#! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi7") { field(DESC, "Port GUNB_BSOIC_Rd bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 7, 1, 1)") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(FLNK, "BSOC:GUNB:1:HwEn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi7Valid") { field(INPA, "PLC:GUNB:PP02:Bi7.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:HwEn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:HwEn_calc") { field(INPA, "PLC:GUNB:PP02:Bi7 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi7Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:HwEn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:HwEn") { field(DESC, "BSOIC-HW_Enable") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb7",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb7") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb7.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb7.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb7.FLNK","BSOC:GUNB:1:HwEn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb7.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb7.VAL") #! Record("BSOC:GUNB:1:HwEn_calc",260,18,0,1,"BSOC:GUNB:1:HwEn_calc") #! Field("BSOC:GUNB:1:HwEn_calc.INPA",16777215,0,"BSOC:GUNB:1:HwEn_calc.INPA") #! Link("BSOC:GUNB:1:HwEn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb7.VAL") #! Field("BSOC:GUNB:1:HwEn_calc.INPB",16777215,1,"BSOC:GUNB:1:HwEn_calc.INPB") #! Field("BSOC:GUNB:1:HwEn_calc.OUT",16777215,1,"BSOC:GUNB:1:HwEn_calc.OUT") #! Link("BSOC:GUNB:1:HwEn_calc.OUT","BSOC:GUNB:1:HwEn.VAL") #! Record("BSOC:GUNB:1:HwEn",500,20,0,0,"BSOC:GUNB:1:HwEn") #! Field("BSOC:GUNB:1:HwEn.VAL",16777215,1,"BSOC:GUNB:1:HwEn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi6") { field(DESC, "Port GUNB_BSOIC_Rd bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:GUNB:1:HwResetAll_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi6Valid") { field(INPA, "PLC:GUNB:PP02:Bi6.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:HwResetAll_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:HwResetAll_calc") { field(INPA, "PLC:GUNB:PP02:Bi6 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi6Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:HwResetAll PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:HwResetAll") { field(DESC, "BSOIC-HW_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb6",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb6") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb6.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb6.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb6.FLNK","BSOC:GUNB:1:HwResetAll_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb6.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb6.VAL") #! Record("BSOC:GUNB:1:HwResetAll_calc",260,18,0,1,"BSOC:GUNB:1:HwResetAll_calc") #! Field("BSOC:GUNB:1:HwResetAll_calc.INPA",16777215,0,"BSOC:GUNB:1:HwResetAll_calc.INPA") #! Link("BSOC:GUNB:1:HwResetAll_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb6.VAL") #! Field("BSOC:GUNB:1:HwResetAll_calc.INPB",16777215,1,"BSOC:GUNB:1:HwResetAll_calc.INPB") #! Field("BSOC:GUNB:1:HwResetAll_calc.OUT",16777215,1,"BSOC:GUNB:1:HwResetAll_calc.OUT") #! Link("BSOC:GUNB:1:HwResetAll_calc.OUT","BSOC:GUNB:1:HwResetAll.VAL") #! Record("BSOC:GUNB:1:HwResetAll",500,20,0,0,"BSOC:GUNB:1:HwResetAll") #! Field("BSOC:GUNB:1:HwResetAll.VAL",16777215,1,"BSOC:GUNB:1:HwResetAll.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi5") { field(DESC, "Port GUNB_BSOIC_Rd bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 5, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:03:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi5Valid") { field(INPA, "PLC:GUNB:PP02:Bi5.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:Eqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi5 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi5Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:Eqp") { field(DESC, "BSOIC-RT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb5",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb5") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb5.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb5.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb5.FLNK","BSOC:GUNB:03:Eqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb5.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb5.VAL") #! Record("BSOC:GUNB:03:Eqp_calc",260,18,0,1,"BSOC:GUNB:03:Eqp_calc") #! Field("BSOC:GUNB:03:Eqp_calc.INPA",16777215,0,"BSOC:GUNB:03:Eqp_calc.INPA") #! Link("BSOC:GUNB:03:Eqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb5.VAL") #! Field("BSOC:GUNB:03:Eqp_calc.INPB",16777215,1,"BSOC:GUNB:03:Eqp_calc.INPB") #! Field("BSOC:GUNB:03:Eqp_calc.OUT",16777215,1,"BSOC:GUNB:03:Eqp_calc.OUT") #! Link("BSOC:GUNB:03:Eqp_calc.OUT","BSOC:GUNB:03:Eqp.VAL") #! Record("BSOC:GUNB:03:Eqp",500,20,0,0,"BSOC:GUNB:03:Eqp") #! Field("BSOC:GUNB:03:Eqp.VAL",16777215,1,"BSOC:GUNB:03:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi4") { field(DESC, "Port GUNB_BSOIC_Rd bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 4, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:03:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi4Valid") { field(INPA, "PLC:GUNB:PP02:Bi4.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:Rad_calc") { field(INPA, "PLC:GUNB:PP02:Bi4 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi4Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:Rad") { field(DESC, "BSOIC-RT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb4",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb4") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb4.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb4.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb4.FLNK","BSOC:GUNB:03:Rad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb4.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb4.VAL") #! Record("BSOC:GUNB:03:Rad_calc",260,18,0,1,"BSOC:GUNB:03:Rad_calc") #! Field("BSOC:GUNB:03:Rad_calc.INPA",16777215,0,"BSOC:GUNB:03:Rad_calc.INPA") #! Link("BSOC:GUNB:03:Rad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb4.VAL") #! Field("BSOC:GUNB:03:Rad_calc.INPB",16777215,1,"BSOC:GUNB:03:Rad_calc.INPB") #! Field("BSOC:GUNB:03:Rad_calc.OUT",16777215,1,"BSOC:GUNB:03:Rad_calc.OUT") #! Link("BSOC:GUNB:03:Rad_calc.OUT","BSOC:GUNB:03:Rad.VAL") #! Record("BSOC:GUNB:03:Rad",500,20,0,0,"BSOC:GUNB:03:Rad") #! Field("BSOC:GUNB:03:Rad.VAL",16777215,1,"BSOC:GUNB:03:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi3") { field(DESC, "Port GUNB_BSOIC_Rd bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:GUNB:03:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi3Valid") { field(INPA, "PLC:GUNB:PP02:Bi3.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:HWBypass_calc") { field(INPA, "PLC:GUNB:PP02:Bi3 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi3Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:HWBypass") { field(DESC, "BSOIC-RT_G1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb3",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb3") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb3.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb3.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb3.FLNK","BSOC:GUNB:03:HWBypass_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb3.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb3.VAL") #! Record("BSOC:GUNB:03:HWBypass_calc",260,18,0,1,"BSOC:GUNB:03:HWBypass_calc") #! Field("BSOC:GUNB:03:HWBypass_calc.INPA",16777215,0,"BSOC:GUNB:03:HWBypass_calc.INPA") #! Link("BSOC:GUNB:03:HWBypass_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb3.VAL") #! Field("BSOC:GUNB:03:HWBypass_calc.INPB",16777215,1,"BSOC:GUNB:03:HWBypass_calc.INPB") #! Field("BSOC:GUNB:03:HWBypass_calc.OUT",16777215,1,"BSOC:GUNB:03:HWBypass_calc.OUT") #! Link("BSOC:GUNB:03:HWBypass_calc.OUT","BSOC:GUNB:03:HWBypass.VAL") #! Record("BSOC:GUNB:03:HWBypass",500,20,0,0,"BSOC:GUNB:03:HWBypass") #! Field("BSOC:GUNB:03:HWBypass.VAL",16777215,1,"BSOC:GUNB:03:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi2") { field(DESC, "Port GUNB_BSOIC_Rd bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 2, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G2:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi2Valid") { field(INPA, "PLC:GUNB:PP02:Bi2.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:Eqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi2 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi2Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:Eqp") { field(DESC, "BSOIC-RT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb2",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb2") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb2.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb2.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb2.FLNK","BSOC:GUNB:G2:Eqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb2.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb2.VAL") #! Record("BSOC:GUNB:G2:Eqp_calc",260,18,0,1,"BSOC:GUNB:G2:Eqp_calc") #! Field("BSOC:GUNB:G2:Eqp_calc.INPA",16777215,0,"BSOC:GUNB:G2:Eqp_calc.INPA") #! Link("BSOC:GUNB:G2:Eqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb2.VAL") #! Field("BSOC:GUNB:G2:Eqp_calc.INPB",16777215,1,"BSOC:GUNB:G2:Eqp_calc.INPB") #! Field("BSOC:GUNB:G2:Eqp_calc.OUT",16777215,1,"BSOC:GUNB:G2:Eqp_calc.OUT") #! Link("BSOC:GUNB:G2:Eqp_calc.OUT","BSOC:GUNB:G2:Eqp.VAL") #! Record("BSOC:GUNB:G2:Eqp",500,20,0,0,"BSOC:GUNB:G2:Eqp") #! Field("BSOC:GUNB:G2:Eqp.VAL",16777215,1,"BSOC:GUNB:G2:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi1") { field(DESC, "Port GUNB_BSOIC_Rd bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 1, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G2:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi1Valid") { field(INPA, "PLC:GUNB:PP02:Bi1.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:Rad_calc") { field(INPA, "PLC:GUNB:PP02:Bi1 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi1Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:Rad") { field(DESC, "BSOIC-RT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb1",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb1") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb1.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb1.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb1.FLNK","BSOC:GUNB:G2:Rad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb1.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb1.VAL") #! Record("BSOC:GUNB:G2:Rad_calc",260,18,0,1,"BSOC:GUNB:G2:Rad_calc") #! Field("BSOC:GUNB:G2:Rad_calc.INPA",16777215,0,"BSOC:GUNB:G2:Rad_calc.INPA") #! Link("BSOC:GUNB:G2:Rad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb1.VAL") #! Field("BSOC:GUNB:G2:Rad_calc.INPB",16777215,1,"BSOC:GUNB:G2:Rad_calc.INPB") #! Field("BSOC:GUNB:G2:Rad_calc.OUT",16777215,1,"BSOC:GUNB:G2:Rad_calc.OUT") #! Link("BSOC:GUNB:G2:Rad_calc.OUT","BSOC:GUNB:G2:Rad.VAL") #! Record("BSOC:GUNB:G2:Rad",500,20,0,0,"BSOC:GUNB:G2:Rad") #! Field("BSOC:GUNB:G2:Rad.VAL",16777215,1,"BSOC:GUNB:G2:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi0") { field(DESC, "Port GUNB_BSOIC_Rd bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:GUNB:G2:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi0Valid") { field(INPA, "PLC:GUNB:PP02:Bi0.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:HWBypass_calc") { field(INPA, "PLC:GUNB:PP02:Bi0 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi0Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:HWBypass") { field(DESC, "BSOIC-RT_G2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb0",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb0") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb0.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb0.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb0.FLNK","BSOC:GUNB:G2:HWBypass_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb0.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb0.VAL") #! Record("BSOC:GUNB:G2:HWBypass_calc",260,18,0,1,"BSOC:GUNB:G2:HWBypass_calc") #! Field("BSOC:GUNB:G2:HWBypass_calc.INPA",16777215,0,"BSOC:GUNB:G2:HWBypass_calc.INPA") #! Link("BSOC:GUNB:G2:HWBypass_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb0.VAL") #! Field("BSOC:GUNB:G2:HWBypass_calc.INPB",16777215,1,"BSOC:GUNB:G2:HWBypass_calc.INPB") #! Field("BSOC:GUNB:G2:HWBypass_calc.OUT",16777215,1,"BSOC:GUNB:G2:HWBypass_calc.OUT") #! Link("BSOC:GUNB:G2:HWBypass_calc.OUT","BSOC:GUNB:G2:HWBypass.VAL") #! Record("BSOC:GUNB:G2:HWBypass",500,20,0,0,"BSOC:GUNB:G2:HWBypass") #! Field("BSOC:GUNB:G2:HWBypass.VAL",16777215,1,"BSOC:GUNB:G2:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi15") { field(DESC, "Port GUNB_BSOIC_Rd bit 15") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 15, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G3:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi15Valid") { field(INPA, "PLC:GUNB:PP02:Bi15.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:Eqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi15 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi15Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:Eqp") { field(DESC, "BSOIC-RT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb15",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb15") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb15.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb15.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb15.FLNK","BSOC:GUNB:G3:Eqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb15.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb15.VAL") #! Record("BSOC:GUNB:G3:Eqp_calc",260,18,0,1,"BSOC:GUNB:G3:Eqp_calc") #! Field("BSOC:GUNB:G3:Eqp_calc.INPA",16777215,0,"BSOC:GUNB:G3:Eqp_calc.INPA") #! Link("BSOC:GUNB:G3:Eqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb15.VAL") #! Field("BSOC:GUNB:G3:Eqp_calc.INPB",16777215,1,"BSOC:GUNB:G3:Eqp_calc.INPB") #! Field("BSOC:GUNB:G3:Eqp_calc.OUT",16777215,1,"BSOC:GUNB:G3:Eqp_calc.OUT") #! Link("BSOC:GUNB:G3:Eqp_calc.OUT","BSOC:GUNB:G3:Eqp.VAL") #! Record("BSOC:GUNB:G3:Eqp",500,20,0,0,"BSOC:GUNB:G3:Eqp") #! Field("BSOC:GUNB:G3:Eqp.VAL",16777215,1,"BSOC:GUNB:G3:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi14") { field(DESC, "Port GUNB_BSOIC_Rd bit 14") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 14, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G3:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi14Valid") { field(INPA, "PLC:GUNB:PP02:Bi14.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:Rad_calc") { field(INPA, "PLC:GUNB:PP02:Bi14 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi14Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:Rad") { field(DESC, "BSOIC-RT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb14",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb14") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb14.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb14.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb14.FLNK","BSOC:GUNB:G3:Rad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb14.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb14.VAL") #! Record("BSOC:GUNB:G3:Rad_calc",260,18,0,1,"BSOC:GUNB:G3:Rad_calc") #! Field("BSOC:GUNB:G3:Rad_calc.INPA",16777215,0,"BSOC:GUNB:G3:Rad_calc.INPA") #! Link("BSOC:GUNB:G3:Rad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb14.VAL") #! Field("BSOC:GUNB:G3:Rad_calc.INPB",16777215,1,"BSOC:GUNB:G3:Rad_calc.INPB") #! Field("BSOC:GUNB:G3:Rad_calc.OUT",16777215,1,"BSOC:GUNB:G3:Rad_calc.OUT") #! Link("BSOC:GUNB:G3:Rad_calc.OUT","BSOC:GUNB:G3:Rad.VAL") #! Record("BSOC:GUNB:G3:Rad",500,20,0,0,"BSOC:GUNB:G3:Rad") #! Field("BSOC:GUNB:G3:Rad.VAL",16777215,1,"BSOC:GUNB:G3:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi13") { field(DESC, "Port GUNB_BSOIC_Rd bit 13") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 13, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:GUNB:G3:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi13Valid") { field(INPA, "PLC:GUNB:PP02:Bi13.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:HWBypass_calc") { field(INPA, "PLC:GUNB:PP02:Bi13 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi13Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:HWBypass") { field(DESC, "BSOIC-RT_G3_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb13",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb13") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb13.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb13.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb13.FLNK","BSOC:GUNB:G3:HWBypass_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb13.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb13.VAL") #! Record("BSOC:GUNB:G3:HWBypass_calc",260,18,0,1,"BSOC:GUNB:G3:HWBypass_calc") #! Field("BSOC:GUNB:G3:HWBypass_calc.INPA",16777215,0,"BSOC:GUNB:G3:HWBypass_calc.INPA") #! Link("BSOC:GUNB:G3:HWBypass_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb13.VAL") #! Field("BSOC:GUNB:G3:HWBypass_calc.INPB",16777215,1,"BSOC:GUNB:G3:HWBypass_calc.INPB") #! Field("BSOC:GUNB:G3:HWBypass_calc.OUT",16777215,1,"BSOC:GUNB:G3:HWBypass_calc.OUT") #! Link("BSOC:GUNB:G3:HWBypass_calc.OUT","BSOC:GUNB:G3:HWBypass.VAL") #! Record("BSOC:GUNB:G3:HWBypass",500,20,0,0,"BSOC:GUNB:G3:HWBypass") #! Field("BSOC:GUNB:G3:HWBypass.VAL",16777215,1,"BSOC:GUNB:G3:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi12") { field(DESC, "Port GUNB_BSOIC_Rd bit 12") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 12, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G4:Eqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi12Valid") { field(INPA, "PLC:GUNB:PP02:Bi12.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:Eqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:Eqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi12 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi12Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:Eqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:Eqp") { field(DESC, "BSOIC-RT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb12",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb12") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb12.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb12.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb12.FLNK","BSOC:GUNB:G4:Eqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb12.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb12.VAL") #! Record("BSOC:GUNB:G4:Eqp_calc",260,18,0,1,"BSOC:GUNB:G4:Eqp_calc") #! Field("BSOC:GUNB:G4:Eqp_calc.INPA",16777215,0,"BSOC:GUNB:G4:Eqp_calc.INPA") #! Link("BSOC:GUNB:G4:Eqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb12.VAL") #! Field("BSOC:GUNB:G4:Eqp_calc.INPB",16777215,1,"BSOC:GUNB:G4:Eqp_calc.INPB") #! Field("BSOC:GUNB:G4:Eqp_calc.OUT",16777215,1,"BSOC:GUNB:G4:Eqp_calc.OUT") #! Link("BSOC:GUNB:G4:Eqp_calc.OUT","BSOC:GUNB:G4:Eqp.VAL") #! Record("BSOC:GUNB:G4:Eqp",500,20,0,0,"BSOC:GUNB:G4:Eqp") #! Field("BSOC:GUNB:G4:Eqp.VAL",16777215,1,"BSOC:GUNB:G4:Eqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi11") { field(DESC, "Port GUNB_BSOIC_Rd bit 11") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 11, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G4:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi11Valid") { field(INPA, "PLC:GUNB:PP02:Bi11.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:Rad_calc") { field(INPA, "PLC:GUNB:PP02:Bi11 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi11Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:Rad") { field(DESC, "BSOIC-RT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb11",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb11") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb11.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb11.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb11.FLNK","BSOC:GUNB:G4:Rad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb11.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb11.VAL") #! Record("BSOC:GUNB:G4:Rad_calc",260,18,0,1,"BSOC:GUNB:G4:Rad_calc") #! Field("BSOC:GUNB:G4:Rad_calc.INPA",16777215,0,"BSOC:GUNB:G4:Rad_calc.INPA") #! Link("BSOC:GUNB:G4:Rad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb11.VAL") #! Field("BSOC:GUNB:G4:Rad_calc.INPB",16777215,1,"BSOC:GUNB:G4:Rad_calc.INPB") #! Field("BSOC:GUNB:G4:Rad_calc.OUT",16777215,1,"BSOC:GUNB:G4:Rad_calc.OUT") #! Link("BSOC:GUNB:G4:Rad_calc.OUT","BSOC:GUNB:G4:Rad.VAL") #! Record("BSOC:GUNB:G4:Rad",500,20,0,0,"BSOC:GUNB:G4:Rad") #! Field("BSOC:GUNB:G4:Rad.VAL",16777215,1,"BSOC:GUNB:G4:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi10") { field(DESC, "Port GUNB_BSOIC_Rd bit 10") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 10, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:GUNB:G4:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi10Valid") { field(INPA, "PLC:GUNB:PP02:Bi10.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:HWBypass_calc") { field(INPA, "PLC:GUNB:PP02:Bi10 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi10Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:HWBypass") { field(DESC, "BSOIC-RT_G4_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb10",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb10") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb10.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb10.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb10.FLNK","BSOC:GUNB:G4:HWBypass_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb10.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb10.VAL") #! Record("BSOC:GUNB:G4:HWBypass_calc",260,18,0,1,"BSOC:GUNB:G4:HWBypass_calc") #! Field("BSOC:GUNB:G4:HWBypass_calc.INPA",16777215,0,"BSOC:GUNB:G4:HWBypass_calc.INPA") #! Link("BSOC:GUNB:G4:HWBypass_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb10.VAL") #! Field("BSOC:GUNB:G4:HWBypass_calc.INPB",16777215,1,"BSOC:GUNB:G4:HWBypass_calc.INPB") #! Field("BSOC:GUNB:G4:HWBypass_calc.OUT",16777215,1,"BSOC:GUNB:G4:HWBypass_calc.OUT") #! Link("BSOC:GUNB:G4:HWBypass_calc.OUT","BSOC:GUNB:G4:HWBypass.VAL") #! Record("BSOC:GUNB:G4:HWBypass",500,20,0,0,"BSOC:GUNB:G4:HWBypass") #! Field("BSOC:GUNB:G4:HWBypass.VAL",16777215,1,"BSOC:GUNB:G4:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi9") { field(DESC, "Port GUNB_BSOIC_Rd bit 9") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 9, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:04N:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi9Valid") { field(INPA, "PLC:GUNB:PP02:Bi9.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:04N:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:04N:Rad_calc") { field(INPA, "PLC:GUNB:PP02:Bi9 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi9Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:04N:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:04N:Rad") { field(DESC, "BSOIC-RT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb9",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb9") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb9.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb9.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb9.FLNK","BSOC:GUNB:04N:Rad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb9.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb9.VAL") #! Record("BSOC:GUNB:04N:Rad_calc",260,18,0,1,"BSOC:GUNB:04N:Rad_calc") #! Field("BSOC:GUNB:04N:Rad_calc.INPA",16777215,0,"BSOC:GUNB:04N:Rad_calc.INPA") #! Link("BSOC:GUNB:04N:Rad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb9.VAL") #! Field("BSOC:GUNB:04N:Rad_calc.INPB",16777215,1,"BSOC:GUNB:04N:Rad_calc.INPB") #! Field("BSOC:GUNB:04N:Rad_calc.OUT",16777215,1,"BSOC:GUNB:04N:Rad_calc.OUT") #! Link("BSOC:GUNB:04N:Rad_calc.OUT","BSOC:GUNB:04N:Rad.VAL") #! Record("BSOC:GUNB:04N:Rad",500,20,0,0,"BSOC:GUNB:04N:Rad") #! Field("BSOC:GUNB:04N:Rad.VAL",16777215,1,"BSOC:GUNB:04N:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi8") { field(DESC, "Port GUNB_BSOIC_Rd bit 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 8, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:GUNB:04N:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi8Valid") { field(INPA, "PLC:GUNB:PP02:Bi8.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:04N:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:04N:HWBypass_calc") { field(INPA, "PLC:GUNB:PP02:Bi8 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi8Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:04N:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:04N:HWBypass") { field(DESC, "BSOIC-RT_N1_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb8",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb8") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb8.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb8.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb8.FLNK","BSOC:GUNB:04N:HWBypass_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb8.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb8.VAL") #! Record("BSOC:GUNB:04N:HWBypass_calc",260,18,0,1,"BSOC:GUNB:04N:HWBypass_calc") #! Field("BSOC:GUNB:04N:HWBypass_calc.INPA",16777215,0,"BSOC:GUNB:04N:HWBypass_calc.INPA") #! Link("BSOC:GUNB:04N:HWBypass_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb8.VAL") #! Field("BSOC:GUNB:04N:HWBypass_calc.INPB",16777215,1,"BSOC:GUNB:04N:HWBypass_calc.INPB") #! Field("BSOC:GUNB:04N:HWBypass_calc.OUT",16777215,1,"BSOC:GUNB:04N:HWBypass_calc.OUT") #! Link("BSOC:GUNB:04N:HWBypass_calc.OUT","BSOC:GUNB:04N:HWBypass.VAL") #! Record("BSOC:GUNB:04N:HWBypass",500,20,0,0,"BSOC:GUNB:04N:HWBypass") #! Field("BSOC:GUNB:04N:HWBypass.VAL",16777215,1,"BSOC:GUNB:04N:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi23") { field(DESC, "Port GUNB_BSOIC_Rd bit 23") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 23, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:N2:Rad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi23Valid") { field(INPA, "PLC:GUNB:PP02:Bi23.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:N2:Rad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:N2:Rad_calc") { field(INPA, "PLC:GUNB:PP02:Bi23 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi23Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:N2:Rad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:N2:Rad") { field(DESC, "BSOIC-RT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb23",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb23") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb23.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb23.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb23.FLNK","BSOC:GUNB:N2:Rad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb23.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb23.VAL") #! Record("BSOC:GUNB:N2:Rad_calc",260,18,0,1,"BSOC:GUNB:N2:Rad_calc") #! Field("BSOC:GUNB:N2:Rad_calc.INPA",16777215,0,"BSOC:GUNB:N2:Rad_calc.INPA") #! Link("BSOC:GUNB:N2:Rad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb23.VAL") #! Field("BSOC:GUNB:N2:Rad_calc.INPB",16777215,1,"BSOC:GUNB:N2:Rad_calc.INPB") #! Field("BSOC:GUNB:N2:Rad_calc.OUT",16777215,1,"BSOC:GUNB:N2:Rad_calc.OUT") #! Link("BSOC:GUNB:N2:Rad_calc.OUT","BSOC:GUNB:N2:Rad.VAL") #! Record("BSOC:GUNB:N2:Rad",500,20,0,0,"BSOC:GUNB:N2:Rad") #! Field("BSOC:GUNB:N2:Rad.VAL",16777215,1,"BSOC:GUNB:N2:Rad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi22") { field(DESC, "Port GUNB_BSOIC_Rd bit 22") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 22, 1, 1)") field(ZNAM, "Off") field(ONAM, "Bypassed") field(FLNK, "BSOC:GUNB:N2:HWBypass_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi22Valid") { field(INPA, "PLC:GUNB:PP02:Bi22.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:N2:HWBypass_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:N2:HWBypass_calc") { field(INPA, "PLC:GUNB:PP02:Bi22 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi22Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:N2:HWBypass PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:N2:HWBypass") { field(DESC, "BSOIC-RT_N2_HW_Bypass") field(ZNAM, "Off") field(ONAM, "Bypassed") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb22",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb22") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb22.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb22.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb22.FLNK","BSOC:GUNB:N2:HWBypass_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb22.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb22.VAL") #! Record("BSOC:GUNB:N2:HWBypass_calc",260,18,0,1,"BSOC:GUNB:N2:HWBypass_calc") #! Field("BSOC:GUNB:N2:HWBypass_calc.INPA",16777215,0,"BSOC:GUNB:N2:HWBypass_calc.INPA") #! Link("BSOC:GUNB:N2:HWBypass_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb22.VAL") #! Field("BSOC:GUNB:N2:HWBypass_calc.INPB",16777215,1,"BSOC:GUNB:N2:HWBypass_calc.INPB") #! Field("BSOC:GUNB:N2:HWBypass_calc.OUT",16777215,1,"BSOC:GUNB:N2:HWBypass_calc.OUT") #! Link("BSOC:GUNB:N2:HWBypass_calc.OUT","BSOC:GUNB:N2:HWBypass.VAL") #! Record("BSOC:GUNB:N2:HWBypass",500,20,0,0,"BSOC:GUNB:N2:HWBypass") #! Field("BSOC:GUNB:N2:HWBypass.VAL",16777215,1,"BSOC:GUNB:N2:HWBypass.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi21") { field(DESC, "Port GUNB_BSOIC_Rd bit 21") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 21, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi21Valid") { field(INPA, "PLC:GUNB:PP02:Bi21.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:CascIn_calc") { field(INPA, "PLC:GUNB:PP02:Bi21 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi21Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb21",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb21") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb21.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb21.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb21.FLNK","BSOC:GUNB:1:CascIn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb21.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb21.VAL") #! Record("BSOC:GUNB:1:CascIn_calc",260,18,0,1,"BSOC:GUNB:1:CascIn_calc") #! Field("BSOC:GUNB:1:CascIn_calc.INPA",16777215,0,"BSOC:GUNB:1:CascIn_calc.INPA") #! Link("BSOC:GUNB:1:CascIn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb21.VAL") #! Field("BSOC:GUNB:1:CascIn_calc.INPB",16777215,1,"BSOC:GUNB:1:CascIn_calc.INPB") #! Field("BSOC:GUNB:1:CascIn_calc.OUT",16777215,1,"BSOC:GUNB:1:CascIn_calc.OUT") #! Link("BSOC:GUNB:1:CascIn_calc.OUT","BSOC:GUNB:1:CascIn.VAL") #! Record("BSOC:GUNB:1:CascIn",500,20,0,0,"BSOC:GUNB:1:CascIn") #! Field("BSOC:GUNB:1:CascIn.VAL",16777215,1,"BSOC:GUNB:1:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi20") { field(DESC, "Port GUNB_BSOIC_Rd bit 20") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 20, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:2:CascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi20Valid") { field(INPA, "PLC:GUNB:PP02:Bi20.