#! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/0 record(motor, "WIRE:LI11:614:MOTR") { field(DESC, "WS11614 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 0)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI11:614:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI11:614:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI11:614 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI11:614:POSN") { field(DESC, "WS11614 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 0)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI11:614:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI11:614 (WS11614) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI11:614:MASK") { field(DESC, "WS11614 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI11:614:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI11:614 (WS11614) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI11:614:NEWOFFS") { field(DESC, "New WS11614 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI11:614:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI11:614:POSN.EOFF") } record(ao, "WIRE:LI11:614:MOTRVAL") { field(DESC, "WS11614 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI11:614:MOTR.VAL") field(FLNK, "WIRE:LI11:614:MOTR") } record(ao, "WIRE:LI11:614:MOTRHI") { field(DESC, "Move WS11614 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI11:614:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI11:614:MOTR.VAL") field(FLNK, "WIRE:LI11:614:MOTR") } record(ao, "WIRE:LI11:614:MOTRLO") { field(DESC, "Move WS11614 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI11:614:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI11:614:MOTR.VAL") field(FLNK, "WIRE:LI11:614:MOTR") } record(ao, "WIRE:LI11:614:RETRACT") { field(DESC, "WS11614 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI11:614:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI11:614:MOTR.VAL") field(FLNK, "WIRE:LI11:614:MOTR") } record(ai, "WIRE:LI11:614:RETRACT_POSN") { field(DESC, "WS11614 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI11:614:MOTRVELCHOICE") { field(DESC, "WS11614 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI11:614:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI11:614:SYNCMOTPROFILE") { field(DESC, "WS11614 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI11:614:MOTPROFILE") field(LNK2, "WIRE:LI11:614:LVDTPROFILE") field(LNK3, "WIRE:LI11:614:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI11:614:CALIBSYNC") { field(DESC, "WS11614 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI11:614:MOTPROFILE") { field(DESC, "WS11614 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI11:614:POSN PP") } record(compress, "WIRE:LI11:614:LVDTPROFILE") { field(DESC, "WS11614 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI11:614:LVRAW PP") } record(subArray, "WIRE:LI11:614:SUBLPROF") { field(DESC, "WS11614 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI11:614:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI11:614:SUBMPROF") { field(DESC, "WS11614 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI11:614:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI11:614:PMOTPROFILE") { field(DESC, "WS11614 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI11:614:MOTPROFILE") field(FLNK, "WIRE:LI11:614:SUBMPROF") } record(waveform, "WIRE:LI11:614:PLVDTPROFILE") { field(DESC, "WS11614 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI11:614:LVDTPROFILE") field(FLNK, "WIRE:LI11:614:SUBLPROF") } record(ai, "WIRE:LI11:614:MOTRVALREST") { field(INP, "WIRE:LI11:614:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI11:614:MOTR",160,62,0,0,"WIRE:LI11:614:MOTR") #! Field("WIRE:LI11:614:MOTR.FLNK",16777215,1,"WIRE:LI11:614:MOTR.FLNK") #! Field("WIRE:LI11:614:MOTR.RDBL",16777215,1,"WIRE:LI11:614:MOTR.RDBL") #! Field("WIRE:LI11:614:MOTR.OFF",16777215,1,"WIRE:LI11:614:MOTR.OFF") #! Field("WIRE:LI11:614:MOTR.HLM",16777215,1,"WIRE:LI11:614:MOTR.HLM") #! Field("WIRE:LI11:614:MOTR.LLM",16777215,1,"WIRE:LI11:614:MOTR.LLM") #! Field("WIRE:LI11:614:MOTR.VELO",16777215,1,"WIRE:LI11:614:MOTR.VELO") #! Field("WIRE:LI11:614:MOTR.VAL",16777215,1,"WIRE:LI11:614:MOTR.VAL") #! Record("WIRE:LI11:614:POSN",1000,544,0,0,"WIRE:LI11:614:POSN") #! Field("WIRE:LI11:614:POSN.FLNK",16777215,1,"WIRE:LI11:614:POSN.FLNK") #! Field("WIRE:LI11:614:POSN.EOFF",16777215,0,"WIRE:LI11:614:POSN.EOFF") #! Field("WIRE:LI11:614:POSN.VAL",16777215,1,"WIRE:LI11:614:POSN.VAL") #! Record("WIRE:LI11:614:MASK",1340,1352,0,0,"WIRE:LI11:614:MASK") #! Field("WIRE:LI11:614:MASK.FLNK",16777215,1,"WIRE:LI11:614:MASK.FLNK") #! Record("WIRE:LI11:614:NEWOFFS",720,612,0,0,"WIRE:LI11:614:NEWOFFS") #! Field("WIRE:LI11:614:NEWOFFS.DOL",16777215,0,"WIRE:LI11:614:NEWOFFS.DOL") #! Link("WIRE:LI11:614:NEWOFFS.DOL","WIRE:LI11:614:MOTR.OFF") #! Field("WIRE:LI11:614:NEWOFFS.OUT",