#! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/0 record(motor, "WIRE:LI18:944:MOTR") { field(DESC, "WS18944 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 0)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI18:944:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI18:944:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI18:944 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI18:944:POSN") { field(DESC, "WS18944 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 0)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI18:944:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI18:944 (WS18944) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI18:944:MASK") { field(DESC, "WS18944 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI18:944:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI18:944 (WS18944) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI18:944:NEWOFFS") { field(DESC, "New WS18944 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI18:944:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI18:944:POSN.EOFF") } record(ao, "WIRE:LI18:944:MOTRVAL") { field(DESC, "WS18944 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI18:944:MOTR.VAL") field(FLNK, "WIRE:LI18:944:MOTR") } record(ao, "WIRE:LI18:944:MOTRHI") { field(DESC, "Move WS18944 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI18:944:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI18:944:MOTR.VAL") field(FLNK, "WIRE:LI18:944:MOTR") } record(ao, "WIRE:LI18:944:MOTRLO") { field(DESC, "Move WS18944 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI18:944:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI18:944:MOTR.VAL") field(FLNK, "WIRE:LI18:944:MOTR") } record(ao, "WIRE:LI18:944:RETRACT") { field(DESC, "WS18944 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI18:944:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI18:944:MOTR.VAL") field(FLNK, "WIRE:LI18:944:MOTR") } record(ai, "WIRE:LI18:944:RETRACT_POSN") { field(DESC, "WS18944 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI18:944:MOTRVELCHOICE") { field(DESC, "WS18944 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI18:944:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI18:944:SYNCMOTPROFILE") { field(DESC, "WS18944 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI18:944:MOTPROFILE") field(LNK2, "WIRE:LI18:944:LVDTPROFILE") field(LNK3, "WIRE:LI18:944:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI18:944:CALIBSYNC") { field(DESC, "WS18944 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI18:944:MOTPROFILE") { field(DESC, "WS18944 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI18:944:POSN PP") } record(compress, "WIRE:LI18:944:LVDTPROFILE") { field(DESC, "WS18944 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI18:944:LVRAW PP") } record(subArray, "WIRE:LI18:944:SUBLPROF") { field(DESC, "WS18944 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI18:944:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI18:944:SUBMPROF") { field(DESC, "WS18944 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI18:944:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI18:944:PMOTPROFILE") { field(DESC, "WS18944 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI18:944:MOTPROFILE") field(FLNK, "WIRE:LI18:944:SUBMPROF") } record(waveform, "WIRE:LI18:944:PLVDTPROFILE") { field(DESC, "WS18944 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI18:944:LVDTPROFILE") field(FLNK, "WIRE:LI18:944:SUBLPROF") } record(ai, "WIRE:LI18:944:MOTRVALREST") { field(INP, "WIRE:LI18:944:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI18:944:MOTR",160,62,0,0,"WIRE:LI18:944:MOTR") #! Field("WIRE:LI18:944:MOTR.FLNK",16777215,1,"WIRE:LI18:944:MOTR.FLNK") #! Field("WIRE:LI18:944:MOTR.RDBL",16777215,1,"WIRE:LI18:944:MOTR.RDBL") #! Field("WIRE:LI18:944:MOTR.OFF",16777215,1,"WIRE:LI18:944:MOTR.OFF") #! Field("WIRE:LI18:944:MOTR.HLM",16777215,1,"WIRE:LI18:944:MOTR.HLM") #! Field("WIRE:LI18:944:MOTR.LLM",16777215,1,"WIRE:LI18:944:MOTR.LLM") #! Field("WIRE:LI18:944:MOTR.VELO",16777215,1,"WIRE:LI18:944:MOTR.VELO") #! Field("WIRE:LI18:944:MOTR.VAL",16777215,1,"WIRE:LI18:944:MOTR.VAL") #! Record("WIRE:LI18:944:POSN",1000,544,0,0,"WIRE:LI18:944:POSN") #! Field("WIRE:LI18:944:POSN.FLNK",16777215,1,"WIRE:LI18:944:POSN.FLNK") #! Field("WIRE:LI18:944:POSN.EOFF",16777215,0,"WIRE:LI18:944:POSN.EOFF") #! Field("WIRE:LI18:944:POSN.VAL",16777215,1,"WIRE:LI18:944:POSN.VAL") #! Record("WIRE:LI18:944:MASK",1340,1352,0,0,"WIRE:LI18:944:MASK") #! Field("WIRE:LI18:944:MASK.FLNK",16777215,1,"WIRE:LI18:944:MASK.FLNK") #! Record("WIRE:LI18:944:NEWOFFS",720,612,0,0,"WIRE:LI18:944:NEWOFFS") #! Field("WIRE:LI18:944:NEWOFFS.DOL",16777215,0,"WIRE:LI18:944:NEWOFFS.DOL") #! Link("WIRE:LI18:944:NEWOFFS.DOL","WIRE:LI18:944:MOTR.OFF") #! Field("WIRE:LI18:944:NEWOFFS.OUT",16777215,1,"WIRE:LI18:944:NEWOFFS.OUT") #! Link("WIRE:LI18:944:NEWOFFS.OUT","WIRE:LI18:944:POSN.EOFF") #! Record("WIRE:LI18:944:MOTRVAL",860,986,0,0,"WIRE:LI18:944:MOTRVAL") #! Field("WIRE:LI18:944:MOTRVAL.OUT",16777215,0,"WIRE:LI18:944:MOTRVAL.OUT") #! Link("WIRE:LI18:944:MOTRVAL.OUT","WIRE:LI18:944:MOTR.VAL") #! Field("WIRE:LI18:944:MOTRVAL.FLNK",16777215,0,"WIRE:LI18:944:MOTRVAL.FLNK") #! Link("WIRE:LI18:944:MOTRVAL.FLNK","WIRE:LI18:944:MOTR") #! Record("WIRE:LI18:944:MOTRHI",860,1238,0,0,"WIRE:LI18:944:MOTRHI") #! Field("WIRE:LI18:944:MOTRHI.DOL",16777215,0,"WIRE:LI18:944:MOTRHI.DOL") #! Link("WIRE:LI18:944:MOTRHI.DOL","WIRE:LI18:944:MOTR.HLM") #! Field("WIRE:LI18:944:MOTRHI.OUT",16777215,0,"WIRE:LI18:944:MOTRHI.OUT") #! Link("WIRE:LI18:944:MOTRHI.OUT","WIRE:LI18:944:MOTR.VAL") #! Field("WIRE:LI18:944:MOTRHI.FLNK",16777215,0,"WIRE:LI18:944:MOTRHI.FLNK") #! Link("WIRE:LI18:944:MOTRHI.FLNK","WIRE:LI18:944:MOTR") #! Record("WIRE:LI18:944:MOTRLO",860,1558,0,0,"WIRE:LI18:944:MOTRLO") #! Field("WIRE:LI18:944:MOTRLO.DOL",16777215,0,"WIRE:LI18:944:MOTRLO.DOL") #! Link("WIRE:LI18:944:MOTRLO.DOL","WIRE:LI18:944:MOTR.LLM") #! Field("WIRE:LI18:944:MOTRLO.OUT",16777215,0,"WIRE:LI18:944:MOTRLO.OUT") #! Link("WIRE:LI18:944:MOTRLO.OUT","WIRE:LI18:944:MOTR.VAL") #! Field("WIRE:LI18:944:MOTRLO.FLNK",16777215,0,"WIRE:LI18:944:MOTRLO.FLNK") #! Link("WIRE:LI18:944:MOTRLO.FLNK","WIRE:LI18:944:MOTR") #! Record("WIRE:LI18:944:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI18:944:MOTRVELCHOICE") #! Field("WIRE:LI18:944:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI18:944:MOTRVELCHOICE.OUT") #! Link("WIRE:LI18:944:MOTRVELCHOICE.OUT","WIRE:LI18:944:MOTR.VELO") #! Record("WIRE:LI18:944:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI18:944:SYNCMOTPROFILE") #! Field("WIRE:LI18:944:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI18:944:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI18:944:SYNCMOTPROFILE.LNK1","WIRE:LI18:944:MOTPROFILE") #! Field("WIRE:LI18:944:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI18:944:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI18:944:SYNCMOTPROFILE.LNK2","WIRE:LI18:944:LVDTPROFILE") #! Field("WIRE:LI18:944:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI18:944:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI18:944:SYNCMOTPROFILE.LNK3","WIRE:LI18:944:CALIBSYNC") #! Record("WIRE:LI18:944:CALIBSYNC",1980,860,0,0,"WIRE:LI18:944:CALIBSYNC") #! Record("WIRE:LI18:944:MOTPROFILE",1380,706,0,1,"WIRE:LI18:944:MOTPROFILE") #! Field("WIRE:LI18:944:MOTPROFILE.INP",16777215,0,"WIRE:LI18:944:MOTPROFILE.INP") #! Link("WIRE:LI18:944:MOTPROFILE.INP","WIRE:LI18:944:POSN.VAL") #! Field("WIRE:LI18:944:MOTPROFILE.VAL",16777215,0,"WIRE:LI18:944:MOTPROFILE.VAL") #! Record("WIRE:LI18:944:LVDTPROFILE",2000,566,0,0,"WIRE:LI18:944:LVDTPROFILE") #! Field("WIRE:LI18:944:LVDTPROFILE.INP",16777215,1,"WIRE:LI18:944:LVDTPROFILE.INP") #! Field("WIRE:LI18:944:LVDTPROFILE.VAL",16777215,1,"WIRE:LI18:944:LVDTPROFILE.VAL") #! Record("WIRE:LI18:944:SUBLPROF",2560,698,0,0,"WIRE:LI18:944:SUBLPROF") #! Field("WIRE:LI18:944:SUBLPROF.INP",16777215,0,"WIRE:LI18:944:SUBLPROF.INP") #! Link("WIRE:LI18:944:SUBLPROF.INP","WIRE:LI18:944:PLVDTPROFILE.VAL") #! Record("WIRE:LI18:944:SUBMPROF",1700,1078,0,0,"WIRE:LI18:944:SUBMPROF") #! Field("WIRE:LI18:944:SUBMPROF.INP",16777215,0,"WIRE:LI18:944:SUBMPROF.INP") #! Link("WIRE:LI18:944:SUBMPROF.INP","WIRE:LI18:944:PMOTPROFILE.VAL") #! Record("WIRE:LI18:944:PMOTPROFILE",1380,998,0,0,"WIRE:LI18:944:PMOTPROFILE") #! Field("WIRE:LI18:944:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI18:944:PMOTPROFILE.FLNK") #! Link("WIRE:LI18:944:PMOTPROFILE.FLNK","WIRE:LI18:944:SUBMPROF") #! Field("WIRE:LI18:944:PMOTPROFILE.VAL",16777215,1,"WIRE:LI18:944:PMOTPROFILE.VAL") #! Field("WIRE:LI18:944:PMOTPROFILE.INP",16777215,0,"WIRE:LI18:944:PMOTPROFILE.INP") #! Link("WIRE:LI18:944:PMOTPROFILE.INP","WIRE:LI18:944:MOTPROFILE.VAL") #! Record("WIRE:LI18:944:PLVDTPROFILE",2280,578,0,0,"WIRE:LI18:944:PLVDTPROFILE") #! Field("WIRE:LI18:944:PLVDTPROFILE.INP",16777215,0,"WIRE:LI18:944:PLVDTPROFILE.INP") #! Link("WIRE:LI18:944:PLVDTPROFILE.INP","WIRE:LI18:944:LVDTPROFILE.VAL") #! Field("WIRE:LI18:944:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI18:944:PLVDTPROFILE.FLNK") #! Link("WIRE:LI18:944:PLVDTPROFILE.FLNK","WIRE:LI18:944:SUBLPROF") #! Field("WIRE:LI18:944:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI18:944:PLVDTPROFILE.VAL") #! Record("WIRE:LI18:944:MOTRVALREST",500,914,0,0,"WIRE:LI18:944:MOTRVALREST") #! Field("WIRE:LI18:944:MOTRVALREST.INP",16777215,0,"WIRE:LI18:944:MOTRVALREST.INP") #! Link("WIRE:LI18:944:MOTRVALREST.INP","WIRE:LI18:944:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/1 record(motor, "WIRE:LI19:144:MOTR") { field(DESC, "WS19144 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 1)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI19:144:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI19:144:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI19:144 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI19:144:POSN") { field(DESC, "WS19144 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 1)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI19:144:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI19:144 (WS19144) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI19:144:MASK") { field(DESC, "WS19144 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI19:144:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI19:144 (WS19144) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI19:144:NEWOFFS") { field(DESC, "New WS19144 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:144:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:144:POSN.EOFF") } record(ao, "WIRE:LI19:144:MOTRVAL") { field(DESC, "WS19144 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI19:144:MOTR.VAL") field(FLNK, "WIRE:LI19:144:MOTR") } record(ao, "WIRE:LI19:144:MOTRHI") { field(DESC, "Move WS19144 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:144:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:144:MOTR.VAL") field(FLNK, "WIRE:LI19:144:MOTR") } record(ao, "WIRE:LI19:144:MOTRLO") { field(DESC, "Move WS19144 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:144:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:144:MOTR.VAL") field(FLNK, "WIRE:LI19:144:MOTR") } record(ao, "WIRE:LI19:144:RETRACT") { field(DESC, "WS19144 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI19:144:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI19:144:MOTR.VAL") field(FLNK, "WIRE:LI19:144:MOTR") } record(ai, "WIRE:LI19:144:RETRACT_POSN") { field(DESC, "WS19144 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI19:144:MOTRVELCHOICE") { field(DESC, "WS19144 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI19:144:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI19:144:SYNCMOTPROFILE") { field(DESC, "WS19144 