#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:GUNB:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:GUNB:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:GUNB:1:CTRL CA PP")
  field(LNK2, "MGNT:GUNB:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:GUNB:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:GUNB:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:GUNB:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:GUNB:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:GUNB:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:GUNB:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:GUNB:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:GUNB:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:GUNB:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:GUNB:1:ALLSWITCH")
}

record(seq, "MGNT:GUNB:1:ALLSWITCH") {
  field(DOL1, "MGNT:GUNB:1:CTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:CTRL")
}

record(bo, "MGNT:GUNB:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLSTARGO")
}

record(fanout, "MGNT:GUNB:1:ALLSTARGO") {
  field(LNK1, "MGNT:GUNB:1:ALLBENDSGO")
  field(LNK2, "MGNT:GUNB:1:ALLBTRMSGO")
  field(LNK3, "MGNT:GUNB:1:ALLLGPSSGO")
  field(LNK4, "MGNT:GUNB:1:ALLQUADSGO")
  field(LNK5, "MGNT:GUNB:1:ALLXCORSGO")
  field(LNK6, "MGNT:GUNB:1:ALLYCORSGO")
  field(FLNK, "MGNT:GUNB:1:ALLSTARGO_2")
}
record(fanout, "MGNT:GUNB:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:GUNB:1:ALLSOLNSGO")
  field(LNK2, "MGNT:GUNB:1:ALLKICKSGO")
  field(LNK3, "MGNT:GUNB:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:GUNB:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:GUNB:1:BENDSWITCH")
}

record(seq, "MGNT:GUNB:1:BENDSWITCH") {
  field(DOL1, "MGNT:GUNB:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:BENDCTRL")
}

record(seq, "MGNT:GUNB:1:ALLBENDSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:BENDCTRL",20,10,0,0,"MGNT:GUNB:1:BENDCTRL")
#! Field("MGNT:GUNB:1:BENDCTRL.FLNK",16777215,1,"MGNT:GUNB:1:BENDCTRL.FLNK")
#! Link("MGNT:GUNB:1:BENDCTRL.FLNK","MGNT:GUNB:1:BENDSWITCH")
#! Field("MGNT:GUNB:1:BENDCTRL.FFVL",16777215,1,"MGNT:GUNB:1:BENDCTRL.FFVL")
#! Record("MGNT:GUNB:1:BENDSWITCH",460,322,0,0,"MGNT:GUNB:1:BENDSWITCH")
#! Field("MGNT:GUNB:1:BENDSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:BENDSWITCH.DOL1")
#! Link("MGNT:GUNB:1:BENDSWITCH.DOL1","MGNT:GUNB:1:BENDCTRL.FFVL")
#! Field("MGNT:GUNB:1:BENDSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:BENDSWITCH.LNK1")
#! Field("MGNT:GUNB:1:BENDSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:BENDSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLBENDSGO",240,96,0,0,"MGNT:GUNB:1:ALLBENDSGO")
#! Field("MGNT:GUNB:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLBENDSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLBENDSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLBENDSGO.LNK1","MGNT:GUNB:1:ALLBENDS.VAL")
#! Record("MGNT:GUNB:1:ALLBENDS",540,102,0,0,"MGNT:GUNB:1:ALLBENDS")
#! Field("MGNT:GUNB:1:ALLBENDS.VAL",16777215,0,"MGNT:GUNB:1:ALLBENDS.VAL")
#! Field("MGNT:GUNB:1:ALLBENDS.FLNK",16777215,1,"MGNT:GUNB:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:GUNB:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:GUNB:1:BTRMSWITCH")
}

record(seq, "MGNT:GUNB:1:BTRMSWITCH") {
  field(DOL1, "MGNT:GUNB:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:BTRMCTRL")
}

record(seq, "MGNT:GUNB:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:BTRMCTRL",20,10,0,0,"MGNT:GUNB:1:BTRMCTRL")
#! Field("MGNT:GUNB:1:BTRMCTRL.FLNK",16777215,1,"MGNT:GUNB:1:BTRMCTRL.FLNK")
#! Link("MGNT:GUNB:1:BTRMCTRL.FLNK","MGNT:GUNB:1:BTRMSWITCH")
#! Field("MGNT:GUNB:1:BTRMCTRL.FFVL",16777215,1,"MGNT:GUNB:1:BTRMCTRL.FFVL")
#! Record("MGNT:GUNB:1:BTRMSWITCH",460,322,0,0,"MGNT:GUNB:1:BTRMSWITCH")
#! Field("MGNT:GUNB:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:BTRMSWITCH.DOL1")
#! Link("MGNT:GUNB:1:BTRMSWITCH.DOL1","MGNT:GUNB:1:BTRMCTRL.FFVL")
#! Field("MGNT:GUNB:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:BTRMSWITCH.LNK1")
#! Field("MGNT:GUNB:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:BTRMSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLBTRMSGO",240,96,0,0,"MGNT:GUNB:1:ALLBTRMSGO")
#! Field("MGNT:GUNB:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLBTRMSGO.LNK1","MGNT:GUNB:1:ALLBTRMS.VAL")
#! Record("MGNT:GUNB:1:ALLBTRMS",540,102,0,0,"MGNT:GUNB:1:ALLBTRMS")
#! Field("MGNT:GUNB:1:ALLBTRMS.VAL",16777215,0,"MGNT:GUNB:1:ALLBTRMS.VAL")
#! Field("MGNT:GUNB:1:ALLBTRMS.FLNK",16777215,1,"MGNT:GUNB:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:GUNB:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:GUNB:1:LGPSSWITCH")
}

record(seq, "MGNT:GUNB:1:LGPSSWITCH") {
  field(DOL1, "MGNT:GUNB:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:LGPSCTRL")
}

record(seq, "MGNT:GUNB:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:LGPSCTRL",20,10,0,0,"MGNT:GUNB:1:LGPSCTRL")
#! Field("MGNT:GUNB:1:LGPSCTRL.FLNK",16777215,1,"MGNT:GUNB:1:LGPSCTRL.FLNK")
#! Link("MGNT:GUNB:1:LGPSCTRL.FLNK","MGNT:GUNB:1:LGPSSWITCH")
#! Field("MGNT:GUNB:1:LGPSCTRL.FFVL",16777215,1,"MGNT:GUNB:1:LGPSCTRL.FFVL")
#! Record("MGNT:GUNB:1:LGPSSWITCH",460,322,0,0,"MGNT:GUNB:1:LGPSSWITCH")
#! Field("MGNT:GUNB:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:LGPSSWITCH.DOL1")
#! Link("MGNT:GUNB:1:LGPSSWITCH.DOL1","MGNT:GUNB:1:LGPSCTRL.FFVL")
#! Field("MGNT:GUNB:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:LGPSSWITCH.LNK1")
#! Field("MGNT:GUNB:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:LGPSSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLLGPSSGO",240,96,0,0,"MGNT:GUNB:1:ALLLGPSSGO")
#! Field("MGNT:GUNB:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLLGPSSGO.LNK1","MGNT:GUNB:1:ALLLGPSS.VAL")
#! Record("MGNT:GUNB:1:ALLLGPSS",540,102,0,0,"MGNT:GUNB:1:ALLLGPSS")
#! Field("MGNT:GUNB:1:ALLLGPSS.VAL",16777215,0,"MGNT:GUNB:1:ALLLGPSS.VAL")
#! Field("MGNT:GUNB:1:ALLLGPSS.FLNK",16777215,1,"MGNT:GUNB:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:GUNB:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:GUNB:1:QUADSWITCH")
}

record(seq, "MGNT:GUNB:1:QUADSWITCH") {
  field(DOL1, "MGNT:GUNB:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:QUADCTRL")
}

record(seq, "MGNT:GUNB:1:ALLQUADSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:QUADCTRL",20,10,0,0,"MGNT:GUNB:1:QUADCTRL")
#! Field("MGNT:GUNB:1:QUADCTRL.FLNK",16777215,1,"MGNT:GUNB:1:QUADCTRL.FLNK")
#! Link("MGNT:GUNB:1:QUADCTRL.FLNK","MGNT:GUNB:1:QUADSWITCH")
#! Field("MGNT:GUNB:1:QUADCTRL.FFVL",16777215,1,"MGNT:GUNB:1:QUADCTRL.FFVL")
#! Record("MGNT:GUNB:1:QUADSWITCH",460,322,0,0,"MGNT:GUNB:1:QUADSWITCH")
#! Field("MGNT:GUNB:1:QUADSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:QUADSWITCH.DOL1")
#! Link("MGNT:GUNB:1:QUADSWITCH.DOL1","MGNT:GUNB:1:QUADCTRL.FFVL")
#! Field("MGNT:GUNB:1:QUADSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:QUADSWITCH.LNK1")
#! Field("MGNT:GUNB:1:QUADSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:QUADSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLQUADSGO",240,96,0,0,"MGNT:GUNB:1:ALLQUADSGO")
#! Field("MGNT:GUNB:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLQUADSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLQUADSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLQUADSGO.LNK1","MGNT:GUNB:1:ALLQUADS.VAL")
#! Record("MGNT:GUNB:1:ALLQUADS",540,102,0,0,"MGNT:GUNB:1:ALLQUADS")
#! Field("MGNT:GUNB:1:ALLQUADS.VAL",16777215,0,"MGNT:GUNB:1:ALLQUADS.VAL")
#! Field("MGNT:GUNB:1:ALLQUADS.FLNK",16777215,1,"MGNT:GUNB:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:GUNB:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:GUNB:1:XCORSWITCH")
}

record(seq, "MGNT:GUNB:1:XCORSWITCH") {
  field(DOL1, "MGNT:GUNB:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:XCORCTRL")
}

record(seq, "MGNT:GUNB:1:ALLXCORSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:XCORCTRL",20,10,0,0,"MGNT:GUNB:1:XCORCTRL")
#! Field("MGNT:GUNB:1:XCORCTRL.FLNK",16777215,1,"MGNT:GUNB:1:XCORCTRL.FLNK")
#! Link("MGNT:GUNB:1:XCORCTRL.FLNK","MGNT:GUNB:1:XCORSWITCH")
#! Field("MGNT:GUNB:1:XCORCTRL.FFVL",16777215,1,"MGNT:GUNB:1:XCORCTRL.FFVL")
#! Record("MGNT:GUNB:1:XCORSWITCH",460,322,0,0,"MGNT:GUNB:1:XCORSWITCH")
#! Field("MGNT:GUNB:1:XCORSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:XCORSWITCH.DOL1")
#! Link("MGNT:GUNB:1:XCORSWITCH.DOL1","MGNT:GUNB:1:XCORCTRL.FFVL")
#! Field("MGNT:GUNB:1:XCORSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:XCORSWITCH.LNK1")
#! Field("MGNT:GUNB:1:XCORSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:XCORSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLXCORSGO",240,96,0,0,"MGNT:GUNB:1:ALLXCORSGO")
#! Field("MGNT:GUNB:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLXCORSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLXCORSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLXCORSGO.LNK1","MGNT:GUNB:1:ALLXCORS.VAL")
#! Record("MGNT:GUNB:1:ALLXCORS",540,102,0,0,"MGNT:GUNB:1:ALLXCORS")
#! Field("MGNT:GUNB:1:ALLXCORS.VAL",16777215,0,"MGNT:GUNB:1:ALLXCORS.VAL")
#! Field("MGNT:GUNB:1:ALLXCORS.FLNK",16777215,1,"MGNT:GUNB:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:GUNB:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:GUNB:1:YCORSWITCH")
}

record(seq, "MGNT:GUNB:1:YCORSWITCH") {
  field(DOL1, "MGNT:GUNB:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:YCORCTRL")
}

record(seq, "MGNT:GUNB:1:ALLYCORSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:YCORCTRL",20,10,0,0,"MGNT:GUNB:1:YCORCTRL")
#! Field("MGNT:GUNB:1:YCORCTRL.FLNK",16777215,1,"MGNT:GUNB:1:YCORCTRL.FLNK")
#! Link("MGNT:GUNB:1:YCORCTRL.FLNK","MGNT:GUNB:1:YCORSWITCH")
#! Field("MGNT:GUNB:1:YCORCTRL.FFVL",16777215,1,"MGNT:GUNB:1:YCORCTRL.FFVL")
#! Record("MGNT:GUNB:1:YCORSWITCH",460,322,0,0,"MGNT:GUNB:1:YCORSWITCH")
#! Field("MGNT:GUNB:1:YCORSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:YCORSWITCH.DOL1")
#! Link("MGNT:GUNB:1:YCORSWITCH.DOL1","MGNT:GUNB:1:YCORCTRL.FFVL")
#! Field("MGNT:GUNB:1:YCORSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:YCORSWITCH.LNK1")
#! Field("MGNT:GUNB:1:YCORSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:YCORSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLYCORSGO",240,96,0,0,"MGNT:GUNB:1:ALLYCORSGO")
#! Field("MGNT:GUNB:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLYCORSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLYCORSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLYCORSGO.LNK1","MGNT:GUNB:1:ALLYCORS.VAL")
#! Record("MGNT:GUNB:1:ALLYCORS",540,102,0,0,"MGNT:GUNB:1:ALLYCORS")
#! Field("MGNT:GUNB:1:ALLYCORS.VAL",16777215,0,"MGNT:GUNB:1:ALLYCORS.VAL")
#! Field("MGNT:GUNB:1:ALLYCORS.FLNK",16777215,1,"MGNT:GUNB:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:GUNB:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:GUNB:1:SOLNSWITCH")
}

record(seq, "MGNT:GUNB:1:SOLNSWITCH") {
  field(DOL1, "MGNT:GUNB:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:SOLNCTRL")
}

record(seq, "MGNT:GUNB:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:SOLNCTRL",20,10,0,0,"MGNT:GUNB:1:SOLNCTRL")
#! Field("MGNT:GUNB:1:SOLNCTRL.FLNK",16777215,1,"MGNT:GUNB:1:SOLNCTRL.FLNK")
#! Link("MGNT:GUNB:1:SOLNCTRL.FLNK","MGNT:GUNB:1:SOLNSWITCH")
#! Field("MGNT:GUNB:1:SOLNCTRL.FFVL",16777215,1,"MGNT:GUNB:1:SOLNCTRL.FFVL")
#! Record("MGNT:GUNB:1:SOLNSWITCH",460,322,0,0,"MGNT:GUNB:1:SOLNSWITCH")
#! Field("MGNT:GUNB:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:SOLNSWITCH.DOL1")
#! Link("MGNT:GUNB:1:SOLNSWITCH.DOL1","MGNT:GUNB:1:SOLNCTRL.FFVL")
#! Field("MGNT:GUNB:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:SOLNSWITCH.LNK1")
#! Field("MGNT:GUNB:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:SOLNSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLSOLNSGO",240,96,0,0,"MGNT:GUNB:1:ALLSOLNSGO")
#! Field("MGNT:GUNB:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLSOLNSGO.LNK1","MGNT:GUNB:1:ALLSOLNS.VAL")
#! Record("MGNT:GUNB:1:ALLSOLNS",540,102,0,0,"MGNT:GUNB:1:ALLSOLNS")
#! Field("MGNT:GUNB:1:ALLSOLNS.VAL",16777215,0,"MGNT:GUNB:1:ALLSOLNS.VAL")
#! Field("MGNT:GUNB:1:ALLSOLNS.FLNK",16777215,1,"MGNT:GUNB:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:GUNB:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:GUNB:1:KICKSWITCH")
}

record(seq, "MGNT:GUNB:1:KICKSWITCH") {
  field(DOL1, "MGNT:GUNB:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:KICKCTRL")
}

record(seq, "MGNT:GUNB:1:ALLKICKSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:KICKCTRL",20,10,0,0,"MGNT:GUNB:1:KICKCTRL")
#! Field("MGNT:GUNB:1:KICKCTRL.FLNK",16777215,1,"MGNT:GUNB:1:KICKCTRL.FLNK")
#! Link("MGNT:GUNB:1:KICKCTRL.FLNK","MGNT:GUNB:1:KICKSWITCH")
#! Field("MGNT:GUNB:1:KICKCTRL.FFVL",16777215,1,"MGNT:GUNB:1:KICKCTRL.FFVL")
#! Record("MGNT:GUNB:1:KICKSWITCH",460,322,0,0,"MGNT:GUNB:1:KICKSWITCH")
#! Field("MGNT:GUNB:1:KICKSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:KICKSWITCH.DOL1")
#! Link("MGNT:GUNB:1:KICKSWITCH.DOL1","MGNT:GUNB:1:KICKCTRL.FFVL")
#! Field("MGNT:GUNB:1:KICKSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:KICKSWITCH.LNK1")
#! Field("MGNT:GUNB:1:KICKSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:KICKSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLKICKSGO",240,96,0,0,"MGNT:GUNB:1:ALLKICKSGO")
#! Field("MGNT:GUNB:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLKICKSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLKICKSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLKICKSGO.LNK1","MGNT:GUNB:1:ALLKICKS.VAL")
#! Record("MGNT:GUNB:1:ALLKICKS",540,102,0,0,"MGNT:GUNB:1:ALLKICKS")
#! Field("MGNT:GUNB:1:ALLKICKS.VAL",16777215,0,"MGNT:GUNB:1:ALLKICKS.VAL")
#! Field("MGNT:GUNB:1:ALLKICKS.FLNK",16777215,1,"MGNT:GUNB:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:GUNB:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:GUNB:1:SEXTSWITCH")
}

record(seq, "MGNT:GUNB:1:SEXTSWITCH") {
  field(DOL1, "MGNT:GUNB:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:GUNB:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:GUNB:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:GUNB:1:SEXTCTRL")
}

record(seq, "MGNT:GUNB:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:GUNB:1:ALLSTAR")
  field(LNK1, "MGNT:GUNB:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:GUNB:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:GUNB:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:GUNB:1:SEXTCTRL",20,10,0,0,"MGNT:GUNB:1:SEXTCTRL")
#! Field("MGNT:GUNB:1:SEXTCTRL.FLNK",16777215,1,"MGNT:GUNB:1:SEXTCTRL.FLNK")
#! Link("MGNT:GUNB:1:SEXTCTRL.FLNK","MGNT:GUNB:1:SEXTSWITCH")
#! Field("MGNT:GUNB:1:SEXTCTRL.FFVL",16777215,1,"MGNT:GUNB:1:SEXTCTRL.FFVL")
#! Record("MGNT:GUNB:1:SEXTSWITCH",460,322,0,0,"MGNT:GUNB:1:SEXTSWITCH")
#! Field("MGNT:GUNB:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:GUNB:1:SEXTSWITCH.DOL1")
#! Link("MGNT:GUNB:1:SEXTSWITCH.DOL1","MGNT:GUNB:1:SEXTCTRL.FFVL")
#! Field("MGNT:GUNB:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:GUNB:1:SEXTSWITCH.LNK1")
#! Field("MGNT:GUNB:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:GUNB:1:SEXTSWITCH.FLNK")
#! Record("MGNT:GUNB:1:ALLSEXTSGO",240,96,0,0,"MGNT:GUNB:1:ALLSEXTSGO")
#! Field("MGNT:GUNB:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:GUNB:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:GUNB:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:GUNB:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:GUNB:1:ALLSEXTSGO.LNK1","MGNT:GUNB:1:ALLSEXTS.VAL")
#! Record("MGNT:GUNB:1:ALLSEXTS",540,102,0,0,"MGNT:GUNB:1:ALLSEXTS")
#! Field("MGNT:GUNB:1:ALLSEXTS.VAL",16777215,0,"MGNT:GUNB:1:ALLSEXTS.VAL")
#! Field("MGNT:GUNB:1:ALLSEXTS.FLNK",16777215,1,"MGNT:GUNB:1:ALLSEXTS.FLNK")
record(seq, "MGNT:GUNB:1:ALLKICKSSEL"){
}
record(seq, "MGNT:GUNB:1:ALLSEXTSSEL"){
}
record(seq, "MGNT:GUNB:1:ALLBENDSSEL"){
}
record(seq, "MGNT:GUNB:1:ALLBTRMSSEL"){
}

record(seq, "MGNT:GUNB:1:ALLLGPSSSEL"){
  field(DOL1, "MGNT:GUNB:1:ALLLGPSS")
  field(LNK1, "LGPS:GUNB:1:SELECT PP NMS")
}
record(seq, "MGNT:GUNB:1:ALLQUADSSEL"){
  field(DESC, "Select All QUADs")
  field(DOL1, "MGNT:GUNB:1:ALLQUADS")
  field(DOL2, "MGNT:GUNB:1:ALLQUADS")
  field(DOL3, "MGNT:GUNB:1:ALLQUADS")
  field(DOL4, "MGNT:GUNB:1:ALLQUADS")
  field(LNK1, "QUAD:GUNB:212:1:SELECT PP NMS")
  field(LNK2, "QUAD:GUNB:212:2:SELECT PP NMS")
  field(LNK3, "QUAD:GUNB:823:1:SELECT PP NMS")
  field(LNK4, "QUAD:GUNB:823:2:SELECT PP NMS")
}
record(seq, "MGNT:GUNB:1:ALLXCORSSEL"){
  field(DOL1, "MGNT:GUNB:1:ALLXCORS")
  field(DOL2, "MGNT:GUNB:1:ALLXCORS")
  field(DOL3, "MGNT:GUNB:1:ALLXCORS")
  field(DOL4, "MGNT:GUNB:1:ALLXCORS")
  field(DOL5, "MGNT:GUNB:1:ALLXCORS")
  field(LNK1, "XCOR:GUNB:293:SELECT PP NMS")
  field(LNK2, "XCOR:GUNB:388:SELECT PP NMS")
  field(LNK3, "XCOR:GUNB:513:SELECT PP NMS")
  field(LNK4, "XCOR:GUNB:713:SELECT PP NMS")
  field(LNK5, "XCOR:GUNB:927:SELECT PP NMS")
}
record(seq, "MGNT:GUNB:1:ALLYCORSSEL"){
  field(DOL1, "MGNT:GUNB:1:ALLYCORS")
  field(DOL2, "MGNT:GUNB:1:ALLYCORS")
  field(DOL3, "MGNT:GUNB:1:ALLYCORS")
  field(DOL4, "MGNT:GUNB:1:ALLYCORS")
  field(DOL5, "MGNT:GUNB:1:ALLYCORS")
  field(LNK1, "YCOR:GUNB:293:SELECT PP NMS")
  field(LNK2, "YCOR:GUNB:388:SELECT PP NMS")
  field(LNK3, "YCOR:GUNB:513:SELECT PP NMS")
  field(LNK4, "YCOR:GUNB:713:SELECT PP NMS")
  field(LNK5, "YCOR:GUNB:927:SELECT PP NMS")
}
record(seq, "MGNT:GUNB:1:ALLSOLNSSEL"){
  field(DOL1, "MGNT:GUNB:1:ALLSOLNS")
  field(DOL2, "MGNT:GUNB:1:ALLSOLNS")
  field(DOL3, "MGNT:GUNB:1:ALLSOLNS")
  field(LNK1, "SOLN:GUNB:100:SELECT PP NMS")
  field(LNK2, "SOLN:GUNB:212:SELECT PP NMS")
  field(LNK3, "SOLN:GUNB:823:SELECT PP NMS")
}

record(seq, "MGNT:GUNB:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func0")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:GUNB:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:GUNB:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:GUNB:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:GUNB:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:GUNB:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:GUNB:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:GUNB:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:GUNB:1:ALLFUNCGO2")
}
record(seq, "MGNT:GUNB:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func1")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:GUNB:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:GUNB:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:GUNB:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:GUNB:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}

record(fanout, "MGNT:GUNB:1:SOLNFUNCGO") {
  field(DESC, "Process All SOLNs")
  field(LNK1, "SOLN:GUNB:100:ALLFUNCGO")
  field(LNK2, "SOLN:GUNB:212:ALLFUNCGO")
  field(LNK3, "SOLN:GUNB:823:ALLFUNCGO")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:KICKFUNCGO") {
  field(DESC, "Process All KICKs")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:SEXTFUNCGO") {
  field(DESC, "Process All SEXTs")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:BENDFUNCGO") {
  field(DESC, "Process All BENDs")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:BTRMFUNCGO"){
  field(DESC, "Process All BTRMs")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:QUADFUNCGO"){
  field(DESC, "Process All QUADs")
  field(LNK1, "QUAD:GUNB:212:1:ALLFUNCGO")
  field(LNK2, "QUAD:GUNB:212:2:ALLFUNCGO")
  field(LNK3, "QUAD:GUNB:823:1:ALLFUNCGO")
  field(LNK4, "QUAD:GUNB:823:2:ALLFUNCGO")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:XCORFUNCGO"){
  field(DESC, "Process All XCORs")
  field(LNK1, "XCOR:GUNB:293:ALLFUNCGO")
  field(LNK2, "XCOR:GUNB:388:ALLFUNCGO")
  field(LNK3, "XCOR:GUNB:513:ALLFUNCGO")
  field(LNK4, "XCOR:GUNB:713:ALLFUNCGO")
  field(LNK5, "XCOR:GUNB:927:ALLFUNCGO")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:YCORFUNCGO"){
  field(DESC, "Process All YCORs")
  field(LNK1, "YCOR:GUNB:293:ALLFUNCGO")
  field(LNK2, "YCOR:GUNB:388:ALLFUNCGO")
  field(LNK3, "YCOR:GUNB:513:ALLFUNCGO")
  field(LNK4, "YCOR:GUNB:713:ALLFUNCGO")
  field(LNK5, "YCOR:GUNB:927:ALLFUNCGO")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}
record(fanout, "MGNT:GUNB:1:LGPSFUNCGO"){
  field(DESC, "Process All LGPSs")
  field(LNK1, "LGPS:GUNB:1:ALLFUNCGO")
  field(FLNK, "MGNT:GUNB:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "SOLN:GUNB:100:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "SOLN:GUNB:100:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "SOLN:GUNB:100:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "SOLN:GUNB:100:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "SOLN:GUNB:100:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "SOLN:GUNB:100:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "SOLN:GUNB:100:EDES.PROC PP")
    field(LNK2, "SOLN:GUNB:100:EACT.PROC PP")
    field(LNK3, "SOLN:GUNB:100:EERR.DISA PP")
    field(LNK4, "SOLN:GUNB:100:ECON.PROC PP")
    field(LNK5, "SOLN:GUNB:100:BMAGX.PROC PP")
    field(LNK6, "SOLN:GUNB:100:BMAGY.PROC PP")
    field(LNK7, "SOLN:GUNB:100:BLEM.PROC PP")
    field(LNK8, "SOLN:GUNB:100:BMOD.PROC PP")
    field(LNK9, "SOLN:GUNB:100:EDESSAVE.PROC PP")
    field(LNKA, "SOLN:GUNB:100:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"SOLN:GUNB:100:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "SOLN:GUNB:100:BMAX")
  field(DOL2, "SOLN:GUNB:100:BMAX")
  field(DOL3, "SOLN:GUNB:100:BMAX")
  field(DOL4, "SOLN:GUNB:100:BMIN")
  field(DOL5, "SOLN:GUNB:100:BMIN")
  field(DOL6, "SOLN:GUNB:100:BMIN")
  field(LNK1, "SOLN:GUNB:100:BMAGX.HOPR")
  field(LNK2, "SOLN:GUNB:100:BMAGY.HOPR")
  field(LNK3, "SOLN:GUNB:100:BLEM.HOPR")
  field(LNK4, "SOLN:GUNB:100:BMAGX.LOPR PP")
  field(LNK5, "SOLN:GUNB:100:BMAGY.LOPR PP")
  field(LNK6, "SOLN:GUNB:100:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "SOLN:GUNB:100:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "SOLN:GUNB:100:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "SOLN:GUNB:100:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "SOLN:GUNB:100:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "SOLN:GUNB:100:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:100:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:100:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:GUNB:100:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:100:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:GUNB:100:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "SOLN:GUNB:100:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "SOLN:GUNB:100:EDES NPP MS")
  field(INPB, "SOLN:GUNB:100:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "SOLN:GUNB:212:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "SOLN:GUNB:212:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "SOLN:GUNB:212:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "SOLN:GUNB:212:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "SOLN:GUNB:212:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "SOLN:GUNB:212:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "SOLN:GUNB:212:EDES.PROC PP")
    field(LNK2, "SOLN:GUNB:212:EACT.PROC PP")
    field(LNK3, "SOLN:GUNB:212:EERR.DISA PP")
    field(LNK4, "SOLN:GUNB:212:ECON.PROC PP")
    field(LNK5, "SOLN:GUNB:212:BMAGX.PROC PP")
    field(LNK6, "SOLN:GUNB:212:BMAGY.PROC PP")
    field(LNK7, "SOLN:GUNB:212:BLEM.PROC PP")
    field(LNK8, "SOLN:GUNB:212:BMOD.PROC PP")
    field(LNK9, "SOLN:GUNB:212:EDESSAVE.PROC PP")
    field(LNKA, "SOLN:GUNB:212:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"SOLN:GUNB:212:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "SOLN:GUNB:212:BMAX")
  field(DOL2, "SOLN:GUNB:212:BMAX")
  field(DOL3, "SOLN:GUNB:212:BMAX")
  field(DOL4, "SOLN:GUNB:212:BMIN")
  field(DOL5, "SOLN:GUNB:212:BMIN")
  field(DOL6, "SOLN:GUNB:212:BMIN")
  field(LNK1, "SOLN:GUNB:212:BMAGX.HOPR")
  field(LNK2, "SOLN:GUNB:212:BMAGY.HOPR")
  field(LNK3, "SOLN:GUNB:212:BLEM.HOPR")
  field(LNK4, "SOLN:GUNB:212:BMAGX.LOPR PP")
  field(LNK5, "SOLN:GUNB:212:BMAGY.LOPR PP")
  field(LNK6, "SOLN:GUNB:212:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "SOLN:GUNB:212:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "SOLN:GUNB:212:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "SOLN:GUNB:212:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "SOLN:GUNB:212:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "SOLN:GUNB:212:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:212:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:212:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:GUNB:212:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:212:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:GUNB:212:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "SOLN:GUNB:212:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "SOLN:GUNB:212:EDES NPP MS")
  field(INPB, "SOLN:GUNB:212:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "SOLN:GUNB:823:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "SOLN:GUNB:823:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "SOLN:GUNB:823:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "SOLN:GUNB:823:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "SOLN:GUNB:823:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "SOLN:GUNB:823:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "SOLN:GUNB:823:EDES.PROC PP")
    field(LNK2, "SOLN:GUNB:823:EACT.PROC PP")
    field(LNK3, "SOLN:GUNB:823:EERR.DISA PP")
    field(LNK4, "SOLN:GUNB:823:ECON.PROC PP")
    field(LNK5, "SOLN:GUNB:823:BMAGX.PROC PP")
    field(LNK6, "SOLN:GUNB:823:BMAGY.PROC PP")
    field(LNK7, "SOLN:GUNB:823:BLEM.PROC PP")
    field(LNK8, "SOLN:GUNB:823:BMOD.PROC PP")
    field(LNK9, "SOLN:GUNB:823:EDESSAVE.PROC PP")
    field(LNKA, "SOLN:GUNB:823:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"SOLN:GUNB:823:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "SOLN:GUNB:823:BMAX")
  field(DOL2, "SOLN:GUNB:823:BMAX")
  field(DOL3, "SOLN:GUNB:823:BMAX")
  field(DOL4, "SOLN:GUNB:823:BMIN")
  field(DOL5, "SOLN:GUNB:823:BMIN")
  field(DOL6, "SOLN:GUNB:823:BMIN")
  field(LNK1, "SOLN:GUNB:823:BMAGX.HOPR")
  field(LNK2, "SOLN:GUNB:823:BMAGY.HOPR")
  field(LNK3, "SOLN:GUNB:823:BLEM.HOPR")
  field(LNK4, "SOLN:GUNB:823:BMAGX.LOPR PP")
  field(LNK5, "SOLN:GUNB:823:BMAGY.LOPR PP")
  field(LNK6, "SOLN:GUNB:823:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "SOLN:GUNB:823:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "SOLN:GUNB:823:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "SOLN:GUNB:823:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "SOLN:GUNB:823:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "SOLN:GUNB:823:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:823:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:823:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:GUNB:823:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "SOLN:GUNB:823:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "SOLN:GUNB:823:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "SOLN:GUNB:823:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "SOLN:GUNB:823:EDES NPP MS")
  field(INPB, "SOLN:GUNB:823:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:GUNB:212:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:GUNB:212:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:GUNB:212:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:GUNB:212:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:GUNB:212:1:EDES.PROC PP")
    field(LNK2, "QUAD:GUNB:212:1:EACT.PROC PP")
    field(LNK3, "QUAD:GUNB:212:1:EERR.DISA PP")
    field(LNK4, "QUAD:GUNB:212:1:ECON.PROC PP")
    field(LNK5, "QUAD:GUNB:212:1:BMAGX.PROC PP")
    field(LNK6, "QUAD:GUNB:212:1:BMAGY.PROC PP")
    field(LNK7, "QUAD:GUNB:212:1:BLEM.PROC PP")
    field(LNK8, "QUAD:GUNB:212:1:BMOD.PROC PP")
    field(LNK9, "QUAD:GUNB:212:1:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:GUNB:212:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:GUNB:212:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:GUNB:212:1:BMAX")
  field(DOL2, "QUAD:GUNB:212:1:BMAX")
  field(DOL3, "QUAD:GUNB:212:1:BMAX")
  field(DOL4, "QUAD:GUNB:212:1:BMIN")
  field(DOL5, "QUAD:GUNB:212:1:BMIN")
  field(DOL6, "QUAD:GUNB:212:1:BMIN")
  field(LNK1, "QUAD:GUNB:212:1:BMAGX.HOPR")
  field(LNK2, "QUAD:GUNB:212:1:BMAGY.HOPR")
  field(LNK3, "QUAD:GUNB:212:1:BLEM.HOPR")
  field(LNK4, "QUAD:GUNB:212:1:BMAGX.LOPR PP")
  field(LNK5, "QUAD:GUNB:212:1:BMAGY.LOPR PP")
  field(LNK6, "QUAD:GUNB:212:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:212:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:212:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:GUNB:212:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:GUNB:212:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:GUNB:212:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:212:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:212:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:212:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:212:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:212:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:GUNB:212:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:GUNB:212:1:EDES NPP MS")
  field(INPB, "QUAD:GUNB:212:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:GUNB:212:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:GUNB:212:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:GUNB:212:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:GUNB:212:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:GUNB:212:2:EDES.PROC PP")
    field(LNK2, "QUAD:GUNB:212:2:EACT.PROC PP")
    field(LNK3, "QUAD:GUNB:212:2:EERR.DISA PP")
    field(LNK4, "QUAD:GUNB:212:2:ECON.PROC PP")
    field(LNK5, "QUAD:GUNB:212:2:BMAGX.PROC PP")
    field(LNK6, "QUAD:GUNB:212:2:BMAGY.PROC PP")
    field(LNK7, "QUAD:GUNB:212:2:BLEM.PROC PP")
    field(LNK8, "QUAD:GUNB:212:2:BMOD.PROC PP")
    field(LNK9, "QUAD:GUNB:212:2:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:GUNB:212:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:GUNB:212:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:GUNB:212:2:BMAX")
  field(DOL2, "QUAD:GUNB:212:2:BMAX")
  field(DOL3, "QUAD:GUNB:212:2:BMAX")
  field(DOL4, "QUAD:GUNB:212:2:BMIN")
  field(DOL5, "QUAD:GUNB:212:2:BMIN")
  field(DOL6, "QUAD:GUNB:212:2:BMIN")
  field(LNK1, "QUAD:GUNB:212:2:BMAGX.HOPR")
  field(LNK2, "QUAD:GUNB:212:2:BMAGY.HOPR")
  field(LNK3, "QUAD:GUNB:212:2:BLEM.HOPR")
  field(LNK4, "QUAD:GUNB:212:2:BMAGX.LOPR PP")
  field(LNK5, "QUAD:GUNB:212:2:BMAGY.LOPR PP")
  field(LNK6, "QUAD:GUNB:212:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:212:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:212:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:GUNB:212:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:GUNB:212:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:GUNB:212:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:212:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:212:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:212:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:212:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:212:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:GUNB:212:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:GUNB:212:2:EDES NPP MS")
  field(INPB, "QUAD:GUNB:212:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:GUNB:823:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:GUNB:823:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:GUNB:823:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:GUNB:823:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:GUNB:823:1:EDES.PROC PP")
    field(LNK2, "QUAD:GUNB:823:1:EACT.PROC PP")
    field(LNK3, "QUAD:GUNB:823:1:EERR.DISA PP")
    field(LNK4, "QUAD:GUNB:823:1:ECON.PROC PP")
    field(LNK5, "QUAD:GUNB:823:1:BMAGX.PROC PP")
    field(LNK6, "QUAD:GUNB:823:1:BMAGY.PROC PP")
    field(LNK7, "QUAD:GUNB:823:1:BLEM.PROC PP")
    field(LNK8, "QUAD:GUNB:823:1:BMOD.PROC PP")
    field(LNK9, "QUAD:GUNB:823:1:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:GUNB:823:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:GUNB:823:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:GUNB:823:1:BMAX")
  field(DOL2, "QUAD:GUNB:823:1:BMAX")
  field(DOL3, "QUAD:GUNB:823:1:BMAX")
  field(DOL4, "QUAD:GUNB:823:1:BMIN")
  field(DOL5, "QUAD:GUNB:823:1:BMIN")
  field(DOL6, "QUAD:GUNB:823:1:BMIN")
  field(LNK1, "QUAD:GUNB:823:1:BMAGX.HOPR")
  field(LNK2, "QUAD:GUNB:823:1:BMAGY.HOPR")
  field(LNK3, "QUAD:GUNB:823:1:BLEM.HOPR")
  field(LNK4, "QUAD:GUNB:823:1:BMAGX.LOPR PP")
  field(LNK5, "QUAD:GUNB:823:1:BMAGY.LOPR PP")
  field(LNK6, "QUAD:GUNB:823:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:823:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:823:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:GUNB:823:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:GUNB:823:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:GUNB:823:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:823:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:823:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:823:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:823:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:823:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:GUNB:823:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:GUNB:823:1:EDES NPP MS")
  field(INPB, "QUAD:GUNB:823:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:GUNB:823:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:GUNB:823:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:GUNB:823:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:GUNB:823:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:GUNB:823:2:EDES.PROC PP")
    field(LNK2, "QUAD:GUNB:823:2:EACT.PROC PP")
    field(LNK3, "QUAD:GUNB:823:2:EERR.DISA PP")
    field(LNK4, "QUAD:GUNB:823:2:ECON.PROC PP")
    field(LNK5, "QUAD:GUNB:823:2:BMAGX.PROC PP")
    field(LNK6, "QUAD:GUNB:823:2:BMAGY.PROC PP")
    field(LNK7, "QUAD:GUNB:823:2:BLEM.PROC PP")
    field(LNK8, "QUAD:GUNB:823:2:BMOD.PROC PP")
    field(LNK9, "QUAD:GUNB:823:2:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:GUNB:823:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:GUNB:823:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:GUNB:823:2:BMAX")
  field(DOL2, "QUAD:GUNB:823:2:BMAX")
  field(DOL3, "QUAD:GUNB:823:2:BMAX")
  field(DOL4, "QUAD:GUNB:823:2:BMIN")
  field(DOL5, "QUAD:GUNB:823:2:BMIN")
  field(DOL6, "QUAD:GUNB:823:2:BMIN")
  field(LNK1, "QUAD:GUNB:823:2:BMAGX.HOPR")
  field(LNK2, "QUAD:GUNB:823:2:BMAGY.HOPR")
  field(LNK3, "QUAD:GUNB:823:2:BLEM.HOPR")
  field(LNK4, "QUAD:GUNB:823:2:BMAGX.LOPR PP")
  field(LNK5, "QUAD:GUNB:823:2:BMAGY.LOPR PP")
  field(LNK6, "QUAD:GUNB:823:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:823:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:GUNB:823:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:GUNB:823:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:GUNB:823:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:GUNB:823:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:823:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:823:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:823:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:GUNB:823:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:GUNB:823:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:GUNB:823:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:GUNB:823:2:EDES NPP MS")
  field(INPB, "QUAD:GUNB:823:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:GUNB:293:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:GUNB:293:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:GUNB:293:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:GUNB:293:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:GUNB:293:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:GUNB:293:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:GUNB:293:EDES.PROC PP")
    field(LNK2, "XCOR:GUNB:293:EACT.PROC PP")
    field(LNK3, "XCOR:GUNB:293:EERR.DISA PP")
    field(LNK4, "XCOR:GUNB:293:ECON.PROC PP")
    field(LNK5, "XCOR:GUNB:293:BMAGX.PROC PP")
    field(LNK6, "XCOR:GUNB:293:BMAGY.PROC PP")
    field(LNK7, "XCOR:GUNB:293:BLEM.PROC PP")
    field(LNK8, "XCOR:GUNB:293:BMOD.PROC PP")
    field(LNK9, "XCOR:GUNB:293:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:GUNB:293:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:GUNB:293:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:GUNB:293:BMAX")
  field(DOL2, "XCOR:GUNB:293:BMAX")
  field(DOL3, "XCOR:GUNB:293:BMAX")
  field(DOL4, "XCOR:GUNB:293:BMIN")
  field(DOL5, "XCOR:GUNB:293:BMIN")
  field(DOL6, "XCOR:GUNB:293:BMIN")
  field(LNK1, "XCOR:GUNB:293:BMAGX.HOPR")
  field(LNK2, "XCOR:GUNB:293:BMAGY.HOPR")
  field(LNK3, "XCOR:GUNB:293:BLEM.HOPR")
  field(LNK4, "XCOR:GUNB:293:BMAGX.LOPR PP")
  field(LNK5, "XCOR:GUNB:293:BMAGY.LOPR PP")
  field(LNK6, "XCOR:GUNB:293:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:293:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:293:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:GUNB:293:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:GUNB:293:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:GUNB:293:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:293:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:293:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:293:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:293:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:293:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:GUNB:293:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:GUNB:293:EDES NPP MS")
  field(INPB, "XCOR:GUNB:293:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:GUNB:388:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:GUNB:388:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:GUNB:388:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:GUNB:388:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:GUNB:388:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:GUNB:388:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:GUNB:388:EDES.PROC PP")
    field(LNK2, "XCOR:GUNB:388:EACT.PROC PP")
    field(LNK3, "XCOR:GUNB:388:EERR.DISA PP")
    field(LNK4, "XCOR:GUNB:388:ECON.PROC PP")
    field(LNK5, "XCOR:GUNB:388:BMAGX.PROC PP")
    field(LNK6, "XCOR:GUNB:388:BMAGY.PROC PP")
    field(LNK7, "XCOR:GUNB:388:BLEM.PROC PP")
    field(LNK8, "XCOR:GUNB:388:BMOD.PROC PP")
    field(LNK9, "XCOR:GUNB:388:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:GUNB:388:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:GUNB:388:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:GUNB:388:BMAX")
  field(DOL2, "XCOR:GUNB:388:BMAX")
  field(DOL3, "XCOR:GUNB:388:BMAX")
  field(DOL4, "XCOR:GUNB:388:BMIN")
  field(DOL5, "XCOR:GUNB:388:BMIN")
  field(DOL6, "XCOR:GUNB:388:BMIN")
  field(LNK1, "XCOR:GUNB:388:BMAGX.HOPR")
  field(LNK2, "XCOR:GUNB:388:BMAGY.HOPR")
  field(LNK3, "XCOR:GUNB:388:BLEM.HOPR")
  field(LNK4, "XCOR:GUNB:388:BMAGX.LOPR PP")
  field(LNK5, "XCOR:GUNB:388:BMAGY.LOPR PP")
  field(LNK6, "XCOR:GUNB:388:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:388:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:388:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:GUNB:388:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:GUNB:388:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:GUNB:388:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:388:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:388:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:388:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:388:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:388:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:GUNB:388:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:GUNB:388:EDES NPP MS")
  field(INPB, "XCOR:GUNB:388:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:GUNB:513:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:GUNB:513:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:GUNB:513:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:GUNB:513:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:GUNB:513:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:GUNB:513:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:GUNB:513:EDES.PROC PP")
    field(LNK2, "XCOR:GUNB:513:EACT.PROC PP")
    field(LNK3, "XCOR:GUNB:513:EERR.DISA PP")
    field(LNK4, "XCOR:GUNB:513:ECON.PROC PP")
    field(LNK5, "XCOR:GUNB:513:BMAGX.PROC PP")
    field(LNK6, "XCOR:GUNB:513:BMAGY.PROC PP")
    field(LNK7, "XCOR:GUNB:513:BLEM.PROC PP")
    field(LNK8, "XCOR:GUNB:513:BMOD.PROC PP")
    field(LNK9, "XCOR:GUNB:513:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:GUNB:513:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:GUNB:513:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:GUNB:513:BMAX")
  field(DOL2, "XCOR:GUNB:513:BMAX")
  field(DOL3, "XCOR:GUNB:513:BMAX")
  field(DOL4, "XCOR:GUNB:513:BMIN")
  field(DOL5, "XCOR:GUNB:513:BMIN")
  field(DOL6, "XCOR:GUNB:513:BMIN")
  field(LNK1, "XCOR:GUNB:513:BMAGX.HOPR")
  field(LNK2, "XCOR:GUNB:513:BMAGY.HOPR")
  field(LNK3, "XCOR:GUNB:513:BLEM.HOPR")
  field(LNK4, "XCOR:GUNB:513:BMAGX.LOPR PP")
  field(LNK5, "XCOR:GUNB:513:BMAGY.LOPR PP")
  field(LNK6, "XCOR:GUNB:513:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:513:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:513:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:GUNB:513:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:GUNB:513:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:GUNB:513:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:513:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:513:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:513:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:513:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:513:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:GUNB:513:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:GUNB:513:EDES NPP MS")
  field(INPB, "XCOR:GUNB:513:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:GUNB:713:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:GUNB:713:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:GUNB:713:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:GUNB:713:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:GUNB:713:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:GUNB:713:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:GUNB:713:EDES.PROC PP")
    field(LNK2, "XCOR:GUNB:713:EACT.PROC PP")
    field(LNK3, "XCOR:GUNB:713:EERR.DISA PP")
    field(LNK4, "XCOR:GUNB:713:ECON.PROC PP")
    field(LNK5, "XCOR:GUNB:713:BMAGX.PROC PP")
    field(LNK6, "XCOR:GUNB:713:BMAGY.PROC PP")
    field(LNK7, "XCOR:GUNB:713:BLEM.PROC PP")
    field(LNK8, "XCOR:GUNB:713:BMOD.PROC PP")
    field(LNK9, "XCOR:GUNB:713:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:GUNB:713:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:GUNB:713:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:GUNB:713:BMAX")
  field(DOL2, "XCOR:GUNB:713:BMAX")
  field(DOL3, "XCOR:GUNB:713:BMAX")
  field(DOL4, "XCOR:GUNB:713:BMIN")
  field(DOL5, "XCOR:GUNB:713:BMIN")
  field(DOL6, "XCOR:GUNB:713:BMIN")
  field(LNK1, "XCOR:GUNB:713:BMAGX.HOPR")
  field(LNK2, "XCOR:GUNB:713:BMAGY.HOPR")
  field(LNK3, "XCOR:GUNB:713:BLEM.HOPR")
  field(LNK4, "XCOR:GUNB:713:BMAGX.LOPR PP")
  field(LNK5, "XCOR:GUNB:713:BMAGY.LOPR PP")
  field(LNK6, "XCOR:GUNB:713:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:713:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:713:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:GUNB:713:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:GUNB:713:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:GUNB:713:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:713:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:713:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:713:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:713:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:713:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:GUNB:713:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:GUNB:713:EDES NPP MS")
  field(INPB, "XCOR:GUNB:713:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:GUNB:927:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:GUNB:927:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:GUNB:927:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:GUNB:927:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:GUNB:927:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:GUNB:927:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:GUNB:927:EDES.PROC PP")
    field(LNK2, "XCOR:GUNB:927:EACT.PROC PP")
    field(LNK3, "XCOR:GUNB:927:EERR.DISA PP")
    field(LNK4, "XCOR:GUNB:927:ECON.PROC PP")
    field(LNK5, "XCOR:GUNB:927:BMAGX.PROC PP")
    field(LNK6, "XCOR:GUNB:927:BMAGY.PROC PP")
    field(LNK7, "XCOR:GUNB:927:BLEM.PROC PP")
    field(LNK8, "XCOR:GUNB:927:BMOD.PROC PP")
    field(LNK9, "XCOR:GUNB:927:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:GUNB:927:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:GUNB:927:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:GUNB:927:BMAX")
  field(DOL2, "XCOR:GUNB:927:BMAX")
  field(DOL3, "XCOR:GUNB:927:BMAX")
  field(DOL4, "XCOR:GUNB:927:BMIN")
  field(DOL5, "XCOR:GUNB:927:BMIN")
  field(DOL6, "XCOR:GUNB:927:BMIN")
  field(LNK1, "XCOR:GUNB:927:BMAGX.HOPR")
  field(LNK2, "XCOR:GUNB:927:BMAGY.HOPR")
  field(LNK3, "XCOR:GUNB:927:BLEM.HOPR")
  field(LNK4, "XCOR:GUNB:927:BMAGX.LOPR PP")
  field(LNK5, "XCOR:GUNB:927:BMAGY.LOPR PP")
  field(LNK6, "XCOR:GUNB:927:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:927:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:GUNB:927:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:GUNB:927:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:GUNB:927:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:GUNB:927:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:927:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:927:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:927:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:GUNB:927:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:GUNB:927:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:GUNB:927:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:GUNB:927:EDES NPP MS")
  field(INPB, "XCOR:GUNB:927:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:GUNB:293:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:GUNB:293:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:GUNB:293:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:GUNB:293:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:GUNB:293:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:GUNB:293:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:GUNB:293:EDES.PROC PP")
    field(LNK2, "YCOR:GUNB:293:EACT.PROC PP")
    field(LNK3, "YCOR:GUNB:293:EERR.DISA PP")
    field(LNK4, "YCOR:GUNB:293:ECON.PROC PP")
    field(LNK5, "YCOR:GUNB:293:BMAGX.PROC PP")
    field(LNK6, "YCOR:GUNB:293:BMAGY.PROC PP")
    field(LNK7, "YCOR:GUNB:293:BLEM.PROC PP")
    field(LNK8, "YCOR:GUNB:293:BMOD.PROC PP")
    field(LNK9, "YCOR:GUNB:293:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:GUNB:293:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:GUNB:293:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:GUNB:293:BMAX")
  field(DOL2, "YCOR:GUNB:293:BMAX")
  field(DOL3, "YCOR:GUNB:293:BMAX")
  field(DOL4, "YCOR:GUNB:293:BMIN")
  field(DOL5, "YCOR:GUNB:293:BMIN")
  field(DOL6, "YCOR:GUNB:293:BMIN")
  field(LNK1, "YCOR:GUNB:293:BMAGX.HOPR")
  field(LNK2, "YCOR:GUNB:293:BMAGY.HOPR")
  field(LNK3, "YCOR:GUNB:293:BLEM.HOPR")
  field(LNK4, "YCOR:GUNB:293:BMAGX.LOPR PP")
  field(LNK5, "YCOR:GUNB:293:BMAGY.LOPR PP")
  field(LNK6, "YCOR:GUNB:293:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:293:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:293:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:GUNB:293:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:GUNB:293:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:GUNB:293:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:293:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:293:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:293:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:293:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:293:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:GUNB:293:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:GUNB:293:EDES NPP MS")
  field(INPB, "YCOR:GUNB:293:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:GUNB:388:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:GUNB:388:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:GUNB:388:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:GUNB:388:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:GUNB:388:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:GUNB:388:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:GUNB:388:EDES.PROC PP")
    field(LNK2, "YCOR:GUNB:388:EACT.PROC PP")
    field(LNK3, "YCOR:GUNB:388:EERR.DISA PP")
    field(LNK4, "YCOR:GUNB:388:ECON.PROC PP")
    field(LNK5, "YCOR:GUNB:388:BMAGX.PROC PP")
    field(LNK6, "YCOR:GUNB:388:BMAGY.PROC PP")
    field(LNK7, "YCOR:GUNB:388:BLEM.PROC PP")
    field(LNK8, "YCOR:GUNB:388:BMOD.PROC PP")
    field(LNK9, "YCOR:GUNB:388:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:GUNB:388:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:GUNB:388:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:GUNB:388:BMAX")
  field(DOL2, "YCOR:GUNB:388:BMAX")
  field(DOL3, "YCOR:GUNB:388:BMAX")
  field(DOL4, "YCOR:GUNB:388:BMIN")
  field(DOL5, "YCOR:GUNB:388:BMIN")
  field(DOL6, "YCOR:GUNB:388:BMIN")
  field(LNK1, "YCOR:GUNB:388:BMAGX.HOPR")
  field(LNK2, "YCOR:GUNB:388:BMAGY.HOPR")
  field(LNK3, "YCOR:GUNB:388:BLEM.HOPR")
  field(LNK4, "YCOR:GUNB:388:BMAGX.LOPR PP")
  field(LNK5, "YCOR:GUNB:388:BMAGY.LOPR PP")
  field(LNK6, "YCOR:GUNB:388:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:388:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:388:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:GUNB:388:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:GUNB:388:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:GUNB:388:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:388:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:388:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:388:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:388:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:388:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:GUNB:388:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:GUNB:388:EDES NPP MS")
  field(INPB, "YCOR:GUNB:388:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:GUNB:513:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:GUNB:513:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:GUNB:513:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:GUNB:513:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:GUNB:513:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:GUNB:513:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:GUNB:513:EDES.PROC PP")
    field(LNK2, "YCOR:GUNB:513:EACT.PROC PP")
    field(LNK3, "YCOR:GUNB:513:EERR.DISA PP")
    field(LNK4, "YCOR:GUNB:513:ECON.PROC PP")
    field(LNK5, "YCOR:GUNB:513:BMAGX.PROC PP")
    field(LNK6, "YCOR:GUNB:513:BMAGY.PROC PP")
    field(LNK7, "YCOR:GUNB:513:BLEM.PROC PP")
    field(LNK8, "YCOR:GUNB:513:BMOD.PROC PP")
    field(LNK9, "YCOR:GUNB:513:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:GUNB:513:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:GUNB:513:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:GUNB:513:BMAX")
  field(DOL2, "YCOR:GUNB:513:BMAX")
  field(DOL3, "YCOR:GUNB:513:BMAX")
  field(DOL4, "YCOR:GUNB:513:BMIN")
  field(DOL5, "YCOR:GUNB:513:BMIN")
  field(DOL6, "YCOR:GUNB:513:BMIN")
  field(LNK1, "YCOR:GUNB:513:BMAGX.HOPR")
  field(LNK2, "YCOR:GUNB:513:BMAGY.HOPR")
  field(LNK3, "YCOR:GUNB:513:BLEM.HOPR")
  field(LNK4, "YCOR:GUNB:513:BMAGX.LOPR PP")
  field(LNK5, "YCOR:GUNB:513:BMAGY.LOPR PP")
  field(LNK6, "YCOR:GUNB:513:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:513:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:513:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:GUNB:513:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:GUNB:513:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:GUNB:513:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:513:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:513:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:513:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:513:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:513:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:GUNB:513:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:GUNB:513:EDES NPP MS")
  field(INPB, "YCOR:GUNB:513:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:GUNB:713:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:GUNB:713:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:GUNB:713:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:GUNB:713:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:GUNB:713:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:GUNB:713:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:GUNB:713:EDES.PROC PP")
    field(LNK2, "YCOR:GUNB:713:EACT.PROC PP")
    field(LNK3, "YCOR:GUNB:713:EERR.DISA PP")
    field(LNK4, "YCOR:GUNB:713:ECON.PROC PP")
    field(LNK5, "YCOR:GUNB:713:BMAGX.PROC PP")
    field(LNK6, "YCOR:GUNB:713:BMAGY.PROC PP")
    field(LNK7, "YCOR:GUNB:713:BLEM.PROC PP")
    field(LNK8, "YCOR:GUNB:713:BMOD.PROC PP")
    field(LNK9, "YCOR:GUNB:713:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:GUNB:713:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:GUNB:713:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:GUNB:713:BMAX")
  field(DOL2, "YCOR:GUNB:713:BMAX")
  field(DOL3, "YCOR:GUNB:713:BMAX")
  field(DOL4, "YCOR:GUNB:713:BMIN")
  field(DOL5, "YCOR:GUNB:713:BMIN")
  field(DOL6, "YCOR:GUNB:713:BMIN")
  field(LNK1, "YCOR:GUNB:713:BMAGX.HOPR")
  field(LNK2, "YCOR:GUNB:713:BMAGY.HOPR")
  field(LNK3, "YCOR:GUNB:713:BLEM.HOPR")
  field(LNK4, "YCOR:GUNB:713:BMAGX.LOPR PP")
  field(LNK5, "YCOR:GUNB:713:BMAGY.LOPR PP")
  field(LNK6, "YCOR:GUNB:713:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:713:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:713:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:GUNB:713:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:GUNB:713:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:GUNB:713:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:713:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:713:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:713:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:713:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:713:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:GUNB:713:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:GUNB:713:EDES NPP MS")
  field(INPB, "YCOR:GUNB:713:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:GUNB:927:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:GUNB:927:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:GUNB:927:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:GUNB:927:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:GUNB:927:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:GUNB:927:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:GUNB:927:EDES.PROC PP")
    field(LNK2, "YCOR:GUNB:927:EACT.PROC PP")
    field(LNK3, "YCOR:GUNB:927:EERR.DISA PP")
    field(LNK4, "YCOR:GUNB:927:ECON.PROC PP")
    field(LNK5, "YCOR:GUNB:927:BMAGX.PROC PP")
    field(LNK6, "YCOR:GUNB:927:BMAGY.PROC PP")
    field(LNK7, "YCOR:GUNB:927:BLEM.PROC PP")
    field(LNK8, "YCOR:GUNB:927:BMOD.PROC PP")
    field(LNK9, "YCOR:GUNB:927:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:GUNB:927:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:GUNB:927:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:GUNB:927:BMAX")
  field(DOL2, "YCOR:GUNB:927:BMAX")
  field(DOL3, "YCOR:GUNB:927:BMAX")
  field(DOL4, "YCOR:GUNB:927:BMIN")
  field(DOL5, "YCOR:GUNB:927:BMIN")
  field(DOL6, "YCOR:GUNB:927:BMIN")
  field(LNK1, "YCOR:GUNB:927:BMAGX.HOPR")
  field(LNK2, "YCOR:GUNB:927:BMAGY.HOPR")
  field(LNK3, "YCOR:GUNB:927:BLEM.HOPR")
  field(LNK4, "YCOR:GUNB:927:BMAGX.LOPR PP")
  field(LNK5, "YCOR:GUNB:927:BMAGY.LOPR PP")
  field(LNK6, "YCOR:GUNB:927:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:927:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:GUNB:927:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:GUNB:927:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:GUNB:927:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:GUNB:927:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:927:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:927:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:927:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:GUNB:927:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:GUNB:927:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:GUNB:927:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:GUNB:927:EDES NPP MS")
  field(INPB, "YCOR:GUNB:927:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:GUNB:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:GUNB:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:GUNB:1:CTRL.RVAL")
  field(LNK1, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL2, "MGNT:GUNB:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL3, "MGNT:GUNB:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL4, "MGNT:GUNB:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL5, "MGNT:GUNB:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL6, "MGNT:GUNB:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL7, "MGNT:GUNB:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL8, "MGNT:GUNB:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:GUNB:1:FUNC CA PP")
  field(DOL9, "MGNT:GUNB:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:GUNB:1:FUNC CA PP")
  field(DOLA, "MGNT:GUNB:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:GUNB:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:GUNB:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:GUNB:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:GUNB:1:EDES.PROC PP")
    field(LNK2, "LGPS:GUNB:1:EACT.PROC PP")
    field(LNK3, "LGPS:GUNB:1:EERR.DISA PP")
    field(LNK4, "LGPS:GUNB:1:ECON.PROC PP")
    field(LNK5, "LGPS:GUNB:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:GUNB:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:GUNB:1:BLEM.PROC PP")
    field(LNK8, "LGPS:GUNB:1:BMOD.PROC PP")
    field(LNK9, "LGPS:GUNB:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:GUNB:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:GUNB:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:GUNB:1:BMAX")
  field(DOL2, "LGPS:GUNB:1:BMAX")
  field(DOL3, "LGPS:GUNB:1:BMAX")
  field(DOL4, "LGPS:GUNB:1:BMIN")
  field(DOL5, "LGPS:GUNB:1:BMIN")
  field(DOL6, "LGPS:GUNB:1:BMIN")
  field(LNK1, "LGPS:GUNB:1:BMAGX.HOPR")
  field(LNK2, "LGPS:GUNB:1:BMAGY.HOPR")
  field(LNK3, "LGPS:GUNB:1:BLEM.HOPR")
  field(LNK4, "LGPS:GUNB:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:GUNB:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:GUNB:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:GUNB:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:GUNB:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:GUNB:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Volts")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:GUNB:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Volts")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:GUNB:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:GUNB:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:GUNB:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:GUNB:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:GUNB:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:GUNB:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:GUNB:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:GUNB:1:EDES NPP MS")
  field(INPB, "LGPS:GUNB:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:L0B:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:L0B:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:L0B:1:CTRL CA PP")
  field(LNK2, "MGNT:L0B:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:L0B:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:L0B:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:L0B:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:L0B:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:L0B:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:L0B:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:L0B:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:L0B:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:L0B:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:L0B:1:ALLSWITCH")
}

record(seq, "MGNT:L0B:1:ALLSWITCH") {
  field(DOL1, "MGNT:L0B:1:CTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:CTRL")
}

record(bo, "MGNT:L0B:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:L0B:1:ALLSTARGO")
}

record(fanout, "MGNT:L0B:1:ALLSTARGO") {
  field(LNK1, "MGNT:L0B:1:ALLBENDSGO")
  field(LNK2, "MGNT:L0B:1:ALLBTRMSGO")
  field(LNK3, "MGNT:L0B:1:ALLLGPSSGO")
  field(LNK4, "MGNT:L0B:1:ALLQUADSGO")
  field(LNK5, "MGNT:L0B:1:ALLXCORSGO")
  field(LNK6, "MGNT:L0B:1:ALLYCORSGO")
  field(FLNK, "MGNT:L0B:1:ALLSTARGO_2")
}
record(fanout, "MGNT:L0B:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:L0B:1:ALLSOLNSGO")
  field(LNK2, "MGNT:L0B:1:ALLKICKSGO")
  field(LNK3, "MGNT:L0B:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:L0B:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:L0B:1:BENDSWITCH")
}

record(seq, "MGNT:L0B:1:BENDSWITCH") {
  field(DOL1, "MGNT:L0B:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:BENDCTRL")
}

record(seq, "MGNT:L0B:1:ALLBENDSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:BENDCTRL",20,10,0,0,"MGNT:L0B:1:BENDCTRL")
#! Field("MGNT:L0B:1:BENDCTRL.FLNK",16777215,1,"MGNT:L0B:1:BENDCTRL.FLNK")
#! Link("MGNT:L0B:1:BENDCTRL.FLNK","MGNT:L0B:1:BENDSWITCH")
#! Field("MGNT:L0B:1:BENDCTRL.FFVL",16777215,1,"MGNT:L0B:1:BENDCTRL.FFVL")
#! Record("MGNT:L0B:1:BENDSWITCH",460,322,0,0,"MGNT:L0B:1:BENDSWITCH")
#! Field("MGNT:L0B:1:BENDSWITCH.DOL1",16777215,0,"MGNT:L0B:1:BENDSWITCH.DOL1")
#! Link("MGNT:L0B:1:BENDSWITCH.DOL1","MGNT:L0B:1:BENDCTRL.FFVL")
#! Field("MGNT:L0B:1:BENDSWITCH.LNK1",16777215,1,"MGNT:L0B:1:BENDSWITCH.LNK1")
#! Field("MGNT:L0B:1:BENDSWITCH.FLNK",16777215,1,"MGNT:L0B:1:BENDSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLBENDSGO",240,96,0,0,"MGNT:L0B:1:ALLBENDSGO")
#! Field("MGNT:L0B:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLBENDSGO.DOL1")
#! Field("MGNT:L0B:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLBENDSGO.LNK1")
#! Link("MGNT:L0B:1:ALLBENDSGO.LNK1","MGNT:L0B:1:ALLBENDS.VAL")
#! Record("MGNT:L0B:1:ALLBENDS",540,102,0,0,"MGNT:L0B:1:ALLBENDS")
#! Field("MGNT:L0B:1:ALLBENDS.VAL",16777215,0,"MGNT:L0B:1:ALLBENDS.VAL")
#! Field("MGNT:L0B:1:ALLBENDS.FLNK",16777215,1,"MGNT:L0B:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:L0B:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L0B:1:BTRMSWITCH")
}

record(seq, "MGNT:L0B:1:BTRMSWITCH") {
  field(DOL1, "MGNT:L0B:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:BTRMCTRL")
}

record(seq, "MGNT:L0B:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:BTRMCTRL",20,10,0,0,"MGNT:L0B:1:BTRMCTRL")
#! Field("MGNT:L0B:1:BTRMCTRL.FLNK",16777215,1,"MGNT:L0B:1:BTRMCTRL.FLNK")
#! Link("MGNT:L0B:1:BTRMCTRL.FLNK","MGNT:L0B:1:BTRMSWITCH")
#! Field("MGNT:L0B:1:BTRMCTRL.FFVL",16777215,1,"MGNT:L0B:1:BTRMCTRL.FFVL")
#! Record("MGNT:L0B:1:BTRMSWITCH",460,322,0,0,"MGNT:L0B:1:BTRMSWITCH")
#! Field("MGNT:L0B:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:L0B:1:BTRMSWITCH.DOL1")
#! Link("MGNT:L0B:1:BTRMSWITCH.DOL1","MGNT:L0B:1:BTRMCTRL.FFVL")
#! Field("MGNT:L0B:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:L0B:1:BTRMSWITCH.LNK1")
#! Field("MGNT:L0B:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:L0B:1:BTRMSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLBTRMSGO",240,96,0,0,"MGNT:L0B:1:ALLBTRMSGO")
#! Field("MGNT:L0B:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:L0B:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:L0B:1:ALLBTRMSGO.LNK1","MGNT:L0B:1:ALLBTRMS.VAL")
#! Record("MGNT:L0B:1:ALLBTRMS",540,102,0,0,"MGNT:L0B:1:ALLBTRMS")
#! Field("MGNT:L0B:1:ALLBTRMS.VAL",16777215,0,"MGNT:L0B:1:ALLBTRMS.VAL")
#! Field("MGNT:L0B:1:ALLBTRMS.FLNK",16777215,1,"MGNT:L0B:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:L0B:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L0B:1:LGPSSWITCH")
}

record(seq, "MGNT:L0B:1:LGPSSWITCH") {
  field(DOL1, "MGNT:L0B:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:LGPSCTRL")
}

record(seq, "MGNT:L0B:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:LGPSCTRL",20,10,0,0,"MGNT:L0B:1:LGPSCTRL")
#! Field("MGNT:L0B:1:LGPSCTRL.FLNK",16777215,1,"MGNT:L0B:1:LGPSCTRL.FLNK")
#! Link("MGNT:L0B:1:LGPSCTRL.FLNK","MGNT:L0B:1:LGPSSWITCH")
#! Field("MGNT:L0B:1:LGPSCTRL.FFVL",16777215,1,"MGNT:L0B:1:LGPSCTRL.FFVL")
#! Record("MGNT:L0B:1:LGPSSWITCH",460,322,0,0,"MGNT:L0B:1:LGPSSWITCH")
#! Field("MGNT:L0B:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:L0B:1:LGPSSWITCH.DOL1")
#! Link("MGNT:L0B:1:LGPSSWITCH.DOL1","MGNT:L0B:1:LGPSCTRL.FFVL")
#! Field("MGNT:L0B:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:L0B:1:LGPSSWITCH.LNK1")
#! Field("MGNT:L0B:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:L0B:1:LGPSSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLLGPSSGO",240,96,0,0,"MGNT:L0B:1:ALLLGPSSGO")
#! Field("MGNT:L0B:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:L0B:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:L0B:1:ALLLGPSSGO.LNK1","MGNT:L0B:1:ALLLGPSS.VAL")
#! Record("MGNT:L0B:1:ALLLGPSS",540,102,0,0,"MGNT:L0B:1:ALLLGPSS")
#! Field("MGNT:L0B:1:ALLLGPSS.VAL",16777215,0,"MGNT:L0B:1:ALLLGPSS.VAL")
#! Field("MGNT:L0B:1:ALLLGPSS.FLNK",16777215,1,"MGNT:L0B:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:L0B:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:L0B:1:QUADSWITCH")
}

record(seq, "MGNT:L0B:1:QUADSWITCH") {
  field(DOL1, "MGNT:L0B:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:QUADCTRL")
}

record(seq, "MGNT:L0B:1:ALLQUADSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:QUADCTRL",20,10,0,0,"MGNT:L0B:1:QUADCTRL")
#! Field("MGNT:L0B:1:QUADCTRL.FLNK",16777215,1,"MGNT:L0B:1:QUADCTRL.FLNK")
#! Link("MGNT:L0B:1:QUADCTRL.FLNK","MGNT:L0B:1:QUADSWITCH")
#! Field("MGNT:L0B:1:QUADCTRL.FFVL",16777215,1,"MGNT:L0B:1:QUADCTRL.FFVL")
#! Record("MGNT:L0B:1:QUADSWITCH",460,322,0,0,"MGNT:L0B:1:QUADSWITCH")
#! Field("MGNT:L0B:1:QUADSWITCH.DOL1",16777215,0,"MGNT:L0B:1:QUADSWITCH.DOL1")
#! Link("MGNT:L0B:1:QUADSWITCH.DOL1","MGNT:L0B:1:QUADCTRL.FFVL")
#! Field("MGNT:L0B:1:QUADSWITCH.LNK1",16777215,1,"MGNT:L0B:1:QUADSWITCH.LNK1")
#! Field("MGNT:L0B:1:QUADSWITCH.FLNK",16777215,1,"MGNT:L0B:1:QUADSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLQUADSGO",240,96,0,0,"MGNT:L0B:1:ALLQUADSGO")
#! Field("MGNT:L0B:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLQUADSGO.DOL1")
#! Field("MGNT:L0B:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLQUADSGO.LNK1")
#! Link("MGNT:L0B:1:ALLQUADSGO.LNK1","MGNT:L0B:1:ALLQUADS.VAL")
#! Record("MGNT:L0B:1:ALLQUADS",540,102,0,0,"MGNT:L0B:1:ALLQUADS")
#! Field("MGNT:L0B:1:ALLQUADS.VAL",16777215,0,"MGNT:L0B:1:ALLQUADS.VAL")
#! Field("MGNT:L0B:1:ALLQUADS.FLNK",16777215,1,"MGNT:L0B:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:L0B:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:L0B:1:XCORSWITCH")
}

record(seq, "MGNT:L0B:1:XCORSWITCH") {
  field(DOL1, "MGNT:L0B:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:XCORCTRL")
}

record(seq, "MGNT:L0B:1:ALLXCORSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:XCORCTRL",20,10,0,0,"MGNT:L0B:1:XCORCTRL")
#! Field("MGNT:L0B:1:XCORCTRL.FLNK",16777215,1,"MGNT:L0B:1:XCORCTRL.FLNK")
#! Link("MGNT:L0B:1:XCORCTRL.FLNK","MGNT:L0B:1:XCORSWITCH")
#! Field("MGNT:L0B:1:XCORCTRL.FFVL",16777215,1,"MGNT:L0B:1:XCORCTRL.FFVL")
#! Record("MGNT:L0B:1:XCORSWITCH",460,322,0,0,"MGNT:L0B:1:XCORSWITCH")
#! Field("MGNT:L0B:1:XCORSWITCH.DOL1",16777215,0,"MGNT:L0B:1:XCORSWITCH.DOL1")
#! Link("MGNT:L0B:1:XCORSWITCH.DOL1","MGNT:L0B:1:XCORCTRL.FFVL")
#! Field("MGNT:L0B:1:XCORSWITCH.LNK1",16777215,1,"MGNT:L0B:1:XCORSWITCH.LNK1")
#! Field("MGNT:L0B:1:XCORSWITCH.FLNK",16777215,1,"MGNT:L0B:1:XCORSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLXCORSGO",240,96,0,0,"MGNT:L0B:1:ALLXCORSGO")
#! Field("MGNT:L0B:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLXCORSGO.DOL1")
#! Field("MGNT:L0B:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLXCORSGO.LNK1")
#! Link("MGNT:L0B:1:ALLXCORSGO.LNK1","MGNT:L0B:1:ALLXCORS.VAL")
#! Record("MGNT:L0B:1:ALLXCORS",540,102,0,0,"MGNT:L0B:1:ALLXCORS")
#! Field("MGNT:L0B:1:ALLXCORS.VAL",16777215,0,"MGNT:L0B:1:ALLXCORS.VAL")
#! Field("MGNT:L0B:1:ALLXCORS.FLNK",16777215,1,"MGNT:L0B:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:L0B:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:L0B:1:YCORSWITCH")
}

record(seq, "MGNT:L0B:1:YCORSWITCH") {
  field(DOL1, "MGNT:L0B:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:YCORCTRL")
}

record(seq, "MGNT:L0B:1:ALLYCORSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:YCORCTRL",20,10,0,0,"MGNT:L0B:1:YCORCTRL")
#! Field("MGNT:L0B:1:YCORCTRL.FLNK",16777215,1,"MGNT:L0B:1:YCORCTRL.FLNK")
#! Link("MGNT:L0B:1:YCORCTRL.FLNK","MGNT:L0B:1:YCORSWITCH")
#! Field("MGNT:L0B:1:YCORCTRL.FFVL",16777215,1,"MGNT:L0B:1:YCORCTRL.FFVL")
#! Record("MGNT:L0B:1:YCORSWITCH",460,322,0,0,"MGNT:L0B:1:YCORSWITCH")
#! Field("MGNT:L0B:1:YCORSWITCH.DOL1",16777215,0,"MGNT:L0B:1:YCORSWITCH.DOL1")
#! Link("MGNT:L0B:1:YCORSWITCH.DOL1","MGNT:L0B:1:YCORCTRL.FFVL")
#! Field("MGNT:L0B:1:YCORSWITCH.LNK1",16777215,1,"MGNT:L0B:1:YCORSWITCH.LNK1")
#! Field("MGNT:L0B:1:YCORSWITCH.FLNK",16777215,1,"MGNT:L0B:1:YCORSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLYCORSGO",240,96,0,0,"MGNT:L0B:1:ALLYCORSGO")
#! Field("MGNT:L0B:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLYCORSGO.DOL1")
#! Field("MGNT:L0B:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLYCORSGO.LNK1")
#! Link("MGNT:L0B:1:ALLYCORSGO.LNK1","MGNT:L0B:1:ALLYCORS.VAL")
#! Record("MGNT:L0B:1:ALLYCORS",540,102,0,0,"MGNT:L0B:1:ALLYCORS")
#! Field("MGNT:L0B:1:ALLYCORS.VAL",16777215,0,"MGNT:L0B:1:ALLYCORS.VAL")
#! Field("MGNT:L0B:1:ALLYCORS.FLNK",16777215,1,"MGNT:L0B:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:L0B:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:L0B:1:SOLNSWITCH")
}

record(seq, "MGNT:L0B:1:SOLNSWITCH") {
  field(DOL1, "MGNT:L0B:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:SOLNCTRL")
}

record(seq, "MGNT:L0B:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:SOLNCTRL",20,10,0,0,"MGNT:L0B:1:SOLNCTRL")
#! Field("MGNT:L0B:1:SOLNCTRL.FLNK",16777215,1,"MGNT:L0B:1:SOLNCTRL.FLNK")
#! Link("MGNT:L0B:1:SOLNCTRL.FLNK","MGNT:L0B:1:SOLNSWITCH")
#! Field("MGNT:L0B:1:SOLNCTRL.FFVL",16777215,1,"MGNT:L0B:1:SOLNCTRL.FFVL")
#! Record("MGNT:L0B:1:SOLNSWITCH",460,322,0,0,"MGNT:L0B:1:SOLNSWITCH")
#! Field("MGNT:L0B:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:L0B:1:SOLNSWITCH.DOL1")
#! Link("MGNT:L0B:1:SOLNSWITCH.DOL1","MGNT:L0B:1:SOLNCTRL.FFVL")
#! Field("MGNT:L0B:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:L0B:1:SOLNSWITCH.LNK1")
#! Field("MGNT:L0B:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:L0B:1:SOLNSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLSOLNSGO",240,96,0,0,"MGNT:L0B:1:ALLSOLNSGO")
#! Field("MGNT:L0B:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:L0B:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:L0B:1:ALLSOLNSGO.LNK1","MGNT:L0B:1:ALLSOLNS.VAL")
#! Record("MGNT:L0B:1:ALLSOLNS",540,102,0,0,"MGNT:L0B:1:ALLSOLNS")
#! Field("MGNT:L0B:1:ALLSOLNS.VAL",16777215,0,"MGNT:L0B:1:ALLSOLNS.VAL")
#! Field("MGNT:L0B:1:ALLSOLNS.FLNK",16777215,1,"MGNT:L0B:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:L0B:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:L0B:1:KICKSWITCH")
}

record(seq, "MGNT:L0B:1:KICKSWITCH") {
  field(DOL1, "MGNT:L0B:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:KICKCTRL")
}

record(seq, "MGNT:L0B:1:ALLKICKSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:KICKCTRL",20,10,0,0,"MGNT:L0B:1:KICKCTRL")
#! Field("MGNT:L0B:1:KICKCTRL.FLNK",16777215,1,"MGNT:L0B:1:KICKCTRL.FLNK")
#! Link("MGNT:L0B:1:KICKCTRL.FLNK","MGNT:L0B:1:KICKSWITCH")
#! Field("MGNT:L0B:1:KICKCTRL.FFVL",16777215,1,"MGNT:L0B:1:KICKCTRL.FFVL")
#! Record("MGNT:L0B:1:KICKSWITCH",460,322,0,0,"MGNT:L0B:1:KICKSWITCH")
#! Field("MGNT:L0B:1:KICKSWITCH.DOL1",16777215,0,"MGNT:L0B:1:KICKSWITCH.DOL1")
#! Link("MGNT:L0B:1:KICKSWITCH.DOL1","MGNT:L0B:1:KICKCTRL.FFVL")
#! Field("MGNT:L0B:1:KICKSWITCH.LNK1",16777215,1,"MGNT:L0B:1:KICKSWITCH.LNK1")
#! Field("MGNT:L0B:1:KICKSWITCH.FLNK",16777215,1,"MGNT:L0B:1:KICKSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLKICKSGO",240,96,0,0,"MGNT:L0B:1:ALLKICKSGO")
#! Field("MGNT:L0B:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLKICKSGO.DOL1")
#! Field("MGNT:L0B:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLKICKSGO.LNK1")
#! Link("MGNT:L0B:1:ALLKICKSGO.LNK1","MGNT:L0B:1:ALLKICKS.VAL")
#! Record("MGNT:L0B:1:ALLKICKS",540,102,0,0,"MGNT:L0B:1:ALLKICKS")
#! Field("MGNT:L0B:1:ALLKICKS.VAL",16777215,0,"MGNT:L0B:1:ALLKICKS.VAL")
#! Field("MGNT:L0B:1:ALLKICKS.FLNK",16777215,1,"MGNT:L0B:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:L0B:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:L0B:1:SEXTSWITCH")
}

record(seq, "MGNT:L0B:1:SEXTSWITCH") {
  field(DOL1, "MGNT:L0B:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:L0B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L0B:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L0B:1:SEXTCTRL")
}

record(seq, "MGNT:L0B:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:L0B:1:ALLSTAR")
  field(LNK1, "MGNT:L0B:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:L0B:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L0B:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L0B:1:SEXTCTRL",20,10,0,0,"MGNT:L0B:1:SEXTCTRL")
#! Field("MGNT:L0B:1:SEXTCTRL.FLNK",16777215,1,"MGNT:L0B:1:SEXTCTRL.FLNK")
#! Link("MGNT:L0B:1:SEXTCTRL.FLNK","MGNT:L0B:1:SEXTSWITCH")
#! Field("MGNT:L0B:1:SEXTCTRL.FFVL",16777215,1,"MGNT:L0B:1:SEXTCTRL.FFVL")
#! Record("MGNT:L0B:1:SEXTSWITCH",460,322,0,0,"MGNT:L0B:1:SEXTSWITCH")
#! Field("MGNT:L0B:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:L0B:1:SEXTSWITCH.DOL1")
#! Link("MGNT:L0B:1:SEXTSWITCH.DOL1","MGNT:L0B:1:SEXTCTRL.FFVL")
#! Field("MGNT:L0B:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:L0B:1:SEXTSWITCH.LNK1")
#! Field("MGNT:L0B:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:L0B:1:SEXTSWITCH.FLNK")
#! Record("MGNT:L0B:1:ALLSEXTSGO",240,96,0,0,"MGNT:L0B:1:ALLSEXTSGO")
#! Field("MGNT:L0B:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:L0B:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:L0B:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:L0B:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:L0B:1:ALLSEXTSGO.LNK1","MGNT:L0B:1:ALLSEXTS.VAL")
#! Record("MGNT:L0B:1:ALLSEXTS",540,102,0,0,"MGNT:L0B:1:ALLSEXTS")
#! Field("MGNT:L0B:1:ALLSEXTS.VAL",16777215,0,"MGNT:L0B:1:ALLSEXTS.VAL")
#! Field("MGNT:L0B:1:ALLSEXTS.FLNK",16777215,1,"MGNT:L0B:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:DIAG0:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:DIAG0:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:DIAG0:1:CTRL CA PP")
  field(LNK2, "MGNT:DIAG0:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:DIAG0:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:DIAG0:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:DIAG0:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:DIAG0:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:DIAG0:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:DIAG0:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:DIAG0:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:DIAG0:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:DIAG0:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:DIAG0:1:ALLSWITCH")
}

record(seq, "MGNT:DIAG0:1:ALLSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:CTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:CTRL")
}

record(bo, "MGNT:DIAG0:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLSTARGO")
}

record(fanout, "MGNT:DIAG0:1:ALLSTARGO") {
  field(LNK1, "MGNT:DIAG0:1:ALLBENDSGO")
  field(LNK2, "MGNT:DIAG0:1:ALLBTRMSGO")
  field(LNK3, "MGNT:DIAG0:1:ALLLGPSSGO")
  field(LNK4, "MGNT:DIAG0:1:ALLQUADSGO")
  field(LNK5, "MGNT:DIAG0:1:ALLXCORSGO")
  field(LNK6, "MGNT:DIAG0:1:ALLYCORSGO")
  field(FLNK, "MGNT:DIAG0:1:ALLSTARGO_2")
}
record(fanout, "MGNT:DIAG0:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:DIAG0:1:ALLSOLNSGO")
  field(LNK2, "MGNT:DIAG0:1:ALLKICKSGO")
  field(LNK3, "MGNT:DIAG0:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:DIAG0:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:DIAG0:1:BENDSWITCH")
}

record(seq, "MGNT:DIAG0:1:BENDSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:BENDCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLBENDSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:BENDCTRL",20,10,0,0,"MGNT:DIAG0:1:BENDCTRL")
#! Field("MGNT:DIAG0:1:BENDCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:BENDCTRL.FLNK")
#! Link("MGNT:DIAG0:1:BENDCTRL.FLNK","MGNT:DIAG0:1:BENDSWITCH")
#! Field("MGNT:DIAG0:1:BENDCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:BENDCTRL.FFVL")
#! Record("MGNT:DIAG0:1:BENDSWITCH",460,322,0,0,"MGNT:DIAG0:1:BENDSWITCH")
#! Field("MGNT:DIAG0:1:BENDSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:BENDSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:BENDSWITCH.DOL1","MGNT:DIAG0:1:BENDCTRL.FFVL")
#! Field("MGNT:DIAG0:1:BENDSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:BENDSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:BENDSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:BENDSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLBENDSGO",240,96,0,0,"MGNT:DIAG0:1:ALLBENDSGO")
#! Field("MGNT:DIAG0:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLBENDSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLBENDSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLBENDSGO.LNK1","MGNT:DIAG0:1:ALLBENDS.VAL")
#! Record("MGNT:DIAG0:1:ALLBENDS",540,102,0,0,"MGNT:DIAG0:1:ALLBENDS")
#! Field("MGNT:DIAG0:1:ALLBENDS.VAL",16777215,0,"MGNT:DIAG0:1:ALLBENDS.VAL")
#! Field("MGNT:DIAG0:1:ALLBENDS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:DIAG0:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DIAG0:1:BTRMSWITCH")
}

record(seq, "MGNT:DIAG0:1:BTRMSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:BTRMCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:BTRMCTRL",20,10,0,0,"MGNT:DIAG0:1:BTRMCTRL")
#! Field("MGNT:DIAG0:1:BTRMCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:BTRMCTRL.FLNK")
#! Link("MGNT:DIAG0:1:BTRMCTRL.FLNK","MGNT:DIAG0:1:BTRMSWITCH")
#! Field("MGNT:DIAG0:1:BTRMCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:BTRMCTRL.FFVL")
#! Record("MGNT:DIAG0:1:BTRMSWITCH",460,322,0,0,"MGNT:DIAG0:1:BTRMSWITCH")
#! Field("MGNT:DIAG0:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:BTRMSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:BTRMSWITCH.DOL1","MGNT:DIAG0:1:BTRMCTRL.FFVL")
#! Field("MGNT:DIAG0:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:BTRMSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:BTRMSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLBTRMSGO",240,96,0,0,"MGNT:DIAG0:1:ALLBTRMSGO")
#! Field("MGNT:DIAG0:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLBTRMSGO.LNK1","MGNT:DIAG0:1:ALLBTRMS.VAL")
#! Record("MGNT:DIAG0:1:ALLBTRMS",540,102,0,0,"MGNT:DIAG0:1:ALLBTRMS")
#! Field("MGNT:DIAG0:1:ALLBTRMS.VAL",16777215,0,"MGNT:DIAG0:1:ALLBTRMS.VAL")
#! Field("MGNT:DIAG0:1:ALLBTRMS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:DIAG0:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DIAG0:1:LGPSSWITCH")
}

record(seq, "MGNT:DIAG0:1:LGPSSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:LGPSCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:LGPSCTRL",20,10,0,0,"MGNT:DIAG0:1:LGPSCTRL")
#! Field("MGNT:DIAG0:1:LGPSCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:LGPSCTRL.FLNK")
#! Link("MGNT:DIAG0:1:LGPSCTRL.FLNK","MGNT:DIAG0:1:LGPSSWITCH")
#! Field("MGNT:DIAG0:1:LGPSCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:LGPSCTRL.FFVL")
#! Record("MGNT:DIAG0:1:LGPSSWITCH",460,322,0,0,"MGNT:DIAG0:1:LGPSSWITCH")
#! Field("MGNT:DIAG0:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:LGPSSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:LGPSSWITCH.DOL1","MGNT:DIAG0:1:LGPSCTRL.FFVL")
#! Field("MGNT:DIAG0:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:LGPSSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:LGPSSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLLGPSSGO",240,96,0,0,"MGNT:DIAG0:1:ALLLGPSSGO")
#! Field("MGNT:DIAG0:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLLGPSSGO.LNK1","MGNT:DIAG0:1:ALLLGPSS.VAL")
#! Record("MGNT:DIAG0:1:ALLLGPSS",540,102,0,0,"MGNT:DIAG0:1:ALLLGPSS")
#! Field("MGNT:DIAG0:1:ALLLGPSS.VAL",16777215,0,"MGNT:DIAG0:1:ALLLGPSS.VAL")
#! Field("MGNT:DIAG0:1:ALLLGPSS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:DIAG0:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:DIAG0:1:QUADSWITCH")
}

record(seq, "MGNT:DIAG0:1:QUADSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:QUADCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLQUADSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:QUADCTRL",20,10,0,0,"MGNT:DIAG0:1:QUADCTRL")
#! Field("MGNT:DIAG0:1:QUADCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:QUADCTRL.FLNK")
#! Link("MGNT:DIAG0:1:QUADCTRL.FLNK","MGNT:DIAG0:1:QUADSWITCH")
#! Field("MGNT:DIAG0:1:QUADCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:QUADCTRL.FFVL")
#! Record("MGNT:DIAG0:1:QUADSWITCH",460,322,0,0,"MGNT:DIAG0:1:QUADSWITCH")
#! Field("MGNT:DIAG0:1:QUADSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:QUADSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:QUADSWITCH.DOL1","MGNT:DIAG0:1:QUADCTRL.FFVL")
#! Field("MGNT:DIAG0:1:QUADSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:QUADSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:QUADSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:QUADSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLQUADSGO",240,96,0,0,"MGNT:DIAG0:1:ALLQUADSGO")
#! Field("MGNT:DIAG0:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLQUADSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLQUADSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLQUADSGO.LNK1","MGNT:DIAG0:1:ALLQUADS.VAL")
#! Record("MGNT:DIAG0:1:ALLQUADS",540,102,0,0,"MGNT:DIAG0:1:ALLQUADS")
#! Field("MGNT:DIAG0:1:ALLQUADS.VAL",16777215,0,"MGNT:DIAG0:1:ALLQUADS.VAL")
#! Field("MGNT:DIAG0:1:ALLQUADS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:DIAG0:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:DIAG0:1:XCORSWITCH")
}

record(seq, "MGNT:DIAG0:1:XCORSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:XCORCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLXCORSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:XCORCTRL",20,10,0,0,"MGNT:DIAG0:1:XCORCTRL")
#! Field("MGNT:DIAG0:1:XCORCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:XCORCTRL.FLNK")
#! Link("MGNT:DIAG0:1:XCORCTRL.FLNK","MGNT:DIAG0:1:XCORSWITCH")
#! Field("MGNT:DIAG0:1:XCORCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:XCORCTRL.FFVL")
#! Record("MGNT:DIAG0:1:XCORSWITCH",460,322,0,0,"MGNT:DIAG0:1:XCORSWITCH")
#! Field("MGNT:DIAG0:1:XCORSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:XCORSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:XCORSWITCH.DOL1","MGNT:DIAG0:1:XCORCTRL.FFVL")
#! Field("MGNT:DIAG0:1:XCORSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:XCORSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:XCORSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:XCORSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLXCORSGO",240,96,0,0,"MGNT:DIAG0:1:ALLXCORSGO")
#! Field("MGNT:DIAG0:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLXCORSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLXCORSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLXCORSGO.LNK1","MGNT:DIAG0:1:ALLXCORS.VAL")
#! Record("MGNT:DIAG0:1:ALLXCORS",540,102,0,0,"MGNT:DIAG0:1:ALLXCORS")
#! Field("MGNT:DIAG0:1:ALLXCORS.VAL",16777215,0,"MGNT:DIAG0:1:ALLXCORS.VAL")
#! Field("MGNT:DIAG0:1:ALLXCORS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:DIAG0:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:DIAG0:1:YCORSWITCH")
}

record(seq, "MGNT:DIAG0:1:YCORSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:YCORCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLYCORSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:YCORCTRL",20,10,0,0,"MGNT:DIAG0:1:YCORCTRL")
#! Field("MGNT:DIAG0:1:YCORCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:YCORCTRL.FLNK")
#! Link("MGNT:DIAG0:1:YCORCTRL.FLNK","MGNT:DIAG0:1:YCORSWITCH")
#! Field("MGNT:DIAG0:1:YCORCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:YCORCTRL.FFVL")
#! Record("MGNT:DIAG0:1:YCORSWITCH",460,322,0,0,"MGNT:DIAG0:1:YCORSWITCH")
#! Field("MGNT:DIAG0:1:YCORSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:YCORSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:YCORSWITCH.DOL1","MGNT:DIAG0:1:YCORCTRL.FFVL")
#! Field("MGNT:DIAG0:1:YCORSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:YCORSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:YCORSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:YCORSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLYCORSGO",240,96,0,0,"MGNT:DIAG0:1:ALLYCORSGO")
#! Field("MGNT:DIAG0:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLYCORSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLYCORSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLYCORSGO.LNK1","MGNT:DIAG0:1:ALLYCORS.VAL")
#! Record("MGNT:DIAG0:1:ALLYCORS",540,102,0,0,"MGNT:DIAG0:1:ALLYCORS")
#! Field("MGNT:DIAG0:1:ALLYCORS.VAL",16777215,0,"MGNT:DIAG0:1:ALLYCORS.VAL")
#! Field("MGNT:DIAG0:1:ALLYCORS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:DIAG0:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:DIAG0:1:SOLNSWITCH")
}

record(seq, "MGNT:DIAG0:1:SOLNSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:SOLNCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:SOLNCTRL",20,10,0,0,"MGNT:DIAG0:1:SOLNCTRL")
#! Field("MGNT:DIAG0:1:SOLNCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:SOLNCTRL.FLNK")
#! Link("MGNT:DIAG0:1:SOLNCTRL.FLNK","MGNT:DIAG0:1:SOLNSWITCH")
#! Field("MGNT:DIAG0:1:SOLNCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:SOLNCTRL.FFVL")
#! Record("MGNT:DIAG0:1:SOLNSWITCH",460,322,0,0,"MGNT:DIAG0:1:SOLNSWITCH")
#! Field("MGNT:DIAG0:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:SOLNSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:SOLNSWITCH.DOL1","MGNT:DIAG0:1:SOLNCTRL.FFVL")
#! Field("MGNT:DIAG0:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:SOLNSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:SOLNSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLSOLNSGO",240,96,0,0,"MGNT:DIAG0:1:ALLSOLNSGO")
#! Field("MGNT:DIAG0:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLSOLNSGO.LNK1","MGNT:DIAG0:1:ALLSOLNS.VAL")
#! Record("MGNT:DIAG0:1:ALLSOLNS",540,102,0,0,"MGNT:DIAG0:1:ALLSOLNS")
#! Field("MGNT:DIAG0:1:ALLSOLNS.VAL",16777215,0,"MGNT:DIAG0:1:ALLSOLNS.VAL")
#! Field("MGNT:DIAG0:1:ALLSOLNS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:DIAG0:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:DIAG0:1:KICKSWITCH")
}

record(seq, "MGNT:DIAG0:1:KICKSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:KICKCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLKICKSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:KICKCTRL",20,10,0,0,"MGNT:DIAG0:1:KICKCTRL")
#! Field("MGNT:DIAG0:1:KICKCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:KICKCTRL.FLNK")
#! Link("MGNT:DIAG0:1:KICKCTRL.FLNK","MGNT:DIAG0:1:KICKSWITCH")
#! Field("MGNT:DIAG0:1:KICKCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:KICKCTRL.FFVL")
#! Record("MGNT:DIAG0:1:KICKSWITCH",460,322,0,0,"MGNT:DIAG0:1:KICKSWITCH")
#! Field("MGNT:DIAG0:1:KICKSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:KICKSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:KICKSWITCH.DOL1","MGNT:DIAG0:1:KICKCTRL.FFVL")
#! Field("MGNT:DIAG0:1:KICKSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:KICKSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:KICKSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:KICKSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLKICKSGO",240,96,0,0,"MGNT:DIAG0:1:ALLKICKSGO")
#! Field("MGNT:DIAG0:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLKICKSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLKICKSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLKICKSGO.LNK1","MGNT:DIAG0:1:ALLKICKS.VAL")
#! Record("MGNT:DIAG0:1:ALLKICKS",540,102,0,0,"MGNT:DIAG0:1:ALLKICKS")
#! Field("MGNT:DIAG0:1:ALLKICKS.VAL",16777215,0,"MGNT:DIAG0:1:ALLKICKS.VAL")
#! Field("MGNT:DIAG0:1:ALLKICKS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:DIAG0:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:DIAG0:1:SEXTSWITCH")
}

record(seq, "MGNT:DIAG0:1:SEXTSWITCH") {
  field(DOL1, "MGNT:DIAG0:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:DIAG0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DIAG0:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DIAG0:1:SEXTCTRL")
}

record(seq, "MGNT:DIAG0:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:DIAG0:1:ALLSTAR")
  field(LNK1, "MGNT:DIAG0:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:DIAG0:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DIAG0:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DIAG0:1:SEXTCTRL",20,10,0,0,"MGNT:DIAG0:1:SEXTCTRL")
#! Field("MGNT:DIAG0:1:SEXTCTRL.FLNK",16777215,1,"MGNT:DIAG0:1:SEXTCTRL.FLNK")
#! Link("MGNT:DIAG0:1:SEXTCTRL.FLNK","MGNT:DIAG0:1:SEXTSWITCH")
#! Field("MGNT:DIAG0:1:SEXTCTRL.FFVL",16777215,1,"MGNT:DIAG0:1:SEXTCTRL.FFVL")
#! Record("MGNT:DIAG0:1:SEXTSWITCH",460,322,0,0,"MGNT:DIAG0:1:SEXTSWITCH")
#! Field("MGNT:DIAG0:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:DIAG0:1:SEXTSWITCH.DOL1")
#! Link("MGNT:DIAG0:1:SEXTSWITCH.DOL1","MGNT:DIAG0:1:SEXTCTRL.FFVL")
#! Field("MGNT:DIAG0:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:DIAG0:1:SEXTSWITCH.LNK1")
#! Field("MGNT:DIAG0:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:DIAG0:1:SEXTSWITCH.FLNK")
#! Record("MGNT:DIAG0:1:ALLSEXTSGO",240,96,0,0,"MGNT:DIAG0:1:ALLSEXTSGO")
#! Field("MGNT:DIAG0:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:DIAG0:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:DIAG0:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:DIAG0:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:DIAG0:1:ALLSEXTSGO.LNK1","MGNT:DIAG0:1:ALLSEXTS.VAL")
#! Record("MGNT:DIAG0:1:ALLSEXTS",540,102,0,0,"MGNT:DIAG0:1:ALLSEXTS")
#! Field("MGNT:DIAG0:1:ALLSEXTS.VAL",16777215,0,"MGNT:DIAG0:1:ALLSEXTS.VAL")
#! Field("MGNT:DIAG0:1:ALLSEXTS.FLNK",16777215,1,"MGNT:DIAG0:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:HTR:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:HTR:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:HTR:1:CTRL CA PP")
  field(LNK2, "MGNT:HTR:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:HTR:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:HTR:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:HTR:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:HTR:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:HTR:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:HTR:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:HTR:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:HTR:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:HTR:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:HTR:1:ALLSWITCH")
}

record(seq, "MGNT:HTR:1:ALLSWITCH") {
  field(DOL1, "MGNT:HTR:1:CTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:CTRL")
}

record(bo, "MGNT:HTR:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:HTR:1:ALLSTARGO")
}

record(fanout, "MGNT:HTR:1:ALLSTARGO") {
  field(LNK1, "MGNT:HTR:1:ALLBENDSGO")
  field(LNK2, "MGNT:HTR:1:ALLBTRMSGO")
  field(LNK3, "MGNT:HTR:1:ALLLGPSSGO")
  field(LNK4, "MGNT:HTR:1:ALLQUADSGO")
  field(LNK5, "MGNT:HTR:1:ALLXCORSGO")
  field(LNK6, "MGNT:HTR:1:ALLYCORSGO")
  field(FLNK, "MGNT:HTR:1:ALLSTARGO_2")
}
record(fanout, "MGNT:HTR:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:HTR:1:ALLSOLNSGO")
  field(LNK2, "MGNT:HTR:1:ALLKICKSGO")
  field(LNK3, "MGNT:HTR:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:HTR:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:HTR:1:BENDSWITCH")
}

record(seq, "MGNT:HTR:1:BENDSWITCH") {
  field(DOL1, "MGNT:HTR:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:BENDCTRL")
}

record(seq, "MGNT:HTR:1:ALLBENDSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:BENDCTRL",20,10,0,0,"MGNT:HTR:1:BENDCTRL")
#! Field("MGNT:HTR:1:BENDCTRL.FLNK",16777215,1,"MGNT:HTR:1:BENDCTRL.FLNK")
#! Link("MGNT:HTR:1:BENDCTRL.FLNK","MGNT:HTR:1:BENDSWITCH")
#! Field("MGNT:HTR:1:BENDCTRL.FFVL",16777215,1,"MGNT:HTR:1:BENDCTRL.FFVL")
#! Record("MGNT:HTR:1:BENDSWITCH",460,322,0,0,"MGNT:HTR:1:BENDSWITCH")
#! Field("MGNT:HTR:1:BENDSWITCH.DOL1",16777215,0,"MGNT:HTR:1:BENDSWITCH.DOL1")
#! Link("MGNT:HTR:1:BENDSWITCH.DOL1","MGNT:HTR:1:BENDCTRL.FFVL")
#! Field("MGNT:HTR:1:BENDSWITCH.LNK1",16777215,1,"MGNT:HTR:1:BENDSWITCH.LNK1")
#! Field("MGNT:HTR:1:BENDSWITCH.FLNK",16777215,1,"MGNT:HTR:1:BENDSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLBENDSGO",240,96,0,0,"MGNT:HTR:1:ALLBENDSGO")
#! Field("MGNT:HTR:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLBENDSGO.DOL1")
#! Field("MGNT:HTR:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLBENDSGO.LNK1")
#! Link("MGNT:HTR:1:ALLBENDSGO.LNK1","MGNT:HTR:1:ALLBENDS.VAL")
#! Record("MGNT:HTR:1:ALLBENDS",540,102,0,0,"MGNT:HTR:1:ALLBENDS")
#! Field("MGNT:HTR:1:ALLBENDS.VAL",16777215,0,"MGNT:HTR:1:ALLBENDS.VAL")
#! Field("MGNT:HTR:1:ALLBENDS.FLNK",16777215,1,"MGNT:HTR:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:HTR:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:HTR:1:BTRMSWITCH")
}

record(seq, "MGNT:HTR:1:BTRMSWITCH") {
  field(DOL1, "MGNT:HTR:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:BTRMCTRL")
}

record(seq, "MGNT:HTR:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:BTRMCTRL",20,10,0,0,"MGNT:HTR:1:BTRMCTRL")
#! Field("MGNT:HTR:1:BTRMCTRL.FLNK",16777215,1,"MGNT:HTR:1:BTRMCTRL.FLNK")
#! Link("MGNT:HTR:1:BTRMCTRL.FLNK","MGNT:HTR:1:BTRMSWITCH")
#! Field("MGNT:HTR:1:BTRMCTRL.FFVL",16777215,1,"MGNT:HTR:1:BTRMCTRL.FFVL")
#! Record("MGNT:HTR:1:BTRMSWITCH",460,322,0,0,"MGNT:HTR:1:BTRMSWITCH")
#! Field("MGNT:HTR:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:HTR:1:BTRMSWITCH.DOL1")
#! Link("MGNT:HTR:1:BTRMSWITCH.DOL1","MGNT:HTR:1:BTRMCTRL.FFVL")
#! Field("MGNT:HTR:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:HTR:1:BTRMSWITCH.LNK1")
#! Field("MGNT:HTR:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:HTR:1:BTRMSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLBTRMSGO",240,96,0,0,"MGNT:HTR:1:ALLBTRMSGO")
#! Field("MGNT:HTR:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:HTR:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:HTR:1:ALLBTRMSGO.LNK1","MGNT:HTR:1:ALLBTRMS.VAL")
#! Record("MGNT:HTR:1:ALLBTRMS",540,102,0,0,"MGNT:HTR:1:ALLBTRMS")
#! Field("MGNT:HTR:1:ALLBTRMS.VAL",16777215,0,"MGNT:HTR:1:ALLBTRMS.VAL")
#! Field("MGNT:HTR:1:ALLBTRMS.FLNK",16777215,1,"MGNT:HTR:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:HTR:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:HTR:1:LGPSSWITCH")
}

record(seq, "MGNT:HTR:1:LGPSSWITCH") {
  field(DOL1, "MGNT:HTR:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:LGPSCTRL")
}

record(seq, "MGNT:HTR:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:LGPSCTRL",20,10,0,0,"MGNT:HTR:1:LGPSCTRL")
#! Field("MGNT:HTR:1:LGPSCTRL.FLNK",16777215,1,"MGNT:HTR:1:LGPSCTRL.FLNK")
#! Link("MGNT:HTR:1:LGPSCTRL.FLNK","MGNT:HTR:1:LGPSSWITCH")
#! Field("MGNT:HTR:1:LGPSCTRL.FFVL",16777215,1,"MGNT:HTR:1:LGPSCTRL.FFVL")
#! Record("MGNT:HTR:1:LGPSSWITCH",460,322,0,0,"MGNT:HTR:1:LGPSSWITCH")
#! Field("MGNT:HTR:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:HTR:1:LGPSSWITCH.DOL1")
#! Link("MGNT:HTR:1:LGPSSWITCH.DOL1","MGNT:HTR:1:LGPSCTRL.FFVL")
#! Field("MGNT:HTR:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:HTR:1:LGPSSWITCH.LNK1")
#! Field("MGNT:HTR:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:HTR:1:LGPSSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLLGPSSGO",240,96,0,0,"MGNT:HTR:1:ALLLGPSSGO")
#! Field("MGNT:HTR:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:HTR:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:HTR:1:ALLLGPSSGO.LNK1","MGNT:HTR:1:ALLLGPSS.VAL")
#! Record("MGNT:HTR:1:ALLLGPSS",540,102,0,0,"MGNT:HTR:1:ALLLGPSS")
#! Field("MGNT:HTR:1:ALLLGPSS.VAL",16777215,0,"MGNT:HTR:1:ALLLGPSS.VAL")
#! Field("MGNT:HTR:1:ALLLGPSS.FLNK",16777215,1,"MGNT:HTR:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:HTR:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:HTR:1:QUADSWITCH")
}

record(seq, "MGNT:HTR:1:QUADSWITCH") {
  field(DOL1, "MGNT:HTR:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:QUADCTRL")
}

record(seq, "MGNT:HTR:1:ALLQUADSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:QUADCTRL",20,10,0,0,"MGNT:HTR:1:QUADCTRL")
#! Field("MGNT:HTR:1:QUADCTRL.FLNK",16777215,1,"MGNT:HTR:1:QUADCTRL.FLNK")
#! Link("MGNT:HTR:1:QUADCTRL.FLNK","MGNT:HTR:1:QUADSWITCH")
#! Field("MGNT:HTR:1:QUADCTRL.FFVL",16777215,1,"MGNT:HTR:1:QUADCTRL.FFVL")
#! Record("MGNT:HTR:1:QUADSWITCH",460,322,0,0,"MGNT:HTR:1:QUADSWITCH")
#! Field("MGNT:HTR:1:QUADSWITCH.DOL1",16777215,0,"MGNT:HTR:1:QUADSWITCH.DOL1")
#! Link("MGNT:HTR:1:QUADSWITCH.DOL1","MGNT:HTR:1:QUADCTRL.FFVL")
#! Field("MGNT:HTR:1:QUADSWITCH.LNK1",16777215,1,"MGNT:HTR:1:QUADSWITCH.LNK1")
#! Field("MGNT:HTR:1:QUADSWITCH.FLNK",16777215,1,"MGNT:HTR:1:QUADSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLQUADSGO",240,96,0,0,"MGNT:HTR:1:ALLQUADSGO")
#! Field("MGNT:HTR:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLQUADSGO.DOL1")
#! Field("MGNT:HTR:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLQUADSGO.LNK1")
#! Link("MGNT:HTR:1:ALLQUADSGO.LNK1","MGNT:HTR:1:ALLQUADS.VAL")
#! Record("MGNT:HTR:1:ALLQUADS",540,102,0,0,"MGNT:HTR:1:ALLQUADS")
#! Field("MGNT:HTR:1:ALLQUADS.VAL",16777215,0,"MGNT:HTR:1:ALLQUADS.VAL")
#! Field("MGNT:HTR:1:ALLQUADS.FLNK",16777215,1,"MGNT:HTR:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:HTR:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:HTR:1:XCORSWITCH")
}

record(seq, "MGNT:HTR:1:XCORSWITCH") {
  field(DOL1, "MGNT:HTR:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:XCORCTRL")
}

record(seq, "MGNT:HTR:1:ALLXCORSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:XCORCTRL",20,10,0,0,"MGNT:HTR:1:XCORCTRL")
#! Field("MGNT:HTR:1:XCORCTRL.FLNK",16777215,1,"MGNT:HTR:1:XCORCTRL.FLNK")
#! Link("MGNT:HTR:1:XCORCTRL.FLNK","MGNT:HTR:1:XCORSWITCH")
#! Field("MGNT:HTR:1:XCORCTRL.FFVL",16777215,1,"MGNT:HTR:1:XCORCTRL.FFVL")
#! Record("MGNT:HTR:1:XCORSWITCH",460,322,0,0,"MGNT:HTR:1:XCORSWITCH")
#! Field("MGNT:HTR:1:XCORSWITCH.DOL1",16777215,0,"MGNT:HTR:1:XCORSWITCH.DOL1")
#! Link("MGNT:HTR:1:XCORSWITCH.DOL1","MGNT:HTR:1:XCORCTRL.FFVL")
#! Field("MGNT:HTR:1:XCORSWITCH.LNK1",16777215,1,"MGNT:HTR:1:XCORSWITCH.LNK1")
#! Field("MGNT:HTR:1:XCORSWITCH.FLNK",16777215,1,"MGNT:HTR:1:XCORSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLXCORSGO",240,96,0,0,"MGNT:HTR:1:ALLXCORSGO")
#! Field("MGNT:HTR:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLXCORSGO.DOL1")
#! Field("MGNT:HTR:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLXCORSGO.LNK1")
#! Link("MGNT:HTR:1:ALLXCORSGO.LNK1","MGNT:HTR:1:ALLXCORS.VAL")
#! Record("MGNT:HTR:1:ALLXCORS",540,102,0,0,"MGNT:HTR:1:ALLXCORS")
#! Field("MGNT:HTR:1:ALLXCORS.VAL",16777215,0,"MGNT:HTR:1:ALLXCORS.VAL")
#! Field("MGNT:HTR:1:ALLXCORS.FLNK",16777215,1,"MGNT:HTR:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:HTR:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:HTR:1:YCORSWITCH")
}

record(seq, "MGNT:HTR:1:YCORSWITCH") {
  field(DOL1, "MGNT:HTR:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:YCORCTRL")
}

record(seq, "MGNT:HTR:1:ALLYCORSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:YCORCTRL",20,10,0,0,"MGNT:HTR:1:YCORCTRL")
#! Field("MGNT:HTR:1:YCORCTRL.FLNK",16777215,1,"MGNT:HTR:1:YCORCTRL.FLNK")
#! Link("MGNT:HTR:1:YCORCTRL.FLNK","MGNT:HTR:1:YCORSWITCH")
#! Field("MGNT:HTR:1:YCORCTRL.FFVL",16777215,1,"MGNT:HTR:1:YCORCTRL.FFVL")
#! Record("MGNT:HTR:1:YCORSWITCH",460,322,0,0,"MGNT:HTR:1:YCORSWITCH")
#! Field("MGNT:HTR:1:YCORSWITCH.DOL1",16777215,0,"MGNT:HTR:1:YCORSWITCH.DOL1")
#! Link("MGNT:HTR:1:YCORSWITCH.DOL1","MGNT:HTR:1:YCORCTRL.FFVL")
#! Field("MGNT:HTR:1:YCORSWITCH.LNK1",16777215,1,"MGNT:HTR:1:YCORSWITCH.LNK1")
#! Field("MGNT:HTR:1:YCORSWITCH.FLNK",16777215,1,"MGNT:HTR:1:YCORSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLYCORSGO",240,96,0,0,"MGNT:HTR:1:ALLYCORSGO")
#! Field("MGNT:HTR:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLYCORSGO.DOL1")
#! Field("MGNT:HTR:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLYCORSGO.LNK1")
#! Link("MGNT:HTR:1:ALLYCORSGO.LNK1","MGNT:HTR:1:ALLYCORS.VAL")
#! Record("MGNT:HTR:1:ALLYCORS",540,102,0,0,"MGNT:HTR:1:ALLYCORS")
#! Field("MGNT:HTR:1:ALLYCORS.VAL",16777215,0,"MGNT:HTR:1:ALLYCORS.VAL")
#! Field("MGNT:HTR:1:ALLYCORS.FLNK",16777215,1,"MGNT:HTR:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:HTR:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:HTR:1:SOLNSWITCH")
}

record(seq, "MGNT:HTR:1:SOLNSWITCH") {
  field(DOL1, "MGNT:HTR:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:SOLNCTRL")
}

record(seq, "MGNT:HTR:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:SOLNCTRL",20,10,0,0,"MGNT:HTR:1:SOLNCTRL")
#! Field("MGNT:HTR:1:SOLNCTRL.FLNK",16777215,1,"MGNT:HTR:1:SOLNCTRL.FLNK")
#! Link("MGNT:HTR:1:SOLNCTRL.FLNK","MGNT:HTR:1:SOLNSWITCH")
#! Field("MGNT:HTR:1:SOLNCTRL.FFVL",16777215,1,"MGNT:HTR:1:SOLNCTRL.FFVL")
#! Record("MGNT:HTR:1:SOLNSWITCH",460,322,0,0,"MGNT:HTR:1:SOLNSWITCH")
#! Field("MGNT:HTR:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:HTR:1:SOLNSWITCH.DOL1")
#! Link("MGNT:HTR:1:SOLNSWITCH.DOL1","MGNT:HTR:1:SOLNCTRL.FFVL")
#! Field("MGNT:HTR:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:HTR:1:SOLNSWITCH.LNK1")
#! Field("MGNT:HTR:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:HTR:1:SOLNSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLSOLNSGO",240,96,0,0,"MGNT:HTR:1:ALLSOLNSGO")
#! Field("MGNT:HTR:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:HTR:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:HTR:1:ALLSOLNSGO.LNK1","MGNT:HTR:1:ALLSOLNS.VAL")
#! Record("MGNT:HTR:1:ALLSOLNS",540,102,0,0,"MGNT:HTR:1:ALLSOLNS")
#! Field("MGNT:HTR:1:ALLSOLNS.VAL",16777215,0,"MGNT:HTR:1:ALLSOLNS.VAL")
#! Field("MGNT:HTR:1:ALLSOLNS.FLNK",16777215,1,"MGNT:HTR:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:HTR:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:HTR:1:KICKSWITCH")
}

record(seq, "MGNT:HTR:1:KICKSWITCH") {
  field(DOL1, "MGNT:HTR:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:KICKCTRL")
}

record(seq, "MGNT:HTR:1:ALLKICKSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:KICKCTRL",20,10,0,0,"MGNT:HTR:1:KICKCTRL")
#! Field("MGNT:HTR:1:KICKCTRL.FLNK",16777215,1,"MGNT:HTR:1:KICKCTRL.FLNK")
#! Link("MGNT:HTR:1:KICKCTRL.FLNK","MGNT:HTR:1:KICKSWITCH")
#! Field("MGNT:HTR:1:KICKCTRL.FFVL",16777215,1,"MGNT:HTR:1:KICKCTRL.FFVL")
#! Record("MGNT:HTR:1:KICKSWITCH",460,322,0,0,"MGNT:HTR:1:KICKSWITCH")
#! Field("MGNT:HTR:1:KICKSWITCH.DOL1",16777215,0,"MGNT:HTR:1:KICKSWITCH.DOL1")
#! Link("MGNT:HTR:1:KICKSWITCH.DOL1","MGNT:HTR:1:KICKCTRL.FFVL")
#! Field("MGNT:HTR:1:KICKSWITCH.LNK1",16777215,1,"MGNT:HTR:1:KICKSWITCH.LNK1")
#! Field("MGNT:HTR:1:KICKSWITCH.FLNK",16777215,1,"MGNT:HTR:1:KICKSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLKICKSGO",240,96,0,0,"MGNT:HTR:1:ALLKICKSGO")
#! Field("MGNT:HTR:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLKICKSGO.DOL1")
#! Field("MGNT:HTR:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLKICKSGO.LNK1")
#! Link("MGNT:HTR:1:ALLKICKSGO.LNK1","MGNT:HTR:1:ALLKICKS.VAL")
#! Record("MGNT:HTR:1:ALLKICKS",540,102,0,0,"MGNT:HTR:1:ALLKICKS")
#! Field("MGNT:HTR:1:ALLKICKS.VAL",16777215,0,"MGNT:HTR:1:ALLKICKS.VAL")
#! Field("MGNT:HTR:1:ALLKICKS.FLNK",16777215,1,"MGNT:HTR:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:HTR:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:HTR:1:SEXTSWITCH")
}

record(seq, "MGNT:HTR:1:SEXTSWITCH") {
  field(DOL1, "MGNT:HTR:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:HTR:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:HTR:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:HTR:1:SEXTCTRL")
}

record(seq, "MGNT:HTR:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:HTR:1:ALLSTAR")
  field(LNK1, "MGNT:HTR:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:HTR:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:HTR:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:HTR:1:SEXTCTRL",20,10,0,0,"MGNT:HTR:1:SEXTCTRL")
#! Field("MGNT:HTR:1:SEXTCTRL.FLNK",16777215,1,"MGNT:HTR:1:SEXTCTRL.FLNK")
#! Link("MGNT:HTR:1:SEXTCTRL.FLNK","MGNT:HTR:1:SEXTSWITCH")
#! Field("MGNT:HTR:1:SEXTCTRL.FFVL",16777215,1,"MGNT:HTR:1:SEXTCTRL.FFVL")
#! Record("MGNT:HTR:1:SEXTSWITCH",460,322,0,0,"MGNT:HTR:1:SEXTSWITCH")
#! Field("MGNT:HTR:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:HTR:1:SEXTSWITCH.DOL1")
#! Link("MGNT:HTR:1:SEXTSWITCH.DOL1","MGNT:HTR:1:SEXTCTRL.FFVL")
#! Field("MGNT:HTR:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:HTR:1:SEXTSWITCH.LNK1")
#! Field("MGNT:HTR:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:HTR:1:SEXTSWITCH.FLNK")
#! Record("MGNT:HTR:1:ALLSEXTSGO",240,96,0,0,"MGNT:HTR:1:ALLSEXTSGO")
#! Field("MGNT:HTR:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:HTR:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:HTR:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:HTR:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:HTR:1:ALLSEXTSGO.LNK1","MGNT:HTR:1:ALLSEXTS.VAL")
#! Record("MGNT:HTR:1:ALLSEXTS",540,102,0,0,"MGNT:HTR:1:ALLSEXTS")
#! Field("MGNT:HTR:1:ALLSEXTS.VAL",16777215,0,"MGNT:HTR:1:ALLSEXTS.VAL")
#! Field("MGNT:HTR:1:ALLSEXTS.FLNK",16777215,1,"MGNT:HTR:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:COL0:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:COL0:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:COL0:1:CTRL CA PP")
  field(LNK2, "MGNT:COL0:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:COL0:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:COL0:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:COL0:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:COL0:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:COL0:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:COL0:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:COL0:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:COL0:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:COL0:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:COL0:1:ALLSWITCH")
}

record(seq, "MGNT:COL0:1:ALLSWITCH") {
  field(DOL1, "MGNT:COL0:1:CTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:CTRL")
}

record(bo, "MGNT:COL0:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:COL0:1:ALLSTARGO")
}

record(fanout, "MGNT:COL0:1:ALLSTARGO") {
  field(LNK1, "MGNT:COL0:1:ALLBENDSGO")
  field(LNK2, "MGNT:COL0:1:ALLBTRMSGO")
  field(LNK3, "MGNT:COL0:1:ALLLGPSSGO")
  field(LNK4, "MGNT:COL0:1:ALLQUADSGO")
  field(LNK5, "MGNT:COL0:1:ALLXCORSGO")
  field(LNK6, "MGNT:COL0:1:ALLYCORSGO")
  field(FLNK, "MGNT:COL0:1:ALLSTARGO_2")
}
record(fanout, "MGNT:COL0:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:COL0:1:ALLSOLNSGO")
  field(LNK2, "MGNT:COL0:1:ALLKICKSGO")
  field(LNK3, "MGNT:COL0:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:COL0:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:COL0:1:BENDSWITCH")
}

record(seq, "MGNT:COL0:1:BENDSWITCH") {
  field(DOL1, "MGNT:COL0:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:BENDCTRL")
}

record(seq, "MGNT:COL0:1:ALLBENDSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:BENDCTRL",20,10,0,0,"MGNT:COL0:1:BENDCTRL")
#! Field("MGNT:COL0:1:BENDCTRL.FLNK",16777215,1,"MGNT:COL0:1:BENDCTRL.FLNK")
#! Link("MGNT:COL0:1:BENDCTRL.FLNK","MGNT:COL0:1:BENDSWITCH")
#! Field("MGNT:COL0:1:BENDCTRL.FFVL",16777215,1,"MGNT:COL0:1:BENDCTRL.FFVL")
#! Record("MGNT:COL0:1:BENDSWITCH",460,322,0,0,"MGNT:COL0:1:BENDSWITCH")
#! Field("MGNT:COL0:1:BENDSWITCH.DOL1",16777215,0,"MGNT:COL0:1:BENDSWITCH.DOL1")
#! Link("MGNT:COL0:1:BENDSWITCH.DOL1","MGNT:COL0:1:BENDCTRL.FFVL")
#! Field("MGNT:COL0:1:BENDSWITCH.LNK1",16777215,1,"MGNT:COL0:1:BENDSWITCH.LNK1")
#! Field("MGNT:COL0:1:BENDSWITCH.FLNK",16777215,1,"MGNT:COL0:1:BENDSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLBENDSGO",240,96,0,0,"MGNT:COL0:1:ALLBENDSGO")
#! Field("MGNT:COL0:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLBENDSGO.DOL1")
#! Field("MGNT:COL0:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLBENDSGO.LNK1")
#! Link("MGNT:COL0:1:ALLBENDSGO.LNK1","MGNT:COL0:1:ALLBENDS.VAL")
#! Record("MGNT:COL0:1:ALLBENDS",540,102,0,0,"MGNT:COL0:1:ALLBENDS")
#! Field("MGNT:COL0:1:ALLBENDS.VAL",16777215,0,"MGNT:COL0:1:ALLBENDS.VAL")
#! Field("MGNT:COL0:1:ALLBENDS.FLNK",16777215,1,"MGNT:COL0:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:COL0:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:COL0:1:BTRMSWITCH")
}

record(seq, "MGNT:COL0:1:BTRMSWITCH") {
  field(DOL1, "MGNT:COL0:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:BTRMCTRL")
}

record(seq, "MGNT:COL0:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:BTRMCTRL",20,10,0,0,"MGNT:COL0:1:BTRMCTRL")
#! Field("MGNT:COL0:1:BTRMCTRL.FLNK",16777215,1,"MGNT:COL0:1:BTRMCTRL.FLNK")
#! Link("MGNT:COL0:1:BTRMCTRL.FLNK","MGNT:COL0:1:BTRMSWITCH")
#! Field("MGNT:COL0:1:BTRMCTRL.FFVL",16777215,1,"MGNT:COL0:1:BTRMCTRL.FFVL")
#! Record("MGNT:COL0:1:BTRMSWITCH",460,322,0,0,"MGNT:COL0:1:BTRMSWITCH")
#! Field("MGNT:COL0:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:COL0:1:BTRMSWITCH.DOL1")
#! Link("MGNT:COL0:1:BTRMSWITCH.DOL1","MGNT:COL0:1:BTRMCTRL.FFVL")
#! Field("MGNT:COL0:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:COL0:1:BTRMSWITCH.LNK1")
#! Field("MGNT:COL0:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:COL0:1:BTRMSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLBTRMSGO",240,96,0,0,"MGNT:COL0:1:ALLBTRMSGO")
#! Field("MGNT:COL0:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:COL0:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:COL0:1:ALLBTRMSGO.LNK1","MGNT:COL0:1:ALLBTRMS.VAL")
#! Record("MGNT:COL0:1:ALLBTRMS",540,102,0,0,"MGNT:COL0:1:ALLBTRMS")
#! Field("MGNT:COL0:1:ALLBTRMS.VAL",16777215,0,"MGNT:COL0:1:ALLBTRMS.VAL")
#! Field("MGNT:COL0:1:ALLBTRMS.FLNK",16777215,1,"MGNT:COL0:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:COL0:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:COL0:1:LGPSSWITCH")
}

record(seq, "MGNT:COL0:1:LGPSSWITCH") {
  field(DOL1, "MGNT:COL0:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:LGPSCTRL")
}

record(seq, "MGNT:COL0:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:LGPSCTRL",20,10,0,0,"MGNT:COL0:1:LGPSCTRL")
#! Field("MGNT:COL0:1:LGPSCTRL.FLNK",16777215,1,"MGNT:COL0:1:LGPSCTRL.FLNK")
#! Link("MGNT:COL0:1:LGPSCTRL.FLNK","MGNT:COL0:1:LGPSSWITCH")
#! Field("MGNT:COL0:1:LGPSCTRL.FFVL",16777215,1,"MGNT:COL0:1:LGPSCTRL.FFVL")
#! Record("MGNT:COL0:1:LGPSSWITCH",460,322,0,0,"MGNT:COL0:1:LGPSSWITCH")
#! Field("MGNT:COL0:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:COL0:1:LGPSSWITCH.DOL1")
#! Link("MGNT:COL0:1:LGPSSWITCH.DOL1","MGNT:COL0:1:LGPSCTRL.FFVL")
#! Field("MGNT:COL0:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:COL0:1:LGPSSWITCH.LNK1")
#! Field("MGNT:COL0:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:COL0:1:LGPSSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLLGPSSGO",240,96,0,0,"MGNT:COL0:1:ALLLGPSSGO")
#! Field("MGNT:COL0:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:COL0:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:COL0:1:ALLLGPSSGO.LNK1","MGNT:COL0:1:ALLLGPSS.VAL")
#! Record("MGNT:COL0:1:ALLLGPSS",540,102,0,0,"MGNT:COL0:1:ALLLGPSS")
#! Field("MGNT:COL0:1:ALLLGPSS.VAL",16777215,0,"MGNT:COL0:1:ALLLGPSS.VAL")
#! Field("MGNT:COL0:1:ALLLGPSS.FLNK",16777215,1,"MGNT:COL0:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:COL0:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:COL0:1:QUADSWITCH")
}

record(seq, "MGNT:COL0:1:QUADSWITCH") {
  field(DOL1, "MGNT:COL0:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:QUADCTRL")
}

record(seq, "MGNT:COL0:1:ALLQUADSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:QUADCTRL",20,10,0,0,"MGNT:COL0:1:QUADCTRL")
#! Field("MGNT:COL0:1:QUADCTRL.FLNK",16777215,1,"MGNT:COL0:1:QUADCTRL.FLNK")
#! Link("MGNT:COL0:1:QUADCTRL.FLNK","MGNT:COL0:1:QUADSWITCH")
#! Field("MGNT:COL0:1:QUADCTRL.FFVL",16777215,1,"MGNT:COL0:1:QUADCTRL.FFVL")
#! Record("MGNT:COL0:1:QUADSWITCH",460,322,0,0,"MGNT:COL0:1:QUADSWITCH")
#! Field("MGNT:COL0:1:QUADSWITCH.DOL1",16777215,0,"MGNT:COL0:1:QUADSWITCH.DOL1")
#! Link("MGNT:COL0:1:QUADSWITCH.DOL1","MGNT:COL0:1:QUADCTRL.FFVL")
#! Field("MGNT:COL0:1:QUADSWITCH.LNK1",16777215,1,"MGNT:COL0:1:QUADSWITCH.LNK1")
#! Field("MGNT:COL0:1:QUADSWITCH.FLNK",16777215,1,"MGNT:COL0:1:QUADSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLQUADSGO",240,96,0,0,"MGNT:COL0:1:ALLQUADSGO")
#! Field("MGNT:COL0:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLQUADSGO.DOL1")
#! Field("MGNT:COL0:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLQUADSGO.LNK1")
#! Link("MGNT:COL0:1:ALLQUADSGO.LNK1","MGNT:COL0:1:ALLQUADS.VAL")
#! Record("MGNT:COL0:1:ALLQUADS",540,102,0,0,"MGNT:COL0:1:ALLQUADS")
#! Field("MGNT:COL0:1:ALLQUADS.VAL",16777215,0,"MGNT:COL0:1:ALLQUADS.VAL")
#! Field("MGNT:COL0:1:ALLQUADS.FLNK",16777215,1,"MGNT:COL0:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:COL0:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:COL0:1:XCORSWITCH")
}

record(seq, "MGNT:COL0:1:XCORSWITCH") {
  field(DOL1, "MGNT:COL0:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:XCORCTRL")
}

record(seq, "MGNT:COL0:1:ALLXCORSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:XCORCTRL",20,10,0,0,"MGNT:COL0:1:XCORCTRL")
#! Field("MGNT:COL0:1:XCORCTRL.FLNK",16777215,1,"MGNT:COL0:1:XCORCTRL.FLNK")
#! Link("MGNT:COL0:1:XCORCTRL.FLNK","MGNT:COL0:1:XCORSWITCH")
#! Field("MGNT:COL0:1:XCORCTRL.FFVL",16777215,1,"MGNT:COL0:1:XCORCTRL.FFVL")
#! Record("MGNT:COL0:1:XCORSWITCH",460,322,0,0,"MGNT:COL0:1:XCORSWITCH")
#! Field("MGNT:COL0:1:XCORSWITCH.DOL1",16777215,0,"MGNT:COL0:1:XCORSWITCH.DOL1")
#! Link("MGNT:COL0:1:XCORSWITCH.DOL1","MGNT:COL0:1:XCORCTRL.FFVL")
#! Field("MGNT:COL0:1:XCORSWITCH.LNK1",16777215,1,"MGNT:COL0:1:XCORSWITCH.LNK1")
#! Field("MGNT:COL0:1:XCORSWITCH.FLNK",16777215,1,"MGNT:COL0:1:XCORSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLXCORSGO",240,96,0,0,"MGNT:COL0:1:ALLXCORSGO")
#! Field("MGNT:COL0:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLXCORSGO.DOL1")
#! Field("MGNT:COL0:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLXCORSGO.LNK1")
#! Link("MGNT:COL0:1:ALLXCORSGO.LNK1","MGNT:COL0:1:ALLXCORS.VAL")
#! Record("MGNT:COL0:1:ALLXCORS",540,102,0,0,"MGNT:COL0:1:ALLXCORS")
#! Field("MGNT:COL0:1:ALLXCORS.VAL",16777215,0,"MGNT:COL0:1:ALLXCORS.VAL")
#! Field("MGNT:COL0:1:ALLXCORS.FLNK",16777215,1,"MGNT:COL0:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:COL0:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:COL0:1:YCORSWITCH")
}

record(seq, "MGNT:COL0:1:YCORSWITCH") {
  field(DOL1, "MGNT:COL0:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:YCORCTRL")
}

record(seq, "MGNT:COL0:1:ALLYCORSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:YCORCTRL",20,10,0,0,"MGNT:COL0:1:YCORCTRL")
#! Field("MGNT:COL0:1:YCORCTRL.FLNK",16777215,1,"MGNT:COL0:1:YCORCTRL.FLNK")
#! Link("MGNT:COL0:1:YCORCTRL.FLNK","MGNT:COL0:1:YCORSWITCH")
#! Field("MGNT:COL0:1:YCORCTRL.FFVL",16777215,1,"MGNT:COL0:1:YCORCTRL.FFVL")
#! Record("MGNT:COL0:1:YCORSWITCH",460,322,0,0,"MGNT:COL0:1:YCORSWITCH")
#! Field("MGNT:COL0:1:YCORSWITCH.DOL1",16777215,0,"MGNT:COL0:1:YCORSWITCH.DOL1")
#! Link("MGNT:COL0:1:YCORSWITCH.DOL1","MGNT:COL0:1:YCORCTRL.FFVL")
#! Field("MGNT:COL0:1:YCORSWITCH.LNK1",16777215,1,"MGNT:COL0:1:YCORSWITCH.LNK1")
#! Field("MGNT:COL0:1:YCORSWITCH.FLNK",16777215,1,"MGNT:COL0:1:YCORSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLYCORSGO",240,96,0,0,"MGNT:COL0:1:ALLYCORSGO")
#! Field("MGNT:COL0:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLYCORSGO.DOL1")
#! Field("MGNT:COL0:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLYCORSGO.LNK1")
#! Link("MGNT:COL0:1:ALLYCORSGO.LNK1","MGNT:COL0:1:ALLYCORS.VAL")
#! Record("MGNT:COL0:1:ALLYCORS",540,102,0,0,"MGNT:COL0:1:ALLYCORS")
#! Field("MGNT:COL0:1:ALLYCORS.VAL",16777215,0,"MGNT:COL0:1:ALLYCORS.VAL")
#! Field("MGNT:COL0:1:ALLYCORS.FLNK",16777215,1,"MGNT:COL0:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:COL0:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:COL0:1:SOLNSWITCH")
}

record(seq, "MGNT:COL0:1:SOLNSWITCH") {
  field(DOL1, "MGNT:COL0:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:SOLNCTRL")
}

record(seq, "MGNT:COL0:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:SOLNCTRL",20,10,0,0,"MGNT:COL0:1:SOLNCTRL")
#! Field("MGNT:COL0:1:SOLNCTRL.FLNK",16777215,1,"MGNT:COL0:1:SOLNCTRL.FLNK")
#! Link("MGNT:COL0:1:SOLNCTRL.FLNK","MGNT:COL0:1:SOLNSWITCH")
#! Field("MGNT:COL0:1:SOLNCTRL.FFVL",16777215,1,"MGNT:COL0:1:SOLNCTRL.FFVL")
#! Record("MGNT:COL0:1:SOLNSWITCH",460,322,0,0,"MGNT:COL0:1:SOLNSWITCH")
#! Field("MGNT:COL0:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:COL0:1:SOLNSWITCH.DOL1")
#! Link("MGNT:COL0:1:SOLNSWITCH.DOL1","MGNT:COL0:1:SOLNCTRL.FFVL")
#! Field("MGNT:COL0:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:COL0:1:SOLNSWITCH.LNK1")
#! Field("MGNT:COL0:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:COL0:1:SOLNSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLSOLNSGO",240,96,0,0,"MGNT:COL0:1:ALLSOLNSGO")
#! Field("MGNT:COL0:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:COL0:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:COL0:1:ALLSOLNSGO.LNK1","MGNT:COL0:1:ALLSOLNS.VAL")
#! Record("MGNT:COL0:1:ALLSOLNS",540,102,0,0,"MGNT:COL0:1:ALLSOLNS")
#! Field("MGNT:COL0:1:ALLSOLNS.VAL",16777215,0,"MGNT:COL0:1:ALLSOLNS.VAL")
#! Field("MGNT:COL0:1:ALLSOLNS.FLNK",16777215,1,"MGNT:COL0:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:COL0:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:COL0:1:KICKSWITCH")
}

record(seq, "MGNT:COL0:1:KICKSWITCH") {
  field(DOL1, "MGNT:COL0:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:KICKCTRL")
}

record(seq, "MGNT:COL0:1:ALLKICKSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:KICKCTRL",20,10,0,0,"MGNT:COL0:1:KICKCTRL")
#! Field("MGNT:COL0:1:KICKCTRL.FLNK",16777215,1,"MGNT:COL0:1:KICKCTRL.FLNK")
#! Link("MGNT:COL0:1:KICKCTRL.FLNK","MGNT:COL0:1:KICKSWITCH")
#! Field("MGNT:COL0:1:KICKCTRL.FFVL",16777215,1,"MGNT:COL0:1:KICKCTRL.FFVL")
#! Record("MGNT:COL0:1:KICKSWITCH",460,322,0,0,"MGNT:COL0:1:KICKSWITCH")
#! Field("MGNT:COL0:1:KICKSWITCH.DOL1",16777215,0,"MGNT:COL0:1:KICKSWITCH.DOL1")
#! Link("MGNT:COL0:1:KICKSWITCH.DOL1","MGNT:COL0:1:KICKCTRL.FFVL")
#! Field("MGNT:COL0:1:KICKSWITCH.LNK1",16777215,1,"MGNT:COL0:1:KICKSWITCH.LNK1")
#! Field("MGNT:COL0:1:KICKSWITCH.FLNK",16777215,1,"MGNT:COL0:1:KICKSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLKICKSGO",240,96,0,0,"MGNT:COL0:1:ALLKICKSGO")
#! Field("MGNT:COL0:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLKICKSGO.DOL1")
#! Field("MGNT:COL0:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLKICKSGO.LNK1")
#! Link("MGNT:COL0:1:ALLKICKSGO.LNK1","MGNT:COL0:1:ALLKICKS.VAL")
#! Record("MGNT:COL0:1:ALLKICKS",540,102,0,0,"MGNT:COL0:1:ALLKICKS")
#! Field("MGNT:COL0:1:ALLKICKS.VAL",16777215,0,"MGNT:COL0:1:ALLKICKS.VAL")
#! Field("MGNT:COL0:1:ALLKICKS.FLNK",16777215,1,"MGNT:COL0:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:COL0:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:COL0:1:SEXTSWITCH")
}

record(seq, "MGNT:COL0:1:SEXTSWITCH") {
  field(DOL1, "MGNT:COL0:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:COL0:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL0:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL0:1:SEXTCTRL")
}

record(seq, "MGNT:COL0:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:COL0:1:ALLSTAR")
  field(LNK1, "MGNT:COL0:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:COL0:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL0:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL0:1:SEXTCTRL",20,10,0,0,"MGNT:COL0:1:SEXTCTRL")
#! Field("MGNT:COL0:1:SEXTCTRL.FLNK",16777215,1,"MGNT:COL0:1:SEXTCTRL.FLNK")
#! Link("MGNT:COL0:1:SEXTCTRL.FLNK","MGNT:COL0:1:SEXTSWITCH")
#! Field("MGNT:COL0:1:SEXTCTRL.FFVL",16777215,1,"MGNT:COL0:1:SEXTCTRL.FFVL")
#! Record("MGNT:COL0:1:SEXTSWITCH",460,322,0,0,"MGNT:COL0:1:SEXTSWITCH")
#! Field("MGNT:COL0:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:COL0:1:SEXTSWITCH.DOL1")
#! Link("MGNT:COL0:1:SEXTSWITCH.DOL1","MGNT:COL0:1:SEXTCTRL.FFVL")
#! Field("MGNT:COL0:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:COL0:1:SEXTSWITCH.LNK1")
#! Field("MGNT:COL0:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:COL0:1:SEXTSWITCH.FLNK")
#! Record("MGNT:COL0:1:ALLSEXTSGO",240,96,0,0,"MGNT:COL0:1:ALLSEXTSGO")
#! Field("MGNT:COL0:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:COL0:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:COL0:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:COL0:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:COL0:1:ALLSEXTSGO.LNK1","MGNT:COL0:1:ALLSEXTS.VAL")
#! Record("MGNT:COL0:1:ALLSEXTS",540,102,0,0,"MGNT:COL0:1:ALLSEXTS")
#! Field("MGNT:COL0:1:ALLSEXTS.VAL",16777215,0,"MGNT:COL0:1:ALLSEXTS.VAL")
#! Field("MGNT:COL0:1:ALLSEXTS.FLNK",16777215,1,"MGNT:COL0:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:BC1B:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:BC1B:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:BC1B:1:CTRL CA PP")
  field(LNK2, "MGNT:BC1B:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:BC1B:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:BC1B:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:BC1B:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:BC1B:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:BC1B:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:BC1B:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:BC1B:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:BC1B:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:BC1B:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:BC1B:1:ALLSWITCH")
}

record(seq, "MGNT:BC1B:1:ALLSWITCH") {
  field(DOL1, "MGNT:BC1B:1:CTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:CTRL")
}

record(bo, "MGNT:BC1B:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLSTARGO")
}

record(fanout, "MGNT:BC1B:1:ALLSTARGO") {
  field(LNK1, "MGNT:BC1B:1:ALLBENDSGO")
  field(LNK2, "MGNT:BC1B:1:ALLBTRMSGO")
  field(LNK3, "MGNT:BC1B:1:ALLLGPSSGO")
  field(LNK4, "MGNT:BC1B:1:ALLQUADSGO")
  field(LNK5, "MGNT:BC1B:1:ALLXCORSGO")
  field(LNK6, "MGNT:BC1B:1:ALLYCORSGO")
  field(FLNK, "MGNT:BC1B:1:ALLSTARGO_2")
}
record(fanout, "MGNT:BC1B:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:BC1B:1:ALLSOLNSGO")
  field(LNK2, "MGNT:BC1B:1:ALLKICKSGO")
  field(LNK3, "MGNT:BC1B:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:BC1B:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:BC1B:1:BENDSWITCH")
}

record(seq, "MGNT:BC1B:1:BENDSWITCH") {
  field(DOL1, "MGNT:BC1B:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:BENDCTRL")
}

