RF En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/517 T=BYTE B=4") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI06:1:Fault") { field(DESC, "LI06-LI07 Local RDM OK 1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/517 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI06:2:Fault") { field(DESC, "LI06-LI07 Local RDM OK 2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/517 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:FanCont") { field(DESC, "S6 fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/518 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:FanSwitch") { field(DESC, "S6 Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/518 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:FanCont") { field(DESC, "S7 fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/518 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:FanSwitch") { field(DESC, "S7 Fan safety sw fback stat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/518 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwFanInhibit") { field(DESC, "Inhibit S6 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/518 T=BYTE B=6") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwFanInhibit") { field(DESC, "Inhibit S7 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/518 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:FanInibit") { field(DESC, "Inhibit S7 LINAC Supply fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/519 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:MaglockOn") { field(DESC, "S6 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/520 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI07:1:MaglockOn") { field(DESC, "S7 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/520 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:HbA") { field(DESC, "LI06-07 Sfty Intlk PLC Ch-A HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/521 T=BYTE B=1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:HbB") { field(DESC, "LI06-07 Sfty Intlk PLC Ch-B HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/521 T=BYTE B=2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:HbA") { field(DESC, "LI06-07 Stopper Ctrl PLC Ch-A HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/521 T=BYTE B=3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:HbB") { field(DESC, "LI06-07 Stopper Ctrl PLC Ch-B HB flt B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/521 T=BYTE B=4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bo, "DOOR:LI04:1:Release") { field(DESC, "LI01-07 Reset Interlocks") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/101 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:InterlockReset") { field(DESC, "LI01-07 Reset Interlocks") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/101 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqSearchReset") { field(DESC, "LI01-07 ACR Remote Reset Search") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/101 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqIntSearch") { field(DESC, "LI01-07 Interrupt Preserved Search") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/101 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI01:1:SafeLinkFaultReset") { field(DESC, "LI01-07 Reset SafeLink Comm. Fault") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/101 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI01:1:ReqSuspIntHrtbt") { field(DESC, "LI01-07 Pause PLC Heartbeat Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/102 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI01:3:ReqSuspStpHrtbt") { field(DESC, "LI01-LI03 Soft Pause PLC HB Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/103 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L2B:0200:StpFAC-IS3PmtOn") { field(DESC, "Req CM02-07 RF (FAC-IS3-6) ON") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/103 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L2B:0200:StpFAC-IS3PmtOff") { field(DESC, "Req CM02-07 RF (FAC-IS3-6) OFF") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/104 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L2B:0800:StpFAC-IS7PmtOn") { field(DESC, "Req CM08-13 RF (FAC-IS7-9) ON") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/104 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L2B:0800:StpFAC-IS7PmtOff") { field(DESC, "Req CM08-13 RF (FAC-IS7-9) OFF") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/104 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqPermAccess") { field(DESC, "LI01-07 Bail to P/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/105 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqCtrlAccess") { field(DESC, "LI01-07 Bail to C/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/105 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqRestAccess") { field(DESC, "LI01-07 Bail to R/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/105 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqNoAccess") { field(DESC, "LI01-07 Bail to N/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/105 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI04:1:KeybankRelease") { field(DESC, "S4 MW KB1 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/105 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI04:2:KeybankRelease") { field(DESC, "S4 MW KB2 Release") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/105 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqOpnHatch") { field(DESC, "S1 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/106 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI01:1:ReqClsHatch") { field(DESC, "S1 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/106 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI02:1:ReqOpnHatch") { field(DESC, "S2 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/106 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI02:1:ReqClsHatch") { field(DESC, "S2 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/106 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI03:1:ReqOpnHatch") { field(DESC, "S3 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI03:1:ReqClsHatch") { field(DESC, "S3 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI04:1:ReqOpnHatch") { field(DESC, "S4 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI04:1:ReqClsHatch") { field(DESC, "S4 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI05:1:ReqOpnHatch") { field(DESC, "S5 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI05:1:ReqClsHatch") { field(DESC, "S5 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI06:1:ReqOpnHatch") { field(DESC, "S6 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI06:1:ReqClsHatch") { field(DESC, "S6 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/107 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI07:1:ReqOpnHatch") { field(DESC, "S7 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/108 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI07:1:ReqClsHatch") { field(DESC, "S7 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/108 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI01:1:ClearHBFault") { field(DESC, "LI01-07 Clear HB Fault Warning") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/109 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L2B:1400:StpFAC-IS10PmtOn") { field(DESC, "Req CM14-21 RF (FAC-IS10-13) ON") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/114 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L2B:1400:StpFAC-IS10PmtOff") { field(DESC, "Req CM14-21 RF (FAC-IS10-13) OFF") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/114 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI03:3:ReqSuspStpHrtbt") { field(DESC, "LI04-LI05 Soft Pause PLC HB Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/116 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L3B:2200:StpFAC-IS14PmtOn") { field(DESC, "Req CM22-29 RF (FAC-IS14-17) ON") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/122 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L3B:2200:StpFAC-IS14PmtOff") { field(DESC, "Req CM22-29 RF (FAC-IS14-17) OFF") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/122 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L3B:3000:StpFAC-IS18PmtOn") { field(DESC, "Req CM30-35 RF (FAC-IS18-20) ON") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/122 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L3B:3000:StpFAC-IS18PmtOff") { field(DESC, "Req CM30-35 RF (FAC-IS18-20) OFF") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/122 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI06:3:ReqSuspStpHrtbt") { field(DESC, "LI06-LI07 Soft Pause PLC HB Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI01_PP01/124 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bi, "DOOR:LI01:1:Closed") { field(DESC, "RT-IN S1 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/56 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:Hatch") { field(DESC, "RT-IN S1 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/56 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:EExit") { field(DESC, "RT-IN S1 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/56 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:2:Closed") { field(DESC, "RT-IN S1 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/56 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:Closed") { field(DESC, "RT-IN S2 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/56 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:Hatch") { field(DESC, "RT-IN S2 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/56 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:EExit") { field(DESC, "RT-IN S2 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:2:Closed") { field(DESC, "RT-IN S2 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:Closed") { field(DESC, "RT-IN S3 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:Hatch") { field(DESC, "RT-IN S3 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:EExit") { field(DESC, "RT-IN S3 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:2:Closed") { field(DESC, "RT-IN S3 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:Preset") { field(DESC, "RT-IN S1 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI01:2:Preset") { field(DESC, "RT-IN S1 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/57 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI02:1:Preset") { field(DESC, "RT-IN S2 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI02:2:Preset") { field(DESC, "RT-IN S2 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:1:Preset") { field(DESC, "RT-IN S3 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:2:Preset") { field(DESC, "RT-IN S3 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI01:1:MwEOString") { field(DESC, "RT-IN S1 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwEOString") { field(DESC, "RT-IN S2 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwEOString") { field(DESC, "RT-IN S3 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOString") { field(DESC, "RT-IN S1 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/58 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:OFAULT") { field(DESC, "Pilz_2_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/59 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:IFAULT") { field(DESC, "Pilz_2_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/59 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:FAULT") { field(DESC, "Pilz_2_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/59 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:DIAG") { field(DESC, "Pilz_2_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/59 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:RUN") { field(DESC, "Pilz_2_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/59 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:COMM") { field(DESC, "Pilz_2_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/59 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:EOString") { field(DESC, "RT-IN S2 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/64 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:EOString") { field(DESC, "RT-IN S3 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/64 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:Gate") { field(DESC, "RT-IN LI00/01 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/64 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:SearchReset") { field(DESC, "RT-IN Inj/LI00 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/64 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:ClosedLatch") { field(DESC, "LAT S1 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/64 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:HatchLatch") { field(DESC, "LAT S1 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/64 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:EExitLatch") { field(DESC, "LAT S1 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/65 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:2:ClosedLatch") { field(DESC, "LAT S1 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/65 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:ClosedLatch") { field(DESC, "LAT S2 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/65 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:HatchLatch") { field(DESC, "LAT S2 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/65 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:EExitLatch") { field(DESC, "LAT S2 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/65 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:2:ClosedLatch") { field(DESC, "LAT S2 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/65 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:ClosedLatch") { field(DESC, "LAT S3 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/66 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:HatchLatch") { field(DESC, "LAT S3 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/66 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:EExitLatch") { field(DESC, "LAT S3 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/66 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:2:ClosedLatch") { field(DESC, "LAT S3 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/66 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:MwEOStringLatch") { field(DESC, "LAT S1 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/67 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwEOStringLatch") { field(DESC, "LAT S2 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/67 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwEOStringLatch") { field(DESC, "LAT S3 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/67 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOStringLatch") { field(DESC, "LAT S1 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/67 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:EOStringLatch") { field(DESC, "LAT S2 