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI19:144:MOTPROFILE") field(LNK2, "WIRE:LI19:144:LVDTPROFILE") field(LNK3, "WIRE:LI19:144:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI19:144:CALIBSYNC") { field(DESC, "WS19144 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI19:144:MOTPROFILE") { field(DESC, "WS19144 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI19:144:POSN PP") } record(compress, "WIRE:LI19:144:LVDTPROFILE") { field(DESC, "WS19144 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI19:144:LVRAW PP") } record(subArray, "WIRE:LI19:144:SUBLPROF") { field(DESC, "WS19144 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI19:144:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI19:144:SUBMPROF") { field(DESC, "WS19144 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI19:144:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI19:144:PMOTPROFILE") { field(DESC, "WS19144 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI19:144:MOTPROFILE") field(FLNK, "WIRE:LI19:144:SUBMPROF") } record(waveform, "WIRE:LI19:144:PLVDTPROFILE") { field(DESC, "WS19144 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI19:144:LVDTPROFILE") field(FLNK, "WIRE:LI19:144:SUBLPROF") } record(ai, "WIRE:LI19:144:MOTRVALREST") { field(INP, "WIRE:LI19:144:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI19:144:MOTR",160,62,0,0,"WIRE:LI19:144:MOTR") #! Field("WIRE:LI19:144:MOTR.FLNK",16777215,1,"WIRE:LI19:144:MOTR.FLNK") #! Field("WIRE:LI19:144:MOTR.RDBL",16777215,1,"WIRE:LI19:144:MOTR.RDBL") #! Field("WIRE:LI19:144:MOTR.OFF",16777215,1,"WIRE:LI19:144:MOTR.OFF") #! Field("WIRE:LI19:144:MOTR.HLM",16777215,1,"WIRE:LI19:144:MOTR.HLM") #! Field("WIRE:LI19:144:MOTR.LLM",16777215,1,"WIRE:LI19:144:MOTR.LLM") #! Field("WIRE:LI19:144:MOTR.VELO",16777215,1,"WIRE:LI19:144:MOTR.VELO") #! Field("WIRE:LI19:144:MOTR.VAL",16777215,1,"WIRE:LI19:144:MOTR.VAL") #! Record("WIRE:LI19:144:POSN",1000,544,0,0,"WIRE:LI19:144:POSN") #! Field("WIRE:LI19:144:POSN.FLNK",16777215,1,"WIRE:LI19:144:POSN.FLNK") #! Field("WIRE:LI19:144:POSN.EOFF",16777215,0,"WIRE:LI19:144:POSN.EOFF") #! Field("WIRE:LI19:144:POSN.VAL",16777215,1,"WIRE:LI19:144:POSN.VAL") #! Record("WIRE:LI19:144:MASK",1340,1352,0,0,"WIRE:LI19:144:MASK") #! Field("WIRE:LI19:144:MASK.FLNK",16777215,1,"WIRE:LI19:144:MASK.FLNK") #! Record("WIRE:LI19:144:NEWOFFS",720,612,0,0,"WIRE:LI19:144:NEWOFFS") #! Field("WIRE:LI19:144:NEWOFFS.DOL",16777215,0,"WIRE:LI19:144:NEWOFFS.DOL") #! Link("WIRE:LI19:144:NEWOFFS.DOL","WIRE:LI19:144:MOTR.OFF") #! Field("WIRE:LI19:144:NEWOFFS.OUT",16777215,1,"WIRE:LI19:144:NEWOFFS.OUT") #! Link("WIRE:LI19:144:NEWOFFS.OUT","WIRE:LI19:144:POSN.EOFF") #! Record("WIRE:LI19:144:MOTRVAL",860,986,0,0,"WIRE:LI19:144:MOTRVAL") #! Field("WIRE:LI19:144:MOTRVAL.OUT",16777215,0,"WIRE:LI19:144:MOTRVAL.OUT") #! Link("WIRE:LI19:144:MOTRVAL.OUT","WIRE:LI19:144:MOTR.VAL") #! Field("WIRE:LI19:144:MOTRVAL.FLNK",16777215,0,"WIRE:LI19:144:MOTRVAL.FLNK") #! Link("WIRE:LI19:144:MOTRVAL.FLNK","WIRE:LI19:144:MOTR") #! Record("WIRE:LI19:144:MOTRHI",860,1238,0,0,"WIRE:LI19:144:MOTRHI") #! Field("WIRE:LI19:144:MOTRHI.DOL",16777215,0,"WIRE:LI19:144:MOTRHI.DOL") #! Link("WIRE:LI19:144:MOTRHI.DOL","WIRE:LI19:144:MOTR.HLM") #! Field("WIRE:LI19:144:MOTRHI.OUT",16777215,0,"WIRE:LI19:144:MOTRHI.OUT") #! Link("WIRE:LI19:144:MOTRHI.OUT","WIRE:LI19:144:MOTR.VAL") #! Field("WIRE:LI19:144:MOTRHI.FLNK",16777215,0,"WIRE:LI19:144:MOTRHI.FLNK") #! Link("WIRE:LI19:144:MOTRHI.FLNK","WIRE:LI19:144:MOTR") #! Record("WIRE:LI19:144:MOTRLO",860,1558,0,0,"WIRE:LI19:144:MOTRLO") #! Field("WIRE:LI19:144:MOTRLO.DOL",16777215,0,"WIRE:LI19:144:MOTRLO.DOL") #! Link("WIRE:LI19:144:MOTRLO.DOL","WIRE:LI19:144:MOTR.LLM") #! Field("WIRE:LI19:144:MOTRLO.OUT",16777215,0,"WIRE:LI19:144:MOTRLO.OUT") #! Link("WIRE:LI19:144:MOTRLO.OUT","WIRE:LI19:144:MOTR.VAL") #! Field("WIRE:LI19:144:MOTRLO.FLNK",16777215,0,"WIRE:LI19:144:MOTRLO.FLNK") #! Link("WIRE:LI19:144:MOTRLO.FLNK","WIRE:LI19:144:MOTR") #! Record("WIRE:LI19:144:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI19:144:MOTRVELCHOICE") #! Field("WIRE:LI19:144:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI19:144:MOTRVELCHOICE.OUT") #! Link("WIRE:LI19:144:MOTRVELCHOICE.OUT","WIRE:LI19:144:MOTR.VELO") #! Record("WIRE:LI19:144:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI19:144:SYNCMOTPROFILE") #! Field("WIRE:LI19:144:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI19:144:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI19:144:SYNCMOTPROFILE.LNK1","WIRE:LI19:144:MOTPROFILE") #! Field("WIRE:LI19:144:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI19:144:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI19:144:SYNCMOTPROFILE.LNK2","WIRE:LI19:144:LVDTPROFILE") #! Field("WIRE:LI19:144:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI19:144:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI19:144:SYNCMOTPROFILE.LNK3","WIRE:LI19:144:CALIBSYNC") #! Record("WIRE:LI19:144:CALIBSYNC",1980,860,0,0,"WIRE:LI19:144:CALIBSYNC") #! Record("WIRE:LI19:144:MOTPROFILE",1380,706,0,1,"WIRE:LI19:144:MOTPROFILE") #! Field("WIRE:LI19:144:MOTPROFILE.INP",16777215,0,"WIRE:LI19:144:MOTPROFILE.INP") #! Link("WIRE:LI19:144:MOTPROFILE.INP","WIRE:LI19:144:POSN.VAL") #! Field("WIRE:LI19:144:MOTPROFILE.VAL",16777215,0,"WIRE:LI19:144:MOTPROFILE.VAL") #! Record("WIRE:LI19:144:LVDTPROFILE",2000,566,0,0,"WIRE:LI19:144:LVDTPROFILE") #! Field("WIRE:LI19:144:LVDTPROFILE.INP",16777215,1,"WIRE:LI19:144:LVDTPROFILE.INP") #! Field("WIRE:LI19:144:LVDTPROFILE.VAL",16777215,1,"WIRE:LI19:144:LVDTPROFILE.VAL") #! Record("WIRE:LI19:144:SUBLPROF",2560,698,0,0,"WIRE:LI19:144:SUBLPROF") #! Field("WIRE:LI19:144:SUBLPROF.INP",16777215,0,"WIRE:LI19:144:SUBLPROF.INP") #! Link("WIRE:LI19:144:SUBLPROF.INP","WIRE:LI19:144:PLVDTPROFILE.VAL") #! Record("WIRE:LI19:144:SUBMPROF",1700,1078,0,0,"WIRE:LI19:144:SUBMPROF") #! Field("WIRE:LI19:144:SUBMPROF.INP",16777215,0,"WIRE:LI19:144:SUBMPROF.INP") #! Link("WIRE:LI19:144:SUBMPROF.INP","WIRE:LI19:144:PMOTPROFILE.VAL") #! Record("WIRE:LI19:144:PMOTPROFILE",1380,998,0,0,"WIRE:LI19:144:PMOTPROFILE") #! Field("WIRE:LI19:144:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI19:144:PMOTPROFILE.FLNK") #! Link("WIRE:LI19:144:PMOTPROFILE.FLNK","WIRE:LI19:144:SUBMPROF") #! Field("WIRE:LI19:144:PMOTPROFILE.VAL",16777215,1,"WIRE:LI19:144:PMOTPROFILE.VAL") #! Field("WIRE:LI19:144:PMOTPROFILE.INP",16777215,0,"WIRE:LI19:144:PMOTPROFILE.INP") #! Link("WIRE:LI19:144:PMOTPROFILE.INP","WIRE:LI19:144:MOTPROFILE.VAL") #! Record("WIRE:LI19:144:PLVDTPROFILE",2280,578,0,0,"WIRE:LI19:144:PLVDTPROFILE") #! Field("WIRE:LI19:144:PLVDTPROFILE.INP",16777215,0,"WIRE:LI19:144:PLVDTPROFILE.INP") #! Link("WIRE:LI19:144:PLVDTPROFILE.INP","WIRE:LI19:144:LVDTPROFILE.VAL") #! Field("WIRE:LI19:144:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI19:144:PLVDTPROFILE.FLNK") #! Link("WIRE:LI19:144:PLVDTPROFILE.FLNK","WIRE:LI19:144:SUBLPROF") #! Field("WIRE:LI19:144:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI19:144:PLVDTPROFILE.VAL") #! Record("WIRE:LI19:144:MOTRVALREST",500,914,0,0,"WIRE:LI19:144:MOTRVALREST") #! Field("WIRE:LI19:144:MOTRVALREST.INP",16777215,0,"WIRE:LI19:144:MOTRVALREST.INP") #! Link("WIRE:LI19:144:MOTRVALREST.INP","WIRE:LI19:144:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/2 record(motor, "WIRE:LI19:244:MOTR") { field(DESC, "WS19244 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 2)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI19:244:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI19:244:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI19:244 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI19:244:POSN") { field(DESC, "WS19244 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 2)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI19:244:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI19:244 (WS19244) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI19:244:MASK") { field(DESC, "WS19244 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI19:244:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI19:244 (WS19244) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI19:244:NEWOFFS") { field(DESC, "New WS19244 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:244:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:244:POSN.EOFF") } record(ao, "WIRE:LI19:244:MOTRVAL") { field(DESC, "WS19244 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI19:244:MOTR.VAL") field(FLNK, "WIRE:LI19:244:MOTR") } record(ao, "WIRE:LI19:244:MOTRHI") { field(DESC, "Move WS19244 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:244:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:244:MOTR.VAL") field(FLNK, "WIRE:LI19:244:MOTR") } record(ao, "WIRE:LI19:244:MOTRLO") { field(DESC, "Move WS19244 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:244:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:244:MOTR.VAL") field(FLNK, "WIRE:LI19:244:MOTR") } record(ao, "WIRE:LI19:244:RETRACT") { field(DESC, "WS19244 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI19:244:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI19:244:MOTR.VAL") field(FLNK, "WIRE:LI19:244:MOTR") } record(ai, "WIRE:LI19:244:RETRACT_POSN") { field(DESC, "WS19244 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI19:244:MOTRVELCHOICE") { field(DESC, "WS19244 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI19:244:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI19:244:SYNCMOTPROFILE") { field(DESC, "WS19244 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI19:244:MOTPROFILE") field(LNK2, "WIRE:LI19:244:LVDTPROFILE") field(LNK3, "WIRE:LI19:244:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI19:244:CALIBSYNC") { field(DESC, "WS19244 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI19:244:MOTPROFILE") { field(DESC, "WS19244 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI19:244:POSN PP") } record(compress, "WIRE:LI19:244:LVDTPROFILE") { field(DESC, "WS19244 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI19:244:LVRAW PP") } record(subArray, "WIRE:LI19:244:SUBLPROF") { field(DESC, "WS19244 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI19:244:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI19:244:SUBMPROF") { field(DESC, "WS19244 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI19:244:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI19:244:PMOTPROFILE") { field(DESC, "WS19244 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI19:244:MOTPROFILE") field(FLNK, "WIRE:LI19:244:SUBMPROF") } record(waveform, "WIRE:LI19:244:PLVDTPROFILE") { field(DESC, "WS19244 