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:2:CascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:2:CascIn_calc") { field(INPA, "PLC:GUNB:PP02:Bi20 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi20Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:2:CascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:2:CascIn") { field(DESC, "BSOIC-RT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb20",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb20") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb20.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb20.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb20.FLNK","BSOC:GUNB:2:CascIn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb20.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb20.VAL") #! Record("BSOC:GUNB:2:CascIn_calc",260,18,0,1,"BSOC:GUNB:2:CascIn_calc") #! Field("BSOC:GUNB:2:CascIn_calc.INPA",16777215,0,"BSOC:GUNB:2:CascIn_calc.INPA") #! Link("BSOC:GUNB:2:CascIn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb20.VAL") #! Field("BSOC:GUNB:2:CascIn_calc.INPB",16777215,1,"BSOC:GUNB:2:CascIn_calc.INPB") #! Field("BSOC:GUNB:2:CascIn_calc.OUT",16777215,1,"BSOC:GUNB:2:CascIn_calc.OUT") #! Link("BSOC:GUNB:2:CascIn_calc.OUT","BSOC:GUNB:2:CascIn.VAL") #! Record("BSOC:GUNB:2:CascIn",500,20,0,0,"BSOC:GUNB:2:CascIn") #! Field("BSOC:GUNB:2:CascIn.VAL",16777215,1,"BSOC:GUNB:2:CascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi19") { field(DESC, "Port GUNB_BSOIC_Rd bit 19") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 19, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:GUNB:03:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi19Valid") { field(INPA, "PLC:GUNB:PP02:Bi19.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:SoRstRb_calc") { field(INPA, "PLC:GUNB:PP02:Bi19 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi19Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:SoRstRb") { field(DESC, "BSOIC-G1_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb19",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb19") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb19.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb19.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb19.FLNK","BSOC:GUNB:03:SoRstRb_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb19.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb19.VAL") #! Record("BSOC:GUNB:03:SoRstRb_calc",260,18,0,1,"BSOC:GUNB:03:SoRstRb_calc") #! Field("BSOC:GUNB:03:SoRstRb_calc.INPA",16777215,0,"BSOC:GUNB:03:SoRstRb_calc.INPA") #! Link("BSOC:GUNB:03:SoRstRb_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb19.VAL") #! Field("BSOC:GUNB:03:SoRstRb_calc.INPB",16777215,1,"BSOC:GUNB:03:SoRstRb_calc.INPB") #! Field("BSOC:GUNB:03:SoRstRb_calc.OUT",16777215,1,"BSOC:GUNB:03:SoRstRb_calc.OUT") #! Link("BSOC:GUNB:03:SoRstRb_calc.OUT","BSOC:GUNB:03:SoRstRb.VAL") #! Record("BSOC:GUNB:03:SoRstRb",500,20,0,0,"BSOC:GUNB:03:SoRstRb") #! Field("BSOC:GUNB:03:SoRstRb.VAL",16777215,1,"BSOC:GUNB:03:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi18") { field(DESC, "Port GUNB_BSOIC_Rd bit 18") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 18, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:GUNB:G2:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi18Valid") { field(INPA, "PLC:GUNB:PP02:Bi18.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:SoRstRb_calc") { field(INPA, "PLC:GUNB:PP02:Bi18 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi18Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:SoRstRb") { field(DESC, "BSOIC-G2_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb18",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb18") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb18.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb18.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb18.FLNK","BSOC:GUNB:G2:SoRstRb_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb18.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb18.VAL") #! Record("BSOC:GUNB:G2:SoRstRb_calc",260,18,0,1,"BSOC:GUNB:G2:SoRstRb_calc") #! Field("BSOC:GUNB:G2:SoRstRb_calc.INPA",16777215,0,"BSOC:GUNB:G2:SoRstRb_calc.INPA") #! Link("BSOC:GUNB:G2:SoRstRb_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb18.VAL") #! Field("BSOC:GUNB:G2:SoRstRb_calc.INPB",16777215,1,"BSOC:GUNB:G2:SoRstRb_calc.INPB") #! Field("BSOC:GUNB:G2:SoRstRb_calc.OUT",16777215,1,"BSOC:GUNB:G2:SoRstRb_calc.OUT") #! Link("BSOC:GUNB:G2:SoRstRb_calc.OUT","BSOC:GUNB:G2:SoRstRb.VAL") #! Record("BSOC:GUNB:G2:SoRstRb",500,20,0,0,"BSOC:GUNB:G2:SoRstRb") #! Field("BSOC:GUNB:G2:SoRstRb.VAL",16777215,1,"BSOC:GUNB:G2:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi17") { field(DESC, "Port GUNB_BSOIC_Rd bit 17") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 17, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:GUNB:G3:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi17Valid") { field(INPA, "PLC:GUNB:PP02:Bi17.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:SoRstRb_calc") { field(INPA, "PLC:GUNB:PP02:Bi17 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi17Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:SoRstRb") { field(DESC, "BSOIC-G3_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb17",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb17") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb17.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb17.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb17.FLNK","BSOC:GUNB:G3:SoRstRb_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb17.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb17.VAL") #! Record("BSOC:GUNB:G3:SoRstRb_calc",260,18,0,1,"BSOC:GUNB:G3:SoRstRb_calc") #! Field("BSOC:GUNB:G3:SoRstRb_calc.INPA",16777215,0,"BSOC:GUNB:G3:SoRstRb_calc.INPA") #! Link("BSOC:GUNB:G3:SoRstRb_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb17.VAL") #! Field("BSOC:GUNB:G3:SoRstRb_calc.INPB",16777215,1,"BSOC:GUNB:G3:SoRstRb_calc.INPB") #! Field("BSOC:GUNB:G3:SoRstRb_calc.OUT",16777215,1,"BSOC:GUNB:G3:SoRstRb_calc.OUT") #! Link("BSOC:GUNB:G3:SoRstRb_calc.OUT","BSOC:GUNB:G3:SoRstRb.VAL") #! Record("BSOC:GUNB:G3:SoRstRb",500,20,0,0,"BSOC:GUNB:G3:SoRstRb") #! Field("BSOC:GUNB:G3:SoRstRb.VAL",16777215,1,"BSOC:GUNB:G3:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi16") { field(DESC, "Port GUNB_BSOIC_Rd bit 16") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 16, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(FLNK, "BSOC:GUNB:G4:SoRstRb_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi16Valid") { field(INPA, "PLC:GUNB:PP02:Bi16.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:SoRstRb_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:SoRstRb_calc") { field(INPA, "PLC:GUNB:PP02:Bi16 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi16Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:SoRstRb PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:SoRstRb") { field(DESC, "BSOIC-G4_Soft_Reset") field(ZNAM, "Off") field(ONAM, "Reset") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb16",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb16") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb16.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb16.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb16.FLNK","BSOC:GUNB:G4:SoRstRb_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb16.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb16.VAL") #! Record("BSOC:GUNB:G4:SoRstRb_calc",260,18,0,1,"BSOC:GUNB:G4:SoRstRb_calc") #! Field("BSOC:GUNB:G4:SoRstRb_calc.INPA",16777215,0,"BSOC:GUNB:G4:SoRstRb_calc.INPA") #! Link("BSOC:GUNB:G4:SoRstRb_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb16.VAL") #! Field("BSOC:GUNB:G4:SoRstRb_calc.INPB",16777215,1,"BSOC:GUNB:G4:SoRstRb_calc.INPB") #! Field("BSOC:GUNB:G4:SoRstRb_calc.OUT",16777215,1,"BSOC:GUNB:G4:SoRstRb_calc.OUT") #! Link("BSOC:GUNB:G4:SoRstRb_calc.OUT","BSOC:GUNB:G4:SoRstRb.VAL") #! Record("BSOC:GUNB:G4:SoRstRb",500,20,0,0,"BSOC:GUNB:G4:SoRstRb") #! Field("BSOC:GUNB:G4:SoRstRb.VAL",16777215,1,"BSOC:GUNB:G4:SoRstRb.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi95") { field(DESC, "Port GUNB_BSOIC_Rd bit 95") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 95, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:GUNB:1:AnnAlarm_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi95Valid") { field(INPA, "PLC:GUNB:PP02:Bi95.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:AnnAlarm_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:AnnAlarm_calc") { field(INPA, "PLC:GUNB:PP02:Bi95 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi95Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:AnnAlarm PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:AnnAlarm") { field(DESC, "BSOIC-HW_Annunciator_Alarm") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb95",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb95") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb95.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb95.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb95.FLNK","BSOC:GUNB:1:AnnAlarm_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb95.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb95.VAL") #! Record("BSOC:GUNB:1:AnnAlarm_calc",260,18,0,1,"BSOC:GUNB:1:AnnAlarm_calc") #! Field("BSOC:GUNB:1:AnnAlarm_calc.INPA",16777215,0,"BSOC:GUNB:1:AnnAlarm_calc.INPA") #! Link("BSOC:GUNB:1:AnnAlarm_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb95.VAL") #! Field("BSOC:GUNB:1:AnnAlarm_calc.INPB",16777215,1,"BSOC:GUNB:1:AnnAlarm_calc.INPB") #! Field("BSOC:GUNB:1:AnnAlarm_calc.OUT",16777215,1,"BSOC:GUNB:1:AnnAlarm_calc.OUT") #! Link("BSOC:GUNB:1:AnnAlarm_calc.OUT","BSOC:GUNB:1:AnnAlarm.VAL") #! Record("BSOC:GUNB:1:AnnAlarm",500,20,0,0,"BSOC:GUNB:1:AnnAlarm") #! Field("BSOC:GUNB:1:AnnAlarm.VAL",16777215,1,"BSOC:GUNB:1:AnnAlarm.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi94") { field(DESC, "Port GUNB_BSOIC_Rd bit 94") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 94, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:GUNB:1:CascOut_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi94Valid") { field(INPA, "PLC:GUNB:PP02:Bi94.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:CascOut_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:CascOut_calc") { field(INPA, "PLC:GUNB:PP02:Bi94 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi94Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:CascOut PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:CascOut") { field(DESC, "BSOIC-HW_Cascade_Out") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb94",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb94") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb94.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb94.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb94.FLNK","BSOC:GUNB:1:CascOut_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb94.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb94.VAL") #! Record("BSOC:GUNB:1:CascOut_calc",260,18,0,1,"BSOC:GUNB:1:CascOut_calc") #! Field("BSOC:GUNB:1:CascOut_calc.INPA",16777215,0,"BSOC:GUNB:1:CascOut_calc.INPA") #! Link("BSOC:GUNB:1:CascOut_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb94.VAL") #! Field("BSOC:GUNB:1:CascOut_calc.INPB",16777215,1,"BSOC:GUNB:1:CascOut_calc.INPB") #! Field("BSOC:GUNB:1:CascOut_calc.OUT",16777215,1,"BSOC:GUNB:1:CascOut_calc.OUT") #! Link("BSOC:GUNB:1:CascOut_calc.OUT","BSOC:GUNB:1:CascOut.VAL") #! Record("BSOC:GUNB:1:CascOut",500,20,0,0,"BSOC:GUNB:1:CascOut") #! Field("BSOC:GUNB:1:CascOut.VAL",16777215,1,"BSOC:GUNB:1:CascOut.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi93") { field(DESC, "Port GUNB_BSOIC_Rd bit 93") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 93, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:HWSfOut1_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi93Valid") { field(INPA, "PLC:GUNB:PP02:Bi93.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:HWSfOut1_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:HWSfOut1_calc") { field(INPA, "PLC:GUNB:PP02:Bi93 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi93Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:HWSfOut1 PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:HWSfOut1") { field(DESC, "BSOIC-HW_Safety_Out1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb93",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb93") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb93.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb93.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb93.FLNK","BSOC:GUNB:1:HWSfOut1_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb93.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb93.VAL") #! Record("BSOC:GUNB:1:HWSfOut1_calc",260,18,0,1,"BSOC:GUNB:1:HWSfOut1_calc") #! Field("BSOC:GUNB:1:HWSfOut1_calc.INPA",16777215,0,"BSOC:GUNB:1:HWSfOut1_calc.INPA") #! Link("BSOC:GUNB:1:HWSfOut1_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb93.VAL") #! Field("BSOC:GUNB:1:HWSfOut1_calc.INPB",16777215,1,"BSOC:GUNB:1:HWSfOut1_calc.INPB") #! Field("BSOC:GUNB:1:HWSfOut1_calc.OUT",16777215,1,"BSOC:GUNB:1:HWSfOut1_calc.OUT") #! Link("BSOC:GUNB:1:HWSfOut1_calc.OUT","BSOC:GUNB:1:HWSfOut1.VAL") #! Record("BSOC:GUNB:1:HWSfOut1",500,20,0,0,"BSOC:GUNB:1:HWSfOut1") #! Field("BSOC:GUNB:1:HWSfOut1.VAL",16777215,1,"BSOC:GUNB:1:HWSfOut1.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi92") { field(DESC, "Port GUNB_BSOIC_Rd bit 92") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 92, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:HWSfOut2_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi92Valid") { field(INPA, "PLC:GUNB:PP02:Bi92.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:HWSfOut2_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:HWSfOut2_calc") { field(INPA, "PLC:GUNB:PP02:Bi92 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi92Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:HWSfOut2 PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:HWSfOut2") { field(DESC, "BSOIC-HW_Safety_Out2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb92",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb92") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb92.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb92.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb92.FLNK","BSOC:GUNB:1:HWSfOut2_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb92.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb92.VAL") #! Record("BSOC:GUNB:1:HWSfOut2_calc",260,18,0,1,"BSOC:GUNB:1:HWSfOut2_calc") #! Field("BSOC:GUNB:1:HWSfOut2_calc.INPA",16777215,0,"BSOC:GUNB:1:HWSfOut2_calc.INPA") #! Link("BSOC:GUNB:1:HWSfOut2_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb92.VAL") #! Field("BSOC:GUNB:1:HWSfOut2_calc.INPB",16777215,1,"BSOC:GUNB:1:HWSfOut2_calc.INPB") #! Field("BSOC:GUNB:1:HWSfOut2_calc.OUT",16777215,1,"BSOC:GUNB:1:HWSfOut2_calc.OUT") #! Link("BSOC:GUNB:1:HWSfOut2_calc.OUT","BSOC:GUNB:1:HWSfOut2.VAL") #! Record("BSOC:GUNB:1:HWSfOut2",500,20,0,0,"BSOC:GUNB:1:HWSfOut2") #! Field("BSOC:GUNB:1:HWSfOut2.VAL",16777215,1,"BSOC:GUNB:1:HWSfOut2.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi91") { field(DESC, "Port GUNB_BSOIC_Rd bit 91") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 91, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:HWSfOut3_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi91Valid") { field(INPA, "PLC:GUNB:PP02:Bi91.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:HWSfOut3_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:HWSfOut3_calc") { field(INPA, "PLC:GUNB:PP02:Bi91 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi91Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:HWSfOut3 PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:HWSfOut3") { field(DESC, "BSOIC-HW_Safety_Out3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb91",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb91") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb91.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb91.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb91.FLNK","BSOC:GUNB:1:HWSfOut3_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb91.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb91.VAL") #! Record("BSOC:GUNB:1:HWSfOut3_calc",260,18,0,1,"BSOC:GUNB:1:HWSfOut3_calc") #! Field("BSOC:GUNB:1:HWSfOut3_calc.INPA",16777215,0,"BSOC:GUNB:1:HWSfOut3_calc.INPA") #! Link("BSOC:GUNB:1:HWSfOut3_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb91.VAL") #! Field("BSOC:GUNB:1:HWSfOut3_calc.INPB",16777215,1,"BSOC:GUNB:1:HWSfOut3_calc.INPB") #! Field("BSOC:GUNB:1:HWSfOut3_calc.OUT",16777215,1,"BSOC:GUNB:1:HWSfOut3_calc.OUT") #! Link("BSOC:GUNB:1:HWSfOut3_calc.OUT","BSOC:GUNB:1:HWSfOut3.VAL") #! Record("BSOC:GUNB:1:HWSfOut3",500,20,0,0,"BSOC:GUNB:1:HWSfOut3") #! Field("BSOC:GUNB:1:HWSfOut3.VAL",16777215,1,"BSOC:GUNB:1:HWSfOut3.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi90") { field(DESC, "Port GUNB_BSOIC_Rd bit 90") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 90, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:HWSfOut4_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi90Valid") { field(INPA, "PLC:GUNB:PP02:Bi90.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:HWSfOut4_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:HWSfOut4_calc") { field(INPA, "PLC:GUNB:PP02:Bi90 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi90Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:HWSfOut4 PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:HWSfOut4") { field(DESC, "BSOIC-HW_Safety_Out4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb90",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb90") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb90.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb90.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb90.FLNK","BSOC:GUNB:1:HWSfOut4_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb90.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb90.VAL") #! Record("BSOC:GUNB:1:HWSfOut4_calc",260,18,0,1,"BSOC:GUNB:1:HWSfOut4_calc") #! Field("BSOC:GUNB:1:HWSfOut4_calc.INPA",16777215,0,"BSOC:GUNB:1:HWSfOut4_calc.INPA") #! Link("BSOC:GUNB:1:HWSfOut4_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb90.VAL") #! Field("BSOC:GUNB:1:HWSfOut4_calc.INPB",16777215,1,"BSOC:GUNB:1:HWSfOut4_calc.INPB") #! Field("BSOC:GUNB:1:HWSfOut4_calc.OUT",16777215,1,"BSOC:GUNB:1:HWSfOut4_calc.OUT") #! Link("BSOC:GUNB:1:HWSfOut4_calc.OUT","BSOC:GUNB:1:HWSfOut4.VAL") #! Record("BSOC:GUNB:1:HWSfOut4",500,20,0,0,"BSOC:GUNB:1:HWSfOut4") #! Field("BSOC:GUNB:1:HWSfOut4.VAL",16777215,1,"BSOC:GUNB:1:HWSfOut4.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi89") { field(DESC, "Port GUNB_BSOIC_Rd bit 89") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 89, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:03:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi89Valid") { field(INPA, "PLC:GUNB:PP02:Bi89.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:LatEqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi89 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi89Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:LatEqp") { field(DESC, "BSOIC-LAT_G1_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb89",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb89") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb89.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb89.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb89.FLNK","BSOC:GUNB:03:LatEqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb89.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb89.VAL") #! Record("BSOC:GUNB:03:LatEqp_calc",260,18,0,1,"BSOC:GUNB:03:LatEqp_calc") #! Field("BSOC:GUNB:03:LatEqp_calc.INPA",16777215,0,"BSOC:GUNB:03:LatEqp_calc.INPA") #! Link("BSOC:GUNB:03:LatEqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb89.VAL") #! Field("BSOC:GUNB:03:LatEqp_calc.INPB",16777215,1,"BSOC:GUNB:03:LatEqp_calc.INPB") #! Field("BSOC:GUNB:03:LatEqp_calc.OUT",16777215,1,"BSOC:GUNB:03:LatEqp_calc.OUT") #! Link("BSOC:GUNB:03:LatEqp_calc.OUT","BSOC:GUNB:03:LatEqp.VAL") #! Record("BSOC:GUNB:03:LatEqp",500,20,0,0,"BSOC:GUNB:03:LatEqp") #! Field("BSOC:GUNB:03:LatEqp.VAL",16777215,1,"BSOC:GUNB:03:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi88") { field(DESC, "Port GUNB_BSOIC_Rd bit 88") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 88, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:03:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi88Valid") { field(INPA, "PLC:GUNB:PP02:Bi88.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:LatRad_calc") { field(INPA, "PLC:GUNB:PP02:Bi88 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi88Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:LatRad") { field(DESC, "BSOIC-LAT_G1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb88",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb88") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb88.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb88.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb88.FLNK","BSOC:GUNB:03:LatRad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb88.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb88.VAL") #! Record("BSOC:GUNB:03:LatRad_calc",260,18,0,1,"BSOC:GUNB:03:LatRad_calc") #! Field("BSOC:GUNB:03:LatRad_calc.INPA",16777215,0,"BSOC:GUNB:03:LatRad_calc.INPA") #! Link("BSOC:GUNB:03:LatRad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb88.VAL") #! Field("BSOC:GUNB:03:LatRad_calc.INPB",16777215,1,"BSOC:GUNB:03:LatRad_calc.INPB") #! Field("BSOC:GUNB:03:LatRad_calc.OUT",16777215,1,"BSOC:GUNB:03:LatRad_calc.OUT") #! Link("BSOC:GUNB:03:LatRad_calc.OUT","BSOC:GUNB:03:LatRad.VAL") #! Record("BSOC:GUNB:03:LatRad",500,20,0,0,"BSOC:GUNB:03:LatRad") #! Field("BSOC:GUNB:03:LatRad.VAL",16777215,1,"BSOC:GUNB:03:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi103") { field(DESC, "Port GUNB_BSOIC_Rd bit 103") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 103, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G2:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi103Valid") { field(INPA, "PLC:GUNB:PP02:Bi103.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:LatEqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi103 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi103Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:LatEqp") { field(DESC, "BSOIC-LAT_G2_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb103",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb103") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb103.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb103.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb103.FLNK","BSOC:GUNB:G2:LatEqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb103.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb103.VAL") #! Record("BSOC:GUNB:G2:LatEqp_calc",260,18,0,1,"BSOC:GUNB:G2:LatEqp_calc") #! Field("BSOC:GUNB:G2:LatEqp_calc.INPA",16777215,0,"BSOC:GUNB:G2:LatEqp_calc.INPA") #! Link("BSOC:GUNB:G2:LatEqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb103.VAL") #! Field("BSOC:GUNB:G2:LatEqp_calc.INPB",16777215,1,"BSOC:GUNB:G2:LatEqp_calc.INPB") #! Field("BSOC:GUNB:G2:LatEqp_calc.OUT",16777215,1,"BSOC:GUNB:G2:LatEqp_calc.OUT") #! Link("BSOC:GUNB:G2:LatEqp_calc.OUT","BSOC:GUNB:G2:LatEqp.VAL") #! Record("BSOC:GUNB:G2:LatEqp",500,20,0,0,"BSOC:GUNB:G2:LatEqp") #! Field("BSOC:GUNB:G2:LatEqp.VAL",16777215,1,"BSOC:GUNB:G2:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi102") { field(DESC, "Port GUNB_BSOIC_Rd bit 102") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 102, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G2:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi102Valid") { field(INPA, "PLC:GUNB:PP02:Bi102.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:LatRad_calc") { field(INPA, "PLC:GUNB:PP02:Bi102 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi102Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:LatRad") { field(DESC, "BSOIC-LAT_G2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb102",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb102") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb102.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb102.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb102.FLNK","BSOC:GUNB:G2:LatRad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb102.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb102.VAL") #! Record("BSOC:GUNB:G2:LatRad_calc",260,18,0,1,"BSOC:GUNB:G2:LatRad_calc") #! Field("BSOC:GUNB:G2:LatRad_calc.INPA",16777215,0,"BSOC:GUNB:G2:LatRad_calc.INPA") #! Link("BSOC:GUNB:G2:LatRad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb102.VAL") #! Field("BSOC:GUNB:G2:LatRad_calc.INPB",16777215,1,"BSOC:GUNB:G2:LatRad_calc.INPB") #! Field("BSOC:GUNB:G2:LatRad_calc.OUT",16777215,1,"BSOC:GUNB:G2:LatRad_calc.OUT") #! Link("BSOC:GUNB:G2:LatRad_calc.OUT","BSOC:GUNB:G2:LatRad.VAL") #! Record("BSOC:GUNB:G2:LatRad",500,20,0,0,"BSOC:GUNB:G2:LatRad") #! Field("BSOC:GUNB:G2:LatRad.VAL",16777215,1,"BSOC:GUNB:G2:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi101") { field(DESC, "Port GUNB_BSOIC_Rd bit 101") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 101, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G3:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi101Valid") { field(INPA, "PLC:GUNB:PP02:Bi101.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:LatEqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi101 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi101Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:LatEqp") { field(DESC, "BSOIC-LAT_G3_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb101",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb101") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb101.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb101.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb101.FLNK","BSOC:GUNB:G3:LatEqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb101.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb101.VAL") #! Record("BSOC:GUNB:G3:LatEqp_calc",260,18,0,1,"BSOC:GUNB:G3:LatEqp_calc") #! Field("BSOC:GUNB:G3:LatEqp_calc.INPA",16777215,0,"BSOC:GUNB:G3:LatEqp_calc.INPA") #! Link("BSOC:GUNB:G3:LatEqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb101.VAL") #! Field("BSOC:GUNB:G3:LatEqp_calc.INPB",16777215,1,"BSOC:GUNB:G3:LatEqp_calc.INPB") #! Field("BSOC:GUNB:G3:LatEqp_calc.OUT",16777215,1,"BSOC:GUNB:G3:LatEqp_calc.OUT") #! Link("BSOC:GUNB:G3:LatEqp_calc.OUT","BSOC:GUNB:G3:LatEqp.VAL") #! Record("BSOC:GUNB:G3:LatEqp",500,20,0,0,"BSOC:GUNB:G3:LatEqp") #! Field("BSOC:GUNB:G3:LatEqp.VAL",16777215,1,"BSOC:GUNB:G3:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi100") { field(DESC, "Port GUNB_BSOIC_Rd bit 100") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 100, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G3:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi100Valid") { field(INPA, "PLC:GUNB:PP02:Bi100.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:LatRad_calc") { field(INPA, "PLC:GUNB:PP02:Bi100 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi100Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:LatRad") { field(DESC, "BSOIC-LAT_G3_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb100",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb100") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb100.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb100.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb100.FLNK","BSOC:GUNB:G3:LatRad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb100.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb100.VAL") #! Record("BSOC:GUNB:G3:LatRad_calc",260,18,0,1,"BSOC:GUNB:G3:LatRad_calc") #! Field("BSOC:GUNB:G3:LatRad_calc.INPA",16777215,0,"BSOC:GUNB:G3:LatRad_calc.INPA") #! Link("BSOC:GUNB:G3:LatRad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb100.VAL") #! Field("BSOC:GUNB:G3:LatRad_calc.INPB",16777215,1,"BSOC:GUNB:G3:LatRad_calc.INPB") #! Field("BSOC:GUNB:G3:LatRad_calc.OUT",16777215,1,"BSOC:GUNB:G3:LatRad_calc.OUT") #! Link("BSOC:GUNB:G3:LatRad_calc.OUT","BSOC:GUNB:G3:LatRad.VAL") #! Record("BSOC:GUNB:G3:LatRad",500,20,0,0,"BSOC:GUNB:G3:LatRad") #! Field("BSOC:GUNB:G3:LatRad.VAL",16777215,1,"BSOC:GUNB:G3:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi99") { field(DESC, "Port GUNB_BSOIC_Rd bit 99") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 99, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G4:LatEqp_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi99Valid") { field(INPA, "PLC:GUNB:PP02:Bi99.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:LatEqp_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:LatEqp_calc") { field(INPA, "PLC:GUNB:PP02:Bi99 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi99Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:LatEqp PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:LatEqp") { field(DESC, "BSOIC-LAT_G4_Equip_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb99",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb99") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb99.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb99.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb99.FLNK","BSOC:GUNB:G4:LatEqp_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb99.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb99.VAL") #! Record("BSOC:GUNB:G4:LatEqp_calc",260,18,0,1,"BSOC:GUNB:G4:LatEqp_calc") #! Field("BSOC:GUNB:G4:LatEqp_calc.INPA",16777215,0,"BSOC:GUNB:G4:LatEqp_calc.INPA") #! Link("BSOC:GUNB:G4:LatEqp_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb99.VAL") #! Field("BSOC:GUNB:G4:LatEqp_calc.INPB",16777215,1,"BSOC:GUNB:G4:LatEqp_calc.INPB") #! Field("BSOC:GUNB:G4:LatEqp_calc.OUT",16777215,1,"BSOC:GUNB:G4:LatEqp_calc.OUT") #! Link("BSOC:GUNB:G4:LatEqp_calc.OUT","BSOC:GUNB:G4:LatEqp.VAL") #! Record("BSOC:GUNB:G4:LatEqp",500,20,0,0,"BSOC:GUNB:G4:LatEqp") #! Field("BSOC:GUNB:G4:LatEqp.VAL",16777215,1,"BSOC:GUNB:G4:LatEqp.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi98") { field(DESC, "Port GUNB_BSOIC_Rd bit 98") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 98, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G4:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi98Valid") { field(INPA, "PLC:GUNB:PP02:Bi98.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:LatRad_calc") { field(INPA, "PLC:GUNB:PP02:Bi98 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi98Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:LatRad") { field(DESC, "BSOIC-LAT_G4_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb98",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb98") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb98.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb98.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb98.FLNK","BSOC:GUNB:G4:LatRad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb98.