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/67 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:EOStringLatch") { field(DESC, "LAT S3 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/67 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:GateLatch") { field(DESC, "LAT LI00/01 Housg Bndry Gate Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/68 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:SearchResetOut") { field(DESC, "RT-OUT LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/68 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresetSet") { field(DESC, "S1 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/68 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:PresetSet") { field(DESC, "S1 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/68 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresSearch") { field(DESC, "S1 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/68 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresSearchTimer") { field(DESC, "S1 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI02:1:PresetSet") { field(DESC, "S2 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:2:PresetSet") { field(DESC, "S2 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:PresSearch") { field(DESC, "S2 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:PresSearchTimer") { field(DESC, "S2 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=4") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI03:1:PresetSet") { field(DESC, "S3 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:2:PresetSet") { field(DESC, "S3 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresSearch") { field(DESC, "S3 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/69 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresSearchTimer") { field(DESC, "S3 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI01:2:Li04SafeLinkComOk") { field(DESC, "LI01-03 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:CommHeartbeat") { field(DESC, "LI01-03 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneIntact") { field(DESC, "LI01-03 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=3") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:Li04SafeLinkComOkLatch") { field(DESC, "LAT LI01-03 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneNoAccess") { field(DESC, "LI01-03 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=5") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneInterlock") { field(DESC, "LI01-03 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:EOSumyLatch") { field(DESC, "LI01-03 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/70 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:OFAULT") { field(DESC, "Pilz_3_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/175 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:IFAULT") { field(DESC, "Pilz_3_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/175 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:FAULT") { field(DESC, "Pilz_3_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/175 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:DIAG") { field(DESC, "Pilz_3_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/175 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:RUN") { field(DESC, "Pilz_3_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/175 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:COMM") { field(DESC, "Pilz_3_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/175 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:PlcHeartbeat") { field(DESC, "LI01-LI03 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/182 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:CommHeartbeat") { field(DESC, "LI01-LI03 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/182 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI01:1:Sumy") { field(DESC, "LI01-LI03 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/182 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI01:1:StpPermit") { field(DESC, "LI01 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/183 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:XInterlockIn") { field(DESC, "LI01-LI03 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/183 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI01:1:Enable") { field(DESC, "LI01-LI03 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/183 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:0200:StpFAC-IS3ClsCmd") { field(DESC, "CM02-03 RF SSA (FAC-IS3) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:H100:StpFAC-IS4ClsCmd") { field(DESC, "3.9 GHz CM HLA/B SSA (FAC-IS4) Cont Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0400:StpFAC-IS5ClsCmd") { field(DESC, "CM04-05 RF SSA (FAC-IS5) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0600:StpFAC-IS6ClsCmd") { field(DESC, "CM06-07 RF SSA (FAC-IS6) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0800:StpFAC-IS7ClsCmd") { field(DESC, "CM08-09 RF SSA (FAC-IS7) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=4") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1000:StpFAC-IS8ClsCmd") { field(DESC, "CM10-11 RF SSA (FAC-IS8) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=5") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1200:StpFAC-IS9ClsCmd") { field(DESC, "CM12-13 RF SSA (FAC-IS9) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/184 T=BYTE B=6") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:0200:StpFAC-IS3IsOff") { field(DESC, "CM02-03 RF SSA (FAC-IS3) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L1B:H100:StpFAC-IS4IsOff") { field(DESC, "3.9 GHz CM HLA/HLB RF SSA (FAC-IS4) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0400:StpFAC-IS5IsOff") { field(DESC, "CM04-05 RF SSA (FAC-IS5) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0600:StpFAC-IS6IsOff") { field(DESC, "CM06-07 RF SSA (FAC-IS6) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0800:StpFAC-IS7IsOff") { field(DESC, "CM08-09 RF SSA (FAC-IS7) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=4") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:1000:StpFAC-IS8IsOff") { field(DESC, "CM10-11 RF SSA (FAC-IS8) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=5") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:1200:StpFAC-IS9IsOff") { field(DESC, "CM12-13 RF SSA (FAC-IS9) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/185 T=BYTE B=6") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI04:1:Closed") { field(DESC, "RT-IN S4 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:3:Closed") { field(DESC, "RT-IN S4 MW Stairway Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:Hatch") { field(DESC, "RT-IN S4 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:4:Closed") { field(DESC, "S4 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:Keybank") { field(DESC, "RT-IN S4 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:Keybank") { field(DESC, "RT-IN S4 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:EExit") { field(DESC, "RT-IN S4 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:2:Closed") { field(DESC, "RT-IN S4 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/230 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:Closed") { field(DESC, "RT-IN S5 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:Hatch") { field(DESC, "RT-IN S5 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:4:Closed") { field(DESC, "S5 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:EExit") { field(DESC, "RT-IN S5 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:2:Closed") { field(DESC, "RT-IN S5 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwEOString") { field(DESC, "RT-IN S4 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwEOString") { field(DESC, "RT-IN S5 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EOString") { field(DESC, "RT-IN S4 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/231 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:EOString") { field(DESC, "RT-IN S5 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:Preset") { field(DESC, "RT-IN S4 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:2:Preset") { field(DESC, "RT-IN S4 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:3:Preset") { field(DESC, "RT-IN S4 Stairway Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI05:1:Preset") { field(DESC, "RT-IN S5 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI05:2:Preset") { field(DESC, "RT-IN S5 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:2:XInterlockIn") { field(DESC, "RT-IN Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/232 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:OFAULT") { field(DESC, "Pilz_2_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/233 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:IFAULT") { field(DESC, "Pilz_2_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/233 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:FAULT") { field(DESC, "Pilz_2_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/233 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:DIAG") { field(DESC, "Pilz_2_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/233 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:RUN") { field(DESC, "Pilz_2_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/233 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:COMM") { field(DESC, "Pilz_2_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/233 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:LocSearchReset") { field(DESC, "RT-IN Search Reset Local KeySW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:YmOverrdStat") { field(DESC, "RT-IN LI01-07 Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=1") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:ClosedLatch") { field(DESC, "LAT S4 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:3:ClosedLatch") { field(DESC, "LAT S4 MW Stairway Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:HatchLatch") { field(DESC, "LAT S4 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:4:ClosedLatch") { field(DESC, "S4 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:KeybankLatch") { field(DESC, "LAT S4 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:KeybankLatch") { field(DESC, "LAT S4 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/238 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:EExitLatch") { field(DESC, "LAT S4 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:2:ClosedLatch") { field(DESC, "LAT S4 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:ClosedLatch") { field(DESC, "LAT S5 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:HatchLatch") { field(DESC, "LAT S5 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:4:ClosedLatch") { field(DESC, "S5 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:EExitLatch") { field(DESC, "LAT S5 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:2:ClosedLatch") { field(DESC, "LAT S5 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwEOStringLatch") { field(DESC, "LAT S4 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/239 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwEOStringLatch") { field(DESC, "LAT S5 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/240 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EOStringLatch") { field(DESC, "LAT S4 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/240 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:EOStringLatch") { field(DESC, "LAT S5 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/240 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:XRadReady") { field(DESC, "RT-OUT LI01-07 Rad Ready Cross-interlock") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/240 T=BYTE B=6") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneIntact") { field(DESC, "RT-OUT LI01-07 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/240 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneClear") { field(DESC, "RT-OUT LI01-07 Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/241 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneRadReady") { field(DESC, "RT-OUT LI01-07 Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/241 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PlayAudio") { field(DESC, "RT-OUT LI01-07 Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/241 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresetSet") { field(DESC, "S4 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/242 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:PresetSet") { field(DESC, "S4 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/242 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:3:PresetSet") { field(DESC, "S4 Stairway Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/242 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresSearch") { field(DESC, "S4 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresSearchTimer") { field(DESC, "S4 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=1") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI05:1:PresetSet") { field(DESC, "S5 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:2:PresetSet") { field(DESC, "S5 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresSearch") { field(DESC, "S5 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresSearchTimer") { field(DESC, "S5 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=5") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI04:1:ZoneKeybanks") { field(DESC, "LI04-05 Zone Local Keybanks Complete RT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneNoAccess") { field(DESC, "LI01-07 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/243 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneInterlock") { field(DESC, "LI01-07 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:BeamImminentTiming") { field(DESC, "LI01-07 Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI01:1:BeamImminentTimeCplt") { field(DESC, "LI01-07 Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:CommHeartbeat") { field(DESC, "LI01-07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li01SafeLinkComOk") { field(DESC, "SafeLink to LI01-03 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li06SafeLinkComOk") { field(DESC, "SafeLink to LI06-07 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li01SafeLinkComOkLatch") { field(DESC, "LAT SafeLink to LI01-03 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li06SafeLinkComOkLatch") { field(DESC, "LAT SafeLink to LI06-07 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/244 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOSumyLatch") { field(DESC, "LI01-07 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/245 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:OFAULT") { field(DESC, "Pilz_3_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/291 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:IFAULT") { field(DESC, "Pilz_3_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/291 