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI19:244:LVDTPROFILE") field(FLNK, "WIRE:LI19:244:SUBLPROF") } record(ai, "WIRE:LI19:244:MOTRVALREST") { field(INP, "WIRE:LI19:244:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI19:244:MOTR",160,62,0,0,"WIRE:LI19:244:MOTR") #! Field("WIRE:LI19:244:MOTR.FLNK",16777215,1,"WIRE:LI19:244:MOTR.FLNK") #! Field("WIRE:LI19:244:MOTR.RDBL",16777215,1,"WIRE:LI19:244:MOTR.RDBL") #! Field("WIRE:LI19:244:MOTR.OFF",16777215,1,"WIRE:LI19:244:MOTR.OFF") #! Field("WIRE:LI19:244:MOTR.HLM",16777215,1,"WIRE:LI19:244:MOTR.HLM") #! Field("WIRE:LI19:244:MOTR.LLM",16777215,1,"WIRE:LI19:244:MOTR.LLM") #! Field("WIRE:LI19:244:MOTR.VELO",16777215,1,"WIRE:LI19:244:MOTR.VELO") #! Field("WIRE:LI19:244:MOTR.VAL",16777215,1,"WIRE:LI19:244:MOTR.VAL") #! Record("WIRE:LI19:244:POSN",1000,544,0,0,"WIRE:LI19:244:POSN") #! Field("WIRE:LI19:244:POSN.FLNK",16777215,1,"WIRE:LI19:244:POSN.FLNK") #! Field("WIRE:LI19:244:POSN.EOFF",16777215,0,"WIRE:LI19:244:POSN.EOFF") #! Field("WIRE:LI19:244:POSN.VAL",16777215,1,"WIRE:LI19:244:POSN.VAL") #! Record("WIRE:LI19:244:MASK",1340,1352,0,0,"WIRE:LI19:244:MASK") #! Field("WIRE:LI19:244:MASK.FLNK",16777215,1,"WIRE:LI19:244:MASK.FLNK") #! Record("WIRE:LI19:244:NEWOFFS",720,612,0,0,"WIRE:LI19:244:NEWOFFS") #! Field("WIRE:LI19:244:NEWOFFS.DOL",16777215,0,"WIRE:LI19:244:NEWOFFS.DOL") #! Link("WIRE:LI19:244:NEWOFFS.DOL","WIRE:LI19:244:MOTR.OFF") #! Field("WIRE:LI19:244:NEWOFFS.OUT",16777215,1,"WIRE:LI19:244:NEWOFFS.OUT") #! Link("WIRE:LI19:244:NEWOFFS.OUT","WIRE:LI19:244:POSN.EOFF") #! Record("WIRE:LI19:244:MOTRVAL",860,986,0,0,"WIRE:LI19:244:MOTRVAL") #! Field("WIRE:LI19:244:MOTRVAL.OUT",16777215,0,"WIRE:LI19:244:MOTRVAL.OUT") #! Link("WIRE:LI19:244:MOTRVAL.OUT","WIRE:LI19:244:MOTR.VAL") #! Field("WIRE:LI19:244:MOTRVAL.FLNK",16777215,0,"WIRE:LI19:244:MOTRVAL.FLNK") #! Link("WIRE:LI19:244:MOTRVAL.FLNK","WIRE:LI19:244:MOTR") #! Record("WIRE:LI19:244:MOTRHI",860,1238,0,0,"WIRE:LI19:244:MOTRHI") #! Field("WIRE:LI19:244:MOTRHI.DOL",16777215,0,"WIRE:LI19:244:MOTRHI.DOL") #! Link("WIRE:LI19:244:MOTRHI.DOL","WIRE:LI19:244:MOTR.HLM") #! Field("WIRE:LI19:244:MOTRHI.OUT",16777215,0,"WIRE:LI19:244:MOTRHI.OUT") #! Link("WIRE:LI19:244:MOTRHI.OUT","WIRE:LI19:244:MOTR.VAL") #! Field("WIRE:LI19:244:MOTRHI.FLNK",16777215,0,"WIRE:LI19:244:MOTRHI.FLNK") #! Link("WIRE:LI19:244:MOTRHI.FLNK","WIRE:LI19:244:MOTR") #! Record("WIRE:LI19:244:MOTRLO",860,1558,0,0,"WIRE:LI19:244:MOTRLO") #! Field("WIRE:LI19:244:MOTRLO.DOL",16777215,0,"WIRE:LI19:244:MOTRLO.DOL") #! Link("WIRE:LI19:244:MOTRLO.DOL","WIRE:LI19:244:MOTR.LLM") #! Field("WIRE:LI19:244:MOTRLO.OUT",16777215,0,"WIRE:LI19:244:MOTRLO.OUT") #! Link("WIRE:LI19:244:MOTRLO.OUT","WIRE:LI19:244:MOTR.VAL") #! Field("WIRE:LI19:244:MOTRLO.FLNK",16777215,0,"WIRE:LI19:244:MOTRLO.FLNK") #! Link("WIRE:LI19:244:MOTRLO.FLNK","WIRE:LI19:244:MOTR") #! Record("WIRE:LI19:244:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI19:244:MOTRVELCHOICE") #! Field("WIRE:LI19:244:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI19:244:MOTRVELCHOICE.OUT") #! Link("WIRE:LI19:244:MOTRVELCHOICE.OUT","WIRE:LI19:244:MOTR.VELO") #! Record("WIRE:LI19:244:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI19:244:SYNCMOTPROFILE") #! Field("WIRE:LI19:244:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI19:244:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI19:244:SYNCMOTPROFILE.LNK1","WIRE:LI19:244:MOTPROFILE") #! Field("WIRE:LI19:244:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI19:244:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI19:244:SYNCMOTPROFILE.LNK2","WIRE:LI19:244:LVDTPROFILE") #! Field("WIRE:LI19:244:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI19:244:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI19:244:SYNCMOTPROFILE.LNK3","WIRE:LI19:244:CALIBSYNC") #! Record("WIRE:LI19:244:CALIBSYNC",1980,860,0,0,"WIRE:LI19:244:CALIBSYNC") #! Record("WIRE:LI19:244:MOTPROFILE",1380,706,0,1,"WIRE:LI19:244:MOTPROFILE") #! Field("WIRE:LI19:244:MOTPROFILE.INP",16777215,0,"WIRE:LI19:244:MOTPROFILE.INP") #! Link("WIRE:LI19:244:MOTPROFILE.INP","WIRE:LI19:244:POSN.VAL") #! Field("WIRE:LI19:244:MOTPROFILE.VAL",16777215,0,"WIRE:LI19:244:MOTPROFILE.VAL") #! Record("WIRE:LI19:244:LVDTPROFILE",2000,566,0,0,"WIRE:LI19:244:LVDTPROFILE") #! Field("WIRE:LI19:244:LVDTPROFILE.INP",16777215,1,"WIRE:LI19:244:LVDTPROFILE.INP") #! Field("WIRE:LI19:244:LVDTPROFILE.VAL",16777215,1,"WIRE:LI19:244:LVDTPROFILE.VAL") #! Record("WIRE:LI19:244:SUBLPROF",2560,698,0,0,"WIRE:LI19:244:SUBLPROF") #! Field("WIRE:LI19:244:SUBLPROF.INP",16777215,0,"WIRE:LI19:244:SUBLPROF.INP") #! Link("WIRE:LI19:244:SUBLPROF.INP","WIRE:LI19:244:PLVDTPROFILE.VAL") #! Record("WIRE:LI19:244:SUBMPROF",1700,1078,0,0,"WIRE:LI19:244:SUBMPROF") #! Field("WIRE:LI19:244:SUBMPROF.INP",16777215,0,"WIRE:LI19:244:SUBMPROF.INP") #! Link("WIRE:LI19:244:SUBMPROF.INP","WIRE:LI19:244:PMOTPROFILE.VAL") #! Record("WIRE:LI19:244:PMOTPROFILE",1380,998,0,0,"WIRE:LI19:244:PMOTPROFILE") #! Field("WIRE:LI19:244:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI19:244:PMOTPROFILE.FLNK") #! Link("WIRE:LI19:244:PMOTPROFILE.FLNK","WIRE:LI19:244:SUBMPROF") #! Field("WIRE:LI19:244:PMOTPROFILE.VAL",16777215,1,"WIRE:LI19:244:PMOTPROFILE.VAL") #! Field("WIRE:LI19:244:PMOTPROFILE.INP",16777215,0,"WIRE:LI19:244:PMOTPROFILE.INP") #! Link("WIRE:LI19:244:PMOTPROFILE.INP","WIRE:LI19:244:MOTPROFILE.VAL") #! Record("WIRE:LI19:244:PLVDTPROFILE",2280,578,0,0,"WIRE:LI19:244:PLVDTPROFILE") #! Field("WIRE:LI19:244:PLVDTPROFILE.INP",16777215,0,"WIRE:LI19:244:PLVDTPROFILE.INP") #! Link("WIRE:LI19:244:PLVDTPROFILE.INP","WIRE:LI19:244:LVDTPROFILE.VAL") #! Field("WIRE:LI19:244:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI19:244:PLVDTPROFILE.FLNK") #! Link("WIRE:LI19:244:PLVDTPROFILE.FLNK","WIRE:LI19:244:SUBLPROF") #! Field("WIRE:LI19:244:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI19:244:PLVDTPROFILE.VAL") #! Record("WIRE:LI19:244:MOTRVALREST",500,914,0,0,"WIRE:LI19:244:MOTRVALREST") #! Field("WIRE:LI19:244:MOTRVALREST.INP",16777215,0,"WIRE:LI19:244:MOTRVALREST.INP") #! Link("WIRE:LI19:244:MOTRVALREST.INP","WIRE:LI19:244:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/3 record(motor, "WIRE:LI19:344:MOTR") { field(DESC, "WS19344 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 3)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI19:344:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI19:344:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI19:344 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI19:344:POSN") { field(DESC, "WS19344 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 3)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI19:344:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI19:344 (WS19344) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI19:344:MASK") { field(DESC, "WS19344 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI19:344:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI19:344 (WS19344) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI19:344:NEWOFFS") { field(DESC, "New WS19344 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:344:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:344:POSN.EOFF") } record(ao, "WIRE:LI19:344:MOTRVAL") { field(DESC, "WS19344 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI19:344:MOTR.VAL") field(FLNK, "WIRE:LI19:344:MOTR") } record(ao, "WIRE:LI19:344:MOTRHI") { field(DESC, "Move WS19344 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:344:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:344:MOTR.VAL") field(FLNK, "WIRE:LI19:344:MOTR") } record(ao, "WIRE:LI19:344:MOTRLO") { field(DESC, "Move WS19344 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI19:344:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI19:344:MOTR.VAL") field(FLNK, "WIRE:LI19:344:MOTR") } record(ao, "WIRE:LI19:344:RETRACT") { field(DESC, "WS19344 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI19:344:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI19:344:MOTR.VAL") field(FLNK, "WIRE:LI19:344:MOTR") } record(ai, "WIRE:LI19:344:RETRACT_POSN") { field(DESC, "WS19344 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI19:344:MOTRVELCHOICE") { field(DESC, "WS19344 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI19:344:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI19:344:SYNCMOTPROFILE") { field(DESC, "WS19344 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI19:344:MOTPROFILE") field(LNK2, "WIRE:LI19:344:LVDTPROFILE") field(LNK3, "WIRE:LI19:344:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI19:344:CALIBSYNC") { field(DESC, "WS19344 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI19:344:MOTPROFILE") { field(DESC, "WS19344 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI19:344:POSN PP") } record(compress, "WIRE:LI19:344:LVDTPROFILE") { field(DESC, "WS19344 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI19:344:LVRAW PP") } record(subArray, "WIRE:LI19:344:SUBLPROF") { field(DESC, "WS19344 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI19:344:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI19:344:SUBMPROF") { field(DESC, "WS19344 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI19:344:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI19:344:PMOTPROFILE") { field(DESC, "WS19344 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI19:344:MOTPROFILE") field(FLNK, "WIRE:LI19:344:SUBMPROF") } record(waveform, "WIRE:LI19:344:PLVDTPROFILE") { field(DESC, "WS19344 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI19:344:LVDTPROFILE") field(FLNK, "WIRE:LI19:344:SUBLPROF") } record(ai, "WIRE:LI19:344:MOTRVALREST") { field(INP, "WIRE:LI19:344:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI19:344:MOTR",160,62,0,0,"WIRE:LI19:344:MOTR") #! Field("WIRE:LI19:344:MOTR.FLNK",16777215,1,"WIRE:LI19:344:MOTR.FLNK") #! Field("WIRE:LI19:344:MOTR.RDBL",16777215,1,"WIRE:LI19:344:MOTR.RDBL") #! Field("WIRE:LI19:344:MOTR.OFF",16777215,1,"WIRE:LI19:344:MOTR.OFF") #! Field("WIRE:LI19:344:MOTR.HLM",16777215,1,"WIRE:LI19:344:MOTR.HLM") #! Field("WIRE:LI19:344:MOTR.LLM",16777215,1,"WIRE:LI19:344:MOTR.LLM") #! Field("WIRE:LI19:344:MOTR.VELO",16777215,1,"WIRE:LI19:344:MOTR.VELO") #! Field("WIRE:LI19:344:MOTR.VAL",16777215,1,"WIRE:LI19:344:MOTR.VAL") #! Record("WIRE:LI19:344:POSN",1000,544,0,0,"WIRE:LI19:344:POSN") #! Field("WIRE:LI19:344:POSN.FLNK",16777215,1,"WIRE:LI19:344:POSN.FLNK") #! Field("WIRE:LI19:344:POSN.EOFF",16777215,0,"WIRE:LI19:344:POSN.EOFF") #! Field("WIRE:LI19:344:POSN.VAL",16777215,1,"WIRE:LI19:344:POSN.VAL") #! Record("WIRE:LI19:344:MASK",1340,1352,0,0,"WIRE:LI19:344:MASK") #! Field("WIRE:LI19:344:MASK.FLNK",16777215,1,"WIRE:LI19:344:MASK.FLNK") #! Record("WIRE:LI19:344:NEWOFFS",720,612,0,0,"WIRE:LI19:344:NEWOFFS") #! Field("WIRE:LI19:344:NEWOFFS.DOL",16777215,0,"WIRE:LI19:344:NEWOFFS.DOL") #! Link("WIRE:LI19:344:NEWOFFS.DOL","WIRE:LI19:344:MOTR.OFF") #! Field("WIRE:LI19:344:NEWOFFS.OUT",16777215,1,"WIRE:LI19:344:NEWOFFS.OUT") #! Link("WIRE:LI19:344:NEWOFFS.OUT","WIRE:LI19:344:POSN.EOFF") #! Record("WIRE:LI19:344:MOTRVAL",860,986,0,0,"WIRE:LI19:344:MOTRVAL") #! Field("WIRE:LI19:344:MOTRVAL.OUT",16777215,0,"WIRE:LI19:344:MOTRVAL.OUT") #! Link("WIRE:LI19:344:MOTRVAL.OUT","WIRE:LI19:344:MOTR.VAL") #! Field("WIRE:LI19:344:MOTRVAL.FLNK",16777215,0,"WIRE:LI19:344:MOTRVAL.FLNK") #! Link("WIRE:LI19:344:MOTRVAL.FLNK","WIRE:LI19:344:MOTR") #! Record("WIRE:LI19:344:MOTRHI",860,1238,0,0,"WIRE:LI19:344:MOTRHI") #! Field("WIRE:LI19:344:MOTRHI.DOL",16777215,0,"WIRE:LI19:344:MOTRHI.DOL") #! Link("WIRE:LI19:344:MOTRHI.DOL","WIRE:LI19:344:MOTR.HLM") #! Field("WIRE:LI19:344:MOTRHI.OUT",16777215,0,"WIRE:LI19:344:MOTRHI.OUT") #! Link("WIRE:LI19:344:MOTRHI.OUT","WIRE:LI19:344:MOTR.VAL") #! Field("WIRE:LI19:344:MOTRHI.FLNK",16777215,0,"WIRE:LI19:344:MOTRHI.FLNK") #! Link("WIRE:LI19:344:MOTRHI.FLNK","WIRE:LI19:344:MOTR") #! Record("WIRE:LI19:344:MOTRLO",860,1558,0,0,"WIRE:LI19:344:MOTRLO") #! Field("WIRE:LI19:344:MOTRLO.DOL",16777215,0,"WIRE:LI19:344:MOTRLO.DOL") #! Link("WIRE:LI19:344:MOTRLO.DOL","WIRE:LI19:344:MOTR.LLM") #! Field("WIRE:LI19:344:MOTRLO.OUT",16777215,0,"WIRE:LI19:344:MOTRLO.OUT") #! Link("WIRE:LI19:344:MOTRLO.OUT","WIRE:LI19:344:MOTR.VAL") #! Field("WIRE:LI19:344:MOTRLO.FLNK",16777215,0,"WIRE:LI19:344:MOTRLO.FLNK") #! Link("WIRE:LI19:344:MOTRLO.FLNK","WIRE:LI19:344:MOTR") #! Record("WIRE:LI19:344:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI19:344:MOTRVELCHOICE") #! Field("WIRE:LI19:344:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI19:344:MOTRVELCHOICE.OUT") #! Link("WIRE:LI19:344:MOTRVELCHOICE.OUT","WIRE:LI19:344:MOTR.VELO") #! Record("WIRE:LI19:344:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI19:344:SYNCMOTPROFILE") #! Field("WIRE:LI19:344:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI19:344:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI19:344:SYNCMOTPROFILE.LNK1","WIRE:LI19:344:MOTPROFILE") #! Field("WIRE:LI19:344:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI19:344:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI19:344:SYNCMOTPROFILE.LNK2","WIRE:LI19:344:LVDTPROFILE") #! Field("WIRE:LI19:344:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI19:344:