record(seq, "MGNT:BC1B:1:ALLBENDSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:BENDCTRL",20,10,0,0,"MGNT:BC1B:1:BENDCTRL")
#! Field("MGNT:BC1B:1:BENDCTRL.FLNK",16777215,1,"MGNT:BC1B:1:BENDCTRL.FLNK")
#! Link("MGNT:BC1B:1:BENDCTRL.FLNK","MGNT:BC1B:1:BENDSWITCH")
#! Field("MGNT:BC1B:1:BENDCTRL.FFVL",16777215,1,"MGNT:BC1B:1:BENDCTRL.FFVL")
#! Record("MGNT:BC1B:1:BENDSWITCH",460,322,0,0,"MGNT:BC1B:1:BENDSWITCH")
#! Field("MGNT:BC1B:1:BENDSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:BENDSWITCH.DOL1")
#! Link("MGNT:BC1B:1:BENDSWITCH.DOL1","MGNT:BC1B:1:BENDCTRL.FFVL")
#! Field("MGNT:BC1B:1:BENDSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:BENDSWITCH.LNK1")
#! Field("MGNT:BC1B:1:BENDSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:BENDSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLBENDSGO",240,96,0,0,"MGNT:BC1B:1:ALLBENDSGO")
#! Field("MGNT:BC1B:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLBENDSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLBENDSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLBENDSGO.LNK1","MGNT:BC1B:1:ALLBENDS.VAL")
#! Record("MGNT:BC1B:1:ALLBENDS",540,102,0,0,"MGNT:BC1B:1:ALLBENDS")
#! Field("MGNT:BC1B:1:ALLBENDS.VAL",16777215,0,"MGNT:BC1B:1:ALLBENDS.VAL")
#! Field("MGNT:BC1B:1:ALLBENDS.FLNK",16777215,1,"MGNT:BC1B:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:BC1B:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BC1B:1:BTRMSWITCH")
}

record(seq, "MGNT:BC1B:1:BTRMSWITCH") {
  field(DOL1, "MGNT:BC1B:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:BTRMCTRL")
}

record(seq, "MGNT:BC1B:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:BTRMCTRL",20,10,0,0,"MGNT:BC1B:1:BTRMCTRL")
#! Field("MGNT:BC1B:1:BTRMCTRL.FLNK",16777215,1,"MGNT:BC1B:1:BTRMCTRL.FLNK")
#! Link("MGNT:BC1B:1:BTRMCTRL.FLNK","MGNT:BC1B:1:BTRMSWITCH")
#! Field("MGNT:BC1B:1:BTRMCTRL.FFVL",16777215,1,"MGNT:BC1B:1:BTRMCTRL.FFVL")
#! Record("MGNT:BC1B:1:BTRMSWITCH",460,322,0,0,"MGNT:BC1B:1:BTRMSWITCH")
#! Field("MGNT:BC1B:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:BTRMSWITCH.DOL1")
#! Link("MGNT:BC1B:1:BTRMSWITCH.DOL1","MGNT:BC1B:1:BTRMCTRL.FFVL")
#! Field("MGNT:BC1B:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:BTRMSWITCH.LNK1")
#! Field("MGNT:BC1B:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:BTRMSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLBTRMSGO",240,96,0,0,"MGNT:BC1B:1:ALLBTRMSGO")
#! Field("MGNT:BC1B:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLBTRMSGO.LNK1","MGNT:BC1B:1:ALLBTRMS.VAL")
#! Record("MGNT:BC1B:1:ALLBTRMS",540,102,0,0,"MGNT:BC1B:1:ALLBTRMS")
#! Field("MGNT:BC1B:1:ALLBTRMS.VAL",16777215,0,"MGNT:BC1B:1:ALLBTRMS.VAL")
#! Field("MGNT:BC1B:1:ALLBTRMS.FLNK",16777215,1,"MGNT:BC1B:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:BC1B:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BC1B:1:LGPSSWITCH")
}

record(seq, "MGNT:BC1B:1:LGPSSWITCH") {
  field(DOL1, "MGNT:BC1B:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:LGPSCTRL")
}

record(seq, "MGNT:BC1B:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:LGPSCTRL",20,10,0,0,"MGNT:BC1B:1:LGPSCTRL")
#! Field("MGNT:BC1B:1:LGPSCTRL.FLNK",16777215,1,"MGNT:BC1B:1:LGPSCTRL.FLNK")
#! Link("MGNT:BC1B:1:LGPSCTRL.FLNK","MGNT:BC1B:1:LGPSSWITCH")
#! Field("MGNT:BC1B:1:LGPSCTRL.FFVL",16777215,1,"MGNT:BC1B:1:LGPSCTRL.FFVL")
#! Record("MGNT:BC1B:1:LGPSSWITCH",460,322,0,0,"MGNT:BC1B:1:LGPSSWITCH")
#! Field("MGNT:BC1B:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:LGPSSWITCH.DOL1")
#! Link("MGNT:BC1B:1:LGPSSWITCH.DOL1","MGNT:BC1B:1:LGPSCTRL.FFVL")
#! Field("MGNT:BC1B:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:LGPSSWITCH.LNK1")
#! Field("MGNT:BC1B:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:LGPSSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLLGPSSGO",240,96,0,0,"MGNT:BC1B:1:ALLLGPSSGO")
#! Field("MGNT:BC1B:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLLGPSSGO.LNK1","MGNT:BC1B:1:ALLLGPSS.VAL")
#! Record("MGNT:BC1B:1:ALLLGPSS",540,102,0,0,"MGNT:BC1B:1:ALLLGPSS")
#! Field("MGNT:BC1B:1:ALLLGPSS.VAL",16777215,0,"MGNT:BC1B:1:ALLLGPSS.VAL")
#! Field("MGNT:BC1B:1:ALLLGPSS.FLNK",16777215,1,"MGNT:BC1B:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:BC1B:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:BC1B:1:QUADSWITCH")
}

record(seq, "MGNT:BC1B:1:QUADSWITCH") {
  field(DOL1, "MGNT:BC1B:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:QUADCTRL")
}

record(seq, "MGNT:BC1B:1:ALLQUADSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:QUADCTRL",20,10,0,0,"MGNT:BC1B:1:QUADCTRL")
#! Field("MGNT:BC1B:1:QUADCTRL.FLNK",16777215,1,"MGNT:BC1B:1:QUADCTRL.FLNK")
#! Link("MGNT:BC1B:1:QUADCTRL.FLNK","MGNT:BC1B:1:QUADSWITCH")
#! Field("MGNT:BC1B:1:QUADCTRL.FFVL",16777215,1,"MGNT:BC1B:1:QUADCTRL.FFVL")
#! Record("MGNT:BC1B:1:QUADSWITCH",460,322,0,0,"MGNT:BC1B:1:QUADSWITCH")
#! Field("MGNT:BC1B:1:QUADSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:QUADSWITCH.DOL1")
#! Link("MGNT:BC1B:1:QUADSWITCH.DOL1","MGNT:BC1B:1:QUADCTRL.FFVL")
#! Field("MGNT:BC1B:1:QUADSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:QUADSWITCH.LNK1")
#! Field("MGNT:BC1B:1:QUADSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:QUADSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLQUADSGO",240,96,0,0,"MGNT:BC1B:1:ALLQUADSGO")
#! Field("MGNT:BC1B:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLQUADSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLQUADSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLQUADSGO.LNK1","MGNT:BC1B:1:ALLQUADS.VAL")
#! Record("MGNT:BC1B:1:ALLQUADS",540,102,0,0,"MGNT:BC1B:1:ALLQUADS")
#! Field("MGNT:BC1B:1:ALLQUADS.VAL",16777215,0,"MGNT:BC1B:1:ALLQUADS.VAL")
#! Field("MGNT:BC1B:1:ALLQUADS.FLNK",16777215,1,"MGNT:BC1B:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:BC1B:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:BC1B:1:XCORSWITCH")
}

record(seq, "MGNT:BC1B:1:XCORSWITCH") {
  field(DOL1, "MGNT:BC1B:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:XCORCTRL")
}

record(seq, "MGNT:BC1B:1:ALLXCORSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:XCORCTRL",20,10,0,0,"MGNT:BC1B:1:XCORCTRL")
#! Field("MGNT:BC1B:1:XCORCTRL.FLNK",16777215,1,"MGNT:BC1B:1:XCORCTRL.FLNK")
#! Link("MGNT:BC1B:1:XCORCTRL.FLNK","MGNT:BC1B:1:XCORSWITCH")
#! Field("MGNT:BC1B:1:XCORCTRL.FFVL",16777215,1,"MGNT:BC1B:1:XCORCTRL.FFVL")
#! Record("MGNT:BC1B:1:XCORSWITCH",460,322,0,0,"MGNT:BC1B:1:XCORSWITCH")
#! Field("MGNT:BC1B:1:XCORSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:XCORSWITCH.DOL1")
#! Link("MGNT:BC1B:1:XCORSWITCH.DOL1","MGNT:BC1B:1:XCORCTRL.FFVL")
#! Field("MGNT:BC1B:1:XCORSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:XCORSWITCH.LNK1")
#! Field("MGNT:BC1B:1:XCORSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:XCORSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLXCORSGO",240,96,0,0,"MGNT:BC1B:1:ALLXCORSGO")
#! Field("MGNT:BC1B:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLXCORSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLXCORSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLXCORSGO.LNK1","MGNT:BC1B:1:ALLXCORS.VAL")
#! Record("MGNT:BC1B:1:ALLXCORS",540,102,0,0,"MGNT:BC1B:1:ALLXCORS")
#! Field("MGNT:BC1B:1:ALLXCORS.VAL",16777215,0,"MGNT:BC1B:1:ALLXCORS.VAL")
#! Field("MGNT:BC1B:1:ALLXCORS.FLNK",16777215,1,"MGNT:BC1B:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:BC1B:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:BC1B:1:YCORSWITCH")
}

record(seq, "MGNT:BC1B:1:YCORSWITCH") {
  field(DOL1, "MGNT:BC1B:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:YCORCTRL")
}

record(seq, "MGNT:BC1B:1:ALLYCORSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:YCORCTRL",20,10,0,0,"MGNT:BC1B:1:YCORCTRL")
#! Field("MGNT:BC1B:1:YCORCTRL.FLNK",16777215,1,"MGNT:BC1B:1:YCORCTRL.FLNK")
#! Link("MGNT:BC1B:1:YCORCTRL.FLNK","MGNT:BC1B:1:YCORSWITCH")
#! Field("MGNT:BC1B:1:YCORCTRL.FFVL",16777215,1,"MGNT:BC1B:1:YCORCTRL.FFVL")
#! Record("MGNT:BC1B:1:YCORSWITCH",460,322,0,0,"MGNT:BC1B:1:YCORSWITCH")
#! Field("MGNT:BC1B:1:YCORSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:YCORSWITCH.DOL1")
#! Link("MGNT:BC1B:1:YCORSWITCH.DOL1","MGNT:BC1B:1:YCORCTRL.FFVL")
#! Field("MGNT:BC1B:1:YCORSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:YCORSWITCH.LNK1")
#! Field("MGNT:BC1B:1:YCORSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:YCORSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLYCORSGO",240,96,0,0,"MGNT:BC1B:1:ALLYCORSGO")
#! Field("MGNT:BC1B:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLYCORSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLYCORSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLYCORSGO.LNK1","MGNT:BC1B:1:ALLYCORS.VAL")
#! Record("MGNT:BC1B:1:ALLYCORS",540,102,0,0,"MGNT:BC1B:1:ALLYCORS")
#! Field("MGNT:BC1B:1:ALLYCORS.VAL",16777215,0,"MGNT:BC1B:1:ALLYCORS.VAL")
#! Field("MGNT:BC1B:1:ALLYCORS.FLNK",16777215,1,"MGNT:BC1B:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:BC1B:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:BC1B:1:SOLNSWITCH")
}

record(seq, "MGNT:BC1B:1:SOLNSWITCH") {
  field(DOL1, "MGNT:BC1B:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:SOLNCTRL")
}

record(seq, "MGNT:BC1B:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:SOLNCTRL",20,10,0,0,"MGNT:BC1B:1:SOLNCTRL")
#! Field("MGNT:BC1B:1:SOLNCTRL.FLNK",16777215,1,"MGNT:BC1B:1:SOLNCTRL.FLNK")
#! Link("MGNT:BC1B:1:SOLNCTRL.FLNK","MGNT:BC1B:1:SOLNSWITCH")
#! Field("MGNT:BC1B:1:SOLNCTRL.FFVL",16777215,1,"MGNT:BC1B:1:SOLNCTRL.FFVL")
#! Record("MGNT:BC1B:1:SOLNSWITCH",460,322,0,0,"MGNT:BC1B:1:SOLNSWITCH")
#! Field("MGNT:BC1B:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:SOLNSWITCH.DOL1")
#! Link("MGNT:BC1B:1:SOLNSWITCH.DOL1","MGNT:BC1B:1:SOLNCTRL.FFVL")
#! Field("MGNT:BC1B:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:SOLNSWITCH.LNK1")
#! Field("MGNT:BC1B:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:SOLNSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLSOLNSGO",240,96,0,0,"MGNT:BC1B:1:ALLSOLNSGO")
#! Field("MGNT:BC1B:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLSOLNSGO.LNK1","MGNT:BC1B:1:ALLSOLNS.VAL")
#! Record("MGNT:BC1B:1:ALLSOLNS",540,102,0,0,"MGNT:BC1B:1:ALLSOLNS")
#! Field("MGNT:BC1B:1:ALLSOLNS.VAL",16777215,0,"MGNT:BC1B:1:ALLSOLNS.VAL")
#! Field("MGNT:BC1B:1:ALLSOLNS.FLNK",16777215,1,"MGNT:BC1B:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:BC1B:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:BC1B:1:KICKSWITCH")
}

record(seq, "MGNT:BC1B:1:KICKSWITCH") {
  field(DOL1, "MGNT:BC1B:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:KICKCTRL")
}

record(seq, "MGNT:BC1B:1:ALLKICKSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:KICKCTRL",20,10,0,0,"MGNT:BC1B:1:KICKCTRL")
#! Field("MGNT:BC1B:1:KICKCTRL.FLNK",16777215,1,"MGNT:BC1B:1:KICKCTRL.FLNK")
#! Link("MGNT:BC1B:1:KICKCTRL.FLNK","MGNT:BC1B:1:KICKSWITCH")
#! Field("MGNT:BC1B:1:KICKCTRL.FFVL",16777215,1,"MGNT:BC1B:1:KICKCTRL.FFVL")
#! Record("MGNT:BC1B:1:KICKSWITCH",460,322,0,0,"MGNT:BC1B:1:KICKSWITCH")
#! Field("MGNT:BC1B:1:KICKSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:KICKSWITCH.DOL1")
#! Link("MGNT:BC1B:1:KICKSWITCH.DOL1","MGNT:BC1B:1:KICKCTRL.FFVL")
#! Field("MGNT:BC1B:1:KICKSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:KICKSWITCH.LNK1")
#! Field("MGNT:BC1B:1:KICKSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:KICKSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLKICKSGO",240,96,0,0,"MGNT:BC1B:1:ALLKICKSGO")
#! Field("MGNT:BC1B:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLKICKSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLKICKSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLKICKSGO.LNK1","MGNT:BC1B:1:ALLKICKS.VAL")
#! Record("MGNT:BC1B:1:ALLKICKS",540,102,0,0,"MGNT:BC1B:1:ALLKICKS")
#! Field("MGNT:BC1B:1:ALLKICKS.VAL",16777215,0,"MGNT:BC1B:1:ALLKICKS.VAL")
#! Field("MGNT:BC1B:1:ALLKICKS.FLNK",16777215,1,"MGNT:BC1B:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:BC1B:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:BC1B:1:SEXTSWITCH")
}

record(seq, "MGNT:BC1B:1:SEXTSWITCH") {
  field(DOL1, "MGNT:BC1B:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:BC1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC1B:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC1B:1:SEXTCTRL")
}

record(seq, "MGNT:BC1B:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:BC1B:1:ALLSTAR")
  field(LNK1, "MGNT:BC1B:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:BC1B:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC1B:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC1B:1:SEXTCTRL",20,10,0,0,"MGNT:BC1B:1:SEXTCTRL")
#! Field("MGNT:BC1B:1:SEXTCTRL.FLNK",16777215,1,"MGNT:BC1B:1:SEXTCTRL.FLNK")
#! Link("MGNT:BC1B:1:SEXTCTRL.FLNK","MGNT:BC1B:1:SEXTSWITCH")
#! Field("MGNT:BC1B:1:SEXTCTRL.FFVL",16777215,1,"MGNT:BC1B:1:SEXTCTRL.FFVL")
#! Record("MGNT:BC1B:1:SEXTSWITCH",460,322,0,0,"MGNT:BC1B:1:SEXTSWITCH")
#! Field("MGNT:BC1B:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:BC1B:1:SEXTSWITCH.DOL1")
#! Link("MGNT:BC1B:1:SEXTSWITCH.DOL1","MGNT:BC1B:1:SEXTCTRL.FFVL")
#! Field("MGNT:BC1B:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:BC1B:1:SEXTSWITCH.LNK1")
#! Field("MGNT:BC1B:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:BC1B:1:SEXTSWITCH.FLNK")
#! Record("MGNT:BC1B:1:ALLSEXTSGO",240,96,0,0,"MGNT:BC1B:1:ALLSEXTSGO")
#! Field("MGNT:BC1B:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:BC1B:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:BC1B:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:BC1B:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:BC1B:1:ALLSEXTSGO.LNK1","MGNT:BC1B:1:ALLSEXTS.VAL")
#! Record("MGNT:BC1B:1:ALLSEXTS",540,102,0,0,"MGNT:BC1B:1:ALLSEXTS")
#! Field("MGNT:BC1B:1:ALLSEXTS.VAL",16777215,0,"MGNT:BC1B:1:ALLSEXTS.VAL")
#! Field("MGNT:BC1B:1:ALLSEXTS.FLNK",16777215,1,"MGNT:BC1B:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:COL1:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:COL1:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:COL1:1:CTRL CA PP")
  field(LNK2, "MGNT:COL1:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:COL1:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:COL1:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:COL1:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:COL1:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:COL1:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:COL1:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:COL1:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:COL1:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:COL1:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:COL1:1:ALLSWITCH")
}

record(seq, "MGNT:COL1:1:ALLSWITCH") {
  field(DOL1, "MGNT:COL1:1:CTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:CTRL")
}

record(bo, "MGNT:COL1:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:COL1:1:ALLSTARGO")
}

record(fanout, "MGNT:COL1:1:ALLSTARGO") {
  field(LNK1, "MGNT:COL1:1:ALLBENDSGO")
  field(LNK2, "MGNT:COL1:1:ALLBTRMSGO")
  field(LNK3, "MGNT:COL1:1:ALLLGPSSGO")
  field(LNK4, "MGNT:COL1:1:ALLQUADSGO")
  field(LNK5, "MGNT:COL1:1:ALLXCORSGO")
  field(LNK6, "MGNT:COL1:1:ALLYCORSGO")
  field(FLNK, "MGNT:COL1:1:ALLSTARGO_2")
}
record(fanout, "MGNT:COL1:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:COL1:1:ALLSOLNSGO")
  field(LNK2, "MGNT:COL1:1:ALLKICKSGO")
  field(LNK3, "MGNT:COL1:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:COL1:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:COL1:1:BENDSWITCH")
}

record(seq, "MGNT:COL1:1:BENDSWITCH") {
  field(DOL1, "MGNT:COL1:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:BENDCTRL")
}

record(seq, "MGNT:COL1:1:ALLBENDSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:BENDCTRL",20,10,0,0,"MGNT:COL1:1:BENDCTRL")
#! Field("MGNT:COL1:1:BENDCTRL.FLNK",16777215,1,"MGNT:COL1:1:BENDCTRL.FLNK")
#! Link("MGNT:COL1:1:BENDCTRL.FLNK","MGNT:COL1:1:BENDSWITCH")
#! Field("MGNT:COL1:1:BENDCTRL.FFVL",16777215,1,"MGNT:COL1:1:BENDCTRL.FFVL")
#! Record("MGNT:COL1:1:BENDSWITCH",460,322,0,0,"MGNT:COL1:1:BENDSWITCH")
#! Field("MGNT:COL1:1:BENDSWITCH.DOL1",16777215,0,"MGNT:COL1:1:BENDSWITCH.DOL1")
#! Link("MGNT:COL1:1:BENDSWITCH.DOL1","MGNT:COL1:1:BENDCTRL.FFVL")
#! Field("MGNT:COL1:1:BENDSWITCH.LNK1",16777215,1,"MGNT:COL1:1:BENDSWITCH.LNK1")
#! Field("MGNT:COL1:1:BENDSWITCH.FLNK",16777215,1,"MGNT:COL1:1:BENDSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLBENDSGO",240,96,0,0,"MGNT:COL1:1:ALLBENDSGO")
#! Field("MGNT:COL1:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLBENDSGO.DOL1")
#! Field("MGNT:COL1:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLBENDSGO.LNK1")
#! Link("MGNT:COL1:1:ALLBENDSGO.LNK1","MGNT:COL1:1:ALLBENDS.VAL")
#! Record("MGNT:COL1:1:ALLBENDS",540,102,0,0,"MGNT:COL1:1:ALLBENDS")
#! Field("MGNT:COL1:1:ALLBENDS.VAL",16777215,0,"MGNT:COL1:1:ALLBENDS.VAL")
#! Field("MGNT:COL1:1:ALLBENDS.FLNK",16777215,1,"MGNT:COL1:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:COL1:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:COL1:1:BTRMSWITCH")
}

record(seq, "MGNT:COL1:1:BTRMSWITCH") {
  field(DOL1, "MGNT:COL1:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:BTRMCTRL")
}

record(seq, "MGNT:COL1:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:BTRMCTRL",20,10,0,0,"MGNT:COL1:1:BTRMCTRL")
#! Field("MGNT:COL1:1:BTRMCTRL.FLNK",16777215,1,"MGNT:COL1:1:BTRMCTRL.FLNK")
#! Link("MGNT:COL1:1:BTRMCTRL.FLNK","MGNT:COL1:1:BTRMSWITCH")
#! Field("MGNT:COL1:1:BTRMCTRL.FFVL",16777215,1,"MGNT:COL1:1:BTRMCTRL.FFVL")
#! Record("MGNT:COL1:1:BTRMSWITCH",460,322,0,0,"MGNT:COL1:1:BTRMSWITCH")
#! Field("MGNT:COL1:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:COL1:1:BTRMSWITCH.DOL1")
#! Link("MGNT:COL1:1:BTRMSWITCH.DOL1","MGNT:COL1:1:BTRMCTRL.FFVL")
#! Field("MGNT:COL1:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:COL1:1:BTRMSWITCH.LNK1")
#! Field("MGNT:COL1:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:COL1:1:BTRMSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLBTRMSGO",240,96,0,0,"MGNT:COL1:1:ALLBTRMSGO")
#! Field("MGNT:COL1:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:COL1:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:COL1:1:ALLBTRMSGO.LNK1","MGNT:COL1:1:ALLBTRMS.VAL")
#! Record("MGNT:COL1:1:ALLBTRMS",540,102,0,0,"MGNT:COL1:1:ALLBTRMS")
#! Field("MGNT:COL1:1:ALLBTRMS.VAL",16777215,0,"MGNT:COL1:1:ALLBTRMS.VAL")
#! Field("MGNT:COL1:1:ALLBTRMS.FLNK",16777215,1,"MGNT:COL1:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:COL1:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:COL1:1:LGPSSWITCH")
}

record(seq, "MGNT:COL1:1:LGPSSWITCH") {
  field(DOL1, "MGNT:COL1:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:LGPSCTRL")
}

record(seq, "MGNT:COL1:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:LGPSCTRL",20,10,0,0,"MGNT:COL1:1:LGPSCTRL")
#! Field("MGNT:COL1:1:LGPSCTRL.FLNK",16777215,1,"MGNT:COL1:1:LGPSCTRL.FLNK")
#! Link("MGNT:COL1:1:LGPSCTRL.FLNK","MGNT:COL1:1:LGPSSWITCH")
#! Field("MGNT:COL1:1:LGPSCTRL.FFVL",16777215,1,"MGNT:COL1:1:LGPSCTRL.FFVL")
#! Record("MGNT:COL1:1:LGPSSWITCH",460,322,0,0,"MGNT:COL1:1:LGPSSWITCH")
#! Field("MGNT:COL1:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:COL1:1:LGPSSWITCH.DOL1")
#! Link("MGNT:COL1:1:LGPSSWITCH.DOL1","MGNT:COL1:1:LGPSCTRL.FFVL")
#! Field("MGNT:COL1:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:COL1:1:LGPSSWITCH.LNK1")
#! Field("MGNT:COL1:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:COL1:1:LGPSSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLLGPSSGO",240,96,0,0,"MGNT:COL1:1:ALLLGPSSGO")
#! Field("MGNT:COL1:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:COL1:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:COL1:1:ALLLGPSSGO.LNK1","MGNT:COL1:1:ALLLGPSS.VAL")
#! Record("MGNT:COL1:1:ALLLGPSS",540,102,0,0,"MGNT:COL1:1:ALLLGPSS")
#! Field("MGNT:COL1:1:ALLLGPSS.VAL",16777215,0,"MGNT:COL1:1:ALLLGPSS.VAL")
#! Field("MGNT:COL1:1:ALLLGPSS.FLNK",16777215,1,"MGNT:COL1:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:COL1:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:COL1:1:QUADSWITCH")
}

record(seq, "MGNT:COL1:1:QUADSWITCH") {
  field(DOL1, "MGNT:COL1:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:QUADCTRL")
}

record(seq, "MGNT:COL1:1:ALLQUADSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:QUADCTRL",20,10,0,0,"MGNT:COL1:1:QUADCTRL")
#! Field("MGNT:COL1:1:QUADCTRL.FLNK",16777215,1,"MGNT:COL1:1:QUADCTRL.FLNK")
#! Link("MGNT:COL1:1:QUADCTRL.FLNK","MGNT:COL1:1:QUADSWITCH")
#! Field("MGNT:COL1:1:QUADCTRL.FFVL",16777215,1,"MGNT:COL1:1:QUADCTRL.FFVL")
#! Record("MGNT:COL1:1:QUADSWITCH",460,322,0,0,"MGNT:COL1:1:QUADSWITCH")
#! Field("MGNT:COL1:1:QUADSWITCH.DOL1",16777215,0,"MGNT:COL1:1:QUADSWITCH.DOL1")
#! Link("MGNT:COL1:1:QUADSWITCH.DOL1","MGNT:COL1:1:QUADCTRL.FFVL")
#! Field("MGNT:COL1:1:QUADSWITCH.LNK1",16777215,1,"MGNT:COL1:1:QUADSWITCH.LNK1")
#! Field("MGNT:COL1:1:QUADSWITCH.FLNK",16777215,1,"MGNT:COL1:1:QUADSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLQUADSGO",240,96,0,0,"MGNT:COL1:1:ALLQUADSGO")
#! Field("MGNT:COL1:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLQUADSGO.DOL1")
#! Field("MGNT:COL1:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLQUADSGO.LNK1")
#! Link("MGNT:COL1:1:ALLQUADSGO.LNK1","MGNT:COL1:1:ALLQUADS.VAL")
#! Record("MGNT:COL1:1:ALLQUADS",540,102,0,0,"MGNT:COL1:1:ALLQUADS")
#! Field("MGNT:COL1:1:ALLQUADS.VAL",16777215,0,"MGNT:COL1:1:ALLQUADS.VAL")
#! Field("MGNT:COL1:1:ALLQUADS.FLNK",16777215,1,"MGNT:COL1:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:COL1:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:COL1:1:XCORSWITCH")
}

record(seq, "MGNT:COL1:1:XCORSWITCH") {
  field(DOL1, "MGNT:COL1:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:XCORCTRL")
}

record(seq, "MGNT:COL1:1:ALLXCORSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:XCORCTRL",20,10,0,0,"MGNT:COL1:1:XCORCTRL")
#! Field("MGNT:COL1:1:XCORCTRL.FLNK",16777215,1,"MGNT:COL1:1:XCORCTRL.FLNK")
#! Link("MGNT:COL1:1:XCORCTRL.FLNK","MGNT:COL1:1:XCORSWITCH")
#! Field("MGNT:COL1:1:XCORCTRL.FFVL",16777215,1,"MGNT:COL1:1:XCORCTRL.FFVL")
#! Record("MGNT:COL1:1:XCORSWITCH",460,322,0,0,"MGNT:COL1:1:XCORSWITCH")
#! Field("MGNT:COL1:1:XCORSWITCH.DOL1",16777215,0,"MGNT:COL1:1:XCORSWITCH.DOL1")
#! Link("MGNT:COL1:1:XCORSWITCH.DOL1","MGNT:COL1:1:XCORCTRL.FFVL")
#! Field("MGNT:COL1:1:XCORSWITCH.LNK1",16777215,1,"MGNT:COL1:1:XCORSWITCH.LNK1")
#! Field("MGNT:COL1:1:XCORSWITCH.FLNK",16777215,1,"MGNT:COL1:1:XCORSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLXCORSGO",240,96,0,0,"MGNT:COL1:1:ALLXCORSGO")
#! Field("MGNT:COL1:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLXCORSGO.DOL1")
#! Field("MGNT:COL1:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLXCORSGO.LNK1")
#! Link("MGNT:COL1:1:ALLXCORSGO.LNK1","MGNT:COL1:1:ALLXCORS.VAL")
#! Record("MGNT:COL1:1:ALLXCORS",540,102,0,0,"MGNT:COL1:1:ALLXCORS")
#! Field("MGNT:COL1:1:ALLXCORS.VAL",16777215,0,"MGNT:COL1:1:ALLXCORS.VAL")
#! Field("MGNT:COL1:1:ALLXCORS.FLNK",16777215,1,"MGNT:COL1:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:COL1:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:COL1:1:YCORSWITCH")
}

record(seq, "MGNT:COL1:1:YCORSWITCH") {
  field(DOL1, "MGNT:COL1:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:YCORCTRL")
}

record(seq, "MGNT:COL1:1:ALLYCORSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:YCORCTRL",20,10,0,0,"MGNT:COL1:1:YCORCTRL")
#! Field("MGNT:COL1:1:YCORCTRL.FLNK",16777215,1,"MGNT:COL1:1:YCORCTRL.FLNK")
#! Link("MGNT:COL1:1:YCORCTRL.FLNK","MGNT:COL1:1:YCORSWITCH")
#! Field("MGNT:COL1:1:YCORCTRL.FFVL",16777215,1,"MGNT:COL1:1:YCORCTRL.FFVL")
#! Record("MGNT:COL1:1:YCORSWITCH",460,322,0,0,"MGNT:COL1:1:YCORSWITCH")
#! Field("MGNT:COL1:1:YCORSWITCH.DOL1",16777215,0,"MGNT:COL1:1:YCORSWITCH.DOL1")
#! Link("MGNT:COL1:1:YCORSWITCH.DOL1","MGNT:COL1:1:YCORCTRL.FFVL")
#! Field("MGNT:COL1:1:YCORSWITCH.LNK1",16777215,1,"MGNT:COL1:1:YCORSWITCH.LNK1")
#! Field("MGNT:COL1:1:YCORSWITCH.FLNK",16777215,1,"MGNT:COL1:1:YCORSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLYCORSGO",240,96,0,0,"MGNT:COL1:1:ALLYCORSGO")
#! Field("MGNT:COL1:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLYCORSGO.DOL1")
#! Field("MGNT:COL1:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLYCORSGO.LNK1")
#! Link("MGNT:COL1:1:ALLYCORSGO.LNK1","MGNT:COL1:1:ALLYCORS.VAL")
#! Record("MGNT:COL1:1:ALLYCORS",540,102,0,0,"MGNT:COL1:1:ALLYCORS")
#! Field("MGNT:COL1:1:ALLYCORS.VAL",16777215,0,"MGNT:COL1:1:ALLYCORS.VAL")
#! Field("MGNT:COL1:1:ALLYCORS.FLNK",16777215,1,"MGNT:COL1:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:COL1:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:COL1:1:SOLNSWITCH")
}

record(seq, "MGNT:COL1:1:SOLNSWITCH") {
  field(DOL1, "MGNT:COL1:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:SOLNCTRL")
}

record(seq, "MGNT:COL1:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:SOLNCTRL",20,10,0,0,"MGNT:COL1:1:SOLNCTRL")
#! Field("MGNT:COL1:1:SOLNCTRL.FLNK",16777215,1,"MGNT:COL1:1:SOLNCTRL.FLNK")
#! Link("MGNT:COL1:1:SOLNCTRL.FLNK","MGNT:COL1:1:SOLNSWITCH")
#! Field("MGNT:COL1:1:SOLNCTRL.FFVL",16777215,1,"MGNT:COL1:1:SOLNCTRL.FFVL")
#! Record("MGNT:COL1:1:SOLNSWITCH",460,322,0,0,"MGNT:COL1:1:SOLNSWITCH")
#! Field("MGNT:COL1:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:COL1:1:SOLNSWITCH.DOL1")
#! Link("MGNT:COL1:1:SOLNSWITCH.DOL1","MGNT:COL1:1:SOLNCTRL.FFVL")
#! Field("MGNT:COL1:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:COL1:1:SOLNSWITCH.LNK1")
#! Field("MGNT:COL1:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:COL1:1:SOLNSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLSOLNSGO",240,96,0,0,"MGNT:COL1:1:ALLSOLNSGO")
#! Field("MGNT:COL1:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:COL1:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:COL1:1:ALLSOLNSGO.LNK1","MGNT:COL1:1:ALLSOLNS.VAL")
#! Record("MGNT:COL1:1:ALLSOLNS",540,102,0,0,"MGNT:COL1:1:ALLSOLNS")
#! Field("MGNT:COL1:1:ALLSOLNS.VAL",16777215,0,"MGNT:COL1:1:ALLSOLNS.VAL")
#! Field("MGNT:COL1:1:ALLSOLNS.FLNK",16777215,1,"MGNT:COL1:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:COL1:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:COL1:1:KICKSWITCH")
}

record(seq, "MGNT:COL1:1:KICKSWITCH") {
  field(DOL1, "MGNT:COL1:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:KICKCTRL")
}

record(seq, "MGNT:COL1:1:ALLKICKSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:KICKCTRL",20,10,0,0,"MGNT:COL1:1:KICKCTRL")
#! Field("MGNT:COL1:1:KICKCTRL.FLNK",16777215,1,"MGNT:COL1:1:KICKCTRL.FLNK")
#! Link("MGNT:COL1:1:KICKCTRL.FLNK","MGNT:COL1:1:KICKSWITCH")
#! Field("MGNT:COL1:1:KICKCTRL.FFVL",16777215,1,"MGNT:COL1:1:KICKCTRL.FFVL")
#! Record("MGNT:COL1:1:KICKSWITCH",460,322,0,0,"MGNT:COL1:1:KICKSWITCH")
#! Field("MGNT:COL1:1:KICKSWITCH.DOL1",16777215,0,"MGNT:COL1:1:KICKSWITCH.DOL1")
#! Link("MGNT:COL1:1:KICKSWITCH.DOL1","MGNT:COL1:1:KICKCTRL.FFVL")
#! Field("MGNT:COL1:1:KICKSWITCH.LNK1",16777215,1,"MGNT:COL1:1:KICKSWITCH.LNK1")
#! Field("MGNT:COL1:1:KICKSWITCH.FLNK",16777215,1,"MGNT:COL1:1:KICKSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLKICKSGO",240,96,0,0,"MGNT:COL1:1:ALLKICKSGO")
#! Field("MGNT:COL1:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLKICKSGO.DOL1")
#! Field("MGNT:COL1:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLKICKSGO.LNK1")
#! Link("MGNT:COL1:1:ALLKICKSGO.LNK1","MGNT:COL1:1:ALLKICKS.VAL")
#! Record("MGNT:COL1:1:ALLKICKS",540,102,0,0,"MGNT:COL1:1:ALLKICKS")
#! Field("MGNT:COL1:1:ALLKICKS.VAL",16777215,0,"MGNT:COL1:1:ALLKICKS.VAL")
#! Field("MGNT:COL1:1:ALLKICKS.FLNK",16777215,1,"MGNT:COL1:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:COL1:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:COL1:1:SEXTSWITCH")
}

record(seq, "MGNT:COL1:1:SEXTSWITCH") {
  field(DOL1, "MGNT:COL1:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:COL1:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:COL1:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:COL1:1:SEXTCTRL")
}

record(seq, "MGNT:COL1:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:COL1:1:ALLSTAR")
  field(LNK1, "MGNT:COL1:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:COL1:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:COL1:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:COL1:1:SEXTCTRL",20,10,0,0,"MGNT:COL1:1:SEXTCTRL")
#! Field("MGNT:COL1:1:SEXTCTRL.FLNK",16777215,1,"MGNT:COL1:1:SEXTCTRL.FLNK")
#! Link("MGNT:COL1:1:SEXTCTRL.FLNK","MGNT:COL1:1:SEXTSWITCH")
#! Field("MGNT:COL1:1:SEXTCTRL.FFVL",16777215,1,"MGNT:COL1:1:SEXTCTRL.FFVL")
#! Record("MGNT:COL1:1:SEXTSWITCH",460,322,0,0,"MGNT:COL1:1:SEXTSWITCH")
#! Field("MGNT:COL1:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:COL1:1:SEXTSWITCH.DOL1")
#! Link("MGNT:COL1:1:SEXTSWITCH.DOL1","MGNT:COL1:1:SEXTCTRL.FFVL")
#! Field("MGNT:COL1:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:COL1:1:SEXTSWITCH.LNK1")
#! Field("MGNT:COL1:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:COL1:1:SEXTSWITCH.FLNK")
#! Record("MGNT:COL1:1:ALLSEXTSGO",240,96,0,0,"MGNT:COL1:1:ALLSEXTSGO")
#! Field("MGNT:COL1:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:COL1:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:COL1:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:COL1:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:COL1:1:ALLSEXTSGO.LNK1","MGNT:COL1:1:ALLSEXTS.VAL")
#! Record("MGNT:COL1:1:ALLSEXTS",540,102,0,0,"MGNT:COL1:1:ALLSEXTS")
#! Field("MGNT:COL1:1:ALLSEXTS.VAL",16777215,0,"MGNT:COL1:1:ALLSEXTS.VAL")
#! Field("MGNT:COL1:1:ALLSEXTS.FLNK",16777215,1,"MGNT:COL1:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:L1B:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:L1B:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:L1B:1:CTRL CA PP")
  field(LNK2, "MGNT:L1B:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:L1B:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:L1B:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:L1B:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:L1B:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:L1B:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:L1B:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:L1B:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:L1B:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:L1B:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:L1B:1:ALLSWITCH")
}

record(seq, "MGNT:L1B:1:ALLSWITCH") {
  field(DOL1, "MGNT:L1B:1:CTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:CTRL")
}

record(bo, "MGNT:L1B:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:L1B:1:ALLSTARGO")
}

record(fanout, "MGNT:L1B:1:ALLSTARGO") {
  field(LNK1, "MGNT:L1B:1:ALLBENDSGO")
  field(LNK2, "MGNT:L1B:1:ALLBTRMSGO")
  field(LNK3, "MGNT:L1B:1:ALLLGPSSGO")
  field(LNK4, "MGNT:L1B:1:ALLQUADSGO")
  field(LNK5, "MGNT:L1B:1:ALLXCORSGO")
  field(LNK6, "MGNT:L1B:1:ALLYCORSGO")
  field(FLNK, "MGNT:L1B:1:ALLSTARGO_2")
}
record(fanout, "MGNT:L1B:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:L1B:1:ALLSOLNSGO")
  field(LNK2, "MGNT:L1B:1:ALLKICKSGO")
  field(LNK3, "MGNT:L1B:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:L1B:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:L1B:1:BENDSWITCH")
}

record(seq, "MGNT:L1B:1:BENDSWITCH") {
  field(DOL1, "MGNT:L1B:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:BENDCTRL")
}

record(seq, "MGNT:L1B:1:ALLBENDSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:BENDCTRL",20,10,0,0,"MGNT:L1B:1:BENDCTRL")
#! Field("MGNT:L1B:1:BENDCTRL.FLNK",16777215,1,"MGNT:L1B:1:BENDCTRL.FLNK")
#! Link("MGNT:L1B:1:BENDCTRL.FLNK","MGNT:L1B:1:BENDSWITCH")
#! Field("MGNT:L1B:1:BENDCTRL.FFVL",16777215,1,"MGNT:L1B:1:BENDCTRL.FFVL")
#! Record("MGNT:L1B:1:BENDSWITCH",460,322,0,0,"MGNT:L1B:1:BENDSWITCH")
#! Field("MGNT:L1B:1:BENDSWITCH.DOL1",16777215,0,"MGNT:L1B:1:BENDSWITCH.DOL1")
#! Link("MGNT:L1B:1:BENDSWITCH.DOL1","MGNT:L1B:1:BENDCTRL.FFVL")
#! Field("MGNT:L1B:1:BENDSWITCH.LNK1",16777215,1,"MGNT:L1B:1:BENDSWITCH.LNK1")
#! Field("MGNT:L1B:1:BENDSWITCH.FLNK",16777215,1,"MGNT:L1B:1:BENDSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLBENDSGO",240,96,0,0,"MGNT:L1B:1:ALLBENDSGO")
#! Field("MGNT:L1B:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLBENDSGO.DOL1")
#! Field("MGNT:L1B:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLBENDSGO.LNK1")
#! Link("MGNT:L1B:1:ALLBENDSGO.LNK1","MGNT:L1B:1:ALLBENDS.VAL")
#! Record("MGNT:L1B:1:ALLBENDS",540,102,0,0,"MGNT:L1B:1:ALLBENDS")
#! Field("MGNT:L1B:1:ALLBENDS.VAL",16777215,0,"MGNT:L1B:1:ALLBENDS.VAL")
#! Field("MGNT:L1B:1:ALLBENDS.FLNK",16777215,1,"MGNT:L1B:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:L1B:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L1B:1:BTRMSWITCH")
}

record(seq, "MGNT:L1B:1:BTRMSWITCH") {
  field(DOL1, "MGNT:L1B:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:BTRMCTRL")
}

record(seq, "MGNT:L1B:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:BTRMCTRL",20,10,0,0,"MGNT:L1B:1:BTRMCTRL")
#! Field("MGNT:L1B:1:BTRMCTRL.FLNK",16777215,1,"MGNT:L1B:1:BTRMCTRL.FLNK")
#! Link("MGNT:L1B:1:BTRMCTRL.FLNK","MGNT:L1B:1:BTRMSWITCH")
#! Field("MGNT:L1B:1:BTRMCTRL.FFVL",16777215,1,"MGNT:L1B:1:BTRMCTRL.FFVL")
#! Record("MGNT:L1B:1:BTRMSWITCH",460,322,0,0,"MGNT:L1B:1:BTRMSWITCH")
#! Field("MGNT:L1B:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:L1B:1:BTRMSWITCH.DOL1")
#! Link("MGNT:L1B:1:BTRMSWITCH.DOL1","MGNT:L1B:1:BTRMCTRL.FFVL")
#! Field("MGNT:L1B:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:L1B:1:BTRMSWITCH.LNK1")
#! Field("MGNT:L1B:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:L1B:1:BTRMSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLBTRMSGO",240,96,0,0,"MGNT:L1B:1:ALLBTRMSGO")
#! Field("MGNT:L1B:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:L1B:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:L1B:1:ALLBTRMSGO.LNK1","MGNT:L1B:1:ALLBTRMS.VAL")
#! Record("MGNT:L1B:1:ALLBTRMS",540,102,0,0,"MGNT:L1B:1:ALLBTRMS")
#! Field("MGNT:L1B:1:ALLBTRMS.VAL",16777215,0,"MGNT:L1B:1:ALLBTRMS.VAL")
#! Field("MGNT:L1B:1:ALLBTRMS.FLNK",16777215,1,"MGNT:L1B:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:L1B:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L1B:1:LGPSSWITCH")
}

record(seq, "MGNT:L1B:1:LGPSSWITCH") {
  field(DOL1, "MGNT:L1B:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:LGPSCTRL")
}

record(seq, "MGNT:L1B:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:LGPSCTRL",20,10,0,0,"MGNT:L1B:1:LGPSCTRL")
#! Field("MGNT:L1B:1:LGPSCTRL.FLNK",16777215,1,"MGNT:L1B:1:LGPSCTRL.FLNK")
#! Link("MGNT:L1B:1:LGPSCTRL.FLNK","MGNT:L1B:1:LGPSSWITCH")
#! Field("MGNT:L1B:1:LGPSCTRL.FFVL",16777215,1,"MGNT:L1B:1:LGPSCTRL.FFVL")
#! Record("MGNT:L1B:1:LGPSSWITCH",460,322,0,0,"MGNT:L1B:1:LGPSSWITCH")
#! Field("MGNT:L1B:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:L1B:1:LGPSSWITCH.DOL1")
#! Link("MGNT:L1B:1:LGPSSWITCH.DOL1","MGNT:L1B:1:LGPSCTRL.FFVL")
#! Field("MGNT:L1B:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:L1B:1:LGPSSWITCH.LNK1")
#! Field("MGNT:L1B:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:L1B:1:LGPSSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLLGPSSGO",240,96,0,0,"MGNT:L1B:1:ALLLGPSSGO")
#! Field("MGNT:L1B:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:L1B:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:L1B:1:ALLLGPSSGO.LNK1","MGNT:L1B:1:ALLLGPSS.VAL")
#! Record("MGNT:L1B:1:ALLLGPSS",540,102,0,0,"MGNT:L1B:1:ALLLGPSS")
#! Field("MGNT:L1B:1:ALLLGPSS.VAL",16777215,0,"MGNT:L1B:1:ALLLGPSS.VAL")
#! Field("MGNT:L1B:1:ALLLGPSS.FLNK",16777215,1,"MGNT:L1B:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:L1B:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:L1B:1:QUADSWITCH")
}

record(seq, "MGNT:L1B:1:QUADSWITCH") {
  field(DOL1, "MGNT:L1B:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:QUADCTRL")
}

record(seq, "MGNT:L1B:1:ALLQUADSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:QUADCTRL",20,10,0,0,"MGNT:L1B:1:QUADCTRL")
#! Field("MGNT:L1B:1:QUADCTRL.FLNK",16777215,1,"MGNT:L1B:1:QUADCTRL.FLNK")
#! Link("MGNT:L1B:1:QUADCTRL.FLNK","MGNT:L1B:1:QUADSWITCH")
#! Field("MGNT:L1B:1:QUADCTRL.FFVL",16777215,1,"MGNT:L1B:1:QUADCTRL.FFVL")
#! Record("MGNT:L1B:1:QUADSWITCH",460,322,0,0,"MGNT:L1B:1:QUADSWITCH")
#! Field("MGNT:L1B:1:QUADSWITCH.DOL1",16777215,0,"MGNT:L1B:1:QUADSWITCH.DOL1")
#! Link("MGNT:L1B:1:QUADSWITCH.DOL1","MGNT:L1B:1:QUADCTRL.FFVL")
#! Field("MGNT:L1B:1:QUADSWITCH.LNK1",16777215,1,"MGNT:L1B:1:QUADSWITCH.LNK1")
#! Field("MGNT:L1B:1:QUADSWITCH.FLNK",16777215,1,"MGNT:L1B:1:QUADSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLQUADSGO",240,96,0,0,"MGNT:L1B:1:ALLQUADSGO")
#! Field("MGNT:L1B:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLQUADSGO.DOL1")
#! Field("MGNT:L1B:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLQUADSGO.LNK1")
#! Link("MGNT:L1B:1:ALLQUADSGO.LNK1","MGNT:L1B:1:ALLQUADS.VAL")
#! Record("MGNT:L1B:1:ALLQUADS",540,102,0,0,"MGNT:L1B:1:ALLQUADS")
#! Field("MGNT:L1B:1:ALLQUADS.VAL",16777215,0,"MGNT:L1B:1:ALLQUADS.VAL")
#! Field("MGNT:L1B:1:ALLQUADS.FLNK",16777215,1,"MGNT:L1B:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:L1B:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:L1B:1:XCORSWITCH")
}

record(seq, "MGNT:L1B:1:XCORSWITCH") {
  field(DOL1, "MGNT:L1B:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:XCORCTRL")
}

record(seq, "MGNT:L1B:1:ALLXCORSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:XCORCTRL",20,10,0,0,"MGNT:L1B:1:XCORCTRL")
#! Field("MGNT:L1B:1:XCORCTRL.FLNK",16777215,1,"MGNT:L1B:1:XCORCTRL.FLNK")
#! Link("MGNT:L1B:1:XCORCTRL.FLNK","MGNT:L1B:1:XCORSWITCH")
#! Field("MGNT:L1B:1:XCORCTRL.FFVL",16777215,1,"MGNT:L1B:1:XCORCTRL.FFVL")
#! Record("MGNT:L1B:1:XCORSWITCH",460,322,0,0,"MGNT:L1B:1:XCORSWITCH")
#! Field("MGNT:L1B:1:XCORSWITCH.DOL1",16777215,0,"MGNT:L1B:1:XCORSWITCH.DOL1")
#! Link("MGNT:L1B:1:XCORSWITCH.DOL1","MGNT:L1B:1:XCORCTRL.FFVL")
#! Field("MGNT:L1B:1:XCORSWITCH.LNK1",16777215,1,"MGNT:L1B:1:XCORSWITCH.LNK1")
#! Field("MGNT:L1B:1:XCORSWITCH.FLNK",16777215,1,"MGNT:L1B:1:XCORSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLXCORSGO",240,96,0,0,"MGNT:L1B:1:ALLXCORSGO")
#! Field("MGNT:L1B:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLXCORSGO.DOL1")
#! Field("MGNT:L1B:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLXCORSGO.LNK1")
#! Link("MGNT:L1B:1:ALLXCORSGO.LNK1","MGNT:L1B:1:ALLXCORS.VAL")
#! Record("MGNT:L1B:1:ALLXCORS",540,102,0,0,"MGNT:L1B:1:ALLXCORS")
#! Field("MGNT:L1B:1:ALLXCORS.VAL",16777215,0,"MGNT:L1B:1:ALLXCORS.VAL")
#! Field("MGNT:L1B:1:ALLXCORS.FLNK",16777215,1,"MGNT:L1B:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:L1B:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:L1B:1:YCORSWITCH")
}

record(seq, "MGNT:L1B:1:YCORSWITCH") {
  field(DOL1, "MGNT:L1B:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:YCORCTRL")
}

record(seq, "MGNT:L1B:1:ALLYCORSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:YCORCTRL",20,10,0,0,"MGNT:L1B:1:YCORCTRL")
#! Field("MGNT:L1B:1:YCORCTRL.FLNK",16777215,1,"MGNT:L1B:1:YCORCTRL.FLNK")
#! Link("MGNT:L1B:1:YCORCTRL.FLNK","MGNT:L1B:1:YCORSWITCH")
#! Field("MGNT:L1B:1:YCORCTRL.FFVL",16777215,1,"MGNT:L1B:1:YCORCTRL.FFVL")
#! Record("MGNT:L1B:1:YCORSWITCH",460,322,0,0,"MGNT:L1B:1:YCORSWITCH")
#! Field("MGNT:L1B:1:YCORSWITCH.DOL1",16777215,0,"MGNT:L1B:1:YCORSWITCH.DOL1")
#! Link("MGNT:L1B:1:YCORSWITCH.DOL1","MGNT:L1B:1:YCORCTRL.FFVL")
#! Field("MGNT:L1B:1:YCORSWITCH.LNK1",16777215,1,"MGNT:L1B:1:YCORSWITCH.LNK1")
#! Field("MGNT:L1B:1:YCORSWITCH.FLNK",16777215,1,"MGNT:L1B:1:YCORSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLYCORSGO",240,96,0,0,"MGNT:L1B:1:ALLYCORSGO")
#! Field("MGNT:L1B:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLYCORSGO.DOL1")
#! Field("MGNT:L1B:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLYCORSGO.LNK1")
#! Link("MGNT:L1B:1:ALLYCORSGO.LNK1","MGNT:L1B:1:ALLYCORS.VAL")
#! Record("MGNT:L1B:1:ALLYCORS",540,102,0,0,"MGNT:L1B:1:ALLYCORS")
#! Field("MGNT:L1B:1:ALLYCORS.VAL",16777215,0,"MGNT:L1B:1:ALLYCORS.VAL")
#! Field("MGNT:L1B:1:ALLYCORS.FLNK",16777215,1,"MGNT:L1B:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:L1B:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:L1B:1:SOLNSWITCH")
}

record(seq, "MGNT:L1B:1:SOLNSWITCH") {
  field(DOL1, "MGNT:L1B:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:SOLNCTRL")
}

record(seq, "MGNT:L1B:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:SOLNCTRL",20,10,0,0,"MGNT:L1B:1:SOLNCTRL")
#! Field("MGNT:L1B:1:SOLNCTRL.FLNK",16777215,1,"MGNT:L1B:1:SOLNCTRL.FLNK")
#! Link("MGNT:L1B:1:SOLNCTRL.FLNK","MGNT:L1B:1:SOLNSWITCH")
#! Field("MGNT:L1B:1:SOLNCTRL.FFVL",16777215,1,"MGNT:L1B:1:SOLNCTRL.FFVL")
#! Record("MGNT:L1B:1:SOLNSWITCH",460,322,0,0,"MGNT:L1B:1:SOLNSWITCH")
#! Field("MGNT:L1B:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:L1B:1:SOLNSWITCH.DOL1")
#! Link("MGNT:L1B:1:SOLNSWITCH.DOL1","MGNT:L1B:1:SOLNCTRL.FFVL")
#! Field("MGNT:L1B:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:L1B:1:SOLNSWITCH.LNK1")
#! Field("MGNT:L1B:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:L1B:1:SOLNSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLSOLNSGO",240,96,0,0,"MGNT:L1B:1:ALLSOLNSGO")
#! Field("MGNT:L1B:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:L1B:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:L1B:1:ALLSOLNSGO.LNK1","MGNT:L1B:1:ALLSOLNS.VAL")
#! Record("MGNT:L1B:1:ALLSOLNS",540,102,0,0,"MGNT:L1B:1:ALLSOLNS")
#! Field("MGNT:L1B:1:ALLSOLNS.VAL",16777215,0,"MGNT:L1B:1:ALLSOLNS.VAL")
#! Field("MGNT:L1B:1:ALLSOLNS.FLNK",16777215,1,"MGNT:L1B:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:L1B:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:L1B:1:KICKSWITCH")
}

record(seq, "MGNT:L1B:1:KICKSWITCH") {
  field(DOL1, "MGNT:L1B:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:KICKCTRL")
}

record(seq, "MGNT:L1B:1:ALLKICKSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:KICKCTRL",20,10,0,0,"MGNT:L1B:1:KICKCTRL")
#! Field("MGNT:L1B:1:KICKCTRL.FLNK",16777215,1,"MGNT:L1B:1:KICKCTRL.FLNK")
#! Link("MGNT:L1B:1:KICKCTRL.FLNK","MGNT:L1B:1:KICKSWITCH")
#! Field("MGNT:L1B:1:KICKCTRL.FFVL",16777215,1,"MGNT:L1B:1:KICKCTRL.FFVL")
#! Record("MGNT:L1B:1:KICKSWITCH",460,322,0,0,"MGNT:L1B:1:KICKSWITCH")
#! Field("MGNT:L1B:1:KICKSWITCH.DOL1",16777215,0,"MGNT:L1B:1:KICKSWITCH.DOL1")
#! Link("MGNT:L1B:1:KICKSWITCH.DOL1","MGNT:L1B:1:KICKCTRL.FFVL")
#! Field("MGNT:L1B:1:KICKSWITCH.LNK1",16777215,1,"MGNT:L1B:1:KICKSWITCH.LNK1")
#! Field("MGNT:L1B:1:KICKSWITCH.FLNK",16777215,1,"MGNT:L1B:1:KICKSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLKICKSGO",240,96,0,0,"MGNT:L1B:1:ALLKICKSGO")
#! Field("MGNT:L1B:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLKICKSGO.DOL1")
#! Field("MGNT:L1B:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLKICKSGO.LNK1")
#! Link("MGNT:L1B:1:ALLKICKSGO.LNK1","MGNT:L1B:1:ALLKICKS.VAL")
#! Record("MGNT:L1B:1:ALLKICKS",540,102,0,0,"MGNT:L1B:1:ALLKICKS")
#! Field("MGNT:L1B:1:ALLKICKS.VAL",16777215,0,"MGNT:L1B:1:ALLKICKS.VAL")
#! Field("MGNT:L1B:1:ALLKICKS.FLNK",16777215,1,"MGNT:L1B:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:L1B:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:L1B:1:SEXTSWITCH")
}

record(seq, "MGNT:L1B:1:SEXTSWITCH") {
  field(DOL1, "MGNT:L1B:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:L1B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L1B:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L1B:1:SEXTCTRL")
}

record(seq, "MGNT:L1B:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:L1B:1:ALLSTAR")
  field(LNK1, "MGNT:L1B:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:L1B:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L1B:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L1B:1:SEXTCTRL",20,10,0,0,"MGNT:L1B:1:SEXTCTRL")
#! Field("MGNT:L1B:1:SEXTCTRL.FLNK",16777215,1,"MGNT:L1B:1:SEXTCTRL.FLNK")
#! Link("MGNT:L1B:1:SEXTCTRL.FLNK","MGNT:L1B:1:SEXTSWITCH")
#! Field("MGNT:L1B:1:SEXTCTRL.FFVL",16777215,1,"MGNT:L1B:1:SEXTCTRL.FFVL")
#! Record("MGNT:L1B:1:SEXTSWITCH",460,322,0,0,"MGNT:L1B:1:SEXTSWITCH")
#! Field("MGNT:L1B:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:L1B:1:SEXTSWITCH.DOL1")
#! Link("MGNT:L1B:1:SEXTSWITCH.DOL1","MGNT:L1B:1:SEXTCTRL.FFVL")
#! Field("MGNT:L1B:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:L1B:1:SEXTSWITCH.LNK1")
#! Field("MGNT:L1B:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:L1B:1:SEXTSWITCH.FLNK")
#! Record("MGNT:L1B:1:ALLSEXTSGO",240,96,0,0,"MGNT:L1B:1:ALLSEXTSGO")
#! Field("MGNT:L1B:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:L1B:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:L1B:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:L1B:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:L1B:1:ALLSEXTSGO.LNK1","MGNT:L1B:1:ALLSEXTS.VAL")
#! Record("MGNT:L1B:1:ALLSEXTS",540,102,0,0,"MGNT:L1B:1:ALLSEXTS")
#! Field("MGNT:L1B:1:ALLSEXTS.VAL",16777215,0,"MGNT:L1B:1:ALLSEXTS.VAL")
#! Field("MGNT:L1B:1:ALLSEXTS.FLNK",16777215,1,"MGNT:L1B:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:BC2B:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:BC2B:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:BC2B:1:CTRL CA PP")
  field(LNK2, "MGNT:BC2B:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:BC2B:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:BC2B:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:BC2B:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:BC2B:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:BC2B:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:BC2B:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:BC2B:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:BC2B:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:BC2B:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:BC2B:1:ALLSWITCH")
}

record(seq, "MGNT:BC2B:1:ALLSWITCH") {
  field(DOL1, "MGNT:BC2B:1:CTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:CTRL")
}

record(bo, "MGNT:BC2B:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLSTARGO")
}

record(fanout, "MGNT:BC2B:1:ALLSTARGO") {
  field(LNK1, "MGNT:BC2B:1:ALLBENDSGO")
  field(LNK2, "MGNT:BC2B:1:ALLBTRMSGO")
  field(LNK3, "MGNT:BC2B:1:ALLLGPSSGO")
  field(LNK4, "MGNT:BC2B:1:ALLQUADSGO")
  field(LNK5, "MGNT:BC2B:1:ALLXCORSGO")
  field(LNK6, "MGNT:BC2B:1:ALLYCORSGO")
  field(FLNK, "MGNT:BC2B:1:ALLSTARGO_2")
}
record(fanout, "MGNT:BC2B:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:BC2B:1:ALLSOLNSGO")
  field(LNK2, "MGNT:BC2B:1:ALLKICKSGO")
  field(LNK3, "MGNT:BC2B:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:BC2B:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:BC2B:1:BENDSWITCH")
}

record(seq, "MGNT:BC2B:1:BENDSWITCH") {
  field(DOL1, "MGNT:BC2B:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:BENDCTRL")
}

record(seq, "MGNT:BC2B:1:ALLBENDSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:BENDCTRL",20,10,0,0,"MGNT:BC2B:1:BENDCTRL")
#! Field("MGNT:BC2B:1:BENDCTRL.FLNK",16777215,1,"MGNT:BC2B:1:BENDCTRL.FLNK")
#! Link("MGNT:BC2B:1:BENDCTRL.FLNK","MGNT:BC2B:1:BENDSWITCH")
#! Field("MGNT:BC2B:1:BENDCTRL.FFVL",16777215,1,"MGNT:BC2B:1:BENDCTRL.FFVL")
#! Record("MGNT:BC2B:1:BENDSWITCH",460,322,0,0,"MGNT:BC2B:1:BENDSWITCH")
#! Field("MGNT:BC2B:1:BENDSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:BENDSWITCH.DOL1")
#! Link("MGNT:BC2B:1:BENDSWITCH.DOL1","MGNT:BC2B:1:BENDCTRL.FFVL")
#! Field("MGNT:BC2B:1:BENDSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:BENDSWITCH.LNK1")
#! Field("MGNT:BC2B:1:BENDSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:BENDSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLBENDSGO",240,96,0,0,"MGNT:BC2B:1:ALLBENDSGO")
#! Field("MGNT:BC2B:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLBENDSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLBENDSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLBENDSGO.LNK1","MGNT:BC2B:1:ALLBENDS.VAL")
#! Record("MGNT:BC2B:1:ALLBENDS",540,102,0,0,"MGNT:BC2B:1:ALLBENDS")
#! Field("MGNT:BC2B:1:ALLBENDS.VAL",16777215,0,"MGNT:BC2B:1:ALLBENDS.VAL")
#! Field("MGNT:BC2B:1:ALLBENDS.FLNK",16777215,1,"MGNT:BC2B:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:BC2B:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BC2B:1:BTRMSWITCH")
}

record(seq, "MGNT:BC2B:1:BTRMSWITCH") {
  field(DOL1, "MGNT:BC2B:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:BTRMCTRL")
}

record(seq, "MGNT:BC2B:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:BTRMCTRL",20,10,0,0,"MGNT:BC2B:1:BTRMCTRL")
#! Field("MGNT:BC2B:1:BTRMCTRL.FLNK",16777215,1,"MGNT:BC2B:1:BTRMCTRL.FLNK")
#! Link("MGNT:BC2B:1:BTRMCTRL.FLNK","MGNT:BC2B:1:BTRMSWITCH")
#! Field("MGNT:BC2B:1:BTRMCTRL.FFVL",16777215,1,"MGNT:BC2B:1:BTRMCTRL.FFVL")
#! Record("MGNT:BC2B:1:BTRMSWITCH",460,322,0,0,"MGNT:BC2B:1:BTRMSWITCH")
#! Field("MGNT:BC2B:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:BTRMSWITCH.DOL1")
#! Link("MGNT:BC2B:1:BTRMSWITCH.DOL1","MGNT:BC2B:1:BTRMCTRL.FFVL")
#! Field("MGNT:BC2B:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:BTRMSWITCH.LNK1")
#! Field("MGNT:BC2B:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:BTRMSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLBTRMSGO",240,96,0,0,"MGNT:BC2B:1:ALLBTRMSGO")
#! Field("MGNT:BC2B:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLBTRMSGO.LNK1","MGNT:BC2B:1:ALLBTRMS.VAL")
#! Record("MGNT:BC2B:1:ALLBTRMS",540,102,0,0,"MGNT:BC2B:1:ALLBTRMS")
#! Field("MGNT:BC2B:1:ALLBTRMS.VAL",16777215,0,"MGNT:BC2B:1:ALLBTRMS.VAL")
#! Field("MGNT:BC2B:1:ALLBTRMS.FLNK",16777215,1,"MGNT:BC2B:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:BC2B:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BC2B:1:LGPSSWITCH")
}

record(seq, "MGNT:BC2B:1:LGPSSWITCH") {
  field(DOL1, "MGNT:BC2B:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:LGPSCTRL")
}

record(seq, "MGNT:BC2B:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:LGPSCTRL",20,10,0,0,"MGNT:BC2B:1:LGPSCTRL")
#! Field("MGNT:BC2B:1:LGPSCTRL.FLNK",16777215,1,"MGNT:BC2B:1:LGPSCTRL.FLNK")
#! Link("MGNT:BC2B:1:LGPSCTRL.FLNK","MGNT:BC2B:1:LGPSSWITCH")
#! Field("MGNT:BC2B:1:LGPSCTRL.FFVL",16777215,1,"MGNT:BC2B:1:LGPSCTRL.FFVL")
#! Record("MGNT:BC2B:1:LGPSSWITCH",460,322,0,0,"MGNT:BC2B:1:LGPSSWITCH")
#! Field("MGNT:BC2B:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:LGPSSWITCH.DOL1")
#! Link("MGNT:BC2B:1:LGPSSWITCH.DOL1","MGNT:BC2B:1:LGPSCTRL.FFVL")
#! Field("MGNT:BC2B:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:LGPSSWITCH.LNK1")
#! Field("MGNT:BC2B:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:LGPSSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLLGPSSGO",240,96,0,0,"MGNT:BC2B:1:ALLLGPSSGO")
#! Field("MGNT:BC2B:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLLGPSSGO.LNK1","MGNT:BC2B:1:ALLLGPSS.VAL")
#! Record("MGNT:BC2B:1:ALLLGPSS",540,102,0,0,"MGNT:BC2B:1:ALLLGPSS")
#! Field("MGNT:BC2B:1:ALLLGPSS.VAL",16777215,0,"MGNT:BC2B:1:ALLLGPSS.VAL")
#! Field("MGNT:BC2B:1:ALLLGPSS.FLNK",16777215,1,"MGNT:BC2B:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:BC2B:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:BC2B:1:QUADSWITCH")
}

record(seq, "MGNT:BC2B:1:QUADSWITCH") {
  field(DOL1, "MGNT:BC2B:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:QUADCTRL")
}

record(seq, "MGNT:BC2B:1:ALLQUADSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:QUADCTRL",20,10,0,0,"MGNT:BC2B:1:QUADCTRL")
#! Field("MGNT:BC2B:1:QUADCTRL.FLNK",16777215,1,"MGNT:BC2B:1:QUADCTRL.FLNK")
#! Link("MGNT:BC2B:1:QUADCTRL.FLNK","MGNT:BC2B:1:QUADSWITCH")
#! Field("MGNT:BC2B:1:QUADCTRL.FFVL",16777215,1,"MGNT:BC2B:1:QUADCTRL.FFVL")
#! Record("MGNT:BC2B:1:QUADSWITCH",460,322,0,0,"MGNT:BC2B:1:QUADSWITCH")
#! Field("MGNT:BC2B:1:QUADSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:QUADSWITCH.DOL1")
#! Link("MGNT:BC2B:1:QUADSWITCH.DOL1","MGNT:BC2B:1:QUADCTRL.FFVL")
#! Field("MGNT:BC2B:1:QUADSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:QUADSWITCH.LNK1")
#! Field("MGNT:BC2B:1:QUADSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:QUADSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLQUADSGO",240,96,0,0,"MGNT:BC2B:1:ALLQUADSGO")
#! Field("MGNT:BC2B:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLQUADSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLQUADSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLQUADSGO.LNK1","MGNT:BC2B:1:ALLQUADS.VAL")
#! Record("MGNT:BC2B:1:ALLQUADS",540,102,0,0,"MGNT:BC2B:1:ALLQUADS")
#! Field("MGNT:BC2B:1:ALLQUADS.VAL",16777215,0,"MGNT:BC2B:1:ALLQUADS.VAL")
#! Field("MGNT:BC2B:1:ALLQUADS.FLNK",16777215,1,"MGNT:BC2B:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:BC2B:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:BC2B:1:XCORSWITCH")
}

record(seq, "MGNT:BC2B:1:XCORSWITCH") {
  field(DOL1, "MGNT:BC2B:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:XCORCTRL")
}

record(seq, "MGNT:BC2B:1:ALLXCORSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:XCORCTRL",20,10,0,0,"MGNT:BC2B:1:XCORCTRL")
#! Field("MGNT:BC2B:1:XCORCTRL.FLNK",16777215,1,"MGNT:BC2B:1:XCORCTRL.FLNK")
#! Link("MGNT:BC2B:1:XCORCTRL.FLNK","MGNT:BC2B:1:XCORSWITCH")
#! Field("MGNT:BC2B:1:XCORCTRL.FFVL",16777215,1,"MGNT:BC2B:1:XCORCTRL.FFVL")
#! Record("MGNT:BC2B:1:XCORSWITCH",460,322,0,0,"MGNT:BC2B:1:XCORSWITCH")
#! Field("MGNT:BC2B:1:XCORSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:XCORSWITCH.DOL1")
#! Link("MGNT:BC2B:1:XCORSWITCH.DOL1","MGNT:BC2B:1:XCORCTRL.FFVL")
#! Field("MGNT:BC2B:1:XCORSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:XCORSWITCH.LNK1")
#! Field("MGNT:BC2B:1:XCORSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:XCORSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLXCORSGO",240,96,0,0,"MGNT:BC2B:1:ALLXCORSGO")
#! Field("MGNT:BC2B:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLXCORSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLXCORSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLXCORSGO.LNK1","MGNT:BC2B:1:ALLXCORS.VAL")
#! Record("MGNT:BC2B:1:ALLXCORS",540,102,0,0,"MGNT:BC2B:1:ALLXCORS")
#! Field("MGNT:BC2B:1:ALLXCORS.VAL",16777215,0,"MGNT:BC2B:1:ALLXCORS.VAL")
#! Field("MGNT:BC2B:1:ALLXCORS.FLNK",16777215,1,"MGNT:BC2B:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:BC2B:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:BC2B:1:YCORSWITCH")
}

record(seq, "MGNT:BC2B:1:YCORSWITCH") {
  field(DOL1, "MGNT:BC2B:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:YCORCTRL")
}

record(seq, "MGNT:BC2B:1:ALLYCORSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:YCORCTRL",20,10,0,0,"MGNT:BC2B:1:YCORCTRL")
#! Field("MGNT:BC2B:1:YCORCTRL.FLNK",16777215,1,"MGNT:BC2B:1:YCORCTRL.FLNK")
#! Link("MGNT:BC2B:1:YCORCTRL.FLNK","MGNT:BC2B:1:YCORSWITCH")
#! Field("MGNT:BC2B:1:YCORCTRL.FFVL",16777215,1,"MGNT:BC2B:1:YCORCTRL.FFVL")
#! Record("MGNT:BC2B:1:YCORSWITCH",460,322,0,0,"MGNT:BC2B:1:YCORSWITCH")
#! Field("MGNT:BC2B:1:YCORSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:YCORSWITCH.DOL1")
#! Link("MGNT:BC2B:1:YCORSWITCH.DOL1","MGNT:BC2B:1:YCORCTRL.FFVL")
#! Field("MGNT:BC2B:1:YCORSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:YCORSWITCH.LNK1")
#! Field("MGNT:BC2B:1:YCORSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:YCORSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLYCORSGO",240,96,0,0,"MGNT:BC2B:1:ALLYCORSGO")
#! Field("MGNT:BC2B:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLYCORSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLYCORSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLYCORSGO.LNK1","MGNT:BC2B:1:ALLYCORS.VAL")
#! Record("MGNT:BC2B:1:ALLYCORS",540,102,0,0,"MGNT:BC2B:1:ALLYCORS")
#! Field("MGNT:BC2B:1:ALLYCORS.VAL",16777215,0,"MGNT:BC2B:1:ALLYCORS.VAL")
#! Field("MGNT:BC2B:1:ALLYCORS.FLNK",16777215,1,"MGNT:BC2B:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:BC2B:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:BC2B:1:SOLNSWITCH")
}

record(seq, "MGNT:BC2B:1:SOLNSWITCH") {
  field(DOL1, "MGNT:BC2B:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:SOLNCTRL")
}

record(seq, "MGNT:BC2B:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:SOLNCTRL",20,10,0,0,"MGNT:BC2B:1:SOLNCTRL")
#! Field("MGNT:BC2B:1:SOLNCTRL.FLNK",16777215,1,"MGNT:BC2B:1:SOLNCTRL.FLNK")
#! Link("MGNT:BC2B:1:SOLNCTRL.FLNK","MGNT:BC2B:1:SOLNSWITCH")
#! Field("MGNT:BC2B:1:SOLNCTRL.FFVL",16777215,1,"MGNT:BC2B:1:SOLNCTRL.FFVL")
#! Record("MGNT:BC2B:1:SOLNSWITCH",460,322,0,0,"MGNT:BC2B:1:SOLNSWITCH")
#! Field("MGNT:BC2B:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:SOLNSWITCH.DOL1")
#! Link("MGNT:BC2B:1:SOLNSWITCH.DOL1","MGNT:BC2B:1:SOLNCTRL.FFVL")
#! Field("MGNT:BC2B:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:SOLNSWITCH.LNK1")
#! Field("MGNT:BC2B:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:SOLNSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLSOLNSGO",240,96,0,0,"MGNT:BC2B:1:ALLSOLNSGO")
#! Field("MGNT:BC2B:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLSOLNSGO.LNK1","MGNT:BC2B:1:ALLSOLNS.VAL")
#! Record("MGNT:BC2B:1:ALLSOLNS",540,102,0,0,"MGNT:BC2B:1:ALLSOLNS")
#! Field("MGNT:BC2B:1:ALLSOLNS.VAL",16777215,0,"MGNT:BC2B:1:ALLSOLNS.VAL")
#! Field("MGNT:BC2B:1:ALLSOLNS.FLNK",16777215,1,"MGNT:BC2B:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:BC2B:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:BC2B:1:KICKSWITCH")
}

record(seq, "MGNT:BC2B:1:KICKSWITCH") {
  field(DOL1, "MGNT:BC2B:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:KICKCTRL")
}

record(seq, "MGNT:BC2B:1:ALLKICKSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:KICKCTRL",20,10,0,0,"MGNT:BC2B:1:KICKCTRL")
#! Field("MGNT:BC2B:1:KICKCTRL.FLNK",16777215,1,"MGNT:BC2B:1:KICKCTRL.FLNK")
#! Link("MGNT:BC2B:1:KICKCTRL.FLNK","MGNT:BC2B:1:KICKSWITCH")
#! Field("MGNT:BC2B:1:KICKCTRL.FFVL",16777215,1,"MGNT:BC2B:1:KICKCTRL.FFVL")
#! Record("MGNT:BC2B:1:KICKSWITCH",460,322,0,0,"MGNT:BC2B:1:KICKSWITCH")
#! Field("MGNT:BC2B:1:KICKSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:KICKSWITCH.DOL1")
#! Link("MGNT:BC2B:1:KICKSWITCH.DOL1","MGNT:BC2B:1:KICKCTRL.FFVL")
#! Field("MGNT:BC2B:1:KICKSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:KICKSWITCH.LNK1")
#! Field("MGNT:BC2B:1:KICKSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:KICKSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLKICKSGO",240,96,0,0,"MGNT:BC2B:1:ALLKICKSGO")
#! Field("MGNT:BC2B:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLKICKSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLKICKSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLKICKSGO.LNK1","MGNT:BC2B:1:ALLKICKS.VAL")
#! Record("MGNT:BC2B:1:ALLKICKS",540,102,0,0,"MGNT:BC2B:1:ALLKICKS")
#! Field("MGNT:BC2B:1:ALLKICKS.VAL",16777215,0,"MGNT:BC2B:1:ALLKICKS.VAL")
#! Field("MGNT:BC2B:1:ALLKICKS.FLNK",16777215,1,"MGNT:BC2B:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:BC2B:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:BC2B:1:SEXTSWITCH")
}

record(seq, "MGNT:BC2B:1:SEXTSWITCH") {
  field(DOL1, "MGNT:BC2B:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:BC2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BC2B:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BC2B:1:SEXTCTRL")
}

record(seq, "MGNT:BC2B:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:BC2B:1:ALLSTAR")
  field(LNK1, "MGNT:BC2B:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:BC2B:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BC2B:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BC2B:1:SEXTCTRL",20,10,0,0,"MGNT:BC2B:1:SEXTCTRL")
#! Field("MGNT:BC2B:1:SEXTCTRL.FLNK",16777215,1,"MGNT:BC2B:1:SEXTCTRL.FLNK")
#! Link("MGNT:BC2B:1:SEXTCTRL.FLNK","MGNT:BC2B:1:SEXTSWITCH")
#! Field("MGNT:BC2B:1:SEXTCTRL.FFVL",16777215,1,"MGNT:BC2B:1:SEXTCTRL.FFVL")
#! Record("MGNT:BC2B:1:SEXTSWITCH",460,322,0,0,"MGNT:BC2B:1:SEXTSWITCH")
#! Field("MGNT:BC2B:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:BC2B:1:SEXTSWITCH.DOL1")
#! Link("MGNT:BC2B:1:SEXTSWITCH.DOL1","MGNT:BC2B:1:SEXTCTRL.FFVL")
#! Field("MGNT:BC2B:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:BC2B:1:SEXTSWITCH.LNK1")
#! Field("MGNT:BC2B:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:BC2B:1:SEXTSWITCH.FLNK")
#! Record("MGNT:BC2B:1:ALLSEXTSGO",240,96,0,0,"MGNT:BC2B:1:ALLSEXTSGO")
#! Field("MGNT:BC2B:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:BC2B:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:BC2B:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:BC2B:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:BC2B:1:ALLSEXTSGO.LNK1","MGNT:BC2B:1:ALLSEXTS.VAL")
#! Record("MGNT:BC2B:1:ALLSEXTS",540,102,0,0,"MGNT:BC2B:1:ALLSEXTS")
#! Field("MGNT:BC2B:1:ALLSEXTS.VAL",16777215,0,"MGNT:BC2B:1:ALLSEXTS.VAL")
#! Field("MGNT:BC2B:1:ALLSEXTS.FLNK",16777215,1,"MGNT:BC2B:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:L2B:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:L2B:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:L2B:1:CTRL CA PP")
  field(LNK2, "MGNT:L2B:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:L2B:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:L2B:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:L2B:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:L2B:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:L2B:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:L2B:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:L2B:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:L2B:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:L2B:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:L2B:1:ALLSWITCH")
}

record(seq, "MGNT:L2B:1:ALLSWITCH") {
  field(DOL1, "MGNT:L2B:1:CTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:CTRL")
}

record(bo, "MGNT:L2B:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:L2B:1:ALLSTARGO")
}

record(fanout, "MGNT:L2B:1:ALLSTARGO") {
  field(LNK1, "MGNT:L2B:1:ALLBENDSGO")
  field(LNK2, "MGNT:L2B:1:ALLBTRMSGO")
  field(LNK3, "MGNT:L2B:1:ALLLGPSSGO")
  field(LNK4, "MGNT:L2B:1:ALLQUADSGO")
  field(LNK5, "MGNT:L2B:1:ALLXCORSGO")
  field(LNK6, "MGNT:L2B:1:ALLYCORSGO")
  field(FLNK, "MGNT:L2B:1:ALLSTARGO_2")
}
record(fanout, "MGNT:L2B:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:L2B:1:ALLSOLNSGO")
  field(LNK2, "MGNT:L2B:1:ALLKICKSGO")
  field(LNK3, "MGNT:L2B:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:L2B:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:L2B:1:BENDSWITCH")
}

record(seq, "MGNT:L2B:1:BENDSWITCH") {
  field(DOL1, "MGNT:L2B:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:BENDCTRL")
}

record(seq, "MGNT:L2B:1:ALLBENDSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:BENDCTRL",20,10,0,0,"MGNT:L2B:1:BENDCTRL")
#! Field("MGNT:L2B:1:BENDCTRL.FLNK",16777215,1,"MGNT:L2B:1:BENDCTRL.FLNK")
#! Link("MGNT:L2B:1:BENDCTRL.FLNK","MGNT:L2B:1:BENDSWITCH")
#! Field("MGNT:L2B:1:BENDCTRL.FFVL",16777215,1,"MGNT:L2B:1:BENDCTRL.FFVL")
#! Record("MGNT:L2B:1:BENDSWITCH",460,322,0,0,"MGNT:L2B:1:BENDSWITCH")
#! Field("MGNT:L2B:1:BENDSWITCH.DOL1",16777215,0,"MGNT:L2B:1:BENDSWITCH.DOL1")
#! Link("MGNT:L2B:1:BENDSWITCH.DOL1","MGNT:L2B:1:BENDCTRL.FFVL")
#! Field("MGNT:L2B:1:BENDSWITCH.LNK1",16777215,1,"MGNT:L2B:1:BENDSWITCH.LNK1")
#! Field("MGNT:L2B:1:BENDSWITCH.FLNK",16777215,1,"MGNT:L2B:1:BENDSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLBENDSGO",240,96,0,0,"MGNT:L2B:1:ALLBENDSGO")
#! Field("MGNT:L2B:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLBENDSGO.DOL1")
#! Field("MGNT:L2B:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLBENDSGO.LNK1")
#! Link("MGNT:L2B:1:ALLBENDSGO.LNK1","MGNT:L2B:1:ALLBENDS.VAL")
#! Record("MGNT:L2B:1:ALLBENDS",540,102,0,0,"MGNT:L2B:1:ALLBENDS")
#! Field("MGNT:L2B:1:ALLBENDS.VAL",16777215,0,"MGNT:L2B:1:ALLBENDS.VAL")
#! Field("MGNT:L2B:1:ALLBENDS.FLNK",16777215,1,"MGNT:L2B:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:L2B:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L2B:1:BTRMSWITCH")
}

record(seq, "MGNT:L2B:1:BTRMSWITCH") {
  field(DOL1, "MGNT:L2B:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:BTRMCTRL")
}

record(seq, "MGNT:L2B:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:BTRMCTRL",20,10,0,0,"MGNT:L2B:1:BTRMCTRL")
#! Field("MGNT:L2B:1:BTRMCTRL.FLNK",16777215,1,"MGNT:L2B:1:BTRMCTRL.FLNK")
#! Link("MGNT:L2B:1:BTRMCTRL.FLNK","MGNT:L2B:1:BTRMSWITCH")
#! Field("MGNT:L2B:1:BTRMCTRL.FFVL",16777215,1,"MGNT:L2B:1:BTRMCTRL.FFVL")
#! Record("MGNT:L2B:1:BTRMSWITCH",460,322,0,0,"MGNT:L2B:1:BTRMSWITCH")
#! Field("MGNT:L2B:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:L2B:1:BTRMSWITCH.DOL1")
#! Link("MGNT:L2B:1:BTRMSWITCH.DOL1","MGNT:L2B:1:BTRMCTRL.FFVL")
#! Field("MGNT:L2B:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:L2B:1:BTRMSWITCH.LNK1")
#! Field("MGNT:L2B:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:L2B:1:BTRMSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLBTRMSGO",240,96,0,0,"MGNT:L2B:1:ALLBTRMSGO")
#! Field("MGNT:L2B:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:L2B:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:L2B:1:ALLBTRMSGO.LNK1","MGNT:L2B:1:ALLBTRMS.VAL")
#! Record("MGNT:L2B:1:ALLBTRMS",540,102,0,0,"MGNT:L2B:1:ALLBTRMS")
#! Field("MGNT:L2B:1:ALLBTRMS.VAL",16777215,0,"MGNT:L2B:1:ALLBTRMS.VAL")
#! Field("MGNT:L2B:1:ALLBTRMS.FLNK",16777215,1,"MGNT:L2B:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:L2B:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L2B:1:LGPSSWITCH")
}

record(seq, "MGNT:L2B:1:LGPSSWITCH") {
  field(DOL1, "MGNT:L2B:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:LGPSCTRL")
}

record(seq, "MGNT:L2B:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:LGPSCTRL",20,10,0,0,"MGNT:L2B:1:LGPSCTRL")
#! Field("MGNT:L2B:1:LGPSCTRL.FLNK",16777215,1,"MGNT:L2B:1:LGPSCTRL.FLNK")
#! Link("MGNT:L2B:1:LGPSCTRL.FLNK","MGNT:L2B:1:LGPSSWITCH")
#! Field("MGNT:L2B:1:LGPSCTRL.FFVL",16777215,1,"MGNT:L2B:1:LGPSCTRL.FFVL")
#! Record("MGNT:L2B:1:LGPSSWITCH",460,322,0,0,"MGNT:L2B:1:LGPSSWITCH")
#! Field("MGNT:L2B:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:L2B:1:LGPSSWITCH.DOL1")
#! Link("MGNT:L2B:1:LGPSSWITCH.DOL1","MGNT:L2B:1:LGPSCTRL.FFVL")
#! Field("MGNT:L2B:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:L2B:1:LGPSSWITCH.LNK1")
#! Field("MGNT:L2B:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:L2B:1:LGPSSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLLGPSSGO",240,96,0,0,"MGNT:L2B:1:ALLLGPSSGO")
#! Field("MGNT:L2B:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:L2B:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:L2B:1:ALLLGPSSGO.LNK1","MGNT:L2B:1:ALLLGPSS.VAL")
#! Record("MGNT:L2B:1:ALLLGPSS",540,102,0,0,"MGNT:L2B:1:ALLLGPSS")
#! Field("MGNT:L2B:1:ALLLGPSS.VAL",16777215,0,"MGNT:L2B:1:ALLLGPSS.VAL")
#! Field("MGNT:L2B:1:ALLLGPSS.FLNK",16777215,1,"MGNT:L2B:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:L2B:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:L2B:1:QUADSWITCH")
}

record(seq, "MGNT:L2B:1:QUADSWITCH") {
  field(DOL1, "MGNT:L2B:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:QUADCTRL")
}

record(seq, "MGNT:L2B:1:ALLQUADSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:QUADCTRL",20,10,0,0,"MGNT:L2B:1:QUADCTRL")
#! Field("MGNT:L2B:1:QUADCTRL.FLNK",16777215,1,"MGNT:L2B:1:QUADCTRL.FLNK")
#! Link("MGNT:L2B:1:QUADCTRL.FLNK","MGNT:L2B:1:QUADSWITCH")
#! Field("MGNT:L2B:1:QUADCTRL.FFVL",16777215,1,"MGNT:L2B:1:QUADCTRL.FFVL")
#! Record("MGNT:L2B:1:QUADSWITCH",460,322,0,0,"MGNT:L2B:1:QUADSWITCH")
#! Field("MGNT:L2B:1:QUADSWITCH.DOL1",16777215,0,"MGNT:L2B:1:QUADSWITCH.DOL1")
#! Link("MGNT:L2B:1:QUADSWITCH.DOL1","MGNT:L2B:1:QUADCTRL.FFVL")
#! Field("MGNT:L2B:1:QUADSWITCH.LNK1",16777215,1,"MGNT:L2B:1:QUADSWITCH.LNK1")
#! Field("MGNT:L2B:1:QUADSWITCH.FLNK",16777215,1,"MGNT:L2B:1:QUADSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLQUADSGO",240,96,0,0,"MGNT:L2B:1:ALLQUADSGO")
#! Field("MGNT:L2B:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLQUADSGO.DOL1")
#! Field("MGNT:L2B:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLQUADSGO.LNK1")
#! Link("MGNT:L2B:1:ALLQUADSGO.LNK1","MGNT:L2B:1:ALLQUADS.VAL")
#! Record("MGNT:L2B:1:ALLQUADS",540,102,0,0,"MGNT:L2B:1:ALLQUADS")
#! Field("MGNT:L2B:1:ALLQUADS.VAL",16777215,0,"MGNT:L2B:1:ALLQUADS.VAL")
#! Field("MGNT:L2B:1:ALLQUADS.FLNK",16777215,1,"MGNT:L2B:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:L2B:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:L2B:1:XCORSWITCH")
}

record(seq, "MGNT:L2B:1:XCORSWITCH") {
  field(DOL1, "MGNT:L2B:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:XCORCTRL")
}

record(seq, "MGNT:L2B:1:ALLXCORSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:XCORCTRL",20,10,0,0,"MGNT:L2B:1:XCORCTRL")
#! Field("MGNT:L2B:1:XCORCTRL.FLNK",16777215,1,"MGNT:L2B:1:XCORCTRL.FLNK")
#! Link("MGNT:L2B:1:XCORCTRL.FLNK","MGNT:L2B:1:XCORSWITCH")
#! Field("MGNT:L2B:1:XCORCTRL.FFVL",16777215,1,"MGNT:L2B:1:XCORCTRL.FFVL")
#! Record("MGNT:L2B:1:XCORSWITCH",460,322,0,0,"MGNT:L2B:1:XCORSWITCH")
#! Field("MGNT:L2B:1:XCORSWITCH.DOL1",16777215,0,"MGNT:L2B:1:XCORSWITCH.DOL1")
#! Link("MGNT:L2B:1:XCORSWITCH.DOL1","MGNT:L2B:1:XCORCTRL.FFVL")
#! Field("MGNT:L2B:1:XCORSWITCH.LNK1",16777215,1,"MGNT:L2B:1:XCORSWITCH.LNK1")
#! Field("MGNT:L2B:1:XCORSWITCH.FLNK",16777215,1,"MGNT:L2B:1:XCORSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLXCORSGO",240,96,0,0,"MGNT:L2B:1:ALLXCORSGO")
#! Field("MGNT:L2B:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLXCORSGO.DOL1")
#! Field("MGNT:L2B:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLXCORSGO.LNK1")
#! Link("MGNT:L2B:1:ALLXCORSGO.LNK1","MGNT:L2B:1:ALLXCORS.VAL")
#! Record("MGNT:L2B:1:ALLXCORS",540,102,0,0,"MGNT:L2B:1:ALLXCORS")
#! Field("MGNT:L2B:1:ALLXCORS.VAL",16777215,0,"MGNT:L2B:1:ALLXCORS.VAL")
#! Field("MGNT:L2B:1:ALLXCORS.FLNK",16777215,1,"MGNT:L2B:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:L2B:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:L2B:1:YCORSWITCH")
}

record(seq, "MGNT:L2B:1:YCORSWITCH") {
  field(DOL1, "MGNT:L2B:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:YCORCTRL")
}

record(seq, "MGNT:L2B:1:ALLYCORSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:YCORCTRL",20,10,0,0,"MGNT:L2B:1:YCORCTRL")
#! Field("MGNT:L2B:1:YCORCTRL.FLNK",16777215,1,"MGNT:L2B:1:YCORCTRL.FLNK")
#! Link("MGNT:L2B:1:YCORCTRL.FLNK","MGNT:L2B:1:YCORSWITCH")
#! Field("MGNT:L2B:1:YCORCTRL.FFVL",16777215,1,"MGNT:L2B:1:YCORCTRL.FFVL")
#! Record("MGNT:L2B:1:YCORSWITCH",460,322,0,0,"MGNT:L2B:1:YCORSWITCH")
#! Field("MGNT:L2B:1:YCORSWITCH.DOL1",16777215,0,"MGNT:L2B:1:YCORSWITCH.DOL1")
#! Link("MGNT:L2B:1:YCORSWITCH.DOL1","MGNT:L2B:1:YCORCTRL.FFVL")
#! Field("MGNT:L2B:1:YCORSWITCH.LNK1",16777215,1,"MGNT:L2B:1:YCORSWITCH.LNK1")
#! Field("MGNT:L2B:1:YCORSWITCH.FLNK",16777215,1,"MGNT:L2B:1:YCORSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLYCORSGO",240,96,0,0,"MGNT:L2B:1:ALLYCORSGO")
#! Field("MGNT:L2B:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLYCORSGO.DOL1")
#! Field("MGNT:L2B:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLYCORSGO.LNK1")
#! Link("MGNT:L2B:1:ALLYCORSGO.LNK1","MGNT:L2B:1:ALLYCORS.VAL")
#! Record("MGNT:L2B:1:ALLYCORS",540,102,0,0,"MGNT:L2B:1:ALLYCORS")
#! Field("MGNT:L2B:1:ALLYCORS.VAL",16777215,0,"MGNT:L2B:1:ALLYCORS.VAL")
#! Field("MGNT:L2B:1:ALLYCORS.FLNK",16777215,1,"MGNT:L2B:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:L2B:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:L2B:1:SOLNSWITCH")
}

record(seq, "MGNT:L2B:1:SOLNSWITCH") {
  field(DOL1, "MGNT:L2B:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:SOLNCTRL")
}

record(seq, "MGNT:L2B:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:SOLNCTRL",20,10,0,0,"MGNT:L2B:1:SOLNCTRL")
#! Field("MGNT:L2B:1:SOLNCTRL.FLNK",16777215,1,"MGNT:L2B:1:SOLNCTRL.FLNK")
#! Link("MGNT:L2B:1:SOLNCTRL.FLNK","MGNT:L2B:1:SOLNSWITCH")
#! Field("MGNT:L2B:1:SOLNCTRL.FFVL",16777215,1,"MGNT:L2B:1:SOLNCTRL.FFVL")
#! Record("MGNT:L2B:1:SOLNSWITCH",460,322,0,0,"MGNT:L2B:1:SOLNSWITCH")
#! Field("MGNT:L2B:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:L2B:1:SOLNSWITCH.DOL1")
#! Link("MGNT:L2B:1:SOLNSWITCH.DOL1","MGNT:L2B:1:SOLNCTRL.FFVL")
#! Field("MGNT:L2B:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:L2B:1:SOLNSWITCH.LNK1")
#! Field("MGNT:L2B:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:L2B:1:SOLNSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLSOLNSGO",240,96,0,0,"MGNT:L2B:1:ALLSOLNSGO")
#! Field("MGNT:L2B:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:L2B:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:L2B:1:ALLSOLNSGO.LNK1","MGNT:L2B:1:ALLSOLNS.VAL")
#! Record("MGNT:L2B:1:ALLSOLNS",540,102,0,0,"MGNT:L2B:1:ALLSOLNS")
#! Field("MGNT:L2B:1:ALLSOLNS.VAL",16777215,0,"MGNT:L2B:1:ALLSOLNS.VAL")
#! Field("MGNT:L2B:1:ALLSOLNS.FLNK",16777215,1,"MGNT:L2B:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:L2B:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:L2B:1:KICKSWITCH")
}

record(seq, "MGNT:L2B:1:KICKSWITCH") {
  field(DOL1, "MGNT:L2B:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:KICKCTRL")
}

record(seq, "MGNT:L2B:1:ALLKICKSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:KICKCTRL",20,10,0,0,"MGNT:L2B:1:KICKCTRL")
#! Field("MGNT:L2B:1:KICKCTRL.FLNK",16777215,1,"MGNT:L2B:1:KICKCTRL.FLNK")
#! Link("MGNT:L2B:1:KICKCTRL.FLNK","MGNT:L2B:1:KICKSWITCH")
#! Field("MGNT:L2B:1:KICKCTRL.FFVL",16777215,1,"MGNT:L2B:1:KICKCTRL.FFVL")
#! Record("MGNT:L2B:1:KICKSWITCH",460,322,0,0,"MGNT:L2B:1:KICKSWITCH")
#! Field("MGNT:L2B:1:KICKSWITCH.DOL1",16777215,0,"MGNT:L2B:1:KICKSWITCH.DOL1")
#! Link("MGNT:L2B:1:KICKSWITCH.DOL1","MGNT:L2B:1:KICKCTRL.FFVL")
#! Field("MGNT:L2B:1:KICKSWITCH.LNK1",16777215,1,"MGNT:L2B:1:KICKSWITCH.LNK1")
#! Field("MGNT:L2B:1:KICKSWITCH.FLNK",16777215,1,"MGNT:L2B:1:KICKSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLKICKSGO",240,96,0,0,"MGNT:L2B:1:ALLKICKSGO")
#! Field("MGNT:L2B:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLKICKSGO.DOL1")
#! Field("MGNT:L2B:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLKICKSGO.LNK1")
#! Link("MGNT:L2B:1:ALLKICKSGO.LNK1","MGNT:L2B:1:ALLKICKS.VAL")
#! Record("MGNT:L2B:1:ALLKICKS",540,102,0,0,"MGNT:L2B:1:ALLKICKS")
#! Field("MGNT:L2B:1:ALLKICKS.VAL",16777215,0,"MGNT:L2B:1:ALLKICKS.VAL")
#! Field("MGNT:L2B:1:ALLKICKS.FLNK",16777215,1,"MGNT:L2B:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:L2B:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:L2B:1:SEXTSWITCH")
}

record(seq, "MGNT:L2B:1:SEXTSWITCH") {
  field(DOL1, "MGNT:L2B:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:L2B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L2B:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L2B:1:SEXTCTRL")
}

record(seq, "MGNT:L2B:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:L2B:1:ALLSTAR")
  field(LNK1, "MGNT:L2B:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:L2B:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L2B:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L2B:1:SEXTCTRL",20,10,0,0,"MGNT:L2B:1:SEXTCTRL")
#! Field("MGNT:L2B:1:SEXTCTRL.FLNK",16777215,1,"MGNT:L2B:1:SEXTCTRL.FLNK")
#! Link("MGNT:L2B:1:SEXTCTRL.FLNK","MGNT:L2B:1:SEXTSWITCH")
#! Field("MGNT:L2B:1:SEXTCTRL.FFVL",16777215,1,"MGNT:L2B:1:SEXTCTRL.FFVL")
#! Record("MGNT:L2B:1:SEXTSWITCH",460,322,0,0,"MGNT:L2B:1:SEXTSWITCH")
#! Field("MGNT:L2B:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:L2B:1:SEXTSWITCH.DOL1")
#! Link("MGNT:L2B:1:SEXTSWITCH.DOL1","MGNT:L2B:1:SEXTCTRL.FFVL")
#! Field("MGNT:L2B:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:L2B:1:SEXTSWITCH.LNK1")
#! Field("MGNT:L2B:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:L2B:1:SEXTSWITCH.FLNK")
#! Record("MGNT:L2B:1:ALLSEXTSGO",240,96,0,0,"MGNT:L2B:1:ALLSEXTSGO")
#! Field("MGNT:L2B:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:L2B:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:L2B:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:L2B:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:L2B:1:ALLSEXTSGO.LNK1","MGNT:L2B:1:ALLSEXTS.VAL")
#! Record("MGNT:L2B:1:ALLSEXTS",540,102,0,0,"MGNT:L2B:1:ALLSEXTS")
#! Field("MGNT:L2B:1:ALLSEXTS.VAL",16777215,0,"MGNT:L2B:1:ALLSEXTS.VAL")
#! Field("MGNT:L2B:1:ALLSEXTS.FLNK",16777215,1,"MGNT:L2B:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:L3B:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:L3B:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:L3B:1:CTRL CA PP")
  field(LNK2, "MGNT:L3B:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:L3B:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:L3B:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:L3B:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:L3B:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:L3B:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:L3B:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:L3B:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:L3B:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:L3B:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:L3B:1:ALLSWITCH")
}

record(seq, "MGNT:L3B:1:ALLSWITCH") {
  field(DOL1, "MGNT:L3B:1:CTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:CTRL")
}

record(bo, "MGNT:L3B:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:L3B:1:ALLSTARGO")
}

record(fanout, "MGNT:L3B:1:ALLSTARGO") {
  field(LNK1, "MGNT:L3B:1:ALLBENDSGO")
  field(LNK2, "MGNT:L3B:1:ALLBTRMSGO")
  field(LNK3, "MGNT:L3B:1:ALLLGPSSGO")
  field(LNK4, "MGNT:L3B:1:ALLQUADSGO")
  field(LNK5, "MGNT:L3B:1:ALLXCORSGO")
  field(LNK6, "MGNT:L3B:1:ALLYCORSGO")
  field(FLNK, "MGNT:L3B:1:ALLSTARGO_2")
}
record(fanout, "MGNT:L3B:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:L3B:1:ALLSOLNSGO")
  field(LNK2, "MGNT:L3B:1:ALLKICKSGO")
  field(LNK3, "MGNT:L3B:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:L3B:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:L3B:1:BENDSWITCH")
}

record(seq, "MGNT:L3B:1:BENDSWITCH") {
  field(DOL1, "MGNT:L3B:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:BENDCTRL")
}

record(seq, "MGNT:L3B:1:ALLBENDSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:BENDCTRL",20,10,0,0,"MGNT:L3B:1:BENDCTRL")
#! Field("MGNT:L3B:1:BENDCTRL.FLNK",16777215,1,"MGNT:L3B:1:BENDCTRL.FLNK")
#! Link("MGNT:L3B:1:BENDCTRL.FLNK","MGNT:L3B:1:BENDSWITCH")
#! Field("MGNT:L3B:1:BENDCTRL.FFVL",16777215,1,"MGNT:L3B:1:BENDCTRL.FFVL")
#! Record("MGNT:L3B:1:BENDSWITCH",460,322,0,0,"MGNT:L3B:1:BENDSWITCH")
#! Field("MGNT:L3B:1:BENDSWITCH.DOL1",16777215,0,"MGNT:L3B:1:BENDSWITCH.DOL1")
#! Link("MGNT:L3B:1:BENDSWITCH.DOL1","MGNT:L3B:1:BENDCTRL.FFVL")
#! Field("MGNT:L3B:1:BENDSWITCH.LNK1",16777215,1,"MGNT:L3B:1:BENDSWITCH.LNK1")
#! Field("MGNT:L3B:1:BENDSWITCH.FLNK",16777215,1,"MGNT:L3B:1:BENDSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLBENDSGO",240,96,0,0,"MGNT:L3B:1:ALLBENDSGO")
#! Field("MGNT:L3B:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLBENDSGO.DOL1")
#! Field("MGNT:L3B:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLBENDSGO.LNK1")
#! Link("MGNT:L3B:1:ALLBENDSGO.LNK1","MGNT:L3B:1:ALLBENDS.VAL")
#! Record("MGNT:L3B:1:ALLBENDS",540,102,0,0,"MGNT:L3B:1:ALLBENDS")
#! Field("MGNT:L3B:1:ALLBENDS.VAL",16777215,0,"MGNT:L3B:1:ALLBENDS.VAL")
#! Field("MGNT:L3B:1:ALLBENDS.FLNK",16777215,1,"MGNT:L3B:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:L3B:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L3B:1:BTRMSWITCH")
}

record(seq, "MGNT:L3B:1:BTRMSWITCH") {
  field(DOL1, "MGNT:L3B:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:BTRMCTRL")
}

record(seq, "MGNT:L3B:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:BTRMCTRL",20,10,0,0,"MGNT:L3B:1:BTRMCTRL")
#! Field("MGNT:L3B:1:BTRMCTRL.FLNK",16777215,1,"MGNT:L3B:1:BTRMCTRL.FLNK")
#! Link("MGNT:L3B:1:BTRMCTRL.FLNK","MGNT:L3B:1:BTRMSWITCH")
#! Field("MGNT:L3B:1:BTRMCTRL.FFVL",16777215,1,"MGNT:L3B:1:BTRMCTRL.FFVL")
#! Record("MGNT:L3B:1:BTRMSWITCH",460,322,0,0,"MGNT:L3B:1:BTRMSWITCH")
#! Field("MGNT:L3B:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:L3B:1:BTRMSWITCH.DOL1")
#! Link("MGNT:L3B:1:BTRMSWITCH.DOL1","MGNT:L3B:1:BTRMCTRL.FFVL")
#! Field("MGNT:L3B:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:L3B:1:BTRMSWITCH.LNK1")
#! Field("MGNT:L3B:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:L3B:1:BTRMSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLBTRMSGO",240,96,0,0,"MGNT:L3B:1:ALLBTRMSGO")
#! Field("MGNT:L3B:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:L3B:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:L3B:1:ALLBTRMSGO.LNK1","MGNT:L3B:1:ALLBTRMS.VAL")
#! Record("MGNT:L3B:1:ALLBTRMS",540,102,0,0,"MGNT:L3B:1:ALLBTRMS")
#! Field("MGNT:L3B:1:ALLBTRMS.VAL",16777215,0,"MGNT:L3B:1:ALLBTRMS.VAL")
#! Field("MGNT:L3B:1:ALLBTRMS.FLNK",16777215,1,"MGNT:L3B:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:L3B:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:L3B:1:LGPSSWITCH")
}

record(seq, "MGNT:L3B:1:LGPSSWITCH") {
  field(DOL1, "MGNT:L3B:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:LGPSCTRL")
}

record(seq, "MGNT:L3B:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:LGPSCTRL",20,10,0,0,"MGNT:L3B:1:LGPSCTRL")
#! Field("MGNT:L3B:1:LGPSCTRL.FLNK",16777215,1,"MGNT:L3B:1:LGPSCTRL.FLNK")
#! Link("MGNT:L3B:1:LGPSCTRL.FLNK","MGNT:L3B:1:LGPSSWITCH")
#! Field("MGNT:L3B:1:LGPSCTRL.FFVL",16777215,1,"MGNT:L3B:1:LGPSCTRL.FFVL")
#! Record("MGNT:L3B:1:LGPSSWITCH",460,322,0,0,"MGNT:L3B:1:LGPSSWITCH")
#! Field("MGNT:L3B:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:L3B:1:LGPSSWITCH.DOL1")
#! Link("MGNT:L3B:1:LGPSSWITCH.DOL1","MGNT:L3B:1:LGPSCTRL.FFVL")
#! Field("MGNT:L3B:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:L3B:1:LGPSSWITCH.LNK1")
#! Field("MGNT:L3B:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:L3B:1:LGPSSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLLGPSSGO",240,96,0,0,"MGNT:L3B:1:ALLLGPSSGO")
#! Field("MGNT:L3B:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:L3B:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:L3B:1:ALLLGPSSGO.LNK1","MGNT:L3B:1:ALLLGPSS.VAL")
#! Record("MGNT:L3B:1:ALLLGPSS",540,102,0,0,"MGNT:L3B:1:ALLLGPSS")
#! Field("MGNT:L3B:1:ALLLGPSS.VAL",16777215,0,"MGNT:L3B:1:ALLLGPSS.VAL")
#! Field("MGNT:L3B:1:ALLLGPSS.FLNK",16777215,1,"MGNT:L3B:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:L3B:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:L3B:1:QUADSWITCH")
}

record(seq, "MGNT:L3B:1:QUADSWITCH") {
  field(DOL1, "MGNT:L3B:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:QUADCTRL")
}

record(seq, "MGNT:L3B:1:ALLQUADSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:QUADCTRL",20,10,0,0,"MGNT:L3B:1:QUADCTRL")
#! Field("MGNT:L3B:1:QUADCTRL.FLNK",16777215,1,"MGNT:L3B:1:QUADCTRL.FLNK")
#! Link("MGNT:L3B:1:QUADCTRL.FLNK","MGNT:L3B:1:QUADSWITCH")
#! Field("MGNT:L3B:1:QUADCTRL.FFVL",16777215,1,"MGNT:L3B:1:QUADCTRL.FFVL")
#! Record("MGNT:L3B:1:QUADSWITCH",460,322,0,0,"MGNT:L3B:1:QUADSWITCH")
#! Field("MGNT:L3B:1:QUADSWITCH.DOL1",16777215,0,"MGNT:L3B:1:QUADSWITCH.DOL1")
#! Link("MGNT:L3B:1:QUADSWITCH.DOL1","MGNT:L3B:1:QUADCTRL.FFVL")
#! Field("MGNT:L3B:1:QUADSWITCH.LNK1",16777215,1,"MGNT:L3B:1:QUADSWITCH.LNK1")
#! Field("MGNT:L3B:1:QUADSWITCH.FLNK",16777215,1,"MGNT:L3B:1:QUADSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLQUADSGO",240,96,0,0,"MGNT:L3B:1:ALLQUADSGO")
#! Field("MGNT:L3B:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLQUADSGO.DOL1")
#! Field("MGNT:L3B:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLQUADSGO.LNK1")
#! Link("MGNT:L3B:1:ALLQUADSGO.LNK1","MGNT:L3B:1:ALLQUADS.VAL")
#! Record("MGNT:L3B:1:ALLQUADS",540,102,0,0,"MGNT:L3B:1:ALLQUADS")
#! Field("MGNT:L3B:1:ALLQUADS.VAL",16777215,0,"MGNT:L3B:1:ALLQUADS.VAL")
#! Field("MGNT:L3B:1:ALLQUADS.FLNK",16777215,1,"MGNT:L3B:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:L3B:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:L3B:1:XCORSWITCH")
}

record(seq, "MGNT:L3B:1:XCORSWITCH") {
  field(DOL1, "MGNT:L3B:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:XCORCTRL")
}

record(seq, "MGNT:L3B:1:ALLXCORSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:XCORCTRL",20,10,0,0,"MGNT:L3B:1:XCORCTRL")
#! Field("MGNT:L3B:1:XCORCTRL.FLNK",16777215,1,"MGNT:L3B:1:XCORCTRL.FLNK")
#! Link("MGNT:L3B:1:XCORCTRL.FLNK","MGNT:L3B:1:XCORSWITCH")
#! Field("MGNT:L3B:1:XCORCTRL.FFVL",16777215,1,"MGNT:L3B:1:XCORCTRL.FFVL")
#! Record("MGNT:L3B:1:XCORSWITCH",460,322,0,0,"MGNT:L3B:1:XCORSWITCH")
#! Field("MGNT:L3B:1:XCORSWITCH.DOL1",16777215,0,"MGNT:L3B:1:XCORSWITCH.DOL1")
#! Link("MGNT:L3B:1:XCORSWITCH.DOL1","MGNT:L3B:1:XCORCTRL.FFVL")
#! Field("MGNT:L3B:1:XCORSWITCH.LNK1",16777215,1,"MGNT:L3B:1:XCORSWITCH.LNK1")
#! Field("MGNT:L3B:1:XCORSWITCH.FLNK",16777215,1,"MGNT:L3B:1:XCORSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLXCORSGO",240,96,0,0,"MGNT:L3B:1:ALLXCORSGO")
#! Field("MGNT:L3B:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLXCORSGO.DOL1")
#! Field("MGNT:L3B:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLXCORSGO.LNK1")
#! Link("MGNT:L3B:1:ALLXCORSGO.LNK1","MGNT:L3B:1:ALLXCORS.VAL")
#! Record("MGNT:L3B:1:ALLXCORS",540,102,0,0,"MGNT:L3B:1:ALLXCORS")
#! Field("MGNT:L3B:1:ALLXCORS.VAL",16777215,0,"MGNT:L3B:1:ALLXCORS.VAL")
#! Field("MGNT:L3B:1:ALLXCORS.FLNK",16777215,1,"MGNT:L3B:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:L3B:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:L3B:1:YCORSWITCH")
}

record(seq, "MGNT:L3B:1:YCORSWITCH") {
  field(DOL1, "MGNT:L3B:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:YCORCTRL")
}

record(seq, "MGNT:L3B:1:ALLYCORSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:YCORCTRL",20,10,0,0,"MGNT:L3B:1:YCORCTRL")
#! Field("MGNT:L3B:1:YCORCTRL.FLNK",16777215,1,"MGNT:L3B:1:YCORCTRL.FLNK")
#! Link("MGNT:L3B:1:YCORCTRL.FLNK","MGNT:L3B:1:YCORSWITCH")
#! Field("MGNT:L3B:1:YCORCTRL.FFVL",16777215,1,"MGNT:L3B:1:YCORCTRL.FFVL")
#! Record("MGNT:L3B:1:YCORSWITCH",460,322,0,0,"MGNT:L3B:1:YCORSWITCH")
#! Field("MGNT:L3B:1:YCORSWITCH.DOL1",16777215,0,"MGNT:L3B:1:YCORSWITCH.DOL1")
#! Link("MGNT:L3B:1:YCORSWITCH.DOL1","MGNT:L3B:1:YCORCTRL.FFVL")
#! Field("MGNT:L3B:1:YCORSWITCH.LNK1",16777215,1,"MGNT:L3B:1:YCORSWITCH.LNK1")
#! Field("MGNT:L3B:1:YCORSWITCH.FLNK",16777215,1,"MGNT:L3B:1:YCORSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLYCORSGO",240,96,0,0,"MGNT:L3B:1:ALLYCORSGO")
#! Field("MGNT:L3B:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLYCORSGO.DOL1")
#! Field("MGNT:L3B:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLYCORSGO.LNK1")
#! Link("MGNT:L3B:1:ALLYCORSGO.LNK1","MGNT:L3B:1:ALLYCORS.VAL")
#! Record("MGNT:L3B:1:ALLYCORS",540,102,0,0,"MGNT:L3B:1:ALLYCORS")
#! Field("MGNT:L3B:1:ALLYCORS.VAL",16777215,0,"MGNT:L3B:1:ALLYCORS.VAL")
#! Field("MGNT:L3B:1:ALLYCORS.FLNK",16777215,1,"MGNT:L3B:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:L3B:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:L3B:1:SOLNSWITCH")
}

record(seq, "MGNT:L3B:1:SOLNSWITCH") {
  field(DOL1, "MGNT:L3B:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:SOLNCTRL")
}

record(seq, "MGNT:L3B:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:SOLNCTRL",20,10,0,0,"MGNT:L3B:1:SOLNCTRL")
#! Field("MGNT:L3B:1:SOLNCTRL.FLNK",16777215,1,"MGNT:L3B:1:SOLNCTRL.FLNK")
#! Link("MGNT:L3B:1:SOLNCTRL.FLNK","MGNT:L3B:1:SOLNSWITCH")
#! Field("MGNT:L3B:1:SOLNCTRL.FFVL",16777215,1,"MGNT:L3B:1:SOLNCTRL.FFVL")
#! Record("MGNT:L3B:1:SOLNSWITCH",460,322,0,0,"MGNT:L3B:1:SOLNSWITCH")
#! Field("MGNT:L3B:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:L3B:1:SOLNSWITCH.DOL1")
#! Link("MGNT:L3B:1:SOLNSWITCH.DOL1","MGNT:L3B:1:SOLNCTRL.FFVL")
#! Field("MGNT:L3B:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:L3B:1:SOLNSWITCH.LNK1")
#! Field("MGNT:L3B:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:L3B:1:SOLNSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLSOLNSGO",240,96,0,0,"MGNT:L3B:1:ALLSOLNSGO")
#! Field("MGNT:L3B:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:L3B:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:L3B:1:ALLSOLNSGO.LNK1","MGNT:L3B:1:ALLSOLNS.VAL")
#! Record("MGNT:L3B:1:ALLSOLNS",540,102,0,0,"MGNT:L3B:1:ALLSOLNS")
#! Field("MGNT:L3B:1:ALLSOLNS.VAL",16777215,0,"MGNT:L3B:1:ALLSOLNS.VAL")
#! Field("MGNT:L3B:1:ALLSOLNS.FLNK",16777215,1,"MGNT:L3B:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:L3B:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:L3B:1:KICKSWITCH")
}

record(seq, "MGNT:L3B:1:KICKSWITCH") {
  field(DOL1, "MGNT:L3B:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:KICKCTRL")
}

record(seq, "MGNT:L3B:1:ALLKICKSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:KICKCTRL",20,10,0,0,"MGNT:L3B:1:KICKCTRL")
#! Field("MGNT:L3B:1:KICKCTRL.FLNK",16777215,1,"MGNT:L3B:1:KICKCTRL.FLNK")
#! Link("MGNT:L3B:1:KICKCTRL.FLNK","MGNT:L3B:1:KICKSWITCH")
#! Field("MGNT:L3B:1:KICKCTRL.FFVL",16777215,1,"MGNT:L3B:1:KICKCTRL.FFVL")
#! Record("MGNT:L3B:1:KICKSWITCH",460,322,0,0,"MGNT:L3B:1:KICKSWITCH")
#! Field("MGNT:L3B:1:KICKSWITCH.DOL1",16777215,0,"MGNT:L3B:1:KICKSWITCH.DOL1")
#! Link("MGNT:L3B:1:KICKSWITCH.DOL1","MGNT:L3B:1:KICKCTRL.FFVL")
#! Field("MGNT:L3B:1:KICKSWITCH.LNK1",16777215,1,"MGNT:L3B:1:KICKSWITCH.LNK1")
#! Field("MGNT:L3B:1:KICKSWITCH.FLNK",16777215,1,"MGNT:L3B:1:KICKSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLKICKSGO",240,96,0,0,"MGNT:L3B:1:ALLKICKSGO")
#! Field("MGNT:L3B:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLKICKSGO.DOL1")
#! Field("MGNT:L3B:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLKICKSGO.LNK1")
#! Link("MGNT:L3B:1:ALLKICKSGO.LNK1","MGNT:L3B:1:ALLKICKS.VAL")
#! Record("MGNT:L3B:1:ALLKICKS",540,102,0,0,"MGNT:L3B:1:ALLKICKS")
#! Field("MGNT:L3B:1:ALLKICKS.VAL",16777215,0,"MGNT:L3B:1:ALLKICKS.VAL")
#! Field("MGNT:L3B:1:ALLKICKS.FLNK",16777215,1,"MGNT:L3B:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:L3B:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:L3B:1:SEXTSWITCH")
}

record(seq, "MGNT:L3B:1:SEXTSWITCH") {
  field(DOL1, "MGNT:L3B:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:L3B:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:L3B:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:L3B:1:SEXTCTRL")
}

record(seq, "MGNT:L3B:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:L3B:1:ALLSTAR")
  field(LNK1, "MGNT:L3B:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:L3B:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:L3B:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:L3B:1:SEXTCTRL",20,10,0,0,"MGNT:L3B:1:SEXTCTRL")
#! Field("MGNT:L3B:1:SEXTCTRL.FLNK",16777215,1,"MGNT:L3B:1:SEXTCTRL.FLNK")
#! Link("MGNT:L3B:1:SEXTCTRL.FLNK","MGNT:L3B:1:SEXTSWITCH")
#! Field("MGNT:L3B:1:SEXTCTRL.FFVL",16777215,1,"MGNT:L3B:1:SEXTCTRL.FFVL")
#! Record("MGNT:L3B:1:SEXTSWITCH",460,322,0,0,"MGNT:L3B:1:SEXTSWITCH")
#! Field("MGNT:L3B:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:L3B:1:SEXTSWITCH.DOL1")
#! Link("MGNT:L3B:1:SEXTSWITCH.DOL1","MGNT:L3B:1:SEXTCTRL.FFVL")
#! Field("MGNT:L3B:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:L3B:1:SEXTSWITCH.LNK1")
#! Field("MGNT:L3B:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:L3B:1:SEXTSWITCH.FLNK")
#! Record("MGNT:L3B:1:ALLSEXTSGO",240,96,0,0,"MGNT:L3B:1:ALLSEXTSGO")
#! Field("MGNT:L3B:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:L3B:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:L3B:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:L3B:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:L3B:1:ALLSEXTSGO.LNK1","MGNT:L3B:1:ALLSEXTS.VAL")
#! Record("MGNT:L3B:1:ALLSEXTS",540,102,0,0,"MGNT:L3B:1:ALLSEXTS")
#! Field("MGNT:L3B:1:ALLSEXTS.VAL",16777215,0,"MGNT:L3B:1:ALLSEXTS.VAL")
#! Field("MGNT:L3B:1:ALLSEXTS.FLNK",16777215,1,"MGNT:L3B:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:EXT:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:EXT:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:EXT:1:CTRL CA PP")
  field(LNK2, "MGNT:EXT:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:EXT:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:EXT:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:EXT:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:EXT:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:EXT:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:EXT:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:EXT:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:EXT:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:EXT:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:EXT:1:ALLSWITCH")
}

record(seq, "MGNT:EXT:1:ALLSWITCH") {
  field(DOL1, "MGNT:EXT:1:CTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:CTRL")
}

record(bo, "MGNT:EXT:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:EXT:1:ALLSTARGO")
}

record(fanout, "MGNT:EXT:1:ALLSTARGO") {
  field(LNK1, "MGNT:EXT:1:ALLBENDSGO")
  field(LNK2, "MGNT:EXT:1:ALLBTRMSGO")
  field(LNK3, "MGNT:EXT:1:ALLLGPSSGO")
  field(LNK4, "MGNT:EXT:1:ALLQUADSGO")
  field(LNK5, "MGNT:EXT:1:ALLXCORSGO")
  field(LNK6, "MGNT:EXT:1:ALLYCORSGO")
  field(FLNK, "MGNT:EXT:1:ALLSTARGO_2")
}
record(fanout, "MGNT:EXT:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:EXT:1:ALLSOLNSGO")
  field(LNK2, "MGNT:EXT:1:ALLKICKSGO")
  field(LNK3, "MGNT:EXT:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:EXT:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:EXT:1:BENDSWITCH")
}

record(seq, "MGNT:EXT:1:BENDSWITCH") {
  field(DOL1, "MGNT:EXT:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:BENDCTRL")
}

record(seq, "MGNT:EXT:1:ALLBENDSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:BENDCTRL",20,10,0,0,"MGNT:EXT:1:BENDCTRL")
#! Field("MGNT:EXT:1:BENDCTRL.FLNK",16777215,1,"MGNT:EXT:1:BENDCTRL.FLNK")
#! Link("MGNT:EXT:1:BENDCTRL.FLNK","MGNT:EXT:1:BENDSWITCH")
#! Field("MGNT:EXT:1:BENDCTRL.FFVL",16777215,1,"MGNT:EXT:1:BENDCTRL.FFVL")
#! Record("MGNT:EXT:1:BENDSWITCH",460,322,0,0,"MGNT:EXT:1:BENDSWITCH")
#! Field("MGNT:EXT:1:BENDSWITCH.DOL1",16777215,0,"MGNT:EXT:1:BENDSWITCH.DOL1")
#! Link("MGNT:EXT:1:BENDSWITCH.DOL1","MGNT:EXT:1:BENDCTRL.FFVL")
#! Field("MGNT:EXT:1:BENDSWITCH.LNK1",16777215,1,"MGNT:EXT:1:BENDSWITCH.LNK1")
#! Field("MGNT:EXT:1:BENDSWITCH.FLNK",16777215,1,"MGNT:EXT:1:BENDSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLBENDSGO",240,96,0,0,"MGNT:EXT:1:ALLBENDSGO")
#! Field("MGNT:EXT:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLBENDSGO.DOL1")
#! Field("MGNT:EXT:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLBENDSGO.LNK1")
#! Link("MGNT:EXT:1:ALLBENDSGO.LNK1","MGNT:EXT:1:ALLBENDS.VAL")
#! Record("MGNT:EXT:1:ALLBENDS",540,102,0,0,"MGNT:EXT:1:ALLBENDS")
#! Field("MGNT:EXT:1:ALLBENDS.VAL",16777215,0,"MGNT:EXT:1:ALLBENDS.VAL")
#! Field("MGNT:EXT:1:ALLBENDS.FLNK",16777215,1,"MGNT:EXT:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:EXT:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:EXT:1:BTRMSWITCH")
}

record(seq, "MGNT:EXT:1:BTRMSWITCH") {
  field(DOL1, "MGNT:EXT:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:BTRMCTRL")
}

record(seq, "MGNT:EXT:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:BTRMCTRL",20,10,0,0,"MGNT:EXT:1:BTRMCTRL")
#! Field("MGNT:EXT:1:BTRMCTRL.FLNK",16777215,1,"MGNT:EXT:1:BTRMCTRL.FLNK")
#! Link("MGNT:EXT:1:BTRMCTRL.FLNK","MGNT:EXT:1:BTRMSWITCH")
#! Field("MGNT:EXT:1:BTRMCTRL.FFVL",16777215,1,"MGNT:EXT:1:BTRMCTRL.FFVL")
#! Record("MGNT:EXT:1:BTRMSWITCH",460,322,0,0,"MGNT:EXT:1:BTRMSWITCH")
#! Field("MGNT:EXT:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:EXT:1:BTRMSWITCH.DOL1")
#! Link("MGNT:EXT:1:BTRMSWITCH.DOL1","MGNT:EXT:1:BTRMCTRL.FFVL")
#! Field("MGNT:EXT:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:EXT:1:BTRMSWITCH.LNK1")
#! Field("MGNT:EXT:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:EXT:1:BTRMSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLBTRMSGO",240,96,0,0,"MGNT:EXT:1:ALLBTRMSGO")
#! Field("MGNT:EXT:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:EXT:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:EXT:1:ALLBTRMSGO.LNK1","MGNT:EXT:1:ALLBTRMS.VAL")
#! Record("MGNT:EXT:1:ALLBTRMS",540,102,0,0,"MGNT:EXT:1:ALLBTRMS")
#! Field("MGNT:EXT:1:ALLBTRMS.VAL",16777215,0,"MGNT:EXT:1:ALLBTRMS.VAL")
#! Field("MGNT:EXT:1:ALLBTRMS.FLNK",16777215,1,"MGNT:EXT:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:EXT:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:EXT:1:LGPSSWITCH")
}

record(seq, "MGNT:EXT:1:LGPSSWITCH") {
  field(DOL1, "MGNT:EXT:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:LGPSCTRL")
}

record(seq, "MGNT:EXT:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:LGPSCTRL",20,10,0,0,"MGNT:EXT:1:LGPSCTRL")
#! Field("MGNT:EXT:1:LGPSCTRL.FLNK",16777215,1,"MGNT:EXT:1:LGPSCTRL.FLNK")
#! Link("MGNT:EXT:1:LGPSCTRL.FLNK","MGNT:EXT:1:LGPSSWITCH")
#! Field("MGNT:EXT:1:LGPSCTRL.FFVL",16777215,1,"MGNT:EXT:1:LGPSCTRL.FFVL")
#! Record("MGNT:EXT:1:LGPSSWITCH",460,322,0,0,"MGNT:EXT:1:LGPSSWITCH")
#! Field("MGNT:EXT:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:EXT:1:LGPSSWITCH.DOL1")
#! Link("MGNT:EXT:1:LGPSSWITCH.DOL1","MGNT:EXT:1:LGPSCTRL.FFVL")
#! Field("MGNT:EXT:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:EXT:1:LGPSSWITCH.LNK1")
#! Field("MGNT:EXT:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:EXT:1:LGPSSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLLGPSSGO",240,96,0,0,"MGNT:EXT:1:ALLLGPSSGO")
#! Field("MGNT:EXT:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:EXT:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:EXT:1:ALLLGPSSGO.LNK1","MGNT:EXT:1:ALLLGPSS.VAL")
#! Record("MGNT:EXT:1:ALLLGPSS",540,102,0,0,"MGNT:EXT:1:ALLLGPSS")
#! Field("MGNT:EXT:1:ALLLGPSS.VAL",16777215,0,"MGNT:EXT:1:ALLLGPSS.VAL")
#! Field("MGNT:EXT:1:ALLLGPSS.FLNK",16777215,1,"MGNT:EXT:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:EXT:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:EXT:1:QUADSWITCH")
}

record(seq, "MGNT:EXT:1:QUADSWITCH") {
  field(DOL1, "MGNT:EXT:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:QUADCTRL")
}

record(seq, "MGNT:EXT:1:ALLQUADSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:QUADCTRL",20,10,0,0,"MGNT:EXT:1:QUADCTRL")
#! Field("MGNT:EXT:1:QUADCTRL.FLNK",16777215,1,"MGNT:EXT:1:QUADCTRL.FLNK")
#! Link("MGNT:EXT:1:QUADCTRL.FLNK","MGNT:EXT:1:QUADSWITCH")
#! Field("MGNT:EXT:1:QUADCTRL.FFVL",16777215,1,"MGNT:EXT:1:QUADCTRL.FFVL")
#! Record("MGNT:EXT:1:QUADSWITCH",460,322,0,0,"MGNT:EXT:1:QUADSWITCH")
#! Field("MGNT:EXT:1:QUADSWITCH.DOL1",16777215,0,"MGNT:EXT:1:QUADSWITCH.DOL1")
#! Link("MGNT:EXT:1:QUADSWITCH.DOL1","MGNT:EXT:1:QUADCTRL.FFVL")
#! Field("MGNT:EXT:1:QUADSWITCH.LNK1",16777215,1,"MGNT:EXT:1:QUADSWITCH.LNK1")
#! Field("MGNT:EXT:1:QUADSWITCH.FLNK",16777215,1,"MGNT:EXT:1:QUADSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLQUADSGO",240,96,0,0,"MGNT:EXT:1:ALLQUADSGO")
#! Field("MGNT:EXT:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLQUADSGO.DOL1")
#! Field("MGNT:EXT:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLQUADSGO.LNK1")
#! Link("MGNT:EXT:1:ALLQUADSGO.LNK1","MGNT:EXT:1:ALLQUADS.VAL")
#! Record("MGNT:EXT:1:ALLQUADS",540,102,0,0,"MGNT:EXT:1:ALLQUADS")
#! Field("MGNT:EXT:1:ALLQUADS.VAL",16777215,0,"MGNT:EXT:1:ALLQUADS.VAL")
#! Field("MGNT:EXT:1:ALLQUADS.FLNK",16777215,1,"MGNT:EXT:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:EXT:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:EXT:1:XCORSWITCH")
}

record(seq, "MGNT:EXT:1:XCORSWITCH") {
  field(DOL1, "MGNT:EXT:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:XCORCTRL")
}

record(seq, "MGNT:EXT:1:ALLXCORSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:XCORCTRL",20,10,0,0,"MGNT:EXT:1:XCORCTRL")
#! Field("MGNT:EXT:1:XCORCTRL.FLNK",16777215,1,"MGNT:EXT:1:XCORCTRL.FLNK")
#! Link("MGNT:EXT:1:XCORCTRL.FLNK","MGNT:EXT:1:XCORSWITCH")
#! Field("MGNT:EXT:1:XCORCTRL.FFVL",16777215,1,"MGNT:EXT:1:XCORCTRL.FFVL")
#! Record("MGNT:EXT:1:XCORSWITCH",460,322,0,0,"MGNT:EXT:1:XCORSWITCH")
#! Field("MGNT:EXT:1:XCORSWITCH.DOL1",16777215,0,"MGNT:EXT:1:XCORSWITCH.DOL1")
#! Link("MGNT:EXT:1:XCORSWITCH.DOL1","MGNT:EXT:1:XCORCTRL.FFVL")
#! Field("MGNT:EXT:1:XCORSWITCH.LNK1",16777215,1,"MGNT:EXT:1:XCORSWITCH.LNK1")
#! Field("MGNT:EXT:1:XCORSWITCH.FLNK",16777215,1,"MGNT:EXT:1:XCORSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLXCORSGO",240,96,0,0,"MGNT:EXT:1:ALLXCORSGO")
#! Field("MGNT:EXT:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLXCORSGO.DOL1")
#! Field("MGNT:EXT:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLXCORSGO.LNK1")
#! Link("MGNT:EXT:1:ALLXCORSGO.LNK1","MGNT:EXT:1:ALLXCORS.VAL")
#! Record("MGNT:EXT:1:ALLXCORS",540,102,0,0,"MGNT:EXT:1:ALLXCORS")
#! Field("MGNT:EXT:1:ALLXCORS.VAL",16777215,0,"MGNT:EXT:1:ALLXCORS.VAL")
#! Field("MGNT:EXT:1:ALLXCORS.FLNK",16777215,1,"MGNT:EXT:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:EXT:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:EXT:1:YCORSWITCH")
}

record(seq, "MGNT:EXT:1:YCORSWITCH") {
  field(DOL1, "MGNT:EXT:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:YCORCTRL")
}

record(seq, "MGNT:EXT:1:ALLYCORSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:YCORCTRL",20,10,0,0,"MGNT:EXT:1:YCORCTRL")
#! Field("MGNT:EXT:1:YCORCTRL.FLNK",16777215,1,"MGNT:EXT:1:YCORCTRL.FLNK")
#! Link("MGNT:EXT:1:YCORCTRL.FLNK","MGNT:EXT:1:YCORSWITCH")
#! Field("MGNT:EXT:1:YCORCTRL.FFVL",16777215,1,"MGNT:EXT:1:YCORCTRL.FFVL")
#! Record("MGNT:EXT:1:YCORSWITCH",460,322,0,0,"MGNT:EXT:1:YCORSWITCH")
#! Field("MGNT:EXT:1:YCORSWITCH.DOL1",16777215,0,"MGNT:EXT:1:YCORSWITCH.DOL1")
#! Link("MGNT:EXT:1:YCORSWITCH.DOL1","MGNT:EXT:1:YCORCTRL.FFVL")
#! Field("MGNT:EXT:1:YCORSWITCH.LNK1",16777215,1,"MGNT:EXT:1:YCORSWITCH.LNK1")
#! Field("MGNT:EXT:1:YCORSWITCH.FLNK",16777215,1,"MGNT:EXT:1:YCORSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLYCORSGO",240,96,0,0,"MGNT:EXT:1:ALLYCORSGO")
#! Field("MGNT:EXT:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLYCORSGO.DOL1")
#! Field("MGNT:EXT:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLYCORSGO.LNK1")
#! Link("MGNT:EXT:1:ALLYCORSGO.LNK1","MGNT:EXT:1:ALLYCORS.VAL")
#! Record("MGNT:EXT:1:ALLYCORS",540,102,0,0,"MGNT:EXT:1:ALLYCORS")
#! Field("MGNT:EXT:1:ALLYCORS.VAL",16777215,0,"MGNT:EXT:1:ALLYCORS.VAL")
#! Field("MGNT:EXT:1:ALLYCORS.FLNK",16777215,1,"MGNT:EXT:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:EXT:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:EXT:1:SOLNSWITCH")
}

record(seq, "MGNT:EXT:1:SOLNSWITCH") {
  field(DOL1, "MGNT:EXT:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:SOLNCTRL")
}

record(seq, "MGNT:EXT:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:SOLNCTRL",20,10,0,0,"MGNT:EXT:1:SOLNCTRL")
#! Field("MGNT:EXT:1:SOLNCTRL.FLNK",16777215,1,"MGNT:EXT:1:SOLNCTRL.FLNK")
#! Link("MGNT:EXT:1:SOLNCTRL.FLNK","MGNT:EXT:1:SOLNSWITCH")
#! Field("MGNT:EXT:1:SOLNCTRL.FFVL",16777215,1,"MGNT:EXT:1:SOLNCTRL.FFVL")
#! Record("MGNT:EXT:1:SOLNSWITCH",460,322,0,0,"MGNT:EXT:1:SOLNSWITCH")
#! Field("MGNT:EXT:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:EXT:1:SOLNSWITCH.DOL1")
#! Link("MGNT:EXT:1:SOLNSWITCH.DOL1","MGNT:EXT:1:SOLNCTRL.FFVL")
#! Field("MGNT:EXT:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:EXT:1:SOLNSWITCH.LNK1")
#! Field("MGNT:EXT:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:EXT:1:SOLNSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLSOLNSGO",240,96,0,0,"MGNT:EXT:1:ALLSOLNSGO")
#! Field("MGNT:EXT:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:EXT:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:EXT:1:ALLSOLNSGO.LNK1","MGNT:EXT:1:ALLSOLNS.VAL")
#! Record("MGNT:EXT:1:ALLSOLNS",540,102,0,0,"MGNT:EXT:1:ALLSOLNS")
#! Field("MGNT:EXT:1:ALLSOLNS.VAL",16777215,0,"MGNT:EXT:1:ALLSOLNS.VAL")
#! Field("MGNT:EXT:1:ALLSOLNS.FLNK",16777215,1,"MGNT:EXT:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:EXT:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:EXT:1:KICKSWITCH")
}

record(seq, "MGNT:EXT:1:KICKSWITCH") {
  field(DOL1, "MGNT:EXT:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:KICKCTRL")
}

record(seq, "MGNT:EXT:1:ALLKICKSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:KICKCTRL",20,10,0,0,"MGNT:EXT:1:KICKCTRL")
#! Field("MGNT:EXT:1:KICKCTRL.FLNK",16777215,1,"MGNT:EXT:1:KICKCTRL.FLNK")
#! Link("MGNT:EXT:1:KICKCTRL.FLNK","MGNT:EXT:1:KICKSWITCH")
#! Field("MGNT:EXT:1:KICKCTRL.FFVL",16777215,1,"MGNT:EXT:1:KICKCTRL.FFVL")
#! Record("MGNT:EXT:1:KICKSWITCH",460,322,0,0,"MGNT:EXT:1:KICKSWITCH")
#! Field("MGNT:EXT:1:KICKSWITCH.DOL1",16777215,0,"MGNT:EXT:1:KICKSWITCH.DOL1")
#! Link("MGNT:EXT:1:KICKSWITCH.DOL1","MGNT:EXT:1:KICKCTRL.FFVL")
#! Field("MGNT:EXT:1:KICKSWITCH.LNK1",16777215,1,"MGNT:EXT:1:KICKSWITCH.LNK1")
#! Field("MGNT:EXT:1:KICKSWITCH.FLNK",16777215,1,"MGNT:EXT:1:KICKSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLKICKSGO",240,96,0,0,"MGNT:EXT:1:ALLKICKSGO")
#! Field("MGNT:EXT:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLKICKSGO.DOL1")
#! Field("MGNT:EXT:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLKICKSGO.LNK1")
#! Link("MGNT:EXT:1:ALLKICKSGO.LNK1","MGNT:EXT:1:ALLKICKS.VAL")
#! Record("MGNT:EXT:1:ALLKICKS",540,102,0,0,"MGNT:EXT:1:ALLKICKS")
#! Field("MGNT:EXT:1:ALLKICKS.VAL",16777215,0,"MGNT:EXT:1:ALLKICKS.VAL")
#! Field("MGNT:EXT:1:ALLKICKS.FLNK",16777215,1,"MGNT:EXT:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:EXT:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:EXT:1:SEXTSWITCH")
}

record(seq, "MGNT:EXT:1:SEXTSWITCH") {
  field(DOL1, "MGNT:EXT:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:EXT:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EXT:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EXT:1:SEXTCTRL")
}

record(seq, "MGNT:EXT:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:EXT:1:ALLSTAR")
  field(LNK1, "MGNT:EXT:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:EXT:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EXT:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EXT:1:SEXTCTRL",20,10,0,0,"MGNT:EXT:1:SEXTCTRL")
#! Field("MGNT:EXT:1:SEXTCTRL.FLNK",16777215,1,"MGNT:EXT:1:SEXTCTRL.FLNK")
#! Link("MGNT:EXT:1:SEXTCTRL.FLNK","MGNT:EXT:1:SEXTSWITCH")
#! Field("MGNT:EXT:1:SEXTCTRL.FFVL",16777215,1,"MGNT:EXT:1:SEXTCTRL.FFVL")
#! Record("MGNT:EXT:1:SEXTSWITCH",460,322,0,0,"MGNT:EXT:1:SEXTSWITCH")
#! Field("MGNT:EXT:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:EXT:1:SEXTSWITCH.DOL1")
#! Link("MGNT:EXT:1:SEXTSWITCH.DOL1","MGNT:EXT:1:SEXTCTRL.FFVL")
#! Field("MGNT:EXT:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:EXT:1:SEXTSWITCH.LNK1")
#! Field("MGNT:EXT:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:EXT:1:SEXTSWITCH.FLNK")
#! Record("MGNT:EXT:1:ALLSEXTSGO",240,96,0,0,"MGNT:EXT:1:ALLSEXTSGO")
#! Field("MGNT:EXT:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:EXT:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:EXT:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:EXT:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:EXT:1:ALLSEXTSGO.LNK1","MGNT:EXT:1:ALLSEXTS.VAL")
#! Record("MGNT:EXT:1:ALLSEXTS",540,102,0,0,"MGNT:EXT:1:ALLSEXTS")
#! Field("MGNT:EXT:1:ALLSEXTS.VAL",16777215,0,"MGNT:EXT:1:ALLSEXTS.VAL")
#! Field("MGNT:EXT:1:ALLSEXTS.FLNK",16777215,1,"MGNT:EXT:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:EMIT2:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:EMIT2:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:EMIT2:1:CTRL CA PP")
  field(LNK2, "MGNT:EMIT2:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:EMIT2:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:EMIT2:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:EMIT2:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:EMIT2:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:EMIT2:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:EMIT2:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:EMIT2:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:EMIT2:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:EMIT2:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:EMIT2:1:ALLSWITCH")
}

record(seq, "MGNT:EMIT2:1:ALLSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:CTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:CTRL")
}

record(bo, "MGNT:EMIT2:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLSTARGO")
}

record(fanout, "MGNT:EMIT2:1:ALLSTARGO") {
  field(LNK1, "MGNT:EMIT2:1:ALLBENDSGO")
  field(LNK2, "MGNT:EMIT2:1:ALLBTRMSGO")
  field(LNK3, "MGNT:EMIT2:1:ALLLGPSSGO")
  field(LNK4, "MGNT:EMIT2:1:ALLQUADSGO")
  field(LNK5, "MGNT:EMIT2:1:ALLXCORSGO")
  field(LNK6, "MGNT:EMIT2:1:ALLYCORSGO")
  field(FLNK, "MGNT:EMIT2:1:ALLSTARGO_2")
}
record(fanout, "MGNT:EMIT2:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:EMIT2:1:ALLSOLNSGO")
  field(LNK2, "MGNT:EMIT2:1:ALLKICKSGO")
  field(LNK3, "MGNT:EMIT2:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:EMIT2:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:EMIT2:1:BENDSWITCH")
}