16777215,1,"WIRE:LI11:614:NEWOFFS.OUT") #! Link("WIRE:LI11:614:NEWOFFS.OUT","WIRE:LI11:614:POSN.EOFF") #! Record("WIRE:LI11:614:MOTRVAL",860,986,0,0,"WIRE:LI11:614:MOTRVAL") #! Field("WIRE:LI11:614:MOTRVAL.OUT",16777215,0,"WIRE:LI11:614:MOTRVAL.OUT") #! Link("WIRE:LI11:614:MOTRVAL.OUT","WIRE:LI11:614:MOTR.VAL") #! Field("WIRE:LI11:614:MOTRVAL.FLNK",16777215,0,"WIRE:LI11:614:MOTRVAL.FLNK") #! Link("WIRE:LI11:614:MOTRVAL.FLNK","WIRE:LI11:614:MOTR") #! Record("WIRE:LI11:614:MOTRHI",860,1238,0,0,"WIRE:LI11:614:MOTRHI") #! Field("WIRE:LI11:614:MOTRHI.DOL",16777215,0,"WIRE:LI11:614:MOTRHI.DOL") #! Link("WIRE:LI11:614:MOTRHI.DOL","WIRE:LI11:614:MOTR.HLM") #! Field("WIRE:LI11:614:MOTRHI.OUT",16777215,0,"WIRE:LI11:614:MOTRHI.OUT") #! Link("WIRE:LI11:614:MOTRHI.OUT","WIRE:LI11:614:MOTR.VAL") #! Field("WIRE:LI11:614:MOTRHI.FLNK",16777215,0,"WIRE:LI11:614:MOTRHI.FLNK") #! Link("WIRE:LI11:614:MOTRHI.FLNK","WIRE:LI11:614:MOTR") #! Record("WIRE:LI11:614:MOTRLO",860,1558,0,0,"WIRE:LI11:614:MOTRLO") #! Field("WIRE:LI11:614:MOTRLO.DOL",16777215,0,"WIRE:LI11:614:MOTRLO.DOL") #! Link("WIRE:LI11:614:MOTRLO.DOL","WIRE:LI11:614:MOTR.LLM") #! Field("WIRE:LI11:614:MOTRLO.OUT",16777215,0,"WIRE:LI11:614:MOTRLO.OUT") #! Link("WIRE:LI11:614:MOTRLO.OUT","WIRE:LI11:614:MOTR.VAL") #! Field("WIRE:LI11:614:MOTRLO.FLNK",16777215,0,"WIRE:LI11:614:MOTRLO.FLNK") #! Link("WIRE:LI11:614:MOTRLO.FLNK","WIRE:LI11:614:MOTR") #! Record("WIRE:LI11:614:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI11:614:MOTRVELCHOICE") #! Field("WIRE:LI11:614:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI11:614:MOTRVELCHOICE.OUT") #! Link("WIRE:LI11:614:MOTRVELCHOICE.OUT","WIRE:LI11:614:MOTR.VELO") #! Record("WIRE:LI11:614:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI11:614:SYNCMOTPROFILE") #! Field("WIRE:LI11:614:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI11:614:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI11:614:SYNCMOTPROFILE.LNK1","WIRE:LI11:614:MOTPROFILE") #! Field("WIRE:LI11:614:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI11:614:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI11:614:SYNCMOTPROFILE.LNK2","WIRE:LI11:614:LVDTPROFILE") #! Field("WIRE:LI11:614:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI11:614:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI11:614:SYNCMOTPROFILE.LNK3","WIRE:LI11:614:CALIBSYNC") #! Record("WIRE:LI11:614:CALIBSYNC",1980,860,0,0,"WIRE:LI11:614:CALIBSYNC") #! Record("WIRE:LI11:614:MOTPROFILE",1380,706,0,1,"WIRE:LI11:614:MOTPROFILE") #! Field("WIRE:LI11:614:MOTPROFILE.INP",16777215,0,"WIRE:LI11:614:MOTPROFILE.INP") #! Link("WIRE:LI11:614:MOTPROFILE.INP","WIRE:LI11:614:POSN.VAL") #! Field("WIRE:LI11:614:MOTPROFILE.VAL",16777215,0,"WIRE:LI11:614:MOTPROFILE.VAL") #! Record("WIRE:LI11:614:LVDTPROFILE",2000,566,0,0,"WIRE:LI11:614:LVDTPROFILE") #! Field("WIRE:LI11:614:LVDTPROFILE.INP",16777215,1,"WIRE:LI11:614:LVDTPROFILE.INP") #! Field("WIRE:LI11:614:LVDTPROFILE.VAL",16777215,1,"WIRE:LI11:614:LVDTPROFILE.VAL") #! Record("WIRE:LI11:614:SUBLPROF",2560,698,0,0,"WIRE:LI11:614:SUBLPROF") #! Field("WIRE:LI11:614:SUBLPROF.INP",16777215,0,"WIRE:LI11:614:SUBLPROF.INP") #! Link("WIRE:LI11:614:SUBLPROF.INP","WIRE:LI11:614:PLVDTPROFILE.VAL") #! Record("WIRE:LI11:614:SUBMPROF",1700,1078,0,0,"WIRE:LI11:614:SUBMPROF") #! Field("WIRE:LI11:614:SUBMPROF.INP",16777215,0,"WIRE:LI11:614:SUBMPROF.INP") #! Link("WIRE:LI11:614:SUBMPROF.INP","WIRE:LI11:614:PMOTPROFILE.VAL") #! Record("WIRE:LI11:614:PMOTPROFILE",1380,998,0,0,"WIRE:LI11:614:PMOTPROFILE") #! Field("WIRE:LI11:614:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI11:614:PMOTPROFILE.FLNK") #! Link("WIRE:LI11:614:PMOTPROFILE.FLNK","WIRE:LI11:614:SUBMPROF") #! Field("WIRE:LI11:614:PMOTPROFILE.VAL",16777215,1,"WIRE:LI11:614:PMOTPROFILE.VAL") #! Field("WIRE:LI11:614:PMOTPROFILE.INP",16777215,0,"WIRE:LI11:614:PMOTPROFILE.INP") #! Link("WIRE:LI11:614:PMOTPROFILE.INP","WIRE:LI11:614:MOTPROFILE.VAL") #! Record("WIRE:LI11:614:PLVDTPROFILE",2280,578,0,0,"WIRE:LI11:614:PLVDTPROFILE") #! Field("WIRE:LI11:614:PLVDTPROFILE.INP",16777215,0,"WIRE:LI11:614:PLVDTPROFILE.INP") #! Link("WIRE:LI11:614:PLVDTPROFILE.INP","WIRE:LI11:614:LVDTPROFILE.VAL") #! Field("WIRE:LI11:614:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI11:614:PLVDTPROFILE.FLNK") #! Link("WIRE:LI11:614:PLVDTPROFILE.FLNK","WIRE:LI11:614:SUBLPROF") #! Field("WIRE:LI11:614:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI11:614:PLVDTPROFILE.VAL") #! Record("WIRE:LI11:614:MOTRVALREST",500,914,0,0,"WIRE:LI11:614:MOTRVALREST") #! Field("WIRE:LI11:614:MOTRVALREST.INP",16777215,0,"WIRE:LI11:614:MOTRVALREST.INP") #! Link("WIRE:LI11:614:MOTRVALREST.INP","WIRE:LI11:614:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/1 record(motor, "WIRE:LI11:744:MOTR") { field(DESC, "WS11744 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 