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI19:344:SYNCMOTPROFILE.LNK3","WIRE:LI19:344:CALIBSYNC") #! Record("WIRE:LI19:344:CALIBSYNC",1980,860,0,0,"WIRE:LI19:344:CALIBSYNC") #! Record("WIRE:LI19:344:MOTPROFILE",1380,706,0,1,"WIRE:LI19:344:MOTPROFILE") #! Field("WIRE:LI19:344:MOTPROFILE.INP",16777215,0,"WIRE:LI19:344:MOTPROFILE.INP") #! Link("WIRE:LI19:344:MOTPROFILE.INP","WIRE:LI19:344:POSN.VAL") #! Field("WIRE:LI19:344:MOTPROFILE.VAL",16777215,0,"WIRE:LI19:344:MOTPROFILE.VAL") #! Record("WIRE:LI19:344:LVDTPROFILE",2000,566,0,0,"WIRE:LI19:344:LVDTPROFILE") #! Field("WIRE:LI19:344:LVDTPROFILE.INP",16777215,1,"WIRE:LI19:344:LVDTPROFILE.INP") #! Field("WIRE:LI19:344:LVDTPROFILE.VAL",16777215,1,"WIRE:LI19:344:LVDTPROFILE.VAL") #! Record("WIRE:LI19:344:SUBLPROF",2560,698,0,0,"WIRE:LI19:344:SUBLPROF") #! Field("WIRE:LI19:344:SUBLPROF.INP",16777215,0,"WIRE:LI19:344:SUBLPROF.INP") #! Link("WIRE:LI19:344:SUBLPROF.INP","WIRE:LI19:344:PLVDTPROFILE.VAL") #! Record("WIRE:LI19:344:SUBMPROF",1700,1078,0,0,"WIRE:LI19:344:SUBMPROF") #! Field("WIRE:LI19:344:SUBMPROF.INP",16777215,0,"WIRE:LI19:344:SUBMPROF.INP") #! Link("WIRE:LI19:344:SUBMPROF.INP","WIRE:LI19:344:PMOTPROFILE.VAL") #! Record("WIRE:LI19:344:PMOTPROFILE",1380,998,0,0,"WIRE:LI19:344:PMOTPROFILE") #! Field("WIRE:LI19:344:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI19:344:PMOTPROFILE.FLNK") #! Link("WIRE:LI19:344:PMOTPROFILE.FLNK","WIRE:LI19:344:SUBMPROF") #! Field("WIRE:LI19:344:PMOTPROFILE.VAL",16777215,1,"WIRE:LI19:344:PMOTPROFILE.VAL") #! Field("WIRE:LI19:344:PMOTPROFILE.INP",16777215,0,"WIRE:LI19:344:PMOTPROFILE.INP") #! Link("WIRE:LI19:344:PMOTPROFILE.INP","WIRE:LI19:344:MOTPROFILE.VAL") #! Record("WIRE:LI19:344:PLVDTPROFILE",2280,578,0,0,"WIRE:LI19:344:PLVDTPROFILE") #! Field("WIRE:LI19:344:PLVDTPROFILE.INP",16777215,0,"WIRE:LI19:344:PLVDTPROFILE.INP") #! Link("WIRE:LI19:344:PLVDTPROFILE.INP","WIRE:LI19:344:LVDTPROFILE.VAL") #! Field("WIRE:LI19:344:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI19:344:PLVDTPROFILE.FLNK") #! Link("WIRE:LI19:344:PLVDTPROFILE.FLNK","WIRE:LI19:344:SUBLPROF") #! Field("WIRE:LI19:344:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI19:344:PLVDTPROFILE.VAL") #! Record("WIRE:LI19:344:MOTRVALREST",500,914,0,0,"WIRE:LI19:344:MOTRVALREST") #! Field("WIRE:LI19:344:MOTRVALREST.INP",16777215,0,"WIRE:LI19:344:MOTRVALREST.INP") #! Link("WIRE:LI19:344:MOTRVALREST.INP","WIRE:LI19:344:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-02/0 record(motor, "COLL:LI18:961:MOTR") { field(DESC, "CX1896 Coll Left Jaw Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "8") field(VBAS, "2") field(VMAX, "8") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-02, 0)") field(MRES, "0.005") field(SREV, "400") field(PREC, "4") field(EGU, "mm") field(DHLM, "10.00") field(HOPR, "10.00") field(DLLM, "-55.00") field(LOPR, "-55.00") field(DLY, "0") field(TWV, "1.0") field(SET, "1") field(RDBD, "0.2") field(FOFF, "Frozen") field(FLNK, "COLL:LI18:961:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "2") field(BACC, "0.5") field(RDBL, "COLL:LI18:961:LVPOS") info(autosaveFields, "DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV HLM LLM") } # Position of motor on COLL:LI18:961 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "COLL:LI18:961:POSN") { field(DESC, "CX1896 Current Position") field(DTYP, "asynInt32") field(EGU, "mm") field(INP, "@asyn(Hy8601-02 0)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.005") field(PREC, "4") field(TSE, "-1") } # # This record contains a simple value that changes per # beam pulse; when COLL:LI18:961 (CX1896) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "COLL:LI18:961:MASK") { field(DESC, "CX1896 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(TSE, "-1") } # # This record takes the calibration offset from # COLL:LI18:961 (CX1896) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "COLL:LI18:961:NEWOFFS") { field(DESC, "New CX1896 Cal") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:961:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:961:POSN.EOFF") } record(ao, "COLL:LI18:961:MOTRVAL") { field(DESC, "CX1896 Value Proxy") field(EGU, "mm") field(OMSL, "supervisory") field(DRVH, "10.00") field(DRVL, "-55.00") field(SCAN, "Passive") field(OUT, "COLL:LI18:961:MOTR.VAL") field(FLNK, "COLL:LI18:961:MOTR") } record(ao, "COLL:LI18:961:MOTRHI") { field(DESC, "Move CX1896 High") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:961:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:961:MOTR.VAL") field(FLNK, "COLL:LI18:961:MOTR") } record(ao, "COLL:LI18:961:MOTRLO") { field(DESC, "Move CX1896 Low") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:961:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:961:MOTR.VAL") field(FLNK, "COLL:LI18:961:MOTR") } record(mbbo, "COLL:LI18:961:MOTRVELCHOICE") { field(DESC, "CX1896 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "COLL:LI18:961:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "5") field(ONST, "Maximum") field(ONVL, "8") field(TWST, "Medium") field(TWVL, "5") field(THST, "Slow") field(THVL, "3") } record(fanout, "COLL:LI18:961:SYNCMOTPROFILE") { field(DESC, "CX1896 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "COLL:LI18:961:MOTPROFILE") field(LNK2, "COLL:LI18:961:LVDTPROFILE") field(LNK3, "COLL:LI18:961:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "COLL:LI18:961:CALIBSYNC") { field(DESC, "CX1896 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "COLL:LI18:961:MOTPROFILE") { field(DESC, "CX1896 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:961:POSN PP") } record(compress, "COLL:LI18:961:LVDTPROFILE") { field(DESC, "CX1896 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:961:LVRAW PP") } record(subArray, "COLL:LI18:961:SUBLPROF") { field(DESC, "CX1896 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:961:PLVDTPROFILE.VAL") } record(subArray, "COLL:LI18:961:SUBMPROF") { field(DESC, "CX1896 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:961:PMOTPROFILE.VAL") } record(waveform, "COLL:LI18:961:PMOTPROFILE") { field(DESC, "CX1896 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:961:MOTPROFILE") field(FLNK, "COLL:LI18:961:SUBMPROF") } record(waveform, "COLL:LI18:961:PLVDTPROFILE") { field(DESC, "CX1896 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:961:LVDTPROFILE") field(FLNK, "COLL:LI18:961:SUBLPROF") } record(ai, "COLL:LI18:961:MOTRVALREST") { field(INP, "COLL:LI18:961:MOTR") } #! Further lines contain data used by VisualDCT #! View(149,96,0.7) #! Record("COLL:LI18:961:MOTR",340,130,0,0,"COLL:LI18:961:MOTR") #! Field("COLL:LI18:961:MOTR.OFF",16777215,1,"COLL:LI18:961:MOTR.OFF") #! Field("COLL:LI18:961:MOTR.VAL",16777215,1,"COLL:LI18:961:MOTR.VAL") #! Field("COLL:LI18:961:MOTR.HLM",16777215,1,"COLL:LI18:961:MOTR.HLM") #! Field("COLL:LI18:961:MOTR.LLM",16777215,1,"COLL:LI18:961:MOTR.LLM") #! Field("COLL:LI18:961:MOTR.VELO",16777215,1,"COLL:LI18:961:MOTR.VELO") #! Field("COLL:LI18:961:MOTR.RDBL",16777215,1,"COLL:LI18:961:MOTR.RDBL") #! Field("COLL:LI18:961:MOTR.FLNK",16777215,1,"COLL:LI18:961:MOTR.FLNK") #! Link("COLL:LI18:961:MOTR.FLNK","COLL:LI18:961:MOTRVALREST") #! Record("COLL:LI18:961:POSN",1060,842,0,0,"COLL:LI18:961:POSN") #! Field("COLL:LI18:961:POSN.EOFF",16777215,1,"COLL:LI18:961:POSN.EOFF") #! Field("COLL:LI18:961:POSN.VAL",16777215,1,"COLL:LI18:961:POSN.VAL") #! Record("COLL:LI18:961:MASK",2440,273,0,0,"COLL:LI18:961:MASK") #! Record("COLL:LI18:961:NEWOFFS",820,919,0,0,"COLL:LI18:961:NEWOFFS") #! Field("COLL:LI18:961:NEWOFFS.DOL",16777215,0,"COLL:LI18:961:NEWOFFS.DOL") #! Link("COLL:LI18:961:NEWOFFS.DOL","COLL:LI18:961:MOTR.OFF") #! Field("COLL:LI18:961:NEWOFFS.OUT",16777215,1,"COLL:LI18:961:NEWOFFS.OUT") #! Link("COLL:LI18:961:NEWOFFS.OUT","COLL:LI18:961:POSN.EOFF") #! Record("COLL:LI18:961:MOTRVAL",760,1893,0,0,"COLL:LI18:961:MOTRVAL") #! Field("COLL:LI18:961:MOTRVAL.OUT",16777215,0,"COLL:LI18:961:MOTRVAL.OUT") #! Link("COLL:LI18:961:MOTRVAL.OUT","COLL:LI18:961:MOTR.VAL") #! Field("COLL:LI18:961:MOTRVAL.FLNK",16777215,0,"COLL:LI18:961:MOTRVAL.FLNK") #! Link("COLL:LI18:961:MOTRVAL.FLNK","COLL:LI18:961:MOTR") #! Record("COLL:LI18:961:MOTRHI",740,2685,0,0,"COLL:LI18:961:MOTRHI") #! Field("COLL:LI18:961:MOTRHI.DOL",16777215,0,"COLL:LI18:961:MOTRHI.DOL") #! Link("COLL:LI18:961:MOTRHI.DOL","COLL:LI18:961:MOTR.HLM") #! Field("COLL:LI18:961:MOTRHI.OUT",16777215,0,"COLL:LI18:961:MOTRHI.OUT") #! Link("COLL:LI18:961:MOTRHI.OUT","COLL:LI18:961:MOTR.VAL") #! Field("COLL:LI18:961:MOTRHI.FLNK",16777215,0,"COLL:LI18:961:MOTRHI.FLNK") #! Link("COLL:LI18:961:MOTRHI.FLNK","COLL:LI18:961:MOTR") #! Record("COLL:LI18:961:MOTRLO",720,2265,0,0,"COLL:LI18:961:MOTRLO") #! Field("COLL:LI18:961:MOTRLO.DOL",16777215,0,"COLL:LI18:961:MOTRLO.DOL") #! Link("COLL:LI18:961:MOTRLO.DOL","COLL:LI18:961:MOTR.LLM") #! Field("COLL:LI18:961:MOTRLO.OUT",16777215,0,"COLL:LI18:961:MOTRLO.OUT") #! Link("COLL:LI18:961:MOTRLO.OUT","COLL:LI18:961:MOTR.VAL") #! Field("COLL:LI18:961:MOTRLO.FLNK",16777215,0,"COLL:LI18:961:MOTRLO.FLNK") #! Link("COLL:LI18:961:MOTRLO.FLNK","COLL:LI18:961:MOTR") #! Record("COLL:LI18:961:MOTRVELCHOICE",740,1428,0,0,"COLL:LI18:961:MOTRVELCHOICE") #! Field("COLL:LI18:961:MOTRVELCHOICE.OUT",16777215,0,"COLL:LI18:961:MOTRVELCHOICE.OUT") #! Link("COLL:LI18:961:MOTRVELCHOICE.OUT","COLL:LI18:961:MOTR.VELO") #! Record("COLL:LI18:961:SYNCMOTPROFILE",640,128,0,0,"COLL:LI18:961:SYNCMOTPROFILE") #! Field("COLL:LI18:961:SYNCMOTPROFILE.LNK3",16777215,1,"COLL:LI18:961:SYNCMOTPROFILE.LNK3") #! Link("COLL:LI18:961:SYNCMOTPROFILE.LNK3","COLL:LI18:961:CALIBSYNC") #! Field("COLL:LI18:961:SYNCMOTPROFILE.LNK2",16777215,1,"COLL:LI18:961:SYNCMOTPROFILE.LNK2") #! Link("COLL:LI18:961:SYNCMOTPROFILE.LNK2","COLL:LI18:961:LVDTPROFILE") #! Field("COLL:LI18:961:SYNCMOTPROFILE.LNK1",16777215,1,"COLL:LI18:961:SYNCMOTPROFILE.LNK1") #! Link("COLL:LI18:961:SYNCMOTPROFILE.LNK1","COLL:LI18:961:MOTPROFILE") #! Record("COLL:LI18:961:CALIBSYNC",1440,72,0,0,"COLL:LI18:961:CALIBSYNC") #! Record("COLL:LI18:961:MOTPROFILE",1380,838,0,0,"COLL:LI18:961:MOTPROFILE") #! Field("COLL:LI18:961:MOTPROFILE.VAL",16777215,1,"COLL:LI18:961:MOTPROFILE.VAL") #! Field("COLL:LI18:961:MOTPROFILE.INP",16777215,0,"COLL:LI18:961:MOTPROFILE.INP") #! Link("COLL:LI18:961:MOTPROFILE.INP","COLL:LI18:961:POSN.VAL") #! Record("COLL:LI18:961:LVDTPROFILE",1460,258,0,0,"COLL:LI18:961:LVDTPROFILE") #! Field("COLL:LI18:961:LVDTPROFILE.INP",16777215,1,"COLL:LI18:961:LVDTPROFILE.INP") #! Field("COLL:LI18:961:LVDTPROFILE.VAL",16777215,1,"COLL:LI18:961:LVDTPROFILE.VAL") #! Record("COLL:LI18:961:SUBLPROF",2140,288,0,0,"COLL:LI18:961:SUBLPROF") #! Field("COLL:LI18:961:SUBLPROF.INP",16777215,0,"COLL:LI18:961:SUBLPROF.INP") #! Link("COLL:LI18:961:SUBLPROF.INP","COLL:LI18:961:PLVDTPROFILE.VAL") #! Record("COLL:LI18:961:SUBMPROF",2260,908,0,0,"COLL:LI18:961:SUBMPROF") #! Field("COLL:LI18:961:SUBMPROF.INP",16777215,0,"COLL:LI18:961:SUBMPROF.INP") #! Link("COLL:LI18:961:SUBMPROF.INP","COLL:LI18:961:PMOTPROFILE.VAL") #! Record("COLL:LI18:961:PMOTPROFILE",1660,808,0,0,"COLL:LI18:961:PMOTPROFILE") #! Field("COLL:LI18:961:PMOTPROFILE.INP",16777215,0,"COLL:LI18:961:PMOTPROFILE.INP") #! Link("COLL:LI18:961:PMOTPROFILE.INP","COLL:LI18:961:MOTPROFILE.VAL") #! Field("COLL:LI18:961:PMOTPROFILE.VAL",16777215,1,"COLL:LI18:961:PMOTPROFILE.VAL") #! Field("COLL:LI18:961:PMOTPROFILE.FLNK",16777215,1,"COLL:LI18:961:PMOTPROFILE.FLNK") #! Link("COLL:LI18:961:PMOTPROFILE.FLNK","COLL:LI18:961:SUBMPROF") #! Record("COLL:LI18:961:PLVDTPROFILE",1800,248,0,0,"COLL:LI18:961:PLVDTPROFILE") #! Field("COLL:LI18:961:PLVDTPROFILE.INP",16777215,0,"COLL:LI18:961:PLVDTPROFILE.INP") #! Link("COLL:LI18:961:PLVDTPROFILE.INP","COLL:LI18:961:LVDTPROFILE.VAL") #! Field("COLL:LI18:961:PLVDTPROFILE.FLNK",16777215,1,"COLL:LI18:961:PLVDTPROFILE.FLNK") #! Link("COLL:LI18:961:PLVDTPROFILE.FLNK","COLL:LI18:961:SUBLPROF") #! Field("COLL:LI18:961:PLVDTPROFILE.VAL",16777215,1,"COLL:LI18:961:PLVDTPROFILE.VAL") #! Record("COLL:LI18:961:MOTRVALREST",800,709,0,0,"COLL:LI18:961:MOTRVALREST") #! Field("COLL:LI18:961:MOTRVALREST.INP",16777215,0,"COLL:LI18:961:MOTRVALREST.INP") #! Link("COLL:LI18:961:MOTRVALREST.INP","COLL:LI18:961:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-02/1 