record(seq, "MGNT:EMIT2:1:BENDSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:BENDCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLBENDSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:BENDCTRL",20,10,0,0,"MGNT:EMIT2:1:BENDCTRL")
#! Field("MGNT:EMIT2:1:BENDCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:BENDCTRL.FLNK")
#! Link("MGNT:EMIT2:1:BENDCTRL.FLNK","MGNT:EMIT2:1:BENDSWITCH")
#! Field("MGNT:EMIT2:1:BENDCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:BENDCTRL.FFVL")
#! Record("MGNT:EMIT2:1:BENDSWITCH",460,322,0,0,"MGNT:EMIT2:1:BENDSWITCH")
#! Field("MGNT:EMIT2:1:BENDSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:BENDSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:BENDSWITCH.DOL1","MGNT:EMIT2:1:BENDCTRL.FFVL")
#! Field("MGNT:EMIT2:1:BENDSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:BENDSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:BENDSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:BENDSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLBENDSGO",240,96,0,0,"MGNT:EMIT2:1:ALLBENDSGO")
#! Field("MGNT:EMIT2:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLBENDSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLBENDSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLBENDSGO.LNK1","MGNT:EMIT2:1:ALLBENDS.VAL")
#! Record("MGNT:EMIT2:1:ALLBENDS",540,102,0,0,"MGNT:EMIT2:1:ALLBENDS")
#! Field("MGNT:EMIT2:1:ALLBENDS.VAL",16777215,0,"MGNT:EMIT2:1:ALLBENDS.VAL")
#! Field("MGNT:EMIT2:1:ALLBENDS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:EMIT2:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:EMIT2:1:BTRMSWITCH")
}

record(seq, "MGNT:EMIT2:1:BTRMSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:BTRMCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:BTRMCTRL",20,10,0,0,"MGNT:EMIT2:1:BTRMCTRL")
#! Field("MGNT:EMIT2:1:BTRMCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:BTRMCTRL.FLNK")
#! Link("MGNT:EMIT2:1:BTRMCTRL.FLNK","MGNT:EMIT2:1:BTRMSWITCH")
#! Field("MGNT:EMIT2:1:BTRMCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:BTRMCTRL.FFVL")
#! Record("MGNT:EMIT2:1:BTRMSWITCH",460,322,0,0,"MGNT:EMIT2:1:BTRMSWITCH")
#! Field("MGNT:EMIT2:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:BTRMSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:BTRMSWITCH.DOL1","MGNT:EMIT2:1:BTRMCTRL.FFVL")
#! Field("MGNT:EMIT2:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:BTRMSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:BTRMSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLBTRMSGO",240,96,0,0,"MGNT:EMIT2:1:ALLBTRMSGO")
#! Field("MGNT:EMIT2:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLBTRMSGO.LNK1","MGNT:EMIT2:1:ALLBTRMS.VAL")
#! Record("MGNT:EMIT2:1:ALLBTRMS",540,102,0,0,"MGNT:EMIT2:1:ALLBTRMS")
#! Field("MGNT:EMIT2:1:ALLBTRMS.VAL",16777215,0,"MGNT:EMIT2:1:ALLBTRMS.VAL")
#! Field("MGNT:EMIT2:1:ALLBTRMS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:EMIT2:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:EMIT2:1:LGPSSWITCH")
}

record(seq, "MGNT:EMIT2:1:LGPSSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:LGPSCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:LGPSCTRL",20,10,0,0,"MGNT:EMIT2:1:LGPSCTRL")
#! Field("MGNT:EMIT2:1:LGPSCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:LGPSCTRL.FLNK")
#! Link("MGNT:EMIT2:1:LGPSCTRL.FLNK","MGNT:EMIT2:1:LGPSSWITCH")
#! Field("MGNT:EMIT2:1:LGPSCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:LGPSCTRL.FFVL")
#! Record("MGNT:EMIT2:1:LGPSSWITCH",460,322,0,0,"MGNT:EMIT2:1:LGPSSWITCH")
#! Field("MGNT:EMIT2:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:LGPSSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:LGPSSWITCH.DOL1","MGNT:EMIT2:1:LGPSCTRL.FFVL")
#! Field("MGNT:EMIT2:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:LGPSSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:LGPSSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLLGPSSGO",240,96,0,0,"MGNT:EMIT2:1:ALLLGPSSGO")
#! Field("MGNT:EMIT2:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLLGPSSGO.LNK1","MGNT:EMIT2:1:ALLLGPSS.VAL")
#! Record("MGNT:EMIT2:1:ALLLGPSS",540,102,0,0,"MGNT:EMIT2:1:ALLLGPSS")
#! Field("MGNT:EMIT2:1:ALLLGPSS.VAL",16777215,0,"MGNT:EMIT2:1:ALLLGPSS.VAL")
#! Field("MGNT:EMIT2:1:ALLLGPSS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:EMIT2:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:EMIT2:1:QUADSWITCH")
}

record(seq, "MGNT:EMIT2:1:QUADSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:QUADCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLQUADSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:QUADCTRL",20,10,0,0,"MGNT:EMIT2:1:QUADCTRL")
#! Field("MGNT:EMIT2:1:QUADCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:QUADCTRL.FLNK")
#! Link("MGNT:EMIT2:1:QUADCTRL.FLNK","MGNT:EMIT2:1:QUADSWITCH")
#! Field("MGNT:EMIT2:1:QUADCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:QUADCTRL.FFVL")
#! Record("MGNT:EMIT2:1:QUADSWITCH",460,322,0,0,"MGNT:EMIT2:1:QUADSWITCH")
#! Field("MGNT:EMIT2:1:QUADSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:QUADSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:QUADSWITCH.DOL1","MGNT:EMIT2:1:QUADCTRL.FFVL")
#! Field("MGNT:EMIT2:1:QUADSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:QUADSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:QUADSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:QUADSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLQUADSGO",240,96,0,0,"MGNT:EMIT2:1:ALLQUADSGO")
#! Field("MGNT:EMIT2:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLQUADSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLQUADSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLQUADSGO.LNK1","MGNT:EMIT2:1:ALLQUADS.VAL")
#! Record("MGNT:EMIT2:1:ALLQUADS",540,102,0,0,"MGNT:EMIT2:1:ALLQUADS")
#! Field("MGNT:EMIT2:1:ALLQUADS.VAL",16777215,0,"MGNT:EMIT2:1:ALLQUADS.VAL")
#! Field("MGNT:EMIT2:1:ALLQUADS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:EMIT2:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:EMIT2:1:XCORSWITCH")
}

record(seq, "MGNT:EMIT2:1:XCORSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:XCORCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLXCORSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:XCORCTRL",20,10,0,0,"MGNT:EMIT2:1:XCORCTRL")
#! Field("MGNT:EMIT2:1:XCORCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:XCORCTRL.FLNK")
#! Link("MGNT:EMIT2:1:XCORCTRL.FLNK","MGNT:EMIT2:1:XCORSWITCH")
#! Field("MGNT:EMIT2:1:XCORCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:XCORCTRL.FFVL")
#! Record("MGNT:EMIT2:1:XCORSWITCH",460,322,0,0,"MGNT:EMIT2:1:XCORSWITCH")
#! Field("MGNT:EMIT2:1:XCORSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:XCORSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:XCORSWITCH.DOL1","MGNT:EMIT2:1:XCORCTRL.FFVL")
#! Field("MGNT:EMIT2:1:XCORSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:XCORSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:XCORSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:XCORSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLXCORSGO",240,96,0,0,"MGNT:EMIT2:1:ALLXCORSGO")
#! Field("MGNT:EMIT2:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLXCORSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLXCORSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLXCORSGO.LNK1","MGNT:EMIT2:1:ALLXCORS.VAL")
#! Record("MGNT:EMIT2:1:ALLXCORS",540,102,0,0,"MGNT:EMIT2:1:ALLXCORS")
#! Field("MGNT:EMIT2:1:ALLXCORS.VAL",16777215,0,"MGNT:EMIT2:1:ALLXCORS.VAL")
#! Field("MGNT:EMIT2:1:ALLXCORS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:EMIT2:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:EMIT2:1:YCORSWITCH")
}

record(seq, "MGNT:EMIT2:1:YCORSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:YCORCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLYCORSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:YCORCTRL",20,10,0,0,"MGNT:EMIT2:1:YCORCTRL")
#! Field("MGNT:EMIT2:1:YCORCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:YCORCTRL.FLNK")
#! Link("MGNT:EMIT2:1:YCORCTRL.FLNK","MGNT:EMIT2:1:YCORSWITCH")
#! Field("MGNT:EMIT2:1:YCORCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:YCORCTRL.FFVL")
#! Record("MGNT:EMIT2:1:YCORSWITCH",460,322,0,0,"MGNT:EMIT2:1:YCORSWITCH")
#! Field("MGNT:EMIT2:1:YCORSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:YCORSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:YCORSWITCH.DOL1","MGNT:EMIT2:1:YCORCTRL.FFVL")
#! Field("MGNT:EMIT2:1:YCORSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:YCORSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:YCORSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:YCORSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLYCORSGO",240,96,0,0,"MGNT:EMIT2:1:ALLYCORSGO")
#! Field("MGNT:EMIT2:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLYCORSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLYCORSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLYCORSGO.LNK1","MGNT:EMIT2:1:ALLYCORS.VAL")
#! Record("MGNT:EMIT2:1:ALLYCORS",540,102,0,0,"MGNT:EMIT2:1:ALLYCORS")
#! Field("MGNT:EMIT2:1:ALLYCORS.VAL",16777215,0,"MGNT:EMIT2:1:ALLYCORS.VAL")
#! Field("MGNT:EMIT2:1:ALLYCORS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:EMIT2:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:EMIT2:1:SOLNSWITCH")
}

record(seq, "MGNT:EMIT2:1:SOLNSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:SOLNCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:SOLNCTRL",20,10,0,0,"MGNT:EMIT2:1:SOLNCTRL")
#! Field("MGNT:EMIT2:1:SOLNCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:SOLNCTRL.FLNK")
#! Link("MGNT:EMIT2:1:SOLNCTRL.FLNK","MGNT:EMIT2:1:SOLNSWITCH")
#! Field("MGNT:EMIT2:1:SOLNCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:SOLNCTRL.FFVL")
#! Record("MGNT:EMIT2:1:SOLNSWITCH",460,322,0,0,"MGNT:EMIT2:1:SOLNSWITCH")
#! Field("MGNT:EMIT2:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:SOLNSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:SOLNSWITCH.DOL1","MGNT:EMIT2:1:SOLNCTRL.FFVL")
#! Field("MGNT:EMIT2:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:SOLNSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:SOLNSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLSOLNSGO",240,96,0,0,"MGNT:EMIT2:1:ALLSOLNSGO")
#! Field("MGNT:EMIT2:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLSOLNSGO.LNK1","MGNT:EMIT2:1:ALLSOLNS.VAL")
#! Record("MGNT:EMIT2:1:ALLSOLNS",540,102,0,0,"MGNT:EMIT2:1:ALLSOLNS")
#! Field("MGNT:EMIT2:1:ALLSOLNS.VAL",16777215,0,"MGNT:EMIT2:1:ALLSOLNS.VAL")
#! Field("MGNT:EMIT2:1:ALLSOLNS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:EMIT2:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:EMIT2:1:KICKSWITCH")
}

record(seq, "MGNT:EMIT2:1:KICKSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:KICKCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLKICKSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:KICKCTRL",20,10,0,0,"MGNT:EMIT2:1:KICKCTRL")
#! Field("MGNT:EMIT2:1:KICKCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:KICKCTRL.FLNK")
#! Link("MGNT:EMIT2:1:KICKCTRL.FLNK","MGNT:EMIT2:1:KICKSWITCH")
#! Field("MGNT:EMIT2:1:KICKCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:KICKCTRL.FFVL")
#! Record("MGNT:EMIT2:1:KICKSWITCH",460,322,0,0,"MGNT:EMIT2:1:KICKSWITCH")
#! Field("MGNT:EMIT2:1:KICKSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:KICKSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:KICKSWITCH.DOL1","MGNT:EMIT2:1:KICKCTRL.FFVL")
#! Field("MGNT:EMIT2:1:KICKSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:KICKSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:KICKSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:KICKSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLKICKSGO",240,96,0,0,"MGNT:EMIT2:1:ALLKICKSGO")
#! Field("MGNT:EMIT2:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLKICKSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLKICKSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLKICKSGO.LNK1","MGNT:EMIT2:1:ALLKICKS.VAL")
#! Record("MGNT:EMIT2:1:ALLKICKS",540,102,0,0,"MGNT:EMIT2:1:ALLKICKS")
#! Field("MGNT:EMIT2:1:ALLKICKS.VAL",16777215,0,"MGNT:EMIT2:1:ALLKICKS.VAL")
#! Field("MGNT:EMIT2:1:ALLKICKS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:EMIT2:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:EMIT2:1:SEXTSWITCH")
}

record(seq, "MGNT:EMIT2:1:SEXTSWITCH") {
  field(DOL1, "MGNT:EMIT2:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:EMIT2:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:EMIT2:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:EMIT2:1:SEXTCTRL")
}

record(seq, "MGNT:EMIT2:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:EMIT2:1:ALLSTAR")
  field(LNK1, "MGNT:EMIT2:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:EMIT2:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:EMIT2:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:EMIT2:1:SEXTCTRL",20,10,0,0,"MGNT:EMIT2:1:SEXTCTRL")
#! Field("MGNT:EMIT2:1:SEXTCTRL.FLNK",16777215,1,"MGNT:EMIT2:1:SEXTCTRL.FLNK")
#! Link("MGNT:EMIT2:1:SEXTCTRL.FLNK","MGNT:EMIT2:1:SEXTSWITCH")
#! Field("MGNT:EMIT2:1:SEXTCTRL.FFVL",16777215,1,"MGNT:EMIT2:1:SEXTCTRL.FFVL")
#! Record("MGNT:EMIT2:1:SEXTSWITCH",460,322,0,0,"MGNT:EMIT2:1:SEXTSWITCH")
#! Field("MGNT:EMIT2:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:EMIT2:1:SEXTSWITCH.DOL1")
#! Link("MGNT:EMIT2:1:SEXTSWITCH.DOL1","MGNT:EMIT2:1:SEXTCTRL.FFVL")
#! Field("MGNT:EMIT2:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:EMIT2:1:SEXTSWITCH.LNK1")
#! Field("MGNT:EMIT2:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:EMIT2:1:SEXTSWITCH.FLNK")
#! Record("MGNT:EMIT2:1:ALLSEXTSGO",240,96,0,0,"MGNT:EMIT2:1:ALLSEXTSGO")
#! Field("MGNT:EMIT2:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:EMIT2:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:EMIT2:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:EMIT2:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:EMIT2:1:ALLSEXTSGO.LNK1","MGNT:EMIT2:1:ALLSEXTS.VAL")
#! Record("MGNT:EMIT2:1:ALLSEXTS",540,102,0,0,"MGNT:EMIT2:1:ALLSEXTS")
#! Field("MGNT:EMIT2:1:ALLSEXTS.VAL",16777215,0,"MGNT:EMIT2:1:ALLSEXTS.VAL")
#! Field("MGNT:EMIT2:1:ALLSEXTS.FLNK",16777215,1,"MGNT:EMIT2:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:DOG:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:DOG:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:DOG:1:CTRL CA PP")
  field(LNK2, "MGNT:DOG:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:DOG:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:DOG:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:DOG:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:DOG:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:DOG:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:DOG:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:DOG:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:DOG:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:DOG:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:DOG:1:ALLSWITCH")
}

record(seq, "MGNT:DOG:1:ALLSWITCH") {
  field(DOL1, "MGNT:DOG:1:CTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:CTRL")
}

record(bo, "MGNT:DOG:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:DOG:1:ALLSTARGO")
}

record(fanout, "MGNT:DOG:1:ALLSTARGO") {
  field(LNK1, "MGNT:DOG:1:ALLBENDSGO")
  field(LNK2, "MGNT:DOG:1:ALLBTRMSGO")
  field(LNK3, "MGNT:DOG:1:ALLLGPSSGO")
  field(LNK4, "MGNT:DOG:1:ALLQUADSGO")
  field(LNK5, "MGNT:DOG:1:ALLXCORSGO")
  field(LNK6, "MGNT:DOG:1:ALLYCORSGO")
  field(FLNK, "MGNT:DOG:1:ALLSTARGO_2")
}
record(fanout, "MGNT:DOG:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:DOG:1:ALLSOLNSGO")
  field(LNK2, "MGNT:DOG:1:ALLKICKSGO")
  field(LNK3, "MGNT:DOG:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:DOG:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:DOG:1:BENDSWITCH")
}

record(seq, "MGNT:DOG:1:BENDSWITCH") {
  field(DOL1, "MGNT:DOG:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:BENDCTRL")
}

record(seq, "MGNT:DOG:1:ALLBENDSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:BENDCTRL",20,10,0,0,"MGNT:DOG:1:BENDCTRL")
#! Field("MGNT:DOG:1:BENDCTRL.FLNK",16777215,1,"MGNT:DOG:1:BENDCTRL.FLNK")
#! Link("MGNT:DOG:1:BENDCTRL.FLNK","MGNT:DOG:1:BENDSWITCH")
#! Field("MGNT:DOG:1:BENDCTRL.FFVL",16777215,1,"MGNT:DOG:1:BENDCTRL.FFVL")
#! Record("MGNT:DOG:1:BENDSWITCH",460,322,0,0,"MGNT:DOG:1:BENDSWITCH")
#! Field("MGNT:DOG:1:BENDSWITCH.DOL1",16777215,0,"MGNT:DOG:1:BENDSWITCH.DOL1")
#! Link("MGNT:DOG:1:BENDSWITCH.DOL1","MGNT:DOG:1:BENDCTRL.FFVL")
#! Field("MGNT:DOG:1:BENDSWITCH.LNK1",16777215,1,"MGNT:DOG:1:BENDSWITCH.LNK1")
#! Field("MGNT:DOG:1:BENDSWITCH.FLNK",16777215,1,"MGNT:DOG:1:BENDSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLBENDSGO",240,96,0,0,"MGNT:DOG:1:ALLBENDSGO")
#! Field("MGNT:DOG:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLBENDSGO.DOL1")
#! Field("MGNT:DOG:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLBENDSGO.LNK1")
#! Link("MGNT:DOG:1:ALLBENDSGO.LNK1","MGNT:DOG:1:ALLBENDS.VAL")
#! Record("MGNT:DOG:1:ALLBENDS",540,102,0,0,"MGNT:DOG:1:ALLBENDS")
#! Field("MGNT:DOG:1:ALLBENDS.VAL",16777215,0,"MGNT:DOG:1:ALLBENDS.VAL")
#! Field("MGNT:DOG:1:ALLBENDS.FLNK",16777215,1,"MGNT:DOG:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:DOG:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DOG:1:BTRMSWITCH")
}

record(seq, "MGNT:DOG:1:BTRMSWITCH") {
  field(DOL1, "MGNT:DOG:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:BTRMCTRL")
}

record(seq, "MGNT:DOG:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:BTRMCTRL",20,10,0,0,"MGNT:DOG:1:BTRMCTRL")
#! Field("MGNT:DOG:1:BTRMCTRL.FLNK",16777215,1,"MGNT:DOG:1:BTRMCTRL.FLNK")
#! Link("MGNT:DOG:1:BTRMCTRL.FLNK","MGNT:DOG:1:BTRMSWITCH")
#! Field("MGNT:DOG:1:BTRMCTRL.FFVL",16777215,1,"MGNT:DOG:1:BTRMCTRL.FFVL")
#! Record("MGNT:DOG:1:BTRMSWITCH",460,322,0,0,"MGNT:DOG:1:BTRMSWITCH")
#! Field("MGNT:DOG:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:DOG:1:BTRMSWITCH.DOL1")
#! Link("MGNT:DOG:1:BTRMSWITCH.DOL1","MGNT:DOG:1:BTRMCTRL.FFVL")
#! Field("MGNT:DOG:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:DOG:1:BTRMSWITCH.LNK1")
#! Field("MGNT:DOG:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:DOG:1:BTRMSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLBTRMSGO",240,96,0,0,"MGNT:DOG:1:ALLBTRMSGO")
#! Field("MGNT:DOG:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:DOG:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:DOG:1:ALLBTRMSGO.LNK1","MGNT:DOG:1:ALLBTRMS.VAL")
#! Record("MGNT:DOG:1:ALLBTRMS",540,102,0,0,"MGNT:DOG:1:ALLBTRMS")
#! Field("MGNT:DOG:1:ALLBTRMS.VAL",16777215,0,"MGNT:DOG:1:ALLBTRMS.VAL")
#! Field("MGNT:DOG:1:ALLBTRMS.FLNK",16777215,1,"MGNT:DOG:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:DOG:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DOG:1:LGPSSWITCH")
}

record(seq, "MGNT:DOG:1:LGPSSWITCH") {
  field(DOL1, "MGNT:DOG:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:LGPSCTRL")
}

record(seq, "MGNT:DOG:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:LGPSCTRL",20,10,0,0,"MGNT:DOG:1:LGPSCTRL")
#! Field("MGNT:DOG:1:LGPSCTRL.FLNK",16777215,1,"MGNT:DOG:1:LGPSCTRL.FLNK")
#! Link("MGNT:DOG:1:LGPSCTRL.FLNK","MGNT:DOG:1:LGPSSWITCH")
#! Field("MGNT:DOG:1:LGPSCTRL.FFVL",16777215,1,"MGNT:DOG:1:LGPSCTRL.FFVL")
#! Record("MGNT:DOG:1:LGPSSWITCH",460,322,0,0,"MGNT:DOG:1:LGPSSWITCH")
#! Field("MGNT:DOG:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:DOG:1:LGPSSWITCH.DOL1")
#! Link("MGNT:DOG:1:LGPSSWITCH.DOL1","MGNT:DOG:1:LGPSCTRL.FFVL")
#! Field("MGNT:DOG:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:DOG:1:LGPSSWITCH.LNK1")
#! Field("MGNT:DOG:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:DOG:1:LGPSSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLLGPSSGO",240,96,0,0,"MGNT:DOG:1:ALLLGPSSGO")
#! Field("MGNT:DOG:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:DOG:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:DOG:1:ALLLGPSSGO.LNK1","MGNT:DOG:1:ALLLGPSS.VAL")
#! Record("MGNT:DOG:1:ALLLGPSS",540,102,0,0,"MGNT:DOG:1:ALLLGPSS")
#! Field("MGNT:DOG:1:ALLLGPSS.VAL",16777215,0,"MGNT:DOG:1:ALLLGPSS.VAL")
#! Field("MGNT:DOG:1:ALLLGPSS.FLNK",16777215,1,"MGNT:DOG:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:DOG:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:DOG:1:QUADSWITCH")
}

record(seq, "MGNT:DOG:1:QUADSWITCH") {
  field(DOL1, "MGNT:DOG:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:QUADCTRL")
}

record(seq, "MGNT:DOG:1:ALLQUADSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:QUADCTRL",20,10,0,0,"MGNT:DOG:1:QUADCTRL")
#! Field("MGNT:DOG:1:QUADCTRL.FLNK",16777215,1,"MGNT:DOG:1:QUADCTRL.FLNK")
#! Link("MGNT:DOG:1:QUADCTRL.FLNK","MGNT:DOG:1:QUADSWITCH")
#! Field("MGNT:DOG:1:QUADCTRL.FFVL",16777215,1,"MGNT:DOG:1:QUADCTRL.FFVL")
#! Record("MGNT:DOG:1:QUADSWITCH",460,322,0,0,"MGNT:DOG:1:QUADSWITCH")
#! Field("MGNT:DOG:1:QUADSWITCH.DOL1",16777215,0,"MGNT:DOG:1:QUADSWITCH.DOL1")
#! Link("MGNT:DOG:1:QUADSWITCH.DOL1","MGNT:DOG:1:QUADCTRL.FFVL")
#! Field("MGNT:DOG:1:QUADSWITCH.LNK1",16777215,1,"MGNT:DOG:1:QUADSWITCH.LNK1")
#! Field("MGNT:DOG:1:QUADSWITCH.FLNK",16777215,1,"MGNT:DOG:1:QUADSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLQUADSGO",240,96,0,0,"MGNT:DOG:1:ALLQUADSGO")
#! Field("MGNT:DOG:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLQUADSGO.DOL1")
#! Field("MGNT:DOG:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLQUADSGO.LNK1")
#! Link("MGNT:DOG:1:ALLQUADSGO.LNK1","MGNT:DOG:1:ALLQUADS.VAL")
#! Record("MGNT:DOG:1:ALLQUADS",540,102,0,0,"MGNT:DOG:1:ALLQUADS")
#! Field("MGNT:DOG:1:ALLQUADS.VAL",16777215,0,"MGNT:DOG:1:ALLQUADS.VAL")
#! Field("MGNT:DOG:1:ALLQUADS.FLNK",16777215,1,"MGNT:DOG:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:DOG:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:DOG:1:XCORSWITCH")
}

record(seq, "MGNT:DOG:1:XCORSWITCH") {
  field(DOL1, "MGNT:DOG:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:XCORCTRL")
}

record(seq, "MGNT:DOG:1:ALLXCORSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:XCORCTRL",20,10,0,0,"MGNT:DOG:1:XCORCTRL")
#! Field("MGNT:DOG:1:XCORCTRL.FLNK",16777215,1,"MGNT:DOG:1:XCORCTRL.FLNK")
#! Link("MGNT:DOG:1:XCORCTRL.FLNK","MGNT:DOG:1:XCORSWITCH")
#! Field("MGNT:DOG:1:XCORCTRL.FFVL",16777215,1,"MGNT:DOG:1:XCORCTRL.FFVL")
#! Record("MGNT:DOG:1:XCORSWITCH",460,322,0,0,"MGNT:DOG:1:XCORSWITCH")
#! Field("MGNT:DOG:1:XCORSWITCH.DOL1",16777215,0,"MGNT:DOG:1:XCORSWITCH.DOL1")
#! Link("MGNT:DOG:1:XCORSWITCH.DOL1","MGNT:DOG:1:XCORCTRL.FFVL")
#! Field("MGNT:DOG:1:XCORSWITCH.LNK1",16777215,1,"MGNT:DOG:1:XCORSWITCH.LNK1")
#! Field("MGNT:DOG:1:XCORSWITCH.FLNK",16777215,1,"MGNT:DOG:1:XCORSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLXCORSGO",240,96,0,0,"MGNT:DOG:1:ALLXCORSGO")
#! Field("MGNT:DOG:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLXCORSGO.DOL1")
#! Field("MGNT:DOG:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLXCORSGO.LNK1")
#! Link("MGNT:DOG:1:ALLXCORSGO.LNK1","MGNT:DOG:1:ALLXCORS.VAL")
#! Record("MGNT:DOG:1:ALLXCORS",540,102,0,0,"MGNT:DOG:1:ALLXCORS")
#! Field("MGNT:DOG:1:ALLXCORS.VAL",16777215,0,"MGNT:DOG:1:ALLXCORS.VAL")
#! Field("MGNT:DOG:1:ALLXCORS.FLNK",16777215,1,"MGNT:DOG:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:DOG:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:DOG:1:YCORSWITCH")
}

record(seq, "MGNT:DOG:1:YCORSWITCH") {
  field(DOL1, "MGNT:DOG:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:YCORCTRL")
}

record(seq, "MGNT:DOG:1:ALLYCORSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:YCORCTRL",20,10,0,0,"MGNT:DOG:1:YCORCTRL")
#! Field("MGNT:DOG:1:YCORCTRL.FLNK",16777215,1,"MGNT:DOG:1:YCORCTRL.FLNK")
#! Link("MGNT:DOG:1:YCORCTRL.FLNK","MGNT:DOG:1:YCORSWITCH")
#! Field("MGNT:DOG:1:YCORCTRL.FFVL",16777215,1,"MGNT:DOG:1:YCORCTRL.FFVL")
#! Record("MGNT:DOG:1:YCORSWITCH",460,322,0,0,"MGNT:DOG:1:YCORSWITCH")
#! Field("MGNT:DOG:1:YCORSWITCH.DOL1",16777215,0,"MGNT:DOG:1:YCORSWITCH.DOL1")
#! Link("MGNT:DOG:1:YCORSWITCH.DOL1","MGNT:DOG:1:YCORCTRL.FFVL")
#! Field("MGNT:DOG:1:YCORSWITCH.LNK1",16777215,1,"MGNT:DOG:1:YCORSWITCH.LNK1")
#! Field("MGNT:DOG:1:YCORSWITCH.FLNK",16777215,1,"MGNT:DOG:1:YCORSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLYCORSGO",240,96,0,0,"MGNT:DOG:1:ALLYCORSGO")
#! Field("MGNT:DOG:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLYCORSGO.DOL1")
#! Field("MGNT:DOG:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLYCORSGO.LNK1")
#! Link("MGNT:DOG:1:ALLYCORSGO.LNK1","MGNT:DOG:1:ALLYCORS.VAL")
#! Record("MGNT:DOG:1:ALLYCORS",540,102,0,0,"MGNT:DOG:1:ALLYCORS")
#! Field("MGNT:DOG:1:ALLYCORS.VAL",16777215,0,"MGNT:DOG:1:ALLYCORS.VAL")
#! Field("MGNT:DOG:1:ALLYCORS.FLNK",16777215,1,"MGNT:DOG:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:DOG:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:DOG:1:SOLNSWITCH")
}

record(seq, "MGNT:DOG:1:SOLNSWITCH") {
  field(DOL1, "MGNT:DOG:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:SOLNCTRL")
}

record(seq, "MGNT:DOG:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:SOLNCTRL",20,10,0,0,"MGNT:DOG:1:SOLNCTRL")
#! Field("MGNT:DOG:1:SOLNCTRL.FLNK",16777215,1,"MGNT:DOG:1:SOLNCTRL.FLNK")
#! Link("MGNT:DOG:1:SOLNCTRL.FLNK","MGNT:DOG:1:SOLNSWITCH")
#! Field("MGNT:DOG:1:SOLNCTRL.FFVL",16777215,1,"MGNT:DOG:1:SOLNCTRL.FFVL")
#! Record("MGNT:DOG:1:SOLNSWITCH",460,322,0,0,"MGNT:DOG:1:SOLNSWITCH")
#! Field("MGNT:DOG:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:DOG:1:SOLNSWITCH.DOL1")
#! Link("MGNT:DOG:1:SOLNSWITCH.DOL1","MGNT:DOG:1:SOLNCTRL.FFVL")
#! Field("MGNT:DOG:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:DOG:1:SOLNSWITCH.LNK1")
#! Field("MGNT:DOG:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:DOG:1:SOLNSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLSOLNSGO",240,96,0,0,"MGNT:DOG:1:ALLSOLNSGO")
#! Field("MGNT:DOG:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:DOG:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:DOG:1:ALLSOLNSGO.LNK1","MGNT:DOG:1:ALLSOLNS.VAL")
#! Record("MGNT:DOG:1:ALLSOLNS",540,102,0,0,"MGNT:DOG:1:ALLSOLNS")
#! Field("MGNT:DOG:1:ALLSOLNS.VAL",16777215,0,"MGNT:DOG:1:ALLSOLNS.VAL")
#! Field("MGNT:DOG:1:ALLSOLNS.FLNK",16777215,1,"MGNT:DOG:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:DOG:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:DOG:1:KICKSWITCH")
}

record(seq, "MGNT:DOG:1:KICKSWITCH") {
  field(DOL1, "MGNT:DOG:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:KICKCTRL")
}

record(seq, "MGNT:DOG:1:ALLKICKSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:KICKCTRL",20,10,0,0,"MGNT:DOG:1:KICKCTRL")
#! Field("MGNT:DOG:1:KICKCTRL.FLNK",16777215,1,"MGNT:DOG:1:KICKCTRL.FLNK")
#! Link("MGNT:DOG:1:KICKCTRL.FLNK","MGNT:DOG:1:KICKSWITCH")
#! Field("MGNT:DOG:1:KICKCTRL.FFVL",16777215,1,"MGNT:DOG:1:KICKCTRL.FFVL")
#! Record("MGNT:DOG:1:KICKSWITCH",460,322,0,0,"MGNT:DOG:1:KICKSWITCH")
#! Field("MGNT:DOG:1:KICKSWITCH.DOL1",16777215,0,"MGNT:DOG:1:KICKSWITCH.DOL1")
#! Link("MGNT:DOG:1:KICKSWITCH.DOL1","MGNT:DOG:1:KICKCTRL.FFVL")
#! Field("MGNT:DOG:1:KICKSWITCH.LNK1",16777215,1,"MGNT:DOG:1:KICKSWITCH.LNK1")
#! Field("MGNT:DOG:1:KICKSWITCH.FLNK",16777215,1,"MGNT:DOG:1:KICKSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLKICKSGO",240,96,0,0,"MGNT:DOG:1:ALLKICKSGO")
#! Field("MGNT:DOG:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLKICKSGO.DOL1")
#! Field("MGNT:DOG:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLKICKSGO.LNK1")
#! Link("MGNT:DOG:1:ALLKICKSGO.LNK1","MGNT:DOG:1:ALLKICKS.VAL")
#! Record("MGNT:DOG:1:ALLKICKS",540,102,0,0,"MGNT:DOG:1:ALLKICKS")
#! Field("MGNT:DOG:1:ALLKICKS.VAL",16777215,0,"MGNT:DOG:1:ALLKICKS.VAL")
#! Field("MGNT:DOG:1:ALLKICKS.FLNK",16777215,1,"MGNT:DOG:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:DOG:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:DOG:1:SEXTSWITCH")
}

record(seq, "MGNT:DOG:1:SEXTSWITCH") {
  field(DOL1, "MGNT:DOG:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:DOG:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DOG:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DOG:1:SEXTCTRL")
}

record(seq, "MGNT:DOG:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:DOG:1:ALLSTAR")
  field(LNK1, "MGNT:DOG:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:DOG:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DOG:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DOG:1:SEXTCTRL",20,10,0,0,"MGNT:DOG:1:SEXTCTRL")
#! Field("MGNT:DOG:1:SEXTCTRL.FLNK",16777215,1,"MGNT:DOG:1:SEXTCTRL.FLNK")
#! Link("MGNT:DOG:1:SEXTCTRL.FLNK","MGNT:DOG:1:SEXTSWITCH")
#! Field("MGNT:DOG:1:SEXTCTRL.FFVL",16777215,1,"MGNT:DOG:1:SEXTCTRL.FFVL")
#! Record("MGNT:DOG:1:SEXTSWITCH",460,322,0,0,"MGNT:DOG:1:SEXTSWITCH")
#! Field("MGNT:DOG:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:DOG:1:SEXTSWITCH.DOL1")
#! Link("MGNT:DOG:1:SEXTSWITCH.DOL1","MGNT:DOG:1:SEXTCTRL.FFVL")
#! Field("MGNT:DOG:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:DOG:1:SEXTSWITCH.LNK1")
#! Field("MGNT:DOG:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:DOG:1:SEXTSWITCH.FLNK")
#! Record("MGNT:DOG:1:ALLSEXTSGO",240,96,0,0,"MGNT:DOG:1:ALLSEXTSGO")
#! Field("MGNT:DOG:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:DOG:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:DOG:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:DOG:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:DOG:1:ALLSEXTSGO.LNK1","MGNT:DOG:1:ALLSEXTS.VAL")
#! Record("MGNT:DOG:1:ALLSEXTS",540,102,0,0,"MGNT:DOG:1:ALLSEXTS")
#! Field("MGNT:DOG:1:ALLSEXTS.VAL",16777215,0,"MGNT:DOG:1:ALLSEXTS.VAL")
#! Field("MGNT:DOG:1:ALLSEXTS.FLNK",16777215,1,"MGNT:DOG:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:BYP:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:BYP:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:BYP:1:CTRL CA PP")
  field(LNK2, "MGNT:BYP:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:BYP:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:BYP:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:BYP:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:BYP:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:BYP:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:BYP:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:BYP:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:BYP:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:BYP:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:BYP:1:ALLSWITCH")
}

record(seq, "MGNT:BYP:1:ALLSWITCH") {
  field(DOL1, "MGNT:BYP:1:CTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:CTRL")
}

record(bo, "MGNT:BYP:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:BYP:1:ALLSTARGO")
}

record(fanout, "MGNT:BYP:1:ALLSTARGO") {
  field(LNK1, "MGNT:BYP:1:ALLBENDSGO")
  field(LNK2, "MGNT:BYP:1:ALLBTRMSGO")
  field(LNK3, "MGNT:BYP:1:ALLLGPSSGO")
  field(LNK4, "MGNT:BYP:1:ALLQUADSGO")
  field(LNK5, "MGNT:BYP:1:ALLXCORSGO")
  field(LNK6, "MGNT:BYP:1:ALLYCORSGO")
  field(FLNK, "MGNT:BYP:1:ALLSTARGO_2")
}
record(fanout, "MGNT:BYP:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:BYP:1:ALLSOLNSGO")
  field(LNK2, "MGNT:BYP:1:ALLKICKSGO")
  field(LNK3, "MGNT:BYP:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:BYP:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:BYP:1:BENDSWITCH")
}

record(seq, "MGNT:BYP:1:BENDSWITCH") {
  field(DOL1, "MGNT:BYP:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:BENDCTRL")
}

record(seq, "MGNT:BYP:1:ALLBENDSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:BENDCTRL",20,10,0,0,"MGNT:BYP:1:BENDCTRL")
#! Field("MGNT:BYP:1:BENDCTRL.FLNK",16777215,1,"MGNT:BYP:1:BENDCTRL.FLNK")
#! Link("MGNT:BYP:1:BENDCTRL.FLNK","MGNT:BYP:1:BENDSWITCH")
#! Field("MGNT:BYP:1:BENDCTRL.FFVL",16777215,1,"MGNT:BYP:1:BENDCTRL.FFVL")
#! Record("MGNT:BYP:1:BENDSWITCH",460,322,0,0,"MGNT:BYP:1:BENDSWITCH")
#! Field("MGNT:BYP:1:BENDSWITCH.DOL1",16777215,0,"MGNT:BYP:1:BENDSWITCH.DOL1")
#! Link("MGNT:BYP:1:BENDSWITCH.DOL1","MGNT:BYP:1:BENDCTRL.FFVL")
#! Field("MGNT:BYP:1:BENDSWITCH.LNK1",16777215,1,"MGNT:BYP:1:BENDSWITCH.LNK1")
#! Field("MGNT:BYP:1:BENDSWITCH.FLNK",16777215,1,"MGNT:BYP:1:BENDSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLBENDSGO",240,96,0,0,"MGNT:BYP:1:ALLBENDSGO")
#! Field("MGNT:BYP:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLBENDSGO.DOL1")
#! Field("MGNT:BYP:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLBENDSGO.LNK1")
#! Link("MGNT:BYP:1:ALLBENDSGO.LNK1","MGNT:BYP:1:ALLBENDS.VAL")
#! Record("MGNT:BYP:1:ALLBENDS",540,102,0,0,"MGNT:BYP:1:ALLBENDS")
#! Field("MGNT:BYP:1:ALLBENDS.VAL",16777215,0,"MGNT:BYP:1:ALLBENDS.VAL")
#! Field("MGNT:BYP:1:ALLBENDS.FLNK",16777215,1,"MGNT:BYP:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:BYP:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BYP:1:BTRMSWITCH")
}

record(seq, "MGNT:BYP:1:BTRMSWITCH") {
  field(DOL1, "MGNT:BYP:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:BTRMCTRL")
}

record(seq, "MGNT:BYP:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:BTRMCTRL",20,10,0,0,"MGNT:BYP:1:BTRMCTRL")
#! Field("MGNT:BYP:1:BTRMCTRL.FLNK",16777215,1,"MGNT:BYP:1:BTRMCTRL.FLNK")
#! Link("MGNT:BYP:1:BTRMCTRL.FLNK","MGNT:BYP:1:BTRMSWITCH")
#! Field("MGNT:BYP:1:BTRMCTRL.FFVL",16777215,1,"MGNT:BYP:1:BTRMCTRL.FFVL")
#! Record("MGNT:BYP:1:BTRMSWITCH",460,322,0,0,"MGNT:BYP:1:BTRMSWITCH")
#! Field("MGNT:BYP:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:BYP:1:BTRMSWITCH.DOL1")
#! Link("MGNT:BYP:1:BTRMSWITCH.DOL1","MGNT:BYP:1:BTRMCTRL.FFVL")
#! Field("MGNT:BYP:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:BYP:1:BTRMSWITCH.LNK1")
#! Field("MGNT:BYP:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:BYP:1:BTRMSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLBTRMSGO",240,96,0,0,"MGNT:BYP:1:ALLBTRMSGO")
#! Field("MGNT:BYP:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:BYP:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:BYP:1:ALLBTRMSGO.LNK1","MGNT:BYP:1:ALLBTRMS.VAL")
#! Record("MGNT:BYP:1:ALLBTRMS",540,102,0,0,"MGNT:BYP:1:ALLBTRMS")
#! Field("MGNT:BYP:1:ALLBTRMS.VAL",16777215,0,"MGNT:BYP:1:ALLBTRMS.VAL")
#! Field("MGNT:BYP:1:ALLBTRMS.FLNK",16777215,1,"MGNT:BYP:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:BYP:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:BYP:1:LGPSSWITCH")
}

record(seq, "MGNT:BYP:1:LGPSSWITCH") {
  field(DOL1, "MGNT:BYP:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:LGPSCTRL")
}

record(seq, "MGNT:BYP:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:LGPSCTRL",20,10,0,0,"MGNT:BYP:1:LGPSCTRL")
#! Field("MGNT:BYP:1:LGPSCTRL.FLNK",16777215,1,"MGNT:BYP:1:LGPSCTRL.FLNK")
#! Link("MGNT:BYP:1:LGPSCTRL.FLNK","MGNT:BYP:1:LGPSSWITCH")
#! Field("MGNT:BYP:1:LGPSCTRL.FFVL",16777215,1,"MGNT:BYP:1:LGPSCTRL.FFVL")
#! Record("MGNT:BYP:1:LGPSSWITCH",460,322,0,0,"MGNT:BYP:1:LGPSSWITCH")
#! Field("MGNT:BYP:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:BYP:1:LGPSSWITCH.DOL1")
#! Link("MGNT:BYP:1:LGPSSWITCH.DOL1","MGNT:BYP:1:LGPSCTRL.FFVL")
#! Field("MGNT:BYP:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:BYP:1:LGPSSWITCH.LNK1")
#! Field("MGNT:BYP:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:BYP:1:LGPSSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLLGPSSGO",240,96,0,0,"MGNT:BYP:1:ALLLGPSSGO")
#! Field("MGNT:BYP:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:BYP:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:BYP:1:ALLLGPSSGO.LNK1","MGNT:BYP:1:ALLLGPSS.VAL")
#! Record("MGNT:BYP:1:ALLLGPSS",540,102,0,0,"MGNT:BYP:1:ALLLGPSS")
#! Field("MGNT:BYP:1:ALLLGPSS.VAL",16777215,0,"MGNT:BYP:1:ALLLGPSS.VAL")
#! Field("MGNT:BYP:1:ALLLGPSS.FLNK",16777215,1,"MGNT:BYP:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:BYP:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:BYP:1:QUADSWITCH")
}

record(seq, "MGNT:BYP:1:QUADSWITCH") {
  field(DOL1, "MGNT:BYP:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:QUADCTRL")
}

record(seq, "MGNT:BYP:1:ALLQUADSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:QUADCTRL",20,10,0,0,"MGNT:BYP:1:QUADCTRL")
#! Field("MGNT:BYP:1:QUADCTRL.FLNK",16777215,1,"MGNT:BYP:1:QUADCTRL.FLNK")
#! Link("MGNT:BYP:1:QUADCTRL.FLNK","MGNT:BYP:1:QUADSWITCH")
#! Field("MGNT:BYP:1:QUADCTRL.FFVL",16777215,1,"MGNT:BYP:1:QUADCTRL.FFVL")
#! Record("MGNT:BYP:1:QUADSWITCH",460,322,0,0,"MGNT:BYP:1:QUADSWITCH")
#! Field("MGNT:BYP:1:QUADSWITCH.DOL1",16777215,0,"MGNT:BYP:1:QUADSWITCH.DOL1")
#! Link("MGNT:BYP:1:QUADSWITCH.DOL1","MGNT:BYP:1:QUADCTRL.FFVL")
#! Field("MGNT:BYP:1:QUADSWITCH.LNK1",16777215,1,"MGNT:BYP:1:QUADSWITCH.LNK1")
#! Field("MGNT:BYP:1:QUADSWITCH.FLNK",16777215,1,"MGNT:BYP:1:QUADSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLQUADSGO",240,96,0,0,"MGNT:BYP:1:ALLQUADSGO")
#! Field("MGNT:BYP:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLQUADSGO.DOL1")
#! Field("MGNT:BYP:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLQUADSGO.LNK1")
#! Link("MGNT:BYP:1:ALLQUADSGO.LNK1","MGNT:BYP:1:ALLQUADS.VAL")
#! Record("MGNT:BYP:1:ALLQUADS",540,102,0,0,"MGNT:BYP:1:ALLQUADS")
#! Field("MGNT:BYP:1:ALLQUADS.VAL",16777215,0,"MGNT:BYP:1:ALLQUADS.VAL")
#! Field("MGNT:BYP:1:ALLQUADS.FLNK",16777215,1,"MGNT:BYP:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:BYP:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:BYP:1:XCORSWITCH")
}

record(seq, "MGNT:BYP:1:XCORSWITCH") {
  field(DOL1, "MGNT:BYP:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:XCORCTRL")
}

record(seq, "MGNT:BYP:1:ALLXCORSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:XCORCTRL",20,10,0,0,"MGNT:BYP:1:XCORCTRL")
#! Field("MGNT:BYP:1:XCORCTRL.FLNK",16777215,1,"MGNT:BYP:1:XCORCTRL.FLNK")
#! Link("MGNT:BYP:1:XCORCTRL.FLNK","MGNT:BYP:1:XCORSWITCH")
#! Field("MGNT:BYP:1:XCORCTRL.FFVL",16777215,1,"MGNT:BYP:1:XCORCTRL.FFVL")
#! Record("MGNT:BYP:1:XCORSWITCH",460,322,0,0,"MGNT:BYP:1:XCORSWITCH")
#! Field("MGNT:BYP:1:XCORSWITCH.DOL1",16777215,0,"MGNT:BYP:1:XCORSWITCH.DOL1")
#! Link("MGNT:BYP:1:XCORSWITCH.DOL1","MGNT:BYP:1:XCORCTRL.FFVL")
#! Field("MGNT:BYP:1:XCORSWITCH.LNK1",16777215,1,"MGNT:BYP:1:XCORSWITCH.LNK1")
#! Field("MGNT:BYP:1:XCORSWITCH.FLNK",16777215,1,"MGNT:BYP:1:XCORSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLXCORSGO",240,96,0,0,"MGNT:BYP:1:ALLXCORSGO")
#! Field("MGNT:BYP:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLXCORSGO.DOL1")
#! Field("MGNT:BYP:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLXCORSGO.LNK1")
#! Link("MGNT:BYP:1:ALLXCORSGO.LNK1","MGNT:BYP:1:ALLXCORS.VAL")
#! Record("MGNT:BYP:1:ALLXCORS",540,102,0,0,"MGNT:BYP:1:ALLXCORS")
#! Field("MGNT:BYP:1:ALLXCORS.VAL",16777215,0,"MGNT:BYP:1:ALLXCORS.VAL")
#! Field("MGNT:BYP:1:ALLXCORS.FLNK",16777215,1,"MGNT:BYP:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:BYP:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:BYP:1:YCORSWITCH")
}

record(seq, "MGNT:BYP:1:YCORSWITCH") {
  field(DOL1, "MGNT:BYP:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:YCORCTRL")
}

record(seq, "MGNT:BYP:1:ALLYCORSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:YCORCTRL",20,10,0,0,"MGNT:BYP:1:YCORCTRL")
#! Field("MGNT:BYP:1:YCORCTRL.FLNK",16777215,1,"MGNT:BYP:1:YCORCTRL.FLNK")
#! Link("MGNT:BYP:1:YCORCTRL.FLNK","MGNT:BYP:1:YCORSWITCH")
#! Field("MGNT:BYP:1:YCORCTRL.FFVL",16777215,1,"MGNT:BYP:1:YCORCTRL.FFVL")
#! Record("MGNT:BYP:1:YCORSWITCH",460,322,0,0,"MGNT:BYP:1:YCORSWITCH")
#! Field("MGNT:BYP:1:YCORSWITCH.DOL1",16777215,0,"MGNT:BYP:1:YCORSWITCH.DOL1")
#! Link("MGNT:BYP:1:YCORSWITCH.DOL1","MGNT:BYP:1:YCORCTRL.FFVL")
#! Field("MGNT:BYP:1:YCORSWITCH.LNK1",16777215,1,"MGNT:BYP:1:YCORSWITCH.LNK1")
#! Field("MGNT:BYP:1:YCORSWITCH.FLNK",16777215,1,"MGNT:BYP:1:YCORSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLYCORSGO",240,96,0,0,"MGNT:BYP:1:ALLYCORSGO")
#! Field("MGNT:BYP:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLYCORSGO.DOL1")
#! Field("MGNT:BYP:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLYCORSGO.LNK1")
#! Link("MGNT:BYP:1:ALLYCORSGO.LNK1","MGNT:BYP:1:ALLYCORS.VAL")
#! Record("MGNT:BYP:1:ALLYCORS",540,102,0,0,"MGNT:BYP:1:ALLYCORS")
#! Field("MGNT:BYP:1:ALLYCORS.VAL",16777215,0,"MGNT:BYP:1:ALLYCORS.VAL")
#! Field("MGNT:BYP:1:ALLYCORS.FLNK",16777215,1,"MGNT:BYP:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:BYP:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:BYP:1:SOLNSWITCH")
}

record(seq, "MGNT:BYP:1:SOLNSWITCH") {
  field(DOL1, "MGNT:BYP:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:SOLNCTRL")
}

record(seq, "MGNT:BYP:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:SOLNCTRL",20,10,0,0,"MGNT:BYP:1:SOLNCTRL")
#! Field("MGNT:BYP:1:SOLNCTRL.FLNK",16777215,1,"MGNT:BYP:1:SOLNCTRL.FLNK")
#! Link("MGNT:BYP:1:SOLNCTRL.FLNK","MGNT:BYP:1:SOLNSWITCH")
#! Field("MGNT:BYP:1:SOLNCTRL.FFVL",16777215,1,"MGNT:BYP:1:SOLNCTRL.FFVL")
#! Record("MGNT:BYP:1:SOLNSWITCH",460,322,0,0,"MGNT:BYP:1:SOLNSWITCH")
#! Field("MGNT:BYP:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:BYP:1:SOLNSWITCH.DOL1")
#! Link("MGNT:BYP:1:SOLNSWITCH.DOL1","MGNT:BYP:1:SOLNCTRL.FFVL")
#! Field("MGNT:BYP:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:BYP:1:SOLNSWITCH.LNK1")
#! Field("MGNT:BYP:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:BYP:1:SOLNSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLSOLNSGO",240,96,0,0,"MGNT:BYP:1:ALLSOLNSGO")
#! Field("MGNT:BYP:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:BYP:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:BYP:1:ALLSOLNSGO.LNK1","MGNT:BYP:1:ALLSOLNS.VAL")
#! Record("MGNT:BYP:1:ALLSOLNS",540,102,0,0,"MGNT:BYP:1:ALLSOLNS")
#! Field("MGNT:BYP:1:ALLSOLNS.VAL",16777215,0,"MGNT:BYP:1:ALLSOLNS.VAL")
#! Field("MGNT:BYP:1:ALLSOLNS.FLNK",16777215,1,"MGNT:BYP:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:BYP:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:BYP:1:KICKSWITCH")
}

record(seq, "MGNT:BYP:1:KICKSWITCH") {
  field(DOL1, "MGNT:BYP:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:KICKCTRL")
}

record(seq, "MGNT:BYP:1:ALLKICKSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:KICKCTRL",20,10,0,0,"MGNT:BYP:1:KICKCTRL")
#! Field("MGNT:BYP:1:KICKCTRL.FLNK",16777215,1,"MGNT:BYP:1:KICKCTRL.FLNK")
#! Link("MGNT:BYP:1:KICKCTRL.FLNK","MGNT:BYP:1:KICKSWITCH")
#! Field("MGNT:BYP:1:KICKCTRL.FFVL",16777215,1,"MGNT:BYP:1:KICKCTRL.FFVL")
#! Record("MGNT:BYP:1:KICKSWITCH",460,322,0,0,"MGNT:BYP:1:KICKSWITCH")
#! Field("MGNT:BYP:1:KICKSWITCH.DOL1",16777215,0,"MGNT:BYP:1:KICKSWITCH.DOL1")
#! Link("MGNT:BYP:1:KICKSWITCH.DOL1","MGNT:BYP:1:KICKCTRL.FFVL")
#! Field("MGNT:BYP:1:KICKSWITCH.LNK1",16777215,1,"MGNT:BYP:1:KICKSWITCH.LNK1")
#! Field("MGNT:BYP:1:KICKSWITCH.FLNK",16777215,1,"MGNT:BYP:1:KICKSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLKICKSGO",240,96,0,0,"MGNT:BYP:1:ALLKICKSGO")
#! Field("MGNT:BYP:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLKICKSGO.DOL1")
#! Field("MGNT:BYP:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLKICKSGO.LNK1")
#! Link("MGNT:BYP:1:ALLKICKSGO.LNK1","MGNT:BYP:1:ALLKICKS.VAL")
#! Record("MGNT:BYP:1:ALLKICKS",540,102,0,0,"MGNT:BYP:1:ALLKICKS")
#! Field("MGNT:BYP:1:ALLKICKS.VAL",16777215,0,"MGNT:BYP:1:ALLKICKS.VAL")
#! Field("MGNT:BYP:1:ALLKICKS.FLNK",16777215,1,"MGNT:BYP:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:BYP:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:BYP:1:SEXTSWITCH")
}

record(seq, "MGNT:BYP:1:SEXTSWITCH") {
  field(DOL1, "MGNT:BYP:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:BYP:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:BYP:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:BYP:1:SEXTCTRL")
}

record(seq, "MGNT:BYP:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:BYP:1:ALLSTAR")
  field(LNK1, "MGNT:BYP:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:BYP:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:BYP:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:BYP:1:SEXTCTRL",20,10,0,0,"MGNT:BYP:1:SEXTCTRL")
#! Field("MGNT:BYP:1:SEXTCTRL.FLNK",16777215,1,"MGNT:BYP:1:SEXTCTRL.FLNK")
#! Link("MGNT:BYP:1:SEXTCTRL.FLNK","MGNT:BYP:1:SEXTSWITCH")
#! Field("MGNT:BYP:1:SEXTCTRL.FFVL",16777215,1,"MGNT:BYP:1:SEXTCTRL.FFVL")
#! Record("MGNT:BYP:1:SEXTSWITCH",460,322,0,0,"MGNT:BYP:1:SEXTSWITCH")
#! Field("MGNT:BYP:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:BYP:1:SEXTSWITCH.DOL1")
#! Link("MGNT:BYP:1:SEXTSWITCH.DOL1","MGNT:BYP:1:SEXTCTRL.FFVL")
#! Field("MGNT:BYP:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:BYP:1:SEXTSWITCH.LNK1")
#! Field("MGNT:BYP:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:BYP:1:SEXTSWITCH.FLNK")
#! Record("MGNT:BYP:1:ALLSEXTSGO",240,96,0,0,"MGNT:BYP:1:ALLSEXTSGO")
#! Field("MGNT:BYP:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:BYP:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:BYP:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:BYP:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:BYP:1:ALLSEXTSGO.LNK1","MGNT:BYP:1:ALLSEXTS.VAL")
#! Record("MGNT:BYP:1:ALLSEXTS",540,102,0,0,"MGNT:BYP:1:ALLSEXTS")
#! Field("MGNT:BYP:1:ALLSEXTS.VAL",16777215,0,"MGNT:BYP:1:ALLSEXTS.VAL")
#! Field("MGNT:BYP:1:ALLSEXTS.FLNK",16777215,1,"MGNT:BYP:1:ALLSEXTS.FLNK")
record (seq, "MGNT:L0B:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:L0B:1:ALLKICKSSEL"){
}
record (seq, "MGNT:L0B:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:L0B:1:ALLBENDSSEL"){
}
record (seq, "MGNT:L0B:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:L0B:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:L0B:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L0B:1:ALLQUADS")
  field (LNK1, "QUAD:L0B:0185:SELECT PP NMS")
}
record (seq, "MGNT:L0B:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:L0B:1:ALLXCORS")
  field (LNK1, "XCOR:L0B:0185:SELECT PP NMS")
}
record (seq, "MGNT:L0B:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:L0B:1:ALLYCORS")
  field (LNK1, "YCOR:L0B:0185:SELECT PP NMS")
}
record (seq, "MGNT:L0B:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:L0B:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:L0B:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:L0B:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:L0B:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:L0B:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:L0B:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:L0B:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:L0B:1:ALLFUNCGO2")
}
record (seq, "MGNT:L0B:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:L0B:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:L0B:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:L0B:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:L0B:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:L0B:0185:ALLFUNCGO")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:L0B:0185:ALLFUNCGO")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L0B:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:L0B:0185:ALLFUNCGO")
  field (FLNK, "MGNT:L0B:1:CTRLCLEAR")
}
record (seq, "MGNT:HTR:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:HTR:1:ALLKICKSSEL"){
}
record (seq, "MGNT:HTR:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:HTR:1:ALLBENDSSEL"){
  field (DESC, "Select All BENDs")
  field (DOL1, "MGNT:HTR:1:ALLBENDS")
  field (LNK1,  "BEND:HTR:600:SELECT PP NMS")
}
record (seq, "MGNT:HTR:1:ALLBTRMSSEL"){
  field (DESC, "Select All BTRMs")
  field (DOL1, "MGNT:HTR:1:ALLBTRMS")
  field (DOL2, "MGNT:HTR:1:ALLBTRMS")
  field (DOL3, "MGNT:HTR:1:ALLBTRMS")
  field (LNK1, "BTRM:HTR:480:SELECT PP NMS")
  field (LNK2, "BTRM:HTR:700:SELECT PP NMS")
  field (LNK3, "BTRM:HTR:820:SELECT PP NMS")
}
record (seq, "MGNT:HTR:1:ALLLGPSSSEL"){
  field (DESC, "Select All LGPSs")
  field (DOL1, "MGNT:HTR:1:ALLLGPSS")
  field (DOL2, "MGNT:HTR:1:ALLLGPSS")
  field (LNK1, "LGPS:HTR:1:SELECT PP NMS")
  field (LNK2, "LGPS:HTR:2:SELECT PP NMS")
}
record (seq, "MGNT:HTR:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:HTR:1:ALLQUADS")
  field (DOL2, "MGNT:HTR:1:ALLQUADS")
  field (DOL3, "MGNT:HTR:1:ALLQUADS")
  field (DOL4, "MGNT:HTR:1:ALLQUADS")
  field (DOL5, "MGNT:HTR:1:ALLQUADS")
  field (DOL6, "MGNT:HTR:1:ALLQUADS")
  field (DOL7, "MGNT:HTR:1:ALLQUADS")
  field (DOL8, "MGNT:HTR:1:ALLQUADS")
  field (DOL9, "MGNT:HTR:1:ALLQUADS")
  field (DOLA, "MGNT:HTR:1:ALLQUADS")
  field (LNK1, "QUAD:HTR:120:SELECT PP NMS")
  field (LNK2, "QUAD:HTR:140:SELECT PP NMS")
  field (LNK3, "QUAD:HTR:300:SELECT PP NMS")
  field (LNK4, "QUAD:HTR:320:SELECT PP NMS")
  field (LNK5, "QUAD:HTR:365:SELECT PP NMS")
  field (LNK6, "QUAD:HTR:385:SELECT PP NMS")
  field (LNK7, "QUAD:HTR:440:SELECT PP NMS")
  field (LNK8, "QUAD:HTR:460:SELECT PP NMS")
  field (LNK9, "QUAD:HTR:830:SELECT PP NMS")
  field (LNKA, "QUAD:HTR:860:SELECT PP NMS")
  field (FLNK,  "MGNT:HTR:1:ALLQUADSSEL_2")
}
record (seq, "MGNT:HTR:1:ALLQUADSSEL_2"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:HTR:1:ALLQUADS")
  field (DOL2, "MGNT:HTR:1:ALLQUADS")
  field (LNK1, "QUAD:HTR:960:SELECT PP NMS")
  field (LNK2, "QUAD:HTR:980:SELECT PP NMS")
}
record (seq, "MGNT:HTR:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:HTR:1:ALLXCORS")
  field (DOL2, "MGNT:HTR:1:ALLXCORS")
  field (DOL3, "MGNT:HTR:1:ALLXCORS")
  field (DOL4, "MGNT:HTR:1:ALLXCORS")
  field (DOL5, "MGNT:HTR:1:ALLXCORS")
  field (DOL6, "MGNT:HTR:1:ALLXCORS")
  field (LNK1, "XCOR:HTR:148:SELECT PP NMS")
  field (LNK2, "XCOR:HTR:288:SELECT PP NMS")
  field (LNK3, "XCOR:HTR:396:SELECT PP NMS")
  field (LNK4, "XCOR:HTR:428:SELECT PP NMS")
  field (LNK5, "XCOR:HTR:848:SELECT PP NMS")
  field (LNK6, "XCOR:HTR:974:SELECT PP NMS")
}
record (seq, "MGNT:HTR:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:HTR:1:ALLYCORS")
  field (DOL2, "MGNT:HTR:1:ALLYCORS")
  field (DOL3, "MGNT:HTR:1:ALLYCORS")
  field (DOL4, "MGNT:HTR:1:ALLYCORS")
  field (DOL5, "MGNT:HTR:1:ALLYCORS")
  field (DOL6, "MGNT:HTR:1:ALLYCORS")
  field (LNK1, "YCOR:HTR:129:SELECT PP NMS")
  field (LNK2, "YCOR:HTR:309:SELECT PP NMS")
  field (LNK3, "YCOR:HTR:377:SELECT PP NMS")
  field (LNK4, "YCOR:HTR:451:SELECT PP NMS")
  field (LNK5, "YCOR:HTR:841:SELECT PP NMS")
  field (LNK6, "YCOR:HTR:951:SELECT PP NMS")
}
record (seq, "MGNT:HTR:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:HTR:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:HTR:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:HTR:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:HTR:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:HTR:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:HTR:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:HTR:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:HTR:1:ALLFUNCGO2")
}
record (seq, "MGNT:HTR:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:HTR:1:SOLNFUNCGO")
  field (LNK2, "MGNT:HTR:1:KICKFUNCGO")
  field (LNK3, "MGNT:HTR:1:SEXTFUNCGO")
  field (LNK4, "MGNT:HTR:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (LNK1, "BEND:HTR:600:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:HTR:480:ALLFUNCGO")
  field (LNK2, "BTRM:HTR:700:ALLFUNCGO")
  field (LNK3, "BTRM:HTR:820:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (LNK1, "LGPS:HTR:1:ALLFUNCGO")
  field (LNK2, "LGPS:HTR:2:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:HTR:120:ALLFUNCGO")
  field (LNK2, "QUAD:HTR:140:ALLFUNCGO")
  field (LNK3, "QUAD:HTR:300:ALLFUNCGO")
  field (LNK4, "QUAD:HTR:320:ALLFUNCGO")
  field (LNK5, "QUAD:HTR:365:ALLFUNCGO")
  field (LNK6, "QUAD:HTR:385:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:QUADFUNCGO_2")
}
record (fanout, "MGNT:HTR:1:QUADFUNCGO_2"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:HTR:440:ALLFUNCGO")
  field (LNK2, "QUAD:HTR:460:ALLFUNCGO")
  field (LNK3, "QUAD:HTR:830:ALLFUNCGO")
  field (LNK4, "QUAD:HTR:860:ALLFUNCGO")
  field (LNK5, "QUAD:HTR:960:ALLFUNCGO")
  field (LNK6, "QUAD:HTR:980:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}

record (fanout, "MGNT:HTR:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:HTR:148:ALLFUNCGO")
  field (LNK2, "XCOR:HTR:288:ALLFUNCGO")
  field (LNK3, "XCOR:HTR:396:ALLFUNCGO")
  field (LNK4, "XCOR:HTR:428:ALLFUNCGO")
  field (LNK5, "XCOR:HTR:848:ALLFUNCGO")
  field (LNK6, "XCOR:HTR:974:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (fanout, "MGNT:HTR:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:HTR:129:ALLFUNCGO")
  field (LNK2, "YCOR:HTR:309:ALLFUNCGO")
  field (LNK3, "YCOR:HTR:377:ALLFUNCGO")
  field (LNK4, "YCOR:HTR:451:ALLFUNCGO")
  field (LNK5, "YCOR:HTR:841:ALLFUNCGO")
  field (LNK6, "YCOR:HTR:951:ALLFUNCGO")
  field (FLNK, "MGNT:HTR:1:CTRLCLEAR")
}
record (seq, "MGNT:COL0:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:COL0:1:ALLKICKSSEL"){
}
record (seq, "MGNT:COL0:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:COL0:1:ALLBENDSSEL"){
}
record (seq, "MGNT:COL0:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:COL0:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:COL0:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:COL0:1:ALLQUADS")
  field (DOL2, "MGNT:COL0:1:ALLQUADS")
  field (DOL3, "MGNT:COL0:1:ALLQUADS")
  field (DOL4, "MGNT:COL0:1:ALLQUADS")
  field (DOL5, "MGNT:COL0:1:ALLQUADS")
  field (DOL6, "MGNT:COL0:1:ALLQUADS")
  field (DOL7, "MGNT:COL0:1:ALLQUADS")
  field (DOL8, "MGNT:COL0:1:ALLQUADS")
  field (DOL9, "MGNT:COL0:1:ALLQUADS")
  field (DOLA, "MGNT:COL0:1:ALLQUADS")
  field (LNK1, "QUAD:COL0:240:SELECT PP NMS")
  field (LNK2, "QUAD:COL0:260:SELECT PP NMS")
  field (LNK3, "QUAD:COL0:280:SELECT PP NMS")
  field (LNK4, "QUAD:COL0:320:SELECT PP NMS")
  field (LNK5, "QUAD:COL0:400:SELECT PP NMS")
  field (LNK6, "QUAD:COL0:480:SELECT PP NMS")
  field (LNK7, "QUAD:COL0:560:SELECT PP NMS")
  field (LNK8, "QUAD:COL0:640:SELECT PP NMS")
  field (LNK9, "QUAD:COL0:720:SELECT PP NMS")
  field (LNKA, "QUAD:COL0:800:SELECT PP NMS")
  field (FLNK,  "MGNT:COL0:1:ALLQUADSSEL_2")
}
record (seq, "MGNT:COL0:1:ALLQUADSSEL_2"){
  field (DOL1, "MGNT:COL0:1:ALLQUADS")
  field (DOL2, "MGNT:COL0:1:ALLQUADS")
  field (LNK1, "QUAD:COL0:880:SELECT PP NMS")
  field (LNK2, "QUAD:COL0:940:SELECT PP NMS")
}
record (seq, "MGNT:COL0:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:COL0:1:ALLXCORS")
  field (DOL2, "MGNT:COL0:1:ALLXCORS")
  field (DOL3, "MGNT:COL0:1:ALLXCORS")
  field (DOL4, "MGNT:COL0:1:ALLXCORS")
  field (DOL5, "MGNT:COL0:1:ALLXCORS")
  field (DOL6, "MGNT:COL0:1:ALLXCORS")
  field (LNK1, "XCOR:COL0:235:SELECT PP NMS")
  field (LNK2, "XCOR:COL0:328:SELECT PP NMS")
  field (LNK3, "XCOR:COL0:488:SELECT PP NMS")
  field (LNK4, "XCOR:COL0:648:SELECT PP NMS")
  field (LNK5, "XCOR:COL0:808:SELECT PP NMS")
  field (LNK6, "XCOR:COL0:932:SELECT PP NMS")
}
record (seq, "MGNT:COL0:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:COL0:1:ALLYCORS")
  field (DOL2, "MGNT:COL0:1:ALLYCORS")
  field (DOL3, "MGNT:COL0:1:ALLYCORS")
  field (DOL4, "MGNT:COL0:1:ALLYCORS")
  field (DOL5, "MGNT:COL0:1:ALLYCORS")
  field (DOL6, "MGNT:COL0:1:ALLYCORS")
  field (LNK1, "YCOR:COL0:235:SELECT PP NMS")
  field (LNK2, "YCOR:COL0:289:SELECT PP NMS")
  field (LNK3, "YCOR:COL0:409:SELECT PP NMS")
  field (LNK4, "YCOR:COL0:569:SELECT PP NMS")
  field (LNK5, "YCOR:COL0:729:SELECT PP NMS")
  field (LNK6, "YCOR:COL0:889:SELECT PP NMS")
}
record (seq, "MGNT:COL0:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:COL0:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:COL0:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:COL0:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:COL0:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:COL0:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:COL0:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:COL0:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:COL0:1:ALLFUNCGO2")
}
record (seq, "MGNT:COL0:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:COL0:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:COL0:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:COL0:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:COL0:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:COL0:240:ALLFUNCGO")
  field (LNK2, "QUAD:COL0:260:ALLFUNCGO")
  field (LNK3, "QUAD:COL0:280:ALLFUNCGO")
  field (LNK4, "QUAD:COL0:320:ALLFUNCGO")
  field (LNK5, "QUAD:COL0:400:ALLFUNCGO")
  field (LNK6, "QUAD:COL0:480:ALLFUNCGO")
  field (FLNK, "MGNT:COL0:1:QUADFUNCGO_2")
}
record (fanout, "MGNT:COL0:1:QUADFUNCGO_2"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:COL0:560:ALLFUNCGO")
  field (LNK2, "QUAD:COL0:640:ALLFUNCGO")
  field (LNK3, "QUAD:COL0:720:ALLFUNCGO")
  field (LNK4, "QUAD:COL0:800:ALLFUNCGO")
  field (LNK5, "QUAD:COL0:880:ALLFUNCGO")
  field (LNK6, "QUAD:COL0:940:ALLFUNCGO")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}

record (fanout, "MGNT:COL0:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:COL0:235:ALLFUNCGO")
  field (LNK2, "XCOR:COL0:328:ALLFUNCGO")
  field (LNK3, "XCOR:COL0:488:ALLFUNCGO")
  field (LNK4, "XCOR:COL0:648:ALLFUNCGO")
  field (LNK5, "XCOR:COL0:808:ALLFUNCGO")
  field (LNK6, "XCOR:COL0:932:ALLFUNCGO")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL0:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:COL0:235:ALLFUNCGO")
  field (LNK2, "YCOR:COL0:289:ALLFUNCGO")
  field (LNK3, "YCOR:COL0:409:ALLFUNCGO")
  field (LNK4, "YCOR:COL0:569:ALLFUNCGO")
  field (LNK5, "YCOR:COL0:729:ALLFUNCGO")
  field (LNK6, "YCOR:COL0:889:ALLFUNCGO")
  field (FLNK, "MGNT:COL0:1:CTRLCLEAR")
}
record (seq, "MGNT:DIAG0:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:DIAG0:1:ALLKICKSSEL"){
  field (DESC, "Select All KICKs")
  field (DOL1, "MGNT:DIAG0:1:ALLKICKS")
  field (LNK1, "KICK:DIAG0:110:SELECT PP NMS")
}
record (seq, "MGNT:DIAG0:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:DIAG0:1:ALLBENDSSEL"){
  field (DESC, "Select All BENDs")
  field (DOL1, "MGNT:DIAG0:1:ALLBENDS")
  field (DOL2, "MGNT:DIAG0:1:ALLBENDS")
  field (LNK1, "BEND:DIAG0:155:SELECT PP NMS")
  field (LNK2, "BEND:DIAG0:510:SELECT PP NMS")
}
record (seq, "MGNT:DIAG0:1:ALLBTRMSSEL"){
  field (DESC, "Select All BTRMs")
  field (DOL1, "MGNT:DIAG0:1:ALLBTRMS")
  field (LNK1, "BTRM:DIAG0:260:SELECT PP NMS")
}
record (seq, "MGNT:DIAG0:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:DIAG0:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL2, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL3, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL4, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL5, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL6, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL7, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL8, "MGNT:DIAG0:1:ALLQUADS")
  field (DOL9, "MGNT:DIAG0:1:ALLQUADS")
  field (DOLA, "MGNT:DIAG0:1:ALLQUADS")
  field (LNK1, "QUAD:DIAG0:190:SELECT PP NMS")
  field (LNK2, "QUAD:DIAG0:210:SELECT PP NMS")
  field (LNK3, "QUAD:DIAG0:230:SELECT PP NMS")
  field (LNK4, "QUAD:DIAG0:270:SELECT PP NMS")
  field (LNK5, "QUAD:DIAG0:285:SELECT PP NMS")
  field (LNK6, "QUAD:DIAG0:300:SELECT PP NMS")
  field (LNK7, "QUAD:DIAG0:360:SELECT PP NMS")
  field (LNK8, "QUAD:DIAG0:370:SELECT PP NMS")
  field (LNK9, "QUAD:DIAG0:390:SELECT PP NMS")
  field (LNKA, "QUAD:DIAG0:455:SELECT PP NMS")
  field (FLNK, "MGNT:DIAG0:1:ALLQUADSSEL_2")
}
record (seq, "MGNT:DIAG0:1:ALLQUADSSEL_2"){
  field (DOL1, "MGNT:DIAG0:1:ALLQUADS")
  field (LNK1, "QUAD:DIAG0:470:SELECT PP NMS")
}
record (seq, "MGNT:DIAG0:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:DIAG0:1:ALLXCORS")
  field (DOL2, "MGNT:DIAG0:1:ALLXCORS")
  field (DOL3, "MGNT:DIAG0:1:ALLXCORS")
  field (DOL4, "MGNT:DIAG0:1:ALLXCORS")
  field (DOL5, "MGNT:DIAG0:1:ALLXCORS")
  field (DOL6, "MGNT:DIAG0:1:ALLXCORS")
  field (DOL7, "MGNT:DIAG0:1:ALLXCORS")
  field (LNK1, "XCOR:DIAG0:178:SELECT PP NMS")
  field (LNK2, "XCOR:DIAG0:218:SELECT PP NMS")
  field (LNK3, "XCOR:DIAG0:280:SELECT PP NMS")
  field (LNK4, "XCOR:DIAG0:290:SELECT PP NMS")
  field (LNK5, "XCOR:DIAG0:380:SELECT PP NMS")
  field (LNK6, "XCOR:DIAG0:460:SELECT PP NMS")
  field (LNK7, "XCOR:DIAG0:340:SELECT PP NMS")
}
record (seq, "MGNT:DIAG0:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:DIAG0:1:ALLYCORS")
  field (DOL2, "MGNT:DIAG0:1:ALLYCORS")
  field (DOL3, "MGNT:DIAG0:1:ALLYCORS")
  field (DOL4, "MGNT:DIAG0:1:ALLYCORS")
  field (DOL5, "MGNT:DIAG0:1:ALLYCORS")
  field (DOL6, "MGNT:DIAG0:1:ALLYCORS")
  field (DOL7, "MGNT:DIAG0:1:ALLYCORS")
  field (LNK1, "YCOR:DIAG0:199:SELECT PP NMS")
  field (LNK2, "YCOR:DIAG0:247:SELECT PP NMS")
  field (LNK3, "YCOR:DIAG0:280:SELECT PP NMS")
  field (LNK4, "YCOR:DIAG0:290:SELECT PP NMS")
  field (LNK5, "YCOR:DIAG0:380:SELECT PP NMS")
  field (LNK6, "YCOR:DIAG0:460:SELECT PP NMS")
  field (LNK7, "YCOR:DIAG0:340:SELECT PP NMS")
}
record (seq, "MGNT:DIAG0:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:DIAG0:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:DIAG0:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:DIAG0:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:DIAG0:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:DIAG0:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:DIAG0:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:DIAG0:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:DIAG0:1:ALLFUNCGO2")
}
record (seq, "MGNT:DIAG0:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:DIAG0:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:DIAG0:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:DIAG0:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:DIAG0:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (LNK1, "KICK:DIAG0:110:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (LNK1, "BEND:DIAG0:155:ALLFUNCGO")
  field (LNK2, "BEND:DIAG0:510:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:DIAG0:260:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:DIAG0:190:ALLFUNCGO")
  field (LNK2, "QUAD:DIAG0:210:ALLFUNCGO")
  field (LNK3, "QUAD:DIAG0:230:ALLFUNCGO")
  field (LNK4, "QUAD:DIAG0:270:ALLFUNCGO")
  field (LNK5, "QUAD:DIAG0:285:ALLFUNCGO")
  field (LNK6, "QUAD:DIAG0:300:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:QUADFUNCGO_2")
}
record (fanout, "MGNT:DIAG0:1:QUADFUNCGO_2"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:DIAG0:360:ALLFUNCGO")
  field (LNK2, "QUAD:DIAG0:370:ALLFUNCGO")
  field (LNK3, "QUAD:DIAG0:390:ALLFUNCGO")
  field (LNK4, "QUAD:DIAG0:455:ALLFUNCGO")
  field (LNK5, "QUAD:DIAG0:470:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}

record (fanout, "MGNT:DIAG0:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:DIAG0:178:ALLFUNCGO")
  field (LNK2, "XCOR:DIAG0:218:ALLFUNCGO")
  field (LNK3, "XCOR:DIAG0:280:ALLFUNCGO")
  field (LNK4, "XCOR:DIAG0:290:ALLFUNCGO")
  field (LNK5, "XCOR:DIAG0:380:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:XCORFUNCGO_2")
}
record (fanout, "MGNT:DIAG0:1:XCORFUNCGO_2"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:DIAG0:460:ALLFUNCGO")
  field (LNK2, "XCOR:DIAG0:340:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}
record (fanout, "MGNT:DIAG0:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:DIAG0:199:ALLFUNCGO")
  field (LNK2, "YCOR:DIAG0:247:ALLFUNCGO")
  field (LNK3, "YCOR:DIAG0:280:ALLFUNCGO")
  field (LNK4, "YCOR:DIAG0:290:ALLFUNCGO")
  field (LNK5, "YCOR:DIAG0:380:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:YCORFUNCGO_2")
}
record (fanout, "MGNT:DIAG0:1:YCORFUNCGO_2"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:DIAG0:460:ALLFUNCGO")
  field (LNK2, "YCOR:DIAG0:340:ALLFUNCGO")
  field (FLNK, "MGNT:DIAG0:1:CTRLCLEAR")
}

record (seq, "MGNT:L1B:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:L1B:1:ALLKICKSSEL"){
}
record (seq, "MGNT:L1B:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:L1B:1:ALLBENDSSEL"){
}
record (seq, "MGNT:L1B:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:L1B:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:L1B:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L1B:1:ALLQUADS")
  field (DOL2, "MGNT:L1B:1:ALLQUADS")
  field (LNK1, "QUAD:L1B:0285:SELECT PP NMS")
  field (LNK2, "QUAD:L1B:0385:SELECT PP NMS")
}
record (seq, "MGNT:L1B:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:L1B:1:ALLXCORS")
  field (DOL2, "MGNT:L1B:1:ALLXCORS")
  field (LNK1, "XCOR:L1B:0285:SELECT PP NMS")
  field (LNK2, "XCOR:L1B:0385:SELECT PP NMS")
}
record (seq, "MGNT:L1B:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:L1B:1:ALLYCORS")
  field (DOL2, "MGNT:L1B:1:ALLYCORS")
  field (LNK1, "YCOR:L1B:0285:SELECT PP NMS")
  field (LNK2, "YCOR:L1B:0385:SELECT PP NMS")
}
record (seq, "MGNT:L1B:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:L1B:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:L1B:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:L1B:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:L1B:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:L1B:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:L1B:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:L1B:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:L1B:1:ALLFUNCGO2")
}
record (seq, "MGNT:L1B:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:L1B:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:L1B:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:L1B:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:L1B:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:L1B:0285:ALLFUNCGO")
  field (LNK2, "QUAD:L1B:0385:ALLFUNCGO")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:L1B:0285:ALLFUNCGO")
  field (LNK2, "XCOR:L1B:0385:ALLFUNCGO")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L1B:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:L1B:0285:ALLFUNCGO")
  field (LNK2, "YCOR:L1B:0385:ALLFUNCGO")
  field (FLNK, "MGNT:L1B:1:CTRLCLEAR")
}
record (seq, "MGNT:BC1B:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:BC1B:1:ALLKICKSSEL"){
}
record (seq, "MGNT:BC1B:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:BC1B:1:ALLBENDSSEL"){
  field (DESC, "Select All BENDs")
  field (DOL1, "MGNT:BC1B:1:ALLBENDS")
  field (LNK1, "BEND:BC1B:400:SELECT PP NMS")
}
record (seq, "MGNT:BC1B:1:ALLBTRMSSEL"){
  field (DESC, "Select All BTRMs")
  field (DOL1, "MGNT:BC1B:1:ALLBTRMS")
  field (DOL2, "MGNT:BC1B:1:ALLBTRMS")
  field (DOL3, "MGNT:BC1B:1:ALLBTRMS")
  field (LNK1, "BTRM:BC1B:200:SELECT PP NMS")
  field (LNK2, "BTRM:BC1B:600:SELECT PP NMS")
  field (LNK3, "BTRM:BC1B:800:SELECT PP NMS")
}
record (seq, "MGNT:BC1B:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:BC1B:1:ALLLGPSS")
  field (LNK1, "LGPS:BC1B:1:SELECT PP NMS")
}
record (seq, "MGNT:BC1B:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:BC1B:1:ALLQUADS")
  field (DOL2, "MGNT:BC1B:1:ALLQUADS")
  field (DOL3, "MGNT:BC1B:1:ALLQUADS")
  field (LNK1, "QUAD:BC1B:125:SELECT PP NMS")
  field (LNK2, "QUAD:BC1B:250:SELECT PP NMS")
  field (LNK3, "QUAD:BC1B:750:SELECT PP NMS")
}
record (seq, "MGNT:BC1B:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:BC1B:1:ALLXCORS")
  field (DOL2, "MGNT:BC1B:1:ALLXCORS")
  field (LNK1, "XCOR:BC1B:100:SELECT PP NMS")
  field (LNK2, "XCOR:BC1B:722:SELECT PP NMS")
}
record (seq, "MGNT:BC1B:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:BC1B:1:ALLYCORS")
  field (DOL2, "MGNT:BC1B:1:ALLYCORS")
  field (LNK1, "YCOR:BC1B:100:SELECT PP NMS")
  field (LNK2, "YCOR:BC1B:277:SELECT PP NMS")
}
record (seq, "MGNT:BC1B:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:BC1B:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:BC1B:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:BC1B:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:BC1B:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:BC1B:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:BC1B:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:BC1B:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:BC1B:1:ALLFUNCGO2")
}
record (seq, "MGNT:BC1B:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:BC1B:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:BC1B:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:BC1B:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:BC1B:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (LNK1, "BEND:BC1B:400:ALLFUNCGO")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:BC1B:200:ALLFUNCGO")
  field (LNK2, "BTRM:BC1B:600:ALLFUNCGO")
  field (LNK3, "BTRM:BC1B:800:ALLFUNCGO")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (LNK1, "LGPS:BC1B:1:ALLFUNCGO")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:BC1B:125:ALLFUNCGO")
  field (LNK2, "QUAD:BC1B:250:ALLFUNCGO")
  field (LNK3, "QUAD:BC1B:750:ALLFUNCGO")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:BC1B:100:ALLFUNCGO")
  field (LNK2, "XCOR:BC1B:722:ALLFUNCGO")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC1B:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:BC1B:100:ALLFUNCGO")
  field (LNK2, "YCOR:BC1B:277:ALLFUNCGO")
  field (FLNK, "MGNT:BC1B:1:CTRLCLEAR")
}
record (seq, "MGNT:BC2B:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:BC2B:1:ALLKICKSSEL"){
}
record (seq, "MGNT:BC2B:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:BC2B:1:ALLBENDSSEL"){
  field (DESC, "Select All BENDs")
  field (DOL1, "MGNT:BC2B:1:ALLBENDS")
  field (LNK1, "BEND:BC2B:500:SELECT PP NMS")
}
record (seq, "MGNT:BC2B:1:ALLBTRMSSEL"){
  field (DESC, "Select All BTRMs")
  field (DOL1, "MGNT:BC2B:1:ALLBTRMS")
  field (DOL2, "MGNT:BC2B:1:ALLBTRMS")
  field (DOL3, "MGNT:BC2B:1:ALLBTRMS")
  field (LNK1, "BTRM:BC2B:200:SELECT PP NMS")
  field (LNK2, "BTRM:BC2B:600:SELECT PP NMS")
  field (LNK3, "BTRM:BC2B:900:SELECT PP NMS")
}
record (seq, "MGNT:BC2B:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:BC2B:1:ALLLGPSS")
  field (LNK1, "LGPS:BC2B:1:SELECT PP NMS")
}
record (seq, "MGNT:BC2B:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:BC2B:1:ALLQUADS")
  field (DOL2, "MGNT:BC2B:1:ALLQUADS")
  field (DOL3, "MGNT:BC2B:1:ALLQUADS")
  field (LNK1, "QUAD:BC2B:150:SELECT PP NMS")
  field (LNK2, "QUAD:BC2B:250:SELECT PP NMS")
  field (LNK3, "QUAD:BC2B:850:SELECT PP NMS")
}
record (seq, "MGNT:BC2B:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:BC2B:1:ALLXCORS")
  field (LNK1, "XCOR:BC2B:126:SELECT PP NMS")
}
record (seq, "MGNT:BC2B:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:BC2B:1:ALLYCORS")
  field (LNK1, "YCOR:BC2B:137:SELECT PP NMS")
}
record (seq, "MGNT:BC2B:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:BC2B:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:BC2B:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:BC2B:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:BC2B:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:BC2B:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:BC2B:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:BC2B:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:BC2B:1:ALLFUNCGO2")
}
record (seq, "MGNT:BC2B:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:BC2B:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:BC2B:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:BC2B:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:BC2B:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (LNK1, "BEND:BC2B:500:ALLFUNCGO")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:BC2B:200:ALLFUNCGO")
  field (LNK2, "BTRM:BC2B:600:ALLFUNCGO")
  field (LNK3, "BTRM:BC2B:900:ALLFUNCGO")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (LNK1, "LGPS:BC2B:1:ALLFUNCGO")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:BC2B:150:ALLFUNCGO")
  field (LNK2, "QUAD:BC2B:250:ALLFUNCGO")
  field (LNK3, "QUAD:BC2B:850:ALLFUNCGO")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:BC2B:126:ALLFUNCGO")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:BC2B:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:BC2B:137:ALLFUNCGO")
  field (FLNK, "MGNT:BC2B:1:CTRLCLEAR")
}
record (seq, "MGNT:COL1:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:COL1:1:ALLKICKSSEL"){
}
record (seq, "MGNT:COL1:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:COL1:1:ALLBENDSSEL"){
}
record (seq, "MGNT:COL1:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:COL1:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:COL1:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:COL1:1:ALLQUADS")
  field (DOL2, "MGNT:COL1:1:ALLQUADS")
  field (DOL3, "MGNT:COL1:1:ALLQUADS")
  field (DOL4, "MGNT:COL1:1:ALLQUADS")
  field (DOL5, "MGNT:COL1:1:ALLQUADS")
  field (DOL6, "MGNT:COL1:1:ALLQUADS")
  field (DOL7, "MGNT:COL1:1:ALLQUADS")
  field (DOL8, "MGNT:COL1:1:ALLQUADS")
  field (DOL9, "MGNT:COL1:1:ALLQUADS")
  field (DOLA, "MGNT:COL1:1:ALLQUADS")
  field (LNK1, "QUAD:COL1:120:SELECT PP NMS")
  field (LNK2, "QUAD:COL1:260:SELECT PP NMS")
  field (LNK3, "QUAD:COL1:280:SELECT PP NMS")
  field (LNK4, "QUAD:COL1:320:SELECT PP NMS")
  field (LNK5, "QUAD:COL1:400:SELECT PP NMS")
  field (LNK6, "QUAD:COL1:480:SELECT PP NMS")
  field (LNK7, "QUAD:COL1:560:SELECT PP NMS")
  field (LNK8, "QUAD:COL1:640:SELECT PP NMS")
  field (LNK9, "QUAD:COL1:720:SELECT PP NMS")
  field (LNKA, "QUAD:COL1:800:SELECT PP NMS")
  field (FLNK,  "MGNT:COL1:1:ALLQUADSSEL_2")
}
record (seq, "MGNT:COL1:1:ALLQUADSSEL_2"){
  field (DOL1, "MGNT:COL1:1:ALLQUADS")
  field (DOL2, "MGNT:COL1:1:ALLQUADS")
  field (LNK1, "QUAD:COL1:880:SELECT PP NMS")
  field (LNK2, "QUAD:COL1:960:SELECT PP NMS")
}
record (seq, "MGNT:COL1:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:COL1:1:ALLXCORS")
  field (DOL2, "MGNT:COL1:1:ALLXCORS")
  field (DOL3, "MGNT:COL1:1:ALLXCORS")
  field (DOL4, "MGNT:COL1:1:ALLXCORS")
  field (DOL5, "MGNT:COL1:1:ALLXCORS")
  field (DOL6, "MGNT:COL1:1:ALLXCORS")
  field (LNK1, "XCOR:COL1:128:SELECT PP NMS")
  field (LNK2, "XCOR:COL1:328:SELECT PP NMS")
  field (LNK3, "XCOR:COL1:488:SELECT PP NMS")
  field (LNK4, "XCOR:COL1:648:SELECT PP NMS")
  field (LNK5, "XCOR:COL1:808:SELECT PP NMS")
  field (LNK6, "XCOR:COL1:968:SELECT PP NMS")
}
record (seq, "MGNT:COL1:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:COL1:1:ALLYCORS")
  field (DOL2, "MGNT:COL1:1:ALLYCORS")
  field (DOL3, "MGNT:COL1:1:ALLYCORS")
  field (DOL4, "MGNT:COL1:1:ALLYCORS")
  field (DOL5, "MGNT:COL1:1:ALLYCORS")
  field (LNK1, "YCOR:COL1:129:SELECT PP NMS")
  field (LNK2, "YCOR:COL1:409:SELECT PP NMS")
  field (LNK3, "YCOR:COL1:569:SELECT PP NMS")
  field (LNK4, "YCOR:COL1:729:SELECT PP NMS")
  field (LNK5, "YCOR:COL1:889:SELECT PP NMS")
}
record (seq, "MGNT:COL1:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:COL1:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:COL1:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:COL1:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:COL1:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:COL1:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:COL1:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:COL1:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:COL1:1:ALLFUNCGO2")
}
record (seq, "MGNT:COL1:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:COL1:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:COL1:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:COL1:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:COL1:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:COL1:120:ALLFUNCGO")
  field (LNK2, "QUAD:COL1:260:ALLFUNCGO")
  field (LNK3, "QUAD:COL1:280:ALLFUNCGO")
  field (LNK4, "QUAD:COL1:320:ALLFUNCGO")
  field (LNK5, "QUAD:COL1:400:ALLFUNCGO")
  field (LNK6, "QUAD:COL1:480:ALLFUNCGO")
  field (FLNK, "MGNT:COL1:1:QUADFUNCGO_2")
}
record (fanout, "MGNT:COL1:1:QUADFUNCGO_2"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:COL1:560:ALLFUNCGO")
  field (LNK2, "QUAD:COL1:640:ALLFUNCGO")
  field (LNK3, "QUAD:COL1:720:ALLFUNCGO")
  field (LNK4, "QUAD:COL1:800:ALLFUNCGO")
  field (LNK5, "QUAD:COL1:880:ALLFUNCGO")
  field (LNK6, "QUAD:COL1:960:ALLFUNCGO")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}

record (fanout, "MGNT:COL1:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:COL1:128:ALLFUNCGO")
  field (LNK2, "XCOR:COL1:328:ALLFUNCGO")
  field (LNK3, "XCOR:COL1:488:ALLFUNCGO")
  field (LNK4, "XCOR:COL1:648:ALLFUNCGO")
  field (LNK5, "XCOR:COL1:808:ALLFUNCGO")
  field (LNK6, "XCOR:COL1:968:ALLFUNCGO")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (fanout, "MGNT:COL1:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:COL1:129:ALLFUNCGO")
  field (LNK2, "YCOR:COL1:409:ALLFUNCGO")
  field (LNK3, "YCOR:COL1:569:ALLFUNCGO")
  field (LNK4, "YCOR:COL1:729:ALLFUNCGO")
  field (LNK5, "YCOR:COL1:889:ALLFUNCGO")
  field (FLNK, "MGNT:COL1:1:CTRLCLEAR")
}
record (seq, "MGNT:L2B:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:L2B:1:ALLKICKSSEL"){
}
record (seq, "MGNT:L2B:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:L2B:1:ALLBENDSSEL"){
}
record (seq, "MGNT:L2B:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:L2B:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:L2B:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L2B:1:ALLQUADS")
  field (DOL2, "MGNT:L2B:1:ALLQUADS")
  field (DOL3, "MGNT:L2B:1:ALLQUADS")
  field (DOL4, "MGNT:L2B:1:ALLQUADS")
  field (DOL5, "MGNT:L2B:1:ALLQUADS")
  field (DOL6, "MGNT:L2B:1:ALLQUADS")
  field (DOL7, "MGNT:L2B:1:ALLQUADS")
  field (DOL8, "MGNT:L2B:1:ALLQUADS")
  field (DOLA, "MGNT:L2B:1:ALLQUADS")
  field (LNK1, "QUAD:L2B:0485:SELECT PP NMS")
  field (LNK2, "QUAD:L2B:0585:SELECT PP NMS")
  field (LNK3, "QUAD:L2B:0685:SELECT PP NMS")
  field (LNK4, "QUAD:L2B:0785:SELECT PP NMS")
  field (LNK5, "QUAD:L2B:0885:SELECT PP NMS")
  field (LNK6, "QUAD:L2B:0985:SELECT PP NMS")
  field (LNK7, "QUAD:L2B:1085:SELECT PP NMS")
  field (LNK8, "QUAD:L2B:1185:SELECT PP NMS")
  field (LNKA, "QUAD:L2B:1285:SELECT PP NMS")
  field(FLNK, "MGNT:L2B:1:ALLQUADSSEL_2.PROC")
}
record (seq, "MGNT:L2B:1:ALLQUADSSEL_2"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L2B:1:ALLQUADS")
  field (DOL2, "MGNT:L2B:1:ALLQUADS")
  field (DOL3, "MGNT:L2B:1:ALLQUADS")
  field (LNK1, "QUAD:L2B:1385:SELECT PP NMS")
  field (LNK2, "QUAD:L2B:1485:SELECT PP NMS")
  field (LNK3, "QUAD:L2B:1585:SELECT PP NMS")

}

record (seq, "MGNT:L2B:1:ALLXCORSSEL"){
  field (DESC, "Select All XCORs")
  field (DOL1, "MGNT:L2B:1:ALLXCORS")
  field (DOL2, "MGNT:L2B:1:ALLXCORS")
  field (DOL3, "MGNT:L2B:1:ALLXCORS")
  field (DOL4, "MGNT:L2B:1:ALLXCORS")
  field (DOL5, "MGNT:L2B:1:ALLXCORS")
  field (DOL6, "MGNT:L2B:1:ALLXCORS")
  field (DOL7, "MGNT:L2B:1:ALLXCORS")
  field (DOL8, "MGNT:L2B:1:ALLXCORS")
  field (DOLA, "MGNT:L2B:1:ALLXCORS")
  field (LNK1, "XCOR:L2B:0485:SELECT PP NMS")
  field (LNK2, "XCOR:L2B:0585:SELECT PP NMS")
  field (LNK3, "XCOR:L2B:0685:SELECT PP NMS")
  field (LNK4, "XCOR:L2B:0785:SELECT PP NMS")
  field (LNK5, "XCOR:L2B:0885:SELECT PP NMS")
  field (LNK6, "XCOR:L2B:0985:SELECT PP NMS")
  field (LNK7, "XCOR:L2B:1085:SELECT PP NMS")
  field (LNK8, "XCOR:L2B:1185:SELECT PP NMS")
  field (LNKA, "XCOR:L2B:1285:SELECT PP NMS")
  field (FLNK, "MGNT:L2B:1:ALLXCORSSEL_2")
}
record (seq, "MGNT:L2B:1:ALLXCORSSEL_2"){
  field (DESC, "Select All XCORs")
  field (DOL1, "MGNT:L2B:1:ALLXCORS")
  field (DOL2, "MGNT:L2B:1:ALLXCORS")
  field (DOL3, "MGNT:L2B:1:ALLXCORS")
  field (LNK1, "XCOR:L2B:1385:SELECT PP NMS")
  field (LNK2, "XCOR:L2B:1485:SELECT PP NMS")
  field (LNK3, "XCOR:L2B:1585:SELECT PP NMS")
}

record (seq, "MGNT:L2B:1:ALLYCORSSEL"){
  field (DESC, "Select All YCORs")
  field (DOL1, "MGNT:L2B:1:ALLYCORS")
  field (DOL2, "MGNT:L2B:1:ALLYCORS")
  field (DOL3, "MGNT:L2B:1:ALLYCORS")
  field (DOL4, "MGNT:L2B:1:ALLYCORS")
  field (DOL5, "MGNT:L2B:1:ALLYCORS")
  field (DOL6, "MGNT:L2B:1:ALLYCORS")
  field (DOL7, "MGNT:L2B:1:ALLYCORS")
  field (DOL8, "MGNT:L2B:1:ALLYCORS")
  field (DOLA, "MGNT:L2B:1:ALLYCORS")
  field (LNK1, "YCOR:L2B:0485:SELECT PP NMS")
  field (LNK2, "YCOR:L2B:0585:SELECT PP NMS")
  field (LNK3, "YCOR:L2B:0685:SELECT PP NMS")
  field (LNK4, "YCOR:L2B:0785:SELECT PP NMS")
  field (LNK5, "YCOR:L2B:0885:SELECT PP NMS")
  field (LNK6, "YCOR:L2B:0985:SELECT PP NMS")
  field (LNK7, "YCOR:L2B:1085:SELECT PP NMS")
  field (LNK8, "YCOR:L2B:1185:SELECT PP NMS")
  field (LNKA, "YCOR:L2B:1285:SELECT PP NMS")
  field(FLNK, "MGNT:L2B:1:ALLYCORSSEL_2.PROC")
}
record (seq, "MGNT:L2B:1:ALLYCORSSEL_2"){
  field (DESC, "Select All YCORs")
  field (DOL1, "MGNT:L2B:1:ALLYCORS")
  field (DOL2, "MGNT:L2B:1:ALLYCORS")
  field (DOL3, "MGNT:L2B:1:ALLYCORS")
  field (LNK1, "YCOR:L2B:1385:SELECT PP NMS")
  field (LNK2, "YCOR:L2B:1485:SELECT PP NMS")
  field (LNK3, "YCOR:L2B:1585:SELECT PP NMS")

}

record (seq, "MGNT:L2B:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:L2B:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:L2B:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:L2B:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:L2B:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:L2B:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:L2B:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:L2B:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:L2B:1:ALLFUNCGO2")
}
record (seq, "MGNT:L2B:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:L2B:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:L2B:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:L2B:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:L2B:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L2B:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:L2B:0485:ALLFUNCGO")
  field (LNK2, "QUAD:L2B:0585:ALLFUNCGO")
  field (LNK3, "QUAD:L2B:0685:ALLFUNCGO")
  field (LNK4, "QUAD:L2B:0785:ALLFUNCGO")
  field (LNK5, "QUAD:L2B:0885:ALLFUNCGO")
  field (LNK6, "QUAD:L2B:0985:ALLFUNCGO")
  field (FLNK, "MGNT:L2B:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:L2B:1:QUADFUNCGO_2") {
  field (LNK1, "QUAD:L2B:1085:ALLFUNCGO")
  field (LNK2, "QUAD:L2B:1185:ALLFUNCGO")
  field (LNK3, "QUAD:L2B:1285:ALLFUNCGO")
  field (LNK4, "QUAD:L2B:1385:ALLFUNCGO")
  field (LNK5, "QUAD:L2B:1485:ALLFUNCGO")
  field (LNK6, "QUAD:L2B:1585:ALLFUNCGO")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}

record (fanout, "MGNT:L2B:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:L2B:0485:ALLFUNCGO")
  field (LNK2, "XCOR:L2B:0585:ALLFUNCGO")
  field (LNK3, "XCOR:L2B:0685:ALLFUNCGO")
  field (LNK4, "XCOR:L2B:0785:ALLFUNCGO")
  field (LNK5, "XCOR:L2B:0885:ALLFUNCGO")
  field (LNK6, "XCOR:L2B:0985:ALLFUNCGO")
  field (FLNK, "MGNT:L2B:1:XCORFUNCGO_2")
}
record(fanout, "MGNT:L2B:1:XCORFUNCGO_2") {
  field (LNK1, "XCOR:L2B:1085:ALLFUNCGO")
  field (LNK2, "XCOR:L2B:1185:ALLFUNCGO")
  field (LNK3, "XCOR:L2B:1285:ALLFUNCGO")
  field (LNK4, "XCOR:L2B:1385:ALLFUNCGO")
  field (LNK5, "XCOR:L2B:1485:ALLFUNCGO")
  field (LNK6, "XCOR:L2B:1585:ALLFUNCGO")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}

record (fanout, "MGNT:L2B:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:L2B:0485:ALLFUNCGO")
  field (LNK2, "YCOR:L2B:0585:ALLFUNCGO")
  field (LNK3, "YCOR:L2B:0685:ALLFUNCGO")
  field (LNK4, "YCOR:L2B:0785:ALLFUNCGO")
  field (LNK5, "YCOR:L2B:0885:ALLFUNCGO")
  field (LNK6, "YCOR:L2B:0985:ALLFUNCGO")
  field (FLNK, "MGNT:L2B:1:YCORFUNCGO_2")
}
record(fanout, "MGNT:L2B:1:YCORFUNCGO_2") {
  field (LNK1, "YCOR:L2B:1085:ALLFUNCGO")
  field (LNK2, "YCOR:L2B:1185:ALLFUNCGO")
  field (LNK3, "YCOR:L2B:1285:ALLFUNCGO")
  field (LNK4, "YCOR:L2B:1385:ALLFUNCGO")
  field (LNK5, "YCOR:L2B:1485:ALLFUNCGO")
  field (LNK6, "YCOR:L2B:1585:ALLFUNCGO")
  field (FLNK, "MGNT:L2B:1:CTRLCLEAR")
}

record (seq, "MGNT:L3B:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:L3B:1:ALLKICKSSEL"){
}
record (seq, "MGNT:L3B:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:L3B:1:ALLBENDSSEL"){
}
record (seq, "MGNT:L3B:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:L3B:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:L3B:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L3B:1:ALLQUADS")
  field (DOL2, "MGNT:L3B:1:ALLQUADS")
  field (DOL3, "MGNT:L3B:1:ALLQUADS")
  field (DOL4, "MGNT:L3B:1:ALLQUADS")
  field (DOL5, "MGNT:L3B:1:ALLQUADS")
  field (DOL6, "MGNT:L3B:1:ALLQUADS")
  field (DOL7, "MGNT:L3B:1:ALLQUADS")
  field (DOL8, "MGNT:L3B:1:ALLQUADS")
  field (DOLA, "MGNT:L3B:1:ALLQUADS")
  field (LNK1, "QUAD:L3B:1685:SELECT PP NMS")
  field (LNK2, "QUAD:L3B:1785:SELECT PP NMS")
  field (LNK3, "QUAD:L3B:1885:SELECT PP NMS")
  field (LNK4, "QUAD:L3B:1985:SELECT PP NMS")
  field (LNK5, "QUAD:L3B:2085:SELECT PP NMS")
  field (LNK6, "QUAD:L3B:2185:SELECT PP NMS")
  field (LNK7, "QUAD:L3B:2285:SELECT PP NMS")
  field (LNK8, "QUAD:L3B:2385:SELECT PP NMS")
  field (LNKA, "QUAD:L3B:2485:SELECT PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLQUADSSEL_2.PROC")
}
record (seq, "MGNT:L3B:1:ALLQUADSSEL_2"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L3B:1:ALLQUADS")
  field (DOL2, "MGNT:L3B:1:ALLQUADS")
  field (DOL3, "MGNT:L3B:1:ALLQUADS")
  field (DOL4, "MGNT:L3B:1:ALLQUADS")
  field (DOL5, "MGNT:L3B:1:ALLQUADS")
  field (DOL6, "MGNT:L3B:1:ALLQUADS")
  field (DOL7, "MGNT:L3B:1:ALLQUADS")
  field (DOL8, "MGNT:L3B:1:ALLQUADS")
  field (DOLA, "MGNT:L3B:1:ALLQUADS")
  field (LNK1, "QUAD:L3B:2585:SELECT PP NMS")
  field (LNK2, "QUAD:L3B:2685:SELECT PP NMS")
  field (LNK3, "QUAD:L3B:2785:SELECT PP NMS")
  field (LNK4, "QUAD:L3B:2885:SELECT PP NMS")
  field (LNK5, "QUAD:L3B:2985:SELECT PP NMS")
  field (LNK6, "QUAD:L3B:3085:SELECT PP NMS")
  field (LNK7, "QUAD:L3B:3185:SELECT PP NMS")
  field (LNK8, "QUAD:L3B:3285:SELECT PP NMS")
  field (LNKA, "QUAD:L3B:3385:SELECT PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLQUADSSEL_3.PROC")
}
record (seq, "MGNT:L3B:1:ALLQUADSSEL_3"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:L3B:1:ALLQUADS")
  field (DOL2, "MGNT:L3B:1:ALLQUADS")
  field (LNK1, "QUAD:L3B:3485:SELECT PP NMS")
  field (LNK2, "QUAD:L3B:3585:SELECT PP NMS")
}

record (seq, "MGNT:L3B:1:ALLXCORSSEL"){
  field (DESC, "Select All XCORs")
  field (DOL1, "MGNT:L3B:1:ALLXCORS")
  field (DOL2, "MGNT:L3B:1:ALLXCORS")
  field (DOL3, "MGNT:L3B:1:ALLXCORS")
  field (DOL4, "MGNT:L3B:1:ALLXCORS")
  field (DOL5, "MGNT:L3B:1:ALLXCORS")
  field (DOL6, "MGNT:L3B:1:ALLXCORS")
  field (DOL7, "MGNT:L3B:1:ALLXCORS")
  field (DOL8, "MGNT:L3B:1:ALLXCORS")
  field (DOLA, "MGNT:L3B:1:ALLXCORS")
  field (LNK1, "XCOR:L3B:1685:SELECT PP NMS")
  field (LNK2, "XCOR:L3B:1785:SELECT PP NMS")
  field (LNK3, "XCOR:L3B:1885:SELECT PP NMS")
  field (LNK4, "XCOR:L3B:1985:SELECT PP NMS")
  field (LNK5, "XCOR:L3B:2085:SELECT PP NMS")
  field (LNK6, "XCOR:L3B:2185:SELECT PP NMS")
  field (LNK7, "XCOR:L3B:2285:SELECT PP NMS")
  field (LNK8, "XCOR:L3B:2385:SELECT PP NMS")
  field (LNKA, "XCOR:L3B:2485:SELECT PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLXCORSSEL_2.PROC")
}
record (seq, "MGNT:L3B:1:ALLXCORSSEL_2"){
  field (DESC, "Select All XCORs")
  field (DOL1, "MGNT:L3B:1:ALLXCORS")
  field (DOL2, "MGNT:L3B:1:ALLXCORS")
  field (DOL3, "MGNT:L3B:1:ALLXCORS")
  field (DOL4, "MGNT:L3B:1:ALLXCORS")
  field (DOL5, "MGNT:L3B:1:ALLXCORS")
  field (DOL6, "MGNT:L3B:1:ALLXCORS")
  field (DOL7, "MGNT:L3B:1:ALLXCORS")
  field (DOL8, "MGNT:L3B:1:ALLXCORS")
  field (DOLA, "MGNT:L3B:1:ALLXCORS")
  field (LNK1, "XCOR:L3B:2585:SELECT PP NMS")
  field (LNK2, "XCOR:L3B:2685:SELECT PP NMS")
  field (LNK3, "XCOR:L3B:2785:SELECT PP NMS")
  field (LNK4, "XCOR:L3B:2885:SELECT PP NMS")
  field (LNK5, "XCOR:L3B:2985:SELECT PP NMS")
  field (LNK6, "XCOR:L3B:3085:SELECT PP NMS")
  field (LNK7, "XCOR:L3B:3185:SELECT PP NMS")
  field (LNK8, "XCOR:L3B:3285:SELECT PP NMS")
  field (LNKA, "XCOR:L3B:3385:SELECT PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLXCORSSEL_3.PROC")
}
record (seq, "MGNT:L3B:1:ALLXCORSSEL_3"){
  field (DESC, "Select All XCORs")
  field (DOL1, "MGNT:L3B:1:ALLXCORS")
  field (DOL2, "MGNT:L3B:1:ALLXCORS")
  field (LNK1, "XCOR:L3B:3485:SELECT PP NMS")
  field (LNK2, "XCOR:L3B:3585:SELECT PP NMS")
}

record (seq, "MGNT:L3B:1:ALLYCORSSEL"){
  field (DESC, "Select All YCORs")
  field (DOL1, "MGNT:L3B:1:ALLYCORS")
  field (DOL2, "MGNT:L3B:1:ALLYCORS")
  field (DOL3, "MGNT:L3B:1:ALLYCORS")
  field (DOL4, "MGNT:L3B:1:ALLYCORS")
  field (DOL5, "MGNT:L3B:1:ALLYCORS")
  field (DOL6, "MGNT:L3B:1:ALLYCORS")
  field (DOL7, "MGNT:L3B:1:ALLYCORS")
  field (DOL8, "MGNT:L3B:1:ALLYCORS")
  field (DOLA, "MGNT:L3B:1:ALLYCORS")
  field (LNK1, "YCOR:L3B:1685:SELECT PP NMS")
  field (LNK2, "YCOR:L3B:1785:SELECT PP NMS")
  field (LNK3, "YCOR:L3B:1885:SELECT PP NMS")
  field (LNK4, "YCOR:L3B:1985:SELECT PP NMS")
  field (LNK5, "YCOR:L3B:2085:SELECT PP NMS")
  field (LNK6, "YCOR:L3B:2185:SELECT PP NMS")
  field (LNK7, "YCOR:L3B:2285:SELECT PP NMS")
  field (LNK8, "YCOR:L3B:2385:SELECT PP NMS")
  field (LNKA, "YCOR:L3B:2485:SELECT PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLYCORSSEL_2.PROC")
}
record (seq, "MGNT:L3B:1:ALLYCORSSEL_2"){
  field (DESC, "Select All YCORs")
  field (DOL1, "MGNT:L3B:1:ALLYCORS")
  field (DOL2, "MGNT:L3B:1:ALLYCORS")
  field (DOL3, "MGNT:L3B:1:ALLYCORS")
  field (DOL4, "MGNT:L3B:1:ALLYCORS")
  field (DOL5, "MGNT:L3B:1:ALLYCORS")
  field (DOL6, "MGNT:L3B:1:ALLYCORS")
  field (DOL7, "MGNT:L3B:1:ALLYCORS")
  field (DOL8, "MGNT:L3B:1:ALLYCORS")
  field (DOLA, "MGNT:L3B:1:ALLYCORS")
  field (LNK1, "YCOR:L3B:2585:SELECT PP NMS")
  field (LNK2, "YCOR:L3B:2685:SELECT PP NMS")
  field (LNK3, "YCOR:L3B:2785:SELECT PP NMS")
  field (LNK4, "YCOR:L3B:2885:SELECT PP NMS")
  field (LNK5, "YCOR:L3B:2985:SELECT PP NMS")
  field (LNK6, "YCOR:L3B:3085:SELECT PP NMS")
  field (LNK7, "YCOR:L3B:3185:SELECT PP NMS")
  field (LNK8, "YCOR:L3B:3285:SELECT PP NMS")
  field (LNKA, "YCOR:L3B:3385:SELECT PP NMS")
  field(FLNK, "MGNT:L3B:1:ALLYCORSSEL_3.PROC")
}
record (seq, "MGNT:L3B:1:ALLYCORSSEL_3"){
  field (DESC, "Select All YCORs")
  field (DOL1, "MGNT:L3B:1:ALLYCORS")
  field (DOL2, "MGNT:L3B:1:ALLYCORS")
  field (LNK1, "YCOR:L3B:3485:SELECT PP NMS")
  field (LNK2, "YCOR:L3B:3585:SELECT PP NMS")
}


record (seq, "MGNT:L3B:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:L3B:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:L3B:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:L3B:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:L3B:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:L3B:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:L3B:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:L3B:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:L3B:1:ALLFUNCGO2")
}
record (seq, "MGNT:L3B:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:L3B:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:L3B:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:L3B:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:L3B:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}
record (fanout, "MGNT:L3B:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:L3B:1685:ALLFUNCGO")
  field (LNK2, "QUAD:L3B:1785:ALLFUNCGO")
  field (LNK3, "QUAD:L3B:1885:ALLFUNCGO")
  field (LNK4, "QUAD:L3B:1985:ALLFUNCGO")
  field (LNK5, "QUAD:L3B:2085:ALLFUNCGO")
  field (LNK6, "QUAD:L3B:2185:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:L3B:1:QUADFUNCGO_2") {
  field (LNK1, "QUAD:L3B:2285:ALLFUNCGO")
  field (LNK2, "QUAD:L3B:2385:ALLFUNCGO")
  field (LNK3, "QUAD:L3B:2485:ALLFUNCGO")
  field (LNK4, "QUAD:L3B:2585:ALLFUNCGO")
  field (LNK5, "QUAD:L3B:2685:ALLFUNCGO")
  field (LNK6, "QUAD:L3B:2785:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:QUADFUNCGO_3")
}
record(fanout, "MGNT:L3B:1:QUADFUNCGO_3") {
  field (LNK1, "QUAD:L3B:2885:ALLFUNCGO")
  field (LNK2, "QUAD:L3B:2985:ALLFUNCGO")
  field (LNK3, "QUAD:L3B:3085:ALLFUNCGO")
  field (LNK4, "QUAD:L3B:3185:ALLFUNCGO")
  field (LNK5, "QUAD:L3B:3285:ALLFUNCGO")
  field (LNK6, "QUAD:L3B:3385:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:QUADFUNCGO_4")
}
record(fanout, "MGNT:L3B:1:QUADFUNCGO_4") {
  field (LNK1, "QUAD:L3B:3485:ALLFUNCGO")
  field (LNK2, "QUAD:L3B:3585:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}

record (fanout, "MGNT:L3B:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:L3B:1685:ALLFUNCGO")
  field (LNK2, "XCOR:L3B:1785:ALLFUNCGO")
  field (LNK3, "XCOR:L3B:1885:ALLFUNCGO")
  field (LNK4, "XCOR:L3B:1985:ALLFUNCGO")
  field (LNK5, "XCOR:L3B:2085:ALLFUNCGO")
  field (LNK6, "XCOR:L3B:2185:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:XCORFUNCGO_2")
}
record(fanout, "MGNT:L3B:1:XCORFUNCGO_2") {
  field (LNK1, "XCOR:L3B:2285:ALLFUNCGO")
  field (LNK2, "XCOR:L3B:2385:ALLFUNCGO")
  field (LNK3, "XCOR:L3B:2485:ALLFUNCGO")
  field (LNK4, "XCOR:L3B:2585:ALLFUNCGO")
  field (LNK5, "XCOR:L3B:2685:ALLFUNCGO")
  field (LNK6, "XCOR:L3B:2785:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:XCORFUNCGO_3")
}
record(fanout, "MGNT:L3B:1:XCORFUNCGO_3") {
  field (LNK1, "XCOR:L3B:2885:ALLFUNCGO")
  field (LNK2, "XCOR:L3B:2985:ALLFUNCGO")
  field (LNK3, "XCOR:L3B:3085:ALLFUNCGO")
  field (LNK4, "XCOR:L3B:3185:ALLFUNCGO")
  field (LNK5, "XCOR:L3B:3285:ALLFUNCGO")
  field (LNK6, "XCOR:L3B:3385:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:XCORFUNCGO_4")
}
record(fanout, "MGNT:L3B:1:XCORFUNCGO_4") {
  field (LNK1, "XCOR:L3B:3485:ALLFUNCGO")
  field (LNK2, "XCOR:L3B:3585:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}

record (fanout, "MGNT:L3B:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:L3B:1685:ALLFUNCGO")
  field (LNK2, "YCOR:L3B:1785:ALLFUNCGO")
  field (LNK3, "YCOR:L3B:1885:ALLFUNCGO")
  field (LNK4, "YCOR:L3B:1985:ALLFUNCGO")
  field (LNK5, "YCOR:L3B:2085:ALLFUNCGO")
  field (LNK6, "YCOR:L3B:2185:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:YCORFUNCGO_2")
}
record(fanout, "MGNT:L3B:1:YCORFUNCGO_2") {
  field (LNK1, "YCOR:L3B:2285:ALLFUNCGO")
  field (LNK2, "YCOR:L3B:2385:ALLFUNCGO")
  field (LNK3, "YCOR:L3B:2485:ALLFUNCGO")
  field (LNK4, "YCOR:L3B:2585:ALLFUNCGO")
  field (LNK5, "YCOR:L3B:2685:ALLFUNCGO")
  field (LNK6, "YCOR:L3B:2785:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:YCORFUNCGO_3")
}
record(fanout, "MGNT:L3B:1:YCORFUNCGO_3") {
  field (LNK1, "YCOR:L3B:2885:ALLFUNCGO")
  field (LNK2, "YCOR:L3B:2985:ALLFUNCGO")
  field (LNK3, "YCOR:L3B:3085:ALLFUNCGO")
  field (LNK4, "YCOR:L3B:3185:ALLFUNCGO")
  field (LNK5, "YCOR:L3B:3285:ALLFUNCGO")
  field (LNK6, "YCOR:L3B:3385:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:YCORFUNCGO_4")
}
record(fanout, "MGNT:L3B:1:YCORFUNCGO_4") {
  field (LNK1, "YCOR:L3B:3485:ALLFUNCGO")
  field (LNK2, "YCOR:L3B:3585:ALLFUNCGO")
  field (FLNK, "MGNT:L3B:1:CTRLCLEAR")
}

record (seq, "MGNT:EXT:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:EXT:1:ALLKICKSSEL"){
}
record (seq, "MGNT:EXT:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:EXT:1:ALLBENDSSEL"){
}
record (seq, "MGNT:EXT:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:EXT:1:ALLLGPSSSEL"){
  field (DOL1, "MGNT:EXT:1:ALLLGPSS")
  field (DOL2, "MGNT:EXT:1:ALLLGPSS")
  field (LNK1, "LGPS:EXT:1:SELECT PP NMS")
  field (LNK2, "LGPS:EXT:2:SELECT PP NMS")

}
record (seq, "MGNT:EXT:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:EXT:1:ALLQUADS")
  field (DOL2, "MGNT:EXT:1:ALLQUADS")
  field (LNK1, "QUAD:EXT:351:SELECT PP NMS")
  field (LNK2, "QUAD:EXT:748:SELECT PP NMS")
}
record (seq, "MGNT:EXT:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:EXT:1:ALLXCORS")
  field (LNK1, "XCOR:EXT:368:SELECT PP NMS")
}
record (seq, "MGNT:EXT:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:EXT:1:ALLYCORS")
  field (LNK1, "YCOR:EXT:762:SELECT PP NMS")
}
record (seq, "MGNT:EXT:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:EXT:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:EXT:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:EXT:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:EXT:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:EXT:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:EXT:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:EXT:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:EXT:1:ALLFUNCGO2")
}
record (seq, "MGNT:EXT:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:EXT:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:EXT:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:EXT:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:EXT:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (LNK1, "LGPS:EXT:1:ALLFUNCGO")
  field (LNK2, "LGPS:EXT:2:ALLFUNCGO")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:EXT:351:ALLFUNCGO")
  field (LNK2, "QUAD:EXT:748:ALLFUNCGO")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:EXT:368:ALLFUNCGO")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (fanout, "MGNT:EXT:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:EXT:762:ALLFUNCGO")
  field (FLNK, "MGNT:EXT:1:CTRLCLEAR")
}
record (seq, "MGNT:EMIT2:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:EMIT2:1:ALLKICKSSEL"){
}
record (seq, "MGNT:EMIT2:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:EMIT2:1:ALLBENDSSEL"){
}
record (seq, "MGNT:EMIT2:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:EMIT2:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:EMIT2:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:EMIT2:1:ALLQUADS")
  field (DOL2, "MGNT:EMIT2:1:ALLQUADS")
  field (DOL3, "MGNT:EMIT2:1:ALLQUADS")
  field (DOL4, "MGNT:EMIT2:1:ALLQUADS")
  field (LNK1, "QUAD:EMIT2:150:SELECT PP NMS")
  field (LNK2, "QUAD:EMIT2:300:SELECT PP NMS")
  field (LNK3, "QUAD:EMIT2:800:SELECT PP NMS")
  field (LNK4, "QUAD:EMIT2:900:SELECT PP NMS")
}
record (seq, "MGNT:EMIT2:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:EMIT2:1:ALLXCORS")
  field (DOL2, "MGNT:EMIT2:1:ALLXCORS")
  field (LNK1, "XCOR:EMIT2:310:SELECT PP NMS")
  field (LNK2, "XCOR:EMIT2:912:SELECT PP NMS")
}
record (seq, "MGNT:EMIT2:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:EMIT2:1:ALLYCORS")
  field (DOL2, "MGNT:EMIT2:1:ALLYCORS")
  field (LNK1, "YCOR:EMIT2:161:SELECT PP NMS")
  field (LNK2, "YCOR:EMIT2:811:SELECT PP NMS")
}
record (seq, "MGNT:EMIT2:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:EMIT2:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:EMIT2:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:EMIT2:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:EMIT2:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:EMIT2:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:EMIT2:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:EMIT2:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:EMIT2:1:ALLFUNCGO2")
}
record (seq, "MGNT:EMIT2:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:EMIT2:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:EMIT2:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:EMIT2:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:EMIT2:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:EMIT2:150:ALLFUNCGO")
  field (LNK2, "QUAD:EMIT2:300:ALLFUNCGO")
  field (LNK3, "QUAD:EMIT2:800:ALLFUNCGO")
  field (LNK4, "QUAD:EMIT2:900:ALLFUNCGO")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}

record (fanout, "MGNT:EMIT2:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:EMIT2:310:ALLFUNCGO")
  field (LNK2, "XCOR:EMIT2:912:ALLFUNCGO")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (fanout, "MGNT:EMIT2:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:EMIT2:161:ALLFUNCGO")
  field (LNK2, "YCOR:EMIT2:811:ALLFUNCGO")
  field (FLNK, "MGNT:EMIT2:1:CTRLCLEAR")
}
record (seq, "MGNT:DOG:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:DOG:1:ALLKICKSSEL"){
}
record (seq, "MGNT:DOG:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:DOG:1:ALLBENDSSEL"){
  field (DESC, "Select All BENDs")
  field (DOL1, "MGNT:DOG:1:ALLBENDS")
  field (DOL2, "MGNT:DOG:1:ALLBENDS")
  field (DOL3, "MGNT:DOG:1:ALLBENDS")
  field (LNK1, "BEND:DOG:106:SELECT PP NMS")
  field (LNK2, "BEND:DOG:240:SELECT PP NMS")
  field (LNK3, "BEND:DOG:242:SELECT PP NMS")
}
record (seq, "MGNT:DOG:1:ALLBTRMSSEL"){
  field (DESC, "Select All BTRMs")
  field (DOL1, "MGNT:DOG:1:ALLBTRMS")
  field (DOL2, "MGNT:DOG:1:ALLBTRMS")
  field (DOL3, "MGNT:DOG:1:ALLBTRMS")
  field (DOL4, "MGNT:DOG:1:ALLBTRMS")
  field (DOL5, "MGNT:DOG:1:ALLBTRMS")
  field (DOL6, "MGNT:DOG:1:ALLBTRMS")
  field (DOL7, "MGNT:DOG:1:ALLBTRMS")
  field (LNK1, "BTRM:DOG:105:SELECT PP NMS")
  field (LNK2, "BTRM:DOG:107:SELECT PP NMS")
  field (LNK3, "BTRM:DOG:108:SELECT PP NMS")
  field (LNK4, "BTRM:DOG:110:SELECT PP NMS")
  field (LNK5, "BTRM:DOG:241:SELECT PP NMS")
  field (LNK6, "BTRM:DOG:243:SELECT PP NMS")
  field (LNK7, "BTRM:DOG:244:SELECT PP NMS")
}
record (seq, "MGNT:DOG:1:ALLLGPSSSEL"){
}
record (seq, "MGNT:DOG:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:DOG:1:ALLQUADS")
  field (DOL2, "MGNT:DOG:1:ALLQUADS")
  field (DOL3, "MGNT:DOG:1:ALLQUADS")
  field (DOL4, "MGNT:DOG:1:ALLQUADS")
  field (DOL5, "MGNT:DOG:1:ALLQUADS")
  field (DOL6, "MGNT:DOG:1:ALLQUADS")
  field (DOL7, "MGNT:DOG:1:ALLQUADS")
  field (DOL8, "MGNT:DOG:1:ALLQUADS")
  field (DOL9, "MGNT:DOG:1:ALLQUADS")
  field (DOLA, "MGNT:DOG:1:ALLQUADS")
  field (LNK1, "QUAD:DOG:120:SELECT PP NMS")
  field (LNK2, "QUAD:DOG:135:SELECT PP NMS")
  field (LNK3, "QUAD:DOG:150:SELECT PP NMS")
  field (LNK4, "QUAD:DOG:165:SELECT PP NMS")
  field (LNK5, "QUAD:DOG:250:SELECT PP NMS")
  field (LNK6, "QUAD:DOG:280:SELECT PP NMS")
  field (LNK7, "QUAD:DOG:335:SELECT PP NMS")
  field (LNK8, "QUAD:DOG:355:SELECT PP NMS")
  field (LNK9, "QUAD:DOG:405:SELECT PP NMS")
  field (LNKA, "QUAD:DOG:575:SELECT PP NMS")
}
record (seq, "MGNT:DOG:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:DOG:1:ALLXCORS")
  field (DOL2, "MGNT:DOG:1:ALLXCORS")
  field (DOL3, "MGNT:DOG:1:ALLXCORS")
  field (DOL4, "MGNT:DOG:1:ALLXCORS")
  field (DOL5, "MGNT:DOG:1:ALLXCORS")
  field (DOL6, "MGNT:DOG:1:ALLXCORS")
  field (DOL7, "MGNT:DOG:1:ALLXCORS")
  field (DOL8, "MGNT:DOG:1:ALLXCORS")
  field (DOL9, "MGNT:DOG:1:ALLXCORS")
  field (LNK1, "XCOR:DOG:116:SELECT PP NMS")
  field (LNK2, "XCOR:DOG:148:SELECT PP NMS")
  field (LNK3, "XCOR:DOG:178:SELECT PP NMS")
  field (LNK4, "XCOR:DOG:212:SELECT PP NMS")
  field (LNK5, "XCOR:DOG:252:SELECT PP NMS")
  field (LNK6, "XCOR:DOG:338:SELECT PP NMS")
  field (LNK7, "XCOR:DOG:408:SELECT PP NMS")
  field (LNK8, "XCOR:DOG:584:SELECT PP NMS")
  field (LNK9, "XCOR:DOG:744:SELECT PP NMS")
}
record (seq, "MGNT:DOG:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:DOG:1:ALLYCORS")
  field (DOL2, "MGNT:DOG:1:ALLYCORS")
  field (DOL3, "MGNT:DOG:1:ALLYCORS")
  field (DOL4, "MGNT:DOG:1:ALLYCORS")
  field (DOL5, "MGNT:DOG:1:ALLYCORS")
  field (DOL6, "MGNT:DOG:1:ALLYCORS")
  field (DOL7, "MGNT:DOG:1:ALLYCORS")
  field (DOL8, "MGNT:DOG:1:ALLYCORS")
  field (DOL9, "MGNT:DOG:1:ALLYCORS")
  field (LNK1, "YCOR:DOG:113:SELECT PP NMS")
  field (LNK2, "YCOR:DOG:137:SELECT PP NMS")
  field (LNK3, "YCOR:DOG:163:SELECT PP NMS")
  field (LNK4, "YCOR:DOG:193:SELECT PP NMS")
  field (LNK5, "YCOR:DOG:227:SELECT PP NMS")
  field (LNK6, "YCOR:DOG:281:SELECT PP NMS")
  field (LNK7, "YCOR:DOG:357:SELECT PP NMS")
  field (LNK8, "YCOR:DOG:577:SELECT PP NMS")
  field (LNK9, "YCOR:DOG:911:SELECT PP NMS")
}
record (seq, "MGNT:DOG:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")
  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:DOG:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:DOG:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:DOG:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:DOG:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:DOG:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:DOG:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:DOG:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:DOG:1:ALLFUNCGO_2")
}
record (seq, "MGNT:DOG:1:ALLFUNCGO_2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:DOG:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:DOG:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:DOG:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:DOG:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (LNK1, "BEND:DOG:106:ALLFUNCGO")
  field (LNK2, "BEND:DOG:240:ALLFUNCGO")
  field (LNK3, "BEND:DOG:242:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:DOG:105:ALLFUNCGO")
  field (LNK2, "BTRM:DOG:107:ALLFUNCGO")
  field (LNK3, "BTRM:DOG:108:ALLFUNCGO")
  field (LNK4, "BTRM:DOG:110:ALLFUNCGO")
  field (LNK5, "BTRM:DOG:241:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:BTRMFUNCGO_2")
}
record (fanout, "MGNT:DOG:1:BTRMFUNCGO_2"){
  field (DESC, "Process All BTRMs")
  field (LNK1, "BTRM:DOG:243:ALLFUNCGO")
  field (LNK2, "BTRM:DOG:244:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:DOG:120:ALLFUNCGO")
  field (LNK2, "QUAD:DOG:135:ALLFUNCGO")
  field (LNK3, "QUAD:DOG:150:ALLFUNCGO")
  field (LNK4, "QUAD:DOG:165:ALLFUNCGO")
  field (LNK5, "QUAD:DOG:250:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:QUADFUNCGO_2")
}
record (fanout, "MGNT:DOG:1:QUADFUNCGO_2"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:DOG:280:ALLFUNCGO")
  field (LNK2, "QUAD:DOG:335:ALLFUNCGO")
  field (LNK3, "QUAD:DOG:355:ALLFUNCGO")
  field (LNK4, "QUAD:DOG:405:ALLFUNCGO")
  field (LNK5, "QUAD:DOG:575:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:DOG:116:ALLFUNCGO")
  field (LNK2, "XCOR:DOG:148:ALLFUNCGO")
  field (LNK3, "XCOR:DOG:178:ALLFUNCGO")
  field (LNK4, "XCOR:DOG:212:ALLFUNCGO")
  field (LNK5, "XCOR:DOG:252:ALLFUNCGO")
  field (LNK6, "XCOR:DOG:338:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:XCORFUNCGO_2")
}
record (fanout, "MGNT:DOG:1:XCORFUNCGO_2"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:DOG:408:ALLFUNCGO")
  field (LNK2, "XCOR:DOG:584:ALLFUNCGO")
  field (LNK3, "XCOR:DOG:744:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (fanout, "MGNT:DOG:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:DOG:113:ALLFUNCGO")
  field (LNK2, "YCOR:DOG:137:ALLFUNCGO")
  field (LNK3, "YCOR:DOG:163:ALLFUNCGO")
  field (LNK4, "YCOR:DOG:193:ALLFUNCGO")
  field (LNK5, "YCOR:DOG:227:ALLFUNCGO")
  field (LNK6, "YCOR:DOG:281:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:YCORFUNCGO_2")
}
record (fanout, "MGNT:DOG:1:YCORFUNCGO_2"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:DOG:357:ALLFUNCGO")
  field (LNK2, "YCOR:DOG:577:ALLFUNCGO")
  field (LNK3, "YCOR:DOG:911:ALLFUNCGO")
  field (FLNK, "MGNT:DOG:1:CTRLCLEAR")
}
record (seq, "MGNT:BYP:1:ALLSOLNSSEL"){
}
record (seq, "MGNT:BYP:1:ALLKICKSSEL"){
}
record (seq, "MGNT:BYP:1:ALLSEXTSSEL"){
}
record (seq, "MGNT:BYP:1:ALLBENDSSEL"){
}
record (seq, "MGNT:BYP:1:ALLBTRMSSEL"){
}
record (seq, "MGNT:BYP:1:ALLLGPSSSEL"){
  field (DESC, "Select All LGPSs")
  field (DOL1, "MGNT:BYP:1:ALLLGPSS")
  field (DOL2, "MGNT:BYP:1:ALLLGPSS")
  field (DOL3, "MGNT:BYP:1:ALLLGPSS")
  field (DOL4, "MGNT:BYP:1:ALLLGPSS")
  field (DOL5, "MGNT:BYP:1:ALLLGPSS")
  field (LNK1, "LGPS:BPN10:1:SELECT PP NMS")
  field (LNK2, "LGPS:BPN17:1:SELECT PP NMS")
  field (LNK3, "LGPS:BPN21:1:SELECT PP NMS")
  field (LNK4, "LGPS:BPN21:1:SELECT PP NMS")
  field (LNK5, "LGPS:BPN25:1:SELECT PP NMS")
}
record (seq, "MGNT:BYP:1:ALLQUADSSEL"){
  field (DESC, "Select All QUADs")
  field (DOL1, "MGNT:BYP:1:ALLQUADS")
  field (DOL2, "MGNT:BYP:1:ALLQUADS")
  field (DOL3, "MGNT:BYP:1:ALLQUADS")
  field (DOL4, "MGNT:BYP:1:ALLQUADS")
  field (DOL5, "MGNT:BYP:1:ALLQUADS")
  field (DOL6, "MGNT:BYP:1:ALLQUADS")
  field (LNK1, "QUAD:DOG:575:SELECT PP NMS")
  field (LNK2, "QUAD:BPN25:400:SELECT PP NMS")
  field (LNK3, "QUAD:BPN26:400:SELECT PP NMS")
  field (LNK4, "QUAD:BPN27:400:SELECT PP NMS")
  field (LNK5, "QUAD:BPN28:200:SELECT PP NMS")
  field (LNK6, "QUAD:BPN28:400:SELECT PP NMS")
}
record (seq, "MGNT:BYP:1:ALLXCORSSEL"){
  field (DOL1, "MGNT:BYP:1:ALLXCORS")
  field (DOL2, "MGNT:BYP:1:ALLXCORS")
  field (DOL3, "MGNT:BYP:1:ALLXCORS")
  field (DOL4, "MGNT:BYP:1:ALLXCORS")
  field (DOL5, "MGNT:BYP:1:ALLXCORS")
  field (DOL6, "MGNT:BYP:1:ALLXCORS")
  field (DOL7, "MGNT:BYP:1:ALLXCORS")
  field (DOL8, "MGNT:BYP:1:ALLXCORS")
  field (DOL9, "MGNT:BYP:1:ALLXCORS")
  field (DOLA, "MGNT:BYP:1:ALLXCORS")
  field (LNK1, "XCOR:BPN13:406:SELECT PP NMS")
  field (LNK2, "XCOR:BPN14:406:SELECT PP NMS")
  field (LNK3, "XCOR:BPN15:406:SELECT PP NMS")
  field (LNK4, "XCOR:BPN16:406:SELECT PP NMS")
  field (LNK5, "XCOR:BPN17:406:SELECT PP NMS")
  field (LNK6, "XCOR:BPN18:406:SELECT PP NMS")
  field (LNK7, "XCOR:BPN19:406:SELECT PP NMS")
  field (LNK8, "XCOR:BPN20:406:SELECT PP NMS")
  field (LNK9, "XCOR:BPN21:406:SELECT PP NMS")
  field (LNKA, "XCOR:BPN22:406:SELECT PP NMS")
  field (FLNK, "MGNT:BYP:1:ALLXCORSSEL_2")
}
record (seq, "MGNT:BYP:1:ALLXCORSSEL_2"){
  field (DOL1, "MGNT:BYP:1:ALLXCORS")
  field (DOL2, "MGNT:BYP:1:ALLXCORS")
  field (DOL3, "MGNT:BYP:1:ALLXCORS")
  field (DOL4, "MGNT:BYP:1:ALLXCORS")
  field (DOL5, "MGNT:BYP:1:ALLXCORS")
  field (DOL6, "MGNT:BYP:1:ALLXCORS")
  field (DOL7, "MGNT:BYP:1:ALLXCORS")
  field (LNK1, "XCOR:BPN23:406:SELECT PP NMS")
  field (LNK2, "XCOR:BPN24:406:SELECT PP NMS")
  field (LNK3, "XCOR:BPN25:406:SELECT PP NMS")
  field (LNK4, "XCOR:BPN26:406:SELECT PP NMS")
  field (LNK5, "XCOR:BPN27:406:SELECT PP NMS")
  field (LNK6, "XCOR:BPN28:206:SELECT PP NMS")
  field (LNK7, "XCOR:BPN28:406:SELECT PP NMS")
}

record (seq, "MGNT:BYP:1:ALLYCORSSEL"){
  field (DOL1, "MGNT:BYP:1:ALLYCORS")
  field (DOL2, "MGNT:BYP:1:ALLYCORS")
  field (DOL3, "MGNT:BYP:1:ALLYCORS")
  field (DOL4, "MGNT:BYP:1:ALLYCORS")
  field (DOL5, "MGNT:BYP:1:ALLYCORS")
  field (DOL6, "MGNT:BYP:1:ALLYCORS")
  field (DOL7, "MGNT:BYP:1:ALLYCORS")
  field (DOL8, "MGNT:BYP:1:ALLYCORS")
  field (DOL9, "MGNT:BYP:1:ALLYCORS")
  field (DOLA, "MGNT:BYP:1:ALLYCORS")
  field (LNK1, "YCOR:BPN13:409:SELECT PP NMS")
  field (LNK2, "YCOR:BPN14:409:SELECT PP NMS")
  field (LNK3, "YCOR:BPN15:409:SELECT PP NMS")
  field (LNK4, "YCOR:BPN16:409:SELECT PP NMS")
  field (LNK5, "YCOR:BPN17:409:SELECT PP NMS")
  field (LNK6, "YCOR:BPN18:409:SELECT PP NMS")
  field (LNK7, "YCOR:BPN19:409:SELECT PP NMS")
  field (LNK8, "YCOR:BPN20:409:SELECT PP NMS")
  field (LNK9, "YCOR:BPN21:409:SELECT PP NMS")
  field (LNKA, "YCOR:BPN22:409:SELECT PP NMS")
  field (FLNK, "MGNT:BYP:1:ALLYCORSSEL_2")
}
record (seq, "MGNT:BYP:1:ALLYCORSSEL_2"){
  field (DOL1, "MGNT:BYP:1:ALLYCORS")
  field (DOL2, "MGNT:BYP:1:ALLYCORS")
  field (DOL3, "MGNT:BYP:1:ALLYCORS")
  field (DOL4, "MGNT:BYP:1:ALLYCORS")
  field (DOL5, "MGNT:BYP:1:ALLYCORS")
  field (DOL6, "MGNT:BYP:1:ALLYCORS")
  field (DOL7, "MGNT:BYP:1:ALLYCORS")
  field (LNK1, "YCOR:BPN23:409:SELECT PP NMS")
  field (LNK2, "YCOR:BPN24:409:SELECT PP NMS")
  field (LNK3, "YCOR:BPN25:409:SELECT PP NMS")
  field (LNK4, "YCOR:BPN26:409:SELECT PP NMS")
  field (LNK5, "YCOR:BPN27:409:SELECT PP NMS")
  field (LNK6, "YCOR:BPN28:209:SELECT PP NMS")
  field (LNK7, "YCOR:BPN28:409:SELECT PP NMS")
}

record (seq, "MGNT:BYP:1:ALLFUNCGO") {
  field (DESC, "Process CTRL func")