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb98.VAL") #! Record("BSOC:GUNB:G4:LatRad_calc",260,18,0,1,"BSOC:GUNB:G4:LatRad_calc") #! Field("BSOC:GUNB:G4:LatRad_calc.INPA",16777215,0,"BSOC:GUNB:G4:LatRad_calc.INPA") #! Link("BSOC:GUNB:G4:LatRad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb98.VAL") #! Field("BSOC:GUNB:G4:LatRad_calc.INPB",16777215,1,"BSOC:GUNB:G4:LatRad_calc.INPB") #! Field("BSOC:GUNB:G4:LatRad_calc.OUT",16777215,1,"BSOC:GUNB:G4:LatRad_calc.OUT") #! Link("BSOC:GUNB:G4:LatRad_calc.OUT","BSOC:GUNB:G4:LatRad.VAL") #! Record("BSOC:GUNB:G4:LatRad",500,20,0,0,"BSOC:GUNB:G4:LatRad") #! Field("BSOC:GUNB:G4:LatRad.VAL",16777215,1,"BSOC:GUNB:G4:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi97") { field(DESC, "Port GUNB_BSOIC_Rd bit 97") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 97, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:04N:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi97Valid") { field(INPA, "PLC:GUNB:PP02:Bi97.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:04N:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:04N:LatRad_calc") { field(INPA, "PLC:GUNB:PP02:Bi97 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi97Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:04N:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:04N:LatRad") { field(DESC, "BSOIC-LAT_N1_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb97",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb97") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb97.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb97.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb97.FLNK","BSOC:GUNB:04N:LatRad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb97.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb97.VAL") #! Record("BSOC:GUNB:04N:LatRad_calc",260,18,0,1,"BSOC:GUNB:04N:LatRad_calc") #! Field("BSOC:GUNB:04N:LatRad_calc.INPA",16777215,0,"BSOC:GUNB:04N:LatRad_calc.INPA") #! Link("BSOC:GUNB:04N:LatRad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb97.VAL") #! Field("BSOC:GUNB:04N:LatRad_calc.INPB",16777215,1,"BSOC:GUNB:04N:LatRad_calc.INPB") #! Field("BSOC:GUNB:04N:LatRad_calc.OUT",16777215,1,"BSOC:GUNB:04N:LatRad_calc.OUT") #! Link("BSOC:GUNB:04N:LatRad_calc.OUT","BSOC:GUNB:04N:LatRad.VAL") #! Record("BSOC:GUNB:04N:LatRad",500,20,0,0,"BSOC:GUNB:04N:LatRad") #! Field("BSOC:GUNB:04N:LatRad.VAL",16777215,1,"BSOC:GUNB:04N:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi96") { field(DESC, "Port GUNB_BSOIC_Rd bit 96") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 96, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:N2:LatRad_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi96Valid") { field(INPA, "PLC:GUNB:PP02:Bi96.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:N2:LatRad_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:N2:LatRad_calc") { field(INPA, "PLC:GUNB:PP02:Bi96 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi96Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:N2:LatRad PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:N2:LatRad") { field(DESC, "BSOIC-LAT_N2_RAD_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb96",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb96") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb96.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb96.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb96.FLNK","BSOC:GUNB:N2:LatRad_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb96.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb96.VAL") #! Record("BSOC:GUNB:N2:LatRad_calc",260,18,0,1,"BSOC:GUNB:N2:LatRad_calc") #! Field("BSOC:GUNB:N2:LatRad_calc.INPA",16777215,0,"BSOC:GUNB:N2:LatRad_calc.INPA") #! Link("BSOC:GUNB:N2:LatRad_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb96.VAL") #! Field("BSOC:GUNB:N2:LatRad_calc.INPB",16777215,1,"BSOC:GUNB:N2:LatRad_calc.INPB") #! Field("BSOC:GUNB:N2:LatRad_calc.OUT",16777215,1,"BSOC:GUNB:N2:LatRad_calc.OUT") #! Link("BSOC:GUNB:N2:LatRad_calc.OUT","BSOC:GUNB:N2:LatRad.VAL") #! Record("BSOC:GUNB:N2:LatRad",500,20,0,0,"BSOC:GUNB:N2:LatRad") #! Field("BSOC:GUNB:N2:LatRad.VAL",16777215,1,"BSOC:GUNB:N2:LatRad.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi111") { field(DESC, "Port GUNB_BSOIC_Rd bit 111") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 111, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi111Valid") { field(INPA, "PLC:GUNB:PP02:Bi111.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:LatCascIn_calc") { field(INPA, "PLC:GUNB:PP02:Bi111 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi111Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb111",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb111") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb111.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb111.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb111.FLNK","BSOC:GUNB:1:LatCascIn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb111.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb111.VAL") #! Record("BSOC:GUNB:1:LatCascIn_calc",260,18,0,1,"BSOC:GUNB:1:LatCascIn_calc") #! Field("BSOC:GUNB:1:LatCascIn_calc.INPA",16777215,0,"BSOC:GUNB:1:LatCascIn_calc.INPA") #! Link("BSOC:GUNB:1:LatCascIn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb111.VAL") #! Field("BSOC:GUNB:1:LatCascIn_calc.INPB",16777215,1,"BSOC:GUNB:1:LatCascIn_calc.INPB") #! Field("BSOC:GUNB:1:LatCascIn_calc.OUT",16777215,1,"BSOC:GUNB:1:LatCascIn_calc.OUT") #! Link("BSOC:GUNB:1:LatCascIn_calc.OUT","BSOC:GUNB:1:LatCascIn.VAL") #! Record("BSOC:GUNB:1:LatCascIn",500,20,0,0,"BSOC:GUNB:1:LatCascIn") #! Field("BSOC:GUNB:1:LatCascIn.VAL",16777215,1,"BSOC:GUNB:1:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi110") { field(DESC, "Port GUNB_BSOIC_Rd bit 110") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 110, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:2:LatCascIn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi110Valid") { field(INPA, "PLC:GUNB:PP02:Bi110.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:2:LatCascIn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:2:LatCascIn_calc") { field(INPA, "PLC:GUNB:PP02:Bi110 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi110Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:2:LatCascIn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:2:LatCascIn") { field(DESC, "BSOIC-LAT_CASCADE_Inp2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb110",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb110") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb110.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb110.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb110.FLNK","BSOC:GUNB:2:LatCascIn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb110.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb110.VAL") #! Record("BSOC:GUNB:2:LatCascIn_calc",260,18,0,1,"BSOC:GUNB:2:LatCascIn_calc") #! Field("BSOC:GUNB:2:LatCascIn_calc.INPA",16777215,0,"BSOC:GUNB:2:LatCascIn_calc.INPA") #! Link("BSOC:GUNB:2:LatCascIn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb110.VAL") #! Field("BSOC:GUNB:2:LatCascIn_calc.INPB",16777215,1,"BSOC:GUNB:2:LatCascIn_calc.INPB") #! Field("BSOC:GUNB:2:LatCascIn_calc.OUT",16777215,1,"BSOC:GUNB:2:LatCascIn_calc.OUT") #! Link("BSOC:GUNB:2:LatCascIn_calc.OUT","BSOC:GUNB:2:LatCascIn.VAL") #! Record("BSOC:GUNB:2:LatCascIn",500,20,0,0,"BSOC:GUNB:2:LatCascIn") #! Field("BSOC:GUNB:2:LatCascIn.VAL",16777215,1,"BSOC:GUNB:2:LatCascIn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi109") { field(DESC, "Port GUNB_BSOIC_Rd bit 109") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 109, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:AllGOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi109Valid") { field(INPA, "PLC:GUNB:PP02:Bi109.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:AllGOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:AllGOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi109 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi109Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:AllGOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:AllGOk") { field(DESC, "BSOIC-All_Gamma_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb109",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb109") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb109.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb109.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb109.FLNK","BSOC:GUNB:1:AllGOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb109.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb109.VAL") #! Record("BSOC:GUNB:1:AllGOk_calc",260,18,0,1,"BSOC:GUNB:1:AllGOk_calc") #! Field("BSOC:GUNB:1:AllGOk_calc.INPA",16777215,0,"BSOC:GUNB:1:AllGOk_calc.INPA") #! Link("BSOC:GUNB:1:AllGOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb109.VAL") #! Field("BSOC:GUNB:1:AllGOk_calc.INPB",16777215,1,"BSOC:GUNB:1:AllGOk_calc.INPB") #! Field("BSOC:GUNB:1:AllGOk_calc.OUT",16777215,1,"BSOC:GUNB:1:AllGOk_calc.OUT") #! Link("BSOC:GUNB:1:AllGOk_calc.OUT","BSOC:GUNB:1:AllGOk.VAL") #! Record("BSOC:GUNB:1:AllGOk",500,20,0,0,"BSOC:GUNB:1:AllGOk") #! Field("BSOC:GUNB:1:AllGOk.VAL",16777215,1,"BSOC:GUNB:1:AllGOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi108") { field(DESC, "Port GUNB_BSOIC_Rd bit 108") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 108, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:AllNOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi108Valid") { field(INPA, "PLC:GUNB:PP02:Bi108.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:AllNOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:AllNOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi108 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi108Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:AllNOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:AllNOk") { field(DESC, "BSOIC-All_Neutron_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb108",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb108") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb108.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb108.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb108.FLNK","BSOC:GUNB:1:AllNOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb108.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb108.VAL") #! Record("BSOC:GUNB:1:AllNOk_calc",260,18,0,1,"BSOC:GUNB:1:AllNOk_calc") #! Field("BSOC:GUNB:1:AllNOk_calc.INPA",16777215,0,"BSOC:GUNB:1:AllNOk_calc.INPA") #! Link("BSOC:GUNB:1:AllNOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb108.VAL") #! Field("BSOC:GUNB:1:AllNOk_calc.INPB",16777215,1,"BSOC:GUNB:1:AllNOk_calc.INPB") #! Field("BSOC:GUNB:1:AllNOk_calc.OUT",16777215,1,"BSOC:GUNB:1:AllNOk_calc.OUT") #! Link("BSOC:GUNB:1:AllNOk_calc.OUT","BSOC:GUNB:1:AllNOk.VAL") #! Record("BSOC:GUNB:1:AllNOk",500,20,0,0,"BSOC:GUNB:1:AllNOk") #! Field("BSOC:GUNB:1:AllNOk.VAL",16777215,1,"BSOC:GUNB:1:AllNOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi107") { field(DESC, "Port GUNB_BSOIC_Rd bit 107") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 107, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:1:AllOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi107Valid") { field(INPA, "PLC:GUNB:PP02:Bi107.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:AllOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:AllOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi107 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi107Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:AllOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:AllOk") { field(DESC, "BSOIC-All_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb107",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb107") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb107.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb107.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb107.FLNK","BSOC:GUNB:1:AllOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb107.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb107.VAL") #! Record("BSOC:GUNB:1:AllOk_calc",260,18,0,1,"BSOC:GUNB:1:AllOk_calc") #! Field("BSOC:GUNB:1:AllOk_calc.INPA",16777215,0,"BSOC:GUNB:1:AllOk_calc.INPA") #! Link("BSOC:GUNB:1:AllOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb107.VAL") #! Field("BSOC:GUNB:1:AllOk_calc.INPB",16777215,1,"BSOC:GUNB:1:AllOk_calc.INPB") #! Field("BSOC:GUNB:1:AllOk_calc.OUT",16777215,1,"BSOC:GUNB:1:AllOk_calc.OUT") #! Link("BSOC:GUNB:1:AllOk_calc.OUT","BSOC:GUNB:1:AllOk.VAL") #! Record("BSOC:GUNB:1:AllOk",500,20,0,0,"BSOC:GUNB:1:AllOk") #! Field("BSOC:GUNB:1:AllOk.VAL",16777215,1,"BSOC:GUNB:1:AllOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi106") { field(DESC, "Port GUNB_BSOIC_Rd bit 106") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 106, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:GUNB:03:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi106Valid") { field(INPA, "PLC:GUNB:PP02:Bi106.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:EqpWarn_calc") { field(INPA, "PLC:GUNB:PP02:Bi106 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi106Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb106",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb106") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb106.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb106.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb106.FLNK","BSOC:GUNB:03:EqpWarn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb106.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb106.VAL") #! Record("BSOC:GUNB:03:EqpWarn_calc",260,18,0,1,"BSOC:GUNB:03:EqpWarn_calc") #! Field("BSOC:GUNB:03:EqpWarn_calc.INPA",16777215,0,"BSOC:GUNB:03:EqpWarn_calc.INPA") #! Link("BSOC:GUNB:03:EqpWarn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb106.VAL") #! Field("BSOC:GUNB:03:EqpWarn_calc.INPB",16777215,1,"BSOC:GUNB:03:EqpWarn_calc.INPB") #! Field("BSOC:GUNB:03:EqpWarn_calc.OUT",16777215,1,"BSOC:GUNB:03:EqpWarn_calc.OUT") #! Link("BSOC:GUNB:03:EqpWarn_calc.OUT","BSOC:GUNB:03:EqpWarn.VAL") #! Record("BSOC:GUNB:03:EqpWarn",500,20,0,0,"BSOC:GUNB:03:EqpWarn") #! Field("BSOC:GUNB:03:EqpWarn.VAL",16777215,1,"BSOC:GUNB:03:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi105") { field(DESC, "Port GUNB_BSOIC_Rd bit 105") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 105, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:GUNB:G2:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi105Valid") { field(INPA, "PLC:GUNB:PP02:Bi105.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:EqpWarn_calc") { field(INPA, "PLC:GUNB:PP02:Bi105 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi105Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb105",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb105") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb105.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb105.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb105.FLNK","BSOC:GUNB:G2:EqpWarn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb105.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb105.VAL") #! Record("BSOC:GUNB:G2:EqpWarn_calc",260,18,0,1,"BSOC:GUNB:G2:EqpWarn_calc") #! Field("BSOC:GUNB:G2:EqpWarn_calc.INPA",16777215,0,"BSOC:GUNB:G2:EqpWarn_calc.INPA") #! Link("BSOC:GUNB:G2:EqpWarn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb105.VAL") #! Field("BSOC:GUNB:G2:EqpWarn_calc.INPB",16777215,1,"BSOC:GUNB:G2:EqpWarn_calc.INPB") #! Field("BSOC:GUNB:G2:EqpWarn_calc.OUT",16777215,1,"BSOC:GUNB:G2:EqpWarn_calc.OUT") #! Link("BSOC:GUNB:G2:EqpWarn_calc.OUT","BSOC:GUNB:G2:EqpWarn.VAL") #! Record("BSOC:GUNB:G2:EqpWarn",500,20,0,0,"BSOC:GUNB:G2:EqpWarn") #! Field("BSOC:GUNB:G2:EqpWarn.VAL",16777215,1,"BSOC:GUNB:G2:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi104") { field(DESC, "Port GUNB_BSOIC_Rd bit 104") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 104, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:GUNB:G3:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi104Valid") { field(INPA, "PLC:GUNB:PP02:Bi104.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:EqpWarn_calc") { field(INPA, "PLC:GUNB:PP02:Bi104 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi104Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb104",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb104") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb104.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb104.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb104.FLNK","BSOC:GUNB:G3:EqpWarn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb104.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb104.VAL") #! Record("BSOC:GUNB:G3:EqpWarn_calc",260,18,0,1,"BSOC:GUNB:G3:EqpWarn_calc") #! Field("BSOC:GUNB:G3:EqpWarn_calc.INPA",16777215,0,"BSOC:GUNB:G3:EqpWarn_calc.INPA") #! Link("BSOC:GUNB:G3:EqpWarn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb104.VAL") #! Field("BSOC:GUNB:G3:EqpWarn_calc.INPB",16777215,1,"BSOC:GUNB:G3:EqpWarn_calc.INPB") #! Field("BSOC:GUNB:G3:EqpWarn_calc.OUT",16777215,1,"BSOC:GUNB:G3:EqpWarn_calc.OUT") #! Link("BSOC:GUNB:G3:EqpWarn_calc.OUT","BSOC:GUNB:G3:EqpWarn.VAL") #! Record("BSOC:GUNB:G3:EqpWarn",500,20,0,0,"BSOC:GUNB:G3:EqpWarn") #! Field("BSOC:GUNB:G3:EqpWarn.VAL",16777215,1,"BSOC:GUNB:G3:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi119") { field(DESC, "Port GUNB_BSOIC_Rd bit 119") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 119, 1, 1)") field(ZNAM, "Ok") field(ONAM, "Fault") field(FLNK, "BSOC:GUNB:G4:EqpWarn_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi119Valid") { field(INPA, "PLC:GUNB:PP02:Bi119.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:EqpWarn_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:EqpWarn_calc") { field(INPA, "PLC:GUNB:PP02:Bi119 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi119Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:EqpWarn PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:EqpWarn") { field(DESC, "BSOIC-Equip_Warn_G4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb119",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb119") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb119.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb119.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb119.FLNK","BSOC:GUNB:G4:EqpWarn_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb119.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb119.VAL") #! Record("BSOC:GUNB:G4:EqpWarn_calc",260,18,0,1,"BSOC:GUNB:G4:EqpWarn_calc") #! Field("BSOC:GUNB:G4:EqpWarn_calc.INPA",16777215,0,"BSOC:GUNB:G4:EqpWarn_calc.INPA") #! Link("BSOC:GUNB:G4:EqpWarn_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb119.VAL") #! Field("BSOC:GUNB:G4:EqpWarn_calc.INPB",16777215,1,"BSOC:GUNB:G4:EqpWarn_calc.INPB") #! Field("BSOC:GUNB:G4:EqpWarn_calc.OUT",16777215,1,"BSOC:GUNB:G4:EqpWarn_calc.OUT") #! Link("BSOC:GUNB:G4:EqpWarn_calc.OUT","BSOC:GUNB:G4:EqpWarn.VAL") #! Record("BSOC:GUNB:G4:EqpWarn",500,20,0,0,"BSOC:GUNB:G4:EqpWarn") #! Field("BSOC:GUNB:G4:EqpWarn.VAL",16777215,1,"BSOC:GUNB:G4:EqpWarn.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi117") { field(DESC, "Port GUNB_BSOIC_Rd bit 117") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 117, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(FLNK, "BSOC:GUNB:1:PLCHB_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi117Valid") { field(INPA, "PLC:GUNB:PP02:Bi117.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:1:PLCHB_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:1:PLCHB_calc") { field(INPA, "PLC:GUNB:PP02:Bi117 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi117Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:1:PLCHB PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:1:PLCHB") { field(DESC, "BSOIC-PLC_Heartbeat") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb117",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb117") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb117.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb117.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb117.FLNK","BSOC:GUNB:1:PLCHB_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb117.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb117.VAL") #! Record("BSOC:GUNB:1:PLCHB_calc",260,18,0,1,"BSOC:GUNB:1:PLCHB_calc") #! Field("BSOC:GUNB:1:PLCHB_calc.INPA",16777215,0,"BSOC:GUNB:1:PLCHB_calc.INPA") #! Link("BSOC:GUNB:1:PLCHB_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb117.VAL") #! Field("BSOC:GUNB:1:PLCHB_calc.INPB",16777215,1,"BSOC:GUNB:1:PLCHB_calc.INPB") #! Field("BSOC:GUNB:1:PLCHB_calc.OUT",16777215,1,"BSOC:GUNB:1:PLCHB_calc.OUT") #! Link("BSOC:GUNB:1:PLCHB_calc.OUT","BSOC:GUNB:1:PLCHB.VAL") #! Record("BSOC:GUNB:1:PLCHB",500,20,0,0,"BSOC:GUNB:1:PLCHB") #! Field("BSOC:GUNB:1:PLCHB.VAL",16777215,1,"BSOC:GUNB:1:PLCHB.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi116") { field(DESC, "Port GUNB_BSOIC_Rd bit 116") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 116, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:03:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi116Valid") { field(INPA, "PLC:GUNB:PP02:Bi116.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:03:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:03:ChOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi116 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi116Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:03:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:03:ChOk") { field(DESC, "BSOIC-CH1_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb116",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb116") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb116.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb116.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb116.FLNK","BSOC:GUNB:03:ChOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb116.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb116.VAL") #! Record("BSOC:GUNB:03:ChOk_calc",260,18,0,1,"BSOC:GUNB:03:ChOk_calc") #! Field("BSOC:GUNB:03:ChOk_calc.INPA",16777215,0,"BSOC:GUNB:03:ChOk_calc.INPA") #! Link("BSOC:GUNB:03:ChOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb116.VAL") #! Field("BSOC:GUNB:03:ChOk_calc.INPB",16777215,1,"BSOC:GUNB:03:ChOk_calc.INPB") #! Field("BSOC:GUNB:03:ChOk_calc.OUT",16777215,1,"BSOC:GUNB:03:ChOk_calc.OUT") #! Link("BSOC:GUNB:03:ChOk_calc.OUT","BSOC:GUNB:03:ChOk.VAL") #! Record("BSOC:GUNB:03:ChOk",500,20,0,0,"BSOC:GUNB:03:ChOk") #! Field("BSOC:GUNB:03:ChOk.VAL",16777215,1,"BSOC:GUNB:03:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi115") { field(DESC, "Port GUNB_BSOIC_Rd bit 115") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 115, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G2:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi115Valid") { field(INPA, "PLC:GUNB:PP02:Bi115.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G2:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G2:ChOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi115 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi115Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G2:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G2:ChOk") { field(DESC, "BSOIC-CH2_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb115",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb115") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb115.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb115.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb115.FLNK","BSOC:GUNB:G2:ChOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb115.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb115.VAL") #! Record("BSOC:GUNB:G2:ChOk_calc",260,18,0,1,"BSOC:GUNB:G2:ChOk_calc") #! Field("BSOC:GUNB:G2:ChOk_calc.INPA",16777215,0,"BSOC:GUNB:G2:ChOk_calc.INPA") #! Link("BSOC:GUNB:G2:ChOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb115.VAL") #! Field("BSOC:GUNB:G2:ChOk_calc.INPB",16777215,1,"BSOC:GUNB:G2:ChOk_calc.INPB") #! Field("BSOC:GUNB:G2:ChOk_calc.OUT",16777215,1,"BSOC:GUNB:G2:ChOk_calc.OUT") #! Link("BSOC:GUNB:G2:ChOk_calc.OUT","BSOC:GUNB:G2:ChOk.VAL") #! Record("BSOC:GUNB:G2:ChOk",500,20,0,0,"BSOC:GUNB:G2:ChOk") #! Field("BSOC:GUNB:G2:ChOk.VAL",16777215,1,"BSOC:GUNB:G2:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi114") { field(DESC, "Port GUNB_BSOIC_Rd bit 114") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 114, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G3:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi114Valid") { field(INPA, "PLC:GUNB:PP02:Bi114.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G3:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G3:ChOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi114 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi114Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G3:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G3:ChOk") { field(DESC, "BSOIC-CH3_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb114",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb114") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb114.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb114.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb114.FLNK","BSOC:GUNB:G3:ChOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb114.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb114.VAL") #! Record("BSOC:GUNB:G3:ChOk_calc",260,18,0,1,"BSOC:GUNB:G3:ChOk_calc") #! Field("BSOC:GUNB:G3:ChOk_calc.INPA",16777215,0,"BSOC:GUNB:G3:ChOk_calc.INPA") #! Link("BSOC:GUNB:G3:ChOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb114.VAL") #! Field("BSOC:GUNB:G3:ChOk_calc.INPB",16777215,1,"BSOC:GUNB:G3:ChOk_calc.INPB") #! Field("BSOC:GUNB:G3:ChOk_calc.OUT",16777215,1,"BSOC:GUNB:G3:ChOk_calc.OUT") #! Link("BSOC:GUNB:G3:ChOk_calc.OUT","BSOC:GUNB:G3:ChOk.VAL") #! Record("BSOC:GUNB:G3:ChOk",500,20,0,0,"BSOC:GUNB:G3:ChOk") #! Field("BSOC:GUNB:G3:ChOk.VAL",16777215,1,"BSOC:GUNB:G3:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi113") { field(DESC, "Port GUNB_BSOIC_Rd bit 113") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 113, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:G4:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi113Valid") { field(INPA, "PLC:GUNB:PP02:Bi113.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:G4:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:G4:ChOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi113 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi113Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:G4:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:G4:ChOk") { field(DESC, "BSOIC-CH4_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb113",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb113") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb113.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb113.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb113.FLNK","BSOC:GUNB:G4:ChOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb113.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb113.VAL") #! Record("BSOC:GUNB:G4:ChOk_calc",260,18,0,1,"BSOC:GUNB:G4:ChOk_calc") #! Field("BSOC:GUNB:G4:ChOk_calc.INPA",16777215,0,"BSOC:GUNB:G4:ChOk_calc.INPA") #! Link("BSOC:GUNB:G4:ChOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb113.VAL") #! Field("BSOC:GUNB:G4:ChOk_calc.INPB",16777215,1,"BSOC:GUNB:G4:ChOk_calc.INPB") #! Field("BSOC:GUNB:G4:ChOk_calc.OUT",16777215,1,"BSOC:GUNB:G4:ChOk_calc.OUT") #! Link("BSOC:GUNB:G4:ChOk_calc.OUT","BSOC:GUNB:G4:ChOk.VAL") #! Record("BSOC:GUNB:G4:ChOk",500,20,0,0,"BSOC:GUNB:G4:ChOk") #! Field("BSOC:GUNB:G4:ChOk.VAL",16777215,1,"BSOC:GUNB:G4:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi112") { field(DESC, "Port GUNB_BSOIC_Rd bit 112") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 112, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:04N:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi112Valid") { field(INPA, "PLC:GUNB:PP02:Bi112.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:04N:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:04N:ChOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi112 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi112Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:04N:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:04N:ChOk") { field(DESC, "BSOIC-CH5_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb112",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb112") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb112.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb112.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb112.FLNK","BSOC:GUNB:04N:ChOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb112.