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:FAULT") { field(DESC, "Pilz_3_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/291 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:DIAG") { field(DESC, "Pilz_3_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/291 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:RUN") { field(DESC, "Pilz_3_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/291 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:COMM") { field(DESC, "Pilz_3_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/291 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:PlcHeartbeat") { field(DESC, "LI04-LI05 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/298 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:CommHeartbeat") { field(DESC, "LI04-LI05 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/298 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI04:1:Sumy") { field(DESC, "LI04-LI05 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/298 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI04:1:StpPermit") { field(DESC, "LI04 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/299 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:3:XInterlockIn") { field(DESC, "LI04-LI05 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/299 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI04:1:Enable") { field(DESC, "LI04-LI05 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/299 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1400:StpFAC-IS10ClsCmd") { field(DESC, "CM14-15 RF SSA (FAC-IS10) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/300 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:1600:StpFAC-IS11ClsCmd") { field(DESC, "CM16-17 RF SSA (FAC-IS11) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/300 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:1800:StpFAC-IS12ClsCmd") { field(DESC, "CM18-19 RF SSA (FAC-IS12) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/300 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2000:StpFAC-IS13ClsCmd") { field(DESC, "CM20-21 RF SSA (FAC-IS13) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/300 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1400:StpFAC-IS10IsOff") { field(DESC, "LI04-LI05 CM14-15 RF SSA (FAC-IS10) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/301 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:1600:StpFAC-IS11IsOff") { field(DESC, "LI04-LI05 CM16-17 RF SSA (FAC-IS11) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/301 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:1800:StpFAC-IS12IsOff") { field(DESC, "LI04-LI05 CM18-19 RF SSA (FAC-IS12) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/301 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2000:StpFAC-IS13IsOff") { field(DESC, "LI04-LI05 CM20-21 RF SSA (FAC-IS13) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/301 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI06:1:Closed") { field(DESC, "RT-IN S6 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:Hatch") { field(DESC, "RT-IN S6 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:EExit") { field(DESC, "RT-IN S6 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:2:Closed") { field(DESC, "RT-IN S6 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:Closed") { field(DESC, "RT-IN S7 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:Hatch") { field(DESC, "RT-IN S7 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:EExit") { field(DESC, "RT-IN S7 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:2:Closed") { field(DESC, "RT-IN S7 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/346 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:Gate") { field(DESC, "RT-IN LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EExit") { field(DESC, "RT-IN LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwEOString") { field(DESC, "RT-IN S6 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwEOString") { field(DESC, "RT-IN S7 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOString") { field(DESC, "RT-IN S6 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EOString") { field(DESC, "RT-IN S7 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:Preset") { field(DESC, "RT-IN S6 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI06:2:Preset") { field(DESC, "RT-IN S6 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/347 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:1:Preset") { field(DESC, "RT-IN S7 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/348 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:2:Preset") { field(DESC, "RT-IN S7 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/348 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:2:SearchReset") { field(DESC, "RT-IN LI08-10ADIT Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/348 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:OFAULT") { field(DESC, "Pilz_2_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/349 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:IFAULT") { field(DESC, "Pilz_2_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/349 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:FAULT") { field(DESC, "Pilz_2_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/349 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:DIAG") { field(DESC, "Pilz_2_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/349 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:RUN") { field(DESC, "Pilz_2_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/349 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:COMM") { field(DESC, "Pilz_2_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/349 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:ClosedLatch") { field(DESC, "LAT S6 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:HatchLatch") { field(DESC, "LAT S6 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:EExitLatch") { field(DESC, "LAT S6 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:2:ClosedLatch") { field(DESC, "LAT S6 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:ClosedLatch") { field(DESC, "LAT S7 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:HatchLatch") { field(DESC, "LAT S7 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:EExitLatch") { field(DESC, "LAT S7 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:2:ClosedLatch") { field(DESC, "LAT S7 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/354 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:GateLatch") { field(DESC, "LAT LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/355 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EExitLatch") { field(DESC, "LAT LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/355 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwEOStringLatch") { field(DESC, "LAT S6 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/355 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwEOStringLatch") { field(DESC, "LAT S7 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/355 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOStringLatch") { field(DESC, "LAT S6 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/355 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EOStringLatch") { field(DESC, "LAT S7 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/355 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:SearchResetOut") { field(DESC, "RT-OUT LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/358 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresetSet") { field(DESC, "S6 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/358 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:2:PresetSet") { field(DESC, "S6 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/358 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresSearch") { field(DESC, "S6 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/358 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresSearchTimer") { field(DESC, "S6 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI07:1:PresetSet") { field(DESC, "S7 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:2:PresetSet") { field(DESC, "S7 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresSearch") { field(DESC, "S7 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresSearchTimer") { field(DESC, "S7 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=4") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI06:2:Li04SafeLinkComOk") { field(DESC, "LI06-07 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:CommHeartbeat") { field(DESC, "LI06-07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneIntact") { field(DESC, "LI06-07 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/359 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:Li04SafeLinkComOkLatch") { field(DESC, "LAT LI06-07 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/360 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneNoAccess") { field(DESC, "LI06-07 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/360 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneInterlock") { field(DESC, "LI06-07 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/360 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOSumyLatch") { field(DESC, "LI06-07 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/360 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:OFAULT") { field(DESC, "Pilz_3_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/407 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:IFAULT") { field(DESC, "Pilz_3_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/407 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:FAULT") { field(DESC, "Pilz_3_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/407 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:DIAG") { field(DESC, "Pilz_3_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/407 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:RUN") { field(DESC, "Pilz_3_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/407 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:COMM") { field(DESC, "Pilz_3_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/407 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:PlcHeartbeat") { field(DESC, "LI06-LI07 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/414 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:CommHeartbeat") { field(DESC, "LI06-LI07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/414 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI06:1:Sumy") { field(DESC, "LI06-LI07 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/414 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI06:1:StpPermit") { field(DESC, "LI06 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/415 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:XInterlockIn") { field(DESC, "LI06-LI07 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/415 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI06:1:Enable") { field(DESC, "LI06-LI07 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/415 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2200:StpFAC-IS14ClsCmd") { field(DESC, "CM22-23 RF SSA (FAC-IS14) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2400:StpFAC-IS15ClsCmd") { field(DESC, "CM24-25 RF SSA (FAC-IS15) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2600:StpFAC-IS16ClsCmd") { field(DESC, "CM26-27 RF SSA (FAC-IS16) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2800:StpFAC-IS17ClsCmd") { field(DESC, "CM28-29 RF SSA (FAC-IS17) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3000:StpFAC-IS18ClsCmd") { field(DESC, "CM30-31 RF SSA (FAC-IS18) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=4") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3200:StpFAC-IS19ClsCmd") { field(DESC, "CM32-33 RF SSA (FAC-IS19) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=5") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3400:StpFAC-IS20ClsCmd") { field(DESC, "CM34-35 RF SSA (FAC-IS20) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/416 T=BYTE B=6") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2200:StpFAC-IS14IsOff") { field(DESC, "LI06-LI07 CM22-23 RF SSA (FAC-IS14) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2400:StpFAC-IS15IsOff") { field(DESC, "LI06-LI07 CM24-25 RF SSA (FAC-IS15) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2600:StpFAC-IS16IsOff") { field(DESC, "LI06-LI07 CM26-27 RF SSA (FAC-IS16) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2800:StpFAC-IS17IsOff") { field(DESC, "LI06-LI07 CM28-29 RF SSA (FAC-IS17) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3000:StpFAC-IS18IsOff") { field(DESC, "LI06-LI07 CM30-31 RF SSA (FAC-IS18) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=4") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3200:StpFAC-IS19IsOff") { field(DESC, "LI06-LI07 CM32-33 RF SSA (FAC-IS19) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=5") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3400:StpFAC-IS20IsOff") { field(DESC, "LI06-LI07 CM34-35 RF SSA (FAC-IS20) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/417 T=BYTE B=6") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI01:1:ClosedA") { field(DESC, "RT-IN S1 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/74 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:HatchA") { field(DESC, "RT-IN S1 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/74 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:EExitA") { field(DESC, "RT-IN S1 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/74 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:2:ClosedA") { field(DESC, "RT-IN S1 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/74 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:ClosedA") { field(DESC, "RT-IN S2 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/74 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:HatchA") { field(DESC, "RT-IN S2 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/74 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:EExitA") { field(DESC, "RT-IN S2 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:2:ClosedA") { field(DESC, "RT-IN S2 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:ClosedA") { field(DESC, "RT-IN S3 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:HatchA") { field(DESC, "RT-IN S3 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:EExitA") { field(DESC, "RT-IN S3 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:2:ClosedA") { field(DESC, "RT-IN S3 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresetA") { field(DESC, "RT-IN S1 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI01:2:PresetA") { field(DESC, "RT-IN S1 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/75 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI02:1:PresetA") { field(DESC, "RT-IN S2 