record(motor, "COLL:LI18:960:MOTR") { field(DESC, "CX1896 Coll Right Jaw Motion") field(SCAN, "Passive") field(DIR, "Neg") field(DTYP, "asynMotor") field(VELO, "8") field(VBAS, "2") field(VMAX, "8") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-02, 1)") field(MRES, "0.005") field(SREV, "400") field(PREC, "4") field(EGU, "mm") field(DHLM, "10.00") field(HOPR, "10.00") field(DLLM, "-55.00") field(LOPR, "-55.00") field(DLY, "0") field(TWV, "1.0") field(SET, "1") field(RDBD, "0.2") field(FOFF, "Frozen") field(FLNK, "COLL:LI18:960:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "2") field(BACC, "0.5") field(RDBL, "COLL:LI18:960:LVPOS") info(autosaveFields, "DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV HLM LLM") } # Position of motor on COLL:LI18:960 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "COLL:LI18:960:POSN") { field(DESC, "CX1896 Current Position") field(DTYP, "asynInt32") field(EGU, "mm") field(INP, "@asyn(Hy8601-02 1)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "-0.005") field(PREC, "4") field(TSE, "-1") } # # This record contains a simple value that changes per # beam pulse; when COLL:LI18:960 (CX1896) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "COLL:LI18:960:MASK") { field(DESC, "CX1896 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(TSE, "-1") } # # This record takes the calibration offset from # COLL:LI18:960 (CX1896) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "COLL:LI18:960:NEWOFFS") { field(DESC, "New CX1896 Cal") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:960:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:960:POSN.EOFF") } record(ao, "COLL:LI18:960:MOTRVAL") { field(DESC, "CX1896 Value Proxy") field(EGU, "mm") field(OMSL, "supervisory") field(DRVH, "10.00") field(DRVL, "-55.00") field(SCAN, "Passive") field(OUT, "COLL:LI18:960:MOTR.VAL") field(FLNK, "COLL:LI18:960:MOTR") } record(ao, "COLL:LI18:960:MOTRHI") { field(DESC, "Move CX1896 High") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:960:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:960:MOTR.VAL") field(FLNK, "COLL:LI18:960:MOTR") } record(ao, "COLL:LI18:960:MOTRLO") { field(DESC, "Move CX1896 Low") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:960:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:960:MOTR.VAL") field(FLNK, "COLL:LI18:960:MOTR") } record(mbbo, "COLL:LI18:960:MOTRVELCHOICE") { field(DESC, "CX1896 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "COLL:LI18:960:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "5") field(ONST, "Maximum") field(ONVL, "8") field(TWST, "Medium") field(TWVL, "5") field(THST, "Slow") field(THVL, "3") } record(fanout, "COLL:LI18:960:SYNCMOTPROFILE") { field(DESC, "CX1896 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "COLL:LI18:960:MOTPROFILE") field(LNK2, "COLL:LI18:960:LVDTPROFILE") field(LNK3, "COLL:LI18:960:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "COLL:LI18:960:CALIBSYNC") { field(DESC, "CX1896 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "COLL:LI18:960:MOTPROFILE") { field(DESC, "CX1896 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:960:POSN PP") } record(compress, "COLL:LI18:960:LVDTPROFILE") { field(DESC, "CX1896 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:960:LVRAW PP") } record(subArray, "COLL:LI18:960:SUBLPROF") { field(DESC, "CX1896 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:960:PLVDTPROFILE.VAL") } record(subArray, "COLL:LI18:960:SUBMPROF") { field(DESC, "CX1896 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:960:PMOTPROFILE.VAL") } record(waveform, "COLL:LI18:960:PMOTPROFILE") { field(DESC, "CX1896 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:960:MOTPROFILE") field(FLNK, "COLL:LI18:960:SUBMPROF") } record(waveform, "COLL:LI18:960:PLVDTPROFILE") { field(DESC, "CX1896 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:960:LVDTPROFILE") field(FLNK, "COLL:LI18:960:SUBLPROF") } record(ai, "COLL:LI18:960:MOTRVALREST") { field(INP, "COLL:LI18:960:MOTR") } #! Further lines contain data used by VisualDCT #! View(149,96,0.7) #! Record("COLL:LI18:960:MOTR",340,130,0,0,"COLL:LI18:960:MOTR") #! Field("COLL:LI18:960:MOTR.OFF",16777215,1,"COLL:LI18:960:MOTR.OFF") #! Field("COLL:LI18:960:MOTR.VAL",16777215,1,"COLL:LI18:960:MOTR.VAL") #! Field("COLL:LI18:960:MOTR.HLM",16777215,1,"COLL:LI18:960:MOTR.HLM") #! Field("COLL:LI18:960:MOTR.LLM",16777215,1,"COLL:LI18:960:MOTR.LLM") #! Field("COLL:LI18:960:MOTR.VELO",16777215,1,"COLL:LI18:960:MOTR.VELO") #! Field("COLL:LI18:960:MOTR.RDBL",16777215,1,"COLL:LI18:960:MOTR.RDBL") #! Field("COLL:LI18:960:MOTR.FLNK",16777215,1,"COLL:LI18:960:MOTR.FLNK") #! Link("COLL:LI18:960:MOTR.FLNK","COLL:LI18:960:MOTRVALREST") #! Record("COLL:LI18:960:POSN",1060,842,0,0,"COLL:LI18:960:POSN") #! Field("COLL:LI18:960:POSN.EOFF",16777215,1,"COLL:LI18:960:POSN.EOFF") #! Field("COLL:LI18:960:POSN.VAL",16777215,1,"COLL:LI18:960:POSN.VAL") #! Record("COLL:LI18:960:MASK",2440,273,0,0,"COLL:LI18:960:MASK") #! Record("COLL:LI18:960:NEWOFFS",820,919,0,0,"COLL:LI18:960:NEWOFFS") #! Field("COLL:LI18:960:NEWOFFS.DOL",16777215,0,"COLL:LI18:960:NEWOFFS.DOL") #! Link("COLL:LI18:960:NEWOFFS.DOL","COLL:LI18:960:MOTR.OFF") #! Field("COLL:LI18:960:NEWOFFS.OUT",16777215,1,"COLL:LI18:960:NEWOFFS.OUT") #! Link("COLL:LI18:960:NEWOFFS.OUT","COLL:LI18:960:POSN.EOFF") #! Record("COLL:LI18:960:MOTRVAL",760,1893,0,0,"COLL:LI18:960:MOTRVAL") #! Field("COLL:LI18:960:MOTRVAL.OUT",16777215,0,"COLL:LI18:960:MOTRVAL.OUT") #! Link("COLL:LI18:960:MOTRVAL.OUT","COLL:LI18:960:MOTR.VAL") #! Field("COLL:LI18:960:MOTRVAL.FLNK",16777215,0,"COLL:LI18:960:MOTRVAL.FLNK") #! Link("COLL:LI18:960:MOTRVAL.FLNK","COLL:LI18:960:MOTR") #! Record("COLL:LI18:960:MOTRHI",740,2685,0,0,"COLL:LI18:960:MOTRHI") #! Field("COLL:LI18:960:MOTRHI.DOL",16777215,0,"COLL:LI18:960:MOTRHI.DOL") #! Link("COLL:LI18:960:MOTRHI.DOL","COLL:LI18:960:MOTR.HLM") #! Field("COLL:LI18:960:MOTRHI.OUT",16777215,0,"COLL:LI18:960:MOTRHI.OUT") #! Link("COLL:LI18:960:MOTRHI.OUT","COLL:LI18:960:MOTR.VAL") #! Field("COLL:LI18:960:MOTRHI.FLNK",16777215,0,"COLL:LI18:960:MOTRHI.FLNK") #! Link("COLL:LI18:960:MOTRHI.FLNK","COLL:LI18:960:MOTR") #! Record("COLL:LI18:960:MOTRLO",720,2265,0,0,"COLL:LI18:960:MOTRLO") #! Field("COLL:LI18:960:MOTRLO.DOL",16777215,0,"COLL:LI18:960:MOTRLO.DOL") #! Link("COLL:LI18:960:MOTRLO.DOL","COLL:LI18:960:MOTR.LLM") #! Field("COLL:LI18:960:MOTRLO.OUT",16777215,0,"COLL:LI18:960:MOTRLO.OUT") #! Link("COLL:LI18:960:MOTRLO.OUT","COLL:LI18:960:MOTR.VAL") #! Field("COLL:LI18:960:MOTRLO.FLNK",16777215,0,"COLL:LI18:960:MOTRLO.FLNK") #! Link("COLL:LI18:960:MOTRLO.FLNK","COLL:LI18:960:MOTR") #! Record("COLL:LI18:960:MOTRVELCHOICE",740,1428,0,0,"COLL:LI18:960:MOTRVELCHOICE") #! Field("COLL:LI18:960:MOTRVELCHOICE.OUT",16777215,0,"COLL:LI18:960:MOTRVELCHOICE.OUT") #! Link("COLL:LI18:960:MOTRVELCHOICE.OUT","COLL:LI18:960:MOTR.VELO") #! Record("COLL:LI18:960:SYNCMOTPROFILE",640,128,0,0,"COLL:LI18:960:SYNCMOTPROFILE") #! Field("COLL:LI18:960:SYNCMOTPROFILE.LNK3",16777215,1,"COLL:LI18:960:SYNCMOTPROFILE.LNK3") #! Link("COLL:LI18:960:SYNCMOTPROFILE.LNK3","COLL:LI18:960:CALIBSYNC") #! Field("COLL:LI18:960:SYNCMOTPROFILE.LNK2",16777215,1,"COLL:LI18:960:SYNCMOTPROFILE.LNK2") #! Link("COLL:LI18:960:SYNCMOTPROFILE.LNK2","COLL:LI18:960:LVDTPROFILE") #! Field("COLL:LI18:960:SYNCMOTPROFILE.LNK1",16777215,1,"COLL:LI18:960:SYNCMOTPROFILE.LNK1") #! Link("COLL:LI18:960:SYNCMOTPROFILE.LNK1","COLL:LI18:960:MOTPROFILE") #! Record("COLL:LI18:960:CALIBSYNC",1440,72,0,0,"COLL:LI18:960:CALIBSYNC") #! Record("COLL:LI18:960:MOTPROFILE",1380,838,0,0,"COLL:LI18:960:MOTPROFILE") #! Field("COLL:LI18:960:MOTPROFILE.VAL",16777215,1,"COLL:LI18:960:MOTPROFILE.VAL") #! Field("COLL:LI18:960:MOTPROFILE.INP",16777215,0,"COLL:LI18:960:MOTPROFILE.INP") #! Link("COLL:LI18:960:MOTPROFILE.INP","COLL:LI18:960:POSN.VAL") #! Record("COLL:LI18:960:LVDTPROFILE",1460,258,0,0,"COLL:LI18:960:LVDTPROFILE") #! Field("COLL:LI18:960:LVDTPROFILE.INP",16777215,1,"COLL:LI18:960:LVDTPROFILE.INP") #! Field("COLL:LI18:960:LVDTPROFILE.VAL",16777215,1,"COLL:LI18:960:LVDTPROFILE.VAL") #! Record("COLL:LI18:960:SUBLPROF",2140,288,0,0,"COLL:LI18:960:SUBLPROF") #! Field("COLL:LI18:960:SUBLPROF.INP",16777215,0,"COLL:LI18:960:SUBLPROF.INP") #! Link("COLL:LI18:960:SUBLPROF.INP","COLL:LI18:960:PLVDTPROFILE.VAL") #! Record("COLL:LI18:960:SUBMPROF",2260,908,0,0,"COLL:LI18:960:SUBMPROF") #! Field("COLL:LI18:960:SUBMPROF.INP",16777215,0,"COLL:LI18:960:SUBMPROF.INP") #! Link("COLL:LI18:960:SUBMPROF.INP","COLL:LI18:960:PMOTPROFILE.VAL") #! Record("COLL:LI18:960:PMOTPROFILE",1660,808,0,0,"COLL:LI18:960:PMOTPROFILE") #! Field("COLL:LI18:960:PMOTPROFILE.INP",16777215,0,"COLL:LI18:960:PMOTPROFILE.INP") #! Link("COLL:LI18:960:PMOTPROFILE.INP","COLL:LI18:960:MOTPROFILE.VAL") #! Field("COLL:LI18:960:PMOTPROFILE.VAL",16777215,1,"COLL:LI18:960:PMOTPROFILE.VAL") #! Field("COLL:LI18:960:PMOTPROFILE.FLNK",16777215,1,"COLL:LI18:960:PMOTPROFILE.FLNK") #! Link("COLL:LI18:960:PMOTPROFILE.FLNK","COLL:LI18:960:SUBMPROF") #! Record("COLL:LI18:960:PLVDTPROFILE",1800,248,0,0,"COLL:LI18:960:PLVDTPROFILE") #! Field("COLL:LI18:960:PLVDTPROFILE.INP",16777215,0,"COLL:LI18:960:PLVDTPROFILE.INP") #! Link("COLL:LI18:960:PLVDTPROFILE.INP","COLL:LI18:960:LVDTPROFILE.VAL") #! Field("COLL:LI18:960:PLVDTPROFILE.FLNK",16777215,1,"COLL:LI18:960:PLVDTPROFILE.FLNK") #! Link("COLL:LI18:960:PLVDTPROFILE.FLNK","COLL:LI18:960:SUBLPROF") #! Field("COLL:LI18:960:PLVDTPROFILE.VAL",16777215,1,"COLL:LI18:960:PLVDTPROFILE.VAL") #! Record("COLL:LI18:960:MOTRVALREST",800,709,0,0,"COLL:LI18:960:MOTRVALREST") #! Field("COLL:LI18:960:MOTRVALREST.INP",16777215,0,"COLL:LI18:960:MOTRVALREST.INP") #! Link("COLL:LI18:960:MOTRVALREST.INP","COLL:LI18:960:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-02/2 record(motor, "COLL:LI18:963:MOTR") { field(DESC, "CY1896 Coll Top Jaw Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "8") field(VBAS, "2") field(VMAX, "8") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-02, 2)") field(MRES, "0.005") field(SREV, "400") field(PREC, "4") field(EGU, "mm") field(DHLM, "10.00") field(HOPR, "10.00") field(DLLM, "-55.00") field(LOPR, "-55.00") field(DLY, "0") field(TWV, "1.0") field(SET, "1") field(RDBD, "0.2") field(FOFF, "Frozen") field(FLNK, "COLL:LI18:963:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "2") field(BACC, "0.5") field(RDBL, "COLL:LI18:963:LVPOS") info(autosaveFields, "DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV HLM LLM") } # Position of motor on COLL:LI18:963 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "COLL:LI18:963:POSN") { field(DESC, "CY1896 Current Position") field(DTYP, "asynInt32") field(EGU, "mm") field(INP, "@asyn(Hy8601-02 2)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.005") field(PREC, "4") field(TSE, "-1") } # # This record contains a simple value that changes per # beam pulse; when COLL:LI18:963 (CY1896) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "COLL:LI18:963:MASK") { field(DESC, "CY1896 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(TSE, "-1") } # # This record takes the calibration offset from # COLL:LI18:963 (CY1896) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "COLL:LI18:963:NEWOFFS") { field(DESC, "New CY1896 Cal") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:963:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:963:POSN.EOFF") } record(ao, "COLL:LI18:963:MOTRVAL") { field(DESC, "CY1896 Value