******************************************* **************** Logic Add **************** ******************************************* Device 'BEND_DMPH_400_INTOL_BRANGE_STATE' added to the logic database. Device 'BEND_UNDH_2810_INTOL_BMIN_STATE' added to the logic database. Device 'XTAL_UNDH_2850_IN_ENCDR_STATE' added to the logic database. Device 'XTAL_UNDH_2850_POSITIONSTAT_STATE' added to the logic database. Device 'XTAL_UNDH_2850_OUT_LMTSW_STATE' added to the logic database. ====================================== Adding HXRSS Chicane Bend Power Supply Added truth table "HXRSS Chicane Bend Power Supply" (2045) Ignored when YAG01 Is In Ignored when YAG02 Is In Ignored when TD11 Is In Ignored when Stopper: BSY D2 Summary Is In Ignored when TDUND Is In Input 0: BEND_UNDH_2810_ON_STATE Input 1: BEND_UNDH_2810_OFF_STATE Adding state "Broken" Gun Linac: None Mechanical Shutter: None BYKIK: 0 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "ON" Gun Linac: None Mechanical Shutter: None BYKIK: 120 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "OFF" Gun Linac: None Mechanical Shutter: None BYKIK: 120 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "Broken" Gun Linac: None Mechanical Shutter: None BYKIK: 0 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding HXRSS Crystal Position Added truth table "HXRSS Crystal Position" (2046) Ignored when YAG01 Is In Ignored when YAG02 Is In Ignored when TD11 Is In Ignored when Stopper: BSY D2 Summary Is In Ignored when TDUND Is In Input 0: XTAL_UNDH_2850_OUT_LMTSW_STATE Input 1: XTAL_UNDH_2850_IN_ENCDR_STATE Adding state "Moving" Gun Linac: None Mechanical Shutter: None BYKIK: 0 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "Out" Gun Linac: None Mechanical Shutter: None BYKIK: 120 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "In" Gun Linac: None Mechanical Shutter: None BYKIK: 120 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "Broken" Gun Linac: None Mechanical Shutter: None BYKIK: 0 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding HXRSS Crystal Valid Position Added truth table "HXRSS Crystal Valid Position" (2047) Ignored when YAG01 Is In Ignored when YAG02 Is In Ignored when TD11 Is In Ignored when Stopper: BSY D2 Summary Is In Ignored when TDUND Is In Input 0: XTAL_UNDH_2850_POSITIONSTAT_STATE Adding state "Not Valid" Gun Linac: None Mechanical Shutter: None BYKIK: 0 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None Adding state "Valid" Gun Linac: None Mechanical Shutter: None BYKIK: 120 Laser Heater Shutter: None Gun HXR: None Gun SXR: None BYKIKS: None ====================================== ******************************************** **************** Device Add **************** ******************************************** The following devices will be added: 11 4 15 BEND DMPH 400 INTOL_BRANGE STATE IS_FAULTED IS_OK 1 BYD INTOL HXRSS 11 5 7 BEND UNDH 2810 INTOL_BMIN STATE IS_FAULTED IS_OK 1 HXRSS Chicane OK 11 6 9 XTAL UNDH 2850 IN_ENCDR STATE IN_NOT_IN IS_IN 1 HXRSS Crystal IN switch 11 4 14 XTAL UNDH 2850 POSITIONSTAT STATE IS_FAULTED IS_OK 1 HXRSS Crystal Encoder State 139 4 6 XTAL UNDH 2850 OUT_LMTSW STATE IS_NOT_OUT IS_OUT 1 HXRSS crystal OUT switch not lp is lp fault is false Adding new Link Node Channel 11.4.15 to database Check if already in ZFAULT: ZDEVICE=BEND_DMPH_400_INTOL_BRANGE and ZNAME=STATE Not found, so adding PV Fault"BEND_DMPH_400_INTOL_BRANGE" STATE Added Channel 11 4 15 -- BEND_DMPH_400_INTOL_BRANGE STATE not lp is lp fault is false Adding new Link Node Channel 11.5.7 to database Check if already in ZFAULT: ZDEVICE=BEND_UNDH_2810_INTOL_BMIN and ZNAME=STATE Not found, so adding PV Fault"BEND_UNDH_2810_INTOL_BMIN" STATE Added Channel 11 5 7 -- BEND_UNDH_2810_INTOL_BMIN STATE not lp is lp fault is false Adding new Link Node Channel 11.6.9 to database Check if already in ZFAULT: ZDEVICE=XTAL_UNDH_2850_IN_ENCDR and ZNAME=STATE Not found, so adding PV Fault"XTAL_UNDH_2850_IN_ENCDR" STATE Added Channel 11 6 9 -- XTAL_UNDH_2850_IN_ENCDR STATE not lp is lp fault is false Adding new Link Node Channel 11.4.14 to database Check if already in ZFAULT: ZDEVICE=XTAL_UNDH_2850_POSITIONSTAT and ZNAME=STATE Not found, so adding PV Fault"XTAL_UNDH_2850_POSITIONSTAT" STATE Added Channel 11 4 14 -- XTAL_UNDH_2850_POSITIONSTAT STATE not lp is lp fault is false Adding new Link Node Channel 139.4.6 to database Check if already in ZFAULT: ZDEVICE=XTAL_UNDH_2850_OUT_LMTSW and ZNAME=STATE Not found, so adding PV Fault"XTAL_UNDH_2850_OUT_LMTSW" STATE Added Channel 139 4 6 -- XTAL_UNDH_2850_OUT_LMTSW STATE ====================================== *********************************************** **************** Device Rename **************** *********************************************** Changes report ------------------ Renamed devices and their affected logic: VVMG_UNDH_2843_POSITION:VVMG_UNDH_2844_POSITION VVMG UNDH 2843 POSITION (inactive) ====================================== ***************************************************** **************** Device/Logic Delete **************** ***************************************************** [INFO] Macro with id:'652' associated with logic device 'BEND_DMP1_400_INTOL_BRANGE_STATE' does not exist. [INFO] Macro with id:'652' associated with logic device 'BEND_UND1_1640_INTOL_BMIN_STATE' does not exist. [INFO] Macro with id:'650' associated with logic device 'XTAL_UND1_1650_IN_ENCDR_STATE' does not exist. [INFO] Macro with id:'652' associated with logic device 'XTAL_UND1_1650_IN_ENCDR_STATE' does not exist. Changes report ------------------ Deleted devices and their deleted associated logic: BEND_UND1_1640_INTOL_BMIN XTAL_UND1_1650_POSITIONSTAT HXRSS Crystal Valid Position (inactive) BEND_DMP1_400_INTOL_BRANGE XTAL_UND1_1650_IN_ENCDR ======================================