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI02:2:PresetA") { field(DESC, "RT-IN S2 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:1:PresetA") { field(DESC, "RT-IN S3 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:2:PresetA") { field(DESC, "RT-IN S3 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI01:1:MwEOStringA") { field(DESC, "RT-IN S1 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwEOStringA") { field(DESC, "RT-IN S2 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwEOStringA") { field(DESC, "RT-IN S3 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOStringA") { field(DESC, "RT-IN S1 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/76 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:OFAULTA") { field(DESC, "Pilz_2A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/77 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:IFAULTA") { field(DESC, "Pilz_2A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/77 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:FAULTA") { field(DESC, "Pilz_2A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/77 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:DIAGA") { field(DESC, "Pilz_2A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/77 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:RUNA") { field(DESC, "Pilz_2A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/77 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:COMMA") { field(DESC, "Pilz_2A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/77 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:EOStringA") { field(DESC, "RT-IN S2 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/82 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:EOStringA") { field(DESC, "RT-IN S3 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/82 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:GateA") { field(DESC, "RT-IN LI00/01 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/82 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:SearchResetA") { field(DESC, "RT-IN Inj/LI00 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/82 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:ClosedLatchA") { field(DESC, "LAT S1 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/82 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:HatchLatchA") { field(DESC, "LAT S1 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/82 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:EExitLatchA") { field(DESC, "LAT S1 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/83 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:2:ClosedLatchA") { field(DESC, "LAT S1 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/83 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:ClosedLatchA") { field(DESC, "LAT S2 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/83 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:HatchLatchA") { field(DESC, "LAT S2 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/83 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:EExitLatchA") { field(DESC, "LAT S2 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/83 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:2:ClosedLatchA") { field(DESC, "LAT S2 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/83 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:ClosedLatchA") { field(DESC, "LAT S3 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/84 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:HatchLatchA") { field(DESC, "LAT S3 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/84 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:EExitLatchA") { field(DESC, "LAT S3 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/84 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:2:ClosedLatchA") { field(DESC, "LAT S3 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/84 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:MwEOStringLatchA") { field(DESC, "LAT S1 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/85 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwEOStringLatchA") { field(DESC, "LAT S2 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/85 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwEOStringLatchA") { field(DESC, "LAT S3 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/85 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOStringLatchA") { field(DESC, "LAT S1 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/85 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:EOStringLatchA") { field(DESC, "LAT S2 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/85 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:EOStringLatchA") { field(DESC, "LAT S3 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/85 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:GateLatchA") { field(DESC, "LAT LI00/01 Housg Bndry Gate Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/86 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:SearchResetOutA") { field(DESC, "RT-OUT LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/86 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresetSetA") { field(DESC, "S1 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/86 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:PresetSetA") { field(DESC, "S1 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/86 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresSearchA") { field(DESC, "S1 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/86 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresSearchTimerA") { field(DESC, "S1 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI02:1:PresetSetA") { field(DESC, "S2 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:2:PresetSetA") { field(DESC, "S2 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:PresSearchA") { field(DESC, "S2 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:PresSearchTimerA") { field(DESC, "S2 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=4") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI03:1:PresetSetA") { field(DESC, "S3 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:2:PresetSetA") { field(DESC, "S3 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresSearchA") { field(DESC, "S3 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/87 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresSearchTimerA") { field(DESC, "S3 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI01:2:Li04SafeLinkComOkA") { field(DESC, "LI01-03 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:CommHeartbeatA") { field(DESC, "LI01-03 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneIntactA") { field(DESC, "LI01-03 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=3") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:Li04SafeLinkComOkLatchA") { field(DESC, "LAT LI01-03 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneNoAccessA") { field(DESC, "LI01-03 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=5") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneInterlockA") { field(DESC, "LI01-03 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:EOSumyLatchA") { field(DESC, "LI01-03 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/88 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:OFAULTA") { field(DESC, "Pilz_3A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/193 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:IFAULTA") { field(DESC, "Pilz_3A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/193 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:FAULTA") { field(DESC, "Pilz_3A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/193 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:DIAGA") { field(DESC, "Pilz_3A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/193 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:RUNA") { field(DESC, "Pilz_3A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/193 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:COMMA") { field(DESC, "Pilz_3A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/193 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:PlcHeartbeatA") { field(DESC, "LI01-LI03 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/200 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:CommHeartbeatA") { field(DESC, "LI01-LI03 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/200 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI01:1:SumyA") { field(DESC, "LI01-LI03 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/200 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI01:1:StpPermitA") { field(DESC, "LI01 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/201 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:XInterlockInA") { field(DESC, "LI01-LI03 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/201 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI01:1:EnableA") { field(DESC, "LI01-LI03 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/201 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:0200:StpFAC-IS3ClsCmdA") { field(DESC, "CM02-03 RF SSA (FAC-IS3) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:H100:StpFAC-IS4ClsCmdA") { field(DESC, "3.9 GHz CM HLA/B SSA (FAC-IS4) Cont Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0400:StpFAC-IS5ClsCmdA") { field(DESC, "CM04-05 RF SSA (FAC-IS5) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0600:StpFAC-IS6ClsCmdA") { field(DESC, "CM06-07 RF SSA (FAC-IS6) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0800:StpFAC-IS7ClsCmdA") { field(DESC, "CM08-09 RF SSA (FAC-IS7) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=4") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1000:StpFAC-IS8ClsCmdA") { field(DESC, "CM10-11 RF SSA (FAC-IS8) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=5") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1200:StpFAC-IS9ClsCmdA") { field(DESC, "CM12-13 RF SSA (FAC-IS9) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/202 T=BYTE B=6") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:0200:StpFAC-IS3IsOffA") { field(DESC, "CM02-03 RF SSA (FAC-IS3) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L1B:H100:StpFAC-IS4IsOffA") { field(DESC, "3.9 GHz CM HLA/HLB RF SSA (FAC-IS4) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0400:StpFAC-IS5IsOffA") { field(DESC, "CM04-05 RF SSA (FAC-IS5) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0600:StpFAC-IS6IsOffA") { field(DESC, "CM06-07 RF SSA (FAC-IS6) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0800:StpFAC-IS7IsOffA") { field(DESC, "CM08-09 RF SSA (FAC-IS7) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=4") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:1000:StpFAC-IS8IsOffA") { field(DESC, "CM10-11 RF SSA (FAC-IS8) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=5") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:1200:StpFAC-IS9IsOffA") { field(DESC, "CM12-13 RF SSA (FAC-IS9) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/203 T=BYTE B=6") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI04:1:ClosedA") { field(DESC, "RT-IN S4 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:3:ClosedA") { field(DESC, "RT-IN S4 MW Stairway Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:HatchA") { field(DESC, "RT-IN S4 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:4:ClosedA") { field(DESC, "S4 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:KeybankA") { field(DESC, "RT-IN S4 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:KeybankA") { field(DESC, "RT-IN S4 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:EExitA") { field(DESC, "RT-IN S4 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:2:ClosedA") { field(DESC, "RT-IN S4 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/248 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:ClosedA") { field(DESC, "RT-IN S5 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:HatchA") { field(DESC, "RT-IN S5 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:4:ClosedA") { field(DESC, "S5 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:EExitA") { field(DESC, "RT-IN S5 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:2:ClosedA") { field(DESC, "RT-IN S5 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwEOStringA") { field(DESC, "RT-IN S4 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwEOStringA") { field(DESC, "RT-IN S5 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EOStringA") { field(DESC, "RT-IN S4 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/249 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:EOStringA") { field(DESC, "RT-IN S5 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresetA") { field(DESC, "RT-IN S4 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:2:PresetA") { field(DESC, "RT-IN S4 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:3:PresetA") { field(DESC, "RT-IN S4 Stairway Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI05:1:PresetA") { field(DESC, "RT-IN S5 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI05:2:PresetA") { field(DESC, "RT-IN S5 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:2:XInterlockInA") { field(DESC, "RT-IN Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/250 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:OFAULTA") { field(DESC, "Pilz_2A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/251 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:IFAULTA") { field(DESC, "Pilz_2A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/251 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:FAULTA") { field(DESC, "Pilz_2A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/251 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:DIAGA") { field(DESC, "Pilz_2A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/251 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:RUNA") { field(DESC, "Pilz_2A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/251 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:COMMA") { field(DESC, "Pilz_2A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/251 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:LocSearchResetA") { field(DESC, "RT-IN Search Reset Local KeySW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:YmOverrdStatA") { field(DESC, "RT-IN LI01-07 Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=1") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:ClosedLatchA") { field(DESC, "LAT S4 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:3:ClosedLatchA") { field(DESC, "LAT S4 MW Stairway Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:HatchLatchA") { field(DESC, "LAT S4 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:4:ClosedLatchA") { field(DESC, "S4 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:KeybankLatchA") { field(DESC, "LAT S4 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:KeybankLatchA") { field(DESC, "LAT S4 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/256 