Proxy") field(EGU, "mm") field(OMSL, "supervisory") field(DRVH, "10.00") field(DRVL, "-55.00") field(SCAN, "Passive") field(OUT, "COLL:LI18:963:MOTR.VAL") field(FLNK, "COLL:LI18:963:MOTR") } record(ao, "COLL:LI18:963:MOTRHI") { field(DESC, "Move CY1896 High") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:963:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:963:MOTR.VAL") field(FLNK, "COLL:LI18:963:MOTR") } record(ao, "COLL:LI18:963:MOTRLO") { field(DESC, "Move CY1896 Low") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:963:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:963:MOTR.VAL") field(FLNK, "COLL:LI18:963:MOTR") } record(mbbo, "COLL:LI18:963:MOTRVELCHOICE") { field(DESC, "CY1896 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "COLL:LI18:963:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "5") field(ONST, "Maximum") field(ONVL, "8") field(TWST, "Medium") field(TWVL, "5") field(THST, "Slow") field(THVL, "3") } record(fanout, "COLL:LI18:963:SYNCMOTPROFILE") { field(DESC, "CY1896 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "COLL:LI18:963:MOTPROFILE") field(LNK2, "COLL:LI18:963:LVDTPROFILE") field(LNK3, "COLL:LI18:963:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "COLL:LI18:963:CALIBSYNC") { field(DESC, "CY1896 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "COLL:LI18:963:MOTPROFILE") { field(DESC, "CY1896 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:963:POSN PP") } record(compress, "COLL:LI18:963:LVDTPROFILE") { field(DESC, "CY1896 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:963:LVRAW PP") } record(subArray, "COLL:LI18:963:SUBLPROF") { field(DESC, "CY1896 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:963:PLVDTPROFILE.VAL") } record(subArray, "COLL:LI18:963:SUBMPROF") { field(DESC, "CY1896 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:963:PMOTPROFILE.VAL") } record(waveform, "COLL:LI18:963:PMOTPROFILE") { field(DESC, "CY1896 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:963:MOTPROFILE") field(FLNK, "COLL:LI18:963:SUBMPROF") } record(waveform, "COLL:LI18:963:PLVDTPROFILE") { field(DESC, "CY1896 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:963:LVDTPROFILE") field(FLNK, "COLL:LI18:963:SUBLPROF") } record(ai, "COLL:LI18:963:MOTRVALREST") { field(INP, "COLL:LI18:963:MOTR") } #! Further lines contain data used by VisualDCT #! View(149,96,0.7) #! Record("COLL:LI18:963:MOTR",340,130,0,0,"COLL:LI18:963:MOTR") #! Field("COLL:LI18:963:MOTR.OFF",16777215,1,"COLL:LI18:963:MOTR.OFF") #! Field("COLL:LI18:963:MOTR.VAL",16777215,1,"COLL:LI18:963:MOTR.VAL") #! Field("COLL:LI18:963:MOTR.HLM",16777215,1,"COLL:LI18:963:MOTR.HLM") #! Field("COLL:LI18:963:MOTR.LLM",16777215,1,"COLL:LI18:963:MOTR.LLM") #! Field("COLL:LI18:963:MOTR.VELO",16777215,1,"COLL:LI18:963:MOTR.VELO") #! Field("COLL:LI18:963:MOTR.RDBL",16777215,1,"COLL:LI18:963:MOTR.RDBL") #! Field("COLL:LI18:963:MOTR.FLNK",16777215,1,"COLL:LI18:963:MOTR.FLNK") #! Link("COLL:LI18:963:MOTR.FLNK","COLL:LI18:963:MOTRVALREST") #! Record("COLL:LI18:963:POSN",1060,842,0,0,"COLL:LI18:963:POSN") #! Field("COLL:LI18:963:POSN.EOFF",16777215,1,"COLL:LI18:963:POSN.EOFF") #! Field("COLL:LI18:963:POSN.VAL",16777215,1,"COLL:LI18:963:POSN.VAL") #! Record("COLL:LI18:963:MASK",2440,273,0,0,"COLL:LI18:963:MASK") #! Record("COLL:LI18:963:NEWOFFS",820,919,0,0,"COLL:LI18:963:NEWOFFS") #! Field("COLL:LI18:963:NEWOFFS.DOL",16777215,0,"COLL:LI18:963:NEWOFFS.DOL") #! Link("COLL:LI18:963:NEWOFFS.DOL","COLL:LI18:963:MOTR.OFF") #! Field("COLL:LI18:963:NEWOFFS.OUT",16777215,1,"COLL:LI18:963:NEWOFFS.OUT") #! Link("COLL:LI18:963:NEWOFFS.OUT","COLL:LI18:963:POSN.EOFF") #! Record("COLL:LI18:963:MOTRVAL",760,1893,0,0,"COLL:LI18:963:MOTRVAL") #! Field("COLL:LI18:963:MOTRVAL.OUT",16777215,0,"COLL:LI18:963:MOTRVAL.OUT") #! Link("COLL:LI18:963:MOTRVAL.OUT","COLL:LI18:963:MOTR.VAL") #! Field("COLL:LI18:963:MOTRVAL.FLNK",16777215,0,"COLL:LI18:963:MOTRVAL.FLNK") #! Link("COLL:LI18:963:MOTRVAL.FLNK","COLL:LI18:963:MOTR") #! Record("COLL:LI18:963:MOTRHI",740,2685,0,0,"COLL:LI18:963:MOTRHI") #! Field("COLL:LI18:963:MOTRHI.DOL",16777215,0,"COLL:LI18:963:MOTRHI.DOL") #! Link("COLL:LI18:963:MOTRHI.DOL","COLL:LI18:963:MOTR.HLM") #! Field("COLL:LI18:963:MOTRHI.OUT",16777215,0,"COLL:LI18:963:MOTRHI.OUT") #! Link("COLL:LI18:963:MOTRHI.OUT","COLL:LI18:963:MOTR.VAL") #! Field("COLL:LI18:963:MOTRHI.FLNK",16777215,0,"COLL:LI18:963:MOTRHI.FLNK") #! Link("COLL:LI18:963:MOTRHI.FLNK","COLL:LI18:963:MOTR") #! Record("COLL:LI18:963:MOTRLO",720,2265,0,0,"COLL:LI18:963:MOTRLO") #! Field("COLL:LI18:963:MOTRLO.DOL",16777215,0,"COLL:LI18:963:MOTRLO.DOL") #! Link("COLL:LI18:963:MOTRLO.DOL","COLL:LI18:963:MOTR.LLM") #! Field("COLL:LI18:963:MOTRLO.OUT",16777215,0,"COLL:LI18:963:MOTRLO.OUT") #! Link("COLL:LI18:963:MOTRLO.OUT","COLL:LI18:963:MOTR.VAL") #! Field("COLL:LI18:963:MOTRLO.FLNK",16777215,0,"COLL:LI18:963:MOTRLO.FLNK") #! Link("COLL:LI18:963:MOTRLO.FLNK","COLL:LI18:963:MOTR") #! Record("COLL:LI18:963:MOTRVELCHOICE",740,1428,0,0,"COLL:LI18:963:MOTRVELCHOICE") #! Field("COLL:LI18:963:MOTRVELCHOICE.OUT",16777215,0,"COLL:LI18:963:MOTRVELCHOICE.OUT") #! Link("COLL:LI18:963:MOTRVELCHOICE.OUT","COLL:LI18:963:MOTR.VELO") #! Record("COLL:LI18:963:SYNCMOTPROFILE",640,128,0,0,"COLL:LI18:963:SYNCMOTPROFILE") #! Field("COLL:LI18:963:SYNCMOTPROFILE.LNK3",16777215,1,"COLL:LI18:963:SYNCMOTPROFILE.LNK3") #! Link("COLL:LI18:963:SYNCMOTPROFILE.LNK3","COLL:LI18:963:CALIBSYNC") #! Field("COLL:LI18:963:SYNCMOTPROFILE.LNK2",16777215,1,"COLL:LI18:963:SYNCMOTPROFILE.LNK2") #! Link("COLL:LI18:963:SYNCMOTPROFILE.LNK2","COLL:LI18:963:LVDTPROFILE") #! Field("COLL:LI18:963:SYNCMOTPROFILE.LNK1",16777215,1,"COLL:LI18:963:SYNCMOTPROFILE.LNK1") #! Link("COLL:LI18:963:SYNCMOTPROFILE.LNK1","COLL:LI18:963:MOTPROFILE") #! Record("COLL:LI18:963:CALIBSYNC",1440,72,0,0,"COLL:LI18:963:CALIBSYNC") #! Record("COLL:LI18:963:MOTPROFILE",1380,838,0,0,"COLL:LI18:963:MOTPROFILE") #! Field("COLL:LI18:963:MOTPROFILE.VAL",16777215,1,"COLL:LI18:963:MOTPROFILE.VAL") #! Field("COLL:LI18:963:MOTPROFILE.INP",16777215,0,"COLL:LI18:963:MOTPROFILE.INP") #! Link("COLL:LI18:963:MOTPROFILE.INP","COLL:LI18:963:POSN.VAL") #! Record("COLL:LI18:963:LVDTPROFILE",1460,258,0,0,"COLL:LI18:963:LVDTPROFILE") #! Field("COLL:LI18:963:LVDTPROFILE.INP",16777215,1,"COLL:LI18:963:LVDTPROFILE.INP") #! Field("COLL:LI18:963:LVDTPROFILE.VAL",16777215,1,"COLL:LI18:963:LVDTPROFILE.VAL") #! Record("COLL:LI18:963:SUBLPROF",2140,288,0,0,"COLL:LI18:963:SUBLPROF") #! Field("COLL:LI18:963:SUBLPROF.INP",16777215,0,"COLL:LI18:963:SUBLPROF.INP") #! Link("COLL:LI18:963:SUBLPROF.INP","COLL:LI18:963:PLVDTPROFILE.VAL") #! Record("COLL:LI18:963:SUBMPROF",2260,908,0,0,"COLL:LI18:963:SUBMPROF") #! Field("COLL:LI18:963:SUBMPROF.INP",16777215,0,"COLL:LI18:963:SUBMPROF.INP") #! Link("COLL:LI18:963:SUBMPROF.INP","COLL:LI18:963:PMOTPROFILE.VAL") #! Record("COLL:LI18:963:PMOTPROFILE",1660,808,0,0,"COLL:LI18:963:PMOTPROFILE") #! Field("COLL:LI18:963:PMOTPROFILE.INP",16777215,0,"COLL:LI18:963:PMOTPROFILE.INP") #! Link("COLL:LI18:963:PMOTPROFILE.INP","COLL:LI18:963:MOTPROFILE.VAL") #! Field("COLL:LI18:963:PMOTPROFILE.VAL",16777215,1,"COLL:LI18:963:PMOTPROFILE.VAL") #! Field("COLL:LI18:963:PMOTPROFILE.FLNK",16777215,1,"COLL:LI18:963:PMOTPROFILE.FLNK") #! Link("COLL:LI18:963:PMOTPROFILE.FLNK","COLL:LI18:963:SUBMPROF") #! Record("COLL:LI18:963:PLVDTPROFILE",1800,248,0,0,"COLL:LI18:963:PLVDTPROFILE") #! Field("COLL:LI18:963:PLVDTPROFILE.INP",16777215,0,"COLL:LI18:963:PLVDTPROFILE.INP") #! Link("COLL:LI18:963:PLVDTPROFILE.INP","COLL:LI18:963:LVDTPROFILE.VAL") #! Field("COLL:LI18:963:PLVDTPROFILE.FLNK",16777215,1,"COLL:LI18:963:PLVDTPROFILE.FLNK") #! Link("COLL:LI18:963:PLVDTPROFILE.FLNK","COLL:LI18:963:SUBLPROF") #! Field("COLL:LI18:963:PLVDTPROFILE.VAL",16777215,1,"COLL:LI18:963:PLVDTPROFILE.VAL") #! Record("COLL:LI18:963:MOTRVALREST",800,709,0,0,"COLL:LI18:963:MOTRVALREST") #! Field("COLL:LI18:963:MOTRVALREST.INP",16777215,0,"COLL:LI18:963:MOTRVALREST.INP") #! Link("COLL:LI18:963:MOTRVALREST.INP","COLL:LI18:963:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-02/3 record(motor, "COLL:LI18:962:MOTR") { field(DESC, "CY1896 Coll Bottom Jaw Motion") field(SCAN, "Passive") field(DIR, "Neg") field(DTYP, "asynMotor") field(VELO, "8") field(VBAS, "2") field(VMAX, "8") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-02, 3)") field(MRES, "0.005") field(SREV, "400") field(PREC, "4") field(EGU, "mm") field(DHLM, "10.00") field(HOPR, "10.00") field(DLLM, "-55.00") field(LOPR, "-55.00") field(DLY, "0") field(TWV, "1.0") field(SET, "1") field(RDBD, "0.2") field(FOFF, "Frozen") field(FLNK, "COLL:LI18:962:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "2") field(BACC, "0.5") field(RDBL, "COLL:LI18:962:LVPOS") info(autosaveFields, "DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV HLM LLM") } # Position of motor on COLL:LI18:962 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "COLL:LI18:962:POSN") { field(DESC, "CY1896 Current Position") field(DTYP, "asynInt32") field(EGU, "mm") field(INP, "@asyn(Hy8601-02 3)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "-0.005") field(PREC, "4") field(TSE, "-1") } # # This record contains a simple value that changes per # beam pulse; when COLL:LI18:962 (CY1896) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "COLL:LI18:962:MASK") { field(DESC, "CY1896 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(TSE, "-1") } # # This record takes the calibration offset from # COLL:LI18:962 (CY1896) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "COLL:LI18:962:NEWOFFS") { field(DESC, "New CY1896 Cal") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:962:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:962:POSN.EOFF") } record(ao, "COLL:LI18:962:MOTRVAL") { field(DESC, "CY1896 Value Proxy") field(EGU, "mm") field(OMSL, "supervisory") field(DRVH, "10.00") field(DRVL, "-55.00") field(SCAN, "Passive") field(OUT, "COLL:LI18:962:MOTR.VAL") field(FLNK, "COLL:LI18:962:MOTR") } record(ao, "COLL:LI18:962:MOTRHI") { field(DESC, "Move CY1896 High") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:962:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:962:MOTR.VAL") field(FLNK, "COLL:LI18:962:MOTR") } record(ao, "COLL:LI18:962:MOTRLO") { field(DESC, "Move CY1896 Low") field(EGU, "mm") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "COLL:LI18:962:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "COLL:LI18:962:MOTR.VAL") field(FLNK, "COLL:LI18:962:MOTR") } record(mbbo, "COLL:LI18:962:MOTRVELCHOICE") { field(DESC, "CY1896 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "COLL:LI18:962:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "5") field(ONST, "Maximum") field(ONVL, "8") field(TWST, "Medium") field(TWVL, "5") field(THST, "Slow") field(THVL, "3") } record(fanout, "COLL:LI18:962:SYNCMOTPROFILE") { field(DESC, "CY1896 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "COLL:LI18:962:MOTPROFILE") field(LNK2, "COLL:LI18:962:LVDTPROFILE") field(LNK3, "COLL:LI18:962:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "COLL:LI18:962:CALIBSYNC") { field(DESC, "CY1896 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "COLL:LI18:962:MOTPROFILE") { field(DESC, "CY1896 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:962:POSN PP") } record(compress, "COLL:LI18:962:LVDTPROFILE") { field(DESC, "CY1896 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "COLL:LI18:962:LVRAW PP") } record(subArray, "COLL:LI18:962:SUBLPROF") { field(DESC, "CY1896 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:962:PLVDTPROFILE.VAL") } record(subArray, "COLL:LI18:962:SUBMPROF") { field(DESC, "CY1896 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "COLL:LI18:962:PMOTPROFILE.VAL") } record(waveform, "COLL:LI18:962:PMOTPROFILE") { field(DESC, "CY1896 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:962:MOTPROFILE") field(FLNK, "COLL:LI18:962:SUBMPROF") } record(waveform, "COLL:LI18:962:PLVDTPROFILE") { field(DESC, "CY1896 