1)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI11:744:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI11:744:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI11:744 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI11:744:POSN") { field(DESC, "WS11744 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 1)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI11:744:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI11:744 (WS11744) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI11:744:MASK") { field(DESC, "WS11744 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI11:744:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI11:744 (WS11744) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI11:744:NEWOFFS") { field(DESC, "New WS11744 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI11:744:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI11:744:POSN.EOFF") } record(ao, "WIRE:LI11:744:MOTRVAL") { field(DESC, "WS11744 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI11:744:MOTR.VAL") field(FLNK, "WIRE:LI11:744:MOTR") } record(ao, "WIRE:LI11:744:MOTRHI") { field(DESC, "Move WS11744 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI11:744:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI11:744:MOTR.VAL") field(FLNK, "WIRE:LI11:744:MOTR") } record(ao, "WIRE:LI11:744:MOTRLO") { field(DESC, "Move WS11744 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI11:744:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI11:744:MOTR.VAL") field(FLNK, "WIRE:LI11:744:MOTR") } record(ao, "WIRE:LI11:744:RETRACT") { field(DESC, "WS11744 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI11:744:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI11:744:MOTR.VAL") field(FLNK, "WIRE:LI11:744:MOTR") } record(ai, "WIRE:LI11:744:RETRACT_POSN") { field(DESC, "WS11744 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI11:744:MOTRVELCHOICE") { field(DESC, "WS11744 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI11:744:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI11:744:SYNCMOTPROFILE") { field(DESC, "WS11744 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI11:744:MOTPROFILE") field(LNK2, "WIRE:LI11:744:LVDTPROFILE") field(LNK3, "WIRE:LI11:744:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI11:744:CALIBSYNC") { field(DESC, "WS11744 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI11:744:MOTPROFILE") { field(DESC, "WS11744 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI11:744:POSN PP") } record(compress, "WIRE:LI11:744:LVDTPROFILE") { field(DESC, "WS11744 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI11:744:LVRAW PP") } record(subArray, "WIRE:LI11:744:SUBLPROF") { field(DESC, "WS11744 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI11:744:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI11:744:SUBMPROF") { field(DESC, "WS11744 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI11:744:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI11:744:PMOTPROFILE") { field(DESC, "WS11744 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI11:744:MOTPROFILE") field(FLNK, "WIRE:LI11:744:SUBMPROF") } record(waveform, "WIRE:LI11:744:PLVDTPROFILE") { field(DESC, "WS11744 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI11:744:LVDTPROFILE") field(FLNK, "WIRE:LI11:744:SUBLPROF") } record(ai, "WIRE:LI11:744:MOTRVALREST") { field(INP, "WIRE:LI11:744:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI11:744:MOTR",160,62,0,0,"WIRE:LI11:744:MOTR") #! Field("WIRE:LI11:744:MOTR.FLNK",16777215,1,"WIRE:LI11:744:MOTR.FLNK") #! Field("WIRE:LI11:744:MOTR.RDBL",16777215,1,"WIRE:LI11:744:MOTR.RDBL") #! Field("WIRE:LI11:744:MOTR.OFF",16777215,1,"WIRE:LI11:744:MOTR.OFF") #! Field("WIRE:LI11:744:MOTR.HLM",16777215,1,"WIRE:LI11:744:MOTR.HLM") #! Field("WIRE:LI11:744:MOTR.LLM",16777215,1,"WIRE:LI11:744:MOTR.LLM") #! Field("WIRE:LI11:744:MOTR.VELO",16777215,1,"WIRE:LI11:744:MOTR.VELO") #! Field("WIRE:LI11:744:MOTR.VAL",16777215,1,"WIRE:LI11:744:MOTR.VAL") #! Record("WIRE:LI11:744:POSN",1000,544,0,0,"WIRE:LI11:744:POSN") #! Field("WIRE:LI11:744:POSN.FLNK",16777215,1,"WIRE:LI11:744:POSN.FLNK") #! Field("WIRE:LI11:744:POSN.EOFF",16777215,0,"WIRE:LI11:744:POSN.EOFF") #! Field("WIRE:LI11:744:POSN.VAL",16777215,1,"WIRE:LI11:744:POSN.VAL") #! Record("WIRE:LI11:744:MASK",1340,1352,0,0,"WIRE:LI11:744:MASK") #! Field("WIRE:LI11:744:MASK.FLNK",16777215,1,"WIRE:LI11:744:MASK.FLNK") #! Record("WIRE:LI11:744:NEWOFFS",720,612,0,0,"WIRE:LI11:744:NEWOFFS") #! Field("WIRE:LI11:744:NEWOFFS.DOL",16777215,0,"WIRE:LI11:744:NEWOFFS.DOL") #! Link("WIRE:LI11:744:NEWOFFS.DOL","WIRE:LI11:744:MOTR.OFF") #! Field("WIRE:LI11:744:NEWOFFS.OUT",16777215,1,"WIRE:LI11:744:NEWOFFS.OUT") #! Link("WIRE:LI11:744:NEWOFFS.OUT","WIRE:LI11:744:POSN.EOFF") #! Record("WIRE:LI11:744:MOTRVAL",860,986,0,0,"WIRE:LI11:744