  field (DOL1, "0")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (DOL5, "1")
  field (DOL6, "1")
  field (DOL7, "1")
  field (LNK1, "MGNT:BYP:1:CTRLCLEAR.DISV")
  field (LNK2, "MGNT:BYP:1:BENDFUNCGO.PROC")
  field (LNK3, "MGNT:BYP:1:BTRMFUNCGO.PROC")
  field (LNK4, "MGNT:BYP:1:QUADFUNCGO.PROC")
  field (LNK5, "MGNT:BYP:1:XCORFUNCGO.PROC")
  field (LNK6, "MGNT:BYP:1:YCORFUNCGO.PROC")
  field (LNK7, "MGNT:BYP:1:LGPSFUNCGO.PROC")
  field (FLNK, "MGNT:BYP:1:ALLFUNCGO2")
}
record (seq, "MGNT:BYP:1:ALLFUNCGO2") {
  field (DESC, "Process CTRL func1")
  field (DOL1, "1")
  field (DOL2, "1")
  field (DOL3, "1")
  field (DOL4, "1")
  field (LNK1, "MGNT:BYP:1:SOLNFUNCGO.PROC")
  field (LNK2, "MGNT:BYP:1:KICKFUNCGO.PROC")
  field (LNK3, "MGNT:BYP:1:SEXTFUNCGO.PROC")
  field (LNK4, "MGNT:BYP:1:CTRLCLEAR.DISV")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:SOLNFUNCGO") {
  field (DESC, "Process All SOLNs")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:KICKFUNCGO") {
  field (DESC, "Process All KICKs")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:SEXTFUNCGO") {
  field (DESC, "Process All SEXTs")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:BENDFUNCGO") {
  field (DESC, "Process All BENDs")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:BTRMFUNCGO"){
  field (DESC, "Process All BTRMs")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:LGPSFUNCGO"){
  field (DESC, "Process All LGPSs")
  field (LNK1, "LGPS:BPN10:1:ALLFUNCGO")
  field (LNK2, "LGPS:BPN17:1:ALLFUNCGO")
  field (LNK3, "LGPS:BPN21:1:ALLFUNCGO")
  field (LNK4, "LGPS:BPN21:1:ALLFUNCGO")
  field (LNK5, "LGPS:BPN25:1:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:QUADFUNCGO"){
  field (DESC, "Process All QUADs")
  field (LNK1, "QUAD:DOG:575:ALLFUNCGO")
  field (LNK2, "QUAD:BPN25:400:ALLFUNCGO")
  field (LNK3, "QUAD:BPN26:400:ALLFUNCGO")
  field (LNK4, "QUAD:BPN27:400:ALLFUNCGO")
  field (LNK5, "QUAD:BPN28:200:ALLFUNCGO")
  field (LNK6, "QUAD:BPN28:400:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}
record (fanout, "MGNT:BYP:1:XCORFUNCGO"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:BPN13:406:ALLFUNCGO")
  field (LNK2, "XCOR:BPN14:406:ALLFUNCGO")
  field (LNK3, "XCOR:BPN15:406:ALLFUNCGO")
  field (LNK4, "XCOR:BPN16:406:ALLFUNCGO")
  field (LNK5, "XCOR:BPN17:406:ALLFUNCGO")
  field (LNK6, "XCOR:BPN18:406:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:XCORFUNCGO_2")
}
record (fanout, "MGNT:BYP:1:XCORFUNCGO_2"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:BPN19:406:ALLFUNCGO")
  field (LNK2, "XCOR:BPN20:406:ALLFUNCGO")
  field (LNK3, "XCOR:BPN21:406:ALLFUNCGO")
  field (LNK4, "XCOR:BPN22:406:ALLFUNCGO")
  field (LNK5, "XCOR:BPN23:406:ALLFUNCGO")
  field (LNK6, "XCOR:BPN24:406:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:XCORFUNCGO_3")
}
record (fanout, "MGNT:BYP:1:XCORFUNCGO_3"){
  field (DESC, "Process All XCORs")
  field (LNK1, "XCOR:BPN25:406:ALLFUNCGO")
  field (LNK2, "XCOR:BPN26:406:ALLFUNCGO")
  field (LNK3, "XCOR:BPN27:406:ALLFUNCGO")
  field (LNK4, "XCOR:BPN28:206:ALLFUNCGO")
  field (LNK5, "XCOR:BPN28:406:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}