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "mm") field(NELM, "200") field(INP, "COLL:LI18:962:LVDTPROFILE") field(FLNK, "COLL:LI18:962:SUBLPROF") } record(ai, "COLL:LI18:962:MOTRVALREST") { field(INP, "COLL:LI18:962:MOTR") } #! Further lines contain data used by VisualDCT #! View(149,96,0.7) #! Record("COLL:LI18:962:MOTR",340,130,0,0,"COLL:LI18:962:MOTR") #! Field("COLL:LI18:962:MOTR.OFF",16777215,1,"COLL:LI18:962:MOTR.OFF") #! Field("COLL:LI18:962:MOTR.VAL",16777215,1,"COLL:LI18:962:MOTR.VAL") #! Field("COLL:LI18:962:MOTR.HLM",16777215,1,"COLL:LI18:962:MOTR.HLM") #! Field("COLL:LI18:962:MOTR.LLM",16777215,1,"COLL:LI18:962:MOTR.LLM") #! Field("COLL:LI18:962:MOTR.VELO",16777215,1,"COLL:LI18:962:MOTR.VELO") #! Field("COLL:LI18:962:MOTR.RDBL",16777215,1,"COLL:LI18:962:MOTR.RDBL") #! Field("COLL:LI18:962:MOTR.FLNK",16777215,1,"COLL:LI18:962:MOTR.FLNK") #! Link("COLL:LI18:962:MOTR.FLNK","COLL:LI18:962:MOTRVALREST") #! Record("COLL:LI18:962:POSN",1060,842,0,0,"COLL:LI18:962:POSN") #! Field("COLL:LI18:962:POSN.EOFF",16777215,1,"COLL:LI18:962:POSN.EOFF") #! Field("COLL:LI18:962:POSN.VAL",16777215,1,"COLL:LI18:962:POSN.VAL") #! Record("COLL:LI18:962:MASK",2440,273,0,0,"COLL:LI18:962:MASK") #! Record("COLL:LI18:962:NEWOFFS",820,919,0,0,"COLL:LI18:962:NEWOFFS") #! Field("COLL:LI18:962:NEWOFFS.DOL",16777215,0,"COLL:LI18:962:NEWOFFS.DOL") #! Link("COLL:LI18:962:NEWOFFS.DOL","COLL:LI18:962:MOTR.OFF") #! Field("COLL:LI18:962:NEWOFFS.OUT",16777215,1,"COLL:LI18:962:NEWOFFS.OUT") #! Link("COLL:LI18:962:NEWOFFS.OUT","COLL:LI18:962:POSN.EOFF") #! Record("COLL:LI18:962:MOTRVAL",760,1893,0,0,"COLL:LI18:962:MOTRVAL") #! Field("COLL:LI18:962:MOTRVAL.OUT",16777215,0,"COLL:LI18:962:MOTRVAL.OUT") #! Link("COLL:LI18:962:MOTRVAL.OUT","COLL:LI18:962:MOTR.VAL") #! Field("COLL:LI18:962:MOTRVAL.FLNK",16777215,0,"COLL:LI18:962:MOTRVAL.FLNK") #! Link("COLL:LI18:962:MOTRVAL.FLNK","COLL:LI18:962:MOTR") #! Record("COLL:LI18:962:MOTRHI",740,2685,0,0,"COLL:LI18:962:MOTRHI") #! Field("COLL:LI18:962:MOTRHI.DOL",16777215,0,"COLL:LI18:962:MOTRHI.DOL") #! Link("COLL:LI18:962:MOTRHI.DOL","COLL:LI18:962:MOTR.HLM") #! Field("COLL:LI18:962:MOTRHI.OUT",16777215,0,"COLL:LI18:962:MOTRHI.OUT") #! Link("COLL:LI18:962:MOTRHI.OUT","COLL:LI18:962:MOTR.VAL") #! Field("COLL:LI18:962:MOTRHI.FLNK",16777215,0,"COLL:LI18:962:MOTRHI.FLNK") #! Link("COLL:LI18:962:MOTRHI.FLNK","COLL:LI18:962:MOTR") #! Record("COLL:LI18:962:MOTRLO",720,2265,0,0,"COLL:LI18:962:MOTRLO") #! Field("COLL:LI18:962:MOTRLO.DOL",16777215,0,"COLL:LI18:962:MOTRLO.DOL") #! Link("COLL:LI18:962:MOTRLO.DOL","COLL:LI18:962:MOTR.LLM") #! Field("COLL:LI18:962:MOTRLO.OUT",16777215,0,"COLL:LI18:962:MOTRLO.OUT") #! Link("COLL:LI18:962:MOTRLO.OUT","COLL:LI18:962:MOTR.VAL") #! Field("COLL:LI18:962:MOTRLO.FLNK",16777215,0,"COLL:LI18:962:MOTRLO.FLNK") #! Link("COLL:LI18:962:MOTRLO.FLNK","COLL:LI18:962:MOTR") #! Record("COLL:LI18:962:MOTRVELCHOICE",740,1428,0,0,"COLL:LI18:962:MOTRVELCHOICE") #! Field("COLL:LI18:962:MOTRVELCHOICE.OUT",16777215,0,"COLL:LI18:962:MOTRVELCHOICE.OUT") #! Link("COLL:LI18:962:MOTRVELCHOICE.OUT","COLL:LI18:962:MOTR.VELO") #! Record("COLL:LI18:962:SYNCMOTPROFILE",640,128,0,0,"COLL:LI18:962:SYNCMOTPROFILE") #! Field("COLL:LI18:962:SYNCMOTPROFILE.LNK3",16777215,1,"COLL:LI18:962:SYNCMOTPROFILE.LNK3") #! Link("COLL:LI18:962:SYNCMOTPROFILE.LNK3","COLL:LI18:962:CALIBSYNC") #! Field("COLL:LI18:962:SYNCMOTPROFILE.LNK2",16777215,1,"COLL:LI18:962:SYNCMOTPROFILE.LNK2") #! Link("COLL:LI18:962:SYNCMOTPROFILE.LNK2","COLL:LI18:962:LVDTPROFILE") #! Field("COLL:LI18:962:SYNCMOTPROFILE.LNK1",16777215,1,"COLL:LI18:962:SYNCMOTPROFILE.LNK1") #! Link("COLL:LI18:962:SYNCMOTPROFILE.LNK1","COLL:LI18:962:MOTPROFILE") #! Record("COLL:LI18:962:CALIBSYNC",1440,72,0,0,"COLL:LI18:962:CALIBSYNC") #! Record("COLL:LI18:962:MOTPROFILE",1380,838,0,0,"COLL:LI18:962:MOTPROFILE") #! Field("COLL:LI18:962:MOTPROFILE.VAL",16777215,1,"COLL:LI18:962:MOTPROFILE.VAL") #! Field("COLL:LI18:962:MOTPROFILE.INP",16777215,0,"COLL:LI18:962:MOTPROFILE.INP") #! Link("COLL:LI18:962:MOTPROFILE.INP","COLL:LI18:962:POSN.VAL") #! Record("COLL:LI18:962:LVDTPROFILE",1460,258,0,0,"COLL:LI18:962:LVDTPROFILE") #! Field("COLL:LI18:962:LVDTPROFILE.INP",16777215,1,"COLL:LI18:962:LVDTPROFILE.INP") #! Field("COLL:LI18:962:LVDTPROFILE.VAL",16777215,1,"COLL:LI18:962:LVDTPROFILE.VAL") #! Record("COLL:LI18:962:SUBLPROF",2140,288,0,0,"COLL:LI18:962:SUBLPROF") #! Field("COLL:LI18:962:SUBLPROF.INP",16777215,0,"COLL:LI18:962:SUBLPROF.INP") #! Link("COLL:LI18:962:SUBLPROF.INP","COLL:LI18:962:PLVDTPROFILE.VAL") #! Record("COLL:LI18:962:SUBMPROF",2260,908,0,0,"COLL:LI18:962:SUBMPROF") #! Field("COLL:LI18:962:SUBMPROF.INP",16777215,0,"COLL:LI18:962:SUBMPROF.INP") #! Link("COLL:LI18:962:SUBMPROF.INP","COLL:LI18:962:PMOTPROFILE.VAL") #! Record("COLL:LI18:962:PMOTPROFILE",1660,808,0,0,"COLL:LI18:962:PMOTPROFILE") #! Field("COLL:LI18:962:PMOTPROFILE.INP",16777215,0,"COLL:LI18:962:PMOTPROFILE.INP") #! Link("COLL:LI18:962:PMOTPROFILE.INP","COLL:LI18:962:MOTPROFILE.VAL") #! Field("COLL:LI18:962:PMOTPROFILE.VAL",16777215,1,"COLL:LI18:962:PMOTPROFILE.VAL") #! Field("COLL:LI18:962:PMOTPROFILE.FLNK",16777215,1,"COLL:LI18:962:PMOTPROFILE.FLNK") #! Link("COLL:LI18:962:PMOTPROFILE.FLNK","COLL:LI18:962:SUBMPROF") #! Record("COLL:LI18:962:PLVDTPROFILE",1800,248,0,0,"COLL:LI18:962:PLVDTPROFILE") #! Field("COLL:LI18:962:PLVDTPROFILE.INP",16777215,0,"COLL:LI18:962:PLVDTPROFILE.INP") #! Link("COLL:LI18:962:PLVDTPROFILE.INP","COLL:LI18:962:LVDTPROFILE.VAL") #! Field("COLL:LI18:962:PLVDTPROFILE.FLNK",16777215,1,"COLL:LI18:962:PLVDTPROFILE.FLNK") #! Link("COLL:LI18:962:PLVDTPROFILE.FLNK","COLL:LI18:962:SUBLPROF") #! Field("COLL:LI18:962:PLVDTPROFILE.VAL",16777215,1,"COLL:LI18:962:PLVDTPROFILE.VAL") #! Record("COLL:LI18:962:MOTRVALREST",800,709,0,0,"COLL:LI18:962:MOTRVALREST") #! Field("COLL:LI18:962:MOTRVALREST.INP",16777215,0,"COLL:LI18:962:MOTRVALREST.INP") #! Link("COLL:LI18:962:MOTRVALREST.INP","COLL:LI18:962:MOTR.VAL") record(bi,"WIRE:LI18:944:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI18:944:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI18:944:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:144:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:144:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:144:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:244:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:244:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:244:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:344:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:344:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI19:344:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:960:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:960:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:960:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:961:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:961:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:961:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:962:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:962:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:962:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:963:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:963:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"COLL:LI18:963:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(calcout, "WIRE:LI18:944:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI18:944:MOTR.RBV") field(INPB, "WIRE:LI18:944:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI18:944:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI18:944:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI19:144:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI19:144:MOTR.RBV") field(INPB, "WIRE:LI19:144:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI19:144:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI19:144:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI19:244:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI19:244:MOTR.RBV") field(INPB, "WIRE:LI19:244:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI19:244:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI19:244:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI19:344:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI19:344:MOTR.RBV") field(INPB, "WIRE:LI19:344:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI19:344:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI19:344:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:960:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "COLL:LI18:960:MOTR.RBV") field(INPB, "COLL:LI18:960:LVPOS") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:960:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "COLL:LI18:960:MOTR.DMOV") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:961:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "COLL:LI18:961:MOTR.RBV") field(INPB, "COLL:LI18:961:LVPOS") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:961:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "COLL:LI18:961:MOTR.DMOV") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:962:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "COLL:LI18:962:MOTR.RBV") field(INPB, "COLL:LI18:962:LVPOS") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:962:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "COLL:LI18:962:MOTR.DMOV") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:963:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "COLL:LI18:963:MOTR.RBV") field(INPB, "COLL:LI18:963:LVPOS") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "COLL:LI18:963:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "COLL:LI18:963:MOTR.DMOV") field(HIGH, "0.2") field(LOW, "-0.2") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI18:944:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 0)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI18:944:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 0)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI18:944:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI18:944:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI18:944:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI18:944:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI18:944:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI18:944:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI18:944:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI18:944:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI18:944:POWER",20,14,0,0,"WIRE:LI18:944:POWER") #! Record("WIRE:LI18:944:BRAKE",260,14,0,0,"WIRE:LI18:944:BRAKE") #! Record("WIRE:LI18:944:POSN",500,5,0,0,"WIRE:LI18:944:POSN") #! Field("WIRE:LI18:944:POSN.FLNK",16777215,1,"WIRE:LI18:944:POSN.FLNK") #! Record("WIRE:LI18:944:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI18:944:FIRMWARE_VERSION") #! Record("WIRE:LI18:944:EN_POSN",980,28,0,0,"WIRE:LI18:944:EN_POSN") #! Record("WIRE:LI18:944:LOWLMT",1220,22,0,0,"WIRE:LI18:944:LOWLMT") #! Record("WIRE:LI18:944:HIGHLMT",1460,22,0,0,"WIRE:LI18:944:HIGHLMT") #! Record("WIRE:LI18:944:DONE",1700,22,0,0,"WIRE:LI18:944:DONE") #! Record("WIRE:LI18:944:HOMELMT",1940,22,0,0,"WIRE:LI18:944:HOMELMT") #! Record("WIRE:LI18:944:FAULT",2180,22,0,0,"WIRE:LI18:944:FAULT") #! Record("WIRE:LI18:944:HASENCODER",2420,22,0,0,"WIRE:LI18:944:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI19:144:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 1)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI19:144:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 