:MOTRVAL") #! Field("WIRE:LI11:744:MOTRVAL.OUT",16777215,0,"WIRE:LI11:744:MOTRVAL.OUT") #! Link("WIRE:LI11:744:MOTRVAL.OUT","WIRE:LI11:744:MOTR.VAL") #! Field("WIRE:LI11:744:MOTRVAL.FLNK",16777215,0,"WIRE:LI11:744:MOTRVAL.FLNK") #! Link("WIRE:LI11:744:MOTRVAL.FLNK","WIRE:LI11:744:MOTR") #! Record("WIRE:LI11:744:MOTRHI",860,1238,0,0,"WIRE:LI11:744:MOTRHI") #! Field("WIRE:LI11:744:MOTRHI.DOL",16777215,0,"WIRE:LI11:744:MOTRHI.DOL") #! Link("WIRE:LI11:744:MOTRHI.DOL","WIRE:LI11:744:MOTR.HLM") #! Field("WIRE:LI11:744:MOTRHI.OUT",16777215,0,"WIRE:LI11:744:MOTRHI.OUT") #! Link("WIRE:LI11:744:MOTRHI.OUT","WIRE:LI11:744:MOTR.VAL") #! Field("WIRE:LI11:744:MOTRHI.FLNK",16777215,0,"WIRE:LI11:744:MOTRHI.FLNK") #! Link("WIRE:LI11:744:MOTRHI.FLNK","WIRE:LI11:744:MOTR") #! Record("WIRE:LI11:744:MOTRLO",860,1558,0,0,"WIRE:LI11:744:MOTRLO") #! Field("WIRE:LI11:744:MOTRLO.DOL",16777215,0,"WIRE:LI11:744:MOTRLO.DOL") #! Link("WIRE:LI11:744:MOTRLO.DOL","WIRE:LI11:744:MOTR.LLM") #! Field("WIRE:LI11:744:MOTRLO.OUT",16777215,0,"WIRE:LI11:744:MOTRLO.OUT") #! Link("WIRE:LI11:744:MOTRLO.OUT","WIRE:LI11:744:MOTR.VAL") #! Field("WIRE:LI11:744:MOTRLO.FLNK",16777215,0,"WIRE:LI11:744:MOTRLO.FLNK") #! Link("WIRE:LI11:744:MOTRLO.FLNK","WIRE:LI11:744:MOTR") #! Record("WIRE:LI11:744:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI11:744:MOTRVELCHOICE") #! Field("WIRE:LI11:744:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI11:744:MOTRVELCHOICE.OUT") #! Link("WIRE:LI11:744:MOTRVELCHOICE.OUT","WIRE:LI11:744:MOTR.VELO") #! Record("WIRE:LI11:744:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI11:744:SYNCMOTPROFILE") #! Field("WIRE:LI11:744:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI11:744:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI11:744:SYNCMOTPROFILE.LNK1","WIRE:LI11:744:MOTPROFILE") #! Field("WIRE:LI11:744:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI11:744:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI11:744:SYNCMOTPROFILE.LNK2","WIRE:LI11:744:LVDTPROFILE") #! Field("WIRE:LI11:744:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI11:744:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI11:744:SYNCMOTPROFILE.LNK3","WIRE:LI11:744:CALIBSYNC") #! Record("WIRE:LI11:744:CALIBSYNC",1980,860,0,0,"WIRE:LI11:744:CALIBSYNC") #! Record("WIRE:LI11:744:MOTPROFILE",1380,706,0,1,"WIRE:LI11:744:MOTPROFILE") #! Field("WIRE:LI11:744:MOTPROFILE.INP",16777215,0,"WIRE:LI11:744:MOTPROFILE.INP") #! Link("WIRE:LI11:744:MOTPROFILE.INP","WIRE:LI11:744:POSN.VAL") #! Field("WIRE:LI11:744:MOTPROFILE.VAL",16777215,0,"WIRE:LI11:744:MOTPROFILE.VAL") #! Record("WIRE:LI11:744:LVDTPROFILE",2000,566,0,0,"WIRE:LI11:744:LVDTPROFILE") #! Field("WIRE:LI11:744:LVDTPROFILE.INP",16777215,1,"WIRE:LI11:744:LVDTPROFILE.INP") #! Field("WIRE:LI11:744:LVDTPROFILE.VAL",16777215,1,"WIRE:LI11:744:LVDTPROFILE.VAL") #! Record("WIRE:LI11:744:SUBLPROF",2560,698,0,0,"WIRE:LI11:744:SUBLPROF") #! Field("WIRE:LI11:744:SUBLPROF.INP",16777215,0,"WIRE:LI11:744:SUBLPROF.INP") #! Link("WIRE:LI11:744:SUBLPROF.INP","WIRE:LI11:744:PLVDTPROFILE.VAL") #! Record("WIRE:LI11:744:SUBMPROF",1700,1078,0,0,"WIRE:LI11:744:SUBMPROF") #! Field("WIRE:LI11:744:SUBMPROF.INP",16777215,0,"WIRE:LI11:744:SUBMPROF.INP") #! Link("WIRE:LI11:744:SUBMPROF.INP","WIRE:LI11:744:PMOTPROFILE.VAL") #! Record("WIRE:LI11:744:PMOTPROFILE",1380,998,0,0,"WIRE:LI11:744:PMOTPROFILE") #! Field("WIRE:LI11:744:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI11:744:PMOTPROFILE.FLNK") #! Link("WIRE:LI11:744:PMOTPROFILE.FLNK","WIRE:LI11:744:SUBMPROF") #! Field("WIRE:LI11:744:PMOTPROFILE.VAL",16777215,1,"WIRE:LI11:744:PMOTPROFILE.VAL") #! Field("WIRE:LI11:744:PMOTPROFILE.INP",16777215,0,"WIRE:LI11:744:PMOTPROFILE.INP") #! Link("WIRE:LI11:744:PMOTPROFILE.INP","WIRE:LI11:744:MOTPROFILE.VAL") #! Record("WIRE:LI11:744:PLVDTPROFILE",2280,578,0,0,"WIRE:LI11:744:PLVDTPROFILE") #! Field("WIRE:LI11:744:PLVDTPROFILE.INP",16777215,0,"WIRE:LI11:744:PLVDTPROFILE.INP") #! Link("WIRE:LI11:744:PLVDTPROFILE.INP","WIRE:LI11:744:LVDTPROFILE.VAL") #! Field("WIRE:LI11:744:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI11:744:PLVDTPROFILE.FLNK") #! Link("WIRE:LI11:744:PLVDTPROFILE.FLNK","WIRE:LI11:744:SUBLPROF") #! Field("WIRE:LI11:744:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI11:744:PLVDTPROFILE.VAL") #! Record("WIRE:LI11:744:MOTRVALREST",500,914,0,0,"WIRE:LI11:744:MOTRVALREST") #! Field("WIRE:LI11:744:MOTRVALREST.INP",16777215,0,"WIRE:LI11:744:MOTRVALREST.INP") #! Link("WIRE:LI11:744:MOTRVALREST.INP","WIRE:LI11:744:MOTR.VAL") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBD("../../../dbd/MotionControl.dbd") #! DBDEND # motor channel Hy8601-01/2 record(motor, "WIRE:LI12:214:MOTR") { field(DESC, "WS12214 Wire Scanner Motion") field(SCAN, "Passive") field(DIR, "Pos") field(DTYP, "asynMotor") field(VELO, "850") field(VBAS, "250") field(VMAX, "850") field(ACCL, "0.1") field(OUT, "@asyn( Hy8601-01, 