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb112.VAL") #! Record("BSOC:GUNB:04N:ChOk_calc",260,18,0,1,"BSOC:GUNB:04N:ChOk_calc") #! Field("BSOC:GUNB:04N:ChOk_calc.INPA",16777215,0,"BSOC:GUNB:04N:ChOk_calc.INPA") #! Link("BSOC:GUNB:04N:ChOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb112.VAL") #! Field("BSOC:GUNB:04N:ChOk_calc.INPB",16777215,1,"BSOC:GUNB:04N:ChOk_calc.INPB") #! Field("BSOC:GUNB:04N:ChOk_calc.OUT",16777215,1,"BSOC:GUNB:04N:ChOk_calc.OUT") #! Link("BSOC:GUNB:04N:ChOk_calc.OUT","BSOC:GUNB:04N:ChOk.VAL") #! Record("BSOC:GUNB:04N:ChOk",500,20,0,0,"BSOC:GUNB:04N:ChOk") #! Field("BSOC:GUNB:04N:ChOk.VAL",16777215,1,"BSOC:GUNB:04N:ChOk.VAL") #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(bi, "PLC:GUNB:PP02:Bi127") { field(DESC, "Port GUNB_BSOIC_Rd bit 127") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 127, 1, 1)") field(ZNAM, "Fault") field(ONAM, "Ok") field(FLNK, "BSOC:GUNB:N2:ChOk_calc PP NMS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:Bi127Valid") { field(INPA, "PLC:GUNB:PP02:Bi127.SEVR NPP NMS") field(CALC, "A=3?VAL+1:0") #Go invalid if input is invalid for 3 seconds field(HIHI, 9) field(HHSV, "INVALID") field(OUT, "BSOC:GUNB:N2:ChOk_calc.C PP MSI") field(SCAN, "1 second") field(ASG, "Internal") field(OOPT, "On Change") } record(calcout, "BSOC:GUNB:N2:ChOk_calc") { field(INPA, "PLC:GUNB:PP02:Bi127 NPP NMS") field(INPB, "PLC:GUNB:PP02:TABLE_9_SEG_1 CP NMS") # Input C is for setting invalid severity, not used otherwise field(INPC, "PLC:GUNB:PP02:Bi127Valid NPP MSI") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "BSOC:GUNB:N2:ChOk PP MS") field(ASG, "Internal") } record(bi, "BSOC:GUNB:N2:ChOk") { field(DESC, "BSOIC-CH6_OK") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("PLC:GUNB:PP02:GUNB_BSOIC_Rdb127",20,19,0,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb127") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb127.FLNK",16777215,1,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb127.FLNK") #! Link("PLC:GUNB:PP02:GUNB_BSOIC_Rdb127.FLNK","BSOC:GUNB:N2:ChOk_calc") #! Field("PLC:GUNB:PP02:GUNB_BSOIC_Rdb127.VAL",16777215,0,"PLC:GUNB:PP02:GUNB_BSOIC_Rdb127.VAL") #! Record("BSOC:GUNB:N2:ChOk_calc",260,18,0,1,"BSOC:GUNB:N2:ChOk_calc") #! Field("BSOC:GUNB:N2:ChOk_calc.INPA",16777215,0,"BSOC:GUNB:N2:ChOk_calc.INPA") #! Link("BSOC:GUNB:N2:ChOk_calc.INPA","PLC:GUNB:PP02:GUNB_BSOIC_Rdb127.VAL") #! Field("BSOC:GUNB:N2:ChOk_calc.INPB",16777215,1,"BSOC:GUNB:N2:ChOk_calc.INPB") #! Field("BSOC:GUNB:N2:ChOk_calc.OUT",16777215,1,"BSOC:GUNB:N2:ChOk_calc.OUT") #! Link("BSOC:GUNB:N2:ChOk_calc.OUT","BSOC:GUNB:N2:ChOk.VAL") #! Record("BSOC:GUNB:N2:ChOk",500,20,0,0,"BSOC:GUNB:N2:ChOk") #! Field("BSOC:GUNB:N2:ChOk.VAL",16777215,1,"BSOC:GUNB:N2:ChOk.VAL") record(bo, "BSOC:GUNB:03:SReset") { field(DESC, "BSOIC-Soft_Reset_G1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 7, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:G2:SReset") { field(DESC, "BSOIC-Soft_Reset_G2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 6, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:G3:SReset") { field(DESC, "BSOIC-Soft_Reset_G3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 5, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:G4:SReset") { field(DESC, "BSOIC-Soft_Reset_G4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 4, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:04N:SReset") { field(DESC, "BSOIC-Soft_Reset_N1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 3, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:N2:SReset") { field(DESC, "BSOIC-Soft_Reset_N2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 2, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:1:SResetAll") { field(DESC, "BSOIC-Soft_Reset_All") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 1, 1, 1)") field(ZNAM, "Off") field(ONAM, "Reset") field(ASG, "") } record(bo, "BSOC:GUNB:1:SPauseHB") { field(DESC, "BSOIC-Soft_Pause_Hb") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 0, 1, 1)") field(ZNAM, "Off") field(ONAM, "Pause") field(ASG, "MCC") } #============================================================================== # # Abs: PILZ PNOZ PLC interface for accessing the right table/segment # # Name: pilz-plc-request.template # # Facility: LCLS Personnel Protection Controls # # Auth: 11-Dec-2018, Garth Brown (GWBROWN) # Rev : dd-mmm-yyyy, Reviewer's Name (USERNAME) # # To specify which registers to read/write, you need to set the table and # segment (see PNOZ docs). This set of PVs keeps them set to the correct values # for reading either virtual I/O points or program stats such as project checksum. # The PNOZ PLC also has occasional communications dropouts, where the PLC stops # responding and the TCP connection must be reset. This happens more frequently # the more communication there is with the PLC. # While the vendor offers a PNOZ model with integrated Ethernet port which # allows readback at different modbus addresses instead of needing to set # table/segment, that interface also allows remote access to secure registers # and PLC programming. For safety, that type of remote access is not allowed in # our system. All of their products that don't allow remote access beyond our # safety specs also require table/segment setting to choose which registers to # read/write. # #----------------------------------------------------------------------------- # Mod: # #============================================================================== # record(longout, "PLC:GUNB:PP02:REQ_TABLE") { field(DESC, "Table to read/write") field(VAL, "9") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # All the data we're interested in is: Tables 1 and 9, segment 1 # We only need table 1 once for check sums that don't change, so # read it for a short time during startup, then switch to table 9. record(calcout, "PLC:GUNB:PP02:TABLE_CYCLER") { field( OUT, "PLC:GUNB:PP02:REQ_TABLE PP") field( CALC, "A:=(A+1)%3600;A=20?1:9") field( INPA, "0") field( SCAN, ".5 second") } record(calcout, "PLC:GUNB:PP02:SEG_CYCLER") { field( OUT, "PLC:GUNB:PP02:REQ_SEG PP") field( CALC, "1") field( INPA, "0") field( SCAN, ".5 second") } # Records for disabling PVs when their reqest table isn't active record(calc, "PLC:GUNB:PP02:TABLE_9_SEG_1") { field( INPA, "PLC:GUNB:PP02:REQ_TABLE CP") field( INPB, "PLC:GUNB:PP02:REQ_SEG CP") field( INPC, "PLC:GUNB:PP02:REQ_TABLE_IN CP") field( INPD, "PLC:GUNB:PP02:REQ_SEG_IN CP") field(CALC, "A=9 & B=1 & C=9 & D=1") } record(calc, "PLC:GUNB:PP02:TABLE_1_SEG_1") { field( INPA, "PLC:GUNB:PP02:REQ_TABLE CP") field( INPB, "PLC:GUNB:PP02:REQ_SEG CP") field( INPC, "PLC:GUNB:PP02:REQ_TABLE_IN CP") field( INPD, "PLC:GUNB:PP02:REQ_SEG_IN CP") field(CALC, "A=1 & B=1 & C=1 & D=1") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:GUNB:PP02:REQ_TABLE_OUT") { field(OUTA, "PLC:GUNB:PP02:REQ_TABLE_BIT0_CALC.A PP") field(OUTB, "PLC:GUNB:PP02:REQ_TABLE_BIT1_CALC.A PP") field(OUTC, "PLC:GUNB:PP02:REQ_TABLE_BIT2_CALC.A PP") field(OUTD, "PLC:GUNB:PP02:REQ_TABLE_BIT3_CALC.A PP") field(OUTE, "PLC:GUNB:PP02:REQ_TABLE_BIT4_CALC.A PP") field(OUTF, "PLC:GUNB:PP02:REQ_TABLE_BIT5_CALC.A PP") field(OUTG, "PLC:GUNB:PP02:REQ_TABLE_BIT6_CALC.A PP") field(OUTH, "PLC:GUNB:PP02:REQ_TABLE_BIT7_CALC.A PP") field(SDIS, "PLC:GUNB:PP02:REQ_TABLE_IN.PACT") } # The simpler approach of writing to the table/segment every few seconds caused # TCP dropouts to happen several times an hour, compared to every day or two # when we only ever read/wrote table 9 segment 1. These calcout records reduce # the dropouts to around 5 a day by only writing the bits that need to change. record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT0_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT0 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT0 MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT0 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT1_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT1 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT1 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT2_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT2 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT2 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT3_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT3 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT3 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT4_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT4 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT4 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT5_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT5 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT5 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT6_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT6 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT6 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_BIT7_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_TABLE_OUT") field(INPB, "PLC:GUNB:PP02:TABLE_BIT7 MS") field(INPC, "PLC:GUNB:PP02:REQ_TABLE_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:GUNB:PP02:REQ_TABLE_BIT7 PP") } record(calcout, "PLC:GUNB:PP02:REQ_TABLE_IN") { field(DESC, "Table readback") field(INPA, "PLC:GUNB:PP02:TABLE_BIT0 CP MS") field(INPB, "PLC:GUNB:PP02:TABLE_BIT1 CP MS") field(INPC, "PLC:GUNB:PP02:TABLE_BIT2 CP MS") field(INPD, "PLC:GUNB:PP02:TABLE_BIT3 CP MS") field(INPE, "PLC:GUNB:PP02:TABLE_BIT4 CP MS") field(INPF, "PLC:GUNB:PP02:TABLE_BIT5 CP MS") field(INPG, "PLC:GUNB:PP02:TABLE_BIT6 CP MS") field(INPH, "PLC:GUNB:PP02:TABLE_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:GUNB:PP02:REQ_TABLE PP MS") #field(SDIS, "PLC:GUNB:PP02:REQ_TABLE_OUT.PACT") } record(longout, "PLC:GUNB:PP02:REQ_SEG") { field(DESC, "Segment to read/write") field(VAL, "1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_OUT PP") field(HOPR, "128") field(LOPR, "0") field(PINI, "YES") info(autosaveFields, "VAL") } # The target PVs don't use the data, but this has 8 forward links, # the number we need, while the fanout record only has 6. record(dfanout, "PLC:GUNB:PP02:REQ_SEG_OUT") { field(OUTA, "PLC:GUNB:PP02:REQ_SEG_BIT0_CALC.A PP") field(OUTB, "PLC:GUNB:PP02:REQ_SEG_BIT1_CALC.A PP") field(OUTC, "PLC:GUNB:PP02:REQ_SEG_BIT2_CALC.A PP") field(OUTD, "PLC:GUNB:PP02:REQ_SEG_BIT3_CALC.A PP") field(OUTE, "PLC:GUNB:PP02:REQ_SEG_BIT4_CALC.A PP") field(OUTF, "PLC:GUNB:PP02:REQ_SEG_BIT5_CALC.A PP") field(OUTG, "PLC:GUNB:PP02:REQ_SEG_BIT6_CALC.A PP") field(OUTH, "PLC:GUNB:PP02:REQ_SEG_BIT7_CALC.A PP") field(SDIS, "PLC:GUNB:PP02:REQ_SEG_IN.PACT") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT0_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT0 CP MS") field(CALC, "(B#C)||(B#(A&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "A&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT0 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT1_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT1 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT1 MS") field(CALC, "(B#C)||(B#((A>>1)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>1)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT1 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT2_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT2 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT2 MS") field(CALC, "(B#C)||(B#((A>>2)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>2)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT2 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT3_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT3 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT3 MS") field(CALC, "(B#C)||(B#((A>>3)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>3)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT3 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT4_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT4 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT4 MS") field(CALC, "(B#C)||(B#((A>>4)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>4)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT4 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT5_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT5 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT5 MS") field(CALC, "(B#C)||(B#((A>>5)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>5)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT5 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT6_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT6 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT6 MS") field(CALC, "(B#C)||(B#((A>>6)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>6)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT6 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_BIT7_CALC") { field(INPA, "PLC:GUNB:PP02:REQ_SEG_OUT") field(INPB, "PLC:GUNB:PP02:SEG_BIT7 MS") field(INPC, "PLC:GUNB:PP02:REQ_SEG_BIT7 MS") field(CALC, "(B#C)||(B#((A>>7)&1))") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OCAL, "(A>>7)&1") field(OUT, "PLC:GUNB:PP02:REQ_SEG_BIT7 PP") } record(calcout, "PLC:GUNB:PP02:REQ_SEG_IN") { field(DESC, "Segment readback") field(INPA, "PLC:GUNB:PP02:SEG_BIT0 CP MS") field(INPB, "PLC:GUNB:PP02:SEG_BIT1 CP MS") field(INPC, "PLC:GUNB:PP02:SEG_BIT2 CP MS") field(INPD, "PLC:GUNB:PP02:SEG_BIT3 CP MS") field(INPE, "PLC:GUNB:PP02:SEG_BIT4 CP MS") field(INPF, "PLC:GUNB:PP02:SEG_BIT5 CP MS") field(INPG, "PLC:GUNB:PP02:SEG_BIT6 CP MS") field(INPH, "PLC:GUNB:PP02:SEG_BIT7 CP MS") field(CALC, "A+B*2+C*4+D*8+E*16+F*32+G*64+H*128") field(OUT, "PLC:GUNB:PP02:REQ_SEG PP MS") field(SDIS, "PLC:GUNB:PP02:REQ_SEG_OUT.PACT") } record(bi, "PLC:GUNB:PP02:LED_X1") { field(DESC, "PPS-X1_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 24, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:LED_X2") { field(DESC, "PPS-X2_LED") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 25, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:PWLED") { field(DESC, "PLC-Power_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 26, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:RUNLED") { field(DESC, "PLC-Run_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 27, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:DIAGLED") { field(DESC, "PLC-Diag_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 28, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:FAULTLED") { field(DESC, "PLC-Fault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 29, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:IFAULTLED") { field(DESC, "PLC-IFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 30, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:OFAULTLED") { field(DESC, "PLC-OFault_LED_A") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 31, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT7") { field(DESC, "Table Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT6") { field(DESC, "Table Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT5") { field(DESC, "Table Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT4") { field(DESC, "Table Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT3") { field(DESC, "Table Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT2") { field(DESC, "Table Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT1") { field(DESC, "Table Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:TABLE_BIT0") { field(DESC, "Table Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT7") { field(DESC, "Segment Read bit 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT6") { field(DESC, "Segment Read bit 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT5") { field(DESC, "Segment Read bit 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT4") { field(DESC, "Segment Read bit 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT3") { field(DESC, "Segment Read bit 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT2") { field(DESC, "Segment Read bit 2") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT1") { field(DESC, "Segment Read bit 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bi, "PLC:GUNB:PP02:SEG_BIT0") { field(DESC, "Segment Read bit 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Rd, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") info(autosaveFields_pass0, "SEVR") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT7") { field(DESC, "Table Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 32, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT6") { field(DESC, "Table Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 33, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT5") { field(DESC, "Table Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 34, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT4") { field(DESC, "Table Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 35, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT3") { field(DESC, "Table Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 36, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT2") { field(DESC, "Table Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 37, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT1") { field(DESC, "Table Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 38, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_TABLE_BIT0") { field(DESC, "Table Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 39, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT7") { field(DESC, "Segment Request bit 7") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 40, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT6") { field(DESC, "Segment Request bit 6") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 41, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT5") { field(DESC, "Segment Request bit 5") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 42, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT4") { field(DESC, "Segment Request bit 4") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 43, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT3") { field(DESC, "Segment Request bit 3") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 44, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT2") { field(DESC, "Segment Request bit 2") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 45, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT1") { field(DESC, "Segment Request bit 1") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 46, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PLC:GUNB:PP02:REQ_SEG_BIT0") { field(DESC, "Segment Request bit 0") field(DTYP, "asynUInt32Digital") field(OUT, "@asynMask(GUNB_BSOIC_Wrt, 47, 1, 1)") field(ZNAM, "Off") field(ONAM, "On") } #! Generated by VisualDCT v2.7.0 #! DBDSTART #! DBDEND record(longin, "PLC:GUNB:PP02:w0") { field(DESC, "Checksum word 0") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 0, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:w1") { field(DESC, "Checksum word 1") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 1, 0xFFFF, 1)") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:w2") { field(DESC, "Active Table and Segment") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 2, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:CHECKSUM_SDIS PP MS") field(ASG, "Internal") } record(calc, "PLC:GUNB:PP02:CHECKSUM_SDIS") { field(INPA, "PLC:GUNB:PP02:w2 NPP MS") field(CALC, "A = 0X0101") } record(longin, "PLC:GUNB:PP02:w3") { field(DESC, "Checksum word 3") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 3, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:CHECKSUM_SAFE_calc") { field(INPA, "PLC:GUNB:PP02:w3 PP MS") field(INPB, "PLC:GUNB:PP02:CHECKSUM_SDIS PP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:GUNB:PP02:CHECKSUM_SAFE PP MS") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:CHECKSUM_SAFE") { field(DESC, "Check Sum Safe") field(FLNK, "PLC:GUNB:PP02:CHECKSUM_SAFE_calc PP MS") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:GUNB:PP02:w4") { field(DESC, "Checksum word 4") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 4, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:PROJ_CHECKSUM_calc") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:PROJ_CHECKSUM_calc") { field(INPA, "PLC:GUNB:PP02:w4 NPP MS") field(INPB, "PLC:GUNB:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:GUNB:PP02:PROJ_CHECKSUM PP MS") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:PROJ_CHECKSUM") { field(DESC, "Total Project Check Sum") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:GUNB:PP02:w5") { field(DESC, "Checksum word 5") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 5, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:DAY_MONTH_calc") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:DAY_MONTH_calc") { field(INPA, "PLC:GUNB:PP02:w5 NPP MS") field(INPB, "PLC:GUNB:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:GUNB:PP02:DAY_MONTH PP MS") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:DAY_MONTH") { field(DESC, "Raw day and month") field(ASG, "Internal") } record(calc, "PLC:GUNB:PP02:PROJ_MONTH") { field(DESC, "Project creation day") field(INPA, "PLC:GUNB:PP02:DAY_MONTH CP MS") field(CALC, "A & 0xFF") info(autosaveFields_pass0, "VAL") } record(calc, "PLC:GUNB:PP02:PROJ_DAY") { field(DESC, "Project creation month") field(INPA, "PLC:GUNB:PP02:DAY_MONTH CP MS") field(CALC, "A >> 8") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:GUNB:PP02:w6") { field(DESC, "Checksum word 6") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 6, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:PROJ_YEAR_calc") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:PROJ_YEAR_calc") { field(INPA, "PLC:GUNB:PP02:w6 NPP MS") field(INPB, "PLC:GUNB:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:GUNB:PP02:PROJ_YEAR PP MS") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:PROJ_YEAR") { field(DESC, "Project creation year.") info(autosaveFields_pass0, "VAL") } record(longin, "PLC:GUNB:PP02:w7") { field(DESC, "Checksum word 7") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 7, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:OP_HRS_MSB_calc") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:OP_HRS_MSB_calc") { field(INPA, "PLC:GUNB:PP02:w7 NPP MS") field(INPB, "PLC:GUNB:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:GUNB:PP02:OP_HRS_MSB PP MS") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:OP_HRS_MSB") { field(DESC, "Operation hours upper byte") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:w8") { field(DESC, "Checksum word 8") field(SCAN, "I/O Intr") field(DTYP, "asynUInt32Digital") field(INP, "@asynMask(GUNB_BSOIC_Wd, 8, 0xFFFF, 1)") field(FLNK, "PLC:GUNB:PP02:OP_HRS_LSB_calc") field(ASG, "Internal") } record(calcout, "PLC:GUNB:PP02:OP_HRS_LSB_calc") { field(INPA, "PLC:GUNB:PP02:w8 NPP MS") field(INPB, "PLC:GUNB:PP02:CHECKSUM_SDIS NPP MS") field(CALC, "B") field(OCAL, "A") field(DOPT, "Use OCAL") field(OOPT, "When Non-zero") field(OUT, "PLC:GUNB:PP02:OP_HRS_LSB PP MS") field(ASG, "Internal") } record(longin, "PLC:GUNB:PP02:OP_HRS_LSB") { field(DESC, "Operation hours lower byte") field(ASG, "Internal") } record(calc, "PLC:GUNB:PP02:OP_HOURS") { field(INPA, "PLC:GUNB:PP02:OP_HRS_MSB CP MS") field(INPB, "PLC:GUNB:PP02:OP_HRS_LSB CP MS") field(CALC, "(A << 8)+(B>>8)") info(autosaveFields_pass0, "VAL") } record(mbbi, "PLC:GUNB:PP02:BASE_MODEL") { field(DTYP, "Raw Soft Channel") field(NOBT, "8") field(INP, "PLC:GUNB:PP02:OP_HRS_LSB CP MS") field(ZRVL, "0x00") field(ONVL, "0x02") field(TWVL, "0x04") field(THVL, "0x03") field(FRVL, "0x20") field(FVVL, "0x22") field(SXVL, "0x24") field(SVVL, "0x23") field(EIVL, "0x50") field(NIVL, "0x51") field(TEVL, "0x52") field(ZRST, "PNOZ m1p") field(ONST, "PNOZ m0p") field(TWST, "PNOZ m2p") field(THST, "PNOZ m3p") field(FRST, "PNOZ m1p ETH") field(FVST, "PNOZ m0p ETH") field(SXST, "PNOZ m2p ETH") field(SVST, "PNOZ m3p ETH") field(EIST, "PNOZ mm0p") field(NIST, "PNOZ mm0.1p") field(TEST, "PNOZ mm0.2p") } # End of file # Template for I/O statistics record(bo,"PLC:GUNB:PP02:RDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(GUNB_BSOIC_Rd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:GUNB:PP02:RDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:GUNB:PP02:RDHist.PROC") } record(waveform,"PLC:GUNB:PP02:RDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(GUNB_BSOIC_Rd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:GUNB:PP02:RDHistTimeAxis.PROC") } record(waveform,"PLC:GUNB:PP02:RDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(GUNB_BSOIC_Rd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:GUNB:PP02:RDReadOK.PROC") } record(longout,"PLC:GUNB:PP02:RDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(GUNB_BSOIC_Rd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:GUNB:PP02:RDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Rd 0)READ_OK") field(FLNK,"PLC:GUNB:PP02:RDWriteOK.PROC") } record(longin,"PLC:GUNB:PP02:RDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Rd 0)WRITE_OK") field(FLNK,"PLC:GUNB:PP02:RDIOErrors.PROC") } record(longin,"PLC:GUNB:PP02:RDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Rd 0)IO_ERRORS") field(FLNK,"PLC:GUNB:PP02:RDLastIOTime.PROC") } record(longin,"PLC:GUNB:PP02:RDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Rd 0)LAST_IO_TIME") field(FLNK,"PLC:GUNB:PP02:RDMaxIOTime.PROC") } record(longin,"PLC:GUNB:PP02:RDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Rd 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:GUNB:PP02:WRTHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(GUNB_BSOIC_Wrt 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:GUNB:PP02:WRTStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:GUNB:PP02:WRTHist.PROC") } record(waveform,"PLC:GUNB:PP02:WRTHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:GUNB:PP02:WRTHistTimeAxis.PROC") } record(waveform,"PLC:GUNB:PP02:WRTHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:GUNB:PP02:WRTReadOK.PROC") } record(longout,"PLC:GUNB:PP02:WRTMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(GUNB_BSOIC_Wrt 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:GUNB:PP02:WRTReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)READ_OK") field(FLNK,"PLC:GUNB:PP02:WRTWriteOK.PROC") } record(longin,"PLC:GUNB:PP02:WRTWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)WRITE_OK") field(FLNK,"PLC:GUNB:PP02:WRTIOErrors.PROC") } record(longin,"PLC:GUNB:PP02:WRTIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)IO_ERRORS") field(FLNK,"PLC:GUNB:PP02:WRTLastIOTime.PROC") } record(longin,"PLC:GUNB:PP02:WRTLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)LAST_IO_TIME") field(FLNK,"PLC:GUNB:PP02:WRTMaxIOTime.PROC") } record(longin,"PLC:GUNB:PP02:WRTMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wrt 0)MAX_IO_TIME") } # Template for I/O statistics record(bo,"PLC:GUNB:PP02:WDHistEnable") { field(DTYP,"asynUInt32Digital") field(OUT,"@asynMask(GUNB_BSOIC_Wd 0 0xFFFF)ENABLE_HISTOGRAM") field(ZNAM,"Disable") field(ONAM,"Enable") } record(bo, "PLC:GUNB:PP02:WDStatistics") { field(SCAN, "10 second") field(FLNK, "PLC:GUNB:PP02:WDHist.PROC") } record(waveform,"PLC:GUNB:PP02:WDHist") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(GUNB_BSOIC_Wd 0)READ_HISTOGRAM") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:GUNB:PP02:WDHistTimeAxis.PROC") } record(waveform,"PLC:GUNB:PP02:WDHistTimeAxis") { field(DTYP,"asynInt32ArrayIn") field(INP,"@asyn(GUNB_BSOIC_Wd 0)HISTOGRAM_TIME_AXIS") field(FTVL,"LONG") field(NELM,"200") # This number should match driver field(FLNK,"PLC:GUNB:PP02:WDReadOK.PROC") } record(longout,"PLC:GUNB:PP02:WDMsPerBin") { field(DTYP,"asynInt32") field(OUT,"@asyn(GUNB_BSOIC_Wd 0)HISTOGRAM_BIN_TIME") field(DRVL,"0") field(VAL,"1") field(PINI,"1") } record(longin,"PLC:GUNB:PP02:WDReadOK") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wd 0)READ_OK") field(FLNK,"PLC:GUNB:PP02:WDWriteOK.PROC") } record(longin,"PLC:GUNB:PP02:WDWriteOK") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wd 0)WRITE_OK") field(FLNK,"PLC:GUNB:PP02:WDIOErrors.PROC") } record(longin,"PLC:GUNB:PP02:WDIOErrors") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wd 0)IO_ERRORS") field(FLNK,"PLC:GUNB:PP02:WDLastIOTime.PROC") } record(longin,"PLC:GUNB:PP02:WDLastIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wd 0)LAST_IO_TIME") field(FLNK,"PLC:GUNB:PP02:WDMaxIOTime.PROC") } record(longin,"PLC:GUNB:PP02:WDMaxIOTime") { field(DTYP,"asynInt32") field(INP,"@asyn(GUNB_BSOIC_Wd 0)MAX_IO_TIME") } record(bi, "PLC:LI00:1:S7_STATUS") { field(DTYP, "S7plc stat") field(INP, "@PLC_LI00_PP01") field(SCAN, "I/O Intr") field(ZNAM, "Disconnected") field(ONAM, "Connected") field(ZSV, "MAJOR") field(FLNK, "PLC:LI00:1:S7_STAT_COUNTER") } record(calc, "PLC:LI00:1:S7_STAT_COUNTER") { field(INPA, "PLC:LI00:1:S7_STAT_COUNTER") field(CALC, "A+1") field(FLNK, "PLC:LI00:1:S7_DISCONNECT_COUNTER") } record(calc, "PLC:LI00:1:S7_DISCONNECT_COUNTER") { field(INPA, "PLC:LI00:1:S7_STATUS") field(INPB, "PLC:LI00:1:S7_DISCONNECT_COUNTER.LA") field(INPC, "PLC:LI00:1:S7_DISCONNECT_COUNTER") field(CALC, "(A=0&&B=1)?C+1:C") } record(ai, "BSOC:GUNB:03:GAMMAPLC") { field(DESC, "Inj/LI00 BSOLNW03 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/118 T=WORD") field(PREC, "3") field(EGU, "V") field(EGUF, "10") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(LINR, "LINEAR") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:GUNB:03:GAMMARAW") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:GUNB:03:GAMMARAW") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "A*2.3725") field(INPA, "BSOC:GUNB:03:GAMMAPLC") field(PREC, "3") field(EGU, "V") field(HOPR, "10") field(HIHI, "9") field(HIGH, "8") field(LOW, "0.2") field(LOLO, "0.1") field(ADEL, "0") field(MDEL, "0") field(HHSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(LLSV, "MAJOR") field(FLNK, "BSOC:GUNB:03:GAMMAACT") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } record(calcout, "BSOC:GUNB:03:GAMMAACT") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(CALC, "B*(10^(A*0.6))") field(INPA, "BSOC:GUNB:03:GAMMARAW") field(INPB, "1.0") field(EGU, "mrem/hr") field(HOPR, "10") field(LOPR, "0") field(HIHI, "9") field(HIGH, "7") field(LOW, "1.5") field(LOLO, "0") field(ADEL, "0") field(HHSV, "MAJOR") field(LLSV, "MAJOR") field(HSV, "MINOR") field(LSV, "MINOR") field(PREC, "3") info(autosaveFields, "ADEL MDEL HIHI HHSV HIGH HSV LOW LSV LOLO LLSV") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:GUNB:03:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:GUNB:03:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:GUNB:03:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:GUNB:03:WARNINGMODE") field(INPB, "BSOC:GUNB:03:GAMMAACT.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:GUNB:03:WARNINGMODE",3440,3386,0,1,"BSOC:GUNB:03:WARNINGMODE") #! Field("BSOC:GUNB:03:WARNINGMODE.VAL",16777215,1,"BSOC:GUNB:03:WARNINGMODE.VAL") #! Field("BSOC:GUNB:03:WARNINGMODE.FLNK",16777215,1,"BSOC:GUNB:03:WARNINGMODE.FLNK") #! Link("BSOC:GUNB:03:WARNINGMODE.FLNK","BSOC:GUNB:03:CALCWARNING") #! Record("BSOC:GUNB:03:CALCWARNING",3760,3400,0,0,"BSOC:GUNB:03:CALCWARNING") #! Field("BSOC:GUNB:03:CALCWARNING.INPA",16777215,0,"BSOC:GUNB:03:CALCWARNING.INPA") #! Link("BSOC:GUNB:03:CALCWARNING.INPA","BSOC:GUNB:03:WARNINGMODE.VAL") #! Field("BSOC:GUNB:03:CALCWARNING.INPB",16777215,1,"BSOC:GUNB:03:CALCWARNING.INPB") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../dbd/ppsIoc.dbd") #! DBDEND record(bi, "BSOC:GUNB:04N:WARNINGMODE") { field(DESC, "Warning bypass stat") field(PINI, "YES") field(OSV, "MINOR") field(ZNAM, "Active") field(ONAM, "Bypass") field(VAL, "0") field(FLNK, "BSOC:GUNB:04N:CALCWARNING") field(ASG, "MCC") info(autosaveFields_pass0, "VAL") } record(calcout, "BSOC:GUNB:04N:CALCWARNING") { field(CALC, "(!A)*B") field(INPA, "BSOC:GUNB:04N:WARNINGMODE") field(INPB, "BSOC:GUNB:04N:COM:NeutronDoseRate.SEVR") field(HIGH, "1") field(HIHI, "2") field(HSV, "MINOR") field(HHSV, "MAJOR") field(SCAN, "2 second") } #! Further lines contain data used by VisualDCT #! View(3250,3365,1.0) #! Record("BSOC:GUNB:04N:WARNINGMODE",3440,3386,0,1,"BSOC:GUNB:04N:WARNINGMODE") #! Field("BSOC:GUNB:04N:WARNINGMODE.VAL",16777215,1,"BSOC:GUNB:04N:WARNINGMODE.VAL") #! Field("BSOC:GUNB:04N:WARNINGMODE.FLNK",16777215,1,"BSOC:GUNB:04N:WARNINGMODE.FLNK") #! Link("BSOC:GUNB:04N:WARNINGMODE.FLNK","BSOC:GUNB:04N:CALCWARNING") #! Record("BSOC:GUNB:04N:CALCWARNING",3760,3400,0,0,"BSOC:GUNB:04N:CALCWARNING") #! Field("BSOC:GUNB:04N:CALCWARNING.INPA",16777215,0,"BSOC:GUNB:04N:CALCWARNING.INPA") #! Link("BSOC:GUNB:04N:CALCWARNING.INPA","BSOC:GUNB:04N:WARNINGMODE.VAL") #! Field("BSOC:GUNB:04N:CALCWARNING.INPB",16777215,1,"BSOC:GUNB:04N:CALCWARNING.INPB") record(longin, "RADM:LI00:1:DoseRate") { field(DESC, "Inj/LI00 RDM #1 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/126 T=WORD") } record(longin, "RADM:LI00:2:DoseRate") { field(DESC, "Inj/LI00 RDM #2 Analog") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/128 T=WORD") } record(longin, "PPS:LI00:1:SearchTimer") { field(DESC, "Inj/LI00 Search Timer: (units?)") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/144 T=WORD") } record(longin, "PPS:LI00:1:BeamImminentTimer") { field(DESC, "Inj/LI00 Beam Imminent AV Warn time sec") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/146 T=BYTE") } record(bi, "PLC:LI00:1:TestMode") { field(DESC, "Inj/LI00 In TEST Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=0") field(ZNAM, "Test") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:1:DC:Ok") { field(DESC, "Inj/LI00 24VDC-PS DC Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:1:DC:UpsFaultStatus") { field(DESC, "Inj/LI00 DC UPS Alarm") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:1:DC:UpsMode") { field(DESC, "Inj/LI00 DC UPS in Battery Mode") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=4") field(ZNAM, "Normal") field(ONAM, "Battery") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI00:1:DC:UpsCharging") { field(DESC, "Inj/LI00 DC UPS Battery Charging") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=5") field(ZNAM, "Charged") field(ONAM, "Charging") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PLC:LI00:1:ZoneSwitchFault") { field(DESC, "Inj/LI00 Zone Network Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:1:ChainASwitchFault") { field(DESC, "Inj/LI00 Chain-A Safety Net Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/134 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:1:ChainBSwitchFault") { field(DESC, "Inj/LI00 Chain-B Safety Net Switch Fault") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/135 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:Locked") { field(DESC, "Inj Chicane Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/135 T=BYTE B=1") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:Locked") { field(DESC, "S0 MW Door Maglock Locked") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/135 T=BYTE B=2") field(ZNAM, "Not_Locked") field(ONAM, "Locked") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AvLitContA") { field(DESC, "S0 Lighting contactor A feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/135 T=BYTE B=5") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AvLitContB") { field(DESC, "S0 Lighting contactor B feedback") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/135 T=BYTE B=6") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AudioPlay") { field(DESC, "Inj/LI00 TOA EV-20R message playing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/135 T=BYTE B=7") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AllZoneClear") { field(DESC, "Inj/LI00 All zone CLEAR summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "ODM:LI00:1:Sumy") { field(DESC, "Inj/LI00 ODM Sum Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=1") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI00:1:Sumy") { field(DESC, "Inj/LI00 RDM Ok Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=2") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AllZoneHazOff") { field(DESC, "Inj/LI00 All zones All Hazards off Summy") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=3") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AllKeybank") { field(DESC, "Inj/LI00 All Kbnk Cplt Sum") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=4") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:SYSW:2:Off") { field(DESC, "Inj/LI00 West Global is in OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=5") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:SYSW:2:ZoneEntry") { field(DESC, "Inj/LI00 West Glbl in Zone Entry Enabled") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=6") field(ZNAM, "Entry_Not_Set") field(ONAM, "Entry_Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:SYSW:2:BeamReady") { field(DESC, "Inj/LI00 West Gbl in Rdy for Beam") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/136 T=BYTE B=7") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:FanKeyswitch") { field(DESC, "S0 LINAC fan KeySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetPr0W") { field(DESC, "Preset PR-0W ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=1") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetPr0E") { field(DESC, "Preset PR-0E ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=2") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EnableKeyswitch") { field(DESC, "Gun En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=3") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EnableKeyswitch") { field(DESC, "Inj/LI00 RF En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=4") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:EnableKeyswitch") { field(DESC, "TCAV En/DIS Keyswitch Status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=5") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI00:1:Fault") { field(DESC, "Inj/LI00 Local RDM Ok 1") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI00:2:Fault") { field(DESC, "Inj/LI00 Local RDM Ok 2") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/137 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "RADM:LI00:1:BypKeyswitch") { field(DESC, "Inj/LI00 RA RDM Bypass KeySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/138 T=BYTE B=0") field(ZNAM, "Normal") field(ONAM, "Override") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "ODM:LI00:1:BypKeyswitch") { field(DESC, "Inj/LI00 ODM Bypass keySW status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/138 T=BYTE B=1") field(ZNAM, "Normal") field(ONAM, "Override") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:1:MwFanCont") { field(DESC, "S0 MW fan contactor feedback status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/138 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwFanSwitch") { field(DESC, "S0 MW fan safety switches fdbk status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/138 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwFanInhibit") { field(DESC, "Inhibit S0 MW fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/138 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LinacFanInhibit") { field(DESC, "S0 Inhibit LINAC Exhaust Fan") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/138 T=BYTE B=5") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LinacFanCurrent") { field(DESC, "S0 LINAC Exhaust Fan motor current Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=0") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LinacFanSsFbOk") { field(DESC, "S0 LINAC Exhaust Fan safety sw fdbck Ok") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=1") field(ZNAM, "Not_Ok") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:YmYellow") { field(DESC, "Inj/LI00 Y/M Light Yellow") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:YmMagenta") { field(DESC, "Inj/LI00 Y/M Light Magenta") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PermAccess") { field(DESC, "Inj/LI00 Zone in Permitted Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=4") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:CtrlAccess") { field(DESC, "Inj/LI00 Zone in Controlled Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:RestAccess") { field(DESC, "Inj/LI00 Zone in Restricted Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:NoAccess") { field(DESC, "Inj/LI00 Zone in No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/139 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:MaglockOn") { field(DESC, "Inj Chicane Door Magnlock ON") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/140 T=BYTE B=0") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "DOOR:LI00:1:MaglockOn") { field(DESC, "S0 MW Door Magnalock Inhibit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/140 T=BYTE B=1") field(ZNAM, "On") field(ONAM, "Off") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:1:AcPlcHeartbeat") { field(DESC, "Inj/LI00 PLC Heartbeat AC_PLC Pulse Srce") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/140 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LlrfPmtIntrtd") { field(DESC, "Inj/LI00 LLRF Permit interrupted") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/140 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:Lockout") { field(DESC, "Inj/LI00 Door Lockout") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/140 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:AllDoorGateClsd") { field(DESC, "Inj/LI00 All RT perim Drs & Gates Clsd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/141 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:HbA") { field(DESC, "Inj/LI00 Safety Intlk PLC Ch-A HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/141 T=BYTE B=1") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:HbB") { field(DESC, "Inj/LI00 Safety Intlk PLC Ch-B HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/141 T=BYTE B=2") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:HbA") { field(DESC, "Inj/LI00 Stopper Ctrl PLC Ch-A HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/141 T=BYTE B=3") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:HbB") { field(DESC, "Inj/LI00 Stopper Ctrl PLC Ch-B HB flt") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/141 T=BYTE B=4") field(ZNAM, "Ok") field(ONAM, "Fault") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "ODM:LI00:1:PowerLoss") { field(DESC, "Inj/LI00 ODM Power Loss Detect Relay") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/141 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bo, "DOOR:GUNB:1:Release") { field(DESC, "Inj Chicane Door ACR Remote DIB") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/101 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "DOOR:LI00:1:Release") { field(DESC, "S0 MW Door ACR Remote DIB") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/101 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:InterlockReset") { field(DESC, "Inj/LI00 Reset Interlocks") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/101 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqSearchReset") { field(DESC, "Inj/LI00 ACR Remote Reset Search") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/101 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqIntSearch") { field(DESC, "Inj/LI00 Interrupt Preserved Search") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/101 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI00:1:ReqSuspIntHrtbt") { field(DESC, "Inj/LI00 Pause PLC Heartbeat Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/102 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI00:3:ReqSuspStpHrtbt") { field(DESC, "Inj/LI00 Soft Pause Stopper A/B PLC HeB") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/103 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:GUNB:100:StpFAC-ISAPmtOn") { field(DESC, "Req Turn on Inj/LI00 Gun SSA (FAC-ISA)") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/103 T=BYTE B=7") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:GUNB:100:StpFAC-ISAPmtOff") { field(DESC, "Req Turn off Inj/LI00 Gun SSA (FAC-ISA)") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/104 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L0B:100:StpFAC-IS2PmtOn") { field(DESC, "Req Inj/LI00 RF & Buncher (FAC-IS2) on") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/104 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "SSA:L0B:100:StpFAC-IS2PmtOff") { field(DESC, "Req Inj/LI00 RF & Buncher (FAC-IS2) off") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/104 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "KLYS:DIAG0:1:StpTCavPmtOn") { field(DESC, "Req Turn on Inj/LI00 RF TCAV") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/104 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "KLYS:DIAG0:1:StpTCavPmtOff") { field(DESC, "Req Turn off Inj/LI00 RF TCAV") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/104 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqPermAccess") { field(DESC, "Inj/LI00 Bail to P/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/105 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqCtrlAccess") { field(DESC, "Inj/LI00 Bail to C/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/105 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqRestAccess") { field(DESC, "Inj/LI00 Bail to R/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/105 T=BYTE B=2") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqNoAccess") { field(DESC, "Inj/LI00 Bail to N/A Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/105 T=BYTE B=3") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:GUNB:1:KeybankRelease") { field(DESC, "Inj Chicane KB1 Release to AC") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/105 T=BYTE B=6") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:KeybankRelease") { field(DESC, "S0 MW KB1 Release to AC") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/106 T=BYTE B=0") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:2:KeybankRelease") { field(DESC, "S0 MW KB2 Release to AC") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/106 T=BYTE B=1") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqOpnHatch") { field(DESC, "S0 MW Hatch Open Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/106 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PPS:LI00:1:ReqClsHatch") { field(DESC, "S0 MW Hatch Closed Request") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/106 T=BYTE B=5") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bo, "PLC:LI00:1:ClearHBFault") { field(DESC, "Inj/LI00 Clear HB Fault Warning") field(DTYP, "S7plc") field(OUT, "@PLC_LI00_PP01/109 T=BYTE B=4") field(ZNAM, "False") field(ONAM, "True") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") field(PINI, "YES") field(ASG, "") info(autosaveFields, "VAL") } record(bi, "DOOR:GUNB:1:Closed") { field(DESC, "RT-IN Inj Chicane Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:Gate") { field(DESC, "RT-IN Inj Chicane Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:Keybank") { field(DESC, "RT-IN Inj Chicane KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:EExit") { field(DESC, "RT-IN Inj Chicane Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:Closed") { field(DESC, "RT-IN S0 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:Hatch") { field(DESC, "RT-IN S0 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:Keybank") { field(DESC, "RT-IN S0 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:Keybank") { field(DESC, "RT-IN S0 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/56 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:EExit") { field(DESC, "RT-IN S0 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:2:Closed") { field(DESC, "RT-IN S0 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:Gate") { field(DESC, "RT-IN LI00/01 Housing Bndry Gate Clsd LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EExit") { field(DESC, "RT-IN LI00/01 Housing Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EOString") { field(DESC, "RT-IN Inj Chicane EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwEOString") { field(DESC, "RT-IN S0 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOString") { field(DESC, "RT-IN Inj/S0 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:Preset") { field(DESC, "RT-IN S0 MW Preserved Preset ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/57 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:2:Preset") { field(DESC, "RT-IN S0 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/58 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:1:YmOverrdStat") { field(DESC, "RT-IN Inj/LI00 Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/58 T=BYTE B=1") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:SearchReset") { field(DESC, "RT-IN LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/58 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:XInterlockIn") { field(DESC, "RT-IN Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/58 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LocSearchReset") { field(DESC, "RT-IN Search Reset Local") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/58 T=BYTE B=5") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:OFAULT") { field(DESC, "Pilz_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/59 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:IFAULT") { field(DESC, "Pilz_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/59 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:FAULT") { field(DESC, "Pilz_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/59 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:DIAG") { field(DESC, "Pilz_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/59 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:RUN") { field(DESC, "Pilz_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/59 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:COMM") { field(DESC, "Pilz_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/59 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:ClosedLatch") { field(DESC, "LAT Inj Chicane Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:GateLatch") { field(DESC, "LAT Inj Chicane Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:KeybankLatch") { field(DESC, "LAT Inj Chicane KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:EExitLatch") { field(DESC, "LAT Inj Chicane Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:ClosedLatch") { field(DESC, "LAT S0 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:HatchLatch") { field(DESC, "LAT S0 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:KeybankLatch") { field(DESC, "LAT S0 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:KeybankLatch") { field(DESC, "LAT S0 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/64 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:EExitLatch") { field(DESC, "LAT S0 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:2:ClosedLatch") { field(DESC, "LAT S0 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:GateLatch") { field(DESC, "LAT Inj/LI00 Housing Bndry Gate Clsd LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EExitLatch") { field(DESC, "LAT Inj/LI00 Housing Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EOStringLatch") { field(DESC, "LAT Inj Chicane EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwEOStringLatch") { field(DESC, "LAT S0 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOStringLatch") { field(DESC, "LAT Inj-S0 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/65 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:XRadReady") { field(DESC, "RT-OUT Inj/LI00 Rad Ready Cross-interlck") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/66 T=BYTE B=6") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneIntact") { field(DESC, "RT-OUT Inj/LI00 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/66 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneClear") { field(DESC, "RT-OUT Inj/LI00 Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/67 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneRadReady") { field(DESC, "RT-OUT Inj/LI00 Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/67 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PlayAudio") { field(DESC, "RT-OUT Inj/LI00 Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/67 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:SearchResetOut") { field(DESC, "RT-OUT Inj/LI00 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/67 T=BYTE B=3") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetSet") { field(DESC, "S0 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/68 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:PresetSet") { field(DESC, "S0 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/68 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresSearch") { field(DESC, "S0 MW/AOR) Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/68 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresSearchTimer") { field(DESC, "S0 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI00:1:ZoneKeybanks") { field(DESC, "Inj/LI00 Zone Local Keybanks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=1") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneNoAccess") { field(DESC, "Inj/LI00 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=2") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneInterlock") { field(DESC, "Inj/LI00 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:BeamImminentTiming") { field(DESC, "Inj/LI00 Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI00:1:BeamImminentTimeCplt") { field(DESC, "Inj/LI00 Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:CommHeartbeat") { field(DESC, "Inj/LI00 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOSumyLatch") { field(DESC, "Inj/LI00 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/69 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:OFAULT") { field(DESC, "Pilz_3_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/175 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:IFAULT") { field(DESC, "Pilz_3_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/175 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:FAULT") { field(DESC, "Pilz_3_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/175 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:DIAG") { field(DESC, "Pilz_3_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/175 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:RUN") { field(DESC, "Pilz_3_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/175 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:COMM") { field(DESC, "Pilz_3_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/175 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:PlcHeartbeat") { field(DESC, "Inj/LI00 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/182 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:CommHeartbeat") { field(DESC, "Inj/LI00 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/182 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI00:1:Sumy") { field(DESC, "Inj/LI00 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/182 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpPermit") { field(DESC, "LI00 Gun SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=1") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI00:1:StpPermit") { field(DESC, "LI00 RF & Buncher SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpPermit") { field(DESC, "LI00 RF TCAV Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=3") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:XInterlockIn") { field(DESC, "Inj/LI00 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpEnable") { field(DESC, "Inj/LI00 Gun SSA Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI00:1:StpEnable") { field(DESC, "Inj/LI00 RF & Buncher Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpEnable") { field(DESC, "Inj/LI00 RF TCAV Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/183 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpFAC-ISAClsCmd") { field(DESC, "Inj/LI00 Gun SSA (FAC-ISA) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/184 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L0B:1:StpFAC-IS2ClsCmd") { field(DESC, "Inj/LI00 RF/Bnch SSA (FAC-IS2) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/184 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpTCavClsCmd") { field(DESC, "Inj/LI00 RF TCAV Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/184 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpFAC-ISAIsOff") { field(DESC, "Inj/LI00 Gun SSA (FAC-ISA) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/185 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L0B:1:StpFAC-IS2IsOff") { field(DESC, "Inj/LI00 RF & Buncher (FAC-IS2) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/185 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "KLYS:DIAG0:1:StpTCavOff") { field(DESC, "Inj/LI00 RF TCAV OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/185 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:ClosedA") { field(DESC, "RT-IN Inj Chicane Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:GateA") { field(DESC, "RT-IN Inj Chicane Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:KeybankA") { field(DESC, "RT-IN Inj Chicane KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:EExitA") { field(DESC, "RT-IN Inj Chicane Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:ClosedA") { field(DESC, "RT-IN S0 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:HatchA") { field(DESC, "RT-IN S0 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:KeybankA") { field(DESC, "RT-IN S0 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:KeybankA") { field(DESC, "RT-IN S0 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/74 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:EExitA") { field(DESC, "RT-IN S0 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:2:ClosedA") { field(DESC, "RT-IN S0 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:GateA") { field(DESC, "RT-IN LI00/01 Housing Bndry Gate Clsd LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EExitA") { field(DESC, "RT-IN LI00/01 Housing Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EOStringA") { field(DESC, "RT-IN Inj Chicane EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwEOStringA") { field(DESC, "RT-IN S0 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOStringA") { field(DESC, "RT-IN Inj/S0 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetA") { field(DESC, "RT-IN S0 MW Preserved Preset ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/75 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:2:PresetA") { field(DESC, "RT-IN S0 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/76 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:1:YmOverrdStatA") { field(DESC, "RT-IN Inj/LI00 Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/76 T=BYTE B=1") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:SearchResetA") { field(DESC, "RT-IN LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/76 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:XInterlockInA") { field(DESC, "RT-IN Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/76 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LocSearchResetA") { field(DESC, "RT-IN Search Reset Local") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/76 T=BYTE B=5") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:OFAULTA") { field(DESC, "PilzA_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/77 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:IFAULTA") { field(DESC, "PilzA_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/77 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:FAULTA") { field(DESC, "PilzA_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/77 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:DIAGA") { field(DESC, "PilzA_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/77 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:RUNA") { field(DESC, "PilzA_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/77 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:COMMA") { field(DESC, "PilzA_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/77 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:ClosedLatchA") { field(DESC, "LAT Inj Chicane Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:GateLatchA") { field(DESC, "LAT Inj Chicane Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:KeybankLatchA") { field(DESC, "LAT Inj Chicane KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:EExitLatchA") { field(DESC, "LAT Inj Chicane Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:ClosedLatchA") { field(DESC, "LAT S0 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:HatchLatchA") { field(DESC, "LAT S0 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:KeybankLatchA") { field(DESC, "LAT S0 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:KeybankLatchA") { field(DESC, "LAT S0 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/82 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:EExitLatchA") { field(DESC, "LAT S0 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:2:ClosedLatchA") { field(DESC, "LAT S0 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:GateLatchA") { field(DESC, "LAT Inj/LI00 Housing Bndry Gate Clsd LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EExitLatchA") { field(DESC, "LAT Inj/LI00 Housing Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EOStringLatchA") { field(DESC, "LAT Inj Chicane EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwEOStringLatchA") { field(DESC, "LAT S0 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOStringLatchA") { field(DESC, "LAT Inj-S0 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/83 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:XRadReadyA") { field(DESC, "RT-OUT Inj/LI00 Rad Ready Cross-interlck") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/84 T=BYTE B=6") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneIntactA") { field(DESC, "RT-OUT Inj/LI00 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/84 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneClearA") { field(DESC, "RT-OUT Inj/LI00 Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/85 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneRadReadyA") { field(DESC, "RT-OUT Inj/LI00 Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/85 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PlayAudioA") { field(DESC, "RT-OUT Inj/LI00 Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/85 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:SearchResetOutA") { field(DESC, "RT-OUT Inj/LI00 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/85 T=BYTE B=3") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetSetA") { field(DESC, "S0 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/86 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:PresetSetA") { field(DESC, "S0 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/86 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresSearchA") { field(DESC, "S0 MW/AOR) Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/86 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresSearchTimerA") { field(DESC, "S0 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI00:1:ZoneKeybanksA") { field(DESC, "Inj/LI00 Zone Local Keybanks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=1") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneNoAccessA") { field(DESC, "Inj/LI00 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=2") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneInterlockA") { field(DESC, "Inj/LI00 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:BeamImminentTimingA") { field(DESC, "Inj/LI00 Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI00:1:BeamImminentTimeCpltA") { field(DESC, "Inj/LI00 Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:CommHeartbeatA") { field(DESC, "Inj/LI00 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOSumyLatchA") { field(DESC, "Inj/LI00 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/87 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:OFAULTA") { field(DESC, "Pilz_3A_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/193 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:IFAULTA") { field(DESC, "Pilz_3A_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/193 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:FAULTA") { field(DESC, "Pilz_3A_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/193 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:DIAGA") { field(DESC, "Pilz_3A_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/193 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:RUNA") { field(DESC, "Pilz_3A_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/193 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:COMMA") { field(DESC, "Pilz_3A_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/193 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:PlcHeartbeatA") { field(DESC, "Inj/LI00 