1)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI19:144:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI19:144:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI19:144:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI19:144:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI19:144:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI19:144:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI19:144:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI19:144:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI19:144:POWER",20,14,0,0,"WIRE:LI19:144:POWER") #! Record("WIRE:LI19:144:BRAKE",260,14,0,0,"WIRE:LI19:144:BRAKE") #! Record("WIRE:LI19:144:POSN",500,5,0,0,"WIRE:LI19:144:POSN") #! Field("WIRE:LI19:144:POSN.FLNK",16777215,1,"WIRE:LI19:144:POSN.FLNK") #! Record("WIRE:LI19:144:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI19:144:FIRMWARE_VERSION") #! Record("WIRE:LI19:144:EN_POSN",980,28,0,0,"WIRE:LI19:144:EN_POSN") #! Record("WIRE:LI19:144:LOWLMT",1220,22,0,0,"WIRE:LI19:144:LOWLMT") #! Record("WIRE:LI19:144:HIGHLMT",1460,22,0,0,"WIRE:LI19:144:HIGHLMT") #! Record("WIRE:LI19:144:DONE",1700,22,0,0,"WIRE:LI19:144:DONE") #! Record("WIRE:LI19:144:HOMELMT",1940,22,0,0,"WIRE:LI19:144:HOMELMT") #! Record("WIRE:LI19:144:FAULT",2180,22,0,0,"WIRE:LI19:144:FAULT") #! Record("WIRE:LI19:144:HASENCODER",2420,22,0,0,"WIRE:LI19:144:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI19:244:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 2)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI19:244:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 2)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI19:244:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI19:244:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI19:244:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI19:244:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI19:244:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI19:244:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI19:244:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI19:244:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI19:244:POWER",20,14,0,0,"WIRE:LI19:244:POWER") #! Record("WIRE:LI19:244:BRAKE",260,14,0,0,"WIRE:LI19:244:BRAKE") #! Record("WIRE:LI19:244:POSN",500,5,0,0,"WIRE:LI19:244:POSN") #! Field("WIRE:LI19:244:POSN.FLNK",16777215,1,"WIRE:LI19:244:POSN.FLNK") #! Record("WIRE:LI19:244:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI19:244:FIRMWARE_VERSION") #! Record("WIRE:LI19:244:EN_POSN",980,28,0,0,"WIRE:LI19:244:EN_POSN") #! Record("WIRE:LI19:244:LOWLMT",1220,22,0,0,"WIRE:LI19:244:LOWLMT") #! Record("WIRE:LI19:244:HIGHLMT",1460,22,0,0,"WIRE:LI19:244:HIGHLMT") #! Record("WIRE:LI19:244:DONE",1700,22,0,0,"WIRE:LI19:244:DONE") #! Record("WIRE:LI19:244:HOMELMT",1940,22,0,0,"WIRE:LI19:244:HOMELMT") #! Record("WIRE:LI19:244:FAULT",2180,22,0,0,"WIRE:LI19:244:FAULT") #! Record("WIRE:LI19:244:HASENCODER",2420,22,0,0,"WIRE:LI19:244:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI19:344:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 3)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI19:344:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 3)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI19:344:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI19:344:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI19:344:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI19:344:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI19:344:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI19:344:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI19:344:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI19:344:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 3) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI19:344:POWER",20,14,0,0,"WIRE:LI19:344:POWER") #! Record("WIRE:LI19:344:BRAKE",260,14,0,0,"WIRE:LI19:344:BRAKE") #! Record("WIRE:LI19:344:POSN",500,5,0,0,"WIRE:LI19:344:POSN") #! Field("WIRE:LI19:344:POSN.FLNK",16777215,1,"WIRE:LI19:344:POSN.FLNK") #! Record("WIRE:LI19:344:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI19:344:FIRMWARE_VERSION") #! Record("WIRE:LI19:344:EN_POSN",980,28,0,0,"WIRE:LI19:344:EN_POSN") #! Record("WIRE:LI19:344:LOWLMT",1220,22,0,0,"WIRE:LI19:344:LOWLMT") #! Record("WIRE:LI19:344:HIGHLMT",1460,22,0,0,"WIRE:LI19:344:HIGHLMT") #! Record("WIRE:LI19:344:DONE",1700,22,0,0,"WIRE:LI19:344:DONE") #! Record("WIRE:LI19:344:HOMELMT",1940,22,0,0,"WIRE:LI19:344:HOMELMT") #! Record("WIRE:LI19:344:FAULT",2180,22,0,0,"WIRE:LI19:344:FAULT") #! Record("WIRE:LI19:344:HASENCODER",2420,22,0,0,"WIRE:LI19:344:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "COLL:LI18:961:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 0)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "COLL:LI18:961:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 0)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "COLL:LI18:961:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "COLL:LI18:961:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "COLL:LI18:961:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0) MOTOR_STATUS_LOW_LIMIT") } record(ai, "COLL:LI18:961:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "COLL:LI18:961:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0) MOTOR_STATUS_DONE") } record(ai, "COLL:LI18:961:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0) MOTOR_STATUS_AT_HOME") } record(ai, "COLL:LI18:961:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0) MOTOR_STATUS_PROBLEM") } record(ai, "COLL:LI18:961:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 0) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("COLL:LI18:961:POWER",20,14,0,0,"COLL:LI18:961:POWER") #! Record("COLL:LI18:961:BRAKE",260,14,0,0,"COLL:LI18:961:BRAKE") #! Record("COLL:LI18:961:POSN",500,5,0,0,"COLL:LI18:961:POSN") #! Field("COLL:LI18:961:POSN.FLNK",16777215,1,"COLL:LI18:961:POSN.FLNK") #! Record("COLL:LI18:961:FIRMWARE_VERSION",740,28,0,0,"COLL:LI18:961:FIRMWARE_VERSION") #! Record("COLL:LI18:961:EN_POSN",980,28,0,0,"COLL:LI18:961:EN_POSN") #! Record("COLL:LI18:961:LOWLMT",1220,22,0,0,"COLL:LI18:961:LOWLMT") #! Record("COLL:LI18:961:HIGHLMT",1460,22,0,0,"COLL:LI18:961:HIGHLMT") #! Record("COLL:LI18:961:DONE",1700,22,0,0,"COLL:LI18:961:DONE") #! Record("COLL:LI18:961:HOMELMT",1940,22,0,0,"COLL:LI18:961:HOMELMT") #! Record("COLL:LI18:961:FAULT",2180,22,0,0,"COLL:LI18:961:FAULT") #! Record("COLL:LI18:961:HASENCODER",2420,22,0,0,"COLL:LI18:961:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "COLL:LI18:960:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 1)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "COLL:LI18:960:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 1)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "COLL:LI18:960:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "COLL:LI18:960:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "COLL:LI18:960:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1) MOTOR_STATUS_LOW_LIMIT") } record(ai, "COLL:LI18:960:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "COLL:LI18:960:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1) MOTOR_STATUS_DONE") } record(ai, "COLL:LI18:960:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1) MOTOR_STATUS_AT_HOME") } record(ai, "COLL:LI18:960:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1) MOTOR_STATUS_PROBLEM") } record(ai, "COLL:LI18:960:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 1) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("COLL:LI18:960:POWER",20,14,0,0,"COLL:LI18:960:POWER") #! Record("COLL:LI18:960:BRAKE",260,14,0,0,"COLL:LI18:960:BRAKE") #! Record("COLL:LI18:960:POSN",500,5,0,0,"COLL:LI18:960:POSN") #! Field("COLL:LI18:960:POSN.FLNK",16777215,1,"COLL:LI18:960:POSN.FLNK") #! Record("COLL:LI18:960:FIRMWARE_VERSION",740,28,0,0,"COLL:LI18:960:FIRMWARE_VERSION") #! Record("COLL:LI18:960:EN_POSN",980,28,0,0,"COLL:LI18:960:EN_POSN") #! Record("COLL:LI18:960:LOWLMT",1220,22,0,0,"COLL:LI18:960:LOWLMT") #! Record("COLL:LI18:960:HIGHLMT",1460,22,0,0,"COLL:LI18:960:HIGHLMT") #! Record("COLL:LI18:960:DONE",1700,22,0,0,"COLL:LI18:960:DONE") #! Record("COLL:LI18:960:HOMELMT",1940,22,0,0,"COLL:LI18:960:HOMELMT") #! Record("COLL:LI18:960:FAULT",2180,22,0,0,"COLL:LI18:960:FAULT") #! Record("COLL:LI18:960:HASENCODER",2420,22,0,0,"COLL:LI18:960:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "COLL:LI18:963:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 2)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "COLL:LI18:963:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 2)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "COLL:LI18:963:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "COLL:LI18:963:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "COLL:LI18:963:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2) MOTOR_STATUS_LOW_LIMIT") } record(ai, "COLL:LI18:963:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "COLL:LI18:963:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2) MOTOR_STATUS_DONE") } record(ai, "COLL:LI18:963:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2) MOTOR_STATUS_AT_HOME") } record(ai, "COLL:LI18:963:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2) MOTOR_STATUS_PROBLEM") } record(ai, "COLL:LI18:963:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 2) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("COLL:LI18:963:POWER",20,14,0,0,"COLL:LI18:963:POWER") #! Record("COLL:LI18:963:BRAKE",260,14,0,0,"COLL:LI18:963:BRAKE") #! Record("COLL:LI18:963:POSN",500,5,0,0,"COLL:LI18:963:POSN") #! Field("COLL:LI18:963:POSN.FLNK",16777215,1,"COLL:LI18:963:POSN.FLNK") #! Record("COLL:LI18:963:FIRMWARE_VERSION",740,28,0,0,"COLL:LI18:963:FIRMWARE_VERSION") #! Record("COLL:LI18:963:EN_POSN",980,28,0,0,"COLL:LI18:963:EN_POSN") #! Record("COLL:LI18:963:LOWLMT",1220,22,0,0,"COLL:LI18:963:LOWLMT") #! Record("COLL:LI18:963:HIGHLMT",1460,22,0,0,"COLL:LI18:963:HIGHLMT") #! Record("COLL:LI18:963:DONE",1700,22,0,0,"COLL:LI18:963:DONE") #! Record("COLL:LI18:963:HOMELMT",1940,22,0,0,"COLL:LI18:963:HOMELMT") #! Record("COLL:LI18:963:FAULT",2180,22,0,0,"COLL:LI18:963:FAULT") #! Record("COLL:LI18:963:HASENCODER",2420,22,0,0,"COLL:LI18:963:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "COLL:LI18:962:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 3)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "COLL:LI18:962:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-02 3)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "COLL:LI18:962:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "COLL:LI18:962:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "COLL:LI18:962:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3) MOTOR_STATUS_LOW_LIMIT") } record(ai, "COLL:LI18:962:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "COLL:LI18:962:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3) MOTOR_STATUS_DONE") } record(ai, "COLL:LI18:962:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3) MOTOR_STATUS_AT_HOME") } record(ai, "COLL:LI18:962:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3) MOTOR_STATUS_PROBLEM") } record(ai, "COLL:LI18:962:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-02 3) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("COLL:LI18:962:POWER",20,14,0,0,"COLL:LI18:962:POWER") #! Record("COLL:LI18:962:BRAKE",260,14,0,0,"COLL:LI18:962:BRAKE") #! Record("COLL:LI18:962:POSN",500,5,0,0,"COLL:LI18:962:POSN") #! Field("COLL:LI18:962:POSN.FLNK",16777215,1,"COLL:LI18:962:POSN.FLNK") #! Record("COLL:LI18:962:FIRMWARE_VERSION",740,28,0,0,"COLL:LI18:962:FIRMWARE_VERSION") #! Record("COLL:LI18:962:EN_POSN",980,28,0,0,"COLL:LI18:962:EN_POSN") #! Record("COLL:LI18:962:LOWLMT",1220,22,0,0,"COLL:LI18:962:LOWLMT") #! Record("COLL:LI18:962:HIGHLMT",1460,22,0,0,"COLL:LI18:962:HIGHLMT") #! Record("COLL:LI18:962:DONE",1700,22,0,0,"COLL:LI18:962:DONE") #! Record("COLL:LI18:962:HOMELMT",1940,22,0,0,"COLL:LI18:962:HOMELMT") #! Record("COLL:LI18:962:FAULT",2180,22,0,0,"COLL:LI18:962:FAULT") #! Record("COLL:LI18:962:HASENCODER",2420,22,0,0,"COLL:LI18:962:HASENCODER")