2)") field(MRES, "0.5") field(SREV, "400") field(PREC, "0") field(EGU, "microns") field(DHLM, "28104") field(HOPR, "28104") field(DLLM, "-32092") field(LOPR, "-32092") field(DLY, "0") field(TWV, "1000") field(SET, "1") field(RDBD, "2") field(FOFF, "Frozen") field(FLNK, "WIRE:LI12:214:MOTRVALREST") field(PINI, "YES") field(PRIO, "HIGH") field(BDST, "0") field(BVEL, "250") field(BACC, "0.5") field(RDBL, "WIRE:LI12:214:LVPOS") info(autosaveFields, "DESC DIR VELO VBAS VMAX ACCL MRES SREV PREC EGU DHLM HOPR DLLM LOPR DLY TWV RDBD BDST BVEL BACC RDBL RRES RTRY URIP HIHI LOLO HIGH LOW HHSV LLSV HSV LSV") } # Position of motor on WIRE:LI12:214 # updated regularly, when a specific event arrives # from the event timing system, indicating that # beam has arrived. This is unused for collimators # or other simple motion devices; it is important # for wire scanners and other beam-synchronous # devices. # WARNING: The EVNT field is changed when calibrations # are performed. If problems are suspected with this, # check the save and restore code in the sequencer, # under calibrate.st, in the READY_TO_PROFILE state. record(ai, "WIRE:LI12:214:POSN") { field(DESC, "WS12214 Current Position") field(DTYP, "asynInt32") field(EGU, "microns") field(INP, "@asyn(Hy8601-01 2)MOTOR_POSITION") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(LINR, "SLOPE") field(ROFF, "0") field(EOFF, "0") field(ESLO, "0.15625") field(FLNK, "WIRE:LI12:214:EFPOSN") field(PREC, "0") field(TSE, "-1") info(autosaveFields, "ESLO") } # # This record contains a simple value that changes per # beam pulse; when WIRE:LI12:214 (WS12214) # is scanning, it will have a non-zero value, and when # moving to a start position or positioning to confirm # an LVDT value, it will be zero. # record(ao, "WIRE:LI12:214:MASK") { field(DESC, "WS12214 Scan Mask") field(OMSL, "supervisory") field(SCAN, "Event") field(PRIO, "HIGH") field(EVNT, "201") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(FLNK, "WIRE:LI12:214:EFMASK") field(TSE, "-1") } # # This record takes the calibration offset from # WIRE:LI12:214 (WS12214) and pushes # it to the EOFF field in the POSN record, above. # It is triggered by the state machine after a # calibration is complete, or when the IOC starts. # record(ao, "WIRE:LI12:214:NEWOFFS") { field(DESC, "New WS12214 Cal") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI12:214:MOTR.OFF PP") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI12:214:POSN.EOFF") } record(ao, "WIRE:LI12:214:MOTRVAL") { field(DESC, "WS12214 Value Proxy") field(EGU, "microns") field(OMSL, "supervisory") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI12:214:MOTR.VAL") field(FLNK, "WIRE:LI12:214:MOTR") } record(ao, "WIRE:LI12:214:MOTRHI") { field(DESC, "Move WS12214 High") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI12:214:MOTR.HLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI12:214:MOTR.VAL") field(FLNK, "WIRE:LI12:214:MOTR") } record(ao, "WIRE:LI12:214:MOTRLO") { field(DESC, "Move WS12214 Low") field(EGU, "microns") field(OMSL, "closed_loop") field(OIF, "Full") field(DOL, "WIRE:LI12:214:MOTR.LLM") field(DRVH, "4000000000") field(DRVL, "-4000000000") field(SCAN, "Passive") field(OUT, "WIRE:LI12:214:MOTR.VAL") field(FLNK, "WIRE:LI12:214:MOTR") } record(ao, "WIRE:LI12:214:RETRACT") { field(DESC, "WS12214 Retract") field(EGU, "microns") field(OMSL, "closed_loop") field(DOL, "WIRE:LI12:214:RETRACT_POSN") field(DRVH, "28104") field(DRVL, "-32092") field(SCAN, "Passive") field(OUT, "WIRE:LI12:214:MOTR.VAL") field(FLNK, "WIRE:LI12:214:MOTR") } record(ai, "WIRE:LI12:214:RETRACT_POSN") { field(DESC, "WS12214 Retract Position") field(VAL, "-32092") field(PINI, "YES") info(autosaveFields, "VAL") } record(mbbo, "WIRE:LI12:214:MOTRVELCHOICE") { field(DESC, "WS12214 Value Proxy") field(OMSL, "supervisory") field(SCAN, "Passive") field(DTYP, "Raw Soft Channel") field(NOBT, "32") field(OUT, "WIRE:LI12:214:MOTR.VELO") field(ZRST, "Normal") field(ZRVL, "500") field(ONST, "Maximum") field(ONVL, "850") field(TWST, "Medium") field(TWVL, "500") field(THST, "Slow") field(THVL, "250") } record(fanout, "WIRE:LI12:214:SYNCMOTPROFILE") { field(DESC, "WS12214 Calib Profile Sync") field(SCAN, "Passive") field(SELM, "Mask") field(SELL, "7") field(LNK1, "WIRE:LI12:214:MOTPROFILE") field(LNK2, "WIRE:LI12:214:LVDTPROFILE") field(LNK3, "WIRE:LI12:214:CALIBSYNC") } # # This record is processed at the end of an acquisition # sequence. The calibration state machine waits for it # to become 0. Specifically, it awaits processing. # record(event, "WIRE:LI12:214:CALIBSYNC") { field(DESC, "WS12214 Cal Delay Sync") field(VAL, "0") field(SCAN, "Passive") field(PINI, "YES") } record(compress, "WIRE:LI12:214:MOTPROFILE") { field(DESC, "WS12214 