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/200 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:CommHeartbeatA") { field(DESC, "Inj/LI00 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/200 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI00:1:SumyA") { field(DESC, "Inj/LI00 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/200 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpPermitA") { field(DESC, "LI00 Gun SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=1") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI00:1:StpPermitA") { field(DESC, "LI00 RF & Buncher SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpPermitA") { field(DESC, "LI00 RF TCAV Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=3") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:XInterlockInA") { field(DESC, "Inj/LI00 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpEnableA") { field(DESC, "Inj/LI00 Gun SSA Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI00:1:StpEnableA") { field(DESC, "Inj/LI00 RF & Buncher Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpEnableA") { field(DESC, "Inj/LI00 RF TCAV Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/201 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpFAC-ISAClsCmdA") { field(DESC, "Inj/LI00 Gun SSA (FAC-ISA) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/202 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L0B:1:StpFAC-IS2ClsCmdA") { field(DESC, "Inj/LI00 RF/Bnch SSA (FAC-IS2) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/202 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpTCavClsCmdA") { field(DESC, "Inj/LI00 RF TCAV Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/202 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpFAC-ISAIsOffA") { field(DESC, "Inj/LI00 Gun SSA (FAC-ISA) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/203 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L0B:1:StpFAC-IS2IsOffA") { field(DESC, "Inj/LI00 RF & Buncher (FAC-IS2) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/203 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "KLYS:DIAG0:1:StpTCavOffA") { field(DESC, "Inj/LI00 RF TCAV OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/203 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:ClosedB") { field(DESC, "RT-IN Inj Chicane Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=0") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:GateB") { field(DESC, "RT-IN Inj Chicane Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:KeybankB") { field(DESC, "RT-IN Inj Chicane KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=2") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:EExitB") { field(DESC, "RT-IN Inj Chicane Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:ClosedB") { field(DESC, "RT-IN S0 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=4") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:HatchB") { field(DESC, "RT-IN S0 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=5") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:KeybankB") { field(DESC, "RT-IN S0 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=6") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:KeybankB") { field(DESC, "RT-IN S0 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/92 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:EExitB") { field(DESC, "RT-IN S0 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=0") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:2:ClosedB") { field(DESC, "RT-IN S0 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=1") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:GateB") { field(DESC, "RT-IN LI00/01 Housing Bndry Gate Clsd LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=2") field(ZNAM, "Not_Closed") field(ONAM, "Closed") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EExitB") { field(DESC, "RT-IN LI00/01 Housing Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=3") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EOStringB") { field(DESC, "RT-IN Inj Chicane EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=4") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwEOStringB") { field(DESC, "RT-IN S0 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOStringB") { field(DESC, "RT-IN Inj/S0 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetB") { field(DESC, "RT-IN S0 MW Preserved Preset ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/93 T=BYTE B=7") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:2:PresetB") { field(DESC, "RT-IN S0 AOR Preserved Preset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/94 T=BYTE B=0") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PPS:LI00:1:YmOverrdStatB") { field(DESC, "RT-IN Inj/LI00 Y/M Light Override status") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/94 T=BYTE B=1") field(ZNAM, "Overridden") field(ONAM, "Normal") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI01:2:SearchResetB") { field(DESC, "RT-IN LI01-07 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/94 T=BYTE B=2") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:XInterlockInB") { field(DESC, "RT-IN Cross-interlock Input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/94 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:LocSearchResetB") { field(DESC, "RT-IN Search Reset Local") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/94 T=BYTE B=5") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:OFAULTB") { field(DESC, "PilzB_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/95 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:IFAULTB") { field(DESC, "PilzB_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/95 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:FAULTB") { field(DESC, "PilzB_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/95 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:2:DIAGB") { field(DESC, "PilzB_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/95 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:RUNB") { field(DESC, "PilzB_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/95 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:COMMB") { field(DESC, "PilzB_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/95 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:ClosedLatchB") { field(DESC, "LAT Inj Chicane Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:GateLatchB") { field(DESC, "LAT Inj Chicane Gate Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:KeybankLatchB") { field(DESC, "LAT Inj Chicane KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:GUNB:1:EExitLatchB") { field(DESC, "LAT Inj Chicane Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:ClosedLatchB") { field(DESC, "LAT S0 MW Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:HatchLatchB") { field(DESC, "LAT S0 MW Hatch Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:KeybankLatchB") { field(DESC, "LAT S0 MW KB1 Complete ") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:KeybankLatchB") { field(DESC, "LAT S0 MW KB2 Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/100 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:1:EExitLatchB") { field(DESC, "LAT S0 MW Door E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=0") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "DOOR:LI00:2:ClosedLatchB") { field(DESC, "LAT S0 AOR Door Closed LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=1") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:GateLatchB") { field(DESC, "LAT Inj/LI00 Housing Bndry Gate Clsd LS") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=2") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EExitLatchB") { field(DESC, "LAT Inj/LI00 Housing Bndry Gate E/E OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=3") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:GUNB:1:EOStringLatchB") { field(DESC, "LAT Inj Chicane EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=4") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:MwEOStringLatchB") { field(DESC, "LAT S0 MW EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=5") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOStringLatchB") { field(DESC, "LAT Inj-S0 Housing EO String OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/101 T=BYTE B=6") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:XRadReadyB") { field(DESC, "RT-OUT Inj/LI00 Rad Ready Cross-interlck") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/102 T=BYTE B=6") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneIntactB") { field(DESC, "RT-OUT Inj/LI00 Zone Intact") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/102 T=BYTE B=7") field(ZNAM, "Not_Intact") field(ONAM, "Intact") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneClearB") { field(DESC, "RT-OUT Inj/LI00 Zone Clear") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/103 T=BYTE B=0") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneRadReadyB") { field(DESC, "RT-OUT Inj/LI00 Zone Rad Ready") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/103 T=BYTE B=1") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PlayAudioB") { field(DESC, "RT-OUT Inj/LI00 Play Aud- beam imnt wrn") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/103 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:SearchResetOutB") { field(DESC, "RT-OUT Inj/LI00 Search is Reset") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/103 T=BYTE B=3") field(ZNAM, "Not_Reset") field(ONAM, "Reset") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresetSetB") { field(DESC, "S0 Alcove Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/104 T=BYTE B=5") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:2:PresetSetB") { field(DESC, "S0 AOR Preserved Preset is SET") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/104 T=BYTE B=6") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresSearchB") { field(DESC, "S0 MW/AOR) Preserved Search is Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/104 T=BYTE B=7") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:PresSearchTimerB") { field(DESC, "S0 Preserved Search Timer timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=0") field(ZNAM, "Not_Timing") field(ONAM, "Timing") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI00:1:ZoneKeybanksB") { field(DESC, "Inj/LI00 Zone Local Keybanks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=1") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneNoAccessB") { field(DESC, "Inj/LI00 Zone Ready for No Access") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=2") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:ZoneInterlockB") { field(DESC, "Inj/LI00 Zone Interlocks Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=3") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:BeamImminentTimingB") { field(DESC, "Inj/LI00 Beam Imnnt Tmr timing") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MINOR") } record(bi, "PPS:LI00:1:BeamImminentTimeCpltB") { field(DESC, "Inj/LI00 Beam Imnnt Tmr Complete") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=5") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:2:CommHeartbeatB") { field(DESC, "Inj/LI00 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:EOSumyLatchB") { field(DESC, "Inj/LI00 EO Strings OK Latch Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/105 T=BYTE B=7") field(ZNAM, "Not_Latched") field(ONAM, "Latched") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:OFAULTB") { field(DESC, "Pilz_3B_OFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/211 T=BYTE B=0") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:IFAULTB") { field(DESC, "Pilz_3B_IFAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/211 T=BYTE B=1") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:FAULTB") { field(DESC, "Pilz_3B_FAULT_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/211 T=BYTE B=2") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "PLC:LI00:3:DIAGB") { field(DESC, "Pilz_3B_DIAG_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/211 T=BYTE B=3") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:RUNB") { field(DESC, "Pilz_3B_RUN_lit") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/211 T=BYTE B=4") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:COMMB") { field(DESC, "Pilz_3B_Comm_OK") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/211 T=BYTE B=5") field(ZNAM, "None") field(ONAM, "Active") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:PlcHeartbeatB") { field(DESC, "Inj/LI00 PLC heartbeat") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/218 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:3:CommHeartbeatB") { field(DESC, "Inj/LI00 Comm heartbeat OUT") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/218 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "STPR:LI00:1:SumyB") { field(DESC, "Inj/LI00 All Stoppers IN/OFF Summary") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/218 T=BYTE B=7") field(ZNAM, "Not_off") field(ONAM, "All_off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpPermitB") { field(DESC, "LI00 Gun SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=1") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI00:1:StpPermitB") { field(DESC, "LI00 RF & Buncher SSA Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=2") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpPermitB") { field(DESC, "LI00 RF TCAV Permit from LW") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=3") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PPS:LI00:1:XInterlockInB") { field(DESC, "Inj/LI00 Cross-Interlock input") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=4") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpEnableB") { field(DESC, "Inj/LI00 Gun SSA Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=5") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:LI00:1:StpEnableB") { field(DESC, "Inj/LI00 RF & Buncher Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=6") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpEnableB") { field(DESC, "Inj/LI00 RF TCAV Stopper Enable") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/219 T=BYTE B=7") field(ZNAM, "Fault") field(ONAM, "OK") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpFAC-ISAClsCmdB") { field(DESC, "Inj/LI00 Gun SSA (FAC-ISA) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/220 T=BYTE B=0") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:L0B:1:StpFAC-IS2ClsCmdB") { field(DESC, "Inj/LI00 RF/Bnch SSA (FAC-IS2) Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/220 T=BYTE B=1") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "KLYS:DIAG0:1:StpTCavClsCmdB") { field(DESC, "Inj/LI00 RF TCAV Contactor Cmd") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/220 T=BYTE B=2") field(ZNAM, "Open") field(ONAM, "Close") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "SSA:GUNB:1:StpFAC-ISAIsOffB") { field(DESC, "Inj/LI00 Gun SSA (FAC-ISA) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/221 T=BYTE B=0") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "SSA:L0B:1:StpFAC-IS2IsOffB") { field(DESC, "Inj/LI00 RF & Buncher (FAC-IS2) OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/221 T=BYTE B=1") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } record(bi, "KLYS:DIAG0:1:StpTCavOffB") { field(DESC, "Inj/LI00 RF TCAV OFF") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/221 T=BYTE B=2") field(ZNAM, "Closed") field(ONAM, "Open") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(bi, "PLC:LI00:1:SafetyMode") { field(DESC, "AC_PLC Safety Mode. 1 = Deactivated") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/31 T=BYTE B=0") field(ZNAM, "Activated") field(ONAM, "Deactivated") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } record(longin, "PLC:LI00:1:SAFETY_SIG") { field(DESC, "Safety_Signature") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/20 T=DWORD") } record(longin, "PLC:LI00:2A:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2A_Int_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/24 T=WORD") } record(longin, "PLC:LI00:2B:PILZ_INT_CHECKSUM") { field(DESC, "Pilz_2B_Int_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/28 T=WORD") } record(longin, "PLC:LI00:1:COMPILE_DT_YEAR") { field(DESC, "Compile_Yr") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/32 T=BYTE") } record(longin, "PLC:LI00:1:COMPILE_DT_MONTH") { field(DESC, "Compile_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/33 T=BYTE") } record(longin, "PLC:LI00:1:COMPILE_DT_DAY") { field(DESC, "Compile_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/34 T=BYTE") } record(longin, "PLC:LI00:1:COMPILE_DT_HOUR") { field(DESC, "Compile_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/35 T=BYTE") } record(longin, "PLC:LI00:1:COMPILE_DT_MINUTE") { field(DESC, "Compile_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/36 T=BYTE") } record(longin, "PLC:LI00:1:COMPILE_DT_SECOND") { field(DESC, "Compile_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/37 T=BYTE") } record(longin, "PLC:LI00:1:OB100_DT_YEAR") { field(DESC, "Warm_Restart_Year") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/38 T=BYTE") } record(longin, "PLC:LI00:1:OB100_DT_MONTH") { field(DESC, "Warm_Restart_Month") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/39 T=BYTE") } record(longin, "PLC:LI00:1:OB100_DT_DAY") { field(DESC, "Warm_Restart_Day") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/40 T=BYTE") } record(longin, "PLC:LI00:1:OB100_DT_HOUR") { field(DESC, "Warm_Restart_Hour") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/41 T=BYTE") } record(longin, "PLC:LI00:1:OB100_DT_MINUTE") { field(DESC, "Warm_Restart_Minute") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/42 T=BYTE") } record(longin, "PLC:LI00:1:OB100_DT_SECOND") { field(DESC, "Warm_Restart_Second") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/43 T=BYTE") } record(longin, "PLC:LI00:2A:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2A_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/44 T=WORD") } record(longin, "PLC:LI00:2B:PILZ_INT_FLT_CNT") { field(DESC, "Pilz_2B_Int_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/46 T=WORD") } record(longin, "PLC:LI00:3A:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3A_Stop_Checksum_A") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/158 T=WORD") } record(longin, "PLC:LI00:3B:PILZ_STP_CHECKSUM") { field(DESC, "Pilz_3B_Stop_Checksum_B") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/162 T=WORD") } record(longin, "PLC:LI00:3A:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3A_Stop_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/166 T=WORD") } record(longin, "PLC:LI00:3B:PILZ_STP_FLT_CNT") { field(DESC, "Pilz_3B_Stop_Fault_Count") field(SCAN, "I/O Intr") field(DTYP, "S7plc") field(INP, "@PLC_LI00_PP01/168 T=WORD") } # One-off PVs record(mbbi, "PPS:LI00:1:SumAccess") { field(SCAN, "Passive") field(DTYP, "Soft Channel") field(INP, "PPS:LI00:1:CalcSumAccess MS") field(ZRST, "Undefined") field(ONST, "No") field(TWST, "Restricted") field(THST, "Controlled") field(FRST, "Permitted") field(ZRSV, "MAJOR") field(ONSV, "NO_ALARM") field(TWSV, "MINOR") field(THSV, "MAJOR") field(FRSV, "MAJOR") } record(calc, "PPS:LI00:1:CalcSumAccess") { field(SCAN, "1 second") field(FLNK, "PPS:LI00:1:SumAccess") field(CALC, "A&&!B&&!C&&!D?1:!A&&B&&!C&&!D?2:!A&&!B&&C&&!D?3:!A&&!B&&!C&&D?4:0") field(INPA, "PPS:LI00:1:NoAccess MS") field(INPB, "PPS:LI00:1:RestAccess MS") field(INPC, "PPS:LI00:1:CtrlAccess MS") field(INPD, "PPS:LI00:1:PermAccess MS") } record(calc, "DOOR:GUNB:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:GUNB:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:GUNB:1:Closed MS") field(INPB, "DOOR:GUNB:1:Locked MS") } record(mbbi, "DOOR:GUNB:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:GUNB:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(calc, "DOOR:LI00:1:CalcClosedLocked") { field(SCAN, ".1 second") field(FLNK, "DOOR:LI00:1:ClosedLocked") field(CALC, "!B?A:A&&B?2:3") field(INPA, "DOOR:LI00:1:Closed MS") field(INPB, "DOOR:LI00:1:Locked MS") } record(mbbi, "DOOR:LI00:1:ClosedLocked") { field(SCAN, "Passive") field(ZRST, "NotClosed") field(ONST, "Closed") field(TWST, "Locked") field(INP, "DOOR:LI00:1:CalcClosedLocked MS") field(ZRSV, "MAJOR") field(ONSV, "MINOR") field(TWSV, "NO_ALARM") field(THST, "INVALID") field(THSV, "INVALID") } record(bo, "BSOC:SYSW:1:SResetAll") { field(DESC, "Reset all West Global BSOICs") field(OUT, "BSOC:SYSW:1:SResetAllFanout PP MS") field(HIGH, 1) } record(dfanout, "BSOC:SYSW:1:SResetAllFanout") { field(DESC, "Reset all West Global BSOICs") field(DOL, "BSOC:SYSW:1:SResetAll") field(OMSL, "closed_loop") field(OUTA, "BSOC:GUNB:1:SResetAll PP") field(OUTB, "BSOC:LI01:1:SResetAll PP") field(OUTC, "BSOC:LI03:1:SResetAll PP") field(OUTD, "BSOC:LI06:1:SResetAll PP") field(OUTE, "BSOC:LI08:1:SResetAll PP") field(ASG, "MCC") } record(stringin, "APC:LI01A:1:2002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01a_2002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01A:1:1002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01a_1002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01A:1:1002_2_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01a_1002_2,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01A:1:1002_3_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01a_1002_3,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06A:1:1002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06a_1002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06A:1:1002_2_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06a_1002_2,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06A:1:1002_3_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06a_1002_3,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(bi, "APC:LI01A:1:2002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_2002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01A:1:2002_1_ERROR_PUSH") } record(waveform, "APC:LI01A:1:2002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01a_2002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI01A:1:2002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_2002_1 0 1)BO_TEST") } record(bo, "APC:LI01A:1:2002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01A:1:2002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:Error PP") } record(bi, "APC:LI01A:1:1002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01A:1:1002_1_ERROR_PUSH") } record(waveform, "APC:LI01A:1:1002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01a_1002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI01A:1:1002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_1002_1 0 1)BO_TEST") } record(bo, "APC:LI01A:1:1002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01A:1:1002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:Error PP") } record(bi, "APC:LI01A:1:1002_2_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01A:1:1002_2_ERROR_PUSH") } record(waveform, "APC:LI01A:1:1002_2_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01a_1002_2,0,1)WF_MESSAGE") } record(bo, "APC:LI01A:1:1002_2_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_1002_2 0 1)BO_TEST") } record(bo, "APC:LI01A:1:1002_2_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01A:1:1002_2_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:Error PP") } record(bi, "APC:LI01A:1:1002_3_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_3 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01A:1:1002_3_ERROR_PUSH") } record(waveform, "APC:LI01A:1:1002_3_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01a_1002_3,0,1)WF_MESSAGE") } record(bo, "APC:LI01A:1:1002_3_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_1002_3 0 1)BO_TEST") } record(bo, "APC:LI01A:1:1002_3_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01A:1:1002_3_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:Error PP") } record(bi, "APC:LI06A:1:1002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06A:1:1002_1_ERROR_PUSH") } record(waveform, "APC:LI06A:1:1002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06a_1002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI06A:1:1002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_1002_1 0 1)BO_TEST") } record(bo, "APC:LI06A:1:1002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06A:1:1002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:Error PP") } record(bi, "APC:LI06A:1:1002_2_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06A:1:1002_2_ERROR_PUSH") } record(waveform, "APC:LI06A:1:1002_2_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06a_1002_2,0,1)WF_MESSAGE") } record(bo, "APC:LI06A:1:1002_2_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_1002_2 0 1)BO_TEST") } record(bo, "APC:LI06A:1:1002_2_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06A:1:1002_2_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:Error PP") } record(bi, "APC:LI06A:1:1002_3_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_3 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06A:1:1002_3_ERROR_PUSH") } record(waveform, "APC:LI06A:1:1002_3_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06a_1002_3,0,1)WF_MESSAGE") } record(bo, "APC:LI06A:1:1002_3_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_1002_3 0 1)BO_TEST") } record(bo, "APC:LI06A:1:1002_3_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06A:1:1002_3_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:Error PP") } #----- Bus coupler records ------------------------------------------- record(stringin, "APC:LI01A:1:Name"){ field(DESC, "") field(VAL, "LI01A") } record(stringin, "APC:LI01A:1:ID"){ field(DESC, "Bus Coupler ID") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01a_BK9kR,0,1) SI_MID") field(SCAN, "I/O Intr") } record(bo, "APC:LI01A:1:WDReset"){ field(DESC, "Watchdog Reset") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_BK9kW,0,1) BO_WDRST") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } record(bo, "APC:LI01A:1:ReadData"){ field(DESC, "Read coupler data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_BK9kR,0,1) BO_REFRESH") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(PINI, "1") field(SCAN, "10 second") field(FLNK, "APC:LI01A:1:ReadID") } record(bo, "APC:LI01A:1:ReadID"){ field(DESC, "Read coupler ID") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_BK9kR,0,1) BO_CINIT") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(FLNK, "APC:LI01A:1:ReadRWData") } record(bo, "APC:LI01A:1:ReadRWData"){ field(DESC, "Read coupler r/w data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_BK9kW,0,1) REFRESH_RW") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } #--- The next 4 records are used to control how many messages #--- are allowed in the low priority message queue (in drvMBus) ---- record(longout, "APC:LI01A:1:NumLPQMax"){ field(DESC, "Low prio queue length") field(OUT, "APC:LI01A:1:NumLPQMax_Write PP") } record(longout, "APC:LI01A:1:NumLPQMax_Write"){ field(SDIS, "APC:LI01A:1:NumLPQMax_Sync.PACT") field(DISV, "1") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01a_DEBUG,0,1) LO_ALLOWINLQ") } record(longin, "APC:LI01A:1:NumLPQMax_RBV"){ field(DESC, "Low prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_DEBUG,0,1) LI_ALLOWINLQ") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:NumLPQMax_Sync") field(PINI, "YES") } record(longout, "APC:LI01A:1:NumLPQMax_Sync"){ field(DOL, "APC:LI01A:1:NumLPQMax_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:NumLPQMax PP") } #------------------------------------- #--- High priority message queue length record(longin, "APC:LI01A:1:NumHPQMax_RBV"){ field(DESC, "Hi prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_DEBUG,0,1) LI_ALLOWINHQ") field(PINI, "YES") } #--- Number of messages in queues record(longin, "APC:LI01A:1:NumLPQ_RBV"){ field(DESC, "Num in low prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_DEBUG,0,1) NUMINLQ") field(SCAN, "5 second") field(PINI, "YES") } record(longin, "APC:LI01A:1:NumHPQ_RBV"){ field(DESC, "Num in hi prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_DEBUG,0,1) NUMINHQ") field(SCAN, "5 second") field(PINI, "YES") } #-- Global error flag ----------------- record(bi, "APC:LI01A:1:Error"){ field(DESC, "Error summary") field(ZNAM, "OK") field(ONAM, "Error") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } #------------------------------------- #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:PLCInt"){ field(DESC, "PLC Interface") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01a_BK9kR,10,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:Diag"){ field(DESC, "Bus Term Diag") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01a_BK9kR,11,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:Status"){ field(DESC, "Bus Coupler Status") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01a_BK9kR,12,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:AOLen"){ field(DESC, "Anlg Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01a_BK9kR,16,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:AILen"){ field(DESC, "Anlg Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01a_BK9kR,17,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:BOLen"){ field(DESC, "Digi Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01a_BK9kR,18,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:BILen"){ field(DESC, "Digi Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01a_BK9kR,19,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01A:1:WDTime"){ field(DESC, "Watchdog Curr. Time") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li01a_BK9kR,32,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01A:1:PLCIntW"){ field(DESC, "PLC Interface") field(EGU, "") field(OUT, "APC:LI01A:1:PLCIntW_Write PP") } record(longout, "APC:LI01A:1:PLCIntW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01A:1:PLCIntW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_BK9kW 0 1)LO_CREG") } record(longin, "APC:LI01A:1:PLCIntW_RBV"){ field(DESC, "PLC Interface RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01a_BK9kW 0 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:PLCIntW_Sync") } record(longout, "APC:LI01A:1:PLCIntW_Sync"){ field(DOL, "APC:LI01A:1:PLCIntW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:PLCIntW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01A:1:DiagW"){ field(DESC, "Bus Term Diag. Inter.") field(EGU, "") field(OUT, "APC:LI01A:1:DiagW_Write PP") } record(longout, "APC:LI01A:1:DiagW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01A:1:DiagW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_BK9kW 1 1)LO_CREG") } record(longin, "APC:LI01A:1:DiagW_RBV"){ field(DESC, "Bus Term Diag. Inter. RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01a_BK9kW 1 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:DiagW_Sync") } record(longout, "APC:LI01A:1:DiagW_Sync"){ field(DOL, "APC:LI01A:1:DiagW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:DiagW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01A:1:WDTout"){ field(DESC, "Watchdog Timeout") field(EGU, "ms") field(OUT, "APC:LI01A:1:WDTout_Write PP") } record(longout, "APC:LI01A:1:WDTout_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01A:1:WDTout_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_BK9kW 22 1)LO_CREG") } record(longin, "APC:LI01A:1:WDTout_RBV"){ field(DESC, "Watchdog Timeout RBV") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li01a_BK9kW 22 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:WDTout_Sync") } record(longout, "APC:LI01A:1:WDTout_Sync"){ field(DOL, "APC:LI01A:1:WDTout_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:WDTout PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01A:1:WDRstReg"){ field(DESC, "Watchdog Reset Reg") field(EGU, "") field(OUT, "APC:LI01A:1:WDRstReg_Write PP") } record(longout, "APC:LI01A:1:WDRstReg_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01A:1:WDRstReg_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_BK9kW 23 1)LO_CREG") } record(longin, "APC:LI01A:1:WDRstReg_RBV"){ field(DESC, "Watchdog Reset Reg RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01a_BK9kW 23 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:WDRstReg_Sync") } record(longout, "APC:LI01A:1:WDRstReg_Sync"){ field(DOL, "APC:LI01A:1:WDRstReg_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:WDRstReg PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI01A:1:WDType"){ field(DESC, "Watchdog Type") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(OUT, "APC:LI01A:1:WDType_Write PP") } record(longout, "APC:LI01A:1:WDType_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01A:1:WDType_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_BK9kW 24 1)LO_CREG") } record(bi, "APC:LI01A:1:WDType_RBV"){ field(DESC, "Watchdog Type RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_BK9kW 24 1)LI_CREG") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:WDType_Sync") } record(longout, "APC:LI01A:1:WDType_Sync"){ field(DOL, "APC:LI01A:1:WDType_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:WDType PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI01A:1:MTCPMode"){ field(DESC, "Modbus TCP Mode") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(OUT, "APC:LI01A:1:MTCPMode_Write PP") } record(longout, "APC:LI01A:1:MTCPMode_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01A:1:MTCPMode_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_BK9kW 25 1)LO_CREG") } record(bi, "APC:LI01A:1:MTCPMode_RBV"){ field(DESC, "Modbus TCP Mode RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_BK9kW 25 1)LI_CREG") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01A:1:MTCPMode_Sync") } record(longout, "APC:LI01A:1:MTCPMode_Sync"){ field(DOL, "APC:LI01A:1:MTCPMode_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01A:1:MTCPMode PP") } #----- Bus coupler records ------------------------------------------- record(stringin, "APC:LI06A:1:Name"){ field(DESC, "") field(VAL, "LI06A") } record(stringin, "APC:LI06A:1:ID"){ field(DESC, "Bus Coupler ID") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06a_BK9kR,0,1) SI_MID") field(SCAN, "I/O Intr") } record(bo, "APC:LI06A:1:WDReset"){ field(DESC, "Watchdog Reset") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_BK9kW,0,1) BO_WDRST") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } record(bo, "APC:LI06A:1:ReadData"){ field(DESC, "Read coupler data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_BK9kR,0,1) BO_REFRESH") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(PINI, "1") field(SCAN, "10 second") field(FLNK, "APC:LI06A:1:ReadID") } record(bo, "APC:LI06A:1:ReadID"){ field(DESC, "Read coupler ID") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_BK9kR,0,1) BO_CINIT") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(FLNK, "APC:LI06A:1:ReadRWData") } record(bo, "APC:LI06A:1:ReadRWData"){ field(DESC, "Read coupler r/w data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_BK9kW,0,1) REFRESH_RW") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } #--- The next 4 records are used to control how many messages #--- are allowed in the low priority message queue (in drvMBus) ---- record(longout, "APC:LI06A:1:NumLPQMax"){ field(DESC, "Low prio queue length") field(OUT, "APC:LI06A:1:NumLPQMax_Write PP") } record(longout, "APC:LI06A:1:NumLPQMax_Write"){ field(SDIS, "APC:LI06A:1:NumLPQMax_Sync.PACT") field(DISV, "1") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06a_DEBUG,0,1) LO_ALLOWINLQ") } record(longin, "APC:LI06A:1:NumLPQMax_RBV"){ field(DESC, "Low prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_DEBUG,0,1) LI_ALLOWINLQ") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:NumLPQMax_Sync") field(PINI, "YES") } record(longout, "APC:LI06A:1:NumLPQMax_Sync"){ field(DOL, "APC:LI06A:1:NumLPQMax_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:NumLPQMax PP") } #------------------------------------- #--- High priority message queue length record(longin, "APC:LI06A:1:NumHPQMax_RBV"){ field(DESC, "Hi prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_DEBUG,0,1) LI_ALLOWINHQ") field(PINI, "YES") } #--- Number of messages in queues record(longin, "APC:LI06A:1:NumLPQ_RBV"){ field(DESC, "Num in low prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_DEBUG,0,1) NUMINLQ") field(SCAN, "5 second") field(PINI, "YES") } record(longin, "APC:LI06A:1:NumHPQ_RBV"){ field(DESC, "Num in hi prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_DEBUG,0,1) NUMINHQ") field(SCAN, "5 second") field(PINI, "YES") } #-- Global error flag ----------------- record(bi, "APC:LI06A:1:Error"){ field(DESC, "Error summary") field(ZNAM, "OK") field(ONAM, "Error") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } #------------------------------------- #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:PLCInt"){ field(DESC, "PLC Interface") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06a_BK9kR,10,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:Diag"){ field(DESC, "Bus Term Diag") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06a_BK9kR,11,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:Status"){ field(DESC, "Bus Coupler Status") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06a_BK9kR,12,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:AOLen"){ field(DESC, "Anlg Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06a_BK9kR,16,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:AILen"){ field(DESC, "Anlg Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06a_BK9kR,17,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:BOLen"){ field(DESC, "Digi Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06a_BK9kR,18,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:BILen"){ field(DESC, "Digi Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06a_BK9kR,19,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06A:1:WDTime"){ field(DESC, "Watchdog Curr. Time") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li06a_BK9kR,32,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06A:1:PLCIntW"){ field(DESC, "PLC Interface") field(EGU, "") field(OUT, "APC:LI06A:1:PLCIntW_Write PP") } record(longout, "APC:LI06A:1:PLCIntW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06A:1:PLCIntW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06a_BK9kW 0 1)LO_CREG") } record(longin, "APC:LI06A:1:PLCIntW_RBV"){ field(DESC, "PLC Interface RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06a_BK9kW 0 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:PLCIntW_Sync") } record(longout, "APC:LI06A:1:PLCIntW_Sync"){ field(DOL, "APC:LI06A:1:PLCIntW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:PLCIntW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06A:1:DiagW"){ field(DESC, "Bus Term Diag. Inter.") field(EGU, "") field(OUT, "APC:LI06A:1:DiagW_Write PP") } record(longout, "APC:LI06A:1:DiagW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06A:1:DiagW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06a_BK9kW 1 1)LO_CREG") } record(longin, "APC:LI06A:1:DiagW_RBV"){ field(DESC, "Bus Term Diag. Inter. RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06a_BK9kW 1 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:DiagW_Sync") } record(longout, "APC:LI06A:1:DiagW_Sync"){ field(DOL, "APC:LI06A:1:DiagW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:DiagW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06A:1:WDTout"){ field(DESC, "Watchdog Timeout") field(EGU, "ms") field(OUT, "APC:LI06A:1:WDTout_Write PP") } record(longout, "APC:LI06A:1:WDTout_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06A:1:WDTout_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06a_BK9kW 22 1)LO_CREG") } record(longin, "APC:LI06A:1:WDTout_RBV"){ field(DESC, "Watchdog Timeout RBV") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li06a_BK9kW 22 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:WDTout_Sync") } record(longout, "APC:LI06A:1:WDTout_Sync"){ field(DOL, "APC:LI06A:1:WDTout_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:WDTout PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06A:1:WDRstReg"){ field(DESC, "Watchdog Reset Reg") field(EGU, "") field(OUT, "APC:LI06A:1:WDRstReg_Write PP") } record(longout, "APC:LI06A:1:WDRstReg_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06A:1:WDRstReg_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06a_BK9kW 23 1)LO_CREG") } record(longin, "APC:LI06A:1:WDRstReg_RBV"){ field(DESC, "Watchdog Reset Reg RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06a_BK9kW 23 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:WDRstReg_Sync") } record(longout, "APC:LI06A:1:WDRstReg_Sync"){ field(DOL, "APC:LI06A:1:WDRstReg_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:WDRstReg PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI06A:1:WDType"){ field(DESC, "Watchdog Type") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(OUT, "APC:LI06A:1:WDType_Write PP") } record(longout, "APC:LI06A:1:WDType_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06A:1:WDType_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06a_BK9kW 24 1)LO_CREG") } record(bi, "APC:LI06A:1:WDType_RBV"){ field(DESC, "Watchdog Type RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_BK9kW 24 1)LI_CREG") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:WDType_Sync") } record(longout, "APC:LI06A:1:WDType_Sync"){ field(DOL, "APC:LI06A:1:WDType_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:WDType PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI06A:1:MTCPMode"){ field(DESC, "Modbus TCP Mode") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(OUT, "APC:LI06A:1:MTCPMode_Write PP") } record(longout, "APC:LI06A:1:MTCPMode_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06A:1:MTCPMode_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06a_BK9kW 25 1)LO_CREG") } record(bi, "APC:LI06A:1:MTCPMode_RBV"){ field(DESC, "Modbus TCP Mode RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_BK9kW 25 1)LI_CREG") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06A:1:MTCPMode_Sync") } record(longout, "APC:LI06A:1:MTCPMode_Sync"){ field(DOL, "APC:LI06A:1:MTCPMode_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06A:1:MTCPMode PP") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI00:1:PPSOffSumyA"){ field(DESC, "LI00 RF AND Buncher SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:ZoneClearA"){ field(DESC, "LI00 Zone Clear") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:ZoneRadReadyA"){ field(DESC, "LI00 Zone Rad Ready") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:ZoneKeybanksA"){ field(DESC, "LI00 Zone Keybanks Complete") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 3 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI00:1:SumyA"){ field(DESC, "LI00 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI00:2:SumyA"){ field(DESC, "LI00 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:GBL0:1:EmerOffA"){ field(DESC, "LAF Emergency Shutoff") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 6 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:GBL0:1:IgnitionKeyA"){ field(DESC, "LAF Ignition Key Switch") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:GUNB:1:PPSOffSumyA"){ field(DESC, "LI00 Gun SSA OFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "KLYS:DIAG0:1:PPSOffSumyA"){ field(DESC, "LI00 RF TCAV OFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYS0:1:BCSFaultA"){ field(DESC, "LCLS-II-BCS TO PPS escalation shut-off") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 10 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI01:1:PPSOffSumyA"){ field(DESC, "LI01 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 11 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI01:1:SumyA"){ field(DESC, "LI01 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI01:2:SumyA"){ field(DESC, "LI01 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 13 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI03:1:PPSOffSumyA"){ field(DESC, "LI03 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 14 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:ZoneClearA"){ field(DESC, "LI01-LI07 Zone Clear") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_1 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:ZoneRadReadyA"){ field(DESC, "LI00-LI07 Zone Rad Ready") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:ZoneKeybanksA"){ field(DESC, "LI01-LI07 Zone Keybanks Complete") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI03:1:FaultStatusA"){ field(DESC, "LI03 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI03:1:SumyA"){ field(DESC, "LI03 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 3 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "ODM:LI03:1:SumyA"){ field(DESC, "S03 ODM Sum Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI06:1:PPSOffSumyA"){ field(DESC, "LI06 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI06:1:SumyA"){ field(DESC, "LI06 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 6 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI06:1:SumyA"){ field(DESC, "LI06 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI08:1:PPSOffSumyA"){ field(DESC, "LI08 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:ZoneClearA"){ field(DESC, "LI08-LI10 Zone Clear") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:ZoneRadReadyA"){ field(DESC, "LI08-LI10 Zone Rad Ready") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 10 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:ZoneKeybanksA"){ field(DESC, "LI08-LI10 Zone Keybanks Complete") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 11 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI08:1:FaultStatusA"){ field(DESC, "LI08 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI08:2:SumyA"){ field(DESC, "LI08 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 13 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSM:1:USRfReadyA"){ field(DESC, "LM Ready for Upstream RF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 14 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSM:1:USRadReadyA"){ field(DESC, "LM Ready for Upstream Beam") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_2 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:AdminEnableA"){ field(DESC, "B_RIO LW Administrative Stopper Enable") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_3 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:1:AliveA"){ field(DESC, "LI01 Heartbeat") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01a_1002_3 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:1:AllZoneClearA"){ field(DESC, "LI00 All Zones Clear Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:1:AllKeybanksA"){ field(DESC, "LI00 All Keybanks Complete Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:ClearToLSSA"){ field(DESC, "PPS Clear to LSS") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI00:2:PPSPermitA"){ field(DESC, "LI00 RF AND Buncher SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:GUNB:2:PPSPermitA"){ field(DESC, "LI00 Gun SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "KLYS:DIAG0:2:PPSPermitA"){ field(DESC, "LI00 RF TCAV Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 6 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI01:1:PPSPermitA"){ field(DESC, "LI01 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:ZoneEntryA"){ field(DESC, "West Global in Zone Entry Enabled") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Entry_Not_Set") field(ONAM, "Entry_Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:BeamReadyA"){ field(DESC, "West Global in Ready for Beam") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:FaultCrashA"){ field(DESC, "West Global in Fault Crash") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 10 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Crash") field(ONAM, "Crash") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:OffA"){ field(DESC, "West Global OFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 11 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:AllZoneClearA"){ field(DESC, "LI01-LI07 All Zones Clear Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:1:AllKeybanksA"){ field(DESC, "LI01-LI07 All Keybanks Complete Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 13 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI03:1:PPSPermitA"){ field(DESC, "LI03 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_1 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI06:1:PPSPermitA"){ field(DESC, "LI06 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:OffSumyA"){ field(DESC, "LW_ALLOFF to S10 Injector") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:2:OffSumyA"){ field(DESC, "LW_ALLOFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:EndOffA"){ field(DESC, "LW_ENDOFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 3 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:AllZoneClearA"){ field(DESC, "LI08-LI10 All Zones Clear Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:1:AllKeybanksA"){ field(DESC, "LI08-LI10 All Keybanks Complete Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI08:1:PPSPermitA"){ field(DESC, "LI08 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI10:1:RadReadyA"){ field(DESC, "S10 Injector Rad Ready For exclusn zne") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:SYSW:1:SumyA"){ field(DESC, "EAST PLUS CM BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:ABRadReadyCheckA"){ field(DESC, "Ready for Beam Global Cross Check IN") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:VacRadReadyA"){ field(DESC, "LI08-LI29 PPS Ok to Vacuum") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 14 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:SYSW:2:SumyA"){ field(DESC, "All BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_2 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:AllZoneHazOffA"){ field(DESC, "LI00 All Zones All Hazards off Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_3 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:AllZoneHazOffA"){ field(DESC, "LI01-LI07 All Zones/Hazards off Sumy") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_3 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:AllZoneHazOffA"){ field(DESC, "LI08-LI10 All Zones/Hazards off Sumy") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_3 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PLC:SYSW:1:TestModeA"){ field(DESC, "Test mode") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_3 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "NORMAL") field(ONAM, "TEST") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PLC:LI06:1:AliveA"){ field(DESC, "LI06 Heartbeat") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06a_1002_3 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital output module. #---------------------------------------------------------- record(bo, "PPS:SYSW:1:SetEntryPermitA"){ field(DESC, "ACR command: Set to ZEE") field(OUT, "PPS:SYSW:1:SetEntryPermitA_write PP") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bo, "PPS:SYSW:1:SetEntryPermitA_write"){ field(DTYP, "asynInt32") field(ASG, "Internal") field(SDIS, "PPS:SYSW:1:SetEntryPermitA_sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_2002_1,0,1) BO_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bi, "PPS:SYSW:1:SetEntryPermitA_rbv"){ field(DESC, "ACR command: Set to ZEE RBV") field(DTYP, "asynInt32") field(ASG, "Internal") field(INP, "@asyn(apc_li01a_2002_1,0,1) BI_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") field(SCAN, "I/O Intr") field(PINI, "1") field(FLNK, "PPS:SYSW:1:SetEntryPermitA_sync") } record(bo, "PPS:SYSW:1:SetEntryPermitA_sync"){ field(ASG, "Internal") field(ZNAM, "Not_Set") field(ONAM, "Set") field(DOL, "PPS:SYSW:1:SetEntryPermitA_rbv NPP") field(OMSL, "closed_loop") field(OUT, "PPS:SYSW:1:SetEntryPermitA PP") } # This template is for a digital output module. #---------------------------------------------------------- record(bo, "PPS:SYSW:1:SetBeamPermitA"){ field(DESC, "ACR command: Set to Ready for Beam") field(OUT, "PPS:SYSW:1:SetBeamPermitA_write PP") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bo, "PPS:SYSW:1:SetBeamPermitA_write"){ field(DTYP, "asynInt32") field(ASG, "Internal") field(SDIS, "PPS:SYSW:1:SetBeamPermitA_sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_2002_1,1,1) BO_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bi, "PPS:SYSW:1:SetBeamPermitA_rbv"){ field(DESC, "ACR command: Set to Ready for Beam RBV") field(DTYP, "asynInt32") field(ASG, "Internal") field(INP, "@asyn(apc_li01a_2002_1,1,1) BI_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") field(SCAN, "I/O Intr") field(PINI, "1") field(FLNK, "PPS:SYSW:1:SetBeamPermitA_sync") } record(bo, "PPS:SYSW:1:SetBeamPermitA_sync"){ field(ASG, "Internal") field(ZNAM, "Not_Set") field(ONAM, "Set") field(DOL, "PPS:SYSW:1:SetBeamPermitA_rbv NPP") field(OMSL, "closed_loop") field(OUT, "PPS:SYSW:1:SetBeamPermitA PP") } # This template is for a digital output module. #---------------------------------------------------------- record(bo, "PPS:SYSW:1:HWEnableA"){ field(DESC, "Hardware Enable") field(OUT, "PPS:SYSW:1:HWEnableA_write PP") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PPS:SYSW:1:HWEnableA_write"){ field(DTYP, "asynInt32") field(ASG, "Internal") field(SDIS, "PPS:SYSW:1:HWEnableA_sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01a_2002_1,2,1) BO_BVAL") field(ZNAM, "Off") field(ONAM, "On") } record(bi, "PPS:SYSW:1:HWEnableA_rbv"){ field(DESC, "Hardware Enable RBV") field(DTYP, "asynInt32") field(ASG, "Internal") field(INP, "@asyn(apc_li01a_2002_1,2,1) BI_BVAL") field(ZNAM, "Off") field(ONAM, "On") field(SCAN, "I/O Intr") field(PINI, "1") field(FLNK, "PPS:SYSW:1:HWEnableA_sync") } record(bo, "PPS:SYSW:1:HWEnableA_sync"){ field(ASG, "Internal") field(ZNAM, "Off") field(ONAM, "On") field(DOL, "PPS:SYSW:1:HWEnableA_rbv NPP") field(OMSL, "closed_loop") field(OUT, "PPS:SYSW:1:HWEnableA PP") } record(stringin, "APC:LI01B:1:2002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_2002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01B:1:1002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_1002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01B:1:1002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_1002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01B:1:1002_2_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_1002_2,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01B:1:1002_2_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_1002_2,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI01B:1:1002_3_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_1002_3,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06B:1:1002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06b_1002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06B:1:1002_1_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06b_1002_1,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06B:1:1002_2_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06b_1002_2,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06B:1:1002_2_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06b_1002_2,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(stringin, "APC:LI06B:1:1002_3_DRV_NAME"){ field(DESC, "Driver name") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06b_1002_3,0,1)SI_NAME") field(SCAN, "I/O Intr") } record(bi, "APC:LI01B:1:2002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_2002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01B:1:2002_1_ERROR_PUSH") } record(waveform, "APC:LI01B:1:2002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01b_2002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI01B:1:2002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_2002_1 0 1)BO_TEST") } record(bo, "APC:LI01B:1:2002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01B:1:2002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:Error PP") } record(bi, "APC:LI01B:1:1002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01B:1:1002_1_ERROR_PUSH") } record(waveform, "APC:LI01B:1:1002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01b_1002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI01B:1:1002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_1002_1 0 1)BO_TEST") } record(bo, "APC:LI01B:1:1002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01B:1:1002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:Error PP") } record(bi, "APC:LI01B:1:1002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01B:1:1002_1_ERROR_PUSH") } record(waveform, "APC:LI01B:1:1002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01b_1002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI01B:1:1002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_1002_1 0 1)BO_TEST") } record(bo, "APC:LI01B:1:1002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01B:1:1002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:Error PP") } record(bi, "APC:LI01B:1:1002_2_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01B:1:1002_2_ERROR_PUSH") } record(waveform, "APC:LI01B:1:1002_2_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01b_1002_2,0,1)WF_MESSAGE") } record(bo, "APC:LI01B:1:1002_2_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_1002_2 0 1)BO_TEST") } record(bo, "APC:LI01B:1:1002_2_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01B:1:1002_2_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:Error PP") } record(bi, "APC:LI01B:1:1002_2_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01B:1:1002_2_ERROR_PUSH") } record(waveform, "APC:LI01B:1:1002_2_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01b_1002_2,0,1)WF_MESSAGE") } record(bo, "APC:LI01B:1:1002_2_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_1002_2 0 1)BO_TEST") } record(bo, "APC:LI01B:1:1002_2_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01B:1:1002_2_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:Error PP") } record(bi, "APC:LI01B:1:1002_3_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_3 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI01B:1:1002_3_ERROR_PUSH") } record(waveform, "APC:LI01B:1:1002_3_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li01b_1002_3,0,1)WF_MESSAGE") } record(bo, "APC:LI01B:1:1002_3_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_1002_3 0 1)BO_TEST") } record(bo, "APC:LI01B:1:1002_3_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI01B:1:1002_3_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:Error PP") } record(bi, "APC:LI06B:1:1002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06B:1:1002_1_ERROR_PUSH") } record(waveform, "APC:LI06B:1:1002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06b_1002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI06B:1:1002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_1002_1 0 1)BO_TEST") } record(bo, "APC:LI06B:1:1002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06B:1:1002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:Error PP") } record(bi, "APC:LI06B:1:1002_1_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06B:1:1002_1_ERROR_PUSH") } record(waveform, "APC:LI06B:1:1002_1_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06b_1002_1,0,1)WF_MESSAGE") } record(bo, "APC:LI06B:1:1002_1_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_1002_1 0 1)BO_TEST") } record(bo, "APC:LI06B:1:1002_1_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06B:1:1002_1_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:Error PP") } record(bi, "APC:LI06B:1:1002_2_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06B:1:1002_2_ERROR_PUSH") } record(waveform, "APC:LI06B:1:1002_2_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06b_1002_2,0,1)WF_MESSAGE") } record(bo, "APC:LI06B:1:1002_2_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_1002_2 0 1)BO_TEST") } record(bo, "APC:LI06B:1:1002_2_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06B:1:1002_2_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:Error PP") } record(bi, "APC:LI06B:1:1002_2_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06B:1:1002_2_ERROR_PUSH") } record(waveform, "APC:LI06B:1:1002_2_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06b_1002_2,0,1)WF_MESSAGE") } record(bo, "APC:LI06B:1:1002_2_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_1002_2 0 1)BO_TEST") } record(bo, "APC:LI06B:1:1002_2_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06B:1:1002_2_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:Error PP") } record(bi, "APC:LI06B:1:1002_3_ERROR"){ field(DESC, "Error flag:") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_3 0 1)BI_ERROR") field(SCAN, "I/O Intr") field(ZNAM, "No_Error") field(ONAM, "Error") field(OSV, "MAJOR") field(FLNK, "APC:LI06B:1:1002_3_ERROR_PUSH") } record(waveform, "APC:LI06B:1:1002_3_MSG"){ field(DESC, "error message") field(SCAN, "I/O Intr") field(DTYP, "asynOctetRead") field(FTVL, "CHAR") field(NELM, "100") field(INP, "@asyn(apc_li06b_1002_3,0,1)WF_MESSAGE") } record(bo, "APC:LI06B:1:1002_3_TEST"){ field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_1002_3 0 1)BO_TEST") } record(bo, "APC:LI06B:1:1002_3_ERROR_PUSH"){ field(DESC, "Push to global error flag") field(ASG, "Internal") field(DOL, "APC:LI06B:1:1002_3_ERROR") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:Error PP") } #----- Bus coupler records ------------------------------------------- record(stringin, "APC:LI01B:1:Name"){ field(DESC, "") field(VAL, "LI01B") } record(stringin, "APC:LI01B:1:ID"){ field(DESC, "Bus Coupler ID") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li01b_BK9kR,0,1) SI_MID") field(SCAN, "I/O Intr") } record(bo, "APC:LI01B:1:WDReset"){ field(DESC, "Watchdog Reset") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_BK9kW,0,1) BO_WDRST") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } record(bo, "APC:LI01B:1:ReadData"){ field(DESC, "Read coupler data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_BK9kR,0,1) BO_REFRESH") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(PINI, "1") field(SCAN, "10 second") field(FLNK, "APC:LI01B:1:ReadID") } record(bo, "APC:LI01B:1:ReadID"){ field(DESC, "Read coupler ID") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_BK9kR,0,1) BO_CINIT") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(FLNK, "APC:LI01B:1:ReadRWData") } record(bo, "APC:LI01B:1:ReadRWData"){ field(DESC, "Read coupler r/w data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_BK9kW,0,1) REFRESH_RW") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } #--- The next 4 records are used to control how many messages #--- are allowed in the low priority message queue (in drvMBus) ---- record(longout, "APC:LI01B:1:NumLPQMax"){ field(DESC, "Low prio queue length") field(OUT, "APC:LI01B:1:NumLPQMax_Write PP") } record(longout, "APC:LI01B:1:NumLPQMax_Write"){ field(SDIS, "APC:LI01B:1:NumLPQMax_Sync.PACT") field(DISV, "1") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li01b_DEBUG,0,1) LO_ALLOWINLQ") } record(longin, "APC:LI01B:1:NumLPQMax_RBV"){ field(DESC, "Low prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_DEBUG,0,1) LI_ALLOWINLQ") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:NumLPQMax_Sync") field(PINI, "YES") } record(longout, "APC:LI01B:1:NumLPQMax_Sync"){ field(DOL, "APC:LI01B:1:NumLPQMax_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:NumLPQMax PP") } #------------------------------------- #--- High priority message queue length record(longin, "APC:LI01B:1:NumHPQMax_RBV"){ field(DESC, "Hi prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_DEBUG,0,1) LI_ALLOWINHQ") field(PINI, "YES") } #--- Number of messages in queues record(longin, "APC:LI01B:1:NumLPQ_RBV"){ field(DESC, "Num in low prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_DEBUG,0,1) NUMINLQ") field(SCAN, "5 second") field(PINI, "YES") } record(longin, "APC:LI01B:1:NumHPQ_RBV"){ field(DESC, "Num in hi prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_DEBUG,0,1) NUMINHQ") field(SCAN, "5 second") field(PINI, "YES") } #-- Global error flag ----------------- record(bi, "APC:LI01B:1:Error"){ field(DESC, "Error summary") field(ZNAM, "OK") field(ONAM, "Error") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } #------------------------------------- #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:PLCInt"){ field(DESC, "PLC Interface") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01b_BK9kR,10,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:Diag"){ field(DESC, "Bus Term Diag") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01b_BK9kR,11,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:Status"){ field(DESC, "Bus Coupler Status") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01b_BK9kR,12,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:AOLen"){ field(DESC, "Anlg Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01b_BK9kR,16,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:AILen"){ field(DESC, "Anlg Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01b_BK9kR,17,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:BOLen"){ field(DESC, "Digi Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01b_BK9kR,18,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:BILen"){ field(DESC, "Digi Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li01b_BK9kR,19,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI01B:1:WDTime"){ field(DESC, "Watchdog Curr. Time") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li01b_BK9kR,32,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01B:1:PLCIntW"){ field(DESC, "PLC Interface") field(EGU, "") field(OUT, "APC:LI01B:1:PLCIntW_Write PP") } record(longout, "APC:LI01B:1:PLCIntW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01B:1:PLCIntW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_BK9kW 0 1)LO_CREG") } record(longin, "APC:LI01B:1:PLCIntW_RBV"){ field(DESC, "PLC Interface RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01b_BK9kW 0 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:PLCIntW_Sync") } record(longout, "APC:LI01B:1:PLCIntW_Sync"){ field(DOL, "APC:LI01B:1:PLCIntW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:PLCIntW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01B:1:DiagW"){ field(DESC, "Bus Term Diag. Inter.") field(EGU, "") field(OUT, "APC:LI01B:1:DiagW_Write PP") } record(longout, "APC:LI01B:1:DiagW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01B:1:DiagW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_BK9kW 1 1)LO_CREG") } record(longin, "APC:LI01B:1:DiagW_RBV"){ field(DESC, "Bus Term Diag. Inter. RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01b_BK9kW 1 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:DiagW_Sync") } record(longout, "APC:LI01B:1:DiagW_Sync"){ field(DOL, "APC:LI01B:1:DiagW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:DiagW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01B:1:WDTout"){ field(DESC, "Watchdog Timeout") field(EGU, "ms") field(OUT, "APC:LI01B:1:WDTout_Write PP") } record(longout, "APC:LI01B:1:WDTout_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01B:1:WDTout_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_BK9kW 22 1)LO_CREG") } record(longin, "APC:LI01B:1:WDTout_RBV"){ field(DESC, "Watchdog Timeout RBV") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li01b_BK9kW 22 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:WDTout_Sync") } record(longout, "APC:LI01B:1:WDTout_Sync"){ field(DOL, "APC:LI01B:1:WDTout_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:WDTout PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI01B:1:WDRstReg"){ field(DESC, "Watchdog Reset Reg") field(EGU, "") field(OUT, "APC:LI01B:1:WDRstReg_Write PP") } record(longout, "APC:LI01B:1:WDRstReg_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01B:1:WDRstReg_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_BK9kW 23 1)LO_CREG") } record(longin, "APC:LI01B:1:WDRstReg_RBV"){ field(DESC, "Watchdog Reset Reg RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li01b_BK9kW 23 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:WDRstReg_Sync") } record(longout, "APC:LI01B:1:WDRstReg_Sync"){ field(DOL, "APC:LI01B:1:WDRstReg_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:WDRstReg PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI01B:1:WDType"){ field(DESC, "Watchdog Type") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(OUT, "APC:LI01B:1:WDType_Write PP") } record(longout, "APC:LI01B:1:WDType_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01B:1:WDType_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_BK9kW 24 1)LO_CREG") } record(bi, "APC:LI01B:1:WDType_RBV"){ field(DESC, "Watchdog Type RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_BK9kW 24 1)LI_CREG") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:WDType_Sync") } record(longout, "APC:LI01B:1:WDType_Sync"){ field(DOL, "APC:LI01B:1:WDType_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:WDType PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI01B:1:MTCPMode"){ field(DESC, "Modbus TCP Mode") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(OUT, "APC:LI01B:1:MTCPMode_Write PP") } record(longout, "APC:LI01B:1:MTCPMode_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI01B:1:MTCPMode_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_BK9kW 25 1)LO_CREG") } record(bi, "APC:LI01B:1:MTCPMode_RBV"){ field(DESC, "Modbus TCP Mode RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_BK9kW 25 1)LI_CREG") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(SCAN, "I/O Intr") field(FLNK, "APC:LI01B:1:MTCPMode_Sync") } record(longout, "APC:LI01B:1:MTCPMode_Sync"){ field(DOL, "APC:LI01B:1:MTCPMode_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI01B:1:MTCPMode PP") } #----- Bus coupler records ------------------------------------------- record(stringin, "APC:LI06B:1:Name"){ field(DESC, "") field(VAL, "LI06B") } record(stringin, "APC:LI06B:1:ID"){ field(DESC, "Bus Coupler ID") field(DTYP, "asynOctetRead") field(INP, "@asyn(apc_li06b_BK9kR,0,1) SI_MID") field(SCAN, "I/O Intr") } record(bo, "APC:LI06B:1:WDReset"){ field(DESC, "Watchdog Reset") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_BK9kW,0,1) BO_WDRST") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } record(bo, "APC:LI06B:1:ReadData"){ field(DESC, "Read coupler data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_BK9kR,0,1) BO_REFRESH") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(PINI, "1") field(SCAN, "10 second") field(FLNK, "APC:LI06B:1:ReadID") } record(bo, "APC:LI06B:1:ReadID"){ field(DESC, "Read coupler ID") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_BK9kR,0,1) BO_CINIT") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") field(FLNK, "APC:LI06B:1:ReadRWData") } record(bo, "APC:LI06B:1:ReadRWData"){ field(DESC, "Read coupler r/w data") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_BK9kW,0,1) REFRESH_RW") field(HIGH, "0.1") field(ZNAM, "off") field(ONAM, "on") field(VAL, "0") } #--- The next 4 records are used to control how many messages #--- are allowed in the low priority message queue (in drvMBus) ---- record(longout, "APC:LI06B:1:NumLPQMax"){ field(DESC, "Low prio queue length") field(OUT, "APC:LI06B:1:NumLPQMax_Write PP") } record(longout, "APC:LI06B:1:NumLPQMax_Write"){ field(SDIS, "APC:LI06B:1:NumLPQMax_Sync.PACT") field(DISV, "1") field(DTYP, "asynInt32") field(OUT, "@asyn(apc_li06b_DEBUG,0,1) LO_ALLOWINLQ") } record(longin, "APC:LI06B:1:NumLPQMax_RBV"){ field(DESC, "Low prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_DEBUG,0,1) LI_ALLOWINLQ") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:NumLPQMax_Sync") field(PINI, "YES") } record(longout, "APC:LI06B:1:NumLPQMax_Sync"){ field(DOL, "APC:LI06B:1:NumLPQMax_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:NumLPQMax PP") } #------------------------------------- #--- High priority message queue length record(longin, "APC:LI06B:1:NumHPQMax_RBV"){ field(DESC, "Hi prio queue length") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_DEBUG,0,1) LI_ALLOWINHQ") field(PINI, "YES") } #--- Number of messages in queues record(longin, "APC:LI06B:1:NumLPQ_RBV"){ field(DESC, "Num in low prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_DEBUG,0,1) NUMINLQ") field(SCAN, "5 second") field(PINI, "YES") } record(longin, "APC:LI06B:1:NumHPQ_RBV"){ field(DESC, "Num in hi prio queue") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_DEBUG,0,1) NUMINHQ") field(SCAN, "5 second") field(PINI, "YES") } #-- Global error flag ----------------- record(bi, "APC:LI06B:1:Error"){ field(DESC, "Error summary") field(ZNAM, "OK") field(ONAM, "Error") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } #------------------------------------- #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:PLCInt"){ field(DESC, "PLC Interface") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06b_BK9kR,10,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:Diag"){ field(DESC, "Bus Term Diag") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06b_BK9kR,11,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:Status"){ field(DESC, "Bus Coupler Status") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06b_BK9kR,12,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:AOLen"){ field(DESC, "Anlg Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06b_BK9kR,16,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:AILen"){ field(DESC, "Anlg Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06b_BK9kR,17,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:BOLen"){ field(DESC, "Digi Output Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06b_BK9kR,18,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:BILen"){ field(DESC, "Digi Input Length") field(DTYP, "asynInt32") field(EGU, "bits") field(INP, "@asyn(apc_li06b_BK9kR,19,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read only register ------------- record(longin, "APC:LI06B:1:WDTime"){ field(DESC, "Watchdog Curr. Time") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li06b_BK9kR,32,1) LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06B:1:PLCIntW"){ field(DESC, "PLC Interface") field(EGU, "") field(OUT, "APC:LI06B:1:PLCIntW_Write PP") } record(longout, "APC:LI06B:1:PLCIntW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06B:1:PLCIntW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06b_BK9kW 0 1)LO_CREG") } record(longin, "APC:LI06B:1:PLCIntW_RBV"){ field(DESC, "PLC Interface RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06b_BK9kW 0 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:PLCIntW_Sync") } record(longout, "APC:LI06B:1:PLCIntW_Sync"){ field(DOL, "APC:LI06B:1:PLCIntW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:PLCIntW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06B:1:DiagW"){ field(DESC, "Bus Term Diag. Inter.") field(EGU, "") field(OUT, "APC:LI06B:1:DiagW_Write PP") } record(longout, "APC:LI06B:1:DiagW_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06B:1:DiagW_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06b_BK9kW 1 1)LO_CREG") } record(longin, "APC:LI06B:1:DiagW_RBV"){ field(DESC, "Bus Term Diag. Inter. RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06b_BK9kW 1 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:DiagW_Sync") } record(longout, "APC:LI06B:1:DiagW_Sync"){ field(DOL, "APC:LI06B:1:DiagW_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:DiagW PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06B:1:WDTout"){ field(DESC, "Watchdog Timeout") field(EGU, "ms") field(OUT, "APC:LI06B:1:WDTout_Write PP") } record(longout, "APC:LI06B:1:WDTout_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06B:1:WDTout_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06b_BK9kW 22 1)LO_CREG") } record(longin, "APC:LI06B:1:WDTout_RBV"){ field(DESC, "Watchdog Timeout RBV") field(DTYP, "asynInt32") field(EGU, "ms") field(INP, "@asyn(apc_li06b_BK9kW 22 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "1") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "MINOR") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:WDTout_Sync") } record(longout, "APC:LI06B:1:WDTout_Sync"){ field(DOL, "APC:LI06B:1:WDTout_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:WDTout PP") } #----- Bus coupler read/write register ------------- record(longout, "APC:LI06B:1:WDRstReg"){ field(DESC, "Watchdog Reset Reg") field(EGU, "") field(OUT, "APC:LI06B:1:WDRstReg_Write PP") } record(longout, "APC:LI06B:1:WDRstReg_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06B:1:WDRstReg_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06b_BK9kW 23 1)LO_CREG") } record(longin, "APC:LI06B:1:WDRstReg_RBV"){ field(DESC, "Watchdog Reset Reg RBV") field(DTYP, "asynInt32") field(EGU, "") field(INP, "@asyn(apc_li06b_BK9kW 23 1)LI_CREG") field(LOLO, "") field(LOW, "") field(HIGH, "") field(HIHI, "") field(LLSV, "NO_ALARM") field(LSV, "NO_ALARM") field(HSV, "NO_ALARM") field(HHSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:WDRstReg_Sync") } record(longout, "APC:LI06B:1:WDRstReg_Sync"){ field(DOL, "APC:LI06B:1:WDRstReg_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:WDRstReg PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI06B:1:WDType"){ field(DESC, "Watchdog Type") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(OUT, "APC:LI06B:1:WDType_Write PP") } record(longout, "APC:LI06B:1:WDType_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06B:1:WDType_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06b_BK9kW 24 1)LO_CREG") } record(bi, "APC:LI06B:1:WDType_RBV"){ field(DESC, "Watchdog Type RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_BK9kW 24 1)LI_CREG") field(ZNAM, "Write tel.") field(ONAM, "Default") field(ZSV, "MINOR") field(OSV, "NO_ALARM") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:WDType_Sync") } record(longout, "APC:LI06B:1:WDType_Sync"){ field(DOL, "APC:LI06B:1:WDType_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:WDType PP") } #----- Bus coupler read/write register ------------- record(bo, "APC:LI06B:1:MTCPMode"){ field(DESC, "Modbus TCP Mode") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(OUT, "APC:LI06B:1:MTCPMode_Write PP") } record(longout, "APC:LI06B:1:MTCPMode_Write"){ field(DTYP, "asynInt32") field(SDIS, "APC:LI06B:1:MTCPMode_Sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li06b_BK9kW 25 1)LO_CREG") } record(bi, "APC:LI06B:1:MTCPMode_RBV"){ field(DESC, "Modbus TCP Mode RBV") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_BK9kW 25 1)LI_CREG") field(ZNAM, "Default") field(ONAM, "Fast") field(ZSV, "NO_ALARM") field(OSV, "MINOR") field(SCAN, "I/O Intr") field(FLNK, "APC:LI06B:1:MTCPMode_Sync") } record(longout, "APC:LI06B:1:MTCPMode_Sync"){ field(DOL, "APC:LI06B:1:MTCPMode_RBV NPP") field(OMSL, "closed_loop") field(OUT, "APC:LI06B:1:MTCPMode PP") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI00:1:PPSOffSumyB"){ field(DESC, "LI00 RF AND Buncher SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:ZoneClearB"){ field(DESC, "LI00 Zone Clear") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:ZoneRadReadyB"){ field(DESC, "LI00 Zone Rad Ready") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:ZoneKeybanksB"){ field(DESC, "LI00 Zone Keybanks Complete") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 3 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI00:1:SumyB"){ field(DESC, "LI00 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI00:2:SumyB"){ field(DESC, "LI00 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:GBL0:1:EmerOffB"){ field(DESC, "LAF Emergency Shutoff") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 6 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:GBL0:1:IgnitionKeyB"){ field(DESC, "LAF Ignition Key Switch") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Enabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:GUNB:1:PPSOffSumyB"){ field(DESC, "LI00 Gun SSA OFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "KLYS:DIAG0:1:PPSOffSumyB"){ field(DESC, "LI00 RF TCAV OFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYS0:1:BCSFaultB"){ field(DESC, "LCLS-II-BCS TO PPS escalation shut-off") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 10 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI01:1:PPSOffSumyB"){ field(DESC, "LI01 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 11 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI01:1:SumyB"){ field(DESC, "LI01 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI01:2:SumyB"){ field(DESC, "LI01 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 13 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI03:1:PPSOffSumyB"){ field(DESC, "LI03 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 14 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:ZoneClearB"){ field(DESC, "LI01-LI07 Zone Clear") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_1 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:ZoneRadReadyB"){ field(DESC, "LI00-LI07 Zone Rad Ready") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:ZoneKeybanksB"){ field(DESC, "LI01-LI07 Zone Keybanks Complete") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI03:1:FaultStatusB"){ field(DESC, "LI03 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI03:1:SumyB"){ field(DESC, "LI03 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 3 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "ODM:LI03:1:SumyB"){ field(DESC, "S03 ODM Sum Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI06:1:PPSOffSumyB"){ field(DESC, "LI06 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI06:1:SumyB"){ field(DESC, "LI06 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 6 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI06:1:SumyB"){ field(DESC, "LI06 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI08:1:PPSOffSumyB"){ field(DESC, "LI08 RF SSA OFF Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:ZoneClearB"){ field(DESC, "LI08-LI10 Zone Clear") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:ZoneRadReadyB"){ field(DESC, "LI08-LI10 Zone Rad Ready") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 10 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:ZoneKeybanksB"){ field(DESC, "LI08-LI10 Zone Keybanks Complete") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 11 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:LI08:1:FaultStatusB"){ field(DESC, "LI08 BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "RADM:LI08:2:SumyB"){ field(DESC, "LI08 RDMs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 13 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSM:1:USRfReadyB"){ field(DESC, "LM Ready for Upstream RF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 14 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSM:1:USRadReadyB"){ field(DESC, "LM Ready for Upstream Beam") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_2 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:AdminEnableB"){ field(DESC, "B_RIO LW Administrative Stopper Enable") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_3 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Disabled") field(ONAM, "Enabled") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:1:AliveB"){ field(DESC, "LI01 Heartbeat") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li01b_1002_3 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:1:AllZoneClearB"){ field(DESC, "LI00 All Zones Clear Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:1:AllKeybanksB"){ field(DESC, "LI00 All Keybanks Complete Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:ClearToLSSB"){ field(DESC, "PPS Clear to LSS") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI00:2:PPSPermitB"){ field(DESC, "LI00 RF AND Buncher SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:GUNB:2:PPSPermitB"){ field(DESC, "LI00 Gun SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "KLYS:DIAG0:2:PPSPermitB"){ field(DESC, "LI00 RF TCAV Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 6 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI01:1:PPSPermitB"){ field(DESC, "LI01 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:ZoneEntryB"){ field(DESC, "West Global in Zone Entry Enabled") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Entry_Not_Set") field(ONAM, "Entry_Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:BeamReadyB"){ field(DESC, "West Global in Ready for Beam") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:FaultCrashB"){ field(DESC, "West Global in Fault Crash") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 10 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Crash") field(ONAM, "Crash") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:OffB"){ field(DESC, "West Global OFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 11 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:AllZoneClearB"){ field(DESC, "LI01-LI07 All Zones Clear Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:1:AllKeybanksB"){ field(DESC, "LI01-LI07 All Keybanks Complete Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 13 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI03:1:PPSPermitB"){ field(DESC, "LI03 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_1 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI06:1:PPSPermitB"){ field(DESC, "LI06 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:OffSumyB"){ field(DESC, "LW_ALLOFF to S10 Injector") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:2:OffSumyB"){ field(DESC, "LW_ALLOFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:EndOffB"){ field(DESC, "LW_ENDOFF") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 3 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:AllZoneClearB"){ field(DESC, "LI08-LI10 All Zones Clear Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 4 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Clear") field(ONAM, "Clear") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:1:AllKeybanksB"){ field(DESC, "LI08-LI10 All Keybanks Complete Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 5 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Complete") field(ONAM, "Complete") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "SSA:LI08:1:PPSPermitB"){ field(DESC, "LI08 RF SSA Permit") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "No_Permit") field(ONAM, "Permit") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI10:1:RadReadyB"){ field(DESC, "S10 Injector Rad Ready For exclusn zne") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 8 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:SYSW:1:SumyB"){ field(DESC, "EAST PLUS CM BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 9 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:ABRadReadyCheckB"){ field(DESC, "Ready for Beam Global Cross Check IN") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 12 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Ready") field(ONAM, "Ready") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:SYSW:1:VacRadReadyB"){ field(DESC, "LI08-LI29 PPS Ok to Vacuum") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 14 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "BSOC:SYSW:2:SumyB"){ field(DESC, "All BSOICs Ok") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_2 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "FAULT") field(ONAM, "Ok") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI00:2:AllZoneHazOffB"){ field(DESC, "LI00 All Zones All Hazards off Summary") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_3 0 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI01:2:AllZoneHazOffB"){ field(DESC, "LI01-LI07 All Zones/Hazards off Sumy") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_3 1 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PPS:LI08:2:AllZoneHazOffB"){ field(DESC, "LI08-LI10 All Zones/Hazards off Sumy") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_3 2 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Not_Off") field(ONAM, "Off") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PLC:SYSW:1:TestModeB"){ field(DESC, "Test mode") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_3 7 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "NORMAL") field(ONAM, "TEST") field(ZSV, "NO_ALARM") field(OSV, "MAJOR") } # This template is for a digital input module. #---------------------------------------------------------- record(bi, "PLC:LI06:1:AliveB"){ field(DESC, "LI06 Heartbeat") field(DTYP, "asynInt32") field(INP, "@asyn(apc_li06b_1002_3 15 1)BI_BVAL") field(SCAN, "I/O Intr") field(ZNAM, "Off") field(ONAM, "On") field(ZSV, "MAJOR") field(OSV, "NO_ALARM") } # This template is for a digital output module. #---------------------------------------------------------- record(bo, "PPS:SYSW:1:SetEntryPermitB"){ field(DESC, "ACR command: Set to ZEE") field(OUT, "PPS:SYSW:1:SetEntryPermitB_write PP") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bo, "PPS:SYSW:1:SetEntryPermitB_write"){ field(DTYP, "asynInt32") field(ASG, "Internal") field(SDIS, "PPS:SYSW:1:SetEntryPermitB_sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_2002_1,0,1) BO_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bi, "PPS:SYSW:1:SetEntryPermitB_rbv"){ field(DESC, "ACR command: Set to ZEE RBV") field(DTYP, "asynInt32") field(ASG, "Internal") field(INP, "@asyn(apc_li01b_2002_1,0,1) BI_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") field(SCAN, "I/O Intr") field(PINI, "1") field(FLNK, "PPS:SYSW:1:SetEntryPermitB_sync") } record(bo, "PPS:SYSW:1:SetEntryPermitB_sync"){ field(ASG, "Internal") field(ZNAM, "Not_Set") field(ONAM, "Set") field(DOL, "PPS:SYSW:1:SetEntryPermitB_rbv NPP") field(OMSL, "closed_loop") field(OUT, "PPS:SYSW:1:SetEntryPermitB PP") } # This template is for a digital output module. #---------------------------------------------------------- record(bo, "PPS:SYSW:1:SetBeamPermitB"){ field(DESC, "ACR command: Set to Ready for Beam") field(OUT, "PPS:SYSW:1:SetBeamPermitB_write PP") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bo, "PPS:SYSW:1:SetBeamPermitB_write"){ field(DTYP, "asynInt32") field(ASG, "Internal") field(SDIS, "PPS:SYSW:1:SetBeamPermitB_sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_2002_1,1,1) BO_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") } record(bi, "PPS:SYSW:1:SetBeamPermitB_rbv"){ field(DESC, "ACR command: Set to Ready for Beam RBV") field(DTYP, "asynInt32") field(ASG, "Internal") field(INP, "@asyn(apc_li01b_2002_1,1,1) BI_BVAL") field(ZNAM, "Not_Set") field(ONAM, "Set") field(SCAN, "I/O Intr") field(PINI, "1") field(FLNK, "PPS:SYSW:1:SetBeamPermitB_sync") } record(bo, "PPS:SYSW:1:SetBeamPermitB_sync"){ field(ASG, "Internal") field(ZNAM, "Not_Set") field(ONAM, "Set") field(DOL, "PPS:SYSW:1:SetBeamPermitB_rbv NPP") field(OMSL, "closed_loop") field(OUT, "PPS:SYSW:1:SetBeamPermitB PP") } # This template is for a digital output module. #---------------------------------------------------------- record(bo, "PPS:SYSW:1:HWEnableB"){ field(DESC, "Hardware Enable") field(OUT, "PPS:SYSW:1:HWEnableB_write PP") field(ZNAM, "Off") field(ONAM, "On") } record(bo, "PPS:SYSW:1:HWEnableB_write"){ field(DTYP, "asynInt32") field(ASG, "Internal") field(SDIS, "PPS:SYSW:1:HWEnableB_sync.PACT") field(DISV, "1") field(OUT, "@asyn(apc_li01b_2002_1,2,1) BO_BVAL") field(ZNAM, "Off") field(ONAM, "On") } record(bi, "PPS:SYSW:1:HWEnableB_rbv"){ field(DESC, "Hardware Enable RBV") field(DTYP, "asynInt32") field(ASG, "Internal") field(INP, "@asyn(apc_li01b_2002_1,2,1) BI_BVAL") field(ZNAM, "Off") field(ONAM, "On") field(SCAN, "I/O Intr") field(PINI, "1") field(FLNK, "PPS:SYSW:1:HWEnableB_sync") } record(bo, "PPS:SYSW:1:HWEnableB_sync"){ field(ASG, "Internal") field(ZNAM, "Off") field(ONAM, "On") field(DOL, "PPS:SYSW:1:HWEnableB_rbv NPP") field(OMSL, "closed_loop") field(OUT, "PPS:SYSW:1:HWEnableB PP") } record(bo, "PPS:SYSW:1:SetEntryPermit") { field(DESC, "West Global Set Entry Permit") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:SYSW:1:SetEntryPermit_DFO") field(ASG, "MCC") } record(dfanout, "PPS:SYSW:1:SetEntryPermit_DFO") { field(DESC, "West Global Set Entry Permit dfanout") field(DOL, "PPS:SYSW:1:SetEntryPermit") field(OMSL, "closed_loop") field(OUTA, "PPS:SYSW:1:SetEntryPermitA PP") field(OUTB, "PPS:SYSW:1:SetEntryPermitB PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:SYSW:1:SetBeamPermit") { field(DESC, "West Global Set Beam Permit") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:SYSW:1:SetBeamPermit_DFO") field(ASG, "MCC") } record(dfanout, "PPS:SYSW:1:SetBeamPermit_DFO") { field(DESC, "West Global Set Beam Permit dfanout") field(DOL, "PPS:SYSW:1:SetBeamPermit") field(OMSL, "closed_loop") field(OUTA, "PPS:SYSW:1:SetBeamPermitA PP") field(OUTB, "PPS:SYSW:1:SetBeamPermitB PP") field(OUTC, " PP") field(ASG, "MCC") } record(bo, "PPS:SYSW:1:HWEnable") { field(DESC, "West Global Hardware Enable") field(ZNAM, "Not_Set") field(ONAM, "Set") field(ZSV, "NO_ALARM") field(OSV, "NO_ALARM") field(FLNK, "PPS:SYSW:1:HWEnable_DFO") field(ASG, "MCC") } record(dfanout, "PPS:SYSW:1:HWEnable_DFO") { field(DESC, "West Global Hardware Enable dfanout") field(DOL, "PPS:SYSW:1:HWEnable") field(OMSL, "closed_loop") field(OUTA, "PPS:SYSW:1:HWEnableA PP") field(OUTB, "PPS:SYSW:1:HWEnableB PP") field(OUTC, " PP") field(ASG, "MCC") }