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:EExitLatchA") { field(DESC, "LAT S4 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:2:ClosedLatchA") { field(DESC, "LAT S4 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:ClosedLatchA") { field(DESC, "LAT S5 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:HatchLatchA") { field(DESC, "LAT S5 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:4:ClosedLatchA") { field(DESC, "S5 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:EExitLatchA") { field(DESC, "LAT S5 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:2:ClosedLatchA") { field(DESC, "LAT S5 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwEOStringLatchA") { field(DESC, "LAT S4 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/257 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwEOStringLatchA") { field(DESC, "LAT S5 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/258 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EOStringLatchA") { field(DESC, "LAT S4 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/258 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:EOStringLatchA") { field(DESC, "LAT S5 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/258 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:XRadReadyA") { field(DESC, "RT-OUT LI01-07 Rad Ready Cross-interlock") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/258 T=BYTE B=6") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneIntactA") { field(DESC, "RT-OUT LI01-07 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/258 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneClearA") { field(DESC, "RT-OUT LI01-07 Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/259 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneRadReadyA") { field(DESC, "RT-OUT LI01-07 Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/259 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PlayAudioA") { field(DESC, "RT-OUT LI01-07 Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/259 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresetSetA") { field(DESC, "S4 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/260 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:PresetSetA") { field(DESC, "S4 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/260 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:3:PresetSetA") { field(DESC, "S4 Stairway Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/260 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresSearchA") { field(DESC, "S4 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresSearchTimerA") { field(DESC, "S4 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=1") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI05:1:PresetSetA") { field(DESC, "S5 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:2:PresetSetA") { field(DESC, "S5 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresSearchA") { field(DESC, "S5 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresSearchTimerA") { field(DESC, "S5 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=5") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI04:1:ZoneKeybanksA") { field(DESC, "LI04-05 Zone Local Keybanks Complete RT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneNoAccessA") { field(DESC, "LI01-07 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/261 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneInterlockA") { field(DESC, "LI01-07 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:BeamImminentTimingA") { field(DESC, "LI01-07 Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI01:1:BeamImminentTimeCpltA") { field(DESC, "LI01-07 Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:CommHeartbeatA") { field(DESC, "LI01-07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li01SafeLinkComOkA") { field(DESC, "SafeLink to LI01-03 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li06SafeLinkComOkA") { field(DESC, "SafeLink to LI06-07 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li01SafeLinkComOkLatchA") { field(DESC, "LAT SafeLink to LI01-03 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li06SafeLinkComOkLatchA") { field(DESC, "LAT SafeLink to LI06-07 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/262 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOSumyLatchA") { field(DESC, "LI01-07 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/263 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:OFAULTA") { field(DESC, "Pilz_3A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/309 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:IFAULTA") { field(DESC, "Pilz_3A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/309 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:FAULTA") { field(DESC, "Pilz_3A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/309 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:DIAGA") { field(DESC, "Pilz_3A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/309 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:RUNA") { field(DESC, "Pilz_3A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/309 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:COMMA") { field(DESC, "Pilz_3A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/309 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:PlcHeartbeatA") { field(DESC, "LI04-LI05 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/316 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:CommHeartbeatA") { field(DESC, "LI04-LI05 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/316 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI04:1:SumyA") { field(DESC, "LI04-LI05 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/316 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI04:1:StpPermitA") { field(DESC, "LI04 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/317 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:3:XInterlockInA") { field(DESC, "LI04-LI05 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/317 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI04:1:EnableA") { field(DESC, "LI04-LI05 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/317 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1400:StpFAC-IS10ClsCmdA") { field(DESC, "CM14-15 RF SSA (FAC-IS10) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/318 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:1600:StpFAC-IS11ClsCmdA") { field(DESC, "CM16-17 RF SSA (FAC-IS11) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/318 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:1800:StpFAC-IS12ClsCmdA") { field(DESC, "CM18-19 RF SSA (FAC-IS12) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/318 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2000:StpFAC-IS13ClsCmdA") { field(DESC, "CM20-21 RF SSA (FAC-IS13) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/318 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1400:StpFAC-IS10IsOffA") { field(DESC, "LI04-LI05 CM14-15 RF SSA (FAC-IS10) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/319 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:1600:StpFAC-IS11IsOffA") { field(DESC, "LI04-LI05 CM16-17 RF SSA (FAC-IS11) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/319 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:1800:StpFAC-IS12IsOffA") { field(DESC, "LI04-LI05 CM18-19 RF SSA (FAC-IS12) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/319 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2000:StpFAC-IS13IsOffA") { field(DESC, "LI04-LI05 CM20-21 RF SSA (FAC-IS13) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/319 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI06:1:ClosedA") { field(DESC, "RT-IN S6 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:HatchA") { field(DESC, "RT-IN S6 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:EExitA") { field(DESC, "RT-IN S6 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:2:ClosedA") { field(DESC, "RT-IN S6 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:ClosedA") { field(DESC, "RT-IN S7 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:HatchA") { field(DESC, "RT-IN S7 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:EExitA") { field(DESC, "RT-IN S7 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:2:ClosedA") { field(DESC, "RT-IN S7 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/364 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:GateA") { field(DESC, "RT-IN LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EExitA") { field(DESC, "RT-IN LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwEOStringA") { field(DESC, "RT-IN S6 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwEOStringA") { field(DESC, "RT-IN S7 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOStringA") { field(DESC, "RT-IN S6 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EOStringA") { field(DESC, "RT-IN S7 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresetA") { field(DESC, "RT-IN S6 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI06:2:PresetA") { field(DESC, "RT-IN S6 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/365 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:1:PresetA") { field(DESC, "RT-IN S7 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/366 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:2:PresetA") { field(DESC, "RT-IN S7 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/366 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:2:SearchResetA") { field(DESC, "RT-IN LI08-10ADIT Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/366 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:OFAULTA") { field(DESC, "Pilz_2A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/367 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:IFAULTA") { field(DESC, "Pilz_2A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/367 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:FAULTA") { field(DESC, "Pilz_2A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/367 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:DIAGA") { field(DESC, "Pilz_2A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/367 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:RUNA") { field(DESC, "Pilz_2A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/367 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:COMMA") { field(DESC, "Pilz_2A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/367 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:ClosedLatchA") { field(DESC, "LAT S6 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:HatchLatchA") { field(DESC, "LAT S6 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:EExitLatchA") { field(DESC, "LAT S6 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:2:ClosedLatchA") { field(DESC, "LAT S6 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:ClosedLatchA") { field(DESC, "LAT S7 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:HatchLatchA") { field(DESC, "LAT S7 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:EExitLatchA") { field(DESC, "LAT S7 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:2:ClosedLatchA") { field(DESC, "LAT S7 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/372 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:GateLatchA") { field(DESC, "LAT LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/373 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EExitLatchA") { field(DESC, "LAT LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/373 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwEOStringLatchA") { field(DESC, "LAT S6 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/373 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwEOStringLatchA") { field(DESC, "LAT S7 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/373 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOStringLatchA") { field(DESC, "LAT S6 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/373 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EOStringLatchA") { field(DESC, "LAT S7 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/373 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:SearchResetOutA") { field(DESC, "RT-OUT LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/376 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresetSetA") { field(DESC, "S6 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/376 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:2:PresetSetA") { field(DESC, "S6 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/376 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresSearchA") { field(DESC, "S6 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/376 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresSearchTimerA") { field(DESC, "S6 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI07:1:PresetSetA") { field(DESC, "S7 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:2:PresetSetA") { field(DESC, "S7 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresSearchA") { field(DESC, "S7 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresSearchTimerA") { field(DESC, "S7 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=4") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI06:2:Li04SafeLinkComOkA") { field(DESC, "LI06-07 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:CommHeartbeatA") { field(DESC, "LI06-07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneIntactA") { field(DESC, "LI06-07 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/377 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:Li04SafeLinkComOkLatchA") { field(DESC, "LAT LI06-07 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/378 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneNoAccessA") { field(DESC, "LI06-07 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/378 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneInterlockA") { field(DESC, "LI06-07 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/378 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOSumyLatchA") { field(DESC, "LI06-07 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/378 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:OFAULTA") { field(DESC, "Pilz_3A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/425 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:IFAULTA") { field(DESC, "Pilz_3A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/425 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:FAULTA") { field(DESC, "Pilz_3A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/425 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:DIAGA") { field(DESC, "Pilz_3A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/425 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:RUNA") { field(DESC, "Pilz_3A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/425 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:COMMA") { field(DESC, "Pilz_3A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/425 