record (fanout, "MGNT:BYP:1:YCORFUNCGO"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:BPN13:409:ALLFUNCGO")
  field (LNK2, "YCOR:BPN14:409:ALLFUNCGO")
  field (LNK3, "YCOR:BPN15:409:ALLFUNCGO")
  field (LNK4, "YCOR:BPN16:409:ALLFUNCGO")
  field (LNK5, "YCOR:BPN17:409:ALLFUNCGO")
  field (LNK6, "YCOR:BPN18:409:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:YCORFUNCGO_2")
}
record (fanout, "MGNT:BYP:1:YCORFUNCGO_2"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:BPN19:409:ALLFUNCGO")
  field (LNK2, "YCOR:BPN20:409:ALLFUNCGO")
  field (LNK3, "YCOR:BPN21:409:ALLFUNCGO")
  field (LNK4, "YCOR:BPN22:409:ALLFUNCGO")
  field (LNK5, "YCOR:BPN23:409:ALLFUNCGO")
  field (LNK6, "YCOR:BPN24:409:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:YCORFUNCGO_3")
}
record (fanout, "MGNT:BYP:1:YCORFUNCGO_3"){
  field (DESC, "Process All YCORs")
  field (LNK1, "YCOR:BPN25:409:ALLFUNCGO")
  field (LNK2, "YCOR:BPN26:409:ALLFUNCGO")
  field (LNK3, "YCOR:BPN27:409:ALLFUNCGO")
  field (LNK4, "YCOR:BPN28:209:ALLFUNCGO")
  field (LNK5, "YCOR:BPN28:409:ALLFUNCGO")
  field (FLNK, "MGNT:BYP:1:CTRLCLEAR")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L0B:0185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L0B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L0B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL2, "MGNT:L0B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL3, "MGNT:L0B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL4, "MGNT:L0B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL5, "MGNT:L0B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL6, "MGNT:L0B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL7, "MGNT:L0B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL8, "MGNT:L0B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L0B:0185:FUNC CA PP")
  field(DOL9, "MGNT:L0B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L0B:0185:FUNC CA PP")
  field(DOLA, "MGNT:L0B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L0B:0185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L0B:0185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L0B:0185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L0B:0185:EDES.PROC PP")
    field(LNK2, "QUAD:L0B:0185:EACT.PROC PP")
    field(LNK3, "QUAD:L0B:0185:EERR.DISA PP")
    field(LNK4, "QUAD:L0B:0185:ECON.PROC PP")
    field(LNK5, "QUAD:L0B:0185:BMAGX.PROC PP")
    field(LNK6, "QUAD:L0B:0185:BMAGY.PROC PP")
    field(LNK7, "QUAD:L0B:0185:BLEM.PROC PP")
    field(LNK8, "QUAD:L0B:0185:BMOD.PROC PP")
    field(LNK9, "QUAD:L0B:0185:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L0B:0185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L0B:0185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L0B:0185:BMAX")
  field(DOL2, "QUAD:L0B:0185:BMAX")
  field(DOL3, "QUAD:L0B:0185:BMAX")
  field(DOL4, "QUAD:L0B:0185:BMIN")
  field(DOL5, "QUAD:L0B:0185:BMIN")
  field(DOL6, "QUAD:L0B:0185:BMIN")
  field(LNK1, "QUAD:L0B:0185:BMAGX.HOPR")
  field(LNK2, "QUAD:L0B:0185:BMAGY.HOPR")
  field(LNK3, "QUAD:L0B:0185:BLEM.HOPR")
  field(LNK4, "QUAD:L0B:0185:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L0B:0185:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L0B:0185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L0B:0185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L0B:0185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L0B:0185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L0B:0185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L0B:0185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L0B:0185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L0B:0185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L0B:0185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L0B:0185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L0B:0185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L0B:0185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L0B:0185:EDES NPP MS")
  field(INPB, "QUAD:L0B:0185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L0B:0185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L0B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L0B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL2, "MGNT:L0B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL3, "MGNT:L0B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL4, "MGNT:L0B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL5, "MGNT:L0B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL6, "MGNT:L0B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL7, "MGNT:L0B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL8, "MGNT:L0B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L0B:0185:FUNC CA PP")
  field(DOL9, "MGNT:L0B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L0B:0185:FUNC CA PP")
  field(DOLA, "MGNT:L0B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L0B:0185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L0B:0185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L0B:0185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L0B:0185:EDES.PROC PP")
    field(LNK2, "XCOR:L0B:0185:EACT.PROC PP")
    field(LNK3, "XCOR:L0B:0185:EERR.DISA PP")
    field(LNK4, "XCOR:L0B:0185:ECON.PROC PP")
    field(LNK5, "XCOR:L0B:0185:BMAGX.PROC PP")
    field(LNK6, "XCOR:L0B:0185:BMAGY.PROC PP")
    field(LNK7, "XCOR:L0B:0185:BLEM.PROC PP")
    field(LNK8, "XCOR:L0B:0185:BMOD.PROC PP")
    field(LNK9, "XCOR:L0B:0185:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L0B:0185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L0B:0185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L0B:0185:BMAX")
  field(DOL2, "XCOR:L0B:0185:BMAX")
  field(DOL3, "XCOR:L0B:0185:BMAX")
  field(DOL4, "XCOR:L0B:0185:BMIN")
  field(DOL5, "XCOR:L0B:0185:BMIN")
  field(DOL6, "XCOR:L0B:0185:BMIN")
  field(LNK1, "XCOR:L0B:0185:BMAGX.HOPR")
  field(LNK2, "XCOR:L0B:0185:BMAGY.HOPR")
  field(LNK3, "XCOR:L0B:0185:BLEM.HOPR")
  field(LNK4, "XCOR:L0B:0185:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L0B:0185:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L0B:0185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L0B:0185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L0B:0185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L0B:0185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L0B:0185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L0B:0185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L0B:0185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L0B:0185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L0B:0185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L0B:0185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L0B:0185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L0B:0185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L0B:0185:EDES NPP MS")
  field(INPB, "XCOR:L0B:0185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L0B:0185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L0B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L0B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL2, "MGNT:L0B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL3, "MGNT:L0B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL4, "MGNT:L0B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL5, "MGNT:L0B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL6, "MGNT:L0B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL7, "MGNT:L0B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL8, "MGNT:L0B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L0B:0185:FUNC CA PP")
  field(DOL9, "MGNT:L0B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L0B:0185:FUNC CA PP")
  field(DOLA, "MGNT:L0B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L0B:0185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L0B:0185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L0B:0185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L0B:0185:EDES.PROC PP")
    field(LNK2, "YCOR:L0B:0185:EACT.PROC PP")
    field(LNK3, "YCOR:L0B:0185:EERR.DISA PP")
    field(LNK4, "YCOR:L0B:0185:ECON.PROC PP")
    field(LNK5, "YCOR:L0B:0185:BMAGX.PROC PP")
    field(LNK6, "YCOR:L0B:0185:BMAGY.PROC PP")
    field(LNK7, "YCOR:L0B:0185:BLEM.PROC PP")
    field(LNK8, "YCOR:L0B:0185:BMOD.PROC PP")
    field(LNK9, "YCOR:L0B:0185:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L0B:0185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L0B:0185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L0B:0185:BMAX")
  field(DOL2, "YCOR:L0B:0185:BMAX")
  field(DOL3, "YCOR:L0B:0185:BMAX")
  field(DOL4, "YCOR:L0B:0185:BMIN")
  field(DOL5, "YCOR:L0B:0185:BMIN")
  field(DOL6, "YCOR:L0B:0185:BMIN")
  field(LNK1, "YCOR:L0B:0185:BMAGX.HOPR")
  field(LNK2, "YCOR:L0B:0185:BMAGY.HOPR")
  field(LNK3, "YCOR:L0B:0185:BLEM.HOPR")
  field(LNK4, "YCOR:L0B:0185:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L0B:0185:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L0B:0185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L0B:0185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L0B:0185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L0B:0185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L0B:0185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L0B:0185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L0B:0185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L0B:0185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L0B:0185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L0B:0185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L0B:0185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L0B:0185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L0B:0185:EDES NPP MS")
  field(INPB, "YCOR:L0B:0185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:HTR:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BEND:HTR:600:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:HTR:600:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:HTR:600:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:HTR:600:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:HTR:600:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:HTR:600:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:HTR:600:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:HTR:600:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:HTR:600:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:HTR:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:HTR:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:HTR:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:HTR:600:EDES.PROC PP")
    field(LNK2, "BEND:HTR:600:EACT.PROC PP")
    field(LNK3, "BEND:HTR:600:EERR.DISA PP")
    field(LNK4, "BEND:HTR:600:ECON.PROC PP")
    field(LNK5, "BEND:HTR:600:BMAGX.PROC PP")
    field(LNK6, "BEND:HTR:600:BMAGY.PROC PP")
    field(LNK7, "BEND:HTR:600:BLEM.PROC PP")
    field(LNK8, "BEND:HTR:600:BMOD.PROC PP")
    field(LNK9, "BEND:HTR:600:EDESSAVE.PROC PP")
    field(LNKA, "BEND:HTR:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:HTR:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:HTR:600:BMAX")
  field(DOL2, "BEND:HTR:600:BMAX")
  field(DOL3, "BEND:HTR:600:BMAX")
  field(DOL4, "BEND:HTR:600:BMIN")
  field(DOL5, "BEND:HTR:600:BMIN")
  field(DOL6, "BEND:HTR:600:BMIN")
  field(LNK1, "BEND:HTR:600:BMAGX.HOPR")
  field(LNK2, "BEND:HTR:600:BMAGY.HOPR")
  field(LNK3, "BEND:HTR:600:BLEM.HOPR")
  field(LNK4, "BEND:HTR:600:BMAGX.LOPR PP")
  field(LNK5, "BEND:HTR:600:BMAGY.LOPR PP")
  field(LNK6, "BEND:HTR:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:HTR:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:HTR:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:HTR:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:HTR:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:HTR:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:HTR:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:HTR:600:EDES NPP MS")
  field(INPB, "BEND:HTR:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:HTR:480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BTRM:HTR:480:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:HTR:480:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:HTR:480:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:HTR:480:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:HTR:480:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:HTR:480:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:HTR:480:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:HTR:480:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:HTR:480:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:HTR:480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:HTR:480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:HTR:480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:HTR:480:EDES.PROC PP")
    field(LNK2, "BTRM:HTR:480:EACT.PROC PP")
    field(LNK3, "BTRM:HTR:480:EERR.DISA PP")
    field(LNK4, "BTRM:HTR:480:ECON.PROC PP")
    field(LNK5, "BTRM:HTR:480:BMAGX.PROC PP")
    field(LNK6, "BTRM:HTR:480:BMAGY.PROC PP")
    field(LNK7, "BTRM:HTR:480:BLEM.PROC PP")
    field(LNK8, "BTRM:HTR:480:BMOD.PROC PP")
    field(LNK9, "BTRM:HTR:480:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:HTR:480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:HTR:480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:HTR:480:BMAX")
  field(DOL2, "BTRM:HTR:480:BMAX")
  field(DOL3, "BTRM:HTR:480:BMAX")
  field(DOL4, "BTRM:HTR:480:BMIN")
  field(DOL5, "BTRM:HTR:480:BMIN")
  field(DOL6, "BTRM:HTR:480:BMIN")
  field(LNK1, "BTRM:HTR:480:BMAGX.HOPR")
  field(LNK2, "BTRM:HTR:480:BMAGY.HOPR")
  field(LNK3, "BTRM:HTR:480:BLEM.HOPR")
  field(LNK4, "BTRM:HTR:480:BMAGX.LOPR PP")
  field(LNK5, "BTRM:HTR:480:BMAGY.LOPR PP")
  field(LNK6, "BTRM:HTR:480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:HTR:480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:HTR:480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:HTR:480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:HTR:480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:HTR:480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:HTR:480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:HTR:480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:HTR:480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:HTR:480:EDES NPP MS")
  field(INPB, "BTRM:HTR:480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:HTR:700:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BTRM:HTR:700:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:HTR:700:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:HTR:700:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:HTR:700:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:HTR:700:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:HTR:700:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:HTR:700:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:HTR:700:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:HTR:700:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:HTR:700:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:HTR:700:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:HTR:700:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:HTR:700:EDES.PROC PP")
    field(LNK2, "BTRM:HTR:700:EACT.PROC PP")
    field(LNK3, "BTRM:HTR:700:EERR.DISA PP")
    field(LNK4, "BTRM:HTR:700:ECON.PROC PP")
    field(LNK5, "BTRM:HTR:700:BMAGX.PROC PP")
    field(LNK6, "BTRM:HTR:700:BMAGY.PROC PP")
    field(LNK7, "BTRM:HTR:700:BLEM.PROC PP")
    field(LNK8, "BTRM:HTR:700:BMOD.PROC PP")
    field(LNK9, "BTRM:HTR:700:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:HTR:700:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:HTR:700:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:HTR:700:BMAX")
  field(DOL2, "BTRM:HTR:700:BMAX")
  field(DOL3, "BTRM:HTR:700:BMAX")
  field(DOL4, "BTRM:HTR:700:BMIN")
  field(DOL5, "BTRM:HTR:700:BMIN")
  field(DOL6, "BTRM:HTR:700:BMIN")
  field(LNK1, "BTRM:HTR:700:BMAGX.HOPR")
  field(LNK2, "BTRM:HTR:700:BMAGY.HOPR")
  field(LNK3, "BTRM:HTR:700:BLEM.HOPR")
  field(LNK4, "BTRM:HTR:700:BMAGX.LOPR PP")
  field(LNK5, "BTRM:HTR:700:BMAGY.LOPR PP")
  field(LNK6, "BTRM:HTR:700:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:HTR:700:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:HTR:700:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:HTR:700:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:HTR:700:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:HTR:700:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:700:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:700:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:HTR:700:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:700:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:HTR:700:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:HTR:700:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:HTR:700:EDES NPP MS")
  field(INPB, "BTRM:HTR:700:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:HTR:820:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BTRM:HTR:820:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:HTR:820:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:HTR:820:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:HTR:820:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:HTR:820:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:HTR:820:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:HTR:820:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:HTR:820:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:HTR:820:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:HTR:820:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:HTR:820:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:HTR:820:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:HTR:820:EDES.PROC PP")
    field(LNK2, "BTRM:HTR:820:EACT.PROC PP")
    field(LNK3, "BTRM:HTR:820:EERR.DISA PP")
    field(LNK4, "BTRM:HTR:820:ECON.PROC PP")
    field(LNK5, "BTRM:HTR:820:BMAGX.PROC PP")
    field(LNK6, "BTRM:HTR:820:BMAGY.PROC PP")
    field(LNK7, "BTRM:HTR:820:BLEM.PROC PP")
    field(LNK8, "BTRM:HTR:820:BMOD.PROC PP")
    field(LNK9, "BTRM:HTR:820:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:HTR:820:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:HTR:820:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:HTR:820:BMAX")
  field(DOL2, "BTRM:HTR:820:BMAX")
  field(DOL3, "BTRM:HTR:820:BMAX")
  field(DOL4, "BTRM:HTR:820:BMIN")
  field(DOL5, "BTRM:HTR:820:BMIN")
  field(DOL6, "BTRM:HTR:820:BMIN")
  field(LNK1, "BTRM:HTR:820:BMAGX.HOPR")
  field(LNK2, "BTRM:HTR:820:BMAGY.HOPR")
  field(LNK3, "BTRM:HTR:820:BLEM.HOPR")
  field(LNK4, "BTRM:HTR:820:BMAGX.LOPR PP")
  field(LNK5, "BTRM:HTR:820:BMAGY.LOPR PP")
  field(LNK6, "BTRM:HTR:820:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:HTR:820:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:HTR:820:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:HTR:820:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:HTR:820:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:HTR:820:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:820:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:820:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:HTR:820:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:HTR:820:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:HTR:820:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:HTR:820:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:HTR:820:EDES NPP MS")
  field(INPB, "BTRM:HTR:820:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:120:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:120:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:120:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:120:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:120:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:120:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:120:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:120:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:120:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:120:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:120:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:120:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:120:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:120:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:120:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:120:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:120:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:120:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:120:BMAX")
  field(DOL2, "QUAD:HTR:120:BMAX")
  field(DOL3, "QUAD:HTR:120:BMAX")
  field(DOL4, "QUAD:HTR:120:BMIN")
  field(DOL5, "QUAD:HTR:120:BMIN")
  field(DOL6, "QUAD:HTR:120:BMIN")
  field(LNK1, "QUAD:HTR:120:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:120:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:120:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:120:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:120:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:120:EDES NPP MS")
  field(INPB, "QUAD:HTR:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:140:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:140:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:140:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:140:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:140:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:140:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:140:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:140:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:140:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:140:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:140:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:140:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:140:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:140:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:140:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:140:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:140:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:140:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:140:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:140:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:140:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:140:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:140:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:140:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:140:BMAX")
  field(DOL2, "QUAD:HTR:140:BMAX")
  field(DOL3, "QUAD:HTR:140:BMAX")
  field(DOL4, "QUAD:HTR:140:BMIN")
  field(DOL5, "QUAD:HTR:140:BMIN")
  field(DOL6, "QUAD:HTR:140:BMIN")
  field(LNK1, "QUAD:HTR:140:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:140:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:140:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:140:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:140:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:140:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:140:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:140:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:140:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:140:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:140:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:140:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:140:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:140:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:140:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:140:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:140:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:140:EDES NPP MS")
  field(INPB, "QUAD:HTR:140:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:300:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:300:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:300:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:300:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:300:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:300:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:300:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:300:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:300:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:300:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:300:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:300:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:300:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:300:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:300:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:300:BMAX")
  field(DOL2, "QUAD:HTR:300:BMAX")
  field(DOL3, "QUAD:HTR:300:BMAX")
  field(DOL4, "QUAD:HTR:300:BMIN")
  field(DOL5, "QUAD:HTR:300:BMIN")
  field(DOL6, "QUAD:HTR:300:BMIN")
  field(LNK1, "QUAD:HTR:300:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:300:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:300:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:300:EDES NPP MS")
  field(INPB, "QUAD:HTR:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:320:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:320:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:320:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:320:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:320:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:320:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:320:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:320:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:320:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:320:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:320:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:320:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:320:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:320:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:320:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:320:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:320:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:320:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:320:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:320:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:320:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:320:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:320:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:320:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:320:BMAX")
  field(DOL2, "QUAD:HTR:320:BMAX")
  field(DOL3, "QUAD:HTR:320:BMAX")
  field(DOL4, "QUAD:HTR:320:BMIN")
  field(DOL5, "QUAD:HTR:320:BMIN")
  field(DOL6, "QUAD:HTR:320:BMIN")
  field(LNK1, "QUAD:HTR:320:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:320:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:320:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:320:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:320:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:320:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:320:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:320:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:320:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:320:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:320:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:320:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:320:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:320:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:320:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:320:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:320:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:320:EDES NPP MS")
  field(INPB, "QUAD:HTR:320:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:365:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:365:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:365:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:365:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:365:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:365:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:365:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:365:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:365:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:365:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:365:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:365:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:365:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:365:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:365:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:365:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:365:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:365:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:365:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:365:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:365:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:365:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:365:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:365:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:365:BMAX")
  field(DOL2, "QUAD:HTR:365:BMAX")
  field(DOL3, "QUAD:HTR:365:BMAX")
  field(DOL4, "QUAD:HTR:365:BMIN")
  field(DOL5, "QUAD:HTR:365:BMIN")
  field(DOL6, "QUAD:HTR:365:BMIN")
  field(LNK1, "QUAD:HTR:365:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:365:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:365:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:365:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:365:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:365:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:365:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:365:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:365:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:365:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:365:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:365:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:365:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:365:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:365:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:365:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:365:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:365:EDES NPP MS")
  field(INPB, "QUAD:HTR:365:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:385:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:385:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:385:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:385:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:385:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:385:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:385:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:385:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:385:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:385:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:385:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:385:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:385:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:385:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:385:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:385:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:385:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:385:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:385:BMAX")
  field(DOL2, "QUAD:HTR:385:BMAX")
  field(DOL3, "QUAD:HTR:385:BMAX")
  field(DOL4, "QUAD:HTR:385:BMIN")
  field(DOL5, "QUAD:HTR:385:BMIN")
  field(DOL6, "QUAD:HTR:385:BMIN")
  field(LNK1, "QUAD:HTR:385:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:385:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:385:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:385:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:385:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:385:EDES NPP MS")
  field(INPB, "QUAD:HTR:385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:440:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:440:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:440:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:440:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:440:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:440:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:440:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:440:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:440:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:440:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:440:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:440:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:440:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:440:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:440:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:440:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:440:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:440:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:440:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:440:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:440:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:440:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:440:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:440:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:440:BMAX")
  field(DOL2, "QUAD:HTR:440:BMAX")
  field(DOL3, "QUAD:HTR:440:BMAX")
  field(DOL4, "QUAD:HTR:440:BMIN")
  field(DOL5, "QUAD:HTR:440:BMIN")
  field(DOL6, "QUAD:HTR:440:BMIN")
  field(LNK1, "QUAD:HTR:440:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:440:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:440:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:440:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:440:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:440:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:440:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:440:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:440:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:440:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:440:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:440:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:440:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:440:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:440:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:440:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:440:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:440:EDES NPP MS")
  field(INPB, "QUAD:HTR:440:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:460:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:460:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:460:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:460:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:460:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:460:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:460:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:460:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:460:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:460:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:460:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:460:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:460:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:460:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:460:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:460:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:460:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:460:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:460:BMAX")
  field(DOL2, "QUAD:HTR:460:BMAX")
  field(DOL3, "QUAD:HTR:460:BMAX")
  field(DOL4, "QUAD:HTR:460:BMIN")
  field(DOL5, "QUAD:HTR:460:BMIN")
  field(DOL6, "QUAD:HTR:460:BMIN")
  field(LNK1, "QUAD:HTR:460:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:460:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:460:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:460:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:460:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:460:EDES NPP MS")
  field(INPB, "QUAD:HTR:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:830:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:830:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:830:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:830:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:830:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:830:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:830:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:830:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:830:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:830:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:830:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:830:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:830:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:830:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:830:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:830:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:830:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:830:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:830:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:830:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:830:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:830:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:830:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:830:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:830:BMAX")
  field(DOL2, "QUAD:HTR:830:BMAX")
  field(DOL3, "QUAD:HTR:830:BMAX")
  field(DOL4, "QUAD:HTR:830:BMIN")
  field(DOL5, "QUAD:HTR:830:BMIN")
  field(DOL6, "QUAD:HTR:830:BMIN")
  field(LNK1, "QUAD:HTR:830:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:830:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:830:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:830:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:830:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:830:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:830:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:830:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:830:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:830:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:830:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:830:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:830:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:830:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:830:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:830:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:830:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:830:EDES NPP MS")
  field(INPB, "QUAD:HTR:830:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:860:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:860:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:860:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:860:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:860:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:860:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:860:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:860:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:860:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:860:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:860:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:860:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:860:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:860:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:860:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:860:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:860:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:860:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:860:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:860:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:860:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:860:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:860:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:860:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:860:BMAX")
  field(DOL2, "QUAD:HTR:860:BMAX")
  field(DOL3, "QUAD:HTR:860:BMAX")
  field(DOL4, "QUAD:HTR:860:BMIN")
  field(DOL5, "QUAD:HTR:860:BMIN")
  field(DOL6, "QUAD:HTR:860:BMIN")
  field(LNK1, "QUAD:HTR:860:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:860:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:860:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:860:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:860:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:860:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:860:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:860:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:860:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:860:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:860:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:860:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:860:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:860:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:860:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:860:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:860:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:860:EDES NPP MS")
  field(INPB, "QUAD:HTR:860:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:960:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:960:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:960:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:960:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:960:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:960:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:960:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:960:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:960:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:960:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:960:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:960:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:960:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:960:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:960:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:960:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:960:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:960:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:960:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:960:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:960:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:960:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:960:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:960:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:960:BMAX")
  field(DOL2, "QUAD:HTR:960:BMAX")
  field(DOL3, "QUAD:HTR:960:BMAX")
  field(DOL4, "QUAD:HTR:960:BMIN")
  field(DOL5, "QUAD:HTR:960:BMIN")
  field(DOL6, "QUAD:HTR:960:BMIN")
  field(LNK1, "QUAD:HTR:960:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:960:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:960:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:960:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:960:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:960:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:960:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:960:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:960:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:960:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:960:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:960:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:960:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:960:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:960:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:960:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:960:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:960:EDES NPP MS")
  field(INPB, "QUAD:HTR:960:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:HTR:980:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "QUAD:HTR:980:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:HTR:980:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:HTR:980:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:HTR:980:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:HTR:980:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:HTR:980:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:HTR:980:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:HTR:980:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:HTR:980:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:HTR:980:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:HTR:980:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:HTR:980:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:HTR:980:EDES.PROC PP")
    field(LNK2, "QUAD:HTR:980:EACT.PROC PP")
    field(LNK3, "QUAD:HTR:980:EERR.DISA PP")
    field(LNK4, "QUAD:HTR:980:ECON.PROC PP")
    field(LNK5, "QUAD:HTR:980:BMAGX.PROC PP")
    field(LNK6, "QUAD:HTR:980:BMAGY.PROC PP")
    field(LNK7, "QUAD:HTR:980:BLEM.PROC PP")
    field(LNK8, "QUAD:HTR:980:BMOD.PROC PP")
    field(LNK9, "QUAD:HTR:980:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:HTR:980:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:HTR:980:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:HTR:980:BMAX")
  field(DOL2, "QUAD:HTR:980:BMAX")
  field(DOL3, "QUAD:HTR:980:BMAX")
  field(DOL4, "QUAD:HTR:980:BMIN")
  field(DOL5, "QUAD:HTR:980:BMIN")
  field(DOL6, "QUAD:HTR:980:BMIN")
  field(LNK1, "QUAD:HTR:980:BMAGX.HOPR")
  field(LNK2, "QUAD:HTR:980:BMAGY.HOPR")
  field(LNK3, "QUAD:HTR:980:BLEM.HOPR")
  field(LNK4, "QUAD:HTR:980:BMAGX.LOPR PP")
  field(LNK5, "QUAD:HTR:980:BMAGY.LOPR PP")
  field(LNK6, "QUAD:HTR:980:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:980:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:HTR:980:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:HTR:980:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:HTR:980:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:HTR:980:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:980:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:980:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:980:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:HTR:980:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:HTR:980:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:HTR:980:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:HTR:980:EDES NPP MS")
  field(INPB, "QUAD:HTR:980:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:HTR:148:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "XCOR:HTR:148:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:HTR:148:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:HTR:148:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:HTR:148:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:HTR:148:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:HTR:148:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:HTR:148:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:HTR:148:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:HTR:148:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:HTR:148:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:HTR:148:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:HTR:148:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:HTR:148:EDES.PROC PP")
    field(LNK2, "XCOR:HTR:148:EACT.PROC PP")
    field(LNK3, "XCOR:HTR:148:EERR.DISA PP")
    field(LNK4, "XCOR:HTR:148:ECON.PROC PP")
    field(LNK5, "XCOR:HTR:148:BMAGX.PROC PP")
    field(LNK6, "XCOR:HTR:148:BMAGY.PROC PP")
    field(LNK7, "XCOR:HTR:148:BLEM.PROC PP")
    field(LNK8, "XCOR:HTR:148:BMOD.PROC PP")
    field(LNK9, "XCOR:HTR:148:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:HTR:148:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:HTR:148:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:HTR:148:BMAX")
  field(DOL2, "XCOR:HTR:148:BMAX")
  field(DOL3, "XCOR:HTR:148:BMAX")
  field(DOL4, "XCOR:HTR:148:BMIN")
  field(DOL5, "XCOR:HTR:148:BMIN")
  field(DOL6, "XCOR:HTR:148:BMIN")
  field(LNK1, "XCOR:HTR:148:BMAGX.HOPR")
  field(LNK2, "XCOR:HTR:148:BMAGY.HOPR")
  field(LNK3, "XCOR:HTR:148:BLEM.HOPR")
  field(LNK4, "XCOR:HTR:148:BMAGX.LOPR PP")
  field(LNK5, "XCOR:HTR:148:BMAGY.LOPR PP")
  field(LNK6, "XCOR:HTR:148:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:148:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:148:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:HTR:148:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:HTR:148:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:HTR:148:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:148:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:148:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:148:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:148:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:148:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:HTR:148:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:HTR:148:EDES NPP MS")
  field(INPB, "XCOR:HTR:148:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:HTR:288:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "XCOR:HTR:288:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:HTR:288:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:HTR:288:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:HTR:288:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:HTR:288:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:HTR:288:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:HTR:288:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:HTR:288:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:HTR:288:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:HTR:288:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:HTR:288:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:HTR:288:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:HTR:288:EDES.PROC PP")
    field(LNK2, "XCOR:HTR:288:EACT.PROC PP")
    field(LNK3, "XCOR:HTR:288:EERR.DISA PP")
    field(LNK4, "XCOR:HTR:288:ECON.PROC PP")
    field(LNK5, "XCOR:HTR:288:BMAGX.PROC PP")
    field(LNK6, "XCOR:HTR:288:BMAGY.PROC PP")
    field(LNK7, "XCOR:HTR:288:BLEM.PROC PP")
    field(LNK8, "XCOR:HTR:288:BMOD.PROC PP")
    field(LNK9, "XCOR:HTR:288:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:HTR:288:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:HTR:288:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:HTR:288:BMAX")
  field(DOL2, "XCOR:HTR:288:BMAX")
  field(DOL3, "XCOR:HTR:288:BMAX")
  field(DOL4, "XCOR:HTR:288:BMIN")
  field(DOL5, "XCOR:HTR:288:BMIN")
  field(DOL6, "XCOR:HTR:288:BMIN")
  field(LNK1, "XCOR:HTR:288:BMAGX.HOPR")
  field(LNK2, "XCOR:HTR:288:BMAGY.HOPR")
  field(LNK3, "XCOR:HTR:288:BLEM.HOPR")
  field(LNK4, "XCOR:HTR:288:BMAGX.LOPR PP")
  field(LNK5, "XCOR:HTR:288:BMAGY.LOPR PP")
  field(LNK6, "XCOR:HTR:288:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:288:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:288:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:HTR:288:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:HTR:288:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:HTR:288:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:288:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:288:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:288:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:288:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:288:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:HTR:288:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:HTR:288:EDES NPP MS")
  field(INPB, "XCOR:HTR:288:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:HTR:396:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "XCOR:HTR:396:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:HTR:396:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:HTR:396:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:HTR:396:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:HTR:396:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:HTR:396:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:HTR:396:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:HTR:396:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:HTR:396:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:HTR:396:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:HTR:396:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:HTR:396:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:HTR:396:EDES.PROC PP")
    field(LNK2, "XCOR:HTR:396:EACT.PROC PP")
    field(LNK3, "XCOR:HTR:396:EERR.DISA PP")
    field(LNK4, "XCOR:HTR:396:ECON.PROC PP")
    field(LNK5, "XCOR:HTR:396:BMAGX.PROC PP")
    field(LNK6, "XCOR:HTR:396:BMAGY.PROC PP")
    field(LNK7, "XCOR:HTR:396:BLEM.PROC PP")
    field(LNK8, "XCOR:HTR:396:BMOD.PROC PP")
    field(LNK9, "XCOR:HTR:396:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:HTR:396:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:HTR:396:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:HTR:396:BMAX")
  field(DOL2, "XCOR:HTR:396:BMAX")
  field(DOL3, "XCOR:HTR:396:BMAX")
  field(DOL4, "XCOR:HTR:396:BMIN")
  field(DOL5, "XCOR:HTR:396:BMIN")
  field(DOL6, "XCOR:HTR:396:BMIN")
  field(LNK1, "XCOR:HTR:396:BMAGX.HOPR")
  field(LNK2, "XCOR:HTR:396:BMAGY.HOPR")
  field(LNK3, "XCOR:HTR:396:BLEM.HOPR")
  field(LNK4, "XCOR:HTR:396:BMAGX.LOPR PP")
  field(LNK5, "XCOR:HTR:396:BMAGY.LOPR PP")
  field(LNK6, "XCOR:HTR:396:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:396:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:396:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:HTR:396:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:HTR:396:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:HTR:396:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:396:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:396:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:396:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:396:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:396:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:HTR:396:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:HTR:396:EDES NPP MS")
  field(INPB, "XCOR:HTR:396:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:HTR:428:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "XCOR:HTR:428:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:HTR:428:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:HTR:428:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:HTR:428:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:HTR:428:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:HTR:428:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:HTR:428:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:HTR:428:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:HTR:428:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:HTR:428:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:HTR:428:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:HTR:428:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:HTR:428:EDES.PROC PP")
    field(LNK2, "XCOR:HTR:428:EACT.PROC PP")
    field(LNK3, "XCOR:HTR:428:EERR.DISA PP")
    field(LNK4, "XCOR:HTR:428:ECON.PROC PP")
    field(LNK5, "XCOR:HTR:428:BMAGX.PROC PP")
    field(LNK6, "XCOR:HTR:428:BMAGY.PROC PP")
    field(LNK7, "XCOR:HTR:428:BLEM.PROC PP")
    field(LNK8, "XCOR:HTR:428:BMOD.PROC PP")
    field(LNK9, "XCOR:HTR:428:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:HTR:428:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:HTR:428:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:HTR:428:BMAX")
  field(DOL2, "XCOR:HTR:428:BMAX")
  field(DOL3, "XCOR:HTR:428:BMAX")
  field(DOL4, "XCOR:HTR:428:BMIN")
  field(DOL5, "XCOR:HTR:428:BMIN")
  field(DOL6, "XCOR:HTR:428:BMIN")
  field(LNK1, "XCOR:HTR:428:BMAGX.HOPR")
  field(LNK2, "XCOR:HTR:428:BMAGY.HOPR")
  field(LNK3, "XCOR:HTR:428:BLEM.HOPR")
  field(LNK4, "XCOR:HTR:428:BMAGX.LOPR PP")
  field(LNK5, "XCOR:HTR:428:BMAGY.LOPR PP")
  field(LNK6, "XCOR:HTR:428:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:428:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:428:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:HTR:428:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:HTR:428:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:HTR:428:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:428:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:428:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:428:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:428:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:428:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:HTR:428:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:HTR:428:EDES NPP MS")
  field(INPB, "XCOR:HTR:428:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:HTR:848:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "XCOR:HTR:848:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:HTR:848:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:HTR:848:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:HTR:848:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:HTR:848:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:HTR:848:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:HTR:848:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:HTR:848:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:HTR:848:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:HTR:848:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:HTR:848:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:HTR:848:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:HTR:848:EDES.PROC PP")
    field(LNK2, "XCOR:HTR:848:EACT.PROC PP")
    field(LNK3, "XCOR:HTR:848:EERR.DISA PP")
    field(LNK4, "XCOR:HTR:848:ECON.PROC PP")
    field(LNK5, "XCOR:HTR:848:BMAGX.PROC PP")
    field(LNK6, "XCOR:HTR:848:BMAGY.PROC PP")
    field(LNK7, "XCOR:HTR:848:BLEM.PROC PP")
    field(LNK8, "XCOR:HTR:848:BMOD.PROC PP")
    field(LNK9, "XCOR:HTR:848:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:HTR:848:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:HTR:848:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:HTR:848:BMAX")
  field(DOL2, "XCOR:HTR:848:BMAX")
  field(DOL3, "XCOR:HTR:848:BMAX")
  field(DOL4, "XCOR:HTR:848:BMIN")
  field(DOL5, "XCOR:HTR:848:BMIN")
  field(DOL6, "XCOR:HTR:848:BMIN")
  field(LNK1, "XCOR:HTR:848:BMAGX.HOPR")
  field(LNK2, "XCOR:HTR:848:BMAGY.HOPR")
  field(LNK3, "XCOR:HTR:848:BLEM.HOPR")
  field(LNK4, "XCOR:HTR:848:BMAGX.LOPR PP")
  field(LNK5, "XCOR:HTR:848:BMAGY.LOPR PP")
  field(LNK6, "XCOR:HTR:848:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:848:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:848:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:HTR:848:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:HTR:848:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:HTR:848:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:848:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:848:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:848:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:848:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:848:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:HTR:848:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:HTR:848:EDES NPP MS")
  field(INPB, "XCOR:HTR:848:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:HTR:974:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "XCOR:HTR:974:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:HTR:974:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:HTR:974:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:HTR:974:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:HTR:974:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:HTR:974:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:HTR:974:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:HTR:974:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:HTR:974:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:HTR:974:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:HTR:974:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:HTR:974:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:HTR:974:EDES.PROC PP")
    field(LNK2, "XCOR:HTR:974:EACT.PROC PP")
    field(LNK3, "XCOR:HTR:974:EERR.DISA PP")
    field(LNK4, "XCOR:HTR:974:ECON.PROC PP")
    field(LNK5, "XCOR:HTR:974:BMAGX.PROC PP")
    field(LNK6, "XCOR:HTR:974:BMAGY.PROC PP")
    field(LNK7, "XCOR:HTR:974:BLEM.PROC PP")
    field(LNK8, "XCOR:HTR:974:BMOD.PROC PP")
    field(LNK9, "XCOR:HTR:974:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:HTR:974:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:HTR:974:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:HTR:974:BMAX")
  field(DOL2, "XCOR:HTR:974:BMAX")
  field(DOL3, "XCOR:HTR:974:BMAX")
  field(DOL4, "XCOR:HTR:974:BMIN")
  field(DOL5, "XCOR:HTR:974:BMIN")
  field(DOL6, "XCOR:HTR:974:BMIN")
  field(LNK1, "XCOR:HTR:974:BMAGX.HOPR")
  field(LNK2, "XCOR:HTR:974:BMAGY.HOPR")
  field(LNK3, "XCOR:HTR:974:BLEM.HOPR")
  field(LNK4, "XCOR:HTR:974:BMAGX.LOPR PP")
  field(LNK5, "XCOR:HTR:974:BMAGY.LOPR PP")
  field(LNK6, "XCOR:HTR:974:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:974:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:HTR:974:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:HTR:974:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:HTR:974:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:HTR:974:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:974:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:974:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:974:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:HTR:974:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:HTR:974:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:HTR:974:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:HTR:974:EDES NPP MS")
  field(INPB, "XCOR:HTR:974:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:HTR:129:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "YCOR:HTR:129:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:HTR:129:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:HTR:129:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:HTR:129:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:HTR:129:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:HTR:129:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:HTR:129:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:HTR:129:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:HTR:129:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:HTR:129:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:HTR:129:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:HTR:129:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:HTR:129:EDES.PROC PP")
    field(LNK2, "YCOR:HTR:129:EACT.PROC PP")
    field(LNK3, "YCOR:HTR:129:EERR.DISA PP")
    field(LNK4, "YCOR:HTR:129:ECON.PROC PP")
    field(LNK5, "YCOR:HTR:129:BMAGX.PROC PP")
    field(LNK6, "YCOR:HTR:129:BMAGY.PROC PP")
    field(LNK7, "YCOR:HTR:129:BLEM.PROC PP")
    field(LNK8, "YCOR:HTR:129:BMOD.PROC PP")
    field(LNK9, "YCOR:HTR:129:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:HTR:129:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:HTR:129:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:HTR:129:BMAX")
  field(DOL2, "YCOR:HTR:129:BMAX")
  field(DOL3, "YCOR:HTR:129:BMAX")
  field(DOL4, "YCOR:HTR:129:BMIN")
  field(DOL5, "YCOR:HTR:129:BMIN")
  field(DOL6, "YCOR:HTR:129:BMIN")
  field(LNK1, "YCOR:HTR:129:BMAGX.HOPR")
  field(LNK2, "YCOR:HTR:129:BMAGY.HOPR")
  field(LNK3, "YCOR:HTR:129:BLEM.HOPR")
  field(LNK4, "YCOR:HTR:129:BMAGX.LOPR PP")
  field(LNK5, "YCOR:HTR:129:BMAGY.LOPR PP")
  field(LNK6, "YCOR:HTR:129:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:129:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:129:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:HTR:129:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:HTR:129:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:HTR:129:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:129:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:129:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:129:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:129:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:129:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:HTR:129:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:HTR:129:EDES NPP MS")
  field(INPB, "YCOR:HTR:129:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:HTR:309:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "YCOR:HTR:309:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:HTR:309:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:HTR:309:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:HTR:309:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:HTR:309:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:HTR:309:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:HTR:309:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:HTR:309:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:HTR:309:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:HTR:309:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:HTR:309:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:HTR:309:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:HTR:309:EDES.PROC PP")
    field(LNK2, "YCOR:HTR:309:EACT.PROC PP")
    field(LNK3, "YCOR:HTR:309:EERR.DISA PP")
    field(LNK4, "YCOR:HTR:309:ECON.PROC PP")
    field(LNK5, "YCOR:HTR:309:BMAGX.PROC PP")
    field(LNK6, "YCOR:HTR:309:BMAGY.PROC PP")
    field(LNK7, "YCOR:HTR:309:BLEM.PROC PP")
    field(LNK8, "YCOR:HTR:309:BMOD.PROC PP")
    field(LNK9, "YCOR:HTR:309:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:HTR:309:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:HTR:309:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:HTR:309:BMAX")
  field(DOL2, "YCOR:HTR:309:BMAX")
  field(DOL3, "YCOR:HTR:309:BMAX")
  field(DOL4, "YCOR:HTR:309:BMIN")
  field(DOL5, "YCOR:HTR:309:BMIN")
  field(DOL6, "YCOR:HTR:309:BMIN")
  field(LNK1, "YCOR:HTR:309:BMAGX.HOPR")
  field(LNK2, "YCOR:HTR:309:BMAGY.HOPR")
  field(LNK3, "YCOR:HTR:309:BLEM.HOPR")
  field(LNK4, "YCOR:HTR:309:BMAGX.LOPR PP")
  field(LNK5, "YCOR:HTR:309:BMAGY.LOPR PP")
  field(LNK6, "YCOR:HTR:309:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:309:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:309:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:HTR:309:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:HTR:309:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:HTR:309:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:309:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:309:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:309:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:309:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:309:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:HTR:309:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:HTR:309:EDES NPP MS")
  field(INPB, "YCOR:HTR:309:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:HTR:377:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "YCOR:HTR:377:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:HTR:377:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:HTR:377:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:HTR:377:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:HTR:377:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:HTR:377:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:HTR:377:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:HTR:377:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:HTR:377:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:HTR:377:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:HTR:377:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:HTR:377:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:HTR:377:EDES.PROC PP")
    field(LNK2, "YCOR:HTR:377:EACT.PROC PP")
    field(LNK3, "YCOR:HTR:377:EERR.DISA PP")
    field(LNK4, "YCOR:HTR:377:ECON.PROC PP")
    field(LNK5, "YCOR:HTR:377:BMAGX.PROC PP")
    field(LNK6, "YCOR:HTR:377:BMAGY.PROC PP")
    field(LNK7, "YCOR:HTR:377:BLEM.PROC PP")
    field(LNK8, "YCOR:HTR:377:BMOD.PROC PP")
    field(LNK9, "YCOR:HTR:377:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:HTR:377:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:HTR:377:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:HTR:377:BMAX")
  field(DOL2, "YCOR:HTR:377:BMAX")
  field(DOL3, "YCOR:HTR:377:BMAX")
  field(DOL4, "YCOR:HTR:377:BMIN")
  field(DOL5, "YCOR:HTR:377:BMIN")
  field(DOL6, "YCOR:HTR:377:BMIN")
  field(LNK1, "YCOR:HTR:377:BMAGX.HOPR")
  field(LNK2, "YCOR:HTR:377:BMAGY.HOPR")
  field(LNK3, "YCOR:HTR:377:BLEM.HOPR")
  field(LNK4, "YCOR:HTR:377:BMAGX.LOPR PP")
  field(LNK5, "YCOR:HTR:377:BMAGY.LOPR PP")
  field(LNK6, "YCOR:HTR:377:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:377:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:377:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:HTR:377:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:HTR:377:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:HTR:377:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:377:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:377:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:377:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:377:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:377:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:HTR:377:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:HTR:377:EDES NPP MS")
  field(INPB, "YCOR:HTR:377:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:HTR:451:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "YCOR:HTR:451:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:HTR:451:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:HTR:451:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:HTR:451:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:HTR:451:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:HTR:451:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:HTR:451:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:HTR:451:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:HTR:451:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:HTR:451:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:HTR:451:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:HTR:451:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:HTR:451:EDES.PROC PP")
    field(LNK2, "YCOR:HTR:451:EACT.PROC PP")
    field(LNK3, "YCOR:HTR:451:EERR.DISA PP")
    field(LNK4, "YCOR:HTR:451:ECON.PROC PP")
    field(LNK5, "YCOR:HTR:451:BMAGX.PROC PP")
    field(LNK6, "YCOR:HTR:451:BMAGY.PROC PP")
    field(LNK7, "YCOR:HTR:451:BLEM.PROC PP")
    field(LNK8, "YCOR:HTR:451:BMOD.PROC PP")
    field(LNK9, "YCOR:HTR:451:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:HTR:451:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:HTR:451:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:HTR:451:BMAX")
  field(DOL2, "YCOR:HTR:451:BMAX")
  field(DOL3, "YCOR:HTR:451:BMAX")
  field(DOL4, "YCOR:HTR:451:BMIN")
  field(DOL5, "YCOR:HTR:451:BMIN")
  field(DOL6, "YCOR:HTR:451:BMIN")
  field(LNK1, "YCOR:HTR:451:BMAGX.HOPR")
  field(LNK2, "YCOR:HTR:451:BMAGY.HOPR")
  field(LNK3, "YCOR:HTR:451:BLEM.HOPR")
  field(LNK4, "YCOR:HTR:451:BMAGX.LOPR PP")
  field(LNK5, "YCOR:HTR:451:BMAGY.LOPR PP")
  field(LNK6, "YCOR:HTR:451:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:451:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:451:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:HTR:451:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:HTR:451:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:HTR:451:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:451:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:451:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:451:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:451:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:451:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:HTR:451:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:HTR:451:EDES NPP MS")
  field(INPB, "YCOR:HTR:451:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:HTR:841:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "YCOR:HTR:841:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:HTR:841:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:HTR:841:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:HTR:841:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:HTR:841:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:HTR:841:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:HTR:841:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:HTR:841:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:HTR:841:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:HTR:841:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:HTR:841:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:HTR:841:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:HTR:841:EDES.PROC PP")
    field(LNK2, "YCOR:HTR:841:EACT.PROC PP")
    field(LNK3, "YCOR:HTR:841:EERR.DISA PP")
    field(LNK4, "YCOR:HTR:841:ECON.PROC PP")
    field(LNK5, "YCOR:HTR:841:BMAGX.PROC PP")
    field(LNK6, "YCOR:HTR:841:BMAGY.PROC PP")
    field(LNK7, "YCOR:HTR:841:BLEM.PROC PP")
    field(LNK8, "YCOR:HTR:841:BMOD.PROC PP")
    field(LNK9, "YCOR:HTR:841:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:HTR:841:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:HTR:841:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:HTR:841:BMAX")
  field(DOL2, "YCOR:HTR:841:BMAX")
  field(DOL3, "YCOR:HTR:841:BMAX")
  field(DOL4, "YCOR:HTR:841:BMIN")
  field(DOL5, "YCOR:HTR:841:BMIN")
  field(DOL6, "YCOR:HTR:841:BMIN")
  field(LNK1, "YCOR:HTR:841:BMAGX.HOPR")
  field(LNK2, "YCOR:HTR:841:BMAGY.HOPR")
  field(LNK3, "YCOR:HTR:841:BLEM.HOPR")
  field(LNK4, "YCOR:HTR:841:BMAGX.LOPR PP")
  field(LNK5, "YCOR:HTR:841:BMAGY.LOPR PP")
  field(LNK6, "YCOR:HTR:841:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:841:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:841:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:HTR:841:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:HTR:841:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:HTR:841:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:841:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:841:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:841:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:841:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:841:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:HTR:841:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:HTR:841:EDES NPP MS")
  field(INPB, "YCOR:HTR:841:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:HTR:951:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "YCOR:HTR:951:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:HTR:951:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:HTR:951:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:HTR:951:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:HTR:951:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:HTR:951:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:HTR:951:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:HTR:951:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:HTR:951:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:HTR:951:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:HTR:951:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:HTR:951:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:HTR:951:EDES.PROC PP")
    field(LNK2, "YCOR:HTR:951:EACT.PROC PP")
    field(LNK3, "YCOR:HTR:951:EERR.DISA PP")
    field(LNK4, "YCOR:HTR:951:ECON.PROC PP")
    field(LNK5, "YCOR:HTR:951:BMAGX.PROC PP")
    field(LNK6, "YCOR:HTR:951:BMAGY.PROC PP")
    field(LNK7, "YCOR:HTR:951:BLEM.PROC PP")
    field(LNK8, "YCOR:HTR:951:BMOD.PROC PP")
    field(LNK9, "YCOR:HTR:951:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:HTR:951:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:HTR:951:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:HTR:951:BMAX")
  field(DOL2, "YCOR:HTR:951:BMAX")
  field(DOL3, "YCOR:HTR:951:BMAX")
  field(DOL4, "YCOR:HTR:951:BMIN")
  field(DOL5, "YCOR:HTR:951:BMIN")
  field(DOL6, "YCOR:HTR:951:BMIN")
  field(LNK1, "YCOR:HTR:951:BMAGX.HOPR")
  field(LNK2, "YCOR:HTR:951:BMAGY.HOPR")
  field(LNK3, "YCOR:HTR:951:BLEM.HOPR")
  field(LNK4, "YCOR:HTR:951:BMAGX.LOPR PP")
  field(LNK5, "YCOR:HTR:951:BMAGY.LOPR PP")
  field(LNK6, "YCOR:HTR:951:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:951:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:HTR:951:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:HTR:951:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:HTR:951:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:HTR:951:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:951:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:951:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:951:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:HTR:951:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:HTR:951:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:HTR:951:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:HTR:951:EDES NPP MS")
  field(INPB, "YCOR:HTR:951:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:240:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:240:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:240:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:240:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:240:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:240:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:240:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:240:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:240:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:240:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:240:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:240:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:240:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:240:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:240:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:240:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:240:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:240:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:240:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:240:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:240:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:240:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:240:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:240:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:240:BMAX")
  field(DOL2, "QUAD:COL0:240:BMAX")
  field(DOL3, "QUAD:COL0:240:BMAX")
  field(DOL4, "QUAD:COL0:240:BMIN")
  field(DOL5, "QUAD:COL0:240:BMIN")
  field(DOL6, "QUAD:COL0:240:BMIN")
  field(LNK1, "QUAD:COL0:240:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:240:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:240:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:240:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:240:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:240:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:240:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:240:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:240:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:240:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:240:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:240:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:240:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:240:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:240:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:240:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:240:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:240:EDES NPP MS")
  field(INPB, "QUAD:COL0:240:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:260:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:260:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:260:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:260:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:260:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:260:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:260:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:260:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:260:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:260:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:260:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:260:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:260:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:260:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:260:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:260:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:260:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:260:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:260:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:260:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:260:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:260:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:260:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:260:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:260:BMAX")
  field(DOL2, "QUAD:COL0:260:BMAX")
  field(DOL3, "QUAD:COL0:260:BMAX")
  field(DOL4, "QUAD:COL0:260:BMIN")
  field(DOL5, "QUAD:COL0:260:BMIN")
  field(DOL6, "QUAD:COL0:260:BMIN")
  field(LNK1, "QUAD:COL0:260:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:260:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:260:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:260:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:260:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:260:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:260:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:260:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:260:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:260:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:260:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:260:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:260:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:260:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:260:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:260:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:260:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:260:EDES NPP MS")
  field(INPB, "QUAD:COL0:260:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:280:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:280:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:280:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:280:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:280:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:280:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:280:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:280:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:280:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:280:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:280:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:280:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:280:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:280:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:280:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:280:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:280:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:280:BMAX")
  field(DOL2, "QUAD:COL0:280:BMAX")
  field(DOL3, "QUAD:COL0:280:BMAX")
  field(DOL4, "QUAD:COL0:280:BMIN")
  field(DOL5, "QUAD:COL0:280:BMIN")
  field(DOL6, "QUAD:COL0:280:BMIN")
  field(LNK1, "QUAD:COL0:280:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:280:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:280:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:280:EDES NPP MS")
  field(INPB, "QUAD:COL0:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:320:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:320:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:320:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:320:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:320:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:320:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:320:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:320:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:320:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:320:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:320:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:320:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:320:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:320:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:320:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:320:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:320:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:320:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:320:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:320:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:320:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:320:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:320:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:320:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:320:BMAX")
  field(DOL2, "QUAD:COL0:320:BMAX")
  field(DOL3, "QUAD:COL0:320:BMAX")
  field(DOL4, "QUAD:COL0:320:BMIN")
  field(DOL5, "QUAD:COL0:320:BMIN")
  field(DOL6, "QUAD:COL0:320:BMIN")
  field(LNK1, "QUAD:COL0:320:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:320:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:320:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:320:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:320:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:320:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:320:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:320:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:320:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:320:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:320:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:320:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:320:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:320:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:320:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:320:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:320:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:320:EDES NPP MS")
  field(INPB, "QUAD:COL0:320:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:400:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:400:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:400:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:400:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:400:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:400:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:400:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:400:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:400:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:400:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:400:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:400:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:400:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:400:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:400:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:400:BMAX")
  field(DOL2, "QUAD:COL0:400:BMAX")
  field(DOL3, "QUAD:COL0:400:BMAX")
  field(DOL4, "QUAD:COL0:400:BMIN")
  field(DOL5, "QUAD:COL0:400:BMIN")
  field(DOL6, "QUAD:COL0:400:BMIN")
  field(LNK1, "QUAD:COL0:400:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:400:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:400:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:400:EDES NPP MS")
  field(INPB, "QUAD:COL0:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:480:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:480:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:480:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:480:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:480:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:480:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:480:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:480:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:480:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:480:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:480:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:480:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:480:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:480:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:480:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:480:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:480:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:480:BMAX")
  field(DOL2, "QUAD:COL0:480:BMAX")
  field(DOL3, "QUAD:COL0:480:BMAX")
  field(DOL4, "QUAD:COL0:480:BMIN")
  field(DOL5, "QUAD:COL0:480:BMIN")
  field(DOL6, "QUAD:COL0:480:BMIN")
  field(LNK1, "QUAD:COL0:480:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:480:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:480:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:480:EDES NPP MS")
  field(INPB, "QUAD:COL0:480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:560:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:560:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:560:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:560:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:560:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:560:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:560:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:560:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:560:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:560:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:560:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:560:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:560:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:560:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:560:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:560:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:560:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:560:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:560:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:560:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:560:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:560:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:560:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:560:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:560:BMAX")
  field(DOL2, "QUAD:COL0:560:BMAX")
  field(DOL3, "QUAD:COL0:560:BMAX")
  field(DOL4, "QUAD:COL0:560:BMIN")
  field(DOL5, "QUAD:COL0:560:BMIN")
  field(DOL6, "QUAD:COL0:560:BMIN")
  field(LNK1, "QUAD:COL0:560:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:560:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:560:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:560:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:560:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:560:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:560:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:560:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:560:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:560:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:560:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:560:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:560:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:560:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:560:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:560:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:560:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:560:EDES NPP MS")
  field(INPB, "QUAD:COL0:560:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:640:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:640:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:640:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:640:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:640:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:640:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:640:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:640:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:640:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:640:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:640:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:640:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:640:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:640:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:640:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:640:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:640:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:640:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:640:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:640:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:640:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:640:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:640:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:640:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:640:BMAX")
  field(DOL2, "QUAD:COL0:640:BMAX")
  field(DOL3, "QUAD:COL0:640:BMAX")
  field(DOL4, "QUAD:COL0:640:BMIN")
  field(DOL5, "QUAD:COL0:640:BMIN")
  field(DOL6, "QUAD:COL0:640:BMIN")
  field(LNK1, "QUAD:COL0:640:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:640:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:640:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:640:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:640:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:640:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:640:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:640:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:640:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:640:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:640:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:640:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:640:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:640:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:640:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:640:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:640:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:640:EDES NPP MS")
  field(INPB, "QUAD:COL0:640:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:720:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:720:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:720:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:720:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:720:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:720:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:720:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:720:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:720:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:720:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:720:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:720:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:720:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:720:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:720:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:720:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:720:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:720:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:720:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:720:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:720:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:720:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:720:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:720:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:720:BMAX")
  field(DOL2, "QUAD:COL0:720:BMAX")
  field(DOL3, "QUAD:COL0:720:BMAX")
  field(DOL4, "QUAD:COL0:720:BMIN")
  field(DOL5, "QUAD:COL0:720:BMIN")
  field(DOL6, "QUAD:COL0:720:BMIN")
  field(LNK1, "QUAD:COL0:720:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:720:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:720:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:720:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:720:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:720:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:720:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:720:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:720:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:720:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:720:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:720:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:720:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:720:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:720:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:720:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:720:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:720:EDES NPP MS")
  field(INPB, "QUAD:COL0:720:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:800:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:800:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:800:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:800:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:800:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:800:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:800:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:800:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:800:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:800:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:800:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:800:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:800:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:800:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:800:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:800:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:800:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:800:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:800:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:800:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:800:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:800:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:800:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:800:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:800:BMAX")
  field(DOL2, "QUAD:COL0:800:BMAX")
  field(DOL3, "QUAD:COL0:800:BMAX")
  field(DOL4, "QUAD:COL0:800:BMIN")
  field(DOL5, "QUAD:COL0:800:BMIN")
  field(DOL6, "QUAD:COL0:800:BMIN")
  field(LNK1, "QUAD:COL0:800:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:800:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:800:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:800:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:800:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:800:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:800:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:800:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:800:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:800:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:800:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:800:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:800:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:800:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:800:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:800:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:800:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:800:EDES NPP MS")
  field(INPB, "QUAD:COL0:800:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:880:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:880:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:880:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:880:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:880:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:880:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:880:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:880:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:880:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:880:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:880:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:880:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:880:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:880:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:880:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:880:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:880:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:880:BMAX")
  field(DOL2, "QUAD:COL0:880:BMAX")
  field(DOL3, "QUAD:COL0:880:BMAX")
  field(DOL4, "QUAD:COL0:880:BMIN")
  field(DOL5, "QUAD:COL0:880:BMIN")
  field(DOL6, "QUAD:COL0:880:BMIN")
  field(LNK1, "QUAD:COL0:880:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:880:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:880:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:880:EDES NPP MS")
  field(INPB, "QUAD:COL0:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL0:940:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL0:940:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL0:940:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL0:940:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL0:940:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL0:940:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL0:940:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL0:940:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL0:940:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL0:940:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL0:940:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL0:940:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL0:940:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL0:940:EDES.PROC PP")
    field(LNK2, "QUAD:COL0:940:EACT.PROC PP")
    field(LNK3, "QUAD:COL0:940:EERR.DISA PP")
    field(LNK4, "QUAD:COL0:940:ECON.PROC PP")
    field(LNK5, "QUAD:COL0:940:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL0:940:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL0:940:BLEM.PROC PP")
    field(LNK8, "QUAD:COL0:940:BMOD.PROC PP")
    field(LNK9, "QUAD:COL0:940:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL0:940:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL0:940:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL0:940:BMAX")
  field(DOL2, "QUAD:COL0:940:BMAX")
  field(DOL3, "QUAD:COL0:940:BMAX")
  field(DOL4, "QUAD:COL0:940:BMIN")
  field(DOL5, "QUAD:COL0:940:BMIN")
  field(DOL6, "QUAD:COL0:940:BMIN")
  field(LNK1, "QUAD:COL0:940:BMAGX.HOPR")
  field(LNK2, "QUAD:COL0:940:BMAGY.HOPR")
  field(LNK3, "QUAD:COL0:940:BLEM.HOPR")
  field(LNK4, "QUAD:COL0:940:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL0:940:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL0:940:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:940:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL0:940:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL0:940:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL0:940:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL0:940:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:940:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:940:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:940:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL0:940:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL0:940:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL0:940:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL0:940:EDES NPP MS")
  field(INPB, "QUAD:COL0:940:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL0:235:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL0:235:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL0:235:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL0:235:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL0:235:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL0:235:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL0:235:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL0:235:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL0:235:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL0:235:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL0:235:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL0:235:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL0:235:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL0:235:EDES.PROC PP")
    field(LNK2, "XCOR:COL0:235:EACT.PROC PP")
    field(LNK3, "XCOR:COL0:235:EERR.DISA PP")
    field(LNK4, "XCOR:COL0:235:ECON.PROC PP")
    field(LNK5, "XCOR:COL0:235:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL0:235:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL0:235:BLEM.PROC PP")
    field(LNK8, "XCOR:COL0:235:BMOD.PROC PP")
    field(LNK9, "XCOR:COL0:235:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL0:235:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL0:235:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL0:235:BMAX")
  field(DOL2, "XCOR:COL0:235:BMAX")
  field(DOL3, "XCOR:COL0:235:BMAX")
  field(DOL4, "XCOR:COL0:235:BMIN")
  field(DOL5, "XCOR:COL0:235:BMIN")
  field(DOL6, "XCOR:COL0:235:BMIN")
  field(LNK1, "XCOR:COL0:235:BMAGX.HOPR")
  field(LNK2, "XCOR:COL0:235:BMAGY.HOPR")
  field(LNK3, "XCOR:COL0:235:BLEM.HOPR")
  field(LNK4, "XCOR:COL0:235:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL0:235:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL0:235:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:235:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:235:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL0:235:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL0:235:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL0:235:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:235:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:235:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:235:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:235:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:235:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL0:235:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL0:235:EDES NPP MS")
  field(INPB, "XCOR:COL0:235:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL0:328:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL0:328:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL0:328:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL0:328:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL0:328:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL0:328:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL0:328:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL0:328:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL0:328:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL0:328:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL0:328:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL0:328:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL0:328:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL0:328:EDES.PROC PP")
    field(LNK2, "XCOR:COL0:328:EACT.PROC PP")
    field(LNK3, "XCOR:COL0:328:EERR.DISA PP")
    field(LNK4, "XCOR:COL0:328:ECON.PROC PP")
    field(LNK5, "XCOR:COL0:328:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL0:328:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL0:328:BLEM.PROC PP")
    field(LNK8, "XCOR:COL0:328:BMOD.PROC PP")
    field(LNK9, "XCOR:COL0:328:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL0:328:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL0:328:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL0:328:BMAX")
  field(DOL2, "XCOR:COL0:328:BMAX")
  field(DOL3, "XCOR:COL0:328:BMAX")
  field(DOL4, "XCOR:COL0:328:BMIN")
  field(DOL5, "XCOR:COL0:328:BMIN")
  field(DOL6, "XCOR:COL0:328:BMIN")
  field(LNK1, "XCOR:COL0:328:BMAGX.HOPR")
  field(LNK2, "XCOR:COL0:328:BMAGY.HOPR")
  field(LNK3, "XCOR:COL0:328:BLEM.HOPR")
  field(LNK4, "XCOR:COL0:328:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL0:328:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL0:328:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:328:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:328:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL0:328:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL0:328:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL0:328:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:328:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:328:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:328:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:328:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:328:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL0:328:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL0:328:EDES NPP MS")
  field(INPB, "XCOR:COL0:328:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL0:488:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL0:488:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL0:488:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL0:488:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL0:488:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL0:488:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL0:488:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL0:488:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL0:488:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL0:488:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL0:488:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL0:488:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL0:488:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL0:488:EDES.PROC PP")
    field(LNK2, "XCOR:COL0:488:EACT.PROC PP")
    field(LNK3, "XCOR:COL0:488:EERR.DISA PP")
    field(LNK4, "XCOR:COL0:488:ECON.PROC PP")
    field(LNK5, "XCOR:COL0:488:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL0:488:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL0:488:BLEM.PROC PP")
    field(LNK8, "XCOR:COL0:488:BMOD.PROC PP")
    field(LNK9, "XCOR:COL0:488:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL0:488:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL0:488:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL0:488:BMAX")
  field(DOL2, "XCOR:COL0:488:BMAX")
  field(DOL3, "XCOR:COL0:488:BMAX")
  field(DOL4, "XCOR:COL0:488:BMIN")
  field(DOL5, "XCOR:COL0:488:BMIN")
  field(DOL6, "XCOR:COL0:488:BMIN")
  field(LNK1, "XCOR:COL0:488:BMAGX.HOPR")
  field(LNK2, "XCOR:COL0:488:BMAGY.HOPR")
  field(LNK3, "XCOR:COL0:488:BLEM.HOPR")
  field(LNK4, "XCOR:COL0:488:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL0:488:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL0:488:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:488:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:488:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL0:488:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL0:488:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL0:488:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:488:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:488:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:488:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:488:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:488:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL0:488:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL0:488:EDES NPP MS")
  field(INPB, "XCOR:COL0:488:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL0:648:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL0:648:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL0:648:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL0:648:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL0:648:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL0:648:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL0:648:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL0:648:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL0:648:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL0:648:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL0:648:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL0:648:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL0:648:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL0:648:EDES.PROC PP")
    field(LNK2, "XCOR:COL0:648:EACT.PROC PP")
    field(LNK3, "XCOR:COL0:648:EERR.DISA PP")
    field(LNK4, "XCOR:COL0:648:ECON.PROC PP")
    field(LNK5, "XCOR:COL0:648:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL0:648:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL0:648:BLEM.PROC PP")
    field(LNK8, "XCOR:COL0:648:BMOD.PROC PP")
    field(LNK9, "XCOR:COL0:648:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL0:648:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL0:648:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL0:648:BMAX")
  field(DOL2, "XCOR:COL0:648:BMAX")
  field(DOL3, "XCOR:COL0:648:BMAX")
  field(DOL4, "XCOR:COL0:648:BMIN")
  field(DOL5, "XCOR:COL0:648:BMIN")
  field(DOL6, "XCOR:COL0:648:BMIN")
  field(LNK1, "XCOR:COL0:648:BMAGX.HOPR")
  field(LNK2, "XCOR:COL0:648:BMAGY.HOPR")
  field(LNK3, "XCOR:COL0:648:BLEM.HOPR")
  field(LNK4, "XCOR:COL0:648:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL0:648:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL0:648:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:648:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:648:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL0:648:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL0:648:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL0:648:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:648:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:648:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:648:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:648:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:648:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL0:648:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL0:648:EDES NPP MS")
  field(INPB, "XCOR:COL0:648:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL0:808:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL0:808:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL0:808:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL0:808:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL0:808:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL0:808:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL0:808:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL0:808:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL0:808:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL0:808:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL0:808:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL0:808:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL0:808:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL0:808:EDES.PROC PP")
    field(LNK2, "XCOR:COL0:808:EACT.PROC PP")
    field(LNK3, "XCOR:COL0:808:EERR.DISA PP")
    field(LNK4, "XCOR:COL0:808:ECON.PROC PP")
    field(LNK5, "XCOR:COL0:808:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL0:808:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL0:808:BLEM.PROC PP")
    field(LNK8, "XCOR:COL0:808:BMOD.PROC PP")
    field(LNK9, "XCOR:COL0:808:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL0:808:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL0:808:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL0:808:BMAX")
  field(DOL2, "XCOR:COL0:808:BMAX")
  field(DOL3, "XCOR:COL0:808:BMAX")
  field(DOL4, "XCOR:COL0:808:BMIN")
  field(DOL5, "XCOR:COL0:808:BMIN")
  field(DOL6, "XCOR:COL0:808:BMIN")
  field(LNK1, "XCOR:COL0:808:BMAGX.HOPR")
  field(LNK2, "XCOR:COL0:808:BMAGY.HOPR")
  field(LNK3, "XCOR:COL0:808:BLEM.HOPR")
  field(LNK4, "XCOR:COL0:808:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL0:808:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL0:808:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:808:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:808:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL0:808:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL0:808:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL0:808:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:808:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:808:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:808:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:808:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:808:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL0:808:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL0:808:EDES NPP MS")
  field(INPB, "XCOR:COL0:808:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL0:932:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL0:932:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL0:932:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL0:932:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL0:932:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL0:932:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL0:932:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL0:932:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL0:932:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL0:932:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL0:932:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL0:932:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL0:932:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL0:932:EDES.PROC PP")
    field(LNK2, "XCOR:COL0:932:EACT.PROC PP")
    field(LNK3, "XCOR:COL0:932:EERR.DISA PP")
    field(LNK4, "XCOR:COL0:932:ECON.PROC PP")
    field(LNK5, "XCOR:COL0:932:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL0:932:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL0:932:BLEM.PROC PP")
    field(LNK8, "XCOR:COL0:932:BMOD.PROC PP")
    field(LNK9, "XCOR:COL0:932:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL0:932:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL0:932:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL0:932:BMAX")
  field(DOL2, "XCOR:COL0:932:BMAX")
  field(DOL3, "XCOR:COL0:932:BMAX")
  field(DOL4, "XCOR:COL0:932:BMIN")
  field(DOL5, "XCOR:COL0:932:BMIN")
  field(DOL6, "XCOR:COL0:932:BMIN")
  field(LNK1, "XCOR:COL0:932:BMAGX.HOPR")
  field(LNK2, "XCOR:COL0:932:BMAGY.HOPR")
  field(LNK3, "XCOR:COL0:932:BLEM.HOPR")
  field(LNK4, "XCOR:COL0:932:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL0:932:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL0:932:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:932:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL0:932:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL0:932:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL0:932:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL0:932:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:932:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:932:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:932:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL0:932:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL0:932:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL0:932:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL0:932:EDES NPP MS")
  field(INPB, "XCOR:COL0:932:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL0:235:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL0:235:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL0:235:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL0:235:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL0:235:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL0:235:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL0:235:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL0:235:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL0:235:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL0:235:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL0:235:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL0:235:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL0:235:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL0:235:EDES.PROC PP")
    field(LNK2, "YCOR:COL0:235:EACT.PROC PP")
    field(LNK3, "YCOR:COL0:235:EERR.DISA PP")
    field(LNK4, "YCOR:COL0:235:ECON.PROC PP")
    field(LNK5, "YCOR:COL0:235:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL0:235:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL0:235:BLEM.PROC PP")
    field(LNK8, "YCOR:COL0:235:BMOD.PROC PP")
    field(LNK9, "YCOR:COL0:235:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL0:235:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL0:235:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL0:235:BMAX")
  field(DOL2, "YCOR:COL0:235:BMAX")
  field(DOL3, "YCOR:COL0:235:BMAX")
  field(DOL4, "YCOR:COL0:235:BMIN")
  field(DOL5, "YCOR:COL0:235:BMIN")
  field(DOL6, "YCOR:COL0:235:BMIN")
  field(LNK1, "YCOR:COL0:235:BMAGX.HOPR")
  field(LNK2, "YCOR:COL0:235:BMAGY.HOPR")
  field(LNK3, "YCOR:COL0:235:BLEM.HOPR")
  field(LNK4, "YCOR:COL0:235:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL0:235:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL0:235:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:235:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:235:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL0:235:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL0:235:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL0:235:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:235:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:235:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:235:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:235:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:235:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL0:235:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL0:235:EDES NPP MS")
  field(INPB, "YCOR:COL0:235:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL0:289:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL0:289:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL0:289:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL0:289:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL0:289:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL0:289:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL0:289:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL0:289:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL0:289:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL0:289:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL0:289:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL0:289:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL0:289:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL0:289:EDES.PROC PP")
    field(LNK2, "YCOR:COL0:289:EACT.PROC PP")
    field(LNK3, "YCOR:COL0:289:EERR.DISA PP")
    field(LNK4, "YCOR:COL0:289:ECON.PROC PP")
    field(LNK5, "YCOR:COL0:289:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL0:289:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL0:289:BLEM.PROC PP")
    field(LNK8, "YCOR:COL0:289:BMOD.PROC PP")
    field(LNK9, "YCOR:COL0:289:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL0:289:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL0:289:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL0:289:BMAX")
  field(DOL2, "YCOR:COL0:289:BMAX")
  field(DOL3, "YCOR:COL0:289:BMAX")
  field(DOL4, "YCOR:COL0:289:BMIN")
  field(DOL5, "YCOR:COL0:289:BMIN")
  field(DOL6, "YCOR:COL0:289:BMIN")
  field(LNK1, "YCOR:COL0:289:BMAGX.HOPR")
  field(LNK2, "YCOR:COL0:289:BMAGY.HOPR")
  field(LNK3, "YCOR:COL0:289:BLEM.HOPR")
  field(LNK4, "YCOR:COL0:289:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL0:289:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL0:289:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:289:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:289:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL0:289:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL0:289:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL0:289:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:289:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:289:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:289:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:289:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:289:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL0:289:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL0:289:EDES NPP MS")
  field(INPB, "YCOR:COL0:289:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL0:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL0:409:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL0:409:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL0:409:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL0:409:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL0:409:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL0:409:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL0:409:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL0:409:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL0:409:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL0:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL0:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL0:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL0:409:EDES.PROC PP")
    field(LNK2, "YCOR:COL0:409:EACT.PROC PP")
    field(LNK3, "YCOR:COL0:409:EERR.DISA PP")
    field(LNK4, "YCOR:COL0:409:ECON.PROC PP")
    field(LNK5, "YCOR:COL0:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL0:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL0:409:BLEM.PROC PP")
    field(LNK8, "YCOR:COL0:409:BMOD.PROC PP")
    field(LNK9, "YCOR:COL0:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL0:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL0:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL0:409:BMAX")
  field(DOL2, "YCOR:COL0:409:BMAX")
  field(DOL3, "YCOR:COL0:409:BMAX")
  field(DOL4, "YCOR:COL0:409:BMIN")
  field(DOL5, "YCOR:COL0:409:BMIN")
  field(DOL6, "YCOR:COL0:409:BMIN")
  field(LNK1, "YCOR:COL0:409:BMAGX.HOPR")
  field(LNK2, "YCOR:COL0:409:BMAGY.HOPR")
  field(LNK3, "YCOR:COL0:409:BLEM.HOPR")
  field(LNK4, "YCOR:COL0:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL0:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL0:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL0:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL0:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL0:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL0:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL0:409:EDES NPP MS")
  field(INPB, "YCOR:COL0:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL0:569:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL0:569:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL0:569:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL0:569:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL0:569:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL0:569:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL0:569:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL0:569:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL0:569:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL0:569:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL0:569:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL0:569:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL0:569:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL0:569:EDES.PROC PP")
    field(LNK2, "YCOR:COL0:569:EACT.PROC PP")
    field(LNK3, "YCOR:COL0:569:EERR.DISA PP")
    field(LNK4, "YCOR:COL0:569:ECON.PROC PP")
    field(LNK5, "YCOR:COL0:569:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL0:569:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL0:569:BLEM.PROC PP")
    field(LNK8, "YCOR:COL0:569:BMOD.PROC PP")
    field(LNK9, "YCOR:COL0:569:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL0:569:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL0:569:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL0:569:BMAX")
  field(DOL2, "YCOR:COL0:569:BMAX")
  field(DOL3, "YCOR:COL0:569:BMAX")
  field(DOL4, "YCOR:COL0:569:BMIN")
  field(DOL5, "YCOR:COL0:569:BMIN")
  field(DOL6, "YCOR:COL0:569:BMIN")
  field(LNK1, "YCOR:COL0:569:BMAGX.HOPR")
  field(LNK2, "YCOR:COL0:569:BMAGY.HOPR")
  field(LNK3, "YCOR:COL0:569:BLEM.HOPR")
  field(LNK4, "YCOR:COL0:569:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL0:569:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL0:569:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:569:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:569:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL0:569:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL0:569:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL0:569:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:569:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:569:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:569:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:569:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:569:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL0:569:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL0:569:EDES NPP MS")
  field(INPB, "YCOR:COL0:569:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL0:729:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL0:729:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL0:729:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL0:729:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL0:729:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL0:729:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL0:729:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL0:729:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL0:729:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL0:729:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL0:729:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL0:729:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL0:729:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL0:729:EDES.PROC PP")
    field(LNK2, "YCOR:COL0:729:EACT.PROC PP")
    field(LNK3, "YCOR:COL0:729:EERR.DISA PP")
    field(LNK4, "YCOR:COL0:729:ECON.PROC PP")
    field(LNK5, "YCOR:COL0:729:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL0:729:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL0:729:BLEM.PROC PP")
    field(LNK8, "YCOR:COL0:729:BMOD.PROC PP")
    field(LNK9, "YCOR:COL0:729:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL0:729:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL0:729:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL0:729:BMAX")
  field(DOL2, "YCOR:COL0:729:BMAX")
  field(DOL3, "YCOR:COL0:729:BMAX")
  field(DOL4, "YCOR:COL0:729:BMIN")
  field(DOL5, "YCOR:COL0:729:BMIN")
  field(DOL6, "YCOR:COL0:729:BMIN")
  field(LNK1, "YCOR:COL0:729:BMAGX.HOPR")
  field(LNK2, "YCOR:COL0:729:BMAGY.HOPR")
  field(LNK3, "YCOR:COL0:729:BLEM.HOPR")
  field(LNK4, "YCOR:COL0:729:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL0:729:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL0:729:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:729:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:729:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL0:729:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL0:729:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL0:729:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:729:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:729:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:729:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:729:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:729:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL0:729:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL0:729:EDES NPP MS")
  field(INPB, "YCOR:COL0:729:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL0:889:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL0:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL0:889:FUNC CA PP")
  field(DOL2, "MGNT:COL0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL0:889:FUNC CA PP")
  field(DOL3, "MGNT:COL0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL0:889:FUNC CA PP")
  field(DOL4, "MGNT:COL0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL0:889:FUNC CA PP")
  field(DOL5, "MGNT:COL0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL0:889:FUNC CA PP")
  field(DOL6, "MGNT:COL0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL0:889:FUNC CA PP")
  field(DOL7, "MGNT:COL0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL0:889:FUNC CA PP")
  field(DOL8, "MGNT:COL0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL0:889:FUNC CA PP")
  field(DOL9, "MGNT:COL0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL0:889:FUNC CA PP")
  field(DOLA, "MGNT:COL0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL0:889:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL0:889:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL0:889:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL0:889:EDES.PROC PP")
    field(LNK2, "YCOR:COL0:889:EACT.PROC PP")
    field(LNK3, "YCOR:COL0:889:EERR.DISA PP")
    field(LNK4, "YCOR:COL0:889:ECON.PROC PP")
    field(LNK5, "YCOR:COL0:889:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL0:889:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL0:889:BLEM.PROC PP")
    field(LNK8, "YCOR:COL0:889:BMOD.PROC PP")
    field(LNK9, "YCOR:COL0:889:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL0:889:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL0:889:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL0:889:BMAX")
  field(DOL2, "YCOR:COL0:889:BMAX")
  field(DOL3, "YCOR:COL0:889:BMAX")
  field(DOL4, "YCOR:COL0:889:BMIN")
  field(DOL5, "YCOR:COL0:889:BMIN")
  field(DOL6, "YCOR:COL0:889:BMIN")
  field(LNK1, "YCOR:COL0:889:BMAGX.HOPR")
  field(LNK2, "YCOR:COL0:889:BMAGY.HOPR")
  field(LNK3, "YCOR:COL0:889:BLEM.HOPR")
  field(LNK4, "YCOR:COL0:889:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL0:889:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL0:889:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:889:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL0:889:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL0:889:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL0:889:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL0:889:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:889:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:889:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:889:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL0:889:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL0:889:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL0:889:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL0:889:EDES NPP MS")
  field(INPB, "YCOR:COL0:889:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DIAG0:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DIAG0:110:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DIAG0:110:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DIAG0:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DIAG0:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DIAG0:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DIAG0:110:EDES.PROC PP")
    field(LNK2, "KICK:DIAG0:110:EACT.PROC PP")
    field(LNK3, "KICK:DIAG0:110:EERR.DISA PP")
    field(LNK4, "KICK:DIAG0:110:ECON.PROC PP")
    field(LNK5, "KICK:DIAG0:110:BMAGX.PROC PP")
    field(LNK6, "KICK:DIAG0:110:BMAGY.PROC PP")
    field(LNK7, "KICK:DIAG0:110:BLEM.PROC PP")
    field(LNK8, "KICK:DIAG0:110:BMOD.PROC PP")
    field(LNK9, "KICK:DIAG0:110:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DIAG0:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DIAG0:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DIAG0:110:BMAX")
  field(DOL2, "KICK:DIAG0:110:BMAX")
  field(DOL3, "KICK:DIAG0:110:BMAX")
  field(DOL4, "KICK:DIAG0:110:BMIN")
  field(DOL5, "KICK:DIAG0:110:BMIN")
  field(DOL6, "KICK:DIAG0:110:BMIN")
  field(LNK1, "KICK:DIAG0:110:BMAGX.HOPR")
  field(LNK2, "KICK:DIAG0:110:BMAGY.HOPR")
  field(LNK3, "KICK:DIAG0:110:BLEM.HOPR")
  field(LNK4, "KICK:DIAG0:110:BMAGX.LOPR PP")
  field(LNK5, "KICK:DIAG0:110:BMAGY.LOPR PP")
  field(LNK6, "KICK:DIAG0:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DIAG0:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DIAG0:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DIAG0:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DIAG0:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DIAG0:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DIAG0:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DIAG0:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:DIAG0:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DIAG0:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:DIAG0:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DIAG0:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DIAG0:110:EDES NPP MS")
  field(INPB, "KICK:DIAG0:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DIAG0:155:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DIAG0:155:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DIAG0:155:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DIAG0:155:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DIAG0:155:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DIAG0:155:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DIAG0:155:EDES.PROC PP")
    field(LNK2, "BEND:DIAG0:155:EACT.PROC PP")
    field(LNK3, "BEND:DIAG0:155:EERR.DISA PP")
    field(LNK4, "BEND:DIAG0:155:ECON.PROC PP")
    field(LNK5, "BEND:DIAG0:155:BMAGX.PROC PP")
    field(LNK6, "BEND:DIAG0:155:BMAGY.PROC PP")
    field(LNK7, "BEND:DIAG0:155:BLEM.PROC PP")
    field(LNK8, "BEND:DIAG0:155:BMOD.PROC PP")
    field(LNK9, "BEND:DIAG0:155:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DIAG0:155:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DIAG0:155:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DIAG0:155:BMAX")
  field(DOL2, "BEND:DIAG0:155:BMAX")
  field(DOL3, "BEND:DIAG0:155:BMAX")
  field(DOL4, "BEND:DIAG0:155:BMIN")
  field(DOL5, "BEND:DIAG0:155:BMIN")
  field(DOL6, "BEND:DIAG0:155:BMIN")
  field(LNK1, "BEND:DIAG0:155:BMAGX.HOPR")
  field(LNK2, "BEND:DIAG0:155:BMAGY.HOPR")
  field(LNK3, "BEND:DIAG0:155:BLEM.HOPR")
  field(LNK4, "BEND:DIAG0:155:BMAGX.LOPR PP")
  field(LNK5, "BEND:DIAG0:155:BMAGY.LOPR PP")
  field(LNK6, "BEND:DIAG0:155:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DIAG0:155:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DIAG0:155:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DIAG0:155:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DIAG0:155:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DIAG0:155:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:155:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:155:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DIAG0:155:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:155:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DIAG0:155:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DIAG0:155:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DIAG0:155:EDES NPP MS")
  field(INPB, "BEND:DIAG0:155:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DIAG0:510:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DIAG0:510:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DIAG0:510:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DIAG0:510:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DIAG0:510:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DIAG0:510:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DIAG0:510:EDES.PROC PP")
    field(LNK2, "BEND:DIAG0:510:EACT.PROC PP")
    field(LNK3, "BEND:DIAG0:510:EERR.DISA PP")
    field(LNK4, "BEND:DIAG0:510:ECON.PROC PP")
    field(LNK5, "BEND:DIAG0:510:BMAGX.PROC PP")
    field(LNK6, "BEND:DIAG0:510:BMAGY.PROC PP")
    field(LNK7, "BEND:DIAG0:510:BLEM.PROC PP")
    field(LNK8, "BEND:DIAG0:510:BMOD.PROC PP")
    field(LNK9, "BEND:DIAG0:510:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DIAG0:510:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DIAG0:510:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DIAG0:510:BMAX")
  field(DOL2, "BEND:DIAG0:510:BMAX")
  field(DOL3, "BEND:DIAG0:510:BMAX")
  field(DOL4, "BEND:DIAG0:510:BMIN")
  field(DOL5, "BEND:DIAG0:510:BMIN")
  field(DOL6, "BEND:DIAG0:510:BMIN")
  field(LNK1, "BEND:DIAG0:510:BMAGX.HOPR")
  field(LNK2, "BEND:DIAG0:510:BMAGY.HOPR")
  field(LNK3, "BEND:DIAG0:510:BLEM.HOPR")
  field(LNK4, "BEND:DIAG0:510:BMAGX.LOPR PP")
  field(LNK5, "BEND:DIAG0:510:BMAGY.LOPR PP")
  field(LNK6, "BEND:DIAG0:510:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DIAG0:510:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DIAG0:510:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DIAG0:510:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DIAG0:510:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DIAG0:510:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:510:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:510:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DIAG0:510:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:510:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DIAG0:510:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DIAG0:510:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DIAG0:510:EDES NPP MS")
  field(INPB, "BEND:DIAG0:510:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DIAG0:260:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DIAG0:260:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DIAG0:260:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DIAG0:260:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DIAG0:260:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DIAG0:260:EDES.PROC PP")
    field(LNK2, "BTRM:DIAG0:260:EACT.PROC PP")
    field(LNK3, "BTRM:DIAG0:260:EERR.DISA PP")
    field(LNK4, "BTRM:DIAG0:260:ECON.PROC PP")
    field(LNK5, "BTRM:DIAG0:260:BMAGX.PROC PP")
    field(LNK6, "BTRM:DIAG0:260:BMAGY.PROC PP")
    field(LNK7, "BTRM:DIAG0:260:BLEM.PROC PP")
    field(LNK8, "BTRM:DIAG0:260:BMOD.PROC PP")
    field(LNK9, "BTRM:DIAG0:260:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DIAG0:260:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DIAG0:260:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DIAG0:260:BMAX")
  field(DOL2, "BTRM:DIAG0:260:BMAX")
  field(DOL3, "BTRM:DIAG0:260:BMAX")
  field(DOL4, "BTRM:DIAG0:260:BMIN")
  field(DOL5, "BTRM:DIAG0:260:BMIN")
  field(DOL6, "BTRM:DIAG0:260:BMIN")
  field(LNK1, "BTRM:DIAG0:260:BMAGX.HOPR")
  field(LNK2, "BTRM:DIAG0:260:BMAGY.HOPR")
  field(LNK3, "BTRM:DIAG0:260:BLEM.HOPR")
  field(LNK4, "BTRM:DIAG0:260:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DIAG0:260:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DIAG0:260:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DIAG0:260:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DIAG0:260:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DIAG0:260:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DIAG0:260:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Atrim")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DIAG0:260:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DIAG0:260:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DIAG0:260:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DIAG0:260:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DIAG0:260:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DIAG0:260:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DIAG0:260:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DIAG0:260:EDES NPP MS")
  field(INPB, "BTRM:DIAG0:260:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:190:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:190:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:190:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:190:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:190:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:190:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:190:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:190:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:190:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:190:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:190:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:190:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:190:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:190:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:190:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:190:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:190:BMAX")
  field(DOL2, "QUAD:DIAG0:190:BMAX")
  field(DOL3, "QUAD:DIAG0:190:BMAX")
  field(DOL4, "QUAD:DIAG0:190:BMIN")
  field(DOL5, "QUAD:DIAG0:190:BMIN")
  field(DOL6, "QUAD:DIAG0:190:BMIN")
  field(LNK1, "QUAD:DIAG0:190:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:190:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:190:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:190:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:190:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:190:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:190:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:190:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:190:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:190:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:190:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:190:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:190:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:190:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:190:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:190:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:190:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:190:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:190:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:210:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:210:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:210:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:210:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:210:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:210:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:210:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:210:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:210:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:210:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:210:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:210:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:210:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:210:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:210:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:210:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:210:BMAX")
  field(DOL2, "QUAD:DIAG0:210:BMAX")
  field(DOL3, "QUAD:DIAG0:210:BMAX")
  field(DOL4, "QUAD:DIAG0:210:BMIN")
  field(DOL5, "QUAD:DIAG0:210:BMIN")
  field(DOL6, "QUAD:DIAG0:210:BMIN")
  field(LNK1, "QUAD:DIAG0:210:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:210:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:210:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:210:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:210:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:210:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:210:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:210:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:210:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:210:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:210:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:210:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:210:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:210:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:210:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:210:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:210:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:210:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:210:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:230:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:230:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:230:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:230:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:230:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:230:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:230:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:230:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:230:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:230:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:230:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:230:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:230:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:230:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:230:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:230:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:230:BMAX")
  field(DOL2, "QUAD:DIAG0:230:BMAX")
  field(DOL3, "QUAD:DIAG0:230:BMAX")
  field(DOL4, "QUAD:DIAG0:230:BMIN")
  field(DOL5, "QUAD:DIAG0:230:BMIN")
  field(DOL6, "QUAD:DIAG0:230:BMIN")
  field(LNK1, "QUAD:DIAG0:230:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:230:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:230:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:230:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:230:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:230:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:230:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:230:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:230:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:230:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:230:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:230:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:230:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:230:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:230:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:230:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:230:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:230:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:230:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:270:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:270:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:270:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:270:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:270:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:270:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:270:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:270:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:270:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:270:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:270:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:270:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:270:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:270:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:270:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:270:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:270:BMAX")
  field(DOL2, "QUAD:DIAG0:270:BMAX")
  field(DOL3, "QUAD:DIAG0:270:BMAX")
  field(DOL4, "QUAD:DIAG0:270:BMIN")
  field(DOL5, "QUAD:DIAG0:270:BMIN")
  field(DOL6, "QUAD:DIAG0:270:BMIN")
  field(LNK1, "QUAD:DIAG0:270:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:270:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:270:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:270:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:270:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:270:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:270:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:270:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:270:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:270:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:270:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:270:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:270:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:270:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:270:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:270:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:270:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:270:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:270:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:285:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:285:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:285:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:285:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:285:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:285:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:285:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:285:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:285:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:285:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:285:BMAX")
  field(DOL2, "QUAD:DIAG0:285:BMAX")
  field(DOL3, "QUAD:DIAG0:285:BMAX")
  field(DOL4, "QUAD:DIAG0:285:BMIN")
  field(DOL5, "QUAD:DIAG0:285:BMIN")
  field(DOL6, "QUAD:DIAG0:285:BMIN")
  field(LNK1, "QUAD:DIAG0:285:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:285:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:285:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:285:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:285:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:285:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:300:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:300:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:300:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:300:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:300:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:300:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:300:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:300:BMAX")
  field(DOL2, "QUAD:DIAG0:300:BMAX")
  field(DOL3, "QUAD:DIAG0:300:BMAX")
  field(DOL4, "QUAD:DIAG0:300:BMIN")
  field(DOL5, "QUAD:DIAG0:300:BMIN")
  field(DOL6, "QUAD:DIAG0:300:BMIN")
  field(LNK1, "QUAD:DIAG0:300:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:300:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:300:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:300:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:360:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:360:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:360:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:360:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:360:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:360:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:360:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:360:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:360:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:360:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:360:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:360:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:360:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:360:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:360:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:360:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:360:BMAX")
  field(DOL2, "QUAD:DIAG0:360:BMAX")
  field(DOL3, "QUAD:DIAG0:360:BMAX")
  field(DOL4, "QUAD:DIAG0:360:BMIN")
  field(DOL5, "QUAD:DIAG0:360:BMIN")
  field(DOL6, "QUAD:DIAG0:360:BMIN")
  field(LNK1, "QUAD:DIAG0:360:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:360:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:360:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:360:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:360:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:360:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:360:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:360:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:360:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:360:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:360:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:360:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:360:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:360:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:360:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:360:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:360:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:360:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:360:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:370:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:370:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:370:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:370:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:370:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:370:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:370:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:370:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:370:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:370:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:370:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:370:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:370:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:370:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:370:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:370:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:370:BMAX")
  field(DOL2, "QUAD:DIAG0:370:BMAX")
  field(DOL3, "QUAD:DIAG0:370:BMAX")
  field(DOL4, "QUAD:DIAG0:370:BMIN")
  field(DOL5, "QUAD:DIAG0:370:BMIN")
  field(DOL6, "QUAD:DIAG0:370:BMIN")
  field(LNK1, "QUAD:DIAG0:370:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:370:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:370:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:370:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:370:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:370:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:370:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:370:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:370:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:370:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:370:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:370:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:370:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:370:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:370:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:370:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:370:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:370:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:370:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:390:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:390:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:390:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:390:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:390:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:390:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:390:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:390:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:390:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:390:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:390:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:390:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:390:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:390:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:390:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:390:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:390:BMAX")
  field(DOL2, "QUAD:DIAG0:390:BMAX")
  field(DOL3, "QUAD:DIAG0:390:BMAX")
  field(DOL4, "QUAD:DIAG0:390:BMIN")
  field(DOL5, "QUAD:DIAG0:390:BMIN")
  field(DOL6, "QUAD:DIAG0:390:BMIN")
  field(LNK1, "QUAD:DIAG0:390:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:390:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:390:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:390:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:390:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:390:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:390:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:390:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:390:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:390:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:390:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:390:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:390:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:390:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:390:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:390:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:390:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:390:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:390:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:455:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:455:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:455:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:455:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:455:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:455:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:455:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:455:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:455:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:455:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:455:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:455:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:455:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:455:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:455:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:455:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:455:BMAX")
  field(DOL2, "QUAD:DIAG0:455:BMAX")
  field(DOL3, "QUAD:DIAG0:455:BMAX")
  field(DOL4, "QUAD:DIAG0:455:BMIN")
  field(DOL5, "QUAD:DIAG0:455:BMIN")
  field(DOL6, "QUAD:DIAG0:455:BMIN")
  field(LNK1, "QUAD:DIAG0:455:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:455:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:455:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:455:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:455:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:455:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:455:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:455:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:455:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:455:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:455:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:455:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:455:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:455:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:455:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:455:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:455:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:455:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:455:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DIAG0:470:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DIAG0:470:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DIAG0:470:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DIAG0:470:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DIAG0:470:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DIAG0:470:EDES.PROC PP")
    field(LNK2, "QUAD:DIAG0:470:EACT.PROC PP")
    field(LNK3, "QUAD:DIAG0:470:EERR.DISA PP")
    field(LNK4, "QUAD:DIAG0:470:ECON.PROC PP")
    field(LNK5, "QUAD:DIAG0:470:BMAGX.PROC PP")
    field(LNK6, "QUAD:DIAG0:470:BMAGY.PROC PP")
    field(LNK7, "QUAD:DIAG0:470:BLEM.PROC PP")
    field(LNK8, "QUAD:DIAG0:470:BMOD.PROC PP")
    field(LNK9, "QUAD:DIAG0:470:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DIAG0:470:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DIAG0:470:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DIAG0:470:BMAX")
  field(DOL2, "QUAD:DIAG0:470:BMAX")
  field(DOL3, "QUAD:DIAG0:470:BMAX")
  field(DOL4, "QUAD:DIAG0:470:BMIN")
  field(DOL5, "QUAD:DIAG0:470:BMIN")
  field(DOL6, "QUAD:DIAG0:470:BMIN")
  field(LNK1, "QUAD:DIAG0:470:BMAGX.HOPR")
  field(LNK2, "QUAD:DIAG0:470:BMAGY.HOPR")
  field(LNK3, "QUAD:DIAG0:470:BLEM.HOPR")
  field(LNK4, "QUAD:DIAG0:470:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DIAG0:470:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DIAG0:470:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:470:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DIAG0:470:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DIAG0:470:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DIAG0:470:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DIAG0:470:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:470:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:470:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:470:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DIAG0:470:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DIAG0:470:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DIAG0:470:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DIAG0:470:EDES NPP MS")
  field(INPB, "QUAD:DIAG0:470:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:178:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:178:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:178:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:178:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:178:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:178:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:178:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:178:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:178:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:178:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:178:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:178:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:178:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:178:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:178:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:178:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:178:BMAX")
  field(DOL2, "XCOR:DIAG0:178:BMAX")
  field(DOL3, "XCOR:DIAG0:178:BMAX")
  field(DOL4, "XCOR:DIAG0:178:BMIN")
  field(DOL5, "XCOR:DIAG0:178:BMIN")
  field(DOL6, "XCOR:DIAG0:178:BMIN")
  field(LNK1, "XCOR:DIAG0:178:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:178:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:178:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:178:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:178:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:178:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:178:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:178:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:178:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:178:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:178:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:178:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:178:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:178:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:178:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:178:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:178:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:178:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:178:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:218:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:218:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:218:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:218:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:218:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:218:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:218:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:218:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:218:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:218:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:218:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:218:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:218:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:218:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:218:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:218:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:218:BMAX")
  field(DOL2, "XCOR:DIAG0:218:BMAX")
  field(DOL3, "XCOR:DIAG0:218:BMAX")
  field(DOL4, "XCOR:DIAG0:218:BMIN")
  field(DOL5, "XCOR:DIAG0:218:BMIN")
  field(DOL6, "XCOR:DIAG0:218:BMIN")
  field(LNK1, "XCOR:DIAG0:218:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:218:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:218:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:218:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:218:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:218:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:218:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:218:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:218:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:218:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:218:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:218:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:218:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:218:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:218:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:218:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:218:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:218:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:218:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:280:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:280:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:280:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:280:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:280:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:280:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:280:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:280:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:280:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:280:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:280:BMAX")
  field(DOL2, "XCOR:DIAG0:280:BMAX")
  field(DOL3, "XCOR:DIAG0:280:BMAX")
  field(DOL4, "XCOR:DIAG0:280:BMIN")
  field(DOL5, "XCOR:DIAG0:280:BMIN")
  field(DOL6, "XCOR:DIAG0:280:BMIN")
  field(LNK1, "XCOR:DIAG0:280:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:280:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:280:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:280:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:280:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:280:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:290:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:290:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:290:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:290:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:290:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:290:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:290:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:290:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:290:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:290:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:290:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:290:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:290:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:290:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:290:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:290:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:290:BMAX")
  field(DOL2, "XCOR:DIAG0:290:BMAX")
  field(DOL3, "XCOR:DIAG0:290:BMAX")
  field(DOL4, "XCOR:DIAG0:290:BMIN")
  field(DOL5, "XCOR:DIAG0:290:BMIN")
  field(DOL6, "XCOR:DIAG0:290:BMIN")
  field(LNK1, "XCOR:DIAG0:290:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:290:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:290:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:290:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:290:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:290:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:290:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:290:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:290:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:290:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:290:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:290:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:290:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:290:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:290:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:290:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:290:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:290:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:290:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:340:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:340:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:340:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:340:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:340:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:340:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:340:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:340:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:340:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:340:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:340:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:340:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:340:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:340:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:340:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:340:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:340:BMAX")
  field(DOL2, "XCOR:DIAG0:340:BMAX")
  field(DOL3, "XCOR:DIAG0:340:BMAX")
  field(DOL4, "XCOR:DIAG0:340:BMIN")
  field(DOL5, "XCOR:DIAG0:340:BMIN")
  field(DOL6, "XCOR:DIAG0:340:BMIN")
  field(LNK1, "XCOR:DIAG0:340:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:340:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:340:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:340:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:340:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:340:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:340:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:340:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:340:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:340:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:340:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:340:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:340:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:340:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:340:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:340:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:340:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:340:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:340:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:380:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:380:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:380:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:380:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:380:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:380:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:380:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:380:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:380:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:380:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:380:BMAX")
  field(DOL2, "XCOR:DIAG0:380:BMAX")
  field(DOL3, "XCOR:DIAG0:380:BMAX")
  field(DOL4, "XCOR:DIAG0:380:BMIN")
  field(DOL5, "XCOR:DIAG0:380:BMIN")
  field(DOL6, "XCOR:DIAG0:380:BMIN")
  field(LNK1, "XCOR:DIAG0:380:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:380:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:380:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:380:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:380:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:380:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DIAG0:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DIAG0:460:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DIAG0:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DIAG0:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DIAG0:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DIAG0:460:EDES.PROC PP")
    field(LNK2, "XCOR:DIAG0:460:EACT.PROC PP")
    field(LNK3, "XCOR:DIAG0:460:EERR.DISA PP")
    field(LNK4, "XCOR:DIAG0:460:ECON.PROC PP")
    field(LNK5, "XCOR:DIAG0:460:BMAGX.PROC PP")
    field(LNK6, "XCOR:DIAG0:460:BMAGY.PROC PP")
    field(LNK7, "XCOR:DIAG0:460:BLEM.PROC PP")
    field(LNK8, "XCOR:DIAG0:460:BMOD.PROC PP")
    field(LNK9, "XCOR:DIAG0:460:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DIAG0:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DIAG0:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DIAG0:460:BMAX")
  field(DOL2, "XCOR:DIAG0:460:BMAX")
  field(DOL3, "XCOR:DIAG0:460:BMAX")
  field(DOL4, "XCOR:DIAG0:460:BMIN")
  field(DOL5, "XCOR:DIAG0:460:BMIN")
  field(DOL6, "XCOR:DIAG0:460:BMIN")
  field(LNK1, "XCOR:DIAG0:460:BMAGX.HOPR")
  field(LNK2, "XCOR:DIAG0:460:BMAGY.HOPR")
  field(LNK3, "XCOR:DIAG0:460:BLEM.HOPR")
  field(LNK4, "XCOR:DIAG0:460:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DIAG0:460:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DIAG0:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DIAG0:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DIAG0:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DIAG0:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DIAG0:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DIAG0:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DIAG0:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DIAG0:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DIAG0:460:EDES NPP MS")
  field(INPB, "XCOR:DIAG0:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:199:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:199:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:199:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:199:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:199:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:199:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:199:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:199:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:199:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:199:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:199:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:199:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:199:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:199:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:199:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:199:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:199:BMAX")
  field(DOL2, "YCOR:DIAG0:199:BMAX")
  field(DOL3, "YCOR:DIAG0:199:BMAX")
  field(DOL4, "YCOR:DIAG0:199:BMIN")
  field(DOL5, "YCOR:DIAG0:199:BMIN")
  field(DOL6, "YCOR:DIAG0:199:BMIN")
  field(LNK1, "YCOR:DIAG0:199:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:199:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:199:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:199:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:199:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:199:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:199:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:199:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:199:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:199:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:199:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:199:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:199:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:199:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:199:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:199:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:199:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:199:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:199:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:247:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:247:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:247:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:247:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:247:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:247:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:247:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:247:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:247:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:247:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:247:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:247:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:247:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:247:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:247:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:247:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:247:BMAX")
  field(DOL2, "YCOR:DIAG0:247:BMAX")
  field(DOL3, "YCOR:DIAG0:247:BMAX")
  field(DOL4, "YCOR:DIAG0:247:BMIN")
  field(DOL5, "YCOR:DIAG0:247:BMIN")
  field(DOL6, "YCOR:DIAG0:247:BMIN")
  field(LNK1, "YCOR:DIAG0:247:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:247:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:247:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:247:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:247:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:247:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:247:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:247:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:247:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:247:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:247:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:247:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:247:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:247:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:247:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:247:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:247:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:247:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:247:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:280:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:280:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:280:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:280:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:280:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:280:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:280:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:280:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:280:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:280:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:280:BMAX")
  field(DOL2, "YCOR:DIAG0:280:BMAX")
  field(DOL3, "YCOR:DIAG0:280:BMAX")
  field(DOL4, "YCOR:DIAG0:280:BMIN")
  field(DOL5, "YCOR:DIAG0:280:BMIN")
  field(DOL6, "YCOR:DIAG0:280:BMIN")
  field(LNK1, "YCOR:DIAG0:280:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:280:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:280:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:280:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:280:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:280:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:290:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:290:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:290:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:290:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:290:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:290:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:290:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:290:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:290:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:290:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:290:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:290:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:290:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:290:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:290:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:290:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:290:BMAX")
  field(DOL2, "YCOR:DIAG0:290:BMAX")
  field(DOL3, "YCOR:DIAG0:290:BMAX")
  field(DOL4, "YCOR:DIAG0:290:BMIN")
  field(DOL5, "YCOR:DIAG0:290:BMIN")
  field(DOL6, "YCOR:DIAG0:290:BMIN")
  field(LNK1, "YCOR:DIAG0:290:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:290:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:290:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:290:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:290:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:290:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:290:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:290:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:290:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:290:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:290:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:290:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:290:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:290:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:290:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:290:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:290:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:290:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:290:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:340:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:340:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:340:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:340:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:340:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:340:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:340:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:340:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:340:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:340:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:340:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:340:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:340:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:340:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:340:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:340:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:340:BMAX")
  field(DOL2, "YCOR:DIAG0:340:BMAX")
  field(DOL3, "YCOR:DIAG0:340:BMAX")
  field(DOL4, "YCOR:DIAG0:340:BMIN")
  field(DOL5, "YCOR:DIAG0:340:BMIN")
  field(DOL6, "YCOR:DIAG0:340:BMIN")
  field(LNK1, "YCOR:DIAG0:340:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:340:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:340:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:340:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:340:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:340:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:340:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:340:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:340:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:340:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:340:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:340:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:340:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:340:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:340:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:340:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:340:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:340:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:340:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:380:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:380:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:380:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:380:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:380:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:380:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:380:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:380:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:380:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:380:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:380:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:380:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:380:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:380:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:380:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:380:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:380:BMAX")
  field(DOL2, "YCOR:DIAG0:380:BMAX")
  field(DOL3, "YCOR:DIAG0:380:BMAX")
  field(DOL4, "YCOR:DIAG0:380:BMIN")
  field(DOL5, "YCOR:DIAG0:380:BMIN")
  field(DOL6, "YCOR:DIAG0:380:BMIN")
  field(LNK1, "YCOR:DIAG0:380:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:380:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:380:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:380:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:380:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:380:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:380:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:380:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:380:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:380:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:380:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:380:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:380:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:380:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:380:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:380:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:380:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:380:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:380:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DIAG0:460:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DIAG0:460:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DIAG0:460:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DIAG0:460:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DIAG0:460:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DIAG0:460:EDES.PROC PP")
    field(LNK2, "YCOR:DIAG0:460:EACT.PROC PP")
    field(LNK3, "YCOR:DIAG0:460:EERR.DISA PP")
    field(LNK4, "YCOR:DIAG0:460:ECON.PROC PP")
    field(LNK5, "YCOR:DIAG0:460:BMAGX.PROC PP")
    field(LNK6, "YCOR:DIAG0:460:BMAGY.PROC PP")
    field(LNK7, "YCOR:DIAG0:460:BLEM.PROC PP")
    field(LNK8, "YCOR:DIAG0:460:BMOD.PROC PP")
    field(LNK9, "YCOR:DIAG0:460:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DIAG0:460:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DIAG0:460:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DIAG0:460:BMAX")
  field(DOL2, "YCOR:DIAG0:460:BMAX")
  field(DOL3, "YCOR:DIAG0:460:BMAX")
  field(DOL4, "YCOR:DIAG0:460:BMIN")
  field(DOL5, "YCOR:DIAG0:460:BMIN")
  field(DOL6, "YCOR:DIAG0:460:BMIN")
  field(LNK1, "YCOR:DIAG0:460:BMAGX.HOPR")
  field(LNK2, "YCOR:DIAG0:460:BMAGY.HOPR")
  field(LNK3, "YCOR:DIAG0:460:BLEM.HOPR")
  field(LNK4, "YCOR:DIAG0:460:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DIAG0:460:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DIAG0:460:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:460:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DIAG0:460:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DIAG0:460:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DIAG0:460:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DIAG0:460:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:460:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:460:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:460:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DIAG0:460:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DIAG0:460:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DIAG0:460:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DIAG0:460:EDES NPP MS")
  field(INPB, "YCOR:DIAG0:460:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L1B:0285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L1B:0285:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L1B:0285:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L1B:0285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L1B:0285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L1B:0285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L1B:0285:EDES.PROC PP")
    field(LNK2, "QUAD:L1B:0285:EACT.PROC PP")
    field(LNK3, "QUAD:L1B:0285:EERR.DISA PP")
    field(LNK4, "QUAD:L1B:0285:ECON.PROC PP")
    field(LNK5, "QUAD:L1B:0285:BMAGX.PROC PP")
    field(LNK6, "QUAD:L1B:0285:BMAGY.PROC PP")
    field(LNK7, "QUAD:L1B:0285:BLEM.PROC PP")
    field(LNK8, "QUAD:L1B:0285:BMOD.PROC PP")
    field(LNK9, "QUAD:L1B:0285:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L1B:0285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L1B:0285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L1B:0285:BMAX")
  field(DOL2, "QUAD:L1B:0285:BMAX")
  field(DOL3, "QUAD:L1B:0285:BMAX")
  field(DOL4, "QUAD:L1B:0285:BMIN")
  field(DOL5, "QUAD:L1B:0285:BMIN")
  field(DOL6, "QUAD:L1B:0285:BMIN")
  field(LNK1, "QUAD:L1B:0285:BMAGX.HOPR")
  field(LNK2, "QUAD:L1B:0285:BMAGY.HOPR")
  field(LNK3, "QUAD:L1B:0285:BLEM.HOPR")
  field(LNK4, "QUAD:L1B:0285:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L1B:0285:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L1B:0285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L1B:0285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L1B:0285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L1B:0285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L1B:0285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L1B:0285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L1B:0285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L1B:0285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L1B:0285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L1B:0285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L1B:0285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L1B:0285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L1B:0285:EDES NPP MS")
  field(INPB, "QUAD:L1B:0285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L1B:0285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L1B:0285:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L1B:0285:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L1B:0285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L1B:0285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L1B:0285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L1B:0285:EDES.PROC PP")
    field(LNK2, "XCOR:L1B:0285:EACT.PROC PP")
    field(LNK3, "XCOR:L1B:0285:EERR.DISA PP")
    field(LNK4, "XCOR:L1B:0285:ECON.PROC PP")
    field(LNK5, "XCOR:L1B:0285:BMAGX.PROC PP")
    field(LNK6, "XCOR:L1B:0285:BMAGY.PROC PP")
    field(LNK7, "XCOR:L1B:0285:BLEM.PROC PP")
    field(LNK8, "XCOR:L1B:0285:BMOD.PROC PP")
    field(LNK9, "XCOR:L1B:0285:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L1B:0285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L1B:0285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L1B:0285:BMAX")
  field(DOL2, "XCOR:L1B:0285:BMAX")
  field(DOL3, "XCOR:L1B:0285:BMAX")
  field(DOL4, "XCOR:L1B:0285:BMIN")
  field(DOL5, "XCOR:L1B:0285:BMIN")
  field(DOL6, "XCOR:L1B:0285:BMIN")
  field(LNK1, "XCOR:L1B:0285:BMAGX.HOPR")
  field(LNK2, "XCOR:L1B:0285:BMAGY.HOPR")
  field(LNK3, "XCOR:L1B:0285:BLEM.HOPR")
  field(LNK4, "XCOR:L1B:0285:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L1B:0285:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L1B:0285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L1B:0285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L1B:0285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L1B:0285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L1B:0285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L1B:0285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L1B:0285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L1B:0285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L1B:0285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L1B:0285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L1B:0285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L1B:0285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L1B:0285:EDES NPP MS")
  field(INPB, "XCOR:L1B:0285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L1B:0285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L1B:0285:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L1B:0285:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L1B:0285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L1B:0285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L1B:0285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L1B:0285:EDES.PROC PP")
    field(LNK2, "YCOR:L1B:0285:EACT.PROC PP")
    field(LNK3, "YCOR:L1B:0285:EERR.DISA PP")
    field(LNK4, "YCOR:L1B:0285:ECON.PROC PP")
    field(LNK5, "YCOR:L1B:0285:BMAGX.PROC PP")
    field(LNK6, "YCOR:L1B:0285:BMAGY.PROC PP")
    field(LNK7, "YCOR:L1B:0285:BLEM.PROC PP")
    field(LNK8, "YCOR:L1B:0285:BMOD.PROC PP")
    field(LNK9, "YCOR:L1B:0285:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L1B:0285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L1B:0285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L1B:0285:BMAX")
  field(DOL2, "YCOR:L1B:0285:BMAX")
  field(DOL3, "YCOR:L1B:0285:BMAX")
  field(DOL4, "YCOR:L1B:0285:BMIN")
  field(DOL5, "YCOR:L1B:0285:BMIN")
  field(DOL6, "YCOR:L1B:0285:BMIN")
  field(LNK1, "YCOR:L1B:0285:BMAGX.HOPR")
  field(LNK2, "YCOR:L1B:0285:BMAGY.HOPR")
  field(LNK3, "YCOR:L1B:0285:BLEM.HOPR")
  field(LNK4, "YCOR:L1B:0285:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L1B:0285:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L1B:0285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L1B:0285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L1B:0285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L1B:0285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L1B:0285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L1B:0285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L1B:0285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L1B:0285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L1B:0285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L1B:0285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L1B:0285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L1B:0285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L1B:0285:EDES NPP MS")
  field(INPB, "YCOR:L1B:0285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L1B:0385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L1B:0385:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L1B:0385:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L1B:0385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L1B:0385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L1B:0385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L1B:0385:EDES.PROC PP")
    field(LNK2, "QUAD:L1B:0385:EACT.PROC PP")
    field(LNK3, "QUAD:L1B:0385:EERR.DISA PP")
    field(LNK4, "QUAD:L1B:0385:ECON.PROC PP")
    field(LNK5, "QUAD:L1B:0385:BMAGX.PROC PP")
    field(LNK6, "QUAD:L1B:0385:BMAGY.PROC PP")
    field(LNK7, "QUAD:L1B:0385:BLEM.PROC PP")
    field(LNK8, "QUAD:L1B:0385:BMOD.PROC PP")
    field(LNK9, "QUAD:L1B:0385:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L1B:0385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L1B:0385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L1B:0385:BMAX")
  field(DOL2, "QUAD:L1B:0385:BMAX")
  field(DOL3, "QUAD:L1B:0385:BMAX")
  field(DOL4, "QUAD:L1B:0385:BMIN")
  field(DOL5, "QUAD:L1B:0385:BMIN")
  field(DOL6, "QUAD:L1B:0385:BMIN")
  field(LNK1, "QUAD:L1B:0385:BMAGX.HOPR")
  field(LNK2, "QUAD:L1B:0385:BMAGY.HOPR")
  field(LNK3, "QUAD:L1B:0385:BLEM.HOPR")
  field(LNK4, "QUAD:L1B:0385:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L1B:0385:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L1B:0385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L1B:0385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L1B:0385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L1B:0385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L1B:0385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L1B:0385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L1B:0385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L1B:0385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L1B:0385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L1B:0385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L1B:0385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L1B:0385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L1B:0385:EDES NPP MS")
  field(INPB, "QUAD:L1B:0385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L1B:0385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L1B:0385:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L1B:0385:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L1B:0385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L1B:0385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L1B:0385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L1B:0385:EDES.PROC PP")
    field(LNK2, "XCOR:L1B:0385:EACT.PROC PP")
    field(LNK3, "XCOR:L1B:0385:EERR.DISA PP")
    field(LNK4, "XCOR:L1B:0385:ECON.PROC PP")
    field(LNK5, "XCOR:L1B:0385:BMAGX.PROC PP")
    field(LNK6, "XCOR:L1B:0385:BMAGY.PROC PP")
    field(LNK7, "XCOR:L1B:0385:BLEM.PROC PP")
    field(LNK8, "XCOR:L1B:0385:BMOD.PROC PP")
    field(LNK9, "XCOR:L1B:0385:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L1B:0385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L1B:0385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L1B:0385:BMAX")
  field(DOL2, "XCOR:L1B:0385:BMAX")
  field(DOL3, "XCOR:L1B:0385:BMAX")
  field(DOL4, "XCOR:L1B:0385:BMIN")
  field(DOL5, "XCOR:L1B:0385:BMIN")
  field(DOL6, "XCOR:L1B:0385:BMIN")
  field(LNK1, "XCOR:L1B:0385:BMAGX.HOPR")
  field(LNK2, "XCOR:L1B:0385:BMAGY.HOPR")
  field(LNK3, "XCOR:L1B:0385:BLEM.HOPR")
  field(LNK4, "XCOR:L1B:0385:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L1B:0385:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L1B:0385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L1B:0385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L1B:0385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L1B:0385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L1B:0385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L1B:0385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L1B:0385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L1B:0385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L1B:0385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L1B:0385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L1B:0385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L1B:0385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L1B:0385:EDES NPP MS")
  field(INPB, "XCOR:L1B:0385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L1B:0385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L1B:0385:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L1B:0385:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L1B:0385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L1B:0385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L1B:0385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L1B:0385:EDES.PROC PP")
    field(LNK2, "YCOR:L1B:0385:EACT.PROC PP")
    field(LNK3, "YCOR:L1B:0385:EERR.DISA PP")
    field(LNK4, "YCOR:L1B:0385:ECON.PROC PP")
    field(LNK5, "YCOR:L1B:0385:BMAGX.PROC PP")
    field(LNK6, "YCOR:L1B:0385:BMAGY.PROC PP")
    field(LNK7, "YCOR:L1B:0385:BLEM.PROC PP")
    field(LNK8, "YCOR:L1B:0385:BMOD.PROC PP")
    field(LNK9, "YCOR:L1B:0385:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L1B:0385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L1B:0385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L1B:0385:BMAX")
  field(DOL2, "YCOR:L1B:0385:BMAX")
  field(DOL3, "YCOR:L1B:0385:BMAX")
  field(DOL4, "YCOR:L1B:0385:BMIN")
  field(DOL5, "YCOR:L1B:0385:BMIN")
  field(DOL6, "YCOR:L1B:0385:BMIN")
  field(LNK1, "YCOR:L1B:0385:BMAGX.HOPR")
  field(LNK2, "YCOR:L1B:0385:BMAGY.HOPR")
  field(LNK3, "YCOR:L1B:0385:BLEM.HOPR")
  field(LNK4, "YCOR:L1B:0385:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L1B:0385:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L1B:0385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L1B:0385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L1B:0385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L1B:0385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L1B:0385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L1B:0385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L1B:0385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L1B:0385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L1B:0385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L1B:0385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L1B:0385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L1B:0385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L1B:0385:EDES NPP MS")
  field(INPB, "YCOR:L1B:0385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC1B:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC1B:400:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC1B:400:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC1B:400:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC1B:400:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC1B:400:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC1B:400:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC1B:400:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC1B:400:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC1B:400:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC1B:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC1B:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC1B:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC1B:400:EDES.PROC PP")
    field(LNK2, "BEND:BC1B:400:EACT.PROC PP")
    field(LNK3, "BEND:BC1B:400:EERR.DISA PP")
    field(LNK4, "BEND:BC1B:400:ECON.PROC PP")
    field(LNK5, "BEND:BC1B:400:BMAGX.PROC PP")
    field(LNK6, "BEND:BC1B:400:BMAGY.PROC PP")
    field(LNK7, "BEND:BC1B:400:BLEM.PROC PP")
    field(LNK8, "BEND:BC1B:400:BMOD.PROC PP")
    field(LNK9, "BEND:BC1B:400:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC1B:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC1B:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC1B:400:BMAX")
  field(DOL2, "BEND:BC1B:400:BMAX")
  field(DOL3, "BEND:BC1B:400:BMAX")
  field(DOL4, "BEND:BC1B:400:BMIN")
  field(DOL5, "BEND:BC1B:400:BMIN")
  field(DOL6, "BEND:BC1B:400:BMIN")
  field(LNK1, "BEND:BC1B:400:BMAGX.HOPR")
  field(LNK2, "BEND:BC1B:400:BMAGY.HOPR")
  field(LNK3, "BEND:BC1B:400:BLEM.HOPR")
  field(LNK4, "BEND:BC1B:400:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC1B:400:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC1B:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC1B:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC1B:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC1B:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:BC1B:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:BC1B:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC1B:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC1B:400:EDES NPP MS")
  field(INPB, "BEND:BC1B:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:BC1B:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:BC1B:200:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:BC1B:200:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:BC1B:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:BC1B:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:BC1B:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:BC1B:200:EDES.PROC PP")
    field(LNK2, "BTRM:BC1B:200:EACT.PROC PP")
    field(LNK3, "BTRM:BC1B:200:EERR.DISA PP")
    field(LNK4, "BTRM:BC1B:200:ECON.PROC PP")
    field(LNK5, "BTRM:BC1B:200:BMAGX.PROC PP")
    field(LNK6, "BTRM:BC1B:200:BMAGY.PROC PP")
    field(LNK7, "BTRM:BC1B:200:BLEM.PROC PP")
    field(LNK8, "BTRM:BC1B:200:BMOD.PROC PP")
    field(LNK9, "BTRM:BC1B:200:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:BC1B:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:BC1B:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:BC1B:200:BMAX")
  field(DOL2, "BTRM:BC1B:200:BMAX")
  field(DOL3, "BTRM:BC1B:200:BMAX")
  field(DOL4, "BTRM:BC1B:200:BMIN")
  field(DOL5, "BTRM:BC1B:200:BMIN")
  field(DOL6, "BTRM:BC1B:200:BMIN")
  field(LNK1, "BTRM:BC1B:200:BMAGX.HOPR")
  field(LNK2, "BTRM:BC1B:200:BMAGY.HOPR")
  field(LNK3, "BTRM:BC1B:200:BLEM.HOPR")
  field(LNK4, "BTRM:BC1B:200:BMAGX.LOPR PP")
  field(LNK5, "BTRM:BC1B:200:BMAGY.LOPR PP")
  field(LNK6, "BTRM:BC1B:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:BC1B:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:BC1B:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:BC1B:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:BC1B:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:BC1B:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC1B:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC1B:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:BC1B:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:BC1B:200:EDES NPP MS")
  field(INPB, "BTRM:BC1B:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:BC1B:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:BC1B:600:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:BC1B:600:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:BC1B:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:BC1B:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:BC1B:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:BC1B:600:EDES.PROC PP")
    field(LNK2, "BTRM:BC1B:600:EACT.PROC PP")
    field(LNK3, "BTRM:BC1B:600:EERR.DISA PP")
    field(LNK4, "BTRM:BC1B:600:ECON.PROC PP")
    field(LNK5, "BTRM:BC1B:600:BMAGX.PROC PP")
    field(LNK6, "BTRM:BC1B:600:BMAGY.PROC PP")
    field(LNK7, "BTRM:BC1B:600:BLEM.PROC PP")
    field(LNK8, "BTRM:BC1B:600:BMOD.PROC PP")
    field(LNK9, "BTRM:BC1B:600:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:BC1B:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:BC1B:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:BC1B:600:BMAX")
  field(DOL2, "BTRM:BC1B:600:BMAX")
  field(DOL3, "BTRM:BC1B:600:BMAX")
  field(DOL4, "BTRM:BC1B:600:BMIN")
  field(DOL5, "BTRM:BC1B:600:BMIN")
  field(DOL6, "BTRM:BC1B:600:BMIN")
  field(LNK1, "BTRM:BC1B:600:BMAGX.HOPR")
  field(LNK2, "BTRM:BC1B:600:BMAGY.HOPR")
  field(LNK3, "BTRM:BC1B:600:BLEM.HOPR")
  field(LNK4, "BTRM:BC1B:600:BMAGX.LOPR PP")
  field(LNK5, "BTRM:BC1B:600:BMAGY.LOPR PP")
  field(LNK6, "BTRM:BC1B:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:BC1B:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:BC1B:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:BC1B:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:BC1B:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:BC1B:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC1B:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC1B:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:BC1B:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:BC1B:600:EDES NPP MS")
  field(INPB, "BTRM:BC1B:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:BC1B:800:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:BC1B:800:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:BC1B:800:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:BC1B:800:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:BC1B:800:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:BC1B:800:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:BC1B:800:EDES.PROC PP")
    field(LNK2, "BTRM:BC1B:800:EACT.PROC PP")
    field(LNK3, "BTRM:BC1B:800:EERR.DISA PP")
    field(LNK4, "BTRM:BC1B:800:ECON.PROC PP")
    field(LNK5, "BTRM:BC1B:800:BMAGX.PROC PP")
    field(LNK6, "BTRM:BC1B:800:BMAGY.PROC PP")
    field(LNK7, "BTRM:BC1B:800:BLEM.PROC PP")
    field(LNK8, "BTRM:BC1B:800:BMOD.PROC PP")
    field(LNK9, "BTRM:BC1B:800:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:BC1B:800:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:BC1B:800:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:BC1B:800:BMAX")
  field(DOL2, "BTRM:BC1B:800:BMAX")
  field(DOL3, "BTRM:BC1B:800:BMAX")
  field(DOL4, "BTRM:BC1B:800:BMIN")
  field(DOL5, "BTRM:BC1B:800:BMIN")
  field(DOL6, "BTRM:BC1B:800:BMIN")
  field(LNK1, "BTRM:BC1B:800:BMAGX.HOPR")
  field(LNK2, "BTRM:BC1B:800:BMAGY.HOPR")
  field(LNK3, "BTRM:BC1B:800:BLEM.HOPR")
  field(LNK4, "BTRM:BC1B:800:BMAGX.LOPR PP")
  field(LNK5, "BTRM:BC1B:800:BMAGY.LOPR PP")
  field(LNK6, "BTRM:BC1B:800:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:BC1B:800:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:BC1B:800:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:BC1B:800:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:BC1B:800:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:BC1B:800:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:800:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:800:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC1B:800:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC1B:800:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC1B:800:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:BC1B:800:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:BC1B:800:EDES NPP MS")
  field(INPB, "BTRM:BC1B:800:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BC1B:125:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BC1B:125:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BC1B:125:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BC1B:125:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BC1B:125:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BC1B:125:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BC1B:125:EDES.PROC PP")
    field(LNK2, "QUAD:BC1B:125:EACT.PROC PP")
    field(LNK3, "QUAD:BC1B:125:EERR.DISA PP")
    field(LNK4, "QUAD:BC1B:125:ECON.PROC PP")
    field(LNK5, "QUAD:BC1B:125:BMAGX.PROC PP")
    field(LNK6, "QUAD:BC1B:125:BMAGY.PROC PP")
    field(LNK7, "QUAD:BC1B:125:BLEM.PROC PP")
    field(LNK8, "QUAD:BC1B:125:BMOD.PROC PP")
    field(LNK9, "QUAD:BC1B:125:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BC1B:125:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BC1B:125:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BC1B:125:BMAX")
  field(DOL2, "QUAD:BC1B:125:BMAX")
  field(DOL3, "QUAD:BC1B:125:BMAX")
  field(DOL4, "QUAD:BC1B:125:BMIN")
  field(DOL5, "QUAD:BC1B:125:BMIN")
  field(DOL6, "QUAD:BC1B:125:BMIN")
  field(LNK1, "QUAD:BC1B:125:BMAGX.HOPR")
  field(LNK2, "QUAD:BC1B:125:BMAGY.HOPR")
  field(LNK3, "QUAD:BC1B:125:BLEM.HOPR")
  field(LNK4, "QUAD:BC1B:125:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BC1B:125:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BC1B:125:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BC1B:125:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BC1B:125:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BC1B:125:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BC1B:125:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BC1B:125:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:125:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:125:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC1B:125:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:125:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC1B:125:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BC1B:125:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BC1B:125:EDES NPP MS")
  field(INPB, "QUAD:BC1B:125:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BC1B:250:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BC1B:250:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BC1B:250:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BC1B:250:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BC1B:250:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BC1B:250:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BC1B:250:EDES.PROC PP")
    field(LNK2, "QUAD:BC1B:250:EACT.PROC PP")
    field(LNK3, "QUAD:BC1B:250:EERR.DISA PP")
    field(LNK4, "QUAD:BC1B:250:ECON.PROC PP")
    field(LNK5, "QUAD:BC1B:250:BMAGX.PROC PP")
    field(LNK6, "QUAD:BC1B:250:BMAGY.PROC PP")
    field(LNK7, "QUAD:BC1B:250:BLEM.PROC PP")
    field(LNK8, "QUAD:BC1B:250:BMOD.PROC PP")
    field(LNK9, "QUAD:BC1B:250:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BC1B:250:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BC1B:250:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BC1B:250:BMAX")
  field(DOL2, "QUAD:BC1B:250:BMAX")
  field(DOL3, "QUAD:BC1B:250:BMAX")
  field(DOL4, "QUAD:BC1B:250:BMIN")
  field(DOL5, "QUAD:BC1B:250:BMIN")
  field(DOL6, "QUAD:BC1B:250:BMIN")
  field(LNK1, "QUAD:BC1B:250:BMAGX.HOPR")
  field(LNK2, "QUAD:BC1B:250:BMAGY.HOPR")
  field(LNK3, "QUAD:BC1B:250:BLEM.HOPR")
  field(LNK4, "QUAD:BC1B:250:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BC1B:250:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BC1B:250:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BC1B:250:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BC1B:250:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BC1B:250:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BC1B:250:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BC1B:250:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:250:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:250:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC1B:250:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:250:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC1B:250:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BC1B:250:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BC1B:250:EDES NPP MS")
  field(INPB, "QUAD:BC1B:250:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BC1B:750:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BC1B:750:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BC1B:750:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BC1B:750:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BC1B:750:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BC1B:750:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BC1B:750:EDES.PROC PP")
    field(LNK2, "QUAD:BC1B:750:EACT.PROC PP")
    field(LNK3, "QUAD:BC1B:750:EERR.DISA PP")
    field(LNK4, "QUAD:BC1B:750:ECON.PROC PP")
    field(LNK5, "QUAD:BC1B:750:BMAGX.PROC PP")
    field(LNK6, "QUAD:BC1B:750:BMAGY.PROC PP")
    field(LNK7, "QUAD:BC1B:750:BLEM.PROC PP")
    field(LNK8, "QUAD:BC1B:750:BMOD.PROC PP")
    field(LNK9, "QUAD:BC1B:750:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BC1B:750:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BC1B:750:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BC1B:750:BMAX")
  field(DOL2, "QUAD:BC1B:750:BMAX")
  field(DOL3, "QUAD:BC1B:750:BMAX")
  field(DOL4, "QUAD:BC1B:750:BMIN")
  field(DOL5, "QUAD:BC1B:750:BMIN")
  field(DOL6, "QUAD:BC1B:750:BMIN")
  field(LNK1, "QUAD:BC1B:750:BMAGX.HOPR")
  field(LNK2, "QUAD:BC1B:750:BMAGY.HOPR")
  field(LNK3, "QUAD:BC1B:750:BLEM.HOPR")
  field(LNK4, "QUAD:BC1B:750:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BC1B:750:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BC1B:750:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BC1B:750:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BC1B:750:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BC1B:750:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BC1B:750:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BC1B:750:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:750:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:750:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC1B:750:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC1B:750:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC1B:750:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BC1B:750:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BC1B:750:EDES NPP MS")
  field(INPB, "QUAD:BC1B:750:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BC1B:100:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BC1B:100:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BC1B:100:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BC1B:100:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BC1B:100:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BC1B:100:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BC1B:100:EDES.PROC PP")
    field(LNK2, "XCOR:BC1B:100:EACT.PROC PP")
    field(LNK3, "XCOR:BC1B:100:EERR.DISA PP")
    field(LNK4, "XCOR:BC1B:100:ECON.PROC PP")
    field(LNK5, "XCOR:BC1B:100:BMAGX.PROC PP")
    field(LNK6, "XCOR:BC1B:100:BMAGY.PROC PP")
    field(LNK7, "XCOR:BC1B:100:BLEM.PROC PP")
    field(LNK8, "XCOR:BC1B:100:BMOD.PROC PP")
    field(LNK9, "XCOR:BC1B:100:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BC1B:100:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BC1B:100:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BC1B:100:BMAX")
  field(DOL2, "XCOR:BC1B:100:BMAX")
  field(DOL3, "XCOR:BC1B:100:BMAX")
  field(DOL4, "XCOR:BC1B:100:BMIN")
  field(DOL5, "XCOR:BC1B:100:BMIN")
  field(DOL6, "XCOR:BC1B:100:BMIN")
  field(LNK1, "XCOR:BC1B:100:BMAGX.HOPR")
  field(LNK2, "XCOR:BC1B:100:BMAGY.HOPR")
  field(LNK3, "XCOR:BC1B:100:BLEM.HOPR")
  field(LNK4, "XCOR:BC1B:100:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BC1B:100:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BC1B:100:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BC1B:100:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BC1B:100:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BC1B:100:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BC1B:100:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BC1B:100:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC1B:100:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC1B:100:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BC1B:100:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC1B:100:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BC1B:100:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BC1B:100:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BC1B:100:EDES NPP MS")
  field(INPB, "XCOR:BC1B:100:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BC1B:722:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BC1B:722:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BC1B:722:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BC1B:722:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BC1B:722:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BC1B:722:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BC1B:722:EDES.PROC PP")
    field(LNK2, "XCOR:BC1B:722:EACT.PROC PP")
    field(LNK3, "XCOR:BC1B:722:EERR.DISA PP")
    field(LNK4, "XCOR:BC1B:722:ECON.PROC PP")
    field(LNK5, "XCOR:BC1B:722:BMAGX.PROC PP")
    field(LNK6, "XCOR:BC1B:722:BMAGY.PROC PP")
    field(LNK7, "XCOR:BC1B:722:BLEM.PROC PP")
    field(LNK8, "XCOR:BC1B:722:BMOD.PROC PP")
    field(LNK9, "XCOR:BC1B:722:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BC1B:722:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BC1B:722:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BC1B:722:BMAX")
  field(DOL2, "XCOR:BC1B:722:BMAX")
  field(DOL3, "XCOR:BC1B:722:BMAX")
  field(DOL4, "XCOR:BC1B:722:BMIN")
  field(DOL5, "XCOR:BC1B:722:BMIN")
  field(DOL6, "XCOR:BC1B:722:BMIN")
  field(LNK1, "XCOR:BC1B:722:BMAGX.HOPR")
  field(LNK2, "XCOR:BC1B:722:BMAGY.HOPR")
  field(LNK3, "XCOR:BC1B:722:BLEM.HOPR")
  field(LNK4, "XCOR:BC1B:722:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BC1B:722:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BC1B:722:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BC1B:722:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BC1B:722:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BC1B:722:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BC1B:722:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BC1B:722:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC1B:722:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC1B:722:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BC1B:722:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC1B:722:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BC1B:722:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BC1B:722:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BC1B:722:EDES NPP MS")
  field(INPB, "XCOR:BC1B:722:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BC1B:100:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BC1B:100:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BC1B:100:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BC1B:100:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BC1B:100:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BC1B:100:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BC1B:100:EDES.PROC PP")
    field(LNK2, "YCOR:BC1B:100:EACT.PROC PP")
    field(LNK3, "YCOR:BC1B:100:EERR.DISA PP")
    field(LNK4, "YCOR:BC1B:100:ECON.PROC PP")
    field(LNK5, "YCOR:BC1B:100:BMAGX.PROC PP")
    field(LNK6, "YCOR:BC1B:100:BMAGY.PROC PP")
    field(LNK7, "YCOR:BC1B:100:BLEM.PROC PP")
    field(LNK8, "YCOR:BC1B:100:BMOD.PROC PP")
    field(LNK9, "YCOR:BC1B:100:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BC1B:100:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BC1B:100:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BC1B:100:BMAX")
  field(DOL2, "YCOR:BC1B:100:BMAX")
  field(DOL3, "YCOR:BC1B:100:BMAX")
  field(DOL4, "YCOR:BC1B:100:BMIN")
  field(DOL5, "YCOR:BC1B:100:BMIN")
  field(DOL6, "YCOR:BC1B:100:BMIN")
  field(LNK1, "YCOR:BC1B:100:BMAGX.HOPR")
  field(LNK2, "YCOR:BC1B:100:BMAGY.HOPR")
  field(LNK3, "YCOR:BC1B:100:BLEM.HOPR")
  field(LNK4, "YCOR:BC1B:100:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BC1B:100:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BC1B:100:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BC1B:100:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BC1B:100:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BC1B:100:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BC1B:100:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BC1B:100:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC1B:100:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC1B:100:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BC1B:100:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC1B:100:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BC1B:100:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BC1B:100:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BC1B:100:EDES NPP MS")
  field(INPB, "YCOR:BC1B:100:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BC1B:277:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BC1B:277:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BC1B:277:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BC1B:277:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BC1B:277:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BC1B:277:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BC1B:277:EDES.PROC PP")
    field(LNK2, "YCOR:BC1B:277:EACT.PROC PP")
    field(LNK3, "YCOR:BC1B:277:EERR.DISA PP")
    field(LNK4, "YCOR:BC1B:277:ECON.PROC PP")
    field(LNK5, "YCOR:BC1B:277:BMAGX.PROC PP")
    field(LNK6, "YCOR:BC1B:277:BMAGY.PROC PP")
    field(LNK7, "YCOR:BC1B:277:BLEM.PROC PP")
    field(LNK8, "YCOR:BC1B:277:BMOD.PROC PP")
    field(LNK9, "YCOR:BC1B:277:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BC1B:277:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BC1B:277:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BC1B:277:BMAX")
  field(DOL2, "YCOR:BC1B:277:BMAX")
  field(DOL3, "YCOR:BC1B:277:BMAX")
  field(DOL4, "YCOR:BC1B:277:BMIN")
  field(DOL5, "YCOR:BC1B:277:BMIN")
  field(DOL6, "YCOR:BC1B:277:BMIN")
  field(LNK1, "YCOR:BC1B:277:BMAGX.HOPR")
  field(LNK2, "YCOR:BC1B:277:BMAGY.HOPR")
  field(LNK3, "YCOR:BC1B:277:BLEM.HOPR")
  field(LNK4, "YCOR:BC1B:277:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BC1B:277:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BC1B:277:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BC1B:277:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BC1B:277:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BC1B:277:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BC1B:277:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BC1B:277:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC1B:277:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC1B:277:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BC1B:277:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC1B:277:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BC1B:277:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BC1B:277:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BC1B:277:EDES NPP MS")
  field(INPB, "YCOR:BC1B:277:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:120:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:120:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:120:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:120:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:120:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:120:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:120:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:120:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:120:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:120:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:120:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:120:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:120:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:120:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:120:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:120:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:120:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:120:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:120:BMAX")
  field(DOL2, "QUAD:COL1:120:BMAX")
  field(DOL3, "QUAD:COL1:120:BMAX")
  field(DOL4, "QUAD:COL1:120:BMIN")
  field(DOL5, "QUAD:COL1:120:BMIN")
  field(DOL6, "QUAD:COL1:120:BMIN")
  field(LNK1, "QUAD:COL1:120:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:120:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:120:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:120:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:120:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:120:EDES NPP MS")
  field(INPB, "QUAD:COL1:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:260:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:260:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:260:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:260:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:260:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:260:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:260:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:260:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:260:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:260:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:260:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:260:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:260:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:260:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:260:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:260:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:260:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:260:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:260:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:260:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:260:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:260:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:260:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:260:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:260:BMAX")
  field(DOL2, "QUAD:COL1:260:BMAX")
  field(DOL3, "QUAD:COL1:260:BMAX")
  field(DOL4, "QUAD:COL1:260:BMIN")
  field(DOL5, "QUAD:COL1:260:BMIN")
  field(DOL6, "QUAD:COL1:260:BMIN")
  field(LNK1, "QUAD:COL1:260:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:260:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:260:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:260:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:260:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:260:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:260:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:260:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:260:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:260:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:260:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:260:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:260:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:260:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:260:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:260:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:260:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:260:EDES NPP MS")
  field(INPB, "QUAD:COL1:260:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:280:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:280:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:280:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:280:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:280:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:280:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:280:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:280:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:280:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:280:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:280:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:280:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:280:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:280:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:280:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:280:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:280:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:280:BMAX")
  field(DOL2, "QUAD:COL1:280:BMAX")
  field(DOL3, "QUAD:COL1:280:BMAX")
  field(DOL4, "QUAD:COL1:280:BMIN")
  field(DOL5, "QUAD:COL1:280:BMIN")
  field(DOL6, "QUAD:COL1:280:BMIN")
  field(LNK1, "QUAD:COL1:280:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:280:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:280:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:280:EDES NPP MS")
  field(INPB, "QUAD:COL1:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:320:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:320:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:320:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:320:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:320:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:320:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:320:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:320:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:320:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:320:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:320:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:320:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:320:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:320:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:320:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:320:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:320:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:320:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:320:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:320:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:320:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:320:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:320:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:320:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:320:BMAX")
  field(DOL2, "QUAD:COL1:320:BMAX")
  field(DOL3, "QUAD:COL1:320:BMAX")
  field(DOL4, "QUAD:COL1:320:BMIN")
  field(DOL5, "QUAD:COL1:320:BMIN")
  field(DOL6, "QUAD:COL1:320:BMIN")
  field(LNK1, "QUAD:COL1:320:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:320:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:320:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:320:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:320:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:320:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:320:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:320:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:320:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:320:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:320:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:320:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:320:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:320:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:320:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:320:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:320:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:320:EDES NPP MS")
  field(INPB, "QUAD:COL1:320:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:400:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:400:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:400:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:400:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:400:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:400:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:400:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:400:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:400:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:400:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:400:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:400:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:400:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:400:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:400:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:400:BMAX")
  field(DOL2, "QUAD:COL1:400:BMAX")
  field(DOL3, "QUAD:COL1:400:BMAX")
  field(DOL4, "QUAD:COL1:400:BMIN")
  field(DOL5, "QUAD:COL1:400:BMIN")
  field(DOL6, "QUAD:COL1:400:BMIN")
  field(LNK1, "QUAD:COL1:400:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:400:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:400:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:400:EDES NPP MS")
  field(INPB, "QUAD:COL1:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:480:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:480:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:480:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:480:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:480:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:480:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:480:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:480:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:480:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:480:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:480:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:480:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:480:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:480:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:480:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:480:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:480:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:480:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:480:BMAX")
  field(DOL2, "QUAD:COL1:480:BMAX")
  field(DOL3, "QUAD:COL1:480:BMAX")
  field(DOL4, "QUAD:COL1:480:BMIN")
  field(DOL5, "QUAD:COL1:480:BMIN")
  field(DOL6, "QUAD:COL1:480:BMIN")
  field(LNK1, "QUAD:COL1:480:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:480:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:480:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:480:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:480:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:480:EDES NPP MS")
  field(INPB, "QUAD:COL1:480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:560:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:560:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:560:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:560:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:560:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:560:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:560:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:560:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:560:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:560:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:560:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:560:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:560:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:560:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:560:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:560:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:560:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:560:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:560:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:560:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:560:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:560:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:560:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:560:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:560:BMAX")
  field(DOL2, "QUAD:COL1:560:BMAX")
  field(DOL3, "QUAD:COL1:560:BMAX")
  field(DOL4, "QUAD:COL1:560:BMIN")
  field(DOL5, "QUAD:COL1:560:BMIN")
  field(DOL6, "QUAD:COL1:560:BMIN")
  field(LNK1, "QUAD:COL1:560:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:560:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:560:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:560:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:560:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:560:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:560:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:560:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:560:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:560:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:560:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:560:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:560:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:560:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:560:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:560:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:560:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:560:EDES NPP MS")
  field(INPB, "QUAD:COL1:560:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:640:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:640:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:640:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:640:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:640:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:640:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:640:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:640:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:640:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:640:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:640:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:640:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:640:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:640:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:640:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:640:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:640:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:640:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:640:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:640:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:640:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:640:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:640:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:640:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:640:BMAX")
  field(DOL2, "QUAD:COL1:640:BMAX")
  field(DOL3, "QUAD:COL1:640:BMAX")
  field(DOL4, "QUAD:COL1:640:BMIN")
  field(DOL5, "QUAD:COL1:640:BMIN")
  field(DOL6, "QUAD:COL1:640:BMIN")
  field(LNK1, "QUAD:COL1:640:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:640:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:640:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:640:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:640:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:640:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:640:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:640:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:640:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:640:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:640:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:640:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:640:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:640:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:640:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:640:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:640:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:640:EDES NPP MS")
  field(INPB, "QUAD:COL1:640:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:720:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:720:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:720:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:720:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:720:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:720:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:720:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:720:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:720:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:720:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:720:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:720:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:720:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:720:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:720:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:720:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:720:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:720:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:720:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:720:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:720:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:720:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:720:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:720:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:720:BMAX")
  field(DOL2, "QUAD:COL1:720:BMAX")
  field(DOL3, "QUAD:COL1:720:BMAX")
  field(DOL4, "QUAD:COL1:720:BMIN")
  field(DOL5, "QUAD:COL1:720:BMIN")
  field(DOL6, "QUAD:COL1:720:BMIN")
  field(LNK1, "QUAD:COL1:720:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:720:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:720:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:720:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:720:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:720:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:720:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:720:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:720:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:720:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:720:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:720:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:720:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:720:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:720:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:720:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:720:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:720:EDES NPP MS")
  field(INPB, "QUAD:COL1:720:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:800:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:800:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:800:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:800:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:800:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:800:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:800:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:800:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:800:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:800:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:800:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:800:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:800:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:800:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:800:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:800:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:800:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:800:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:800:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:800:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:800:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:800:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:800:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:800:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:800:BMAX")
  field(DOL2, "QUAD:COL1:800:BMAX")
  field(DOL3, "QUAD:COL1:800:BMAX")
  field(DOL4, "QUAD:COL1:800:BMIN")
  field(DOL5, "QUAD:COL1:800:BMIN")
  field(DOL6, "QUAD:COL1:800:BMIN")
  field(LNK1, "QUAD:COL1:800:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:800:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:800:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:800:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:800:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:800:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:800:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:800:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:800:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:800:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:800:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:800:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:800:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:800:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:800:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:800:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:800:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:800:EDES NPP MS")
  field(INPB, "QUAD:COL1:800:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:880:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:880:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:880:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:880:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:880:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:880:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:880:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:880:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:880:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:880:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:880:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:880:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:880:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:880:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:880:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:880:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:880:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:880:BMAX")
  field(DOL2, "QUAD:COL1:880:BMAX")
  field(DOL3, "QUAD:COL1:880:BMAX")
  field(DOL4, "QUAD:COL1:880:BMIN")
  field(DOL5, "QUAD:COL1:880:BMIN")
  field(DOL6, "QUAD:COL1:880:BMIN")
  field(LNK1, "QUAD:COL1:880:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:880:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:880:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:880:EDES NPP MS")
  field(INPB, "QUAD:COL1:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:COL1:960:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:COL1:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:COL1:1:CTRL.RVAL")
  field(LNK1, "QUAD:COL1:960:FUNC CA PP")
  field(DOL2, "MGNT:COL1:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:COL1:960:FUNC CA PP")
  field(DOL3, "MGNT:COL1:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:COL1:960:FUNC CA PP")
  field(DOL4, "MGNT:COL1:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:COL1:960:FUNC CA PP")
  field(DOL5, "MGNT:COL1:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:COL1:960:FUNC CA PP")
  field(DOL6, "MGNT:COL1:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:COL1:960:FUNC CA PP")
  field(DOL7, "MGNT:COL1:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:COL1:960:FUNC CA PP")
  field(DOL8, "MGNT:COL1:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:COL1:960:FUNC CA PP")
  field(DOL9, "MGNT:COL1:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:COL1:960:FUNC CA PP")
  field(DOLA, "MGNT:COL1:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:COL1:960:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:COL1:960:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:COL1:960:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:COL1:960:EDES.PROC PP")
    field(LNK2, "QUAD:COL1:960:EACT.PROC PP")
    field(LNK3, "QUAD:COL1:960:EERR.DISA PP")
    field(LNK4, "QUAD:COL1:960:ECON.PROC PP")
    field(LNK5, "QUAD:COL1:960:BMAGX.PROC PP")
    field(LNK6, "QUAD:COL1:960:BMAGY.PROC PP")
    field(LNK7, "QUAD:COL1:960:BLEM.PROC PP")
    field(LNK8, "QUAD:COL1:960:BMOD.PROC PP")
    field(LNK9, "QUAD:COL1:960:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:COL1:960:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:COL1:960:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:COL1:960:BMAX")
  field(DOL2, "QUAD:COL1:960:BMAX")
  field(DOL3, "QUAD:COL1:960:BMAX")
  field(DOL4, "QUAD:COL1:960:BMIN")
  field(DOL5, "QUAD:COL1:960:BMIN")
  field(DOL6, "QUAD:COL1:960:BMIN")
  field(LNK1, "QUAD:COL1:960:BMAGX.HOPR")
  field(LNK2, "QUAD:COL1:960:BMAGY.HOPR")
  field(LNK3, "QUAD:COL1:960:BLEM.HOPR")
  field(LNK4, "QUAD:COL1:960:BMAGX.LOPR PP")
  field(LNK5, "QUAD:COL1:960:BMAGY.LOPR PP")
  field(LNK6, "QUAD:COL1:960:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:960:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:COL1:960:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:COL1:960:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:COL1:960:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:COL1:960:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:960:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:960:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:960:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:COL1:960:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:COL1:960:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:COL1:960:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:COL1:960:EDES NPP MS")
  field(INPB, "QUAD:COL1:960:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL1:128:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL1:128:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL1:128:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL1:128:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL1:128:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL1:128:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL1:128:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL1:128:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL1:128:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL1:128:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL1:128:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL1:128:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL1:128:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL1:128:EDES.PROC PP")
    field(LNK2, "XCOR:COL1:128:EACT.PROC PP")
    field(LNK3, "XCOR:COL1:128:EERR.DISA PP")
    field(LNK4, "XCOR:COL1:128:ECON.PROC PP")
    field(LNK5, "XCOR:COL1:128:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL1:128:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL1:128:BLEM.PROC PP")
    field(LNK8, "XCOR:COL1:128:BMOD.PROC PP")
    field(LNK9, "XCOR:COL1:128:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL1:128:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL1:128:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL1:128:BMAX")
  field(DOL2, "XCOR:COL1:128:BMAX")
  field(DOL3, "XCOR:COL1:128:BMAX")
  field(DOL4, "XCOR:COL1:128:BMIN")
  field(DOL5, "XCOR:COL1:128:BMIN")
  field(DOL6, "XCOR:COL1:128:BMIN")
  field(LNK1, "XCOR:COL1:128:BMAGX.HOPR")
  field(LNK2, "XCOR:COL1:128:BMAGY.HOPR")
  field(LNK3, "XCOR:COL1:128:BLEM.HOPR")
  field(LNK4, "XCOR:COL1:128:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL1:128:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL1:128:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:128:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:128:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL1:128:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL1:128:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL1:128:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:128:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:128:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:128:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:128:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:128:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL1:128:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL1:128:EDES NPP MS")
  field(INPB, "XCOR:COL1:128:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL1:328:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL1:328:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL1:328:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL1:328:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL1:328:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL1:328:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL1:328:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL1:328:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL1:328:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL1:328:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL1:328:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL1:328:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL1:328:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL1:328:EDES.PROC PP")
    field(LNK2, "XCOR:COL1:328:EACT.PROC PP")
    field(LNK3, "XCOR:COL1:328:EERR.DISA PP")
    field(LNK4, "XCOR:COL1:328:ECON.PROC PP")
    field(LNK5, "XCOR:COL1:328:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL1:328:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL1:328:BLEM.PROC PP")
    field(LNK8, "XCOR:COL1:328:BMOD.PROC PP")
    field(LNK9, "XCOR:COL1:328:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL1:328:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL1:328:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL1:328:BMAX")
  field(DOL2, "XCOR:COL1:328:BMAX")
  field(DOL3, "XCOR:COL1:328:BMAX")
  field(DOL4, "XCOR:COL1:328:BMIN")
  field(DOL5, "XCOR:COL1:328:BMIN")
  field(DOL6, "XCOR:COL1:328:BMIN")
  field(LNK1, "XCOR:COL1:328:BMAGX.HOPR")
  field(LNK2, "XCOR:COL1:328:BMAGY.HOPR")
  field(LNK3, "XCOR:COL1:328:BLEM.HOPR")
  field(LNK4, "XCOR:COL1:328:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL1:328:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL1:328:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:328:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:328:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL1:328:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL1:328:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL1:328:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:328:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:328:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:328:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:328:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:328:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL1:328:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL1:328:EDES NPP MS")
  field(INPB, "XCOR:COL1:328:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL1:488:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL1:488:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL1:488:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL1:488:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL1:488:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL1:488:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL1:488:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL1:488:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL1:488:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL1:488:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL1:488:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL1:488:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL1:488:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL1:488:EDES.PROC PP")
    field(LNK2, "XCOR:COL1:488:EACT.PROC PP")
    field(LNK3, "XCOR:COL1:488:EERR.DISA PP")
    field(LNK4, "XCOR:COL1:488:ECON.PROC PP")
    field(LNK5, "XCOR:COL1:488:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL1:488:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL1:488:BLEM.PROC PP")
    field(LNK8, "XCOR:COL1:488:BMOD.PROC PP")
    field(LNK9, "XCOR:COL1:488:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL1:488:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL1:488:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL1:488:BMAX")
  field(DOL2, "XCOR:COL1:488:BMAX")
  field(DOL3, "XCOR:COL1:488:BMAX")
  field(DOL4, "XCOR:COL1:488:BMIN")
  field(DOL5, "XCOR:COL1:488:BMIN")
  field(DOL6, "XCOR:COL1:488:BMIN")
  field(LNK1, "XCOR:COL1:488:BMAGX.HOPR")
  field(LNK2, "XCOR:COL1:488:BMAGY.HOPR")
  field(LNK3, "XCOR:COL1:488:BLEM.HOPR")
  field(LNK4, "XCOR:COL1:488:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL1:488:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL1:488:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:488:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:488:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL1:488:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL1:488:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL1:488:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:488:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:488:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:488:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:488:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:488:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL1:488:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL1:488:EDES NPP MS")
  field(INPB, "XCOR:COL1:488:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL1:648:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL1:648:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL1:648:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL1:648:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL1:648:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL1:648:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL1:648:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL1:648:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL1:648:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL1:648:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL1:648:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL1:648:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL1:648:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL1:648:EDES.PROC PP")
    field(LNK2, "XCOR:COL1:648:EACT.PROC PP")
    field(LNK3, "XCOR:COL1:648:EERR.DISA PP")
    field(LNK4, "XCOR:COL1:648:ECON.PROC PP")
    field(LNK5, "XCOR:COL1:648:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL1:648:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL1:648:BLEM.PROC PP")
    field(LNK8, "XCOR:COL1:648:BMOD.PROC PP")
    field(LNK9, "XCOR:COL1:648:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL1:648:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL1:648:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL1:648:BMAX")
  field(DOL2, "XCOR:COL1:648:BMAX")
  field(DOL3, "XCOR:COL1:648:BMAX")
  field(DOL4, "XCOR:COL1:648:BMIN")
  field(DOL5, "XCOR:COL1:648:BMIN")
  field(DOL6, "XCOR:COL1:648:BMIN")
  field(LNK1, "XCOR:COL1:648:BMAGX.HOPR")
  field(LNK2, "XCOR:COL1:648:BMAGY.HOPR")
  field(LNK3, "XCOR:COL1:648:BLEM.HOPR")
  field(LNK4, "XCOR:COL1:648:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL1:648:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL1:648:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:648:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:648:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL1:648:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL1:648:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL1:648:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:648:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:648:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:648:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:648:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:648:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL1:648:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL1:648:EDES NPP MS")
  field(INPB, "XCOR:COL1:648:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL1:808:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL1:808:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL1:808:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL1:808:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL1:808:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL1:808:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL1:808:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL1:808:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL1:808:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL1:808:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL1:808:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL1:808:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL1:808:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL1:808:EDES.PROC PP")
    field(LNK2, "XCOR:COL1:808:EACT.PROC PP")
    field(LNK3, "XCOR:COL1:808:EERR.DISA PP")
    field(LNK4, "XCOR:COL1:808:ECON.PROC PP")
    field(LNK5, "XCOR:COL1:808:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL1:808:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL1:808:BLEM.PROC PP")
    field(LNK8, "XCOR:COL1:808:BMOD.PROC PP")
    field(LNK9, "XCOR:COL1:808:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL1:808:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL1:808:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL1:808:BMAX")
  field(DOL2, "XCOR:COL1:808:BMAX")
  field(DOL3, "XCOR:COL1:808:BMAX")
  field(DOL4, "XCOR:COL1:808:BMIN")
  field(DOL5, "XCOR:COL1:808:BMIN")
  field(DOL6, "XCOR:COL1:808:BMIN")
  field(LNK1, "XCOR:COL1:808:BMAGX.HOPR")
  field(LNK2, "XCOR:COL1:808:BMAGY.HOPR")
  field(LNK3, "XCOR:COL1:808:BLEM.HOPR")
  field(LNK4, "XCOR:COL1:808:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL1:808:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL1:808:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:808:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:808:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL1:808:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL1:808:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL1:808:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:808:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:808:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:808:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:808:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:808:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL1:808:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL1:808:EDES NPP MS")
  field(INPB, "XCOR:COL1:808:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:COL1:968:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "XCOR:COL1:968:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:COL1:968:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:COL1:968:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:COL1:968:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:COL1:968:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:COL1:968:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:COL1:968:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:COL1:968:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:COL1:968:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:COL1:968:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:COL1:968:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:COL1:968:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:COL1:968:EDES.PROC PP")
    field(LNK2, "XCOR:COL1:968:EACT.PROC PP")
    field(LNK3, "XCOR:COL1:968:EERR.DISA PP")
    field(LNK4, "XCOR:COL1:968:ECON.PROC PP")
    field(LNK5, "XCOR:COL1:968:BMAGX.PROC PP")
    field(LNK6, "XCOR:COL1:968:BMAGY.PROC PP")
    field(LNK7, "XCOR:COL1:968:BLEM.PROC PP")
    field(LNK8, "XCOR:COL1:968:BMOD.PROC PP")
    field(LNK9, "XCOR:COL1:968:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:COL1:968:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:COL1:968:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:COL1:968:BMAX")
  field(DOL2, "XCOR:COL1:968:BMAX")
  field(DOL3, "XCOR:COL1:968:BMAX")
  field(DOL4, "XCOR:COL1:968:BMIN")
  field(DOL5, "XCOR:COL1:968:BMIN")
  field(DOL6, "XCOR:COL1:968:BMIN")
  field(LNK1, "XCOR:COL1:968:BMAGX.HOPR")
  field(LNK2, "XCOR:COL1:968:BMAGY.HOPR")
  field(LNK3, "XCOR:COL1:968:BLEM.HOPR")
  field(LNK4, "XCOR:COL1:968:BMAGX.LOPR PP")
  field(LNK5, "XCOR:COL1:968:BMAGY.LOPR PP")
  field(LNK6, "XCOR:COL1:968:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:968:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:COL1:968:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:COL1:968:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:COL1:968:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:COL1:968:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:968:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:968:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:968:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:COL1:968:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:COL1:968:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:COL1:968:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:COL1:968:EDES NPP MS")
  field(INPB, "XCOR:COL1:968:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL1:129:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL1:129:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL1:129:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL1:129:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL1:129:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL1:129:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL1:129:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL1:129:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL1:129:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL1:129:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL1:129:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL1:129:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL1:129:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL1:129:EDES.PROC PP")
    field(LNK2, "YCOR:COL1:129:EACT.PROC PP")
    field(LNK3, "YCOR:COL1:129:EERR.DISA PP")
    field(LNK4, "YCOR:COL1:129:ECON.PROC PP")
    field(LNK5, "YCOR:COL1:129:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL1:129:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL1:129:BLEM.PROC PP")
    field(LNK8, "YCOR:COL1:129:BMOD.PROC PP")
    field(LNK9, "YCOR:COL1:129:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL1:129:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL1:129:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL1:129:BMAX")
  field(DOL2, "YCOR:COL1:129:BMAX")
  field(DOL3, "YCOR:COL1:129:BMAX")
  field(DOL4, "YCOR:COL1:129:BMIN")
  field(DOL5, "YCOR:COL1:129:BMIN")
  field(DOL6, "YCOR:COL1:129:BMIN")
  field(LNK1, "YCOR:COL1:129:BMAGX.HOPR")
  field(LNK2, "YCOR:COL1:129:BMAGY.HOPR")
  field(LNK3, "YCOR:COL1:129:BLEM.HOPR")
  field(LNK4, "YCOR:COL1:129:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL1:129:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL1:129:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:129:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:129:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL1:129:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL1:129:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL1:129:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:129:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:129:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:129:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:129:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:129:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL1:129:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL1:129:EDES NPP MS")
  field(INPB, "YCOR:COL1:129:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL1:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL1:409:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL1:409:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL1:409:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL1:409:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL1:409:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL1:409:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL1:409:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL1:409:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL1:409:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL1:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL1:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL1:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL1:409:EDES.PROC PP")
    field(LNK2, "YCOR:COL1:409:EACT.PROC PP")
    field(LNK3, "YCOR:COL1:409:EERR.DISA PP")
    field(LNK4, "YCOR:COL1:409:ECON.PROC PP")
    field(LNK5, "YCOR:COL1:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL1:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL1:409:BLEM.PROC PP")
    field(LNK8, "YCOR:COL1:409:BMOD.PROC PP")
    field(LNK9, "YCOR:COL1:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL1:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL1:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL1:409:BMAX")
  field(DOL2, "YCOR:COL1:409:BMAX")
  field(DOL3, "YCOR:COL1:409:BMAX")
  field(DOL4, "YCOR:COL1:409:BMIN")
  field(DOL5, "YCOR:COL1:409:BMIN")
  field(DOL6, "YCOR:COL1:409:BMIN")
  field(LNK1, "YCOR:COL1:409:BMAGX.HOPR")
  field(LNK2, "YCOR:COL1:409:BMAGY.HOPR")
  field(LNK3, "YCOR:COL1:409:BLEM.HOPR")
  field(LNK4, "YCOR:COL1:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL1:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL1:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL1:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL1:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL1:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL1:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL1:409:EDES NPP MS")
  field(INPB, "YCOR:COL1:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL1:569:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL1:569:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL1:569:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL1:569:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL1:569:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL1:569:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL1:569:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL1:569:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL1:569:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL1:569:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL1:569:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL1:569:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL1:569:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL1:569:EDES.PROC PP")
    field(LNK2, "YCOR:COL1:569:EACT.PROC PP")
    field(LNK3, "YCOR:COL1:569:EERR.DISA PP")
    field(LNK4, "YCOR:COL1:569:ECON.PROC PP")
    field(LNK5, "YCOR:COL1:569:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL1:569:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL1:569:BLEM.PROC PP")
    field(LNK8, "YCOR:COL1:569:BMOD.PROC PP")
    field(LNK9, "YCOR:COL1:569:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL1:569:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL1:569:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL1:569:BMAX")
  field(DOL2, "YCOR:COL1:569:BMAX")
  field(DOL3, "YCOR:COL1:569:BMAX")
  field(DOL4, "YCOR:COL1:569:BMIN")
  field(DOL5, "YCOR:COL1:569:BMIN")
  field(DOL6, "YCOR:COL1:569:BMIN")
  field(LNK1, "YCOR:COL1:569:BMAGX.HOPR")
  field(LNK2, "YCOR:COL1:569:BMAGY.HOPR")
  field(LNK3, "YCOR:COL1:569:BLEM.HOPR")
  field(LNK4, "YCOR:COL1:569:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL1:569:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL1:569:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:569:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:569:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL1:569:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL1:569:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL1:569:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:569:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:569:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:569:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:569:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:569:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL1:569:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL1:569:EDES NPP MS")
  field(INPB, "YCOR:COL1:569:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL1:729:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL1:729:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL1:729:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL1:729:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL1:729:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL1:729:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL1:729:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL1:729:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL1:729:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL1:729:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL1:729:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL1:729:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL1:729:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL1:729:EDES.PROC PP")
    field(LNK2, "YCOR:COL1:729:EACT.PROC PP")
    field(LNK3, "YCOR:COL1:729:EERR.DISA PP")
    field(LNK4, "YCOR:COL1:729:ECON.PROC PP")
    field(LNK5, "YCOR:COL1:729:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL1:729:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL1:729:BLEM.PROC PP")
    field(LNK8, "YCOR:COL1:729:BMOD.PROC PP")
    field(LNK9, "YCOR:COL1:729:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL1:729:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL1:729:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL1:729:BMAX")
  field(DOL2, "YCOR:COL1:729:BMAX")
  field(DOL3, "YCOR:COL1:729:BMAX")
  field(DOL4, "YCOR:COL1:729:BMIN")
  field(DOL5, "YCOR:COL1:729:BMIN")
  field(DOL6, "YCOR:COL1:729:BMIN")
  field(LNK1, "YCOR:COL1:729:BMAGX.HOPR")
  field(LNK2, "YCOR:COL1:729:BMAGY.HOPR")
  field(LNK3, "YCOR:COL1:729:BLEM.HOPR")
  field(LNK4, "YCOR:COL1:729:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL1:729:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL1:729:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:729:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:729:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL1:729:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL1:729:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL1:729:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:729:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:729:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:729:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:729:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:729:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL1:729:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL1:729:EDES NPP MS")
  field(INPB, "YCOR:COL1:729:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:COL1:889:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L1B:1:CTRL.RVAL")
  field(LNK1, "YCOR:COL1:889:FUNC CA PP")
  field(DOL2, "MGNT:L1B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:COL1:889:FUNC CA PP")
  field(DOL3, "MGNT:L1B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:COL1:889:FUNC CA PP")
  field(DOL4, "MGNT:L1B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:COL1:889:FUNC CA PP")
  field(DOL5, "MGNT:L1B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:COL1:889:FUNC CA PP")
  field(DOL6, "MGNT:L1B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:COL1:889:FUNC CA PP")
  field(DOL7, "MGNT:L1B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:COL1:889:FUNC CA PP")
  field(DOL8, "MGNT:L1B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:COL1:889:FUNC CA PP")
  field(DOL9, "MGNT:L1B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:COL1:889:FUNC CA PP")
  field(DOLA, "MGNT:L1B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:COL1:889:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:COL1:889:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:COL1:889:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:COL1:889:EDES.PROC PP")
    field(LNK2, "YCOR:COL1:889:EACT.PROC PP")
    field(LNK3, "YCOR:COL1:889:EERR.DISA PP")
    field(LNK4, "YCOR:COL1:889:ECON.PROC PP")
    field(LNK5, "YCOR:COL1:889:BMAGX.PROC PP")
    field(LNK6, "YCOR:COL1:889:BMAGY.PROC PP")
    field(LNK7, "YCOR:COL1:889:BLEM.PROC PP")
    field(LNK8, "YCOR:COL1:889:BMOD.PROC PP")
    field(LNK9, "YCOR:COL1:889:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:COL1:889:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:COL1:889:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:COL1:889:BMAX")
  field(DOL2, "YCOR:COL1:889:BMAX")
  field(DOL3, "YCOR:COL1:889:BMAX")
  field(DOL4, "YCOR:COL1:889:BMIN")
  field(DOL5, "YCOR:COL1:889:BMIN")
  field(DOL6, "YCOR:COL1:889:BMIN")
  field(LNK1, "YCOR:COL1:889:BMAGX.HOPR")
  field(LNK2, "YCOR:COL1:889:BMAGY.HOPR")
  field(LNK3, "YCOR:COL1:889:BLEM.HOPR")
  field(LNK4, "YCOR:COL1:889:BMAGX.LOPR PP")
  field(LNK5, "YCOR:COL1:889:BMAGY.LOPR PP")
  field(LNK6, "YCOR:COL1:889:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:889:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:COL1:889:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:COL1:889:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:COL1:889:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:COL1:889:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:889:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:889:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:889:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:COL1:889:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:COL1:889:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:COL1:889:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:COL1:889:EDES NPP MS")
  field(INPB, "YCOR:COL1:889:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:0485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:0485:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:0485:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:0485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:0485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:0485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:0485:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:0485:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:0485:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:0485:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:0485:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:0485:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:0485:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:0485:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:0485:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:0485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:0485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:0485:BMAX")
  field(DOL2, "QUAD:L2B:0485:BMAX")
  field(DOL3, "QUAD:L2B:0485:BMAX")
  field(DOL4, "QUAD:L2B:0485:BMIN")
  field(DOL5, "QUAD:L2B:0485:BMIN")
  field(DOL6, "QUAD:L2B:0485:BMIN")
  field(LNK1, "QUAD:L2B:0485:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:0485:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:0485:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:0485:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:0485:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:0485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:0485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:0485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:0485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:0485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:0485:EDES NPP MS")
  field(INPB, "QUAD:L2B:0485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:0485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:0485:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:0485:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:0485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:0485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:0485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:0485:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:0485:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:0485:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:0485:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:0485:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:0485:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:0485:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:0485:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:0485:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:0485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:0485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:0485:BMAX")
  field(DOL2, "XCOR:L2B:0485:BMAX")
  field(DOL3, "XCOR:L2B:0485:BMAX")
  field(DOL4, "XCOR:L2B:0485:BMIN")
  field(DOL5, "XCOR:L2B:0485:BMIN")
  field(DOL6, "XCOR:L2B:0485:BMIN")
  field(LNK1, "XCOR:L2B:0485:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:0485:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:0485:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:0485:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:0485:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:0485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:0485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:0485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:0485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:0485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:0485:EDES NPP MS")
  field(INPB, "XCOR:L2B:0485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:0485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:0485:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:0485:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:0485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:0485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:0485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:0485:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:0485:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:0485:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:0485:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:0485:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:0485:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:0485:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:0485:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:0485:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:0485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:0485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:0485:BMAX")
  field(DOL2, "YCOR:L2B:0485:BMAX")
  field(DOL3, "YCOR:L2B:0485:BMAX")
  field(DOL4, "YCOR:L2B:0485:BMIN")
  field(DOL5, "YCOR:L2B:0485:BMIN")
  field(DOL6, "YCOR:L2B:0485:BMIN")
  field(LNK1, "YCOR:L2B:0485:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:0485:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:0485:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:0485:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:0485:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:0485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:0485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:0485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:0485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:0485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:0485:EDES NPP MS")
  field(INPB, "YCOR:L2B:0485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:0585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:0585:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:0585:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:0585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:0585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:0585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:0585:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:0585:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:0585:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:0585:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:0585:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:0585:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:0585:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:0585:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:0585:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:0585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:0585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:0585:BMAX")
  field(DOL2, "QUAD:L2B:0585:BMAX")
  field(DOL3, "QUAD:L2B:0585:BMAX")
  field(DOL4, "QUAD:L2B:0585:BMIN")
  field(DOL5, "QUAD:L2B:0585:BMIN")
  field(DOL6, "QUAD:L2B:0585:BMIN")
  field(LNK1, "QUAD:L2B:0585:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:0585:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:0585:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:0585:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:0585:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:0585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:0585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:0585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:0585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:0585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:0585:EDES NPP MS")
  field(INPB, "QUAD:L2B:0585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:0585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:0585:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:0585:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:0585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:0585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:0585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:0585:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:0585:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:0585:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:0585:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:0585:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:0585:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:0585:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:0585:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:0585:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:0585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:0585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:0585:BMAX")
  field(DOL2, "XCOR:L2B:0585:BMAX")
  field(DOL3, "XCOR:L2B:0585:BMAX")
  field(DOL4, "XCOR:L2B:0585:BMIN")
  field(DOL5, "XCOR:L2B:0585:BMIN")
  field(DOL6, "XCOR:L2B:0585:BMIN")
  field(LNK1, "XCOR:L2B:0585:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:0585:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:0585:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:0585:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:0585:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:0585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:0585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:0585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:0585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:0585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:0585:EDES NPP MS")
  field(INPB, "XCOR:L2B:0585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:0585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:0585:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:0585:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:0585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:0585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:0585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:0585:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:0585:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:0585:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:0585:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:0585:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:0585:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:0585:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:0585:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:0585:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:0585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:0585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:0585:BMAX")
  field(DOL2, "YCOR:L2B:0585:BMAX")
  field(DOL3, "YCOR:L2B:0585:BMAX")
  field(DOL4, "YCOR:L2B:0585:BMIN")
  field(DOL5, "YCOR:L2B:0585:BMIN")
  field(DOL6, "YCOR:L2B:0585:BMIN")
  field(LNK1, "YCOR:L2B:0585:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:0585:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:0585:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:0585:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:0585:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:0585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:0585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:0585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:0585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:0585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:0585:EDES NPP MS")
  field(INPB, "YCOR:L2B:0585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:0685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:0685:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:0685:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:0685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:0685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:0685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:0685:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:0685:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:0685:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:0685:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:0685:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:0685:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:0685:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:0685:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:0685:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:0685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:0685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:0685:BMAX")
  field(DOL2, "QUAD:L2B:0685:BMAX")
  field(DOL3, "QUAD:L2B:0685:BMAX")
  field(DOL4, "QUAD:L2B:0685:BMIN")
  field(DOL5, "QUAD:L2B:0685:BMIN")
  field(DOL6, "QUAD:L2B:0685:BMIN")
  field(LNK1, "QUAD:L2B:0685:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:0685:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:0685:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:0685:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:0685:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:0685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:0685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:0685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:0685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:0685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:0685:EDES NPP MS")
  field(INPB, "QUAD:L2B:0685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:0685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:0685:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:0685:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:0685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:0685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:0685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:0685:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:0685:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:0685:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:0685:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:0685:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:0685:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:0685:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:0685:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:0685:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:0685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:0685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:0685:BMAX")
  field(DOL2, "XCOR:L2B:0685:BMAX")
  field(DOL3, "XCOR:L2B:0685:BMAX")
  field(DOL4, "XCOR:L2B:0685:BMIN")
  field(DOL5, "XCOR:L2B:0685:BMIN")
  field(DOL6, "XCOR:L2B:0685:BMIN")
  field(LNK1, "XCOR:L2B:0685:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:0685:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:0685:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:0685:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:0685:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:0685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:0685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:0685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:0685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:0685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:0685:EDES NPP MS")
  field(INPB, "XCOR:L2B:0685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:0685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:0685:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:0685:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:0685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:0685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:0685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:0685:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:0685:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:0685:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:0685:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:0685:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:0685:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:0685:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:0685:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:0685:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:0685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:0685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:0685:BMAX")
  field(DOL2, "YCOR:L2B:0685:BMAX")
  field(DOL3, "YCOR:L2B:0685:BMAX")
  field(DOL4, "YCOR:L2B:0685:BMIN")
  field(DOL5, "YCOR:L2B:0685:BMIN")
  field(DOL6, "YCOR:L2B:0685:BMIN")
  field(LNK1, "YCOR:L2B:0685:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:0685:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:0685:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:0685:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:0685:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:0685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:0685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:0685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:0685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:0685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:0685:EDES NPP MS")
  field(INPB, "YCOR:L2B:0685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:0785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:0785:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:0785:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:0785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:0785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:0785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:0785:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:0785:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:0785:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:0785:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:0785:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:0785:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:0785:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:0785:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:0785:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:0785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:0785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:0785:BMAX")
  field(DOL2, "QUAD:L2B:0785:BMAX")
  field(DOL3, "QUAD:L2B:0785:BMAX")
  field(DOL4, "QUAD:L2B:0785:BMIN")
  field(DOL5, "QUAD:L2B:0785:BMIN")
  field(DOL6, "QUAD:L2B:0785:BMIN")
  field(LNK1, "QUAD:L2B:0785:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:0785:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:0785:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:0785:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:0785:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:0785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:0785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:0785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:0785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:0785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:0785:EDES NPP MS")
  field(INPB, "QUAD:L2B:0785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:0785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:0785:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:0785:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:0785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:0785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:0785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:0785:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:0785:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:0785:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:0785:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:0785:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:0785:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:0785:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:0785:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:0785:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:0785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:0785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:0785:BMAX")
  field(DOL2, "XCOR:L2B:0785:BMAX")
  field(DOL3, "XCOR:L2B:0785:BMAX")
  field(DOL4, "XCOR:L2B:0785:BMIN")
  field(DOL5, "XCOR:L2B:0785:BMIN")
  field(DOL6, "XCOR:L2B:0785:BMIN")
  field(LNK1, "XCOR:L2B:0785:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:0785:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:0785:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:0785:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:0785:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:0785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:0785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:0785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:0785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:0785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:0785:EDES NPP MS")
  field(INPB, "XCOR:L2B:0785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:0785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:0785:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:0785:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:0785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:0785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:0785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:0785:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:0785:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:0785:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:0785:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:0785:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:0785:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:0785:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:0785:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:0785:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:0785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:0785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:0785:BMAX")
  field(DOL2, "YCOR:L2B:0785:BMAX")
  field(DOL3, "YCOR:L2B:0785:BMAX")
  field(DOL4, "YCOR:L2B:0785:BMIN")
  field(DOL5, "YCOR:L2B:0785:BMIN")
  field(DOL6, "YCOR:L2B:0785:BMIN")
  field(LNK1, "YCOR:L2B:0785:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:0785:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:0785:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:0785:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:0785:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:0785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:0785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:0785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:0785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:0785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:0785:EDES NPP MS")
  field(INPB, "YCOR:L2B:0785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:0885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:0885:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:0885:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:0885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:0885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:0885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:0885:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:0885:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:0885:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:0885:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:0885:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:0885:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:0885:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:0885:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:0885:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:0885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:0885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:0885:BMAX")
  field(DOL2, "QUAD:L2B:0885:BMAX")
  field(DOL3, "QUAD:L2B:0885:BMAX")
  field(DOL4, "QUAD:L2B:0885:BMIN")
  field(DOL5, "QUAD:L2B:0885:BMIN")
  field(DOL6, "QUAD:L2B:0885:BMIN")
  field(LNK1, "QUAD:L2B:0885:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:0885:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:0885:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:0885:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:0885:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:0885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:0885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:0885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:0885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:0885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:0885:EDES NPP MS")
  field(INPB, "QUAD:L2B:0885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:0885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:0885:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:0885:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:0885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:0885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:0885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:0885:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:0885:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:0885:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:0885:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:0885:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:0885:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:0885:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:0885:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:0885:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:0885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:0885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:0885:BMAX")
  field(DOL2, "XCOR:L2B:0885:BMAX")
  field(DOL3, "XCOR:L2B:0885:BMAX")
  field(DOL4, "XCOR:L2B:0885:BMIN")
  field(DOL5, "XCOR:L2B:0885:BMIN")
  field(DOL6, "XCOR:L2B:0885:BMIN")
  field(LNK1, "XCOR:L2B:0885:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:0885:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:0885:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:0885:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:0885:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:0885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:0885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:0885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:0885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:0885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:0885:EDES NPP MS")
  field(INPB, "XCOR:L2B:0885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:0885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:0885:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:0885:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:0885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:0885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:0885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:0885:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:0885:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:0885:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:0885:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:0885:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:0885:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:0885:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:0885:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:0885:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:0885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:0885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:0885:BMAX")
  field(DOL2, "YCOR:L2B:0885:BMAX")
  field(DOL3, "YCOR:L2B:0885:BMAX")
  field(DOL4, "YCOR:L2B:0885:BMIN")
  field(DOL5, "YCOR:L2B:0885:BMIN")
  field(DOL6, "YCOR:L2B:0885:BMIN")
  field(LNK1, "YCOR:L2B:0885:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:0885:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:0885:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:0885:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:0885:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:0885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:0885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:0885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:0885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:0885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:0885:EDES NPP MS")
  field(INPB, "YCOR:L2B:0885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:0985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:0985:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:0985:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:0985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:0985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:0985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:0985:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:0985:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:0985:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:0985:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:0985:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:0985:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:0985:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:0985:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:0985:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:0985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:0985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:0985:BMAX")
  field(DOL2, "QUAD:L2B:0985:BMAX")
  field(DOL3, "QUAD:L2B:0985:BMAX")
  field(DOL4, "QUAD:L2B:0985:BMIN")
  field(DOL5, "QUAD:L2B:0985:BMIN")
  field(DOL6, "QUAD:L2B:0985:BMIN")
  field(LNK1, "QUAD:L2B:0985:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:0985:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:0985:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:0985:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:0985:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:0985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:0985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:0985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:0985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:0985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:0985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:0985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:0985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:0985:EDES NPP MS")
  field(INPB, "QUAD:L2B:0985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:0985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:0985:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:0985:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:0985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:0985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:0985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:0985:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:0985:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:0985:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:0985:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:0985:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:0985:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:0985:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:0985:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:0985:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:0985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:0985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:0985:BMAX")
  field(DOL2, "XCOR:L2B:0985:BMAX")
  field(DOL3, "XCOR:L2B:0985:BMAX")
  field(DOL4, "XCOR:L2B:0985:BMIN")
  field(DOL5, "XCOR:L2B:0985:BMIN")
  field(DOL6, "XCOR:L2B:0985:BMIN")
  field(LNK1, "XCOR:L2B:0985:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:0985:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:0985:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:0985:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:0985:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:0985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:0985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:0985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:0985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:0985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:0985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:0985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:0985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:0985:EDES NPP MS")
  field(INPB, "XCOR:L2B:0985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:0985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:0985:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:0985:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:0985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:0985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:0985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:0985:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:0985:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:0985:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:0985:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:0985:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:0985:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:0985:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:0985:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:0985:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:0985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:0985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:0985:BMAX")
  field(DOL2, "YCOR:L2B:0985:BMAX")
  field(DOL3, "YCOR:L2B:0985:BMAX")
  field(DOL4, "YCOR:L2B:0985:BMIN")
  field(DOL5, "YCOR:L2B:0985:BMIN")
  field(DOL6, "YCOR:L2B:0985:BMIN")
  field(LNK1, "YCOR:L2B:0985:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:0985:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:0985:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:0985:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:0985:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:0985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:0985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:0985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:0985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:0985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:0985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:0985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:0985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:0985:EDES NPP MS")
  field(INPB, "YCOR:L2B:0985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:1085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:1085:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:1085:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:1085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:1085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:1085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:1085:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:1085:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:1085:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:1085:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:1085:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:1085:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:1085:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:1085:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:1085:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:1085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:1085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:1085:BMAX")
  field(DOL2, "QUAD:L2B:1085:BMAX")
  field(DOL3, "QUAD:L2B:1085:BMAX")
  field(DOL4, "QUAD:L2B:1085:BMIN")
  field(DOL5, "QUAD:L2B:1085:BMIN")
  field(DOL6, "QUAD:L2B:1085:BMIN")
  field(LNK1, "QUAD:L2B:1085:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:1085:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:1085:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:1085:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:1085:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:1085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:1085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:1085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:1085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:1085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:1085:EDES NPP MS")
  field(INPB, "QUAD:L2B:1085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:1085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:1085:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:1085:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:1085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:1085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:1085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:1085:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:1085:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:1085:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:1085:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:1085:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:1085:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:1085:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:1085:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:1085:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:1085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:1085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:1085:BMAX")
  field(DOL2, "XCOR:L2B:1085:BMAX")
  field(DOL3, "XCOR:L2B:1085:BMAX")
  field(DOL4, "XCOR:L2B:1085:BMIN")
  field(DOL5, "XCOR:L2B:1085:BMIN")
  field(DOL6, "XCOR:L2B:1085:BMIN")
  field(LNK1, "XCOR:L2B:1085:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:1085:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:1085:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:1085:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:1085:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:1085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:1085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:1085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:1085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:1085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:1085:EDES NPP MS")
  field(INPB, "XCOR:L2B:1085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:1085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:1085:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:1085:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:1085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:1085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:1085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:1085:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:1085:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:1085:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:1085:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:1085:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:1085:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:1085:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:1085:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:1085:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:1085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:1085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:1085:BMAX")
  field(DOL2, "YCOR:L2B:1085:BMAX")
  field(DOL3, "YCOR:L2B:1085:BMAX")
  field(DOL4, "YCOR:L2B:1085:BMIN")
  field(DOL5, "YCOR:L2B:1085:BMIN")
  field(DOL6, "YCOR:L2B:1085:BMIN")
  field(LNK1, "YCOR:L2B:1085:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:1085:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:1085:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:1085:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:1085:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:1085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:1085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:1085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:1085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:1085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:1085:EDES NPP MS")
  field(INPB, "YCOR:L2B:1085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:1185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:1185:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:1185:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:1185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:1185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:1185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:1185:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:1185:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:1185:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:1185:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:1185:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:1185:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:1185:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:1185:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:1185:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:1185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:1185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:1185:BMAX")
  field(DOL2, "QUAD:L2B:1185:BMAX")
  field(DOL3, "QUAD:L2B:1185:BMAX")
  field(DOL4, "QUAD:L2B:1185:BMIN")
  field(DOL5, "QUAD:L2B:1185:BMIN")
  field(DOL6, "QUAD:L2B:1185:BMIN")
  field(LNK1, "QUAD:L2B:1185:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:1185:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:1185:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:1185:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:1185:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:1185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:1185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:1185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:1185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:1185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:1185:EDES NPP MS")
  field(INPB, "QUAD:L2B:1185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:1185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:1185:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:1185:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:1185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:1185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:1185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:1185:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:1185:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:1185:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:1185:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:1185:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:1185:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:1185:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:1185:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:1185:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:1185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:1185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:1185:BMAX")
  field(DOL2, "XCOR:L2B:1185:BMAX")
  field(DOL3, "XCOR:L2B:1185:BMAX")
  field(DOL4, "XCOR:L2B:1185:BMIN")
  field(DOL5, "XCOR:L2B:1185:BMIN")
  field(DOL6, "XCOR:L2B:1185:BMIN")
  field(LNK1, "XCOR:L2B:1185:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:1185:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:1185:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:1185:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:1185:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:1185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:1185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:1185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:1185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:1185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:1185:EDES NPP MS")
  field(INPB, "XCOR:L2B:1185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:1185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:1185:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:1185:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:1185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:1185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:1185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:1185:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:1185:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:1185:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:1185:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:1185:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:1185:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:1185:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:1185:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:1185:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:1185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:1185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:1185:BMAX")
  field(DOL2, "YCOR:L2B:1185:BMAX")
  field(DOL3, "YCOR:L2B:1185:BMAX")
  field(DOL4, "YCOR:L2B:1185:BMIN")
  field(DOL5, "YCOR:L2B:1185:BMIN")
  field(DOL6, "YCOR:L2B:1185:BMIN")
  field(LNK1, "YCOR:L2B:1185:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:1185:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:1185:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:1185:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:1185:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:1185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:1185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:1185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:1185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:1185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:1185:EDES NPP MS")
  field(INPB, "YCOR:L2B:1185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:1285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:1285:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:1285:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:1285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:1285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:1285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:1285:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:1285:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:1285:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:1285:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:1285:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:1285:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:1285:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:1285:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:1285:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:1285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:1285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:1285:BMAX")
  field(DOL2, "QUAD:L2B:1285:BMAX")
  field(DOL3, "QUAD:L2B:1285:BMAX")
  field(DOL4, "QUAD:L2B:1285:BMIN")
  field(DOL5, "QUAD:L2B:1285:BMIN")
  field(DOL6, "QUAD:L2B:1285:BMIN")
  field(LNK1, "QUAD:L2B:1285:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:1285:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:1285:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:1285:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:1285:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:1285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:1285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:1285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:1285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:1285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:1285:EDES NPP MS")
  field(INPB, "QUAD:L2B:1285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:1285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:1285:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:1285:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:1285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:1285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:1285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:1285:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:1285:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:1285:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:1285:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:1285:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:1285:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:1285:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:1285:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:1285:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:1285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:1285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:1285:BMAX")
  field(DOL2, "XCOR:L2B:1285:BMAX")
  field(DOL3, "XCOR:L2B:1285:BMAX")
  field(DOL4, "XCOR:L2B:1285:BMIN")
  field(DOL5, "XCOR:L2B:1285:BMIN")
  field(DOL6, "XCOR:L2B:1285:BMIN")
  field(LNK1, "XCOR:L2B:1285:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:1285:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:1285:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:1285:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:1285:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:1285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:1285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:1285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:1285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:1285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:1285:EDES NPP MS")
  field(INPB, "XCOR:L2B:1285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:1285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:1285:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:1285:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:1285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:1285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:1285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:1285:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:1285:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:1285:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:1285:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:1285:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:1285:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:1285:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:1285:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:1285:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:1285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:1285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:1285:BMAX")
  field(DOL2, "YCOR:L2B:1285:BMAX")
  field(DOL3, "YCOR:L2B:1285:BMAX")
  field(DOL4, "YCOR:L2B:1285:BMIN")
  field(DOL5, "YCOR:L2B:1285:BMIN")
  field(DOL6, "YCOR:L2B:1285:BMIN")
  field(LNK1, "YCOR:L2B:1285:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:1285:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:1285:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:1285:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:1285:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:1285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:1285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:1285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:1285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:1285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:1285:EDES NPP MS")
  field(INPB, "YCOR:L2B:1285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:1385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:1385:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:1385:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:1385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:1385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:1385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:1385:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:1385:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:1385:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:1385:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:1385:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:1385:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:1385:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:1385:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:1385:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:1385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:1385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:1385:BMAX")
  field(DOL2, "QUAD:L2B:1385:BMAX")
  field(DOL3, "QUAD:L2B:1385:BMAX")
  field(DOL4, "QUAD:L2B:1385:BMIN")
  field(DOL5, "QUAD:L2B:1385:BMIN")
  field(DOL6, "QUAD:L2B:1385:BMIN")
  field(LNK1, "QUAD:L2B:1385:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:1385:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:1385:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:1385:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:1385:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:1385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:1385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:1385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:1385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:1385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:1385:EDES NPP MS")
  field(INPB, "QUAD:L2B:1385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:1385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:1385:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:1385:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:1385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:1385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:1385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:1385:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:1385:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:1385:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:1385:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:1385:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:1385:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:1385:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:1385:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:1385:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:1385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:1385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:1385:BMAX")
  field(DOL2, "XCOR:L2B:1385:BMAX")
  field(DOL3, "XCOR:L2B:1385:BMAX")
  field(DOL4, "XCOR:L2B:1385:BMIN")
  field(DOL5, "XCOR:L2B:1385:BMIN")
  field(DOL6, "XCOR:L2B:1385:BMIN")
  field(LNK1, "XCOR:L2B:1385:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:1385:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:1385:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:1385:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:1385:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:1385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:1385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:1385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:1385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:1385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:1385:EDES NPP MS")
  field(INPB, "XCOR:L2B:1385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:1385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:1385:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:1385:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:1385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:1385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:1385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:1385:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:1385:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:1385:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:1385:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:1385:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:1385:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:1385:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:1385:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:1385:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:1385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:1385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:1385:BMAX")
  field(DOL2, "YCOR:L2B:1385:BMAX")
  field(DOL3, "YCOR:L2B:1385:BMAX")
  field(DOL4, "YCOR:L2B:1385:BMIN")
  field(DOL5, "YCOR:L2B:1385:BMIN")
  field(DOL6, "YCOR:L2B:1385:BMIN")
  field(LNK1, "YCOR:L2B:1385:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:1385:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:1385:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:1385:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:1385:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:1385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:1385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:1385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:1385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:1385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:1385:EDES NPP MS")
  field(INPB, "YCOR:L2B:1385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:1485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:1485:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:1485:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:1485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:1485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:1485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:1485:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:1485:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:1485:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:1485:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:1485:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:1485:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:1485:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:1485:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:1485:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:1485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:1485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:1485:BMAX")
  field(DOL2, "QUAD:L2B:1485:BMAX")
  field(DOL3, "QUAD:L2B:1485:BMAX")
  field(DOL4, "QUAD:L2B:1485:BMIN")
  field(DOL5, "QUAD:L2B:1485:BMIN")
  field(DOL6, "QUAD:L2B:1485:BMIN")
  field(LNK1, "QUAD:L2B:1485:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:1485:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:1485:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:1485:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:1485:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:1485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:1485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:1485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:1485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:1485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:1485:EDES NPP MS")
  field(INPB, "QUAD:L2B:1485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:1485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:1485:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:1485:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:1485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:1485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:1485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:1485:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:1485:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:1485:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:1485:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:1485:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:1485:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:1485:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:1485:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:1485:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:1485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:1485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:1485:BMAX")
  field(DOL2, "XCOR:L2B:1485:BMAX")
  field(DOL3, "XCOR:L2B:1485:BMAX")
  field(DOL4, "XCOR:L2B:1485:BMIN")
  field(DOL5, "XCOR:L2B:1485:BMIN")
  field(DOL6, "XCOR:L2B:1485:BMIN")
  field(LNK1, "XCOR:L2B:1485:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:1485:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:1485:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:1485:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:1485:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:1485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:1485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:1485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:1485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:1485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:1485:EDES NPP MS")
  field(INPB, "XCOR:L2B:1485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:1485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:1485:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:1485:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:1485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:1485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:1485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:1485:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:1485:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:1485:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:1485:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:1485:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:1485:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:1485:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:1485:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:1485:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:1485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:1485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:1485:BMAX")
  field(DOL2, "YCOR:L2B:1485:BMAX")
  field(DOL3, "YCOR:L2B:1485:BMAX")
  field(DOL4, "YCOR:L2B:1485:BMIN")
  field(DOL5, "YCOR:L2B:1485:BMIN")
  field(DOL6, "YCOR:L2B:1485:BMIN")
  field(LNK1, "YCOR:L2B:1485:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:1485:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:1485:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:1485:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:1485:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:1485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:1485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:1485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:1485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:1485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:1485:EDES NPP MS")
  field(INPB, "YCOR:L2B:1485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L2B:1585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L2B:1585:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L2B:1585:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L2B:1585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L2B:1585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L2B:1585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L2B:1585:EDES.PROC PP")
    field(LNK2, "QUAD:L2B:1585:EACT.PROC PP")
    field(LNK3, "QUAD:L2B:1585:EERR.DISA PP")
    field(LNK4, "QUAD:L2B:1585:ECON.PROC PP")
    field(LNK5, "QUAD:L2B:1585:BMAGX.PROC PP")
    field(LNK6, "QUAD:L2B:1585:BMAGY.PROC PP")
    field(LNK7, "QUAD:L2B:1585:BLEM.PROC PP")
    field(LNK8, "QUAD:L2B:1585:BMOD.PROC PP")
    field(LNK9, "QUAD:L2B:1585:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L2B:1585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L2B:1585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L2B:1585:BMAX")
  field(DOL2, "QUAD:L2B:1585:BMAX")
  field(DOL3, "QUAD:L2B:1585:BMAX")
  field(DOL4, "QUAD:L2B:1585:BMIN")
  field(DOL5, "QUAD:L2B:1585:BMIN")
  field(DOL6, "QUAD:L2B:1585:BMIN")
  field(LNK1, "QUAD:L2B:1585:BMAGX.HOPR")
  field(LNK2, "QUAD:L2B:1585:BMAGY.HOPR")
  field(LNK3, "QUAD:L2B:1585:BLEM.HOPR")
  field(LNK4, "QUAD:L2B:1585:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L2B:1585:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L2B:1585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L2B:1585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L2B:1585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L2B:1585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L2B:1585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L2B:1585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L2B:1585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L2B:1585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L2B:1585:EDES NPP MS")
  field(INPB, "QUAD:L2B:1585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L2B:1585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L2B:1585:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L2B:1585:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L2B:1585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L2B:1585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L2B:1585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L2B:1585:EDES.PROC PP")
    field(LNK2, "XCOR:L2B:1585:EACT.PROC PP")
    field(LNK3, "XCOR:L2B:1585:EERR.DISA PP")
    field(LNK4, "XCOR:L2B:1585:ECON.PROC PP")
    field(LNK5, "XCOR:L2B:1585:BMAGX.PROC PP")
    field(LNK6, "XCOR:L2B:1585:BMAGY.PROC PP")
    field(LNK7, "XCOR:L2B:1585:BLEM.PROC PP")
    field(LNK8, "XCOR:L2B:1585:BMOD.PROC PP")
    field(LNK9, "XCOR:L2B:1585:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L2B:1585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L2B:1585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L2B:1585:BMAX")
  field(DOL2, "XCOR:L2B:1585:BMAX")
  field(DOL3, "XCOR:L2B:1585:BMAX")
  field(DOL4, "XCOR:L2B:1585:BMIN")
  field(DOL5, "XCOR:L2B:1585:BMIN")
  field(DOL6, "XCOR:L2B:1585:BMIN")
  field(LNK1, "XCOR:L2B:1585:BMAGX.HOPR")
  field(LNK2, "XCOR:L2B:1585:BMAGY.HOPR")
  field(LNK3, "XCOR:L2B:1585:BLEM.HOPR")
  field(LNK4, "XCOR:L2B:1585:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L2B:1585:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L2B:1585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L2B:1585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L2B:1585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L2B:1585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L2B:1585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L2B:1585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L2B:1585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L2B:1585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L2B:1585:EDES NPP MS")
  field(INPB, "XCOR:L2B:1585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L2B:1585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL2, "MGNT:L2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL3, "MGNT:L2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL4, "MGNT:L2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL5, "MGNT:L2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL6, "MGNT:L2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL7, "MGNT:L2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL8, "MGNT:L2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L2B:1585:FUNC CA PP")
  field(DOL9, "MGNT:L2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L2B:1585:FUNC CA PP")
  field(DOLA, "MGNT:L2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L2B:1585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L2B:1585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L2B:1585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L2B:1585:EDES.PROC PP")
    field(LNK2, "YCOR:L2B:1585:EACT.PROC PP")
    field(LNK3, "YCOR:L2B:1585:EERR.DISA PP")
    field(LNK4, "YCOR:L2B:1585:ECON.PROC PP")
    field(LNK5, "YCOR:L2B:1585:BMAGX.PROC PP")
    field(LNK6, "YCOR:L2B:1585:BMAGY.PROC PP")
    field(LNK7, "YCOR:L2B:1585:BLEM.PROC PP")
    field(LNK8, "YCOR:L2B:1585:BMOD.PROC PP")
    field(LNK9, "YCOR:L2B:1585:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L2B:1585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L2B:1585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L2B:1585:BMAX")
  field(DOL2, "YCOR:L2B:1585:BMAX")
  field(DOL3, "YCOR:L2B:1585:BMAX")
  field(DOL4, "YCOR:L2B:1585:BMIN")
  field(DOL5, "YCOR:L2B:1585:BMIN")
  field(DOL6, "YCOR:L2B:1585:BMIN")
  field(LNK1, "YCOR:L2B:1585:BMAGX.HOPR")
  field(LNK2, "YCOR:L2B:1585:BMAGY.HOPR")
  field(LNK3, "YCOR:L2B:1585:BLEM.HOPR")
  field(LNK4, "YCOR:L2B:1585:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L2B:1585:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L2B:1585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L2B:1585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L2B:1585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L2B:1585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L2B:1585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L2B:1585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L2B:1585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L2B:1585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L2B:1585:EDES NPP MS")
  field(INPB, "YCOR:L2B:1585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC2B:500:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC2B:500:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC2B:500:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC2B:500:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC2B:500:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC2B:500:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC2B:500:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC2B:500:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC2B:500:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC2B:500:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC2B:500:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC2B:500:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC2B:500:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC2B:500:EDES.PROC PP")
    field(LNK2, "BEND:BC2B:500:EACT.PROC PP")
    field(LNK3, "BEND:BC2B:500:EERR.DISA PP")
    field(LNK4, "BEND:BC2B:500:ECON.PROC PP")
    field(LNK5, "BEND:BC2B:500:BMAGX.PROC PP")
    field(LNK6, "BEND:BC2B:500:BMAGY.PROC PP")
    field(LNK7, "BEND:BC2B:500:BLEM.PROC PP")
    field(LNK8, "BEND:BC2B:500:BMOD.PROC PP")
    field(LNK9, "BEND:BC2B:500:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC2B:500:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC2B:500:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC2B:500:BMAX")
  field(DOL2, "BEND:BC2B:500:BMAX")
  field(DOL3, "BEND:BC2B:500:BMAX")
  field(DOL4, "BEND:BC2B:500:BMIN")
  field(DOL5, "BEND:BC2B:500:BMIN")
  field(DOL6, "BEND:BC2B:500:BMIN")
  field(LNK1, "BEND:BC2B:500:BMAGX.HOPR")
  field(LNK2, "BEND:BC2B:500:BMAGY.HOPR")
  field(LNK3, "BEND:BC2B:500:BLEM.HOPR")
  field(LNK4, "BEND:BC2B:500:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC2B:500:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC2B:500:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:500:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:500:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC2B:500:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC2B:500:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC2B:500:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:500:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:500:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:BC2B:500:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:500:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:BC2B:500:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC2B:500:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC2B:500:EDES NPP MS")
  field(INPB, "BEND:BC2B:500:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:BC2B:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:BC2B:200:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:BC2B:200:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:BC2B:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:BC2B:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:BC2B:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:BC2B:200:EDES.PROC PP")
    field(LNK2, "BTRM:BC2B:200:EACT.PROC PP")
    field(LNK3, "BTRM:BC2B:200:EERR.DISA PP")
    field(LNK4, "BTRM:BC2B:200:ECON.PROC PP")
    field(LNK5, "BTRM:BC2B:200:BMAGX.PROC PP")
    field(LNK6, "BTRM:BC2B:200:BMAGY.PROC PP")
    field(LNK7, "BTRM:BC2B:200:BLEM.PROC PP")
    field(LNK8, "BTRM:BC2B:200:BMOD.PROC PP")
    field(LNK9, "BTRM:BC2B:200:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:BC2B:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:BC2B:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:BC2B:200:BMAX")
  field(DOL2, "BTRM:BC2B:200:BMAX")
  field(DOL3, "BTRM:BC2B:200:BMAX")
  field(DOL4, "BTRM:BC2B:200:BMIN")
  field(DOL5, "BTRM:BC2B:200:BMIN")
  field(DOL6, "BTRM:BC2B:200:BMIN")
  field(LNK1, "BTRM:BC2B:200:BMAGX.HOPR")
  field(LNK2, "BTRM:BC2B:200:BMAGY.HOPR")
  field(LNK3, "BTRM:BC2B:200:BLEM.HOPR")
  field(LNK4, "BTRM:BC2B:200:BMAGX.LOPR PP")
  field(LNK5, "BTRM:BC2B:200:BMAGY.LOPR PP")
  field(LNK6, "BTRM:BC2B:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:BC2B:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:BC2B:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:BC2B:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:BC2B:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:BC2B:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC2B:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC2B:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:BC2B:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:BC2B:200:EDES NPP MS")
  field(INPB, "BTRM:BC2B:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:BC2B:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:BC2B:600:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:BC2B:600:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:BC2B:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:BC2B:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:BC2B:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:BC2B:600:EDES.PROC PP")
    field(LNK2, "BTRM:BC2B:600:EACT.PROC PP")
    field(LNK3, "BTRM:BC2B:600:EERR.DISA PP")
    field(LNK4, "BTRM:BC2B:600:ECON.PROC PP")
    field(LNK5, "BTRM:BC2B:600:BMAGX.PROC PP")
    field(LNK6, "BTRM:BC2B:600:BMAGY.PROC PP")
    field(LNK7, "BTRM:BC2B:600:BLEM.PROC PP")
    field(LNK8, "BTRM:BC2B:600:BMOD.PROC PP")
    field(LNK9, "BTRM:BC2B:600:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:BC2B:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:BC2B:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:BC2B:600:BMAX")
  field(DOL2, "BTRM:BC2B:600:BMAX")
  field(DOL3, "BTRM:BC2B:600:BMAX")
  field(DOL4, "BTRM:BC2B:600:BMIN")
  field(DOL5, "BTRM:BC2B:600:BMIN")
  field(DOL6, "BTRM:BC2B:600:BMIN")
  field(LNK1, "BTRM:BC2B:600:BMAGX.HOPR")
  field(LNK2, "BTRM:BC2B:600:BMAGY.HOPR")
  field(LNK3, "BTRM:BC2B:600:BLEM.HOPR")
  field(LNK4, "BTRM:BC2B:600:BMAGX.LOPR PP")
  field(LNK5, "BTRM:BC2B:600:BMAGY.LOPR PP")
  field(LNK6, "BTRM:BC2B:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:BC2B:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:BC2B:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:BC2B:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:BC2B:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:BC2B:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC2B:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC2B:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:BC2B:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:BC2B:600:EDES NPP MS")
  field(INPB, "BTRM:BC2B:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:BC2B:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:BC2B:900:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:BC2B:900:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:BC2B:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:BC2B:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:BC2B:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:BC2B:900:EDES.PROC PP")
    field(LNK2, "BTRM:BC2B:900:EACT.PROC PP")
    field(LNK3, "BTRM:BC2B:900:EERR.DISA PP")
    field(LNK4, "BTRM:BC2B:900:ECON.PROC PP")
    field(LNK5, "BTRM:BC2B:900:BMAGX.PROC PP")
    field(LNK6, "BTRM:BC2B:900:BMAGY.PROC PP")
    field(LNK7, "BTRM:BC2B:900:BLEM.PROC PP")
    field(LNK8, "BTRM:BC2B:900:BMOD.PROC PP")
    field(LNK9, "BTRM:BC2B:900:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:BC2B:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:BC2B:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:BC2B:900:BMAX")
  field(DOL2, "BTRM:BC2B:900:BMAX")
  field(DOL3, "BTRM:BC2B:900:BMAX")
  field(DOL4, "BTRM:BC2B:900:BMIN")
  field(DOL5, "BTRM:BC2B:900:BMIN")
  field(DOL6, "BTRM:BC2B:900:BMIN")
  field(LNK1, "BTRM:BC2B:900:BMAGX.HOPR")
  field(LNK2, "BTRM:BC2B:900:BMAGY.HOPR")
  field(LNK3, "BTRM:BC2B:900:BLEM.HOPR")
  field(LNK4, "BTRM:BC2B:900:BMAGX.LOPR PP")
  field(LNK5, "BTRM:BC2B:900:BMAGY.LOPR PP")
  field(LNK6, "BTRM:BC2B:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:BC2B:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:BC2B:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:BC2B:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:BC2B:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:BC2B:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC2B:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:BC2B:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:BC2B:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:BC2B:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:BC2B:900:EDES NPP MS")
  field(INPB, "BTRM:BC2B:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BC2B:150:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BC2B:150:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BC2B:150:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BC2B:150:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BC2B:150:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BC2B:150:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BC2B:150:EDES.PROC PP")
    field(LNK2, "QUAD:BC2B:150:EACT.PROC PP")
    field(LNK3, "QUAD:BC2B:150:EERR.DISA PP")
    field(LNK4, "QUAD:BC2B:150:ECON.PROC PP")
    field(LNK5, "QUAD:BC2B:150:BMAGX.PROC PP")
    field(LNK6, "QUAD:BC2B:150:BMAGY.PROC PP")
    field(LNK7, "QUAD:BC2B:150:BLEM.PROC PP")
    field(LNK8, "QUAD:BC2B:150:BMOD.PROC PP")
    field(LNK9, "QUAD:BC2B:150:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BC2B:150:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BC2B:150:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BC2B:150:BMAX")
  field(DOL2, "QUAD:BC2B:150:BMAX")
  field(DOL3, "QUAD:BC2B:150:BMAX")
  field(DOL4, "QUAD:BC2B:150:BMIN")
  field(DOL5, "QUAD:BC2B:150:BMIN")
  field(DOL6, "QUAD:BC2B:150:BMIN")
  field(LNK1, "QUAD:BC2B:150:BMAGX.HOPR")
  field(LNK2, "QUAD:BC2B:150:BMAGY.HOPR")
  field(LNK3, "QUAD:BC2B:150:BLEM.HOPR")
  field(LNK4, "QUAD:BC2B:150:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BC2B:150:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BC2B:150:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BC2B:150:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BC2B:150:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BC2B:150:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BC2B:150:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BC2B:150:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:150:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:150:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC2B:150:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:150:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC2B:150:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BC2B:150:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BC2B:150:EDES NPP MS")
  field(INPB, "QUAD:BC2B:150:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BC2B:250:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BC2B:250:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BC2B:250:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BC2B:250:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BC2B:250:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BC2B:250:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BC2B:250:EDES.PROC PP")
    field(LNK2, "QUAD:BC2B:250:EACT.PROC PP")
    field(LNK3, "QUAD:BC2B:250:EERR.DISA PP")
    field(LNK4, "QUAD:BC2B:250:ECON.PROC PP")
    field(LNK5, "QUAD:BC2B:250:BMAGX.PROC PP")
    field(LNK6, "QUAD:BC2B:250:BMAGY.PROC PP")
    field(LNK7, "QUAD:BC2B:250:BLEM.PROC PP")
    field(LNK8, "QUAD:BC2B:250:BMOD.PROC PP")
    field(LNK9, "QUAD:BC2B:250:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BC2B:250:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BC2B:250:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BC2B:250:BMAX")
  field(DOL2, "QUAD:BC2B:250:BMAX")
  field(DOL3, "QUAD:BC2B:250:BMAX")
  field(DOL4, "QUAD:BC2B:250:BMIN")
  field(DOL5, "QUAD:BC2B:250:BMIN")
  field(DOL6, "QUAD:BC2B:250:BMIN")
  field(LNK1, "QUAD:BC2B:250:BMAGX.HOPR")
  field(LNK2, "QUAD:BC2B:250:BMAGY.HOPR")
  field(LNK3, "QUAD:BC2B:250:BLEM.HOPR")
  field(LNK4, "QUAD:BC2B:250:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BC2B:250:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BC2B:250:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BC2B:250:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BC2B:250:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BC2B:250:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BC2B:250:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BC2B:250:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:250:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:250:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC2B:250:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:250:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC2B:250:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BC2B:250:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BC2B:250:EDES NPP MS")
  field(INPB, "QUAD:BC2B:250:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BC2B:850:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BC2B:850:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BC2B:850:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BC2B:850:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BC2B:850:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BC2B:850:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BC2B:850:EDES.PROC PP")
    field(LNK2, "QUAD:BC2B:850:EACT.PROC PP")
    field(LNK3, "QUAD:BC2B:850:EERR.DISA PP")
    field(LNK4, "QUAD:BC2B:850:ECON.PROC PP")
    field(LNK5, "QUAD:BC2B:850:BMAGX.PROC PP")
    field(LNK6, "QUAD:BC2B:850:BMAGY.PROC PP")
    field(LNK7, "QUAD:BC2B:850:BLEM.PROC PP")
    field(LNK8, "QUAD:BC2B:850:BMOD.PROC PP")
    field(LNK9, "QUAD:BC2B:850:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BC2B:850:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BC2B:850:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BC2B:850:BMAX")
  field(DOL2, "QUAD:BC2B:850:BMAX")
  field(DOL3, "QUAD:BC2B:850:BMAX")
  field(DOL4, "QUAD:BC2B:850:BMIN")
  field(DOL5, "QUAD:BC2B:850:BMIN")
  field(DOL6, "QUAD:BC2B:850:BMIN")
  field(LNK1, "QUAD:BC2B:850:BMAGX.HOPR")
  field(LNK2, "QUAD:BC2B:850:BMAGY.HOPR")
  field(LNK3, "QUAD:BC2B:850:BLEM.HOPR")
  field(LNK4, "QUAD:BC2B:850:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BC2B:850:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BC2B:850:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BC2B:850:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BC2B:850:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BC2B:850:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BC2B:850:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BC2B:850:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:850:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:850:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC2B:850:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BC2B:850:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BC2B:850:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BC2B:850:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BC2B:850:EDES NPP MS")
  field(INPB, "QUAD:BC2B:850:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BC2B:126:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BC2B:126:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BC2B:126:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BC2B:126:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BC2B:126:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BC2B:126:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BC2B:126:EDES.PROC PP")
    field(LNK2, "XCOR:BC2B:126:EACT.PROC PP")
    field(LNK3, "XCOR:BC2B:126:EERR.DISA PP")
    field(LNK4, "XCOR:BC2B:126:ECON.PROC PP")
    field(LNK5, "XCOR:BC2B:126:BMAGX.PROC PP")
    field(LNK6, "XCOR:BC2B:126:BMAGY.PROC PP")
    field(LNK7, "XCOR:BC2B:126:BLEM.PROC PP")
    field(LNK8, "XCOR:BC2B:126:BMOD.PROC PP")
    field(LNK9, "XCOR:BC2B:126:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BC2B:126:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BC2B:126:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BC2B:126:BMAX")
  field(DOL2, "XCOR:BC2B:126:BMAX")
  field(DOL3, "XCOR:BC2B:126:BMAX")
  field(DOL4, "XCOR:BC2B:126:BMIN")
  field(DOL5, "XCOR:BC2B:126:BMIN")
  field(DOL6, "XCOR:BC2B:126:BMIN")
  field(LNK1, "XCOR:BC2B:126:BMAGX.HOPR")
  field(LNK2, "XCOR:BC2B:126:BMAGY.HOPR")
  field(LNK3, "XCOR:BC2B:126:BLEM.HOPR")
  field(LNK4, "XCOR:BC2B:126:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BC2B:126:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BC2B:126:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BC2B:126:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BC2B:126:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BC2B:126:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BC2B:126:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BC2B:126:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC2B:126:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC2B:126:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BC2B:126:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BC2B:126:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BC2B:126:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BC2B:126:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BC2B:126:EDES NPP MS")
  field(INPB, "XCOR:BC2B:126:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BC2B:137:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BC2B:137:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BC2B:137:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BC2B:137:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BC2B:137:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BC2B:137:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BC2B:137:EDES.PROC PP")
    field(LNK2, "YCOR:BC2B:137:EACT.PROC PP")
    field(LNK3, "YCOR:BC2B:137:EERR.DISA PP")
    field(LNK4, "YCOR:BC2B:137:ECON.PROC PP")
    field(LNK5, "YCOR:BC2B:137:BMAGX.PROC PP")
    field(LNK6, "YCOR:BC2B:137:BMAGY.PROC PP")
    field(LNK7, "YCOR:BC2B:137:BLEM.PROC PP")
    field(LNK8, "YCOR:BC2B:137:BMOD.PROC PP")
    field(LNK9, "YCOR:BC2B:137:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BC2B:137:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BC2B:137:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BC2B:137:BMAX")
  field(DOL2, "YCOR:BC2B:137:BMAX")
  field(DOL3, "YCOR:BC2B:137:BMAX")
  field(DOL4, "YCOR:BC2B:137:BMIN")
  field(DOL5, "YCOR:BC2B:137:BMIN")
  field(DOL6, "YCOR:BC2B:137:BMIN")
  field(LNK1, "YCOR:BC2B:137:BMAGX.HOPR")
  field(LNK2, "YCOR:BC2B:137:BMAGY.HOPR")
  field(LNK3, "YCOR:BC2B:137:BLEM.HOPR")
  field(LNK4, "YCOR:BC2B:137:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BC2B:137:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BC2B:137:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BC2B:137:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BC2B:137:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BC2B:137:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BC2B:137:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BC2B:137:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC2B:137:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC2B:137:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BC2B:137:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BC2B:137:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BC2B:137:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BC2B:137:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BC2B:137:EDES NPP MS")
  field(INPB, "YCOR:BC2B:137:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:EMIT2:150:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:EMIT2:150:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:EMIT2:150:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:EMIT2:150:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:EMIT2:150:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:EMIT2:150:EDES.PROC PP")
    field(LNK2, "QUAD:EMIT2:150:EACT.PROC PP")
    field(LNK3, "QUAD:EMIT2:150:EERR.DISA PP")
    field(LNK4, "QUAD:EMIT2:150:ECON.PROC PP")
    field(LNK5, "QUAD:EMIT2:150:BMAGX.PROC PP")
    field(LNK6, "QUAD:EMIT2:150:BMAGY.PROC PP")
    field(LNK7, "QUAD:EMIT2:150:BLEM.PROC PP")
    field(LNK8, "QUAD:EMIT2:150:BMOD.PROC PP")
    field(LNK9, "QUAD:EMIT2:150:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:EMIT2:150:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:EMIT2:150:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:EMIT2:150:BMAX")
  field(DOL2, "QUAD:EMIT2:150:BMAX")
  field(DOL3, "QUAD:EMIT2:150:BMAX")
  field(DOL4, "QUAD:EMIT2:150:BMIN")
  field(DOL5, "QUAD:EMIT2:150:BMIN")
  field(DOL6, "QUAD:EMIT2:150:BMIN")
  field(LNK1, "QUAD:EMIT2:150:BMAGX.HOPR")
  field(LNK2, "QUAD:EMIT2:150:BMAGY.HOPR")
  field(LNK3, "QUAD:EMIT2:150:BLEM.HOPR")
  field(LNK4, "QUAD:EMIT2:150:BMAGX.LOPR PP")
  field(LNK5, "QUAD:EMIT2:150:BMAGY.LOPR PP")
  field(LNK6, "QUAD:EMIT2:150:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:150:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:150:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:EMIT2:150:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:EMIT2:150:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:EMIT2:150:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:150:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:150:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:150:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:150:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:150:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:EMIT2:150:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:EMIT2:150:EDES NPP MS")
  field(INPB, "QUAD:EMIT2:150:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:EMIT2:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:EMIT2:300:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:EMIT2:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:EMIT2:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:EMIT2:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:EMIT2:300:EDES.PROC PP")
    field(LNK2, "QUAD:EMIT2:300:EACT.PROC PP")
    field(LNK3, "QUAD:EMIT2:300:EERR.DISA PP")
    field(LNK4, "QUAD:EMIT2:300:ECON.PROC PP")
    field(LNK5, "QUAD:EMIT2:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:EMIT2:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:EMIT2:300:BLEM.PROC PP")
    field(LNK8, "QUAD:EMIT2:300:BMOD.PROC PP")
    field(LNK9, "QUAD:EMIT2:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:EMIT2:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:EMIT2:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:EMIT2:300:BMAX")
  field(DOL2, "QUAD:EMIT2:300:BMAX")
  field(DOL3, "QUAD:EMIT2:300:BMAX")
  field(DOL4, "QUAD:EMIT2:300:BMIN")
  field(DOL5, "QUAD:EMIT2:300:BMIN")
  field(DOL6, "QUAD:EMIT2:300:BMIN")
  field(LNK1, "QUAD:EMIT2:300:BMAGX.HOPR")
  field(LNK2, "QUAD:EMIT2:300:BMAGY.HOPR")
  field(LNK3, "QUAD:EMIT2:300:BLEM.HOPR")
  field(LNK4, "QUAD:EMIT2:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:EMIT2:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:EMIT2:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:EMIT2:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:EMIT2:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:EMIT2:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:EMIT2:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:EMIT2:300:EDES NPP MS")
  field(INPB, "QUAD:EMIT2:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:EMIT2:800:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:EMIT2:800:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:EMIT2:800:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:EMIT2:800:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:EMIT2:800:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:EMIT2:800:EDES.PROC PP")
    field(LNK2, "QUAD:EMIT2:800:EACT.PROC PP")
    field(LNK3, "QUAD:EMIT2:800:EERR.DISA PP")
    field(LNK4, "QUAD:EMIT2:800:ECON.PROC PP")
    field(LNK5, "QUAD:EMIT2:800:BMAGX.PROC PP")
    field(LNK6, "QUAD:EMIT2:800:BMAGY.PROC PP")
    field(LNK7, "QUAD:EMIT2:800:BLEM.PROC PP")
    field(LNK8, "QUAD:EMIT2:800:BMOD.PROC PP")
    field(LNK9, "QUAD:EMIT2:800:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:EMIT2:800:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:EMIT2:800:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:EMIT2:800:BMAX")
  field(DOL2, "QUAD:EMIT2:800:BMAX")
  field(DOL3, "QUAD:EMIT2:800:BMAX")
  field(DOL4, "QUAD:EMIT2:800:BMIN")
  field(DOL5, "QUAD:EMIT2:800:BMIN")
  field(DOL6, "QUAD:EMIT2:800:BMIN")
  field(LNK1, "QUAD:EMIT2:800:BMAGX.HOPR")
  field(LNK2, "QUAD:EMIT2:800:BMAGY.HOPR")
  field(LNK3, "QUAD:EMIT2:800:BLEM.HOPR")
  field(LNK4, "QUAD:EMIT2:800:BMAGX.LOPR PP")
  field(LNK5, "QUAD:EMIT2:800:BMAGY.LOPR PP")
  field(LNK6, "QUAD:EMIT2:800:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:800:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:800:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:EMIT2:800:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:EMIT2:800:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:EMIT2:800:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:800:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:800:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:800:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:800:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:800:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:EMIT2:800:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:EMIT2:800:EDES NPP MS")
  field(INPB, "QUAD:EMIT2:800:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:EMIT2:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:EMIT2:900:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:EMIT2:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:EMIT2:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:EMIT2:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:EMIT2:900:EDES.PROC PP")
    field(LNK2, "QUAD:EMIT2:900:EACT.PROC PP")
    field(LNK3, "QUAD:EMIT2:900:EERR.DISA PP")
    field(LNK4, "QUAD:EMIT2:900:ECON.PROC PP")
    field(LNK5, "QUAD:EMIT2:900:BMAGX.PROC PP")
    field(LNK6, "QUAD:EMIT2:900:BMAGY.PROC PP")
    field(LNK7, "QUAD:EMIT2:900:BLEM.PROC PP")
    field(LNK8, "QUAD:EMIT2:900:BMOD.PROC PP")
    field(LNK9, "QUAD:EMIT2:900:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:EMIT2:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:EMIT2:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:EMIT2:900:BMAX")
  field(DOL2, "QUAD:EMIT2:900:BMAX")
  field(DOL3, "QUAD:EMIT2:900:BMAX")
  field(DOL4, "QUAD:EMIT2:900:BMIN")
  field(DOL5, "QUAD:EMIT2:900:BMIN")
  field(DOL6, "QUAD:EMIT2:900:BMIN")
  field(LNK1, "QUAD:EMIT2:900:BMAGX.HOPR")
  field(LNK2, "QUAD:EMIT2:900:BMAGY.HOPR")
  field(LNK3, "QUAD:EMIT2:900:BLEM.HOPR")
  field(LNK4, "QUAD:EMIT2:900:BMAGX.LOPR PP")
  field(LNK5, "QUAD:EMIT2:900:BMAGY.LOPR PP")
  field(LNK6, "QUAD:EMIT2:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:EMIT2:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:EMIT2:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:EMIT2:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:EMIT2:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EMIT2:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EMIT2:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:EMIT2:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:EMIT2:900:EDES NPP MS")
  field(INPB, "QUAD:EMIT2:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:EMIT2:310:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:EMIT2:310:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:EMIT2:310:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:EMIT2:310:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:EMIT2:310:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:EMIT2:310:EDES.PROC PP")
    field(LNK2, "XCOR:EMIT2:310:EACT.PROC PP")
    field(LNK3, "XCOR:EMIT2:310:EERR.DISA PP")
    field(LNK4, "XCOR:EMIT2:310:ECON.PROC PP")
    field(LNK5, "XCOR:EMIT2:310:BMAGX.PROC PP")
    field(LNK6, "XCOR:EMIT2:310:BMAGY.PROC PP")
    field(LNK7, "XCOR:EMIT2:310:BLEM.PROC PP")
    field(LNK8, "XCOR:EMIT2:310:BMOD.PROC PP")
    field(LNK9, "XCOR:EMIT2:310:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:EMIT2:310:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:EMIT2:310:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:EMIT2:310:BMAX")
  field(DOL2, "XCOR:EMIT2:310:BMAX")
  field(DOL3, "XCOR:EMIT2:310:BMAX")
  field(DOL4, "XCOR:EMIT2:310:BMIN")
  field(DOL5, "XCOR:EMIT2:310:BMIN")
  field(DOL6, "XCOR:EMIT2:310:BMIN")
  field(LNK1, "XCOR:EMIT2:310:BMAGX.HOPR")
  field(LNK2, "XCOR:EMIT2:310:BMAGY.HOPR")
  field(LNK3, "XCOR:EMIT2:310:BLEM.HOPR")
  field(LNK4, "XCOR:EMIT2:310:BMAGX.LOPR PP")
  field(LNK5, "XCOR:EMIT2:310:BMAGY.LOPR PP")
  field(LNK6, "XCOR:EMIT2:310:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:EMIT2:310:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:EMIT2:310:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:EMIT2:310:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:EMIT2:310:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:EMIT2:310:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EMIT2:310:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EMIT2:310:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EMIT2:310:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EMIT2:310:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EMIT2:310:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:EMIT2:310:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:EMIT2:310:EDES NPP MS")
  field(INPB, "XCOR:EMIT2:310:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:EMIT2:912:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:EMIT2:912:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:EMIT2:912:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:EMIT2:912:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:EMIT2:912:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:EMIT2:912:EDES.PROC PP")
    field(LNK2, "XCOR:EMIT2:912:EACT.PROC PP")
    field(LNK3, "XCOR:EMIT2:912:EERR.DISA PP")
    field(LNK4, "XCOR:EMIT2:912:ECON.PROC PP")
    field(LNK5, "XCOR:EMIT2:912:BMAGX.PROC PP")
    field(LNK6, "XCOR:EMIT2:912:BMAGY.PROC PP")
    field(LNK7, "XCOR:EMIT2:912:BLEM.PROC PP")
    field(LNK8, "XCOR:EMIT2:912:BMOD.PROC PP")
    field(LNK9, "XCOR:EMIT2:912:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:EMIT2:912:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:EMIT2:912:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:EMIT2:912:BMAX")
  field(DOL2, "XCOR:EMIT2:912:BMAX")
  field(DOL3, "XCOR:EMIT2:912:BMAX")
  field(DOL4, "XCOR:EMIT2:912:BMIN")
  field(DOL5, "XCOR:EMIT2:912:BMIN")
  field(DOL6, "XCOR:EMIT2:912:BMIN")
  field(LNK1, "XCOR:EMIT2:912:BMAGX.HOPR")
  field(LNK2, "XCOR:EMIT2:912:BMAGY.HOPR")
  field(LNK3, "XCOR:EMIT2:912:BLEM.HOPR")
  field(LNK4, "XCOR:EMIT2:912:BMAGX.LOPR PP")
  field(LNK5, "XCOR:EMIT2:912:BMAGY.LOPR PP")
  field(LNK6, "XCOR:EMIT2:912:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:EMIT2:912:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:EMIT2:912:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:EMIT2:912:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:EMIT2:912:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:EMIT2:912:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EMIT2:912:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EMIT2:912:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EMIT2:912:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EMIT2:912:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EMIT2:912:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:EMIT2:912:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:EMIT2:912:EDES NPP MS")
  field(INPB, "XCOR:EMIT2:912:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:EMIT2:161:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:EMIT2:161:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:EMIT2:161:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:EMIT2:161:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:EMIT2:161:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:EMIT2:161:EDES.PROC PP")
    field(LNK2, "YCOR:EMIT2:161:EACT.PROC PP")
    field(LNK3, "YCOR:EMIT2:161:EERR.DISA PP")
    field(LNK4, "YCOR:EMIT2:161:ECON.PROC PP")
    field(LNK5, "YCOR:EMIT2:161:BMAGX.PROC PP")
    field(LNK6, "YCOR:EMIT2:161:BMAGY.PROC PP")
    field(LNK7, "YCOR:EMIT2:161:BLEM.PROC PP")
    field(LNK8, "YCOR:EMIT2:161:BMOD.PROC PP")
    field(LNK9, "YCOR:EMIT2:161:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:EMIT2:161:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:EMIT2:161:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:EMIT2:161:BMAX")
  field(DOL2, "YCOR:EMIT2:161:BMAX")
  field(DOL3, "YCOR:EMIT2:161:BMAX")
  field(DOL4, "YCOR:EMIT2:161:BMIN")
  field(DOL5, "YCOR:EMIT2:161:BMIN")
  field(DOL6, "YCOR:EMIT2:161:BMIN")
  field(LNK1, "YCOR:EMIT2:161:BMAGX.HOPR")
  field(LNK2, "YCOR:EMIT2:161:BMAGY.HOPR")
  field(LNK3, "YCOR:EMIT2:161:BLEM.HOPR")
  field(LNK4, "YCOR:EMIT2:161:BMAGX.LOPR PP")
  field(LNK5, "YCOR:EMIT2:161:BMAGY.LOPR PP")
  field(LNK6, "YCOR:EMIT2:161:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:EMIT2:161:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:EMIT2:161:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:EMIT2:161:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:EMIT2:161:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:EMIT2:161:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EMIT2:161:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EMIT2:161:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EMIT2:161:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EMIT2:161:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EMIT2:161:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:EMIT2:161:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:EMIT2:161:EDES NPP MS")
  field(INPB, "YCOR:EMIT2:161:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:EMIT2:811:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EMIT2:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EMIT2:1:CTRL.RVAL")
  field(LNK1, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL2, "MGNT:EMIT2:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL3, "MGNT:EMIT2:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL4, "MGNT:EMIT2:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL5, "MGNT:EMIT2:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL6, "MGNT:EMIT2:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL7, "MGNT:EMIT2:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL8, "MGNT:EMIT2:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOL9, "MGNT:EMIT2:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:EMIT2:811:FUNC CA PP")
  field(DOLA, "MGNT:EMIT2:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:EMIT2:811:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:EMIT2:811:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:EMIT2:811:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:EMIT2:811:EDES.PROC PP")
    field(LNK2, "YCOR:EMIT2:811:EACT.PROC PP")
    field(LNK3, "YCOR:EMIT2:811:EERR.DISA PP")
    field(LNK4, "YCOR:EMIT2:811:ECON.PROC PP")
    field(LNK5, "YCOR:EMIT2:811:BMAGX.PROC PP")
    field(LNK6, "YCOR:EMIT2:811:BMAGY.PROC PP")
    field(LNK7, "YCOR:EMIT2:811:BLEM.PROC PP")
    field(LNK8, "YCOR:EMIT2:811:BMOD.PROC PP")
    field(LNK9, "YCOR:EMIT2:811:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:EMIT2:811:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:EMIT2:811:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:EMIT2:811:BMAX")
  field(DOL2, "YCOR:EMIT2:811:BMAX")
  field(DOL3, "YCOR:EMIT2:811:BMAX")
  field(DOL4, "YCOR:EMIT2:811:BMIN")
  field(DOL5, "YCOR:EMIT2:811:BMIN")
  field(DOL6, "YCOR:EMIT2:811:BMIN")
  field(LNK1, "YCOR:EMIT2:811:BMAGX.HOPR")
  field(LNK2, "YCOR:EMIT2:811:BMAGY.HOPR")
  field(LNK3, "YCOR:EMIT2:811:BLEM.HOPR")
  field(LNK4, "YCOR:EMIT2:811:BMAGX.LOPR PP")
  field(LNK5, "YCOR:EMIT2:811:BMAGY.LOPR PP")
  field(LNK6, "YCOR:EMIT2:811:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:EMIT2:811:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:EMIT2:811:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:EMIT2:811:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:EMIT2:811:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:EMIT2:811:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EMIT2:811:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EMIT2:811:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EMIT2:811:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EMIT2:811:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EMIT2:811:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:EMIT2:811:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:EMIT2:811:EDES NPP MS")
  field(INPB, "YCOR:EMIT2:811:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:1685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:1685:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:1685:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:1685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:1685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:1685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:1685:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:1685:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:1685:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:1685:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:1685:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:1685:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:1685:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:1685:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:1685:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:1685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:1685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:1685:BMAX")
  field(DOL2, "QUAD:L3B:1685:BMAX")
  field(DOL3, "QUAD:L3B:1685:BMAX")
  field(DOL4, "QUAD:L3B:1685:BMIN")
  field(DOL5, "QUAD:L3B:1685:BMIN")
  field(DOL6, "QUAD:L3B:1685:BMIN")
  field(LNK1, "QUAD:L3B:1685:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:1685:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:1685:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:1685:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:1685:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:1685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:1685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:1685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:1685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:1685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:1685:EDES NPP MS")
  field(INPB, "QUAD:L3B:1685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:1685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:1685:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:1685:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:1685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:1685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:1685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:1685:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:1685:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:1685:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:1685:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:1685:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:1685:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:1685:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:1685:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:1685:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:1685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:1685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:1685:BMAX")
  field(DOL2, "XCOR:L3B:1685:BMAX")
  field(DOL3, "XCOR:L3B:1685:BMAX")
  field(DOL4, "XCOR:L3B:1685:BMIN")
  field(DOL5, "XCOR:L3B:1685:BMIN")
  field(DOL6, "XCOR:L3B:1685:BMIN")
  field(LNK1, "XCOR:L3B:1685:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:1685:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:1685:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:1685:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:1685:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:1685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:1685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:1685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:1685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:1685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:1685:EDES NPP MS")
  field(INPB, "XCOR:L3B:1685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:1685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:1685:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:1685:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:1685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:1685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:1685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:1685:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:1685:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:1685:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:1685:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:1685:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:1685:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:1685:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:1685:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:1685:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:1685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:1685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:1685:BMAX")
  field(DOL2, "YCOR:L3B:1685:BMAX")
  field(DOL3, "YCOR:L3B:1685:BMAX")
  field(DOL4, "YCOR:L3B:1685:BMIN")
  field(DOL5, "YCOR:L3B:1685:BMIN")
  field(DOL6, "YCOR:L3B:1685:BMIN")
  field(LNK1, "YCOR:L3B:1685:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:1685:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:1685:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:1685:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:1685:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:1685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:1685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:1685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:1685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:1685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:1685:EDES NPP MS")
  field(INPB, "YCOR:L3B:1685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:1785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:1785:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:1785:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:1785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:1785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:1785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:1785:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:1785:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:1785:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:1785:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:1785:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:1785:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:1785:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:1785:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:1785:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:1785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:1785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:1785:BMAX")
  field(DOL2, "QUAD:L3B:1785:BMAX")
  field(DOL3, "QUAD:L3B:1785:BMAX")
  field(DOL4, "QUAD:L3B:1785:BMIN")
  field(DOL5, "QUAD:L3B:1785:BMIN")
  field(DOL6, "QUAD:L3B:1785:BMIN")
  field(LNK1, "QUAD:L3B:1785:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:1785:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:1785:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:1785:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:1785:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:1785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:1785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:1785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:1785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:1785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:1785:EDES NPP MS")
  field(INPB, "QUAD:L3B:1785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:1785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:1785:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:1785:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:1785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:1785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:1785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:1785:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:1785:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:1785:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:1785:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:1785:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:1785:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:1785:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:1785:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:1785:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:1785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:1785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:1785:BMAX")
  field(DOL2, "XCOR:L3B:1785:BMAX")
  field(DOL3, "XCOR:L3B:1785:BMAX")
  field(DOL4, "XCOR:L3B:1785:BMIN")
  field(DOL5, "XCOR:L3B:1785:BMIN")
  field(DOL6, "XCOR:L3B:1785:BMIN")
  field(LNK1, "XCOR:L3B:1785:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:1785:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:1785:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:1785:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:1785:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:1785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:1785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:1785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:1785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:1785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:1785:EDES NPP MS")
  field(INPB, "XCOR:L3B:1785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:1785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:1785:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:1785:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:1785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:1785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:1785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:1785:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:1785:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:1785:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:1785:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:1785:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:1785:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:1785:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:1785:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:1785:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:1785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:1785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:1785:BMAX")
  field(DOL2, "YCOR:L3B:1785:BMAX")
  field(DOL3, "YCOR:L3B:1785:BMAX")
  field(DOL4, "YCOR:L3B:1785:BMIN")
  field(DOL5, "YCOR:L3B:1785:BMIN")
  field(DOL6, "YCOR:L3B:1785:BMIN")
  field(LNK1, "YCOR:L3B:1785:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:1785:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:1785:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:1785:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:1785:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:1785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:1785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:1785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:1785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:1785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:1785:EDES NPP MS")
  field(INPB, "YCOR:L3B:1785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:1885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:1885:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:1885:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:1885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:1885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:1885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:1885:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:1885:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:1885:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:1885:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:1885:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:1885:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:1885:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:1885:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:1885:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:1885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:1885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:1885:BMAX")
  field(DOL2, "QUAD:L3B:1885:BMAX")
  field(DOL3, "QUAD:L3B:1885:BMAX")
  field(DOL4, "QUAD:L3B:1885:BMIN")
  field(DOL5, "QUAD:L3B:1885:BMIN")
  field(DOL6, "QUAD:L3B:1885:BMIN")
  field(LNK1, "QUAD:L3B:1885:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:1885:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:1885:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:1885:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:1885:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:1885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:1885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:1885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:1885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:1885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:1885:EDES NPP MS")
