record(eg, "EVG:IN20:EV01:CTRL") { field(DESC, "EVG Control") field(DTYP, "MRF Event Generator") field(OUT, "#C0 S0 @") field(PINI, "YES") field(ENAB, "YES") # Clock speed if using internal clock field(R1SP, "118999921") field(R2SP, "118999921") # Clock prescaler (0 = external clock) field(R1CK, "1") field(R2CK, "1") # Max # ticks for any RAM entry (1/360 sec - ~500usec) at 119MHz field(RMAX, "271000") # Start with Sequence RAMs off so they can be set up during initialization field(MOD1, "Off") field(MOD2, "Off") # Only one EVG exists field(FIFO, "NO") # Use the AC input divider for sequence trigger enable field(ASQ1, "YES") field(ASQ2, "YES") # Don't trigger event output 0 from AC input divider. field(AEV0, "NO") # Don't synchronize AC input trigger with multiplexed counter, don't divide it, and don't delay it. field(ASYN, "NO") # ADIV of 0 means bypass phase and divide logic. field(ADIV, "0") field(APHS, "0") # Externally trigger events - set to 100. field(ET0, "100") field(ET1, "100") field(ET2, "100") field(ET3, "100") field(ET4, "100") field(ET5, "100") field(ET6, "100") field(ET7, "100") # There is no multiplexed counter, all MC*,MD*,ME*,MS* fields left at 0. } record(longout, "EVG:IN20:EV01:EVENT") { field(DESC, "EVG User Event Code") field(PINI, "YES") field(DRVH, "256") field(DRVL, "0") field(MDEL, "-1") } record(seq, "EVG:IN20:EV01:EVENTSEND") { field(DESC, "EVG Send User Event Code") field(DOL1, "EVG:IN20:EV01:EVENT") field(LNK1, "EVG:IN20:EV01:CTRL.VME PP") } record(bo, "EVG:IN20:EV01:SEQ1SEND") { field(DESC, "EVG Send Seq 1") field(ZNAM, "No Trigger") field(ONAM, "Trigger") field(DOL, "1") field(OMSL, "closed_loop") field(OUT, "EVG:IN20:EV01:CTRL.TRG1 PP") } record(bo, "EVG:IN20:EV01:SEQ2SEND") { field(DESC, "EVG Send Seq 2") field(ZNAM, "No Trigger") field(ONAM, "Trigger") field(DOL, "1") field(OMSL, "closed_loop") field(OUT, "EVG:IN20:EV01:CTRL.TRG2 PP") }