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:PlcHeartbeatA") { field(DESC, "LI06-LI07 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/432 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:CommHeartbeatA") { field(DESC, "LI06-LI07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/432 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI06:1:SumyA") { field(DESC, "LI06-LI07 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/432 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI06:1:StpPermitA") { field(DESC, "LI06 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/433 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:XInterlockInA") { field(DESC, "LI06-LI07 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/433 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI06:1:EnableA") { field(DESC, "LI06-LI07 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/433 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2200:StpFAC-IS14ClsCmdA") { field(DESC, "CM22-23 RF SSA (FAC-IS14) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2400:StpFAC-IS15ClsCmdA") { field(DESC, "CM24-25 RF SSA (FAC-IS15) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2600:StpFAC-IS16ClsCmdA") { field(DESC, "CM26-27 RF SSA (FAC-IS16) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2800:StpFAC-IS17ClsCmdA") { field(DESC, "CM28-29 RF SSA (FAC-IS17) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3000:StpFAC-IS18ClsCmdA") { field(DESC, "CM30-31 RF SSA (FAC-IS18) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=4") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3200:StpFAC-IS19ClsCmdA") { field(DESC, "CM32-33 RF SSA (FAC-IS19) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=5") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3400:StpFAC-IS20ClsCmdA") { field(DESC, "CM34-35 RF SSA (FAC-IS20) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/434 T=BYTE B=6") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2200:StpFAC-IS14IsOffA") { field(DESC, "LI06-LI07 CM22-23 RF SSA (FAC-IS14) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2400:StpFAC-IS15IsOffA") { field(DESC, "LI06-LI07 CM24-25 RF SSA (FAC-IS15) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2600:StpFAC-IS16IsOffA") { field(DESC, "LI06-LI07 CM26-27 RF SSA (FAC-IS16) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2800:StpFAC-IS17IsOffA") { field(DESC, "LI06-LI07 CM28-29 RF SSA (FAC-IS17) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3000:StpFAC-IS18IsOffA") { field(DESC, "LI06-LI07 CM30-31 RF SSA (FAC-IS18) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=4") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3200:StpFAC-IS19IsOffA") { field(DESC, "LI06-LI07 CM32-33 RF SSA (FAC-IS19) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=5") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3400:StpFAC-IS20IsOffA") { field(DESC, "LI06-LI07 CM34-35 RF SSA (FAC-IS20) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/435 T=BYTE B=6") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI01:1:ClosedB") { field(DESC, "RT-IN S1 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/92 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:HatchB") { field(DESC, "RT-IN S1 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/92 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:EExitB") { field(DESC, "RT-IN S1 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/92 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:2:ClosedB") { field(DESC, "RT-IN S1 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/92 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:ClosedB") { field(DESC, "RT-IN S2 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/92 T=BYTE B=6") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:HatchB") { field(DESC, "RT-IN S2 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/92 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:EExitB") { field(DESC, "RT-IN S2 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:2:ClosedB") { field(DESC, "RT-IN S2 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:ClosedB") { field(DESC, "RT-IN S3 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:HatchB") { field(DESC, "RT-IN S3 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:EExitB") { field(DESC, "RT-IN S3 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:2:ClosedB") { field(DESC, "RT-IN S3 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresetB") { field(DESC, "RT-IN S1 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI01:2:PresetB") { field(DESC, "RT-IN S1 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/93 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI02:1:PresetB") { field(DESC, "RT-IN S2 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI02:2:PresetB") { field(DESC, "RT-IN S2 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:1:PresetB") { field(DESC, "RT-IN S3 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI03:2:PresetB") { field(DESC, "RT-IN S3 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI01:1:MwEOStringB") { field(DESC, "RT-IN S1 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwEOStringB") { field(DESC, "RT-IN S2 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwEOStringB") { field(DESC, "RT-IN S3 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOStringB") { field(DESC, "RT-IN S1 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/94 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:OFAULTB") { field(DESC, "Pilz_2B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/95 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:IFAULTB") { field(DESC, "Pilz_2B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/95 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:FAULTB") { field(DESC, "Pilz_2B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/95 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:2:DIAGB") { field(DESC, "Pilz_2B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/95 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:RUNB") { field(DESC, "Pilz_2B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/95 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:COMMB") { field(DESC, "Pilz_2B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/95 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:EOStringB") { field(DESC, "RT-IN S2 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/100 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:EOStringB") { field(DESC, "RT-IN S3 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/100 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:GateB") { field(DESC, "RT-IN LI00/01 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/100 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:SearchResetB") { field(DESC, "RT-IN Inj/LI00 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/100 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:ClosedLatchB") { field(DESC, "LAT S1 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/100 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:HatchLatchB") { field(DESC, "LAT S1 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/100 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:1:EExitLatchB") { field(DESC, "LAT S1 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/101 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI01:2:ClosedLatchB") { field(DESC, "LAT S1 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/101 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:ClosedLatchB") { field(DESC, "LAT S2 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/101 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:HatchLatchB") { field(DESC, "LAT S2 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/101 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:1:EExitLatchB") { field(DESC, "LAT S2 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/101 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI02:2:ClosedLatchB") { field(DESC, "LAT S2 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/101 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:ClosedLatchB") { field(DESC, "LAT S3 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/102 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:HatchLatchB") { field(DESC, "LAT S3 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/102 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:1:EExitLatchB") { field(DESC, "LAT S3 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/102 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI03:2:ClosedLatchB") { field(DESC, "LAT S3 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/102 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:MwEOStringLatchB") { field(DESC, "LAT S1 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/103 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:MwEOStringLatchB") { field(DESC, "LAT S2 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/103 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:MwEOStringLatchB") { field(DESC, "LAT S3 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/103 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOStringLatchB") { field(DESC, "LAT S1 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/103 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:EOStringLatchB") { field(DESC, "LAT S2 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/103 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:EOStringLatchB") { field(DESC, "LAT S3 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/103 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:GateLatchB") { field(DESC, "LAT LI00/01 Housg Bndry Gate Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/104 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:SearchResetOutB") { field(DESC, "RT-OUT LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/104 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresetSetB") { field(DESC, "S1 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/104 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:PresetSetB") { field(DESC, "S1 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/104 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresSearchB") { field(DESC, "S1 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/104 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PresSearchTimerB") { field(DESC, "S1 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI02:1:PresetSetB") { field(DESC, "S2 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:2:PresetSetB") { field(DESC, "S2 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:PresSearchB") { field(DESC, "S2 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI02:1:PresSearchTimerB") { field(DESC, "S2 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=4") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI03:1:PresetSetB") { field(DESC, "S3 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:2:PresetSetB") { field(DESC, "S3 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresSearchB") { field(DESC, "S3 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/105 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI03:1:PresSearchTimerB") { field(DESC, "S3 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI01:2:Li04SafeLinkComOkB") { field(DESC, "LI01-03 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:CommHeartbeatB") { field(DESC, "LI01-03 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneIntactB") { field(DESC, "LI01-03 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=3") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:2:Li04SafeLinkComOkLatchB") { field(DESC, "LAT LI01-03 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneNoAccessB") { field(DESC, "LI01-03 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=5") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:ZoneInterlockB") { field(DESC, "LI01-03 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:EOSumyLatchB") { field(DESC, "LI01-03 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/106 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:OFAULTB") { field(DESC, "Pilz_3B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/211 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:IFAULTB") { field(DESC, "Pilz_3B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/211 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:FAULTB") { field(DESC, "Pilz_3B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/211 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:3:DIAGB") { field(DESC, "Pilz_3B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/211 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:RUNB") { field(DESC, "Pilz_3B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/211 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:COMMB") { field(DESC, "Pilz_3B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/211 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:PlcHeartbeatB") { field(DESC, "LI01-LI03 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/218 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI01:3:CommHeartbeatB") { field(DESC, "LI01-LI03 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/218 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI01:1:SumyB") { field(DESC, "LI01-LI03 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/218 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI01:1:StpPermitB") { field(DESC, "LI01 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/219 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:XInterlockInB") { field(DESC, "LI01-LI03 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/219 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI01:1:EnableB") { field(DESC, "LI01-LI03 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/219 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:0200:StpFAC-IS3ClsCmdB") { field(DESC, "CM02-03 RF SSA (FAC-IS3) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:H100:StpFAC-IS4ClsCmdB") { field(DESC, "3.9 GHz CM HLA/B SSA (FAC-IS4) Cont Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0400:StpFAC-IS5ClsCmdB") { field(DESC, "CM04-05 RF SSA (FAC-IS5) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0600:StpFAC-IS6ClsCmdB") { field(DESC, "CM06-07 RF SSA (FAC-IS6) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:0800:StpFAC-IS7ClsCmdB") { field(DESC, "CM08-09 RF SSA (FAC-IS7) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=4") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1000:StpFAC-IS8ClsCmdB") { field(DESC, "CM10-11 RF SSA (FAC-IS8) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=5") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1200:StpFAC-IS9ClsCmdB") { field(DESC, "CM12-13 RF SSA (FAC-IS9) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/220 T=BYTE B=6") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L1B:0200:StpFAC-IS3IsOffB") { field(DESC, "CM02-03 RF SSA (FAC-IS3) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L1B:H100:StpFAC-IS4IsOffB") { field(DESC, "3.9 GHz CM HLA/HLB RF SSA (FAC-IS4) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0400:StpFAC-IS5IsOffB") { field(DESC, "CM04-05 RF SSA (FAC-IS5) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0600:StpFAC-IS6IsOffB") { field(DESC, "CM06-07 RF SSA (FAC-IS6) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:0800:StpFAC-IS7IsOffB") { field(DESC, "CM08-09 RF SSA (FAC-IS7) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=4") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:1000:StpFAC-IS8IsOffB") { field(DESC, "CM10-11 RF SSA (FAC-IS8) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=5") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L2B:1200:StpFAC-IS9IsOffB") { field(DESC, "CM12-13 RF SSA (FAC-IS9) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/221 T=BYTE B=6") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI04:1:ClosedB") { field(DESC, "RT-IN S4 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:3:ClosedB") { field(DESC, "RT-IN S4 MW Stairway Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:HatchB") { field(DESC, "RT-IN S4 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:4:ClosedB") { field(DESC, "S4 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:KeybankB") { field(DESC, "RT-IN S4 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:KeybankB") { field(DESC, "RT-IN S4 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:EExitB") { field(DESC, "RT-IN S4 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:2:ClosedB") { field(DESC, "RT-IN S4 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/266 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:ClosedB") { field(DESC, "RT-IN S5 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:HatchB") { field(DESC, "RT-IN S5 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:4:ClosedB") { field(DESC, "S5 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:EExitB") { field(DESC, "RT-IN S5 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:2:ClosedB") { field(DESC, "RT-IN S5 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwEOStringB") { field(DESC, "RT-IN S4 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwEOStringB") { field(DESC, "RT-IN S5 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EOStringB") { field(DESC, "RT-IN S4 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/267 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:EOStringB") { field(DESC, "RT-IN S5 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresetB") { field(DESC, "RT-IN S4 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:2:PresetB") { field(DESC, "RT-IN S4 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:3:PresetB") { field(DESC, "RT-IN S4 Stairway Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI05:1:PresetB") { field(DESC, "RT-IN S5 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI05:2:PresetB") { field(DESC, "RT-IN S5 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI04:2:XInterlockInB") { field(DESC, "RT-IN Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/268 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:OFAULTB") { field(DESC, "Pilz_2B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/269 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:IFAULTB") { field(DESC, "Pilz_2B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/269 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:FAULTB") { field(DESC, "Pilz_2B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/269 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:2:DIAGB") { field(DESC, "Pilz_2B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/269 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:RUNB") { field(DESC, "Pilz_2B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/269 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:COMMB") { field(DESC, "Pilz_2B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/269 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:LocSearchResetB") { field(DESC, "RT-IN Search Reset Local KeySW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=0") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:YmOverrdStatB") { field(DESC, "RT-IN LI01-07 Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=1") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:ClosedLatchB") { field(DESC, "LAT S4 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:3:ClosedLatchB") { field(DESC, "LAT S4 MW Stairway Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:HatchLatchB") { field(DESC, "LAT S4 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:4:ClosedLatchB") { field(DESC, "S4 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:KeybankLatchB") { field(DESC, "LAT S4 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:KeybankLatchB") { field(DESC, "LAT S4 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/274 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:1:EExitLatchB") { field(DESC, "LAT S4 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI04:2:ClosedLatchB") { field(DESC, "LAT S4 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:ClosedLatchB") { field(DESC, "LAT S5 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:HatchLatchB") { field(DESC, "LAT S5 MW Hatch Closed LS ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:4:ClosedLatchB") { field(DESC, "S5 MW Exit to Gallery Rd Door Closed") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:1:EExitLatchB") { field(DESC, "LAT S5 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI05:2:ClosedLatchB") { field(DESC, "LAT S5 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:MwEOStringLatchB") { field(DESC, "LAT S4 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/275 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:MwEOStringLatchB") { field(DESC, "LAT S5 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/276 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:EOStringLatchB") { field(DESC, "LAT S4 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/276 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:EOStringLatchB") { field(DESC, "LAT S5 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/276 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:XRadReadyB") { field(DESC, "RT-OUT LI01-07 Rad Ready Cross-interlock") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/276 T=BYTE B=6") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneIntactB") { field(DESC, "RT-OUT LI01-07 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/276 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneClearB") { field(DESC, "RT-OUT LI01-07 Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/277 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneRadReadyB") { field(DESC, "RT-OUT LI01-07 Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/277 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:PlayAudioB") { field(DESC, "RT-OUT LI01-07 Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/277 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresetSetB") { field(DESC, "S4 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/278 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:2:PresetSetB") { field(DESC, "S4 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/278 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:3:PresetSetB") { field(DESC, "S4 Stairway Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/278 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresSearchB") { field(DESC, "S4 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:1:PresSearchTimerB") { field(DESC, "S4 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=1") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI05:1:PresetSetB") { field(DESC, "S5 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:2:PresetSetB") { field(DESC, "S5 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=3") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresSearchB") { field(DESC, "S5 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI05:1:PresSearchTimerB") { field(DESC, "S5 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=5") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI04:1:ZoneKeybanksB") { field(DESC, "LI04-05 Zone Local Keybanks Complete RT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneNoAccessB") { field(DESC, "LI01-07 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/279 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:ZoneInterlockB") { field(DESC, "LI01-07 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=0") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:BeamImminentTimingB") { field(DESC, "LI01-07 Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI01:1:BeamImminentTimeCpltB") { field(DESC, "LI01-07 Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:CommHeartbeatB") { field(DESC, "LI01-07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li01SafeLinkComOkB") { field(DESC, "SafeLink to LI01-03 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li06SafeLinkComOkB") { field(DESC, "SafeLink to LI06-07 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li01SafeLinkComOkLatchB") { field(DESC, "LAT SafeLink to LI01-03 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:2:Li06SafeLinkComOkLatchB") { field(DESC, "LAT SafeLink to LI06-07 Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/280 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:1:EOSumyLatchB") { field(DESC, "LI01-07 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/281 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:OFAULTB") { field(DESC, "Pilz_3B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/327 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:IFAULTB") { field(DESC, "Pilz_3B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/327 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:FAULTB") { field(DESC, "Pilz_3B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/327 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI03:3:DIAGB") { field(DESC, "Pilz_3B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/327 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:RUNB") { field(DESC, "Pilz_3B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/327 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:COMMB") { field(DESC, "Pilz_3B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/327 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:PlcHeartbeatB") { field(DESC, "LI04-LI05 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/334 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI03:3:CommHeartbeatB") { field(DESC, "LI04-LI05 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/334 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI04:1:SumyB") { field(DESC, "LI04-LI05 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/334 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI04:1:StpPermitB") { field(DESC, "LI04 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/335 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI04:3:XInterlockInB") { field(DESC, "LI04-LI05 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/335 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI04:1:EnableB") { field(DESC, "LI04-LI05 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/335 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1400:StpFAC-IS10ClsCmdB") { field(DESC, "CM14-15 RF SSA (FAC-IS10) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/336 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:1600:StpFAC-IS11ClsCmdB") { field(DESC, "CM16-17 RF SSA (FAC-IS11) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/336 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:1800:StpFAC-IS12ClsCmdB") { field(DESC, "CM18-19 RF SSA (FAC-IS12) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/336 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2000:StpFAC-IS13ClsCmdB") { field(DESC, "CM20-21 RF SSA (FAC-IS13) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/336 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L2B:1400:StpFAC-IS10IsOffB") { field(DESC, "LI04-LI05 CM14-15 RF SSA (FAC-IS10) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/337 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:1600:StpFAC-IS11IsOffB") { field(DESC, "LI04-LI05 CM16-17 RF SSA (FAC-IS11) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/337 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:1800:StpFAC-IS12IsOffB") { field(DESC, "LI04-LI05 CM18-19 RF SSA (FAC-IS12) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/337 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2000:StpFAC-IS13IsOffB") { field(DESC, "LI04-LI05 CM20-21 RF SSA (FAC-IS13) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/337 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI06:1:ClosedB") { field(DESC, "RT-IN S6 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:HatchB") { field(DESC, "RT-IN S6 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:EExitB") { field(DESC, "RT-IN S6 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:2:ClosedB") { field(DESC, "RT-IN S6 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=3") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:ClosedB") { field(DESC, "RT-IN S7 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:HatchB") { field(DESC, "RT-IN S7 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:EExitB") { field(DESC, "RT-IN S7 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:2:ClosedB") { field(DESC, "RT-IN S7 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/382 T=BYTE B=7") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:GateB") { field(DESC, "RT-IN LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EExitB") { field(DESC, "RT-IN LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwEOStringB") { field(DESC, "RT-IN S6 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwEOStringB") { field(DESC, "RT-IN S7 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOStringB") { field(DESC, "RT-IN S6 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EOStringB") { field(DESC, "RT-IN S7 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresetB") { field(DESC, "RT-IN S6 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI06:2:PresetB") { field(DESC, "RT-IN S6 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/383 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:1:PresetB") { field(DESC, "RT-IN S7 MW Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/384 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI07:2:PresetB") { field(DESC, "RT-IN S7 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/384 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI08:2:SearchResetB") { field(DESC, "RT-IN LI08-10ADIT Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/384 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:OFAULTB") { field(DESC, "Pilz_2B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/385 