  field(INPB, "QUAD:L3B:1885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:1885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:1885:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:1885:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:1885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:1885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:1885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:1885:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:1885:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:1885:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:1885:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:1885:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:1885:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:1885:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:1885:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:1885:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:1885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:1885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:1885:BMAX")
  field(DOL2, "XCOR:L3B:1885:BMAX")
  field(DOL3, "XCOR:L3B:1885:BMAX")
  field(DOL4, "XCOR:L3B:1885:BMIN")
  field(DOL5, "XCOR:L3B:1885:BMIN")
  field(DOL6, "XCOR:L3B:1885:BMIN")
  field(LNK1, "XCOR:L3B:1885:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:1885:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:1885:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:1885:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:1885:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:1885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:1885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:1885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:1885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:1885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:1885:EDES NPP MS")
  field(INPB, "XCOR:L3B:1885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:1885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:1885:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:1885:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:1885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:1885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:1885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:1885:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:1885:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:1885:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:1885:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:1885:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:1885:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:1885:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:1885:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:1885:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:1885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:1885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:1885:BMAX")
  field(DOL2, "YCOR:L3B:1885:BMAX")
  field(DOL3, "YCOR:L3B:1885:BMAX")
  field(DOL4, "YCOR:L3B:1885:BMIN")
  field(DOL5, "YCOR:L3B:1885:BMIN")
  field(DOL6, "YCOR:L3B:1885:BMIN")
  field(LNK1, "YCOR:L3B:1885:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:1885:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:1885:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:1885:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:1885:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:1885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:1885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:1885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:1885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:1885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:1885:EDES NPP MS")
  field(INPB, "YCOR:L3B:1885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:1985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:1985:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:1985:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:1985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:1985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:1985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:1985:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:1985:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:1985:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:1985:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:1985:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:1985:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:1985:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:1985:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:1985:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:1985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:1985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:1985:BMAX")
  field(DOL2, "QUAD:L3B:1985:BMAX")
  field(DOL3, "QUAD:L3B:1985:BMAX")
  field(DOL4, "QUAD:L3B:1985:BMIN")
  field(DOL5, "QUAD:L3B:1985:BMIN")
  field(DOL6, "QUAD:L3B:1985:BMIN")
  field(LNK1, "QUAD:L3B:1985:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:1985:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:1985:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:1985:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:1985:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:1985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:1985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:1985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:1985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:1985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:1985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:1985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:1985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:1985:EDES NPP MS")
  field(INPB, "QUAD:L3B:1985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:1985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:1985:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:1985:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:1985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:1985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:1985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:1985:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:1985:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:1985:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:1985:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:1985:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:1985:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:1985:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:1985:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:1985:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:1985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:1985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:1985:BMAX")
  field(DOL2, "XCOR:L3B:1985:BMAX")
  field(DOL3, "XCOR:L3B:1985:BMAX")
  field(DOL4, "XCOR:L3B:1985:BMIN")
  field(DOL5, "XCOR:L3B:1985:BMIN")
  field(DOL6, "XCOR:L3B:1985:BMIN")
  field(LNK1, "XCOR:L3B:1985:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:1985:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:1985:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:1985:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:1985:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:1985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:1985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:1985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:1985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:1985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:1985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:1985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:1985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:1985:EDES NPP MS")
  field(INPB, "XCOR:L3B:1985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:1985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:1985:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:1985:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:1985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:1985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:1985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:1985:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:1985:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:1985:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:1985:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:1985:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:1985:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:1985:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:1985:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:1985:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:1985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:1985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:1985:BMAX")
  field(DOL2, "YCOR:L3B:1985:BMAX")
  field(DOL3, "YCOR:L3B:1985:BMAX")
  field(DOL4, "YCOR:L3B:1985:BMIN")
  field(DOL5, "YCOR:L3B:1985:BMIN")
  field(DOL6, "YCOR:L3B:1985:BMIN")
  field(LNK1, "YCOR:L3B:1985:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:1985:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:1985:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:1985:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:1985:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:1985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:1985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:1985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:1985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:1985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:1985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:1985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:1985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:1985:EDES NPP MS")
  field(INPB, "YCOR:L3B:1985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2085:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2085:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2085:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2085:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2085:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2085:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2085:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2085:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2085:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2085:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2085:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2085:BMAX")
  field(DOL2, "QUAD:L3B:2085:BMAX")
  field(DOL3, "QUAD:L3B:2085:BMAX")
  field(DOL4, "QUAD:L3B:2085:BMIN")
  field(DOL5, "QUAD:L3B:2085:BMIN")
  field(DOL6, "QUAD:L3B:2085:BMIN")
  field(LNK1, "QUAD:L3B:2085:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2085:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2085:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2085:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2085:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2085:EDES NPP MS")
  field(INPB, "QUAD:L3B:2085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2085:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2085:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2085:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2085:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2085:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2085:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2085:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2085:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2085:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2085:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2085:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2085:BMAX")
  field(DOL2, "XCOR:L3B:2085:BMAX")
  field(DOL3, "XCOR:L3B:2085:BMAX")
  field(DOL4, "XCOR:L3B:2085:BMIN")
  field(DOL5, "XCOR:L3B:2085:BMIN")
  field(DOL6, "XCOR:L3B:2085:BMIN")
  field(LNK1, "XCOR:L3B:2085:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2085:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2085:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2085:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2085:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2085:EDES NPP MS")
  field(INPB, "XCOR:L3B:2085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2085:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2085:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2085:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2085:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2085:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2085:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2085:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2085:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2085:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2085:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2085:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2085:BMAX")
  field(DOL2, "YCOR:L3B:2085:BMAX")
  field(DOL3, "YCOR:L3B:2085:BMAX")
  field(DOL4, "YCOR:L3B:2085:BMIN")
  field(DOL5, "YCOR:L3B:2085:BMIN")
  field(DOL6, "YCOR:L3B:2085:BMIN")
  field(LNK1, "YCOR:L3B:2085:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2085:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2085:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2085:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2085:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2085:EDES NPP MS")
  field(INPB, "YCOR:L3B:2085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2185:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2185:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2185:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2185:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2185:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2185:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2185:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2185:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2185:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2185:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2185:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2185:BMAX")
  field(DOL2, "QUAD:L3B:2185:BMAX")
  field(DOL3, "QUAD:L3B:2185:BMAX")
  field(DOL4, "QUAD:L3B:2185:BMIN")
  field(DOL5, "QUAD:L3B:2185:BMIN")
  field(DOL6, "QUAD:L3B:2185:BMIN")
  field(LNK1, "QUAD:L3B:2185:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2185:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2185:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2185:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2185:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2185:EDES NPP MS")
  field(INPB, "QUAD:L3B:2185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2185:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2185:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2185:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2185:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2185:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2185:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2185:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2185:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2185:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2185:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2185:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2185:BMAX")
  field(DOL2, "XCOR:L3B:2185:BMAX")
  field(DOL3, "XCOR:L3B:2185:BMAX")
  field(DOL4, "XCOR:L3B:2185:BMIN")
  field(DOL5, "XCOR:L3B:2185:BMIN")
  field(DOL6, "XCOR:L3B:2185:BMIN")
  field(LNK1, "XCOR:L3B:2185:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2185:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2185:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2185:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2185:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2185:EDES NPP MS")
  field(INPB, "XCOR:L3B:2185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2185:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2185:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2185:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2185:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2185:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2185:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2185:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2185:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2185:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2185:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2185:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2185:BMAX")
  field(DOL2, "YCOR:L3B:2185:BMAX")
  field(DOL3, "YCOR:L3B:2185:BMAX")
  field(DOL4, "YCOR:L3B:2185:BMIN")
  field(DOL5, "YCOR:L3B:2185:BMIN")
  field(DOL6, "YCOR:L3B:2185:BMIN")
  field(LNK1, "YCOR:L3B:2185:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2185:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2185:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2185:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2185:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2185:EDES NPP MS")
  field(INPB, "YCOR:L3B:2185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2285:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2285:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2285:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2285:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2285:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2285:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2285:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2285:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2285:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2285:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2285:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2285:BMAX")
  field(DOL2, "QUAD:L3B:2285:BMAX")
  field(DOL3, "QUAD:L3B:2285:BMAX")
  field(DOL4, "QUAD:L3B:2285:BMIN")
  field(DOL5, "QUAD:L3B:2285:BMIN")
  field(DOL6, "QUAD:L3B:2285:BMIN")
  field(LNK1, "QUAD:L3B:2285:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2285:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2285:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2285:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2285:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2285:EDES NPP MS")
  field(INPB, "QUAD:L3B:2285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2285:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2285:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2285:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2285:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2285:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2285:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2285:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2285:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2285:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2285:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2285:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2285:BMAX")
  field(DOL2, "XCOR:L3B:2285:BMAX")
  field(DOL3, "XCOR:L3B:2285:BMAX")
  field(DOL4, "XCOR:L3B:2285:BMIN")
  field(DOL5, "XCOR:L3B:2285:BMIN")
  field(DOL6, "XCOR:L3B:2285:BMIN")
  field(LNK1, "XCOR:L3B:2285:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2285:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2285:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2285:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2285:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2285:EDES NPP MS")
  field(INPB, "XCOR:L3B:2285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2285:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2285:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2285:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2285:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2285:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2285:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2285:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2285:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2285:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2285:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2285:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2285:BMAX")
  field(DOL2, "YCOR:L3B:2285:BMAX")
  field(DOL3, "YCOR:L3B:2285:BMAX")
  field(DOL4, "YCOR:L3B:2285:BMIN")
  field(DOL5, "YCOR:L3B:2285:BMIN")
  field(DOL6, "YCOR:L3B:2285:BMIN")
  field(LNK1, "YCOR:L3B:2285:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2285:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2285:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2285:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2285:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2285:EDES NPP MS")
  field(INPB, "YCOR:L3B:2285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2385:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2385:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2385:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2385:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2385:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2385:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2385:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2385:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2385:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2385:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2385:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2385:BMAX")
  field(DOL2, "QUAD:L3B:2385:BMAX")
  field(DOL3, "QUAD:L3B:2385:BMAX")
  field(DOL4, "QUAD:L3B:2385:BMIN")
  field(DOL5, "QUAD:L3B:2385:BMIN")
  field(DOL6, "QUAD:L3B:2385:BMIN")
  field(LNK1, "QUAD:L3B:2385:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2385:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2385:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2385:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2385:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2385:EDES NPP MS")
  field(INPB, "QUAD:L3B:2385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2385:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2385:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2385:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2385:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2385:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2385:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2385:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2385:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2385:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2385:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2385:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2385:BMAX")
  field(DOL2, "XCOR:L3B:2385:BMAX")
  field(DOL3, "XCOR:L3B:2385:BMAX")
  field(DOL4, "XCOR:L3B:2385:BMIN")
  field(DOL5, "XCOR:L3B:2385:BMIN")
  field(DOL6, "XCOR:L3B:2385:BMIN")
  field(LNK1, "XCOR:L3B:2385:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2385:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2385:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2385:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2385:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2385:EDES NPP MS")
  field(INPB, "XCOR:L3B:2385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2385:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2385:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2385:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2385:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2385:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2385:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2385:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2385:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2385:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2385:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2385:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2385:BMAX")
  field(DOL2, "YCOR:L3B:2385:BMAX")
  field(DOL3, "YCOR:L3B:2385:BMAX")
  field(DOL4, "YCOR:L3B:2385:BMIN")
  field(DOL5, "YCOR:L3B:2385:BMIN")
  field(DOL6, "YCOR:L3B:2385:BMIN")
  field(LNK1, "YCOR:L3B:2385:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2385:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2385:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2385:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2385:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2385:EDES NPP MS")
  field(INPB, "YCOR:L3B:2385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2485:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2485:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2485:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2485:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2485:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2485:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2485:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2485:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2485:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2485:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2485:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2485:BMAX")
  field(DOL2, "QUAD:L3B:2485:BMAX")
  field(DOL3, "QUAD:L3B:2485:BMAX")
  field(DOL4, "QUAD:L3B:2485:BMIN")
  field(DOL5, "QUAD:L3B:2485:BMIN")
  field(DOL6, "QUAD:L3B:2485:BMIN")
  field(LNK1, "QUAD:L3B:2485:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2485:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2485:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2485:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2485:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2485:EDES NPP MS")
  field(INPB, "QUAD:L3B:2485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2485:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2485:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2485:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2485:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2485:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2485:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2485:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2485:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2485:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2485:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2485:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2485:BMAX")
  field(DOL2, "XCOR:L3B:2485:BMAX")
  field(DOL3, "XCOR:L3B:2485:BMAX")
  field(DOL4, "XCOR:L3B:2485:BMIN")
  field(DOL5, "XCOR:L3B:2485:BMIN")
  field(DOL6, "XCOR:L3B:2485:BMIN")
  field(LNK1, "XCOR:L3B:2485:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2485:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2485:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2485:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2485:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2485:EDES NPP MS")
  field(INPB, "XCOR:L3B:2485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2485:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2485:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2485:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2485:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2485:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2485:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2485:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2485:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2485:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2485:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2485:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2485:BMAX")
  field(DOL2, "YCOR:L3B:2485:BMAX")
  field(DOL3, "YCOR:L3B:2485:BMAX")
  field(DOL4, "YCOR:L3B:2485:BMIN")
  field(DOL5, "YCOR:L3B:2485:BMIN")
  field(DOL6, "YCOR:L3B:2485:BMIN")
  field(LNK1, "YCOR:L3B:2485:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2485:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2485:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2485:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2485:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2485:EDES NPP MS")
  field(INPB, "YCOR:L3B:2485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2585:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2585:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2585:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2585:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2585:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2585:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2585:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2585:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2585:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2585:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2585:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2585:BMAX")
  field(DOL2, "QUAD:L3B:2585:BMAX")
  field(DOL3, "QUAD:L3B:2585:BMAX")
  field(DOL4, "QUAD:L3B:2585:BMIN")
  field(DOL5, "QUAD:L3B:2585:BMIN")
  field(DOL6, "QUAD:L3B:2585:BMIN")
  field(LNK1, "QUAD:L3B:2585:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2585:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2585:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2585:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2585:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2585:EDES NPP MS")
  field(INPB, "QUAD:L3B:2585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2585:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2585:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2585:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2585:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2585:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2585:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2585:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2585:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2585:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2585:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2585:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2585:BMAX")
  field(DOL2, "XCOR:L3B:2585:BMAX")
  field(DOL3, "XCOR:L3B:2585:BMAX")
  field(DOL4, "XCOR:L3B:2585:BMIN")
  field(DOL5, "XCOR:L3B:2585:BMIN")
  field(DOL6, "XCOR:L3B:2585:BMIN")
  field(LNK1, "XCOR:L3B:2585:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2585:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2585:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2585:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2585:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2585:EDES NPP MS")
  field(INPB, "XCOR:L3B:2585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2585:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2585:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2585:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2585:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2585:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2585:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2585:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2585:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2585:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2585:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2585:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2585:BMAX")
  field(DOL2, "YCOR:L3B:2585:BMAX")
  field(DOL3, "YCOR:L3B:2585:BMAX")
  field(DOL4, "YCOR:L3B:2585:BMIN")
  field(DOL5, "YCOR:L3B:2585:BMIN")
  field(DOL6, "YCOR:L3B:2585:BMIN")
  field(LNK1, "YCOR:L3B:2585:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2585:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2585:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2585:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2585:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2585:EDES NPP MS")
  field(INPB, "YCOR:L3B:2585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2685:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2685:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2685:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2685:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2685:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2685:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2685:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2685:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2685:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2685:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2685:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2685:BMAX")
  field(DOL2, "QUAD:L3B:2685:BMAX")
  field(DOL3, "QUAD:L3B:2685:BMAX")
  field(DOL4, "QUAD:L3B:2685:BMIN")
  field(DOL5, "QUAD:L3B:2685:BMIN")
  field(DOL6, "QUAD:L3B:2685:BMIN")
  field(LNK1, "QUAD:L3B:2685:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2685:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2685:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2685:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2685:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2685:EDES NPP MS")
  field(INPB, "QUAD:L3B:2685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2685:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2685:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2685:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2685:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2685:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2685:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2685:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2685:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2685:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2685:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2685:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2685:BMAX")
  field(DOL2, "XCOR:L3B:2685:BMAX")
  field(DOL3, "XCOR:L3B:2685:BMAX")
  field(DOL4, "XCOR:L3B:2685:BMIN")
  field(DOL5, "XCOR:L3B:2685:BMIN")
  field(DOL6, "XCOR:L3B:2685:BMIN")
  field(LNK1, "XCOR:L3B:2685:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2685:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2685:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2685:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2685:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2685:EDES NPP MS")
  field(INPB, "XCOR:L3B:2685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2685:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2685:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2685:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2685:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2685:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2685:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2685:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2685:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2685:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2685:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2685:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2685:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2685:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2685:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2685:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2685:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2685:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2685:BMAX")
  field(DOL2, "YCOR:L3B:2685:BMAX")
  field(DOL3, "YCOR:L3B:2685:BMAX")
  field(DOL4, "YCOR:L3B:2685:BMIN")
  field(DOL5, "YCOR:L3B:2685:BMIN")
  field(DOL6, "YCOR:L3B:2685:BMIN")
  field(LNK1, "YCOR:L3B:2685:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2685:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2685:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2685:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2685:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2685:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2685:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2685:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2685:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2685:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2685:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2685:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2685:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2685:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2685:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2685:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2685:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2685:EDES NPP MS")
  field(INPB, "YCOR:L3B:2685:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2785:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2785:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2785:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2785:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2785:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2785:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2785:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2785:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2785:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2785:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2785:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2785:BMAX")
  field(DOL2, "QUAD:L3B:2785:BMAX")
  field(DOL3, "QUAD:L3B:2785:BMAX")
  field(DOL4, "QUAD:L3B:2785:BMIN")
  field(DOL5, "QUAD:L3B:2785:BMIN")
  field(DOL6, "QUAD:L3B:2785:BMIN")
  field(LNK1, "QUAD:L3B:2785:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2785:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2785:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2785:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2785:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2785:EDES NPP MS")
  field(INPB, "QUAD:L3B:2785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2785:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2785:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2785:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2785:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2785:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2785:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2785:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2785:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2785:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2785:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2785:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2785:BMAX")
  field(DOL2, "XCOR:L3B:2785:BMAX")
  field(DOL3, "XCOR:L3B:2785:BMAX")
  field(DOL4, "XCOR:L3B:2785:BMIN")
  field(DOL5, "XCOR:L3B:2785:BMIN")
  field(DOL6, "XCOR:L3B:2785:BMIN")
  field(LNK1, "XCOR:L3B:2785:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2785:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2785:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2785:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2785:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2785:EDES NPP MS")
  field(INPB, "XCOR:L3B:2785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2785:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2785:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2785:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2785:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2785:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2785:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2785:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2785:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2785:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2785:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2785:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2785:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2785:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2785:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2785:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2785:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2785:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2785:BMAX")
  field(DOL2, "YCOR:L3B:2785:BMAX")
  field(DOL3, "YCOR:L3B:2785:BMAX")
  field(DOL4, "YCOR:L3B:2785:BMIN")
  field(DOL5, "YCOR:L3B:2785:BMIN")
  field(DOL6, "YCOR:L3B:2785:BMIN")
  field(LNK1, "YCOR:L3B:2785:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2785:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2785:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2785:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2785:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2785:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2785:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2785:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2785:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2785:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2785:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2785:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2785:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2785:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2785:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2785:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2785:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2785:EDES NPP MS")
  field(INPB, "YCOR:L3B:2785:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2885:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2885:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2885:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2885:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2885:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2885:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2885:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2885:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2885:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2885:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2885:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2885:BMAX")
  field(DOL2, "QUAD:L3B:2885:BMAX")
  field(DOL3, "QUAD:L3B:2885:BMAX")
  field(DOL4, "QUAD:L3B:2885:BMIN")
  field(DOL5, "QUAD:L3B:2885:BMIN")
  field(DOL6, "QUAD:L3B:2885:BMIN")
  field(LNK1, "QUAD:L3B:2885:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2885:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2885:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2885:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2885:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2885:EDES NPP MS")
  field(INPB, "QUAD:L3B:2885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2885:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2885:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2885:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2885:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2885:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2885:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2885:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2885:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2885:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2885:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2885:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2885:BMAX")
  field(DOL2, "XCOR:L3B:2885:BMAX")
  field(DOL3, "XCOR:L3B:2885:BMAX")
  field(DOL4, "XCOR:L3B:2885:BMIN")
  field(DOL5, "XCOR:L3B:2885:BMIN")
  field(DOL6, "XCOR:L3B:2885:BMIN")
  field(LNK1, "XCOR:L3B:2885:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2885:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2885:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2885:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2885:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2885:EDES NPP MS")
  field(INPB, "XCOR:L3B:2885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2885:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2885:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2885:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2885:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2885:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2885:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2885:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2885:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2885:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2885:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2885:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2885:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2885:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2885:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2885:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2885:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2885:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2885:BMAX")
  field(DOL2, "YCOR:L3B:2885:BMAX")
  field(DOL3, "YCOR:L3B:2885:BMAX")
  field(DOL4, "YCOR:L3B:2885:BMIN")
  field(DOL5, "YCOR:L3B:2885:BMIN")
  field(DOL6, "YCOR:L3B:2885:BMIN")
  field(LNK1, "YCOR:L3B:2885:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2885:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2885:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2885:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2885:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2885:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2885:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2885:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2885:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2885:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2885:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2885:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2885:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2885:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2885:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2885:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2885:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2885:EDES NPP MS")
  field(INPB, "YCOR:L3B:2885:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:2985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:2985:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:2985:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:2985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:2985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:2985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:2985:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:2985:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:2985:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:2985:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:2985:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:2985:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:2985:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:2985:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:2985:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:2985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:2985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:2985:BMAX")
  field(DOL2, "QUAD:L3B:2985:BMAX")
  field(DOL3, "QUAD:L3B:2985:BMAX")
  field(DOL4, "QUAD:L3B:2985:BMIN")
  field(DOL5, "QUAD:L3B:2985:BMIN")
  field(DOL6, "QUAD:L3B:2985:BMIN")
  field(LNK1, "QUAD:L3B:2985:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:2985:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:2985:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:2985:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:2985:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:2985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:2985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:2985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:2985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:2985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:2985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:2985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:2985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:2985:EDES NPP MS")
  field(INPB, "QUAD:L3B:2985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:2985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:2985:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:2985:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:2985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:2985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:2985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:2985:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:2985:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:2985:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:2985:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:2985:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:2985:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:2985:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:2985:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:2985:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:2985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:2985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:2985:BMAX")
  field(DOL2, "XCOR:L3B:2985:BMAX")
  field(DOL3, "XCOR:L3B:2985:BMAX")
  field(DOL4, "XCOR:L3B:2985:BMIN")
  field(DOL5, "XCOR:L3B:2985:BMIN")
  field(DOL6, "XCOR:L3B:2985:BMIN")
  field(LNK1, "XCOR:L3B:2985:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:2985:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:2985:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:2985:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:2985:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:2985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:2985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:2985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:2985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:2985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:2985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:2985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:2985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:2985:EDES NPP MS")
  field(INPB, "XCOR:L3B:2985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:2985:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:2985:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:2985:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:2985:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:2985:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:2985:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:2985:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:2985:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:2985:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:2985:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:2985:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:2985:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:2985:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:2985:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:2985:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:2985:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:2985:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:2985:BMAX")
  field(DOL2, "YCOR:L3B:2985:BMAX")
  field(DOL3, "YCOR:L3B:2985:BMAX")
  field(DOL4, "YCOR:L3B:2985:BMIN")
  field(DOL5, "YCOR:L3B:2985:BMIN")
  field(DOL6, "YCOR:L3B:2985:BMIN")
  field(LNK1, "YCOR:L3B:2985:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:2985:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:2985:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:2985:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:2985:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:2985:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2985:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:2985:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:2985:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:2985:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:2985:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2985:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2985:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2985:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:2985:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:2985:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:2985:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:2985:EDES NPP MS")
  field(INPB, "YCOR:L3B:2985:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:3085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:3085:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:3085:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:3085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:3085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:3085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:3085:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:3085:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:3085:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:3085:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:3085:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:3085:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:3085:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:3085:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:3085:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:3085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:3085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:3085:BMAX")
  field(DOL2, "QUAD:L3B:3085:BMAX")
  field(DOL3, "QUAD:L3B:3085:BMAX")
  field(DOL4, "QUAD:L3B:3085:BMIN")
  field(DOL5, "QUAD:L3B:3085:BMIN")
  field(DOL6, "QUAD:L3B:3085:BMIN")
  field(LNK1, "QUAD:L3B:3085:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:3085:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:3085:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:3085:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:3085:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:3085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:3085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:3085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:3085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:3085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:3085:EDES NPP MS")
  field(INPB, "QUAD:L3B:3085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:3085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:3085:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:3085:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:3085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:3085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:3085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:3085:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:3085:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:3085:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:3085:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:3085:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:3085:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:3085:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:3085:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:3085:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:3085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:3085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:3085:BMAX")
  field(DOL2, "XCOR:L3B:3085:BMAX")
  field(DOL3, "XCOR:L3B:3085:BMAX")
  field(DOL4, "XCOR:L3B:3085:BMIN")
  field(DOL5, "XCOR:L3B:3085:BMIN")
  field(DOL6, "XCOR:L3B:3085:BMIN")
  field(LNK1, "XCOR:L3B:3085:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:3085:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:3085:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:3085:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:3085:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:3085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:3085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:3085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:3085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:3085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:3085:EDES NPP MS")
  field(INPB, "XCOR:L3B:3085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:3085:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:3085:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:3085:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:3085:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:3085:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:3085:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:3085:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:3085:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:3085:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:3085:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:3085:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:3085:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:3085:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:3085:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:3085:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:3085:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:3085:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:3085:BMAX")
  field(DOL2, "YCOR:L3B:3085:BMAX")
  field(DOL3, "YCOR:L3B:3085:BMAX")
  field(DOL4, "YCOR:L3B:3085:BMIN")
  field(DOL5, "YCOR:L3B:3085:BMIN")
  field(DOL6, "YCOR:L3B:3085:BMIN")
  field(LNK1, "YCOR:L3B:3085:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:3085:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:3085:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:3085:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:3085:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:3085:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3085:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3085:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:3085:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:3085:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:3085:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3085:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3085:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3085:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3085:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3085:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:3085:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:3085:EDES NPP MS")
  field(INPB, "YCOR:L3B:3085:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:3185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:3185:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:3185:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:3185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:3185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:3185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:3185:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:3185:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:3185:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:3185:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:3185:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:3185:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:3185:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:3185:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:3185:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:3185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:3185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:3185:BMAX")
  field(DOL2, "QUAD:L3B:3185:BMAX")
  field(DOL3, "QUAD:L3B:3185:BMAX")
  field(DOL4, "QUAD:L3B:3185:BMIN")
  field(DOL5, "QUAD:L3B:3185:BMIN")
  field(DOL6, "QUAD:L3B:3185:BMIN")
  field(LNK1, "QUAD:L3B:3185:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:3185:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:3185:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:3185:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:3185:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:3185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:3185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:3185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:3185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:3185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:3185:EDES NPP MS")
  field(INPB, "QUAD:L3B:3185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:3185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:3185:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:3185:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:3185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:3185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:3185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:3185:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:3185:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:3185:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:3185:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:3185:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:3185:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:3185:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:3185:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:3185:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:3185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:3185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:3185:BMAX")
  field(DOL2, "XCOR:L3B:3185:BMAX")
  field(DOL3, "XCOR:L3B:3185:BMAX")
  field(DOL4, "XCOR:L3B:3185:BMIN")
  field(DOL5, "XCOR:L3B:3185:BMIN")
  field(DOL6, "XCOR:L3B:3185:BMIN")
  field(LNK1, "XCOR:L3B:3185:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:3185:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:3185:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:3185:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:3185:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:3185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:3185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:3185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:3185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:3185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:3185:EDES NPP MS")
  field(INPB, "XCOR:L3B:3185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:3185:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:3185:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:3185:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:3185:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:3185:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:3185:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:3185:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:3185:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:3185:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:3185:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:3185:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:3185:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:3185:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:3185:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:3185:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:3185:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:3185:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:3185:BMAX")
  field(DOL2, "YCOR:L3B:3185:BMAX")
  field(DOL3, "YCOR:L3B:3185:BMAX")
  field(DOL4, "YCOR:L3B:3185:BMIN")
  field(DOL5, "YCOR:L3B:3185:BMIN")
  field(DOL6, "YCOR:L3B:3185:BMIN")
  field(LNK1, "YCOR:L3B:3185:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:3185:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:3185:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:3185:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:3185:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:3185:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3185:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3185:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:3185:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:3185:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:3185:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3185:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3185:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3185:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3185:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3185:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:3185:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:3185:EDES NPP MS")
  field(INPB, "YCOR:L3B:3185:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:3285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:3285:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:3285:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:3285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:3285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:3285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:3285:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:3285:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:3285:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:3285:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:3285:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:3285:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:3285:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:3285:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:3285:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:3285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:3285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:3285:BMAX")
  field(DOL2, "QUAD:L3B:3285:BMAX")
  field(DOL3, "QUAD:L3B:3285:BMAX")
  field(DOL4, "QUAD:L3B:3285:BMIN")
  field(DOL5, "QUAD:L3B:3285:BMIN")
  field(DOL6, "QUAD:L3B:3285:BMIN")
  field(LNK1, "QUAD:L3B:3285:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:3285:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:3285:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:3285:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:3285:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:3285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:3285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:3285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:3285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:3285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:3285:EDES NPP MS")
  field(INPB, "QUAD:L3B:3285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:3285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:3285:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:3285:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:3285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:3285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:3285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:3285:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:3285:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:3285:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:3285:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:3285:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:3285:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:3285:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:3285:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:3285:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:3285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:3285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:3285:BMAX")
  field(DOL2, "XCOR:L3B:3285:BMAX")
  field(DOL3, "XCOR:L3B:3285:BMAX")
  field(DOL4, "XCOR:L3B:3285:BMIN")
  field(DOL5, "XCOR:L3B:3285:BMIN")
  field(DOL6, "XCOR:L3B:3285:BMIN")
  field(LNK1, "XCOR:L3B:3285:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:3285:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:3285:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:3285:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:3285:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:3285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:3285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:3285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:3285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:3285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:3285:EDES NPP MS")
  field(INPB, "XCOR:L3B:3285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:3285:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:3285:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:3285:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:3285:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:3285:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:3285:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:3285:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:3285:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:3285:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:3285:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:3285:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:3285:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:3285:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:3285:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:3285:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:3285:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:3285:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:3285:BMAX")
  field(DOL2, "YCOR:L3B:3285:BMAX")
  field(DOL3, "YCOR:L3B:3285:BMAX")
  field(DOL4, "YCOR:L3B:3285:BMIN")
  field(DOL5, "YCOR:L3B:3285:BMIN")
  field(DOL6, "YCOR:L3B:3285:BMIN")
  field(LNK1, "YCOR:L3B:3285:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:3285:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:3285:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:3285:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:3285:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:3285:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3285:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3285:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:3285:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:3285:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:3285:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3285:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3285:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3285:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3285:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3285:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:3285:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:3285:EDES NPP MS")
  field(INPB, "YCOR:L3B:3285:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:3385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:3385:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:3385:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:3385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:3385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:3385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:3385:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:3385:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:3385:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:3385:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:3385:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:3385:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:3385:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:3385:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:3385:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:3385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:3385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:3385:BMAX")
  field(DOL2, "QUAD:L3B:3385:BMAX")
  field(DOL3, "QUAD:L3B:3385:BMAX")
  field(DOL4, "QUAD:L3B:3385:BMIN")
  field(DOL5, "QUAD:L3B:3385:BMIN")
  field(DOL6, "QUAD:L3B:3385:BMIN")
  field(LNK1, "QUAD:L3B:3385:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:3385:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:3385:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:3385:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:3385:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:3385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:3385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:3385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:3385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:3385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:3385:EDES NPP MS")
  field(INPB, "QUAD:L3B:3385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:3385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:3385:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:3385:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:3385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:3385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:3385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:3385:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:3385:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:3385:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:3385:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:3385:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:3385:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:3385:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:3385:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:3385:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:3385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:3385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:3385:BMAX")
  field(DOL2, "XCOR:L3B:3385:BMAX")
  field(DOL3, "XCOR:L3B:3385:BMAX")
  field(DOL4, "XCOR:L3B:3385:BMIN")
  field(DOL5, "XCOR:L3B:3385:BMIN")
  field(DOL6, "XCOR:L3B:3385:BMIN")
  field(LNK1, "XCOR:L3B:3385:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:3385:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:3385:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:3385:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:3385:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:3385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:3385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:3385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:3385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:3385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:3385:EDES NPP MS")
  field(INPB, "XCOR:L3B:3385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:3385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:3385:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:3385:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:3385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:3385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:3385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:3385:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:3385:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:3385:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:3385:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:3385:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:3385:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:3385:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:3385:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:3385:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:3385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:3385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:3385:BMAX")
  field(DOL2, "YCOR:L3B:3385:BMAX")
  field(DOL3, "YCOR:L3B:3385:BMAX")
  field(DOL4, "YCOR:L3B:3385:BMIN")
  field(DOL5, "YCOR:L3B:3385:BMIN")
  field(DOL6, "YCOR:L3B:3385:BMIN")
  field(LNK1, "YCOR:L3B:3385:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:3385:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:3385:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:3385:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:3385:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:3385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:3385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:3385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:3385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:3385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:3385:EDES NPP MS")
  field(INPB, "YCOR:L3B:3385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:3485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:3485:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:3485:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:3485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:3485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:3485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:3485:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:3485:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:3485:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:3485:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:3485:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:3485:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:3485:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:3485:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:3485:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:3485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:3485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:3485:BMAX")
  field(DOL2, "QUAD:L3B:3485:BMAX")
  field(DOL3, "QUAD:L3B:3485:BMAX")
  field(DOL4, "QUAD:L3B:3485:BMIN")
  field(DOL5, "QUAD:L3B:3485:BMIN")
  field(DOL6, "QUAD:L3B:3485:BMIN")
  field(LNK1, "QUAD:L3B:3485:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:3485:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:3485:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:3485:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:3485:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:3485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:3485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:3485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:3485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:3485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:3485:EDES NPP MS")
  field(INPB, "QUAD:L3B:3485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:3485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:3485:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:3485:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:3485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:3485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:3485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:3485:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:3485:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:3485:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:3485:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:3485:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:3485:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:3485:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:3485:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:3485:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:3485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:3485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:3485:BMAX")
  field(DOL2, "XCOR:L3B:3485:BMAX")
  field(DOL3, "XCOR:L3B:3485:BMAX")
  field(DOL4, "XCOR:L3B:3485:BMIN")
  field(DOL5, "XCOR:L3B:3485:BMIN")
  field(DOL6, "XCOR:L3B:3485:BMIN")
  field(LNK1, "XCOR:L3B:3485:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:3485:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:3485:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:3485:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:3485:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:3485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:3485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:3485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:3485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:3485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:3485:EDES NPP MS")
  field(INPB, "XCOR:L3B:3485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:3485:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:3485:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:3485:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:3485:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:3485:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:3485:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:3485:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:3485:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:3485:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:3485:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:3485:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:3485:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:3485:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:3485:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:3485:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:3485:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:3485:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:3485:BMAX")
  field(DOL2, "YCOR:L3B:3485:BMAX")
  field(DOL3, "YCOR:L3B:3485:BMAX")
  field(DOL4, "YCOR:L3B:3485:BMIN")
  field(DOL5, "YCOR:L3B:3485:BMIN")
  field(DOL6, "YCOR:L3B:3485:BMIN")
  field(LNK1, "YCOR:L3B:3485:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:3485:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:3485:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:3485:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:3485:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:3485:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3485:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3485:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:3485:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:3485:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:3485:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3485:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3485:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3485:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3485:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3485:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:3485:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:3485:EDES NPP MS")
  field(INPB, "YCOR:L3B:3485:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:L3B:3585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:L3B:3585:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:L3B:3585:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:L3B:3585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:L3B:3585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:L3B:3585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:L3B:3585:EDES.PROC PP")
    field(LNK2, "QUAD:L3B:3585:EACT.PROC PP")
    field(LNK3, "QUAD:L3B:3585:EERR.DISA PP")
    field(LNK4, "QUAD:L3B:3585:ECON.PROC PP")
    field(LNK5, "QUAD:L3B:3585:BMAGX.PROC PP")
    field(LNK6, "QUAD:L3B:3585:BMAGY.PROC PP")
    field(LNK7, "QUAD:L3B:3585:BLEM.PROC PP")
    field(LNK8, "QUAD:L3B:3585:BMOD.PROC PP")
    field(LNK9, "QUAD:L3B:3585:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:L3B:3585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:L3B:3585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:L3B:3585:BMAX")
  field(DOL2, "QUAD:L3B:3585:BMAX")
  field(DOL3, "QUAD:L3B:3585:BMAX")
  field(DOL4, "QUAD:L3B:3585:BMIN")
  field(DOL5, "QUAD:L3B:3585:BMIN")
  field(DOL6, "QUAD:L3B:3585:BMIN")
  field(LNK1, "QUAD:L3B:3585:BMAGX.HOPR")
  field(LNK2, "QUAD:L3B:3585:BMAGY.HOPR")
  field(LNK3, "QUAD:L3B:3585:BLEM.HOPR")
  field(LNK4, "QUAD:L3B:3585:BMAGX.LOPR PP")
  field(LNK5, "QUAD:L3B:3585:BMAGY.LOPR PP")
  field(LNK6, "QUAD:L3B:3585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:L3B:3585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:L3B:3585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:L3B:3585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:L3B:3585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:L3B:3585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:L3B:3585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:L3B:3585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:L3B:3585:EDES NPP MS")
  field(INPB, "QUAD:L3B:3585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:L3B:3585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:L3B:3585:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:L3B:3585:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:L3B:3585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:L3B:3585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:L3B:3585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:L3B:3585:EDES.PROC PP")
    field(LNK2, "XCOR:L3B:3585:EACT.PROC PP")
    field(LNK3, "XCOR:L3B:3585:EERR.DISA PP")
    field(LNK4, "XCOR:L3B:3585:ECON.PROC PP")
    field(LNK5, "XCOR:L3B:3585:BMAGX.PROC PP")
    field(LNK6, "XCOR:L3B:3585:BMAGY.PROC PP")
    field(LNK7, "XCOR:L3B:3585:BLEM.PROC PP")
    field(LNK8, "XCOR:L3B:3585:BMOD.PROC PP")
    field(LNK9, "XCOR:L3B:3585:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:L3B:3585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:L3B:3585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:L3B:3585:BMAX")
  field(DOL2, "XCOR:L3B:3585:BMAX")
  field(DOL3, "XCOR:L3B:3585:BMAX")
  field(DOL4, "XCOR:L3B:3585:BMIN")
  field(DOL5, "XCOR:L3B:3585:BMIN")
  field(DOL6, "XCOR:L3B:3585:BMIN")
  field(LNK1, "XCOR:L3B:3585:BMAGX.HOPR")
  field(LNK2, "XCOR:L3B:3585:BMAGY.HOPR")
  field(LNK3, "XCOR:L3B:3585:BLEM.HOPR")
  field(LNK4, "XCOR:L3B:3585:BMAGX.LOPR PP")
  field(LNK5, "XCOR:L3B:3585:BMAGY.LOPR PP")
  field(LNK6, "XCOR:L3B:3585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:L3B:3585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:L3B:3585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:L3B:3585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:L3B:3585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:L3B:3585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:L3B:3585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:L3B:3585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:L3B:3585:EDES NPP MS")
  field(INPB, "XCOR:L3B:3585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:L3B:3585:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:L3B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:L3B:1:CTRL.RVAL")
  field(LNK1, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL2, "MGNT:L3B:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL3, "MGNT:L3B:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL4, "MGNT:L3B:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL5, "MGNT:L3B:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL6, "MGNT:L3B:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL7, "MGNT:L3B:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL8, "MGNT:L3B:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:L3B:3585:FUNC CA PP")
  field(DOL9, "MGNT:L3B:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:L3B:3585:FUNC CA PP")
  field(DOLA, "MGNT:L3B:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:L3B:3585:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:L3B:3585:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:L3B:3585:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:L3B:3585:EDES.PROC PP")
    field(LNK2, "YCOR:L3B:3585:EACT.PROC PP")
    field(LNK3, "YCOR:L3B:3585:EERR.DISA PP")
    field(LNK4, "YCOR:L3B:3585:ECON.PROC PP")
    field(LNK5, "YCOR:L3B:3585:BMAGX.PROC PP")
    field(LNK6, "YCOR:L3B:3585:BMAGY.PROC PP")
    field(LNK7, "YCOR:L3B:3585:BLEM.PROC PP")
    field(LNK8, "YCOR:L3B:3585:BMOD.PROC PP")
    field(LNK9, "YCOR:L3B:3585:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:L3B:3585:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:L3B:3585:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:L3B:3585:BMAX")
  field(DOL2, "YCOR:L3B:3585:BMAX")
  field(DOL3, "YCOR:L3B:3585:BMAX")
  field(DOL4, "YCOR:L3B:3585:BMIN")
  field(DOL5, "YCOR:L3B:3585:BMIN")
  field(DOL6, "YCOR:L3B:3585:BMIN")
  field(LNK1, "YCOR:L3B:3585:BMAGX.HOPR")
  field(LNK2, "YCOR:L3B:3585:BMAGY.HOPR")
  field(LNK3, "YCOR:L3B:3585:BLEM.HOPR")
  field(LNK4, "YCOR:L3B:3585:BMAGX.LOPR PP")
  field(LNK5, "YCOR:L3B:3585:BMAGY.LOPR PP")
  field(LNK6, "YCOR:L3B:3585:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3585:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:L3B:3585:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:L3B:3585:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:L3B:3585:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:L3B:3585:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3585:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3585:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3585:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:L3B:3585:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:L3B:3585:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:L3B:3585:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:L3B:3585:EDES NPP MS")
  field(INPB, "YCOR:L3B:3585:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:EXT:351:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EXT:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EXT:1:CTRL.RVAL")
  field(LNK1, "QUAD:EXT:351:FUNC CA PP")
  field(DOL2, "MGNT:EXT:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:EXT:351:FUNC CA PP")
  field(DOL3, "MGNT:EXT:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:EXT:351:FUNC CA PP")
  field(DOL4, "MGNT:EXT:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:EXT:351:FUNC CA PP")
  field(DOL5, "MGNT:EXT:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:EXT:351:FUNC CA PP")
  field(DOL6, "MGNT:EXT:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:EXT:351:FUNC CA PP")
  field(DOL7, "MGNT:EXT:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:EXT:351:FUNC CA PP")
  field(DOL8, "MGNT:EXT:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:EXT:351:FUNC CA PP")
  field(DOL9, "MGNT:EXT:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:EXT:351:FUNC CA PP")
  field(DOLA, "MGNT:EXT:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:EXT:351:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:EXT:351:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:EXT:351:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:EXT:351:EDES.PROC PP")
    field(LNK2, "QUAD:EXT:351:EACT.PROC PP")
    field(LNK3, "QUAD:EXT:351:EERR.DISA PP")
    field(LNK4, "QUAD:EXT:351:ECON.PROC PP")
    field(LNK5, "QUAD:EXT:351:BMAGX.PROC PP")
    field(LNK6, "QUAD:EXT:351:BMAGY.PROC PP")
    field(LNK7, "QUAD:EXT:351:BLEM.PROC PP")
    field(LNK8, "QUAD:EXT:351:BMOD.PROC PP")
    field(LNK9, "QUAD:EXT:351:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:EXT:351:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:EXT:351:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:EXT:351:BMAX")
  field(DOL2, "QUAD:EXT:351:BMAX")
  field(DOL3, "QUAD:EXT:351:BMAX")
  field(DOL4, "QUAD:EXT:351:BMIN")
  field(DOL5, "QUAD:EXT:351:BMIN")
  field(DOL6, "QUAD:EXT:351:BMIN")
  field(LNK1, "QUAD:EXT:351:BMAGX.HOPR")
  field(LNK2, "QUAD:EXT:351:BMAGY.HOPR")
  field(LNK3, "QUAD:EXT:351:BLEM.HOPR")
  field(LNK4, "QUAD:EXT:351:BMAGX.LOPR PP")
  field(LNK5, "QUAD:EXT:351:BMAGY.LOPR PP")
  field(LNK6, "QUAD:EXT:351:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:EXT:351:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:EXT:351:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:EXT:351:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:EXT:351:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:EXT:351:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EXT:351:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EXT:351:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EXT:351:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EXT:351:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EXT:351:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:EXT:351:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:EXT:351:EDES NPP MS")
  field(INPB, "QUAD:EXT:351:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:EXT:748:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EXT:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EXT:1:CTRL.RVAL")
  field(LNK1, "QUAD:EXT:748:FUNC CA PP")
  field(DOL2, "MGNT:EXT:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:EXT:748:FUNC CA PP")
  field(DOL3, "MGNT:EXT:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:EXT:748:FUNC CA PP")
  field(DOL4, "MGNT:EXT:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:EXT:748:FUNC CA PP")
  field(DOL5, "MGNT:EXT:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:EXT:748:FUNC CA PP")
  field(DOL6, "MGNT:EXT:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:EXT:748:FUNC CA PP")
  field(DOL7, "MGNT:EXT:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:EXT:748:FUNC CA PP")
  field(DOL8, "MGNT:EXT:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:EXT:748:FUNC CA PP")
  field(DOL9, "MGNT:EXT:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:EXT:748:FUNC CA PP")
  field(DOLA, "MGNT:EXT:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:EXT:748:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:EXT:748:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:EXT:748:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:EXT:748:EDES.PROC PP")
    field(LNK2, "QUAD:EXT:748:EACT.PROC PP")
    field(LNK3, "QUAD:EXT:748:EERR.DISA PP")
    field(LNK4, "QUAD:EXT:748:ECON.PROC PP")
    field(LNK5, "QUAD:EXT:748:BMAGX.PROC PP")
    field(LNK6, "QUAD:EXT:748:BMAGY.PROC PP")
    field(LNK7, "QUAD:EXT:748:BLEM.PROC PP")
    field(LNK8, "QUAD:EXT:748:BMOD.PROC PP")
    field(LNK9, "QUAD:EXT:748:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:EXT:748:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:EXT:748:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:EXT:748:BMAX")
  field(DOL2, "QUAD:EXT:748:BMAX")
  field(DOL3, "QUAD:EXT:748:BMAX")
  field(DOL4, "QUAD:EXT:748:BMIN")
  field(DOL5, "QUAD:EXT:748:BMIN")
  field(DOL6, "QUAD:EXT:748:BMIN")
  field(LNK1, "QUAD:EXT:748:BMAGX.HOPR")
  field(LNK2, "QUAD:EXT:748:BMAGY.HOPR")
  field(LNK3, "QUAD:EXT:748:BLEM.HOPR")
  field(LNK4, "QUAD:EXT:748:BMAGX.LOPR PP")
  field(LNK5, "QUAD:EXT:748:BMAGY.LOPR PP")
  field(LNK6, "QUAD:EXT:748:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:EXT:748:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:EXT:748:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:EXT:748:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:EXT:748:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:EXT:748:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EXT:748:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EXT:748:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EXT:748:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:EXT:748:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:EXT:748:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:EXT:748:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:EXT:748:EDES NPP MS")
  field(INPB, "QUAD:EXT:748:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:EXT:368:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EXT:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EXT:1:CTRL.RVAL")
  field(LNK1, "XCOR:EXT:368:FUNC CA PP")
  field(DOL2, "MGNT:EXT:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:EXT:368:FUNC CA PP")
  field(DOL3, "MGNT:EXT:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:EXT:368:FUNC CA PP")
  field(DOL4, "MGNT:EXT:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:EXT:368:FUNC CA PP")
  field(DOL5, "MGNT:EXT:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:EXT:368:FUNC CA PP")
  field(DOL6, "MGNT:EXT:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:EXT:368:FUNC CA PP")
  field(DOL7, "MGNT:EXT:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:EXT:368:FUNC CA PP")
  field(DOL8, "MGNT:EXT:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:EXT:368:FUNC CA PP")
  field(DOL9, "MGNT:EXT:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:EXT:368:FUNC CA PP")
  field(DOLA, "MGNT:EXT:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:EXT:368:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:EXT:368:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:EXT:368:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:EXT:368:EDES.PROC PP")
    field(LNK2, "XCOR:EXT:368:EACT.PROC PP")
    field(LNK3, "XCOR:EXT:368:EERR.DISA PP")
    field(LNK4, "XCOR:EXT:368:ECON.PROC PP")
    field(LNK5, "XCOR:EXT:368:BMAGX.PROC PP")
    field(LNK6, "XCOR:EXT:368:BMAGY.PROC PP")
    field(LNK7, "XCOR:EXT:368:BLEM.PROC PP")
    field(LNK8, "XCOR:EXT:368:BMOD.PROC PP")
    field(LNK9, "XCOR:EXT:368:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:EXT:368:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:EXT:368:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:EXT:368:BMAX")
  field(DOL2, "XCOR:EXT:368:BMAX")
  field(DOL3, "XCOR:EXT:368:BMAX")
  field(DOL4, "XCOR:EXT:368:BMIN")
  field(DOL5, "XCOR:EXT:368:BMIN")
  field(DOL6, "XCOR:EXT:368:BMIN")
  field(LNK1, "XCOR:EXT:368:BMAGX.HOPR")
  field(LNK2, "XCOR:EXT:368:BMAGY.HOPR")
  field(LNK3, "XCOR:EXT:368:BLEM.HOPR")
  field(LNK4, "XCOR:EXT:368:BMAGX.LOPR PP")
  field(LNK5, "XCOR:EXT:368:BMAGY.LOPR PP")
  field(LNK6, "XCOR:EXT:368:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:EXT:368:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:EXT:368:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:EXT:368:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:EXT:368:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:EXT:368:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EXT:368:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:EXT:368:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:EXT:368:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:EXT:368:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:EXT:368:EDES NPP MS")
  field(INPB, "XCOR:EXT:368:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:EXT:762:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EXT:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EXT:1:CTRL.RVAL")
  field(LNK1, "YCOR:EXT:762:FUNC CA PP")
  field(DOL2, "MGNT:EXT:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:EXT:762:FUNC CA PP")
  field(DOL3, "MGNT:EXT:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:EXT:762:FUNC CA PP")
  field(DOL4, "MGNT:EXT:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:EXT:762:FUNC CA PP")
  field(DOL5, "MGNT:EXT:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:EXT:762:FUNC CA PP")
  field(DOL6, "MGNT:EXT:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:EXT:762:FUNC CA PP")
  field(DOL7, "MGNT:EXT:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:EXT:762:FUNC CA PP")
  field(DOL8, "MGNT:EXT:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:EXT:762:FUNC CA PP")
  field(DOL9, "MGNT:EXT:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:EXT:762:FUNC CA PP")
  field(DOLA, "MGNT:EXT:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:EXT:762:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:EXT:762:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:EXT:762:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:EXT:762:EDES.PROC PP")
    field(LNK2, "YCOR:EXT:762:EACT.PROC PP")
    field(LNK3, "YCOR:EXT:762:EERR.DISA PP")
    field(LNK4, "YCOR:EXT:762:ECON.PROC PP")
    field(LNK5, "YCOR:EXT:762:BMAGX.PROC PP")
    field(LNK6, "YCOR:EXT:762:BMAGY.PROC PP")
    field(LNK7, "YCOR:EXT:762:BLEM.PROC PP")
    field(LNK8, "YCOR:EXT:762:BMOD.PROC PP")
    field(LNK9, "YCOR:EXT:762:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:EXT:762:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:EXT:762:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:EXT:762:BMAX")
  field(DOL2, "YCOR:EXT:762:BMAX")
  field(DOL3, "YCOR:EXT:762:BMAX")
  field(DOL4, "YCOR:EXT:762:BMIN")
  field(DOL5, "YCOR:EXT:762:BMIN")
  field(DOL6, "YCOR:EXT:762:BMIN")
  field(LNK1, "YCOR:EXT:762:BMAGX.HOPR")
  field(LNK2, "YCOR:EXT:762:BMAGY.HOPR")
  field(LNK3, "YCOR:EXT:762:BLEM.HOPR")
  field(LNK4, "YCOR:EXT:762:BMAGX.LOPR PP")
  field(LNK5, "YCOR:EXT:762:BMAGY.LOPR PP")
  field(LNK6, "YCOR:EXT:762:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:EXT:762:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:EXT:762:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:EXT:762:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:EXT:762:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:EXT:762:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EXT:762:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:EXT:762:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:EXT:762:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:EXT:762:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:EXT:762:EDES NPP MS")
  field(INPB, "YCOR:EXT:762:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:106:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:106:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:106:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:106:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:106:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:106:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:106:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:106:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:106:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:106:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:106:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:106:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:106:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:106:EDES.PROC PP")
    field(LNK2, "BEND:DOG:106:EACT.PROC PP")
    field(LNK3, "BEND:DOG:106:EERR.DISA PP")
    field(LNK4, "BEND:DOG:106:ECON.PROC PP")
    field(LNK5, "BEND:DOG:106:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:106:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:106:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:106:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:106:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:106:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:106:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:106:BMAX")
  field(DOL2, "BEND:DOG:106:BMAX")
  field(DOL3, "BEND:DOG:106:BMAX")
  field(DOL4, "BEND:DOG:106:BMIN")
  field(DOL5, "BEND:DOG:106:BMIN")
  field(DOL6, "BEND:DOG:106:BMIN")
  field(LNK1, "BEND:DOG:106:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:106:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:106:BLEM.HOPR")
  field(LNK4, "BEND:DOG:106:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:106:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:106:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:106:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:106:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:106:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:106:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:106:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:106:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:106:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DOG:106:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:106:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DOG:106:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:106:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:106:EDES NPP MS")
  field(INPB, "BEND:DOG:106:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:240:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:240:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:240:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:240:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:240:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:240:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:240:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:240:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:240:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:240:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:240:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:240:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:240:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:240:EDES.PROC PP")
    field(LNK2, "BEND:DOG:240:EACT.PROC PP")
    field(LNK3, "BEND:DOG:240:EERR.DISA PP")
    field(LNK4, "BEND:DOG:240:ECON.PROC PP")
    field(LNK5, "BEND:DOG:240:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:240:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:240:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:240:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:240:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:240:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:240:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:240:BMAX")
  field(DOL2, "BEND:DOG:240:BMAX")
  field(DOL3, "BEND:DOG:240:BMAX")
  field(DOL4, "BEND:DOG:240:BMIN")
  field(DOL5, "BEND:DOG:240:BMIN")
  field(DOL6, "BEND:DOG:240:BMIN")
  field(LNK1, "BEND:DOG:240:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:240:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:240:BLEM.HOPR")
  field(LNK4, "BEND:DOG:240:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:240:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:240:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:240:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:240:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:240:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:240:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:240:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:240:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:240:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DOG:240:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:240:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DOG:240:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:240:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:240:EDES NPP MS")
  field(INPB, "BEND:DOG:240:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:242:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:242:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:242:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:242:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:242:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:242:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:242:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:242:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:242:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:242:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:242:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:242:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:242:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:242:EDES.PROC PP")
    field(LNK2, "BEND:DOG:242:EACT.PROC PP")
    field(LNK3, "BEND:DOG:242:EERR.DISA PP")
    field(LNK4, "BEND:DOG:242:ECON.PROC PP")
    field(LNK5, "BEND:DOG:242:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:242:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:242:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:242:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:242:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:242:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:242:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:242:BMAX")
  field(DOL2, "BEND:DOG:242:BMAX")
  field(DOL3, "BEND:DOG:242:BMAX")
  field(DOL4, "BEND:DOG:242:BMIN")
  field(DOL5, "BEND:DOG:242:BMIN")
  field(DOL6, "BEND:DOG:242:BMIN")
  field(LNK1, "BEND:DOG:242:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:242:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:242:BLEM.HOPR")
  field(LNK4, "BEND:DOG:242:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:242:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:242:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:242:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:242:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:242:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:242:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:242:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:242:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:242:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DOG:242:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:242:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DOG:242:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:242:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:242:EDES NPP MS")
  field(INPB, "BEND:DOG:242:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:105:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:105:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:105:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:105:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:105:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:105:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:105:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:105:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:105:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:105:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:105:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:105:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:105:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:105:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:105:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:105:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:105:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:105:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:105:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:105:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:105:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:105:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:105:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:105:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:105:BMAX")
  field(DOL2, "BTRM:DOG:105:BMAX")
  field(DOL3, "BTRM:DOG:105:BMAX")
  field(DOL4, "BTRM:DOG:105:BMIN")
  field(DOL5, "BTRM:DOG:105:BMIN")
  field(DOL6, "BTRM:DOG:105:BMIN")
  field(LNK1, "BTRM:DOG:105:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:105:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:105:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:105:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:105:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:105:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:105:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:105:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:105:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:105:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:105:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:105:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:105:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:105:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:105:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:105:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:105:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:105:EDES NPP MS")
  field(INPB, "BTRM:DOG:105:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:107:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:107:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:107:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:107:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:107:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:107:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:107:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:107:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:107:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:107:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:107:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:107:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:107:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:107:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:107:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:107:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:107:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:107:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:107:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:107:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:107:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:107:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:107:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:107:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:107:BMAX")
  field(DOL2, "BTRM:DOG:107:BMAX")
  field(DOL3, "BTRM:DOG:107:BMAX")
  field(DOL4, "BTRM:DOG:107:BMIN")
  field(DOL5, "BTRM:DOG:107:BMIN")
  field(DOL6, "BTRM:DOG:107:BMIN")
  field(LNK1, "BTRM:DOG:107:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:107:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:107:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:107:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:107:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:107:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:107:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:107:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:107:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:107:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:107:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:107:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:107:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:107:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:107:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:107:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:107:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:107:EDES NPP MS")
  field(INPB, "BTRM:DOG:107:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:108:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:108:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:108:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:108:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:108:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:108:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:108:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:108:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:108:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:108:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:108:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:108:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:108:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:108:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:108:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:108:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:108:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:108:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:108:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:108:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:108:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:108:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:108:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:108:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:108:BMAX")
  field(DOL2, "BTRM:DOG:108:BMAX")
  field(DOL3, "BTRM:DOG:108:BMAX")
  field(DOL4, "BTRM:DOG:108:BMIN")
  field(DOL5, "BTRM:DOG:108:BMIN")
  field(DOL6, "BTRM:DOG:108:BMIN")
  field(LNK1, "BTRM:DOG:108:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:108:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:108:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:108:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:108:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:108:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:108:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:108:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:108:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:108:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:108:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:108:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:108:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:108:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:108:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:108:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:108:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:108:EDES NPP MS")
  field(INPB, "BTRM:DOG:108:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:110:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:110:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:110:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:110:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:110:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:110:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:110:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:110:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:110:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:110:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:110:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:110:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:110:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:110:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:110:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:110:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:110:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:110:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:110:BMAX")
  field(DOL2, "BTRM:DOG:110:BMAX")
  field(DOL3, "BTRM:DOG:110:BMAX")
  field(DOL4, "BTRM:DOG:110:BMIN")
  field(DOL5, "BTRM:DOG:110:BMIN")
  field(DOL6, "BTRM:DOG:110:BMIN")
  field(LNK1, "BTRM:DOG:110:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:110:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:110:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:110:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:110:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:110:EDES NPP MS")
  field(INPB, "BTRM:DOG:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:241:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:241:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:241:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:241:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:241:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:241:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:241:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:241:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:241:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:241:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:241:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:241:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:241:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:241:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:241:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:241:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:241:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:241:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:241:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:241:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:241:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:241:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:241:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:241:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:241:BMAX")
  field(DOL2, "BTRM:DOG:241:BMAX")
  field(DOL3, "BTRM:DOG:241:BMAX")
  field(DOL4, "BTRM:DOG:241:BMIN")
  field(DOL5, "BTRM:DOG:241:BMIN")
  field(DOL6, "BTRM:DOG:241:BMIN")
  field(LNK1, "BTRM:DOG:241:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:241:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:241:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:241:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:241:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:241:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:241:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:241:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:241:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:241:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:241:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:241:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:241:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:241:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:241:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:241:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:241:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:241:EDES NPP MS")
  field(INPB, "BTRM:DOG:241:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:243:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:243:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:243:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:243:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:243:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:243:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:243:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:243:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:243:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:243:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:243:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:243:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:243:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:243:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:243:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:243:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:243:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:243:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:243:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:243:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:243:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:243:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:243:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:243:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:243:BMAX")
  field(DOL2, "BTRM:DOG:243:BMAX")
  field(DOL3, "BTRM:DOG:243:BMAX")
  field(DOL4, "BTRM:DOG:243:BMIN")
  field(DOL5, "BTRM:DOG:243:BMIN")
  field(DOL6, "BTRM:DOG:243:BMIN")
  field(LNK1, "BTRM:DOG:243:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:243:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:243:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:243:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:243:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:243:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:243:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:243:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:243:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:243:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:243:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:243:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:243:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:243:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:243:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:243:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:243:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:243:EDES NPP MS")
  field(INPB, "BTRM:DOG:243:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:DOG:244:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BTRM:DOG:244:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:DOG:244:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:DOG:244:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:DOG:244:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:DOG:244:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:DOG:244:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:DOG:244:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:DOG:244:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:DOG:244:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:DOG:244:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:DOG:244:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:DOG:244:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:DOG:244:EDES.PROC PP")
    field(LNK2, "BTRM:DOG:244:EACT.PROC PP")
    field(LNK3, "BTRM:DOG:244:EERR.DISA PP")
    field(LNK4, "BTRM:DOG:244:ECON.PROC PP")
    field(LNK5, "BTRM:DOG:244:BMAGX.PROC PP")
    field(LNK6, "BTRM:DOG:244:BMAGY.PROC PP")
    field(LNK7, "BTRM:DOG:244:BLEM.PROC PP")
    field(LNK8, "BTRM:DOG:244:BMOD.PROC PP")
    field(LNK9, "BTRM:DOG:244:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:DOG:244:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:DOG:244:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:DOG:244:BMAX")
  field(DOL2, "BTRM:DOG:244:BMAX")
  field(DOL3, "BTRM:DOG:244:BMAX")
  field(DOL4, "BTRM:DOG:244:BMIN")
  field(DOL5, "BTRM:DOG:244:BMIN")
  field(DOL6, "BTRM:DOG:244:BMIN")
  field(LNK1, "BTRM:DOG:244:BMAGX.HOPR")
  field(LNK2, "BTRM:DOG:244:BMAGY.HOPR")
  field(LNK3, "BTRM:DOG:244:BLEM.HOPR")
  field(LNK4, "BTRM:DOG:244:BMAGX.LOPR PP")
  field(LNK5, "BTRM:DOG:244:BMAGY.LOPR PP")
  field(LNK6, "BTRM:DOG:244:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:244:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:DOG:244:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:DOG:244:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:DOG:244:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:DOG:244:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:244:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:244:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:244:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:DOG:244:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:DOG:244:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:DOG:244:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:DOG:244:EDES NPP MS")
  field(INPB, "BTRM:DOG:244:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:120:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:120:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:120:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:120:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:120:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:120:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:120:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:120:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:120:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:120:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:120:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:120:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:120:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:120:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:120:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:120:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:120:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:120:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:120:BMAX")
  field(DOL2, "QUAD:DOG:120:BMAX")
  field(DOL3, "QUAD:DOG:120:BMAX")
  field(DOL4, "QUAD:DOG:120:BMIN")
  field(DOL5, "QUAD:DOG:120:BMIN")
  field(DOL6, "QUAD:DOG:120:BMIN")
  field(LNK1, "QUAD:DOG:120:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:120:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:120:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:120:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:120:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:120:EDES NPP MS")
  field(INPB, "QUAD:DOG:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:135:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:135:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:135:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:135:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:135:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:135:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:135:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:135:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:135:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:135:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:135:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:135:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:135:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:135:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:135:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:135:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:135:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:135:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:135:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:135:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:135:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:135:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:135:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:135:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:135:BMAX")
  field(DOL2, "QUAD:DOG:135:BMAX")
  field(DOL3, "QUAD:DOG:135:BMAX")
  field(DOL4, "QUAD:DOG:135:BMIN")
  field(DOL5, "QUAD:DOG:135:BMIN")
  field(DOL6, "QUAD:DOG:135:BMIN")
  field(LNK1, "QUAD:DOG:135:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:135:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:135:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:135:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:135:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:135:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:135:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:135:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:135:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:135:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:135:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:135:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:135:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:135:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:135:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:135:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:135:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:135:EDES NPP MS")
  field(INPB, "QUAD:DOG:135:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:150:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:150:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:150:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:150:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:150:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:150:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:150:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:150:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:150:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:150:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:150:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:150:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:150:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:150:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:150:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:150:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:150:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:150:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:150:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:150:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:150:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:150:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:150:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:150:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:150:BMAX")
  field(DOL2, "QUAD:DOG:150:BMAX")
  field(DOL3, "QUAD:DOG:150:BMAX")
  field(DOL4, "QUAD:DOG:150:BMIN")
  field(DOL5, "QUAD:DOG:150:BMIN")
  field(DOL6, "QUAD:DOG:150:BMIN")
  field(LNK1, "QUAD:DOG:150:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:150:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:150:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:150:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:150:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:150:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:150:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:150:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:150:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:150:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:150:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:150:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:150:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:150:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:150:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:150:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:150:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:150:EDES NPP MS")
  field(INPB, "QUAD:DOG:150:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:165:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:165:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:165:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:165:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:165:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:165:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:165:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:165:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:165:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:165:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:165:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:165:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:165:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:165:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:165:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:165:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:165:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:165:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:165:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:165:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:165:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:165:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:165:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:165:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:165:BMAX")
  field(DOL2, "QUAD:DOG:165:BMAX")
  field(DOL3, "QUAD:DOG:165:BMAX")
  field(DOL4, "QUAD:DOG:165:BMIN")
  field(DOL5, "QUAD:DOG:165:BMIN")
  field(DOL6, "QUAD:DOG:165:BMIN")
  field(LNK1, "QUAD:DOG:165:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:165:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:165:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:165:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:165:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:165:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:165:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:165:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:165:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:165:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:165:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:165:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:165:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:165:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:165:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:165:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:165:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:165:EDES NPP MS")
  field(INPB, "QUAD:DOG:165:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:250:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:250:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:250:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:250:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:250:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:250:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:250:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:250:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:250:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:250:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:250:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:250:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:250:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:250:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:250:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:250:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:250:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:250:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:250:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:250:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:250:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:250:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:250:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:250:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:250:BMAX")
  field(DOL2, "QUAD:DOG:250:BMAX")
  field(DOL3, "QUAD:DOG:250:BMAX")
  field(DOL4, "QUAD:DOG:250:BMIN")
  field(DOL5, "QUAD:DOG:250:BMIN")
  field(DOL6, "QUAD:DOG:250:BMIN")
  field(LNK1, "QUAD:DOG:250:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:250:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:250:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:250:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:250:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:250:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:250:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:250:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:250:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:250:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:250:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:250:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:250:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:250:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:250:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:250:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:250:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:250:EDES NPP MS")
  field(INPB, "QUAD:DOG:250:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:280:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:280:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:280:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:280:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:280:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:280:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:280:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:280:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:280:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:280:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:280:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:280:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:280:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:280:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:280:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:280:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:280:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:280:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:280:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:280:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:280:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:280:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:280:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:280:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:280:BMAX")
  field(DOL2, "QUAD:DOG:280:BMAX")
  field(DOL3, "QUAD:DOG:280:BMAX")
  field(DOL4, "QUAD:DOG:280:BMIN")
  field(DOL5, "QUAD:DOG:280:BMIN")
  field(DOL6, "QUAD:DOG:280:BMIN")
  field(LNK1, "QUAD:DOG:280:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:280:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:280:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:280:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:280:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:280:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:280:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:280:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:280:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:280:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:280:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:280:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:280:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:280:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:280:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:280:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:280:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:280:EDES NPP MS")
  field(INPB, "QUAD:DOG:280:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:335:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:335:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:335:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:335:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:335:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:335:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:335:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:335:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:335:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:335:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:335:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:335:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:335:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:335:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:335:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:335:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:335:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:335:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:335:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:335:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:335:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:335:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:335:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:335:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:335:BMAX")
  field(DOL2, "QUAD:DOG:335:BMAX")
  field(DOL3, "QUAD:DOG:335:BMAX")
  field(DOL4, "QUAD:DOG:335:BMIN")
  field(DOL5, "QUAD:DOG:335:BMIN")
  field(DOL6, "QUAD:DOG:335:BMIN")
  field(LNK1, "QUAD:DOG:335:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:335:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:335:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:335:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:335:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:335:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:335:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:335:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:335:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:335:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:335:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:335:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:335:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:335:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:335:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:335:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:335:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:335:EDES NPP MS")
  field(INPB, "QUAD:DOG:335:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:355:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:355:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:355:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:355:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:355:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:355:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:355:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:355:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:355:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:355:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:355:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:355:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:355:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:355:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:355:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:355:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:355:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:355:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:355:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:355:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:355:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:355:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:355:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:355:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:355:BMAX")
  field(DOL2, "QUAD:DOG:355:BMAX")
  field(DOL3, "QUAD:DOG:355:BMAX")
  field(DOL4, "QUAD:DOG:355:BMIN")
  field(DOL5, "QUAD:DOG:355:BMIN")
  field(DOL6, "QUAD:DOG:355:BMIN")
  field(LNK1, "QUAD:DOG:355:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:355:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:355:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:355:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:355:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:355:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:355:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:355:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:355:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:355:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:355:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:355:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:355:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:355:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:355:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:355:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:355:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:355:EDES NPP MS")
  field(INPB, "QUAD:DOG:355:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:405:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:405:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:405:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:405:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:405:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:405:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:405:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:405:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:405:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:405:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:405:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:405:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:405:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:405:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:405:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:405:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:405:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:405:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:405:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:405:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:405:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:405:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:405:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:405:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:405:BMAX")
  field(DOL2, "QUAD:DOG:405:BMAX")
  field(DOL3, "QUAD:DOG:405:BMAX")
  field(DOL4, "QUAD:DOG:405:BMIN")
  field(DOL5, "QUAD:DOG:405:BMIN")
  field(DOL6, "QUAD:DOG:405:BMIN")
  field(LNK1, "QUAD:DOG:405:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:405:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:405:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:405:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:405:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:405:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:405:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:405:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:405:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:405:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:405:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:405:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:405:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:405:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:405:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:405:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:405:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:405:EDES NPP MS")
  field(INPB, "QUAD:DOG:405:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:575:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:575:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:575:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:575:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:575:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:575:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:575:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:575:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:575:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:575:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:575:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:575:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:575:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:575:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:575:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:575:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:575:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:575:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:575:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:575:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:575:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:575:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:575:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:575:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:575:BMAX")
  field(DOL2, "QUAD:DOG:575:BMAX")
  field(DOL3, "QUAD:DOG:575:BMAX")
  field(DOL4, "QUAD:DOG:575:BMIN")
  field(DOL5, "QUAD:DOG:575:BMIN")
  field(DOL6, "QUAD:DOG:575:BMIN")
  field(LNK1, "QUAD:DOG:575:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:575:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:575:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:575:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:575:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:575:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:575:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:575:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:575:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:575:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:575:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:575:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:575:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:575:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:575:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:575:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:575:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:575:EDES NPP MS")
  field(INPB, "QUAD:DOG:575:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:116:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:116:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:116:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:116:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:116:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:116:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:116:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:116:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:116:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:116:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:116:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:116:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:116:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:116:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:116:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:116:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:116:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:116:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:116:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:116:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:116:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:116:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:116:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:116:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:116:BMAX")
  field(DOL2, "XCOR:DOG:116:BMAX")
  field(DOL3, "XCOR:DOG:116:BMAX")
  field(DOL4, "XCOR:DOG:116:BMIN")
  field(DOL5, "XCOR:DOG:116:BMIN")
  field(DOL6, "XCOR:DOG:116:BMIN")
  field(LNK1, "XCOR:DOG:116:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:116:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:116:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:116:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:116:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:116:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:116:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:116:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:116:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:116:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:116:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:116:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:116:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:116:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:116:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:116:EDES NPP MS")
  field(INPB, "XCOR:DOG:116:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:148:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:148:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:148:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:148:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:148:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:148:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:148:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:148:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:148:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:148:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:148:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:148:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:148:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:148:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:148:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:148:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:148:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:148:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:148:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:148:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:148:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:148:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:148:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:148:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:148:BMAX")
  field(DOL2, "XCOR:DOG:148:BMAX")
  field(DOL3, "XCOR:DOG:148:BMAX")
  field(DOL4, "XCOR:DOG:148:BMIN")
  field(DOL5, "XCOR:DOG:148:BMIN")
  field(DOL6, "XCOR:DOG:148:BMIN")
  field(LNK1, "XCOR:DOG:148:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:148:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:148:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:148:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:148:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:148:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:148:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:148:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:148:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:148:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:148:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:148:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:148:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:148:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:148:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:148:EDES NPP MS")
  field(INPB, "XCOR:DOG:148:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:178:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:178:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:178:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:178:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:178:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:178:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:178:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:178:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:178:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:178:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:178:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:178:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:178:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:178:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:178:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:178:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:178:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:178:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:178:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:178:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:178:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:178:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:178:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:178:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:178:BMAX")
  field(DOL2, "XCOR:DOG:178:BMAX")
  field(DOL3, "XCOR:DOG:178:BMAX")
  field(DOL4, "XCOR:DOG:178:BMIN")
  field(DOL5, "XCOR:DOG:178:BMIN")
  field(DOL6, "XCOR:DOG:178:BMIN")
  field(LNK1, "XCOR:DOG:178:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:178:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:178:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:178:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:178:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:178:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:178:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:178:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:178:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:178:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:178:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:178:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:178:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:178:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:178:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:178:EDES NPP MS")
  field(INPB, "XCOR:DOG:178:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:212:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:212:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:212:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:212:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:212:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:212:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:212:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:212:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:212:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:212:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:212:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:212:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:212:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:212:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:212:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:212:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:212:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:212:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:212:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:212:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:212:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:212:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:212:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:212:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:212:BMAX")
  field(DOL2, "XCOR:DOG:212:BMAX")
  field(DOL3, "XCOR:DOG:212:BMAX")
  field(DOL4, "XCOR:DOG:212:BMIN")
  field(DOL5, "XCOR:DOG:212:BMIN")
  field(DOL6, "XCOR:DOG:212:BMIN")
  field(LNK1, "XCOR:DOG:212:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:212:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:212:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:212:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:212:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:212:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:212:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:212:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:212:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:212:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:212:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:212:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:212:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:212:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:212:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:212:EDES NPP MS")
  field(INPB, "XCOR:DOG:212:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:252:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:252:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:252:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:252:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:252:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:252:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:252:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:252:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:252:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:252:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:252:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:252:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:252:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:252:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:252:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:252:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:252:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:252:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:252:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:252:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:252:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:252:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:252:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:252:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:252:BMAX")
  field(DOL2, "XCOR:DOG:252:BMAX")
  field(DOL3, "XCOR:DOG:252:BMAX")
  field(DOL4, "XCOR:DOG:252:BMIN")
  field(DOL5, "XCOR:DOG:252:BMIN")
  field(DOL6, "XCOR:DOG:252:BMIN")
  field(LNK1, "XCOR:DOG:252:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:252:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:252:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:252:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:252:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:252:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:252:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:252:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:252:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:252:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:252:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:252:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:252:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:252:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:252:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:252:EDES NPP MS")
  field(INPB, "XCOR:DOG:252:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:338:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:338:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:338:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:338:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:338:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:338:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:338:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:338:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:338:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:338:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:338:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:338:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:338:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:338:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:338:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:338:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:338:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:338:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:338:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:338:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:338:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:338:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:338:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:338:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:338:BMAX")
  field(DOL2, "XCOR:DOG:338:BMAX")
  field(DOL3, "XCOR:DOG:338:BMAX")
  field(DOL4, "XCOR:DOG:338:BMIN")
  field(DOL5, "XCOR:DOG:338:BMIN")
  field(DOL6, "XCOR:DOG:338:BMIN")
  field(LNK1, "XCOR:DOG:338:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:338:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:338:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:338:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:338:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:338:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:338:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:338:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:338:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:338:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:338:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:338:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:338:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:338:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:338:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:338:EDES NPP MS")
  field(INPB, "XCOR:DOG:338:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:408:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:408:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:408:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:408:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:408:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:408:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:408:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:408:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:408:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:408:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:408:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:408:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:408:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:408:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:408:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:408:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:408:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:408:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:408:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:408:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:408:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:408:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:408:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:408:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:408:BMAX")
  field(DOL2, "XCOR:DOG:408:BMAX")
  field(DOL3, "XCOR:DOG:408:BMAX")
  field(DOL4, "XCOR:DOG:408:BMIN")
  field(DOL5, "XCOR:DOG:408:BMIN")
  field(DOL6, "XCOR:DOG:408:BMIN")
  field(LNK1, "XCOR:DOG:408:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:408:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:408:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:408:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:408:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:408:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:408:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:408:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:408:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:408:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:408:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:408:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:408:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:408:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:408:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:408:EDES NPP MS")
  field(INPB, "XCOR:DOG:408:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:584:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:584:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:584:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:584:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:584:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:584:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:584:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:584:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:584:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:584:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:584:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:584:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:584:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:584:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:584:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:584:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:584:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:584:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:584:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:584:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:584:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:584:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:584:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:584:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:584:BMAX")
  field(DOL2, "XCOR:DOG:584:BMAX")
  field(DOL3, "XCOR:DOG:584:BMAX")
  field(DOL4, "XCOR:DOG:584:BMIN")
  field(DOL5, "XCOR:DOG:584:BMIN")
  field(DOL6, "XCOR:DOG:584:BMIN")
  field(LNK1, "XCOR:DOG:584:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:584:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:584:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:584:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:584:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:584:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:584:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:584:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:584:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:584:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:584:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:584:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:584:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:584:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:584:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:584:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:584:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:584:EDES NPP MS")
  field(INPB, "XCOR:DOG:584:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DOG:744:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "XCOR:DOG:744:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DOG:744:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DOG:744:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DOG:744:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DOG:744:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DOG:744:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DOG:744:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DOG:744:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DOG:744:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DOG:744:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DOG:744:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DOG:744:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DOG:744:EDES.PROC PP")
    field(LNK2, "XCOR:DOG:744:EACT.PROC PP")
    field(LNK3, "XCOR:DOG:744:EERR.DISA PP")
    field(LNK4, "XCOR:DOG:744:ECON.PROC PP")
    field(LNK5, "XCOR:DOG:744:BMAGX.PROC PP")
    field(LNK6, "XCOR:DOG:744:BMAGY.PROC PP")
    field(LNK7, "XCOR:DOG:744:BLEM.PROC PP")
    field(LNK8, "XCOR:DOG:744:BMOD.PROC PP")
    field(LNK9, "XCOR:DOG:744:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DOG:744:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DOG:744:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DOG:744:BMAX")
  field(DOL2, "XCOR:DOG:744:BMAX")
  field(DOL3, "XCOR:DOG:744:BMAX")
  field(DOL4, "XCOR:DOG:744:BMIN")
  field(DOL5, "XCOR:DOG:744:BMIN")
  field(DOL6, "XCOR:DOG:744:BMIN")
  field(LNK1, "XCOR:DOG:744:BMAGX.HOPR")
  field(LNK2, "XCOR:DOG:744:BMAGY.HOPR")
  field(LNK3, "XCOR:DOG:744:BLEM.HOPR")
  field(LNK4, "XCOR:DOG:744:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DOG:744:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DOG:744:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:744:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DOG:744:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DOG:744:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DOG:744:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DOG:744:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:744:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:744:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:744:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DOG:744:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DOG:744:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DOG:744:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DOG:744:EDES NPP MS")
  field(INPB, "XCOR:DOG:744:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:113:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:113:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:113:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:113:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:113:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:113:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:113:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:113:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:113:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:113:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:113:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:113:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:113:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:113:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:113:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:113:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:113:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:113:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:113:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:113:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:113:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:113:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:113:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:113:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:113:BMAX")
  field(DOL2, "YCOR:DOG:113:BMAX")
  field(DOL3, "YCOR:DOG:113:BMAX")
  field(DOL4, "YCOR:DOG:113:BMIN")
  field(DOL5, "YCOR:DOG:113:BMIN")
  field(DOL6, "YCOR:DOG:113:BMIN")
  field(LNK1, "YCOR:DOG:113:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:113:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:113:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:113:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:113:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:113:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:113:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:113:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:113:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:113:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:113:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:113:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:113:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:113:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:113:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:113:EDES NPP MS")
  field(INPB, "YCOR:DOG:113:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:137:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:137:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:137:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:137:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:137:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:137:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:137:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:137:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:137:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:137:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:137:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:137:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:137:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:137:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:137:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:137:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:137:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:137:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:137:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:137:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:137:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:137:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:137:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:137:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:137:BMAX")
  field(DOL2, "YCOR:DOG:137:BMAX")
  field(DOL3, "YCOR:DOG:137:BMAX")
  field(DOL4, "YCOR:DOG:137:BMIN")
  field(DOL5, "YCOR:DOG:137:BMIN")
  field(DOL6, "YCOR:DOG:137:BMIN")
  field(LNK1, "YCOR:DOG:137:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:137:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:137:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:137:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:137:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:137:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:137:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:137:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:137:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:137:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:137:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:137:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:137:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:137:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:137:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:137:EDES NPP MS")
  field(INPB, "YCOR:DOG:137:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:163:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:163:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:163:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:163:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:163:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:163:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:163:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:163:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:163:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:163:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:163:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:163:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:163:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:163:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:163:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:163:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:163:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:163:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:163:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:163:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:163:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:163:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:163:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:163:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:163:BMAX")
  field(DOL2, "YCOR:DOG:163:BMAX")
  field(DOL3, "YCOR:DOG:163:BMAX")
  field(DOL4, "YCOR:DOG:163:BMIN")
  field(DOL5, "YCOR:DOG:163:BMIN")
  field(DOL6, "YCOR:DOG:163:BMIN")
  field(LNK1, "YCOR:DOG:163:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:163:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:163:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:163:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:163:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:163:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:163:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:163:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:163:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:163:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:163:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:163:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:163:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:163:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:163:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:163:EDES NPP MS")
  field(INPB, "YCOR:DOG:163:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:193:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:193:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:193:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:193:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:193:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:193:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:193:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:193:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:193:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:193:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:193:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:193:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:193:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:193:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:193:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:193:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:193:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:193:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:193:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:193:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:193:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:193:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:193:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:193:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:193:BMAX")
  field(DOL2, "YCOR:DOG:193:BMAX")
  field(DOL3, "YCOR:DOG:193:BMAX")
  field(DOL4, "YCOR:DOG:193:BMIN")
  field(DOL5, "YCOR:DOG:193:BMIN")
  field(DOL6, "YCOR:DOG:193:BMIN")
  field(LNK1, "YCOR:DOG:193:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:193:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:193:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:193:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:193:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:193:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:193:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:193:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:193:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:193:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:193:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:193:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:193:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:193:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:193:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:193:EDES NPP MS")
  field(INPB, "YCOR:DOG:193:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:227:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:227:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:227:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:227:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:227:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:227:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:227:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:227:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:227:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:227:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:227:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:227:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:227:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:227:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:227:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:227:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:227:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:227:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:227:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:227:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:227:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:227:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:227:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:227:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:227:BMAX")
  field(DOL2, "YCOR:DOG:227:BMAX")
  field(DOL3, "YCOR:DOG:227:BMAX")
  field(DOL4, "YCOR:DOG:227:BMIN")
  field(DOL5, "YCOR:DOG:227:BMIN")
  field(DOL6, "YCOR:DOG:227:BMIN")
  field(LNK1, "YCOR:DOG:227:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:227:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:227:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:227:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:227:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:227:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:227:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:227:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:227:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:227:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:227:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:227:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:227:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:227:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:227:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:227:EDES NPP MS")
  field(INPB, "YCOR:DOG:227:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:281:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:281:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:281:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:281:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:281:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:281:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:281:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:281:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:281:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:281:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:281:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:281:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:281:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:281:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:281:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:281:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:281:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:281:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:281:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:281:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:281:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:281:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:281:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:281:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:281:BMAX")
  field(DOL2, "YCOR:DOG:281:BMAX")
  field(DOL3, "YCOR:DOG:281:BMAX")
  field(DOL4, "YCOR:DOG:281:BMIN")
  field(DOL5, "YCOR:DOG:281:BMIN")
  field(DOL6, "YCOR:DOG:281:BMIN")
  field(LNK1, "YCOR:DOG:281:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:281:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:281:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:281:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:281:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:281:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:281:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:281:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:281:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:281:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:281:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:281:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:281:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:281:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:281:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:281:EDES NPP MS")
  field(INPB, "YCOR:DOG:281:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:357:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:357:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:357:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:357:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:357:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:357:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:357:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:357:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:357:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:357:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:357:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:357:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:357:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:357:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:357:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:357:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:357:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:357:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:357:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:357:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:357:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:357:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:357:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:357:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:357:BMAX")
  field(DOL2, "YCOR:DOG:357:BMAX")
  field(DOL3, "YCOR:DOG:357:BMAX")
  field(DOL4, "YCOR:DOG:357:BMIN")
  field(DOL5, "YCOR:DOG:357:BMIN")
  field(DOL6, "YCOR:DOG:357:BMIN")
  field(LNK1, "YCOR:DOG:357:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:357:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:357:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:357:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:357:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:357:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:357:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:357:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:357:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:357:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:357:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:357:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:357:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:357:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:357:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:357:EDES NPP MS")
  field(INPB, "YCOR:DOG:357:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:577:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:577:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:577:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:577:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:577:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:577:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:577:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:577:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:577:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:577:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:577:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:577:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:577:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:577:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:577:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:577:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:577:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:577:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:577:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:577:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:577:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:577:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:577:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:577:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:577:BMAX")
  field(DOL2, "YCOR:DOG:577:BMAX")
  field(DOL3, "YCOR:DOG:577:BMAX")
  field(DOL4, "YCOR:DOG:577:BMIN")
  field(DOL5, "YCOR:DOG:577:BMIN")
  field(DOL6, "YCOR:DOG:577:BMIN")
  field(LNK1, "YCOR:DOG:577:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:577:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:577:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:577:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:577:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:577:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:577:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:577:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:577:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:577:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:577:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:577:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:577:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:577:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:577:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:577:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:577:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:577:EDES NPP MS")
  field(INPB, "YCOR:DOG:577:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DOG:911:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "YCOR:DOG:911:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DOG:911:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DOG:911:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DOG:911:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DOG:911:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DOG:911:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DOG:911:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DOG:911:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DOG:911:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DOG:911:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DOG:911:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DOG:911:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DOG:911:EDES.PROC PP")
    field(LNK2, "YCOR:DOG:911:EACT.PROC PP")
    field(LNK3, "YCOR:DOG:911:EERR.DISA PP")
    field(LNK4, "YCOR:DOG:911:ECON.PROC PP")
    field(LNK5, "YCOR:DOG:911:BMAGX.PROC PP")
    field(LNK6, "YCOR:DOG:911:BMAGY.PROC PP")
    field(LNK7, "YCOR:DOG:911:BLEM.PROC PP")
    field(LNK8, "YCOR:DOG:911:BMOD.PROC PP")
    field(LNK9, "YCOR:DOG:911:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DOG:911:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DOG:911:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DOG:911:BMAX")
  field(DOL2, "YCOR:DOG:911:BMAX")
  field(DOL3, "YCOR:DOG:911:BMAX")
  field(DOL4, "YCOR:DOG:911:BMIN")
  field(DOL5, "YCOR:DOG:911:BMIN")
  field(DOL6, "YCOR:DOG:911:BMIN")
  field(LNK1, "YCOR:DOG:911:BMAGX.HOPR")
  field(LNK2, "YCOR:DOG:911:BMAGY.HOPR")
  field(LNK3, "YCOR:DOG:911:BLEM.HOPR")
  field(LNK4, "YCOR:DOG:911:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DOG:911:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DOG:911:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:911:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DOG:911:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DOG:911:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DOG:911:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DOG:911:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:911:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:911:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:911:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DOG:911:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DOG:911:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DOG:911:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DOG:911:EDES NPP MS")
  field(INPB, "YCOR:DOG:911:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:575:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:575:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:575:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:575:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:575:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:575:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:575:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:575:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:575:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:575:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:575:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:575:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:575:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:575:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:575:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:575:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:575:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:575:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:575:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:575:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:575:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:575:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:575:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:575:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:575:BMAX")
  field(DOL2, "QUAD:DOG:575:BMAX")
  field(DOL3, "QUAD:DOG:575:BMAX")
  field(DOL4, "QUAD:DOG:575:BMIN")
  field(DOL5, "QUAD:DOG:575:BMIN")
  field(DOL6, "QUAD:DOG:575:BMIN")
  field(LNK1, "QUAD:DOG:575:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:575:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:575:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:575:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:575:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:575:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:575:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:575:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:575:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:575:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:575:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:575:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:575:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:575:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:575:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DOG:575:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:575:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:575:EDES NPP MS")
  field(INPB, "QUAD:DOG:575:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN25:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN25:400:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN25:400:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN25:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN25:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN25:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN25:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN25:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN25:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN25:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN25:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN25:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN25:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN25:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN25:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN25:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN25:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN25:400:BMAX")
  field(DOL2, "QUAD:BPN25:400:BMAX")
  field(DOL3, "QUAD:BPN25:400:BMAX")
  field(DOL4, "QUAD:BPN25:400:BMIN")
  field(DOL5, "QUAD:BPN25:400:BMIN")
  field(DOL6, "QUAD:BPN25:400:BMIN")
  field(LNK1, "QUAD:BPN25:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN25:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN25:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN25:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN25:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN25:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN25:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN25:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN25:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN25:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN25:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN25:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN25:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN25:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN25:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN25:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN25:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN25:400:EDES NPP MS")
  field(INPB, "QUAD:BPN25:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN26:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN26:400:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN26:400:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN26:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN26:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN26:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN26:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN26:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN26:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN26:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN26:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN26:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN26:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN26:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN26:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN26:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN26:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN26:400:BMAX")
  field(DOL2, "QUAD:BPN26:400:BMAX")
  field(DOL3, "QUAD:BPN26:400:BMAX")
  field(DOL4, "QUAD:BPN26:400:BMIN")
  field(DOL5, "QUAD:BPN26:400:BMIN")
  field(DOL6, "QUAD:BPN26:400:BMIN")
  field(LNK1, "QUAD:BPN26:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN26:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN26:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN26:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN26:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN26:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN26:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN26:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN26:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN26:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN26:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN26:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN26:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN26:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN26:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN26:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN26:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN26:400:EDES NPP MS")
  field(INPB, "QUAD:BPN26:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN27:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN27:400:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN27:400:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN27:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN27:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN27:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN27:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN27:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN27:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN27:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN27:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN27:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN27:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN27:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN27:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN27:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN27:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN27:400:BMAX")
  field(DOL2, "QUAD:BPN27:400:BMAX")
  field(DOL3, "QUAD:BPN27:400:BMAX")
  field(DOL4, "QUAD:BPN27:400:BMIN")
  field(DOL5, "QUAD:BPN27:400:BMIN")
  field(DOL6, "QUAD:BPN27:400:BMIN")
  field(LNK1, "QUAD:BPN27:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN27:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN27:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN27:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN27:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN27:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN27:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN27:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN27:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN27:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN27:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN27:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN27:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN27:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN27:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN27:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN27:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN27:400:EDES NPP MS")
  field(INPB, "QUAD:BPN27:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN28:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN28:200:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN28:200:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN28:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN28:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN28:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN28:200:EDES.PROC PP")
    field(LNK2, "QUAD:BPN28:200:EACT.PROC PP")
    field(LNK3, "QUAD:BPN28:200:EERR.DISA PP")
    field(LNK4, "QUAD:BPN28:200:ECON.PROC PP")
    field(LNK5, "QUAD:BPN28:200:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN28:200:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN28:200:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN28:200:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN28:200:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN28:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN28:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN28:200:BMAX")
  field(DOL2, "QUAD:BPN28:200:BMAX")
  field(DOL3, "QUAD:BPN28:200:BMAX")
  field(DOL4, "QUAD:BPN28:200:BMIN")
  field(DOL5, "QUAD:BPN28:200:BMIN")
  field(DOL6, "QUAD:BPN28:200:BMIN")
  field(LNK1, "QUAD:BPN28:200:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN28:200:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN28:200:BLEM.HOPR")
  field(LNK4, "QUAD:BPN28:200:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN28:200:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN28:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN28:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN28:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN28:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN28:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN28:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN28:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN28:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN28:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN28:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN28:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN28:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN28:200:EDES NPP MS")
  field(INPB, "QUAD:BPN28:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN28:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN28:400:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN28:400:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN28:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN28:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN28:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN28:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN28:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN28:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN28:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN28:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN28:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN28:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN28:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN28:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN28:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN28:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN28:400:BMAX")
  field(DOL2, "QUAD:BPN28:400:BMAX")
  field(DOL3, "QUAD:BPN28:400:BMAX")
  field(DOL4, "QUAD:BPN28:400:BMIN")
  field(DOL5, "QUAD:BPN28:400:BMIN")
  field(DOL6, "QUAD:BPN28:400:BMIN")
  field(LNK1, "QUAD:BPN28:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN28:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN28:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN28:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN28:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN28:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN28:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN28:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN28:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN28:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN28:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN28:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN28:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN28:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN28:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:BPN28:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN28:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN28:400:EDES NPP MS")
  field(INPB, "QUAD:BPN28:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN13:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN13:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN13:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN13:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN13:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN13:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN13:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN13:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN13:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN13:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN13:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN13:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN13:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN13:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN13:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN13:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN13:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN13:406:BMAX")
  field(DOL2, "XCOR:BPN13:406:BMAX")
  field(DOL3, "XCOR:BPN13:406:BMAX")
  field(DOL4, "XCOR:BPN13:406:BMIN")
  field(DOL5, "XCOR:BPN13:406:BMIN")
  field(DOL6, "XCOR:BPN13:406:BMIN")
  field(LNK1, "XCOR:BPN13:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN13:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN13:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN13:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN13:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN13:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN13:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN13:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN13:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN13:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN13:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN13:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN13:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN13:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN13:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN13:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN13:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN13:406:EDES NPP MS")
  field(INPB, "XCOR:BPN13:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN14:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN14:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN14:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN14:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN14:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN14:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN14:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN14:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN14:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN14:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN14:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN14:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN14:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN14:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN14:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN14:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN14:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN14:406:BMAX")
  field(DOL2, "XCOR:BPN14:406:BMAX")
  field(DOL3, "XCOR:BPN14:406:BMAX")
  field(DOL4, "XCOR:BPN14:406:BMIN")
  field(DOL5, "XCOR:BPN14:406:BMIN")
  field(DOL6, "XCOR:BPN14:406:BMIN")
  field(LNK1, "XCOR:BPN14:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN14:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN14:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN14:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN14:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN14:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN14:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN14:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN14:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN14:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN14:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN14:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN14:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN14:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN14:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN14:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN14:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN14:406:EDES NPP MS")
  field(INPB, "XCOR:BPN14:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN15:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN15:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN15:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN15:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN15:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN15:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN15:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN15:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN15:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN15:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN15:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN15:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN15:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN15:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN15:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN15:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN15:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN15:406:BMAX")
  field(DOL2, "XCOR:BPN15:406:BMAX")
  field(DOL3, "XCOR:BPN15:406:BMAX")
  field(DOL4, "XCOR:BPN15:406:BMIN")
  field(DOL5, "XCOR:BPN15:406:BMIN")
  field(DOL6, "XCOR:BPN15:406:BMIN")
  field(LNK1, "XCOR:BPN15:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN15:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN15:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN15:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN15:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN15:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN15:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN15:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN15:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN15:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN15:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN15:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN15:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN15:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN15:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN15:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN15:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN15:406:EDES NPP MS")
  field(INPB, "XCOR:BPN15:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN16:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN16:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN16:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN16:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN16:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN16:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN16:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN16:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN16:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN16:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN16:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN16:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN16:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN16:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN16:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN16:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN16:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN16:406:BMAX")
  field(DOL2, "XCOR:BPN16:406:BMAX")
  field(DOL3, "XCOR:BPN16:406:BMAX")
  field(DOL4, "XCOR:BPN16:406:BMIN")
  field(DOL5, "XCOR:BPN16:406:BMIN")
  field(DOL6, "XCOR:BPN16:406:BMIN")
  field(LNK1, "XCOR:BPN16:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN16:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN16:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN16:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN16:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN16:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN16:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN16:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN16:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN16:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN16:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN16:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN16:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN16:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN16:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN16:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN16:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN16:406:EDES NPP MS")
  field(INPB, "XCOR:BPN16:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN17:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN17:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN17:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN17:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN17:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN17:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN17:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN17:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN17:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN17:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN17:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN17:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN17:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN17:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN17:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN17:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN17:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN17:406:BMAX")
  field(DOL2, "XCOR:BPN17:406:BMAX")
  field(DOL3, "XCOR:BPN17:406:BMAX")
  field(DOL4, "XCOR:BPN17:406:BMIN")
  field(DOL5, "XCOR:BPN17:406:BMIN")
  field(DOL6, "XCOR:BPN17:406:BMIN")
  field(LNK1, "XCOR:BPN17:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN17:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN17:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN17:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN17:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN17:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN17:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN17:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN17:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN17:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN17:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN17:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN17:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN17:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN17:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN17:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN17:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN17:406:EDES NPP MS")
  field(INPB, "XCOR:BPN17:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN18:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN18:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN18:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN18:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN18:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN18:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN18:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN18:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN18:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN18:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN18:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN18:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN18:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN18:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN18:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN18:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN18:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN18:406:BMAX")
  field(DOL2, "XCOR:BPN18:406:BMAX")
  field(DOL3, "XCOR:BPN18:406:BMAX")
  field(DOL4, "XCOR:BPN18:406:BMIN")
  field(DOL5, "XCOR:BPN18:406:BMIN")
  field(DOL6, "XCOR:BPN18:406:BMIN")
  field(LNK1, "XCOR:BPN18:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN18:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN18:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN18:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN18:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN18:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN18:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN18:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN18:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN18:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN18:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN18:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN18:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN18:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN18:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN18:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN18:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN18:406:EDES NPP MS")
  field(INPB, "XCOR:BPN18:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN19:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN19:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN19:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN19:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN19:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN19:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN19:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN19:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN19:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN19:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN19:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN19:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN19:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN19:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN19:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN19:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN19:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN19:406:BMAX")
  field(DOL2, "XCOR:BPN19:406:BMAX")
  field(DOL3, "XCOR:BPN19:406:BMAX")
  field(DOL4, "XCOR:BPN19:406:BMIN")
  field(DOL5, "XCOR:BPN19:406:BMIN")
  field(DOL6, "XCOR:BPN19:406:BMIN")
  field(LNK1, "XCOR:BPN19:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN19:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN19:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN19:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN19:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN19:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN19:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN19:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN19:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN19:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN19:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN19:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN19:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN19:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN19:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN19:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN19:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN19:406:EDES NPP MS")
  field(INPB, "XCOR:BPN19:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN20:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN20:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN20:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN20:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN20:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN20:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN20:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN20:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN20:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN20:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN20:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN20:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN20:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN20:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN20:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN20:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN20:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN20:406:BMAX")
  field(DOL2, "XCOR:BPN20:406:BMAX")
  field(DOL3, "XCOR:BPN20:406:BMAX")
  field(DOL4, "XCOR:BPN20:406:BMIN")
  field(DOL5, "XCOR:BPN20:406:BMIN")
  field(DOL6, "XCOR:BPN20:406:BMIN")
  field(LNK1, "XCOR:BPN20:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN20:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN20:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN20:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN20:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN20:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN20:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN20:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN20:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN20:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN20:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN20:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN20:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN20:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN20:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN20:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN20:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN20:406:EDES NPP MS")
  field(INPB, "XCOR:BPN20:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN21:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN21:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN21:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN21:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN21:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN21:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN21:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN21:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN21:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN21:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN21:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN21:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN21:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN21:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN21:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN21:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN21:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN21:406:BMAX")
  field(DOL2, "XCOR:BPN21:406:BMAX")
  field(DOL3, "XCOR:BPN21:406:BMAX")
  field(DOL4, "XCOR:BPN21:406:BMIN")
  field(DOL5, "XCOR:BPN21:406:BMIN")
  field(DOL6, "XCOR:BPN21:406:BMIN")
  field(LNK1, "XCOR:BPN21:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN21:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN21:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN21:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN21:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN21:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN21:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN21:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN21:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN21:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN21:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN21:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN21:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN21:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN21:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN21:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN21:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN21:406:EDES NPP MS")
  field(INPB, "XCOR:BPN21:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN22:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN22:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN22:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN22:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN22:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN22:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN22:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN22:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN22:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN22:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN22:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN22:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN22:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN22:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN22:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN22:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN22:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN22:406:BMAX")
  field(DOL2, "XCOR:BPN22:406:BMAX")
  field(DOL3, "XCOR:BPN22:406:BMAX")
  field(DOL4, "XCOR:BPN22:406:BMIN")
  field(DOL5, "XCOR:BPN22:406:BMIN")
  field(DOL6, "XCOR:BPN22:406:BMIN")
  field(LNK1, "XCOR:BPN22:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN22:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN22:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN22:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN22:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN22:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN22:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN22:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN22:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN22:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN22:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN22:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN22:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN22:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN22:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN22:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN22:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN22:406:EDES NPP MS")
  field(INPB, "XCOR:BPN22:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN23:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN23:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN23:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN23:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN23:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN23:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN23:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN23:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN23:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN23:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN23:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN23:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN23:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN23:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN23:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN23:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN23:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN23:406:BMAX")
  field(DOL2, "XCOR:BPN23:406:BMAX")
  field(DOL3, "XCOR:BPN23:406:BMAX")
  field(DOL4, "XCOR:BPN23:406:BMIN")
  field(DOL5, "XCOR:BPN23:406:BMIN")
  field(DOL6, "XCOR:BPN23:406:BMIN")
  field(LNK1, "XCOR:BPN23:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN23:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN23:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN23:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN23:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN23:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN23:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN23:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN23:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN23:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN23:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN23:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN23:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN23:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN23:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN23:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN23:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN23:406:EDES NPP MS")
  field(INPB, "XCOR:BPN23:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN24:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN24:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN24:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN24:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN24:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN24:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN24:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN24:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN24:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN24:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN24:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN24:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN24:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN24:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN24:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN24:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN24:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN24:406:BMAX")
  field(DOL2, "XCOR:BPN24:406:BMAX")
  field(DOL3, "XCOR:BPN24:406:BMAX")
  field(DOL4, "XCOR:BPN24:406:BMIN")
  field(DOL5, "XCOR:BPN24:406:BMIN")
  field(DOL6, "XCOR:BPN24:406:BMIN")
  field(LNK1, "XCOR:BPN24:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN24:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN24:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN24:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN24:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN24:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN24:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN24:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN24:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN24:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN24:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN24:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN24:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN24:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN24:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN24:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN24:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN24:406:EDES NPP MS")
  field(INPB, "XCOR:BPN24:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN25:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN25:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN25:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN25:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN25:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN25:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN25:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN25:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN25:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN25:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN25:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN25:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN25:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN25:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN25:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN25:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN25:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN25:406:BMAX")
  field(DOL2, "XCOR:BPN25:406:BMAX")
  field(DOL3, "XCOR:BPN25:406:BMAX")
  field(DOL4, "XCOR:BPN25:406:BMIN")
  field(DOL5, "XCOR:BPN25:406:BMIN")
  field(DOL6, "XCOR:BPN25:406:BMIN")
  field(LNK1, "XCOR:BPN25:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN25:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN25:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN25:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN25:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN25:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN25:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN25:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN25:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN25:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN25:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN25:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN25:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN25:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN25:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN25:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN25:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN25:406:EDES NPP MS")
  field(INPB, "XCOR:BPN25:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN26:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN26:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN26:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN26:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN26:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN26:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN26:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN26:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN26:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN26:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN26:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN26:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN26:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN26:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN26:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN26:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN26:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN26:406:BMAX")
  field(DOL2, "XCOR:BPN26:406:BMAX")
  field(DOL3, "XCOR:BPN26:406:BMAX")
  field(DOL4, "XCOR:BPN26:406:BMIN")
  field(DOL5, "XCOR:BPN26:406:BMIN")
  field(DOL6, "XCOR:BPN26:406:BMIN")
  field(LNK1, "XCOR:BPN26:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN26:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN26:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN26:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN26:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN26:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN26:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN26:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN26:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN26:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN26:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN26:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN26:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN26:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN26:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN26:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN26:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN26:406:EDES NPP MS")
  field(INPB, "XCOR:BPN26:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN27:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN27:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN27:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN27:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN27:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN27:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN27:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN27:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN27:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN27:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN27:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN27:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN27:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN27:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN27:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN27:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN27:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN27:406:BMAX")
  field(DOL2, "XCOR:BPN27:406:BMAX")
  field(DOL3, "XCOR:BPN27:406:BMAX")
  field(DOL4, "XCOR:BPN27:406:BMIN")
  field(DOL5, "XCOR:BPN27:406:BMIN")
  field(DOL6, "XCOR:BPN27:406:BMIN")
  field(LNK1, "XCOR:BPN27:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN27:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN27:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN27:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN27:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN27:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN27:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN27:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN27:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN27:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN27:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN27:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN27:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN27:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN27:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN27:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN27:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN27:406:EDES NPP MS")
  field(INPB, "XCOR:BPN27:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN28:206:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN28:206:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN28:206:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN28:206:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN28:206:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN28:206:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN28:206:EDES.PROC PP")
    field(LNK2, "XCOR:BPN28:206:EACT.PROC PP")
    field(LNK3, "XCOR:BPN28:206:EERR.DISA PP")
    field(LNK4, "XCOR:BPN28:206:ECON.PROC PP")
    field(LNK5, "XCOR:BPN28:206:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN28:206:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN28:206:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN28:206:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN28:206:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN28:206:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN28:206:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN28:206:BMAX")
  field(DOL2, "XCOR:BPN28:206:BMAX")
  field(DOL3, "XCOR:BPN28:206:BMAX")
  field(DOL4, "XCOR:BPN28:206:BMIN")
  field(DOL5, "XCOR:BPN28:206:BMIN")
  field(DOL6, "XCOR:BPN28:206:BMIN")
  field(LNK1, "XCOR:BPN28:206:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN28:206:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN28:206:BLEM.HOPR")
  field(LNK4, "XCOR:BPN28:206:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN28:206:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN28:206:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN28:206:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN28:206:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN28:206:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN28:206:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN28:206:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN28:206:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN28:206:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN28:206:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN28:206:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN28:206:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN28:206:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN28:206:EDES NPP MS")
  field(INPB, "XCOR:BPN28:206:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:BPN28:406:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:BPN28:406:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:BPN28:406:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:BPN28:406:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:BPN28:406:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:BPN28:406:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:BPN28:406:EDES.PROC PP")
    field(LNK2, "XCOR:BPN28:406:EACT.PROC PP")
    field(LNK3, "XCOR:BPN28:406:EERR.DISA PP")
    field(LNK4, "XCOR:BPN28:406:ECON.PROC PP")
    field(LNK5, "XCOR:BPN28:406:BMAGX.PROC PP")
    field(LNK6, "XCOR:BPN28:406:BMAGY.PROC PP")
    field(LNK7, "XCOR:BPN28:406:BLEM.PROC PP")
    field(LNK8, "XCOR:BPN28:406:BMOD.PROC PP")
    field(LNK9, "XCOR:BPN28:406:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:BPN28:406:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:BPN28:406:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:BPN28:406:BMAX")
  field(DOL2, "XCOR:BPN28:406:BMAX")
  field(DOL3, "XCOR:BPN28:406:BMAX")
  field(DOL4, "XCOR:BPN28:406:BMIN")
  field(DOL5, "XCOR:BPN28:406:BMIN")
  field(DOL6, "XCOR:BPN28:406:BMIN")
  field(LNK1, "XCOR:BPN28:406:BMAGX.HOPR")
  field(LNK2, "XCOR:BPN28:406:BMAGY.HOPR")
  field(LNK3, "XCOR:BPN28:406:BLEM.HOPR")
  field(LNK4, "XCOR:BPN28:406:BMAGX.LOPR PP")
  field(LNK5, "XCOR:BPN28:406:BMAGY.LOPR PP")
  field(LNK6, "XCOR:BPN28:406:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN28:406:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:BPN28:406:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:BPN28:406:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:BPN28:406:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:BPN28:406:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN28:406:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN28:406:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN28:406:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:BPN28:406:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:BPN28:406:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:BPN28:406:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:BPN28:406:EDES NPP MS")
  field(INPB, "XCOR:BPN28:406:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN13:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN13:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN13:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN13:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN13:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN13:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN13:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN13:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN13:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN13:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN13:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN13:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN13:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN13:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN13:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN13:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN13:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN13:409:BMAX")
  field(DOL2, "YCOR:BPN13:409:BMAX")
  field(DOL3, "YCOR:BPN13:409:BMAX")
  field(DOL4, "YCOR:BPN13:409:BMIN")
  field(DOL5, "YCOR:BPN13:409:BMIN")
  field(DOL6, "YCOR:BPN13:409:BMIN")
  field(LNK1, "YCOR:BPN13:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN13:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN13:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN13:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN13:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN13:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN13:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN13:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN13:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN13:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN13:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN13:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN13:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN13:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN13:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN13:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN13:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN13:409:EDES NPP MS")
  field(INPB, "YCOR:BPN13:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN14:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN14:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN14:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN14:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN14:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN14:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN14:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN14:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN14:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN14:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN14:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN14:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN14:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN14:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN14:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN14:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN14:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN14:409:BMAX")
  field(DOL2, "YCOR:BPN14:409:BMAX")
  field(DOL3, "YCOR:BPN14:409:BMAX")
  field(DOL4, "YCOR:BPN14:409:BMIN")
  field(DOL5, "YCOR:BPN14:409:BMIN")
  field(DOL6, "YCOR:BPN14:409:BMIN")
  field(LNK1, "YCOR:BPN14:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN14:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN14:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN14:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN14:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN14:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN14:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN14:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN14:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN14:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN14:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN14:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN14:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN14:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN14:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN14:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN14:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN14:409:EDES NPP MS")
  field(INPB, "YCOR:BPN14:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN15:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN15:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN15:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN15:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN15:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN15:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN15:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN15:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN15:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN15:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN15:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN15:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN15:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN15:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN15:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN15:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN15:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN15:409:BMAX")
  field(DOL2, "YCOR:BPN15:409:BMAX")
  field(DOL3, "YCOR:BPN15:409:BMAX")
  field(DOL4, "YCOR:BPN15:409:BMIN")
  field(DOL5, "YCOR:BPN15:409:BMIN")
  field(DOL6, "YCOR:BPN15:409:BMIN")
  field(LNK1, "YCOR:BPN15:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN15:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN15:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN15:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN15:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN15:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN15:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN15:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN15:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN15:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN15:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN15:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN15:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN15:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN15:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN15:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN15:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN15:409:EDES NPP MS")
  field(INPB, "YCOR:BPN15:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN16:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN16:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN16:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN16:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN16:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN16:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN16:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN16:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN16:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN16:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN16:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN16:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN16:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN16:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN16:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN16:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN16:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN16:409:BMAX")
  field(DOL2, "YCOR:BPN16:409:BMAX")
  field(DOL3, "YCOR:BPN16:409:BMAX")
  field(DOL4, "YCOR:BPN16:409:BMIN")
  field(DOL5, "YCOR:BPN16:409:BMIN")
  field(DOL6, "YCOR:BPN16:409:BMIN")
  field(LNK1, "YCOR:BPN16:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN16:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN16:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN16:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN16:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN16:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN16:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN16:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN16:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN16:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN16:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN16:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN16:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN16:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN16:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN16:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN16:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN16:409:EDES NPP MS")
  field(INPB, "YCOR:BPN16:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN17:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN17:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN17:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN17:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN17:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN17:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN17:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN17:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN17:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN17:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN17:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN17:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN17:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN17:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN17:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN17:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN17:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN17:409:BMAX")
  field(DOL2, "YCOR:BPN17:409:BMAX")
  field(DOL3, "YCOR:BPN17:409:BMAX")
  field(DOL4, "YCOR:BPN17:409:BMIN")
  field(DOL5, "YCOR:BPN17:409:BMIN")
  field(DOL6, "YCOR:BPN17:409:BMIN")
  field(LNK1, "YCOR:BPN17:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN17:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN17:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN17:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN17:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN17:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN17:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN17:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN17:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN17:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN17:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN17:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN17:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN17:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN17:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN17:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN17:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN17:409:EDES NPP MS")
  field(INPB, "YCOR:BPN17:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN18:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN18:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN18:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN18:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN18:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN18:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN18:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN18:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN18:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN18:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN18:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN18:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN18:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN18:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN18:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN18:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN18:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN18:409:BMAX")
  field(DOL2, "YCOR:BPN18:409:BMAX")
  field(DOL3, "YCOR:BPN18:409:BMAX")
  field(DOL4, "YCOR:BPN18:409:BMIN")
  field(DOL5, "YCOR:BPN18:409:BMIN")
  field(DOL6, "YCOR:BPN18:409:BMIN")
  field(LNK1, "YCOR:BPN18:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN18:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN18:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN18:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN18:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN18:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN18:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN18:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN18:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN18:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN18:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN18:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN18:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN18:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN18:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN18:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN18:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN18:409:EDES NPP MS")
  field(INPB, "YCOR:BPN18:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN19:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN19:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN19:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN19:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN19:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN19:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN19:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN19:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN19:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN19:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN19:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN19:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN19:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN19:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN19:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN19:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN19:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN19:409:BMAX")
  field(DOL2, "YCOR:BPN19:409:BMAX")
  field(DOL3, "YCOR:BPN19:409:BMAX")
  field(DOL4, "YCOR:BPN19:409:BMIN")
  field(DOL5, "YCOR:BPN19:409:BMIN")
  field(DOL6, "YCOR:BPN19:409:BMIN")
  field(LNK1, "YCOR:BPN19:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN19:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN19:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN19:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN19:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN19:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN19:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN19:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN19:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN19:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN19:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN19:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN19:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN19:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN19:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN19:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN19:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN19:409:EDES NPP MS")
  field(INPB, "YCOR:BPN19:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN20:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN20:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN20:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN20:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN20:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN20:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN20:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN20:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN20:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN20:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN20:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN20:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN20:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN20:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN20:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN20:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN20:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN20:409:BMAX")
  field(DOL2, "YCOR:BPN20:409:BMAX")
  field(DOL3, "YCOR:BPN20:409:BMAX")
  field(DOL4, "YCOR:BPN20:409:BMIN")
  field(DOL5, "YCOR:BPN20:409:BMIN")
  field(DOL6, "YCOR:BPN20:409:BMIN")
  field(LNK1, "YCOR:BPN20:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN20:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN20:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN20:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN20:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN20:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN20:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN20:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN20:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN20:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN20:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN20:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN20:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN20:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN20:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN20:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN20:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN20:409:EDES NPP MS")
  field(INPB, "YCOR:BPN20:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN21:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN21:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN21:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN21:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN21:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN21:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN21:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN21:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN21:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN21:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN21:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN21:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN21:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN21:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN21:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN21:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN21:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN21:409:BMAX")
  field(DOL2, "YCOR:BPN21:409:BMAX")
  field(DOL3, "YCOR:BPN21:409:BMAX")
  field(DOL4, "YCOR:BPN21:409:BMIN")
  field(DOL5, "YCOR:BPN21:409:BMIN")
  field(DOL6, "YCOR:BPN21:409:BMIN")
  field(LNK1, "YCOR:BPN21:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN21:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN21:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN21:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN21:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN21:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN21:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN21:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN21:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN21:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN21:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN21:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN21:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN21:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN21:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN21:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN21:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN21:409:EDES NPP MS")
  field(INPB, "YCOR:BPN21:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN22:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN22:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN22:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN22:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN22:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN22:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN22:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN22:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN22:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN22:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN22:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN22:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN22:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN22:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN22:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN22:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN22:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN22:409:BMAX")
  field(DOL2, "YCOR:BPN22:409:BMAX")
  field(DOL3, "YCOR:BPN22:409:BMAX")
  field(DOL4, "YCOR:BPN22:409:BMIN")
  field(DOL5, "YCOR:BPN22:409:BMIN")
  field(DOL6, "YCOR:BPN22:409:BMIN")
  field(LNK1, "YCOR:BPN22:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN22:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN22:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN22:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN22:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN22:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN22:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN22:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN22:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN22:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN22:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN22:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN22:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN22:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN22:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN22:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN22:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN22:409:EDES NPP MS")
  field(INPB, "YCOR:BPN22:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN23:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN23:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN23:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN23:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN23:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN23:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN23:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN23:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN23:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN23:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN23:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN23:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN23:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN23:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN23:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN23:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN23:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN23:409:BMAX")
  field(DOL2, "YCOR:BPN23:409:BMAX")
  field(DOL3, "YCOR:BPN23:409:BMAX")
  field(DOL4, "YCOR:BPN23:409:BMIN")
  field(DOL5, "YCOR:BPN23:409:BMIN")
  field(DOL6, "YCOR:BPN23:409:BMIN")
  field(LNK1, "YCOR:BPN23:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN23:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN23:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN23:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN23:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN23:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN23:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN23:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN23:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN23:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN23:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN23:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN23:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN23:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN23:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN23:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN23:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN23:409:EDES NPP MS")
  field(INPB, "YCOR:BPN23:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN24:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN24:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN24:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN24:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN24:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN24:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN24:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN24:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN24:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN24:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN24:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN24:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN24:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN24:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN24:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN24:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN24:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN24:409:BMAX")
  field(DOL2, "YCOR:BPN24:409:BMAX")
  field(DOL3, "YCOR:BPN24:409:BMAX")
  field(DOL4, "YCOR:BPN24:409:BMIN")
  field(DOL5, "YCOR:BPN24:409:BMIN")
  field(DOL6, "YCOR:BPN24:409:BMIN")
  field(LNK1, "YCOR:BPN24:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN24:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN24:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN24:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN24:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN24:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN24:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN24:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN24:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN24:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN24:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN24:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN24:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN24:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN24:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN24:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN24:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN24:409:EDES NPP MS")
  field(INPB, "YCOR:BPN24:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN25:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN25:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN25:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN25:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN25:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN25:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN25:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN25:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN25:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN25:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN25:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN25:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN25:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN25:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN25:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN25:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN25:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN25:409:BMAX")
  field(DOL2, "YCOR:BPN25:409:BMAX")
  field(DOL3, "YCOR:BPN25:409:BMAX")
  field(DOL4, "YCOR:BPN25:409:BMIN")
  field(DOL5, "YCOR:BPN25:409:BMIN")
  field(DOL6, "YCOR:BPN25:409:BMIN")
  field(LNK1, "YCOR:BPN25:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN25:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN25:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN25:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN25:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN25:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN25:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN25:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN25:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN25:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN25:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN25:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN25:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN25:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN25:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN25:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN25:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN25:409:EDES NPP MS")
  field(INPB, "YCOR:BPN25:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN26:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN26:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN26:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN26:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN26:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN26:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN26:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN26:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN26:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN26:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN26:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN26:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN26:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN26:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN26:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN26:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN26:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN26:409:BMAX")
  field(DOL2, "YCOR:BPN26:409:BMAX")
  field(DOL3, "YCOR:BPN26:409:BMAX")
  field(DOL4, "YCOR:BPN26:409:BMIN")
  field(DOL5, "YCOR:BPN26:409:BMIN")
  field(DOL6, "YCOR:BPN26:409:BMIN")
  field(LNK1, "YCOR:BPN26:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN26:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN26:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN26:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN26:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN26:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN26:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN26:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN26:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN26:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN26:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN26:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN26:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN26:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN26:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN26:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN26:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN26:409:EDES NPP MS")
  field(INPB, "YCOR:BPN26:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN27:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN27:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN27:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN27:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN27:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN27:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN27:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN27:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN27:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN27:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN27:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN27:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN27:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN27:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN27:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN27:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN27:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN27:409:BMAX")
  field(DOL2, "YCOR:BPN27:409:BMAX")
  field(DOL3, "YCOR:BPN27:409:BMAX")
  field(DOL4, "YCOR:BPN27:409:BMIN")
  field(DOL5, "YCOR:BPN27:409:BMIN")
  field(DOL6, "YCOR:BPN27:409:BMIN")
  field(LNK1, "YCOR:BPN27:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN27:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN27:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN27:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN27:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN27:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN27:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN27:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN27:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN27:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN27:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN27:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN27:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN27:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN27:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN27:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN27:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN27:409:EDES NPP MS")
  field(INPB, "YCOR:BPN27:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN28:209:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN28:209:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN28:209:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN28:209:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN28:209:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN28:209:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN28:209:EDES.PROC PP")
    field(LNK2, "YCOR:BPN28:209:EACT.PROC PP")
    field(LNK3, "YCOR:BPN28:209:EERR.DISA PP")
    field(LNK4, "YCOR:BPN28:209:ECON.PROC PP")
    field(LNK5, "YCOR:BPN28:209:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN28:209:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN28:209:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN28:209:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN28:209:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN28:209:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN28:209:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN28:209:BMAX")
  field(DOL2, "YCOR:BPN28:209:BMAX")
  field(DOL3, "YCOR:BPN28:209:BMAX")
  field(DOL4, "YCOR:BPN28:209:BMIN")
  field(DOL5, "YCOR:BPN28:209:BMIN")
  field(DOL6, "YCOR:BPN28:209:BMIN")
  field(LNK1, "YCOR:BPN28:209:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN28:209:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN28:209:BLEM.HOPR")
  field(LNK4, "YCOR:BPN28:209:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN28:209:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN28:209:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN28:209:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN28:209:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN28:209:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN28:209:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN28:209:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN28:209:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN28:209:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN28:209:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN28:209:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN28:209:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN28:209:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN28:209:EDES NPP MS")
  field(INPB, "YCOR:BPN28:209:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:BPN28:409:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:BPN28:409:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:BPN28:409:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:BPN28:409:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:BPN28:409:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:BPN28:409:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:BPN28:409:EDES.PROC PP")
    field(LNK2, "YCOR:BPN28:409:EACT.PROC PP")
    field(LNK3, "YCOR:BPN28:409:EERR.DISA PP")
    field(LNK4, "YCOR:BPN28:409:ECON.PROC PP")
    field(LNK5, "YCOR:BPN28:409:BMAGX.PROC PP")
    field(LNK6, "YCOR:BPN28:409:BMAGY.PROC PP")
    field(LNK7, "YCOR:BPN28:409:BLEM.PROC PP")
    field(LNK8, "YCOR:BPN28:409:BMOD.PROC PP")
    field(LNK9, "YCOR:BPN28:409:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:BPN28:409:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:BPN28:409:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:BPN28:409:BMAX")
  field(DOL2, "YCOR:BPN28:409:BMAX")
  field(DOL3, "YCOR:BPN28:409:BMAX")
  field(DOL4, "YCOR:BPN28:409:BMIN")
  field(DOL5, "YCOR:BPN28:409:BMIN")
  field(DOL6, "YCOR:BPN28:409:BMIN")
  field(LNK1, "YCOR:BPN28:409:BMAGX.HOPR")
  field(LNK2, "YCOR:BPN28:409:BMAGY.HOPR")
  field(LNK3, "YCOR:BPN28:409:BLEM.HOPR")
  field(LNK4, "YCOR:BPN28:409:BMAGX.LOPR PP")
  field(LNK5, "YCOR:BPN28:409:BMAGY.LOPR PP")
  field(LNK6, "YCOR:BPN28:409:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN28:409:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:BPN28:409:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:BPN28:409:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:BPN28:409:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:BPN28:409:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN28:409:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN28:409:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN28:409:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:BPN28:409:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:BPN28:409:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:BPN28:409:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:BPN28:409:EDES NPP MS")
  field(INPB, "YCOR:BPN28:409:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:HTR:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "LGPS:HTR:1:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:HTR:1:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:HTR:1:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:HTR:1:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:HTR:1:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:HTR:1:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:HTR:1:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:HTR:1:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:HTR:1:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:HTR:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:HTR:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:HTR:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:HTR:1:EDES.PROC PP")
    field(LNK2, "LGPS:HTR:1:EACT.PROC PP")
    field(LNK3, "LGPS:HTR:1:EERR.DISA PP")
    field(LNK4, "LGPS:HTR:1:ECON.PROC PP")
    field(LNK5, "LGPS:HTR:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:HTR:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:HTR:1:BLEM.PROC PP")
    field(LNK8, "LGPS:HTR:1:BMOD.PROC PP")
    field(LNK9, "LGPS:HTR:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:HTR:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:HTR:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:HTR:1:BMAX")
  field(DOL2, "LGPS:HTR:1:BMAX")
  field(DOL3, "LGPS:HTR:1:BMAX")
  field(DOL4, "LGPS:HTR:1:BMIN")
  field(DOL5, "LGPS:HTR:1:BMIN")
  field(DOL6, "LGPS:HTR:1:BMIN")
  field(LNK1, "LGPS:HTR:1:BMAGX.HOPR")
  field(LNK2, "LGPS:HTR:1:BMAGY.HOPR")
  field(LNK3, "LGPS:HTR:1:BLEM.HOPR")
  field(LNK4, "LGPS:HTR:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:HTR:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:HTR:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:HTR:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:HTR:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:HTR:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:HTR:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:HTR:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:HTR:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:HTR:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:HTR:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:HTR:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:HTR:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:HTR:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:HTR:1:EDES NPP MS")
  field(INPB, "LGPS:HTR:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:HTR:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "LGPS:HTR:2:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:HTR:2:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:HTR:2:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:HTR:2:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:HTR:2:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:HTR:2:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:HTR:2:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:HTR:2:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:HTR:2:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:HTR:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:HTR:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:HTR:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:HTR:2:EDES.PROC PP")
    field(LNK2, "LGPS:HTR:2:EACT.PROC PP")
    field(LNK3, "LGPS:HTR:2:EERR.DISA PP")
    field(LNK4, "LGPS:HTR:2:ECON.PROC PP")
    field(LNK5, "LGPS:HTR:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:HTR:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:HTR:2:BLEM.PROC PP")
    field(LNK8, "LGPS:HTR:2:BMOD.PROC PP")
    field(LNK9, "LGPS:HTR:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:HTR:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:HTR:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:HTR:2:BMAX")
  field(DOL2, "LGPS:HTR:2:BMAX")
  field(DOL3, "LGPS:HTR:2:BMAX")
  field(DOL4, "LGPS:HTR:2:BMIN")
  field(DOL5, "LGPS:HTR:2:BMIN")
  field(DOL6, "LGPS:HTR:2:BMIN")
  field(LNK1, "LGPS:HTR:2:BMAGX.HOPR")
  field(LNK2, "LGPS:HTR:2:BMAGY.HOPR")
  field(LNK3, "LGPS:HTR:2:BLEM.HOPR")
  field(LNK4, "LGPS:HTR:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:HTR:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:HTR:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:HTR:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:HTR:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:HTR:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:HTR:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:HTR:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:HTR:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:HTR:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:HTR:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:HTR:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:HTR:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:HTR:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:HTR:2:EDES NPP MS")
  field(INPB, "LGPS:HTR:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BC1B:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BC1B:1:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BC1B:1:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BC1B:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BC1B:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BC1B:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BC1B:1:EDES.PROC PP")
    field(LNK2, "LGPS:BC1B:1:EACT.PROC PP")
    field(LNK3, "LGPS:BC1B:1:EERR.DISA PP")
    field(LNK4, "LGPS:BC1B:1:ECON.PROC PP")
    field(LNK5, "LGPS:BC1B:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BC1B:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BC1B:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BC1B:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BC1B:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BC1B:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BC1B:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BC1B:1:BMAX")
  field(DOL2, "LGPS:BC1B:1:BMAX")
  field(DOL3, "LGPS:BC1B:1:BMAX")
  field(DOL4, "LGPS:BC1B:1:BMIN")
  field(DOL5, "LGPS:BC1B:1:BMIN")
  field(DOL6, "LGPS:BC1B:1:BMIN")
  field(LNK1, "LGPS:BC1B:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BC1B:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BC1B:1:BLEM.HOPR")
  field(LNK4, "LGPS:BC1B:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BC1B:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BC1B:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BC1B:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BC1B:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BC1B:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BC1B:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BC1B:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BC1B:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BC1B:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BC1B:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BC1B:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BC1B:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BC1B:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BC1B:1:EDES NPP MS")
  field(INPB, "LGPS:BC1B:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BC2B:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BC2B:1:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BC2B:1:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BC2B:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BC2B:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BC2B:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BC2B:1:EDES.PROC PP")
    field(LNK2, "LGPS:BC2B:1:EACT.PROC PP")
    field(LNK3, "LGPS:BC2B:1:EERR.DISA PP")
    field(LNK4, "LGPS:BC2B:1:ECON.PROC PP")
    field(LNK5, "LGPS:BC2B:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BC2B:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BC2B:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BC2B:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BC2B:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BC2B:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BC2B:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BC2B:1:BMAX")
  field(DOL2, "LGPS:BC2B:1:BMAX")
  field(DOL3, "LGPS:BC2B:1:BMAX")
  field(DOL4, "LGPS:BC2B:1:BMIN")
  field(DOL5, "LGPS:BC2B:1:BMIN")
  field(DOL6, "LGPS:BC2B:1:BMIN")
  field(LNK1, "LGPS:BC2B:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BC2B:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BC2B:1:BLEM.HOPR")
  field(LNK4, "LGPS:BC2B:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BC2B:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BC2B:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BC2B:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BC2B:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BC2B:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BC2B:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BC2B:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BC2B:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BC2B:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BC2B:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BC2B:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BC2B:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BC2B:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BC2B:1:EDES NPP MS")
  field(INPB, "LGPS:BC2B:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:EXT:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EXT:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EXT:1:CTRL.RVAL")
  field(LNK1, "LGPS:EXT:1:FUNC CA PP")
  field(DOL2, "MGNT:EXT:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:EXT:1:FUNC CA PP")
  field(DOL3, "MGNT:EXT:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:EXT:1:FUNC CA PP")
  field(DOL4, "MGNT:EXT:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:EXT:1:FUNC CA PP")
  field(DOL5, "MGNT:EXT:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:EXT:1:FUNC CA PP")
  field(DOL6, "MGNT:EXT:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:EXT:1:FUNC CA PP")
  field(DOL7, "MGNT:EXT:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:EXT:1:FUNC CA PP")
  field(DOL8, "MGNT:EXT:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:EXT:1:FUNC CA PP")
  field(DOL9, "MGNT:EXT:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:EXT:1:FUNC CA PP")
  field(DOLA, "MGNT:EXT:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:EXT:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:EXT:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:EXT:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:EXT:1:EDES.PROC PP")
    field(LNK2, "LGPS:EXT:1:EACT.PROC PP")
    field(LNK3, "LGPS:EXT:1:EERR.DISA PP")
    field(LNK4, "LGPS:EXT:1:ECON.PROC PP")
    field(LNK5, "LGPS:EXT:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:EXT:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:EXT:1:BLEM.PROC PP")
    field(LNK8, "LGPS:EXT:1:BMOD.PROC PP")
    field(LNK9, "LGPS:EXT:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:EXT:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:EXT:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:EXT:1:BMAX")
  field(DOL2, "LGPS:EXT:1:BMAX")
  field(DOL3, "LGPS:EXT:1:BMAX")
  field(DOL4, "LGPS:EXT:1:BMIN")
  field(DOL5, "LGPS:EXT:1:BMIN")
  field(DOL6, "LGPS:EXT:1:BMIN")
  field(LNK1, "LGPS:EXT:1:BMAGX.HOPR")
  field(LNK2, "LGPS:EXT:1:BMAGY.HOPR")
  field(LNK3, "LGPS:EXT:1:BLEM.HOPR")
  field(LNK4, "LGPS:EXT:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:EXT:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:EXT:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:EXT:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:EXT:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:EXT:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:EXT:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:EXT:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:EXT:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:EXT:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:EXT:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:EXT:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:EXT:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:EXT:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:EXT:1:EDES NPP MS")
  field(INPB, "LGPS:EXT:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:EXT:2:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:EXT:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:EXT:1:CTRL.RVAL")
  field(LNK1, "LGPS:EXT:2:FUNC CA PP")
  field(DOL2, "MGNT:EXT:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:EXT:2:FUNC CA PP")
  field(DOL3, "MGNT:EXT:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:EXT:2:FUNC CA PP")
  field(DOL4, "MGNT:EXT:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:EXT:2:FUNC CA PP")
  field(DOL5, "MGNT:EXT:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:EXT:2:FUNC CA PP")
  field(DOL6, "MGNT:EXT:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:EXT:2:FUNC CA PP")
  field(DOL7, "MGNT:EXT:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:EXT:2:FUNC CA PP")
  field(DOL8, "MGNT:EXT:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:EXT:2:FUNC CA PP")
  field(DOL9, "MGNT:EXT:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:EXT:2:FUNC CA PP")
  field(DOLA, "MGNT:EXT:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:EXT:2:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:EXT:2:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:EXT:2:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:EXT:2:EDES.PROC PP")
    field(LNK2, "LGPS:EXT:2:EACT.PROC PP")
    field(LNK3, "LGPS:EXT:2:EERR.DISA PP")
    field(LNK4, "LGPS:EXT:2:ECON.PROC PP")
    field(LNK5, "LGPS:EXT:2:BMAGX.PROC PP")
    field(LNK6, "LGPS:EXT:2:BMAGY.PROC PP")
    field(LNK7, "LGPS:EXT:2:BLEM.PROC PP")
    field(LNK8, "LGPS:EXT:2:BMOD.PROC PP")
    field(LNK9, "LGPS:EXT:2:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:EXT:2:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:EXT:2:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:EXT:2:BMAX")
  field(DOL2, "LGPS:EXT:2:BMAX")
  field(DOL3, "LGPS:EXT:2:BMAX")
  field(DOL4, "LGPS:EXT:2:BMIN")
  field(DOL5, "LGPS:EXT:2:BMIN")
  field(DOL6, "LGPS:EXT:2:BMIN")
  field(LNK1, "LGPS:EXT:2:BMAGX.HOPR")
  field(LNK2, "LGPS:EXT:2:BMAGY.HOPR")
  field(LNK3, "LGPS:EXT:2:BLEM.HOPR")
  field(LNK4, "LGPS:EXT:2:BMAGX.LOPR PP")
  field(LNK5, "LGPS:EXT:2:BMAGY.LOPR PP")
  field(LNK6, "LGPS:EXT:2:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:EXT:2:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:EXT:2:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:EXT:2:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:EXT:2:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:EXT:2:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:EXT:2:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:EXT:2:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:EXT:2:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:EXT:2:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:EXT:2:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:EXT:2:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:EXT:2:EDES NPP MS")
  field(INPB, "LGPS:EXT:2:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BPN10:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BPN10:1:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BPN10:1:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BPN10:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BPN10:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BPN10:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BPN10:1:EDES.PROC PP")
    field(LNK2, "LGPS:BPN10:1:EACT.PROC PP")
    field(LNK3, "LGPS:BPN10:1:EERR.DISA PP")
    field(LNK4, "LGPS:BPN10:1:ECON.PROC PP")
    field(LNK5, "LGPS:BPN10:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BPN10:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BPN10:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BPN10:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BPN10:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BPN10:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BPN10:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BPN10:1:BMAX")
  field(DOL2, "LGPS:BPN10:1:BMAX")
  field(DOL3, "LGPS:BPN10:1:BMAX")
  field(DOL4, "LGPS:BPN10:1:BMIN")
  field(DOL5, "LGPS:BPN10:1:BMIN")
  field(DOL6, "LGPS:BPN10:1:BMIN")
  field(LNK1, "LGPS:BPN10:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BPN10:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BPN10:1:BLEM.HOPR")
  field(LNK4, "LGPS:BPN10:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BPN10:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BPN10:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN10:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN10:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BPN10:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BPN10:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BPN10:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN10:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN10:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN10:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN10:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN10:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BPN10:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BPN10:1:EDES NPP MS")
  field(INPB, "LGPS:BPN10:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BPN17:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BPN17:1:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BPN17:1:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BPN17:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BPN17:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BPN17:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BPN17:1:EDES.PROC PP")
    field(LNK2, "LGPS:BPN17:1:EACT.PROC PP")
    field(LNK3, "LGPS:BPN17:1:EERR.DISA PP")
    field(LNK4, "LGPS:BPN17:1:ECON.PROC PP")
    field(LNK5, "LGPS:BPN17:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BPN17:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BPN17:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BPN17:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BPN17:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BPN17:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BPN17:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BPN17:1:BMAX")
  field(DOL2, "LGPS:BPN17:1:BMAX")
  field(DOL3, "LGPS:BPN17:1:BMAX")
  field(DOL4, "LGPS:BPN17:1:BMIN")
  field(DOL5, "LGPS:BPN17:1:BMIN")
  field(DOL6, "LGPS:BPN17:1:BMIN")
  field(LNK1, "LGPS:BPN17:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BPN17:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BPN17:1:BLEM.HOPR")
  field(LNK4, "LGPS:BPN17:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BPN17:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BPN17:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN17:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN17:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BPN17:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BPN17:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BPN17:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN17:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN17:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN17:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN17:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN17:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BPN17:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BPN17:1:EDES NPP MS")
  field(INPB, "LGPS:BPN17:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BPN21:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BPN21:1:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BPN21:1:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BPN21:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BPN21:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BPN21:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BPN21:1:EDES.PROC PP")
    field(LNK2, "LGPS:BPN21:1:EACT.PROC PP")
    field(LNK3, "LGPS:BPN21:1:EERR.DISA PP")
    field(LNK4, "LGPS:BPN21:1:ECON.PROC PP")
    field(LNK5, "LGPS:BPN21:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BPN21:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BPN21:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BPN21:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BPN21:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BPN21:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BPN21:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BPN21:1:BMAX")
  field(DOL2, "LGPS:BPN21:1:BMAX")
  field(DOL3, "LGPS:BPN21:1:BMAX")
  field(DOL4, "LGPS:BPN21:1:BMIN")
  field(DOL5, "LGPS:BPN21:1:BMIN")
  field(DOL6, "LGPS:BPN21:1:BMIN")
  field(LNK1, "LGPS:BPN21:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BPN21:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BPN21:1:BLEM.HOPR")
  field(LNK4, "LGPS:BPN21:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BPN21:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BPN21:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN21:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN21:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BPN21:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BPN21:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BPN21:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN21:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN21:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN21:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN21:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN21:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BPN21:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BPN21:1:EDES NPP MS")
  field(INPB, "LGPS:BPN21:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:BPN25:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BYP:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BYP:1:CTRL.RVAL")
  field(LNK1, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL2, "MGNT:BYP:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL3, "MGNT:BYP:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL4, "MGNT:BYP:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL5, "MGNT:BYP:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL6, "MGNT:BYP:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL7, "MGNT:BYP:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL8, "MGNT:BYP:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:BPN25:1:FUNC CA PP")
  field(DOL9, "MGNT:BYP:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:BPN25:1:FUNC CA PP")
  field(DOLA, "MGNT:BYP:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:BPN25:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:BPN25:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:BPN25:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:BPN25:1:EDES.PROC PP")
    field(LNK2, "LGPS:BPN25:1:EACT.PROC PP")
    field(LNK3, "LGPS:BPN25:1:EERR.DISA PP")
    field(LNK4, "LGPS:BPN25:1:ECON.PROC PP")
    field(LNK5, "LGPS:BPN25:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:BPN25:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:BPN25:1:BLEM.PROC PP")
    field(LNK8, "LGPS:BPN25:1:BMOD.PROC PP")
    field(LNK9, "LGPS:BPN25:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:BPN25:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:BPN25:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:BPN25:1:BMAX")
  field(DOL2, "LGPS:BPN25:1:BMAX")
  field(DOL3, "LGPS:BPN25:1:BMAX")
  field(DOL4, "LGPS:BPN25:1:BMIN")
  field(DOL5, "LGPS:BPN25:1:BMIN")
  field(DOL6, "LGPS:BPN25:1:BMIN")
  field(LNK1, "LGPS:BPN25:1:BMAGX.HOPR")
  field(LNK2, "LGPS:BPN25:1:BMAGY.HOPR")
  field(LNK3, "LGPS:BPN25:1:BLEM.HOPR")
  field(LNK4, "LGPS:BPN25:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:BPN25:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:BPN25:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN25:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:BPN25:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:BPN25:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:BPN25:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:BPN25:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN25:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN25:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN25:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:BPN25:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:BPN25:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:BPN25:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:BPN25:1:EDES NPP MS")
  field(INPB, "LGPS:BPN25:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:HTR:480:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BEND:HTR:480:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:HTR:480:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:HTR:480:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:HTR:480:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:HTR:480:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:HTR:480:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:HTR:480:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:HTR:480:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:HTR:480:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:HTR:480:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:HTR:480:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:HTR:480:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:HTR:480:EDES.PROC PP")
    field(LNK2, "BEND:HTR:480:EACT.PROC PP")
    field(LNK3, "BEND:HTR:480:EERR.DISA PP")
    field(LNK4, "BEND:HTR:480:ECON.PROC PP")
    field(LNK5, "BEND:HTR:480:BMAGX.PROC PP")
    field(LNK6, "BEND:HTR:480:BMAGY.PROC PP")
    field(LNK7, "BEND:HTR:480:BLEM.PROC PP")
    field(LNK8, "BEND:HTR:480:BMOD.PROC PP")
    field(LNK9, "BEND:HTR:480:EDESSAVE.PROC PP")
    field(LNKA, "BEND:HTR:480:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:HTR:480:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:HTR:480:BMAX")
  field(DOL2, "BEND:HTR:480:BMAX")
  field(DOL3, "BEND:HTR:480:BMAX")
  field(DOL4, "BEND:HTR:480:BMIN")
  field(DOL5, "BEND:HTR:480:BMIN")
  field(DOL6, "BEND:HTR:480:BMIN")
  field(LNK1, "BEND:HTR:480:BMAGX.HOPR")
  field(LNK2, "BEND:HTR:480:BMAGY.HOPR")
  field(LNK3, "BEND:HTR:480:BLEM.HOPR")
  field(LNK4, "BEND:HTR:480:BMAGX.LOPR PP")
  field(LNK5, "BEND:HTR:480:BMAGY.LOPR PP")
  field(LNK6, "BEND:HTR:480:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:480:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:480:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:HTR:480:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:HTR:480:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:HTR:480:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:480:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:HTR:600:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:480:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:HTR:600:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:HTR:480:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:480:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:HTR:600:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:HTR:480:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:HTR:480:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:HTR:480:EDES NPP MS")
  field(INPB, "BEND:HTR:480:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:HTR:700:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BEND:HTR:700:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:HTR:700:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:HTR:700:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:HTR:700:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:HTR:700:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:HTR:700:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:HTR:700:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:HTR:700:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:HTR:700:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:HTR:700:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:HTR:700:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:HTR:700:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:HTR:700:EDES.PROC PP")
    field(LNK2, "BEND:HTR:700:EACT.PROC PP")
    field(LNK3, "BEND:HTR:700:EERR.DISA PP")
    field(LNK4, "BEND:HTR:700:ECON.PROC PP")
    field(LNK5, "BEND:HTR:700:BMAGX.PROC PP")
    field(LNK6, "BEND:HTR:700:BMAGY.PROC PP")
    field(LNK7, "BEND:HTR:700:BLEM.PROC PP")
    field(LNK8, "BEND:HTR:700:BMOD.PROC PP")
    field(LNK9, "BEND:HTR:700:EDESSAVE.PROC PP")
    field(LNKA, "BEND:HTR:700:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:HTR:700:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:HTR:700:BMAX")
  field(DOL2, "BEND:HTR:700:BMAX")
  field(DOL3, "BEND:HTR:700:BMAX")
  field(DOL4, "BEND:HTR:700:BMIN")
  field(DOL5, "BEND:HTR:700:BMIN")
  field(DOL6, "BEND:HTR:700:BMIN")
  field(LNK1, "BEND:HTR:700:BMAGX.HOPR")
  field(LNK2, "BEND:HTR:700:BMAGY.HOPR")
  field(LNK3, "BEND:HTR:700:BLEM.HOPR")
  field(LNK4, "BEND:HTR:700:BMAGX.LOPR PP")
  field(LNK5, "BEND:HTR:700:BMAGY.LOPR PP")
  field(LNK6, "BEND:HTR:700:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:700:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:700:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:HTR:700:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:HTR:700:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:HTR:700:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:700:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:HTR:600:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:700:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:HTR:600:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:HTR:700:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:700:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:HTR:600:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:HTR:700:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:HTR:700:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:HTR:700:EDES NPP MS")
  field(INPB, "BEND:HTR:700:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:HTR:820:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:HTR:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:HTR:1:CTRL.RVAL")
  field(LNK1, "BEND:HTR:820:FUNC CA PP")
  field(DOL2, "MGNT:HTR:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:HTR:820:FUNC CA PP")
  field(DOL3, "MGNT:HTR:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:HTR:820:FUNC CA PP")
  field(DOL4, "MGNT:HTR:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:HTR:820:FUNC CA PP")
  field(DOL5, "MGNT:HTR:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:HTR:820:FUNC CA PP")
  field(DOL6, "MGNT:HTR:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:HTR:820:FUNC CA PP")
  field(DOL7, "MGNT:HTR:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:HTR:820:FUNC CA PP")
  field(DOL8, "MGNT:HTR:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:HTR:820:FUNC CA PP")
  field(DOL9, "MGNT:HTR:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:HTR:820:FUNC CA PP")
  field(DOLA, "MGNT:HTR:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:HTR:820:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:HTR:820:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:HTR:820:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:HTR:820:EDES.PROC PP")
    field(LNK2, "BEND:HTR:820:EACT.PROC PP")
    field(LNK3, "BEND:HTR:820:EERR.DISA PP")
    field(LNK4, "BEND:HTR:820:ECON.PROC PP")
    field(LNK5, "BEND:HTR:820:BMAGX.PROC PP")
    field(LNK6, "BEND:HTR:820:BMAGY.PROC PP")
    field(LNK7, "BEND:HTR:820:BLEM.PROC PP")
    field(LNK8, "BEND:HTR:820:BMOD.PROC PP")
    field(LNK9, "BEND:HTR:820:EDESSAVE.PROC PP")
    field(LNKA, "BEND:HTR:820:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:HTR:820:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:HTR:820:BMAX")
  field(DOL2, "BEND:HTR:820:BMAX")
  field(DOL3, "BEND:HTR:820:BMAX")
  field(DOL4, "BEND:HTR:820:BMIN")
  field(DOL5, "BEND:HTR:820:BMIN")
  field(DOL6, "BEND:HTR:820:BMIN")
  field(LNK1, "BEND:HTR:820:BMAGX.HOPR")
  field(LNK2, "BEND:HTR:820:BMAGY.HOPR")
  field(LNK3, "BEND:HTR:820:BLEM.HOPR")
  field(LNK4, "BEND:HTR:820:BMAGX.LOPR PP")
  field(LNK5, "BEND:HTR:820:BMAGY.LOPR PP")
  field(LNK6, "BEND:HTR:820:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:820:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:HTR:820:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:HTR:820:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:HTR:820:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:HTR:820:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:820:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:HTR:600:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:820:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:HTR:600:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:HTR:820:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:HTR:820:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:HTR:600:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:HTR:820:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:HTR:820:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:HTR:820:EDES NPP MS")
  field(INPB, "BEND:HTR:820:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC1B:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC1B:200:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC1B:200:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC1B:200:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC1B:200:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC1B:200:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC1B:200:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC1B:200:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC1B:200:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC1B:200:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC1B:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC1B:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC1B:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC1B:200:EDES.PROC PP")
    field(LNK2, "BEND:BC1B:200:EACT.PROC PP")
    field(LNK3, "BEND:BC1B:200:EERR.DISA PP")
    field(LNK4, "BEND:BC1B:200:ECON.PROC PP")
    field(LNK5, "BEND:BC1B:200:BMAGX.PROC PP")
    field(LNK6, "BEND:BC1B:200:BMAGY.PROC PP")
    field(LNK7, "BEND:BC1B:200:BLEM.PROC PP")
    field(LNK8, "BEND:BC1B:200:BMOD.PROC PP")
    field(LNK9, "BEND:BC1B:200:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC1B:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC1B:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC1B:200:BMAX")
  field(DOL2, "BEND:BC1B:200:BMAX")
  field(DOL3, "BEND:BC1B:200:BMAX")
  field(DOL4, "BEND:BC1B:200:BMIN")
  field(DOL5, "BEND:BC1B:200:BMIN")
  field(DOL6, "BEND:BC1B:200:BMIN")
  field(LNK1, "BEND:BC1B:200:BMAGX.HOPR")
  field(LNK2, "BEND:BC1B:200:BMAGY.HOPR")
  field(LNK3, "BEND:BC1B:200:BLEM.HOPR")
  field(LNK4, "BEND:BC1B:200:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC1B:200:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC1B:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC1B:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC1B:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC1B:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:BC1B:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:BC1B:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC1B:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:BC1B:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC1B:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC1B:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC1B:200:EDES NPP MS")
  field(INPB, "BEND:BC1B:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC1B:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC1B:600:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC1B:600:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC1B:600:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC1B:600:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC1B:600:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC1B:600:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC1B:600:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC1B:600:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC1B:600:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC1B:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC1B:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC1B:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC1B:600:EDES.PROC PP")
    field(LNK2, "BEND:BC1B:600:EACT.PROC PP")
    field(LNK3, "BEND:BC1B:600:EERR.DISA PP")
    field(LNK4, "BEND:BC1B:600:ECON.PROC PP")
    field(LNK5, "BEND:BC1B:600:BMAGX.PROC PP")
    field(LNK6, "BEND:BC1B:600:BMAGY.PROC PP")
    field(LNK7, "BEND:BC1B:600:BLEM.PROC PP")
    field(LNK8, "BEND:BC1B:600:BMOD.PROC PP")
    field(LNK9, "BEND:BC1B:600:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC1B:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC1B:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC1B:600:BMAX")
  field(DOL2, "BEND:BC1B:600:BMAX")
  field(DOL3, "BEND:BC1B:600:BMAX")
  field(DOL4, "BEND:BC1B:600:BMIN")
  field(DOL5, "BEND:BC1B:600:BMIN")
  field(DOL6, "BEND:BC1B:600:BMIN")
  field(LNK1, "BEND:BC1B:600:BMAGX.HOPR")
  field(LNK2, "BEND:BC1B:600:BMAGY.HOPR")
  field(LNK3, "BEND:BC1B:600:BLEM.HOPR")
  field(LNK4, "BEND:BC1B:600:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC1B:600:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC1B:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC1B:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC1B:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC1B:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:BC1B:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:BC1B:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC1B:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:BC1B:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC1B:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC1B:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC1B:600:EDES NPP MS")
  field(INPB, "BEND:BC1B:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC1B:800:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC1B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC1B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC1B:800:FUNC CA PP")
  field(DOL2, "MGNT:BC1B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC1B:800:FUNC CA PP")
  field(DOL3, "MGNT:BC1B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC1B:800:FUNC CA PP")
  field(DOL4, "MGNT:BC1B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC1B:800:FUNC CA PP")
  field(DOL5, "MGNT:BC1B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC1B:800:FUNC CA PP")
  field(DOL6, "MGNT:BC1B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC1B:800:FUNC CA PP")
  field(DOL7, "MGNT:BC1B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC1B:800:FUNC CA PP")
  field(DOL8, "MGNT:BC1B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC1B:800:FUNC CA PP")
  field(DOL9, "MGNT:BC1B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC1B:800:FUNC CA PP")
  field(DOLA, "MGNT:BC1B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC1B:800:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC1B:800:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC1B:800:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC1B:800:EDES.PROC PP")
    field(LNK2, "BEND:BC1B:800:EACT.PROC PP")
    field(LNK3, "BEND:BC1B:800:EERR.DISA PP")
    field(LNK4, "BEND:BC1B:800:ECON.PROC PP")
    field(LNK5, "BEND:BC1B:800:BMAGX.PROC PP")
    field(LNK6, "BEND:BC1B:800:BMAGY.PROC PP")
    field(LNK7, "BEND:BC1B:800:BLEM.PROC PP")
    field(LNK8, "BEND:BC1B:800:BMOD.PROC PP")
    field(LNK9, "BEND:BC1B:800:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC1B:800:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC1B:800:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC1B:800:BMAX")
  field(DOL2, "BEND:BC1B:800:BMAX")
  field(DOL3, "BEND:BC1B:800:BMAX")
  field(DOL4, "BEND:BC1B:800:BMIN")
  field(DOL5, "BEND:BC1B:800:BMIN")
  field(DOL6, "BEND:BC1B:800:BMIN")
  field(LNK1, "BEND:BC1B:800:BMAGX.HOPR")
  field(LNK2, "BEND:BC1B:800:BMAGY.HOPR")
  field(LNK3, "BEND:BC1B:800:BLEM.HOPR")
  field(LNK4, "BEND:BC1B:800:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC1B:800:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC1B:800:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:800:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC1B:800:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC1B:800:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC1B:800:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC1B:800:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:800:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:BC1B:400:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:800:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:BC1B:400:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC1B:800:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC1B:800:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:BC1B:400:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC1B:800:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC1B:800:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC1B:800:EDES NPP MS")
  field(INPB, "BEND:BC1B:800:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DIAG0:260:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DIAG0:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DIAG0:1:CTRL.RVAL")
  field(LNK1, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL2, "MGNT:DIAG0:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL3, "MGNT:DIAG0:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL4, "MGNT:DIAG0:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL5, "MGNT:DIAG0:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL6, "MGNT:DIAG0:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL7, "MGNT:DIAG0:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL8, "MGNT:DIAG0:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DIAG0:260:FUNC CA PP")
  field(DOL9, "MGNT:DIAG0:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DIAG0:260:FUNC CA PP")
  field(DOLA, "MGNT:DIAG0:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DIAG0:260:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DIAG0:260:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DIAG0:260:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DIAG0:260:EDES.PROC PP")
    field(LNK2, "BEND:DIAG0:260:EACT.PROC PP")
    field(LNK3, "BEND:DIAG0:260:EERR.DISA PP")
    field(LNK4, "BEND:DIAG0:260:ECON.PROC PP")
    field(LNK5, "BEND:DIAG0:260:BMAGX.PROC PP")
    field(LNK6, "BEND:DIAG0:260:BMAGY.PROC PP")
    field(LNK7, "BEND:DIAG0:260:BLEM.PROC PP")
    field(LNK8, "BEND:DIAG0:260:BMOD.PROC PP")
    field(LNK9, "BEND:DIAG0:260:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DIAG0:260:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DIAG0:260:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DIAG0:260:BMAX")
  field(DOL2, "BEND:DIAG0:260:BMAX")
  field(DOL3, "BEND:DIAG0:260:BMAX")
  field(DOL4, "BEND:DIAG0:260:BMIN")
  field(DOL5, "BEND:DIAG0:260:BMIN")
  field(DOL6, "BEND:DIAG0:260:BMIN")
  field(LNK1, "BEND:DIAG0:260:BMAGX.HOPR")
  field(LNK2, "BEND:DIAG0:260:BMAGY.HOPR")
  field(LNK3, "BEND:DIAG0:260:BLEM.HOPR")
  field(LNK4, "BEND:DIAG0:260:BMAGX.LOPR PP")
  field(LNK5, "BEND:DIAG0:260:BMAGY.LOPR PP")
  field(LNK6, "BEND:DIAG0:260:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DIAG0:260:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DIAG0:260:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DIAG0:260:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DIAG0:260:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DIAG0:260:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:260:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DIAG0:155:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:260:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DIAG0:155:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DIAG0:260:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DIAG0:260:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DIAG0:155:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DIAG0:260:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DIAG0:260:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DIAG0:260:EDES NPP MS")
  field(INPB, "BEND:DIAG0:260:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC2B:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC2B:200:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC2B:200:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC2B:200:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC2B:200:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC2B:200:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC2B:200:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC2B:200:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC2B:200:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC2B:200:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC2B:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC2B:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC2B:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC2B:200:EDES.PROC PP")
    field(LNK2, "BEND:BC2B:200:EACT.PROC PP")
    field(LNK3, "BEND:BC2B:200:EERR.DISA PP")
    field(LNK4, "BEND:BC2B:200:ECON.PROC PP")
    field(LNK5, "BEND:BC2B:200:BMAGX.PROC PP")
    field(LNK6, "BEND:BC2B:200:BMAGY.PROC PP")
    field(LNK7, "BEND:BC2B:200:BLEM.PROC PP")
    field(LNK8, "BEND:BC2B:200:BMOD.PROC PP")
    field(LNK9, "BEND:BC2B:200:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC2B:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC2B:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC2B:200:BMAX")
  field(DOL2, "BEND:BC2B:200:BMAX")
  field(DOL3, "BEND:BC2B:200:BMAX")
  field(DOL4, "BEND:BC2B:200:BMIN")
  field(DOL5, "BEND:BC2B:200:BMIN")
  field(DOL6, "BEND:BC2B:200:BMIN")
  field(LNK1, "BEND:BC2B:200:BMAGX.HOPR")
  field(LNK2, "BEND:BC2B:200:BMAGY.HOPR")
  field(LNK3, "BEND:BC2B:200:BLEM.HOPR")
  field(LNK4, "BEND:BC2B:200:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC2B:200:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC2B:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC2B:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC2B:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC2B:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:BC2B:500:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:BC2B:500:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC2B:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:BC2B:500:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC2B:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC2B:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC2B:200:EDES NPP MS")
  field(INPB, "BEND:BC2B:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC2B:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC2B:600:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC2B:600:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC2B:600:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC2B:600:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC2B:600:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC2B:600:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC2B:600:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC2B:600:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC2B:600:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC2B:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC2B:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC2B:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC2B:600:EDES.PROC PP")
    field(LNK2, "BEND:BC2B:600:EACT.PROC PP")
    field(LNK3, "BEND:BC2B:600:EERR.DISA PP")
    field(LNK4, "BEND:BC2B:600:ECON.PROC PP")
    field(LNK5, "BEND:BC2B:600:BMAGX.PROC PP")
    field(LNK6, "BEND:BC2B:600:BMAGY.PROC PP")
    field(LNK7, "BEND:BC2B:600:BLEM.PROC PP")
    field(LNK8, "BEND:BC2B:600:BMOD.PROC PP")
    field(LNK9, "BEND:BC2B:600:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC2B:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC2B:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC2B:600:BMAX")
  field(DOL2, "BEND:BC2B:600:BMAX")
  field(DOL3, "BEND:BC2B:600:BMAX")
  field(DOL4, "BEND:BC2B:600:BMIN")
  field(DOL5, "BEND:BC2B:600:BMIN")
  field(DOL6, "BEND:BC2B:600:BMIN")
  field(LNK1, "BEND:BC2B:600:BMAGX.HOPR")
  field(LNK2, "BEND:BC2B:600:BMAGY.HOPR")
  field(LNK3, "BEND:BC2B:600:BLEM.HOPR")
  field(LNK4, "BEND:BC2B:600:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC2B:600:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC2B:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC2B:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC2B:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC2B:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:BC2B:500:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:BC2B:500:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC2B:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:BC2B:500:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC2B:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC2B:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC2B:600:EDES NPP MS")
  field(INPB, "BEND:BC2B:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BC2B:900:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:BC2B:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:BC2B:1:CTRL.RVAL")
  field(LNK1, "BEND:BC2B:900:FUNC CA PP")
  field(DOL2, "MGNT:BC2B:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BC2B:900:FUNC CA PP")
  field(DOL3, "MGNT:BC2B:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BC2B:900:FUNC CA PP")
  field(DOL4, "MGNT:BC2B:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BC2B:900:FUNC CA PP")
  field(DOL5, "MGNT:BC2B:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BC2B:900:FUNC CA PP")
  field(DOL6, "MGNT:BC2B:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BC2B:900:FUNC CA PP")
  field(DOL7, "MGNT:BC2B:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BC2B:900:FUNC CA PP")
  field(DOL8, "MGNT:BC2B:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BC2B:900:FUNC CA PP")
  field(DOL9, "MGNT:BC2B:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BC2B:900:FUNC CA PP")
  field(DOLA, "MGNT:BC2B:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BC2B:900:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BC2B:900:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BC2B:900:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BC2B:900:EDES.PROC PP")
    field(LNK2, "BEND:BC2B:900:EACT.PROC PP")
    field(LNK3, "BEND:BC2B:900:EERR.DISA PP")
    field(LNK4, "BEND:BC2B:900:ECON.PROC PP")
    field(LNK5, "BEND:BC2B:900:BMAGX.PROC PP")
    field(LNK6, "BEND:BC2B:900:BMAGY.PROC PP")
    field(LNK7, "BEND:BC2B:900:BLEM.PROC PP")
    field(LNK8, "BEND:BC2B:900:BMOD.PROC PP")
    field(LNK9, "BEND:BC2B:900:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BC2B:900:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BC2B:900:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BC2B:900:BMAX")
  field(DOL2, "BEND:BC2B:900:BMAX")
  field(DOL3, "BEND:BC2B:900:BMAX")
  field(DOL4, "BEND:BC2B:900:BMIN")
  field(DOL5, "BEND:BC2B:900:BMIN")
  field(DOL6, "BEND:BC2B:900:BMIN")
  field(LNK1, "BEND:BC2B:900:BMAGX.HOPR")
  field(LNK2, "BEND:BC2B:900:BMAGY.HOPR")
  field(LNK3, "BEND:BC2B:900:BLEM.HOPR")
  field(LNK4, "BEND:BC2B:900:BMAGX.LOPR PP")
  field(LNK5, "BEND:BC2B:900:BMAGY.LOPR PP")
  field(LNK6, "BEND:BC2B:900:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:900:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BC2B:900:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BC2B:900:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BC2B:900:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BC2B:900:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:900:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:BC2B:500:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:900:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:BC2B:500:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC2B:900:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BC2B:900:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:BC2B:500:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:BC2B:900:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BC2B:900:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BC2B:900:EDES NPP MS")
  field(INPB, "BEND:BC2B:900:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:105:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:105:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:105:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:105:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:105:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:105:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:105:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:105:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:105:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:105:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:105:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:105:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:105:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:105:EDES.PROC PP")
    field(LNK2, "BEND:DOG:105:EACT.PROC PP")
    field(LNK3, "BEND:DOG:105:EERR.DISA PP")
    field(LNK4, "BEND:DOG:105:ECON.PROC PP")
    field(LNK5, "BEND:DOG:105:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:105:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:105:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:105:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:105:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:105:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:105:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:105:BMAX")
  field(DOL2, "BEND:DOG:105:BMAX")
  field(DOL3, "BEND:DOG:105:BMAX")
  field(DOL4, "BEND:DOG:105:BMIN")
  field(DOL5, "BEND:DOG:105:BMIN")
  field(DOL6, "BEND:DOG:105:BMIN")
  field(LNK1, "BEND:DOG:105:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:105:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:105:BLEM.HOPR")
  field(LNK4, "BEND:DOG:105:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:105:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:105:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:105:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:105:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:105:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:105:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:105:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:105:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:106:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:105:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:106:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:105:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:105:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:106:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:105:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:105:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:105:EDES NPP MS")
  field(INPB, "BEND:DOG:105:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:107:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:107:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:107:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:107:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:107:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:107:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:107:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:107:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:107:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:107:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:107:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:107:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:107:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:107:EDES.PROC PP")
    field(LNK2, "BEND:DOG:107:EACT.PROC PP")
    field(LNK3, "BEND:DOG:107:EERR.DISA PP")
    field(LNK4, "BEND:DOG:107:ECON.PROC PP")
    field(LNK5, "BEND:DOG:107:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:107:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:107:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:107:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:107:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:107:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:107:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:107:BMAX")
  field(DOL2, "BEND:DOG:107:BMAX")
  field(DOL3, "BEND:DOG:107:BMAX")
  field(DOL4, "BEND:DOG:107:BMIN")
  field(DOL5, "BEND:DOG:107:BMIN")
  field(DOL6, "BEND:DOG:107:BMIN")
  field(LNK1, "BEND:DOG:107:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:107:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:107:BLEM.HOPR")
  field(LNK4, "BEND:DOG:107:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:107:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:107:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:107:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:107:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:107:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:107:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:107:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:107:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:106:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:107:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:106:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:107:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:107:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:106:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:107:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:107:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:107:EDES NPP MS")
  field(INPB, "BEND:DOG:107:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:108:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:108:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:108:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:108:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:108:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:108:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:108:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:108:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:108:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:108:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:108:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:108:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:108:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:108:EDES.PROC PP")
    field(LNK2, "BEND:DOG:108:EACT.PROC PP")
    field(LNK3, "BEND:DOG:108:EERR.DISA PP")
    field(LNK4, "BEND:DOG:108:ECON.PROC PP")
    field(LNK5, "BEND:DOG:108:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:108:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:108:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:108:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:108:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:108:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:108:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:108:BMAX")
  field(DOL2, "BEND:DOG:108:BMAX")
  field(DOL3, "BEND:DOG:108:BMAX")
  field(DOL4, "BEND:DOG:108:BMIN")
  field(DOL5, "BEND:DOG:108:BMIN")
  field(DOL6, "BEND:DOG:108:BMIN")
  field(LNK1, "BEND:DOG:108:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:108:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:108:BLEM.HOPR")
  field(LNK4, "BEND:DOG:108:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:108:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:108:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:108:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:108:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:108:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:108:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:108:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:108:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:106:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:108:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:106:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:108:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:108:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:106:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:108:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:108:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:108:EDES NPP MS")
  field(INPB, "BEND:DOG:108:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:241:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:241:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:241:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:241:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:241:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:241:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:241:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:241:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:241:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:241:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:241:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:241:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:241:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:241:EDES.PROC PP")
    field(LNK2, "BEND:DOG:241:EACT.PROC PP")
    field(LNK3, "BEND:DOG:241:EERR.DISA PP")
    field(LNK4, "BEND:DOG:241:ECON.PROC PP")
    field(LNK5, "BEND:DOG:241:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:241:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:241:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:241:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:241:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:241:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:241:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:241:BMAX")
  field(DOL2, "BEND:DOG:241:BMAX")
  field(DOL3, "BEND:DOG:241:BMAX")
  field(DOL4, "BEND:DOG:241:BMIN")
  field(DOL5, "BEND:DOG:241:BMIN")
  field(DOL6, "BEND:DOG:241:BMIN")
  field(LNK1, "BEND:DOG:241:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:241:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:241:BLEM.HOPR")
  field(LNK4, "BEND:DOG:241:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:241:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:241:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:241:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:241:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:241:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:241:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:241:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:241:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:242:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:241:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:242:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:241:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:241:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:242:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:241:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:241:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:241:EDES NPP MS")
  field(INPB, "BEND:DOG:241:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:243:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:243:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:243:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:243:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:243:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:243:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:243:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:243:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:243:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:243:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:243:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:243:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:243:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:243:EDES.PROC PP")
    field(LNK2, "BEND:DOG:243:EACT.PROC PP")
    field(LNK3, "BEND:DOG:243:EERR.DISA PP")
    field(LNK4, "BEND:DOG:243:ECON.PROC PP")
    field(LNK5, "BEND:DOG:243:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:243:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:243:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:243:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:243:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:243:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:243:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:243:BMAX")
  field(DOL2, "BEND:DOG:243:BMAX")
  field(DOL3, "BEND:DOG:243:BMAX")
  field(DOL4, "BEND:DOG:243:BMIN")
  field(DOL5, "BEND:DOG:243:BMIN")
  field(DOL6, "BEND:DOG:243:BMIN")
  field(LNK1, "BEND:DOG:243:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:243:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:243:BLEM.HOPR")
  field(LNK4, "BEND:DOG:243:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:243:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:243:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:243:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:243:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:243:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:243:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:243:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:243:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:242:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:243:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:242:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:243:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:243:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:242:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:243:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:243:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:243:EDES NPP MS")
  field(INPB, "BEND:DOG:243:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:244:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:244:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:244:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:244:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:244:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:244:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:244:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:244:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:244:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:244:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:244:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:244:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:244:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:244:EDES.PROC PP")
    field(LNK2, "BEND:DOG:244:EACT.PROC PP")
    field(LNK3, "BEND:DOG:244:EERR.DISA PP")
    field(LNK4, "BEND:DOG:244:ECON.PROC PP")
    field(LNK5, "BEND:DOG:244:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:244:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:244:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:244:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:244:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:244:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:244:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:244:BMAX")
  field(DOL2, "BEND:DOG:244:BMAX")
  field(DOL3, "BEND:DOG:244:BMAX")
  field(DOL4, "BEND:DOG:244:BMIN")
  field(DOL5, "BEND:DOG:244:BMIN")
  field(DOL6, "BEND:DOG:244:BMIN")
  field(LNK1, "BEND:DOG:244:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:244:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:244:BLEM.HOPR")
  field(LNK4, "BEND:DOG:244:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:244:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:244:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:244:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:244:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:244:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:244:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:244:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:244:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:242:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:244:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:242:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:244:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:244:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:242:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:244:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:244:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:244:EDES NPP MS")
  field(INPB, "BEND:DOG:244:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DOG:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "BEND:DOG:110:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DOG:110:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DOG:110:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DOG:110:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DOG:110:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DOG:110:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DOG:110:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DOG:110:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DOG:110:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DOG:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DOG:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DOG:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DOG:110:EDES.PROC PP")
    field(LNK2, "BEND:DOG:110:EACT.PROC PP")
    field(LNK3, "BEND:DOG:110:EERR.DISA PP")
    field(LNK4, "BEND:DOG:110:ECON.PROC PP")
    field(LNK5, "BEND:DOG:110:BMAGX.PROC PP")
    field(LNK6, "BEND:DOG:110:BMAGY.PROC PP")
    field(LNK7, "BEND:DOG:110:BLEM.PROC PP")
    field(LNK8, "BEND:DOG:110:BMOD.PROC PP")
    field(LNK9, "BEND:DOG:110:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DOG:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DOG:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DOG:110:BMAX")
  field(DOL2, "BEND:DOG:110:BMAX")
  field(DOL3, "BEND:DOG:110:BMAX")
  field(DOL4, "BEND:DOG:110:BMIN")
  field(DOL5, "BEND:DOG:110:BMIN")
  field(DOL6, "BEND:DOG:110:BMIN")
  field(LNK1, "BEND:DOG:110:BMAGX.HOPR")
  field(LNK2, "BEND:DOG:110:BMAGY.HOPR")
  field(LNK3, "BEND:DOG:110:BLEM.HOPR")
  field(LNK4, "BEND:DOG:110:BMAGX.LOPR PP")
  field(LNK5, "BEND:DOG:110:BMAGY.LOPR PP")
  field(LNK6, "BEND:DOG:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DOG:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DOG:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DOG:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DOG:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:DOG:240:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:240:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DOG:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:DOG:240:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:DOG:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DOG:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DOG:110:EDES NPP MS")
  field(INPB, "BEND:DOG:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:180:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:180:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:180:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:180:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:180:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:180:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:180:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:180:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:180:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:180:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:180:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:180:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:180:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:180:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:180:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:180:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:180:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:180:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:180:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:180:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:180:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:180:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:180:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:180:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:180:BMAX")
  field(DOL2, "QUAD:DOG:180:BMAX")
  field(DOL3, "QUAD:DOG:180:BMAX")
  field(DOL4, "QUAD:DOG:180:BMIN")
  field(DOL5, "QUAD:DOG:180:BMIN")
  field(DOL6, "QUAD:DOG:180:BMIN")
  field(LNK1, "QUAD:DOG:180:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:180:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:180:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:180:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:180:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:180:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:180:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:180:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:180:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:180:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:180:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:180:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:120:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:180:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:120:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:180:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:180:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:120:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:180:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:180:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:180:EDES NPP MS")
  field(INPB, "QUAD:DOG:180:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:200:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:200:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:200:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:200:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:200:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:200:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:200:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:200:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:200:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:200:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:200:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:200:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:200:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:200:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:200:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:200:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:200:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:200:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:200:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:200:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:200:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:200:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:200:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:200:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:200:BMAX")
  field(DOL2, "QUAD:DOG:200:BMAX")
  field(DOL3, "QUAD:DOG:200:BMAX")
  field(DOL4, "QUAD:DOG:200:BMIN")
  field(DOL5, "QUAD:DOG:200:BMIN")
  field(DOL6, "QUAD:DOG:200:BMIN")
  field(LNK1, "QUAD:DOG:200:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:200:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:200:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:200:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:200:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:200:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:200:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:200:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:200:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:200:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:200:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:200:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:135:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:200:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:135:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:200:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:200:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:135:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:200:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:200:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:200:EDES NPP MS")
  field(INPB, "QUAD:DOG:200:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:215:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:215:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:215:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:215:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:215:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:215:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:215:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:215:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:215:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:215:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:215:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:215:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:215:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:215:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:215:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:215:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:215:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:215:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:215:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:215:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:215:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:215:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:215:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:215:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:215:BMAX")
  field(DOL2, "QUAD:DOG:215:BMAX")
  field(DOL3, "QUAD:DOG:215:BMAX")
  field(DOL4, "QUAD:DOG:215:BMIN")
  field(DOL5, "QUAD:DOG:215:BMIN")
  field(DOL6, "QUAD:DOG:215:BMIN")
  field(LNK1, "QUAD:DOG:215:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:215:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:215:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:215:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:215:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:215:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:215:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:215:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:215:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:215:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:215:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:215:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:150:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:215:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:150:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:215:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:215:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:150:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:215:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:215:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:215:EDES NPP MS")
  field(INPB, "QUAD:DOG:215:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:230:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:230:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:230:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:230:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:230:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:230:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:230:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:230:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:230:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:230:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:230:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:230:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:230:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:230:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:230:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:230:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:230:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:230:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:230:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:230:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:230:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:230:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:230:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:230:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:230:BMAX")
  field(DOL2, "QUAD:DOG:230:BMAX")
  field(DOL3, "QUAD:DOG:230:BMAX")
  field(DOL4, "QUAD:DOG:230:BMIN")
  field(DOL5, "QUAD:DOG:230:BMIN")
  field(DOL6, "QUAD:DOG:230:BMIN")
  field(LNK1, "QUAD:DOG:230:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:230:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:230:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:230:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:230:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:230:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:230:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:230:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:230:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:230:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:230:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:230:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:165:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:230:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:165:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:230:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:230:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:165:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:230:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:230:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:230:EDES NPP MS")
  field(INPB, "QUAD:DOG:230:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:740:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:740:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:740:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:740:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:740:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:740:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:740:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:740:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:740:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:740:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:740:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:740:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:740:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:740:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:740:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:740:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:740:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:740:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:740:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:740:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:740:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:740:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:740:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:740:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:740:BMAX")
  field(DOL2, "QUAD:DOG:740:BMAX")
  field(DOL3, "QUAD:DOG:740:BMAX")
  field(DOL4, "QUAD:DOG:740:BMIN")
  field(DOL5, "QUAD:DOG:740:BMIN")
  field(DOL6, "QUAD:DOG:740:BMIN")
  field(LNK1, "QUAD:DOG:740:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:740:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:740:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:740:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:740:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:740:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:740:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:740:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:740:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:740:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:740:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:740:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:740:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:740:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:740:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:740:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:740:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:740:EDES NPP MS")
  field(INPB, "QUAD:DOG:740:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DOG:910:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:DOG:910:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DOG:910:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DOG:910:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DOG:910:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DOG:910:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DOG:910:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DOG:910:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DOG:910:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DOG:910:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DOG:910:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DOG:910:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DOG:910:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DOG:910:EDES.PROC PP")
    field(LNK2, "QUAD:DOG:910:EACT.PROC PP")
    field(LNK3, "QUAD:DOG:910:EERR.DISA PP")
    field(LNK4, "QUAD:DOG:910:ECON.PROC PP")
    field(LNK5, "QUAD:DOG:910:BMAGX.PROC PP")
    field(LNK6, "QUAD:DOG:910:BMAGY.PROC PP")
    field(LNK7, "QUAD:DOG:910:BLEM.PROC PP")
    field(LNK8, "QUAD:DOG:910:BMOD.PROC PP")
    field(LNK9, "QUAD:DOG:910:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DOG:910:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DOG:910:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DOG:910:BMAX")
  field(DOL2, "QUAD:DOG:910:BMAX")
  field(DOL3, "QUAD:DOG:910:BMAX")
  field(DOL4, "QUAD:DOG:910:BMIN")
  field(DOL5, "QUAD:DOG:910:BMIN")
  field(DOL6, "QUAD:DOG:910:BMIN")
  field(LNK1, "QUAD:DOG:910:BMAGX.HOPR")
  field(LNK2, "QUAD:DOG:910:BMAGY.HOPR")
  field(LNK3, "QUAD:DOG:910:BLEM.HOPR")
  field(LNK4, "QUAD:DOG:910:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DOG:910:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DOG:910:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:910:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DOG:910:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DOG:910:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DOG:910:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DOG:910:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:910:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:910:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:910:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DOG:910:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DOG:910:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DOG:910:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DOG:910:EDES NPP MS")
  field(INPB, "QUAD:DOG:910:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN13:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN13:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN13:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN13:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN13:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN13:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN13:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN13:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN13:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN13:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN13:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN13:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN13:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN13:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN13:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN13:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN13:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN13:400:BMAX")
  field(DOL2, "QUAD:BPN13:400:BMAX")
  field(DOL3, "QUAD:BPN13:400:BMAX")
  field(DOL4, "QUAD:BPN13:400:BMIN")
  field(DOL5, "QUAD:BPN13:400:BMIN")
  field(DOL6, "QUAD:BPN13:400:BMIN")
  field(LNK1, "QUAD:BPN13:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN13:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN13:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN13:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN13:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN13:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN13:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN13:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN13:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN13:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN13:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN13:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN13:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN13:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN13:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN13:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN13:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN13:400:EDES NPP MS")
  field(INPB, "QUAD:BPN13:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN14:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN14:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN14:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN14:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN14:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN14:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN14:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN14:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN14:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN14:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN14:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN14:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN14:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN14:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN14:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN14:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN14:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN14:400:BMAX")
  field(DOL2, "QUAD:BPN14:400:BMAX")
  field(DOL3, "QUAD:BPN14:400:BMAX")
  field(DOL4, "QUAD:BPN14:400:BMIN")
  field(DOL5, "QUAD:BPN14:400:BMIN")
  field(DOL6, "QUAD:BPN14:400:BMIN")
  field(LNK1, "QUAD:BPN14:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN14:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN14:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN14:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN14:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN14:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN14:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN14:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN14:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN14:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN14:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN14:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN14:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN14:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN14:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN14:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN14:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN14:400:EDES NPP MS")
  field(INPB, "QUAD:BPN14:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN15:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN15:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN15:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN15:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN15:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN15:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN15:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN15:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN15:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN15:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN15:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN15:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN15:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN15:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN15:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN15:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN15:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN15:400:BMAX")
  field(DOL2, "QUAD:BPN15:400:BMAX")
  field(DOL3, "QUAD:BPN15:400:BMAX")
  field(DOL4, "QUAD:BPN15:400:BMIN")
  field(DOL5, "QUAD:BPN15:400:BMIN")
  field(DOL6, "QUAD:BPN15:400:BMIN")
  field(LNK1, "QUAD:BPN15:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN15:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN15:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN15:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN15:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN15:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN15:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN15:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN15:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN15:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN15:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN15:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN15:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN15:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN15:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN15:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN15:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN15:400:EDES NPP MS")
  field(INPB, "QUAD:BPN15:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN16:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN16:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN16:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN16:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN16:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN16:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN16:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN16:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN16:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN16:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN16:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN16:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN16:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN16:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN16:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN16:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN16:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN16:400:BMAX")
  field(DOL2, "QUAD:BPN16:400:BMAX")
  field(DOL3, "QUAD:BPN16:400:BMAX")
  field(DOL4, "QUAD:BPN16:400:BMIN")
  field(DOL5, "QUAD:BPN16:400:BMIN")
  field(DOL6, "QUAD:BPN16:400:BMIN")
  field(LNK1, "QUAD:BPN16:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN16:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN16:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN16:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN16:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN16:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN16:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN16:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN16:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN16:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN16:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN16:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN16:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN16:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN16:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN16:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN16:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN16:400:EDES NPP MS")
  field(INPB, "QUAD:BPN16:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN17:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN17:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN17:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN17:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN17:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN17:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN17:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN17:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN17:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN17:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN17:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN17:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN17:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN17:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN17:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN17:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN17:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN17:400:BMAX")
  field(DOL2, "QUAD:BPN17:400:BMAX")
  field(DOL3, "QUAD:BPN17:400:BMAX")
  field(DOL4, "QUAD:BPN17:400:BMIN")
  field(DOL5, "QUAD:BPN17:400:BMIN")
  field(DOL6, "QUAD:BPN17:400:BMIN")
  field(LNK1, "QUAD:BPN17:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN17:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN17:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN17:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN17:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN17:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN17:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN17:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN17:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN17:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN17:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN17:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN17:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN17:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN17:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN17:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN17:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN17:400:EDES NPP MS")
  field(INPB, "QUAD:BPN17:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN18:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN18:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN18:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN18:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN18:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN18:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN18:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN18:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN18:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN18:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN18:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN18:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN18:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN18:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN18:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN18:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN18:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN18:400:BMAX")
  field(DOL2, "QUAD:BPN18:400:BMAX")
  field(DOL3, "QUAD:BPN18:400:BMAX")
  field(DOL4, "QUAD:BPN18:400:BMIN")
  field(DOL5, "QUAD:BPN18:400:BMIN")
  field(DOL6, "QUAD:BPN18:400:BMIN")
  field(LNK1, "QUAD:BPN18:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN18:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN18:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN18:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN18:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN18:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN18:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN18:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN18:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN18:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN18:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN18:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN18:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN18:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN18:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN18:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN18:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN18:400:EDES NPP MS")
  field(INPB, "QUAD:BPN18:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN19:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN19:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN19:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN19:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN19:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN19:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN19:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN19:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN19:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN19:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN19:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN19:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN19:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN19:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN19:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN19:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN19:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN19:400:BMAX")
  field(DOL2, "QUAD:BPN19:400:BMAX")
  field(DOL3, "QUAD:BPN19:400:BMAX")
  field(DOL4, "QUAD:BPN19:400:BMIN")
  field(DOL5, "QUAD:BPN19:400:BMIN")
  field(DOL6, "QUAD:BPN19:400:BMIN")
  field(LNK1, "QUAD:BPN19:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN19:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN19:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN19:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN19:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN19:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN19:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN19:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN19:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN19:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN19:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN19:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN19:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN19:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN19:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN19:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN19:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN19:400:EDES NPP MS")
  field(INPB, "QUAD:BPN19:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN20:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN20:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN20:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN20:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN20:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN20:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN20:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN20:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN20:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN20:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN20:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN20:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN20:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN20:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN20:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN20:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN20:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN20:400:BMAX")
  field(DOL2, "QUAD:BPN20:400:BMAX")
  field(DOL3, "QUAD:BPN20:400:BMAX")
  field(DOL4, "QUAD:BPN20:400:BMIN")
  field(DOL5, "QUAD:BPN20:400:BMIN")
  field(DOL6, "QUAD:BPN20:400:BMIN")
  field(LNK1, "QUAD:BPN20:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN20:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN20:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN20:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN20:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN20:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN20:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN20:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN20:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN20:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN20:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN20:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN20:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN20:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN20:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN20:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN20:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN20:400:EDES NPP MS")
  field(INPB, "QUAD:BPN20:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN21:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN21:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN21:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN21:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN21:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN21:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN21:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN21:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN21:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN21:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN21:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN21:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN21:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN21:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN21:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN21:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN21:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN21:400:BMAX")
  field(DOL2, "QUAD:BPN21:400:BMAX")
  field(DOL3, "QUAD:BPN21:400:BMAX")
  field(DOL4, "QUAD:BPN21:400:BMIN")
  field(DOL5, "QUAD:BPN21:400:BMIN")
  field(DOL6, "QUAD:BPN21:400:BMIN")
  field(LNK1, "QUAD:BPN21:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN21:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN21:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN21:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN21:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN21:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN21:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN21:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN21:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN21:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN21:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN21:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN21:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN21:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN21:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN21:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN21:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN21:400:EDES NPP MS")
  field(INPB, "QUAD:BPN21:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN22:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN22:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN22:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN22:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN22:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN22:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN22:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN22:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN22:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN22:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN22:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN22:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN22:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN22:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN22:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN22:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN22:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN22:400:BMAX")
  field(DOL2, "QUAD:BPN22:400:BMAX")
  field(DOL3, "QUAD:BPN22:400:BMAX")
  field(DOL4, "QUAD:BPN22:400:BMIN")
  field(DOL5, "QUAD:BPN22:400:BMIN")
  field(DOL6, "QUAD:BPN22:400:BMIN")
  field(LNK1, "QUAD:BPN22:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN22:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN22:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN22:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN22:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN22:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN22:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN22:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN22:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN22:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN22:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN22:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN22:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN22:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN22:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN22:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN22:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN22:400:EDES NPP MS")
  field(INPB, "QUAD:BPN22:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN23:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN23:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN23:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN23:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN23:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN23:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN23:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN23:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN23:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN23:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN23:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN23:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN23:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN23:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN23:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN23:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN23:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN23:400:BMAX")
  field(DOL2, "QUAD:BPN23:400:BMAX")
  field(DOL3, "QUAD:BPN23:400:BMAX")
  field(DOL4, "QUAD:BPN23:400:BMIN")
  field(DOL5, "QUAD:BPN23:400:BMIN")
  field(DOL6, "QUAD:BPN23:400:BMIN")
  field(LNK1, "QUAD:BPN23:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN23:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN23:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN23:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN23:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN23:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN23:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN23:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN23:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN23:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN23:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN23:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN23:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN23:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN23:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN23:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN23:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN23:400:EDES NPP MS")
  field(INPB, "QUAD:BPN23:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:BPN24:400:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DOG:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DOG:1:CTRL.RVAL")
  field(LNK1, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL2, "MGNT:DOG:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL3, "MGNT:DOG:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL4, "MGNT:DOG:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL5, "MGNT:DOG:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL6, "MGNT:DOG:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL7, "MGNT:DOG:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL8, "MGNT:DOG:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:BPN24:400:FUNC CA PP")
  field(DOL9, "MGNT:DOG:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:BPN24:400:FUNC CA PP")
  field(DOLA, "MGNT:DOG:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:BPN24:400:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:BPN24:400:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:BPN24:400:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:BPN24:400:EDES.PROC PP")
    field(LNK2, "QUAD:BPN24:400:EACT.PROC PP")
    field(LNK3, "QUAD:BPN24:400:EERR.DISA PP")
    field(LNK4, "QUAD:BPN24:400:ECON.PROC PP")
    field(LNK5, "QUAD:BPN24:400:BMAGX.PROC PP")
    field(LNK6, "QUAD:BPN24:400:BMAGY.PROC PP")
    field(LNK7, "QUAD:BPN24:400:BLEM.PROC PP")
    field(LNK8, "QUAD:BPN24:400:BMOD.PROC PP")
    field(LNK9, "QUAD:BPN24:400:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:BPN24:400:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:BPN24:400:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:BPN24:400:BMAX")
  field(DOL2, "QUAD:BPN24:400:BMAX")
  field(DOL3, "QUAD:BPN24:400:BMAX")
  field(DOL4, "QUAD:BPN24:400:BMIN")
  field(DOL5, "QUAD:BPN24:400:BMIN")
  field(DOL6, "QUAD:BPN24:400:BMIN")
  field(LNK1, "QUAD:BPN24:400:BMAGX.HOPR")
  field(LNK2, "QUAD:BPN24:400:BMAGY.HOPR")
  field(LNK3, "QUAD:BPN24:400:BLEM.HOPR")
  field(LNK4, "QUAD:BPN24:400:BMAGX.LOPR PP")
  field(LNK5, "QUAD:BPN24:400:BMAGY.LOPR PP")
  field(LNK6, "QUAD:BPN24:400:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN24:400:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:BPN24:400:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:BPN24:400:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:BPN24:400:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:BPN24:400:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN24:400:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DOG:575:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN24:400:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN24:400:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:BPN24:400:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DOG:575:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:BPN24:400:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:BPN24:400:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:BPN24:400:EDES NPP MS")
  field(INPB, "QUAD:BPN24:400:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:SPH:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:SPH:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:SPH:1:CTRL CA PP")
  field(LNK2, "MGNT:SPH:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:SPH:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:SPH:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:SPH:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:SPH:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:SPH:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:SPH:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:SPH:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:SPH:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:SPH:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:SPH:1:ALLSWITCH")
}