Motion Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI12:214:POSN PP") } record(compress, "WIRE:LI12:214:LVDTPROFILE") { field(DESC, "WS12214 Measured Profile") field(SCAN, "Passive") field(ALG, "Circular Buffer") field(NSAM, "200") field(INP, "WIRE:LI12:214:LVRAW PP") } record(subArray, "WIRE:LI12:214:SUBLPROF") { field(DESC, "WS12214 Distance Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI12:214:PLVDTPROFILE.VAL") } record(subArray, "WIRE:LI12:214:SUBMPROF") { field(DESC, "WS12214 Motion Region") field(SCAN, "Passive") field(MALM, "200") field(NELM, "200") field(INDX, "0") field(FTVL, "DOUBLE") field(INP, "WIRE:LI12:214:PMOTPROFILE.VAL") } record(waveform, "WIRE:LI12:214:PMOTPROFILE") { field(DESC, "WS12214 Prev Motion Profile") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI12:214:MOTPROFILE") field(FLNK, "WIRE:LI12:214:SUBMPROF") } record(waveform, "WIRE:LI12:214:PLVDTPROFILE") { field(DESC, "WS12214 Prev Measured Profl") field(SCAN, "Passive") field(FTVL, "DOUBLE") field(EGU, "microns") field(NELM, "200") field(INP, "WIRE:LI12:214:LVDTPROFILE") field(FLNK, "WIRE:LI12:214:SUBLPROF") } record(ai, "WIRE:LI12:214:MOTRVALREST") { field(INP, "WIRE:LI12:214:MOTR") } #! Further lines contain data used by VisualDCT #! View(0,0,0.5) #! Record("WIRE:LI12:214:MOTR",160,62,0,0,"WIRE:LI12:214:MOTR") #! Field("WIRE:LI12:214:MOTR.FLNK",16777215,1,"WIRE:LI12:214:MOTR.FLNK") #! Field("WIRE:LI12:214:MOTR.RDBL",16777215,1,"WIRE:LI12:214:MOTR.RDBL") #! Field("WIRE:LI12:214:MOTR.OFF",16777215,1,"WIRE:LI12:214:MOTR.OFF") #! Field("WIRE:LI12:214:MOTR.HLM",16777215,1,"WIRE:LI12:214:MOTR.HLM") #! Field("WIRE:LI12:214:MOTR.LLM",16777215,1,"WIRE:LI12:214:MOTR.LLM") #! Field("WIRE:LI12:214:MOTR.VELO",16777215,1,"WIRE:LI12:214:MOTR.VELO") #! Field("WIRE:LI12:214:MOTR.VAL",16777215,1,"WIRE:LI12:214:MOTR.VAL") #! Record("WIRE:LI12:214:POSN",1000,544,0,0,"WIRE:LI12:214:POSN") #! Field("WIRE:LI12:214:POSN.FLNK",16777215,1,"WIRE:LI12:214:POSN.FLNK") #! Field("WIRE:LI12:214:POSN.EOFF",16777215,0,"WIRE:LI12:214:POSN.EOFF") #! Field("WIRE:LI12:214:POSN.VAL",16777215,1,"WIRE:LI12:214:POSN.VAL") #! Record("WIRE:LI12:214:MASK",1340,1352,0,0,"WIRE:LI12:214:MASK") #! Field("WIRE:LI12:214:MASK.FLNK",16777215,1,"WIRE:LI12:214:MASK.FLNK") #! Record("WIRE:LI12:214:NEWOFFS",720,612,0,0,"WIRE:LI12:214:NEWOFFS") #! Field("WIRE:LI12:214:NEWOFFS.DOL",16777215,0,"WIRE:LI12:214:NEWOFFS.DOL") #! Link("WIRE:LI12:214:NEWOFFS.DOL","WIRE:LI12:214:MOTR.OFF") #! Field("WIRE:LI12:214:NEWOFFS.OUT",16777215,1,"WIRE:LI12:214:NEWOFFS.OUT") #! Link("WIRE:LI12:214:NEWOFFS.OUT","WIRE:LI12:214:POSN.EOFF") #! Record("WIRE:LI12:214:MOTRVAL",860,986,0,0,"WIRE:LI12:214:MOTRVAL") #! Field("WIRE:LI12:214:MOTRVAL.OUT",16777215,0,"WIRE:LI12:214:MOTRVAL.OUT") #! Link("WIRE:LI12:214:MOTRVAL.OUT","WIRE:LI12:214:MOTR.VAL") #! Field("WIRE:LI12:214:MOTRVAL.FLNK",16777215,0,"WIRE:LI12:214:MOTRVAL.FLNK") #! Link("WIRE:LI12:214:MOTRVAL.FLNK","WIRE:LI12:214:MOTR") #! Record("WIRE:LI12:214:MOTRHI",860,1238,0,0,"WIRE:LI12:214:MOTRHI") #! Field("WIRE:LI12:214:MOTRHI.DOL",16777215,0,"WIRE:LI12:214:MOTRHI.DOL") #! Link("WIRE:LI12:214:MOTRHI.DOL","WIRE:LI12:214:MOTR.HLM") #! Field("WIRE:LI12:214:MOTRHI.OUT",16777215,0,"WIRE:LI12:214:MOTRHI.OUT") #! Link("WIRE:LI12:214:MOTRHI.OUT","WIRE:LI12:214:MOTR.VAL") #! Field("WIRE:LI12:214:MOTRHI.FLNK",16777215,0,"WIRE:LI12:214:MOTRHI.FLNK") #! Link("WIRE:LI12:214:MOTRHI.FLNK","WIRE:LI12:214:MOTR") #! Record("WIRE:LI12:214:MOTRLO",860,1558,0,0,"WIRE:LI12:214:MOTRLO") #! Field("WIRE:LI12:214:MOTRLO.DOL",16777215,0,"WIRE:LI12:214:MOTRLO.DOL") #! Link("WIRE:LI12:214:MOTRLO.DOL","WIRE:LI12:214:MOTR.LLM") #! Field("WIRE:LI12:214:MOTRLO.OUT",16777215,0,"WIRE:LI12:214:MOTRLO.OUT") #! Link("WIRE:LI12:214:MOTRLO.OUT","WIRE:LI12:214:MOTR.VAL") #! Field("WIRE:LI12:214:MOTRLO.FLNK",16777215,0,"WIRE:LI12:214:MOTRLO.FLNK") #! Link("WIRE:LI12:214:MOTRLO.FLNK","WIRE:LI12:214:MOTR") #! Record("WIRE:LI12:214:MOTRVELCHOICE",840,1884,0,0,"WIRE:LI12:214:MOTRVELCHOICE") #! Field("WIRE:LI12:214:MOTRVELCHOICE.OUT",16777215,0,"WIRE:LI12:214:MOTRVELCHOICE.OUT") #! Link("WIRE:LI12:214:MOTRVELCHOICE.OUT","WIRE:LI12:214:MOTR.VELO") #! Record("WIRE:LI12:214:SYNCMOTPROFILE",1700,598,0,0,"WIRE:LI12:214:SYNCMOTPROFILE") #! Field("WIRE:LI12:214:SYNCMOTPROFILE.LNK1",16777215,0,"WIRE:LI12:214:SYNCMOTPROFILE.LNK1") #! Link("WIRE:LI12:214:SYNCMOTPROFILE.LNK1","WIRE:LI12:214:MOTPROFILE") #! Field("WIRE:LI12:214:SYNCMOTPROFILE.LNK2",16777215,1,"WIRE:LI12:214:SYNCMOTPROFILE.LNK2") #! Link("WIRE:LI12:214:SYNCMOTPROFILE.LNK2","WIRE:LI12:214:LVDTPROFILE") #! Field("WIRE:LI12:214:SYNCMOTPROFILE.LNK3",16777215,1,"WIRE:LI12:214:SYNCMOTPROFILE.LNK3") #! Link("WIRE:LI12:214:SYNCMOTPROFILE.LNK3","WIRE:LI12:214:CALIBSYNC") #! Record("WIRE:LI12:214:CALIBSYNC",1980,860,0,0,"WIRE:LI12:214:CALIBSYNC") #! Record("WIRE:LI12:214:MOTPROFILE",1380,706,0,1,"WIRE:LI12:214:MOTPROFILE") #! Field("WIRE:LI12:214:MOTPROFILE.INP",16777215,0,"WIRE:LI12:214:MOTPROFILE.INP") #! Link("WIRE:LI12:214:MOTPROFILE.INP","WIRE:LI12:214:POSN.VAL") #! Field("WIRE:LI12:214:MOTPROFILE.VAL",16777215,0,"WIRE:LI12:214:MOTPROFILE.VAL") #! Record("WIRE:LI12:214:LVDTPROFILE",2000,566,0,0,"WIRE:LI12:214:LVDTPROFILE") #! Field("WIRE:LI12:214:LVDTPROFILE.INP",16777215,1,"WIRE:LI12:214:LVDTPROFILE.INP") #! Field("WIRE:LI12:214:LVDTPROFILE.VAL",16777215,1,"WIRE:LI12:214:LVDTPROFILE.VAL") #! Record("WIRE:LI12:214:SUBLPROF",2560,698,0,0,"WIRE:LI12:214:SUBLPROF") #! Field("WIRE:LI12:214:SUBLPROF.INP",16777215,0,"WIRE:LI12:214:SUBLPROF.INP") #! Link("WIRE:LI12:214:SUBLPROF.INP","WIRE:LI12:214:PLVDTPROFILE.VAL") #! Record("WIRE:LI12:214:SUBMPROF",1700,1078,0,0,"WIRE:LI12:214:SUBMPROF") #! Field("WIRE:LI12:214:SUBMPROF.INP",16777215,0,"WIRE:LI12:214:SUBMPROF.INP") #! Link("WIRE:LI12:214:SUBMPROF.INP","WIRE:LI12:214:PMOTPROFILE.VAL") #! Record("WIRE:LI12:214:PMOTPROFILE",1380,998,0,0,"WIRE:LI12:214:PMOTPROFILE") #! Field("WIRE:LI12:214:PMOTPROFILE.FLNK",16777215,1,"WIRE:LI12:214:PMOTPROFILE.FLNK") #! Link("WIRE:LI12:214:PMOTPROFILE.FLNK","WIRE:LI12:214:SUBMPROF") #! Field("WIRE:LI12:214:PMOTPROFILE.VAL",16777215,1,"WIRE:LI12:214:PMOTPROFILE.VAL") #! Field("WIRE:LI12:214:PMOTPROFILE.INP",16777215,0,"WIRE:LI12:214:PMOTPROFILE.INP") #! Link("WIRE:LI12:214:PMOTPROFILE.INP","WIRE:LI12:214:MOTPROFILE.VAL") #! Record("WIRE:LI12:214:PLVDTPROFILE",2280,578,0,0,"WIRE:LI12:214:PLVDTPROFILE") #! Field("WIRE:LI12:214:PLVDTPROFILE.INP",16777215,0,"WIRE:LI12:214:PLVDTPROFILE.INP") #! Link("WIRE:LI12:214:PLVDTPROFILE.INP","WIRE:LI12:214:LVDTPROFILE.VAL") #! Field("WIRE:LI12:214:PLVDTPROFILE.FLNK",16777215,1,"WIRE:LI12:214:PLVDTPROFILE.FLNK") #! Link("WIRE:LI12:214:PLVDTPROFILE.FLNK","WIRE:LI12:214:SUBLPROF") #! Field("WIRE:LI12:214:PLVDTPROFILE.VAL",16777215,1,"WIRE:LI12:214:PLVDTPROFILE.VAL") #! Record("WIRE:LI12:214:MOTRVALREST",500,914,0,0,"WIRE:LI12:214:MOTRVALREST") #! Field("WIRE:LI12:214:MOTRVALREST.INP",16777215,0,"WIRE:LI12:214:MOTRVALREST.INP") #! Link("WIRE:LI12:214:MOTRVALREST.INP","WIRE:LI12:214:MOTR.VAL") record(bi,"WIRE:LI11:614:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI11:614:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI11:614:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI11:744:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI11:744:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI11:744:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI12:214:CORRECT") { field(DESC, "CORRECT Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI12:214:VERIFY") { field(DESC, "VERIFY Button") field(DTYP, "Soft Channel") field(OSV, "MINOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(bi,"WIRE:LI12:214:SETMODEALARM") { field(DESC, "Set Button Alarm") field(DTYP, "Soft Channel") field(OSV, "MAJOR") field(ZSV, "NO_ALARM") field(PINI, "YES") field(INP, "0") field(ZNAM, "OFF") field(ONAM, "On") } record(calcout, "WIRE:LI11:614:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI11:614:MOTR.RBV") field(INPB, "WIRE:LI11:614:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI11:614:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI11:614:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI11:744:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI11:744:MOTR.RBV") field(INPB, "WIRE:LI11:744:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI11:744:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI11:744:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI12:214:MOTRERROR") { field(DESC, "LVDT-MOTOR error calc") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A-B") field(INPA, "WIRE:LI12:214:MOTR.RBV") field(INPB, "WIRE:LI12:214:LVPOS") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } record(calcout, "WIRE:LI12:214:MOTRACTIVE") { field(DESC, "Motor In Use") field(SCAN, "1 second") field(DTYP, "Soft Channel") field(CALC, "A") field(INPA, "WIRE:LI12:214:MOTR.DMOV") field(HIGH, "200.0") field(LOW, "-200.0") field(HSV, "MINOR") field(LSV, "MINOR") field(PINI, "YES") info(autosaveFields, "LOW LOLO HIGH HIHI") } #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI11:614:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 0)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI11:614:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 0)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI11:614:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI11:614:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI11:614:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI11:614:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI11:614:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI11:614:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI11:614:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI11:614:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 0) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI11:614:POWER",20,14,0,0,"WIRE:LI11:614:POWER") #! Record("WIRE:LI11:614:BRAKE",260,14,0,0,"WIRE:LI11:614:BRAKE") #! Record("WIRE:LI11:614:POSN",500,5,0,0,"WIRE:LI11:614:POSN") #! Field("WIRE:LI11:614:POSN.FLNK",16777215,1,"WIRE:LI11:614:POSN.FLNK") #! Record("WIRE:LI11:614:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI11:614:FIRMWARE_VERSION") #! Record("WIRE:LI11:614:EN_POSN",980,28,0,0,"WIRE:LI11:614:EN_POSN") #! Record("WIRE:LI11:614:LOWLMT",1220,22,0,0,"WIRE:LI11:614:LOWLMT") #! Record("WIRE:LI11:614:HIGHLMT",1460,22,0,0,"WIRE:LI11:614:HIGHLMT") #! Record("WIRE:LI11:614:DONE",1700,22,0,0,"WIRE:LI11:614:DONE") #! Record("WIRE:LI11:614:HOMELMT",1940,22,0,0,"WIRE:LI11:614:HOMELMT") #! Record("WIRE:LI11:614:FAULT",2180,22,0,0,"WIRE:LI11:614:FAULT") #! Record("WIRE:LI11:614:HASENCODER",2420,22,0,0,"WIRE:LI11:614:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI11:744:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 1)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI11:744:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 1)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI11:744:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI11:744:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI11:744:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI11:744:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI11:744:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI11:744:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI11:744:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI11:744:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 1) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI11:744:POWER",20,14,0,0,"WIRE:LI11:744:POWER") #! Record("WIRE:LI11:744:BRAKE",260,14,0,0,"WIRE:LI11:744:BRAKE") #! Record("WIRE:LI11:744:POSN",500,5,0,0,"WIRE:LI11:744:POSN") #! Field("WIRE:LI11:744:POSN.FLNK",16777215,1,"WIRE:LI11:744:POSN.FLNK") #! Record("WIRE:LI11:744:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI11:744:FIRMWARE_VERSION") #! Record("WIRE:LI11:744:EN_POSN",980,28,0,0,"WIRE:LI11:744:EN_POSN") #! Record("WIRE:LI11:744:LOWLMT",1220,22,0,0,"WIRE:LI11:744:LOWLMT") #! Record("WIRE:LI11:744:HIGHLMT",1460,22,0,0,"WIRE:LI11:744:HIGHLMT") #! Record("WIRE:LI11:744:DONE",1700,22,0,0,"WIRE:LI11:744:DONE") #! Record("WIRE:LI11:744:HOMELMT",1940,22,0,0,"WIRE:LI11:744:HOMELMT") #! Record("WIRE:LI11:744:FAULT",2180,22,0,0,"WIRE:LI11:744:FAULT") #! Record("WIRE:LI11:744:HASENCODER",2420,22,0,0,"WIRE:LI11:744:HASENCODER") #! Generated by VisualDCT v2.6 #! DBDSTART #! DBDEND record(bo, "WIRE:LI12:214:POWER") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 2)HYTEC_POWER") field(VAL, "1") field(ZNAM, "On") field(ONAM, "Off") } record(bo, "WIRE:LI12:214:BRAKE") { field(DTYP, "asynInt32") field(OUT, "@asyn(Hy8601-01 2)HYTEC_BRAKE") field(VAL, "1") field(ZNAM, "Set") field(ONAM, "Rls") } record(ai, "WIRE:LI12:214:FIRMWARE_VERSION") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2)HYTEC_FWVERSION") field(SCAN, "1 second") } record(ai, "WIRE:LI12:214:EN_POSN") { field(PINI, "YES") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2)MOTOR_ENCODER_POSITION") field(SCAN, "1 second") } record(ai, "WIRE:LI12:214:LOWLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_LOW_LIMIT") } record(ai, "WIRE:LI12:214:HIGHLMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_HIGH_LIMIT") } record(ai, "WIRE:LI12:214:DONE") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_DONE") } record(ai, "WIRE:LI12:214:HOMELMT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_AT_HOME") } record(ai, "WIRE:LI12:214:FAULT") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_PROBLEM") } record(ai, "WIRE:LI12:214:HASENCODER") { field(SCAN, "I/O Intr") field(DTYP, "asynInt32") field(INP, "@asyn(Hy8601-01 2) MOTOR_STATUS_HAS_ENCODER") } #! Further lines contain data used by VisualDCT #! View(0,0,1.0) #! Record("WIRE:LI12:214:POWER",20,14,0,0,"WIRE:LI12:214:POWER") #! Record("WIRE:LI12:214:BRAKE",260,14,0,0,"WIRE:LI12:214:BRAKE") #! Record("WIRE:LI12:214:POSN",500,5,0,0,"WIRE:LI12:214:POSN") #! Field("WIRE:LI12:214:POSN.FLNK",16777215,1,"WIRE:LI12:214:POSN.FLNK") #! Record("WIRE:LI12:214:FIRMWARE_VERSION",740,28,0,0,"WIRE:LI12:214:FIRMWARE_VERSION") #! Record("WIRE:LI12:214:EN_POSN",980,28,0,0,"WIRE:LI12:214:EN_POSN") #! Record("WIRE:LI12:214:LOWLMT",1220,22,0,0,"WIRE:LI12:214:LOWLMT") #! Record("WIRE:LI12:214:HIGHLMT",1460,22,0,0,"WIRE:LI12:214:HIGHLMT") #! Record("WIRE:LI12:214:DONE",1700,22,0,0,"WIRE:LI12:214:DONE") #! Record("WIRE:LI12:214:HOMELMT",1940,22,0,0,"WIRE:LI12:214:HOMELMT") #! Record("WIRE:LI12:214:FAULT",2180,22,0,0,"WIRE:LI12:214:FAULT") #! Record("WIRE:LI12:214:HASENCODER",2420,22,0,0,"WIRE:LI12:214:HASENCODER")