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:IFAULTB") { field(DESC, "Pilz_2B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/385 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:FAULTB") { field(DESC, "Pilz_2B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/385 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:2:DIAGB") { field(DESC, "Pilz_2B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/385 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:RUNB") { field(DESC, "Pilz_2B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/385 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:COMMB") { field(DESC, "Pilz_2B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/385 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:ClosedLatchB") { field(DESC, "LAT S6 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:HatchLatchB") { field(DESC, "LAT S6 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:1:EExitLatchB") { field(DESC, "LAT S6 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI06:2:ClosedLatchB") { field(DESC, "LAT S6 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:ClosedLatchB") { field(DESC, "LAT S7 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:HatchLatchB") { field(DESC, "LAT S7 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:1:EExitLatchB") { field(DESC, "LAT S7 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI07:2:ClosedLatchB") { field(DESC, "LAT S7 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/390 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:GateLatchB") { field(DESC, "LAT LI07/08 Housg Bndry Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/391 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EExitLatchB") { field(DESC, "LAT LI07/08 Housg Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/391 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:MwEOStringLatchB") { field(DESC, "LAT S6 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/391 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:MwEOStringLatchB") { field(DESC, "LAT S7 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/391 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOStringLatchB") { field(DESC, "LAT S6 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/391 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:EOStringLatchB") { field(DESC, "LAT S7 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/391 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:SearchResetOutB") { field(DESC, "RT-OUT LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/394 T=BYTE B=4") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresetSetB") { field(DESC, "S6 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/394 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:2:PresetSetB") { field(DESC, "S6 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/394 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresSearchB") { field(DESC, "S6 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/394 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:PresSearchTimerB") { field(DESC, "S6 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI07:1:PresetSetB") { field(DESC, "S7 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:2:PresetSetB") { field(DESC, "S7 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresSearchB") { field(DESC, "S7 MW/AOR Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI07:1:PresSearchTimerB") { field(DESC, "S7 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=4") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI06:2:Li04SafeLinkComOkB") { field(DESC, "LI06-07 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:CommHeartbeatB") { field(DESC, "LI06-07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneIntactB") { field(DESC, "LI06-07 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/395 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:2:Li04SafeLinkComOkLatchB") { field(DESC, "LAT LI06-07 SafeLink Communication OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/396 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneNoAccessB") { field(DESC, "LI06-07 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/396 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:ZoneInterlockB") { field(DESC, "LI06-07 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/396 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:EOSumyLatchB") { field(DESC, "LI06-07 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/396 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:OFAULTB") { field(DESC, "Pilz_3B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/443 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:IFAULTB") { field(DESC, "Pilz_3B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/443 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:FAULTB") { field(DESC, "Pilz_3B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/443 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI06:3:DIAGB") { field(DESC, "Pilz_3B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/443 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:RUNB") { field(DESC, "Pilz_3B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/443 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:COMMB") { field(DESC, "Pilz_3B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/443 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:PlcHeartbeatB") { field(DESC, "LI06-LI07 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/450 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI06:3:CommHeartbeatB") { field(DESC, "LI06-LI07 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/450 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI06:1:SumyB") { field(DESC, "LI06-LI07 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/450 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI06:1:StpPermitB") { field(DESC, "LI06 RF SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/451 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI06:1:XInterlockInB") { field(DESC, "LI06-LI07 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/451 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI06:1:EnableB") { field(DESC, "LI06-LI07 RF Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/451 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2200:StpFAC-IS14ClsCmdB") { field(DESC, "CM22-23 RF SSA (FAC-IS14) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2400:StpFAC-IS15ClsCmdB") { field(DESC, "CM24-25 RF SSA (FAC-IS15) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2600:StpFAC-IS16ClsCmdB") { field(DESC, "CM26-27 RF SSA (FAC-IS16) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2800:StpFAC-IS17ClsCmdB") { field(DESC, "CM28-29 RF SSA (FAC-IS17) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=3") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3000:StpFAC-IS18ClsCmdB") { field(DESC, "CM30-31 RF SSA (FAC-IS18) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=4") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3200:StpFAC-IS19ClsCmdB") { field(DESC, "CM32-33 RF SSA (FAC-IS19) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=5") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:3400:StpFAC-IS20ClsCmdB") { field(DESC, "CM34-35 RF SSA (FAC-IS20) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/452 T=BYTE B=6") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L3B:2200:StpFAC-IS14IsOffB") { field(DESC, "LI06-LI07 CM22-23 RF SSA (FAC-IS14) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2400:StpFAC-IS15IsOffB") { field(DESC, "LI06-LI07 CM24-25 RF SSA (FAC-IS15) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2600:StpFAC-IS16IsOffB") { field(DESC, "LI06-LI07 CM26-27 RF SSA (FAC-IS16) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:2800:StpFAC-IS17IsOffB") { field(DESC, "LI06-LI07 CM28-29 RF SSA (FAC-IS17) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=3") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3000:StpFAC-IS18IsOffB") { field(DESC, "LI06-LI07 CM30-31 RF SSA (FAC-IS18) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=4") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3200:StpFAC-IS19IsOffB") { field(DESC, "LI06-LI07 CM32-33 RF SSA (FAC-IS19) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=5") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L3B:3400:StpFAC-IS20IsOffB") { field(DESC, "LI06-LI07 CM34-35 RF SSA (FAC-IS20) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/453 T=BYTE B=6") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI01:1:SafetyMode") { field(DESC, "AC_PLC Safety Mode. 1 = Deactivated") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/31 T=BYTE B=0") field(ZNAM, "Activated") field(ONAM, "Deactivated") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(longin, "PLC:LI01:1:SAFETY_SIG") { field(DESC, "Safety_Signature") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/20 T=DWORD") } record(longin, "PLC:LI01:2A:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2A_Int_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/24 T=WORD") } record(longin, "PLC:LI01:2B:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2B_Int_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/28 T=WORD") } record(longin, "PLC:LI01:1:COMPILE_DT_YEAR") { field(DESC, "Compile_Yr") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/32 T=BYTE") } record(longin, "PLC:LI01:1:COMPILE_DT_MONTH") { field(DESC, "Compile_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/33 T=BYTE") } record(longin, "PLC:LI01:1:COMPILE_DT_DAY") { field(DESC, "Compile_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/34 T=BYTE") } record(longin, "PLC:LI01:1:COMPILE_DT_HOUR") { field(DESC, "Compile_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/35 T=BYTE") } record(longin, "PLC:LI01:1:COMPILE_DT_MINUTE") { field(DESC, "Compile_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/36 T=BYTE") } record(longin, "PLC:LI01:1:COMPILE_DT_SECOND") { field(DESC, "Compile_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/37 T=BYTE") } record(longin, "PLC:LI01:1:OB100_DT_YEAR") { field(DESC, "Warm_Restart_Year") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/38 T=BYTE") } record(longin, "PLC:LI01:1:OB100_DT_MONTH") { field(DESC, "Warm_Restart_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/39 T=BYTE") } record(longin, "PLC:LI01:1:OB100_DT_DAY") { field(DESC, "Warm_Restart_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/40 T=BYTE") } record(longin, "PLC:LI01:1:OB100_DT_HOUR") { field(DESC, "Warm_Restart_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/41 T=BYTE") } record(longin, "PLC:LI01:1:OB100_DT_MINUTE") { field(DESC, "Warm_Restart_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/42 T=BYTE") } record(longin, "PLC:LI01:1:OB100_DT_SECOND") { field(DESC, "Warm_Restart_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/43 T=BYTE") } record(longin, "PLC:LI01:2A:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2A_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/44 T=WORD") } record(longin, "PLC:LI01:2B:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2B_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/46 T=WORD") } record(longin, "PLC:LI01:3A:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3A_Stop_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/158 T=WORD") } record(longin, "PLC:LI01:3B:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3B_Stop_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/162 T=WORD") } record(longin, "PLC:LI01:3A:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3A_Stop_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/166 T=WORD") } record(longin, "PLC:LI01:3B:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3B_Stop_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI01_PP01/168 T=WORD") } record(calc, "DOOR:LI01:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI01:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI01:1:Closed MS") field(INPB, "DOOR:LI01:1:Locked MS") } record(mbbi, "DOOR:LI01:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI01:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI02:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI02:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI02:1:Closed MS") field(INPB, "DOOR:LI02:1:Locked MS") } record(mbbi, "DOOR:LI02:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI02:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI03:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI03:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI03:1:Closed MS") field(INPB, "DOOR:LI03:1:Locked MS") } record(mbbi, "DOOR:LI03:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI03:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI04:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI04:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI04:1:Closed MS") field(INPB, "DOOR:LI04:1:Locked MS") } record(mbbi, "DOOR:LI04:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI04:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI05:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI05:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI05:1:Closed MS") field(INPB, "DOOR:LI05:1:Locked MS") } record(mbbi, "DOOR:LI05:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI05:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI06:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI06:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI06:1:Closed MS") field(INPB, "DOOR:LI06:1:Locked MS") } record(mbbi, "DOOR:LI06:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI06:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI07:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI07:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI07:1:Closed MS") field(INPB, "DOOR:LI07:1:Locked MS") } record(mbbi, "DOOR:LI07:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI07:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "PPS:LI07:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "PPS:LI07:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "PPS:LI07:1:Gate MS") field(INPB, "PPS:LI07:1:Locked MS") } record(mbbi, "PPS:LI07:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "PPS:LI07:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(mbbi, "PPS:LI01:1:SumAccess") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(INP, "PPS:LI01:1:CalcSumAccess MS") field(ZRST, "Undefined") field(ONST, "No") field(TWST, "Restricted") field(THST, "Controlled") field(FRST, "Permitted") field(ZRSV, "MAJOR") field(ONSV, "NO_ALARM") field(TWSV, "MINOR") field(THSV, "MAJOR") field(FRSV, "MAJOR") } record(calc, "PPS:LI01:1:CalcSumAccess") { field(SCAN, "1 second") field(FLNK, "PPS:LI01:1:SumAccess") field(CALC, "A&&!B&&!C&&!D?1:!A&&B&&!C&&!D?2:!A&&!B&&C&&!D?3:!A&&!B&&!C&&D?4:0") field(INPA, "PPS:LI01:1:NoAccess MS") field(INPB, "PPS:LI01:1:RestAccess MS") field(INPC, "PPS:LI01:1:CtrlAccess MS") field(INPD, "PPS:LI01:1:PermAccess MS") }