record(seq, "MGNT:SPH:1:ALLSWITCH") {
  field(DOL1, "MGNT:SPH:1:CTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:CTRL")
}

record(bo, "MGNT:SPH:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:SPH:1:ALLSTARGO")
}

record(fanout, "MGNT:SPH:1:ALLSTARGO") {
  field(LNK1, "MGNT:SPH:1:ALLBENDSGO")
  field(LNK2, "MGNT:SPH:1:ALLBTRMSGO")
  field(LNK3, "MGNT:SPH:1:ALLLGPSSGO")
  field(LNK4, "MGNT:SPH:1:ALLQUADSGO")
  field(LNK5, "MGNT:SPH:1:ALLXCORSGO")
  field(LNK6, "MGNT:SPH:1:ALLYCORSGO")
  field(FLNK, "MGNT:SPH:1:ALLSTARGO_2")
}
record(fanout, "MGNT:SPH:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:SPH:1:ALLSOLNSGO")
  field(LNK2, "MGNT:SPH:1:ALLKICKSGO")
  field(LNK3, "MGNT:SPH:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:SPH:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:SPH:1:BENDSWITCH")
}

record(seq, "MGNT:SPH:1:BENDSWITCH") {
  field(DOL1, "MGNT:SPH:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:BENDCTRL")
}

record(seq, "MGNT:SPH:1:ALLBENDSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:BENDCTRL",20,10,0,0,"MGNT:SPH:1:BENDCTRL")
#! Field("MGNT:SPH:1:BENDCTRL.FLNK",16777215,1,"MGNT:SPH:1:BENDCTRL.FLNK")
#! Link("MGNT:SPH:1:BENDCTRL.FLNK","MGNT:SPH:1:BENDSWITCH")
#! Field("MGNT:SPH:1:BENDCTRL.FFVL",16777215,1,"MGNT:SPH:1:BENDCTRL.FFVL")
#! Record("MGNT:SPH:1:BENDSWITCH",460,322,0,0,"MGNT:SPH:1:BENDSWITCH")
#! Field("MGNT:SPH:1:BENDSWITCH.DOL1",16777215,0,"MGNT:SPH:1:BENDSWITCH.DOL1")
#! Link("MGNT:SPH:1:BENDSWITCH.DOL1","MGNT:SPH:1:BENDCTRL.FFVL")
#! Field("MGNT:SPH:1:BENDSWITCH.LNK1",16777215,1,"MGNT:SPH:1:BENDSWITCH.LNK1")
#! Field("MGNT:SPH:1:BENDSWITCH.FLNK",16777215,1,"MGNT:SPH:1:BENDSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLBENDSGO",240,96,0,0,"MGNT:SPH:1:ALLBENDSGO")
#! Field("MGNT:SPH:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLBENDSGO.DOL1")
#! Field("MGNT:SPH:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLBENDSGO.LNK1")
#! Link("MGNT:SPH:1:ALLBENDSGO.LNK1","MGNT:SPH:1:ALLBENDS.VAL")
#! Record("MGNT:SPH:1:ALLBENDS",540,102,0,0,"MGNT:SPH:1:ALLBENDS")
#! Field("MGNT:SPH:1:ALLBENDS.VAL",16777215,0,"MGNT:SPH:1:ALLBENDS.VAL")
#! Field("MGNT:SPH:1:ALLBENDS.FLNK",16777215,1,"MGNT:SPH:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:SPH:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SPH:1:BTRMSWITCH")
}

record(seq, "MGNT:SPH:1:BTRMSWITCH") {
  field(DOL1, "MGNT:SPH:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:BTRMCTRL")
}

record(seq, "MGNT:SPH:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:BTRMCTRL",20,10,0,0,"MGNT:SPH:1:BTRMCTRL")
#! Field("MGNT:SPH:1:BTRMCTRL.FLNK",16777215,1,"MGNT:SPH:1:BTRMCTRL.FLNK")
#! Link("MGNT:SPH:1:BTRMCTRL.FLNK","MGNT:SPH:1:BTRMSWITCH")
#! Field("MGNT:SPH:1:BTRMCTRL.FFVL",16777215,1,"MGNT:SPH:1:BTRMCTRL.FFVL")
#! Record("MGNT:SPH:1:BTRMSWITCH",460,322,0,0,"MGNT:SPH:1:BTRMSWITCH")
#! Field("MGNT:SPH:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:SPH:1:BTRMSWITCH.DOL1")
#! Link("MGNT:SPH:1:BTRMSWITCH.DOL1","MGNT:SPH:1:BTRMCTRL.FFVL")
#! Field("MGNT:SPH:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:SPH:1:BTRMSWITCH.LNK1")
#! Field("MGNT:SPH:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:SPH:1:BTRMSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLBTRMSGO",240,96,0,0,"MGNT:SPH:1:ALLBTRMSGO")
#! Field("MGNT:SPH:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:SPH:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:SPH:1:ALLBTRMSGO.LNK1","MGNT:SPH:1:ALLBTRMS.VAL")
#! Record("MGNT:SPH:1:ALLBTRMS",540,102,0,0,"MGNT:SPH:1:ALLBTRMS")
#! Field("MGNT:SPH:1:ALLBTRMS.VAL",16777215,0,"MGNT:SPH:1:ALLBTRMS.VAL")
#! Field("MGNT:SPH:1:ALLBTRMS.FLNK",16777215,1,"MGNT:SPH:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:SPH:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SPH:1:LGPSSWITCH")
}

record(seq, "MGNT:SPH:1:LGPSSWITCH") {
  field(DOL1, "MGNT:SPH:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:LGPSCTRL")
}

record(seq, "MGNT:SPH:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:LGPSCTRL",20,10,0,0,"MGNT:SPH:1:LGPSCTRL")
#! Field("MGNT:SPH:1:LGPSCTRL.FLNK",16777215,1,"MGNT:SPH:1:LGPSCTRL.FLNK")
#! Link("MGNT:SPH:1:LGPSCTRL.FLNK","MGNT:SPH:1:LGPSSWITCH")
#! Field("MGNT:SPH:1:LGPSCTRL.FFVL",16777215,1,"MGNT:SPH:1:LGPSCTRL.FFVL")
#! Record("MGNT:SPH:1:LGPSSWITCH",460,322,0,0,"MGNT:SPH:1:LGPSSWITCH")
#! Field("MGNT:SPH:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:SPH:1:LGPSSWITCH.DOL1")
#! Link("MGNT:SPH:1:LGPSSWITCH.DOL1","MGNT:SPH:1:LGPSCTRL.FFVL")
#! Field("MGNT:SPH:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:SPH:1:LGPSSWITCH.LNK1")
#! Field("MGNT:SPH:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:SPH:1:LGPSSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLLGPSSGO",240,96,0,0,"MGNT:SPH:1:ALLLGPSSGO")
#! Field("MGNT:SPH:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:SPH:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:SPH:1:ALLLGPSSGO.LNK1","MGNT:SPH:1:ALLLGPSS.VAL")
#! Record("MGNT:SPH:1:ALLLGPSS",540,102,0,0,"MGNT:SPH:1:ALLLGPSS")
#! Field("MGNT:SPH:1:ALLLGPSS.VAL",16777215,0,"MGNT:SPH:1:ALLLGPSS.VAL")
#! Field("MGNT:SPH:1:ALLLGPSS.FLNK",16777215,1,"MGNT:SPH:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:SPH:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:SPH:1:QUADSWITCH")
}

record(seq, "MGNT:SPH:1:QUADSWITCH") {
  field(DOL1, "MGNT:SPH:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:QUADCTRL")
}

record(seq, "MGNT:SPH:1:ALLQUADSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:QUADCTRL",20,10,0,0,"MGNT:SPH:1:QUADCTRL")
#! Field("MGNT:SPH:1:QUADCTRL.FLNK",16777215,1,"MGNT:SPH:1:QUADCTRL.FLNK")
#! Link("MGNT:SPH:1:QUADCTRL.FLNK","MGNT:SPH:1:QUADSWITCH")
#! Field("MGNT:SPH:1:QUADCTRL.FFVL",16777215,1,"MGNT:SPH:1:QUADCTRL.FFVL")
#! Record("MGNT:SPH:1:QUADSWITCH",460,322,0,0,"MGNT:SPH:1:QUADSWITCH")
#! Field("MGNT:SPH:1:QUADSWITCH.DOL1",16777215,0,"MGNT:SPH:1:QUADSWITCH.DOL1")
#! Link("MGNT:SPH:1:QUADSWITCH.DOL1","MGNT:SPH:1:QUADCTRL.FFVL")
#! Field("MGNT:SPH:1:QUADSWITCH.LNK1",16777215,1,"MGNT:SPH:1:QUADSWITCH.LNK1")
#! Field("MGNT:SPH:1:QUADSWITCH.FLNK",16777215,1,"MGNT:SPH:1:QUADSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLQUADSGO",240,96,0,0,"MGNT:SPH:1:ALLQUADSGO")
#! Field("MGNT:SPH:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLQUADSGO.DOL1")
#! Field("MGNT:SPH:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLQUADSGO.LNK1")
#! Link("MGNT:SPH:1:ALLQUADSGO.LNK1","MGNT:SPH:1:ALLQUADS.VAL")
#! Record("MGNT:SPH:1:ALLQUADS",540,102,0,0,"MGNT:SPH:1:ALLQUADS")
#! Field("MGNT:SPH:1:ALLQUADS.VAL",16777215,0,"MGNT:SPH:1:ALLQUADS.VAL")
#! Field("MGNT:SPH:1:ALLQUADS.FLNK",16777215,1,"MGNT:SPH:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:SPH:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:SPH:1:XCORSWITCH")
}

record(seq, "MGNT:SPH:1:XCORSWITCH") {
  field(DOL1, "MGNT:SPH:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:XCORCTRL")
}

record(seq, "MGNT:SPH:1:ALLXCORSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:XCORCTRL",20,10,0,0,"MGNT:SPH:1:XCORCTRL")
#! Field("MGNT:SPH:1:XCORCTRL.FLNK",16777215,1,"MGNT:SPH:1:XCORCTRL.FLNK")
#! Link("MGNT:SPH:1:XCORCTRL.FLNK","MGNT:SPH:1:XCORSWITCH")
#! Field("MGNT:SPH:1:XCORCTRL.FFVL",16777215,1,"MGNT:SPH:1:XCORCTRL.FFVL")
#! Record("MGNT:SPH:1:XCORSWITCH",460,322,0,0,"MGNT:SPH:1:XCORSWITCH")
#! Field("MGNT:SPH:1:XCORSWITCH.DOL1",16777215,0,"MGNT:SPH:1:XCORSWITCH.DOL1")
#! Link("MGNT:SPH:1:XCORSWITCH.DOL1","MGNT:SPH:1:XCORCTRL.FFVL")
#! Field("MGNT:SPH:1:XCORSWITCH.LNK1",16777215,1,"MGNT:SPH:1:XCORSWITCH.LNK1")
#! Field("MGNT:SPH:1:XCORSWITCH.FLNK",16777215,1,"MGNT:SPH:1:XCORSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLXCORSGO",240,96,0,0,"MGNT:SPH:1:ALLXCORSGO")
#! Field("MGNT:SPH:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLXCORSGO.DOL1")
#! Field("MGNT:SPH:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLXCORSGO.LNK1")
#! Link("MGNT:SPH:1:ALLXCORSGO.LNK1","MGNT:SPH:1:ALLXCORS.VAL")
#! Record("MGNT:SPH:1:ALLXCORS",540,102,0,0,"MGNT:SPH:1:ALLXCORS")
#! Field("MGNT:SPH:1:ALLXCORS.VAL",16777215,0,"MGNT:SPH:1:ALLXCORS.VAL")
#! Field("MGNT:SPH:1:ALLXCORS.FLNK",16777215,1,"MGNT:SPH:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:SPH:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:SPH:1:YCORSWITCH")
}

record(seq, "MGNT:SPH:1:YCORSWITCH") {
  field(DOL1, "MGNT:SPH:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:YCORCTRL")
}

record(seq, "MGNT:SPH:1:ALLYCORSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:YCORCTRL",20,10,0,0,"MGNT:SPH:1:YCORCTRL")
#! Field("MGNT:SPH:1:YCORCTRL.FLNK",16777215,1,"MGNT:SPH:1:YCORCTRL.FLNK")
#! Link("MGNT:SPH:1:YCORCTRL.FLNK","MGNT:SPH:1:YCORSWITCH")
#! Field("MGNT:SPH:1:YCORCTRL.FFVL",16777215,1,"MGNT:SPH:1:YCORCTRL.FFVL")
#! Record("MGNT:SPH:1:YCORSWITCH",460,322,0,0,"MGNT:SPH:1:YCORSWITCH")
#! Field("MGNT:SPH:1:YCORSWITCH.DOL1",16777215,0,"MGNT:SPH:1:YCORSWITCH.DOL1")
#! Link("MGNT:SPH:1:YCORSWITCH.DOL1","MGNT:SPH:1:YCORCTRL.FFVL")
#! Field("MGNT:SPH:1:YCORSWITCH.LNK1",16777215,1,"MGNT:SPH:1:YCORSWITCH.LNK1")
#! Field("MGNT:SPH:1:YCORSWITCH.FLNK",16777215,1,"MGNT:SPH:1:YCORSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLYCORSGO",240,96,0,0,"MGNT:SPH:1:ALLYCORSGO")
#! Field("MGNT:SPH:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLYCORSGO.DOL1")
#! Field("MGNT:SPH:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLYCORSGO.LNK1")
#! Link("MGNT:SPH:1:ALLYCORSGO.LNK1","MGNT:SPH:1:ALLYCORS.VAL")
#! Record("MGNT:SPH:1:ALLYCORS",540,102,0,0,"MGNT:SPH:1:ALLYCORS")
#! Field("MGNT:SPH:1:ALLYCORS.VAL",16777215,0,"MGNT:SPH:1:ALLYCORS.VAL")
#! Field("MGNT:SPH:1:ALLYCORS.FLNK",16777215,1,"MGNT:SPH:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:SPH:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:SPH:1:SOLNSWITCH")
}

record(seq, "MGNT:SPH:1:SOLNSWITCH") {
  field(DOL1, "MGNT:SPH:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:SOLNCTRL")
}

record(seq, "MGNT:SPH:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:SOLNCTRL",20,10,0,0,"MGNT:SPH:1:SOLNCTRL")
#! Field("MGNT:SPH:1:SOLNCTRL.FLNK",16777215,1,"MGNT:SPH:1:SOLNCTRL.FLNK")
#! Link("MGNT:SPH:1:SOLNCTRL.FLNK","MGNT:SPH:1:SOLNSWITCH")
#! Field("MGNT:SPH:1:SOLNCTRL.FFVL",16777215,1,"MGNT:SPH:1:SOLNCTRL.FFVL")
#! Record("MGNT:SPH:1:SOLNSWITCH",460,322,0,0,"MGNT:SPH:1:SOLNSWITCH")
#! Field("MGNT:SPH:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:SPH:1:SOLNSWITCH.DOL1")
#! Link("MGNT:SPH:1:SOLNSWITCH.DOL1","MGNT:SPH:1:SOLNCTRL.FFVL")
#! Field("MGNT:SPH:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:SPH:1:SOLNSWITCH.LNK1")
#! Field("MGNT:SPH:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:SPH:1:SOLNSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLSOLNSGO",240,96,0,0,"MGNT:SPH:1:ALLSOLNSGO")
#! Field("MGNT:SPH:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:SPH:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:SPH:1:ALLSOLNSGO.LNK1","MGNT:SPH:1:ALLSOLNS.VAL")
#! Record("MGNT:SPH:1:ALLSOLNS",540,102,0,0,"MGNT:SPH:1:ALLSOLNS")
#! Field("MGNT:SPH:1:ALLSOLNS.VAL",16777215,0,"MGNT:SPH:1:ALLSOLNS.VAL")
#! Field("MGNT:SPH:1:ALLSOLNS.FLNK",16777215,1,"MGNT:SPH:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:SPH:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:SPH:1:KICKSWITCH")
}

record(seq, "MGNT:SPH:1:KICKSWITCH") {
  field(DOL1, "MGNT:SPH:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:KICKCTRL")
}

record(seq, "MGNT:SPH:1:ALLKICKSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:KICKCTRL",20,10,0,0,"MGNT:SPH:1:KICKCTRL")
#! Field("MGNT:SPH:1:KICKCTRL.FLNK",16777215,1,"MGNT:SPH:1:KICKCTRL.FLNK")
#! Link("MGNT:SPH:1:KICKCTRL.FLNK","MGNT:SPH:1:KICKSWITCH")
#! Field("MGNT:SPH:1:KICKCTRL.FFVL",16777215,1,"MGNT:SPH:1:KICKCTRL.FFVL")
#! Record("MGNT:SPH:1:KICKSWITCH",460,322,0,0,"MGNT:SPH:1:KICKSWITCH")
#! Field("MGNT:SPH:1:KICKSWITCH.DOL1",16777215,0,"MGNT:SPH:1:KICKSWITCH.DOL1")
#! Link("MGNT:SPH:1:KICKSWITCH.DOL1","MGNT:SPH:1:KICKCTRL.FFVL")
#! Field("MGNT:SPH:1:KICKSWITCH.LNK1",16777215,1,"MGNT:SPH:1:KICKSWITCH.LNK1")
#! Field("MGNT:SPH:1:KICKSWITCH.FLNK",16777215,1,"MGNT:SPH:1:KICKSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLKICKSGO",240,96,0,0,"MGNT:SPH:1:ALLKICKSGO")
#! Field("MGNT:SPH:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLKICKSGO.DOL1")
#! Field("MGNT:SPH:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLKICKSGO.LNK1")
#! Link("MGNT:SPH:1:ALLKICKSGO.LNK1","MGNT:SPH:1:ALLKICKS.VAL")
#! Record("MGNT:SPH:1:ALLKICKS",540,102,0,0,"MGNT:SPH:1:ALLKICKS")
#! Field("MGNT:SPH:1:ALLKICKS.VAL",16777215,0,"MGNT:SPH:1:ALLKICKS.VAL")
#! Field("MGNT:SPH:1:ALLKICKS.FLNK",16777215,1,"MGNT:SPH:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:SPH:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:SPH:1:SEXTSWITCH")
}

record(seq, "MGNT:SPH:1:SEXTSWITCH") {
  field(DOL1, "MGNT:SPH:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:SPH:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPH:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPH:1:SEXTCTRL")
}

record(seq, "MGNT:SPH:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:SPH:1:ALLSTAR")
  field(LNK1, "MGNT:SPH:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:SPH:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPH:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPH:1:SEXTCTRL",20,10,0,0,"MGNT:SPH:1:SEXTCTRL")
#! Field("MGNT:SPH:1:SEXTCTRL.FLNK",16777215,1,"MGNT:SPH:1:SEXTCTRL.FLNK")
#! Link("MGNT:SPH:1:SEXTCTRL.FLNK","MGNT:SPH:1:SEXTSWITCH")
#! Field("MGNT:SPH:1:SEXTCTRL.FFVL",16777215,1,"MGNT:SPH:1:SEXTCTRL.FFVL")
#! Record("MGNT:SPH:1:SEXTSWITCH",460,322,0,0,"MGNT:SPH:1:SEXTSWITCH")
#! Field("MGNT:SPH:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:SPH:1:SEXTSWITCH.DOL1")
#! Link("MGNT:SPH:1:SEXTSWITCH.DOL1","MGNT:SPH:1:SEXTCTRL.FFVL")
#! Field("MGNT:SPH:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:SPH:1:SEXTSWITCH.LNK1")
#! Field("MGNT:SPH:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:SPH:1:SEXTSWITCH.FLNK")
#! Record("MGNT:SPH:1:ALLSEXTSGO",240,96,0,0,"MGNT:SPH:1:ALLSEXTSGO")
#! Field("MGNT:SPH:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:SPH:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:SPH:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:SPH:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:SPH:1:ALLSEXTSGO.LNK1","MGNT:SPH:1:ALLSEXTS.VAL")
#! Record("MGNT:SPH:1:ALLSEXTS",540,102,0,0,"MGNT:SPH:1:ALLSEXTS")
#! Field("MGNT:SPH:1:ALLSEXTS.VAL",16777215,0,"MGNT:SPH:1:ALLSEXTS.VAL")
#! Field("MGNT:SPH:1:ALLSEXTS.FLNK",16777215,1,"MGNT:SPH:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:SPS:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:SPS:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:SPS:1:CTRL CA PP")
  field(LNK2, "MGNT:SPS:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:SPS:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:SPS:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:SPS:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:SPS:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:SPS:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:SPS:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:SPS:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:SPS:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:SPS:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:SPS:1:ALLSWITCH")
}

record(seq, "MGNT:SPS:1:ALLSWITCH") {
  field(DOL1, "MGNT:SPS:1:CTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:CTRL")
}

record(bo, "MGNT:SPS:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:SPS:1:ALLSTARGO")
}

record(fanout, "MGNT:SPS:1:ALLSTARGO") {
  field(LNK1, "MGNT:SPS:1:ALLBENDSGO")
  field(LNK2, "MGNT:SPS:1:ALLBTRMSGO")
  field(LNK3, "MGNT:SPS:1:ALLLGPSSGO")
  field(LNK4, "MGNT:SPS:1:ALLQUADSGO")
  field(LNK5, "MGNT:SPS:1:ALLXCORSGO")
  field(LNK6, "MGNT:SPS:1:ALLYCORSGO")
  field(FLNK, "MGNT:SPS:1:ALLSTARGO_2")
}
record(fanout, "MGNT:SPS:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:SPS:1:ALLSOLNSGO")
  field(LNK2, "MGNT:SPS:1:ALLKICKSGO")
  field(LNK3, "MGNT:SPS:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:SPS:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:SPS:1:BENDSWITCH")
}

record(seq, "MGNT:SPS:1:BENDSWITCH") {
  field(DOL1, "MGNT:SPS:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:BENDCTRL")
}

record(seq, "MGNT:SPS:1:ALLBENDSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:BENDCTRL",20,10,0,0,"MGNT:SPS:1:BENDCTRL")
#! Field("MGNT:SPS:1:BENDCTRL.FLNK",16777215,1,"MGNT:SPS:1:BENDCTRL.FLNK")
#! Link("MGNT:SPS:1:BENDCTRL.FLNK","MGNT:SPS:1:BENDSWITCH")
#! Field("MGNT:SPS:1:BENDCTRL.FFVL",16777215,1,"MGNT:SPS:1:BENDCTRL.FFVL")
#! Record("MGNT:SPS:1:BENDSWITCH",460,322,0,0,"MGNT:SPS:1:BENDSWITCH")
#! Field("MGNT:SPS:1:BENDSWITCH.DOL1",16777215,0,"MGNT:SPS:1:BENDSWITCH.DOL1")
#! Link("MGNT:SPS:1:BENDSWITCH.DOL1","MGNT:SPS:1:BENDCTRL.FFVL")
#! Field("MGNT:SPS:1:BENDSWITCH.LNK1",16777215,1,"MGNT:SPS:1:BENDSWITCH.LNK1")
#! Field("MGNT:SPS:1:BENDSWITCH.FLNK",16777215,1,"MGNT:SPS:1:BENDSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLBENDSGO",240,96,0,0,"MGNT:SPS:1:ALLBENDSGO")
#! Field("MGNT:SPS:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLBENDSGO.DOL1")
#! Field("MGNT:SPS:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLBENDSGO.LNK1")
#! Link("MGNT:SPS:1:ALLBENDSGO.LNK1","MGNT:SPS:1:ALLBENDS.VAL")
#! Record("MGNT:SPS:1:ALLBENDS",540,102,0,0,"MGNT:SPS:1:ALLBENDS")
#! Field("MGNT:SPS:1:ALLBENDS.VAL",16777215,0,"MGNT:SPS:1:ALLBENDS.VAL")
#! Field("MGNT:SPS:1:ALLBENDS.FLNK",16777215,1,"MGNT:SPS:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:SPS:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SPS:1:BTRMSWITCH")
}

record(seq, "MGNT:SPS:1:BTRMSWITCH") {
  field(DOL1, "MGNT:SPS:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:BTRMCTRL")
}

record(seq, "MGNT:SPS:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:BTRMCTRL",20,10,0,0,"MGNT:SPS:1:BTRMCTRL")
#! Field("MGNT:SPS:1:BTRMCTRL.FLNK",16777215,1,"MGNT:SPS:1:BTRMCTRL.FLNK")
#! Link("MGNT:SPS:1:BTRMCTRL.FLNK","MGNT:SPS:1:BTRMSWITCH")
#! Field("MGNT:SPS:1:BTRMCTRL.FFVL",16777215,1,"MGNT:SPS:1:BTRMCTRL.FFVL")
#! Record("MGNT:SPS:1:BTRMSWITCH",460,322,0,0,"MGNT:SPS:1:BTRMSWITCH")
#! Field("MGNT:SPS:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:SPS:1:BTRMSWITCH.DOL1")
#! Link("MGNT:SPS:1:BTRMSWITCH.DOL1","MGNT:SPS:1:BTRMCTRL.FFVL")
#! Field("MGNT:SPS:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:SPS:1:BTRMSWITCH.LNK1")
#! Field("MGNT:SPS:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:SPS:1:BTRMSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLBTRMSGO",240,96,0,0,"MGNT:SPS:1:ALLBTRMSGO")
#! Field("MGNT:SPS:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:SPS:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:SPS:1:ALLBTRMSGO.LNK1","MGNT:SPS:1:ALLBTRMS.VAL")
#! Record("MGNT:SPS:1:ALLBTRMS",540,102,0,0,"MGNT:SPS:1:ALLBTRMS")
#! Field("MGNT:SPS:1:ALLBTRMS.VAL",16777215,0,"MGNT:SPS:1:ALLBTRMS.VAL")
#! Field("MGNT:SPS:1:ALLBTRMS.FLNK",16777215,1,"MGNT:SPS:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:SPS:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SPS:1:LGPSSWITCH")
}

record(seq, "MGNT:SPS:1:LGPSSWITCH") {
  field(DOL1, "MGNT:SPS:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:LGPSCTRL")
}

record(seq, "MGNT:SPS:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:LGPSCTRL",20,10,0,0,"MGNT:SPS:1:LGPSCTRL")
#! Field("MGNT:SPS:1:LGPSCTRL.FLNK",16777215,1,"MGNT:SPS:1:LGPSCTRL.FLNK")
#! Link("MGNT:SPS:1:LGPSCTRL.FLNK","MGNT:SPS:1:LGPSSWITCH")
#! Field("MGNT:SPS:1:LGPSCTRL.FFVL",16777215,1,"MGNT:SPS:1:LGPSCTRL.FFVL")
#! Record("MGNT:SPS:1:LGPSSWITCH",460,322,0,0,"MGNT:SPS:1:LGPSSWITCH")
#! Field("MGNT:SPS:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:SPS:1:LGPSSWITCH.DOL1")
#! Link("MGNT:SPS:1:LGPSSWITCH.DOL1","MGNT:SPS:1:LGPSCTRL.FFVL")
#! Field("MGNT:SPS:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:SPS:1:LGPSSWITCH.LNK1")
#! Field("MGNT:SPS:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:SPS:1:LGPSSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLLGPSSGO",240,96,0,0,"MGNT:SPS:1:ALLLGPSSGO")
#! Field("MGNT:SPS:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:SPS:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:SPS:1:ALLLGPSSGO.LNK1","MGNT:SPS:1:ALLLGPSS.VAL")
#! Record("MGNT:SPS:1:ALLLGPSS",540,102,0,0,"MGNT:SPS:1:ALLLGPSS")
#! Field("MGNT:SPS:1:ALLLGPSS.VAL",16777215,0,"MGNT:SPS:1:ALLLGPSS.VAL")
#! Field("MGNT:SPS:1:ALLLGPSS.FLNK",16777215,1,"MGNT:SPS:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:SPS:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:SPS:1:QUADSWITCH")
}

record(seq, "MGNT:SPS:1:QUADSWITCH") {
  field(DOL1, "MGNT:SPS:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:QUADCTRL")
}

record(seq, "MGNT:SPS:1:ALLQUADSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:QUADCTRL",20,10,0,0,"MGNT:SPS:1:QUADCTRL")
#! Field("MGNT:SPS:1:QUADCTRL.FLNK",16777215,1,"MGNT:SPS:1:QUADCTRL.FLNK")
#! Link("MGNT:SPS:1:QUADCTRL.FLNK","MGNT:SPS:1:QUADSWITCH")
#! Field("MGNT:SPS:1:QUADCTRL.FFVL",16777215,1,"MGNT:SPS:1:QUADCTRL.FFVL")
#! Record("MGNT:SPS:1:QUADSWITCH",460,322,0,0,"MGNT:SPS:1:QUADSWITCH")
#! Field("MGNT:SPS:1:QUADSWITCH.DOL1",16777215,0,"MGNT:SPS:1:QUADSWITCH.DOL1")
#! Link("MGNT:SPS:1:QUADSWITCH.DOL1","MGNT:SPS:1:QUADCTRL.FFVL")
#! Field("MGNT:SPS:1:QUADSWITCH.LNK1",16777215,1,"MGNT:SPS:1:QUADSWITCH.LNK1")
#! Field("MGNT:SPS:1:QUADSWITCH.FLNK",16777215,1,"MGNT:SPS:1:QUADSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLQUADSGO",240,96,0,0,"MGNT:SPS:1:ALLQUADSGO")
#! Field("MGNT:SPS:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLQUADSGO.DOL1")
#! Field("MGNT:SPS:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLQUADSGO.LNK1")
#! Link("MGNT:SPS:1:ALLQUADSGO.LNK1","MGNT:SPS:1:ALLQUADS.VAL")
#! Record("MGNT:SPS:1:ALLQUADS",540,102,0,0,"MGNT:SPS:1:ALLQUADS")
#! Field("MGNT:SPS:1:ALLQUADS.VAL",16777215,0,"MGNT:SPS:1:ALLQUADS.VAL")
#! Field("MGNT:SPS:1:ALLQUADS.FLNK",16777215,1,"MGNT:SPS:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:SPS:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:SPS:1:XCORSWITCH")
}

record(seq, "MGNT:SPS:1:XCORSWITCH") {
  field(DOL1, "MGNT:SPS:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:XCORCTRL")
}

record(seq, "MGNT:SPS:1:ALLXCORSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:XCORCTRL",20,10,0,0,"MGNT:SPS:1:XCORCTRL")
#! Field("MGNT:SPS:1:XCORCTRL.FLNK",16777215,1,"MGNT:SPS:1:XCORCTRL.FLNK")
#! Link("MGNT:SPS:1:XCORCTRL.FLNK","MGNT:SPS:1:XCORSWITCH")
#! Field("MGNT:SPS:1:XCORCTRL.FFVL",16777215,1,"MGNT:SPS:1:XCORCTRL.FFVL")
#! Record("MGNT:SPS:1:XCORSWITCH",460,322,0,0,"MGNT:SPS:1:XCORSWITCH")
#! Field("MGNT:SPS:1:XCORSWITCH.DOL1",16777215,0,"MGNT:SPS:1:XCORSWITCH.DOL1")
#! Link("MGNT:SPS:1:XCORSWITCH.DOL1","MGNT:SPS:1:XCORCTRL.FFVL")
#! Field("MGNT:SPS:1:XCORSWITCH.LNK1",16777215,1,"MGNT:SPS:1:XCORSWITCH.LNK1")
#! Field("MGNT:SPS:1:XCORSWITCH.FLNK",16777215,1,"MGNT:SPS:1:XCORSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLXCORSGO",240,96,0,0,"MGNT:SPS:1:ALLXCORSGO")
#! Field("MGNT:SPS:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLXCORSGO.DOL1")
#! Field("MGNT:SPS:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLXCORSGO.LNK1")
#! Link("MGNT:SPS:1:ALLXCORSGO.LNK1","MGNT:SPS:1:ALLXCORS.VAL")
#! Record("MGNT:SPS:1:ALLXCORS",540,102,0,0,"MGNT:SPS:1:ALLXCORS")
#! Field("MGNT:SPS:1:ALLXCORS.VAL",16777215,0,"MGNT:SPS:1:ALLXCORS.VAL")
#! Field("MGNT:SPS:1:ALLXCORS.FLNK",16777215,1,"MGNT:SPS:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:SPS:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:SPS:1:YCORSWITCH")
}

record(seq, "MGNT:SPS:1:YCORSWITCH") {
  field(DOL1, "MGNT:SPS:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:YCORCTRL")
}

record(seq, "MGNT:SPS:1:ALLYCORSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:YCORCTRL",20,10,0,0,"MGNT:SPS:1:YCORCTRL")
#! Field("MGNT:SPS:1:YCORCTRL.FLNK",16777215,1,"MGNT:SPS:1:YCORCTRL.FLNK")
#! Link("MGNT:SPS:1:YCORCTRL.FLNK","MGNT:SPS:1:YCORSWITCH")
#! Field("MGNT:SPS:1:YCORCTRL.FFVL",16777215,1,"MGNT:SPS:1:YCORCTRL.FFVL")
#! Record("MGNT:SPS:1:YCORSWITCH",460,322,0,0,"MGNT:SPS:1:YCORSWITCH")
#! Field("MGNT:SPS:1:YCORSWITCH.DOL1",16777215,0,"MGNT:SPS:1:YCORSWITCH.DOL1")
#! Link("MGNT:SPS:1:YCORSWITCH.DOL1","MGNT:SPS:1:YCORCTRL.FFVL")
#! Field("MGNT:SPS:1:YCORSWITCH.LNK1",16777215,1,"MGNT:SPS:1:YCORSWITCH.LNK1")
#! Field("MGNT:SPS:1:YCORSWITCH.FLNK",16777215,1,"MGNT:SPS:1:YCORSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLYCORSGO",240,96,0,0,"MGNT:SPS:1:ALLYCORSGO")
#! Field("MGNT:SPS:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLYCORSGO.DOL1")
#! Field("MGNT:SPS:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLYCORSGO.LNK1")
#! Link("MGNT:SPS:1:ALLYCORSGO.LNK1","MGNT:SPS:1:ALLYCORS.VAL")
#! Record("MGNT:SPS:1:ALLYCORS",540,102,0,0,"MGNT:SPS:1:ALLYCORS")
#! Field("MGNT:SPS:1:ALLYCORS.VAL",16777215,0,"MGNT:SPS:1:ALLYCORS.VAL")
#! Field("MGNT:SPS:1:ALLYCORS.FLNK",16777215,1,"MGNT:SPS:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:SPS:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:SPS:1:SOLNSWITCH")
}

record(seq, "MGNT:SPS:1:SOLNSWITCH") {
  field(DOL1, "MGNT:SPS:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:SOLNCTRL")
}

record(seq, "MGNT:SPS:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:SOLNCTRL",20,10,0,0,"MGNT:SPS:1:SOLNCTRL")
#! Field("MGNT:SPS:1:SOLNCTRL.FLNK",16777215,1,"MGNT:SPS:1:SOLNCTRL.FLNK")
#! Link("MGNT:SPS:1:SOLNCTRL.FLNK","MGNT:SPS:1:SOLNSWITCH")
#! Field("MGNT:SPS:1:SOLNCTRL.FFVL",16777215,1,"MGNT:SPS:1:SOLNCTRL.FFVL")
#! Record("MGNT:SPS:1:SOLNSWITCH",460,322,0,0,"MGNT:SPS:1:SOLNSWITCH")
#! Field("MGNT:SPS:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:SPS:1:SOLNSWITCH.DOL1")
#! Link("MGNT:SPS:1:SOLNSWITCH.DOL1","MGNT:SPS:1:SOLNCTRL.FFVL")
#! Field("MGNT:SPS:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:SPS:1:SOLNSWITCH.LNK1")
#! Field("MGNT:SPS:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:SPS:1:SOLNSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLSOLNSGO",240,96,0,0,"MGNT:SPS:1:ALLSOLNSGO")
#! Field("MGNT:SPS:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:SPS:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:SPS:1:ALLSOLNSGO.LNK1","MGNT:SPS:1:ALLSOLNS.VAL")
#! Record("MGNT:SPS:1:ALLSOLNS",540,102,0,0,"MGNT:SPS:1:ALLSOLNS")
#! Field("MGNT:SPS:1:ALLSOLNS.VAL",16777215,0,"MGNT:SPS:1:ALLSOLNS.VAL")
#! Field("MGNT:SPS:1:ALLSOLNS.FLNK",16777215,1,"MGNT:SPS:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:SPS:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:SPS:1:KICKSWITCH")
}

record(seq, "MGNT:SPS:1:KICKSWITCH") {
  field(DOL1, "MGNT:SPS:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:KICKCTRL")
}

record(seq, "MGNT:SPS:1:ALLKICKSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:KICKCTRL",20,10,0,0,"MGNT:SPS:1:KICKCTRL")
#! Field("MGNT:SPS:1:KICKCTRL.FLNK",16777215,1,"MGNT:SPS:1:KICKCTRL.FLNK")
#! Link("MGNT:SPS:1:KICKCTRL.FLNK","MGNT:SPS:1:KICKSWITCH")
#! Field("MGNT:SPS:1:KICKCTRL.FFVL",16777215,1,"MGNT:SPS:1:KICKCTRL.FFVL")
#! Record("MGNT:SPS:1:KICKSWITCH",460,322,0,0,"MGNT:SPS:1:KICKSWITCH")
#! Field("MGNT:SPS:1:KICKSWITCH.DOL1",16777215,0,"MGNT:SPS:1:KICKSWITCH.DOL1")
#! Link("MGNT:SPS:1:KICKSWITCH.DOL1","MGNT:SPS:1:KICKCTRL.FFVL")
#! Field("MGNT:SPS:1:KICKSWITCH.LNK1",16777215,1,"MGNT:SPS:1:KICKSWITCH.LNK1")
#! Field("MGNT:SPS:1:KICKSWITCH.FLNK",16777215,1,"MGNT:SPS:1:KICKSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLKICKSGO",240,96,0,0,"MGNT:SPS:1:ALLKICKSGO")
#! Field("MGNT:SPS:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLKICKSGO.DOL1")
#! Field("MGNT:SPS:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLKICKSGO.LNK1")
#! Link("MGNT:SPS:1:ALLKICKSGO.LNK1","MGNT:SPS:1:ALLKICKS.VAL")
#! Record("MGNT:SPS:1:ALLKICKS",540,102,0,0,"MGNT:SPS:1:ALLKICKS")
#! Field("MGNT:SPS:1:ALLKICKS.VAL",16777215,0,"MGNT:SPS:1:ALLKICKS.VAL")
#! Field("MGNT:SPS:1:ALLKICKS.FLNK",16777215,1,"MGNT:SPS:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:SPS:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:SPS:1:SEXTSWITCH")
}

record(seq, "MGNT:SPS:1:SEXTSWITCH") {
  field(DOL1, "MGNT:SPS:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:SPS:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPS:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPS:1:SEXTCTRL")
}

record(seq, "MGNT:SPS:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:SPS:1:ALLSTAR")
  field(LNK1, "MGNT:SPS:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:SPS:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPS:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPS:1:SEXTCTRL",20,10,0,0,"MGNT:SPS:1:SEXTCTRL")
#! Field("MGNT:SPS:1:SEXTCTRL.FLNK",16777215,1,"MGNT:SPS:1:SEXTCTRL.FLNK")
#! Link("MGNT:SPS:1:SEXTCTRL.FLNK","MGNT:SPS:1:SEXTSWITCH")
#! Field("MGNT:SPS:1:SEXTCTRL.FFVL",16777215,1,"MGNT:SPS:1:SEXTCTRL.FFVL")
#! Record("MGNT:SPS:1:SEXTSWITCH",460,322,0,0,"MGNT:SPS:1:SEXTSWITCH")
#! Field("MGNT:SPS:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:SPS:1:SEXTSWITCH.DOL1")
#! Link("MGNT:SPS:1:SEXTSWITCH.DOL1","MGNT:SPS:1:SEXTCTRL.FFVL")
#! Field("MGNT:SPS:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:SPS:1:SEXTSWITCH.LNK1")
#! Field("MGNT:SPS:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:SPS:1:SEXTSWITCH.FLNK")
#! Record("MGNT:SPS:1:ALLSEXTSGO",240,96,0,0,"MGNT:SPS:1:ALLSEXTSGO")
#! Field("MGNT:SPS:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:SPS:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:SPS:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:SPS:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:SPS:1:ALLSEXTSGO.LNK1","MGNT:SPS:1:ALLSEXTS.VAL")
#! Record("MGNT:SPS:1:ALLSEXTS",540,102,0,0,"MGNT:SPS:1:ALLSEXTS")
#! Field("MGNT:SPS:1:ALLSEXTS.VAL",16777215,0,"MGNT:SPS:1:ALLSEXTS.VAL")
#! Field("MGNT:SPS:1:ALLSEXTS.FLNK",16777215,1,"MGNT:SPS:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:SPD:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:SPD:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:SPD:1:CTRL CA PP")
  field(LNK2, "MGNT:SPD:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:SPD:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:SPD:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:SPD:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:SPD:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:SPD:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:SPD:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:SPD:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:SPD:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:SPD:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:SPD:1:ALLSWITCH")
}

record(seq, "MGNT:SPD:1:ALLSWITCH") {
  field(DOL1, "MGNT:SPD:1:CTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:CTRL")
}

record(bo, "MGNT:SPD:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:SPD:1:ALLSTARGO")
}

record(fanout, "MGNT:SPD:1:ALLSTARGO") {
  field(LNK1, "MGNT:SPD:1:ALLBENDSGO")
  field(LNK2, "MGNT:SPD:1:ALLBTRMSGO")
  field(LNK3, "MGNT:SPD:1:ALLLGPSSGO")
  field(LNK4, "MGNT:SPD:1:ALLQUADSGO")
  field(LNK5, "MGNT:SPD:1:ALLXCORSGO")
  field(LNK6, "MGNT:SPD:1:ALLYCORSGO")
  field(FLNK, "MGNT:SPD:1:ALLSTARGO_2")
}
record(fanout, "MGNT:SPD:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:SPD:1:ALLSOLNSGO")
  field(LNK2, "MGNT:SPD:1:ALLKICKSGO")
  field(LNK3, "MGNT:SPD:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:SPD:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:SPD:1:BENDSWITCH")
}

record(seq, "MGNT:SPD:1:BENDSWITCH") {
  field(DOL1, "MGNT:SPD:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:BENDCTRL")
}

record(seq, "MGNT:SPD:1:ALLBENDSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:BENDCTRL",20,10,0,0,"MGNT:SPD:1:BENDCTRL")
#! Field("MGNT:SPD:1:BENDCTRL.FLNK",16777215,1,"MGNT:SPD:1:BENDCTRL.FLNK")
#! Link("MGNT:SPD:1:BENDCTRL.FLNK","MGNT:SPD:1:BENDSWITCH")
#! Field("MGNT:SPD:1:BENDCTRL.FFVL",16777215,1,"MGNT:SPD:1:BENDCTRL.FFVL")
#! Record("MGNT:SPD:1:BENDSWITCH",460,322,0,0,"MGNT:SPD:1:BENDSWITCH")
#! Field("MGNT:SPD:1:BENDSWITCH.DOL1",16777215,0,"MGNT:SPD:1:BENDSWITCH.DOL1")
#! Link("MGNT:SPD:1:BENDSWITCH.DOL1","MGNT:SPD:1:BENDCTRL.FFVL")
#! Field("MGNT:SPD:1:BENDSWITCH.LNK1",16777215,1,"MGNT:SPD:1:BENDSWITCH.LNK1")
#! Field("MGNT:SPD:1:BENDSWITCH.FLNK",16777215,1,"MGNT:SPD:1:BENDSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLBENDSGO",240,96,0,0,"MGNT:SPD:1:ALLBENDSGO")
#! Field("MGNT:SPD:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLBENDSGO.DOL1")
#! Field("MGNT:SPD:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLBENDSGO.LNK1")
#! Link("MGNT:SPD:1:ALLBENDSGO.LNK1","MGNT:SPD:1:ALLBENDS.VAL")
#! Record("MGNT:SPD:1:ALLBENDS",540,102,0,0,"MGNT:SPD:1:ALLBENDS")
#! Field("MGNT:SPD:1:ALLBENDS.VAL",16777215,0,"MGNT:SPD:1:ALLBENDS.VAL")
#! Field("MGNT:SPD:1:ALLBENDS.FLNK",16777215,1,"MGNT:SPD:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:SPD:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SPD:1:BTRMSWITCH")
}

record(seq, "MGNT:SPD:1:BTRMSWITCH") {
  field(DOL1, "MGNT:SPD:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:BTRMCTRL")
}

record(seq, "MGNT:SPD:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:BTRMCTRL",20,10,0,0,"MGNT:SPD:1:BTRMCTRL")
#! Field("MGNT:SPD:1:BTRMCTRL.FLNK",16777215,1,"MGNT:SPD:1:BTRMCTRL.FLNK")
#! Link("MGNT:SPD:1:BTRMCTRL.FLNK","MGNT:SPD:1:BTRMSWITCH")
#! Field("MGNT:SPD:1:BTRMCTRL.FFVL",16777215,1,"MGNT:SPD:1:BTRMCTRL.FFVL")
#! Record("MGNT:SPD:1:BTRMSWITCH",460,322,0,0,"MGNT:SPD:1:BTRMSWITCH")
#! Field("MGNT:SPD:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:SPD:1:BTRMSWITCH.DOL1")
#! Link("MGNT:SPD:1:BTRMSWITCH.DOL1","MGNT:SPD:1:BTRMCTRL.FFVL")
#! Field("MGNT:SPD:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:SPD:1:BTRMSWITCH.LNK1")
#! Field("MGNT:SPD:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:SPD:1:BTRMSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLBTRMSGO",240,96,0,0,"MGNT:SPD:1:ALLBTRMSGO")
#! Field("MGNT:SPD:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:SPD:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:SPD:1:ALLBTRMSGO.LNK1","MGNT:SPD:1:ALLBTRMS.VAL")
#! Record("MGNT:SPD:1:ALLBTRMS",540,102,0,0,"MGNT:SPD:1:ALLBTRMS")
#! Field("MGNT:SPD:1:ALLBTRMS.VAL",16777215,0,"MGNT:SPD:1:ALLBTRMS.VAL")
#! Field("MGNT:SPD:1:ALLBTRMS.FLNK",16777215,1,"MGNT:SPD:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:SPD:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:SPD:1:LGPSSWITCH")
}

record(seq, "MGNT:SPD:1:LGPSSWITCH") {
  field(DOL1, "MGNT:SPD:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:LGPSCTRL")
}

record(seq, "MGNT:SPD:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:LGPSCTRL",20,10,0,0,"MGNT:SPD:1:LGPSCTRL")
#! Field("MGNT:SPD:1:LGPSCTRL.FLNK",16777215,1,"MGNT:SPD:1:LGPSCTRL.FLNK")
#! Link("MGNT:SPD:1:LGPSCTRL.FLNK","MGNT:SPD:1:LGPSSWITCH")
#! Field("MGNT:SPD:1:LGPSCTRL.FFVL",16777215,1,"MGNT:SPD:1:LGPSCTRL.FFVL")
#! Record("MGNT:SPD:1:LGPSSWITCH",460,322,0,0,"MGNT:SPD:1:LGPSSWITCH")
#! Field("MGNT:SPD:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:SPD:1:LGPSSWITCH.DOL1")
#! Link("MGNT:SPD:1:LGPSSWITCH.DOL1","MGNT:SPD:1:LGPSCTRL.FFVL")
#! Field("MGNT:SPD:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:SPD:1:LGPSSWITCH.LNK1")
#! Field("MGNT:SPD:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:SPD:1:LGPSSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLLGPSSGO",240,96,0,0,"MGNT:SPD:1:ALLLGPSSGO")
#! Field("MGNT:SPD:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:SPD:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:SPD:1:ALLLGPSSGO.LNK1","MGNT:SPD:1:ALLLGPSS.VAL")
#! Record("MGNT:SPD:1:ALLLGPSS",540,102,0,0,"MGNT:SPD:1:ALLLGPSS")
#! Field("MGNT:SPD:1:ALLLGPSS.VAL",16777215,0,"MGNT:SPD:1:ALLLGPSS.VAL")
#! Field("MGNT:SPD:1:ALLLGPSS.FLNK",16777215,1,"MGNT:SPD:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:SPD:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:SPD:1:QUADSWITCH")
}

record(seq, "MGNT:SPD:1:QUADSWITCH") {
  field(DOL1, "MGNT:SPD:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:QUADCTRL")
}

record(seq, "MGNT:SPD:1:ALLQUADSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:QUADCTRL",20,10,0,0,"MGNT:SPD:1:QUADCTRL")
#! Field("MGNT:SPD:1:QUADCTRL.FLNK",16777215,1,"MGNT:SPD:1:QUADCTRL.FLNK")
#! Link("MGNT:SPD:1:QUADCTRL.FLNK","MGNT:SPD:1:QUADSWITCH")
#! Field("MGNT:SPD:1:QUADCTRL.FFVL",16777215,1,"MGNT:SPD:1:QUADCTRL.FFVL")
#! Record("MGNT:SPD:1:QUADSWITCH",460,322,0,0,"MGNT:SPD:1:QUADSWITCH")
#! Field("MGNT:SPD:1:QUADSWITCH.DOL1",16777215,0,"MGNT:SPD:1:QUADSWITCH.DOL1")
#! Link("MGNT:SPD:1:QUADSWITCH.DOL1","MGNT:SPD:1:QUADCTRL.FFVL")
#! Field("MGNT:SPD:1:QUADSWITCH.LNK1",16777215,1,"MGNT:SPD:1:QUADSWITCH.LNK1")
#! Field("MGNT:SPD:1:QUADSWITCH.FLNK",16777215,1,"MGNT:SPD:1:QUADSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLQUADSGO",240,96,0,0,"MGNT:SPD:1:ALLQUADSGO")
#! Field("MGNT:SPD:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLQUADSGO.DOL1")
#! Field("MGNT:SPD:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLQUADSGO.LNK1")
#! Link("MGNT:SPD:1:ALLQUADSGO.LNK1","MGNT:SPD:1:ALLQUADS.VAL")
#! Record("MGNT:SPD:1:ALLQUADS",540,102,0,0,"MGNT:SPD:1:ALLQUADS")
#! Field("MGNT:SPD:1:ALLQUADS.VAL",16777215,0,"MGNT:SPD:1:ALLQUADS.VAL")
#! Field("MGNT:SPD:1:ALLQUADS.FLNK",16777215,1,"MGNT:SPD:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:SPD:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:SPD:1:XCORSWITCH")
}

record(seq, "MGNT:SPD:1:XCORSWITCH") {
  field(DOL1, "MGNT:SPD:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:XCORCTRL")
}

record(seq, "MGNT:SPD:1:ALLXCORSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:XCORCTRL",20,10,0,0,"MGNT:SPD:1:XCORCTRL")
#! Field("MGNT:SPD:1:XCORCTRL.FLNK",16777215,1,"MGNT:SPD:1:XCORCTRL.FLNK")
#! Link("MGNT:SPD:1:XCORCTRL.FLNK","MGNT:SPD:1:XCORSWITCH")
#! Field("MGNT:SPD:1:XCORCTRL.FFVL",16777215,1,"MGNT:SPD:1:XCORCTRL.FFVL")
#! Record("MGNT:SPD:1:XCORSWITCH",460,322,0,0,"MGNT:SPD:1:XCORSWITCH")
#! Field("MGNT:SPD:1:XCORSWITCH.DOL1",16777215,0,"MGNT:SPD:1:XCORSWITCH.DOL1")
#! Link("MGNT:SPD:1:XCORSWITCH.DOL1","MGNT:SPD:1:XCORCTRL.FFVL")
#! Field("MGNT:SPD:1:XCORSWITCH.LNK1",16777215,1,"MGNT:SPD:1:XCORSWITCH.LNK1")
#! Field("MGNT:SPD:1:XCORSWITCH.FLNK",16777215,1,"MGNT:SPD:1:XCORSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLXCORSGO",240,96,0,0,"MGNT:SPD:1:ALLXCORSGO")
#! Field("MGNT:SPD:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLXCORSGO.DOL1")
#! Field("MGNT:SPD:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLXCORSGO.LNK1")
#! Link("MGNT:SPD:1:ALLXCORSGO.LNK1","MGNT:SPD:1:ALLXCORS.VAL")
#! Record("MGNT:SPD:1:ALLXCORS",540,102,0,0,"MGNT:SPD:1:ALLXCORS")
#! Field("MGNT:SPD:1:ALLXCORS.VAL",16777215,0,"MGNT:SPD:1:ALLXCORS.VAL")
#! Field("MGNT:SPD:1:ALLXCORS.FLNK",16777215,1,"MGNT:SPD:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:SPD:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:SPD:1:YCORSWITCH")
}

record(seq, "MGNT:SPD:1:YCORSWITCH") {
  field(DOL1, "MGNT:SPD:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:YCORCTRL")
}

record(seq, "MGNT:SPD:1:ALLYCORSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:YCORCTRL",20,10,0,0,"MGNT:SPD:1:YCORCTRL")
#! Field("MGNT:SPD:1:YCORCTRL.FLNK",16777215,1,"MGNT:SPD:1:YCORCTRL.FLNK")
#! Link("MGNT:SPD:1:YCORCTRL.FLNK","MGNT:SPD:1:YCORSWITCH")
#! Field("MGNT:SPD:1:YCORCTRL.FFVL",16777215,1,"MGNT:SPD:1:YCORCTRL.FFVL")
#! Record("MGNT:SPD:1:YCORSWITCH",460,322,0,0,"MGNT:SPD:1:YCORSWITCH")
#! Field("MGNT:SPD:1:YCORSWITCH.DOL1",16777215,0,"MGNT:SPD:1:YCORSWITCH.DOL1")
#! Link("MGNT:SPD:1:YCORSWITCH.DOL1","MGNT:SPD:1:YCORCTRL.FFVL")
#! Field("MGNT:SPD:1:YCORSWITCH.LNK1",16777215,1,"MGNT:SPD:1:YCORSWITCH.LNK1")
#! Field("MGNT:SPD:1:YCORSWITCH.FLNK",16777215,1,"MGNT:SPD:1:YCORSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLYCORSGO",240,96,0,0,"MGNT:SPD:1:ALLYCORSGO")
#! Field("MGNT:SPD:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLYCORSGO.DOL1")
#! Field("MGNT:SPD:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLYCORSGO.LNK1")
#! Link("MGNT:SPD:1:ALLYCORSGO.LNK1","MGNT:SPD:1:ALLYCORS.VAL")
#! Record("MGNT:SPD:1:ALLYCORS",540,102,0,0,"MGNT:SPD:1:ALLYCORS")
#! Field("MGNT:SPD:1:ALLYCORS.VAL",16777215,0,"MGNT:SPD:1:ALLYCORS.VAL")
#! Field("MGNT:SPD:1:ALLYCORS.FLNK",16777215,1,"MGNT:SPD:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:SPD:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:SPD:1:SOLNSWITCH")
}

record(seq, "MGNT:SPD:1:SOLNSWITCH") {
  field(DOL1, "MGNT:SPD:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:SOLNCTRL")
}

record(seq, "MGNT:SPD:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:SOLNCTRL",20,10,0,0,"MGNT:SPD:1:SOLNCTRL")
#! Field("MGNT:SPD:1:SOLNCTRL.FLNK",16777215,1,"MGNT:SPD:1:SOLNCTRL.FLNK")
#! Link("MGNT:SPD:1:SOLNCTRL.FLNK","MGNT:SPD:1:SOLNSWITCH")
#! Field("MGNT:SPD:1:SOLNCTRL.FFVL",16777215,1,"MGNT:SPD:1:SOLNCTRL.FFVL")
#! Record("MGNT:SPD:1:SOLNSWITCH",460,322,0,0,"MGNT:SPD:1:SOLNSWITCH")
#! Field("MGNT:SPD:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:SPD:1:SOLNSWITCH.DOL1")
#! Link("MGNT:SPD:1:SOLNSWITCH.DOL1","MGNT:SPD:1:SOLNCTRL.FFVL")
#! Field("MGNT:SPD:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:SPD:1:SOLNSWITCH.LNK1")
#! Field("MGNT:SPD:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:SPD:1:SOLNSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLSOLNSGO",240,96,0,0,"MGNT:SPD:1:ALLSOLNSGO")
#! Field("MGNT:SPD:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:SPD:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:SPD:1:ALLSOLNSGO.LNK1","MGNT:SPD:1:ALLSOLNS.VAL")
#! Record("MGNT:SPD:1:ALLSOLNS",540,102,0,0,"MGNT:SPD:1:ALLSOLNS")
#! Field("MGNT:SPD:1:ALLSOLNS.VAL",16777215,0,"MGNT:SPD:1:ALLSOLNS.VAL")
#! Field("MGNT:SPD:1:ALLSOLNS.FLNK",16777215,1,"MGNT:SPD:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:SPD:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:SPD:1:KICKSWITCH")
}

record(seq, "MGNT:SPD:1:KICKSWITCH") {
  field(DOL1, "MGNT:SPD:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:KICKCTRL")
}

record(seq, "MGNT:SPD:1:ALLKICKSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:KICKCTRL",20,10,0,0,"MGNT:SPD:1:KICKCTRL")
#! Field("MGNT:SPD:1:KICKCTRL.FLNK",16777215,1,"MGNT:SPD:1:KICKCTRL.FLNK")
#! Link("MGNT:SPD:1:KICKCTRL.FLNK","MGNT:SPD:1:KICKSWITCH")
#! Field("MGNT:SPD:1:KICKCTRL.FFVL",16777215,1,"MGNT:SPD:1:KICKCTRL.FFVL")
#! Record("MGNT:SPD:1:KICKSWITCH",460,322,0,0,"MGNT:SPD:1:KICKSWITCH")
#! Field("MGNT:SPD:1:KICKSWITCH.DOL1",16777215,0,"MGNT:SPD:1:KICKSWITCH.DOL1")
#! Link("MGNT:SPD:1:KICKSWITCH.DOL1","MGNT:SPD:1:KICKCTRL.FFVL")
#! Field("MGNT:SPD:1:KICKSWITCH.LNK1",16777215,1,"MGNT:SPD:1:KICKSWITCH.LNK1")
#! Field("MGNT:SPD:1:KICKSWITCH.FLNK",16777215,1,"MGNT:SPD:1:KICKSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLKICKSGO",240,96,0,0,"MGNT:SPD:1:ALLKICKSGO")
#! Field("MGNT:SPD:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLKICKSGO.DOL1")
#! Field("MGNT:SPD:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLKICKSGO.LNK1")
#! Link("MGNT:SPD:1:ALLKICKSGO.LNK1","MGNT:SPD:1:ALLKICKS.VAL")
#! Record("MGNT:SPD:1:ALLKICKS",540,102,0,0,"MGNT:SPD:1:ALLKICKS")
#! Field("MGNT:SPD:1:ALLKICKS.VAL",16777215,0,"MGNT:SPD:1:ALLKICKS.VAL")
#! Field("MGNT:SPD:1:ALLKICKS.FLNK",16777215,1,"MGNT:SPD:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:SPD:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:SPD:1:SEXTSWITCH")
}

record(seq, "MGNT:SPD:1:SEXTSWITCH") {
  field(DOL1, "MGNT:SPD:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:SPD:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:SPD:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:SPD:1:SEXTCTRL")
}

record(seq, "MGNT:SPD:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:SPD:1:ALLSTAR")
  field(LNK1, "MGNT:SPD:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:SPD:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:SPD:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:SPD:1:SEXTCTRL",20,10,0,0,"MGNT:SPD:1:SEXTCTRL")
#! Field("MGNT:SPD:1:SEXTCTRL.FLNK",16777215,1,"MGNT:SPD:1:SEXTCTRL.FLNK")
#! Link("MGNT:SPD:1:SEXTCTRL.FLNK","MGNT:SPD:1:SEXTSWITCH")
#! Field("MGNT:SPD:1:SEXTCTRL.FFVL",16777215,1,"MGNT:SPD:1:SEXTCTRL.FFVL")
#! Record("MGNT:SPD:1:SEXTSWITCH",460,322,0,0,"MGNT:SPD:1:SEXTSWITCH")
#! Field("MGNT:SPD:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:SPD:1:SEXTSWITCH.DOL1")
#! Link("MGNT:SPD:1:SEXTSWITCH.DOL1","MGNT:SPD:1:SEXTCTRL.FFVL")
#! Field("MGNT:SPD:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:SPD:1:SEXTSWITCH.LNK1")
#! Field("MGNT:SPD:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:SPD:1:SEXTSWITCH.FLNK")
#! Record("MGNT:SPD:1:ALLSEXTSGO",240,96,0,0,"MGNT:SPD:1:ALLSEXTSGO")
#! Field("MGNT:SPD:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:SPD:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:SPD:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:SPD:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:SPD:1:ALLSEXTSGO.LNK1","MGNT:SPD:1:ALLSEXTS.VAL")
#! Record("MGNT:SPD:1:ALLSEXTS",540,102,0,0,"MGNT:SPD:1:ALLSEXTS")
#! Field("MGNT:SPD:1:ALLSEXTS.VAL",16777215,0,"MGNT:SPD:1:ALLSEXTS.VAL")
#! Field("MGNT:SPD:1:ALLSEXTS.FLNK",16777215,1,"MGNT:SPD:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND

record(seq, "MGNT:SPH:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:SPH:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:SPH:1:ALLLGPSSSEL") {
}
record(seq, "MGNT:SPH:1:ALLKICKSSEL") {
  field(DOL1, "MGNT:SPH:1:ALLKICKS")
  field(LNK1, "KICK:SPH:110:SELECT CPP NMS")
}

record(seq, "MGNT:SPH:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:SPH:1:ALLBENDS")
  field(DOL2, "MGNT:SPH:1:ALLBENDS")
  field(DOL3, "MGNT:SPH:1:ALLBENDS")
  field(DOL4, "MGNT:SPH:1:ALLBENDS")
  field(LNK1, "BEND:SPH:270:SELECT CPP NMS")
  field(LNK2, "BEND:SPH:310:SELECT CPP NMS")
  field(LNK3, "BEND:SLTH:145:SELECT CPP NMS")
  field(LNK4, "BEND:SLTH:435:SELECT CPP NMS")
}

record(seq, "MGNT:SPH:1:ALLBTRMSSEL") {
   field(DOL1, "MGNT:SPH:1:ALLBTRMS")
   field(DOL2, "MGNT:SPH:1:ALLBTRMS")
   field(LNK1, "BTRM:SPH:170:SELECT CPP NMS")
   field(LNK2, "BTRM:SPH:370:SELECT CPP NMS")
}

record(seq, "MGNT:SPH:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:SPH:1:ALLQUADS")
  field(DOL2, "MGNT:SPH:1:ALLQUADS")
  field(DOL3, "MGNT:SPH:1:ALLQUADS")
  field(DOL4, "MGNT:SPH:1:ALLQUADS")
  field(DOL5, "MGNT:SPH:1:ALLQUADS")
  field(DOL6, "MGNT:SPH:1:ALLQUADS")
  field(DOL7, "MGNT:SPH:1:ALLQUADS")
  field(LNK1, "QUAD:SPH:320:SELECT CPP NMS")
  field(LNK2, "QUAD:SPH:345:SELECT CPP NMS")
  field(LNK3, "QUAD:SPH:420:SELECT CPP NMS")
  field(LNK4, "QUAD:SPH:450:SELECT CPP NMS")
  field(LNK5, "QUAD:SPH:520:SELECT CPP NMS")
  field(LNK6, "QUAD:SPH:600:SELECT CPP NMS")
  field(LNK7, "QUAD:SPH:675:SELECT CPP NMS")
}

record(seq, "MGNT:SPH:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:SPH:1:ALLXCORS")
  field(DOL2, "MGNT:SPH:1:ALLXCORS")
  field(DOL3, "MGNT:SPH:1:ALLXCORS")
  field(DOL4, "MGNT:SPH:1:ALLXCORS")
  field(DOL5, "MGNT:SPH:1:ALLXCORS")
  field(DOL6, "MGNT:SPH:1:ALLXCORS")
  field(LNK1, "XCOR:SPH:324:SELECT CPP NMS")
  field(LNK2, "XCOR:SPH:414:SELECT CPP NMS")
  field(LNK3, "XCOR:SPH:516:SELECT CPP NMS")
  field(LNK4, "XCOR:SPH:684:SELECT CPP NMS")
  field(LNK5, "XCOR:SPH:844:SELECT CPP NMS")
  field(LNK6, "XCOR:SPH:938:SELECT CPP NMS")
}

record(seq, "MGNT:SPH:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:SPH:1:ALLYCORS")
  field(DOL2, "MGNT:SPH:1:ALLYCORS")
  field(DOL3, "MGNT:SPH:1:ALLYCORS")
  field(DOL4, "MGNT:SPH:1:ALLYCORS")
  field(DOL5, "MGNT:SPH:1:ALLYCORS")
  field(LNK1, "YCOR:SPH:346:SELECT CPP NMS")
  field(LNK2, "YCOR:SPH:447:SELECT CPP NMS")
  field(LNK3, "YCOR:SPH:597:SELECT CPP NMS")
  field(LNK4, "YCOR:SPH:757:SELECT CPP NMS")
  field(LNK5, "YCOR:SPH:917:SELECT CPP NMS")

}

record(seq, "MGNT:SPH:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:SPH:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:SPH:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:SPH:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:SPH:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:SPH:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:SPH:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:SPH:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:SPH:1:ALLFUNCGO2")
}
record(seq, "MGNT:SPH:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:SPH:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:SPH:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:SPH:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:SPH:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}
record(fanout, "MGNT:SPH:1:KICKFUNCGO") {
  field(DESC, "Process All KICKs")
  field(LNK1, "KICK:SPH:110:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:SLTH:145:ALLFUNCGO")
  field(LNK2, "BEND:SPH:270:ALLFUNCGO")
  field(LNK3, "BEND:SPH:310:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:SPH:170:ALLFUNCGO")
  field(LNK2, "BTRM:SPH:370:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:SPH:320:ALLFUNCGO")
  field(LNK2, "QUAD:SPH:345:ALLFUNCGO")
  field(LNK3, "QUAD:SPH:420:ALLFUNCGO")
  field(LNK4, "QUAD:SPH:450:ALLFUNCGO")
  field(LNK5, "QUAD:SPH:520:ALLFUNCGO")
  field(LNK6, "QUAD:SPH:600:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:SPH:1:QUADFUNCGO_2") {
  field(DESC, "Process QUAD CTRL func 2")
  field(LNK1, "QUAD:SPH:675:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:SPH:324:ALLFUNCGO")
  field(LNK2, "XCOR:SPH:414:ALLFUNCGO")
  field(LNK3, "XCOR:SPH:516:ALLFUNCGO")
  field(LNK4, "XCOR:SPH:684:ALLFUNCGO")
  field(LNK5, "XCOR:SPH:844:ALLFUNCGO")
  field(LNK6, "XCOR:SPH:938:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPH:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:SPH:346:ALLFUNCGO")
  field(LNK2, "YCOR:SPH:447:ALLFUNCGO")
  field(LNK3, "YCOR:SPH:597:ALLFUNCGO")
  field(LNK4, "YCOR:SPH:757:ALLFUNCGO")
  field(LNK5, "YCOR:SPH:917:ALLFUNCGO")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}


record(fanout, "MGNT:SPH:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(FLNK, "MGNT:SPH:1:CTRLCLEAR")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:SPS:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:SPS:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:SPS:1:ALLLGPSSSEL") {
}
record(seq, "MGNT:SPS:1:ALLKICKSSEL") {
  field(DOL1, "MGNT:SPS:1:ALLKICKS")
  field(LNK1, "KICK:SPS:385:SELECT CPP NMS")
}
record(seq, "MGNT:SPS:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:SPS:1:ALLBENDS")
  field(DOL2, "MGNT:SPS:1:ALLBENDS")
  field(DOL3, "MGNT:SPS:1:ALLBENDS")
  field(LNK1, "BEND:SPS:530:SELECT CPP NMS")
  field(LNK2, "BEND:SPS:560:SELECT CPP NMS")
  field(LNK3, "BEND:SPS:800:SELECT CPP NMS")
}

record(seq, "MGNT:SPS:1:ALLBTRMSSEL") {
   field(DOL1, "MGNT:SPS:1:ALLBTRMS")
   field(DOL2, "MGNT:SPS:1:ALLBTRMS")
   field(DOL3, "MGNT:SPS:1:ALLBTRMS")
   field(LNK1, "BTRM:SPS:610:SELECT CPP NMS")
   field(LNK2, "BTRM:SPS:950:SELECT CPP NMS")
   field(LNK3, "BTRM:SPS:470:SELECT CPP NMS")
}

record(seq, "MGNT:SPS:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:SPS:1:ALLQUADS")
  field(DOL2, "MGNT:SPS:1:ALLQUADS")
  field(DOL3, "MGNT:SPS:1:ALLQUADS")
  field(DOL4, "MGNT:SPS:1:ALLQUADS")
  field(DOL5, "MGNT:SPS:1:ALLQUADS")
  field(LNK1, "QUAD:SPS:570:SELECT CPP NMS")
  field(LNK2, "QUAD:SPS:580:SELECT CPP NMS")
  field(LNK3, "QUAD:SPS:640:SELECT CPP NMS")
  field(LNK4, "QUAD:SPS:650:SELECT CPP NMS")
  field(LNK5, "QUAD:SPS:710:SELECT CPP NMS")
}

record(seq, "MGNT:SPS:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:SPS:1:ALLXCORS")
  field(DOL2, "MGNT:SPS:1:ALLXCORS")
  field(DOL3, "MGNT:SPS:1:ALLXCORS")
  field(DOL4, "MGNT:SPS:1:ALLXCORS")
  field(DOL5, "MGNT:SPS:1:ALLXCORS")
  field(LNK1, "XCOR:SPS:578:SELECT CPP NMS")
  field(LNK2, "XCOR:SPS:634:SELECT CPP NMS")
  field(LNK3, "XCOR:SPS:706:SELECT CPP NMS")
  field(LNK4, "XCOR:SPS:776:SELECT CPP NMS")
  field(LNK5, "XCOR:SPS:836:SELECT CPP NMS")
}

record(seq, "MGNT:SPS:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:SPS:1:ALLYCORS")
  field(DOL2, "MGNT:SPS:1:ALLYCORS")
  field(DOL3, "MGNT:SPS:1:ALLYCORS")
  field(DOL4, "MGNT:SPS:1:ALLYCORS")
  field(LNK1, "YCOR:SPS:587:SELECT CPP NMS")
  field(LNK2, "YCOR:SPS:643:SELECT CPP NMS")
  field(LNK3, "YCOR:SPS:767:SELECT CPP NMS")
  field(LNK4, "YCOR:SPS:827:SELECT CPP NMS")
}

record(seq, "MGNT:SPS:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:SPS:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:SPS:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:SPS:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:SPS:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:SPS:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:SPS:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:SPS:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:SPS:1:ALLFUNCGO2")
}
record(seq, "MGNT:SPS:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:SPS:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:SPS:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:SPS:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:SPS:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}
record(fanout, "MGNT:SPS:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(LNK1, "KICK:SPS:385:ALLFUNCGO")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}
record(fanout, "MGNT:SPS:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:SPS:530:ALLFUNCGO")
  field(LNK2, "BEND:SPS:560:ALLFUNCGO")
  field(LNK2, "BEND:SPS:800:ALLFUNCGO")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:SPS:610:ALLFUNCGO")
  field(LNK2, "BTRM:SPS:950:ALLFUNCGO")
  field(LNK3, "BTRM:SPS:470:ALLFUNCGO")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:SPS:570:ALLFUNCGO")
  field(LNK2, "QUAD:SPS:580:ALLFUNCGO")
  field(LNK3, "QUAD:SPS:640:ALLFUNCGO")
  field(LNK4, "QUAD:SPS:650:ALLFUNCGO")
  field(LNK5, "QUAD:SPS:710:ALLFUNCGO")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:SPS:578:ALLFUNCGO")
  field(LNK2, "XCOR:SPS:634:ALLFUNCGO")
  field(LNK3, "XCOR:SPS:706:ALLFUNCGO")
  field(LNK4, "XCOR:SPS:776:ALLFUNCGO")
  field(LNK5, "XCOR:SPS:836:ALLFUNCGO")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:SPS:587:ALLFUNCGO")
  field(LNK2, "YCOR:SPS:643:ALLFUNCGO")
  field(LNK3, "YCOR:SPS:767:ALLFUNCGO")
  field(LNK4, "YCOR:SPS:827:ALLFUNCGO")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPS:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(FLNK, "MGNT:SPS:1:CTRLCLEAR")
}
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:SPD:1:ALLSOLNSSEL") {
}
record(seq, "MGNT:SPD:1:ALLKICKSSEL") {
}
record(seq, "MGNT:SPD:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:SPD:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:SPD:1:ALLLGPSS")
  field(LNK1, "LGPS:BSYS:1:SELECT CPP NMS")
}

record(seq, "MGNT:SPD:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:SPD:1:ALLBENDS")
  field(LNK1, "BEND:SPD:960:SELECT CPP NMS")
}

record(seq, "MGNT:SPD:1:ALLBTRMSSEL") {
   field(DOL1, "MGNT:SPD:1:ALLBTRMS")
   field(LNK1, "BTRM:SPD:719:SELECT CPP NMS")
}

record(seq, "MGNT:SPD:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:SPD:1:ALLQUADS")
  field(DOL2, "MGNT:SPD:1:ALLQUADS")
  field(DOL3, "MGNT:SPD:1:ALLQUADS")
  field(DOL4, "MGNT:SPD:1:ALLQUADS")
  field(LNK1, "QUAD:SPD:330:SELECT CPP NMS")
  field(LNK2, "QUAD:SPD:340:SELECT CPP NMS")
  field(LNK3, "QUAD:SPD:690:SELECT CPP NMS")
  field(LNK4, "QUAD:SPD:700:SELECT CPP NMS")
}

record(seq, "MGNT:SPD:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:SPD:1:ALLXCORS")
  field(DOL2, "MGNT:SPD:1:ALLXCORS")
  field(DOL3, "MGNT:SPD:1:ALLXCORS")
  field(LNK1, "XCOR:SPD:334:SELECT CPP NMS")
  field(LNK2, "XCOR:SPD:688:SELECT CPP NMS")
  field(LNK3, "XCOR:SPD:964:SELECT CPP NMS")
}

record(seq, "MGNT:SPD:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:SPD:1:ALLYCORS")
  field(DOL2, "MGNT:SPD:1:ALLYCORS")
  field(DOL3, "MGNT:SPD:1:ALLYCORS")
  field(LNK1, "YCOR:SPD:343:SELECT CPP NMS")
  field(LNK2, "YCOR:SPD:703:SELECT CPP NMS")
  field(LNK3, "YCOR:SPD:965:SELECT CPP NMS")
}

record(seq, "MGNT:SPD:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:SPD:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:SPD:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:SPD:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:SPD:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:SPD:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:SPD:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:SPD:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:SPD:1:ALLFUNCGO2")
}
record(seq, "MGNT:SPD:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:SPD:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:SPD:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:SPD:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:SPD:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}
record(fanout, "MGNT:SPD:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}
record(fanout, "MGNT:SPD:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:SPD:960:ALLFUNCGO")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(LNK1, "BTRM:SPD:719:ALLFUNCGO")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:SPD:330:ALLFUNCGO")
  field(LNK2, "QUAD:SPD:340:ALLFUNCGO")
  field(LNK3, "QUAD:SPD:690:ALLFUNCGO")
  field(LNK4, "QUAD:SPD:700:ALLFUNCGO")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:SPD:334:ALLFUNCGO")
  field(LNK2, "XCOR:SPD:688:ALLFUNCGO")
  field(LNK3, "XCOR:SPD:964:ALLFUNCGO")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:SPD:343:ALLFUNCGO")
  field(LNK2, "YCOR:SPD:703:ALLFUNCGO")
  field(LNK3, "YCOR:SPD:965:ALLFUNCGO")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}

record(fanout, "MGNT:SPD:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:BSYS:1:ALLFUNCGO")
  field(FLNK, "MGNT:SPD:1:CTRLCLEAR")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:SPH:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "KICK:SPH:110:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:SPH:110:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:SPH:110:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:SPH:110:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:SPH:110:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:SPH:110:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:SPH:110:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:SPH:110:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:SPH:110:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:SPH:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:SPH:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:SPH:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:SPH:110:EDES.PROC PP")
    field(LNK2, "KICK:SPH:110:EACT.PROC PP")
    field(LNK3, "KICK:SPH:110:EERR.DISA PP")
    field(LNK4, "KICK:SPH:110:ECON.PROC PP")
    field(LNK5, "KICK:SPH:110:BMAGX.PROC PP")
    field(LNK6, "KICK:SPH:110:BMAGY.PROC PP")
    field(LNK7, "KICK:SPH:110:BLEM.PROC PP")
    field(LNK8, "KICK:SPH:110:BMOD.PROC PP")
    field(LNK9, "KICK:SPH:110:EDESSAVE.PROC PP")
    field(LNKA, "KICK:SPH:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:SPH:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:SPH:110:BMAX")
  field(DOL2, "KICK:SPH:110:BMAX")
  field(DOL3, "KICK:SPH:110:BMAX")
  field(DOL4, "KICK:SPH:110:BMIN")
  field(DOL5, "KICK:SPH:110:BMIN")
  field(DOL6, "KICK:SPH:110:BMIN")
  field(LNK1, "KICK:SPH:110:BMAGX.HOPR")
  field(LNK2, "KICK:SPH:110:BMAGY.HOPR")
  field(LNK3, "KICK:SPH:110:BLEM.HOPR")
  field(LNK4, "KICK:SPH:110:BMAGX.LOPR PP")
  field(LNK5, "KICK:SPH:110:BMAGY.LOPR PP")
  field(LNK6, "KICK:SPH:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:SPH:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:SPH:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:SPH:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:SPH:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:SPH:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:SPH:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:SPH:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:SPH:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:SPH:110:EDES NPP MS")
  field(INPB, "KICK:SPH:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPH:270:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "BEND:SPH:270:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPH:270:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPH:270:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPH:270:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPH:270:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPH:270:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPH:270:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPH:270:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPH:270:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPH:270:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPH:270:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPH:270:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPH:270:EDES.PROC PP")
    field(LNK2, "BEND:SPH:270:EACT.PROC PP")
    field(LNK3, "BEND:SPH:270:EERR.DISA PP")
    field(LNK4, "BEND:SPH:270:ECON.PROC PP")
    field(LNK5, "BEND:SPH:270:BMAGX.PROC PP")
    field(LNK6, "BEND:SPH:270:BMAGY.PROC PP")
    field(LNK7, "BEND:SPH:270:BLEM.PROC PP")
    field(LNK8, "BEND:SPH:270:BMOD.PROC PP")
    field(LNK9, "BEND:SPH:270:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPH:270:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPH:270:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPH:270:BMAX")
  field(DOL2, "BEND:SPH:270:BMAX")
  field(DOL3, "BEND:SPH:270:BMAX")
  field(DOL4, "BEND:SPH:270:BMIN")
  field(DOL5, "BEND:SPH:270:BMIN")
  field(DOL6, "BEND:SPH:270:BMIN")
  field(LNK1, "BEND:SPH:270:BMAGX.HOPR")
  field(LNK2, "BEND:SPH:270:BMAGY.HOPR")
  field(LNK3, "BEND:SPH:270:BLEM.HOPR")
  field(LNK4, "BEND:SPH:270:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPH:270:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPH:270:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:270:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:270:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPH:270:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPH:270:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPH:270:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:270:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:270:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPH:270:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:270:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPH:270:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPH:270:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPH:270:EDES NPP MS")
  field(INPB, "BEND:SPH:270:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPH:310:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "BEND:SPH:310:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPH:310:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPH:310:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPH:310:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPH:310:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPH:310:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPH:310:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPH:310:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPH:310:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPH:310:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPH:310:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPH:310:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPH:310:EDES.PROC PP")
    field(LNK2, "BEND:SPH:310:EACT.PROC PP")
    field(LNK3, "BEND:SPH:310:EERR.DISA PP")
    field(LNK4, "BEND:SPH:310:ECON.PROC PP")
    field(LNK5, "BEND:SPH:310:BMAGX.PROC PP")
    field(LNK6, "BEND:SPH:310:BMAGY.PROC PP")
    field(LNK7, "BEND:SPH:310:BLEM.PROC PP")
    field(LNK8, "BEND:SPH:310:BMOD.PROC PP")
    field(LNK9, "BEND:SPH:310:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPH:310:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPH:310:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPH:310:BMAX")
  field(DOL2, "BEND:SPH:310:BMAX")
  field(DOL3, "BEND:SPH:310:BMAX")
  field(DOL4, "BEND:SPH:310:BMIN")
  field(DOL5, "BEND:SPH:310:BMIN")
  field(DOL6, "BEND:SPH:310:BMIN")
  field(LNK1, "BEND:SPH:310:BMAGX.HOPR")
  field(LNK2, "BEND:SPH:310:BMAGY.HOPR")
  field(LNK3, "BEND:SPH:310:BLEM.HOPR")
  field(LNK4, "BEND:SPH:310:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPH:310:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPH:310:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:310:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPH:310:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPH:310:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPH:310:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPH:310:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:310:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:310:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPH:310:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPH:310:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPH:310:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPH:310:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPH:310:EDES NPP MS")
  field(INPB, "BEND:SPH:310:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:320:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:320:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:320:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:320:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:320:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:320:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:320:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:320:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:320:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:320:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:320:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:320:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:320:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:320:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:320:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:320:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:320:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:320:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:320:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:320:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:320:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:320:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:320:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:320:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:320:BMAX")
  field(DOL2, "QUAD:SPH:320:BMAX")
  field(DOL3, "QUAD:SPH:320:BMAX")
  field(DOL4, "QUAD:SPH:320:BMIN")
  field(DOL5, "QUAD:SPH:320:BMIN")
  field(DOL6, "QUAD:SPH:320:BMIN")
  field(LNK1, "QUAD:SPH:320:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:320:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:320:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:320:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:320:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:320:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:320:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:320:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:320:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:320:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:320:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:320:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:320:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:320:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:320:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:320:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:320:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:320:EDES NPP MS")
  field(INPB, "QUAD:SPH:320:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:345:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:345:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:345:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:345:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:345:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:345:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:345:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:345:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:345:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:345:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:345:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:345:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:345:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:345:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:345:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:345:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:345:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:345:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:345:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:345:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:345:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:345:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:345:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:345:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:345:BMAX")
  field(DOL2, "QUAD:SPH:345:BMAX")
  field(DOL3, "QUAD:SPH:345:BMAX")
  field(DOL4, "QUAD:SPH:345:BMIN")
  field(DOL5, "QUAD:SPH:345:BMIN")
  field(DOL6, "QUAD:SPH:345:BMIN")
  field(LNK1, "QUAD:SPH:345:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:345:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:345:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:345:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:345:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:345:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:345:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:345:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:345:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:345:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:345:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:345:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:345:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:345:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:345:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:345:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:345:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:345:EDES NPP MS")
  field(INPB, "QUAD:SPH:345:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:420:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:420:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:420:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:420:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:420:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:420:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:420:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:420:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:420:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:420:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:420:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:420:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:420:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:420:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:420:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:420:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:420:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:420:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:420:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:420:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:420:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:420:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:420:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:420:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:420:BMAX")
  field(DOL2, "QUAD:SPH:420:BMAX")
  field(DOL3, "QUAD:SPH:420:BMAX")
  field(DOL4, "QUAD:SPH:420:BMIN")
  field(DOL5, "QUAD:SPH:420:BMIN")
  field(DOL6, "QUAD:SPH:420:BMIN")
  field(LNK1, "QUAD:SPH:420:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:420:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:420:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:420:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:420:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:420:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:420:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:420:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:420:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:420:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:420:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:420:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:420:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:420:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:420:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:420:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:420:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:420:EDES NPP MS")
  field(INPB, "QUAD:SPH:420:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:450:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:450:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:450:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:450:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:450:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:450:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:450:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:450:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:450:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:450:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:450:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:450:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:450:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:450:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:450:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:450:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:450:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:450:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:450:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:450:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:450:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:450:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:450:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:450:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:450:BMAX")
  field(DOL2, "QUAD:SPH:450:BMAX")
  field(DOL3, "QUAD:SPH:450:BMAX")
  field(DOL4, "QUAD:SPH:450:BMIN")
  field(DOL5, "QUAD:SPH:450:BMIN")
  field(DOL6, "QUAD:SPH:450:BMIN")
  field(LNK1, "QUAD:SPH:450:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:450:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:450:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:450:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:450:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:450:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:450:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:450:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:450:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:450:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:450:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:450:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:450:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:450:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:450:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:450:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:450:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:450:EDES NPP MS")
  field(INPB, "QUAD:SPH:450:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:520:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:520:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:520:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:520:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:520:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:520:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:520:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:520:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:520:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:520:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:520:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:520:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:520:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:520:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:520:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:520:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:520:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:520:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:520:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:520:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:520:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:520:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:520:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:520:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:520:BMAX")
  field(DOL2, "QUAD:SPH:520:BMAX")
  field(DOL3, "QUAD:SPH:520:BMAX")
  field(DOL4, "QUAD:SPH:520:BMIN")
  field(DOL5, "QUAD:SPH:520:BMIN")
  field(DOL6, "QUAD:SPH:520:BMIN")
  field(LNK1, "QUAD:SPH:520:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:520:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:520:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:520:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:520:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:520:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:520:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:520:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:520:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:520:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:520:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:520:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:520:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:520:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:520:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:520:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:520:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:520:EDES NPP MS")
  field(INPB, "QUAD:SPH:520:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:600:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:600:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:600:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:600:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:600:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:600:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:600:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:600:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:600:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:600:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:600:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:600:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:600:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:600:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:600:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:600:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:600:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:600:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:600:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:600:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:600:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:600:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:600:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:600:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:600:BMAX")
  field(DOL2, "QUAD:SPH:600:BMAX")
  field(DOL3, "QUAD:SPH:600:BMAX")
  field(DOL4, "QUAD:SPH:600:BMIN")
  field(DOL5, "QUAD:SPH:600:BMIN")
  field(DOL6, "QUAD:SPH:600:BMIN")
  field(LNK1, "QUAD:SPH:600:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:600:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:600:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:600:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:600:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:600:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:600:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:600:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:600:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:600:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:600:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:600:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:600:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:600:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:600:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:600:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:600:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:600:EDES NPP MS")
  field(INPB, "QUAD:SPH:600:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:675:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:675:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:675:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:675:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:675:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:675:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:675:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:675:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:675:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:675:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:675:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:675:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:675:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:675:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:675:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:675:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:675:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:675:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:675:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:675:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:675:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:675:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:675:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:675:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:675:BMAX")
  field(DOL2, "QUAD:SPH:675:BMAX")
  field(DOL3, "QUAD:SPH:675:BMAX")
  field(DOL4, "QUAD:SPH:675:BMIN")
  field(DOL5, "QUAD:SPH:675:BMIN")
  field(DOL6, "QUAD:SPH:675:BMIN")
  field(LNK1, "QUAD:SPH:675:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:675:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:675:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:675:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:675:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:675:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:675:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:675:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:675:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:675:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:675:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:675:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:675:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:675:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:675:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPH:675:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:675:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:675:EDES NPP MS")
  field(INPB, "QUAD:SPH:675:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPH:324:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPH:324:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPH:324:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPH:324:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPH:324:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPH:324:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPH:324:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPH:324:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPH:324:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPH:324:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPH:324:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPH:324:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPH:324:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPH:324:EDES.PROC PP")
    field(LNK2, "XCOR:SPH:324:EACT.PROC PP")
    field(LNK3, "XCOR:SPH:324:EERR.DISA PP")
    field(LNK4, "XCOR:SPH:324:ECON.PROC PP")
    field(LNK5, "XCOR:SPH:324:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPH:324:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPH:324:BLEM.PROC PP")
    field(LNK8, "XCOR:SPH:324:BMOD.PROC PP")
    field(LNK9, "XCOR:SPH:324:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPH:324:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPH:324:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPH:324:BMAX")
  field(DOL2, "XCOR:SPH:324:BMAX")
  field(DOL3, "XCOR:SPH:324:BMAX")
  field(DOL4, "XCOR:SPH:324:BMIN")
  field(DOL5, "XCOR:SPH:324:BMIN")
  field(DOL6, "XCOR:SPH:324:BMIN")
  field(LNK1, "XCOR:SPH:324:BMAGX.HOPR")
  field(LNK2, "XCOR:SPH:324:BMAGY.HOPR")
  field(LNK3, "XCOR:SPH:324:BLEM.HOPR")
  field(LNK4, "XCOR:SPH:324:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPH:324:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPH:324:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:324:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:324:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPH:324:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPH:324:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPH:324:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:324:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:324:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:324:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:324:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:324:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPH:324:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPH:324:EDES NPP MS")
  field(INPB, "XCOR:SPH:324:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPH:414:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPH:414:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPH:414:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPH:414:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPH:414:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPH:414:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPH:414:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPH:414:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPH:414:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPH:414:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPH:414:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPH:414:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPH:414:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPH:414:EDES.PROC PP")
    field(LNK2, "XCOR:SPH:414:EACT.PROC PP")
    field(LNK3, "XCOR:SPH:414:EERR.DISA PP")
    field(LNK4, "XCOR:SPH:414:ECON.PROC PP")
    field(LNK5, "XCOR:SPH:414:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPH:414:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPH:414:BLEM.PROC PP")
    field(LNK8, "XCOR:SPH:414:BMOD.PROC PP")
    field(LNK9, "XCOR:SPH:414:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPH:414:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPH:414:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPH:414:BMAX")
  field(DOL2, "XCOR:SPH:414:BMAX")
  field(DOL3, "XCOR:SPH:414:BMAX")
  field(DOL4, "XCOR:SPH:414:BMIN")
  field(DOL5, "XCOR:SPH:414:BMIN")
  field(DOL6, "XCOR:SPH:414:BMIN")
  field(LNK1, "XCOR:SPH:414:BMAGX.HOPR")
  field(LNK2, "XCOR:SPH:414:BMAGY.HOPR")
  field(LNK3, "XCOR:SPH:414:BLEM.HOPR")
  field(LNK4, "XCOR:SPH:414:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPH:414:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPH:414:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:414:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:414:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPH:414:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPH:414:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPH:414:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:414:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:414:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:414:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:414:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:414:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPH:414:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPH:414:EDES NPP MS")
  field(INPB, "XCOR:SPH:414:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPH:516:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPH:516:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPH:516:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPH:516:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPH:516:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPH:516:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPH:516:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPH:516:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPH:516:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPH:516:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPH:516:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPH:516:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPH:516:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPH:516:EDES.PROC PP")
    field(LNK2, "XCOR:SPH:516:EACT.PROC PP")
    field(LNK3, "XCOR:SPH:516:EERR.DISA PP")
    field(LNK4, "XCOR:SPH:516:ECON.PROC PP")
    field(LNK5, "XCOR:SPH:516:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPH:516:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPH:516:BLEM.PROC PP")
    field(LNK8, "XCOR:SPH:516:BMOD.PROC PP")
    field(LNK9, "XCOR:SPH:516:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPH:516:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPH:516:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPH:516:BMAX")
  field(DOL2, "XCOR:SPH:516:BMAX")
  field(DOL3, "XCOR:SPH:516:BMAX")
  field(DOL4, "XCOR:SPH:516:BMIN")
  field(DOL5, "XCOR:SPH:516:BMIN")
  field(DOL6, "XCOR:SPH:516:BMIN")
  field(LNK1, "XCOR:SPH:516:BMAGX.HOPR")
  field(LNK2, "XCOR:SPH:516:BMAGY.HOPR")
  field(LNK3, "XCOR:SPH:516:BLEM.HOPR")
  field(LNK4, "XCOR:SPH:516:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPH:516:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPH:516:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:516:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:516:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPH:516:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPH:516:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPH:516:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:516:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:516:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:516:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:516:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:516:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPH:516:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPH:516:EDES NPP MS")
  field(INPB, "XCOR:SPH:516:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPH:684:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPH:684:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPH:684:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPH:684:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPH:684:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPH:684:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPH:684:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPH:684:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPH:684:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPH:684:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPH:684:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPH:684:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPH:684:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPH:684:EDES.PROC PP")
    field(LNK2, "XCOR:SPH:684:EACT.PROC PP")
    field(LNK3, "XCOR:SPH:684:EERR.DISA PP")
    field(LNK4, "XCOR:SPH:684:ECON.PROC PP")
    field(LNK5, "XCOR:SPH:684:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPH:684:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPH:684:BLEM.PROC PP")
    field(LNK8, "XCOR:SPH:684:BMOD.PROC PP")
    field(LNK9, "XCOR:SPH:684:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPH:684:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPH:684:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPH:684:BMAX")
  field(DOL2, "XCOR:SPH:684:BMAX")
  field(DOL3, "XCOR:SPH:684:BMAX")
  field(DOL4, "XCOR:SPH:684:BMIN")
  field(DOL5, "XCOR:SPH:684:BMIN")
  field(DOL6, "XCOR:SPH:684:BMIN")
  field(LNK1, "XCOR:SPH:684:BMAGX.HOPR")
  field(LNK2, "XCOR:SPH:684:BMAGY.HOPR")
  field(LNK3, "XCOR:SPH:684:BLEM.HOPR")
  field(LNK4, "XCOR:SPH:684:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPH:684:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPH:684:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:684:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:684:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPH:684:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPH:684:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPH:684:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:684:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:684:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:684:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:684:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:684:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPH:684:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPH:684:EDES NPP MS")
  field(INPB, "XCOR:SPH:684:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPH:844:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPH:844:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPH:844:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPH:844:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPH:844:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPH:844:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPH:844:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPH:844:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPH:844:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPH:844:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPH:844:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPH:844:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPH:844:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPH:844:EDES.PROC PP")
    field(LNK2, "XCOR:SPH:844:EACT.PROC PP")
    field(LNK3, "XCOR:SPH:844:EERR.DISA PP")
    field(LNK4, "XCOR:SPH:844:ECON.PROC PP")
    field(LNK5, "XCOR:SPH:844:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPH:844:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPH:844:BLEM.PROC PP")
    field(LNK8, "XCOR:SPH:844:BMOD.PROC PP")
    field(LNK9, "XCOR:SPH:844:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPH:844:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPH:844:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPH:844:BMAX")
  field(DOL2, "XCOR:SPH:844:BMAX")
  field(DOL3, "XCOR:SPH:844:BMAX")
  field(DOL4, "XCOR:SPH:844:BMIN")
  field(DOL5, "XCOR:SPH:844:BMIN")
  field(DOL6, "XCOR:SPH:844:BMIN")
  field(LNK1, "XCOR:SPH:844:BMAGX.HOPR")
  field(LNK2, "XCOR:SPH:844:BMAGY.HOPR")
  field(LNK3, "XCOR:SPH:844:BLEM.HOPR")
  field(LNK4, "XCOR:SPH:844:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPH:844:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPH:844:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:844:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:844:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPH:844:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPH:844:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPH:844:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:844:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:844:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:844:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:844:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:844:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPH:844:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPH:844:EDES NPP MS")
  field(INPB, "XCOR:SPH:844:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPH:938:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPH:938:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPH:938:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPH:938:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPH:938:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPH:938:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPH:938:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPH:938:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPH:938:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPH:938:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPH:938:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPH:938:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPH:938:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPH:938:EDES.PROC PP")
    field(LNK2, "XCOR:SPH:938:EACT.PROC PP")
    field(LNK3, "XCOR:SPH:938:EERR.DISA PP")
    field(LNK4, "XCOR:SPH:938:ECON.PROC PP")
    field(LNK5, "XCOR:SPH:938:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPH:938:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPH:938:BLEM.PROC PP")
    field(LNK8, "XCOR:SPH:938:BMOD.PROC PP")
    field(LNK9, "XCOR:SPH:938:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPH:938:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPH:938:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPH:938:BMAX")
  field(DOL2, "XCOR:SPH:938:BMAX")
  field(DOL3, "XCOR:SPH:938:BMAX")
  field(DOL4, "XCOR:SPH:938:BMIN")
  field(DOL5, "XCOR:SPH:938:BMIN")
  field(DOL6, "XCOR:SPH:938:BMIN")
  field(LNK1, "XCOR:SPH:938:BMAGX.HOPR")
  field(LNK2, "XCOR:SPH:938:BMAGY.HOPR")
  field(LNK3, "XCOR:SPH:938:BLEM.HOPR")
  field(LNK4, "XCOR:SPH:938:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPH:938:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPH:938:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:938:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPH:938:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPH:938:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPH:938:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPH:938:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:938:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:938:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:938:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPH:938:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPH:938:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPH:938:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPH:938:EDES NPP MS")
  field(INPB, "XCOR:SPH:938:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPH:346:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPH:346:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPH:346:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPH:346:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPH:346:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPH:346:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPH:346:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPH:346:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPH:346:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPH:346:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPH:346:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPH:346:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPH:346:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPH:346:EDES.PROC PP")
    field(LNK2, "YCOR:SPH:346:EACT.PROC PP")
    field(LNK3, "YCOR:SPH:346:EERR.DISA PP")
    field(LNK4, "YCOR:SPH:346:ECON.PROC PP")
    field(LNK5, "YCOR:SPH:346:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPH:346:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPH:346:BLEM.PROC PP")
    field(LNK8, "YCOR:SPH:346:BMOD.PROC PP")
    field(LNK9, "YCOR:SPH:346:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPH:346:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPH:346:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPH:346:BMAX")
  field(DOL2, "YCOR:SPH:346:BMAX")
  field(DOL3, "YCOR:SPH:346:BMAX")
  field(DOL4, "YCOR:SPH:346:BMIN")
  field(DOL5, "YCOR:SPH:346:BMIN")
  field(DOL6, "YCOR:SPH:346:BMIN")
  field(LNK1, "YCOR:SPH:346:BMAGX.HOPR")
  field(LNK2, "YCOR:SPH:346:BMAGY.HOPR")
  field(LNK3, "YCOR:SPH:346:BLEM.HOPR")
  field(LNK4, "YCOR:SPH:346:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPH:346:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPH:346:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:346:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:346:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPH:346:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPH:346:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPH:346:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:346:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:346:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:346:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:346:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:346:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPH:346:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPH:346:EDES NPP MS")
  field(INPB, "YCOR:SPH:346:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPH:447:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPH:447:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPH:447:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPH:447:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPH:447:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPH:447:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPH:447:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPH:447:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPH:447:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPH:447:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPH:447:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPH:447:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPH:447:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPH:447:EDES.PROC PP")
    field(LNK2, "YCOR:SPH:447:EACT.PROC PP")
    field(LNK3, "YCOR:SPH:447:EERR.DISA PP")
    field(LNK4, "YCOR:SPH:447:ECON.PROC PP")
    field(LNK5, "YCOR:SPH:447:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPH:447:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPH:447:BLEM.PROC PP")
    field(LNK8, "YCOR:SPH:447:BMOD.PROC PP")
    field(LNK9, "YCOR:SPH:447:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPH:447:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPH:447:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPH:447:BMAX")
  field(DOL2, "YCOR:SPH:447:BMAX")
  field(DOL3, "YCOR:SPH:447:BMAX")
  field(DOL4, "YCOR:SPH:447:BMIN")
  field(DOL5, "YCOR:SPH:447:BMIN")
  field(DOL6, "YCOR:SPH:447:BMIN")
  field(LNK1, "YCOR:SPH:447:BMAGX.HOPR")
  field(LNK2, "YCOR:SPH:447:BMAGY.HOPR")
  field(LNK3, "YCOR:SPH:447:BLEM.HOPR")
  field(LNK4, "YCOR:SPH:447:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPH:447:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPH:447:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:447:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:447:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPH:447:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPH:447:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPH:447:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:447:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:447:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:447:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:447:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:447:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPH:447:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPH:447:EDES NPP MS")
  field(INPB, "YCOR:SPH:447:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPH:597:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPH:597:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPH:597:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPH:597:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPH:597:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPH:597:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPH:597:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPH:597:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPH:597:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPH:597:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPH:597:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPH:597:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPH:597:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPH:597:EDES.PROC PP")
    field(LNK2, "YCOR:SPH:597:EACT.PROC PP")
    field(LNK3, "YCOR:SPH:597:EERR.DISA PP")
    field(LNK4, "YCOR:SPH:597:ECON.PROC PP")
    field(LNK5, "YCOR:SPH:597:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPH:597:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPH:597:BLEM.PROC PP")
    field(LNK8, "YCOR:SPH:597:BMOD.PROC PP")
    field(LNK9, "YCOR:SPH:597:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPH:597:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPH:597:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPH:597:BMAX")
  field(DOL2, "YCOR:SPH:597:BMAX")
  field(DOL3, "YCOR:SPH:597:BMAX")
  field(DOL4, "YCOR:SPH:597:BMIN")
  field(DOL5, "YCOR:SPH:597:BMIN")
  field(DOL6, "YCOR:SPH:597:BMIN")
  field(LNK1, "YCOR:SPH:597:BMAGX.HOPR")
  field(LNK2, "YCOR:SPH:597:BMAGY.HOPR")
  field(LNK3, "YCOR:SPH:597:BLEM.HOPR")
  field(LNK4, "YCOR:SPH:597:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPH:597:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPH:597:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:597:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:597:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPH:597:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPH:597:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPH:597:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:597:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:597:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:597:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:597:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:597:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPH:597:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPH:597:EDES NPP MS")
  field(INPB, "YCOR:SPH:597:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPH:757:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPH:757:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPH:757:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPH:757:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPH:757:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPH:757:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPH:757:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPH:757:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPH:757:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPH:757:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPH:757:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPH:757:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPH:757:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPH:757:EDES.PROC PP")
    field(LNK2, "YCOR:SPH:757:EACT.PROC PP")
    field(LNK3, "YCOR:SPH:757:EERR.DISA PP")
    field(LNK4, "YCOR:SPH:757:ECON.PROC PP")
    field(LNK5, "YCOR:SPH:757:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPH:757:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPH:757:BLEM.PROC PP")
    field(LNK8, "YCOR:SPH:757:BMOD.PROC PP")
    field(LNK9, "YCOR:SPH:757:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPH:757:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPH:757:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPH:757:BMAX")
  field(DOL2, "YCOR:SPH:757:BMAX")
  field(DOL3, "YCOR:SPH:757:BMAX")
  field(DOL4, "YCOR:SPH:757:BMIN")
  field(DOL5, "YCOR:SPH:757:BMIN")
  field(DOL6, "YCOR:SPH:757:BMIN")
  field(LNK1, "YCOR:SPH:757:BMAGX.HOPR")
  field(LNK2, "YCOR:SPH:757:BMAGY.HOPR")
  field(LNK3, "YCOR:SPH:757:BLEM.HOPR")
  field(LNK4, "YCOR:SPH:757:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPH:757:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPH:757:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:757:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:757:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPH:757:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPH:757:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPH:757:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:757:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:757:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:757:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:757:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:757:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPH:757:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPH:757:EDES NPP MS")
  field(INPB, "YCOR:SPH:757:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPH:917:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPH:917:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPH:917:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPH:917:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPH:917:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPH:917:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPH:917:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPH:917:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPH:917:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPH:917:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPH:917:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPH:917:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPH:917:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPH:917:EDES.PROC PP")
    field(LNK2, "YCOR:SPH:917:EACT.PROC PP")
    field(LNK3, "YCOR:SPH:917:EERR.DISA PP")
    field(LNK4, "YCOR:SPH:917:ECON.PROC PP")
    field(LNK5, "YCOR:SPH:917:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPH:917:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPH:917:BLEM.PROC PP")
    field(LNK8, "YCOR:SPH:917:BMOD.PROC PP")
    field(LNK9, "YCOR:SPH:917:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPH:917:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPH:917:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPH:917:BMAX")
  field(DOL2, "YCOR:SPH:917:BMAX")
  field(DOL3, "YCOR:SPH:917:BMAX")
  field(DOL4, "YCOR:SPH:917:BMIN")
  field(DOL5, "YCOR:SPH:917:BMIN")
  field(DOL6, "YCOR:SPH:917:BMIN")
  field(LNK1, "YCOR:SPH:917:BMAGX.HOPR")
  field(LNK2, "YCOR:SPH:917:BMAGY.HOPR")
  field(LNK3, "YCOR:SPH:917:BLEM.HOPR")
  field(LNK4, "YCOR:SPH:917:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPH:917:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPH:917:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:917:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPH:917:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPH:917:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPH:917:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPH:917:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:917:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:917:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:917:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPH:917:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPH:917:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPH:917:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPH:917:EDES NPP MS")
  field(INPB, "YCOR:SPH:917:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:SPS:385:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "KICK:SPS:385:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:SPS:385:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:SPS:385:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:SPS:385:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:SPS:385:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:SPS:385:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:SPS:385:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:SPS:385:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:SPS:385:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:SPS:385:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:SPS:385:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:SPS:385:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:SPS:385:EDES.PROC PP")
    field(LNK2, "KICK:SPS:385:EACT.PROC PP")
    field(LNK3, "KICK:SPS:385:EERR.DISA PP")
    field(LNK4, "KICK:SPS:385:ECON.PROC PP")
    field(LNK5, "KICK:SPS:385:BMAGX.PROC PP")
    field(LNK6, "KICK:SPS:385:BMAGY.PROC PP")
    field(LNK7, "KICK:SPS:385:BLEM.PROC PP")
    field(LNK8, "KICK:SPS:385:BMOD.PROC PP")
    field(LNK9, "KICK:SPS:385:EDESSAVE.PROC PP")
    field(LNKA, "KICK:SPS:385:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:SPS:385:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:SPS:385:BMAX")
  field(DOL2, "KICK:SPS:385:BMAX")
  field(DOL3, "KICK:SPS:385:BMAX")
  field(DOL4, "KICK:SPS:385:BMIN")
  field(DOL5, "KICK:SPS:385:BMIN")
  field(DOL6, "KICK:SPS:385:BMIN")
  field(LNK1, "KICK:SPS:385:BMAGX.HOPR")
  field(LNK2, "KICK:SPS:385:BMAGY.HOPR")
  field(LNK3, "KICK:SPS:385:BLEM.HOPR")
  field(LNK4, "KICK:SPS:385:BMAGX.LOPR PP")
  field(LNK5, "KICK:SPS:385:BMAGY.LOPR PP")
  field(LNK6, "KICK:SPS:385:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:SPS:385:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:SPS:385:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:SPS:385:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:SPS:385:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:SPS:385:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:385:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:385:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:SPS:385:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:385:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:SPS:385:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:SPS:385:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:SPS:385:EDES NPP MS")
  field(INPB, "KICK:SPS:385:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPS:530:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BEND:SPS:530:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPS:530:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPS:530:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPS:530:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPS:530:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPS:530:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPS:530:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPS:530:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPS:530:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPS:530:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPS:530:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPS:530:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPS:530:EDES.PROC PP")
    field(LNK2, "BEND:SPS:530:EACT.PROC PP")
    field(LNK3, "BEND:SPS:530:EERR.DISA PP")
    field(LNK4, "BEND:SPS:530:ECON.PROC PP")
    field(LNK5, "BEND:SPS:530:BMAGX.PROC PP")
    field(LNK6, "BEND:SPS:530:BMAGY.PROC PP")
    field(LNK7, "BEND:SPS:530:BLEM.PROC PP")
    field(LNK8, "BEND:SPS:530:BMOD.PROC PP")
    field(LNK9, "BEND:SPS:530:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPS:530:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPS:530:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPS:530:BMAX")
  field(DOL2, "BEND:SPS:530:BMAX")
  field(DOL3, "BEND:SPS:530:BMAX")
  field(DOL4, "BEND:SPS:530:BMIN")
  field(DOL5, "BEND:SPS:530:BMIN")
  field(DOL6, "BEND:SPS:530:BMIN")
  field(LNK1, "BEND:SPS:530:BMAGX.HOPR")
  field(LNK2, "BEND:SPS:530:BMAGY.HOPR")
  field(LNK3, "BEND:SPS:530:BLEM.HOPR")
  field(LNK4, "BEND:SPS:530:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPS:530:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPS:530:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:530:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:530:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPS:530:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPS:530:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPS:530:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:530:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:530:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPS:530:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:530:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPS:530:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPS:530:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPS:530:EDES NPP MS")
  field(INPB, "BEND:SPS:530:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPS:560:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BEND:SPS:560:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPS:560:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPS:560:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPS:560:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPS:560:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPS:560:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPS:560:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPS:560:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPS:560:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPS:560:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPS:560:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPS:560:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPS:560:EDES.PROC PP")
    field(LNK2, "BEND:SPS:560:EACT.PROC PP")
    field(LNK3, "BEND:SPS:560:EERR.DISA PP")
    field(LNK4, "BEND:SPS:560:ECON.PROC PP")
    field(LNK5, "BEND:SPS:560:BMAGX.PROC PP")
    field(LNK6, "BEND:SPS:560:BMAGY.PROC PP")
    field(LNK7, "BEND:SPS:560:BLEM.PROC PP")
    field(LNK8, "BEND:SPS:560:BMOD.PROC PP")
    field(LNK9, "BEND:SPS:560:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPS:560:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPS:560:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPS:560:BMAX")
  field(DOL2, "BEND:SPS:560:BMAX")
  field(DOL3, "BEND:SPS:560:BMAX")
  field(DOL4, "BEND:SPS:560:BMIN")
  field(DOL5, "BEND:SPS:560:BMIN")
  field(DOL6, "BEND:SPS:560:BMIN")
  field(LNK1, "BEND:SPS:560:BMAGX.HOPR")
  field(LNK2, "BEND:SPS:560:BMAGY.HOPR")
  field(LNK3, "BEND:SPS:560:BLEM.HOPR")
  field(LNK4, "BEND:SPS:560:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPS:560:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPS:560:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:560:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:560:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPS:560:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPS:560:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPS:560:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:560:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:560:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPS:560:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:560:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPS:560:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPS:560:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPS:560:EDES NPP MS")
  field(INPB, "BEND:SPS:560:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPS:800:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BEND:SPS:800:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPS:800:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPS:800:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPS:800:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPS:800:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPS:800:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPS:800:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPS:800:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPS:800:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPS:800:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPS:800:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPS:800:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPS:800:EDES.PROC PP")
    field(LNK2, "BEND:SPS:800:EACT.PROC PP")
    field(LNK3, "BEND:SPS:800:EERR.DISA PP")
    field(LNK4, "BEND:SPS:800:ECON.PROC PP")
    field(LNK5, "BEND:SPS:800:BMAGX.PROC PP")
    field(LNK6, "BEND:SPS:800:BMAGY.PROC PP")
    field(LNK7, "BEND:SPS:800:BLEM.PROC PP")
    field(LNK8, "BEND:SPS:800:BMOD.PROC PP")
    field(LNK9, "BEND:SPS:800:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPS:800:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPS:800:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPS:800:BMAX")
  field(DOL2, "BEND:SPS:800:BMAX")
  field(DOL3, "BEND:SPS:800:BMAX")
  field(DOL4, "BEND:SPS:800:BMIN")
  field(DOL5, "BEND:SPS:800:BMIN")
  field(DOL6, "BEND:SPS:800:BMIN")
  field(LNK1, "BEND:SPS:800:BMAGX.HOPR")
  field(LNK2, "BEND:SPS:800:BMAGY.HOPR")
  field(LNK3, "BEND:SPS:800:BLEM.HOPR")
  field(LNK4, "BEND:SPS:800:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPS:800:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPS:800:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:800:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:800:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPS:800:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPS:800:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPS:800:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:800:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:800:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPS:800:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:800:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPS:800:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPS:800:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPS:800:EDES NPP MS")
  field(INPB, "BEND:SPS:800:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SPS:470:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BTRM:SPS:470:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SPS:470:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SPS:470:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SPS:470:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SPS:470:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SPS:470:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SPS:470:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SPS:470:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SPS:470:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SPS:470:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SPS:470:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SPS:470:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SPS:470:EDES.PROC PP")
    field(LNK2, "BTRM:SPS:470:EACT.PROC PP")
    field(LNK3, "BTRM:SPS:470:EERR.DISA PP")
    field(LNK4, "BTRM:SPS:470:ECON.PROC PP")
    field(LNK5, "BTRM:SPS:470:BMAGX.PROC PP")
    field(LNK6, "BTRM:SPS:470:BMAGY.PROC PP")
    field(LNK7, "BTRM:SPS:470:BLEM.PROC PP")
    field(LNK8, "BTRM:SPS:470:BMOD.PROC PP")
    field(LNK9, "BTRM:SPS:470:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SPS:470:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SPS:470:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SPS:470:BMAX")
  field(DOL2, "BTRM:SPS:470:BMAX")
  field(DOL3, "BTRM:SPS:470:BMAX")
  field(DOL4, "BTRM:SPS:470:BMIN")
  field(DOL5, "BTRM:SPS:470:BMIN")
  field(DOL6, "BTRM:SPS:470:BMIN")
  field(LNK1, "BTRM:SPS:470:BMAGX.HOPR")
  field(LNK2, "BTRM:SPS:470:BMAGY.HOPR")
  field(LNK3, "BTRM:SPS:470:BLEM.HOPR")
  field(LNK4, "BTRM:SPS:470:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SPS:470:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SPS:470:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SPS:470:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SPS:470:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SPS:470:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SPS:470:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SPS:470:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:470:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:470:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPS:470:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:470:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPS:470:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SPS:470:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SPS:470:EDES NPP MS")
  field(INPB, "BTRM:SPS:470:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SPS:610:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BTRM:SPS:610:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SPS:610:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SPS:610:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SPS:610:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SPS:610:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SPS:610:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SPS:610:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SPS:610:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SPS:610:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SPS:610:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SPS:610:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SPS:610:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SPS:610:EDES.PROC PP")
    field(LNK2, "BTRM:SPS:610:EACT.PROC PP")
    field(LNK3, "BTRM:SPS:610:EERR.DISA PP")
    field(LNK4, "BTRM:SPS:610:ECON.PROC PP")
    field(LNK5, "BTRM:SPS:610:BMAGX.PROC PP")
    field(LNK6, "BTRM:SPS:610:BMAGY.PROC PP")
    field(LNK7, "BTRM:SPS:610:BLEM.PROC PP")
    field(LNK8, "BTRM:SPS:610:BMOD.PROC PP")
    field(LNK9, "BTRM:SPS:610:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SPS:610:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SPS:610:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SPS:610:BMAX")
  field(DOL2, "BTRM:SPS:610:BMAX")
  field(DOL3, "BTRM:SPS:610:BMAX")
  field(DOL4, "BTRM:SPS:610:BMIN")
  field(DOL5, "BTRM:SPS:610:BMIN")
  field(DOL6, "BTRM:SPS:610:BMIN")
  field(LNK1, "BTRM:SPS:610:BMAGX.HOPR")
  field(LNK2, "BTRM:SPS:610:BMAGY.HOPR")
  field(LNK3, "BTRM:SPS:610:BLEM.HOPR")
  field(LNK4, "BTRM:SPS:610:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SPS:610:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SPS:610:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SPS:610:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SPS:610:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SPS:610:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SPS:610:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SPS:610:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:610:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:610:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPS:610:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:610:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPS:610:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SPS:610:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SPS:610:EDES NPP MS")
  field(INPB, "BTRM:SPS:610:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SPS:950:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BTRM:SPS:950:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SPS:950:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SPS:950:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SPS:950:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SPS:950:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SPS:950:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SPS:950:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SPS:950:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SPS:950:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SPS:950:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SPS:950:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SPS:950:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SPS:950:EDES.PROC PP")
    field(LNK2, "BTRM:SPS:950:EACT.PROC PP")
    field(LNK3, "BTRM:SPS:950:EERR.DISA PP")
    field(LNK4, "BTRM:SPS:950:ECON.PROC PP")
    field(LNK5, "BTRM:SPS:950:BMAGX.PROC PP")
    field(LNK6, "BTRM:SPS:950:BMAGY.PROC PP")
    field(LNK7, "BTRM:SPS:950:BLEM.PROC PP")
    field(LNK8, "BTRM:SPS:950:BMOD.PROC PP")
    field(LNK9, "BTRM:SPS:950:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SPS:950:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SPS:950:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SPS:950:BMAX")
  field(DOL2, "BTRM:SPS:950:BMAX")
  field(DOL3, "BTRM:SPS:950:BMAX")
  field(DOL4, "BTRM:SPS:950:BMIN")
  field(DOL5, "BTRM:SPS:950:BMIN")
  field(DOL6, "BTRM:SPS:950:BMIN")
  field(LNK1, "BTRM:SPS:950:BMAGX.HOPR")
  field(LNK2, "BTRM:SPS:950:BMAGY.HOPR")
  field(LNK3, "BTRM:SPS:950:BLEM.HOPR")
  field(LNK4, "BTRM:SPS:950:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SPS:950:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SPS:950:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SPS:950:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SPS:950:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SPS:950:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SPS:950:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SPS:950:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:950:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:950:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPS:950:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPS:950:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPS:950:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SPS:950:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SPS:950:EDES NPP MS")
  field(INPB, "BTRM:SPS:950:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:570:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:570:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:570:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:570:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:570:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:570:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:570:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:570:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:570:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:570:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:570:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:570:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:570:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:570:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:570:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:570:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:570:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:570:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:570:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:570:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:570:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:570:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:570:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:570:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:570:BMAX")
  field(DOL2, "QUAD:SPS:570:BMAX")
  field(DOL3, "QUAD:SPS:570:BMAX")
  field(DOL4, "QUAD:SPS:570:BMIN")
  field(DOL5, "QUAD:SPS:570:BMIN")
  field(DOL6, "QUAD:SPS:570:BMIN")
  field(LNK1, "QUAD:SPS:570:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:570:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:570:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:570:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:570:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:570:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:570:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:570:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:570:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:570:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:570:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:570:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:570:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:570:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:570:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:570:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:570:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:570:EDES NPP MS")
  field(INPB, "QUAD:SPS:570:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:580:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:580:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:580:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:580:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:580:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:580:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:580:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:580:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:580:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:580:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:580:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:580:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:580:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:580:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:580:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:580:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:580:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:580:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:580:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:580:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:580:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:580:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:580:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:580:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:580:BMAX")
  field(DOL2, "QUAD:SPS:580:BMAX")
  field(DOL3, "QUAD:SPS:580:BMAX")
  field(DOL4, "QUAD:SPS:580:BMIN")
  field(DOL5, "QUAD:SPS:580:BMIN")
  field(DOL6, "QUAD:SPS:580:BMIN")
  field(LNK1, "QUAD:SPS:580:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:580:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:580:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:580:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:580:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:580:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:580:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:580:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:580:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:580:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:580:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:580:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:580:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:580:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:580:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:580:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:580:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:580:EDES NPP MS")
  field(INPB, "QUAD:SPS:580:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:640:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:640:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:640:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:640:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:640:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:640:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:640:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:640:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:640:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:640:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:640:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:640:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:640:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:640:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:640:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:640:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:640:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:640:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:640:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:640:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:640:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:640:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:640:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:640:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:640:BMAX")
  field(DOL2, "QUAD:SPS:640:BMAX")
  field(DOL3, "QUAD:SPS:640:BMAX")
  field(DOL4, "QUAD:SPS:640:BMIN")
  field(DOL5, "QUAD:SPS:640:BMIN")
  field(DOL6, "QUAD:SPS:640:BMIN")
  field(LNK1, "QUAD:SPS:640:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:640:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:640:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:640:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:640:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:640:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:640:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:640:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:640:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:640:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:640:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:640:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:640:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:640:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:640:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:640:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:640:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:640:EDES NPP MS")
  field(INPB, "QUAD:SPS:640:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:650:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:650:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:650:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:650:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:650:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:650:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:650:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:650:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:650:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:650:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:650:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:650:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:650:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:650:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:650:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:650:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:650:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:650:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:650:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:650:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:650:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:650:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:650:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:650:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:650:BMAX")
  field(DOL2, "QUAD:SPS:650:BMAX")
  field(DOL3, "QUAD:SPS:650:BMAX")
  field(DOL4, "QUAD:SPS:650:BMIN")
  field(DOL5, "QUAD:SPS:650:BMIN")
  field(DOL6, "QUAD:SPS:650:BMIN")
  field(LNK1, "QUAD:SPS:650:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:650:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:650:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:650:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:650:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:650:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:650:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:650:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:650:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:650:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:650:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:650:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:650:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:650:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:650:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:650:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:650:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:650:EDES NPP MS")
  field(INPB, "QUAD:SPS:650:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:710:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:710:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:710:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:710:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:710:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:710:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:710:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:710:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:710:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:710:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:710:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:710:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:710:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:710:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:710:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:710:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:710:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:710:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:710:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:710:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:710:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:710:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:710:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:710:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:710:BMAX")
  field(DOL2, "QUAD:SPS:710:BMAX")
  field(DOL3, "QUAD:SPS:710:BMAX")
  field(DOL4, "QUAD:SPS:710:BMIN")
  field(DOL5, "QUAD:SPS:710:BMIN")
  field(DOL6, "QUAD:SPS:710:BMIN")
  field(LNK1, "QUAD:SPS:710:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:710:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:710:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:710:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:710:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:710:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:710:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:710:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:710:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:710:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:710:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:710:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:710:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:710:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:710:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPS:710:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:710:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:710:EDES NPP MS")
  field(INPB, "QUAD:SPS:710:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPS:578:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPS:578:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPS:578:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPS:578:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPS:578:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPS:578:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPS:578:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPS:578:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPS:578:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPS:578:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPS:578:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPS:578:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPS:578:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPS:578:EDES.PROC PP")
    field(LNK2, "XCOR:SPS:578:EACT.PROC PP")
    field(LNK3, "XCOR:SPS:578:EERR.DISA PP")
    field(LNK4, "XCOR:SPS:578:ECON.PROC PP")
    field(LNK5, "XCOR:SPS:578:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPS:578:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPS:578:BLEM.PROC PP")
    field(LNK8, "XCOR:SPS:578:BMOD.PROC PP")
    field(LNK9, "XCOR:SPS:578:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPS:578:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPS:578:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPS:578:BMAX")
  field(DOL2, "XCOR:SPS:578:BMAX")
  field(DOL3, "XCOR:SPS:578:BMAX")
  field(DOL4, "XCOR:SPS:578:BMIN")
  field(DOL5, "XCOR:SPS:578:BMIN")
  field(DOL6, "XCOR:SPS:578:BMIN")
  field(LNK1, "XCOR:SPS:578:BMAGX.HOPR")
  field(LNK2, "XCOR:SPS:578:BMAGY.HOPR")
  field(LNK3, "XCOR:SPS:578:BLEM.HOPR")
  field(LNK4, "XCOR:SPS:578:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPS:578:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPS:578:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:578:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:578:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPS:578:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPS:578:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPS:578:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:578:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:578:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:578:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:578:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:578:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPS:578:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPS:578:EDES NPP MS")
  field(INPB, "XCOR:SPS:578:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPS:634:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPS:634:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPS:634:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPS:634:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPS:634:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPS:634:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPS:634:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPS:634:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPS:634:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPS:634:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPS:634:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPS:634:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPS:634:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPS:634:EDES.PROC PP")
    field(LNK2, "XCOR:SPS:634:EACT.PROC PP")
    field(LNK3, "XCOR:SPS:634:EERR.DISA PP")
    field(LNK4, "XCOR:SPS:634:ECON.PROC PP")
    field(LNK5, "XCOR:SPS:634:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPS:634:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPS:634:BLEM.PROC PP")
    field(LNK8, "XCOR:SPS:634:BMOD.PROC PP")
    field(LNK9, "XCOR:SPS:634:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPS:634:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPS:634:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPS:634:BMAX")
  field(DOL2, "XCOR:SPS:634:BMAX")
  field(DOL3, "XCOR:SPS:634:BMAX")
  field(DOL4, "XCOR:SPS:634:BMIN")
  field(DOL5, "XCOR:SPS:634:BMIN")
  field(DOL6, "XCOR:SPS:634:BMIN")
  field(LNK1, "XCOR:SPS:634:BMAGX.HOPR")
  field(LNK2, "XCOR:SPS:634:BMAGY.HOPR")
  field(LNK3, "XCOR:SPS:634:BLEM.HOPR")
  field(LNK4, "XCOR:SPS:634:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPS:634:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPS:634:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:634:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:634:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPS:634:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPS:634:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPS:634:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:634:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:634:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:634:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:634:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:634:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPS:634:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPS:634:EDES NPP MS")
  field(INPB, "XCOR:SPS:634:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPS:706:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPS:706:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPS:706:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPS:706:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPS:706:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPS:706:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPS:706:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPS:706:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPS:706:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPS:706:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPS:706:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPS:706:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPS:706:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPS:706:EDES.PROC PP")
    field(LNK2, "XCOR:SPS:706:EACT.PROC PP")
    field(LNK3, "XCOR:SPS:706:EERR.DISA PP")
    field(LNK4, "XCOR:SPS:706:ECON.PROC PP")
    field(LNK5, "XCOR:SPS:706:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPS:706:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPS:706:BLEM.PROC PP")
    field(LNK8, "XCOR:SPS:706:BMOD.PROC PP")
    field(LNK9, "XCOR:SPS:706:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPS:706:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPS:706:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPS:706:BMAX")
  field(DOL2, "XCOR:SPS:706:BMAX")
  field(DOL3, "XCOR:SPS:706:BMAX")
  field(DOL4, "XCOR:SPS:706:BMIN")
  field(DOL5, "XCOR:SPS:706:BMIN")
  field(DOL6, "XCOR:SPS:706:BMIN")
  field(LNK1, "XCOR:SPS:706:BMAGX.HOPR")
  field(LNK2, "XCOR:SPS:706:BMAGY.HOPR")
  field(LNK3, "XCOR:SPS:706:BLEM.HOPR")
  field(LNK4, "XCOR:SPS:706:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPS:706:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPS:706:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:706:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:706:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPS:706:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPS:706:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPS:706:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:706:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:706:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:706:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:706:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:706:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPS:706:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPS:706:EDES NPP MS")
  field(INPB, "XCOR:SPS:706:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPS:776:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPS:776:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPS:776:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPS:776:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPS:776:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPS:776:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPS:776:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPS:776:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPS:776:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPS:776:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPS:776:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPS:776:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPS:776:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPS:776:EDES.PROC PP")
    field(LNK2, "XCOR:SPS:776:EACT.PROC PP")
    field(LNK3, "XCOR:SPS:776:EERR.DISA PP")
    field(LNK4, "XCOR:SPS:776:ECON.PROC PP")
    field(LNK5, "XCOR:SPS:776:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPS:776:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPS:776:BLEM.PROC PP")
    field(LNK8, "XCOR:SPS:776:BMOD.PROC PP")
    field(LNK9, "XCOR:SPS:776:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPS:776:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPS:776:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPS:776:BMAX")
  field(DOL2, "XCOR:SPS:776:BMAX")
  field(DOL3, "XCOR:SPS:776:BMAX")
  field(DOL4, "XCOR:SPS:776:BMIN")
  field(DOL5, "XCOR:SPS:776:BMIN")
  field(DOL6, "XCOR:SPS:776:BMIN")
  field(LNK1, "XCOR:SPS:776:BMAGX.HOPR")
  field(LNK2, "XCOR:SPS:776:BMAGY.HOPR")
  field(LNK3, "XCOR:SPS:776:BLEM.HOPR")
  field(LNK4, "XCOR:SPS:776:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPS:776:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPS:776:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:776:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:776:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPS:776:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPS:776:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPS:776:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:776:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:776:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:776:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:776:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:776:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPS:776:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPS:776:EDES NPP MS")
  field(INPB, "XCOR:SPS:776:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPS:836:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPS:836:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPS:836:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPS:836:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPS:836:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPS:836:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPS:836:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPS:836:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPS:836:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPS:836:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPS:836:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPS:836:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPS:836:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPS:836:EDES.PROC PP")
    field(LNK2, "XCOR:SPS:836:EACT.PROC PP")
    field(LNK3, "XCOR:SPS:836:EERR.DISA PP")
    field(LNK4, "XCOR:SPS:836:ECON.PROC PP")
    field(LNK5, "XCOR:SPS:836:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPS:836:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPS:836:BLEM.PROC PP")
    field(LNK8, "XCOR:SPS:836:BMOD.PROC PP")
    field(LNK9, "XCOR:SPS:836:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPS:836:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPS:836:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPS:836:BMAX")
  field(DOL2, "XCOR:SPS:836:BMAX")
  field(DOL3, "XCOR:SPS:836:BMAX")
  field(DOL4, "XCOR:SPS:836:BMIN")
  field(DOL5, "XCOR:SPS:836:BMIN")
  field(DOL6, "XCOR:SPS:836:BMIN")
  field(LNK1, "XCOR:SPS:836:BMAGX.HOPR")
  field(LNK2, "XCOR:SPS:836:BMAGY.HOPR")
  field(LNK3, "XCOR:SPS:836:BLEM.HOPR")
  field(LNK4, "XCOR:SPS:836:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPS:836:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPS:836:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:836:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPS:836:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPS:836:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPS:836:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPS:836:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:836:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:836:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:836:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPS:836:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPS:836:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPS:836:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPS:836:EDES NPP MS")
  field(INPB, "XCOR:SPS:836:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPS:587:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPS:587:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPS:587:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPS:587:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPS:587:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPS:587:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPS:587:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPS:587:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPS:587:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPS:587:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPS:587:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPS:587:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPS:587:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPS:587:EDES.PROC PP")
    field(LNK2, "YCOR:SPS:587:EACT.PROC PP")
    field(LNK3, "YCOR:SPS:587:EERR.DISA PP")
    field(LNK4, "YCOR:SPS:587:ECON.PROC PP")
    field(LNK5, "YCOR:SPS:587:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPS:587:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPS:587:BLEM.PROC PP")
    field(LNK8, "YCOR:SPS:587:BMOD.PROC PP")
    field(LNK9, "YCOR:SPS:587:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPS:587:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPS:587:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPS:587:BMAX")
  field(DOL2, "YCOR:SPS:587:BMAX")
  field(DOL3, "YCOR:SPS:587:BMAX")
  field(DOL4, "YCOR:SPS:587:BMIN")
  field(DOL5, "YCOR:SPS:587:BMIN")
  field(DOL6, "YCOR:SPS:587:BMIN")
  field(LNK1, "YCOR:SPS:587:BMAGX.HOPR")
  field(LNK2, "YCOR:SPS:587:BMAGY.HOPR")
  field(LNK3, "YCOR:SPS:587:BLEM.HOPR")
  field(LNK4, "YCOR:SPS:587:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPS:587:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPS:587:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:587:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:587:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPS:587:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPS:587:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPS:587:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:587:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:587:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:587:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:587:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:587:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPS:587:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPS:587:EDES NPP MS")
  field(INPB, "YCOR:SPS:587:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPS:643:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPS:643:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPS:643:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPS:643:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPS:643:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPS:643:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPS:643:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPS:643:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPS:643:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPS:643:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPS:643:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPS:643:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPS:643:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPS:643:EDES.PROC PP")
    field(LNK2, "YCOR:SPS:643:EACT.PROC PP")
    field(LNK3, "YCOR:SPS:643:EERR.DISA PP")
    field(LNK4, "YCOR:SPS:643:ECON.PROC PP")
    field(LNK5, "YCOR:SPS:643:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPS:643:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPS:643:BLEM.PROC PP")
    field(LNK8, "YCOR:SPS:643:BMOD.PROC PP")
    field(LNK9, "YCOR:SPS:643:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPS:643:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPS:643:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPS:643:BMAX")
  field(DOL2, "YCOR:SPS:643:BMAX")
  field(DOL3, "YCOR:SPS:643:BMAX")
  field(DOL4, "YCOR:SPS:643:BMIN")
  field(DOL5, "YCOR:SPS:643:BMIN")
  field(DOL6, "YCOR:SPS:643:BMIN")
  field(LNK1, "YCOR:SPS:643:BMAGX.HOPR")
  field(LNK2, "YCOR:SPS:643:BMAGY.HOPR")
  field(LNK3, "YCOR:SPS:643:BLEM.HOPR")
  field(LNK4, "YCOR:SPS:643:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPS:643:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPS:643:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:643:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:643:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPS:643:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPS:643:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPS:643:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:643:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:643:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:643:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:643:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:643:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPS:643:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPS:643:EDES NPP MS")
  field(INPB, "YCOR:SPS:643:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPS:767:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPS:767:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPS:767:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPS:767:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPS:767:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPS:767:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPS:767:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPS:767:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPS:767:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPS:767:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPS:767:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPS:767:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPS:767:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPS:767:EDES.PROC PP")
    field(LNK2, "YCOR:SPS:767:EACT.PROC PP")
    field(LNK3, "YCOR:SPS:767:EERR.DISA PP")
    field(LNK4, "YCOR:SPS:767:ECON.PROC PP")
    field(LNK5, "YCOR:SPS:767:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPS:767:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPS:767:BLEM.PROC PP")
    field(LNK8, "YCOR:SPS:767:BMOD.PROC PP")
    field(LNK9, "YCOR:SPS:767:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPS:767:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPS:767:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPS:767:BMAX")
  field(DOL2, "YCOR:SPS:767:BMAX")
  field(DOL3, "YCOR:SPS:767:BMAX")
  field(DOL4, "YCOR:SPS:767:BMIN")
  field(DOL5, "YCOR:SPS:767:BMIN")
  field(DOL6, "YCOR:SPS:767:BMIN")
  field(LNK1, "YCOR:SPS:767:BMAGX.HOPR")
  field(LNK2, "YCOR:SPS:767:BMAGY.HOPR")
  field(LNK3, "YCOR:SPS:767:BLEM.HOPR")
  field(LNK4, "YCOR:SPS:767:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPS:767:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPS:767:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:767:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:767:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPS:767:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPS:767:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPS:767:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:767:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:767:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:767:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:767:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:767:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPS:767:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPS:767:EDES NPP MS")
  field(INPB, "YCOR:SPS:767:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPS:827:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPS:827:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPS:827:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPS:827:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPS:827:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPS:827:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPS:827:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPS:827:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPS:827:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPS:827:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPS:827:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPS:827:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPS:827:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPS:827:EDES.PROC PP")
    field(LNK2, "YCOR:SPS:827:EACT.PROC PP")
    field(LNK3, "YCOR:SPS:827:EERR.DISA PP")
    field(LNK4, "YCOR:SPS:827:ECON.PROC PP")
    field(LNK5, "YCOR:SPS:827:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPS:827:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPS:827:BLEM.PROC PP")
    field(LNK8, "YCOR:SPS:827:BMOD.PROC PP")
    field(LNK9, "YCOR:SPS:827:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPS:827:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPS:827:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPS:827:BMAX")
  field(DOL2, "YCOR:SPS:827:BMAX")
  field(DOL3, "YCOR:SPS:827:BMAX")
  field(DOL4, "YCOR:SPS:827:BMIN")
  field(DOL5, "YCOR:SPS:827:BMIN")
  field(DOL6, "YCOR:SPS:827:BMIN")
  field(LNK1, "YCOR:SPS:827:BMAGX.HOPR")
  field(LNK2, "YCOR:SPS:827:BMAGY.HOPR")
  field(LNK3, "YCOR:SPS:827:BLEM.HOPR")
  field(LNK4, "YCOR:SPS:827:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPS:827:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPS:827:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:827:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPS:827:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPS:827:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPS:827:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPS:827:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:827:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:827:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:827:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPS:827:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPS:827:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPS:827:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPS:827:EDES NPP MS")
  field(INPB, "YCOR:SPS:827:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPD:960:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "BEND:SPD:960:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPD:960:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPD:960:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPD:960:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPD:960:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPD:960:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPD:960:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPD:960:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPD:960:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPD:960:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPD:960:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPD:960:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPD:960:EDES.PROC PP")
    field(LNK2, "BEND:SPD:960:EACT.PROC PP")
    field(LNK3, "BEND:SPD:960:EERR.DISA PP")
    field(LNK4, "BEND:SPD:960:ECON.PROC PP")
    field(LNK5, "BEND:SPD:960:BMAGX.PROC PP")
    field(LNK6, "BEND:SPD:960:BMAGY.PROC PP")
    field(LNK7, "BEND:SPD:960:BLEM.PROC PP")
    field(LNK8, "BEND:SPD:960:BMOD.PROC PP")
    field(LNK9, "BEND:SPD:960:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPD:960:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPD:960:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPD:960:BMAX")
  field(DOL2, "BEND:SPD:960:BMAX")
  field(DOL3, "BEND:SPD:960:BMAX")
  field(DOL4, "BEND:SPD:960:BMIN")
  field(DOL5, "BEND:SPD:960:BMIN")
  field(DOL6, "BEND:SPD:960:BMIN")
  field(LNK1, "BEND:SPD:960:BMAGX.HOPR")
  field(LNK2, "BEND:SPD:960:BMAGY.HOPR")
  field(LNK3, "BEND:SPD:960:BLEM.HOPR")
  field(LNK4, "BEND:SPD:960:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPD:960:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPD:960:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPD:960:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPD:960:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPD:960:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPD:960:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPD:960:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPD:960:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPD:960:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPD:960:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPD:960:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:SPD:960:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPD:960:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPD:960:EDES NPP MS")
  field(INPB, "BEND:SPD:960:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BTRM:SPD:719:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "BTRM:SPD:719:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "BTRM:SPD:719:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "BTRM:SPD:719:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "BTRM:SPD:719:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "BTRM:SPD:719:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "BTRM:SPD:719:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "BTRM:SPD:719:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "BTRM:SPD:719:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "BTRM:SPD:719:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "BTRM:SPD:719:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BTRM:SPD:719:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BTRM:SPD:719:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BTRM:SPD:719:EDES.PROC PP")
    field(LNK2, "BTRM:SPD:719:EACT.PROC PP")
    field(LNK3, "BTRM:SPD:719:EERR.DISA PP")
    field(LNK4, "BTRM:SPD:719:ECON.PROC PP")
    field(LNK5, "BTRM:SPD:719:BMAGX.PROC PP")
    field(LNK6, "BTRM:SPD:719:BMAGY.PROC PP")
    field(LNK7, "BTRM:SPD:719:BLEM.PROC PP")
    field(LNK8, "BTRM:SPD:719:BMOD.PROC PP")
    field(LNK9, "BTRM:SPD:719:EDESSAVE.PROC PP")
    field(LNKA, "BTRM:SPD:719:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BTRM:SPD:719:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BTRM:SPD:719:BMAX")
  field(DOL2, "BTRM:SPD:719:BMAX")
  field(DOL3, "BTRM:SPD:719:BMAX")
  field(DOL4, "BTRM:SPD:719:BMIN")
  field(DOL5, "BTRM:SPD:719:BMIN")
  field(DOL6, "BTRM:SPD:719:BMIN")
  field(LNK1, "BTRM:SPD:719:BMAGX.HOPR")
  field(LNK2, "BTRM:SPD:719:BMAGY.HOPR")
  field(LNK3, "BTRM:SPD:719:BLEM.HOPR")
  field(LNK4, "BTRM:SPD:719:BMAGX.LOPR PP")
  field(LNK5, "BTRM:SPD:719:BMAGY.LOPR PP")
  field(LNK6, "BTRM:SPD:719:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BTRM:SPD:719:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BTRM:SPD:719:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BTRM:SPD:719:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BTRM:SPD:719:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "Amain")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BTRM:SPD:719:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPD:719:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPD:719:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPD:719:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BTRM:SPD:719:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BTRM:SPD:719:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BTRM:SPD:719:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BTRM:SPD:719:EDES NPP MS")
  field(INPB, "BTRM:SPD:719:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPD:330:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPD:330:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPD:330:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPD:330:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPD:330:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPD:330:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPD:330:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPD:330:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPD:330:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPD:330:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPD:330:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPD:330:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPD:330:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPD:330:EDES.PROC PP")
    field(LNK2, "QUAD:SPD:330:EACT.PROC PP")
    field(LNK3, "QUAD:SPD:330:EERR.DISA PP")
    field(LNK4, "QUAD:SPD:330:ECON.PROC PP")
    field(LNK5, "QUAD:SPD:330:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPD:330:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPD:330:BLEM.PROC PP")
    field(LNK8, "QUAD:SPD:330:BMOD.PROC PP")
    field(LNK9, "QUAD:SPD:330:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPD:330:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPD:330:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPD:330:BMAX")
  field(DOL2, "QUAD:SPD:330:BMAX")
  field(DOL3, "QUAD:SPD:330:BMAX")
  field(DOL4, "QUAD:SPD:330:BMIN")
  field(DOL5, "QUAD:SPD:330:BMIN")
  field(DOL6, "QUAD:SPD:330:BMIN")
  field(LNK1, "QUAD:SPD:330:BMAGX.HOPR")
  field(LNK2, "QUAD:SPD:330:BMAGY.HOPR")
  field(LNK3, "QUAD:SPD:330:BLEM.HOPR")
  field(LNK4, "QUAD:SPD:330:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPD:330:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPD:330:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:330:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:330:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPD:330:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPD:330:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPD:330:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:330:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:330:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:330:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:330:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:330:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPD:330:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPD:330:EDES NPP MS")
  field(INPB, "QUAD:SPD:330:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPD:340:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPD:340:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPD:340:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPD:340:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPD:340:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPD:340:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPD:340:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPD:340:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPD:340:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPD:340:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPD:340:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPD:340:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPD:340:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPD:340:EDES.PROC PP")
    field(LNK2, "QUAD:SPD:340:EACT.PROC PP")
    field(LNK3, "QUAD:SPD:340:EERR.DISA PP")
    field(LNK4, "QUAD:SPD:340:ECON.PROC PP")
    field(LNK5, "QUAD:SPD:340:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPD:340:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPD:340:BLEM.PROC PP")
    field(LNK8, "QUAD:SPD:340:BMOD.PROC PP")
    field(LNK9, "QUAD:SPD:340:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPD:340:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPD:340:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPD:340:BMAX")
  field(DOL2, "QUAD:SPD:340:BMAX")
  field(DOL3, "QUAD:SPD:340:BMAX")
  field(DOL4, "QUAD:SPD:340:BMIN")
  field(DOL5, "QUAD:SPD:340:BMIN")
  field(DOL6, "QUAD:SPD:340:BMIN")
  field(LNK1, "QUAD:SPD:340:BMAGX.HOPR")
  field(LNK2, "QUAD:SPD:340:BMAGY.HOPR")
  field(LNK3, "QUAD:SPD:340:BLEM.HOPR")
  field(LNK4, "QUAD:SPD:340:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPD:340:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPD:340:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:340:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:340:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPD:340:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPD:340:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPD:340:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:340:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:340:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:340:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:340:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:340:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPD:340:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPD:340:EDES NPP MS")
  field(INPB, "QUAD:SPD:340:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPD:690:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPD:690:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPD:690:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPD:690:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPD:690:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPD:690:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPD:690:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPD:690:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPD:690:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPD:690:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPD:690:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPD:690:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPD:690:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPD:690:EDES.PROC PP")
    field(LNK2, "QUAD:SPD:690:EACT.PROC PP")
    field(LNK3, "QUAD:SPD:690:EERR.DISA PP")
    field(LNK4, "QUAD:SPD:690:ECON.PROC PP")
    field(LNK5, "QUAD:SPD:690:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPD:690:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPD:690:BLEM.PROC PP")
    field(LNK8, "QUAD:SPD:690:BMOD.PROC PP")
    field(LNK9, "QUAD:SPD:690:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPD:690:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPD:690:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPD:690:BMAX")
  field(DOL2, "QUAD:SPD:690:BMAX")
  field(DOL3, "QUAD:SPD:690:BMAX")
  field(DOL4, "QUAD:SPD:690:BMIN")
  field(DOL5, "QUAD:SPD:690:BMIN")
  field(DOL6, "QUAD:SPD:690:BMIN")
  field(LNK1, "QUAD:SPD:690:BMAGX.HOPR")
  field(LNK2, "QUAD:SPD:690:BMAGY.HOPR")
  field(LNK3, "QUAD:SPD:690:BLEM.HOPR")
  field(LNK4, "QUAD:SPD:690:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPD:690:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPD:690:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:690:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:690:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPD:690:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPD:690:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPD:690:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:690:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:690:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:690:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:690:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:690:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPD:690:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPD:690:EDES NPP MS")
  field(INPB, "QUAD:SPD:690:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPD:700:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPD:700:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPD:700:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPD:700:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPD:700:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPD:700:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPD:700:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPD:700:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPD:700:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPD:700:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPD:700:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPD:700:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPD:700:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPD:700:EDES.PROC PP")
    field(LNK2, "QUAD:SPD:700:EACT.PROC PP")
    field(LNK3, "QUAD:SPD:700:EERR.DISA PP")
    field(LNK4, "QUAD:SPD:700:ECON.PROC PP")
    field(LNK5, "QUAD:SPD:700:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPD:700:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPD:700:BLEM.PROC PP")
    field(LNK8, "QUAD:SPD:700:BMOD.PROC PP")
    field(LNK9, "QUAD:SPD:700:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPD:700:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPD:700:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPD:700:BMAX")
  field(DOL2, "QUAD:SPD:700:BMAX")
  field(DOL3, "QUAD:SPD:700:BMAX")
  field(DOL4, "QUAD:SPD:700:BMIN")
  field(DOL5, "QUAD:SPD:700:BMIN")
  field(DOL6, "QUAD:SPD:700:BMIN")
  field(LNK1, "QUAD:SPD:700:BMAGX.HOPR")
  field(LNK2, "QUAD:SPD:700:BMAGY.HOPR")
  field(LNK3, "QUAD:SPD:700:BLEM.HOPR")
  field(LNK4, "QUAD:SPD:700:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPD:700:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPD:700:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:700:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPD:700:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPD:700:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPD:700:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPD:700:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:700:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:700:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:700:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPD:700:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:SPD:700:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPD:700:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPD:700:EDES NPP MS")
  field(INPB, "QUAD:SPD:700:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPD:334:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPD:334:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPD:334:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPD:334:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPD:334:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPD:334:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPD:334:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPD:334:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPD:334:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPD:334:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPD:334:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPD:334:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPD:334:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPD:334:EDES.PROC PP")
    field(LNK2, "XCOR:SPD:334:EACT.PROC PP")
    field(LNK3, "XCOR:SPD:334:EERR.DISA PP")
    field(LNK4, "XCOR:SPD:334:ECON.PROC PP")
    field(LNK5, "XCOR:SPD:334:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPD:334:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPD:334:BLEM.PROC PP")
    field(LNK8, "XCOR:SPD:334:BMOD.PROC PP")
    field(LNK9, "XCOR:SPD:334:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPD:334:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPD:334:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPD:334:BMAX")
  field(DOL2, "XCOR:SPD:334:BMAX")
  field(DOL3, "XCOR:SPD:334:BMAX")
  field(DOL4, "XCOR:SPD:334:BMIN")
  field(DOL5, "XCOR:SPD:334:BMIN")
  field(DOL6, "XCOR:SPD:334:BMIN")
  field(LNK1, "XCOR:SPD:334:BMAGX.HOPR")
  field(LNK2, "XCOR:SPD:334:BMAGY.HOPR")
  field(LNK3, "XCOR:SPD:334:BLEM.HOPR")
  field(LNK4, "XCOR:SPD:334:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPD:334:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPD:334:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPD:334:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPD:334:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPD:334:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPD:334:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPD:334:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:334:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:334:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPD:334:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:334:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPD:334:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPD:334:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPD:334:EDES NPP MS")
  field(INPB, "XCOR:SPD:334:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPD:688:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPD:688:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPD:688:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPD:688:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPD:688:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPD:688:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPD:688:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPD:688:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPD:688:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPD:688:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPD:688:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPD:688:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPD:688:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPD:688:EDES.PROC PP")
    field(LNK2, "XCOR:SPD:688:EACT.PROC PP")
    field(LNK3, "XCOR:SPD:688:EERR.DISA PP")
    field(LNK4, "XCOR:SPD:688:ECON.PROC PP")
    field(LNK5, "XCOR:SPD:688:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPD:688:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPD:688:BLEM.PROC PP")
    field(LNK8, "XCOR:SPD:688:BMOD.PROC PP")
    field(LNK9, "XCOR:SPD:688:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPD:688:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPD:688:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPD:688:BMAX")
  field(DOL2, "XCOR:SPD:688:BMAX")
  field(DOL3, "XCOR:SPD:688:BMAX")
  field(DOL4, "XCOR:SPD:688:BMIN")
  field(DOL5, "XCOR:SPD:688:BMIN")
  field(DOL6, "XCOR:SPD:688:BMIN")
  field(LNK1, "XCOR:SPD:688:BMAGX.HOPR")
  field(LNK2, "XCOR:SPD:688:BMAGY.HOPR")
  field(LNK3, "XCOR:SPD:688:BLEM.HOPR")
  field(LNK4, "XCOR:SPD:688:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPD:688:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPD:688:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPD:688:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPD:688:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPD:688:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPD:688:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPD:688:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:688:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:688:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPD:688:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:688:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPD:688:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPD:688:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPD:688:EDES NPP MS")
  field(INPB, "XCOR:SPD:688:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:SPD:964:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "XCOR:SPD:964:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:SPD:964:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:SPD:964:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:SPD:964:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:SPD:964:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:SPD:964:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:SPD:964:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:SPD:964:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:SPD:964:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:SPD:964:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:SPD:964:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:SPD:964:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:SPD:964:EDES.PROC PP")
    field(LNK2, "XCOR:SPD:964:EACT.PROC PP")
    field(LNK3, "XCOR:SPD:964:EERR.DISA PP")
    field(LNK4, "XCOR:SPD:964:ECON.PROC PP")
    field(LNK5, "XCOR:SPD:964:BMAGX.PROC PP")
    field(LNK6, "XCOR:SPD:964:BMAGY.PROC PP")
    field(LNK7, "XCOR:SPD:964:BLEM.PROC PP")
    field(LNK8, "XCOR:SPD:964:BMOD.PROC PP")
    field(LNK9, "XCOR:SPD:964:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:SPD:964:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:SPD:964:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:SPD:964:BMAX")
  field(DOL2, "XCOR:SPD:964:BMAX")
  field(DOL3, "XCOR:SPD:964:BMAX")
  field(DOL4, "XCOR:SPD:964:BMIN")
  field(DOL5, "XCOR:SPD:964:BMIN")
  field(DOL6, "XCOR:SPD:964:BMIN")
  field(LNK1, "XCOR:SPD:964:BMAGX.HOPR")
  field(LNK2, "XCOR:SPD:964:BMAGY.HOPR")
  field(LNK3, "XCOR:SPD:964:BLEM.HOPR")
  field(LNK4, "XCOR:SPD:964:BMAGX.LOPR PP")
  field(LNK5, "XCOR:SPD:964:BMAGY.LOPR PP")
  field(LNK6, "XCOR:SPD:964:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:SPD:964:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:SPD:964:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:SPD:964:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:SPD:964:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:SPD:964:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:964:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:964:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPD:964:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:SPD:964:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:SPD:964:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:SPD:964:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:SPD:964:EDES NPP MS")
  field(INPB, "XCOR:SPD:964:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPD:343:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPD:343:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPD:343:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPD:343:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPD:343:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPD:343:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPD:343:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPD:343:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPD:343:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPD:343:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPD:343:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPD:343:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPD:343:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPD:343:EDES.PROC PP")
    field(LNK2, "YCOR:SPD:343:EACT.PROC PP")
    field(LNK3, "YCOR:SPD:343:EERR.DISA PP")
    field(LNK4, "YCOR:SPD:343:ECON.PROC PP")
    field(LNK5, "YCOR:SPD:343:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPD:343:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPD:343:BLEM.PROC PP")
    field(LNK8, "YCOR:SPD:343:BMOD.PROC PP")
    field(LNK9, "YCOR:SPD:343:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPD:343:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPD:343:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPD:343:BMAX")
  field(DOL2, "YCOR:SPD:343:BMAX")
  field(DOL3, "YCOR:SPD:343:BMAX")
  field(DOL4, "YCOR:SPD:343:BMIN")
  field(DOL5, "YCOR:SPD:343:BMIN")
  field(DOL6, "YCOR:SPD:343:BMIN")
  field(LNK1, "YCOR:SPD:343:BMAGX.HOPR")
  field(LNK2, "YCOR:SPD:343:BMAGY.HOPR")
  field(LNK3, "YCOR:SPD:343:BLEM.HOPR")
  field(LNK4, "YCOR:SPD:343:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPD:343:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPD:343:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPD:343:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPD:343:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPD:343:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPD:343:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPD:343:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:343:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:343:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPD:343:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:343:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPD:343:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPD:343:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPD:343:EDES NPP MS")
  field(INPB, "YCOR:SPD:343:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPD:703:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPD:703:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPD:703:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPD:703:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPD:703:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPD:703:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPD:703:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPD:703:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPD:703:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPD:703:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPD:703:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPD:703:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPD:703:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPD:703:EDES.PROC PP")
    field(LNK2, "YCOR:SPD:703:EACT.PROC PP")
    field(LNK3, "YCOR:SPD:703:EERR.DISA PP")
    field(LNK4, "YCOR:SPD:703:ECON.PROC PP")
    field(LNK5, "YCOR:SPD:703:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPD:703:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPD:703:BLEM.PROC PP")
    field(LNK8, "YCOR:SPD:703:BMOD.PROC PP")
    field(LNK9, "YCOR:SPD:703:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPD:703:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPD:703:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPD:703:BMAX")
  field(DOL2, "YCOR:SPD:703:BMAX")
  field(DOL3, "YCOR:SPD:703:BMAX")
  field(DOL4, "YCOR:SPD:703:BMIN")
  field(DOL5, "YCOR:SPD:703:BMIN")
  field(DOL6, "YCOR:SPD:703:BMIN")
  field(LNK1, "YCOR:SPD:703:BMAGX.HOPR")
  field(LNK2, "YCOR:SPD:703:BMAGY.HOPR")
  field(LNK3, "YCOR:SPD:703:BLEM.HOPR")
  field(LNK4, "YCOR:SPD:703:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPD:703:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPD:703:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPD:703:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPD:703:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPD:703:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPD:703:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPD:703:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:703:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:703:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPD:703:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:703:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPD:703:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPD:703:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPD:703:EDES NPP MS")
  field(INPB, "YCOR:SPD:703:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:SPD:965:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "YCOR:SPD:965:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:SPD:965:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:SPD:965:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:SPD:965:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:SPD:965:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:SPD:965:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:SPD:965:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:SPD:965:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:SPD:965:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:SPD:965:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:SPD:965:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:SPD:965:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:SPD:965:EDES.PROC PP")
    field(LNK2, "YCOR:SPD:965:EACT.PROC PP")
    field(LNK3, "YCOR:SPD:965:EERR.DISA PP")
    field(LNK4, "YCOR:SPD:965:ECON.PROC PP")
    field(LNK5, "YCOR:SPD:965:BMAGX.PROC PP")
    field(LNK6, "YCOR:SPD:965:BMAGY.PROC PP")
    field(LNK7, "YCOR:SPD:965:BLEM.PROC PP")
    field(LNK8, "YCOR:SPD:965:BMOD.PROC PP")
    field(LNK9, "YCOR:SPD:965:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:SPD:965:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:SPD:965:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:SPD:965:BMAX")
  field(DOL2, "YCOR:SPD:965:BMAX")
  field(DOL3, "YCOR:SPD:965:BMAX")
  field(DOL4, "YCOR:SPD:965:BMIN")
  field(DOL5, "YCOR:SPD:965:BMIN")
  field(DOL6, "YCOR:SPD:965:BMIN")
  field(LNK1, "YCOR:SPD:965:BMAGX.HOPR")
  field(LNK2, "YCOR:SPD:965:BMAGY.HOPR")
  field(LNK3, "YCOR:SPD:965:BLEM.HOPR")
  field(LNK4, "YCOR:SPD:965:BMAGX.LOPR PP")
  field(LNK5, "YCOR:SPD:965:BMAGY.LOPR PP")
  field(LNK6, "YCOR:SPD:965:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:SPD:965:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:SPD:965:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:SPD:965:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:SPD:965:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:SPD:965:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:965:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:965:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPD:965:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:SPD:965:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:SPD:965:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:SPD:965:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:SPD:965:EDES NPP MS")
  field(INPB, "YCOR:SPD:965:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SLTH:220:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SLTH:220:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SLTH:220:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SLTH:220:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SLTH:220:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SLTH:220:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SLTH:220:EDES.PROC PP")
    field(LNK2, "QUAD:SLTH:220:EACT.PROC PP")
    field(LNK3, "QUAD:SLTH:220:EERR.DISA PP")
    field(LNK4, "QUAD:SLTH:220:ECON.PROC PP")
    field(LNK5, "QUAD:SLTH:220:BMAGX.PROC PP")
    field(LNK6, "QUAD:SLTH:220:BMAGY.PROC PP")
    field(LNK7, "QUAD:SLTH:220:BLEM.PROC PP")
    field(LNK8, "QUAD:SLTH:220:BMOD.PROC PP")
    field(LNK9, "QUAD:SLTH:220:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SLTH:220:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SLTH:220:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SLTH:220:BMAX")
  field(DOL2, "QUAD:SLTH:220:BMAX")
  field(DOL3, "QUAD:SLTH:220:BMAX")
  field(DOL4, "QUAD:SLTH:220:BMIN")
  field(DOL5, "QUAD:SLTH:220:BMIN")
  field(DOL6, "QUAD:SLTH:220:BMIN")
  field(LNK1, "QUAD:SLTH:220:BMAGX.HOPR")
  field(LNK2, "QUAD:SLTH:220:BMAGY.HOPR")
  field(LNK3, "QUAD:SLTH:220:BLEM.HOPR")
  field(LNK4, "QUAD:SLTH:220:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SLTH:220:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SLTH:220:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTH:220:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SLTH:220:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SLTH:220:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SLTH:220:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SLTH:220:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTH:220:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPH:320:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTH:220:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:320:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SLTH:220:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SLTH:220:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:320:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SLTH:220:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SLTH:220:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SLTH:220:EDES NPP MS")
  field(INPB, "QUAD:SLTH:220:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:SPH:115:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "KICK:SPH:115:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:SPH:115:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:SPH:115:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:SPH:115:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:SPH:115:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:SPH:115:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:SPH:115:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:SPH:115:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:SPH:115:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:SPH:115:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:SPH:115:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:SPH:115:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:SPH:115:EDES.PROC PP")
    field(LNK2, "KICK:SPH:115:EACT.PROC PP")
    field(LNK3, "KICK:SPH:115:EERR.DISA PP")
    field(LNK4, "KICK:SPH:115:ECON.PROC PP")
    field(LNK5, "KICK:SPH:115:BMAGX.PROC PP")
    field(LNK6, "KICK:SPH:115:BMAGY.PROC PP")
    field(LNK7, "KICK:SPH:115:BLEM.PROC PP")
    field(LNK8, "KICK:SPH:115:BMOD.PROC PP")
    field(LNK9, "KICK:SPH:115:EDESSAVE.PROC PP")
    field(LNKA, "KICK:SPH:115:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:SPH:115:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:SPH:115:BMAX")
  field(DOL2, "KICK:SPH:115:BMAX")
  field(DOL3, "KICK:SPH:115:BMAX")
  field(DOL4, "KICK:SPH:115:BMIN")
  field(DOL5, "KICK:SPH:115:BMIN")
  field(DOL6, "KICK:SPH:115:BMIN")
  field(LNK1, "KICK:SPH:115:BMAGX.HOPR")
  field(LNK2, "KICK:SPH:115:BMAGY.HOPR")
  field(LNK3, "KICK:SPH:115:BLEM.HOPR")
  field(LNK4, "KICK:SPH:115:BMAGX.LOPR PP")
  field(LNK5, "KICK:SPH:115:BMAGY.LOPR PP")
  field(LNK6, "KICK:SPH:115:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:SPH:115:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:SPH:115:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:SPH:115:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:SPH:115:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:SPH:115:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:115:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:SPH:110:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:115:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:SPH:110:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPH:115:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:115:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:SPH:110:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPH:115:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:SPH:115:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:SPH:115:EDES NPP MS")
  field(INPB, "KICK:SPH:115:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:SPH:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "KICK:SPH:120:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:SPH:120:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:SPH:120:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:SPH:120:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:SPH:120:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:SPH:120:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:SPH:120:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:SPH:120:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:SPH:120:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:SPH:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:SPH:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:SPH:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:SPH:120:EDES.PROC PP")
    field(LNK2, "KICK:SPH:120:EACT.PROC PP")
    field(LNK3, "KICK:SPH:120:EERR.DISA PP")
    field(LNK4, "KICK:SPH:120:ECON.PROC PP")
    field(LNK5, "KICK:SPH:120:BMAGX.PROC PP")
    field(LNK6, "KICK:SPH:120:BMAGY.PROC PP")
    field(LNK7, "KICK:SPH:120:BLEM.PROC PP")
    field(LNK8, "KICK:SPH:120:BMOD.PROC PP")
    field(LNK9, "KICK:SPH:120:EDESSAVE.PROC PP")
    field(LNKA, "KICK:SPH:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:SPH:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:SPH:120:BMAX")
  field(DOL2, "KICK:SPH:120:BMAX")
  field(DOL3, "KICK:SPH:120:BMAX")
  field(DOL4, "KICK:SPH:120:BMIN")
  field(DOL5, "KICK:SPH:120:BMIN")
  field(DOL6, "KICK:SPH:120:BMIN")
  field(LNK1, "KICK:SPH:120:BMAGX.HOPR")
  field(LNK2, "KICK:SPH:120:BMAGY.HOPR")
  field(LNK3, "KICK:SPH:120:BLEM.HOPR")
  field(LNK4, "KICK:SPH:120:BMAGX.LOPR PP")
  field(LNK5, "KICK:SPH:120:BMAGY.LOPR PP")
  field(LNK6, "KICK:SPH:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:SPH:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:SPH:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:SPH:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:SPH:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:SPH:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:SPH:110:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:SPH:110:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPH:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPH:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:SPH:110:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPH:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:SPH:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:SPH:120:EDES NPP MS")
  field(INPB, "KICK:SPH:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:760:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:760:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:760:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:760:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:760:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:760:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:760:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:760:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:760:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:760:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:760:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:760:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:760:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:760:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:760:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:760:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:760:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:760:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:760:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:760:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:760:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:760:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:760:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:760:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:760:BMAX")
  field(DOL2, "QUAD:SPH:760:BMAX")
  field(DOL3, "QUAD:SPH:760:BMAX")
  field(DOL4, "QUAD:SPH:760:BMIN")
  field(DOL5, "QUAD:SPH:760:BMIN")
  field(DOL6, "QUAD:SPH:760:BMIN")
  field(LNK1, "QUAD:SPH:760:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:760:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:760:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:760:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:760:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:760:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:760:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:760:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:760:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:760:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:760:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:760:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPH:600:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:760:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:600:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:760:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:760:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:600:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:760:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:760:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:760:EDES NPP MS")
  field(INPB, "QUAD:SPH:760:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:840:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:840:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:840:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:840:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:840:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:840:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:840:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:840:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:840:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:840:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:840:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:840:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:840:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:840:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:840:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:840:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:840:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:840:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:840:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:840:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:840:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:840:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:840:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:840:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:840:BMAX")
  field(DOL2, "QUAD:SPH:840:BMAX")
  field(DOL3, "QUAD:SPH:840:BMAX")
  field(DOL4, "QUAD:SPH:840:BMIN")
  field(DOL5, "QUAD:SPH:840:BMIN")
  field(DOL6, "QUAD:SPH:840:BMIN")
  field(LNK1, "QUAD:SPH:840:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:840:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:840:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:840:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:840:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:840:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:840:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:840:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:840:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:840:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:840:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:840:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPH:520:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:840:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:520:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:840:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:840:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:520:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:840:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:840:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:840:EDES NPP MS")
  field(INPB, "QUAD:SPH:840:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:920:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:920:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:920:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:920:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:920:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:920:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:920:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:920:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:920:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:920:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:920:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:920:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:920:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:920:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:920:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:920:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:920:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:920:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:920:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:920:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:920:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:920:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:920:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:920:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:920:BMAX")
  field(DOL2, "QUAD:SPH:920:BMAX")
  field(DOL3, "QUAD:SPH:920:BMAX")
  field(DOL4, "QUAD:SPH:920:BMIN")
  field(DOL5, "QUAD:SPH:920:BMIN")
  field(DOL6, "QUAD:SPH:920:BMIN")
  field(LNK1, "QUAD:SPH:920:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:920:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:920:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:920:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:920:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:920:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:920:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:920:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:920:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:920:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:920:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:920:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPH:450:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:920:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:450:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:920:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:920:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:450:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:920:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:920:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:920:EDES NPP MS")
  field(INPB, "QUAD:SPH:920:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPH:940:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPH:940:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPH:940:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPH:940:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPH:940:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPH:940:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPH:940:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPH:940:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPH:940:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPH:940:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPH:940:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPH:940:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPH:940:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPH:940:EDES.PROC PP")
    field(LNK2, "QUAD:SPH:940:EACT.PROC PP")
    field(LNK3, "QUAD:SPH:940:EERR.DISA PP")
    field(LNK4, "QUAD:SPH:940:ECON.PROC PP")
    field(LNK5, "QUAD:SPH:940:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPH:940:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPH:940:BLEM.PROC PP")
    field(LNK8, "QUAD:SPH:940:BMOD.PROC PP")
    field(LNK9, "QUAD:SPH:940:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPH:940:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPH:940:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPH:940:BMAX")
  field(DOL2, "QUAD:SPH:940:BMAX")
  field(DOL3, "QUAD:SPH:940:BMAX")
  field(DOL4, "QUAD:SPH:940:BMIN")
  field(DOL5, "QUAD:SPH:940:BMIN")
  field(DOL6, "QUAD:SPH:940:BMIN")
  field(LNK1, "QUAD:SPH:940:BMAGX.HOPR")
  field(LNK2, "QUAD:SPH:940:BMAGY.HOPR")
  field(LNK3, "QUAD:SPH:940:BLEM.HOPR")
  field(LNK4, "QUAD:SPH:940:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPH:940:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPH:940:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:940:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPH:940:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPH:940:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPH:940:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPH:940:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:940:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPH:420:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:940:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:420:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:940:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPH:940:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPH:420:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPH:940:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPH:940:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPH:940:EDES NPP MS")
  field(INPB, "QUAD:SPH:940:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:SPS:390:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "KICK:SPS:390:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:SPS:390:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:SPS:390:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:SPS:390:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:SPS:390:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:SPS:390:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:SPS:390:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:SPS:390:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:SPS:390:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:SPS:390:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:SPS:390:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:SPS:390:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:SPS:390:EDES.PROC PP")
    field(LNK2, "KICK:SPS:390:EACT.PROC PP")
    field(LNK3, "KICK:SPS:390:EERR.DISA PP")
    field(LNK4, "KICK:SPS:390:ECON.PROC PP")
    field(LNK5, "KICK:SPS:390:BMAGX.PROC PP")
    field(LNK6, "KICK:SPS:390:BMAGY.PROC PP")
    field(LNK7, "KICK:SPS:390:BLEM.PROC PP")
    field(LNK8, "KICK:SPS:390:BMOD.PROC PP")
    field(LNK9, "KICK:SPS:390:EDESSAVE.PROC PP")
    field(LNKA, "KICK:SPS:390:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:SPS:390:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:SPS:390:BMAX")
  field(DOL2, "KICK:SPS:390:BMAX")
  field(DOL3, "KICK:SPS:390:BMAX")
  field(DOL4, "KICK:SPS:390:BMIN")
  field(DOL5, "KICK:SPS:390:BMIN")
  field(DOL6, "KICK:SPS:390:BMIN")
  field(LNK1, "KICK:SPS:390:BMAGX.HOPR")
  field(LNK2, "KICK:SPS:390:BMAGY.HOPR")
  field(LNK3, "KICK:SPS:390:BLEM.HOPR")
  field(LNK4, "KICK:SPS:390:BMAGX.LOPR PP")
  field(LNK5, "KICK:SPS:390:BMAGY.LOPR PP")
  field(LNK6, "KICK:SPS:390:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:SPS:390:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:SPS:390:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:SPS:390:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:SPS:390:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:SPS:390:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:390:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:SPS:385:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:390:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:SPS:385:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPS:390:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:390:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:SPS:385:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPS:390:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:SPS:390:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:SPS:390:EDES NPP MS")
  field(INPB, "KICK:SPS:390:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:SPS:395:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPH:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPH:1:CTRL.RVAL")
  field(LNK1, "KICK:SPS:395:FUNC CA PP")
  field(DOL2, "MGNT:SPH:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:SPS:395:FUNC CA PP")
  field(DOL3, "MGNT:SPH:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:SPS:395:FUNC CA PP")
  field(DOL4, "MGNT:SPH:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:SPS:395:FUNC CA PP")
  field(DOL5, "MGNT:SPH:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:SPS:395:FUNC CA PP")
  field(DOL6, "MGNT:SPH:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:SPS:395:FUNC CA PP")
  field(DOL7, "MGNT:SPH:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:SPS:395:FUNC CA PP")
  field(DOL8, "MGNT:SPH:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:SPS:395:FUNC CA PP")
  field(DOL9, "MGNT:SPH:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:SPS:395:FUNC CA PP")
  field(DOLA, "MGNT:SPH:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:SPS:395:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:SPS:395:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:SPS:395:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:SPS:395:EDES.PROC PP")
    field(LNK2, "KICK:SPS:395:EACT.PROC PP")
    field(LNK3, "KICK:SPS:395:EERR.DISA PP")
    field(LNK4, "KICK:SPS:395:ECON.PROC PP")
    field(LNK5, "KICK:SPS:395:BMAGX.PROC PP")
    field(LNK6, "KICK:SPS:395:BMAGY.PROC PP")
    field(LNK7, "KICK:SPS:395:BLEM.PROC PP")
    field(LNK8, "KICK:SPS:395:BMOD.PROC PP")
    field(LNK9, "KICK:SPS:395:EDESSAVE.PROC PP")
    field(LNKA, "KICK:SPS:395:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:SPS:395:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:SPS:395:BMAX")
  field(DOL2, "KICK:SPS:395:BMAX")
  field(DOL3, "KICK:SPS:395:BMAX")
  field(DOL4, "KICK:SPS:395:BMIN")
  field(DOL5, "KICK:SPS:395:BMIN")
  field(DOL6, "KICK:SPS:395:BMIN")
  field(LNK1, "KICK:SPS:395:BMAGX.HOPR")
  field(LNK2, "KICK:SPS:395:BMAGY.HOPR")
  field(LNK3, "KICK:SPS:395:BLEM.HOPR")
  field(LNK4, "KICK:SPS:395:BMAGX.LOPR PP")
  field(LNK5, "KICK:SPS:395:BMAGY.LOPR PP")
  field(LNK6, "KICK:SPS:395:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:SPS:395:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:SPS:395:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:SPS:395:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:SPS:395:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:SPS:395:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:395:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:SPS:385:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:395:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:SPS:385:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPS:395:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:SPS:395:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:SPS:385:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:SPS:395:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:SPS:395:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:SPS:395:EDES NPP MS")
  field(INPB, "KICK:SPS:395:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPS:470:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BEND:SPS:470:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPS:470:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPS:470:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPS:470:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPS:470:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPS:470:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPS:470:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPS:470:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPS:470:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPS:470:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPS:470:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPS:470:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPS:470:EDES.PROC PP")
    field(LNK2, "BEND:SPS:470:EACT.PROC PP")
    field(LNK3, "BEND:SPS:470:EERR.DISA PP")
    field(LNK4, "BEND:SPS:470:ECON.PROC PP")
    field(LNK5, "BEND:SPS:470:BMAGX.PROC PP")
    field(LNK6, "BEND:SPS:470:BMAGY.PROC PP")
    field(LNK7, "BEND:SPS:470:BLEM.PROC PP")
    field(LNK8, "BEND:SPS:470:BMOD.PROC PP")
    field(LNK9, "BEND:SPS:470:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPS:470:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPS:470:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPS:470:BMAX")
  field(DOL2, "BEND:SPS:470:BMAX")
  field(DOL3, "BEND:SPS:470:BMAX")
  field(DOL4, "BEND:SPS:470:BMIN")
  field(DOL5, "BEND:SPS:470:BMIN")
  field(DOL6, "BEND:SPS:470:BMIN")
  field(LNK1, "BEND:SPS:470:BMAGX.HOPR")
  field(LNK2, "BEND:SPS:470:BMAGY.HOPR")
  field(LNK3, "BEND:SPS:470:BLEM.HOPR")
  field(LNK4, "BEND:SPS:470:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPS:470:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPS:470:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:470:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:470:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPS:470:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPS:470:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPS:470:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:470:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:SPS:800:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:470:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:SPS:800:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPS:470:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:470:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:SPS:800:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPS:470:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPS:470:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPS:470:EDES NPP MS")
  field(INPB, "BEND:SPS:470:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPS:610:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BEND:SPS:610:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPS:610:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPS:610:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPS:610:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPS:610:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPS:610:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPS:610:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPS:610:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPS:610:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPS:610:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPS:610:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPS:610:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPS:610:EDES.PROC PP")
    field(LNK2, "BEND:SPS:610:EACT.PROC PP")
    field(LNK3, "BEND:SPS:610:EERR.DISA PP")
    field(LNK4, "BEND:SPS:610:ECON.PROC PP")
    field(LNK5, "BEND:SPS:610:BMAGX.PROC PP")
    field(LNK6, "BEND:SPS:610:BMAGY.PROC PP")
    field(LNK7, "BEND:SPS:610:BLEM.PROC PP")
    field(LNK8, "BEND:SPS:610:BMOD.PROC PP")
    field(LNK9, "BEND:SPS:610:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPS:610:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPS:610:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPS:610:BMAX")
  field(DOL2, "BEND:SPS:610:BMAX")
  field(DOL3, "BEND:SPS:610:BMAX")
  field(DOL4, "BEND:SPS:610:BMIN")
  field(DOL5, "BEND:SPS:610:BMIN")
  field(DOL6, "BEND:SPS:610:BMIN")
  field(LNK1, "BEND:SPS:610:BMAGX.HOPR")
  field(LNK2, "BEND:SPS:610:BMAGY.HOPR")
  field(LNK3, "BEND:SPS:610:BLEM.HOPR")
  field(LNK4, "BEND:SPS:610:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPS:610:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPS:610:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:610:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:610:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPS:610:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPS:610:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPS:610:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:610:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:SPS:800:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:610:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:SPS:800:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPS:610:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:610:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:SPS:800:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPS:610:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPS:610:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPS:610:EDES NPP MS")
  field(INPB, "BEND:SPS:610:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPS:950:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "BEND:SPS:950:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPS:950:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPS:950:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPS:950:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPS:950:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPS:950:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPS:950:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPS:950:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPS:950:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPS:950:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPS:950:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPS:950:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPS:950:EDES.PROC PP")
    field(LNK2, "BEND:SPS:950:EACT.PROC PP")
    field(LNK3, "BEND:SPS:950:EERR.DISA PP")
    field(LNK4, "BEND:SPS:950:ECON.PROC PP")
    field(LNK5, "BEND:SPS:950:BMAGX.PROC PP")
    field(LNK6, "BEND:SPS:950:BMAGY.PROC PP")
    field(LNK7, "BEND:SPS:950:BLEM.PROC PP")
    field(LNK8, "BEND:SPS:950:BMOD.PROC PP")
    field(LNK9, "BEND:SPS:950:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPS:950:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPS:950:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPS:950:BMAX")
  field(DOL2, "BEND:SPS:950:BMAX")
  field(DOL3, "BEND:SPS:950:BMAX")
  field(DOL4, "BEND:SPS:950:BMIN")
  field(DOL5, "BEND:SPS:950:BMIN")
  field(DOL6, "BEND:SPS:950:BMIN")
  field(LNK1, "BEND:SPS:950:BMAGX.HOPR")
  field(LNK2, "BEND:SPS:950:BMAGY.HOPR")
  field(LNK3, "BEND:SPS:950:BLEM.HOPR")
  field(LNK4, "BEND:SPS:950:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPS:950:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPS:950:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:950:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPS:950:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPS:950:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPS:950:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPS:950:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:950:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:SPS:800:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:950:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:SPS:800:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPS:950:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPS:950:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:SPS:800:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPS:950:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPS:950:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPS:950:EDES NPP MS")
  field(INPB, "BEND:SPS:950:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:770:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:770:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:770:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:770:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:770:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:770:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:770:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:770:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:770:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:770:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:770:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:770:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:770:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:770:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:770:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:770:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:770:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:770:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:770:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:770:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:770:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:770:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:770:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:770:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:770:BMAX")
  field(DOL2, "QUAD:SPS:770:BMAX")
  field(DOL3, "QUAD:SPS:770:BMAX")
  field(DOL4, "QUAD:SPS:770:BMIN")
  field(DOL5, "QUAD:SPS:770:BMIN")
  field(DOL6, "QUAD:SPS:770:BMIN")
  field(LNK1, "QUAD:SPS:770:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:770:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:770:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:770:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:770:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:770:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:770:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:770:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:770:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:770:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:770:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:770:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPS:650:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:770:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:650:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:770:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:770:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:650:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:770:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:770:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:770:EDES NPP MS")
  field(INPB, "QUAD:SPS:770:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:780:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:780:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:780:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:780:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:780:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:780:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:780:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:780:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:780:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:780:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:780:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:780:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:780:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:780:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:780:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:780:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:780:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:780:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:780:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:780:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:780:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:780:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:780:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:780:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:780:BMAX")
  field(DOL2, "QUAD:SPS:780:BMAX")
  field(DOL3, "QUAD:SPS:780:BMAX")
  field(DOL4, "QUAD:SPS:780:BMIN")
  field(DOL5, "QUAD:SPS:780:BMIN")
  field(DOL6, "QUAD:SPS:780:BMIN")
  field(LNK1, "QUAD:SPS:780:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:780:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:780:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:780:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:780:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:780:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:780:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:780:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:780:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:780:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:780:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:780:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPS:640:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:780:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:640:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:780:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:780:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:640:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:780:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:780:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:780:EDES NPP MS")
  field(INPB, "QUAD:SPS:780:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:830:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:830:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:830:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:830:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:830:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:830:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:830:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:830:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:830:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:830:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:830:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:830:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:830:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:830:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:830:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:830:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:830:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:830:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:830:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:830:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:830:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:830:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:830:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:830:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:830:BMAX")
  field(DOL2, "QUAD:SPS:830:BMAX")
  field(DOL3, "QUAD:SPS:830:BMAX")
  field(DOL4, "QUAD:SPS:830:BMIN")
  field(DOL5, "QUAD:SPS:830:BMIN")
  field(DOL6, "QUAD:SPS:830:BMIN")
  field(LNK1, "QUAD:SPS:830:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:830:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:830:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:830:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:830:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:830:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:830:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:830:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:830:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:830:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:830:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:830:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPS:580:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:830:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:580:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:830:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:830:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:580:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:830:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:830:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:830:EDES NPP MS")
  field(INPB, "QUAD:SPS:830:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:SPS:840:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPS:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPS:1:CTRL.RVAL")
  field(LNK1, "QUAD:SPS:840:FUNC CA PP")
  field(DOL2, "MGNT:SPS:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:SPS:840:FUNC CA PP")
  field(DOL3, "MGNT:SPS:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:SPS:840:FUNC CA PP")
  field(DOL4, "MGNT:SPS:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:SPS:840:FUNC CA PP")
  field(DOL5, "MGNT:SPS:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:SPS:840:FUNC CA PP")
  field(DOL6, "MGNT:SPS:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:SPS:840:FUNC CA PP")
  field(DOL7, "MGNT:SPS:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:SPS:840:FUNC CA PP")
  field(DOL8, "MGNT:SPS:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:SPS:840:FUNC CA PP")
  field(DOL9, "MGNT:SPS:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:SPS:840:FUNC CA PP")
  field(DOLA, "MGNT:SPS:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:SPS:840:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:SPS:840:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:SPS:840:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:SPS:840:EDES.PROC PP")
    field(LNK2, "QUAD:SPS:840:EACT.PROC PP")
    field(LNK3, "QUAD:SPS:840:EERR.DISA PP")
    field(LNK4, "QUAD:SPS:840:ECON.PROC PP")
    field(LNK5, "QUAD:SPS:840:BMAGX.PROC PP")
    field(LNK6, "QUAD:SPS:840:BMAGY.PROC PP")
    field(LNK7, "QUAD:SPS:840:BLEM.PROC PP")
    field(LNK8, "QUAD:SPS:840:BMOD.PROC PP")
    field(LNK9, "QUAD:SPS:840:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:SPS:840:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:SPS:840:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:SPS:840:BMAX")
  field(DOL2, "QUAD:SPS:840:BMAX")
  field(DOL3, "QUAD:SPS:840:BMAX")
  field(DOL4, "QUAD:SPS:840:BMIN")
  field(DOL5, "QUAD:SPS:840:BMIN")
  field(DOL6, "QUAD:SPS:840:BMIN")
  field(LNK1, "QUAD:SPS:840:BMAGX.HOPR")
  field(LNK2, "QUAD:SPS:840:BMAGY.HOPR")
  field(LNK3, "QUAD:SPS:840:BLEM.HOPR")
  field(LNK4, "QUAD:SPS:840:BMAGX.LOPR PP")
  field(LNK5, "QUAD:SPS:840:BMAGY.LOPR PP")
  field(LNK6, "QUAD:SPS:840:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:840:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:SPS:840:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:SPS:840:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:SPS:840:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:SPS:840:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:840:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:SPS:570:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:840:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:570:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:840:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:SPS:840:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:SPS:570:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:SPS:840:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:SPS:840:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:SPS:840:EDES NPP MS")
  field(INPB, "QUAD:SPS:840:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:SPD:719:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:SPD:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:SPD:1:CTRL.RVAL")
  field(LNK1, "BEND:SPD:719:FUNC CA PP")
  field(DOL2, "MGNT:SPD:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:SPD:719:FUNC CA PP")
  field(DOL3, "MGNT:SPD:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:SPD:719:FUNC CA PP")
  field(DOL4, "MGNT:SPD:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:SPD:719:FUNC CA PP")
  field(DOL5, "MGNT:SPD:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:SPD:719:FUNC CA PP")
  field(DOL6, "MGNT:SPD:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:SPD:719:FUNC CA PP")
  field(DOL7, "MGNT:SPD:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:SPD:719:FUNC CA PP")
  field(DOL8, "MGNT:SPD:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:SPD:719:FUNC CA PP")
  field(DOL9, "MGNT:SPD:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:SPD:719:FUNC CA PP")
  field(DOLA, "MGNT:SPD:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:SPD:719:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:SPD:719:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:SPD:719:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:SPD:719:EDES.PROC PP")
    field(LNK2, "BEND:SPD:719:EACT.PROC PP")
    field(LNK3, "BEND:SPD:719:EERR.DISA PP")
    field(LNK4, "BEND:SPD:719:ECON.PROC PP")
    field(LNK5, "BEND:SPD:719:BMAGX.PROC PP")
    field(LNK6, "BEND:SPD:719:BMAGY.PROC PP")
    field(LNK7, "BEND:SPD:719:BLEM.PROC PP")
    field(LNK8, "BEND:SPD:719:BMOD.PROC PP")
    field(LNK9, "BEND:SPD:719:EDESSAVE.PROC PP")
    field(LNKA, "BEND:SPD:719:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:SPD:719:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:SPD:719:BMAX")
  field(DOL2, "BEND:SPD:719:BMAX")
  field(DOL3, "BEND:SPD:719:BMAX")
  field(DOL4, "BEND:SPD:719:BMIN")
  field(DOL5, "BEND:SPD:719:BMIN")
  field(DOL6, "BEND:SPD:719:BMIN")
  field(LNK1, "BEND:SPD:719:BMAGX.HOPR")
  field(LNK2, "BEND:SPD:719:BMAGY.HOPR")
  field(LNK3, "BEND:SPD:719:BLEM.HOPR")
  field(LNK4, "BEND:SPD:719:BMAGX.LOPR PP")
  field(LNK5, "BEND:SPD:719:BMAGY.LOPR PP")
  field(LNK6, "BEND:SPD:719:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:SPD:719:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:SPD:719:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:SPD:719:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:SPD:719:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:SPD:719:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPD:719:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "BEND:SPD:960:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPD:719:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "BEND:SPD:960:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPD:719:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:SPD:719:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "BEND:SPD:960:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "BEND:SPD:719:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:SPD:719:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:SPD:719:EDES NPP MS")
  field(INPB, "BEND:SPD:719:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND


record(longout, "MGNT:DASEL:1:CTRLSWITCH") {
}

# The LNK# (1-8) MUST corresponsds to the magent
# type definition found in the file mgntCtrl.h.
# For example, MGNT_TYPE_BEND is defined as 2 and is LNK2 below.
# If the LNK order is changes you will need to make the
# corresponding change the pv <device>:<type>CTRL which is
# found in the files mgnt_ctrl_allstar.substitutions
# The field FFVL value in MGNT:<LOCA>:1: CTRLCLEAR MUST be set
# to the value for MGNT_TYPE_ALL which is defined as 1 in mgntCtrl.h
# so that it can be used properly by the the PV  MGNT:LI21:1:ALLSWITCH
#
record(seq, "MGNT:DASEL:1:CTRLCLEAR") {
  field(DESC, "All function go")
  field(DOL1, "0")
  field(DOL2, "0")
  field(DOL3, "0")
  field(DOL4, "0")
  field(DOL5, "0")
  field(DOL6, "0")
  field(DOL7, "0")
  field(DOL8, "0")
  field(DOL9, "0")
  field(DOLA, "0")
  field(LNK1, "MGNT:DASEL:1:CTRL CA PP")
  field(LNK2, "MGNT:DASEL:1:BENDCTRL CA PP")
  field(LNK3, "MGNT:DASEL:1:BTRMCTRL CA PP")
  field(LNK4, "MGNT:DASEL:1:LGPSCTRL CA PP")
  field(LNK5, "MGNT:DASEL:1:QUADCTRL CA PP")
  field(LNK6, "MGNT:DASEL:1:XCORCTRL CA PP")
  field(LNK7, "MGNT:DASEL:1:YCORCTRL CA PP")
  field(LNK8, "MGNT:DASEL:1:SOLNCTRL CA PP")
  field(LNK9, "MGNT:DASEL:1:KICKCTRL CA PP")
  field(LNKA, "MGNT:DASEL:1:SEXTCTRL CA PP")
}

record(mbbo, "MGNT:DASEL:1:CTRL") {
  field(DESC, "All Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "1")
  field(FLNK, "MGNT:DASEL:1:ALLSWITCH")
}

record(seq, "MGNT:DASEL:1:ALLSWITCH") {
  field(DOL1, "MGNT:DASEL:1:CTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:ALLFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:CTRL")
}

record(bo, "MGNT:DASEL:1:ALLSTAR") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(PINI, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLSTARGO")
}

record(fanout, "MGNT:DASEL:1:ALLSTARGO") {
  field(LNK1, "MGNT:DASEL:1:ALLBENDSGO")
  field(LNK2, "MGNT:DASEL:1:ALLBTRMSGO")
  field(LNK3, "MGNT:DASEL:1:ALLLGPSSGO")
  field(LNK4, "MGNT:DASEL:1:ALLQUADSGO")
  field(LNK5, "MGNT:DASEL:1:ALLXCORSGO")
  field(LNK6, "MGNT:DASEL:1:ALLYCORSGO")
  field(FLNK, "MGNT:DASEL:1:ALLSTARGO_2")
}
record(fanout, "MGNT:DASEL:1:ALLSTARGO_2") {
  field(LNK1, "MGNT:DASEL:1:ALLSOLNSGO")
  field(LNK2, "MGNT:DASEL:1:ALLKICKSGO")
  field(LNK3, "MGNT:DASEL:1:ALLSEXTSGO")
}

#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BENDCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BEND so that it can be
# used properly by the the PV <device>:BENDSWITCH

record(mbbo, "MGNT:DASEL:1:BENDCTRL") {
  field(DESC, "All BEND Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "2")
  field(FLNK, "MGNT:DASEL:1:BENDSWITCH")
}

record(seq, "MGNT:DASEL:1:BENDSWITCH") {
  field(DOL1, "MGNT:DASEL:1:BENDCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:BENDFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:BENDCTRL")
}

record(seq, "MGNT:DASEL:1:ALLBENDSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLBENDS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLBENDS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLBENDSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:BENDCTRL",20,10,0,0,"MGNT:DASEL:1:BENDCTRL")
#! Field("MGNT:DASEL:1:BENDCTRL.FLNK",16777215,1,"MGNT:DASEL:1:BENDCTRL.FLNK")
#! Link("MGNT:DASEL:1:BENDCTRL.FLNK","MGNT:DASEL:1:BENDSWITCH")
#! Field("MGNT:DASEL:1:BENDCTRL.FFVL",16777215,1,"MGNT:DASEL:1:BENDCTRL.FFVL")
#! Record("MGNT:DASEL:1:BENDSWITCH",460,322,0,0,"MGNT:DASEL:1:BENDSWITCH")
#! Field("MGNT:DASEL:1:BENDSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:BENDSWITCH.DOL1")
#! Link("MGNT:DASEL:1:BENDSWITCH.DOL1","MGNT:DASEL:1:BENDCTRL.FFVL")
#! Field("MGNT:DASEL:1:BENDSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:BENDSWITCH.LNK1")
#! Field("MGNT:DASEL:1:BENDSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:BENDSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLBENDSGO",240,96,0,0,"MGNT:DASEL:1:ALLBENDSGO")
#! Field("MGNT:DASEL:1:ALLBENDSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLBENDSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLBENDSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLBENDSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLBENDSGO.LNK1","MGNT:DASEL:1:ALLBENDS.VAL")
#! Record("MGNT:DASEL:1:ALLBENDS",540,102,0,0,"MGNT:DASEL:1:ALLBENDS")
#! Field("MGNT:DASEL:1:ALLBENDS.VAL",16777215,0,"MGNT:DASEL:1:ALLBENDS.VAL")
#! Field("MGNT:DASEL:1:ALLBENDS.FLNK",16777215,1,"MGNT:DASEL:1:ALLBENDS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:BTRMCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_BTRM so that it can be
# used properly by the the PV <device>:BTRMSWITCH

record(mbbo, "MGNT:DASEL:1:BTRMCTRL") {
  field(DESC, "All BTRM Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DASEL:1:BTRMSWITCH")
}

record(seq, "MGNT:DASEL:1:BTRMSWITCH") {
  field(DOL1, "MGNT:DASEL:1:BTRMCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:BTRMFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:BTRMCTRL")
}

record(seq, "MGNT:DASEL:1:ALLBTRMSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLBTRMS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLBTRMS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLBTRMSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:BTRMCTRL",20,10,0,0,"MGNT:DASEL:1:BTRMCTRL")
#! Field("MGNT:DASEL:1:BTRMCTRL.FLNK",16777215,1,"MGNT:DASEL:1:BTRMCTRL.FLNK")
#! Link("MGNT:DASEL:1:BTRMCTRL.FLNK","MGNT:DASEL:1:BTRMSWITCH")
#! Field("MGNT:DASEL:1:BTRMCTRL.FFVL",16777215,1,"MGNT:DASEL:1:BTRMCTRL.FFVL")
#! Record("MGNT:DASEL:1:BTRMSWITCH",460,322,0,0,"MGNT:DASEL:1:BTRMSWITCH")
#! Field("MGNT:DASEL:1:BTRMSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:BTRMSWITCH.DOL1")
#! Link("MGNT:DASEL:1:BTRMSWITCH.DOL1","MGNT:DASEL:1:BTRMCTRL.FFVL")
#! Field("MGNT:DASEL:1:BTRMSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:BTRMSWITCH.LNK1")
#! Field("MGNT:DASEL:1:BTRMSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:BTRMSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLBTRMSGO",240,96,0,0,"MGNT:DASEL:1:ALLBTRMSGO")
#! Field("MGNT:DASEL:1:ALLBTRMSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLBTRMSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLBTRMSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLBTRMSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLBTRMSGO.LNK1","MGNT:DASEL:1:ALLBTRMS.VAL")
#! Record("MGNT:DASEL:1:ALLBTRMS",540,102,0,0,"MGNT:DASEL:1:ALLBTRMS")
#! Field("MGNT:DASEL:1:ALLBTRMS.VAL",16777215,0,"MGNT:DASEL:1:ALLBTRMS.VAL")
#! Field("MGNT:DASEL:1:ALLBTRMS.FLNK",16777215,1,"MGNT:DASEL:1:ALLBTRMS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:LGPSCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_LGPS so that it can be
# used properly by the the PV <device>:LGPSSWITCH

record(mbbo, "MGNT:DASEL:1:LGPSCTRL") {
  field(DESC, "All LGPS Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "3")
  field(FLNK, "MGNT:DASEL:1:LGPSSWITCH")
}

record(seq, "MGNT:DASEL:1:LGPSSWITCH") {
  field(DOL1, "MGNT:DASEL:1:LGPSCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:LGPSFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:LGPSCTRL")
}

record(seq, "MGNT:DASEL:1:ALLLGPSSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLLGPSS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLLGPSS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLLGPSSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:LGPSCTRL",20,10,0,0,"MGNT:DASEL:1:LGPSCTRL")
#! Field("MGNT:DASEL:1:LGPSCTRL.FLNK",16777215,1,"MGNT:DASEL:1:LGPSCTRL.FLNK")
#! Link("MGNT:DASEL:1:LGPSCTRL.FLNK","MGNT:DASEL:1:LGPSSWITCH")
#! Field("MGNT:DASEL:1:LGPSCTRL.FFVL",16777215,1,"MGNT:DASEL:1:LGPSCTRL.FFVL")
#! Record("MGNT:DASEL:1:LGPSSWITCH",460,322,0,0,"MGNT:DASEL:1:LGPSSWITCH")
#! Field("MGNT:DASEL:1:LGPSSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:LGPSSWITCH.DOL1")
#! Link("MGNT:DASEL:1:LGPSSWITCH.DOL1","MGNT:DASEL:1:LGPSCTRL.FFVL")
#! Field("MGNT:DASEL:1:LGPSSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:LGPSSWITCH.LNK1")
#! Field("MGNT:DASEL:1:LGPSSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:LGPSSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLLGPSSGO",240,96,0,0,"MGNT:DASEL:1:ALLLGPSSGO")
#! Field("MGNT:DASEL:1:ALLLGPSSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLLGPSSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLLGPSSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLLGPSSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLLGPSSGO.LNK1","MGNT:DASEL:1:ALLLGPSS.VAL")
#! Record("MGNT:DASEL:1:ALLLGPSS",540,102,0,0,"MGNT:DASEL:1:ALLLGPSS")
#! Field("MGNT:DASEL:1:ALLLGPSS.VAL",16777215,0,"MGNT:DASEL:1:ALLLGPSS.VAL")
#! Field("MGNT:DASEL:1:ALLLGPSS.FLNK",16777215,1,"MGNT:DASEL:1:ALLLGPSS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:QUADCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_QUAD so that it can be
# used properly by the the PV <device>:QUADSWITCH

record(mbbo, "MGNT:DASEL:1:QUADCTRL") {
  field(DESC, "All QUAD Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "5")
  field(FLNK, "MGNT:DASEL:1:QUADSWITCH")
}

record(seq, "MGNT:DASEL:1:QUADSWITCH") {
  field(DOL1, "MGNT:DASEL:1:QUADCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:QUADFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:QUADCTRL")
}

record(seq, "MGNT:DASEL:1:ALLQUADSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLQUADS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLQUADS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLQUADSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:QUADCTRL",20,10,0,0,"MGNT:DASEL:1:QUADCTRL")
#! Field("MGNT:DASEL:1:QUADCTRL.FLNK",16777215,1,"MGNT:DASEL:1:QUADCTRL.FLNK")
#! Link("MGNT:DASEL:1:QUADCTRL.FLNK","MGNT:DASEL:1:QUADSWITCH")
#! Field("MGNT:DASEL:1:QUADCTRL.FFVL",16777215,1,"MGNT:DASEL:1:QUADCTRL.FFVL")
#! Record("MGNT:DASEL:1:QUADSWITCH",460,322,0,0,"MGNT:DASEL:1:QUADSWITCH")
#! Field("MGNT:DASEL:1:QUADSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:QUADSWITCH.DOL1")
#! Link("MGNT:DASEL:1:QUADSWITCH.DOL1","MGNT:DASEL:1:QUADCTRL.FFVL")
#! Field("MGNT:DASEL:1:QUADSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:QUADSWITCH.LNK1")
#! Field("MGNT:DASEL:1:QUADSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:QUADSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLQUADSGO",240,96,0,0,"MGNT:DASEL:1:ALLQUADSGO")
#! Field("MGNT:DASEL:1:ALLQUADSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLQUADSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLQUADSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLQUADSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLQUADSGO.LNK1","MGNT:DASEL:1:ALLQUADS.VAL")
#! Record("MGNT:DASEL:1:ALLQUADS",540,102,0,0,"MGNT:DASEL:1:ALLQUADS")
#! Field("MGNT:DASEL:1:ALLQUADS.VAL",16777215,0,"MGNT:DASEL:1:ALLQUADS.VAL")
#! Field("MGNT:DASEL:1:ALLQUADS.FLNK",16777215,1,"MGNT:DASEL:1:ALLQUADS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:XCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_XCOR so that it can be
# used properly by the the PV <device>:XCORSWITCH

record(mbbo, "MGNT:DASEL:1:XCORCTRL") {
  field(DESC, "All XCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "6")
  field(FLNK, "MGNT:DASEL:1:XCORSWITCH")
}

record(seq, "MGNT:DASEL:1:XCORSWITCH") {
  field(DOL1, "MGNT:DASEL:1:XCORCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:XCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:XCORCTRL")
}

record(seq, "MGNT:DASEL:1:ALLXCORSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLXCORS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLXCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLXCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:XCORCTRL",20,10,0,0,"MGNT:DASEL:1:XCORCTRL")
#! Field("MGNT:DASEL:1:XCORCTRL.FLNK",16777215,1,"MGNT:DASEL:1:XCORCTRL.FLNK")
#! Link("MGNT:DASEL:1:XCORCTRL.FLNK","MGNT:DASEL:1:XCORSWITCH")
#! Field("MGNT:DASEL:1:XCORCTRL.FFVL",16777215,1,"MGNT:DASEL:1:XCORCTRL.FFVL")
#! Record("MGNT:DASEL:1:XCORSWITCH",460,322,0,0,"MGNT:DASEL:1:XCORSWITCH")
#! Field("MGNT:DASEL:1:XCORSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:XCORSWITCH.DOL1")
#! Link("MGNT:DASEL:1:XCORSWITCH.DOL1","MGNT:DASEL:1:XCORCTRL.FFVL")
#! Field("MGNT:DASEL:1:XCORSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:XCORSWITCH.LNK1")
#! Field("MGNT:DASEL:1:XCORSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:XCORSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLXCORSGO",240,96,0,0,"MGNT:DASEL:1:ALLXCORSGO")
#! Field("MGNT:DASEL:1:ALLXCORSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLXCORSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLXCORSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLXCORSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLXCORSGO.LNK1","MGNT:DASEL:1:ALLXCORS.VAL")
#! Record("MGNT:DASEL:1:ALLXCORS",540,102,0,0,"MGNT:DASEL:1:ALLXCORS")
#! Field("MGNT:DASEL:1:ALLXCORS.VAL",16777215,0,"MGNT:DASEL:1:ALLXCORS.VAL")
#! Field("MGNT:DASEL:1:ALLXCORS.FLNK",16777215,1,"MGNT:DASEL:1:ALLXCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:YCORCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_YCOR so that it can be
# used properly by the the PV <device>:YCORSWITCH

record(mbbo, "MGNT:DASEL:1:YCORCTRL") {
  field(DESC, "All YCOR Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "7")
  field(FLNK, "MGNT:DASEL:1:YCORSWITCH")
}

record(seq, "MGNT:DASEL:1:YCORSWITCH") {
  field(DOL1, "MGNT:DASEL:1:YCORCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:YCORFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:YCORCTRL")
}

record(seq, "MGNT:DASEL:1:ALLYCORSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLYCORS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLYCORS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLYCORSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:YCORCTRL",20,10,0,0,"MGNT:DASEL:1:YCORCTRL")
#! Field("MGNT:DASEL:1:YCORCTRL.FLNK",16777215,1,"MGNT:DASEL:1:YCORCTRL.FLNK")
#! Link("MGNT:DASEL:1:YCORCTRL.FLNK","MGNT:DASEL:1:YCORSWITCH")
#! Field("MGNT:DASEL:1:YCORCTRL.FFVL",16777215,1,"MGNT:DASEL:1:YCORCTRL.FFVL")
#! Record("MGNT:DASEL:1:YCORSWITCH",460,322,0,0,"MGNT:DASEL:1:YCORSWITCH")
#! Field("MGNT:DASEL:1:YCORSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:YCORSWITCH.DOL1")
#! Link("MGNT:DASEL:1:YCORSWITCH.DOL1","MGNT:DASEL:1:YCORCTRL.FFVL")
#! Field("MGNT:DASEL:1:YCORSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:YCORSWITCH.LNK1")
#! Field("MGNT:DASEL:1:YCORSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:YCORSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLYCORSGO",240,96,0,0,"MGNT:DASEL:1:ALLYCORSGO")
#! Field("MGNT:DASEL:1:ALLYCORSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLYCORSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLYCORSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLYCORSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLYCORSGO.LNK1","MGNT:DASEL:1:ALLYCORS.VAL")
#! Record("MGNT:DASEL:1:ALLYCORS",540,102,0,0,"MGNT:DASEL:1:ALLYCORS")
#! Field("MGNT:DASEL:1:ALLYCORS.VAL",16777215,0,"MGNT:DASEL:1:ALLYCORS.VAL")
#! Field("MGNT:DASEL:1:ALLYCORS.FLNK",16777215,1,"MGNT:DASEL:1:ALLYCORS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SOLNCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SOLN so that it can be
# used properly by the the PV <device>:SOLNSWITCH

record(mbbo, "MGNT:DASEL:1:SOLNCTRL") {
  field(DESC, "All SOLN Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "8")
  field(FLNK, "MGNT:DASEL:1:SOLNSWITCH")
}

record(seq, "MGNT:DASEL:1:SOLNSWITCH") {
  field(DOL1, "MGNT:DASEL:1:SOLNCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:SOLNFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:SOLNCTRL")
}

record(seq, "MGNT:DASEL:1:ALLSOLNSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLSOLNS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLSOLNS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLSOLNSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:SOLNCTRL",20,10,0,0,"MGNT:DASEL:1:SOLNCTRL")
#! Field("MGNT:DASEL:1:SOLNCTRL.FLNK",16777215,1,"MGNT:DASEL:1:SOLNCTRL.FLNK")
#! Link("MGNT:DASEL:1:SOLNCTRL.FLNK","MGNT:DASEL:1:SOLNSWITCH")
#! Field("MGNT:DASEL:1:SOLNCTRL.FFVL",16777215,1,"MGNT:DASEL:1:SOLNCTRL.FFVL")
#! Record("MGNT:DASEL:1:SOLNSWITCH",460,322,0,0,"MGNT:DASEL:1:SOLNSWITCH")
#! Field("MGNT:DASEL:1:SOLNSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:SOLNSWITCH.DOL1")
#! Link("MGNT:DASEL:1:SOLNSWITCH.DOL1","MGNT:DASEL:1:SOLNCTRL.FFVL")
#! Field("MGNT:DASEL:1:SOLNSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:SOLNSWITCH.LNK1")
#! Field("MGNT:DASEL:1:SOLNSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:SOLNSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLSOLNSGO",240,96,0,0,"MGNT:DASEL:1:ALLSOLNSGO")
#! Field("MGNT:DASEL:1:ALLSOLNSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLSOLNSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLSOLNSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLSOLNSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLSOLNSGO.LNK1","MGNT:DASEL:1:ALLSOLNS.VAL")
#! Record("MGNT:DASEL:1:ALLSOLNS",540,102,0,0,"MGNT:DASEL:1:ALLSOLNS")
#! Field("MGNT:DASEL:1:ALLSOLNS.VAL",16777215,0,"MGNT:DASEL:1:ALLSOLNS.VAL")
#! Field("MGNT:DASEL:1:ALLSOLNS.FLNK",16777215,1,"MGNT:DASEL:1:ALLSOLNS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:KICKCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_KICK so that it can be
# used properly by the the PV <device>:KICKSWITCH

record(mbbo, "MGNT:DASEL:1:KICKCTRL") {
  field(DESC, "All KICK Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "9")
  field(FLNK, "MGNT:DASEL:1:KICKSWITCH")
}

record(seq, "MGNT:DASEL:1:KICKSWITCH") {
  field(DOL1, "MGNT:DASEL:1:KICKCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:KICKFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:KICKCTRL")
}

record(seq, "MGNT:DASEL:1:ALLKICKSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLKICKS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLKICKS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLKICKSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:KICKCTRL",20,10,0,0,"MGNT:DASEL:1:KICKCTRL")
#! Field("MGNT:DASEL:1:KICKCTRL.FLNK",16777215,1,"MGNT:DASEL:1:KICKCTRL.FLNK")
#! Link("MGNT:DASEL:1:KICKCTRL.FLNK","MGNT:DASEL:1:KICKSWITCH")
#! Field("MGNT:DASEL:1:KICKCTRL.FFVL",16777215,1,"MGNT:DASEL:1:KICKCTRL.FFVL")
#! Record("MGNT:DASEL:1:KICKSWITCH",460,322,0,0,"MGNT:DASEL:1:KICKSWITCH")
#! Field("MGNT:DASEL:1:KICKSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:KICKSWITCH.DOL1")
#! Link("MGNT:DASEL:1:KICKSWITCH.DOL1","MGNT:DASEL:1:KICKCTRL.FFVL")
#! Field("MGNT:DASEL:1:KICKSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:KICKSWITCH.LNK1")
#! Field("MGNT:DASEL:1:KICKSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:KICKSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLKICKSGO",240,96,0,0,"MGNT:DASEL:1:ALLKICKSGO")
#! Field("MGNT:DASEL:1:ALLKICKSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLKICKSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLKICKSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLKICKSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLKICKSGO.LNK1","MGNT:DASEL:1:ALLKICKS.VAL")
#! Record("MGNT:DASEL:1:ALLKICKS",540,102,0,0,"MGNT:DASEL:1:ALLKICKS")
#! Field("MGNT:DASEL:1:ALLKICKS.VAL",16777215,0,"MGNT:DASEL:1:ALLKICKS.VAL")
#! Field("MGNT:DASEL:1:ALLKICKS.FLNK",16777215,1,"MGNT:DASEL:1:ALLKICKS.FLNK")
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# In the PV MGNT:<LOCA>:1:CTRLCLEAR LNK# (1-8)
# MUST corresponsds to the magent type defined
# in the file mgntCtrl.h.  Specifically,
# MGNT_TYPE_XCOR equals 6 and is LNK6
# in the above PV. Below in the pv <device>:SEXTCTRL
# the field FFVL value MUST be set to the value
# defined for MGNT_TYPE_SEXT so that it can be
# used properly by the the PV <device>:SEXTSWITCH

record(mbbo, "MGNT:DASEL:1:SEXTCTRL") {
  field(DESC, "All SEXT Function Control")
  field(PINI, "YES")
  field(DOL, "0")
  field(ZRST, "Ready")
  field(ONST, "TRIM")
  field(TWST, "PERTURB")
  field(THST, "BCON_TO_BDES")
  field(FRST, "BACT_TO_BDES")
  field(FVST, "SAVE_BDES")
  field(SXST, "LOAD_BDES")
  field(SVST, "UNDO_BDES")
  field(EIST, "DAC_ZERO")
  field(NIST, "STDZ")
  field(TEST, "CALIB")
  field(ELST, "DEGAUSS")
  field(TVST, "RESET")
  field(TTST, "TURN_ON")
  field(FTST, "TURN_OFF")
  field(ZRVL, "0")
  field(ONVL, "2")
  field(TWVL, "6")
  field(THVL, "15")
  field(FRVL, "14")
  field(FVVL, "11")
  field(SXVL, "12")
  field(SVVL, "13")
  field(EIVL, "7")
  field(NIVL, "4")
  field(TEVL, "3")
  field(ELVL, "5")
  field(TVVL, "8")
  field(TTVL, "9")
  field(FTVL, "10")
  field(FFVL, "10")
  field(FLNK, "MGNT:DASEL:1:SEXTSWITCH")
}

record(seq, "MGNT:DASEL:1:SEXTSWITCH") {
  field(DOL1, "MGNT:DASEL:1:SEXTCTRL.FFVL")
  field(LNK1, "MGNT:DASEL:1:CTRLSWITCH PP NMS")
  field(FLNK, "MGNT:DASEL:1:SEXTFUNCGO PP NMS")
  field(DISV, "0")
  field(SDIS, "MGNT:DASEL:1:SEXTCTRL")
}

record(seq, "MGNT:DASEL:1:ALLSEXTSGO") {
  field(DOL1, "MGNT:DASEL:1:ALLSTAR")
  field(LNK1, "MGNT:DASEL:1:ALLSEXTS PP NMS")
}

record(bo, "MGNT:DASEL:1:ALLSEXTS") {
  field(ZNAM, "NO")
  field(ONAM, "YES")
  field(FLNK, "MGNT:DASEL:1:ALLSEXTSSEL")
}

#! Further lines contain data used by VisualDCT
#! View(0,0,1.0)
#! Record("MGNT:DASEL:1:SEXTCTRL",20,10,0,0,"MGNT:DASEL:1:SEXTCTRL")
#! Field("MGNT:DASEL:1:SEXTCTRL.FLNK",16777215,1,"MGNT:DASEL:1:SEXTCTRL.FLNK")
#! Link("MGNT:DASEL:1:SEXTCTRL.FLNK","MGNT:DASEL:1:SEXTSWITCH")
#! Field("MGNT:DASEL:1:SEXTCTRL.FFVL",16777215,1,"MGNT:DASEL:1:SEXTCTRL.FFVL")
#! Record("MGNT:DASEL:1:SEXTSWITCH",460,322,0,0,"MGNT:DASEL:1:SEXTSWITCH")
#! Field("MGNT:DASEL:1:SEXTSWITCH.DOL1",16777215,0,"MGNT:DASEL:1:SEXTSWITCH.DOL1")
#! Link("MGNT:DASEL:1:SEXTSWITCH.DOL1","MGNT:DASEL:1:SEXTCTRL.FFVL")
#! Field("MGNT:DASEL:1:SEXTSWITCH.LNK1",16777215,1,"MGNT:DASEL:1:SEXTSWITCH.LNK1")
#! Field("MGNT:DASEL:1:SEXTSWITCH.FLNK",16777215,1,"MGNT:DASEL:1:SEXTSWITCH.FLNK")
#! Record("MGNT:DASEL:1:ALLSEXTSGO",240,96,0,0,"MGNT:DASEL:1:ALLSEXTSGO")
#! Field("MGNT:DASEL:1:ALLSEXTSGO.DOL1",16777215,1,"MGNT:DASEL:1:ALLSEXTSGO.DOL1")
#! Field("MGNT:DASEL:1:ALLSEXTSGO.LNK1",16777215,1,"MGNT:DASEL:1:ALLSEXTSGO.LNK1")
#! Link("MGNT:DASEL:1:ALLSEXTSGO.LNK1","MGNT:DASEL:1:ALLSEXTS.VAL")
#! Record("MGNT:DASEL:1:ALLSEXTS",540,102,0,0,"MGNT:DASEL:1:ALLSEXTS")
#! Field("MGNT:DASEL:1:ALLSEXTS.VAL",16777215,0,"MGNT:DASEL:1:ALLSEXTS.VAL")
#! Field("MGNT:DASEL:1:ALLSEXTS.FLNK",16777215,1,"MGNT:DASEL:1:ALLSEXTS.FLNK")
#! Generated by VisualDCT v2.6
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND


record(seq, "MGNT:DASEL:1:ALLSOLNSSEL") {
}

record(seq, "MGNT:DASEL:1:ALLKICKSSEL") {
  field(DOL1, "MGNT:DASEL:1:ALLKICKS")
  field(LNK1, "KICK:DASEL:105:SELECT CPP NMS")
}
record(seq, "MGNT:DASEL:1:ALLSEXTSSEL") {
}
record(seq, "MGNT:DASEL:1:ALLLGPSSSEL") {
  field(DOL1, "MGNT:DASEL:1:ALLLGPSS")
  field(LNK1, "LGPS:DASEL:1:SELECT CPP NMS")
}

record(seq, "MGNT:DASEL:1:ALLBENDSSEL") {
  field(DOL1, "MGNT:DASEL:1:ALLBENDS")
  field(DOL2, "MGNT:DASEL:1:ALLBENDS")
  field(DOL3, "MGNT:DASEL:1:ALLBENDS")
  field(DOL4, "MGNT:DASEL:1:ALLBENDS")
  field(LNK1, "BEND:DASEL:210:SELECT CPP NMS")
  field(LNK2, "BEND:DASEL:415:SELECT CPP NMS")
  field(LNK3, "BEND:DASEL:995:SELECT CPP NMS")
  field(LNK4, "BEND:BSYA:1000:SELECT CPP NMS")
}

record(seq, "MGNT:DASEL:1:ALLBTRMSSEL") {
}

record(seq, "MGNT:DASEL:1:ALLQUADSSEL") {
  field(DOL1, "MGNT:DASEL:1:ALLQUADS")
  field(DOL2, "MGNT:DASEL:1:ALLQUADS")
  field(DOL3, "MGNT:DASEL:1:ALLQUADS")
  field(DOL4, "MGNT:DASEL:1:ALLQUADS")
  field(DOL5, "MGNT:DASEL:1:ALLQUADS")
  field(DOL6, "MGNT:DASEL:1:ALLQUADS")
  field(DOL7, "MGNT:DASEL:1:ALLQUADS")
  field(DOL8, "MGNT:DASEL:1:ALLQUADS")
  field(DOL9, "MGNT:DASEL:1:ALLQUADS")
  field(LNK1, "QUAD:DASEL:300:SELECT CPP NMS")
  field(LNK2, "QUAD:DASEL:312:SELECT CPP NMS")
  field(LNK3, "QUAD:DASEL:434:SELECT CPP NMS")
  field(LNK4, "QUAD:DASEL:489:SELECT CPP NMS")
  field(LNK5, "QUAD:DASEL:557:SELECT CPP NMS")
  field(LNK6, "QUAD:DASEL:625:SELECT CPP NMS")
  field(LNK7, "QUAD:DASEL:822:SELECT CPP NMS")
  field(LNK8, "QUAD:DASEL:880:SELECT CPP NMS")
  field(LNK9, "QUAD:DASEL:910:SELECT CPP NMS")
}

record(seq, "MGNT:DASEL:1:ALLXCORSSEL") {
  field(DOL1, "MGNT:DASEL:1:ALLXCORS")
  field(DOL2, "MGNT:DASEL:1:ALLXCORS")
  field(DOL3, "MGNT:DASEL:1:ALLXCORS")
  field(DOL4, "MGNT:DASEL:1:ALLXCORS")
  field(LNK1, "XCOR:DASEL:294:SELECT CPP NMS")
  field(LNK2, "XCOR:DASEL:422:SELECT CPP NMS")
  field(LNK3, "XCOR:DASEL:622:SELECT CPP NMS")
  field(LNK4, "XCOR:DASEL:998:SELECT CPP NMS")
}

record(seq, "MGNT:DASEL:1:ALLYCORSSEL") {
  field(DOL1, "MGNT:DASEL:1:ALLYCORS")
  field(DOL2, "MGNT:DASEL:1:ALLYCORS")
  field(DOL3, "MGNT:DASEL:1:ALLYCORS")
  field(DOL4, "MGNT:DASEL:1:ALLYCORS")
  field(LNK1, "YCOR:DASEL:297:SELECT CPP NMS")
  field(LNK2, "YCOR:DASEL:423:SELECT CPP NMS")
  field(LNK3, "YCOR:DASEL:821:SELECT CPP NMS")
  field(LNK4, "YCOR:DASEL:999:SELECT CPP NMS")
}

record(seq, "MGNT:DASEL:1:ALLFUNCGO") {
  field(DESC, "Process CTRL func")
  field(DOL1, "0")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(DOL5, "1")
  field(DOL6, "1")
  field(DOL7, "1")
  field(LNK1, "MGNT:DASEL:1:CTRLCLEAR.DISV")
  field(LNK2, "MGNT:DASEL:1:BENDFUNCGO.PROC")
  field(LNK3, "MGNT:DASEL:1:BTRMFUNCGO.PROC")
  field(LNK4, "MGNT:DASEL:1:QUADFUNCGO.PROC")
  field(LNK5, "MGNT:DASEL:1:XCORFUNCGO.PROC")
  field(LNK6, "MGNT:DASEL:1:YCORFUNCGO.PROC")
  field(LNK7, "MGNT:DASEL:1:LGPSFUNCGO.PROC")
  field(FLNK, "MGNT:DASEL:1:ALLFUNCGO2")
}
record(seq, "MGNT:DASEL:1:ALLFUNCGO2") {
  field(DESC, "Process CTRL func")
  field(DOL1, "1")
  field(DOL2, "1")
  field(DOL3, "1")
  field(DOL4, "1")
  field(LNK1, "MGNT:DASEL:1:SOLNFUNCGO.PROC")
  field(LNK2, "MGNT:DASEL:1:KICKFUNCGO.PROC")
  field(LNK3, "MGNT:DASEL:1:SEXTFUNCGO.PROC")
  field(LNK4, "MGNT:DASEL:1:CTRLCLEAR.DISV")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:SOLNFUNCGO") {
  field(DESC, "Process SOLN CTRL func")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}
record(fanout, "MGNT:DASEL:1:KICKFUNCGO") {
  field(DESC, "Process KICK CTRL func")
  field(LNK1, "KICK:DASEL:105:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}
record(fanout, "MGNT:DASEL:1:SEXTFUNCGO") {
  field(DESC, "Process SEXT CTRL func")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:BENDFUNCGO") {
  field(DESC, "Process BEND CTRL func")
  field(LNK1, "BEND:DASEL:210:ALLFUNCGO")
  field(LNK2, "BEND:DASEL:415:ALLFUNCGO")
  field(LNK3, "BEND:DASEL:995:ALLFUNCGO")
  field(LNK3, "BEND:BSYA:1000:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:BTRMFUNCGO") {
  field(DESC, "Process BTRM CTRL func")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:QUADFUNCGO") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:DASEL:300:ALLFUNCGO")
  field(LNK2, "QUAD:DASEL:312:ALLFUNCGO")
  field(LNK3, "QUAD:DASEL:434:ALLFUNCGO")
  field(LNK4, "QUAD:DASEL:489:ALLFUNCGO")
  field(LNK5, "QUAD:DASEL:557:ALLFUNCGO")
  field(LNK6, "QUAD:DASEL:625:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:QUADFUNCGO_2")
}
record(fanout, "MGNT:DASEL:1:QUADFUNCGO_2") {
  field(DESC, "Process QUAD CTRL func")
  field(LNK1, "QUAD:DASEL:822:ALLFUNCGO")
  field(LNK2, "QUAD:DASEL:880:ALLFUNCGO")
  field(LNK3, "QUAD:DASEL:910:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:XCORFUNCGO") {
  field(DESC, "Process XCOR CTRL func")
  field(LNK1, "XCOR:DASEL:294:ALLFUNCGO")
  field(LNK2, "XCOR:DASEL:422:ALLFUNCGO")
  field(LNK3, "XCOR:DASEL:622:ALLFUNCGO")
  field(LNK4, "XCOR:DASEL:998:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:YCORFUNCGO") {
  field(DESC, "Process YCOR CTRL func")
  field(LNK1, "YCOR:DASEL:297:ALLFUNCGO")
  field(LNK2, "YCOR:DASEL:423:ALLFUNCGO")
  field(LNK3, "YCOR:DASEL:821:ALLFUNCGO")
  field(LNK4, "YCOR:DASEL:999:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}

record(fanout, "MGNT:DASEL:1:LGPSFUNCGO") {
  field(DESC, "Process LGPS CTRL func")
  field(LNK1, "LGPS:DASEL:1:ALLFUNCGO")
  field(FLNK, "MGNT:DASEL:1:CTRLCLEAR")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "LGPS:DASEL:1:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "LGPS:DASEL:1:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "LGPS:DASEL:1:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "LGPS:DASEL:1:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "LGPS:DASEL:1:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "LGPS:DASEL:1:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "LGPS:DASEL:1:EDES.PROC PP")
    field(LNK2, "LGPS:DASEL:1:EACT.PROC PP")
    field(LNK3, "LGPS:DASEL:1:EERR.DISA PP")
    field(LNK4, "LGPS:DASEL:1:ECON.PROC PP")
    field(LNK5, "LGPS:DASEL:1:BMAGX.PROC PP")
    field(LNK6, "LGPS:DASEL:1:BMAGY.PROC PP")
    field(LNK7, "LGPS:DASEL:1:BLEM.PROC PP")
    field(LNK8, "LGPS:DASEL:1:BMOD.PROC PP")
    field(LNK9, "LGPS:DASEL:1:EDESSAVE.PROC PP")
    field(LNKA, "LGPS:DASEL:1:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"LGPS:DASEL:1:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "LGPS:DASEL:1:BMAX")
  field(DOL2, "LGPS:DASEL:1:BMAX")
  field(DOL3, "LGPS:DASEL:1:BMAX")
  field(DOL4, "LGPS:DASEL:1:BMIN")
  field(DOL5, "LGPS:DASEL:1:BMIN")
  field(DOL6, "LGPS:DASEL:1:BMIN")
  field(LNK1, "LGPS:DASEL:1:BMAGX.HOPR")
  field(LNK2, "LGPS:DASEL:1:BMAGY.HOPR")
  field(LNK3, "LGPS:DASEL:1:BLEM.HOPR")
  field(LNK4, "LGPS:DASEL:1:BMAGX.LOPR PP")
  field(LNK5, "LGPS:DASEL:1:BMAGY.LOPR PP")
  field(LNK6, "LGPS:DASEL:1:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "LGPS:DASEL:1:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "LGPS:DASEL:1:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "LGPS:DASEL:1:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "LGPS:DASEL:1:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "V")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "LGPS:DASEL:1:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:DASEL:1:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:DASEL:1:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:DASEL:1:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "LGPS:DASEL:1:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "LGPS:DASEL:1:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "LGPS:DASEL:1:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "LGPS:DASEL:1:EDES NPP MS")
  field(INPB, "LGPS:DASEL:1:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DASEL:210:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "BEND:DASEL:210:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DASEL:210:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DASEL:210:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DASEL:210:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DASEL:210:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DASEL:210:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DASEL:210:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DASEL:210:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DASEL:210:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DASEL:210:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DASEL:210:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DASEL:210:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DASEL:210:EDES.PROC PP")
    field(LNK2, "BEND:DASEL:210:EACT.PROC PP")
    field(LNK3, "BEND:DASEL:210:EERR.DISA PP")
    field(LNK4, "BEND:DASEL:210:ECON.PROC PP")
    field(LNK5, "BEND:DASEL:210:BMAGX.PROC PP")
    field(LNK6, "BEND:DASEL:210:BMAGY.PROC PP")
    field(LNK7, "BEND:DASEL:210:BLEM.PROC PP")
    field(LNK8, "BEND:DASEL:210:BMOD.PROC PP")
    field(LNK9, "BEND:DASEL:210:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DASEL:210:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DASEL:210:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DASEL:210:BMAX")
  field(DOL2, "BEND:DASEL:210:BMAX")
  field(DOL3, "BEND:DASEL:210:BMAX")
  field(DOL4, "BEND:DASEL:210:BMIN")
  field(DOL5, "BEND:DASEL:210:BMIN")
  field(DOL6, "BEND:DASEL:210:BMIN")
  field(LNK1, "BEND:DASEL:210:BMAGX.HOPR")
  field(LNK2, "BEND:DASEL:210:BMAGY.HOPR")
  field(LNK3, "BEND:DASEL:210:BLEM.HOPR")
  field(LNK4, "BEND:DASEL:210:BMAGX.LOPR PP")
  field(LNK5, "BEND:DASEL:210:BMAGY.LOPR PP")
  field(LNK6, "BEND:DASEL:210:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DASEL:210:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DASEL:210:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DASEL:210:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DASEL:210:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DASEL:210:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:210:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:210:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DASEL:210:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:210:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DASEL:210:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DASEL:210:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DASEL:210:EDES NPP MS")
  field(INPB, "BEND:DASEL:210:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DASEL:415:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "BEND:DASEL:415:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DASEL:415:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DASEL:415:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DASEL:415:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DASEL:415:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DASEL:415:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DASEL:415:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DASEL:415:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DASEL:415:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DASEL:415:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DASEL:415:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DASEL:415:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DASEL:415:EDES.PROC PP")
    field(LNK2, "BEND:DASEL:415:EACT.PROC PP")
    field(LNK3, "BEND:DASEL:415:EERR.DISA PP")
    field(LNK4, "BEND:DASEL:415:ECON.PROC PP")
    field(LNK5, "BEND:DASEL:415:BMAGX.PROC PP")
    field(LNK6, "BEND:DASEL:415:BMAGY.PROC PP")
    field(LNK7, "BEND:DASEL:415:BLEM.PROC PP")
    field(LNK8, "BEND:DASEL:415:BMOD.PROC PP")
    field(LNK9, "BEND:DASEL:415:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DASEL:415:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DASEL:415:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DASEL:415:BMAX")
  field(DOL2, "BEND:DASEL:415:BMAX")
  field(DOL3, "BEND:DASEL:415:BMAX")
  field(DOL4, "BEND:DASEL:415:BMIN")
  field(DOL5, "BEND:DASEL:415:BMIN")
  field(DOL6, "BEND:DASEL:415:BMIN")
  field(LNK1, "BEND:DASEL:415:BMAGX.HOPR")
  field(LNK2, "BEND:DASEL:415:BMAGY.HOPR")
  field(LNK3, "BEND:DASEL:415:BLEM.HOPR")
  field(LNK4, "BEND:DASEL:415:BMAGX.LOPR PP")
  field(LNK5, "BEND:DASEL:415:BMAGY.LOPR PP")
  field(LNK6, "BEND:DASEL:415:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DASEL:415:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DASEL:415:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DASEL:415:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DASEL:415:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DASEL:415:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:415:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:415:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DASEL:415:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:415:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DASEL:415:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DASEL:415:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DASEL:415:EDES NPP MS")
  field(INPB, "BEND:DASEL:415:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:DASEL:995:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "BEND:DASEL:995:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:DASEL:995:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:DASEL:995:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:DASEL:995:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:DASEL:995:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:DASEL:995:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:DASEL:995:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:DASEL:995:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:DASEL:995:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:DASEL:995:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:DASEL:995:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:DASEL:995:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:DASEL:995:EDES.PROC PP")
    field(LNK2, "BEND:DASEL:995:EACT.PROC PP")
    field(LNK3, "BEND:DASEL:995:EERR.DISA PP")
    field(LNK4, "BEND:DASEL:995:ECON.PROC PP")
    field(LNK5, "BEND:DASEL:995:BMAGX.PROC PP")
    field(LNK6, "BEND:DASEL:995:BMAGY.PROC PP")
    field(LNK7, "BEND:DASEL:995:BLEM.PROC PP")
    field(LNK8, "BEND:DASEL:995:BMOD.PROC PP")
    field(LNK9, "BEND:DASEL:995:EDESSAVE.PROC PP")
    field(LNKA, "BEND:DASEL:995:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:DASEL:995:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:DASEL:995:BMAX")
  field(DOL2, "BEND:DASEL:995:BMAX")
  field(DOL3, "BEND:DASEL:995:BMAX")
  field(DOL4, "BEND:DASEL:995:BMIN")
  field(DOL5, "BEND:DASEL:995:BMIN")
  field(DOL6, "BEND:DASEL:995:BMIN")
  field(LNK1, "BEND:DASEL:995:BMAGX.HOPR")
  field(LNK2, "BEND:DASEL:995:BMAGY.HOPR")
  field(LNK3, "BEND:DASEL:995:BLEM.HOPR")
  field(LNK4, "BEND:DASEL:995:BMAGX.LOPR PP")
  field(LNK5, "BEND:DASEL:995:BMAGY.LOPR PP")
  field(LNK6, "BEND:DASEL:995:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:DASEL:995:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:DASEL:995:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:DASEL:995:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:DASEL:995:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:DASEL:995:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:995:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:995:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DASEL:995:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:DASEL:995:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:DASEL:995:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:DASEL:995:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:DASEL:995:EDES NPP MS")
  field(INPB, "BEND:DASEL:995:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DASEL:105:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "KICK:DASEL:105:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DASEL:105:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DASEL:105:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DASEL:105:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DASEL:105:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DASEL:105:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DASEL:105:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DASEL:105:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DASEL:105:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DASEL:105:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DASEL:105:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DASEL:105:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DASEL:105:EDES.PROC PP")
    field(LNK2, "KICK:DASEL:105:EACT.PROC PP")
    field(LNK3, "KICK:DASEL:105:EERR.DISA PP")
    field(LNK4, "KICK:DASEL:105:ECON.PROC PP")
    field(LNK5, "KICK:DASEL:105:BMAGX.PROC PP")
    field(LNK6, "KICK:DASEL:105:BMAGY.PROC PP")
    field(LNK7, "KICK:DASEL:105:BLEM.PROC PP")
    field(LNK8, "KICK:DASEL:105:BMOD.PROC PP")
    field(LNK9, "KICK:DASEL:105:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DASEL:105:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DASEL:105:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DASEL:105:BMAX")
  field(DOL2, "KICK:DASEL:105:BMAX")
  field(DOL3, "KICK:DASEL:105:BMAX")
  field(DOL4, "KICK:DASEL:105:BMIN")
  field(DOL5, "KICK:DASEL:105:BMIN")
  field(DOL6, "KICK:DASEL:105:BMIN")
  field(LNK1, "KICK:DASEL:105:BMAGX.HOPR")
  field(LNK2, "KICK:DASEL:105:BMAGY.HOPR")
  field(LNK3, "KICK:DASEL:105:BLEM.HOPR")
  field(LNK4, "KICK:DASEL:105:BMAGX.LOPR PP")
  field(LNK5, "KICK:DASEL:105:BMAGY.LOPR PP")
  field(LNK6, "KICK:DASEL:105:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:105:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:105:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DASEL:105:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DASEL:105:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DASEL:105:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:105:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:105:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:DASEL:105:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:105:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "KICK:DASEL:105:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DASEL:105:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DASEL:105:EDES NPP MS")
  field(INPB, "KICK:DASEL:105:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:300:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:300:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:300:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:300:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:300:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:300:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:300:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:300:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:300:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:300:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:300:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:300:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:300:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:300:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:300:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:300:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:300:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:300:BMAX")
  field(DOL2, "QUAD:DASEL:300:BMAX")
  field(DOL3, "QUAD:DASEL:300:BMAX")
  field(DOL4, "QUAD:DASEL:300:BMIN")
  field(DOL5, "QUAD:DASEL:300:BMIN")
  field(DOL6, "QUAD:DASEL:300:BMIN")
  field(LNK1, "QUAD:DASEL:300:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:300:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:300:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:300:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:300:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:300:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:300:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:300:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:300:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:300:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:300:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:300:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:300:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:300:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:300:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:300:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:300:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:300:EDES NPP MS")
  field(INPB, "QUAD:DASEL:300:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:312:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:312:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:312:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:312:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:312:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:312:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:312:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:312:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:312:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:312:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:312:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:312:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:312:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:312:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:312:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:312:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:312:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:312:BMAX")
  field(DOL2, "QUAD:DASEL:312:BMAX")
  field(DOL3, "QUAD:DASEL:312:BMAX")
  field(DOL4, "QUAD:DASEL:312:BMIN")
  field(DOL5, "QUAD:DASEL:312:BMIN")
  field(DOL6, "QUAD:DASEL:312:BMIN")
  field(LNK1, "QUAD:DASEL:312:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:312:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:312:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:312:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:312:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:312:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:312:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:312:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:312:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:312:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:312:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:312:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:312:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:312:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:312:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:312:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:312:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:312:EDES NPP MS")
  field(INPB, "QUAD:DASEL:312:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:434:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:434:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:434:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:434:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:434:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:434:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:434:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:434:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:434:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:434:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:434:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:434:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:434:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:434:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:434:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:434:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:434:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:434:BMAX")
  field(DOL2, "QUAD:DASEL:434:BMAX")
  field(DOL3, "QUAD:DASEL:434:BMAX")
  field(DOL4, "QUAD:DASEL:434:BMIN")
  field(DOL5, "QUAD:DASEL:434:BMIN")
  field(DOL6, "QUAD:DASEL:434:BMIN")
  field(LNK1, "QUAD:DASEL:434:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:434:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:434:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:434:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:434:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:434:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:434:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:434:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:434:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:434:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:434:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:434:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:434:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:434:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:434:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:434:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:434:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:434:EDES NPP MS")
  field(INPB, "QUAD:DASEL:434:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:489:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:489:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:489:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:489:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:489:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:489:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:489:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:489:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:489:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:489:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:489:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:489:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:489:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:489:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:489:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:489:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:489:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:489:BMAX")
  field(DOL2, "QUAD:DASEL:489:BMAX")
  field(DOL3, "QUAD:DASEL:489:BMAX")
  field(DOL4, "QUAD:DASEL:489:BMIN")
  field(DOL5, "QUAD:DASEL:489:BMIN")
  field(DOL6, "QUAD:DASEL:489:BMIN")
  field(LNK1, "QUAD:DASEL:489:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:489:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:489:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:489:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:489:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:489:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:489:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:489:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:489:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:489:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:489:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:489:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:489:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:489:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:489:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:489:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:489:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:489:EDES NPP MS")
  field(INPB, "QUAD:DASEL:489:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:557:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:557:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:557:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:557:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:557:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:557:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:557:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:557:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:557:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:557:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:557:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:557:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:557:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:557:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:557:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:557:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:557:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:557:BMAX")
  field(DOL2, "QUAD:DASEL:557:BMAX")
  field(DOL3, "QUAD:DASEL:557:BMAX")
  field(DOL4, "QUAD:DASEL:557:BMIN")
  field(DOL5, "QUAD:DASEL:557:BMIN")
  field(DOL6, "QUAD:DASEL:557:BMIN")
  field(LNK1, "QUAD:DASEL:557:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:557:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:557:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:557:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:557:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:557:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:557:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:557:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:557:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:557:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:557:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:557:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:557:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:557:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:557:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:557:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:557:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:557:EDES NPP MS")
  field(INPB, "QUAD:DASEL:557:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:625:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:625:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:625:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:625:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:625:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:625:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:625:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:625:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:625:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:625:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:625:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:625:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:625:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:625:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:625:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:625:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:625:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:625:BMAX")
  field(DOL2, "QUAD:DASEL:625:BMAX")
  field(DOL3, "QUAD:DASEL:625:BMAX")
  field(DOL4, "QUAD:DASEL:625:BMIN")
  field(DOL5, "QUAD:DASEL:625:BMIN")
  field(DOL6, "QUAD:DASEL:625:BMIN")
  field(LNK1, "QUAD:DASEL:625:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:625:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:625:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:625:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:625:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:625:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:625:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:625:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:625:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:625:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:625:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:625:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:625:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:625:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:625:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:625:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:625:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:625:EDES NPP MS")
  field(INPB, "QUAD:DASEL:625:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:822:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:822:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:822:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:822:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:822:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:822:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:822:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:822:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:822:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:822:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:822:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:822:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:822:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:822:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:822:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:822:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:822:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:822:BMAX")
  field(DOL2, "QUAD:DASEL:822:BMAX")
  field(DOL3, "QUAD:DASEL:822:BMAX")
  field(DOL4, "QUAD:DASEL:822:BMIN")
  field(DOL5, "QUAD:DASEL:822:BMIN")
  field(DOL6, "QUAD:DASEL:822:BMIN")
  field(LNK1, "QUAD:DASEL:822:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:822:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:822:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:822:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:822:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:822:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:822:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:822:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:822:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:822:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:822:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:822:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:822:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:822:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:822:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:822:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:822:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:822:EDES NPP MS")
  field(INPB, "QUAD:DASEL:822:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:880:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:880:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:880:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:880:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:880:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:880:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:880:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:880:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:880:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:880:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:880:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:880:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:880:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:880:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:880:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:880:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:880:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:880:BMAX")
  field(DOL2, "QUAD:DASEL:880:BMAX")
  field(DOL3, "QUAD:DASEL:880:BMAX")
  field(DOL4, "QUAD:DASEL:880:BMIN")
  field(DOL5, "QUAD:DASEL:880:BMIN")
  field(DOL6, "QUAD:DASEL:880:BMIN")
  field(LNK1, "QUAD:DASEL:880:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:880:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:880:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:880:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:880:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:880:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:880:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:880:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:880:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:880:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:880:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:880:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:880:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:880:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:880:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:880:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:880:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:880:EDES NPP MS")
  field(INPB, "QUAD:DASEL:880:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:910:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:910:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:910:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:910:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:910:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:910:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:910:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:910:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:910:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:910:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:910:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:910:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:910:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:910:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:910:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:910:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:910:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:910:BMAX")
  field(DOL2, "QUAD:DASEL:910:BMAX")
  field(DOL3, "QUAD:DASEL:910:BMAX")
  field(DOL4, "QUAD:DASEL:910:BMIN")
  field(DOL5, "QUAD:DASEL:910:BMIN")
  field(DOL6, "QUAD:DASEL:910:BMIN")
  field(LNK1, "QUAD:DASEL:910:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:910:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:910:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:910:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:910:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:910:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:910:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:910:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:910:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:910:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:910:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:910:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:910:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:910:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:910:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "QUAD:DASEL:910:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:910:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:910:EDES NPP MS")
  field(INPB, "QUAD:DASEL:910:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DASEL:294:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DASEL:294:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DASEL:294:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DASEL:294:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DASEL:294:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DASEL:294:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DASEL:294:EDES.PROC PP")
    field(LNK2, "XCOR:DASEL:294:EACT.PROC PP")
    field(LNK3, "XCOR:DASEL:294:EERR.DISA PP")
    field(LNK4, "XCOR:DASEL:294:ECON.PROC PP")
    field(LNK5, "XCOR:DASEL:294:BMAGX.PROC PP")
    field(LNK6, "XCOR:DASEL:294:BMAGY.PROC PP")
    field(LNK7, "XCOR:DASEL:294:BLEM.PROC PP")
    field(LNK8, "XCOR:DASEL:294:BMOD.PROC PP")
    field(LNK9, "XCOR:DASEL:294:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DASEL:294:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DASEL:294:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DASEL:294:BMAX")
  field(DOL2, "XCOR:DASEL:294:BMAX")
  field(DOL3, "XCOR:DASEL:294:BMAX")
  field(DOL4, "XCOR:DASEL:294:BMIN")
  field(DOL5, "XCOR:DASEL:294:BMIN")
  field(DOL6, "XCOR:DASEL:294:BMIN")
  field(LNK1, "XCOR:DASEL:294:BMAGX.HOPR")
  field(LNK2, "XCOR:DASEL:294:BMAGY.HOPR")
  field(LNK3, "XCOR:DASEL:294:BLEM.HOPR")
  field(LNK4, "XCOR:DASEL:294:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DASEL:294:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DASEL:294:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:294:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:294:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DASEL:294:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DASEL:294:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DASEL:294:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:294:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:294:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:294:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:294:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:294:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DASEL:294:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DASEL:294:EDES NPP MS")
  field(INPB, "XCOR:DASEL:294:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DASEL:422:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DASEL:422:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DASEL:422:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DASEL:422:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DASEL:422:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DASEL:422:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DASEL:422:EDES.PROC PP")
    field(LNK2, "XCOR:DASEL:422:EACT.PROC PP")
    field(LNK3, "XCOR:DASEL:422:EERR.DISA PP")
    field(LNK4, "XCOR:DASEL:422:ECON.PROC PP")
    field(LNK5, "XCOR:DASEL:422:BMAGX.PROC PP")
    field(LNK6, "XCOR:DASEL:422:BMAGY.PROC PP")
    field(LNK7, "XCOR:DASEL:422:BLEM.PROC PP")
    field(LNK8, "XCOR:DASEL:422:BMOD.PROC PP")
    field(LNK9, "XCOR:DASEL:422:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DASEL:422:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DASEL:422:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DASEL:422:BMAX")
  field(DOL2, "XCOR:DASEL:422:BMAX")
  field(DOL3, "XCOR:DASEL:422:BMAX")
  field(DOL4, "XCOR:DASEL:422:BMIN")
  field(DOL5, "XCOR:DASEL:422:BMIN")
  field(DOL6, "XCOR:DASEL:422:BMIN")
  field(LNK1, "XCOR:DASEL:422:BMAGX.HOPR")
  field(LNK2, "XCOR:DASEL:422:BMAGY.HOPR")
  field(LNK3, "XCOR:DASEL:422:BLEM.HOPR")
  field(LNK4, "XCOR:DASEL:422:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DASEL:422:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DASEL:422:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:422:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:422:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DASEL:422:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DASEL:422:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DASEL:422:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:422:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:422:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:422:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:422:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:422:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DASEL:422:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DASEL:422:EDES NPP MS")
  field(INPB, "XCOR:DASEL:422:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DASEL:622:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DASEL:622:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DASEL:622:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DASEL:622:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DASEL:622:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DASEL:622:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DASEL:622:EDES.PROC PP")
    field(LNK2, "XCOR:DASEL:622:EACT.PROC PP")
    field(LNK3, "XCOR:DASEL:622:EERR.DISA PP")
    field(LNK4, "XCOR:DASEL:622:ECON.PROC PP")
    field(LNK5, "XCOR:DASEL:622:BMAGX.PROC PP")
    field(LNK6, "XCOR:DASEL:622:BMAGY.PROC PP")
    field(LNK7, "XCOR:DASEL:622:BLEM.PROC PP")
    field(LNK8, "XCOR:DASEL:622:BMOD.PROC PP")
    field(LNK9, "XCOR:DASEL:622:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DASEL:622:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DASEL:622:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DASEL:622:BMAX")
  field(DOL2, "XCOR:DASEL:622:BMAX")
  field(DOL3, "XCOR:DASEL:622:BMAX")
  field(DOL4, "XCOR:DASEL:622:BMIN")
  field(DOL5, "XCOR:DASEL:622:BMIN")
  field(DOL6, "XCOR:DASEL:622:BMIN")
  field(LNK1, "XCOR:DASEL:622:BMAGX.HOPR")
  field(LNK2, "XCOR:DASEL:622:BMAGY.HOPR")
  field(LNK3, "XCOR:DASEL:622:BLEM.HOPR")
  field(LNK4, "XCOR:DASEL:622:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DASEL:622:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DASEL:622:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:622:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:622:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DASEL:622:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DASEL:622:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DASEL:622:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:622:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:622:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:622:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:622:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:622:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DASEL:622:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DASEL:622:EDES NPP MS")
  field(INPB, "XCOR:DASEL:622:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "XCOR:DASEL:998:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "XCOR:DASEL:998:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "XCOR:DASEL:998:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "XCOR:DASEL:998:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "XCOR:DASEL:998:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "XCOR:DASEL:998:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "XCOR:DASEL:998:EDES.PROC PP")
    field(LNK2, "XCOR:DASEL:998:EACT.PROC PP")
    field(LNK3, "XCOR:DASEL:998:EERR.DISA PP")
    field(LNK4, "XCOR:DASEL:998:ECON.PROC PP")
    field(LNK5, "XCOR:DASEL:998:BMAGX.PROC PP")
    field(LNK6, "XCOR:DASEL:998:BMAGY.PROC PP")
    field(LNK7, "XCOR:DASEL:998:BLEM.PROC PP")
    field(LNK8, "XCOR:DASEL:998:BMOD.PROC PP")
    field(LNK9, "XCOR:DASEL:998:EDESSAVE.PROC PP")
    field(LNKA, "XCOR:DASEL:998:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"XCOR:DASEL:998:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "XCOR:DASEL:998:BMAX")
  field(DOL2, "XCOR:DASEL:998:BMAX")
  field(DOL3, "XCOR:DASEL:998:BMAX")
  field(DOL4, "XCOR:DASEL:998:BMIN")
  field(DOL5, "XCOR:DASEL:998:BMIN")
  field(DOL6, "XCOR:DASEL:998:BMIN")
  field(LNK1, "XCOR:DASEL:998:BMAGX.HOPR")
  field(LNK2, "XCOR:DASEL:998:BMAGY.HOPR")
  field(LNK3, "XCOR:DASEL:998:BLEM.HOPR")
  field(LNK4, "XCOR:DASEL:998:BMAGX.LOPR PP")
  field(LNK5, "XCOR:DASEL:998:BMAGY.LOPR PP")
  field(LNK6, "XCOR:DASEL:998:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:998:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "XCOR:DASEL:998:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "XCOR:DASEL:998:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "XCOR:DASEL:998:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "XCOR:DASEL:998:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:998:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:998:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:998:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "XCOR:DASEL:998:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "XCOR:DASEL:998:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "XCOR:DASEL:998:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "XCOR:DASEL:998:EDES NPP MS")
  field(INPB, "XCOR:DASEL:998:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DASEL:297:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DASEL:297:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DASEL:297:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DASEL:297:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DASEL:297:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DASEL:297:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DASEL:297:EDES.PROC PP")
    field(LNK2, "YCOR:DASEL:297:EACT.PROC PP")
    field(LNK3, "YCOR:DASEL:297:EERR.DISA PP")
    field(LNK4, "YCOR:DASEL:297:ECON.PROC PP")
    field(LNK5, "YCOR:DASEL:297:BMAGX.PROC PP")
    field(LNK6, "YCOR:DASEL:297:BMAGY.PROC PP")
    field(LNK7, "YCOR:DASEL:297:BLEM.PROC PP")
    field(LNK8, "YCOR:DASEL:297:BMOD.PROC PP")
    field(LNK9, "YCOR:DASEL:297:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DASEL:297:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DASEL:297:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DASEL:297:BMAX")
  field(DOL2, "YCOR:DASEL:297:BMAX")
  field(DOL3, "YCOR:DASEL:297:BMAX")
  field(DOL4, "YCOR:DASEL:297:BMIN")
  field(DOL5, "YCOR:DASEL:297:BMIN")
  field(DOL6, "YCOR:DASEL:297:BMIN")
  field(LNK1, "YCOR:DASEL:297:BMAGX.HOPR")
  field(LNK2, "YCOR:DASEL:297:BMAGY.HOPR")
  field(LNK3, "YCOR:DASEL:297:BLEM.HOPR")
  field(LNK4, "YCOR:DASEL:297:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DASEL:297:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DASEL:297:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:297:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:297:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DASEL:297:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DASEL:297:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DASEL:297:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:297:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:297:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:297:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:297:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:297:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DASEL:297:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DASEL:297:EDES NPP MS")
  field(INPB, "YCOR:DASEL:297:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DASEL:423:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DASEL:423:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DASEL:423:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DASEL:423:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DASEL:423:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DASEL:423:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DASEL:423:EDES.PROC PP")
    field(LNK2, "YCOR:DASEL:423:EACT.PROC PP")
    field(LNK3, "YCOR:DASEL:423:EERR.DISA PP")
    field(LNK4, "YCOR:DASEL:423:ECON.PROC PP")
    field(LNK5, "YCOR:DASEL:423:BMAGX.PROC PP")
    field(LNK6, "YCOR:DASEL:423:BMAGY.PROC PP")
    field(LNK7, "YCOR:DASEL:423:BLEM.PROC PP")
    field(LNK8, "YCOR:DASEL:423:BMOD.PROC PP")
    field(LNK9, "YCOR:DASEL:423:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DASEL:423:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DASEL:423:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DASEL:423:BMAX")
  field(DOL2, "YCOR:DASEL:423:BMAX")
  field(DOL3, "YCOR:DASEL:423:BMAX")
  field(DOL4, "YCOR:DASEL:423:BMIN")
  field(DOL5, "YCOR:DASEL:423:BMIN")
  field(DOL6, "YCOR:DASEL:423:BMIN")
  field(LNK1, "YCOR:DASEL:423:BMAGX.HOPR")
  field(LNK2, "YCOR:DASEL:423:BMAGY.HOPR")
  field(LNK3, "YCOR:DASEL:423:BLEM.HOPR")
  field(LNK4, "YCOR:DASEL:423:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DASEL:423:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DASEL:423:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:423:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:423:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DASEL:423:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DASEL:423:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DASEL:423:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:423:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:423:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:423:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:423:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:423:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DASEL:423:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DASEL:423:EDES NPP MS")
  field(INPB, "YCOR:DASEL:423:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DASEL:821:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DASEL:821:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DASEL:821:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DASEL:821:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DASEL:821:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DASEL:821:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DASEL:821:EDES.PROC PP")
    field(LNK2, "YCOR:DASEL:821:EACT.PROC PP")
    field(LNK3, "YCOR:DASEL:821:EERR.DISA PP")
    field(LNK4, "YCOR:DASEL:821:ECON.PROC PP")
    field(LNK5, "YCOR:DASEL:821:BMAGX.PROC PP")
    field(LNK6, "YCOR:DASEL:821:BMAGY.PROC PP")
    field(LNK7, "YCOR:DASEL:821:BLEM.PROC PP")
    field(LNK8, "YCOR:DASEL:821:BMOD.PROC PP")
    field(LNK9, "YCOR:DASEL:821:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DASEL:821:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DASEL:821:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DASEL:821:BMAX")
  field(DOL2, "YCOR:DASEL:821:BMAX")
  field(DOL3, "YCOR:DASEL:821:BMAX")
  field(DOL4, "YCOR:DASEL:821:BMIN")
  field(DOL5, "YCOR:DASEL:821:BMIN")
  field(DOL6, "YCOR:DASEL:821:BMIN")
  field(LNK1, "YCOR:DASEL:821:BMAGX.HOPR")
  field(LNK2, "YCOR:DASEL:821:BMAGY.HOPR")
  field(LNK3, "YCOR:DASEL:821:BLEM.HOPR")
  field(LNK4, "YCOR:DASEL:821:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DASEL:821:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DASEL:821:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:821:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:821:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DASEL:821:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DASEL:821:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DASEL:821:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:821:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:821:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:821:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:821:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:821:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DASEL:821:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DASEL:821:EDES NPP MS")
  field(INPB, "YCOR:DASEL:821:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "YCOR:DASEL:999:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "YCOR:DASEL:999:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "YCOR:DASEL:999:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "YCOR:DASEL:999:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "YCOR:DASEL:999:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "YCOR:DASEL:999:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "YCOR:DASEL:999:EDES.PROC PP")
    field(LNK2, "YCOR:DASEL:999:EACT.PROC PP")
    field(LNK3, "YCOR:DASEL:999:EERR.DISA PP")
    field(LNK4, "YCOR:DASEL:999:ECON.PROC PP")
    field(LNK5, "YCOR:DASEL:999:BMAGX.PROC PP")
    field(LNK6, "YCOR:DASEL:999:BMAGY.PROC PP")
    field(LNK7, "YCOR:DASEL:999:BLEM.PROC PP")
    field(LNK8, "YCOR:DASEL:999:BMOD.PROC PP")
    field(LNK9, "YCOR:DASEL:999:EDESSAVE.PROC PP")
    field(LNKA, "YCOR:DASEL:999:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"YCOR:DASEL:999:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "YCOR:DASEL:999:BMAX")
  field(DOL2, "YCOR:DASEL:999:BMAX")
  field(DOL3, "YCOR:DASEL:999:BMAX")
  field(DOL4, "YCOR:DASEL:999:BMIN")
  field(DOL5, "YCOR:DASEL:999:BMIN")
  field(DOL6, "YCOR:DASEL:999:BMIN")
  field(LNK1, "YCOR:DASEL:999:BMAGX.HOPR")
  field(LNK2, "YCOR:DASEL:999:BMAGY.HOPR")
  field(LNK3, "YCOR:DASEL:999:BLEM.HOPR")
  field(LNK4, "YCOR:DASEL:999:BMAGX.LOPR PP")
  field(LNK5, "YCOR:DASEL:999:BMAGY.LOPR PP")
  field(LNK6, "YCOR:DASEL:999:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:999:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "YCOR:DASEL:999:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "YCOR:DASEL:999:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "YCOR:DASEL:999:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG-m")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "YCOR:DASEL:999:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:999:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:999:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:999:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "YCOR:DASEL:999:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "YCOR:DASEL:999:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "YCOR:DASEL:999:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "YCOR:DASEL:999:EDES NPP MS")
  field(INPB, "YCOR:DASEL:999:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "BEND:BSYA:1000:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "BEND:BSYA:1000:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "BEND:BSYA:1000:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "BEND:BSYA:1000:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "BEND:BSYA:1000:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "BEND:BSYA:1000:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "BEND:BSYA:1000:EDES.PROC PP")
    field(LNK2, "BEND:BSYA:1000:EACT.PROC PP")
    field(LNK3, "BEND:BSYA:1000:EERR.DISA PP")
    field(LNK4, "BEND:BSYA:1000:ECON.PROC PP")
    field(LNK5, "BEND:BSYA:1000:BMAGX.PROC PP")
    field(LNK6, "BEND:BSYA:1000:BMAGY.PROC PP")
    field(LNK7, "BEND:BSYA:1000:BLEM.PROC PP")
    field(LNK8, "BEND:BSYA:1000:BMOD.PROC PP")
    field(LNK9, "BEND:BSYA:1000:EDESSAVE.PROC PP")
    field(LNKA, "BEND:BSYA:1000:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"BEND:BSYA:1000:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "BEND:BSYA:1000:BMAX")
  field(DOL2, "BEND:BSYA:1000:BMAX")
  field(DOL3, "BEND:BSYA:1000:BMAX")
  field(DOL4, "BEND:BSYA:1000:BMIN")
  field(DOL5, "BEND:BSYA:1000:BMIN")
  field(DOL6, "BEND:BSYA:1000:BMIN")
  field(LNK1, "BEND:BSYA:1000:BMAGX.HOPR")
  field(LNK2, "BEND:BSYA:1000:BMAGY.HOPR")
  field(LNK3, "BEND:BSYA:1000:BLEM.HOPR")
  field(LNK4, "BEND:BSYA:1000:BMAGX.LOPR PP")
  field(LNK5, "BEND:BSYA:1000:BMAGY.LOPR PP")
  field(LNK6, "BEND:BSYA:1000:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "BEND:BSYA:1000:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "BEND:BSYA:1000:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "BEND:BSYA:1000:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "BEND:BSYA:1000:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "BEND:BSYA:1000:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BSYA:1000:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#  field(DOL,  "")
  field(OMSL, "supervisory")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BSYA:1000:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:BSYA:1000:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "BEND:BSYA:1000:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
#   field(DOL,  "")
  field(OMSL, "supervisory")
  field(FLNK, "BEND:BSYA:1000:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "BEND:BSYA:1000:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "BEND:BSYA:1000:EDES NPP MS")
  field(INPB, "BEND:BSYA:1000:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DASEL:115:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "KICK:DASEL:115:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DASEL:115:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DASEL:115:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DASEL:115:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DASEL:115:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DASEL:115:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DASEL:115:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DASEL:115:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DASEL:115:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DASEL:115:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DASEL:115:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DASEL:115:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DASEL:115:EDES.PROC PP")
    field(LNK2, "KICK:DASEL:115:EACT.PROC PP")
    field(LNK3, "KICK:DASEL:115:EERR.DISA PP")
    field(LNK4, "KICK:DASEL:115:ECON.PROC PP")
    field(LNK5, "KICK:DASEL:115:BMAGX.PROC PP")
    field(LNK6, "KICK:DASEL:115:BMAGY.PROC PP")
    field(LNK7, "KICK:DASEL:115:BLEM.PROC PP")
    field(LNK8, "KICK:DASEL:115:BMOD.PROC PP")
    field(LNK9, "KICK:DASEL:115:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DASEL:115:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DASEL:115:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DASEL:115:BMAX")
  field(DOL2, "KICK:DASEL:115:BMAX")
  field(DOL3, "KICK:DASEL:115:BMAX")
  field(DOL4, "KICK:DASEL:115:BMIN")
  field(DOL5, "KICK:DASEL:115:BMIN")
  field(DOL6, "KICK:DASEL:115:BMIN")
  field(LNK1, "KICK:DASEL:115:BMAGX.HOPR")
  field(LNK2, "KICK:DASEL:115:BMAGY.HOPR")
  field(LNK3, "KICK:DASEL:115:BLEM.HOPR")
  field(LNK4, "KICK:DASEL:115:BMAGX.LOPR PP")
  field(LNK5, "KICK:DASEL:115:BMAGY.LOPR PP")
  field(LNK6, "KICK:DASEL:115:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:115:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:115:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DASEL:115:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DASEL:115:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DASEL:115:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:115:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:DASEL:105:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:115:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:105:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:115:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:115:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:105:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:115:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DASEL:115:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DASEL:115:EDES NPP MS")
  field(INPB, "KICK:DASEL:115:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DASEL:122:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "KICK:DASEL:122:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DASEL:122:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DASEL:122:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DASEL:122:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DASEL:122:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DASEL:122:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DASEL:122:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DASEL:122:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DASEL:122:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DASEL:122:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DASEL:122:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DASEL:122:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DASEL:122:EDES.PROC PP")
    field(LNK2, "KICK:DASEL:122:EACT.PROC PP")
    field(LNK3, "KICK:DASEL:122:EERR.DISA PP")
    field(LNK4, "KICK:DASEL:122:ECON.PROC PP")
    field(LNK5, "KICK:DASEL:122:BMAGX.PROC PP")
    field(LNK6, "KICK:DASEL:122:BMAGY.PROC PP")
    field(LNK7, "KICK:DASEL:122:BLEM.PROC PP")
    field(LNK8, "KICK:DASEL:122:BMOD.PROC PP")
    field(LNK9, "KICK:DASEL:122:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DASEL:122:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DASEL:122:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DASEL:122:BMAX")
  field(DOL2, "KICK:DASEL:122:BMAX")
  field(DOL3, "KICK:DASEL:122:BMAX")
  field(DOL4, "KICK:DASEL:122:BMIN")
  field(DOL5, "KICK:DASEL:122:BMIN")
  field(DOL6, "KICK:DASEL:122:BMIN")
  field(LNK1, "KICK:DASEL:122:BMAGX.HOPR")
  field(LNK2, "KICK:DASEL:122:BMAGY.HOPR")
  field(LNK3, "KICK:DASEL:122:BLEM.HOPR")
  field(LNK4, "KICK:DASEL:122:BMAGX.LOPR PP")
  field(LNK5, "KICK:DASEL:122:BMAGY.LOPR PP")
  field(LNK6, "KICK:DASEL:122:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:122:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:122:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DASEL:122:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DASEL:122:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DASEL:122:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:122:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:DASEL:105:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:122:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:105:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:122:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:122:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:105:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:122:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DASEL:122:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DASEL:122:EDES NPP MS")
  field(INPB, "KICK:DASEL:122:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DASEL:110:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "KICK:DASEL:110:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DASEL:110:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DASEL:110:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DASEL:110:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DASEL:110:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DASEL:110:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DASEL:110:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DASEL:110:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DASEL:110:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DASEL:110:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DASEL:110:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DASEL:110:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DASEL:110:EDES.PROC PP")
    field(LNK2, "KICK:DASEL:110:EACT.PROC PP")
    field(LNK3, "KICK:DASEL:110:EERR.DISA PP")
    field(LNK4, "KICK:DASEL:110:ECON.PROC PP")
    field(LNK5, "KICK:DASEL:110:BMAGX.PROC PP")
    field(LNK6, "KICK:DASEL:110:BMAGY.PROC PP")
    field(LNK7, "KICK:DASEL:110:BLEM.PROC PP")
    field(LNK8, "KICK:DASEL:110:BMOD.PROC PP")
    field(LNK9, "KICK:DASEL:110:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DASEL:110:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DASEL:110:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DASEL:110:BMAX")
  field(DOL2, "KICK:DASEL:110:BMAX")
  field(DOL3, "KICK:DASEL:110:BMAX")
  field(DOL4, "KICK:DASEL:110:BMIN")
  field(DOL5, "KICK:DASEL:110:BMIN")
  field(DOL6, "KICK:DASEL:110:BMIN")
  field(LNK1, "KICK:DASEL:110:BMAGX.HOPR")
  field(LNK2, "KICK:DASEL:110:BMAGY.HOPR")
  field(LNK3, "KICK:DASEL:110:BLEM.HOPR")
  field(LNK4, "KICK:DASEL:110:BMAGX.LOPR PP")
  field(LNK5, "KICK:DASEL:110:BMAGY.LOPR PP")
  field(LNK6, "KICK:DASEL:110:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:110:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:110:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DASEL:110:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DASEL:110:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DASEL:110:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:110:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:DASEL:105:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:110:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:105:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:110:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:110:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:105:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:110:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DASEL:110:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DASEL:110:EDES NPP MS")
  field(INPB, "KICK:DASEL:110:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DASEL:120:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "KICK:DASEL:120:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DASEL:120:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DASEL:120:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DASEL:120:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DASEL:120:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DASEL:120:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DASEL:120:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DASEL:120:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DASEL:120:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DASEL:120:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DASEL:120:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DASEL:120:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DASEL:120:EDES.PROC PP")
    field(LNK2, "KICK:DASEL:120:EACT.PROC PP")
    field(LNK3, "KICK:DASEL:120:EERR.DISA PP")
    field(LNK4, "KICK:DASEL:120:ECON.PROC PP")
    field(LNK5, "KICK:DASEL:120:BMAGX.PROC PP")
    field(LNK6, "KICK:DASEL:120:BMAGY.PROC PP")
    field(LNK7, "KICK:DASEL:120:BLEM.PROC PP")
    field(LNK8, "KICK:DASEL:120:BMOD.PROC PP")
    field(LNK9, "KICK:DASEL:120:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DASEL:120:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DASEL:120:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DASEL:120:BMAX")
  field(DOL2, "KICK:DASEL:120:BMAX")
  field(DOL3, "KICK:DASEL:120:BMAX")
  field(DOL4, "KICK:DASEL:120:BMIN")
  field(DOL5, "KICK:DASEL:120:BMIN")
  field(DOL6, "KICK:DASEL:120:BMIN")
  field(LNK1, "KICK:DASEL:120:BMAGX.HOPR")
  field(LNK2, "KICK:DASEL:120:BMAGY.HOPR")
  field(LNK3, "KICK:DASEL:120:BLEM.HOPR")
  field(LNK4, "KICK:DASEL:120:BMAGX.LOPR PP")
  field(LNK5, "KICK:DASEL:120:BMAGY.LOPR PP")
  field(LNK6, "KICK:DASEL:120:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:120:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:120:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DASEL:120:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DASEL:120:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DASEL:120:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:120:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:DASEL:115:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:120:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:115:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:120:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:120:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:115:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:120:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DASEL:120:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DASEL:120:EDES NPP MS")
  field(INPB, "KICK:DASEL:120:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "KICK:DASEL:125:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "KICK:DASEL:125:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "KICK:DASEL:125:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "KICK:DASEL:125:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "KICK:DASEL:125:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "KICK:DASEL:125:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "KICK:DASEL:125:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "KICK:DASEL:125:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "KICK:DASEL:125:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "KICK:DASEL:125:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "KICK:DASEL:125:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "KICK:DASEL:125:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "KICK:DASEL:125:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "KICK:DASEL:125:EDES.PROC PP")
    field(LNK2, "KICK:DASEL:125:EACT.PROC PP")
    field(LNK3, "KICK:DASEL:125:EERR.DISA PP")
    field(LNK4, "KICK:DASEL:125:ECON.PROC PP")
    field(LNK5, "KICK:DASEL:125:BMAGX.PROC PP")
    field(LNK6, "KICK:DASEL:125:BMAGY.PROC PP")
    field(LNK7, "KICK:DASEL:125:BLEM.PROC PP")
    field(LNK8, "KICK:DASEL:125:BMOD.PROC PP")
    field(LNK9, "KICK:DASEL:125:EDESSAVE.PROC PP")
    field(LNKA, "KICK:DASEL:125:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"KICK:DASEL:125:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "KICK:DASEL:125:BMAX")
  field(DOL2, "KICK:DASEL:125:BMAX")
  field(DOL3, "KICK:DASEL:125:BMAX")
  field(DOL4, "KICK:DASEL:125:BMIN")
  field(DOL5, "KICK:DASEL:125:BMIN")
  field(DOL6, "KICK:DASEL:125:BMIN")
  field(LNK1, "KICK:DASEL:125:BMAGX.HOPR")
  field(LNK2, "KICK:DASEL:125:BMAGY.HOPR")
  field(LNK3, "KICK:DASEL:125:BLEM.HOPR")
  field(LNK4, "KICK:DASEL:125:BMAGX.LOPR PP")
  field(LNK5, "KICK:DASEL:125:BMAGY.LOPR PP")
  field(LNK6, "KICK:DASEL:125:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:125:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "KICK:DASEL:125:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "KICK:DASEL:125:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "KICK:DASEL:125:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "KICK:DASEL:125:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:125:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "KICK:DASEL:122:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:125:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:122:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:125:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "KICK:DASEL:125:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "KICK:DASEL:122:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "KICK:DASEL:125:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "KICK:DASEL:125:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "KICK:DASEL:125:EDES NPP MS")
  field(INPB, "KICK:DASEL:125:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:304:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:304:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:304:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:304:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:304:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:304:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:304:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:304:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:304:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:304:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:304:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:304:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:304:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:304:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:304:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:304:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:304:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:304:BMAX")
  field(DOL2, "QUAD:DASEL:304:BMAX")
  field(DOL3, "QUAD:DASEL:304:BMAX")
  field(DOL4, "QUAD:DASEL:304:BMIN")
  field(DOL5, "QUAD:DASEL:304:BMIN")
  field(DOL6, "QUAD:DASEL:304:BMIN")
  field(LNK1, "QUAD:DASEL:304:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:304:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:304:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:304:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:304:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:304:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:304:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:304:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:304:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:304:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:304:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:304:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DASEL:300:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:304:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:300:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:304:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:304:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:300:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:304:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:304:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:304:EDES NPP MS")
  field(INPB, "QUAD:DASEL:304:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:314:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:314:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:314:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:314:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:314:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:314:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:314:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:314:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:314:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:314:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:314:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:314:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:314:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:314:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:314:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:314:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:314:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:314:BMAX")
  field(DOL2, "QUAD:DASEL:314:BMAX")
  field(DOL3, "QUAD:DASEL:314:BMAX")
  field(DOL4, "QUAD:DASEL:314:BMIN")
  field(DOL5, "QUAD:DASEL:314:BMIN")
  field(DOL6, "QUAD:DASEL:314:BMIN")
  field(LNK1, "QUAD:DASEL:314:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:314:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:314:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:314:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:314:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:314:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:314:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:314:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:314:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:314:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:314:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:314:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DASEL:312:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:314:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:312:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:314:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:314:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:312:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:314:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:314:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:314:EDES NPP MS")
  field(INPB, "QUAD:DASEL:314:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:690:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:690:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:690:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:690:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:690:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:690:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:690:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:690:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:690:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:690:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:690:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:690:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:690:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:690:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:690:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:690:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:690:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:690:BMAX")
  field(DOL2, "QUAD:DASEL:690:BMAX")
  field(DOL3, "QUAD:DASEL:690:BMAX")
  field(DOL4, "QUAD:DASEL:690:BMIN")
  field(DOL5, "QUAD:DASEL:690:BMIN")
  field(DOL6, "QUAD:DASEL:690:BMIN")
  field(LNK1, "QUAD:DASEL:690:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:690:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:690:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:690:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:690:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:690:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:690:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:690:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:690:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:690:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:690:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:690:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DASEL:625:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:690:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:625:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:690:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:690:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:625:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:690:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:690:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:690:EDES NPP MS")
  field(INPB, "QUAD:DASEL:690:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:758:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:758:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:758:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:758:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:758:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:758:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:758:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:758:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:758:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:758:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:758:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:758:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:758:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:758:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:758:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:758:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:758:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:758:BMAX")
  field(DOL2, "QUAD:DASEL:758:BMAX")
  field(DOL3, "QUAD:DASEL:758:BMAX")
  field(DOL4, "QUAD:DASEL:758:BMIN")
  field(DOL5, "QUAD:DASEL:758:BMIN")
  field(DOL6, "QUAD:DASEL:758:BMIN")
  field(LNK1, "QUAD:DASEL:758:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:758:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:758:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:758:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:758:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:758:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:758:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:758:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:758:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:758:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:758:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:758:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DASEL:625:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:758:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:625:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:758:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:758:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:625:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:758:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:758:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:758:EDES NPP MS")
  field(INPB, "QUAD:DASEL:758:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}
#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBD("../../../dbd/mgntSoft.dbd")
#! DBDEND



record(seq, "QUAD:DASEL:882:ALLFUNCGO") {
  field(DESC, "All function go")
  field(SELL, "MGNT:DASEL:1:CTRLSWITCH")
  field(SELM, "Specified")
  field(DOL1, "MGNT:DASEL:1:CTRL.RVAL")
  field(LNK1, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL2, "MGNT:DASEL:1:BENDCTRL.RVAL")
  field(LNK2, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL3, "MGNT:DASEL:1:BTRMCTRL.RVAL")
  field(LNK3, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL4, "MGNT:DASEL:1:LGPSCTRL.RVAL")
  field(LNK4, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL5, "MGNT:DASEL:1:QUADCTRL.RVAL")
  field(LNK5, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL6, "MGNT:DASEL:1:XCORCTRL.RVAL")
  field(LNK6, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL7, "MGNT:DASEL:1:YCORCTRL.RVAL")
  field(LNK7, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL8, "MGNT:DASEL:1:SOLNCTRL.RVAL")
  field(LNK8, "QUAD:DASEL:882:FUNC CA PP")
  field(DOL9, "MGNT:DASEL:1:KICKCTRL.RVAL")
  field(LNK9, "QUAD:DASEL:882:FUNC CA PP")
  field(DOLA, "MGNT:DASEL:1:SEXTCTRL.RVAL")
  field(LNKA, "QUAD:DASEL:882:FUNC CA PP")
  field(DISV, "0")
  field(SDIS, "QUAD:DASEL:882:SELECT CPP")
}


#! Generated by VisualDCT v2.5
#! DBDSTART
#! DBDEND

# Initialize model pvs on boot
record(seq, "QUAD:DASEL:882:BMAGINIT") {
    field(DOL1, "1")
    field(DOL2, "1")
    field(DOL3, "0")
    field(DOL4, "1")
    field(DOL5, "1")
    field(DOL6, "1")
    field(DOL7, "1")
    field(DOL8, "1")
    field(DLY8, "1")
    field(DOL9, "1")
    field(DOLA, "1")
    field(LNK1, "QUAD:DASEL:882:EDES.PROC PP")
    field(LNK2, "QUAD:DASEL:882:EACT.PROC PP")
    field(LNK3, "QUAD:DASEL:882:EERR.DISA PP")
    field(LNK4, "QUAD:DASEL:882:ECON.PROC PP")
    field(LNK5, "QUAD:DASEL:882:BMAGX.PROC PP")
    field(LNK6, "QUAD:DASEL:882:BMAGY.PROC PP")
    field(LNK7, "QUAD:DASEL:882:BLEM.PROC PP")
    field(LNK8, "QUAD:DASEL:882:BMOD.PROC PP")
    field(LNK9, "QUAD:DASEL:882:EDESSAVE.PROC PP")
    field(LNKA, "QUAD:DASEL:882:BMAGLIMITS.PROC PP")
    field(PINI, "YES")
}

record(seq,"QUAD:DASEL:882:BMAGLIMITS") {
  field(DESC, "BMAG Limits")
  field(DOL1, "QUAD:DASEL:882:BMAX")
  field(DOL2, "QUAD:DASEL:882:BMAX")
  field(DOL3, "QUAD:DASEL:882:BMAX")
  field(DOL4, "QUAD:DASEL:882:BMIN")
  field(DOL5, "QUAD:DASEL:882:BMIN")
  field(DOL6, "QUAD:DASEL:882:BMIN")
  field(LNK1, "QUAD:DASEL:882:BMAGX.HOPR")
  field(LNK2, "QUAD:DASEL:882:BMAGY.HOPR")
  field(LNK3, "QUAD:DASEL:882:BLEM.HOPR")
  field(LNK4, "QUAD:DASEL:882:BMAGX.LOPR PP")
  field(LNK5, "QUAD:DASEL:882:BMAGY.LOPR PP")
  field(LNK6, "QUAD:DASEL:882:BLEM.LOPR PP")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:882:BMAGX") {
  field(DESC, "Calc Horiz B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# No EGU as per Henrik
record(ao, "QUAD:DASEL:882:BMAGY") {
  field(DESC, "Calc Vert B-field")
  field(DTYP, "Soft Channel")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# BLEM value can change when we change eh setting in LEM
# BMOD is always caluated using same formula
record(ao, "QUAD:DASEL:882:BLEM") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}
record(ao, "QUAD:DASEL:882:BMOD") {
  field(DESC, "Calc LEM B-field")
  field(DTYP, "Soft Channel")
  field(EGU,  "kG")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

# Beam Energy PVs
record(ao, "QUAD:DASEL:882:EDESSAVE") {
  field(DESC, "edes for save/load")
  field(DTYP, "Soft Channel")
  field(EGU,  "GeV/c)")
  field(HOPR, "50.0")
  field(DRVH, "50.0")
  field(PREC, "7")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:882:ECON") {
  field(DESC, "Energy Config")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "GeV/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
  field(DOL,  "QUAD:DASEL:880:ECON CP MS")
  field(OMSL, "closed_loop")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:882:EDES") {
  field(DESC, "Desired Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(HOPR, "50.0")
  field(EGU,  "GeV/c")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:880:EDES CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:882:EERR")
  info(autosaveFields,"VAL")
}

record(ao, "QUAD:DASEL:882:EACT") {
  field(DESC, "Actual Energy")
  field(DTYP, "Soft Channel")
  field(DRVH, "50.0")
  field(DRVL, "0.0")
  field(EGU, "Gev/c")
  field(HOPR, "50.0")
  field(LOPR, "0.0")
  field(PREC, "6")
   field(DOL,  "QUAD:DASEL:880:EACT CP MS")
  field(OMSL, "closed_loop")
  field(FLNK, "QUAD:DASEL:882:EERR")
  info(autosaveFields,"VAL")
}

# This is the error of EACT-EDES used by the LEM CUD
# The error is 0.5% of EDES, unless EDES=0 then
# the error is 0.
record(calc,  "QUAD:DASEL:882:EERR") {
  field(DESC, "LEM Error")
  field(CALC, "A?((B-A)/A):0")
  field(INPA, "QUAD:DASEL:882:EDES NPP MS")
  field(INPB, "QUAD:DASEL:882:EACT NPP MS")
  field(HIHI, "0.005")
  field(HIGH, "0.005")
  field(LOLO, "-0.005")
  field(LOW,  "-0.005")
  field(HHSV, "MAJOR")
  field(LLSV, "MAJOR")
  field(HSV,  "MAJOR")
  field(LSV,  "MAJOR")
  field(DISA, "1")
}